Cities Index.
Agenda packet

Orange City Council
May 26, 2026

Document
Agenda packet
Meeting
May 26, 2026
Body
Orange City Council
Pages
127
Original file
465.4 MB
Text extracted from the city's file for reading and search. Open the original on cityoforange.legistar.com. That file is the official record.

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.3 63.4 61.7 55.6 64.2 64.8

78.1 80.3

76.6 70.3 68.7 77.2 77.4

78.9 69.9 71.1 79.5 79.6
Vehicle Noise: 82.5 81.0 73.4 73.2 81.6 81.7
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.0 41.1 39.4 33.3 41.9 42.5

66.7 71.9

65.2 58.9 57.3 65.8 66.0

70.5 61.5 62.7 71.1 71.2
Vehicle Noise: 73.1 71.6 63.4 63.8 72.2 72.4

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
117
1879
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 177.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.91
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 82.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-19.200 -22.200
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -5.88 -1.20 0.000 0.000

3.93 -5.90 -1.20 0.000 0.000

58.36 0.00
-0.25
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
357.224
121.318
121.696
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.4 64.5 62.7 56.6 65.3 65.9

79.4 81.4

77.9 71.5 69.9 78.4 78.6

79.9 70.9 72.2 80.5 80.6
Vehicle Noise: 83.6 82.1 74.5 74.3 82.7 82.9
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

47.2 45.3 43.5 37.4 46.1 46.7

79.4 81.4

77.9 71.5 69.9 78.4 78.6

79.9 70.9 72.2 80.5 80.6
Vehicle Noise: 83.5 82.0 74.2 74.2 82.6 82.8

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
118
1880
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 177.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.19
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 82.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.300 -22.300
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -4.55 -1.20 -13.548 -16.548

3.93 -4.30 -1.20 -11.500 -14.500

73.50 2.96

1.60 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
372.888

98.954

95.167
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.1 64.2 62.4 56.4 65.0 65.6

80.7 83.0

79.2 72.8 71.3 79.7 80.0

81.5 72.5 73.8 82.1 82.2
Vehicle Noise: 85.0 83.6 75.9 75.8 84.2 84.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.8 41.9 40.1 34.1 42.7 43.3

64.1 68.5

62.6 56.3 54.7 63.2 63.4

67.0 58.0 59.3 67.6 67.7
Vehicle Noise: 69.8 68.4 60.3 60.6 69.0 69.1

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
119
1881
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: First Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 177.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.19
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 82.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.300 -22.300
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -4.55 -1.20 -13.548 -16.548

3.93 -4.30 -1.20 -11.500 -14.500

73.50 2.96

1.60 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
372.888

98.954

95.167
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.1 64.2 62.4 56.4 65.0 65.6

80.7 83.0

79.2 72.8 71.3 79.7 80.0

81.5 72.5 73.8 82.1 82.2
Vehicle Noise: 85.0 83.6 75.9 75.8 84.2 84.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.8 41.9 40.1 34.1 42.7 43.3

64.1 68.5

62.6 56.3 54.7 63.2 63.4

67.0 58.0 59.3 67.6 67.7
Vehicle Noise: 69.8 68.4 60.3 60.6 69.0 69.1

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
120
1882
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Second Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 177.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.17
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 82.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.242 -22.242
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -4.46 -1.20 -11.680 -14.680

3.93 -4.20 -1.20 -9.380 -12.380

64.22 1.69

0.72 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
371.544

97.610

93.823
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.1 64.2 62.4 56.4 65.0 65.6

80.8 83.1

79.3 72.9 71.4 79.8 80.1

81.6 72.6 73.9 82.2 82.3
Vehicle Noise: 85.1 83.7 76.0 75.8 84.2 84.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.9 42.0 40.2 34.1 42.8 43.4

66.1 70.7

64.6 58.2 56.7 65.1 65.4

69.3 60.2 61.5 69.8 70.0
Vehicle Noise: 72.0 70.5 62.4 62.7 71.1 71.3

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
121
1883
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Third Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 177.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.16
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 82.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.200 -22.200
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -4.44 -1.20 -9.580 -12.580

3.93 -4.18 -1.20 -6.640 -9.640

55.84 0.77

0.18 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
371.172

97.238

93.451
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.1 64.2 62.4 56.4 65.0 65.6

80.8 83.1

79.3 72.9 71.4 79.8 80.1

81.7 72.6 73.9 82.2 82.4
Vehicle Noise: 85.2 83.7 76.0 75.9 84.3 84.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.9 42.0 40.2 34.2 42.8 43.4

68.2 73.5

66.7 60.4 58.8 67.3 67.5

72.0 63.0 64.2 72.6 72.7
Vehicle Noise: 74.6 73.2 64.9 65.3 73.7 73.9

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
122
1884
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Rooftop Balconies
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 177.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.17
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 82.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.168 -22.168
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -4.48 -1.20 -6.870 -9.870

3.93 -4.22 -1.20 -4.900 -7.900

48.38 0.21

0.00 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
371.784

97.850

94.063
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.1 64.2 62.4 56.4 65.0 65.6

80.8 83.0

79.3 72.9 71.3 79.8 80.0

81.6 72.6 73.8 82.2 82.3
Vehicle Noise: 85.1 83.7 76.0 75.8 84.2 84.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.9 42.0 40.3 34.2 42.8 43.4

70.9 75.1

69.4 63.0 61.5 69.9 70.2

73.7 64.7 65.9 74.3 74.4
Vehicle Noise: 76.5 75.1 67.0 67.3 75.7 75.8

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
123
1885
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 145.0
Highway Data
feet
feet
vehicles
Road Elevation: 276.0
Barrier Elevation: 276.0
Pad Elevation: 268.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.32
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 50.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-18.984 -21.984
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -1.30 -1.20 -4.900 -7.900

3.93 -3.69 -1.20 0.000 0.000

39.21 0.00
-0.14
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
278.30
284.00
326.256

60.098

86.683
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

67.0 65.1 63.3 57.2 65.9 66.5

83.9 83.6

82.4 76.1 74.5 83.0 83.2

82.2 73.1 74.4 82.7 82.9
Vehicle Noise: 86.8 85.3 78.0 77.5 85.9 86.1
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

48.0 46.1 44.3 38.3 46.9 47.5

79.0 83.6

77.5 71.2 69.6 78.1 78.3

82.2 73.1 74.4 82.7 82.9
Vehicle Noise: 84.9 83.4 75.3 75.6 84.0 84.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
124
1886
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 145.0
Highway Data
feet
feet
vehicles
Road Elevation: 276.0
Barrier Elevation: 276.0
Pad Elevation: 268.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.65
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 50.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.200 -22.200
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -2.11 -1.20 -14.560 -17.560

3.93 -1.73 -1.20 -12.937 -15.937

55.35 3.96

2.49 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
278.30
284.00
342.943

68.009

64.222
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.6 64.7 63.0 56.9 65.5 66.1

83.1 85.5

81.6 75.3 73.7 82.2 82.4

84.1 75.1 76.3 84.7 84.8
Vehicle Noise: 87.5 86.1 78.3 78.3 86.7 86.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

44.4 42.5 40.8 34.7 43.3 43.9

65.6 69.6

64.1 57.7 56.2 64.6 64.9

68.2 59.1 60.4 68.7 68.9
Vehicle Noise: 71.1 69.6 61.5 61.8 70.2 70.3

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
125
1887
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: First Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 145.0
Highway Data
feet
feet
vehicles
Road Elevation: 276.0
Barrier Elevation: 276.0
Pad Elevation: 268.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.65
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 50.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.200 -22.200
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -2.11 -1.20 -14.560 -17.560

3.93 -1.73 -1.20 -12.937 -15.937

55.35 3.96

2.49 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
278.30
284.00
342.943

68.009

64.222
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.6 64.7 63.0 56.9 65.5 66.1

83.1 85.5

81.6 75.3 73.7 82.2 82.4

84.1 75.1 76.3 84.7 84.8
Vehicle Noise: 87.5 86.1 78.3 78.3 86.7 86.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

44.4 42.5 40.8 34.7 43.3 43.9

65.6 69.6

64.1 57.7 56.2 64.6 64.9

68.2 59.1 60.4 68.7 68.9
Vehicle Noise: 71.1 69.6 61.5 61.8 70.2 70.3

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
126
1888
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Second Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 145.0
Highway Data
feet
feet
vehicles
Road Elevation: 276.0
Barrier Elevation: 276.0
Pad Elevation: 268.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.61
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 50.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.099 -22.099
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -1.90 -1.20 -12.120 -15.120

3.93 -1.51 -1.20 -10.150 -13.150

44.94 1.91

0.95 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
278.30
284.00
340.784

65.850

62.064
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.7 64.8 63.0 57.0 65.6 66.2

83.3 85.8

81.8 75.5 73.9 82.4 82.6

84.3 75.3 76.5 84.9 85.0
Vehicle Noise: 87.8 86.3 78.5 78.5 86.9 87.0
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

44.6 42.7 40.9 34.9 43.5 44.1

68.2 72.6

66.7 60.4 58.8 67.3 67.5

71.2 62.1 63.4 71.8 71.9
Vehicle Noise: 74.0 72.5 64.4 64.7 73.1 73.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
127
1889
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Third Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 145.0
Highway Data
feet
feet
vehicles
Road Elevation: 276.0
Barrier Elevation: 276.0
Pad Elevation: 268.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.59
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 50.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-18.920 -21.920
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -1.84 -1.20 -8.850 -11.850

3.93 -1.45 -1.20 -6.240 -9.240

36.01 0.57

0.13 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
278.30
284.00
340.176

65.242

61.456
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.7 64.8 63.0 57.0 65.6 66.2

83.4 85.8

81.9 75.5 74.0 82.4 82.7

84.4 75.4 76.6 85.0 85.1
Vehicle Noise: 87.8 86.4 78.6 78.5 86.9 87.1
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

44.8 42.9 41.1 35.0 43.7 44.3

71.6 76.6

70.0 63.7 62.1 70.6 70.8

75.2 66.1 67.4 75.7 75.9
Vehicle Noise: 77.8 76.3 68.1 68.5 76.9 77.0

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
128
1890
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Rooftop Balconies
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 145.0
Highway Data
feet
feet
vehicles
Road Elevation: 276.0
Barrier Elevation: 276.0
Pad Elevation: 268.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-12.61
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 50.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-18.731 -21.731
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -1.94 -1.20 -5.200 -8.200

3.93 -3.75 -1.20 0.000 0.000

28.63 0.02
-0.07
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
278.30
284.00
341.174

66.240

87.488
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

66.7 64.8 63.0 56.9 65.6 66.2

83.3 83.5

81.8 75.4 73.9 82.3 82.6

82.1 73.1 74.3 82.7 82.8
Vehicle Noise: 86.5 85.0 77.6 77.2 85.6 85.7
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

44.9 43.0 41.3 35.2 43.8 44.4

75.1 83.5

73.6 67.2 65.7 74.1 74.4

82.1 73.1 74.3 82.7 82.8
Vehicle Noise: 84.1 82.7 74.1 74.9 83.2 83.4

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
129
1891
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Backyard
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.37
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-6.640 -9.640
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.90 -1.20 0.000 0.000
-15.37 -12.90 -1.20 0.000 0.000

0.18 -1.09
-1.16
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
446.617
356.555
356.480
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.3 54.2 50.5 49.1 56.5 56.8

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 58.3 56.2 52.5 51.0 58.5 58.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

49.6 47.6 43.9 42.4 49.9 50.2

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 55.3 53.2 49.5 48.0 55.5 55.8

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
130
1892
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Backyard With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.37
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-6.640 -9.640
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.90 -1.20 0.000 0.000
-15.37 -12.90 -1.20 0.000 0.000

0.18 -1.09
-1.16
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
446.617
356.555
356.480
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.3 54.2 50.5 49.1 56.5 56.8

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 58.3 56.2 52.5 51.0 58.5 58.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

49.6 47.6 43.9 42.4 49.9 50.2

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 55.3 53.2 49.5 48.0 55.5 55.8

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
131
1893
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: First Floor With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.37
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-6.640 -9.640
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.90 -1.20 0.000 0.000
-15.37 -12.90 -1.20 0.000 0.000

0.18 -1.09
-1.16
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
446.617
356.555
356.480
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.3 54.2 50.5 49.1 56.5 56.8

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 58.3 56.2 52.5 51.0 58.5 58.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

49.6 47.6 43.9 42.4 49.9 50.2

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 55.3 53.2 49.5 48.0 55.5 55.8

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
132
1894
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Second Floor With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.45
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0

0.000 0.000
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.91 -1.20 0.000 0.000
-15.37 -12.90 -1.20 0.000 0.000
-0.73
-6.69
-6.90
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
451.938
356.858
356.639
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.2 54.2 50.5 49.0 56.4 56.7

49.8 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.4 51.9 52.2
Vehicle Noise: 58.2 56.2 52.5 51.0 58.4 58.7
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.2 54.2 50.5 49.0 56.4 56.7

49.8 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.4 51.9 52.2
Vehicle Noise: 58.2 56.2 52.5 51.0 58.4 58.7

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
133
1895
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Third Floor With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.53
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0

0.000 0.000
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.92 -1.20 0.000 0.000
-15.37 -12.91 -1.20 0.000 0.000
-2.99
-13.88
-14.23
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
457.525
357.387
357.025
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.1 54.1 50.4 48.9 56.4 56.6

49.8 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.4 51.9 52.2
Vehicle Noise: 58.2 56.1 52.4 50.9 58.4 58.7
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.1 54.1 50.4 48.9 56.4 56.6

49.8 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.4 51.9 52.2
Vehicle Noise: 58.2 56.1 52.4 50.9 58.4 58.7

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
134
1896
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Rooftop Balconies
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.61
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0

0.000 0.000
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.93 -1.20 0.000 0.000
-15.37 -12.92 -1.20 0.000 0.000
-5.69
-21.40
-21.90
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
463.220
358.142
357.637
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.1 54.0 50.3 48.8 56.3 56.6

49.8 51.7

47.8 44.1 42.6 50.1 50.3

49.6 45.9 44.4 51.9 52.2
Vehicle Noise: 58.1 56.1 52.4 50.9 58.3 58.6
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.1 54.0 50.3 48.8 56.3 56.6

49.8 51.7

47.8 44.1 42.6 50.1 50.3

49.6 45.9 44.4 51.9 52.2
Vehicle Noise: 58.1 56.1 52.4 50.9 58.3 58.6

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
135
1897
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Backyard
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.37
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-6.640 -9.640
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.90 -1.20 0.000 0.000
-15.37 -12.90 -1.20 0.000 0.000

0.18 -1.09
-1.16
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
446.617
356.555
356.480
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.3 54.2 50.5 49.1 56.5 56.8

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 58.3 56.2 52.5 51.0 58.5 58.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

49.6 47.6 43.9 42.4 49.9 50.2

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 55.3 53.2 49.5 48.0 55.5 55.8

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
136
1898
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Backyard With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 391.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.37
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 10.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-6.640 -9.640
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -12.90 -1.20 0.000 0.000
-15.37 -12.90 -1.20 0.000 0.000

0.18 -1.09
-1.16
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
446.617
356.555
356.480
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.3 54.2 50.5 49.1 56.5 56.8

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 58.3 56.2 52.5 51.0 58.5 58.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

49.6 47.6 43.9 42.4 49.9 50.2

49.9 51.7

47.8 44.1 42.6 50.1 50.4

49.6 45.9 44.5 51.9 52.2
Vehicle Noise: 55.3 53.2 49.5 48.0 55.5 55.8

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
137
1899
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: First Floor With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 401.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.50
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 20.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-11.400 -14.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -13.08 -1.20 0.000 0.000
-15.37 -13.08 -1.20 0.000 0.000

1.55 -0.54
-0.61
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
456.053
366.594
366.522
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.2 54.1 50.4 48.9 56.4 56.7

49.7 51.5

47.6 43.9 42.4 49.9 50.2

49.5 45.8 44.3 51.7 52.0
Vehicle Noise: 58.1 56.1 52.4 50.9 58.3 58.6
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

44.8 42.7 39.0 37.5 45.0 45.3

49.7 51.5

47.6 43.9 42.4 49.9 50.2

49.5 45.8 44.3 51.7 52.0
Vehicle Noise: 54.2 52.2 48.5 47.0 54.4 54.7

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
138
1900
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Second Floor With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 401.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.56
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 20.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-5.200 -8.200
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -13.09 -1.20 0.000 0.000
-15.37 -13.08 -1.20 0.000 0.000

0.02 -3.96
-4.18
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
459.850
366.889
366.676
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.1 54.1 50.4 48.9 56.3 56.6

49.7 51.5

47.6 43.9 42.4 49.9 50.2

49.5 45.8 44.3 51.7 52.0
Vehicle Noise: 58.1 56.0 52.3 50.8 58.3 58.6
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

50.9 48.9 45.2 43.7 51.1 51.4

49.7 51.5

47.6 43.9 42.4 49.9 50.2

49.5 45.8 44.3 51.7 52.0
Vehicle Noise: 55.5 53.5 49.8 48.3 55.8 56.0

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
139
1901
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Third Floor With Wall
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 401.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.64
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 20.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0

0.000 0.000
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -13.10 -1.20 0.000 0.000
-15.37 -13.09 -1.20 0.000 0.000
-0.59
-9.40
-9.75
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
465.391
367.404
367.052
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.0 54.0 50.3 48.8 56.2 56.5

49.7 51.5

47.6 43.9 42.4 49.9 50.2

49.5 45.8 44.3 51.7 52.0
Vehicle Noise: 58.0 56.0 52.3 50.8 58.2 58.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

56.0 54.0 50.3 48.8 56.2 56.5

49.7 51.5

47.6 43.9 42.4 49.9 50.2

49.5 45.8 44.3 51.7 52.0
Vehicle Noise: 58.0 56.0 52.3 50.8 58.2 58.5

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
140
1902
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: Tustin Ave.

Scenario: Rooftop Balconies
39,400

10.00%
381.0

NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 3,940 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 401.0
Highway Data
feet
feet
vehicles
Road Elevation: 259.0
Barrier Elevation: 263.8
Pad Elevation: 263.8
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 66 feet
REMEL Traffic Flow Distance

4.50 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 75.0% 8.0% 17.0% 97.00%

75.0% 8.0% 17.0% 2.00%

75.0% 8.0% 17.0% 1.00%
-14.71
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 20.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0

0.000 0.000
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType
-12.36 -13.11 -1.20 0.000 0.000
-15.37 -13.10 -1.20 0.000 0.000
-2.23
-15.78
-16.27
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
261.30
267.00
470.991
368.138
367.647
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

55.9 53.9 50.2 48.7 56.2 56.5

49.6 51.5

47.6 43.9 42.4 49.9 50.2

49.4 45.7 44.3 51.7 52.0
Vehicle Noise: 58.0 55.9 52.2 50.7 58.2 58.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

55.9 53.9 50.2 48.7 56.2 56.5

49.6 51.5

47.6 43.9 42.4 49.9 50.2

49.4 45.7 44.3 51.7 52.0
Vehicle Noise: 58.0 55.9 52.2 50.7 58.2 58.5

76.31 81.16

67.36 Road Grade: 1.0%
feet
Friday, October 10, 2025
141
1903
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 203.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.37
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 108.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-19.300 -22.300
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -7.21 -1.20 0.000 0.000

3.93 -7.22 -1.20 0.000 0.000

71.96 -0.01
-0.31
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
383.212
148.842
149.151
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.9 64.0 62.2 56.2 64.8 65.4

78.0 80.0

76.5 70.2 68.6 77.1 77.3

78.6 69.6 70.8 79.2 79.3
Vehicle Noise: 82.3 80.8 73.3 73.0 81.4 81.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

46.6 44.7 42.9 36.9 45.5 46.1

78.0 80.0

76.5 70.2 68.6 77.1 77.3

78.6 69.6 70.8 79.2 79.3
Vehicle Noise: 82.2 80.7 72.9 72.9 81.3 81.4

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
142
1904
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 203.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.62
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 108.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -6.05 -1.20 -13.054 -16.054

3.93 -5.85 -1.20 -10.860 -13.860

86.71 2.58

1.28 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
398.479
124.545
120.758
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.7 63.8 62.0 55.9 64.6 65.2

79.2 81.4

77.7 71.3 69.8 78.2 78.5

80.0 71.0 72.2 80.6 80.7
Vehicle Noise: 83.5 82.1 74.4 74.2 82.6 82.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.3 41.4 39.6 33.5 42.2 42.8

63.1 67.6

61.6 55.3 53.7 62.2 62.4

66.1 57.1 58.4 66.7 66.8
Vehicle Noise: 68.9 67.5 59.3 59.6 68.0 68.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
143
1905
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: First Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 203.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.62
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 108.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -6.05 -1.20 -13.054 -16.054

3.93 -5.85 -1.20 -10.860 -13.860

86.71 2.58

1.28 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
398.479
124.545
120.758
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.7 63.8 62.0 55.9 64.6 65.2

79.2 81.4

77.7 71.3 69.8 78.2 78.5

80.0 71.0 72.2 80.6 80.7
Vehicle Noise: 83.5 82.1 74.4 74.2 82.6 82.8
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.3 41.4 39.6 33.5 42.2 42.8

63.1 67.6

61.6 55.3 53.7 62.2 62.4

66.1 57.1 58.4 66.7 66.8
Vehicle Noise: 68.9 67.5 59.3 59.6 68.0 68.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
144
1906
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Second Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 203.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.61
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 108.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.350 -22.350
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -5.99 -1.20 -11.520 -14.520

3.93 -5.79 -1.20 -9.120 -12.120

78.04 1.61

0.64 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
397.453
123.519
119.732
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.7 63.8 62.0 55.9 64.6 65.2

79.2 81.5

77.7 71.4 69.8 78.3 78.5

80.1 71.0 72.3 80.6 80.7
Vehicle Noise: 83.6 82.1 74.5 74.3 82.7 82.9
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.3 41.4 39.7 33.6 42.2 42.8

64.7 69.4

63.2 56.9 55.3 63.8 64.0

67.9 58.9 60.1 68.5 68.6
Vehicle Noise: 70.6 69.2 61.0 61.4 69.8 69.9

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
145
1907
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Third Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 203.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.60
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 108.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.300 -22.300
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -5.98 -1.20 -9.910 -12.910

3.93 -5.78 -1.20 -6.870 -9.870

70.03 0.87

0.21 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
397.170
123.236
119.449
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.7 63.8 62.0 56.0 64.6 65.2

79.3 81.5

77.8 71.4 69.8 78.3 78.5

80.1 71.0 72.3 80.6 80.8
Vehicle Noise: 83.6 82.1 74.5 74.3 82.7 82.9
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.4 41.5 39.7 33.7 42.3 42.9

66.3 71.6

64.8 58.5 56.9 65.4 65.6

70.2 61.2 62.4 70.8 70.9
Vehicle Noise: 72.8 71.3 63.1 63.5 71.9 72.0

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
146
1908
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Rooftop Balconies
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 203.0
Highway Data
feet
feet
vehicles
Road Elevation: 275.0
Barrier Elevation: 275.0
Pad Elevation: 267.1
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.61
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 108.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.227 -22.227
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -6.00 -1.20 -7.750 -10.750

3.93 -5.80 -1.20 -5.200 -8.200

62.71 0.35

0.02 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
277.30
283.00
397.636
123.701
119.915
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.7 63.8 62.0 55.9 64.6 65.2

79.2 81.5

77.7 71.4 69.8 78.3 78.5

80.0 71.0 72.3 80.6 80.7
Vehicle Noise: 83.6 82.1 74.5 74.3 82.7 82.9
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

43.4 41.5 39.8 33.7 42.3 42.9

68.5 73.3

67.0 60.6 59.1 67.5 67.8

71.8 62.8 64.1 72.4 72.5
Vehicle Noise: 74.5 73.1 64.9 65.3 73.6 73.8

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
147
1909
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 233.0
Highway Data
feet
feet
vehicles
Road Elevation: 274.0
Barrier Elevation: 274.0
Pad Elevation: 266.4
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-13.85
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 138.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -8.45 -1.20 0.000 0.000

3.93 -8.46 -1.20 0.000 0.000

85.30 -0.01
-0.38
Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
276.30
282.00
412.198
180.030
180.276
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.4 63.5 61.8 55.7 64.3 64.9

76.8 78.8

75.3 68.9 67.4 75.8 76.1

77.4 68.4 69.6 78.0 78.1
Vehicle Noise: 81.0 79.6 72.1 71.7 80.2 80.3
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

46.0 44.1 42.4 36.3 44.9 45.5

76.8 78.8

75.3 68.9 67.4 75.8 76.1

77.4 68.4 69.6 78.0 78.1
Vehicle Noise: 80.9 79.5 71.7 71.6 80.0 80.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
148
1910
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Backyard With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 233.0
Highway Data
feet
feet
vehicles
Road Elevation: 274.0
Barrier Elevation: 274.0
Pad Elevation: 266.4
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-14.08
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 138.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -7.44 -1.20 -12.677 -15.677

3.93 -7.28 -1.20 -10.380 -13.380

99.75 2.29

1.04 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
276.30
282.00
427.160
154.225
150.438
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.2 63.3 61.5 55.5 64.1 64.7

77.8 80.0

76.3 69.9 68.4 76.8 77.1

78.6 69.5 70.8 79.1 79.3
Vehicle Noise: 82.1 80.7 73.1 72.8 81.2 81.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

42.8 40.9 39.1 33.1 41.7 42.3

62.1 66.6

60.6 54.3 52.7 61.2 61.4

65.2 56.2 57.4 65.8 65.9
Vehicle Noise: 67.9 66.5 58.4 58.7 67.1 67.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
149
1911
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: First Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 233.0
Highway Data
feet
feet
vehicles
Road Elevation: 274.0
Barrier Elevation: 274.0
Pad Elevation: 266.4
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-14.08
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 138.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -7.44 -1.20 -12.677 -15.677

3.93 -7.28 -1.20 -10.380 -13.380

99.75 2.29

1.04 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
276.30
282.00
427.160
154.225
150.438
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.2 63.3 61.5 55.5 64.1 64.7

77.8 80.0

76.3 69.9 68.4 76.8 77.1

78.6 69.5 70.8 79.1 79.3
Vehicle Noise: 82.1 80.7 73.1 72.8 81.2 81.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

42.8 40.9 39.1 33.1 41.7 42.3

62.1 66.6

60.6 54.3 52.7 61.2 61.4

65.2 56.2 57.4 65.8 65.9
Vehicle Noise: 67.9 66.5 58.4 58.7 67.1 67.2

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
150
1912
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Second Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 233.0
Highway Data
feet
feet
vehicles
Road Elevation: 274.0
Barrier Elevation: 274.0
Pad Elevation: 266.4
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 14.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-14.07
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 138.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -7.41 -1.20 -11.380 -14.380

3.93 -7.25 -1.20 -8.800 -11.800

91.68 1.54

0.56 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
276.30
282.00
426.374
153.439
149.653
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.2 63.3 61.5 55.5 64.1 64.7

77.8 80.0

76.3 70.0 68.4 76.9 77.1

78.6 69.6 70.8 79.2 79.3
Vehicle Noise: 82.2 80.7 73.1 72.9 81.3 81.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

42.8 40.9 39.1 33.1 41.7 42.3

63.5 68.2

61.9 55.6 54.0 62.5 62.7

66.8 57.8 59.0 67.4 67.5
Vehicle Noise: 69.5 68.0 59.9 60.2 68.6 68.8

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
151
1913
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Third Floor With Wall
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 233.0
Highway Data
feet
feet
vehicles
Road Elevation: 274.0
Barrier Elevation: 274.0
Pad Elevation: 266.4
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 23.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-14.06
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 138.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.400 -22.400
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -7.40 -1.20 -10.090 -13.090

3.93 -7.24 -1.20 -7.010 -10.010

84.11 0.93

0.23 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
276.30
282.00
426.172
153.237
149.451
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.2 63.3 61.5 55.5 64.1 64.7

77.8 80.0

76.3 70.0 68.4 76.9 77.1

78.6 69.6 70.8 79.2 79.3
Vehicle Noise: 82.2 80.7 73.1 72.9 81.3 81.5
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

42.8 40.9 39.1 33.1 41.7 42.3

64.7 70.0

63.2 56.9 55.3 63.8 64.0

68.6 59.6 60.8 69.2 69.3
Vehicle Noise: 71.2 69.7 61.5 61.9 70.3 70.4

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
152
1914
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (CALVENO) - v5/13/24

SITE SPECIFIC INPUT DATA
Project Name: Best Buy Orange
Job Number: 16438
Analyst: N. Johnson
Road Name: SR-55
Scenario: Rooftop Balconies
211,000

10.00%

95.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):

Peak Hour Percentage:

Peak Hour Volume: 21,100 vehicles
Centerline Dist. to Barrier:

Centerline Dist. to Observer: 233.0
Highway Data
feet
feet
vehicles
Road Elevation: 274.0
Barrier Elevation: 274.0
Pad Elevation: 266.4
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 14.0
Observer Height (Above Pad): 32.0 feet
feet
Vehicle Speed: 60 mph
Near/Far Lane Distance: 94 feet
REMEL Traffic Flow Distance

6.28 VehicleType Day Evening Night Daily
Medium Trucks:

Heavy Trucks:

Autos: 77.5% 12.9% 9.6% 41.00%

84.8% 4.9% 10.3% 35.17%

86.5% 2.7% 10.8% 23.83%
-14.07
Finite Road
-1.20
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 138.0 feet
Barrier Type (0-Wall, 1-Berm): 14.0
-19.350 -22.350
Fresnel Berm Atten
Medium Trucks:

Heavy Trucks:

Autos:

VehicleType

5.62 -7.42 -1.20 -8.400 -11.400

3.93 -7.25 -1.20 -5.400 -8.400

77.04 0.48

0.04 Medium Trucks:

Heavy Trucks:

Autos:

Noise Source Elevations (in feet)
Medium Trucks:

Heavy Trucks:

Autos: 0.00
276.30
282.00
426.556
153.622
149.835
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

65.2 63.3 61.5 55.5 64.1 64.7

77.8 80.0

76.3 70.0 68.4 76.9 77.1

78.6 69.6 70.8 79.2 79.3
Vehicle Noise: 82.2 80.7 73.1 72.9 81.3 81.4
Mitigated Noise Levels (with Topo and barrier attenuation) Medium Trucks:

Heavy Trucks:

Autos:

VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL

42.9 41.0 39.2 33.1 41.8 42.4

66.4 71.6

64.9 58.6 57.0 65.5 65.7

70.2 61.2 62.4 70.8 70.9
Vehicle Noise: 72.8 71.3 63.1 63.5 71.9 72.0

80.82 84.54

74.19 Road Grade: 1.0%
feet
Friday, October 10, 2025
153
1915
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
154
1916
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
APPENDIX 7.2:

INTERIOR NOISE LEVEL REDUCTION CALCULATIONS
155
1917
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
156
1918

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 2 Analyst: N. Johnso
Room: Den
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 266.0 44 25 42 44 46 49 54 0.8412 0.0168 0.0106 0.0067 0.0033 0.0011Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 40.0 33 23 24 29 34 37 37 0.2005 0.1592 0.0504 0.0159 0.0080 0.0080 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 306 0.0034 0.0006 0.0002 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 24.68 32.40 37.01 41.31 44.31 45.30(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 288.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 43.20 48.96 34.56 92.2 149.8 86.4Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 288.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 28.80 23.04 14.40 8.64 8.64 8.64Walls - Drywall David Harris p. 348 612.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 61.20 48.96 30.60 18.36 18.36 18.36Totals 1188 133.2 120.96 79.56 119.16 176.76 113.4 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.61 -4.03 -5.85 -4.10 -2.38 -4.31(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.07 22.37 25.16 31.22 35.93 34.98Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.17 30.97 28.36 31.22 34.73 33.98Noise Reduction (dBA) 31.04 30.85 28.23 31.09 34.61 33.86 157
1919

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 2 Analyst: N. Johnso
Room: Living
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 284.0 46 27 42 44 46 49 54 0.5667 0.0179 0.0113 0.0071 0.0036 0.0011Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 40.0 33 23 24 29 34 37 37 0.2005 0.1592 0.0504 0.0159 0.0080 0.0080 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 324 0.0024 0.0005 0.0002 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 26.26 32.62 37.21 41.48 44.48 45.51(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 323.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 48.45 54.91 38.76 103.36 168.0 96.90Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 323.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 32.30 25.84 16.15 9.69 9.69 9.69Walls - Drywall David Harris p. 348 648.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 64.80 51.84 32.40 19.44 19.44 19.44Totals 1294 145.55 132.59 87.31 132.49 197.09 126.03 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.48 -3.88 -5.69 -3.88 -2.16 -4.10(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 16.78 22.74 25.51 31.59 36.32 35.41Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 32.88 31.34 28.71 31.59 35.12 34.41Noise Reduction (dBA) 32.76 31.22 28.59 31.47 34.99 34.28 158
1920

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 2 Analyst: N. Johnso
Room: Bdrm. 1
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 222.0 46 27 42 44 46 49 54 0.4429 0.0140 0.0088 0.0056 0.0028 0.0009Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 30.0 33 23 24 29 34 37 37 0.1504 0.1194 0.0378 0.0119 0.0060 0.0060 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 252 0.0024 0.0005 0.0002 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 26.28 32.76 37.33 41.58 44.58 45.64(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 195.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 29.3 33.2 23.4 62.4 101.4 58.5Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 195.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 19.50 15.60 9.75 5.85 5.85 5.85Walls - Drywall David Harris p. 348 504.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 50.40 40.32 25.20 15.12 15.12 15.12Totals 894 99.15 89.07 58.35 83.37 122.37 79.47 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.05 -4.52 -6.35 -4.80 -3.14 -5.01(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 16.23 22.24 24.98 30.77 35.44 34.63Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 32.33 30.84 28.18 30.77 34.24 33.63Noise Reduction (dBA) 32.21 30.72 28.05 30.65 34.12 33.51 159
1921

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 4 Analyst: N. Johnso
Room: Bdrm. 2
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 192.0 46 27 42 44 46 49 54 0.3831 0.0121 0.0076 0.0048 0.0024 0.0008Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows Harris pg.5.66 24.0 38 29 33 36 37 41 51 0.0302 0.0120 0.0060 0.0048 0.0019 0.0002 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 216 0.0019 0.0001 0.0001 0.0000 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 27.18 39.52 41.99 43.52 46.99 53.54(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 143.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 21.45 24.31 17.16 45.76 74.36 42.90Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 143.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 14.30 11.44 7.15 4.29 4.29 4.29Walls - Drywall David Harris p. 348 432.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 43.20 34.56 21.60 12.96 12.96 12.96Totals 718 78.95 70.31 45.91 63.01 91.61 60.15 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.37 -4.87 -6.73 -5.35 -3.73 -5.55(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 16.81 28.64 29.26 32.17 37.26 41.99Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 32.91 37.24 32.46 32.17 36.06 40.99Noise Reduction (dBA) 32.79 37.12 32.34 32.04 35.94 40.87 160
1922

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 2 Analyst: N. Johnso
Room: Den
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 266.0 44 25 42 44 46 49 54 0.8412 0.0168 0.0106 0.0067 0.0033 0.0011Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 40.0 27 21 17 25 32 37 38 0.3177 0.7981 0.1265 0.0252 0.0080 0.0063 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 306 0.0038 0.0027 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 24.22 25.75 33.49 39.82 44.31 46.17(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 288.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 43.20 48.96 34.56 92.2 149.8 86.4Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 288.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 28.80 23.04 14.40 8.64 8.64 8.64Walls - Drywall David Harris p. 348 612.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 61.20 48.96 30.60 18.36 18.36 18.36Totals 1188 133.2 120.96 79.56 119.16 176.76 113.4 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.61 -4.03 -5.85 -4.10 -2.38 -4.31(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 14.60 15.72 21.64 29.72 35.93 35.85Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 30.70 24.32 24.84 29.72 34.73 34.85Noise Reduction (dBA) 30.58 24.19 24.71 29.60 34.61 34.73 161
1923

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 2 Analyst: N. Johnso
Room: Living
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 284.0 46 27 42 44 46 49 54 0.5667 0.0179 0.0113 0.0071 0.0036 0.0011Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 40.0 27 21 17 25 32 37 38 0.3177 0.7981 0.1265 0.0252 0.0080 0.0063 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 324 0.0027 0.0025 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.64 25.99 33.71 40.00 44.48 46.37(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 323.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 48.45 54.91 38.76 103.36 168.0 96.90Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 323.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 32.30 25.84 16.15 9.69 9.69 9.69Walls - Drywall David Harris p. 348 648.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 64.80 51.84 32.40 19.44 19.44 19.44Totals 1294 145.55 132.59 87.31 132.49 197.09 126.03 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.48 -3.88 -5.69 -3.88 -2.16 -4.10(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 16.16 16.11 22.02 30.12 36.32 36.27Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 32.26 24.71 25.22 30.12 35.12 35.27Noise Reduction (dBA) 32.14 24.58 25.09 30.00 34.99 35.15 162
1924

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 2 Analyst: N. Johnso
Room: Bdrm. 1
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 222.0 46 27 42 44 46 49 54 0.4429 0.0140 0.0088 0.0056 0.0028 0.0009Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 30.0 27 21 17 25 32 37 38 0.2383 0.5986 0.0949 0.0189 0.0060 0.0048 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 252 0.0027 0.0024 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.68 26.14 33.86 40.12 44.58 46.50(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 195.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 29.3 33.2 23.4 62.4 101.4 58.5Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 195.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 19.50 15.60 9.75 5.85 5.85 5.85Walls - Drywall David Harris p. 348 504.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 50.40 40.32 25.20 15.12 15.12 15.12Totals 894 99.15 89.07 58.35 83.37 122.37 79.47 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.05 -4.52 -6.35 -4.80 -3.14 -5.01(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.63 15.63 21.50 29.32 35.44 35.49Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.73 24.23 24.70 29.32 34.24 34.49Noise Reduction (dBA) 31.60 24.10 24.58 29.19 34.12 34.37 163
1925

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 3 Analyst: N. Johnso
Room: Bdrm. 4
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 192.0 46 27 42 44 46 49 54 0.3831 0.0121 0.0076 0.0048 0.0024 0.0008Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 24.0 27 21 17 25 32 37 38 0.1906 0.4789 0.0759 0.0151 0.0048 0.0038 Glass Doors Milgard 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 216 0.0027 0.0023 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.76 26.43 34.13 40.34 44.77 46.75(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 140.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 21.00 23.80 16.80 44.80 72.80 42.00Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 140.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 14.00 11.20 7.00 4.20 4.20 4.20Walls - Drywall David Harris p. 348 432.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 43.20 34.56 21.60 12.96 12.96 12.96Totals 712 78.2 69.56 45.4 61.96 89.96 59.16 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.41 -4.92 -6.77 -5.42 -3.80 -5.62(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.34 15.51 21.35 28.92 34.96 35.12Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.44 24.11 24.55 28.92 33.76 34.12Noise Reduction (dBA) 31.32 23.99 24.43 28.79 33.64 34.00 164
1926

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 3 Analyst: N. Johnso
Room: Kitchen
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 245.0 46 27 42 44 46 49 54 0.4888 0.0155 0.0098 0.0062 0.0031 0.0010Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 16.0 27 21 17 25 32 37 38 0.1271 0.3192 0.0506 0.0101 0.0032 0.0025 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 261 0.0024 0.0013 0.0002 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 26.27 28.92 36.36 42.06 46.19 48.71(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 198.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 29.70 33.66 23.76 63.36 102.96 59.40Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 198.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 19.80 15.84 9.90 5.94 5.94 5.94Walls - Drywall David Harris p. 348 522.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 52.20 41.76 26.10 15.66 15.66 15.66Totals 918 101.7 91.26 59.76 84.96 124.56 81 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.09 -4.56 -6.40 -4.87 -3.21 -5.08(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 16.18 18.36 23.96 31.18 36.98 37.63Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 32.28 26.96 27.16 31.18 35.78 36.63Noise Reduction (dBA) 32.15 26.83 27.03 31.06 35.65 36.51 165
1927

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 3 Analyst: N. Johnso
Room: Bdrm. 3
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 191.0 46 27 42 44 46 49 54 0.3811 0.0121 0.0076 0.0048 0.0024 0.0008Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 16.0 27 21 17 25 32 37 38 0.1271 0.3192 0.0506 0.0101 0.0032 0.0025 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 207 0.0025 0.0016 0.0003 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 26.10 27.96 35.51 41.43 45.68 47.98(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 132.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 19.80 22.44 15.84 42.24 68.64 39.60Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 132.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 13.20 10.56 6.60 3.96 3.96 3.96Walls - Drywall David Harris p. 348 414.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 41.40 33.12 20.70 12.42 12.42 12.42Totals 678 74.4 66.12 43.14 58.62 85.02 55.98 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.44 -4.96 -6.81 -5.48 -3.86 -5.68(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.66 17.00 22.70 29.95 35.82 36.30Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.76 25.60 25.90 29.95 34.62 35.30Noise Reduction (dBA) 31.63 25.48 25.77 29.83 34.49 35.18 166
1928

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 4 Analyst: N. Johnso
Room: Den
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 218.0 46 27 42 44 46 49 54 0.4350 0.0138 0.0087 0.0055 0.0027 0.0009Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 35.0 27 21 17 25 32 37 38 0.2780 0.6983 0.1107 0.0221 0.0070 0.0055 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows Milgard 35.0 27 21 15 25 35 41 28 0.2780 1.1068 0.1107 0.0111 0.0028 0.0028

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 288 0.0034 0.0063 0.0008 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 24.63 22.00 30.98 38.72 43.62 44.96(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 255.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 38.25 43.35 30.60 81.60 132.60 76.50Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 255.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 25.50 20.40 12.75 7.65 7.65 7.65Walls - Drywall David Harris p. 348 576.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 57.60 46.08 28.80 17.28 17.28 17.28Totals 1086 121.35 109.83 72.15 106.53 157.53 101.43Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.75 -4.19 -6.01 -4.32 -2.62 -4.53(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00 (4) Calculated Interior Noise Reduction (dBA)
125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 14.88 11.81 18.96 28.41 35.00 34.43Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 30.98 20.41 22.16 28.41 33.80 33.43Noise Reduction (dBA) 30.85 20.28 22.04 28.28 33.68 33.30 167
1929

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 4 Analyst: N. Johnso
Room: Kitchen
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 191.0 46 27 42 44 46 49 54 0.3811 0.0121 0.0076 0.0048 0.0024 0.0008Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 16.0 27 21 17 25 32 37 38 0.1271 0.3192 0.0506 0.0101 0.0032 0.0025 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 207 0.0025 0.0016 0.0003 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 26.10 27.96 35.51 41.43 45.68 47.98(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 130.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 19.50 22.10 15.60 41.60 67.60 39.00Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 130.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 13.00 10.40 6.50 3.90 3.90 3.90Walls - Drywall David Harris p. 348 414.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 41.40 33.12 20.70 12.42 12.42 12.42Totals 674 73.9 65.62 42.8 57.92 83.92 55.32 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.47 -4.99 -6.85 -5.53 -3.92 -5.73(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.63 16.97 22.67 29.90 35.76 36.25Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.73 25.57 25.87 29.90 34.56 35.25Noise Reduction (dBA) 31.60 25.44 25.74 29.77 34.43 35.12 168
1930

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 4 Analyst: N. Johnso
Room: Bdrm. 2
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 192.0 46 27 42 44 46 49 54 0.3831 0.0121 0.0076 0.0048 0.0024 0.0008Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 24.0 27 21 17 25 32 37 38 0.1906 0.4789 0.0759 0.0151 0.0048 0.0038 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 216 0.0027 0.0023 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.76 26.43 34.13 40.34 44.77 46.75(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 143.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 21.45 24.31 17.16 45.76 74.36 42.90Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 143.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 14.30 11.44 7.15 4.29 4.29 4.29Walls - Drywall David Harris p. 348 432.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 43.20 34.56 21.60 12.96 12.96 12.96Totals 718 78.95 70.31 45.91 63.01 91.61 60.15 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -4.37 -4.87 -6.73 -5.35 -3.73 -5.55(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.39 15.56 21.40 28.99 35.04 35.19Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.49 24.16 24.60 28.99 33.84 34.19Noise Reduction (dBA) 31.36 24.03 24.48 28.87 33.72 34.07 169
1931

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 5 Analyst: N. Johnso
Room: Den
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 258.0 46 27 42 44 46 49 54 0.5148 0.0163 0.0103 0.0065 0.0032 0.0010Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 30.0 27 21 17 25 32 37 38 0.2383 0.5986 0.0949 0.0189 0.0060 0.0048 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 288 0.0026 0.0021 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.83 26.71 34.38 40.54 44.94 46.97(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 255.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 38.25 43.35 30.60 81.60 132.60 76.50Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 255.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 25.50 20.40 12.75 7.65 7.65 7.65Walls - Drywall David Harris p. 348 576.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 57.60 46.08 28.80 17.28 17.28 17.28Totals 1086 121.35 109.83 72.15 106.53 157.53 101.43 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.75 -4.19 -6.01 -4.32 -2.62 -4.53(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 16.07 16.52 22.36 30.22 36.32 36.44Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 32.17 25.12 25.56 30.22 35.12 35.44Noise Reduction (dBA) 32.05 24.99 25.44 30.10 34.99 35.32 170
1932

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 5 Analyst: N. Johnso
Room: Living
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 248.0 46 27 42 44 46 49 54 0.4948 0.0156 0.0099 0.0062 0.0031 0.0010Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 40.0 27 21 17 25 32 37 38 0.3177 0.7981 0.1265 0.0252 0.0080 0.0063 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 288 0.0028 0.0028 0.0005 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.50 25.49 33.25 39.62 44.14 45.94(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 255.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 38.25 43.35 30.60 81.60 132.60 76.50Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 255.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 25.50 20.40 12.75 7.65 7.65 7.65Walls - Drywall David Harris p. 348 576.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 57.60 46.08 28.80 17.28 17.28 17.28Totals 1086 121.35 109.83 72.15 106.53 157.53 101.43 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.75 -4.19 -6.01 -4.32 -2.62 -4.53(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.74 15.30 21.24 29.30 35.52 35.41Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.84 23.90 24.44 29.30 34.32 34.41Noise Reduction (dBA) 31.72 23.78 24.31 29.17 34.19 34.29 171
1933

INTERIOR NOISE REDUCTIONS
Project Name: Best Buy Orange Job Number: 16438
Floor Plan: Plan 5 Analyst: N. Johnso
Room: Bdrm. 1
(1) Transmission Loss Calculations (Exterior Wall)
Transmission Loss (dB) by Frequency (Hz) Fractional Area S/(10^(TL/10)) Exterior Wall Wall
Assembly Source Area STC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Standard David Harris p. 371 240.0 46 27 42 44 46 49 54 0.4789 0.0151 0.0096 0.0060 0.0030 0.0010Slider Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Hung Windows ABC 30.0 27 21 17 25 32 37 38 0.2383 0.5986 0.0949 0.0189 0.0060 0.0048 Glass Doors 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Fixed Windows 0.0 0000000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000

0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Totals 270 0.0027 0.0023 0.0004 0.0001 0.0000 0.0000
Composite Exterior Wall Sound Transmission Loss 10*LOG(1/t) 25.76 26.43 34.13 40.34 44.77 46.75(2) Room Effects (Absorption) Absorption Coefficients by Frequency (Hz) Absorption (Sabins) Room Surface/
Material Source Area NRC 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000 Floor - Carpet David Harris p. 347 221.0 0.30 0.15 0.17 0.12 0.32 0.52 0.30 33.15 37.57 26.52 70.72 114.92 66.30Floor - Vinyl David Harris p. 347 0.0 0.05 0.02 0.03 0.05 0.03 0.03 0.02 0.00 0.00 0.00 0.00 0.00 0.00Ceiling - Drywall David Harris p. 348 221.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 22.10 17.68 11.05 6.63 6.63 6.63Walls - Drywall David Harris p. 348 540.0 0.50 0.10 0.08 0.05 0.03 0.03 0.03 54.00 43.20 27.00 16.20 16.20 16.20Totals 982 109.25 98.45 64.57 93.55 137.75 89.13 Room Effect 10*log (Room Absorption in Sabins)/(Exterior Wall Area) -3.93 -4.38 -6.21 -4.60 -2.92 -4.81(3) Adjustment FactorSound Source Adjustment Factor -6.00 -6.00 -6.00 -6.00 -6.00 -6.00(4) Calculated Interior Noise Reduction (dBA) 125 250 500 1000 2000 4000
(Transmission Loss + Room Effects + Adjustment Factor) 15.83 16.05 21.91 29.74 35.85 35.93Octave Band Frequency Correction Factors for A-Weighted Sound Levels 16.10 8.60 3.20 0.00 -1.20 -1.00A-Weighted Sound Levels 31.93 24.65 25.11 29.74 34.65 34.93Noise Reduction (dBA) 31.80 24.53 24.99 29.61 34.52 34.81 172
1934
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
173
1935
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
APPENDIX 9.1:

HVAC
174
1936
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
175
1937
Product Data
This unit has been designed utilizing Carrier’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.

NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up-to-date ratings information.

Industry leading
Features / Benefits
Efficiency
• 13.4 - 16.0 SEER2 (13.5 - 16.5 SEER) /

11.0 – 13.5 EER2 (11.0 - 14.5 EER)
• Microtube Technology refrigeration system
• Indoor air quality accessories available
Reliability
• Puron refrigerant - environmentally sound, won’t deplete the ozone layer and low lifetime service cost.
• Scroll compressor
• Internal pressure relief valve
• Internal thermal overload
• Filter drier
Durability
WeatherArmor™ Protection Package:
• Solid, durable sheet metal construction
• Dense wire coil guard
Applications
• Long–line – up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.4 m) evaporator above condenser (See Long Line Guide for more information.)
• Low ambient cooling (down to 0°F / -18°C ) with approved low ambient accessory kits.
24SCA4
Comfort™ Series Single-Stage Air Conditioner
with Puron® Refrigerant
1-1/2 To 5 Tons

STANDARD FEATURES
Features 18 24 30 36 42 48 60
Puron Refrigerant X X X X X X X
SEER2 (Range depending on indoor combination) 13.4 - 16.0 13.4 - 16.0 13.4 - 16.0 13.4 - 15.0 13.4 - 15.5 13.4 - 15.2 13.4 - 14.0 Scroll Compressor X X X X X X X
Field Installed Filter Drier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line Capability X X X X X X X
Low Ambient Capability with Kit X X X X X X X
176
1938
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 2 Model Number Nomenclature
1 2 3 4 5 6 7 8 9 10 11 12

N N A A A/N N N N A/N A/N A/N N
2 4 S C A 4 1 8 N 0 0 3
Product Series Design Type Tier Major
Series SEER2 Cooling
Capacity Region Feature Special Feature Voltage
24 = R-410A
AC
S = Single
Stage AC C = Comfort Series A=Initial 4 = 13.4 SEER2 1,000 Btuh (nominal)
N = Standard
North AC 0=Standard 0=Standard 3=208/230-1

CATALOG ORDERING NUMBERS
Size Model Number
18 24SCA418N003
24 24SCA424N003
30 24SCA430N003
36 24SCA436N003
42 24SCA442N003
48 24SCA448N003
60 24SCA460N003
Physical Data
UNIT SIZE 18 24 30 36 42 48 60
Compressor Type Scroll
REFRIGERANT Puron® (R-410A)
Control TXV (Puron Hard Shutoff)
Factory Charge lb (kg)*
*.For 15 ft. lineset

5.5 (2.49) 4.40 (2.00) 6.00 (2.72) 5.20 (2.36) 7.90 (3.58) 8.90 (4.04) 9.10 (4.13) COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1600 1800 2500 2750 4100 3850 4000
Motor HP 1/12 1/12 1/10 1/5 1/4 1/4 1/4
Motor RPM 1100 1100 1100 1100 1100 1100 1100

COND COIL
Face Area (Sq ft) 8.4 9.8 17.1 12.9 23.6 15.0 19.3
Fins per In. 25 25 25 20 25 20 20
Rows 1 1 1 1 1 2 2
Circuits 3 5 4 5 7 6 9
VALVE CONNECT. (In. ID)
Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8
Liquid 3/8"
REFRIGERANT TUBES* (In. OD)
Rated Vapor†
†.Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8
Rated Liquid Line‡
‡.See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.

Note: See unit Installation Instruction for proper installation. 3/8"
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
®
Quality
ISO 9001
177
1939
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 3 REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengths for Cooling Only Systems with Puron® Refrigerant:

The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units.

See Table below for liquid line sizing and maximum lengths :
-- = outside acceptable range
Table 1 – Maximum Total Equivalent Length*
Outdoor Unit BELOW Indoor Unit
*.Maximum actual length not to exceed 200 ft (61 m)
Size Liquid Line
Connection
Liquid
Line Diam.
w/ TXV
AC with Puron Refrigerant Maximum Total Equivalent Length†: Outdoor unit BELOW Indoor Vertical Separation ft (m)
†.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. 0-5
(0-1.5)
6-10
(1.8-3.0)
11-20
(3.4-6.1)
21-30
(6.4-9.1)
31-40
(9.4-12.2)
41-50
(12.5-15.2)
51-60
(15.5-18.3)
61-70
(18.6-21.3)
71-80
(21.6-24.4)
18000 3/8
1/4 150 150 125 100 100 75 -- -- --
5/16 250* 250* 250* 250* 250* 250* 250* 225* 150
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
24000 3/8
1/4 75 75 75 50 50 -- -- -- --
5/16 250* 250* 250* 250* 250* 225* 175 125 100
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
30000 3/8
1/4 30 -- -- -- -- -- -- -- --
5/16 175 225* 200 175 125 100 75 -- --
3/8 250* 250* 250* 250* 250* 250* 250* 250* 250*
36000 3/8 5/16 175 150 150 100 100 100 75 -- --
3//8 250* 250* 250* 250* 250* 250* 250* 250* 250*
42000 3/8 5/16 125 100 100 75 75 50 -- -- --
3/8 250* 250* 250* 250* 250* 250* 250* 250* 150
48000 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 --
60000 3/8 3/8 250* 250* 250* 225* 190 150 110 -- --
Table 2 – Maximum* Total Equivalent Length
Outdoor Unit ABOVE Indoor Unit
*.Maximum actual length not to exceed 200 ft (61 m)
Size Liquid Line
Connection
Liquid Line
Diam.
w/ TXV
AC with Puron Refrigerant Maximum Total Equivalent Length†: Outdoor unit ABOVE Indoor Vertical Separation ft (m)
†.Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = Outside acceptable range
25 (7.6)
26-50
(7.9-15.2)
51-75
(15.5-22.9)
76-100
(23.2-30.5)
101-125
(30.8-38.1)
126-150
(38.4-45.7)
151-175
(46.0-53.3)
176-200
(53.6-61.0)
18000 3/8
1/4 175 250* 250* 250* 250* 250* 250* 250*
5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
24000 3/8
1/4 100 125 175 200 225* 250* 250* 250*
5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
30000 3/8
1/4 30 -- -- -- -- -- -- --
5/16 250* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
36000 3/8 5/16 225* 250* 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
42000 3/8 5/16 175 200 250* 250* 250* 250* 250* 250*
3/8 250* 250* 250* 250* 250* 250* 250* 250*
48000 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
60000 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250*
178
1940
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 4 Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz.(266.16 g). When using other length or diameter liquid lines, charge adjustments are required per the chart above.

Charging Formula:
[(Lineset oz/ft X total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of lineset* using existing 1/4“ liquid line. What charge adjustment is required? Formula:(.27 oz/ft X 15ft) – (9 oz) = (­4.95) oz.

Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula:(.40 oz/ft. X 45ft) – (9 oz.) = 9 oz.

Net result is to add 9 oz of refrigerant to the system
NOTE: Conditions must be favorable for charging by subcooling method. Indoor temperature must be 70°F to 80°F (21°C to 27°C), and outdoor temperature must be 70°F to 100°F (21°C to 38°C). If outside these conditions, adjust charge for long linesets by weigh-in method. * When applicable. Refer to Physical Data Table in this PD and to the Installation Instructions for more information.

Long Line Applications
An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.

For Air Conditioner systems, the chart below shows when an application is considered Long Line.

Note: See Residential Piping and Long Line Guideline for details Table 3 – Refrigerant Charge Adjustments
Liquid Line Size Puron Charge oz/ft (g/m)
3/8 0.60 (17.74)
(Factory charge for lineset = 9 oz / 266.16 g)
5/16 0.40 (11.83)
1/4 0.27 (7.98)
Table 4 – AC with Puron® Refrigerant Long Line Description ft (m) Beyond these lengths, a TXV is required Total Length Outdoor Unit Above or Below Indoor Unit
TXV required beyond 50 ft. (15.2 m) TXV required beyond 20 ft. (6.1 m) Table 5 – AC with Puron® Refrigerant Long Line Description ft (m) (Beyond these lengths, long line accessories are required) Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 + TXV No accessories needed within allowed
lengths
No accessories needed within
allowed lengths 175 (53.3)
5/16 + TXV 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 + TXV 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) 179
1941
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5 VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron® refrigerant:

Table 6 – Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 1-Stage Air Conditioner Applications Unit
Nominal
Size (Btuh)
Maximum
Liquid Line
Diameters
(In. OD)
Vapor Line
Diameters
(In. OD)
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
1-Stage AC with Puron®
26-50
(7.9-15.2)
51-80
(15.5-24.4)
81-100
(24.7-30.5)
101-125
(30.8-38.1)
126-150
(38.4-45.7)
151-175
(46.0-53.3)
176-200
(53.6-61.0)
201-225
(61.3-68.6)
226-250
(68.9-76.2)
18 3/8
1/2 1 2 3 5 6 7 8 9 11
5/8 0 1 1 1 2 2 2 3 3
3/4 0 0 0 0 1 1 1 1 1
24 3/8
5/8 0 1 2 2 3 3 4 5 5
3/4 0 0 1 1 1 1 1 2 2
7/8 0 0 0 0 0 1 1 1 1
30 3/8
5/8 1 2 3 3 4 5 6 7 8
3/4 0 0 1 1 1 2 2 2 3
7/8 0 0 0 0 1 1 1 1 1
36 3/8
5/8 1 2 4 5 6 8 9 10 12
3/4 0 1 1 2 2 3 3 4 4
7/8 0 0 0 1 1 1 1 2 2
42 3/8
3/4 0 1 2 2 3 4 4 5 6
7/8 0 0 1 1 1 2 2 2 3
1 1/8 0 0 0 0 0 0 0 0 0
48 3/8
3/4 0 1 2 3 4 5 5 6 7
7/8 0 0 1 1 2 2 2 3 3
1 1/8 0 0 0 0 0 0 0 1 1
60 3/8
3/4 1 2 4 5 6 7 9 10 11
7/8 0 1 2 2 3 4 4 5 5
1 1/8 0 0 0 1 1 1 1 1 1
Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 180
1942
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 6 X = Accessory

ACCESSORIES
KIT NUMBER KIT NAME 18 24 30 36 42 48 60
KSAFT0101AAA FRZ THERM KIT X X X X X X X
KAATD0101TDR TIME DELAY KIT (90 second TDR) X X X X X X X KAATD0201TDR TIME DELAY KIT (30 second TDR) X X X X X X X KSALA0301410 LOW AMBIENT COOLING KIT X X X X X X X
KSALA1001AAA MOTORMASTER KIT X X X X X X X
KSAHS2501AAA HARD START KIT X X X X X X X
KSACY0101AAA CYCLE PROTR KIT X X X X X X X
KSASF0201AAA SPRT FEET KIT X X X X X X X
KAALS0201LLS* SOL VALVE KIT X X X X X X X
KAAWS0101AAA WINTER ST KIT X X X X X X X
KAALP0401PUR LOW PRESSURE SW KIT X X X X X X X
KAAHI0501PUR HIGH PRESSURE SW KIT X X X X X X X
KAACH1701AAA CRKC HTR KIT X X X X
KAACH1601AAA CRKC HTR KIT X X X
KSATX0201PUR TXV KIT (For use with copper coils) X X X
KSATX0301PUR TXV KIT (For use with copper coils) X X
KSATX0401PUR TXV KIT (For use with copper coils) X X
KSBTX0201PUR TXV KIT (For use with aluminum coils) X X X KSBTX0301PUR TXV KIT (For use with aluminum coils) X X
KSBTX0401PUR TXV KIT (For use with aluminum coils) X X
KSASH2301COP SOUND BLKT KIT X X X X
KSASH2401COP SOUND BLKT KIT X X X
181
1943
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 7 ACCESSORY USAGE GUIDELINE
Accessory Description and Usage (Listed Alphabetically)

1. Ball-Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.

Usage Guideline:

Required on all units when MotorMasterr is used.

2. Compressor Start Assist - Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.

Usage Guideline:

Required for single-phase scroll compressors in the following applications:

Long line
Low ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.

3. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.

Usage Guideline:

Required in low ambient cooling applications.

Required in long line applications.

Suggested in all commercial applications.

4. Cycle Protector
The cycle protector is designed to prevent compressor short cycling.

This control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.

5. Evaporator Freeze Thermostat
An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.

Usage Guideline:

Required when low ambient kit has been added.

6. Low-Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0_F (-18_C) when properly installed and also using wind baffles. Instructions provided in accessory kit.

Usage Guideline:

A Low-Ambient Pressure Switch or MotorMasterr Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

7. MotorMasterr Low-Ambient Controller
A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to –10°F/–23.3°C), it maintains condensing temperature at 100_F ±10_F (37.8_C ±5.5_C).

Usage Guideline:

A MotorMasterr Low Ambient Controller or Low-Ambient
Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).

Suggested for all commercial applications.

8. Outdoor Air Temperature Sensor
This device enables the thermostat to display the outdoor temperature.

This device is also required to enable special thermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for use with compatible Carrier thermostats.

9. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the sound level of the compressor.

Usage Guideline:

Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses less than 10 ft (3 m) apart.

ACCESSORY

REQUIRED FOR

LOW-AMBIENT COOLING

APPLICATIONS
(Below 55_F/12.8_C)

REQUIRED FOR LONG
LINE APPLICATIONS*
*.For tubing set lengths between 80 and 200 ft. (24 and 61 m) horizontal or 35 ft. (10.7 m) vertical differential (total equivalent length), refer to the Residential Split-System Long Line Application Guideline.

REQUIRED FOR

SEA COAST

APPLICATIONS
(Within 2 miles/3.22 km)
Ball Bearing Fan Motor Standard Standard Standard
Compressor Start Assist Capacitor and Relay Yes Yes No
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Hard Shut-Off TXV Yes Yes No
Liquid Line Solenoid Valve No See Long Line Guideline No MotorMaster® Control or
Low-ambient Pressure Switch Yes No No
Support Feet Recommended No Recommended
Winter Start Control Yes†
†.Required if Low Pressure Switch is factory or field installed.

No No
182
1944
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 8 Accessory Description and Usage (Listed Alphabetically) Continued

10. Support Feet
Four or five stick-on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.

Usage Guideline:

Suggested in the following applications:

Coastal installations.

Windy areas or where debris is normally circulating.

Rooftop installations.

For improved sound ratings.

11. Thermostatic Expansion Valve (TXV)
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.

Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available.

Usage Guideline:

Required to achieve AHRI ratings in certain equipment
combinations. Refer to combination ratings.

Hard shut off TXV or LLS required in air conditioner long line applications.

Required for use on all zoning systems.

12. Time-Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.

NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.

Usage Guideline:

For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Directory of Certified Product Performance (AHRI Directory).

When a Time-Delay Relay (TDR) is called for in the AHRI Directory, use a 30 second TDR for MicroChannel Indoor units and use a 90 second TDR for Round Tube Plate Fin Indoor units.

13. Winter Start Control
This control is designed to alleviate nuisance opening of the low-pressure switch by bypassing it for the first 3 minutes of operation. 183
1945
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 9 AHRI RATINGS
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Ratings Database here: www.MyCarrierRatings.com FLA- Full Load Amps
LRA - Locked Rotor Amps
MCA- Minimum Circuit Amps
RLA- Rated Load Amps
NOTE:Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit.

All motors/compressors contain internal overload protection.

Complies with requirements of ASHRAE Standards 90.1
NOTE: Tested in compliance with AHRI 270 but not listed with AHRI.

NOTE: Tested in compliance with AHRI 270 but not listed with AHRI.

Electrical Data
UNIT SIZE V/PH OPER VOLTS*
*.Permissible limits of the voltage range at which the unit will operate satisfactorily COMPR FAN MCA MAX FUSE† or CKT BRK
AMPS
†.Time-Delay fuse.

MAX MIN LRA RLA FLA
18 208-230/1 253 197

48.0 8.00 0.40 10.4 15
24 59.5 11.70 0.50 15.1 25
30 64.3 11.80 0.75 15.6 25
36 80.1 12.20 1.05 16.4 25
42 110.2 17.70 1.40 23.5 40
48 124.0 18.50 1.40 24.5 40
60 150.0 25.60 1.52 33.5 50
Sound Power Level without sound shield

UNIT SIZE STANDARD
RATING (dBA)
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) (dB) 125 250 500 1000 2000 4000 8000
18 75 68.9 65.3 65.6 71.4 68.4 63.8 61.2
24 74 66.9 72.6 70.0 70.7 66.6 62.7 59.2
30 73 69.5 68.9 68.9 68.5 62.8 60.0 57.4
36 75 70.8 73.6 71.5 69.5 66.1 63.6 58.1
42 73 73.9 72.6 70.3 68.2 64.3 61.2 57.3
48 76 72.3 74.1 71.2 70.6 63.8 61.6 55.9
60 76 70.0 75.0 71.9 73.7 66.0 61.7 56.3
Sound Power Level with Accessory sound shield

UNIT SIZE STANDARD
RATING (dBA)
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) (dB) 125 250 500 1000 2000 4000 8000
18 75 66.4 67.0 66.1 71.5 66.6 62.5 61.1
24 74 68.4 72.2 70.4 70.2 66.0 62.3 58.5
30 72 69.3 69.7 68.8 68.0 62.4 59.5 55.7
36 75 71.0 73.7 71.2 69.0 65.4 63.0 57.7
42 73 75.3 71.7 70.0 68.1 63.9 60.2 55.3
48 74 73.3 74.2 71.6 69.9 63.8 60.4 54.7
60 75 70.2 73.9 71.8 72.4 64.2 60.4 54.6
Charging Subcooling (TXV-Type Expansion Device)
UNIT SIZE REQUIRED SUBCOOLING (F) Indoor
18 14
TXV
24 10
30 10
36 10
42 11
48 12
60 12
184
1946
24SCA4: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 10 DIMENSIONS
185
1947
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
186
1948
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
APPENDIX 9.2:

CADNAAOPERATIONAL NOISE CALCULATIONS
187
1949
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
188
1950
14638 - Best Buy - Orange
CadnaA Noise Prediction Model: 16438-02_Operation.cna
Date: 21.10.25
Analyst: B. Maddux
Calculation Configuration
Configuration
Parameter Value
General
Max. Error (dB) 0.00
Max. Search Radius (ft) 6561.70
Min. Dist Src to Rcvr 0.00
Partition
Raster Factor 0.50
Max. Length of Section (ft) 3280.80
Min. Length of Section (ft) 3.30
Min. Length of Section (%) 0.00
Proj. Line Sources On
Proj. Area Sources On
Ref. Time
Daytime Penalty (dB) 0.00
Recr. Time Penalty (dB) 5.00
Night-time Penalty (dB) 10.00
DTM
Standard Height (m) 0.00
Model of Terrain Triangulation
Reflection
max. Order of Reflection 2
Search Radius Src 328.08
Search Radius Rcvr 328.08
Max. Distance Source - Rcvr 3280.84 3280.84
Min. Distance Rvcr - Reflector 3.28 3.28
Min. Distance Source - Reflector 0.33
Industrial (ISO 9613 (1996))
Lateral Diffraction some Obj
Obst. within Area Src do not shield On
Screening Incl. Ground Att. over Barrier
Dz with limit (20/25)
Barrier Coefficients C1,2,3 3.0 20.0 0.0
Temperature (°F) 50
rel. Humidity (%) 70
Ground Absorption G 0.50
Wind Speed for Dir. (mph) 6.7
Roads (TNM)
Railways (FTA/FRA)
Aircraft (???)
Strictly acc. to AzB
Receiver Noise Levels
Name M. ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) (ft) (ft) (ft) (ft) R1 R1 41.2 38.5 45.2 0.0 0.0 0.0 x Total 5.00 r 6080468.98 2248762.73 5.00 R2 R2 47.6 44.9 51.6 0.0 0.0 0.0 x Total 5.00 r 6080706.13 2248376.27 5.00 R3 R3 43.4 40.6 47.4 0.0 0.0 0.0 x Total 5.00 r 6080399.12 2248347.66 5.00 R4 R4 33.6 30.9 37.6 0.0 0.0 0.0 x Total 5.00 r 6081006.30 2248678.53 5.00 Point Source(s)
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) AC01 AC01 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080244.08 2248504.94 5.00 AC02 AC02 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080243.73 2248500.25 5.00 AC03 AC03 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080243.56 2248447.13 5.00 AC04 AC04 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080243.38 2248442.09 5.00 AC05 AC05 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080243.21 2248388.62 5.00 AC06 AC06 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080346.73 2248386.15 5.00 AC07 AC07 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080392.95 2248385.71 5.00 AC08 AC08 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080397.94 2248385.71 5.00 AC09 AC09 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080451.11 2248385.71 5.00 AC10 AC10 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080455.67 2248385.71 5.00 AC11 AC11 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080507.97 2248385.71 5.00 AC12 AC12 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080513.39 2248385.50 5.00 AC13 AC13 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080565.69 2248385.28 5.00 AC14 AC14 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080570.90 2248385.28 5.00 AC15 AC15 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080623.85 2248385.28 5.00 AC16 AC16 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080628.84 2248385.06 5.00 Urban Crossroads, Inc.
189
1951
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) AC17 AC17 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080681.36 2248385.28 5.00 AC18 AC18 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080686.14 2248385.06 5.00 AC19 AC19 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080738.87 2248384.85 5.00 AC20 AC20 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080744.08 2248384.41 5.00 AC21 AC21 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080705.88 2248702.77 5.00 AC22 AC22 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080700.89 2248702.55 5.00 AC23 AC23 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080648.16 2248703.20 5.00 AC24 AC24 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080642.95 2248702.99 5.00 AC25 AC25 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080590.65 2248703.20 5.00 AC26 AC26 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080585.01 2248702.77 5.00 AC27 AC27 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080532.92 2248703.20 5.00 AC28 AC28 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080527.50 2248702.99 5.00 AC29 AC29 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080475.20 2248703.20 5.00 AC30 AC30 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080469.99 2248703.42 5.00 AC31 AC31 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080417.47 2248703.64 5.00 AC32 AC32 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080412.05 2248703.64 5.00 AC33 AC33 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080359.96 2248703.64 5.00 AC34 AC34 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080354.10 2248704.07 5.00 AC35 AC35 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080301.37 2248704.29 5.00 AC36 AC36 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080359.25 2248617.17 37.00 AC37 AC37 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080376.52 2248619.30 37.00 AC38 AC38 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080415.27 2248616.34 37.00 AC39 AC39 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080451.98 2248608.98 37.00 AC40 AC40 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080450.87 2248591.97 37.00 AC41 AC41 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080450.24 2248547.72 37.00 AC42 AC42 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080450.71 2248531.99 37.00 AC43 AC43 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080525.94 2248608.30 37.00 AC44 AC44 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080526.85 2248586.83 37.00 AC45 AC45 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080526.20 2248547.10 37.00 AC46 AC46 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080525.79 2248530.25 37.00 AC47 AC47 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080583.52 2248606.87 37.00 AC48 AC48 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080583.04 2248589.61 37.00 AC49 AC49 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080583.61 2248547.76 37.00 AC50 AC50 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080583.46 2248530.16 37.00 AC51 AC51 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080656.57 2248607.36 37.00 AC52 AC52 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080657.89 2248589.84 37.00 AC53 AC53 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080658.23 2248548.13 37.00 AC54 AC54 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080658.98 2248530.04 37.00 AC55 AC55 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080720.49 2248604.26 37.00 AC56 AC56 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080722.38 2248565.12 37.00 AC57 AC57 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080722.38 2248553.91 37.00 AC58 AC58 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080721.69 2248510.98 37.00 AC59 AC59 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080366.91 2248480.33 5.00 AC60 AC60 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080373.20 2248479.90 5.00 AC61 AC61 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080422.68 2248480.55 5.00 AC62 AC62 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080430.49 2248480.55 5.00 AC63 AC63 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080480.84 2248479.68 5.00 AC64 AC64 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080487.79 2248479.68 5.00 AC65 AC65 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080537.70 2248480.11 5.00 AC66 AC66 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080545.29 2248480.11 5.00 AC67 AC67 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080595.64 2248479.25 5.00 AC68 AC68 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080602.59 2248479.03 5.00 AC69 AC69 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080652.93 2248478.16 5.00 AC70 AC70 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080659.66 2248478.38 5.00 AC71 AC71 76.0 76.0 76.0 Lw 76 675.00 0.00 270.00 5.00 g 6080710.66 2248474.04 5.00 Line Source(s)
Name M. ID Result. PWL Result. PWL' Lw / Li Operating Time Moving Pt. Src Height Day Evening Night Day Evening Night Type Value norm. Day Special Night Number Speed (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) Day Evening Night (mph) (ft) Name ID Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
Area Source(s)
Name M. ID Result. PWL Result. PWL'' Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm. Day Special Night (ft) (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) PARK1 PARK1 74.0 74.0 74.0 54.1 54.1 54.1 Lw 74 900.00 0.00 270.00 5 r PARK2 PARK2 76.0 76.0 76.0 54.9 54.9 54.9 Lw 76 900.00 0.00 270.00 5 r PARK3 PARK3 77.0 77.0 77.0 54.4 54.4 54.4 Lw 77 900.00 0.00 270.00 5 r PARK4 PARK4 71.0 71.0 71.0 54.2 54.2 54.2 Lw 71 900.00 0.00 270.00 5 r PARK5 PARK5 73.0 73.0 73.0 54.9 54.9 54.9 Lw 73 900.00 0.00 270.00 5 r Urban Crossroads, Inc.
190
1952
Name ID Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
PARK1 PARK1 5.00 r 6080315.35 2248612.43 5.00 0.00
6080333.45 2248611.91 5.00 0.00
6080333.19 2248555.66 5.00 0.00
6080313.92 2248556.18 5.00 0.00
PARK2 PARK2 5.00 r 6080314.70 2248547.20 5.00 0.00
6080335.93 2248546.94 5.00 0.00
6080335.41 2248482.61 5.00 0.00
6080313.79 2248482.48 5.00 0.00
PARK3 PARK3 5.00 r 6080716.53 2248505.40 5.00 0.00
6080771.47 2248503.58 5.00 0.00
6080772.00 2248442.77 5.00 0.00
6080762.62 2248442.77 5.00 0.00
6080762.23 2248473.76 5.00 0.00
6080716.66 2248475.32 5.00 0.00
PARK4 PARK4 5.00 r 6080687.23 2248634.31 5.00 0.00
6080716.53 2248635.22 5.00 0.00
6080716.14 2248616.73 5.00 0.00
6080687.23 2248617.12 5.00 0.00
PARK5 PARK5 5.00 r 6080310.88 2248419.64 5.00 0.00
6080329.24 2248419.12 5.00 0.00
6080328.85 2248381.62 5.00 0.00
6080310.62 2248381.36 5.00 0.00
Barrier(s)
Name Sel. M. ID Absorption Z-Ext. Cantilever Height Coordinates left right horz. vert. Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft) (ft) (ft) (ft)
BAR1 BAR1 0.99 0.99 6.00 r 6080294.67 2248708.32 6.00 0.00 6080768.94 2248713.25 6.00 0.00
6080770.62 2248521.02 6.00 0.00
6080778.82 2248521.21 6.00 0.00
6080779.94 2248381.75 6.00 0.00
6080229.37 2248378.02 6.00 0.00
6080229.00 2248531.65 6.00 0.00
Building(s)
Name Sel. M. ID RB Residents Absorption Height Coordinates Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
BLDG01 BLDG01 x 0 32.00 r 6080678.06 2248675.67 32.00 0.00 6080678.32 2248700.84 32.00 0.00
6080728.50 2248700.67 32.00 0.00
6080728.41 2248675.14 32.00 0.00
6080724.50 2248675.32 32.00 0.00
6080724.33 2248664.29 32.00 0.00
6080682.14 2248664.55 32.00 0.00
6080681.97 2248675.49 32.00 0.00
BLDG02 BLDG02 x 0 32.00 r 6080670.51 2248675.32 32.00 0.00 6080666.69 2248675.58 32.00 0.00
6080666.86 2248664.29 32.00 0.00
6080624.24 2248664.38 32.00 0.00
6080624.24 2248675.93 32.00 0.00
6080620.25 2248675.84 32.00 0.00
6080620.51 2248701.19 32.00 0.00
6080670.94 2248701.10 32.00 0.00
BLDG03 BLDG03 x 0 32.00 r 6080562.79 2248701.62 32.00 0.00 6080612.96 2248701.19 32.00 0.00
6080613.13 2248675.84 32.00 0.00
6080608.97 2248675.67 32.00 0.00
6080608.88 2248664.81 32.00 0.00
6080566.52 2248664.90 32.00 0.00
6080566.60 2248676.36 32.00 0.00
6080562.52 2248676.01 32.00 0.00
BLDG04 BLDG04 x 0 32.00 r 6080555.23 2248701.62 32.00 0.00 6080555.32 2248675.93 32.00 0.00
6080550.98 2248675.84 32.00 0.00
6080551.07 2248664.90 32.00 0.00
6080508.71 2248665.08 32.00 0.00
6080508.71 2248676.36 32.00 0.00
6080504.97 2248676.45 32.00 0.00
6080505.32 2248701.71 32.00 0.00
BLDG05 BLDG05 x 0 32.00 r 6080497.68 2248701.79 32.00 0.00 6080497.68 2248676.10 32.00 0.00
6080493.60 2248675.93 32.00 0.00
6080493.69 2248665.16 32.00 0.00
Urban Crossroads, Inc.
191
1953
Name Sel. M. ID RB Residents Absorption Height Coordinates Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
6080450.98 2248665.16 32.00 0.00
6080451.24 2248676.97 32.00 0.00
6080447.16 2248676.88 32.00 0.00
6080447.42 2248702.05 32.00 0.00
BLDG06 BLDG06 x 0 32.00 r 6080389.52 2248702.14 32.00 0.00 6080439.52 2248702.05 32.00 0.00
6080439.78 2248676.71 32.00 0.00
6080435.79 2248676.45 32.00 0.00
6080435.70 2248665.42 32.00 0.00
6080393.60 2248665.51 32.00 0.00
6080393.43 2248676.97 32.00 0.00
6080389.35 2248676.97 32.00 0.00
BLDG07 BLDG07 x 0 32.00 r 6080331.97 2248702.49 32.00 0.00 6080381.97 2248702.31 32.00 0.00
6080382.32 2248676.79 32.00 0.00
6080378.15 2248676.62 32.00 0.00
6080378.24 2248666.20 32.00 0.00
6080335.88 2248666.03 32.00 0.00
6080335.79 2248676.97 32.00 0.00
6080331.71 2248677.05 32.00 0.00
BLDG08 BLDG08 x 0 32.00 r 6080324.59 2248702.40 32.00 0.00 6080324.33 2248676.97 32.00 0.00
6080320.51 2248677.14 32.00 0.00
6080320.42 2248666.03 32.00 0.00
6080299.07 2248666.12 32.00 0.00
6080299.42 2248702.31 32.00 0.00
BLDG09 BLDG09 x 0 32.00 r 6080697.55 2248611.28 32.00 0.00 6080734.23 2248610.41 32.00 0.00
6080734.12 2248563.64 32.00 0.00
6080695.71 2248563.75 32.00 0.00
6080696.03 2248578.94 32.00 0.00
6080697.55 2248578.94 32.00 0.00
6080697.55 2248587.84 32.00 0.00
6080696.36 2248587.51 32.00 0.00
6080696.03 2248601.19 32.00 0.00
6080697.66 2248601.62 32.00 0.00
BLDG10 BLDG10 x 0 32.00 r 6080695.81 2248556.16 32.00 0.00 6080734.12 2248556.05 32.00 0.00
6080734.12 2248509.28 32.00 0.00
6080717.95 2248509.50 32.00 0.00
6080718.06 2248507.98 32.00 0.00
6080697.01 2248508.63 32.00 0.00
6080696.90 2248518.61 32.00 0.00
6080695.71 2248518.61 32.00 0.00
6080695.81 2248532.18 32.00 0.00
6080697.44 2248532.50 32.00 0.00
6080697.01 2248540.86 32.00 0.00
6080695.60 2248541.07 32.00 0.00
BLDG11 BLDG11 x 0 32.00 r 6080720.23 2248423.02 32.00 0.00 6080763.20 2248423.02 32.00 0.00
6080762.87 2248411.30 32.00 0.00
6080766.78 2248411.52 32.00 0.00
6080766.78 2248386.02 32.00 0.00
6080716.43 2248386.34 32.00 0.00
6080716.54 2248411.19 32.00 0.00
6080720.45 2248411.52 32.00 0.00
BLDG12 BLDG12 x 0 32.00 r 6080662.94 2248423.13 32.00 0.00 6080705.04 2248423.13 32.00 0.00
6080705.25 2248411.84 32.00 0.00
6080708.94 2248411.84 32.00 0.00
6080708.94 2248386.13 32.00 0.00
6080658.60 2248386.78 32.00 0.00
6080658.71 2248411.73 32.00 0.00
6080662.61 2248411.84 32.00 0.00
BLDG13 BLDG13 x 0 32.00 r 6080604.99 2248423.56 32.00 0.00 6080647.53 2248423.34 32.00 0.00
6080647.42 2248412.17 32.00 0.00
6080651.22 2248412.17 32.00 0.00
6080651.22 2248386.56 32.00 0.00
6080600.98 2248386.78 32.00 0.00
6080601.31 2248412.17 32.00 0.00
6080605.21 2248412.17 32.00 0.00
BLDG14 BLDG14 x 0 32.00 r 6080547.59 2248423.67 32.00 0.00 6080589.59 2248423.67 32.00 0.00
6080589.91 2248412.38 32.00 0.00
6080593.93 2248412.28 32.00 0.00
6080593.60 2248386.89 32.00 0.00
Urban Crossroads, Inc.
192
1954
Name Sel. M. ID RB Residents Absorption Height Coordinates Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
6080543.36 2248386.89 32.00 0.00
6080543.36 2248411.95 32.00 0.00
6080547.49 2248412.49 32.00 0.00
BLDG15 BLDG15 x 0 32.00 r 6080489.76 2248423.78 32.00 0.00 6080532.08 2248423.89 32.00 0.00
6080532.08 2248412.82 32.00 0.00
6080535.77 2248412.71 32.00 0.00
6080535.98 2248387.32 32.00 0.00
6080485.85 2248387.43 32.00 0.00
6080485.75 2248412.71 32.00 0.00
6080489.65 2248412.71 32.00 0.00
BLDG16 BLDG16 x 0 32.00 r 6080432.03 2248424.32 32.00 0.00 6080474.35 2248423.99 32.00 0.00
6080474.35 2248413.04 32.00 0.00
6080478.48 2248413.04 32.00 0.00
6080478.37 2248387.32 32.00 0.00
6080428.02 2248387.75 32.00 0.00
6080428.24 2248412.71 32.00 0.00
6080431.93 2248412.82 32.00 0.00
BLDG17 BLDG17 x 0 32.00 r 6080374.42 2248424.10 32.00 0.00 6080416.30 2248424.32 32.00 0.00
6080416.73 2248413.36 32.00 0.00
6080420.75 2248413.14 32.00 0.00
6080420.53 2248387.43 32.00 0.00
6080370.29 2248387.86 32.00 0.00
6080370.29 2248413.04 32.00 0.00
6080374.31 2248413.14 32.00 0.00
BLDG18 BLDG18 x 0 32.00 r 6080340.13 2248425.62 32.00 0.00 6080362.92 2248425.41 32.00 0.00
6080363.24 2248387.10 32.00 0.00
6080349.03 2248387.10 32.00 0.00
6080348.81 2248388.51 32.00 0.00
6080339.26 2248388.95 32.00 0.00
6080339.48 2248398.06 32.00 0.00
6080338.39 2248398.28 32.00 0.00
6080338.50 2248410.00 32.00 0.00
6080339.91 2248409.78 32.00 0.00
BLDG19 BLDG19 x 0 32.00 r 6080244.97 2248411.84 32.00 0.00 6080270.03 2248411.84 32.00 0.00
6080270.36 2248407.72 32.00 0.00
6080281.64 2248407.39 32.00 0.00
6080281.54 2248386.78 32.00 0.00
6080245.29 2248386.78 32.00 0.00
BLDG20 BLDG20 x 0 32.00 r 6080245.40 2248469.68 32.00 0.00 6080270.14 2248469.46 32.00 0.00
6080270.90 2248465.23 32.00 0.00
6080281.43 2248465.23 32.00 0.00
6080281.75 2248423.67 32.00 0.00
6080270.90 2248423.13 32.00 0.00
6080271.01 2248419.22 32.00 0.00
6080244.97 2248419.44 32.00 0.00
BLDG21 BLDG21 x 0 32.00 r 6080245.84 2248527.51 32.00 0.00 6080271.12 2248527.51 32.00 0.00
6080271.34 2248523.60 32.00 0.00
6080282.08 2248523.17 32.00 0.00
6080282.19 2248480.85 32.00 0.00
6080271.12 2248481.07 32.00 0.00
6080271.01 2248476.84 32.00 0.00
6080245.62 2248477.05 32.00 0.00
BLDG22 BLDG22 x 0 32.00 r 6080342.08 2248493.44 32.00 0.00 6080351.41 2248493.33 32.00 0.00
6080351.52 2248494.85 32.00 0.00
6080365.30 2248494.85 32.00 0.00
6080365.41 2248456.55 32.00 0.00
6080342.19 2248456.44 32.00 0.00
6080342.52 2248472.61 32.00 0.00
6080340.89 2248472.82 32.00 0.00
6080341.11 2248484.11 32.00 0.00
6080341.97 2248484.00 32.00 0.00
BLDG23 BLDG23 x 0 32.00 r 6080374.42 2248494.52 32.00 0.00 6080389.50 2248494.63 32.00 0.00
6080389.50 2248493.11 32.00 0.00
6080421.62 2248493.33 32.00 0.00
6080421.18 2248455.68 32.00 0.00
6080374.20 2248456.00 32.00 0.00
BLDG24 BLDG24 x 0 32.00 r 6080431.82 2248494.52 32.00 0.00 6080446.68 2248494.42 32.00 0.00
Urban Crossroads, Inc.
193
1955
Name Sel. M. ID RB Residents Absorption Height Coordinates Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
6080446.90 2248492.68 32.00 0.00
6080479.23 2248493.00 32.00 0.00
6080478.80 2248455.79 32.00 0.00
6080431.49 2248456.11 32.00 0.00
BLDG25 BLDG25 x 0 32.00 r 6080489.43 2248493.76 32.00 0.00 6080504.30 2248493.98 32.00 0.00
6080504.19 2248492.57 32.00 0.00
6080536.42 2248492.79 32.00 0.00
6080536.31 2248455.57 32.00 0.00
6080489.22 2248455.79 32.00 0.00
BLDG26 BLDG26 x 0 32.00 r 6080546.83 2248493.76 32.00 0.00 6080561.70 2248493.66 32.00 0.00
6080561.59 2248492.57 32.00 0.00
6080593.60 2248492.46 32.00 0.00
6080593.82 2248455.14 32.00 0.00
6080546.62 2248455.79 32.00 0.00
BLDG27 BLDG27 x 0 32.00 r 6080604.34 2248493.66 32.00 0.00 6080619.32 2248493.66 32.00 0.00
6080619.32 2248492.03 32.00 0.00
6080651.33 2248492.25 32.00 0.00
6080651.11 2248455.14 32.00 0.00
6080603.91 2248455.24 32.00 0.00
BLDG28 BLDG28 x 0 32.00 r 6080661.85 2248493.33 32.00 0.00 6080676.72 2248493.44 32.00 0.00
6080676.72 2248491.92 32.00 0.00
6080685.51 2248491.59 32.00 0.00
6080685.29 2248493.11 32.00 0.00
6080698.96 2248493.11 32.00 0.00
6080699.18 2248491.92 32.00 0.00
6080708.94 2248491.59 32.00 0.00
6080709.49 2248470.54 32.00 0.00
6080708.18 2248470.44 32.00 0.00
6080707.97 2248454.81 32.00 0.00
6080661.53 2248455.14 32.00 0.00
BLDG29 BLDG29 x 0 32.00 r 6080434.01 2248533.93 32.00 0.00 6080471.38 2248533.80 32.00 0.00
6080472.42 2248510.37 32.00 0.00
6080456.40 2248510.37 32.00 0.00
6080456.40 2248509.06 32.00 0.00
6080435.18 2248510.37 32.00 0.00
6080435.31 2248519.61 32.00 0.00
6080434.14 2248519.61 32.00 0.00
BLDG30 BLDG30 x 0 32.00 r 6080505.10 2248532.76 32.00 0.00 6080543.64 2248533.02 32.00 0.00
6080543.38 2248519.35 32.00 0.00
6080541.95 2248519.22 32.00 0.00
6080541.82 2248509.32 32.00 0.00
6080520.86 2248509.06 32.00 0.00
6080520.47 2248510.89 32.00 0.00
6080505.23 2248510.37 32.00 0.00
BLDG31 BLDG31 x 0 32.00 r 6080565.65 2248533.02 32.00 0.00 6080603.41 2248532.89 32.00 0.00
6080603.67 2248509.98 32.00 0.00
6080587.92 2248509.98 32.00 0.00
6080587.65 2248508.41 32.00 0.00
6080566.95 2248509.19 32.00 0.00
6080566.95 2248519.09 32.00 0.00
6080565.52 2248519.09 32.00 0.00
BLDG32 BLDG32 x 0 32.00 r 6080636.87 2248532.24 32.00 0.00 6080674.50 2248532.76 32.00 0.00
6080674.89 2248518.57 32.00 0.00
6080673.07 2248518.70 32.00 0.00
6080673.33 2248508.93 32.00 0.00
6080652.37 2248508.28 32.00 0.00
6080652.24 2248509.71 32.00 0.00
6080636.74 2248509.85 32.00 0.00
BLDG33 BLDG33 x 0 32.00 r 6080636.87 2248592.79 32.00 0.00 6080675.15 2248592.53 32.00 0.00
6080675.42 2248577.42 32.00 0.00
6080673.72 2248577.81 32.00 0.00
6080674.11 2248545.91 32.00 0.00
6080636.74 2248545.78 32.00 0.00
BLDG34 BLDG34 x 0 32.00 r 6080566.95 2248593.05 32.00 0.00 6080603.54 2248592.79 32.00 0.00
6080603.67 2248545.39 32.00 0.00
6080566.04 2248546.17 32.00 0.00
6080565.78 2248561.28 32.00 0.00
Urban Crossroads, Inc.
194
1956
Name Sel. M. ID RB Residents Absorption Height Coordinates Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
6080567.34 2248561.15 32.00 0.00
BLDG35 BLDG35 x 0 32.00 r 6080505.75 2248593.44 32.00 0.00 6080543.12 2248593.18 32.00 0.00
6080543.77 2248577.94 32.00 0.00
6080542.08 2248578.20 32.00 0.00
6080542.86 2248545.78 32.00 0.00
6080505.36 2248546.04 32.00 0.00
BLDG36 BLDG36 x 0 32.00 r 6080435.31 2248593.44 32.00 0.00 6080472.55 2248593.31 32.00 0.00
6080472.55 2248546.30 32.00 0.00
6080434.27 2248546.43 32.00 0.00
6080434.40 2248561.41 32.00 0.00
6080435.57 2248561.28 32.00 0.00
BLDG37 BLDG37 x 0 32.00 r 6080341.30 2248633.54 32.00 0.00 6080364.35 2248633.54 32.00 0.00
6080363.96 2248595.65 32.00 0.00
6080349.76 2248595.39 32.00 0.00
6080349.63 2248596.56 32.00 0.00
6080340.52 2248597.08 32.00 0.00
6080340.00 2248617.79 32.00 0.00
6080341.17 2248618.05 32.00 0.00
BLDG38 BLDG38 x 0 32.00 r 6080372.68 2248633.41 32.00 0.00 6080419.30 2248633.67 32.00 0.00
6080419.30 2248595.39 32.00 0.00
6080404.58 2248595.00 32.00 0.00
6080404.58 2248597.08 32.00 0.00
6080372.42 2248596.69 32.00 0.00
BLDG39 BLDG39 x 0 32.00 r 6080435.96 2248629.77 32.00 0.00 6080451.46 2248630.16 32.00 0.00
6080451.46 2248630.81 32.00 0.00
6080456.93 2248630.68 32.00 0.00
6080456.93 2248629.51 32.00 0.00
6080472.68 2248629.12 32.00 0.00
6080472.42 2248605.81 32.00 0.00
6080434.27 2248606.20 32.00 0.00
6080434.66 2248620.65 32.00 0.00
6080435.83 2248620.91 32.00 0.00
BLDG40 BLDG40 x 0 32.00 r 6080505.41 2248629.12 32.00 0.00 6080521.30 2248629.12 32.00 0.00
6080521.30 2248630.16 32.00 0.00
6080541.87 2248629.77 32.00 0.00
6080541.74 2248620.00 32.00 0.00
6080543.31 2248620.00 32.00 0.00
6080543.17 2248605.94 32.00 0.00
6080505.28 2248606.20 32.00 0.00
BLDG41 BLDG41 x 0 32.00 r 6080567.60 2248629.25 32.00 0.00 6080576.98 2248629.25 32.00 0.00
6080576.98 2248630.03 32.00 0.00
6080588.44 2248630.03 32.00 0.00
6080588.44 2248628.60 32.00 0.00
6080603.93 2248628.46 32.00 0.00
6080604.32 2248605.81 32.00 0.00
6080566.17 2248605.94 32.00 0.00
6080566.17 2248619.22 32.00 0.00
6080567.60 2248619.61 32.00 0.00
BLDG42 BLDG42 x 0 32.00 r 6080637.26 2248628.86 32.00 0.00 6080653.15 2248628.46 32.00 0.00
6080653.15 2248629.51 32.00 0.00
6080663.96 2248629.77 32.00 0.00
6080664.48 2248628.99 32.00 0.00
6080673.46 2248628.73 32.00 0.00
6080673.85 2248619.35 32.00 0.00
6080675.15 2248619.22 32.00 0.00
6080675.29 2248605.42 32.00 0.00
6080637.00 2248605.29 32.00 0.00
Ground Absorption(s)
Name Sel. M. ID G Coordinates
x y
(ft) (ft)
Contour(s)
Name Sel. M. ID OnlyPts Height Coordinates
Begin End x y z
(ft) (ft) (ft) (ft) (ft)
Urban Crossroads, Inc.
195
1957
Vertical Area Source(s)
Name ID Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
Rail
Name Sel. M. ID Lw' Train Class Correct. Vmax
Day Night Track
(dBA) (dBA) (dB) (km(mph)
Sound Level Spectra
Name ID Type Oktave Spectrum (dB) Source
Weight. 31.5 63 125 250 500 1000 2000 4000 8000 A lin
Roads
Name Sel. M. ID Lme Count Data exact Count Data Speed Limit SCS Surface Gradient Mult. Reflection Day Evening Night DTV Str.class. M p (%) Auto Truck Dist. Dstro Type Drefl Hbuild Dist. (dBA) (dBA) (dBA) Day Evening Night Day Evening Night (mph) (mph) (dB) (%) (dB) (ft) (ft) RoadsGeo
Name Height Coordinates Dist LSlope
Begin End x y z Ground (ft) (%)
(ft) (ft) (ft) (ft) (ft) (ft)
Urban Crossroads, Inc.
196
1958
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
197
1959
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
APPENDIX 10.1:

CONSTRUCTION NOISE CALCULATIONS
198
1960
ͭͲͰͯʹ‐ͬͰ NA redlines North Tustin Avenue Project
This page was intentionally left blank.
199
1961
14638 - Best Buy - Orange
CadnaA Noise Prediction Model: 16438-02_Construction.cna Date: 14.10.25
Analyst: B. Maddux
Calculation Configuration
Configuration
Parameter Value
General
Max. Error (dB) 0.00
Max. Search Radius (ft) 6561.70
Min. Dist Src to Rcvr 0.00
Partition
Raster Factor 0.50
Max. Length of Section (ft) 3280.80
Min. Length of Section (ft) 3.30
Min. Length of Section (%) 0.00
Proj. Line Sources On
Proj. Area Sources On
Ref. Time
Daytime Penalty (dB) 0.00
Recr. Time Penalty (dB) 5.00
Night-time Penalty (dB) 10.00
DTM
Standard Height (m) 0.00
Model of Terrain Triangulation
Reflection
max. Order of Reflection 2
Search Radius Src 328.08
Search Radius Rcvr 328.08
Max. Distance Source - Rcvr 3280.84 3280.84
Min. Distance Rvcr - Reflector 3.28 3.28
Min. Distance Source - Reflector 0.33
Industrial (ISO 9613 (1996))
Lateral Diffraction some Obj
Obst. within Area Src do not shield On
Screening Incl. Ground Att. over Barrier
Dz with limit (20/25)
Barrier Coefficients C1,2,3 3.0 20.0 0.0
Temperature (°F) 50
rel. Humidity (%) 70
Ground Absorption G 0.50
Wind Speed for Dir. (mph) 6.7
Roads (TNM)
Railways (FTA/FRA)
Aircraft (???)
Strictly acc. to AzB
Receiver Noise Levels
Name M. ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) (ft) (ft) (ft) (ft) R1 R1 75.2 -29.6 72.1 0.0 0.0 0.0 x Total 5.00 r 6080468.98 2248762.73 5.00 R2 R2 67.5 -37.3 64.5 0.0 0.0 0.0 x Total 5.00 r 6081006.30 2248678.53 5.00 R3 R3 71.9 -32.9 68.9 0.0 0.0 0.0 x Total 5.00 r 6080706.13 2248376.27 5.00 R4 R4 71.3 -33.5 68.3 0.0 0.0 0.0 x Total 5.00 r 6080399.12 2248347.66 5.00 Point Source(s)
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) Line Source(s)
Name M. ID Result. PWL Result. PWL' Lw / Li Operating Time Moving Pt. Src Height Day Evening Night Day Evening Night Type Value norm. Day Special Night Number Speed (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) Day Evening Night (mph) (ft) Name ID Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
Area Source(s)
Urban Crossroads, Inc.
200
1962
Name M. ID Result. PWL Result. PWL'' Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm. Day Special Night (ft) (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) CA1 CA1 122.5 17.7 17.7 80.5 -24.3 -24.3 PWL-Pt 117.7 8 r Name ID Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
CA1 CA1 8.00 r 6080294.43 2248708.77 8.00 0.00
6080769.65 2248713.88 8.00 0.00
6080771.00 2248521.30 8.00 0.00
6080779.24 2248521.36 8.00 0.00
6080780.23 2248381.36 8.00 0.00
6080226.89 2248377.49 8.00 0.00
6080227.57 2248531.69 8.00 0.00
6080296.32 2248533.08 8.00 0.00
Barrier(s)
Name Sel. M. ID Absorption Z-Ext. Cantilever Height Coordinates left right horz. vert. Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft) (ft) (ft) (ft)

8.00 r 6080779.47 2248381.36 8.00 0.00
6080227.71 2248375.44 8.00 0.00
Building(s)
Name Sel. M. ID RB Residents Absorption Height Coordinates Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
Ground Absorption(s)
Name Sel. M. ID G Coordinates
x y
(ft) (ft)
Contour(s)
Name Sel. M. ID OnlyPts Height Coordinates
Begin End x y z
(ft) (ft) (ft) (ft) (ft)
Vertical Area Source(s)
Name ID Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
Rail
Name Sel. M. ID Lw' Train Class Correct. Vmax
Day Night Track
(dBA) (dBA) (dB) (km(mph)
Sound Level Spectra
Name ID Type Oktave Spectrum (dB) Source
Weight. 31.5 63 125 250 500 1000 2000 4000 8000 A lin
Roads
Name Sel. M. ID Lme Count Data exact Count Data Speed Limit SCS Surface Gradient Mult. Reflection Day Evening Night DTV Str.class. M p (%) Auto Truck Dist. Dstro Type Drefl Hbuild Dist. (dBA) (dBA) (dBA) Day Evening Night Day Evening Night (mph) (mph) (dB) (%) (dB) (ft) (ft) RoadsGeo
Name Height Coordinates Dist LSlope
Begin End x y z Ground (ft) (%)
(ft) (ft) (ft) (ft) (ft) (ft)
Urban Crossroads, Inc.
201
1963
Appendix J: Level of Service (LOS) Screening Analysis
1964
This technical memorandum provides an evaluation of the development located at 2375 North Tustin Street (APN:372-642-31) (Project), in the City of Orange. The purpose of this analysis is to determine whether a level of service (LOS) analysis would be required for the proposed Project. This memo will evaluate the proposed Project using the City of Orange Traffic Impact Analysis (TIA) Guidelines for Vehicle Miles Traveled (VMT) and Level of Service Assessment (LOS), July 2020.

Project Description
The existing site area is 4.235 gross acres and is fully developed and currently contains a vacant 45,676 square foot (SF) Best Buy retail store building, surface parking lot, and landscaping. The existing onsite improvements were constructed in 2007. The entire site is relatively flat and is accessible via the existing driveway to North Tustin Avenue. The proposed Project will demolish the existing structure and improvements on the Project site and then develop 71 paired and detached residences, open space/recreation, and parking. The residential structures would be three-stories in height and range in size from approximately 2,000 square foot three-bedroom units to 2,066 square foot four-bedroom units that would be developed above two-car garages for each of the units. The 71 residences on the 4.235-acre site would result in a density of 16.76 units per acre. The Project site plan is shown in Figure 1.

The Project site has a General Plan land use designation of General Commercial (GC) that allows a maximum Floor Area Ratio (FAR) of 1.0 and is zoned Limited Business Tustin Redevelopment Project Area (C-TR). The General Plan states that the GC land use designation provides for a wide range of retail and service commercial uses and professional offices. Regional shopping centers, mid- and high-rise office projects, corridor shopping districts, and neighborhood corner stores are all permitted uses. The Limited Business Tustin Redevelopment Project Area zoning designation is intended to provide for limited commercial uses for a wide variety of goods and services.

Project Trip Generation
The trip generation for the proposed Project was analyzed in accordance with the Institute of Transportation Engineers (ITE) Trip Generation Manual, 11th Edition (2021). For the existing land use, ITE Land Use Code 863 (Electronics Superstore) was applied to represent the former Best Buy store. Although no trip credit was applied for the existing use in the LOS screening analysis, it was included to illustrate the number of trips previously generated by the site when the Best Buy was operational. Table 1 presents the trip generation for the former Best Buy store. As shown in Table 1, the Best Buy store was estimated to generate 1,875 daily trips, 16 AM peak hour trips, and 194 PM peak hour trips.

The proposed 71 dwelling units (DU) were analyzed using ITE Land Use Code 215, Single-Family Attached Housing. Table 2 presents the trip generation for the proposed Project. As shown in Table 2, the proposed To: City of Orange
From: Sina Salehipour, Mark Polunin, Chad Karns, EPD Solutions Inc.

Date: 9/29/2025
Site: 2375 North Tustin Street, Orange
Subject: Level of Service (LOS) Screening Analysis - North Tustin Street Residential Project - EPD#25-032
1965
North Tustin Street Residential Project
LOS Analysis Screening Memo
2 Project is expected to generate a total of 511 daily trips, including 34 AM peak hour and 40 PM peak hour trips.

Level of Service (LOS) Screening
Based on City’s guidelines outlined on page 4, an LOS analysis is required when the project generates more than 100 total peak hour vehicle trips during either the AM or PM peak hour. As shown in Table 2, the proposed Project would be expected to generate 34 AM peak hour trips and 40 PM peak hour trips.

Therefore, per the City’s TIA Guidelines, a full LOS analysis is not required for the proposed Project.

TIA Screening Results
The proposed Project was evaluated according to the City’s TIA guidelines to determine if the Project would require an LOS analysis. The proposed Project is anticipated to generate 34 AM peak hour trips and 40 PM peak hour trips, which is below the 100 peak hour trips threshold. Therefore, a LOS analysis would not be required for the proposed Project.
1966
North Tustin Street Residential Project
LOS Analysis Screening Memo
3 Figure 1: Project Site Plan
Source: C & V Consulting
1967
North Tustin Street Residential Project
LOS Analysis Screening Memo
4 Table 1: Former Best Buy Store Trip Generation
Table 2: Project Trip Generation
Units Daily In Out Total In Out Total
1000 Sq. Ft. GFA 41.05 0.25 0.09 0.34 2.13 2.13 4.25
1 Vacant Ex-Best Buy¹ 45.676 1000 Sq. Ft. GFA 1875 12 4 16 97 97 194 Pass By (Daily 0%, AM 0%, PM 40%) 0 0 0 0 -39 -39 -78
1875 12 4 16 58 58 116
Total Project Trip Generation 1875 12 4 16 97 97 194
¹Institute of Transportation Engineers, Trip Generation Manual, 11th Edition, 2021. Land Use Code 863 - Electronics Superstore (Average Rate) 863 Electronics Superstore¹
Project Trip Generation
Total Electronics Superstore Trip Generation
Scenario 1
AM Peak Hour PM Peak Hour
Land Use
Trip Rates Units Daily In Out Total In Out Total
Dwelling Units 7.20 0.15 0.33 0.48 0.32 0.25 0.57
1 Single-Family Attached Housing¹ 71 Dwelling Units 511 11 23 34 23 17 40 511 11 23 34 23 17 40
¹Institute of Transportation Engineers, Trip Generation Manual, 11th Edition, 2021. Land Use Code 215 - Single-Family Attached Housing (Average Rate) 215 Single-Family Attached Housing¹
Project Trip Generation
Total Project Trip Generation
AM Peak Hour PM Peak Hour
Land Use
Trip Rates
1968
Appendix K: VMT Analysis
1969
1970
2375 North Tustin Street
Vehicle Miles Traveled (VMT) Analysis
City of Orange
Prepared For
RE Consulting
[email protected]
Prepared By
3333 Michelson Drive, Suite 500
Irvine, CA 92612
(949) 794-1180
January 2026
1971
2375 North Tustin Street Project VMT Analysis
i

TABLE OF CONTENTS
1 Executive Summary ...................................................................................................................... 1 2 Introduction ................................................................................................................................... 4

2.1 Project Description.................................................................................................................. 4

2.2 Project Trip Generation ......................................................................................................... 4 3 VMT Background and Significance Threshold........................................................................... 7

3.1 City of Orange VMT Screening Criteria............................................................................... 7

3.2 VMT Significance Threshold ................................................................................................... 8 4 VMT Analysis................................................................................................................................ 9

4.1 VMT Screening Analysis ......................................................................................................... 9

4.2 OCTAM Model Configuration ............................................................................................. 12

4.3 Project-Generated VMT Evaluation ................................................................................... 13

4.4 Project’s Effect on VMT ....................................................................................................... 16 5 VMT Conclusion .......................................................................................................................... 18 List of Figures
Figure 1: Project Site Plan.................................................................................................................... 6 Figure 2: Density Calculation for Existing Residential Units within TAZ 573................................. 15 Figure 3: Roadways Selected to Calculate Daily VMT ................................................................... 16 List of Tables
Table 1: Former Best Buy Store Trip Generation ...............................................................................5 Table 2: Project Trip Generation.........................................................................................................5 Table 3: OCTAM VMT Analysis of Project – TAZ 573 .................................................................... 14 Table 4: Project’s Effect on VMT Results per City’s Guidelines...................................................... 17 Appendices
APPENDIX A – SCOPE OF WORK
APPENDIX B – OCTA TRANSIT INFORMATION
APPENDIX C – OCTAM INPUTS AND OUTPUTS
APPENDIX D – VMT REDUCTION CALCULATION AND SUPPORTING DOCUMENTS 1972
2375 North Tustin Street Project VMT Analysis
1 1 EXECUTIVE SUMMARY
This Vehicle Miles Traveled (VMT) Analysis has been prepared by EPD Solutions, Inc. to analyze the potential traffic related impacts of the proposed 2375 North Tustin Street Project (Project).

Project Description
The Project site is located at 2375 North Tustin Street (Assessor's Parcel Number [APN]: 372-642-31) in the City of Orange. The existing site area is 4.235 gross acres and is fully developed with a vacant 45,676-square-foot (SF) Best Buy retail store building, surface parking lot, and landscaping. The existing on-site improvements were constructed in 2007. The entire site is relatively flat and is accessible via the existing driveway to North Tustin Avenue. The proposed Project will demolish the existing structure and improvements on the Project site and then develop 71 paired and detached residences, open space/recreation, and parking. The residential structures would be three stories in height and range in size from approximately 2,008 square to 2,117 square feet and have three or four bedrooms.

Each residence would have a two-car garage. The 71 residences on the 4.235-acre site would result in a density of 16.76 dwelling units per acre (DU/ac).

Project Trip Generation
The proposed 71 dwelling units were analyzed based on the Institute of Transportation Engineers (ITE) Trip Generation Manual, 11th Edition (2021) as Single-Family Attached Housing. The proposed Project is expected to generate a total of 511 daily trips, including 34 AM peak hour trips and 40 PM peak hour trips.

Project VMT Screening Analysis
The City or Orange’s Guidelines provide the following screening criteria to identify if a project would be considered to have a less-than-significant impact on VMT and therefore could be screened out from further VMT analysis:

1. Is the Project within one-half mile of qualifying transit? Projects located within a Transportation Priority Area (TPA), defined as an area within one-half mile of qualifying transit, may be presumed to have a less-than-significant impact on VMT. The Project site is not located within a TPA based on the “NOCC+ (North Orange County Collaborative)” tool provided by the City of Orange that was last updated in 2021. However, the Orange County Transit Authority (OCTA) has since improved the frequency of Route 50 along N. Tustin Avenue to 15 minutes during peak hours, which became effective in November 2025. Therefore, the Project is located within a TPA under the most up-to-date transit service frequency.

While the Project is in a TPA, it does not meet all the requirements for Screening Criteria 1 since the Project provides more parking then required. Therefore, the project would not meet Screening Criteria

1. 2. Is the Project in a low VMT area?
Projects located within a low VMT-generating area that are consistent with the existing land use within that traffic analysis zone (TAZ) may be presumed to have a less-than-significant impact on VMT. The 1973
2375 North Tustin Street Project VMT Analysis
2 Project is not consistent with the existing land use. Therefore, it does not meet the requirements of Screening Criteria 2.

3. Is the Project a local serving land use?
Projects that propose local-serving land uses or generate fewer than 110 daily vehicle trips may be presumed to have a less-than-significant impact on VMT. The Project is not considered a local-serving land use and is anticipated to generate 511 daily trips, which is more than 110 daily vehicle trips.

Therefore, it does not meet the requirements of Screening Criteria 3.

The Project would not meet any of the City’s screening criteria; therefore, a full analysis of VMT was prepared for the Project.

Project-Generated VMT Evaluation
The proposed Project would develop 71 residential units on a 4.235 acre site. As defined by CAPCOA Measure T-1, “An acre in this context is defined as an acre of developed land, not including streets, school sites, parks, and other undevelopable land.” The net acreage of the site is 3.145 acres, which would result in a residential density of 22.57 units per net acre, and provides a reduction in VMT pursuant to Measure T-1: Increase Residential Density from the CAPCOA Handbook. • T-1 CAPCOA Measure T-1: Increase Residential Density. This measure accounts for the VMT reduction achieved by a project that has a higher density of dwelling units (DU) compared to the average residential density. Increased densities have been shown to affect the distance people travel and may result in greater options for the mode of travel they choose. Increasing residential density can result in shorter and fewer trips by single-occupancy vehicles. The residential density of the Project is calculated by dividing the total number of dwelling units (71 DUs) by the net acreage (3.145 acres) of the Project. Based on this, the residential density is calculated to be 22.57 units per net acre. The equation for the reduction in VMT is based on the residential density of the Project and the residential density of a typical development, or the residential density in the relevant TAZ1. o Using the residential density of TAZ 573 where the Project is located under existing conditions of 13.27 DU/ac (338 households2 in the 26.9 residential acres [25.47 net acres]3 within TAZ 573), the Project-generated VMT would be reduced by 15.4%.

With T-1 applied, the total VMT generated from TAZ 573 would reduce from 7,659 VMT to 6,479 VMT in under Base Year (2019) Conditions and 8,146 VMT to 6,890 VMT under Cumulative (2050) Conditions. The resulting Project VMT/Service Population values, would be 11.7% below the threshold under Project Baseline (2025) Conditions and 7.1% below the threshold under Cumulative (2050) 1 Per the CAPCOA Handbook, Increase Residential Density (T1), p. 71, the formula for VMT reduction is A = ((B - C) / C) × D, where A (0–30.0%) represents the percentage reduction in GHG emissions from project VMT in the study area, B (du/acre) is the residential density of the project development (dwelling units per acre), C is the residential density of a typical development (9.1 du/acre); however, the residential density of the relevant Transportation Analysis Zone (TAZ) should be used instead of this typical value, and D (-0.22) is the elasticity of VMT with respect to residential density. 2 Number of households provided by City of Orange.
3 Acreage is calculated using ArcGIS Pro.
1974
2375 North Tustin Street Project VMT Analysis
3 Conditions. Therefore, the proposed Project would result in a less-than-significant Project-generated VMT impact.

Project’s Effect on VMT
A boundary method analysis was conducted to evaluate the Project’s cumulative impacts on VMT. The Orange Citywide Boundary VMT/SP is 0.02% lower with the Project added under Project Baseline (2025) conditions and 0.03% lower with the Project added under Cumulative (2050) conditions.

Therefore, the Project’s effect on VMT would be less than significant. 1975
2375 North Tustin Street Project VMT Analysis
4 2 INTRODUCTION
This Vehicle Miles Traveled (VMT) Analysis has been prepared by EPD Solutions, Inc. to analyze the potential traffic related impacts for the proposed residential development located at 2375 North Tustin Street (Project). The scope of work for this VMT analysis was reviewed and approved by the City of Orange and is provided in Appendix A. The background for this analysis and Project description are discussed in detail below.

This VMT analysis is based on the requirements of the City of Orange Transportation Impact Analysis Guidelines for Vehicle Miles Traveled and Level of Service Assessment (City’s Guidelines), adopted by the City in July 2020.

2.1 Project Description
The proposed Project site is located at 2375 North Tustin Street (Assessor's Parcel Number [APN]: 372- 642-31) in the City of Orange. The existing site area is 4.235 gross acres and is fully developed with a vacant 45,676-square-foot (SF) Best Buy retail store building, surface parking lot, and landscaping.

The existing on-site improvements were constructed in 2007. The entire site is relatively flat and is accessible via the existing driveway to North Tustin Avenue. The proposed Project will demolish the existing structure and improvements on the Project site and then develop 71 paired and detached residences with open space/recreation and parking. The residential structures would be three stories in height and range in size from approximately 2,008 square feet to 2,117 square feet and would have three or four bedrooms (57 three-bedroom units and 14 four-bedroom units). Each residence would have a two-car garage. The 71 residences on the 4.235-acre site would result in a density of 16.76 dwelling units per acre (DU/ac) and a floor area ratio (FAR) of 0.79. The proposed Project site plan is shown in Figure 1.

The Project site currently has a General Plan land use designation of General Commercial (CG) that allows a maximum FAR of 1.0 and is zoned Limited Business Tustin Redevelopment Project Area (C-TR).

The General Plan states that the GC land use designation provides for a wide range of retail and service commercial uses and professional offices. Regional shopping centers, mid- and high-rise office projects, corridor shopping districts, and neighborhood corner stores are all permitted uses. The Limited Business Tustin Redevelopment Project Area zoning designation is intended to provide for limited commercial uses for a wide variety of goods and services.

The Project includes a General Plan Amendment to change the land use from GC to Medium Density Residential (MDR), which allows residential densities between 15 and 24 dwelling units per acre. The Project also includes a Zone Change to change the site zoning from C-TR to R3 (Multiple-Family Residential) with application of the Small Lot Subdivision Development Standards for fee simple duplex and detached residences.

2.2 Project Trip Generation
The trip generation for the proposed Project was analyzed in accordance with the Institute of Transportation Engineers (ITE) Trip Generation Manual, 11th Edition (2021). ITE Trip Generation Manual, 1976
2375 North Tustin Street Project VMT Analysis
5 12th Edition (2025) has been released at the time of this analysis. However, substantial progress on the Project was made before the ITE 12th Edition rates came out. Additionally, the trip generation rates from ITE 11th Edition represent a more conservative analysis. Therefore, trip generation rates from ITE 11th Edition are utilized for this analysis.

For the existing land use, ITE Land Use Code 863 (Electronics Superstore) was applied to represent the Best Buy store. Although no trip credit was applied for the existing use in this analysis, it was included to illustrate the number of trips previously generated by the site when the Best Buy was operational.

Table 1 presents the trip generation for the Best Buy store. As shown in Table 1, the Best Buy store was estimated to generate 1,875 daily trips, 16 AM peak hour trips, and 194 PM peak hour trips.

The proposed 71 dwelling units were analyzed using ITE Land Use Code 215, Single-Family Attached Housing. Table 2 presents the trip generation for the proposed Project. As shown in Table 2, the proposed Project is expected to generate a total of 511 daily trips, including 34 AM peak hour and 40 PM peak hour trips.

Table 1: Former Best Buy Store Trip Generation
Table 2: Project Trip Generation
Units Daily In Out Total In Out Total
1000 Sq. Ft. GFA 41.05 0.25 0.09 0.34 2.13 2.13 4.25
1 Vacant Ex-Best Buy¹ 45.676 1000 Sq. Ft. GFA 1875 12 4 16 97 97 194 Pass By (Daily 0%, AM 0%, PM 40%) 0 0 0 0 -39 -39 -78
1875 12 4 16 58 58 116
Total Project Trip Generation 1875 12 4 16 97 97 194
¹Institute of Transportation Engineers, Trip Generation Manual, 11th Edition, 2021. Land Use Code 863 - Electronics Superstore (Average Rate) 863 Electronics Superstore¹
‎
Project Trip Generation
Total Electronics Superstore Trip Generation
‎
AM Peak Hour PM Peak Hour
Land Use
Trip Rates
Units Daily In Out Total In Out Total
Dwelling Units 7.20 0.15 0.33 0.48 0.32 0.25 0.57
1 Single-Family Attached Housing¹ 71 Dwelling Units 511 11 23 34 23 17 40 511 11 23 34 23 17 40
¹Institute of Transportation Engineers, Trip Generation Manual, 11th Edition, 2021. Land Use Code 215 - Single-Family Attached Housing (Average Rate) 215 Single-Family Attached Housing¹
‎
Project Trip Generation
‎
Total Project Trip Generation
AM Peak Hour PM Peak Hour
Land Use
Trip Rates
1977
Figure 1: Project Site Plan CAR STOP

STOP THRU DRIVE THRU DRIVE STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP STOP
STOP
0 1" = 40'
20 40 80
VESTING TENTATIVE TRACT NO. 19392
2375 NORTH TUSTIN STREET

CITY OF ORANGE, COUNTY OF ORANGE

STATE OF CALIFORNIA
PLANNING LAND USE APPLICATION No. GPA25-0003 - DRC25-0019, ENV25-0001, MJSP25-0002, TTM25-0001, ZC25-0002, SMALL LOT ORDINANCE Figure 1: Project Site Plan
1978
2375 North Tustin Street Project VMT Analysis
7 3 VMT BACKGROUND AND SIGNIFICANCE

THRESHOLD
Senate Bill (SB) 743 was signed by Governor Brown in 2013 and required the Governor’s Office of Planning and Research (OPR) to amend the California Environmental Quality Act (CEQA) Guidelines to replace level of service (LOS) as the appropriate method for evaluating transportation impacts under CEQA. SB 743 specified that the new criteria should promote the reduction of greenhouse gas emissions, the development of multimodal transportation networks, and a diversity of land uses. The bill also specified that delay-based LOS could no longer be considered an indicator of a significant impact on the environment under CEQA. In response, the Natural Resources Agency amended the CEQA Guidelines to include Section 15064.3, Determining the Significance of Transportation Impacts. This section states that VMT is the most appropriate measure of a project’s transportation impacts and provides lead agencies with the discretion to choose the most appropriate methodology and thresholds for evaluating VMT. Section 15064.3(c) states that the provisions of the section shall apply statewide beginning on July 1, 2020.

3.1 City of Orange VMT Screening Criteria
The City’s Guidelines provide the following screening criteria to identify if a project would be considered to have a less-than-significant impact on VMT and therefore could be screened out from further VMT analysis:

1. Transit Priority Area (TPA) Screening.4 Projects located within a TPA may be presumed to have a less-than-significant impact on VMT.

2. Low VMT Area Screening. Projects located within a low VMT-generating area and consistent with the existing land uses within that traffic analysis zone (TAZ) may be presumed to have a less-thansignificant impact on VMT.

3. Project Type Screening. Projects that propose local-serving land use may be presumed to have a less-than-significant impact on VMT.
4 A TPA is defined as a half-mile area around an existing major transit stop or an existing stop along a highquality transit corridor per the definitions below.

Pub. Resources Code, § 21064.3 - ‘Major transit stop’ means a site containing an existing rail transit station, a ferry terminal served by either a bus or rail transit service, or the intersection of two or more major bus routes with a frequency of service interval of 15 minutes or less during the morning and afternoon peak commute periods.

Pub. Resources Code, § 21155 - For purposes of this section, a ‘high-quality transit corridor’ means a corridor with fixed route bus service with service intervals no longer than 15 minutes during peak commute hours.

Assembly Bill 2553 changed the definition of “major transit stop” from a 15-minute to 20-minute bus route service interval.
1979
2375 North Tustin Street Project VMT Analysis
8 If a project meets one of the criteria above, then the VMT impact of the Project would be considered less-than-significant and no further analysis of VMT would be required.

3.2 VMT Significance Threshold
Projects that do not meet any screening criteria should complete VMT analysis and forecasting through the Orange County Transportation Analysis Model (OCTAM) to determine if they have a significant VMT impact. This analysis should include both ‘project-generated VMT’ for the project TAZ (or TAZs) and ‘project effect on VMT’ estimates. VMT thresholds provided below are to be applied to determine potential project-generated VMT impacts and project’s effect on VMT impacts.

A project would result in a significant project-generated VMT impact if either of the following conditions are satisfied:
• The baseline project-generated VMT per service population exceeds the City of Orange General Plan Buildout VMT per service population; or
• The cumulative project-generated VMT per service population exceeds the City of Orange General Plan Buildout VMT per service population
The project’s effect on VMT would be considered significant if it resulted in either of the following conditions being satisfied:
• The baseline link-level boundary Citywide VMT per service population increases under the plus project condition compared to the no project condition; or • The cumulative link-level boundary Citywide VMT per service population increases under the plus project condition compared to the no project condition.

Please note that the cumulative “no project” shall reflect the adopted Regional Transportation plan/Sustainable Communities Strategy (RTP/SCS); as such, if a project is consistent with the Southern California Association of Governments (SCAG) RTP/SCS (Connect SoCal), then the cumulative impacts (project effect on VMT) shall be considered less than significant subject to consideration of other substantial evidence.

1980
2375 North Tustin Street Project VMT Analysis
9 4 VMT ANALYSIS

4.1 VMT Screening Analysis
The applicability of each screening criteria to the Project is discussed below.

Screening Criteria 1 – Transit Priority Area (TPA) Screening Projects located within a TPA may be presumed to have a less-than-significant impact on VMT absent substantial evidence to the contrary. This presumption may NOT be appropriate if the project:

1. Has an FAR of less than 0.75;

2. Includes more parking for use by residents, customers, or employees of the project than required by the City;

3. Is inconsistent with the applicable Sustainable Communities Strategy (as determined by the lead agency, with input from the Southern California Association of Governments [SCAG]); or

4. Replaces affordable residential units with a smaller number of moderate- or high-income residential units.

Based on the “NOCC+ (North Orange County Collaborative)” tool provided by the City of Orange that was last updated in 2021, the Project site located at 2375 North Tustin Street in the City of Orange is not located within a TPA. However, the NOCC+ user guide also instructs the analyst to confirm transit service at the time of analysis. Thus, current transit services were reviewed to confirm if the Project is located within a TPA.

Public transportation is provided to the City by the Orange County Transportation Authority (OCTA).

There are several existing bus routes along N. Tustin Avenue, including Routes 42, 46, 50, 71, and 167.

The closest OCTA bus stop is located across from the Project site on N. Tustin Avenue. As shown in the transit information provided in Appendix B, OCTA improved the frequency of Route 50 along N. Tustin Avenue to 15 minutes during peak hours, which became effective in November 2025. Therefore, the Project is located within a TPA under the most up-to-date transit service frequency.

However, the Project does not satisfy all other required TPA screening criteria:
• Floor Area Ratio (FAR): As previously described in Section 2.1, the Project has a proposed FAR of

0.79, exceeding the 0.75 minimum requirement.
• Parking: The City of Orange requires a total of 174 parking stalls for the Project. o The Project provides a total of 179 parking stalls, which is 5 more parking stalls than the amount required by the City. Therefore, the Project does not meet this screening criteria. • SCS Consistency: The Project is consistent with the SCS as listed below:
o The Project would develop 71 townhome residences, which would generate between 178 and 224 residents. According to the California Department of Finance, the City had a population of 139,724 in 2025 with 48,301 housing units. The increase in 71 housing units would equate to a

0.15 percent increase in housing units within the City and the increase of 224 residents would equate to a 0.16 percent increase in population. Compared to growth projections, the proposed 1981
2375 North Tustin Street Project VMT Analysis
10 71 residences equates to 3.3 percent of the SCAG projected increase in households in the City between 2024 and 2050.
o The City’s 2021-2029 Housing Element Update details that the City has a Regional Housing Needs Allocation (RHNA) of 3,936 units. Of the RHNA units, 677 (17.1%) would be for moderate income households and 1,588 units (40.4%) would be for above moderate income households.

The proposed 71 residences equates to 1.8 percent of the City’s total RHNA allocation, and 3.1 percent of the City’s moderate and above moderate income household RHNA allocations.

Overall, the Project's generation of housing is consistent with growth projections in the SCS. o In addition, vehicle trips included in the SCS is based on the Project site’s existing General Plan land use designation of General Commercial (GC) that allows a maximum Floor Area Ratio (FAR) of 1.0 and emissions generated by the existing 45,676 square foot retail store building that was constructed in 2007. The former Best Buy store generated approximately 1,875 daily vehicle trips and the proposed 71 residential units under the proposed Project would generate approximately 511 daily vehicle trips. Thus, the proposed Project would not result in growth in vehicle trips or related emissions and would not conflict with the SCS. • Affordable Housing Displacement: The Project site does not include existing residential units and does not result in the displacement of any affordable housing.

Therefore, while the Project is in a TPA, it does not meet all the requirements for Screening Criteria 1.

The Project would not meet Screening Criteria 1 because it includes 5 more parking stalls than the amount required by the City.

Screening Criteria 2 – Low VMT Area Screening
The City’s Guidelines utilize the “NOCC+” tool to identify low VMT-generating areas for screening purposes. Under these guidelines, projects located within areas that generate VMT below the City of Orange General Plan Buildout VMT per service population (hereafter referred to as VMT/SP) may be presumed to have a less-than-significant VMT impact and may be screened from detailed VMT analysis.

However, the land use assumptions within the NOCC+ tool and screening maps available for this site are inconsistent with the proposed Project, as the historical use of the site was not residential.

Additionally, a preliminary review of the OCTAM model shows the project is not located in a low VMT area. Therefore the Project would not meet Screening Criteria 2.

Screening Criteria 3 – Project Type Screening
Some project types have been identified as having the presumption of a less-than-significant impact.

The following uses can be presumed to have a less-than-significant impact absent substantial evidence to the contrary as their uses are local serving in nature:
• Local-serving K-12 schools
• Local parks
• Day care centers
• Local-serving retail uses less than 50,000 square feet, including:
o Gas stations
o Banks
1982
2375 North Tustin Street Project VMT Analysis
11 o Restaurants
o Shopping Center
• Local-serving hotels (e.g. non-destination hotels)
• Student housing projects on or adjacent to a college campus • Local-serving assembly uses (places of worship, community organizations) • Community institutions (public libraries, fire stations, local government) • Affordable, supportive, or transitional housing
• Assisted living facilities
• Senior housing (as defined by HUD)
• Local serving community colleges that are consistent with the assumptions noted in the RTP/SCS • Projects generating less than 110 daily vehicle trips o This generally corresponds to the following “typical” development potentials:
 11 single family housing units
 16 multi-family, condominiums, or townhouse housing units  10,000 SF of office
 15,000 SF of light industrial
 63,000 SF of warehousing
 79,000 SF of high cube transload and short-term storage warehouse As previously analyzed in Section 2.2, the proposed residential Project (71 dwelling units) is expected to generate a total of 511 daily trips, including 34 AM peak hour trips and 40 PM peak hour trips. As the Project is neither a local-serving use, as defined by the City, nor does it generate fewer than 110 average daily trips, it does not meet Screening Criteria 3 for project type screening.

The Project would not meet any of the City’s screening criteria; therefore, a full analysis of VMT was prepared for the Project.
1983
2375 North Tustin Street Project VMT Analysis
12 4.2 OCTAM Model Configuration
The City’s Guidelines require the use of OCTAM, which incorporates the most recent roadway circulation and land use data from the City’s current General Plan, for preparation of VMT analyses. OCTAM includes validated scenarios for the model’s Base Year (2019) and Cumulative Year (2050).

The Project is located within TAZ 573. Prior to conducting the VMT model runs, the OCTAM roadway network near the Project site was reviewed, and no changes were necessary for the roadway network.

The VMT for Base and Cumulative Year With Project conditions was derived under the following steps:
• The original land use from the Project TAZ 573 was moved to an adjacent TAZ, TAZ 572. • The Project land use was then added to the isolated TAZ 573, where the Project is located, so that the Project-generated VMT can be identified:
o 71 DUs were added to TAZ 573.
o The total population and employed population for the Project was calculated based on the existing household occupancy of TAZ 573:
 The existing TAZ 573 contains 337 DUs and 1126 residents, which equates to an average household occupancy of 3.34 residents/DU.
 Similarly, TAZ 573 contains 337 DUs and 833 employed residents, which equates to an average rate of 2.47 employed residents/DU.
o Using the existing rates, a population of 237 residents and an employed population of 175 residents were added to TAZ 573.

All OCTAM VMT inputs can be found in Appendix C. With the land use inputs noted above, OCTAM was run for the Base Year (2019) and Cumulative Year (2050) under No-Project and With-Project conditions (i.e., four full Model runs).

The total Origin-Destination (OD) VMT of the Project TAZ was evaluated using the OCTAM VMT postprocessor from the OCTAM Base Year (2019) and Cumulative Year (2050) With-Project Model runs. To determine OD VMT/Service Population (VMT/SP), the total OD VMT of the Project TAZ is divided by the total Service Population (Service Population = Population + Employment + Enrollment) of the Project TAZ. The 2025 VMT/SP of the Project TAZ was interpolated using linear interpolation between the 2019 and 2050 Model outputs.

All OCTAM VMT outputs can be found in Appendix C.
1984
2375 North Tustin Street Project VMT Analysis
13 4.3 Project-Generated VMT Evaluation
The applicable threshold for the City of Orange is based on the City of Orange General Plan Buildout VMT per service population. The City’s VMT/SP threshold of 31.3 VMT/SP under Cumulative Year (2050) was obtained using the NOCC+ Tool.

The baseline VMT for the Project TAZ (TAZ 573) was determined using the OCTAM VMT post-processor results using linear interpolation between the 2019 and 2050 With-Project model outputs.

Due to the increased density of residential units proposed by the Project, Measure T-1: Increase Residential Density from the California Air Pollution Control Officers Association (CAPCOA) Handbook for Analyzing Greenhouse Gas (GHG) Emission Reductions, Assessing Climate Vulnerabilities, and Advancing Health and Equity (October 2024) was utilized to adjust the baseline VMT results to more accurately analyze the Project.

The proposed Project would develop 71 residential units on a 4.235-acre site. As defined by CAPCOA Measure T-1, “An acre in this context is defined as an acre of developed land, not including streets, school sites, parks, and other undevelopable land.” As shown in Figure 1: Project Site Plan, the net acreage of the site, which excludes Lot #A, #B and #C totaling 1.09 acres from the 4.235-acre site, would be 3.145 acres. The net density of the Project is calculated to be 22.57 units per net acre, and provides a reduction in VMT pursuant to CAPCOA Measure T-1, as detailed below:
• T-1 CAPCOA Measure T-1: Increase Residential Density. This measure accounts for the VMT reduction achieved by a project that has a higher density of dwelling units (DU) compared to the average residential density. Increased densities have been shown to affect the distance people travel and may result in greater options for the mode of travel they choose. Increasing residential density can result in shorter and fewer trips by single-occupancy vehicles. The residential density of the Project is calculated by dividing the total number of dwelling units (71 DUs) by the net acreage (3.145 acres) of the Project. Based on this, the residential density is calculated to be 22.57 units per net acre. The equation for the reduction in VMT is based on the residential density of the Project and the residential density of a typical development, or the residential density in the relevant TAZ5. o Using the residential density of TAZ 573 where the Project is located under existing conditions of 13.27 DU/ac (338 households6 in the 26.9 residential acres [25.47 net acres]7 within TAZ 573) as shown in Figure 2: Density Calculation for Existing Residential Units within TAZ 573, the Project-generated VMT would be reduced by 15.4%.

The supporting documentation and calculation for the VMT reduction can be found in Appendix D. 5 Per the CAPCOA Handbook, Increase Residential Density (T1), p. 71, the formula for VMT reduction is A = ((B - C) / C) × D, where A (0–30.0%) represents the percentage reduction in GHG emissions from project VMT in the study area, B (du/acre) is the residential density of the project development (dwelling units per acre), C is the residential density of a typical development (9.1 du/acre); however, the residential density of the relevant Transportation Analysis Zone (TAZ) should be used instead of this typical value, and D (-0.22) is the elasticity of VMT with respect to residential density. 6 Number of households in TAZ 573 is provided by City of Orange. 7 Acreage is calculated using ArcGIS Pro.
1985
2375 North Tustin Street Project VMT Analysis
14 The Project’s VMT analysis results, applying the 15.4% reduction of total VMT, for the Project (TAZ 573) using OCTAM are shown in Table 3, OCTAM VMT Analysis of Project – TAZ 573. As shown in Table 3, the Project’s VMT/SP would be 11.7% below the threshold under Project Baseline (2025) Conditions and 7.1% below the threshold under Cumulative (2050) Conditions. Therefore, the proposed Project would result in a less-than-significant Project-generated VMT impact.

Table 3: OCTAM VMT Analysis of Project – TAZ 573
1Source: NOCC+ Tool
Base Year 2019 Baseline 2025 Cumulative 2050
Project TAZ 573 Zone Total OD VMT 7,659 7,753 8,146
T-1: CAPCOA Measure T-1: Increase Residential Density VMT Reduction -15.4% -15.4% -15.4% Project TAZ 573 Zone Total OD VMT acounting for
T-1: CAPCOA Measure T-1: Increase Residential Density 6,479 6,558 6,890 TAZ 573 Population 237 237 237
TAZ 573 Employment 0 0 0
TAZ 573 Enrollment 0 0 0
TAZ 573 Service Population 237 237 237
Project TAZ 573 VMT/SP 27.3 27.7 29.1
VMT/SP Threshold (City of Orange General Plan Buildout VMT/SP)1 % Above/Below Threshold acounting for
T-1: CAPCOA Measure T-1: Increase Residential Density - -11.7% -7.1% Impact? - No No

31.3 1986
237 5 North Tustin Street Project
Legend
c:::J Traffic Zone
c:::J Project Boundary
Non-Residential
Component ( l .47 ac.)
[Z] Residential Component
(25.47 net ac.)* ...._ ______________ ..J *26.94 gross ac.

E I p I D SOLUTIONS, INC
0 Figure 2: Density Calculation for Existing
Residential Units within TAZ 573
Created with Vertical © 2025 Nearmap US, Inc.
550 1,100
US Feet
1987
2375 North Tustin Street Project VMT Analysis
16 4.4 Project’s Effect on VMT
According to the City’s Guidelines, if a project causes the link-level boundary Citywide VMT per service population within the City to be higher than the No Project scenario under baseline or cumulative conditions, the project’s effect on VMT would be considered significant.

A boundary method analysis was conducted to evaluate the Project’s cumulative effect on VMT. The daily VMT within the City is calculated by the sum of total link-based VMT of all the roadways within the City. The roadways selected to calculate daily VMT are shown below in Figure 3.

Figure 3: Roadways Selected to Calculate Daily VMT
To calculate the daily VMT/SP, the total daily VMT within the City is divided by the total service population of the City. The total service population within the City is calculated by the sum of total population and employees of all the TAZs within the City.

The Project’s effect on VMT results are shown in Table 4. The citywide No Project VMT/SP for the City of Orange is 14.117 for Base Year (2019) and 14.514 for Cumulative Year (2050). Therefore, the City’s threshold of significance for Project Baseline (2025) was interpolated to be 14.197 VMT/SP.

As shown in Table 4, the Orange Citywide Boundary VMT/SP is 0.02% lower with the Project added under Project Baseline (2025) Conditions and 0.03% lower with the Project added under Cumulative (2050) Conditions. Therefore, the Project’s effect on VMT would be less than significant. 1988
2375 North Tustin Street Project VMT Analysis
17 Table 4: Project’s Effect on VMT Results per City’s Guidelines Base Year 2019 Baseline 2025 Cumulative Year 2050
Citywide Boundary VMT With Project 4,435,908 4,504,990 4,792,829 Citywide Population With Project 143,228 143,822 146,298 Citywide Employment With Project 129,924 131,703 139,118 Citywide Enrollment With Project 41,140 41,871 44,917
Citywide Service Population With Project 314,292 317,397 330,333 With Project Citywide Boundary VMT/SP 14.114 14.194 14.509 Citywide Boundary VMT No Project 4,433,377 4,502,607 4,791,066 Citywide Population No Project 142,991 143,585 146,061
Citywide Employment No Project 129,924 131,703 139,118
Citywide Enrollment No Project 41,140 41,871 44,917
Citywide Service Population No Project 314,055 317,160 330,096 No Project Citywide Boundary VMT/SP 14.117 14.197 14.514 % Above/Below Threshold - -0.02% -0.03%
Impact? - No No
1989
2375 North Tustin Street Project VMT Analysis
18 5 VMT CONCLUSION
This VMT Analysis has been prepared to analyze the potential transportation related impacts of the proposed 2375 North Tustin Street Project.

The City or Orange’s Guidelines provide the following screening criteria to identify if a project would be considered to have a less-than-significant impact on VMT and therefore could be screened out from further VMT analysis:

1. Is the Project within one-half mile of qualifying transit?

2. Is the Project in a low VMT area?

3. Is the Project a local serving land use?
The Project would not meet all of the City’s screening criteria; therefore, a full analysis of VMT was prepared for the Project.

The proposed Project would result in a residential density of 22.57 units per net acre, which has a higher density than typical residential projects and provides for a reduction in VMT pursuant to Measure T-1:

Increase Residential Density from the CAPCOA Handbook. Therefore, the proposed Project VMT/SP would is on the following calculation:
• T-1 CAPCOA Measure T-1: Increase Residential Density. This measure accounts for the VMT reduction achieved by a project that has a higher density of dwelling units (DU) compared to the average residential density. Increased densities have been shown to affect the distance people travel and may result in greater options for the mode of travel they choose. Increasing residential density can result in shorter and fewer trips by single-occupancy vehicles.

The residential density of the Project is calculated by dividing the total number of dwelling units (71 DUs) by the net acreage (3.145 acres) of the Project. Based on this, the residential density is calculated to be 22.57 units per net acre. The equation for the reduction in VMT is based on the residential density of the Project and the residential density of a typical development, or the residential density in the relevant TAZ8.
o Using the residential density of TAZ 573 where the Project is located under existing conditions of 13.27 DU/ac (338 households in the 26.9 residential acres [25.47 net acres] within TAZ 573), the Project-generated VMT would be reduced by 15.4%.

The Project’s VMT analysis results, applying the 15.4% reduction of total VMT, would be 11.7% below the threshold under Project Baseline (2025) Conditions and 7.1% below the threshold under Cumulative 8 Per the CAPCOA Handbook, Increase Residential Density (T1), p. 71, the formula for VMT reduction is A = ((B - C) / C) × D, where A (0–30.0%) represents the percentage reduction in GHG emissions from project VMT in the study area, B (du/acre) is the residential density of the project development (dwelling units per acre), C is the residential density of a typical development (9.1 du/acre); however, the residential density of the relevant Transportation Analysis Zone (TAZ) should be used instead of this typical value, and D (-0.22) is the elasticity of VMT with respect to residential density.
1990
2375 North Tustin Street Project VMT Analysis
19 (2050) Conditions. Therefore, the proposed Project would result in a less-than-significant Projectgenerated VMT impact.

The Orange Citywide Boundary VMT/SP is 0.02% lower with the Project added under Project Baseline (2025) Conditions and 0.03% lower with the Project added under Cumulative (2050) Conditions.

Therefore, the Project’s effect on VMT would be less than significant. 1991
2375 North Tustin Street Project VMT Analysis
APPENDIX A – SCOPE OF WORK
1992
Please see the comment below from Maria Prodo Flores regarding the VMT Scoping Agreement.

Thank you,
Monique
From: Maria Prado Flores <[email protected]>
Sent: Wednesday, November 5, 2025 4:49 PM
To: Monique Schwartz <[email protected]>
Subject: RE: 2375 N. Tustin Street - VMT Comments (GPA2025-0003 et al) Hi Monique,
Attached is the VMT scoping agreement that was submitted to the traffic division. I only have one comment, for #2 the applicant shall also evaluate project generated VMT/SP in the future year 2050 condition. The attached document also has the same comment.

The applicant does not need to resubmit the scoping agreement, they can continue with the VMT analysis as long as they also evaluate project generated VMT/SP in the future year 2050 condition.

Maria Flores
Assistant Engineer
Public Works – Traffic Division
300 E. Chapman Ave | Orange, CA 92866
Direct: (714) 744-5541 | www.cityoforange.org
1993
Urban Planning ■ Due Diligence ■ Entitlements ■ CEQA/NEPA ■ Development Services ■ Management ■ Public Outreach 3333 Michelson Drive, Suite 500 ■ Irvine, Calif. 92612
949.794.1180 ■ [email protected]
Date: October 23, 2025
Prepared by: Simon Lin, EIT, Alex J. Garber, EPD Solutions Inc To: Maria Flores, City of Orange Public Works – Traffic Division Site: 2375 North Tustin Street, Orange (APN: 372-642-31) Subject: Vehicle Miles Traveled Scope of Work for North Tustin Street Residential Project In response to comments received on the draft VMT analysis prepared for this Project, this memo outlines the proposed scope of work for the Vehicle Miles Traveled (VMT) analysis for the proposed residential development located at 2375 North Tustin Street (APN: 372-642-31) (Project), in the City of Orange. The Project description and proposed scope of work are discussed in detail below.

Project Name: North Tustin Street Residential Project
Project Address: 2375 North Tustin Street, Orange, CA, 92865 Project Description: The existing site area is 4.235 gross acres and is fully developed with a vacant 45,676 square foot (SF) Best Buy retail store building, surface parking lot, and landscaping. The existing onsite improvements were constructed in 2007 and were operational through October 2023. The entire site is relatively flat and is accessible via the existing driveway to North Tustin Avenue. The proposed Project will demolish the existing structure and improvements on the Project site and then develop 71 paired and detached residences, open space/recreation, and parking. The residential structures would be three-stories in height and range in size from approximately 2,008 square foot three-bedroom units to 2,117 square foot four-bedroom units that would be developed above two-car garages for each of the units. The 71 residences on the 4.235-acre site would result in a density of 16.76 units per acre. The Project site plan is shown in Figure 1.

Trip Generation and VMT Screening: The Trip Generation and VMT Screening Analysis of the Project was evaluated in North Tustin Street Residential VMT Screening Memo submitted to City of Orange dated September 29, 2025. Upon the City of Orange’s review of the memo, the LOS analysis was accepted and a full VMT analysis was requested.

Vehicle Miles Traveled Analysis:

The Project will conduct a VMT analysis using the Orange County Transportation Analysis Model (OCTAM).

The following tasks will be undertaken to prepare the VMT analysis:

1. In order to evaluate base year (2019) and the future year (2050) with-Project conditions, EPD will modify the OCTAM model by updating the Project’s socio-economic data (SED) to input Project data into the existing TAZ 573, where the Project is located. The original land use in TAZ 573 is moved to the adjacent TAZ (TAZ 572), in order to isolate TAZ 573 so that the Project-generated VMT can be identified.
1994
North Tustin Street Residential Project
Vehicle Miles Traveled Analysis Scope of Work
2 Four full model runs will be conducted to evaluate VMT for both the base year (2019) and the future year (2050), under both with-Project and without Project conditions. The proposed Model Land Use Inputs for the proposed Project is provided in Attachment A.

2. The model output will be post-processed to calculate the total daily VMT/Service Population (SP) for analysis year 2025, which will be interpolated from the base year (2019) and buildout year (2050) model runs. Project VMT impacts will be determined using the significance criteria outlined in the City's guidelines.

3. The Project’s effect on VMT will be evaluated by calculating the Citywide link-level VMT per Service Population for without and with Project conditions. The Project is considered to have a significant impact if the link level VMT per Service Population is increased under with Project conditions.

4. If a significant VMT impact is identified, EPD will identify appropriate mitigation measures such as change in the Project description, transportation demand management (TDM) measures, or participation in an impact fee and/or exchange program (if any applicable to the Project) to reduce VMT to achieve acceptable levels.

We appreciate your review of this information. Upon completion of your review, please forward any comments or approval of this methodology to [email protected]. If you have any questions, please do not hesitate to contact us by e-mail or on (949) 794-1180.

City Approval of Scope of Work:

Signature
Name
Date
311
1995
North Tustin Street Residential Project
Vehicle Miles Traveled Analysis Scope of Work
3 Figure 1: Project Site Plan
1996
North Tustin Street Residential Project
Vehicle Miles Traveled Analysis Scope of Work
4 ATTACHMENT A – PROPOSED MODEL LAND USE INPUTS
1997
North Tustin Street Residential Project
Vehicle Miles Traveled Analysis Scope of Work
5 Proposed OCTAM Model Land Use Inputs
Model Run SED 2375 North Tustin Street Project, City of Orange TAZ 573
Dwelling Units to add to TAZ 71
1998
North Tustin Street Residential Project
Vehicle Miles Traveled Analysis Scope of Work
6 No Project 2019
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 109 109 66 27 98605 582 697 24 0 0
573 1126 1126 833 337 95733 537 402 82 0 0
Plus Project 2019
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1235 1235 899 364 98605 1119 1099 106 0 0
573 237 237 175 71 95733 0 0 0 0 0
Plus Project - No project
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1126 1126 833 337 0 537 402 82 0 0
573 -889 -889 -658 -266 0 -537 -402 -82 0 0
No Project 2050
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 99 99 61 27 98605 634 715 22 0 0
573 1109 1109 820 387 95733 474 405 76 0 0
Plus Project 2050
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1208 1208 881 414 98605 1108 1120 98 0 0
573 203 203 150 71 95733 0 0 0 0 0
Plus Project - No project
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1109 1109 820 387 0 474 405 76 0 0
573 -906 -906 -670 -316 0 -474 -405 -76 0 0
1999
2375 North Tustin Street Project VMT Analysis
APPENDIX B – OCTA TRANSIT INFORMATION
2000
EFFECTIVE NOVEMBER 9, 2025
EFECTIVO 9 DE NOVIEMBRE 2025
e BUS BOOK

RIDE OC BUS

WITH WAVE
Learn more at
OCBus.com/Wave
Introducing Wave by OCTA. It’s a smarter, easier way to pay that can help you save money when riding OC Bus. Choose from the Wave Card or the Wave Mobile App now available for download.

Paper passes are no longer sold onboard buses, but existing passes will be accepted for at least 6 months. Cash is still accepted with exact change. 2001
The OC Bus Service Change Improvements summarize adjustments designed to improve service reliability, expand access to key destinations, and better connect to regional transit. Updates include frequency improvements, route realignments to destinations such as the Buena Park Metrolink Station and the Brea Mall, and schedule adjustments to enhance on-time performance across the system.

Highlights of This Service Change
• Frequency improvements on Routes 25, 33, 50, 53, 59, and 143. • Route 1 realigned to discontinue the Warner Loop, reducing delays. • Routes 29 and 129 realigned to end at the Buena Park Metrolink Station (previously La Habra). • Routes 59 and 129 realigned to end at the Brea Mall (previously La Palma).

Route 123 realigned to end at Anaheim Canyon Station stalls (previously La Palma Ave). • Minor schedule adjustments on multiple routes to improve reliability.

Minor Schedule Adjustments
The following routes will receive adjustments to improve on-time performance:

Routes: 1, 29, 42, 43, 56, 59, 60, 66, 129, 143, 553.

Route 1
All Days: Discontinued the Warner Loop. Use southbound PCH nearside Warner and northbound PCH farside Warner.

Weekends: Regular schedule (removed extended summer schedule on weekends only).

Route 25
Weekdays: Improve frequency of service from 50 to 30 minutes during peak hours.

Route 29
All Days: Realigned route to end at the Buena Park Metrolink Station (previously La Habra).

Weekdays: Reduced frequency to 30 minutes all day.

Route 33
Weekdays: Improved frequency to 30 minutes all day.

Weekends: Improved frequency to 55 minutes all day.

Route 50
Weekdays: Improved frequency to 15 minutes during peak hours.

Route 53
Weekends: Improved frequency to 15 minutes (short alignment) / 30 minutes (long alignment) from 6 a.m. to 6 p.m.

Route 54
Weekdays and Saturdays: Implemented detour at Santiago Canyon College.

Route 59
All Days: Extended route to Brea Mall (previously La Palma Ave). Realigned long trips to UCI on weekends.

Weekdays: Improved frequency to 30 minutes all day.

Route 123
Weekdays: Realigned to end at Anaheim Canyon Station stalls (previously La Palma Ave).

Route 129
All Days: Extended route to Buena Park Metrolink Station (previously La Habra). Realigned route to end at the Brea Mall (previously La Palma Ave).

Weekdays: Improved frequency to 30 minutes.

Route 143
Weekends: Improved frequency to 45 minutes.

Route 529
Weekdays: Reduced frequency to 30 minutes all day.

Bus Service Change Improvements – Effective November 9, 2025 2002
Effective November 9, 2025 | Orange County Transportation Authority ORANGE

ANAHEIM

GARDEN GROVE

CYPRESS

STANTON

LOS ALAMITOS
Heim
Canal
Tustin 71; RTA 200
Glassell 59
Main 53, 553
Douglass
State College 57
Anaheim 47, ART Haster 47
Euclid 37
Brookhurst 35
Magnolia 33
Beach 29, 529
Knott 25
Valley View 123
Los Alamitos 46
Bloomeld
Willow
Katella
Taft
Katella
46 LONG BEACH
Harbor 43, 83, 543, 553; ART
METRO 460; RTA 200
Honda Center
Anaheim Convention Center
Angel Stadium
of Anaheim

VA HOSPITAL

CSULB AREA
1, 50, 60; LBT: 41, 81, 91, 92, 93, 94,
171 ZAP 176; METRO 577x
East Shuttle Area
Lincoln Park-and-Ride
ARTIC
50, 53, 553; ART;

METROLINK/AMTRAK, GREYHOUND, FLIX
Studebaker
LBT 173
METRO = Los Angeles Metro | RTA = Riverside Transit Agency LBT = Long Beach Transit | ART = Anaheim Resort Transit

THE VILLAGE

AT ORANGE
42, 46, 50, 71, 167; RTA 200
Numbers on streets indicate transfers. Números en la calle indican transbordos.

Scheduled
Departure
Regular
Routing
LEGEND

LEYENDA MAP NOT TO SCALE
N
Route 050/061125
Bell
ower
7th St
CSULB Pacic
Coast Hwy 1
VA Hospital Channel
OCTA ADA Certication Center
Trenton

DISNEYLAND
43, 83, 543, 553; L.A. METRO 460; RTA 200, ART
Meats 167; RTA 200

Page 70 ends

50 Long Beach to Orange
via Katella Ave
2003
Build an ebusbook at ocbus.com/ebusbook | Effective November 9, 2025 Page 71 50 Long Beach to Orange
via Katella Ave
Monday-Friday
EASTBOUND To: Orange
Monday-Friday
EASTBOUND To: Orange (cont.)
7th & ChannelKatella &Los AlamitosKatella & BeachKatella & BrookhurstKatella & HarborAnaheim Regional Transportation IntermodalCenter (ARTIC)Katella & GlassellVillage At Orange Zone 2 4:04 4:13 4:24 4:30 4:39 4:50 4:55 5:08
4:29 4:38 4:49 4:55 5:04 5:15 5:20 5:33
4:49 4:58 5:09 5:15 5:24 5:35 5:40 5:53
5:09 5:18 5:29 5:35 5:44 5:55 6:00 6:13
5:29 5:38 5:49 5:55 6:04 6:15 6:20 6:33
5:44 5:53 6:04 6:10 6:19 6:30 6:35 6:48
5:48 5:59 6:14 6:22 6:34 6:46 6:52 7:07
6:03 6:14 6:29 6:37 6:49 7:01 7:07 7:22
6:18 6:29 6:44 6:52 7:04 7:16 7:22 7:37
6:33 6:44 6:59 7:07 7:19 7:31 7:37 7:52
6:48 6:59 7:14 7:22 7:34 7:46 7:52 8:07
7:00 7:12 7:28 7:37 7:49 8:02 8:09 8:24
7:15 7:27 7:43 7:52 8:04 8:17 8:24 8:39
7:30 7:42 7:58 8:07 8:19 8:32 8:39 8:54
7:45 7:57 8:13 8:22 8:34 8:47 8:54 9:09
8:00 8:12 8:28 8:37 8:49 9:02 9:09 9:24
8:15 8:27 8:43 8:52 9:04 9:17 9:24 9:39
8:30 8:42 8:58 9:07 9:19 9:32 9:39 9:54
8:45 8:57 9:13 9:22 9:34 9:47 9:54 10:09
9:00 9:12 9:28 9:37 9:49 10:02 10:09 10:24
9:30 9:42 9:58 10:07 10:19 10:32 10:39 10:54
9:58 10:11 10:28 10:37 10:49 11:02 11:09 11:26
10:28 10:41 10:58 11:07 11:19 11:32 11:39 11:56
10:58 11:11 11:28 11:37 11:49 12:02 12:09 12:26
11:26 11:39 11:57 12:06 12:18 12:32 12:39 12:56
11:56 12:09 12:27 12:36 12:48 1:02 1:09 1:26
12:26 12:39 12:57 1:06 1:18 1:32 1:39 1:56
12:56 1:09 1:27 1:36 1:48 2:02 2:09 2:26
7th & ChannelKatella &Los AlamitosKatella & BeachKatella & BrookhurstKatella & HarborAnaheim Regional Transportation IntermodalCenter (ARTIC)Katella & GlassellVillage At Orange Zone 2 1:26 1:39 1:57 2:06 2:18 2:32 2:39 2:56
1:56 2:09 2:27 2:36 2:48 3:02 3:09 3:26
2:11 2:24 2:42 2:51 3:03 3:17 3:24 3:41
2:26 2:39 2:57 3:06 3:18 3:32 3:39 3:56
2:41 2:54 3:12 3:21 3:33 3:47 3:54 4:11
2:56 3:09 3:27 3:36 3:48 4:02 4:09 4:26
3:11 3:24 3:42 3:51 4:03 4:17 4:24 4:41
3:26 3:39 3:57 4:06 4:18 4:32 4:39 4:56
3:41 3:54 4:12 4:21 4:33 4:47 4:54 5:11
3:55 4:08 4:26 4:35 4:48 5:02 5:09 5:26
4:10 4:23 4:41 4:50 5:03 5:17 5:24 5:41
4:25 4:38 4:56 5:05 5:18 5:32 5:39 5:56
4:43 4:56 5:13 5:21 5:34 5:47 5:53 6:09
4:58 5:11 5:28 5:36 5:49 6:02 6:08 6:24
5:13 5:26 5:43 5:51 6:04 6:17 6:23 6:39
5:28 5:41 5:58 6:06 6:19 6:32 6:38 6:54
5:43 5:56 6:13 6:21 6:34 6:47 6:53 7:09
5:58 6:11 6:28 6:36 6:49 7:02 7:08 7:24
6:28 6:41 6:58 7:06 7:19 7:32 7:38 7:54
6:58 7:11 7:28 7:36 7:49 8:02 8:08 8:24
7:28 7:41 7:58 8:06 8:19 8:32 8:38 8:54
8:09 8:20 8:34 8:41 8:52 9:04 9:09 9:25
8:41 8:52 9:06 9:13 9:24 9:36 9:41 9:57
9:46 9:57 10:11 10:18 10:29 10:41 10:46 11:02
10:51 11:01 11:12 11:17 11:26 11:37 11:42 11:55
11:51 12:01 12:12 12:17 12:26 12:37 12:42 12:55
12:50 1:00 1:11 1:16 1:25 1:36 1:41 1:54
2004
Effective November 9, 2025 | Orange County Transportation Authority Monday-Friday
WESTBOUND To: Long Beach (cont.)
Monday-Friday
WESTBOUND To: Long Beach Village At Orange Zone 2 Katella & Glassell Anaheim Regional Transportation Intermodal Center (ARTIC) Katella & Harbor Katella & BrookhurstKatella & BeachKatella &Los Alamitos7th & Channel 3:52 3:58 4:05 4:13 4:21 4:26 4:39 4:59
4:17 4:23 4:30 4:38 4:46 4:51 5:04 5:24
4:38 4:44 4:53 5:02 5:11 5:18 5:32 5:54
4:59 5:05 5:14 5:23 5:32 5:39 5:53 6:15
5:18 5:24 5:33 5:42 5:51 5:58 6:12 6:34
5:34 5:40 5:49 5:58 6:07 6:14 6:28 6:50
5:43 5:51 6:00 6:13 6:24 6:31 6:48 7:13
5:58 6:06 6:15 6:28 6:39 6:46 7:03 7:28
6:13 6:21 6:30 6:43 6:54 7:01 7:18 7:43
6:28 6:36 6:45 6:58 7:09 7:16 7:33 7:58
6:43 6:51 7:00 7:13 7:24 7:31 7:48 8:13
6:58 7:06 7:15 7:28 7:39 7:46 8:03 8:28
7:13 7:21 7:30 7:43 7:54 8:01 8:18 8:43
7:28 7:36 7:45 7:58 8:09 8:16 8:33 8:58
7:43 7:51 8:00 8:13 8:24 8:31 8:48 9:13
7:58 8:06 8:15 8:28 8:39 8:46 9:03 9:28
8:13 8:21 8:31 8:43 8:55 9:02 9:19 9:44
8:28 8:36 8:46 8:58 9:10 9:17 9:34 9:59
8:43 8:51 9:01 9:13 9:25 9:32 9:49 10:14
8:58 9:06 9:16 9:28 9:40 9:47 10:04 10:29
9:15 9:23 9:33 9:45 9:57 10:04 10:21 10:46
9:43 9:51 10:01 10:13 10:25 10:32 10:49 11:14
10:09 10:18 10:29 10:43 10:55 11:03 11:21 11:47
10:39 10:48 10:59 11:13 11:25 11:33 11:51 12:17
11:09 11:18 11:29 11:43 11:55 12:03 12:21 12:47
11:39 11:48 11:59 12:13 12:25 12:33 12:51 1:17
12:09 12:18 12:29 12:43 12:55 1:03 1:21 1:47
12:39 12:48 12:59 1:13 1:25 1:33 1:51 2:17
Village At Orange Zone 2Katella & GlassellAnaheim Regional Transportation IntermodalCenter (ARTIC)Katella & HarborKatella & BrookhurstKatella & BeachKatella &Los Alamitos7th & Channel 1:09 1:18 1:29 1:43 1:55 2:03 2:21 2:47
1:38 1:47 1:58 2:11 2:23 2:31 2:49 3:15
1:53 2:02 2:13 2:26 2:38 2:46 3:04 3:30
2:08 2:17 2:28 2:41 2:53 3:01 3:19 3:45
2:23 2:32 2:43 2:56 3:08 3:16 3:34 4:00
2:38 2:47 2:58 3:11 3:23 3:31 3:49 4:15
2:53 3:02 3:13 3:26 3:38 3:46 4:04 4:30
3:08 3:17 3:28 3:41 3:53 4:01 4:19 4:45
3:23 3:32 3:43 3:56 4:08 4:16 4:34 5:00
3:38 3:47 3:58 4:11 4:23 4:31 4:49 5:15
3:53 4:02 4:13 4:26 4:38 4:46 5:04 5:30
4:08 4:17 4:28 4:41 4:53 5:01 5:19 5:45
4:21 4:31 4:42 4:56 5:08 5:15 5:32 5:57
4:36 4:46 4:57 5:11 5:23 5:30 5:47 6:12
4:51 5:01 5:12 5:26 5:38 5:45 6:02 6:27
5:06 5:16 5:27 5:41 5:53 6:00 6:17 6:42
5:21 5:31 5:42 5:56 6:08 6:15 6:32 6:57
5:36 5:46 5:57 6:11 6:23 6:30 6:47 7:12
5:51 6:01 6:12 6:26 6:38 6:45 7:02 7:27
6:06 6:16 6:27 6:41 6:53 7:00 7:17 7:42
6:37 6:47 6:58 7:12 7:24 7:31 7:48 8:13
7:13 7:21 7:30 7:43 7:53 8:00 8:16 8:38
7:43 7:51 8:00 8:13 8:23 8:30 8:46 9:08
8:07 8:15 8:24 8:37 8:47 8:54 9:10 9:32
9:10 9:18 9:27 9:40 9:50 9:57 10:13 10:35
10:10 10:18 10:27 10:40 10:50 10:57 11:13 11:35
11:18 11:24 11:32 11:43 11:53 11:58 12:09 12:29
12:18 12:24 12:32 12:43 12:53 12:58 1:09 1:29

Page 72 ends

50 Long Beach to Orange
via Katella Ave
2005
Build an ebusbook at ocbus.com/ebusbook | Effective November 9, 2025 Page 73 7th & Channel Katella & Los Alamitos Katella & Beach Katella & Brookhurst Katella & Harbor Anaheim Regional Transportation Intermodal Center (ARTIC) Katella & Glassell Village At Orange Zone 2 4:00 4:09 4:20 4:25 4:33 4:42 4:48 4:59
4:44 4:53 5:04 5:09 5:17 5:26 5:32 5:43
5:16 5:26 5:39 5:47 5:57 6:08 6:14 6:27
5:56 6:06 6:19 6:27 6:37 6:48 6:54 7:07
6:36 6:46 6:59 7:07 7:17 7:28 7:34 7:47
7:09 7:21 7:35 7:43 7:57 8:10 8:16 8:30
7:49 8:01 8:15 8:23 8:37 8:50 8:56 9:10
8:29 8:41 8:55 9:03 9:17 9:30 9:36 9:50
9:09 9:21 9:35 9:43 9:57 10:10 10:16 10:30
9:46 9:58 10:15 10:23 10:37 10:51 10:58 11:14
10:26 10:38 10:55 11:03 11:17 11:31 11:38 11:54
11:06 11:18 11:35 11:43 11:57 12:11 12:18 12:34
11:45 11:57 12:14 12:23 12:37 12:51 12:58 1:16
12:25 12:37 12:54 1:03 1:17 1:31 1:38 1:56
1:05 1:17 1:34 1:43 1:57 2:11 2:18 2:36
1:45 1:57 2:14 2:23 2:37 2:51 2:58 3:16
2:25 2:37 2:54 3:03 3:17 3:31 3:38 3:56
3:05 3:17 3:34 3:43 3:57 4:11 4:18 4:36
3:45 3:57 4:14 4:23 4:37 4:51 4:58 5:16
4:26 4:38 4:55 5:04 5:17 5:32 5:38 5:54
5:09 5:21 5:37 5:45 5:57 6:11 6:17 6:33
5:49 6:01 6:17 6:25 6:37 6:51 6:57 7:13
6:29 6:41 6:57 7:05 7:17 7:31 7:37 7:53
7:09 7:21 7:37 7:45 7:57 8:11 8:17 8:33
7:49 8:01 8:17 8:25 8:37 8:51 8:57 9:13
8:37 8:49 9:03 9:10 9:21 9:34 9:39 9:53
9:37 9:49 10:03 10:10 10:21 10:34 10:39 10:53
10:37 10:49 11:03 11:10 11:21 11:34 11:39 11:53
11:45 11:55 12:06 12:12 12:21 12:33 12:38 12:50
12:45 12:55 1:06 1:12 1:21 1:33 1:38 1:50
Saturday, Sunday & Holiday
EASTBOUND To: Orange
Operates Saturday Only.

Unicamente los sabados.

Village At Orange Zone 2Katella & GlassellAnaheim Regional Transportation IntermodalCenter (ARTIC)Katella & HarborKatella & BrookhurstKatella & BeachKatella &Los Alamitos7th & Channel 4:40 4:47 4:58 5:06 5:15 5:20 5:32 5:52
5:20 5:27 5:38 5:46 5:55 6:00 6:12 6:32
5:55 6:04 6:15 6:26 6:37 6:43 6:58 7:22
6:35 6:44 6:55 7:06 7:17 7:23 7:38 8:02
7:15 7:24 7:35 7:46 7:57 8:03 8:18 8:42
7:55 8:04 8:15 8:26 8:37 8:43 8:58 9:22
8:32 8:42 8:54 9:06 9:18 9:25 9:42 10:08
9:12 9:22 9:34 9:46 9:58 10:05 10:22 10:48
9:52 10:02 10:14 10:26 10:38 10:45 11:02 11:28
10:32 10:42 10:54 11:06 11:18 11:25 11:42 12:08
11:10 11:22 11:34 11:46 11:58 12:05 12:22 12:49
11:50 12:02 12:14 12:26 12:38 12:45 1:02 1:29
12:30 12:42 12:54 1:06 1:18 1:25 1:42 2:09
1:09 1:20 1:32 1:46 1:59 2:06 2:23 2:48
1:49 2:00 2:12 2:26 2:39 2:46 3:03 3:28
2:29 2:40 2:52 3:06 3:19 3:26 3:43 4:08
3:09 3:20 3:32 3:46 3:59 4:06 4:23 4:48
3:49 4:00 4:12 4:26 4:39 4:46 5:03 5:28
4:29 4:40 4:52 5:06 5:19 5:26 5:43 6:08
5:09 5:20 5:32 5:46 5:59 6:06 6:23 6:48
5:49 6:00 6:12 6:26 6:39 6:46 7:03 7:28
6:29 6:38 6:51 7:06 7:19 7:25 7:40 8:02
7:09 7:18 7:31 7:46 7:59 8:05 8:20 8:42
7:49 7:58 8:11 8:26 8:39 8:45 9:00 9:22
8:29 8:38 8:51 9:06 9:19 9:25 9:40 10:02
9:09 9:18 9:31 9:46 9:59 10:05 10:20 10:42
10:19 10:26 10:35 10:46 10:55 11:01 11:14 11:33
11:19 11:26 11:35 11:46 11:55 12:01 12:14 12:33
12:19 12:26 12:35 12:46 12:55 1:01 1:14 1:33
Saturday, Sunday & Holiday
WESTBOUND To: Long Beach
50 Long Beach to Orange
via Katella Ave
2006
2375 North Tustin Street Project VMT Analysis
APPENDIX C – OCTAM INPUTS AND OUTPUTS
2007
Model Run SED 2375 North Tustin Street Project, City of Orange TAZ 573
Dwelling Units to add to TAZ 71
1 SCAG Connect SoCal SCS
2008
No Project 2019
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 109 109 66 27 98605 582 697 24 0 0
573 1126 1126 833 337 95733 537 402 82 0 0
Plus Project 2019
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1235 1235 899 364 98605 1119 1099 106 0 0
573 237 237 175 71 95733 0 0 0 0 0
Plus Project - No project
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1126 1126 833 337 0 537 402 82 0 0
573 -889 -889 -658 -266 0 -537 -402 -82 0 0
No Project 2050
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 99 99 61 27 98605 634 715 22 0 0
573 1109 1109 820 387 95733 474 405 76 0 0
Plus Project 2050
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1208 1208 881 414 98605 1108 1120 98 0 0
573 237 237 175 71 95733 0 0 0 0 0
Plus Project - No project
ZONE TOT_POP HH_POP EMP_POP TOT_HH MDN_INC RET_EMP SVC_EMP BAS_EMP SCH_ENR UNIV_ENR 572 1109 1109 820 387 0 474 405 76 0 0
573 -872 -872 -645 -316 0 -474 -405 -76 0 0
2009
Zone ID Time Perio Home-Based V Home-Based Other VMT (PA Total VMT (OD Home-Based V Home-Based W Other VMT (ODTotal Intrazona TotalVehicle Total Intrazon Average Tr Population Employmen Enrollment Service Popul HBVMT_pe HBWVMT_ TOTVMT_per_SerPop (OD) HBVMT_pe HBWVMT_per_Emp (OD) 573 Daily 4653.09 64.6585 512.605 7659.39 6814.04 94.6867 750.665 0.110013 719.186 0.143188 10.6521 237 0 0 237 19.6333 0 32.3181 28.7512 0 2010
Zone ID Time Perio Home-Base Home-Base Other VMT Total VMT Home-Base Home-Base Other VMT Total Intra Total Vehic Total Intraz Average Tr Population Employme EnrollmentService PopHBVMT_pe HBWVMT_ TOTVMT_p HBVMT_pe HBWVMT_per_Emp (OD) 573 Daily 4835.2 60.7212 508.169 8145.5 7288.02 91.5242 765.956 0.101875 730.614 0.132596 11.1507 237 0 0 237 20.4017 0 34.3692 30.7511 0 2011
2375 North Tustin Street Project VMT Analysis
APPENDIX D – VMT REDUCTION CALCULATION AND SUPPORTING

DOCUMENTS
2012
T-1. Increase Residential Density
GHG Reduction formula GHG Reduction formula
A = B - C * D -15.4% = 22.57 - 13.27 * -0.22
C 13.27
User Inputs Value Unit Source
B Residential density of project development 22.57 DU/acre User input Constants, Assumptions, and Available Defaults
C Residential density of a typical development in TAZ 573 13.27 DU/acre User input D Elasticity of VMT with respect to residential density -0.22 Unitless Stevens 2016 Output
A Percent reduction in GHG emissions from project VMT in study area -15.4% % Calculated 2013
TRANSPORTATION | 70
T-1. Increase Residential Density
GHG Mitigation Potential
Up to 30.0% of GHG
emissions from project VMT
in the study area
Co-Benefits (icon key on pg. 34)
Climate Resilience
Increased density can put people closer to
resources they may need to access during
an extreme weather event. Increased density
can also shorten commutes, decreasing the
amount of time people are on the road and
exposed to hazards such as extreme heat
or flooding.

Health and Equity Considerations
Neighborhoods should include different
types of housing to support a variety of
household sizes, age ranges, and incomes.

Measure Description
This measure accounts for the VMT reduction achieved by a project that is designed with a higher density of dwelling units (du) compared to the average residential density in the U.S. Increased densities affect the distance people travel and provide greater options for the mode of travel they choose. Increasing residential density results in shorter and fewer trips by single-occupancy vehicles and thus a reduction in GHG emissions. This measure is best quantified when applied to larger developments and developments where the density is somewhat similar to the surrounding area due to the underlying research being founded in data from the
neighborhood level.

Subsector
Land Use
Locational Context
Urban, suburban
Scale of Application
Project/Site
Implementation Requirements
This measure is most accurately quantified when applied to larger developments and/or developments where the density is
somewhat similar to the surrounding neighborhood.

Cost Considerations
Depending on the location, increasing residential density may increase housing and development costs. However, the costs of providing public services, such as health care, education, policing, and transit, are generally lower in more dense areas where things are closer together. Infrastructure that provides drinking water and electricity also operates more efficiently when the service and transmission area is reduced. Local governments may provide approval streamlining benefits or financial incentives for infill and high-density residential projects.

Expanded Mitigation Options
When paired with Measure T-2, Increase Job Density, the cumulative densification from these measures can result in a highly walkable and bikeable area, yielding increased co-benefits in VMT reductions, improved public health, and social equity. 30%
2014

T-1. Increase Residential Density TRANSPORTATION | 71
GHG Reduction Formula
A =
B − C
C
× D
GHG Calculation Variables
ID Variable Value Unit Source
Output
A Percent reduction in GHG emissions from project
VMT in study area
0–30.0 % calculated
User Inputs
B Residential density of project development [ ] du/acre user input Constants, Assumptions, and Available Defaults
C Residential density of typical development 9.1 du/acre Ewing et al. 2007
D Elasticity of VMT with respect to residential density -0.22 unitless Stevens 2016
Further explanation of key variables:
▪ (C) – The residential density of typical development is based on the blended average density of residential development in the U.S. forecasted for 2025. This estimate includes apartments, condominiums, and townhouses, as well as detached single-family housing on both small and large lots. An acre in this context is defined as an acre of developed land, not including streets, school sites, parks, and other undevelopable land. If reductions are being calculated from a specific baseline derived from a travel demand forecasting model, the residential density of the relevant transportation analysis zone should be used instead of the value for a typical development.
▪ (D) – A meta-regression analysis of five studies that controlled for self-selection found that a 0.22 percent decrease in VMT occurs for every 1 percent increase in residential density (Stevens 2016).

GHG Calculation Caps or Maximums
Measure Maximum
(Amax) The percent reduction in GHG emissions (A) is capped at 30 percent. The purpose for the 30 percent cap is to limit the influence of any single built environmental factor (such as density). Projects that implement multiple land use strategies (e.g., density, design, diversity) will show more of a reduction than relying on improvements from a single built environment factor.
2015
T-1. Increase Residential Density TRANSPORTATION | 72
Subsector Maximum
( ∑ AmaxT-1 through T-4 ≤65%) This measure is in the Land Use subsector. This subcategory includes Measures T-1 through T-4. The VMT reduction from the combined implementation of all measures within this subsector is capped at 65 percent.

Example GHG Reduction Quantification
The user reduces VMT by increasing the residential density of the project study area. In this example, the project’s residential density would be 15 du per acre (B), which would reduce GHG emissions from project VMT by 14.2 percent.

Quantified Co-Benefits
Improved Local Air Quality
The percent reduction in GHG emissions (A) would be the same as the percent reduction in NOX, CO, NO2, SO2, and PM. Reductions in ROG emissions can be calculated by multiplying the percent reduction in GHG emissions (A) by an adjustment factor of 87 percent. See Adjusting VMT Reductions to Emission Reductions above for further discussion.

Energy and Fuel Savings
The percent reduction in vehicle fuel consumption would be the same as the percent reduction in GHG emissions (A).

VMT Reductions
The percent reduction in VMT would be the same as the percent reduction in GHG emissions (A).

Sources
▪ Ewing, R., K. Bartholomew, S. Winkelman, J. Walters, and D. Chen. 2007. Growing Cooler: The Evidence on Urban Development and Climate Change. October. Available:
https://www.nrdc.org/sites/default/files/cit_07092401a.pdf. Accessed: January 2021. ▪ Stevens, M. 2016. Does Compact Development Make People Drive Less? Journal of the American Planning Association 83:1(7–18), DOI: 10.1080/01944363.2016.1240044. November. Available:
https://www.researchgate.net/publication/309890412_Does_Compact_Development_Make_People_ Drive_Less. Accessed: January 2021.

A =
15 du
ac
− 9.1 du
ac

9.1 du
ac
× -0.22 = -14.2%
2016
Appendix L: Mitigation Monitoring and Reporting Program 2017

CITY OF ORANGE NORTH TUSTIN STREET RESIDENTIAL PROJECT

INITIAL STUDY/MITIGATED NEGATIVE DECLARATION
NO. ENV25-0001
Mitigation Monitoring and Reporting Plan
The California Environmental Quality Act (CEQA) requires that when a public agency completes an environmental document which includes measures to mitigate or avoid significant environmental effects, the public agency must adopt a reporting or monitoring plan. This requirement ensures that environmental impacts found to be potentially significant will be mitigated. The reporting or monitoring plan must be designed to ensure compliance during project implementation (Public Resources Code Section 21081.6).

In compliance with Public Resources Code Section 21081.6, the attached Mitigation Monitoring and Reporting Checklist, has been prepared for the North Tustin Street Residential Project. The table identifies Project Design Features (PDFs); Plans, Programs, and Policies (PPPs); and Mitigation Measures (MMs) required by the City to mitigate or avoid significant adverse impacts associated with the implementation of the Project. This Mitigation Monitoring and Reporting Checklist is intended to provide verification that all applicable mitigation measures relative to significant environmental impacts are monitored and reported. Monitoring will include: 1) verification that each mitigation measure has been implemented; 2) recordation of the actions taken to implement each mitigation measure; and 3) retention of records in the City’s North Tustin Street Residential project file.

This Mitigation Monitoring and Reporting Program (MMRP) delineates responsibilities for monitoring the Project but also allows the City flexibility and discretion in determining how best to monitor implementation. Monitoring procedures will vary according to the type of mitigation measure. Adequate monitoring consists of demonstrating that monitoring procedures took place and that mitigation measures were implemented. This includes the review of all monitoring reports, enforcement actions, and document disposition, unless otherwise noted in the Mitigation Monitoring and Reporting Checklist. If an adopted mitigation measure is not being properly implemented, the designated monitoring personnel shall require corrective actions to ensure adequate implementation.

Reporting consists of establishing a record that a mitigation measure is being implemented, and generally involves the following steps:
• The City distributes reporting forms to the appropriate entities for verification of compliance.
• Departments/agencies with reporting responsibilities will review the Mitigated Negative Declaration, which provides general background information on the reasons for including specified mitigation measures.
• Periodic meetings may be held during Project implementation to report on compliance of mitigation measures.
• Responsible parties provide the City with verification that monitoring has been conducted and ensure, as applicable, that mitigation measures have been implemented. Monitoring 2018
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 2 compliance may be documented through existing review and approval programs such as field inspection reports and plan review.
• The City prepares a reporting form periodically during the construction phase and an annual report summarizing all project mitigation monitoring efforts. • Appropriate mitigation measures will be included in construction documents and/or conditions of permits/approvals.

Minor changes to the MMRP, if required, would be made in accordance with CEQA and would be permitted after review and approval by the City. Such changes could include reassignment of monitoring and reporting responsibilities, plan redesign to make any appropriate improvements, and/or modification, substitution or deletion of mitigation measures subject to conditions described in CEQA Guidelines Section 15162. No change will be permitted unless the MMRP continues to satisfy the requirements of Public Resources Code Section 21081. 2019
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 3 Mitigation Monitoring and Reporting Checklist
No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
Aesthetics
PPP
AES-1
Exterior Lighting. Exterior lighting on the Project
site shall conform to the regulations within Orange
Municipal Code Section 17.12.030. Lighting on any
premises shall be directed, controlled, screened or
shaded in such a manner as not to shine directly on
surrounding premises. Lighting on any residential
property shall be controlled so as to prevent glare or
direct illumination of any public sidewalk or
thoroughfares.

Prior to Building
Permits.

City of Orange
Building & Safety
Prior to Building
Permits.

City of Orange
Building & Safety
Air Quality
PPP
AQ-1
Rule 402. The Project is required to comply with the
provisions of South Coast Air Quality Management
District (SCAQMD) Rule 402. The Project shall not
discharge from any source whatsoever such quantities
of air contaminants or other material which cause
injury, detriment, nuisance, or annoyance to any
considerable number of persons or to the public, or
which endanger the comfort, repose, health or safety
of any such persons or the public, or which cause, or
have a natural tendency to cause, injury or damage to
business or property.

Prior to
Demolition,
Grading and
Building Permits
City of Orange
Building & Safety
During
construction
City of Orange
Building & Safety
2020
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 4 No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
PPP
AQ-2
Rule 403. The Project is required to comply with the
provisions of South Coast Air Quality Management
District (SCAQMD) Rule 403, which includes the
following:
• All clearing, grading, earth-moving, or
excavation activities shall cease when winds
exceed 25 mph per SCAQMD guidelines in
order to limit fugitive dust emissions.
• The contractor shall ensure that all disturbed
unpaved roads and disturbed areas within the
Project are watered, with complete coverage of
disturbed areas, at least 3 times daily during dry
weather; preferably in the mid-morning,
afternoon, and after work is done for the day.
• The contractor shall ensure that traffic speeds on
unpaved roads and Project site areas are reduced
to 15 miles per hour or less.

Prior to
Demolition,
Grading and
Building Permits
City of Orange
Building & Safety
During
Construction
City of Orange
Building & Safety
PPP
AQ-3
Rule 1113. The Project is required to comply with the
provisions of South Coast Air Quality Management
District Rule (SCAQMD) Rule 1113. Only “LowVolatile Organic Compounds” paints (no more than 50 gram/liter of VOC) and/or High Pressure Low Volume
(HPLV) applications shall be used.

Prior to Building
Permits
City of Orange
Building & Safety
During
Construction
City of Orange
Building & Safety
2021
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 5 No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
Biological Resources
MM
BIO-1
Pre‐construction Nesting Bird Survey. Construction
plans and Project specifications shall state that if
construction or vegetation removal activities are
scheduled to occur during the bird breeding season
(February 1 through August 31), a pre‐construction
nesting bird survey shall be conducted by a qualified
biologist to ensure that active bird nests will not be
disturbed or destroyed. The survey shall be completed
no more than three days prior to initial ground
disturbance. The nesting bird survey shall include the
Project area and adjacent areas where Project activities have the potential to affect active nests, either directly or indirectly due to construction activity or noise. If an active nest is identified, a qualified biologist shall
establish an appropriate disturbance limit buffer
around the nest using flagging or staking. Construction activities shall not occur within any disturbance limit buffer zones until the nest is deemed inactive by the
qualified biologist.

Prior to
Demolition and
Grading Permits
City of Orange
Planning
Prior to
Demolition and
Grading Permits
Qualified
Biologist
Cultural Resources
PPP
CUL-1
Human Remains. In the event that human remains are
encountered on the Project site, work within 50 feet of the discovery shall cease and the County Coroner shall
be notified immediately consistent with the
requirements of CEQA Guidelines Section
Prior to Grading
Permits.

During
Construction
2022
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 6 No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
15064.5(e). State Health and Safety Code Section
7050.5 states that no further disturbance shall occur
until the County Coroner has made a determination of
origin and disposition pursuant to Public Resources
Code (PRC) Section 5097.98. Prior to the issuance of
grading permits, the City Community and Planning,
Building, and Code Enforcement Department
Director, or designee, shall verify that all grading
plans specify the requirements of CEQA Guidelines
Section 15064.5(e), Health and Safety Code Section
7050.5, and PRC Section 5097.98, as stated above..

City of Orange
Planning
City of Orange
Planning
Energy
PPP E1 Title 24 CalGreen Compliance: T The Project is
required to comply with the Title 24 standards that are adopted by reference in Chapter 15.54 of the City of
Orange Municipal Code and the CalGreen Building
Code as included in the Orange Municipal Code
Section 15.17.010 to ensure efficient use of energy.

Title 24 and CalGreen specifications are required to be incorporated into building plans as a condition of
building permit approval.

Prior to Building
Permits.

City of Orange
Building & Safety
Before
construction.

City of Orange
Building & Safety
Geology and Soils
PPP
GEO-1
California Building Code. Prior to issuance of any
construction permits, the project is required to
demonstrate compliance with the California Building
Code as included in the Orange Municipal Code
Prior to Building
Permits
Before
construction.
2023
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 7 No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
Chapter 15.04 to preclude significant adverse effects
associated with seismic hazards, including expansive
and corrosive soils. California Building Code related
and geologist and/or civil engineer specifications for
the project are required to be incorporated into grading plans and specifications as a condition of construction permit approval.

City of Orange
Building & Safety
City of Orange
Building & Safety
Greenhouse Gas Emissions
PPP E1 Title 24 CalGreen Compliance. As listed previously in Energy.

Prior to Building
Permits
City of Orange
Building & Safety
Before
Construction
City of Orange
Building & Safety
Hydrology and Water Quality
PPP
WQ-1
NPDES/SWPPP. Prior to issuance of any grading or
demolition permits, the applicant shall provide the
City evidence of compliance with the NPDES
(National Pollutant Discharge Elimination System)
requirement to obtain a construction permit from the
State Water Resource Control Board (SWRCB). The
permit requirement applies to grading and
construction sites of one acre or larger. The Project
applicant/proponent shall comply by submitting a
Notice of Intent (NOI) and by developing and
implementing a Stormwater Pollution Prevention Plan
Prior to Grading
and Demolition
Permits
City of Orange
Public Works
Prior to
Construction
City of Orange
Public Works
2024
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 8 No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
(SWPPP) and a monitoring program and reporting
plan for the construction site.

PPP
WQ-2
WQMP. Prior to the approval of the Grading Plan and
issuance of Grading Permits a completed Water
Quality Management Plan (WQMP) shall be
submitted to and approved by the City . The WQMP
shall identify all Post-Construction, Site Design.

Source Control, and Treatment Control Best
Management Practices (BMPs) that will be
incorporated into the development project in order to
minimize the adverse effects on receiving waters.

Prior to Grading
and Building
Permits
City of Orange
Building and
Public Works
Prior to
Construction
City of Orange
Building and
Public Works
Noise
PDF-1 Interior Noise. Project building plans, specifications, and permits shall detail that the third floor of the
residence in the northeastern most portion of the site
(Lot 54) will be developed with upgraded windows
that have a minimum Sound Transmission Class
(STC) rating of 31.

Prior to Building
and Occupancy
Permits
City of Orange
Building and
Public Works
Site inspection of
Lot 54 prior to
Occupancy
Permits
City of Orange
Building and
Public Works
MM
NOI-1
Vibration. The City of Orange (City) Director of
Community Development, or designee, shall verify
prior to issuance of demolition or grading permits, that the construction plans require that the construction
contractor restrict the use of heavy construction
equipment (i.e., greater than 80,000 pounds), vibratory Prior to Grading
and Demolition
Permits
During
Construction
City of Orange
Building & Safety
2025
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 9 No. Project Design Feature / Plan, Program, Policy /
Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
rollers, large loaded trucks, and large dozers within 20 feet of any off-site receiver location. Instead, smaller, rubber-tired bulldozers (less than 80,000 pounds) shall be used within this area during Project construction to reduce vibration levels.

City of Orange
Building & Safety
Tribal Cultural Resources
MM
TCR-1
Native American Monitoring.

A. The Project plans, specifications, and grading
permits shall state that the Project applicant shall
retain a Native American Monitor. The monitor
shall be retained prior to the commencement of any
“ground-disturbing activity” for the subject Project
at all Project locations (i.e., both on-site and any
off-site locations that are included in the project
description and/or required in connection with the
Project, such as public improvement work).
“Ground-disturbing activity” shall include, but is
not limited to, demolition, pavement removal,
potholing, auguring, grubbing, tree removal,
boring, grading, excavation, drilling, and
trenching.

B. A copy of the executed monitoring agreement shall
be submitted to the City prior to the earlier of the
commencement of any ground-disturbing activity,
or the issuance of any permit necessary to
commence a ground-disturbing activity.

Prior to Ground
Disturbing
Activities
City of Orange
Planning
During
Construction
Native American
Monitor
2026
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 10 No. Project Design Feature / Plan, Program, Policy / Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
C. The monitor shall complete daily monitoring logs
that will provide descriptions of the relevant
ground-disturbing activities, the type of
construction activities performed, locations of
ground-disturbing activities, soil types, culturalrelated materials, and any other facts, conditions, materials, or discoveries of significance to the
Tribe. Monitor logs shall identify and describe any
discovered TCRs, including but not limited to,
Native American cultural and historical artifacts,
remains, places of significance, etc., (collectively,
tribal cultural resources, or “TCR”), as well as any
discovered Native American (ancestral) human
remains and burial goods. Copies of monitor logs
shall be provided to the Project applicant/lead
agency upon written request to the Tribe.

D. On-site tribal monitoring shall conclude upon the
latter of the following (1) written confirmation to
the monitoring Tribe from a designated point of
contact for the Project applicant/lead agency that
all ground-disturbing activities and phases that
may involve ground-disturbing activities on the
Project site or in connection with the Project are
complete; or (2) a determination and written
notification by the monitoring Tribe to the Project
applicant/lead agency that no future, planned
construction activity and/or
2027
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 11 No. Project Design Feature / Plan, Program, Policy / Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
development/construction phase at the Project site
possesses the potential to impact TCRs.

MM
TCR-2
Unanticipated Discovery of Tribal Cultural
Resource Objects.

A. Upon discovery of any TCRs, the monitoring tribe
notify the City and Project Applicant and all
construction activities in the immediate vicinity of
the discovery shall cease (i.e., not less than the
surrounding 50 feet) and shall not resume until the
discovered TCR has been fully assessed by the
tribal monitor and/or tribal archaeologist. The
monitoring tribe shall recover and retain all
discovered TCRs in the form and/or manner the
monitoring tribe deem appropriate.

During Ground
Disturbing
Activities
City of Orange
Planning
During
Construction
Native American
Monitor
MM
TCR-3
Unanticipated Discovery of Human Remains and
Associated Funerary or Ceremonial Objects.

A. MM TCR-3: Unanticipated Discovery of Human
Remains and Associated Funerary or Ceremonial
Objects.

B. Native American human remains are defined in
PRC 5097.98 (d)(1) as an inhumation or
cremation, and in any state of decomposition or
skeletal completeness. Funerary objects, called
associated grave goods in Public Resources Code
Section 5097.98, are also to be treated according to
this statute.

During Ground
Disturbing
Activities
City of Orange
Planning
During
Construction
Native American
Monitor
2028
City of Orange North Tustin Street Residential Project
Mitigation Monitoring and Reporting Program MND NO. ENV25-0001 12 No. Project Design Feature / Plan, Program, Policy / Mitigation Measure
Time Frame and
Responsible
Party for
Implementation
Time Frame and
Responsible
Party for
Monitoring
Verification of Compliance
Initials Date Remarks
C. If Native American human remains and/or grave
goods are discovered or recognized on the Project
site, then Public Resource Code 5097.9 as well as
Health and Safety Code Section 7050.5 shall be
followed.

D. Human remains and grave/burial goods shall be
treated alike per California Public Resources Code
section 5097.98(d)(1) and (2).

E. Preservation in place (i.e., avoidance) is the
preferred manner of treatment for discovered
human remains and/or burial goods.

F. Any discovery of human remains/burial goods
shall be kept confidential to prevent further
disturbance.

PPP
CUL-1
Human Remains. California Health and Safety Code
Section 7050.5. Listed previously in Section 5,
Cultural Resources.

Prior to Grading
Permits
City of Orange
Planning
During
Construction
City of Orange
Planning
2029
Attachment 9
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
Agenda Item
Planning Commission
Item #: 3.1. 4/6/2026 File #: 26-0167
TO: Chair and Members of the Planning Commission
THRU: Hayden Beckman, Planning Manager
FROM: Monique Schwartz, Principal Planner

1. SUBJECT
Public Hearing to consider a proposal to redevelop a commercial property with 71 small lot singlefamily homes at 2375 N. Tustin Street. An Initial Study/Mitigated Negative Declaration was prepared in conformance with CEQA (GPA25-0003, ZC25-0002, TTM25-0001, MJSP25-0002, ADR25-0018, and ENV25-0001).

2. SUMMARY
The applicant proposes redeveloping an existing 4.23-acre vacant commercial site (former Best Buy) with 71, three-story single-family small lot homes, open space recreation area, guest parking, and related site improvements. To allow for the development at this location, the proposal includes a request to amend the General Plan land use designation from General Commercial Max. 1.0 FAR (GC) to Medium Density Residential, 15-24 dwelling units per acre (MDR) and a request to amend the zoning from Limited Business Tustin Redevelopment Project Area (C-TR) to Residential Multiple Family (R-3) with application of the Small Lot Subdivision Development Standards.

3. RECOMMENDED ACTION

1. Conduct and close the Public Hearing.

2. Adopt Planning Commission Resolution No. PC 08-26 recommending City Council approval of General Plan Amendment No. GPA25-0003, a request to change the General Plan designation from General Commercial to Medium Density Residential on a 4.23-acre site located at 2375 N. Tustin Street.

3. Adopt Planning Commission Resolution No. PC 09-26 recommending the City Council approval of Zone Change No. 25-0002 and adoption of an Ordinance to change the zoning designation from Limited Business Tustin Redevelopment Project Area to Residential Multiple Family to establish consistency between the Medium Density General Plan Land Use designation and zoning classification in accordance with state law on a 4.23-acre site located at 2375 N. Tustin Street.

4. Adopt Planning Commission Resolution No. PC 10-26 recommending City Council approval of Tentative Tract Map No. TTM25-0001, Major Site Plan Review No. MJSP25-0002, Administrative Design Review No. ADR25-0018, IS/MND No. ENV25-0001 and associated Mitigation Monitoring and Reporting Program for the redevelopment of a vacant commercial site with 71, three-story single-family small lot homes, open space recreation area, guest City of Orange Page 1 of 10 Printed on 4/2/2026
powered by Legistar™
Attachment 10
2066
Item #: 3.1. 4/6/2026 File #: 26-0167
parking, and related site improvements on a 4.23-acre site located at 2375 N. Tustin Street.

4. PROJECT BACKGROUND
Property Information
Applicant: Chad Brown, Melia Homes
Property Owner: BTPROP3 LLC
Property Location: 2375 N. Tustin Street
Existing General Plan Land Use Element: General Commercial, Max. 1.0 FAR (GC) Existing Zoning: Limited Business Tustin Redevelopment Project Area (C-TR) Old Towne: No
Specific Plan/PC: No
Site Size: 4.23-acres
Circulation: The project site is located on the east side of North Tustin Street, between East Heim and East Meats Avenues. The City’s Master Plan of Streets and Highways classifies North Tustin Street as a Major Arterial with an ultimate right -of-way width of 120 feet. The existing site is currently accessed by a signalized shared driveway along North Tustin Street.

There are existing bus stops located on the east and west sides of North Tustin Street in the vicinity of the project.

Existing Conditions: The site is currently developed with a vacant 45,676-square-foot commercial building (former Best Buy retail store), surface parking lot, mature trees and landscaping, perimeter walls, and site improvements. The commercial building and site improvements will be removed to accommodate the project.

Surrounding Land Uses and Zoning:

North: Single-story condominiums, zoned Residential Multiple Family Single Story Overlay (R-3(A)).

South: Single-story condominiums and mobile homes, zoned Residential Multiple Family Single Story Overlay (R-3(A)) and Mobile Home Residential (MH).

East: Unimproved parcel with a 93-foot-tall billboard sign, zoned Limited Business Tustin Redevelopment Project Area (C-TR). Further east is the State Route 55 Freeway.

City of Orange Page 2 of 10 Printed on 4/2/2026
powered by Legistar™2067
Item #: 3.1. 4/6/2026 File #: 26-0167
West: Commercial uses zoned C-TR. Further west is North Tustin Street and the Village at Orange mall, zoned C-TR.

Previous Applications/Entitlements:

On February 22, 1995, the Design Review Board approved DRB 3034 for modifications to the façade of an existing bowling center.

On March 9, 1995, the Zoning Administrator approved Variance No. 1989-95 to waive the Orange Municipal Code development standards for wall sign area and height.

On August 3, 1998, the Planning Commission denied appeal #443 and upheld the Staff Review Committee’s denial of Minor Site Plan Review No. 50-98 and Parcel Map 97-226 for a two-parcel subdivision.

On October 15, 2007, the Planning Commission approved Resolution No. PC 40-07 approving Mitigated Negative Declaration No. 1793-07, Major Site Plan Review No. 0526-07, Conditional Use Permit No. 2673-07, Design Review No. 4273-07, and Variance No. 2181-07 for a proposal to demolish a 30,000 square foot building formerly occupied by a bowling alley and a 7,250 square foot car wash to construct a 45,750 square foot retail building (Best Buy) and a 1,700 square foot drive through coffee dispensary (Starbucks).

On March 1, 2023, the Community Development Director approved Administrative Design Review No. 0213 for the exterior remodel of the existing retail store.

5. PROJECT DESCRIPTION
The project involves a request to demolish a vacant retail store (former Best Buy) and develop 71 three-story single-family small lot homes (58 paired and 13 detached), open space recreation area, guest parking, and related site improvements (See Attachment 8 Project Plans).

To allow for the development in this location, the applicant is proposing a General Plan Amendment to change the General Plan Land Use Element designation from General Commercial Max. 1.0 FAR (GC) to Medium Density Residential 15-24 dwelling units per acre (MDR), and a Zone Change from Limited Business Tustin Redevelopment Project Area (C-TR) to Residential Multiple Family (R-3) to accommodate a small lot subdivision in accordance with the City’s Small Lot Subdivision Ordinance (OMC Section 17.14.270). The proposed development will have a density of 16.76 dwelling units per acre. The proposal includes a Vesting Tentative Tract Map for the small lot subdivision including establishment of private and common use areas.

The Small Lot Subdivision Development Standards and Guidelines allow for the development of smaller fee simple, single-family residential lots in multi-family residential zones (R-3, R-4) and the Neighborhood Mixed Use (NMU-24) zone. The lots created under these standards are less than the typical minimum area of a traditional single-family lot, which allows for flexibility in lot configuration, City of Orange Page 3 of 10 Printed on 4/2/2026
powered by Legistar™2068
Item #: 3.1. 4/6/2026 File #: 26-0167
typical minimum area of a traditional single-family lot, which allows for flexibility in lot configuration, and reduces the amount of land required for new-single family residences. The development standards include regulations for lot frontage, setbacks, stories, height, private open space, and parking. These development standards allow for a space-efficient and economical alternative to traditional options for home ownership.

The project includes small lots ranging from 1,515 to 3,376 square feet. There are 36 units located within the interior cluster that have primary entries off landscaped paseos and walkways, and 35 units along the northern, southern, and western boundaries that have primary entries off the looped roadway and interior walkways.

The project provides five different floor plans with units ranging from 2,008 to 2,117 square feet (See Sheet SP - Site Plan of Attachment 8). In addition, each unit plan provides garage space dedicated for the storage of three trash carts for the collection of solid waste, recyclables, and organics and a minimum of 120 cubic feet of storage.

Floor
Plan
No. of
Units
Gross Area
(sq ft)
No. of
Stories
No. of
Bedrooms
No. of
Bathrooms
Garage (sq
ft)
Plan 1 10 2,008 3 + Roof
Deck
3 + den 2 full + 2 powder
rooms
472
Plan 2 16 2,014 3 3 + den 2 full + 2 powder
rooms
446
Plan 3A 1 2,026 3 4 3 full + 1 powder
room
477
Plan
3B/3C
13 2,026 3 + Roof
Deck
4 3 full + 1 powder
room
477
Plan 4 13 2,086 3 + Roof
Deck
3 + den 2 full + 2 powder
rooms
473
Plan
5A/5B
18 2,117 3 3 + den 2 full + 2 powder
rooms
446
Total 71
Architecture
The project site is located within an area containing a mix of commercial and residential uses with eclectic architectural styles. The project introduces a contemporary residential design that is intended to respond to the visual character of the area. All units feature three-stories. Units within the interior cluster incorporate roof decks with a maximum building height of 35 feet. No roof decks are proposed on units along the perimeter boundaries, adjacent to existing single-story condominiums and mobile homes to the north and south. The building orientations along the property boundaries consider the site’s characteristics and the City’s Small Lot Subdivision Guidelines (Attachment 11) in that the main entrances are oriented towards the private roadway and walkways to create a relationship between the buildings and pedestrians and to establish a strong tie to the internal street frontages. The main entrances of the units within the interior cluster are oriented towards the landscaped paseos or walkways. These paseos/walkways connect to the private roadways, open space recreation area, and public right-of-way.

Architectural elements of the proposed residences include a combination of flat, gable, and shed roof forms, parapets, arched and rectangular entries, recessed and simple door and window detailing, City of Orange Page 4 of 10 Printed on 4/2/2026
powered by Legistar™2069
Item #: 3.1. 4/6/2026 File #: 26-0167
forms, parapets, arched and rectangular entries, recessed and simple door and window detailing, porch elements, use of trim and siding, and alternating plane changes to add visual interest. The use of varied rooflines, articulated building elevations, and arches help soften the scale and rectangular massing of the buildings and are generally compatible with the architecture of the commercial buildings to the west. The proposed exterior building materials include composite roof shingles, painted stucco finish, metal canopies, vinyl windows, stucco over foam trim details, engineered wood siding, metal balcony railing, and painted metal sectional garage doors. The coordinated exterior color scheme consists of subtle natural tones, with contrasting colors used for accents and details.

Project Access and Parking:

Vehicle access to the project site is provided by an existing signalized shared two-way driveway entrance along Tustin Street. This entry drive connects to a looped private interior roadway and two additional interior roadways off the interior cluster that provide vehicle and pedestrian access to the main entrances and garages of the dwelling units. There is an emergency vehicle access gate that leads to an emergency access easement dedicated to the City of Orange located at the northeast corner of the site and on the adjacent property to the north. The internal roadways include curb, gutter, and intermittent landscape planters. Each unit is provided with an attached two-car garage with 14 unenclosed on-lot parking spaces dedicated for four bedroom units, and 23 unenclosed guest parking spaces, for a total of 179 parking spaces provided for the development. The project provides 5 spaces in excess of the 174 parking spaces required by the Small Lot Subidivison Ordinance. Also, one additional dedicated postal service parking space is provided at the entrance to the common open space area.

Pedestrian access from Tustin Street is provided via an existing paved sidewalk/walkway along the south side of the entrance driveway that connects to a network of interior walkways that lead to unit entries and common open space amenities. The project is also within walking distance to nearby shopping, restaurants, office, and residential uses, as well as adjacent to multiple bus stops located on the east and west sides of Tustin Street in the general vicinity of the project site. The private interior roadways, open parking spaces, common open space, and landscape areas designated on Sheet HM (HOA Maintenance Exhibit) of Attachment 8 will be maintained by a Homeowner’s Association for the development.

Common and Private Open Space:

The Small Lot Subdivision development standards require a project to provide common open space only if the buildings on each lot exceed 75% lot coverage. As noted on Sheet SP (Site Plan) of Attachment 8, lot coverage for the project ranges from 25 to 55.7% and therefore the project is not required to provide common open space. However, in an effort to enhance the project aesthetics and provide amenities to the residents, the applicant has provided a common open space area with shaded picnic tables, multipurpose lawn area, mailboxes, and bicycle parking across from the main entrance to the development. The project also provides private open space in the form of roof decks for all units in the interior cluster, and 10-foot rear yards for units along the northern, southwestern, and southern boundaries.

Landscaping
Sheet L-7 (Schematic Existing Tree Plan) of Attachment 8 shows the removal of 68 existing mature trees in order to accommodate the new residential development. A total of 12 existing Palm trees and landscaping will be protected in place along both sides of the shared main entrance driveway.

Sheets L-4 - L-5B (Schematic Planting Plan and Plant Images) of Attachment 8 illustrates the City of Orange Page 5 of 10 Printed on 4/2/2026
powered by Legistar™2070
Item #: 3.1. 4/6/2026 File #: 26-0167
Sheets L-4 - L-5B (Schematic Planting Plan and Plant Images) of Attachment 8 illustrates the proposed water efficient landscape palette for the project. The project incorporates 126 new trees, including Date Palms, Jacaranda, Southern Magnolia, Crape Myrtle, and Marina Strawberry trees, with a mix of shrubs and groundcover, including Big Red Kangaroo Paw, Spanish Lavender, Blue Gem Coast Rosemary, and artifical turf in the common open space area. Private roadway treatment includes the incorporation of Sweet Bay columnar trees between the paired units and similar shrubs and groundcover in the intermittent landscape planters. The landscaping proposed along the interior walkways and paseos provides a friendly pedestrian-oriented interface with the buildings. Enhanced paving is proposed at the main entrance to the development, and in the common open space seating area. Interior walkways will be concrete and four feet wide.

Fences/Walls
Sheet L-3 (Schematic Wall and Fence Plan) of Attachment 8 illustrates existing walls to remain in place along the northern, southern, and southwestern boundaries of the site. A new 8-foot wall with a sliding metal access gate (8 feet tall x 20 feet wide for existing billboard maintenance purposes) is proposed along the eastern boundary, new 6-foot side yard walls with vinyl gates are proposed between units along the perimeter boundaries, and a new 3-foot wall is proposed on the west side of the common open space turf area. No side yard fencing/walls are proposed between units within the interior cluster of homes.

Lighting
Sheets L-9A - L-9B of Attachment 8 include the Photometric Plan and fixture designs for the project.

New 15-foot-tall LED pole streetlights are proposed in landscape planters at the project entry, in front of the common open space area, looped roadway, and adjacent to unenclosed resident and guest parking spaces. These fixtures will have shields directed downward to prevent off-site light spillage.

Various landscape lighting, including shade structure down lighting, in-ground flush mounted fixtures, tree and sign up-lighting will also be provided. Decorative LED wall light fixtures (shown on building elevations) are proposed at the front, rear, and side elevations of the residences within the center cluster, and on the front and side elevations on the perimeter boundaries. The proposed fixture styles are contemporary and compatible with the architecture of the buildings.

Signage
Conceptual signage is included for illustrative purposes on Sheet L-3 of Attachment 8 and is not part of this project proposal. A new 6-foot stucco entry pilaster with development identification signage is proposed on the north side of the project entry. The sign concept appears compatible with the building design; however, the City’s Building Security Ordinance will likely require a lighted address on the sign and at each residential unit. All signage will comply with the City’s sign regulations.

Overall, the project’s coordinated architectural style, use of matching colors and materials for all structures, as well as landscape design as proposed presents an integrated design theme. The project provides a residential design that is distinctive, yet compatible with the commercial and neighborhood area context.

6. PROJECT ANALYSIS
The project as proposed complies with the OMC and the City’s Small Lot Subdivision Development Standards and Guidelines (See Table on Sheet SL of Attachment 8).

The project site has been vacant for two years with no viable lease or commercial development City of Orange Page 6 of 10 Printed on 4/2/2026
powered by Legistar™2071
Item #: 3.1. 4/6/2026 File #: 26-0167
The project site has been vacant for two years with no viable lease or commercial development options despite continuous efforts by the property owner. In order to support redevelopment of the property with the proposed residential project as opposed to the continuance of commercial uses at the site, the applicant has submitted a Fiscal Impact Analysis by Stanley R. Hoffman Associates, Inc. (Attachment 6), which demonstrates a positive economic impact to the City including an annual recurring net contribution to the City’s general fund and one-time development impact fees. The study also indicates that “the project will have a stabilizing effect on the neighborhood through community ties and economic development benefits from new household spending on goods and services captured within the City”.

Land Use
The proposed General Plan Amendment and Zone Change are necessary to allow for residential development on this site. The presence of residential uses along this portion of Tustin Street is logical given the already existing residential development to the north and south of the site, as well as the neighborhood-serving goods and services in the area. The MDR General Plan designation and R-3 zoning are consistent with the General Plan and zoning designations of the existing abutting residential land use to the north (Park 72 Condominiums, 1800 E. Heim Avenue) and the abutting R3 zoning (Coco Palms Condominiums, 2295 N. Tustin Street) to the south, and generally compatible with commercial land uses that would remain to the west, which accommodates a mix of retail and service commercial uses and professional offices. The land use changes also enable the implementation of the Small Lot Subdivision Development Standards, which allows for alternative infill housing typologies within multiple-family residential zones.

The proposed small lot development is also consistent with the intent of the MDR land use designation and R-3 zoning, in that the project provides private and common open space with amenities, a pedestrian-friendly integration along Tustin Street, is adjacent to public transportation, and is in close proximity to commercial, retail, medical and professional offices, and recreational uses.

Project Design
Because of the project’s flag lot configuration, the three-story residential units will be set back more than 220 feet from the Tustin Street right-of-way and partially buffered by existing one-story commercial buildings along the street frontage (Orange Village Dentistry at 2393 N. Tustin Street and new bank building under construction at 2355 N. Tustin Street). Residential developments to the north and south are similarly located and buffered by commercial development. This substantial setback directs the project’s three-story massing away from the Tustin Street right-of-way containing primarily one-story commercial buildings, and does not visually affect the existing appearance of the Tustin Street corridor.

The project’s site configuration includes three-story units backing the northern and southern boundaries, abutting one-story condominium and mobile home developments. During initial review of the project, Staff raised concerns to the applicant regarding the potential for shading/shadowing and the loss of privacy for the abutting neighbors. In response, the applicant has provided Shade/Shadow Exhibits and Line of Sight Section details on Sheets A18-19 and A22 of Attachment 8.

Shade and Shadow
City of Orange Page 7 of 10 Printed on 4/2/2026
powered by Legistar™2072
Item #: 3.1. 4/6/2026 File #: 26-0167
Shading/shadowing is a potential impact when a building(s) blocks sunlight from neighboring properties. The CEQA guidelines have not established shade/shadow thresholds of significance, nor has the City of Orange formally adopted thresholds as part of the City’s local CEQA Guidelines; however, the City considers project impacts to be significant if a substantial amount of sensitive uses/areas would be shaded by project related features for three continuous hours or more on any given day during the winter and summer solstice or spring and fall equinox. The residential buildings are considered shadow sensitive areas to account for solar panels and windows providing light into a residence.

The Shade/Shadow Exhibits illustrate existing and proposed effects during the winter solstice (December 21), when the sun is at the lowest point in the sky resulting in the most restrictive time period, and the summer solstice (June 21), when the sun is at its highest point in the sky. It appears that shading/shadowing with project conditions would not affect the abutting multifamily residential properties for more than three hours during the winter and summer solstice from 9:00 a.m. to 3:00 p.m. Shading/shadowing appears to affect only adjacent property drive aisles, unenclosed parking, and enclosed garages, rather than individual living areas.

The Shade/Shadow Exhibits also illustrate that the majority of the project site will be shaded during the winter solstice from 9 a.m. to 3:00 p.m. While the shading would not affect adjacent property uses, Staff encouranged the use of sun sensitive landscaping for sustainability reasons on the project site.

Line of Sight
The proposed three-story units are located approximately 10 feet from the north and south property lines, and between 61 feet, 10 inches to 64 feet away from the single-story condominium living units.

Because the adjacent condominium living units are separated by drive aisles, open and enclosed parking, it appears that there will be no privacy impacts created by the second and third story windows of the new homes as illustrated in Sections A, B and D.

Section C illustrates the proximity of the new three-story homes to the nearest mobile home living area with windows, located at the southeast corner of the site. It appears that there is a 21-foot separation between the units and that there is existing landscaping/tree on the mobile home property that serves as a visual screen from the second and third story windows of the new units, therefore maintaining the privacy of the mobile homeowner.

While the introduction of infill residential development into an existing urban setting comes with complexities related to site planning and community interface, staff believes that the change in General Plan and zoning designations from commercial to residential will have a positive economic impact to the City supported by the applicant’s Fiscal Impact Analysis, and will not visually impact the Tustin Street corridor given the large setback distance from the Tustin Street right-of-way. The architectural design, exterior materials, and landscaping presents a unifying theme and results in an internally consistent design that is compatible with the eclectic mix of styles in the surrounding area.

Further, this residential development project implements the Small Lot Subdivision Development Standards and supports the City’s Regional Housing Needs Allocation (RHNA) by adding units to the overall housing inventory on a site that had not previously been identified as a Candidate Housing Site in the Housing Element.

City of Orange Page 8 of 10 Printed on 4/2/2026
powered by Legistar™2073
Item #: 3.1. 4/6/2026 File #: 26-0167

7. AUTHORIZING GUIDELINES
Orange Municipal Code (OMC) Table 17.08.020 depicts the authority of the City’s reviewing bodies to make decisions and/or recommendations on land use applications. This project involves applications for a General Plan Amendment, Zone Change, Tentative Tract Map, Major Site Plan Review, Administrative Design Review, and Environmental Review which require a final determination by the City Council. Table 17.08.020(b) states that when more than one type of application is filed for a single project, the application requiring the highest level of approval shall dictate the review process for the entire group of applications. Therefore, the Planning Commission is to act in an advisory capacity to the City Council for the sum of applications for the project because the City Council is the final decision-maker for the General Plan and zoning change.

8. PUBLIC NOTICE
Notice was provided to property owners, tenants, and persons specifically requesting notice and posted at the site on or before March 12, 2026. The notice was also published in the Anaheim Bulletin newspaper on March 12, 2026.

9. ENVIRONMENTAL REVIEW
Click or tap here to enter text.

Mitigated Negative Declaration: Mitigated Negative Declaration (MND) No. ENV25-0001 (SCH No. 2026020142) was prepared to evaluate the physical environmental impacts of the project, in conformance with the provisions of the California Environmental Quality Act (CEQA) per State CEQA Guidelines Section 15070 and in conformance with local CEQA guidelines. The analysis contained in MND No. ENV25-0001 determined that the project will have less than significant impacts to the environment with the implementation of Project Design Features, Plans, Programs, and Policies, relating to Aesthetics, Air Quality, Cultural Resources, Energy, Geology and Soils, Greenhouse Gas Emissions, Hydrology and Water Quality, Noise, and Tribal Cultural Resources, and Mitigation Measures relating to Biological Resources, Noise, and Tribal Cultural Resources.

The Mitigation Monitoring and Reporting Program of the Final MND summarizes the Project Design Features, Plans, Programs and Policies, Mitigation Measures, and the responsible party for the implementation and monitoring (Attachments 9 and 10). On February 5, 2026, a Notice of Intent (NOI) to Adopt Mitigated Negative Declaration No. ENV25-0001 was filed with the Orange County Clerk Recorder, posted at the site, mailed to property owners and tenants within a 300-foot radius of the project site, potentially affected cities, public agencies, utility service providers, and published in the Anaheim Bulletin newspaper on February 5, 2026. The public review period began on February 5, 2026, and ended on February 25, 2026. The MND was made publicly available at the Community Development Department, City Clerk’s office, and the City’s website.

Public comments on MND No. ENV25-0001 were received from the California Department of Transportation (Caltrans), Pala Band of Mission Indians, and six community members. Caltrans recognizes that the pattern of land use can affect both local vehicle miles traveled and number of trips, and supports local developments that promote equity, strengthen the economy, protect the environment, and provide a diversity of housing choices accessible to transportation facilities, promote the design of Complete Streets with high-quality pedestrian, bicycle, and transit facilities, describes the project adjacency to bike lanes, supports inclusion of secure and functional short term bike parking and provides guidance on bicycle parking best practices, indicates that work within Caltrans right-of-way will require discretionary approval, and requests coordination with Caltrans on City of Orange Page 9 of 10 Printed on 4/2/2026
powered by Legistar™2074
Item #: 3.1. 4/6/2026 File #: 26-0167
Caltrans right-of-way will require discretionary approval, and requests coordination with Caltrans on future projects. The Pala Band of Mission Indians commented that the project is not within the boundaries of the recognized Pala Indian Reservation and beyond the boundaries of the Traditional Use Area and requests to receive project notifications. Community members provided general comments related to traffic, parking, privacy, rezoning and reduction of sales tax revenue, waste management, construction noise, site demolition impacts, emergency access, property values, need for more restaurant and retail uses, project should have a commercial component, and noted corrections and/or modifications to the IS/MND document. Responses to comments were prepared and forwarded to the respective authors in accordance with the requirements of CEQA, and in advance of the City’s consideration of any determination. Copies of the comment letters and responses to comments to address feedback relevant to environmental impacts received during the public review period were incorporated into the final MND (Attachment 9).

10. ADVISORY BOARD ACTION
Staff Review Committee:

The interdepartmental Staff Review Committee (SRC) conducted reviews of the project on September 17, 2025, May 7, 2025, and October 29, 2025. On January 29, 2026, SRC recommended that the project proceed to the Planning Commission.

11. ATTACHMENTS · Attachment 1 Planning Commission Resolution No. PC 08-26 · Attachment 2 Planning Commission Resolution No. PC 09-26 · Attachment 3 Planning Commission Resolution No. PC 10-26 · Attachment 4 Vicinity Map
· Attachment 5 Applicant’s Letter of Explanation
· Attachment 6 Fiscal Impact Analysis, dated December 12, 2025 · Attachment 7 Existing Site Photographs
· Attachment 8 Project Plans, received on December 17, 2025 · Attachment 9 Final Mitigated Negative Declaration No. ENV25-0001 and Mitigation Monitoring and Reporting Program, dated March 2026
· Attachment 10 Mitigated Negative Declaration No. ENV25-0001 Appendices · Attachment 11 Small Lot Subdivision Guidelines
· Attachment 12 Color and Material Boards; Physical Boards Provided at Meeting City of Orange Page 10 of 10 Printed on 4/2/2026
powered by Legistar™2075
City of Orange
Planning Commission
April 06, 2026

MINUTES - DRAFT
The Planning Commission of the City of Orange, California convened on April 6, 2026, at 5:30 p.m. in a Regular Meeting in the Council Chamber, 300 E. Chapman Avenue, Orange, California.

1. OPENING/CALL TO ORDER
Vice Chair Tucker called the meeting to order at 5:33 p.m.

1.1 PLEDGE OF ALLEGIANCE
Commissioner Tim McCormack led the flag salute.

1.2 ROLL CALL

Present: Tucker, Vazquez, Martinez, Maldonado, Vejar, and McCormack

Absent: Leslie

2. PUBLIC COMMENTS
None.

3. PUBLIC HEARINGS

3.1. Public Hearing to consider a proposal to redevelop a commercial property with 71 small lot single-family homes at 2375 N. Tustin Street. An Initial Study/Mitigated Negative Declaration was prepared in conformance with CEQA (GPA25-0003, ZC25-0002, TTM25-0001, MJSP25-0002, ADR25-0018, and ENV25-0001).

Principal Planner, Monique Schwartz, presented a summary of the proposed project.

Vice Chair Tucker opened the public hearing at 5:46 p.m.

Applicant Chad Brown gave a presentation on the project.

Public Speakers:

The following spoke in opposition of the project: Lisa Ackerman Baldwin, Adrienne Gladson and Cynthia Hesketh
The following spoke in favor of the project: Jeff Weber Vice Chair Tucker closed the public hearing at 6:52 p.m.

Commissioners discussed preservation of privacy for the adjacent neighbors; project

Page 1 of 3 ends
← All documents from this meeting