4665 Lampson Avenue
14501-11 Noise Study.docx
71 the potential to result in varying degrees of temporary ground vibration, depending on the specific construction activities and equipment used. Ground vibration levels associated with various types of construction equipment are summarized on Table 11-4. Based on the representative vibration levels presented for various construction equipment types, it is possible to estimate the potential Project construction vibration levels using the following vibration assessment methods defined by the FTA. To describe the human response (annoyance) associated with vibration impacts the FTA provides the following equation: PPVequip = PPVref x (25/D)1.5
TABLE 11-4: VIBRATION SOURCE LEVELS FOR CONSTRUCTION EQUIPMENT Equipment PPV (in/sec)
at 25 feet
Small bulldozer 0.003
Jackhammer 0.035
Loaded Trucks 0.076
Large bulldozer 0.089
Source: Federal Transit Administration, Transit Noise and Vibration Impact Assessment Manual Using the vibration source level of construction equipment provided on Table 11-4 and the construction vibration assessment methodology published by the FTA, it is possible to estimate the Project vibration impacts. Table 11-5 presents the expected Project related vibration levels at the nearby receiver locations. At distances ranging from 51 to 5,046 feet from the Project construction activities, construction vibration velocity levels are estimated to range from less than 0.01 to 0.03 in/sec PPV. Based on maximum acceptable continuous vibration threshold of
0.30 PPV (in/sec), the typical Project construction vibration levels will satisfy the building damage thresholds at all receiver locations. Therefore, the Project-related vibration impacts are considered less than significant during the construction activities at the Project site.
In addition, the typical construction vibration levels at the nearest sensitive receiver locations are unlikely to be sustained during the entire construction period but will occur rather only during the times that heavy construction equipment is operating adjacent to the Project site boundaries.
4665 Lampson Avenue
14501-11 Noise Study.docx
72 TABLE 11-5: PROJECT CONSTRUCTION VIBRATION LEVELS
Receiver
Location1
Distance
to Const.
Activity
(Feet)2
Typical Construction Vibration Levels
PPV (in/sec)3 Thresholds
PPV
(in/sec)4
Thresholds
Exceeded?5
Small
bulldozer
Jackhammer Loaded
Trucks
Large
Bulldozer
Highest
Vibration
Level
R1 173' 0.00 0.00 0.00 0.00 0.00 0.30 No
R2 91' 0.00 0.01 0.01 0.01 0.01 0.30 No
R3 51' 0.00 0.01 0.03 0.03 0.03 0.30 No
R4 5,046' 0.00 0.00 0.00 0.00 0.00 0.30 No 1
Construction receiver locations are shown on Exhibit 11-A. 2 Distance from receiver location to Project construction boundary. 3 Based on the Vibration Source Levels of Construction Equipment (Table 11-4). 4 FRTA Transit Noise and Vibration Impact Assessment, September 2018. 5 Does the peak vibration exceed the acceptable vibration thresholds? "PPV" = Peak Particle Velocity
4665 Lampson Avenue
14501-11 Noise Study.docx
73 12 ON-SITE AIRCRAFT NOISE IMPACTS
An on-site exterior aircraft noise impact analysis has been completed to determine the noise exposure levels that would result from adjacent JFTB Los Alamitos aircraft noise sources in the Project study area, and to identify potential noise abatement measures for the proposed Project that would achieve acceptable Project noise levels.
The JFTB Los Alamitos is located adjacent to, and northwest of the Project. Exhibit 3-B shows the Project site in relation to the airport’s projected noise level contour boundaries, as provided by the 2020 Noise Assessment for Los Alamitos Airfield, Joint Forces Training Base Los Alamitos (18).
As shown on Exhibit 12-A, the northwestern portion of the Project site would locate residential uses between the 60 and 65 dBA CNEL noise level contours of JFTB Los Alamitos. The compatibility criteria (16), shown on Exhibit 3-D, indicates residential land uses exposed to noise levels less than 60 dBA CNEL are “normally consistent”, less than 65 dBA CNEL are considered “conditionally consistent” which requires an acoustical analysis to ensure that the interior CNEL does not exceed 45 dBA CNEL. The ALEUP does not require any additional considerations for exterior locations exposed to noise levels below 70 dBA CNEL.
As discussed in Section 7.2.1, typical building construction will provide a Noise Reduction (NR) of approximately 12 dBA with "windows open" and a minimum 25 dBA noise reduction with "windows closed." Based on future JFTB Los Alamitos aircraft noise levels ranging from 60 to 65 dBA CNEL, interior noise levels would range from 35 dBA to 40 dBA CNEL. This noise level analysis shows that the 45 dBA CNEL interior noise standard can be satisfied using standard construction and complying with statutory and regulatory noise requirements for all residential units exposed to aircraft noise from JFTB Los Alamitos. Therefore, the Project would not expose people residing or working in the project area to excessive noise levels from airport or aircraft operations, and impacts would be less than significant.
4665 Lampson Avenue
14501-11 Noise Study.docx
74 EXHIBIT 12-A: ON-SITE AIRCRAFT NOISE LEVEL CONTOURS
4665 Lampson Avenue
14501-11 Noise Study.docx
75 13 REFERENCES
1. State of California. California Environmental Quality Act, Appendix G & Amendments and Additions to the State CEQA Guidelines. 2019.
2. U.S. Department of Transportation Federal Highway Administration. Acoustical Consideration. Noise Barrier Design Handbook. [Online] [Cited: November 28, 2016.] https://www.fhwa.dot.gov/environment/noise/noise_barriers/design_construction/design/design0
3.cfm.
3. U.S. Department of Transportation, Federal Highway Administration, Office of Environment and Planning, Noise and Air Quality Branch. Highway Traffic Noise Analysis and Abatement Policy and Guidance. December 2011.
4. California Department of Transportation. Traffic Noise Analysis Protocol. May 2011.
5. Harris, Cyril M. Noise Control in Buildings. s.l. : McGraw-Hill, Inc., 1994.
6. Urban Crossroads, Inc. 4665 Lampson Avenue Traffic Analysis. February 3, 2023.
7. U.S. Department of Transportation, Federal Transit Administration. Transit Noise and Vibration Impact Assessment Manual, FTA Report No. 0123. September 2018.
8. Environmental Protection Agency Office of Noise Abatement and Control. Information on Levels of Environmental Noise Requisite to Protect Public Health and Welfare with an Adequate Margin of Safety. March 1974. EPA/ONAC 550/9/74-004.
9. California Department of Transportation Environmental Program. Technical Noise Supplement - A Technical Supplement to the Traffic Noise Analysis Protocol. Sacramento, CA : s.n., September 2013.
10. U.S. Department of Transportation, Federal Highway Administration. Highway Traffic Noise in the United States, Problem and Response. April 2000. p. 3.
11. California Department of Transportation. Transportation and Construction Vibration Guidance Manual. April 2020.
12. Office of Planning and Research. State of California General Plan Guidlines 2003. October 2003.
13. State of California. 2019 California Green Building Standards Code. January 2020.
14. Alamitos, City of Los. Los Alamitos General Plan . March 23, 2015.
15. City of Los Alamitos. Municipal Code, Section 17.20.020.
16. Commision, Orange Count Airport Land Use. Airport Environs Land Use Plan (AELUP) for Joint Forces Training Base Los Alamitos. August 17, 2017.
17. Office of the Adjutant General California National Gaurd. Air Installation Compatible Use Zone (AICUZ) Study, Armed Forces Reserve Center Los Alamitos Airfield. March 1994.
18. U.S. Army Public Health Center. Noise Assessment for Los Alamitos Airfield, Joint Forces Trainig Base Los Alamitos. June 1, 2020.
19. California Court of Appeal. Gray v. County of Madera, F053661. 167 Cal.App.4th 1099; - Cal.Rptr.3d, October 2008.
20. Federal Interagency Committee on Noise. Federal Agency Review of Selected Airport Noise Analysis Issues. August 1992.
21. California Department of Transportation. Technical Noise Supplement. November 2009.
4665 Lampson Avenue
14501-11 Noise Study.docx
76 22. Urban Crossroads, Inc. The Lumberyard (DEV2020-00262). 2022.
23. U.S. Department of Transportation, Federal Highway Administration. FHWA Highway Traffic Noise Prediction Model. December 1978. FHWA-RD-77-108.
24. California Department of Transportation Environmental Program, Office of Environmental Engineering. Use of California Vehicle Noise Reference Energy Mean Emission Levels (Calveno REMELs) in FHWA Highway Traffic Noise Prediction. September 1995. TAN 95-03.
25. City of Seal Beach. City of Seal Beach General Plan Circulation Element. December 2003.
26. California Department of Transportation. Traffic Noise Attenuation as a Function of Ground and Vegetation Final Report. June 1995. FHWA/CA/TL-95/23.
27. U.S. Department of Transportation, Federal Highway Administration, Office of Environment and Planning. FHWA Roadway Construction Noise Model. January, 2006.
4665 Lampson Avenue
14501-11 Noise Study.docx
77 14 CERTIFICATION
The contents of this noise study report represent an accurate depiction of the noise environment and impacts associated with the proposed 4665 Lampson Avenue Project. The information contained in this noise study report is based on the best available data at the time of preparation.
If you have any questions, please contact me directly at (619) 788-1971.
William Maddux
Senior Associate
URBAN CROSSROADS, INC.
(619) 788-1971
[email protected]
EDUCATION
Bachelor of Science in Urban and Regional Planning
California Polytechnic State University, Pomona • June 2000
PROFESSIONAL AFFILIATIONS
ASA – Acoustical Society of America
APA – American Planning Association
AWMA – Air and Waste Management Association
PROFESSIONAL CERTIFICATIONS
Approved Acoustical Consultant • County of San Diego
FHWA Traffic Noise Model of Training • November 2004
CadnaA Basic and Advanced Training Certificate • October 2008.
4665 Lampson Avenue
14501-11 Noise Study.docx
78 This page intentionally left blank
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 3.1:
CITY OF LOS ALAMITOS MUNICIPAL CODE
79
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
80
Los Alamitos, California Municipal Code
Title 17 ZONING
Division 3: SITE PLANNING AND GENERAL DEVELOPMENT STANDARDS Chapter 17.20 NOISE
17.20.010 Purpose
17.20.020 Exemptions
17.20.030 Noise Level Measurement Criteria
17.20.040 Designated Noise Districts
17.20.050 Exterior Noise Standards
17.20.060 Interior Noise Standards
17.20.070 Special Provisions—Schools, Hospitals, and Places of Public Assembly
17.20.080 Manner of Enforcement
17.20.090 Relief from Standards—Application Procedure
17.20.010 Purpose
A. The City establishes the noise regulations in this chapter to control unnecessary, excessive, and annoying sounds emanating from all properties and land uses in the City. It is the declared policy of the City to prohibit these sounds generated from all sources, as specified in this chapter.
B. The City recognizes and declares, based on published scientific and health data, that certain noise levels are detrimental to the public health, welfare, and general safety and contrary to public interest.
Therefore, the Council does ordain and declare that creating, maintaining, causing, or allowing to create, maintain, or cause any noise in a manner prohibited by, or not in conformity with the provisions of this chapter, is a public nuisance and shall be abated and when such abated is not achieved, to be punishable as a public nuisance pursuant to Section 17.20.080 (Manner of Enforcement) of this title. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
17.20.020 Exemptions
The following activities shall be exempt from the provisions of this chapter.
Chapter 17.20 NOISE https://library.qcode.us/lib/los_alamitos_ca/pub/municipal_code/item/tit... 1 of 6 2/6/2023, 8:33 AM
81
A. School bands, school athletic events, and school entertainment events, provided these events are conducted on school property or authorized by special permit from the City; B. Activities lawfully conducted in public parks, public playgrounds, and public or private school grounds;
C. A mechanical device, apparatus, or equipment used, related to, or connected with emergency machinery, vehicle, or work;
D. Noise sources associated with construction, repair, remodeling, or grading of any real property, provided a permit has been obtained from the City, and further provided the activities do not take place between the hours of 8:00 p.m. and 7:00 a.m. on weekdays and on Saturdays, or at any time on Sundays or Federal holidays;
E. Noise sources associated with the maintenance of real property, provided the activities take place between the hours of 8:00 a.m. and 8:00 p.m. on weekdays and on Saturdays, or between the hours of 9:00 a.m. and 6:00 p.m. on Sunday or a Federal holiday; F. An activity or equipment to the extent that design regulation of it has been preempted by State or Federal laws. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
17.20.030 Noise Level Measurement Criteria
Noise level measurements made in compliance with the provisions of this chapter shall be performed using a sound level meter as defined in Division 7 (Definitions). The location selected for measuring exterior noise levels shall be at any point on the property line of the offender or anywhere on the affected property. Interior noise measurements shall be made within the affected building. The measurement shall be made at a point in the affected building at least four feet from the wall, ceiling, or floor nearest the noise source. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
17.20.040 Designated Noise Districts
A. Noise Districts. For the purposes of controlling noise and its impacts, the City shall be divided into noise districts defined as follows:
1. Noise District 1: All properties zoned R-1, R-2, R-3, and MH.
2. Noise District 2: All properties zoned C-O, C-F, and O-A, and with an MOZ overlay.
3. Noise District 3: All properties zoned C-G and TCMU, and with the ROZ overlay.
4. Noise District 4: All properties zoned P-L-I.
B. Unclassified. For any property or group of properties zoned SP, the Director shall assign an applicable noise district based upon the prevailing land uses within the specific plan area. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
Chapter 17.20 NOISE https://library.qcode.us/lib/los_alamitos_ca/pub/municipal_code/item/tit... 2 of 6 2/6/2023, 8:33 AM
82
17.20.050 Exterior Noise Standards
A. Baseline. The following noise standards, unless otherwise specifically indicated, shall apply to properties within the identified noise districts. No person shall cause any noise to occur that exceeds these standards except as authorized in subsection B, below.
Table 3-01: Exterior Noise Standards
Noise District Maximum Noise Level Time Period
1—Daytime 55 dB(A) 7:00 a.m. to 10:00 p.m.
1—Nighttime 50 dB(A) 10:00 p.m. to 7:00 a.m.
2 55 dB(A) Anytime
3 60 dB(A) Anytime
4 70 dB(A) Anytime
B. Temporary Exceedances. It is unlawful for any person to create noise, or to allow the creation of noise, on property owned, leased, occupied, or otherwise controlled by a person, that causes the baseline noise levels established in subsection A, either within or outside of the City, to exceed the applicable noise standard as follows:
1. For a cumulative period of more than 30 minutes in any hour;
2. Plus five dB(A) for a cumulative period of more than 15 minutes in any hour;
3. Plus 10 dB(A) for a cumulative period of more than five minutes in any hour;
4. Plus 15 dB(A) for a cumulative period of more than one minute in any hour; or
5. Plus 20 dB(A) for any period of time.
C. Maximum Allowable Noise Levels. In the event the ambient noise level exceeds the noise limit categories described in subsections (B)(1) through (5) of this section above, the cumulative period applicable to the category shall be increased to reflect the ambient noise level. In the event the ambient noise level exceeds the fifth noise limit category, the maximum allowable noise level under that category shall be increased to reflect the maximum ambient noise level. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
17.20.060 Interior Noise Standards
Chapter 17.20 NOISE https://library.qcode.us/lib/los_alamitos_ca/pub/municipal_code/item/tit... 3 of 6 2/6/2023, 8:33 AM
83
A. Baseline. Interior noise standards established by the State Health and Safety Code (California Code of Regulations, Title 24, Part 2) shall apply to all multi-family residential construction and uses. For all other uses, the following interior noise standards shall apply.
Table 3-02: Interior Noise Standards
Noise District Maximum Noise Level Time Period
1—Daytime 55 dB(A) 7:00 a.m. to 10:00 p.m.
1—Nighttime 45 dB(A) 10:00 p.m. to 7:00 a.m.
2, 3, 4 55 dB(A) Anytime
B. Temporary Exceedances. It is unlawful for any person to create noise, or to allow the creation of noise, on property owned, leased, occupied, or otherwise controlled by a person, that causes the noise level, when measured within structures in the applicable noise district, to exceed:
1. The noise standard for a cumulative period of more than five minutes in an hour;
2. The noise standard plus five dB(A) for a cumulative period of more than one minute in an hour; or
3. The noise standard plus ten 10 dB(A) for any period of time.
C. Maximum Allowable Noise Levels. In the event the ambient noise level exceeds either of the first two noise limit categories described in subsections (B)(1) and (2) of this section, the cumulative period applicable to the category shall be increased to reflect the ambient noise level. In the event the ambient noise level exceeds the third noise limit category, the maximum allowable noise level under that category shall be increased to reflect the maximum ambient noise level.
D. Different Noise Districts. In the event that the noise source and the affected property are within different noise districts, the noise standards of the affected property shall apply. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
17.20.070 Special Provisions—Schools, Hospitals, and Places of Public Assembly
It is unlawful for a person to create noise that causes the noise level at a school, hospital, or place of public assembly—while the facility is in use—to exceed the noise limits specified for exterior noise in this chapter, or which noise level unreasonably interferes with the use of the facility or which unreasonably disturbs or annoys patients in a hospital, provided conspicuous signs are displayed in three separate locations within one-tenth of a mile of the school, hospital, or place of public assembly indicating the presence of such school, hospital, or place of public assembly. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
Chapter 17.20 NOISE https://library.qcode.us/lib/los_alamitos_ca/pub/municipal_code/item/tit... 4 of 6 2/6/2023, 8:33 AM
84
17.20.080 Manner of Enforcement
A. The Director and duly authorized representatives are directed to enforce the provisions of this chapter. The Police Chief and duly authorized representatives are authorized in compliance with Penal Code Section 836.5 to arrest any person without a warrant when they have reasonable cause to believe that a person has committed a misdemeanor in their presence.
B. Persons shall not interfere with, oppose, or resist an authorized person charged with enforcement of this chapter while any person is engaged in the performance of his or her duty. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006)
17.20.090 Relief from Standards—Application Procedure
A. Application Requirements. The owner or operator of a noise source that violates any of the provisions of this chapter may file an application with the Director for relief from the provisions, and the owner or operator shall detail all actions taken to comply with the provisions, the reasons why immediate compliance cannot be achieved, a proposed method of achieving compliance, and a proposed time schedule for its accomplishment. The application shall be accompanied by a fee as established by resolution of the Council.
B. Separate Applications. A separate application shall be filed for each noise source. However, in the circumstance that several mobile sources are under common ownership, or several fixed sources occur on a single property, such request for relief may be combined into one application. Upon receipt of the application and fee, the Director shall refer it with his/her recommendation in compliance with the provisions of this chapter.
C. Compliance Required Until Relief Granted. An applicant for relief shall remain subject to prosecution under the terms of this title until such relief is granted.
D. Review Authority. The Planning Commission shall evaluate all applications for relief from the requirements of this chapter and may grant relief with respect to time for compliance subject to the terms, conditions, and requirements as it may deem reasonable to achieve maximum compliance with the provisions of this chapter. These terms, conditions, and requirements may include, but shall not be limited to, limitations on noise levels and operating hours. Each relief application granted shall identify in detail the approved method of achieving maximum compliance and a time schedule for its accomplishment.
E. Factors to Be Considered. In its determinations, the Planning Commission shall consider the magnitude of nuisance caused by the offensive noise; the uses of property within the area of impingement by the noise; the time factors related to study, design, financing and construction of remedial work; the economic factors related to age and useful life of equipment; and the general public interest and welfare.
Chapter 17.20 NOISE https://library.qcode.us/lib/los_alamitos_ca/pub/municipal_code/item/tit... 5 of 6 2/6/2023, 8:33 AM
85
F. Violations. Any relief granted shall be by resolution and shall be transmitted to the Director for enforcement. A violation of the terms of the relief is unlawful. (Ord. 19-03 § 3, 2019; Ord. 688 § 1, 2006) Contact:
City Clerk: 562-431-3538
Published by Quality Code Publishing, Seattle, WA. By using this site, you agree to the terms of use.
Chapter 17.20 NOISE https://library.qcode.us/lib/los_alamitos_ca/pub/municipal_code/item/tit... 6 of 6 2/6/2023, 8:33 AM
86
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 5.1:
STUDY AREA PHOTOS
87
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
88
JN: 14501 Study Area Photos
L1_E
33, 46' 57.570000"118, 2' 59.680000"
L1_N
33, 46' 57.590000"118, 2' 59.710000"
L1_S
33, 46' 57.590000"118, 2' 59.710000"
L1_W
33, 46' 57.580000"118, 2' 59.680000"
L2_E
33, 46' 53.210000"118, 2' 40.920000"
L2_N
33, 46' 53.270000"118, 2' 40.920000"
89
JN: 14501 Study Area Photos
L2_S
33, 46' 53.240000"118, 2' 40.920000"
L2_W
33, 46' 53.230000"118, 2' 40.920000"
L3_E
33, 46' 51.840000"118, 3' 10.150000"
L3_N
33, 46' 51.800000"118, 3' 10.310000"
L3_S
33, 46' 51.830000"118, 3' 10.280000"
L3_W
33, 46' 51.850000"118, 3' 10.120000"
90
JN: 14501 Study Area Photos
L4_E
33, 46' 53.010000"118, 4' 8.760000"
L4_N
33, 46' 52.980000"118, 4' 9.010000"
L4_S
33, 46' 52.990000"118, 4' 8.870000"
L4_W
33, 46' 53.010000"118, 4' 8.790000"
91
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
92
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 5.2:
NOISE LEVEL MEASUREMENTS
93
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
94
Date: Location: Meter: Piccolo II JN: 14501
Project: 4665 Lampson Source: Analyst: A. Khan
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 38.2 41.9 35.9 41.6 41.4 40.8 40.3 39.0 37.6 36.5 36.3 36.0 38.2 10.0 48.2 1 38.3 43.5 35.9 43.0 42.7 41.6 40.5 38.7 37.6 36.4 36.3 36.0 38.3 10.0 48.3 2 34.6 37.8 33.0 37.5 37.2 36.5 36.1 34.9 34.2 33.4 33.3 33.1 34.6 10.0 44.6 3 33.5 36.4 32.4 36.1 35.8 35.2 34.7 33.7 33.2 32.7 32.6 32.5 33.5 10.0 43.5 4 36.9 42.1 35.2 41.4 40.7 39.3 38.3 37.1 36.5 35.6 35.5 35.3 36.9 10.0 46.9 5 44.7 51.5 38.9 51.0 50.4 49.2 48.2 45.8 43.2 40.2 39.6 39.1 44.7 10.0 54.7 6 47.8 53.7 43.0 53.3 53.0 51.9 51.5 48.6 46.3 44.0 43.6 43.2 47.8 10.0 57.8 7 46.7 52.9 42.4 52.4 52.0 51.0 50.2 47.6 45.4 43.1 42.8 42.5 46.7 0.0 46.7 8 47.8 56.1 42.5 55.0 54.3 52.8 51.7 48.2 45.6 43.3 43.0 42.7 47.8 0.0 47.8 9 49.5 57.2 45.5 56.5 55.6 54.0 52.9 49.7 48.0 46.1 45.9 45.6 49.5 0.0 49.5 10 49.7 54.4 46.5 54.0 53.7 53.1 52.6 50.3 48.9 47.1 46.9 46.6 49.7 0.0 49.7 11 49.4 53.7 46.7 53.4 53.1 52.4 51.9 50.2 48.6 47.2 47.0 46.8 49.4 0.0 49.4 12 50.5 69.7 48.9 68.2 67.1 63.6 61.9 57.3 53.8 50.2 49.8 49.3 50.5 0.0 50.5 13 49.0 55.5 44.7 55.1 54.6 53.2 52.3 49.9 47.4 45.4 45.1 44.8 49.0 0.0 49.0 14 49.8 56.5 46.1 55.9 55.3 54.0 53.1 50.3 48.4 46.7 46.5 46.2 49.8 0.0 49.8 15 51.6 57.7 46.6 57.3 56.8 55.9 55.2 52.8 49.5 47.2 47.0 46.7 51.6 0.0 51.6 16 50.6 55.3 47.5 55.0 54.5 53.7 53.1 51.3 49.8 48.1 47.9 47.6 50.6 0.0 50.6 17 51.7 57.4 47.8 57.1 56.6 55.8 55.2 52.6 50.2 48.5 48.2 47.9 51.7 0.0 51.7 18 50.8 56.4 47.5 56.0 55.7 55.0 54.2 51.5 49.4 48.0 47.8 47.6 50.8 0.0 50.8 19 50.3 54.9 47.1 54.6 54.3 53.6 53.1 51.3 49.1 47.6 47.4 47.2 50.3 5.0 55.3 20 51.1 57.4 45.1 57.1 56.9 56.5 55.9 51.9 48.8 45.8 45.5 45.2 51.1 5.0 56.1 21 46.5 51.8 42.2 51.4 51.1 50.3 49.7 47.6 45.3 42.9 42.6 42.4 46.5 5.0 51.5 22 44.0 49.3 40.3 48.9 48.5 47.8 47.2 44.9 42.5 40.8 40.6 40.4 44.0 10.0 54.0 23 42.6 47.6 38.6 47.3 47.0 46.4 46.0 44.0 40.8 39.1 38.9 38.7 42.6 10.0 52.6 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 46.5 51.8 42.2 51.4 51.1 50.3 49.7 47.6 45.3 42.9 42.6 42.4 Max 51.7 69.7 48.9 68.2 67.1 63.6 61.9 57.3 53.8 50.2 49.8 49.3
49.9 55.9 55.4 54.3 53.5 50.8 48.5 46.5 46.2 45.9
Min 33.5 36.4 32.4 36.1 35.8 35.2 34.7 33.7 33.2 32.7 32.6 32.5 Max 47.8 53.7 43.0 53.3 53.0 51.9 51.5 48.6 46.3 44.0 43.6 43.2
42.4 44.5 44.1 43.2 42.5 40.7 39.1 37.6 37.4 37.1
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
L eq (dBA)
Night
Monday, May 23, 2022 L1 - Located north of the Project site near Arbor Dog Park at 4665 Lampson Avenue.
Night
Day
Day
Night
Energy Average
Energy Average Average:
Average:
24-Hour Daytime
(7am-10pm)
Nighttime
(10pm-7am)
48.3 49.9 42.4
38.238.334.633.536.9
44.7 47.8
46.7 47.8
49.5 49.7
49.4 50.5
49.0 49.8
51.6 50.6
51.7 50.8
50.3 51.1
46.5 44.0
42.6 25.0
30.0 35.0
40.0 45.0
50.0 55.0
60.0 65.0
70.0 75.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14100-14500\_14500\14501\04_Noise\Fieldwork\Measurement\14501_L1_T 95
Date: Location: Meter: Piccolo II JN: 14501
Project: 4665 Lampson Source: Analyst: A. Khan
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 46.5 56.8 40.3 56.5 56.0 53.7 50.9 44.4 42.2 40.9 40.7 40.4 46.5 10.0 56.5 1 47.3 58.0 40.7 57.8 57.1 55.0 51.8 44.7 43.0 41.4 41.1 40.8 47.3 10.0 57.3 2 43.8 54.9 36.1 54.5 54.0 51.5 48.6 40.9 37.9 36.6 36.4 36.2 43.8 10.0 53.8 3 41.4 52.5 34.8 52.1 51.6 49.3 46.3 37.7 36.0 35.2 35.0 34.8 41.4 10.0 51.4 4 47.3 58.8 36.9 58.4 57.8 55.2 52.8 43.8 39.2 37.2 37.1 36.9 47.3 10.0 57.3 5 57.5 65.6 45.8 65.3 64.9 63.5 62.3 58.9 54.6 48.6 47.6 46.1 57.5 10.0 67.5 6 57.2 66.5 47.6 66.2 65.6 63.6 62.1 57.2 53.3 48.7 48.2 47.7 57.2 10.0 67.2 7 62.2 73.6 48.8 73.2 72.5 69.2 66.6 61.1 56.9 50.6 49.6 48.9 62.2 0.0 62.2 8 61.1 71.2 49.8 70.6 69.9 67.5 65.6 61.0 57.7 51.5 50.6 50.0 61.1 0.0 61.1 9 59.0 68.2 49.5 67.7 67.0 65.1 63.6 59.5 55.6 50.5 50.0 49.6 59.0 0.0 59.0 10 58.9 66.8 51.3 66.6 66.1 64.2 63.0 59.7 56.5 52.4 51.8 51.4 58.9 0.0 58.9 11 64.2 77.3 52.1 76.9 75.7 71.4 67.6 61.0 57.3 53.1 52.6 52.2 64.2 0.0 64.2 12 61.2 72.4 52.5 71.2 69.9 67.7 66.4 62.1 58.9 54.5 53.5 52.8 61.2 0.0 61.2 13 61.9 72.9 48.8 72.3 71.7 69.1 66.6 60.6 56.4 50.3 49.6 49.0 61.9 0.0 61.9 14 60.3 69.6 50.3 69.0 68.2 66.3 64.4 60.8 57.7 52.2 51.1 50.5 60.3 0.0 60.3 15 61.4 70.7 51.1 70.2 69.5 67.5 65.9 61.5 58.4 52.6 51.8 51.2 61.4 0.0 61.4 16 60.2 67.8 52.6 67.5 66.9 65.3 64.0 61.1 58.4 54.0 53.4 52.8 60.2 0.0 60.2 17 60.5 67.9 53.0 67.5 67.0 65.2 64.1 61.4 58.9 54.5 53.8 53.2 60.5 0.0 60.5 18 61.2 71.0 53.3 70.4 69.8 67.0 64.7 61.1 58.3 54.5 54.0 53.4 61.2 0.0 61.2 19 59.3 66.3 53.7 66.0 65.5 64.1 63.0 60.2 57.6 54.6 54.2 53.8 59.3 5.0 64.3 20 58.5 66.8 51.9 66.4 65.7 63.8 62.4 59.1 55.9 52.9 52.4 52.0 58.5 5.0 63.5 21 55.6 63.3 49.0 63.0 62.5 61.1 60.0 56.3 53.0 49.8 49.4 49.1 55.6 5.0 60.6 22 52.8 61.9 45.8 61.5 61.1 59.0 57.5 52.8 49.1 46.4 46.1 45.9 52.8 10.0 62.8 23 49.7 59.2 43.2 58.9 58.4 56.2 54.3 48.9 45.9 43.8 43.6 43.3 49.7 10.0 59.7 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 55.6 63.3 48.8 63.0 62.5 61.1 60.0 56.3 53.0 49.8 49.4 48.9 Max 64.2 77.3 53.7 76.9 75.7 71.4 67.6 62.1 58.9 54.6 54.2 53.8
60.8 69.2 68.5 66.3 64.5 60.4 57.2 52.5 51.9 51.3
Min 41.4 52.5 34.8 52.1 51.6 49.3 46.3 37.7 36.0 35.2 35.0 34.8 Max 57.5 66.5 47.6 66.2 65.6 63.6 62.3 58.9 54.6 48.7 48.2 47.7
52.4 59.0 58.5 56.3 54.1 47.7 44.6 42.1 41.7 41.3
Day
Night
Energy Average
Energy Average Average:
Average:
24-Hour Daytime
(7am-10pm)
Nighttime
(10pm-7am)
59.1 60.8 52.4
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
L eq (dBA)
Night
Monday, May 23, 2022 L2 - Located east of the Project site near single-family residence at 5001 Lunar Drive.
Night
Day
46.547.343.841.447.3
57.5 57.2
62.2 61.1
59.0 58.9
64.2 61.2
61.9 60.3
61.4 60.2
60.5 61.2
59.3 58.5
55.6 52.8
49.7 35.0
40.0 45.0
50.0 55.0
60.0 65.0
70.0 75.0
80.0 85.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14100-14500\_14500\14501\04_Noise\Fieldwork\Measurement\14501_L2_V 96
Date: Location: Meter: Piccolo II JN: 14501
Project: 4665 Lampson Source: Analyst: A. Khan
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 55.3 68.3 43.2 67.9 66.9 63.4 60.1 48.4 44.8 43.5 43.4 43.2 55.3 10.0 65.3 1 52.3 65.0 43.2 64.5 63.7 60.5 57.0 46.1 44.6 43.6 43.4 43.3 52.3 10.0 62.3 2 52.5 65.7 38.6 65.3 64.3 60.5 57.1 45.1 40.4 39.0 38.9 38.7 52.5 10.0 62.5 3 51.3 64.6 38.4 64.2 63.2 59.8 56.0 42.7 39.4 38.6 38.5 38.4 51.3 10.0 61.3 4 54.3 67.2 39.4 66.7 65.8 62.4 59.4 48.5 42.1 39.8 39.7 39.5 54.3 10.0 64.3 5 65.5 77.0 48.8 76.6 75.8 73.1 70.8 63.5 58.0 50.3 49.5 49.0 65.5 10.0 75.5 6 65.7 76.6 53.4 76.0 75.0 72.1 70.5 65.4 60.5 55.1 54.3 53.6 65.7 10.0 75.7 7 69.0 78.6 53.1 78.1 77.4 75.3 74.1 69.4 64.9 56.5 54.8 53.3 69.0 0.0 69.0 8 69.1 78.6 53.0 78.2 77.5 75.6 74.2 69.6 64.4 55.8 54.4 53.3 69.1 0.0 69.1 9 67.6 77.2 52.1 76.8 76.1 74.2 72.8 67.9 62.9 54.0 52.9 52.2 67.6 0.0 67.6 10 66.5 76.1 52.9 75.6 74.8 72.9 71.5 67.0 62.0 54.6 53.8 53.1 66.5 0.0 66.5 11 66.4 76.3 52.4 75.9 75.1 72.7 71.2 66.9 61.7 54.0 53.2 52.5 66.4 0.0 66.4 12 66.1 75.5 53.8 74.9 74.1 72.2 71.2 66.6 62.2 55.8 54.9 54.0 66.1 0.0 66.1 13 71.7 84.6 51.7 83.7 82.2 79.3 76.9 69.4 63.7 54.1 52.9 51.9 71.7 0.0 71.7 14 68.8 77.9 53.2 77.4 76.6 74.8 73.6 69.7 65.1 56.3 54.8 53.5 68.8 0.0 68.8 15 71.1 82.3 53.7 81.5 80.6 77.8 75.9 70.7 65.9 56.9 55.5 54.0 71.1 0.0 71.1 16 69.0 78.4 53.8 77.9 77.3 75.3 73.8 69.5 65.0 56.7 55.2 54.0 69.0 0.0 69.0 17 68.7 77.8 53.7 77.4 76.7 74.7 73.4 69.6 64.8 56.2 55.2 54.0 68.7 0.0 68.7 18 68.5 77.0 53.1 76.6 75.9 74.6 73.7 69.7 64.1 55.5 54.3 53.2 68.5 0.0 68.5 19 67.6 77.0 53.2 76.4 75.8 73.9 72.9 68.5 62.5 54.8 53.9 53.3 67.6 5.0 72.6 20 70.3 84.0 51.9 83.1 81.6 76.7 73.7 67.9 62.0 53.7 52.5 52.0 70.3 5.0 75.3 21 64.1 74.7 48.9 74.2 73.4 71.4 69.9 63.4 57.1 50.4 49.8 49.1 64.1 5.0 69.1 22 62.2 73.9 46.5 73.4 72.5 69.7 67.9 60.2 52.3 47.2 46.9 46.6 62.2 10.0 72.2 23 58.2 70.9 44.5 70.4 69.4 66.1 63.1 54.2 48.4 45.0 44.8 44.6 58.2 10.0 68.2 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 64.1 74.7 48.9 74.2 73.4 71.4 69.9 63.4 57.1 50.4 49.8 49.1 Max 71.7 84.6 53.8 83.7 82.2 79.3 76.9 70.7 65.9 56.9 55.5 54.0
68.7 77.8 77.0 74.8 73.3 68.4 63.2 55.0 53.9 52.9
Min 51.3 64.6 38.4 64.2 63.2 59.8 56.0 42.7 39.4 38.6 38.5 38.4 Max 65.7 77.0 53.4 76.6 75.8 73.1 70.8 65.4 60.5 55.1 54.3 53.6
60.7 69.4 68.5 65.3 62.4 52.7 47.8 44.7 44.4 44.1
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
L eq (dBA)
Night
Monday, May 23, 2022 L3 - Located southwest of the Project site near single-family residence at 4701 Ironwood Avenue.
Night
Day
Day
Night
Energy Average
Energy Average Average:
Average:
24-Hour Daytime
(7am-10pm)
Nighttime
(10pm-7am)
67.0 68.7 60.7
55.3 52.352.551.3
54.3 65.5
65.7 69.0
69.1 67.6
66.5 66.4
66.1 71.7
68.8 71.1
69.0 68.7
68.5 67.6
70.3 64.1
62.2 58.2
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14100-14500\_14500\14501\04_Noise\Fieldwork\Measurement\14501_L3_M 97
Date: Location: Meter: Piccolo II JN: 14501
Project: 4665 Lampson Source: Analyst: A. Khan
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 53.6 59.0 49.7 58.7 58.5 57.8 57.1 54.9 51.8 50.3 49.9 49.8 53.6 10.0 63.6 1 47.8 51.0 45.7 50.7 50.4 49.9 49.4 48.3 47.5 46.3 46.1 45.9 47.8 10.0 57.8 2 46.9 50.5 44.7 50.1 49.5 48.8 48.4 47.5 46.7 45.4 45.2 44.9 46.9 10.0 56.9 3 55.6 65.8 44.1 65.3 64.4 62.4 61.0 54.9 51.5 44.8 44.5 44.2 55.6 10.0 65.6 4 59.4 69.3 46.1 68.7 68.2 66.8 65.4 58.7 52.6 47.1 46.5 46.3 59.4 10.0 69.4 5 56.5 67.3 51.7 66.6 65.3 62.3 59.4 55.9 53.3 52.1 52.0 51.8 56.5 10.0 66.5 6 55.2 63.9 50.7 62.9 61.8 60.1 58.0 55.2 53.5 51.6 51.2 50.8 55.2 10.0 65.2 7 55.4 66.7 47.4 65.8 64.3 61.1 59.8 54.7 51.0 48.2 47.9 47.6 55.4 0.0 55.4 8 58.7 69.4 49.0 69.0 68.4 66.2 63.9 56.8 52.9 50.1 49.6 49.2 58.7 0.0 58.7 9 58.0 66.1 54.4 65.6 65.0 63.4 61.7 57.5 55.9 54.8 54.7 54.5 58.0 0.0 58.0 10 57.5 68.6 51.7 67.5 66.1 63.2 61.1 56.7 54.3 52.3 52.1 51.8 57.5 0.0 57.5 11 54.8 62.9 51.6 62.1 61.3 59.3 57.8 54.7 53.2 52.1 51.9 51.7 54.8 0.0 54.8 12 60.0 69.6 52.7 68.9 67.9 66.1 64.1 59.4 57.7 54.2 53.7 53.1 60.0 0.0 60.0 13 56.5 67.3 49.6 66.4 65.4 62.3 60.1 56.0 53.7 50.4 50.0 49.7 56.5 0.0 56.5 14 51.7 58.9 49.1 58.1 57.2 55.3 53.9 51.7 50.6 49.6 49.4 49.2 51.7 0.0 51.7 15 54.3 59.8 50.5 59.5 59.1 58.2 57.5 55.2 52.8 51.0 50.8 50.6 54.3 0.0 54.3 16 53.9 60.6 51.3 60.1 59.6 57.5 56.0 54.0 52.9 51.9 51.6 51.4 53.9 0.0 53.9 17 54.6 59.5 52.0 59.0 58.7 57.9 57.0 54.9 53.7 52.5 52.3 52.1 54.6 0.0 54.6 18 55.3 62.1 52.4 61.8 61.6 59.9 58.4 54.9 53.8 52.9 52.7 52.5 55.3 0.0 55.3 19 56.1 63.0 53.1 62.6 61.9 60.3 59.0 56.2 54.7 53.7 53.5 53.2 56.1 5.0 61.1 20 56.1 63.5 52.1 63.2 62.7 61.3 59.7 56.0 54.5 52.8 52.5 52.2 56.1 5.0 61.1 21 57.7 65.3 52.1 65.0 64.4 62.7 61.1 58.4 56.1 52.7 52.5 52.2 57.7 5.0 62.7 22 55.2 59.8 52.8 59.5 59.1 58.5 58.1 55.8 54.1 53.1 53.0 52.8 55.2 10.0 65.2 23 53.2 61.8 48.5 60.9 59.8 57.5 56.0 53.3 51.4 50.0 49.7 48.7 53.2 10.0 63.2 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 51.7 58.9 47.4 58.1 57.2 55.3 53.9 51.7 50.6 48.2 47.9 47.6 Max 60.0 69.6 54.4 69.0 68.4 66.2 64.1 59.4 57.7 54.8 54.7 54.5
56.5 63.6 62.9 61.0 59.4 55.8 53.9 51.9 51.7 51.4
Min 46.9 50.5 44.1 50.1 49.5 48.8 48.4 47.5 46.7 44.8 44.5 44.2 Max 59.4 69.3 52.8 68.7 68.2 66.8 65.4 58.7 54.1 53.1 53.0 52.8
55.1 60.4 59.7 58.2 57.0 53.8 51.4 49.0 48.7 48.3
Day
Night
Energy Average
Energy Average Average:
Average:
24-Hour Daytime
(7am-10pm)
Nighttime
(10pm-7am)
56.0 56.5 55.1
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
L eq (dBA)
Night
Monday, May 23, 2022 L4 - Located west of the Project site near Old Ranch Country Club Golf Course at 3901 Lampson Avenue.
Night
Day
53.6 47.846.9
55.6 59.4
56.5 55.2
55.4 58.7
58.0 57.5
54.8 60.0
56.5 51.7
54.3 53.9
54.6 55.3
56.1 56.1
57.7 55.2
53.2 35.0
40.0 45.0
50.0 55.0
60.0 65.0
70.0 75.0
80.0 85.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14100-14500\_14500\14501\04_Noise\Fieldwork\Measurement\14501_L4_Z 98
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 6.1:
SITE PLAN
99
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
100
101
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
102
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 7.1:
ON-SITE TRAFFIC NOISE LEVEL CALCULATIONS
103
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
104
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Apartments Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Backyard No Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 57.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
4.27 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 5.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 4.36 -1.20 0.000 0.000
-21.34 4.36 -1.20 0.000 0.000
-1.67
-2.01
-2.96
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
25.534
25.185
25.220
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.3 70.4 68.6 62.6 71.2 71.8
63.4 64.0
61.9 55.5 54.0 62.4 62.7
62.5 53.5 54.7 63.1 63.2
Vehicle Noise: 73.3 71.5 68.9 63.7 72.3 72.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.3 70.4 68.6 62.6 71.2 71.8
63.4 64.0
61.9 55.5 54.0 62.4 62.7
62.5 53.5 54.7 63.1 63.2
Vehicle Noise: 73.3 71.5 68.9 63.7 72.3 72.8
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
105
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Single Family Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Backyard No Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 57.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
4.27 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 5.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 4.36 -1.20 0.000 0.000
-21.34 4.36 -1.20 0.000 0.000
-1.67
-2.01
-2.96
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
25.534
25.185
25.220
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.3 70.4 68.6 62.6 71.2 71.8
63.4 64.0
61.9 55.5 54.0 62.4 62.7
62.5 53.5 54.7 63.1 63.2
Vehicle Noise: 73.3 71.5 68.9 63.7 72.3 72.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.3 70.4 68.6 62.6 71.2 71.8
63.4 64.0
61.9 55.5 54.0 62.4 62.7
62.5 53.5 54.7 63.1 63.2
Vehicle Noise: 73.3 71.5 68.9 63.7 72.3 72.8
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
106
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Park Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Backyard No Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 120.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-4.24
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 68.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 -4.23 -1.20 0.000 0.000
-21.34 -4.24 -1.20 0.000 0.000
-0.05
-0.23
-1.20
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
94.366
94.273
94.282
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.8 61.9 60.1 54.0 62.7 63.3
54.8 55.4
53.3 46.9 45.4 53.8 54.1
53.9 44.9 46.2 54.5 54.6
Vehicle Noise: 64.8 63.0 60.4 55.2 63.7 64.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.8 61.9 60.1 54.0 62.7 63.3
54.8 55.4
53.3 46.9 45.4 53.8 54.1
53.9 44.9 46.2 54.5 54.6
Vehicle Noise: 64.8 63.0 60.4 55.2 63.7 64.3
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
107
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Apartments Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Backyard With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 57.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
4.75 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 5.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-7.700 -10.700
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 4.91 -1.20 -6.940 -9.940
-21.34 4.99 -1.20 -5.300 -8.300
0.34 0.22
0.03 Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
23.754
23.147
22.876
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.7 70.8 69.1 63.0 71.6 72.3
64.0 64.6
62.4 56.1 54.5 63.0 63.2
63.2 54.1 55.4 63.7 63.9
Vehicle Noise: 73.8 72.0 69.4 64.2 72.8 73.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
65.0 63.1 61.4 55.3 63.9 64.6
57.0 59.3
55.5 49.1 47.6 56.1 56.3
57.9 48.8 50.1 58.4 58.6
Vehicle Noise: 66.6 64.8 61.9 57.0 65.5 66.0
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
108
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Single Family Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Backyard With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 57.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
4.75 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 5.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-7.700 -10.700
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 4.91 -1.20 -6.940 -9.940
-21.34 4.99 -1.20 -5.300 -8.300
0.34 0.22
0.03 Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
23.754
23.147
22.876
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.7 70.8 69.1 63.0 71.6 72.3
64.0 64.6
62.4 56.1 54.5 63.0 63.2
63.2 54.1 55.4 63.7 63.9
Vehicle Noise: 73.8 72.0 69.4 64.2 72.8 73.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
65.0 63.1 61.4 55.3 63.9 64.6
57.0 59.3
55.5 49.1 47.6 56.1 56.3
57.9 48.8 50.1 58.4 58.6
Vehicle Noise: 66.6 64.8 61.9 57.0 65.5 66.0
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
109
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Park Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Backyard With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 120.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-3.69
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 68.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-8.400 -11.400
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 -3.64 -1.20 -6.800 -9.800
-21.34 -4.24 -1.20 0.000 0.000
0.48 0.20
-0.03
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
86.662
86.055
94.282
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.3 62.4 60.6 54.6 63.2 63.8
55.4 55.4
53.9 47.5 46.0 54.4 54.7
53.9 44.9 46.2 54.5 54.6
Vehicle Noise: 65.3 63.5 61.0 55.7 64.2 64.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
55.9 54.0 52.2 46.2 54.8 55.4
48.6 55.4
47.1 40.7 39.2 47.6 47.9
53.9 44.9 46.2 54.5 54.6
Vehicle Noise: 59.1 57.4 53.2 49.6 58.1 58.5
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
110
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Apartments Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: First Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
3.98 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-7.650 -10.650
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 4.13 -1.20 -6.720 -9.720
-21.34 4.20 -1.20 -5.100 -8.100
0.33 0.19
0.01 Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
26.717
26.110
25.839
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.0 70.1 68.3 62.3 70.9 71.5
63.2 63.8
61.7 55.3 53.8 62.2 62.4
62.4 53.3 54.6 62.9 63.1
Vehicle Noise: 73.1 71.3 68.7 63.4 72.0 72.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.3 62.4 60.7 54.6 63.2 63.8
56.4 58.7
54.9 48.6 47.0 55.5 55.7
57.3 48.2 49.5 57.8 58.0
Vehicle Noise: 65.9 64.1 61.2 56.3 64.9 65.3
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
111
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Single Family Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: First Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
3.98 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-7.650 -10.650
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 4.13 -1.20 -6.720 -9.720
-21.34 4.20 -1.20 -5.100 -8.100
0.33 0.19
0.01 Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
26.717
26.110
25.839
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.0 70.1 68.3 62.3 70.9 71.5
63.2 63.8
61.7 55.3 53.8 62.2 62.4
62.4 53.3 54.6 62.9 63.1
Vehicle Noise: 73.1 71.3 68.7 63.4 72.0 72.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.3 62.4 60.7 54.6 63.2 63.8
56.4 58.7
54.9 48.6 47.0 55.5 55.7
57.3 48.2 49.5 57.8 58.0
Vehicle Noise: 65.9 64.1 61.2 56.3 64.9 65.3
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
112
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Park Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: First Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 120.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-3.69
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 68.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-8.400 -11.400
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 -3.64 -1.20 -6.800 -9.800
-21.34 -4.24 -1.20 0.000 0.000
0.48 0.20
-0.03
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
86.662
86.055
94.282
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.3 62.4 60.6 54.6 63.2 63.8
55.4 55.4
53.9 47.5 46.0 54.4 54.7
53.9 44.9 46.2 54.5 54.6
Vehicle Noise: 65.3 63.5 61.0 55.7 64.2 64.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
55.9 54.0 52.2 46.2 54.8 55.4
48.6 55.4
47.1 40.7 39.2 47.6 47.9
53.9 44.9 46.2 54.5 54.6
Vehicle Noise: 59.1 57.4 53.2 49.6 58.1 58.5
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
113
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Apartments Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Fourth Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
0.85 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 1.11 -1.20 0.000 0.000
-21.34 1.75 -1.20 0.000 0.000
-7.73
-8.80
-11.91
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
43.174
41.500
37.626
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.0 65.2 59.1 67.8 68.4
60.1 61.3
58.6 52.3 50.7 59.2 59.4
59.9 50.9 52.1 60.5 60.6
Vehicle Noise: 70.0 68.2 65.6 60.4 69.0 69.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.0 65.2 59.1 67.8 68.4
60.1 61.3
58.6 52.3 50.7 59.2 59.4
59.9 50.9 52.1 60.5 60.6
Vehicle Noise: 70.0 68.2 65.6 60.4 69.0 69.5
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
114
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Single Family Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Fourth Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
0.85 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 1.11 -1.20 0.000 0.000
-21.34 1.75 -1.20 0.000 0.000
-7.73
-8.80
-11.91
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
43.174
41.500
37.626
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.0 65.2 59.1 67.8 68.4
60.1 61.3
58.6 52.3 50.7 59.2 59.4
59.9 50.9 52.1 60.5 60.6
Vehicle Noise: 70.0 68.2 65.6 60.4 69.0 69.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.0 65.2 59.1 67.8 68.4
60.1 61.3
58.6 52.3 50.7 59.2 59.4
59.9 50.9 52.1 60.5 60.6
Vehicle Noise: 70.0 68.2 65.6 60.4 69.0 69.5
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
115
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Park Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Fourth Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 120.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-4.59
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 68.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 -4.54 -1.20 0.000 0.000
-21.34 -4.44 -1.20 0.000 0.000
-0.27
-0.58
-1.90
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
99.519
98.804
97.240
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.4 61.5 59.7 53.7 62.3 62.9
54.5 55.2
53.0 46.6 45.1 53.5 53.8
53.7 44.7 46.0 54.3 54.4
Vehicle Noise: 64.5 62.7 60.1 54.9 63.4 63.9
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.4 61.5 59.7 53.7 62.3 62.9
54.5 55.2
53.0 46.6 45.1 53.5 53.8
53.7 44.7 46.0 54.3 54.4
Vehicle Noise: 64.5 62.7 60.1 54.9 63.4 63.9
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
116
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Apartments Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Second Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.77 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 2.96 -1.20 0.000 0.000
-21.34 3.31 -1.20 0.000 0.000
-1.34
-1.70
-2.84
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
32.187
31.256
29.596
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.8 68.9 67.1 61.0 69.7 70.3
62.0 62.9
60.5 54.1 52.6 61.0 61.3
61.5 52.5 53.7 62.1 62.2
Vehicle Noise: 71.9 70.1 67.5 62.3 70.8 71.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.8 68.9 67.1 61.0 69.7 70.3
62.0 62.9
60.5 54.1 52.6 61.0 61.3
61.5 52.5 53.7 62.1 62.2
Vehicle Noise: 71.9 70.1 67.5 62.3 70.8 71.3
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
117
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Single Family Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Second Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.77 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 2.96 -1.20 0.000 0.000
-21.34 3.31 -1.20 0.000 0.000
-1.34
-1.70
-2.84
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
32.187
31.256
29.596
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.8 68.9 67.1 61.0 69.7 70.3
62.0 62.9
60.5 54.1 52.6 61.0 61.3
61.5 52.5 53.7 62.1 62.2
Vehicle Noise: 71.9 70.1 67.5 62.3 70.8 71.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.8 68.9 67.1 61.0 69.7 70.3
62.0 62.9
60.5 54.1 52.6 61.0 61.3
61.5 52.5 53.7 62.1 62.2
Vehicle Noise: 71.9 70.1 67.5 62.3 70.8 71.3
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
118
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Park Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Second Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 120.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-3.72
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 68.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-5.800 -8.800
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 -3.68 -1.20 -4.900 -7.900
-21.34 -4.25 -1.20 0.000 0.000
0.08 0.00
-0.35
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
87.124
86.516
94.424
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.3 62.4 60.6 54.6 63.2 63.8
55.4 55.4
53.9 47.5 45.9 54.4 54.6
53.9 44.9 46.1 54.5 54.6
Vehicle Noise: 65.3 63.5 60.9 55.6 64.2 64.7
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
58.5 56.6 54.8 48.8 57.4 58.0
50.5 55.4
49.0 42.6 41.0 49.5 49.7
53.9 44.9 46.1 54.5 54.6
Vehicle Noise: 60.6 58.9 55.5 51.1 59.6 60.1
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
119
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Apartments Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Third Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
1.86 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 2.11 -1.20 0.000 0.000
-21.34 2.68 -1.20 0.000 0.000
-4.73
-5.50
-7.76
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
37.000
35.618
32.632
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.9 68.0 66.2 60.1 68.8 69.4
61.1 62.3
59.6 53.3 51.7 60.2 60.4
60.9 51.8 53.1 61.4 61.6
Vehicle Noise: 71.0 69.2 66.6 61.4 70.0 70.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.9 68.0 66.2 60.1 68.8 69.4
61.1 62.3
59.6 53.3 51.7 60.2 60.4
60.9 51.8 53.1 61.4 61.6
Vehicle Noise: 71.0 69.2 66.6 61.4 70.0 70.5
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
120
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Single Family Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Third Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
1.86 Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 8.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 2.11 -1.20 0.000 0.000
-21.34 2.68 -1.20 0.000 0.000
-4.73
-5.50
-7.76
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
37.000
35.618
32.632
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.9 68.0 66.2 60.1 68.8 69.4
61.1 62.3
59.6 53.3 51.7 60.2 60.4
60.9 51.8 53.1 61.4 61.6
Vehicle Noise: 71.0 69.2 66.6 61.4 70.0 70.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.9 68.0 66.2 60.1 68.8 69.4
61.1 62.3
59.6 53.3 51.7 60.2 60.4
60.9 51.8 53.1 61.4 61.6
Vehicle Noise: 71.0 69.2 66.6 61.4 70.0 70.5
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
121
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v10/31/19
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Lot No: Park Analyst: B. Maddux
Road Name: Lampson Avenue
Scenario: Third Floor With Wall
15,150
10%
52.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,515 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 120.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Barrier Elevation: 0.0
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 6.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-4.42
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 68.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
-17.39 -4.39 -1.20 0.000 0.000
-21.34 -4.31 -1.20 0.000 0.000
-0.02
-0.14
-0.99
Medium Trucks:
Heavy Trucks:
Autos:
Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.00
2.30 8.01
97.000
96.481
95.419
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.6 61.7 59.9 53.9 62.5 63.1
54.7 55.3
53.1 46.8 45.2 53.7 53.9
53.9 44.8 46.1 54.4 54.6
Vehicle Noise: 64.6 62.8 60.2 55.0 63.6 64.1
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.6 61.7 59.9 53.9 62.5 63.1
54.7 55.3
53.1 46.8 45.2 53.7 53.9
53.9 44.8 46.1 54.4 54.6
Vehicle Noise: 64.6 62.8 60.2 55.0 63.6 64.1
77.62 82.14
69.34 Road Grade: 1.0%
feet
Wednesday, February 15, 2023
122
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 8.1:
OFF-SITE TRANSPORTATION NOISE LEVEL CONTOURS
123
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
124
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Los Alamitos Blvd.
Road Name: Lampson Ave.
Scenario: E
17,339
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,430 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.40
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.63 2.64 -1.20 0.000 0.000
84.25 -21.59 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.4 68.4 66.6 60.6 69.2 69.8
63.3 64.1
62.6 56.2 54.7 63.1 63.4
63.5 54.5 55.7 64.1 64.2
Vehicle Noise: 71.3 70.4 67.2 62.6 71.1 71.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
47 102 220 474
51 110 236 508
Monday, July 1, 2024
125
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Old Ranch Plaza
Road Name: Lampson Ave.
Scenario: E
16,668
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,375 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.57
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.81 2.64 -1.20 0.000 0.000
84.25 -21.76 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.3 68.2 66.4 60.4 69.0 69.6
63.1 63.9
62.4 56.0 54.5 63.0 63.2
63.3 54.3 55.5 63.9 64.0
Vehicle Noise: 71.1 70.2 67.1 62.4 70.9 71.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
46 99 214 462
50 107 230 495
Monday, July 1, 2024
126
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Basswood St.
Road Name: Lampson Ave.
Scenario: E
13,134
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,084 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.60
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.84 2.64 -1.20 0.000 0.000
84.25 -22.80 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.2 67.2 65.4 59.4 68.0 68.6
62.0 62.9
61.4 55.0 53.5 61.9 62.2
62.3 53.3 54.5 62.9 63.0
Vehicle Noise: 70.1 69.2 66.0 61.4 69.9 70.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
39 85 183 394
42 91 196 422
Monday, July 1, 2024
127
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Candleberry St.
Road Name: Lampson Ave.
Scenario: E
11,474
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 947 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.19
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.43 2.64 -1.20 0.000 0.000
84.25 -23.38 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.7 66.6 64.8 58.8 67.4 68.0
61.5 62.3
60.8 54.4 52.9 61.3 61.6
61.7 52.7 53.9 62.3 62.4
Vehicle Noise: 69.5 68.6 65.4 60.8 69.3 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
36 78 167 360
39 83 179 386
Monday, July 1, 2024
128
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Heather St.
Road Name: Lampson Ave.
Scenario: E
11,644
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 961 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.13
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.36 2.64 -1.20 0.000 0.000
84.25 -23.32 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.7 66.7 64.9 58.8 67.5 68.1
61.5 62.4
60.8 54.5 52.9 61.4 61.6
61.8 52.7 54.0 62.3 62.5
Vehicle Noise: 69.6 68.7 65.5 60.8 69.4 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
36 78 169 364
39 84 181 390
Monday, July 1, 2024
129
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 1
Road Name: Lampson Ave.
Scenario: E
11,474
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 947 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.19
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.43 2.64 -1.20 0.000 0.000
84.25 -23.38 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.7 66.6 64.8 58.8 67.4 68.0
61.5 62.3
60.8 54.4 52.9 61.3 61.6
61.7 52.7 53.9 62.3 62.4
Vehicle Noise: 69.5 68.6 65.4 60.8 69.3 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
36 78 167 360
39 83 179 386
Monday, July 1, 2024
130
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 2
Road Name: Lampson Ave.
Scenario: E
11,474
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 947 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.19
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.43 2.64 -1.20 0.000 0.000
84.25 -23.38 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.7 66.6 64.8 58.8 67.4 68.0
61.5 62.3
60.8 54.4 52.9 61.3 61.6
61.7 52.7 53.9 62.3 62.4
Vehicle Noise: 69.5 68.6 65.4 60.8 69.3 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
36 78 167 360
39 83 179 386
Monday, July 1, 2024
131
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Rose St.
Road Name: Lampson Ave.
Scenario: E
12,059
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 995 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.97
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.21 2.64 -1.20 0.000 0.000
84.25 -23.17 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.9 66.8 65.0 59.0 67.6 68.2
61.7 62.5
61.0 54.6 53.1 61.6 61.8
61.9 52.9 54.1 62.5 62.6
Vehicle Noise: 69.7 68.8 65.7 61.0 69.5 70.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
37 80 173 372
40 86 185 399
Monday, July 1, 2024
132
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Tulip St.
Road Name: Lampson Ave.
Scenario: E
13,007
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,073 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.64
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.88 2.64 -1.20 0.000 0.000
84.25 -22.84 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.2 67.1 65.4 59.3 67.9 68.5
62.0 62.8
61.3 55.0 53.4 61.9 62.1
62.3 53.2 54.5 62.8 63.0
Vehicle Noise: 70.0 69.1 66.0 61.3 69.9 70.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
39 84 182 391
42 90 195 420
Monday, July 1, 2024
133
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Valley View St.
Road Name: Lampson Ave.
Scenario: E
10,186
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 840 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.71
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.94 2.64 -1.20 0.000 0.000
84.25 -23.90 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.1 66.1 64.3 58.3 66.9 67.5
60.9 61.8
60.3 53.9 52.4 60.8 61.1
61.2 52.2 53.4 61.8 61.9
Vehicle Noise: 69.0 68.1 64.9 60.3 68.8 69.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
33 72 154 333
36 77 166 357
Monday, July 1, 2024
134
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: E
38,360
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,165 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.56 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.67 -2.01 -1.20 0.000 0.000
82.99 -17.63 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.8 65.8 64.0 58.0 66.6 67.2
60.8 62.1
60.2 53.8 52.2 60.7 60.9
61.6 52.5 53.8 62.1 62.3
Vehicle Noise: 68.9 68.0 64.7 60.1 68.7 69.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
60 128 276 595
64 137 296 638
Monday, July 1, 2024
135
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: E
36,668
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,025 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.37 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.87 -2.01 -1.20 0.000 0.000
82.99 -17.83 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.7 65.6 63.8 57.8 66.4 67.0
60.6 62.0
60.0 53.6 52.1 60.5 60.7
61.4 52.3 53.6 61.9 62.1
Vehicle Noise: 68.7 67.8 64.5 59.9 68.5 68.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
58 124 268 578
62 133 287 619
Monday, July 1, 2024
136
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Valley View St.
Scenario: E
41,521
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,426 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.40 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.84 -2.01 -1.20 0.000 0.000
84.25 -17.80 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.6 67.6 65.8 59.7 68.4 69.0
62.4 63.2
61.7 55.4 53.8 62.3 62.5
62.7 53.6 54.9 63.2 63.3
Vehicle Noise: 70.5 69.6 66.4 61.7 70.3 70.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
76 164 353 762
82 176 379 817
Monday, July 1, 2024
137
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Valley View St.
Scenario: E
40,851
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,370 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.33 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.91 -2.01 -1.20 0.000 0.000
84.25 -17.87 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.6 67.5 65.7 59.7 68.3 68.9
62.3 63.2
61.6 55.3 53.7 62.2 62.4
62.6 53.5 54.8 63.2 63.3
Vehicle Noise: 70.4 69.5 66.3 61.7 70.2 70.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
75 162 350 753
81 174 375 808
Monday, July 1, 2024
138
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Los Alamitos Blvd.
Road Name: Lampson Ave.
Scenario: E + P
18,185
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,500 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.19
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.43 2.64 -1.20 0.000 0.000
84.25 -21.38 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.7 68.6 66.8 60.8 69.4 70.0
63.5 64.3
62.8 56.4 54.9 63.3 63.6
63.7 54.7 55.9 64.3 64.4
Vehicle Noise: 71.5 70.6 67.4 62.8 71.3 71.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
49 105 227 489
52 113 244 525
Monday, July 1, 2024
139
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Old Ranch Plaza
Road Name: Lampson Ave.
Scenario: E + P
17,514
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,445 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.35
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.59 2.64 -1.20 0.000 0.000
84.25 -21.55 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.5 68.4 66.7 60.6 69.2 69.8
63.3 64.1
62.6 56.3 54.7 63.2 63.4
63.6 54.5 55.8 64.1 64.2
Vehicle Noise: 71.3 70.4 67.3 62.6 71.2 71.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
48 103 222 477
51 110 238 512
Monday, July 1, 2024
140
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Basswood St.
Road Name: Lampson Ave.
Scenario: E + P
13,980
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,153 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.33
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.57 2.64 -1.20 0.000 0.000
84.25 -22.53 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.5 67.4 65.7 59.6 68.2 68.9
62.3 63.2
61.6 55.3 53.7 62.2 62.4
62.6 53.5 54.8 63.1 63.3
Vehicle Noise: 70.4 69.5 66.3 61.6 70.2 70.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 88 191 411
44 95 204 440
Monday, July 1, 2024
141
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Candleberry St.
Road Name: Lampson Ave.
Scenario: E + P
12,320
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,016 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.88
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.12 2.64 -1.20 0.000 0.000
84.25 -23.07 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.0 66.9 65.1 59.1 67.7 68.3
61.8 62.6
61.1 54.7 53.2 61.6 61.9
62.0 53.0 54.2 62.6 62.7
Vehicle Noise: 69.8 68.9 65.7 61.1 69.6 70.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
38 81 175 377
40 87 188 405
Monday, July 1, 2024
142
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Heather St.
Road Name: Lampson Ave.
Scenario: E + P
12,490
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,030 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.82
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.06 2.64 -1.20 0.000 0.000
84.25 -23.01 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.0 67.0 65.2 59.1 67.8 68.4
61.8 62.7
61.2 54.8 53.2 61.7 61.9
62.1 53.0 54.3 62.7 62.8
Vehicle Noise: 69.9 69.0 65.8 61.1 69.7 70.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
38 82 177 381
41 88 190 409
Monday, July 1, 2024
143
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 1
Road Name: Lampson Ave.
Scenario: E + P
12,321
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,016 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.88
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.12 2.64 -1.20 0.000 0.000
84.25 -23.07 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.0 66.9 65.1 59.1 67.7 68.3
61.8 62.6
61.1 54.7 53.2 61.6 61.9
62.0 53.0 54.2 62.6 62.7
Vehicle Noise: 69.8 68.9 65.7 61.1 69.6 70.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
38 81 175 377
40 87 188 405
Monday, July 1, 2024
144
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 2
Road Name: Lampson Ave.
Scenario: E + P
12,166
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,004 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.94
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.17 2.64 -1.20 0.000 0.000
84.25 -23.13 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.9 66.8 65.1 59.0 67.6 68.3
61.7 62.6
61.0 54.7 53.1 61.6 61.8
62.0 52.9 54.2 62.5 62.7
Vehicle Noise: 69.8 68.9 65.7 61.0 69.6 70.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
37 81 174 374
40 86 186 401
Monday, July 1, 2024
145
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Rose St.
Road Name: Lampson Ave.
Scenario: E + P
12,751
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,052 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.73
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.97 2.64 -1.20 0.000 0.000
84.25 -22.93 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.1 67.0 65.3 59.2 67.9 68.5
61.9 62.8
61.2 54.9 53.3 61.8 62.0
62.2 53.1 54.4 62.7 62.9
Vehicle Noise: 70.0 69.1 65.9 61.2 69.8 70.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
39 83 179 386
41 89 192 414
Monday, July 1, 2024
146
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Tulip St.
Road Name: Lampson Ave.
Scenario: E + P
13,699
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,130 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.42
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.66 2.64 -1.20 0.000 0.000
84.25 -22.61 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.4 67.4 65.6 59.5 68.2 68.8
62.2 63.1
61.6 55.2 53.6 62.1 62.3
62.5 53.4 54.7 63.1 63.2
Vehicle Noise: 70.3 69.4 66.2 61.5 70.1 70.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 87 188 405
43 94 202 435
Monday, July 1, 2024
147
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Valley View St.
Road Name: Lampson Ave.
Scenario: E + P
10,416
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 859 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.61
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.85 2.64 -1.20 0.000 0.000
84.25 -23.80 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.2 66.2 64.4 58.3 67.0 67.6
61.0 61.9
60.4 54.0 52.5 60.9 61.2
61.3 52.3 53.5 61.9 62.0
Vehicle Noise: 69.1 68.2 65.0 60.4 68.9 69.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
34 73 157 337
36 78 168 362
Monday, July 1, 2024
148
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: E + P
38,668
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,190 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.60 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.64 -2.01 -1.20 0.000 0.000
82.99 -17.60 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.9 65.8 64.1 58.0 66.6 67.2
60.9 62.2
60.2 53.8 52.3 60.7 61.0
61.6 52.6 53.8 62.2 62.3
Vehicle Noise: 68.9 68.0 64.7 60.2 68.7 69.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
60 129 278 599
64 138 298 641
Monday, July 1, 2024
149
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: E + P
37,206
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,069 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.43 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.81 -2.01 -1.20 0.000 0.000
82.99 -17.76 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.7 65.7 63.9 57.8 66.5 67.1
60.7 62.0
60.0 53.7 52.1 60.6 60.8
61.4 52.4 53.6 62.0 62.1
Vehicle Noise: 68.7 67.8 64.6 60.0 68.5 69.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
58 126 271 583
62 135 290 625
Monday, July 1, 2024
150
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Valley View St.
Scenario: E + P
41,675
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,438 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.41 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.83 -2.01 -1.20 0.000 0.000
84.25 -17.78 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.6 67.6 65.8 59.8 68.4 69.0
62.4 63.3
61.7 55.4 53.8 62.3 62.5
62.7 53.6 54.9 63.2 63.4
Vehicle Noise: 70.5 69.6 66.4 61.7 70.3 70.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
76 164 354 763
82 176 380 819
Monday, July 1, 2024
151
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Valley View St.
Scenario: E + P
41,159
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,396 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.36 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.88 -2.01 -1.20 0.000 0.000
84.25 -17.84 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.6 67.5 65.8 59.7 68.3 68.9
62.4 63.2
61.7 55.3 53.8 62.2 62.5
62.6 53.6 54.8 63.2 63.3
Vehicle Noise: 70.4 69.5 66.4 61.7 70.2 70.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
76 163 351 757
81 175 377 812
Monday, July 1, 2024
152
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Los Alamitos Blvd.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
22,038
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,818 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
0.65 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.59 2.64 -1.20 0.000 0.000
84.25 -20.55 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.5 69.4 67.7 61.6 70.2 70.8
64.3 65.1
63.6 57.3 55.7 64.2 64.4
64.5 55.5 56.8 65.1 65.2
Vehicle Noise: 72.3 71.4 68.3 63.6 72.1 72.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
56 120 258 556
60 129 277 597
Monday, July 1, 2024
153
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Old Ranch Plaza
Road Name: Lampson Ave.
Scenario: OY(2026) NP
19,346
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,596 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
0.08 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.16 2.64 -1.20 0.000 0.000
84.25 -21.11 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.9 68.9 67.1 61.0 69.7 70.3
63.7 64.6
63.1 56.7 55.1 63.6 63.8
64.0 54.9 56.2 64.6 64.7
Vehicle Noise: 71.8 70.9 67.7 63.0 71.6 72.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
51 110 237 510
55 118 254 547
Monday, July 1, 2024
154
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Basswood St.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
15,521
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,280 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.88
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.12 2.64 -1.20 0.000 0.000
84.25 -22.07 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.0 67.9 66.1 60.1 68.7 69.3
62.8 63.6
62.1 55.7 54.2 62.7 62.9
63.0 54.0 55.2 63.6 63.7
Vehicle Noise: 70.8 69.9 66.8 62.1 70.6 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 95 204 440
47 102 219 472
Monday, July 1, 2024
155
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Candleberry St.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
13,804
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,139 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.39
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.62 2.64 -1.20 0.000 0.000
84.25 -22.58 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.5 67.4 65.6 59.6 68.2 68.8
62.3 63.1
61.6 55.2 53.7 62.1 62.4
62.5 53.5 54.7 63.1 63.2
Vehicle Noise: 70.3 69.4 66.2 61.6 70.1 70.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 88 189 407
44 94 203 437
Monday, July 1, 2024
156
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Heather St.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
14,070
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,161 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.30
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.54 2.64 -1.20 0.000 0.000
84.25 -22.50 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.5 67.5 65.7 59.7 68.3 68.9
62.3 63.2
61.7 55.3 53.8 62.2 62.5
62.6 53.6 54.8 63.2 63.3
Vehicle Noise: 70.4 69.5 66.3 61.7 70.2 70.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 89 191 412
44 95 205 442
Monday, July 1, 2024
157
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 1
Road Name: Lampson Ave.
Scenario: OY(2026) NP
13,886
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,146 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.36
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.60 2.64 -1.20 0.000 0.000
84.25 -22.55 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.5 67.4 65.7 59.6 68.2 68.8
62.3 63.1
61.6 55.3 53.7 62.2 62.4
62.5 53.5 54.8 63.1 63.2
Vehicle Noise: 70.3 69.4 66.3 61.6 70.1 70.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 88 190 409
44 94 204 438
Monday, July 1, 2024
158
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 2
Road Name: Lampson Ave.
Scenario: OY(2026) NP
13,886
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,146 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.36
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.60 2.64 -1.20 0.000 0.000
84.25 -22.55 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.5 67.4 65.7 59.6 68.2 68.8
62.3 63.1
61.6 55.3 53.7 62.2 62.4
62.5 53.5 54.8 63.1 63.2
Vehicle Noise: 70.3 69.4 66.3 61.6 70.1 70.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 88 190 409
44 94 204 438
Monday, July 1, 2024
159
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Rose St.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
14,599
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,204 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.14
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.38 2.64 -1.20 0.000 0.000
84.25 -22.34 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.6 65.9 59.8 68.4 69.0
62.5 63.3
61.8 55.5 53.9 62.4 62.6
62.8 53.7 55.0 63.3 63.5
Vehicle Noise: 70.6 69.6 66.5 61.8 70.4 70.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
42 91 196 423
45 98 210 453
Monday, July 1, 2024
160
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Tulip St.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
15,737
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,298 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.82
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.06 2.64 -1.20 0.000 0.000
84.25 -22.01 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.0 68.0 66.2 60.1 68.8 69.4
62.8 63.7
62.2 55.8 54.3 62.7 62.9
63.1 54.0 55.3 63.7 63.8
Vehicle Noise: 70.9 70.0 66.8 62.1 70.7 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 96 206 444
48 103 221 477
Monday, July 1, 2024
161
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Valley View St.
Road Name: Lampson Ave.
Scenario: OY(2026) NP
11,516
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 950 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.17
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.41 2.64 -1.20 0.000 0.000
84.25 -23.37 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.7 66.6 64.8 58.8 67.4 68.0
61.5 62.3
60.8 54.4 52.9 61.4 61.6
61.7 52.7 53.9 62.3 62.4
Vehicle Noise: 69.5 68.6 65.5 60.8 69.3 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
36 78 167 361
39 83 180 387
Monday, July 1, 2024
162
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: OY(2026) NP
44,738
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,691 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.23 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.01 -2.01 -1.20 0.000 0.000
82.99 -16.96 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.5 66.5 64.7 58.6 67.3 67.9
61.5 62.8
60.8 54.5 52.9 61.4 61.6
62.2 53.2 54.4 62.8 62.9
Vehicle Noise: 69.5 68.6 65.4 60.8 69.3 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
66 142 306 660
71 152 328 706
Monday, July 1, 2024
163
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: OY(2026) NP
43,352
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,577 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.10 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.14 -2.01 -1.20 0.000 0.000
82.99 -17.10 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.4 66.3 64.5 58.5 67.1 67.7
61.4 62.7
60.7 54.3 52.8 61.2 61.5
62.1 53.1 54.3 62.7 62.8
Vehicle Noise: 69.4 68.5 65.2 60.7 69.2 69.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
65 139 300 646
69 149 321 692
Monday, July 1, 2024
164
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Valley View St.
Scenario: OY(2026) NP
46,216
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,813 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.86 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.38 -2.01 -1.20 0.000 0.000
84.25 -17.33 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.1 68.0 66.3 60.2 68.8 69.4
62.9 63.7
62.2 55.8 54.3 62.7 63.0
63.1 54.1 55.3 63.7 63.8
Vehicle Noise: 70.9 70.0 66.9 62.2 70.7 71.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
82 176 380 818
88 189 407 877
Monday, July 1, 2024
165
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Valley View St.
Scenario: OY(2026) NP
45,244
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,733 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.77 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.47 -2.01 -1.20 0.000 0.000
84.25 -17.43 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.0 67.9 66.2 60.1 68.7 69.3
62.8 63.6
62.1 55.7 54.2 62.6 62.9
63.0 54.0 55.2 63.6 63.7
Vehicle Noise: 70.8 69.9 66.8 62.1 70.6 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
81 174 374 806
86 186 401 865
Monday, July 1, 2024
166
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Los Alamitos Blvd.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
22,884
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,888 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
0.81 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.43 2.64 -1.20 0.000 0.000
84.25 -20.39 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.7 69.6 67.8 61.8 70.4 71.0
64.5 65.3
63.8 57.4 55.9 64.3 64.6
64.7 55.7 56.9 65.3 65.4
Vehicle Noise: 72.5 71.6 68.4 63.8 72.3 72.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
57 123 265 570
61 132 284 612
Monday, July 1, 2024
167
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Old Ranch Plaza
Road Name: Lampson Ave.
Scenario: OY(2026) WP
20,192
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,666 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
0.27 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.97 2.64 -1.20 0.000 0.000
84.25 -20.93 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.1 69.0 67.3 61.2 69.8 70.5
63.9 64.8
63.2 56.9 55.3 63.8 64.0
64.2 55.1 56.4 64.7 64.9
Vehicle Noise: 72.0 71.1 67.9 63.2 71.8 72.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
52 113 244 525
56 121 261 563
Monday, July 1, 2024
168
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Basswood St.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
16,367
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,350 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.65
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.89 2.64 -1.20 0.000 0.000
84.25 -21.84 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.2 68.1 66.4 60.3 68.9 69.5
63.0 63.8
62.3 56.0 54.4 62.9 63.1
63.3 54.2 55.5 63.8 64.0
Vehicle Noise: 71.0 70.1 67.0 62.3 70.9 71.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
46 98 212 456
49 105 227 489
Monday, July 1, 2024
169
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Candleberry St.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
14,650
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,209 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.13
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.37 2.64 -1.20 0.000 0.000
84.25 -22.32 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.7 65.9 59.8 68.5 69.1
62.5 63.4
61.8 55.5 53.9 62.4 62.6
62.8 53.7 55.0 63.3 63.5
Vehicle Noise: 70.6 69.7 66.5 61.8 70.4 70.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
42 91 197 424
45 98 211 454
Monday, July 1, 2024
170
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Heather St.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
14,916
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,231 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.05
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.29 2.64 -1.20 0.000 0.000
84.25 -22.24 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.8 67.7 66.0 59.9 68.5 69.1
62.6 63.4
61.9 55.6 54.0 62.5 62.7
62.9 53.8 55.1 63.4 63.5
Vehicle Noise: 70.6 69.7 66.6 61.9 70.5 70.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
43 92 199 429
46 99 213 460
Monday, July 1, 2024
171
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 1
Road Name: Lampson Ave.
Scenario: OY(2026) WP
14,733
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,215 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.10
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.34 2.64 -1.20 0.000 0.000
84.25 -22.30 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.7 65.9 59.9 68.5 69.1
62.5 63.4
61.9 55.5 54.0 62.4 62.7
62.8 53.8 55.0 63.4 63.5
Vehicle Noise: 70.6 69.7 66.5 61.9 70.4 70.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
43 92 197 425
46 98 212 456
Monday, July 1, 2024
172
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 2
Road Name: Lampson Ave.
Scenario: OY(2026) WP
14,578
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,203 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.39 2.64 -1.20 0.000 0.000
84.25 -22.34 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.6 65.9 59.8 68.4 69.0
62.5 63.3
61.8 55.5 53.9 62.4 62.6
62.8 53.7 55.0 63.3 63.4
Vehicle Noise: 70.5 69.6 66.5 61.8 70.4 70.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
42 91 196 422
45 98 210 453
Monday, July 1, 2024
173
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Rose St.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
15,291
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,262 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.94
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.18 2.64 -1.20 0.000 0.000
84.25 -22.14 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.8 66.1 60.0 68.6 69.2
62.7 63.5
62.0 55.7 54.1 62.6 62.8
63.0 53.9 55.2 63.5 63.7
Vehicle Noise: 70.8 69.8 66.7 62.0 70.6 71.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 94 202 436
47 101 217 468
Monday, July 1, 2024
174
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Tulip St.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
16,429
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,355 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.63
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.87 2.64 -1.20 0.000 0.000
84.25 -21.82 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.2 68.1 66.4 60.3 69.0 69.6
63.0 63.9
62.3 56.0 54.4 62.9 63.1
63.3 54.2 55.5 63.8 64.0
Vehicle Noise: 71.1 70.2 67.0 62.3 70.9 71.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
46 99 212 457
49 106 228 490
Monday, July 1, 2024
175
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Valley View St.
Road Name: Lampson Ave.
Scenario: OY(2026) WP
11,746
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 969 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-2.09
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -19.33 2.64 -1.20 0.000 0.000
84.25 -23.28 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.8 66.7 64.9 58.9 67.5 68.1
61.6 62.4
60.9 54.5 53.0 61.4 61.7
61.8 52.8 54.0 62.4 62.5
Vehicle Noise: 69.6 68.7 65.5 60.9 69.4 69.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
37 79 170 366
39 84 182 392
Monday, July 1, 2024
176
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: OY(2026) WP
45,046
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,716 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.26 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -12.98 -2.01 -1.20 0.000 0.000
82.99 -16.93 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.5 66.5 64.7 58.7 67.3 67.9
61.5 62.8
60.9 54.5 52.9 61.4 61.6
62.3 53.2 54.5 62.8 63.0
Vehicle Noise: 69.6 68.7 65.4 60.8 69.4 69.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
66 143 308 663
71 153 329 710
Monday, July 1, 2024
177
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: OY(2026) WP
43,890
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,621 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.15 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -13.09 -2.01 -1.20 0.000 0.000
82.99 -17.05 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.4 66.4 64.6 58.5 67.2 67.8
61.4 62.7
60.7 54.4 52.8 61.3 61.5
62.1 53.1 54.4 62.7 62.8
Vehicle Noise: 69.4 68.5 65.3 60.7 69.3 69.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
65 140 302 651
70 150 324 697
Monday, July 1, 2024
178
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Valley View St.
Scenario: OY(2026) WP
46,370
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,826 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.88 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.36 -2.01 -1.20 0.000 0.000
84.25 -17.32 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.1 68.0 66.3 60.2 68.8 69.5
62.9 63.7
62.2 55.8 54.3 62.8 63.0
63.1 54.1 55.3 63.7 63.8
Vehicle Noise: 70.9 70.0 66.9 62.2 70.8 71.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
82 177 380 820
88 189 408 879
Monday, July 1, 2024
179
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Valley View St.
Scenario: OY(2026) WP
45,552
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,758 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
3.80 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.44 -2.01 -1.20 0.000 0.000
84.25 -17.40 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.0 68.0 66.2 60.1 68.8 69.4
62.8 63.6
62.1 55.8 54.2 62.7 62.9
63.1 54.0 55.3 63.6 63.8
Vehicle Noise: 70.9 70.0 66.8 62.1 70.7 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
81 175 376 810
87 187 403 869
Monday, July 1, 2024
180
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Los Alamitos Blvd.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
24,242
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,000 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
1.06 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.18 2.64 -1.20 0.000 0.000
84.25 -20.13 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.9 69.8 68.1 62.0 70.6 71.2
64.7 65.5
64.0 57.7 56.1 64.6 64.8
65.0 55.9 57.2 65.5 65.7
Vehicle Noise: 72.8 71.8 68.7 64.0 72.6 73.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
59 128 275 593
64 137 295 636
Monday, July 1, 2024
181
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Old Ranch Plaza
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
20,306
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,675 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
0.29 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.95 2.64 -1.20 0.000 0.000
84.25 -20.90 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.1 69.1 67.3 61.2 69.9 70.5
63.9 64.8
63.3 56.9 55.4 63.8 64.1
64.2 55.2 56.4 64.8 64.9
Vehicle Noise: 72.0 71.1 67.9 63.3 71.8 72.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
53 113 244 527
56 122 262 565
Monday, July 1, 2024
182
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Basswood St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
16,277
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,343 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.67
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.91 2.64 -1.20 0.000 0.000
84.25 -21.86 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.2 68.1 66.3 60.3 68.9 69.5
63.0 63.8
62.3 55.9 54.4 62.9 63.1
63.2 54.2 55.4 63.8 63.9
Vehicle Noise: 71.0 70.1 67.0 62.3 70.8 71.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
45 98 211 454
49 105 226 487
Monday, July 1, 2024
183
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Candleberry St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
14,464
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,193 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.18
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.42 2.64 -1.20 0.000 0.000
84.25 -22.38 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.6 65.8 59.8 68.4 69.0
62.5 63.3
61.8 55.4 53.9 62.3 62.6
62.7 53.7 54.9 63.3 63.4
Vehicle Noise: 70.5 69.6 66.4 61.8 70.3 70.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
42 91 195 420
45 97 209 451
Monday, July 1, 2024
184
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Heather St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
14,741
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,216 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.10
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.34 2.64 -1.20 0.000 0.000
84.25 -22.30 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.7 65.9 59.9 68.5 69.1
62.5 63.4
61.9 55.5 54.0 62.4 62.7
62.8 53.8 55.0 63.4 63.5
Vehicle Noise: 70.6 69.7 66.5 61.9 70.4 70.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
43 92 197 425
46 98 212 456
Monday, July 1, 2024
185
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 1
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
14,546
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,200 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.16
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.40 2.64 -1.20 0.000 0.000
84.25 -22.35 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.6 65.9 59.8 68.4 69.0
62.5 63.3
61.8 55.5 53.9 62.4 62.6
62.7 53.7 55.0 63.3 63.4
Vehicle Noise: 70.5 69.6 66.5 61.8 70.3 70.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
42 91 196 422
45 97 210 452
Monday, July 1, 2024
186
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 2
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
14,546
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,200 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.16
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.40 2.64 -1.20 0.000 0.000
84.25 -22.35 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.7 67.6 65.9 59.8 68.4 69.0
62.5 63.3
61.8 55.5 53.9 62.4 62.6
62.7 53.7 55.0 63.3 63.4
Vehicle Noise: 70.5 69.6 66.5 61.8 70.3 70.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
42 91 196 422
45 97 210 452
Monday, July 1, 2024
187
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Rose St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
15,294
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,262 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.94
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.18 2.64 -1.20 0.000 0.000
84.25 -22.14 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.8 66.1 60.0 68.6 69.2
62.7 63.5
62.0 55.7 54.1 62.6 62.8
63.0 53.9 55.2 63.5 63.7
Vehicle Noise: 70.8 69.8 66.7 62.0 70.6 71.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 94 202 436
47 101 217 468
Monday, July 1, 2024
188
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Tulip St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
16,486
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,360 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.62
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.85 2.64 -1.20 0.000 0.000
84.25 -21.81 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.2 68.2 66.4 60.3 69.0 69.6
63.0 63.9
62.4 56.0 54.5 62.9 63.1
63.3 54.3 55.5 63.9 64.0
Vehicle Noise: 71.1 70.2 67.0 62.3 70.9 71.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
46 99 213 458
49 106 228 492
Monday, July 1, 2024
189
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Valley View St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) NP
12,685
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,047 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.75
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.99 2.64 -1.20 0.000 0.000
84.25 -22.95 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.1 67.0 65.3 59.2 67.8 68.4
61.9 62.7
61.2 54.9 53.3 61.8 62.0
62.1 53.1 54.4 62.7 62.8
Vehicle Noise: 69.9 69.0 65.9 61.2 69.7 70.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
38 83 179 385
41 89 192 413
Monday, July 1, 2024
190
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: GBPO (2045) NP
49,212
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,060 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.65 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -12.59 -2.01 -1.20 0.000 0.000
82.99 -16.55 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.9 66.9 65.1 59.0 67.7 68.3
61.9 63.2
61.2 54.9 53.3 61.8 62.0
62.6 53.6 54.9 63.2 63.3
Vehicle Noise: 69.9 69.0 65.8 61.2 69.8 70.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
70 151 326 703
75 162 349 753
Monday, July 1, 2024
191
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: GBPO (2045) NP
47,688
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,934 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.51 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -12.73 -2.01 -1.20 0.000 0.000
82.99 -16.69 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.8 66.7 65.0 58.9 67.5 68.1
61.8 63.1
61.1 54.7 53.2 61.7 61.9
62.5 53.5 54.7 63.1 63.2
Vehicle Noise: 69.8 68.9 65.6 61.1 69.6 70.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
69 148 320 688
74 159 342 737
Monday, July 1, 2024
192
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Valley View St.
Scenario: GBPO (2045) NP
50,838
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,194 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.28 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -12.96 -2.01 -1.20 0.000 0.000
84.25 -16.92 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.5 68.4 66.7 60.6 69.2 69.9
63.3 64.1
62.6 56.2 54.7 63.2 63.4
63.5 54.5 55.7 64.1 64.2
Vehicle Noise: 71.3 70.4 67.3 62.6 71.2 71.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
87 188 405 872
93 201 434 935
Monday, July 1, 2024
193
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Valley View St.
Scenario: GBPO (2045) NP
49,769
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,106 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.18 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.06 -2.01 -1.20 0.000 0.000
84.25 -17.01 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.4 68.4 66.6 60.5 69.2 69.8
63.2 64.0
62.5 56.1 54.6 63.1 63.3
63.4 54.4 55.7 64.0 64.1
Vehicle Noise: 71.3 70.3 67.2 62.5 71.1 71.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
86 185 399 859
92 199 428 922
Monday, July 1, 2024
194
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Los Alamitos Blvd.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
25,088
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,070 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
1.21 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.03 2.64 -1.20 0.000 0.000
84.25 -19.99 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.1 70.0 68.2 62.2 70.8 71.4
64.9 65.7
64.2 57.8 56.3 64.7 65.0
65.1 56.1 57.3 65.7 65.8
Vehicle Noise: 72.9 72.0 68.8 64.2 72.7 73.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
61 131 281 606
65 140 302 650
Monday, July 1, 2024
195
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Old Ranch Plaza
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
21,152
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,745 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
0.47 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -16.77 2.64 -1.20 0.000 0.000
84.25 -20.73 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.3 69.2 67.5 61.4 70.0 70.7
64.1 65.0
63.4 57.1 55.5 64.0 64.2
64.4 55.3 56.6 64.9 65.1
Vehicle Noise: 72.2 71.3 68.1 63.4 72.0 72.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
54 117 251 541
58 125 269 580
Monday, July 1, 2024
196
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Basswood St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
17,123
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,413 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.45
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.69 2.64 -1.20 0.000 0.000
84.25 -21.64 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.4 68.3 66.6 60.5 69.1 69.7
63.2 64.0
62.5 56.2 54.6 63.1 63.3
63.5 54.4 55.7 64.0 64.1
Vehicle Noise: 71.2 70.3 67.2 62.5 71.1 71.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
47 101 218 470
50 109 234 504
Monday, July 1, 2024
197
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Candleberry St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
15,310
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,263 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.94
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.17 2.64 -1.20 0.000 0.000
84.25 -22.13 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.8 66.1 60.0 68.6 69.3
62.7 63.6
62.0 55.7 54.1 62.6 62.8
63.0 53.9 55.2 63.5 63.7
Vehicle Noise: 70.8 69.9 66.7 62.0 70.6 71.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 94 203 436
47 101 217 468
Monday, July 1, 2024
198
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Heather St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
15,587
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,286 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.86
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.10 2.64 -1.20 0.000 0.000
84.25 -22.05 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.0 67.9 66.2 60.1 68.7 69.3
62.8 63.6
62.1 55.8 54.2 62.7 62.9
63.0 54.0 55.3 63.6 63.7
Vehicle Noise: 70.8 69.9 66.8 62.1 70.6 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 95 205 442
47 102 220 474
Monday, July 1, 2024
199
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 1
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
15,393
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,270 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.91
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.15 2.64 -1.20 0.000 0.000
84.25 -22.11 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.9 66.1 60.0 68.7 69.3
62.7 63.6
62.1 55.7 54.2 62.6 62.8
63.0 54.0 55.2 63.6 63.7
Vehicle Noise: 70.8 69.9 66.7 62.0 70.6 71.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
44 94 203 438
47 101 218 470
Monday, July 1, 2024
200
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Driveway 2
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
15,238
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,257 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.96
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.20 2.64 -1.20 0.000 0.000
84.25 -22.15 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.8 66.1 60.0 68.6 69.2
62.7 63.5
62.0 55.7 54.1 62.6 62.8
62.9 53.9 55.2 63.5 63.6
Vehicle Noise: 70.7 69.8 66.7 62.0 70.5 71.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
43 94 202 435
47 101 217 466
Monday, July 1, 2024
201
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Rose St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
15,986
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,319 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.75
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.99 2.64 -1.20 0.000 0.000
84.25 -21.94 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.1 68.0 66.3 60.2 68.8 69.4
62.9 63.7
62.2 55.9 54.3 62.8 63.0
63.2 54.1 55.4 63.7 63.8
Vehicle Noise: 70.9 70.0 66.9 62.2 70.8 71.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
45 97 208 449
48 104 224 482
Monday, July 1, 2024
202
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Tulip St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
17,178
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,417 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-0.44
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -17.68 2.64 -1.20 0.000 0.000
84.25 -21.63 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.4 68.3 66.6 60.5 69.1 69.7
63.2 64.1
62.5 56.2 54.6 63.1 63.3
63.5 54.4 55.7 64.0 64.2
Vehicle Noise: 71.3 70.4 67.2 62.5 71.1 71.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
47 101 219 471
51 109 235 505
Monday, July 1, 2024
203
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: e/o Valley View St.
Road Name: Lampson Ave.
Scenario: GBPO (2045) WP
12,915
8.25%
40.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,065 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 40.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 46 feet
REMEL Traffic Flow Distance
-1.68
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
2.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -18.91 2.64 -1.20 0.000 0.000
84.25 -22.87 2.63 -1.20 0.000 0.000
-4.59
-4.87
-5.56
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
33.106
32.838
32.864
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.2 67.1 65.3 59.3 67.9 68.5
62.0 62.8
61.3 54.9 53.4 61.9 62.1
62.2 53.2 54.4 62.8 62.9
Vehicle Noise: 70.0 69.1 66.0 61.3 69.8 70.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
39 84 181 390
42 90 194 418
Monday, July 1, 2024
204
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: GBPO (2045) WP
49,520
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,085 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.67 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -12.57 -2.01 -1.20 0.000 0.000
82.99 -16.52 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.0 66.9 65.1 59.1 67.7 68.3
61.9 63.3
61.3 54.9 53.4 61.8 62.0
62.7 53.6 54.9 63.2 63.4
Vehicle Noise: 70.0 69.1 65.8 61.2 69.8 70.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
71 152 328 706
76 163 351 756
Monday, July 1, 2024
205
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Los Alamitos Blvd.
Scenario: GBPO (2045) WP
48,226
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,979 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.56 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -12.68 -2.01 -1.20 0.000 0.000
82.99 -16.64 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.8 66.8 65.0 59.0 67.6 68.2
61.8 63.1
61.1 54.8 53.2 61.7 61.9
62.6 53.5 54.8 63.1 63.3
Vehicle Noise: 69.9 69.0 65.7 61.1 69.7 70.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
69 149 322 694
74 160 345 743
Monday, July 1, 2024
206
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: n/o Lampson Ave.
Road Name: Valley View St.
Scenario: GBPO (2045) WP
50,992
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,207 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.29 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -12.95 -2.01 -1.20 0.000 0.000
84.25 -16.91 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.5 68.5 66.7 60.6 69.3 69.9
63.3 64.1
62.6 56.3 54.7 63.2 63.4
63.5 54.5 55.8 64.1 64.2
Vehicle Noise: 71.4 70.5 67.3 62.6 71.2 71.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
87 188 405 873
94 202 435 937
Monday, July 1, 2024
207
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL
SITE SPECIFIC INPUT DATA
Project Name: 4665 Lampson Avenue
Job Number: 14501
Road Segment: s/o Lampson Ave.
Road Name: Valley View St.
Scenario: GBPO (2045) WP
50,077
8.25%
73.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,131 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 73.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 58 feet
REMEL Traffic Flow Distance
4.21 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 77.5% 12.9% 9.6% 97.42%
84.8% 4.9% 10.3% 1.84%
86.5% 2.7% 10.8% 0.74%
-2.03
Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -13.03 -2.01 -1.20 0.000 0.000
84.25 -16.98 -2.02 -1.20 0.000 0.000
-4.72
-4.88
-5.26
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.006
67.179
67.047
67.060
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.4 68.4 66.6 60.6 69.2 69.8
63.2 64.1
62.5 56.2 54.6 63.1 63.3
63.5 54.4 55.7 64.0 64.2
Vehicle Noise: 71.3 70.4 67.2 62.5 71.1 71.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
86 186 400 863
93 199 430 926
Monday, July 1, 2024
208
4665 Lampson Avenue
14501-10 Noise Study.docx
APPENDIX 10.1:
CARRIER 25HBC5 AIR CONDITIONING UNIT
209
4665 Lampson Avenue
14501-10 Noise Study.docx
This page intentionally left blank
210
Product Data
24ABC6
Comfortt16 Air Conditioner
with Puronr Refrigerant
1---1/2 to 5 Nominal Tons
the environmentally sound refrigerant
Carrier’s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 24ABC has been designed utilizing Carrier’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.
This product has been designed and manufactured to meet Energy Starr criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings information.
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 14 -- 16.5 SEER/11.0-- 13.5 EER
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 76 dBA
S Sound level as low as 74 dBA with accessory sound
blanket
Comfort
S System supports Edger Thermidistatt or standard
thermostat controls
Reliability
S Puronr refrigerant -- environmentally sound, won’t
deplete the ozone layer and low lifetime servce cost.
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S Filter drier
S Balanced refrigeration system for maximum reliability Durability
WeatherArmort protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard standard
S Baked--on, complete outer coverage, powder paint
Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
S Low ambient (down to --20_F/--28.9_C)) with
accessory kit
211
2 MODEL NUMBER NOMENCLATURE
1 2 3 4 5 6 7 8 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
24 A B C 6 36 A 0 0 3 0
Product
Series
Product
Family Tier Major
Series SEER Cooling
Capacity
Grille
Variations Open Open Voltage Series
24=AC A=RES AC B=Comfort C=Puron 6=16 SEER A = Dense
W = Standard
0=Not
Defined
0=Not
Defined
3=208/230 ---1 0=
Original
Series
the environmentally sound refrigerant
This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
STANDARD FEATURES
Feature 18 24 30 36 42 48 / 49 60 / 61
Puron Refrigerant X X X X X X X
Maximum SEER * 16.0 16.0 16.5 16.5 16.0 16.0 16.0
Scroll Compressor X X X X X X X
Field Installed Filter Drier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
Dense Grille X X X X X X X
* With approved combinations
X = Standard
PHYSICAL DATA
UNIT SIZE ---VOLTAGE, SERIES 18 --- 31 24 --- 30 30 --- 30 36 --- 30 42 --- 30 48 --- 31 49 --- 30 60 --- 30 61 --- 30 Operating Weight lb (kg) 125
(56.7)
147
(66.5)
153
(69.3)
165
(74.8)
213
(96.4)
264
(119.7)
231
(104.8)
272
(123.4)
272
(123.4)
Shipping Weight lb (kg) 154
(69.9)
183
(82.8)
188
(85.2)
204
(92.5)
254
(115.2)
317
(143.8)
269
(222.0)
310
(140.6)
310
(140.6)
Compressor Type Scroll
REFRIGERANT Puron® (R ---410A)
Control TXV (Puron® Hard Shutoff)
Charge lb (kg) 4.60
(2.09)
6.00 (2.72)
6.81 (3.09)
7.00 (3.18)
8.62 (3.91)
13.0 (5.90)
9.00 (4.08)
14.50 (6.58)
14.50 (6.58)
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical Vertical
Air Qty (CFM) 1881 2614 2614 3223 3810 4046 4046 4046 4046 Motor HP 1/12 1/10 1/10 1/12 1/5 1/4 1/4 1/4 1/4
Motor RPM 1100 1100 1100 800 800 800 800 800 800
COND COIL
Face Area (Sq ft) 11.50 15.10 17.20 17.60 25.15 25.15 25.15 30.15 30.15 Fins per In. 25 25 25 25 25 20 20 20 20
Rows 1 1 1 1 1 2 1 2 2
Circuits 3 4 4 4 6 7 7 8 8
VALVE CONNECT. (In. ID)
Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8
Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor* 3/4 7/8 1 ---1/8
Max Liquid Line { 3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation. { See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 24ABC6
212
3 REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengths{ for Cooling Only Systems with Puronr Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.
See Table below for liquid line sizing and maximum lengths :
Maximum Total Equivalent Length
Outdoor Unit BELOW Indoor Unit
Size Liquid Line
Connection
Liquid
Line
Diam.
w/ TXV
AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor Vertical Separation ft (m)
0---5
(0---1.5)
6---10
(1.8---3.0)
11---20
(3.4---6.1)
21---30
(6.4---9.1)
31---40
(9.4---12.2)
41---50
(12.5---15.2)
51---60
(15.5---18.3)
61---70
(18.6---21.3)
71---80
(21.6---24.4)
18000
AC with
Puron
3/8
1/4 150 150 125 100 100 75 --- --- --- --- --- ---
5/16 250* 250* 250* 250* 250* 250* 250* 225* 150
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
24000
AC with
Puron
3/8
1/4 75 75 75 50 50 --- --- --- --- --- --- --- ---
5/16 250* 250* 250* 250* 250* 225* 175 125 100
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
30000
AC with
Puron
3/8
1/4 30 --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- --- 5/16 175 225* 200 175 125 100 75 --- --- --- ---
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
36000
AC with
Puron
3/8
5/16 175 150 150 100 100 100 75 --- --- --- ---
3//8 250* 250* 250* 250* 250* 250* 250* 250* 250*
42000
AC with
Puron
3/8
5/16 125 100 100 75 75 50 --- --- --- --- --- ---
3/8 250* 250* 250* 250* 250* 250* 250* 250* 150
48000
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 --- ---
49000
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 --- ---
60000
AC with
Puron
3/8 3/8 250* 250* 250* 225* 190 150 110 --- --- --- --- 61000
AC with
Puron
3/8 3/8 250* 250* 250* 225* 190 150 110 --- --- --- --- * Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = outside acceptable range
Maximum Total Equivalent Length
Outdoor Unit ABOVE Indoor Unit
Size Liquid Line
Connection
Liquid
Line
Diam.
w/ TXV
AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor Vertical Separation ft (m)
25 (7.6)
26---50
(7.9---15.2)
51---75
(15.5---22.9)
76---100
(23.2---30.5)
101---125
(30.8---38.1)
126---150
(38.4---45.7)
151---175
(46.0---53.3)
176---200
(53.6---61.0)
18000
AC with
Puron
3/8
1/4 175 250* 250* 250* 250* 250* 250* 250*
5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
24000
AC with
Puron
3/8
1/4 100 125 175 200 225* 250* 250* 250*
5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
30000
AC with
Puron
3/8
1/4 30 --- --- --- --- --- --- --- --- --- --- --- --- --- --- 5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
36000
AC with
Puron
3/8 5/16 225* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
42000
AC with
Puron
3/8
5/16 175 200 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
48000
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
49000
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
60000
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
61000
AC with
Puron
3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = outside acceptable range
24ABC6
213
4 REFRIGERANT CHARGE ADJUSTMENTS
Liquid Line Size Puron Charge oz/ft
3/8 0.60
(Factory charge for lineset = 9 oz)
5/16 0.40
1/4 0.27
Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system
LONG LINE APPLICATIONS
An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
For Air Conditioner systems, the chart below shows when an application is considered Long Line.
AC WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 No accessories needed within allowed
lengths
No accessories needed within allowed
lengths 175 (53.3)
5/16 120 (36.6) 50 (15.2) 120 (36.6)
3/8 80 (24.4) 35 (10.7) 80 (24.4)
Note: See Long Line Guideline for details
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant:
Unit
Nominal
Size (Btuh)
Maximum
Liquid Line
Diameters
(In. OD)
Vapor Line
Diameters
(In. OD)
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
26 --- 50
(7.9---15.2)
51 --- 80
(15.5---24.4)
81 --- 100
(24.7---30.5)
101 --- 125
(30.8---38.1)
126 --- 150
(38.4---45.7)
151 --- 175
(46.0---53.3)
176 --- 200
(53.6---61.0)
201 --- 225
(61.3---68.6)
226 --- 250
(68.9---76.2)
18000
1 Stage
AC with
Puron
3/8
1/2 1 2 3 5 6 7 8 9 11
5/8 0 1 1 1 2 2 2 3 3
3/4 0 0 0 0 1 1 1 1 1
24000
1 Stage
AC with
Puron
3/8
5/8 0 1 2 2 3 3 4 5 5
3/4 0 0 1 1 1 1 1 2 2
7/8 0 0 0 0 0 1 1 1 1
30000
1 Stage
AC with
Puron
3/8
5/8 1 2 3 3 4 5 6 7 8
3/4 0 0 1 1 1 2 2 2 3
7/8 0 0 0 0 1 1 1 1 1
36000
1 Stage
AC with
Puron
3/8
5/8 1 2 4 5 6 8 9 10 12
3/4 0 1 1 2 2 3 3 4 4
7/8 0 0 0 1 1 1 1 2 2
42000
1 Stage
AC with
Puron
3/8
3/4 0 1 2 2 3 4 4 5 6
7/8 0 0 1 1 1 2 2 2 3
1 1/8 0 0 0 0 0 0 0 0 0
48000,
49000
1 Stage
AC with
Puron
3/8
3/4 0 1 2 3 4 5 5 6 7
7/8 0 0 1 1 2 2 2 3 3
1 1/8 0 0 0 0 0 0 0 1 1
60000,
61000
1 Stage
AC with
Puron
3/8
3/4 1 2 4 5 6 7 9 10 11
7/8 0 1 2 2 3 4 4 5 5
1 1/8 0 0 0 1 1 1 1 1 1
Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 24ABC6
214