127(

 7+(5(48,5('&/($5)/22563$&(0$<12729(5/$37+(5(48,5(' .1((63$&(%<025(7+$1

 .1((&/($5$1&(6$77$%/(6&2817(56 :25.685)$&(6,6$7/($67 +,*+:,'($1'
'((3
5()
&%&%
(/(9$7,21 3/$1

0,1
0,1
0,1
0,1 0,1

0,1
0,1
0,1&/5
0,1
0$;
38//6,'(
386+6,'(

0,1&/5,)'225+$6%27+$/$7&+$1'$&/26(5
+
-.
0,1
0,1
5()
&%&%
0,1&/5 0,1&/5
38//6,'(
386+6,'(

0,1&/5,)'225+$6%27+$/$7&+$1'$&/26(5
)*
'

5()

&%&%
0,1&/5
0,1&/5 0,1&/5
0,1
386+6,'(
38//6,'(

3529,'(7+,6$'',7,21$/63$&(,)'225,6(48,33(':,7+%27+$/$7&+$1'$&/26(5 %&

$

127(

$//'2256,1$/&29(6
6+/$/&203/<:,7+7+(&/($5$1&(6)25)5217
$3352$&+(6
5()
&%&%
0,1&/5 0,1&/5
$7(;7(5,256,'(2)(;7(5,25'2256
0,1&/5
$7,17(5,25'2256
0,1&/5
0,1
&/5

&/5

,1&+(6',$0(7(563$&( 0,1,080&/($5:,'7+
76+$3('63$&()25'(*5((78516
 0,1 &/5 ',$
5()
&%&% 
%
0,1&/5
&/5
0,1
0,1&/5
&21732,17
0$;
0,1&/5
0,1&/5
0,1;&/($563$&()25)5217$3352$&+
0,1&/5
.1((&/($5$1&(
720$;
7$%/(25&2817(5+(,*+7 
0,1'(37+
.1((72(&/($5$1&(
 0,1 &/5

&
 0,1 /5
127(
 7+(5(48,5('&/($5)/22563$&(0$<12729(5/$37+(5(48,5(' .1((63$&(%<025(7+$1

 .1((&/($5$1&(6$77$%/(6&2817(56 :25.685)$&(6,6$7/($67 +,*+:,'($1'
'((3
127(
'225&/26(56,)35(6(170867%(6(7627+$7,77$.(6'225$7/($676(&21'672&/26()520$123(1326,7,212) '(*5((672:,7+,1ƒ2)/$7&+7+()25&(7223(1'2256+$//127(;&(('/%67<3,&$/ '225&/26(56
$&&(37$%/('225
+$5':$5($1'
02817,1*+(,*+76
3$1,&
/223
/(9(5




ƒ
5()
&%&%
$))
.,&.3/$7(
127(
6:,1*,1*'225 *$7(685)$&(6:,7+,12)),1,6+)/2256+$//+$9( $60227+685)$&(2)7+(386+6,'((;7(1',1*7+()8//:,'7+2) '22525*$7(3$576&5($7,1*+25,=217$/259(57,&$/-2,1766+$//%(:,7+,12)685)$&( 6+$//%()5((2)6+$5325$%5$6,9(('*(6&$9,7,(6&5($7('%<.,&.3/$7(66+$//%(&$33(' ))
5()
&%&%
0,1
0,1
0$;
0$; 0$;
0$;
;”0$;
812%6758&7(')25:$5'5($&+
2%6758&7('+,*+)25:$5'5($&+
5()

&%&%
0,1
0$; 0$; 0$; 0$; ;”0$; 812%6758&7('6,'(5($&+ 2%6758&7('+,*+6,'(5($&+
0$;
0$; 0$;
5()

&%&%
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
$&&(66,%,/,7<'(7$,/6
*

-+
-5

-5
*
 6&$/(
 

 72( .1((&/($5$1&(6
*
 6&$/(
 

 /$7&+$3352$&+&/($5$1&(6
*
 6&$/(
 

 +,1*($3352$&+&/($5$1&(6
*
 6&$/(
 

 )5217$3352$&+&/($5$1&(6
*
 6&$/(
 

 7851,1*63$&(
*
 6&$/(
 

 &2817(5723&/($5$1&(6
*
 6&$/(
 

 $&&'2255(48,5(0(176
*
 6&$/(
 

 $&&'225.,&.3/$7(
*
 6&$/(
 

 $&&)25:$5'5($&+
*
 6&$/(
 

 $&&6,'(5($&+

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 236 of 1531 ends

*5$3+,&6
(YHU\H[LWVLJQDQGGLUHFWLRQDOH[LWVLJQVKDOOKDYHSODLQO\OHJLEOHOHWWHUVQRWOHVV WKDQLQFKHV
PP
KLJKZLWKWKHSULQFLSDOVWURNHVRIWKHOHWWHUVQRWOHVVWKDQLQFK 
PP
ZLGH7KHZRUG(;,7VKDOOKDYHOHWWHUVKDYLQJDZLGWKQRWOHVVWKDQLQFKHV PP
ZLGHH[FHSWWKHOHWWHU,DQGWKHPLQLPXPVSDFLQJEHWZHHQOHWWHUVVKDOOEHQRWOHVVWKDQLQFK

PP
6LJQVODUJHUWKDQWKHPLQLPXPHVWDEOLVKHGLQWKLVVHFWLRQVKDOOKDYHOHWWHUZLGWKVVWURNHVDQGVSDFLQJLQSURSRUWLRQWRWKHLUKHLJKW7KHZRUG(;,7VKDOOEHLQKLJKFRQWUDVWZLWKWKHEDFNJURXQGDQGVKDOOEHFOHDUO\ GLVFHUQLEOHZKHQWKHPHDQVRIH[LWVLJQLOOXPLQDWLRQLVRULVQRWHQHUJL]HG,IDFKHYURQGLUHFWLRQDOLQGLFDWRULVSURYLGHGDVSDUWRIWKHH[LWVLJQWKHFRQVWUXFWLRQVKDOOEHVXFKWKDWWKHGLUHFWLRQRIWKHFKHYURQGLUHFWLRQDOLQGLFDWRUFDQQRWEHUHDGLO\FKDQJHG 0,1+(,*+7
0,163$&,1*
0,16752.(

(;&(37)25/(77(5,

0,1/(77(5:,'7+
&%&
,17(51$//<,//80,1$7('6,*16(OHFWULFDOO\SRZHUHGVHOIOXPLQRXVDQGSKRWROXPLQHVFHQWH[LWVLJQVVKDOOEHOLVWHGDQGODEHOHGLQDFFRUGDQFHZLWK8/ DQGVKDOOEHLQVWDOOHGLQDFFRUGDQFHZLWKWKHPDQXIDFWXUHU VLQVWUXFWLRQVDQG&KDSWHU([LWVLJQVVKDOOEHLOOXPLQDWHGDWDOOWLPHV &%&
(;7(51$//<,//80,1$7('(;,76,*16([WHUQDOO\LOOXPLQDWHGH[LWVLJQVVKDOOFRPSO\ZLWK6HFWLRQVWKURXJK &%&
:+(5(5(48,5('([LWVDQGH[LWDFFHVVGRRUVVKDOOEHPDUNHGE\DQDSSURYHGH[LWVLJQUHDGLO\YLVLEOHIURPDQ\GLUHFWLRQRIHJUHVVWUDYHO7KHSDWKRIHJUHVVWUDYHOWRH[LWVDQGZLWKLQH[LWVVKDOOEHPDUNHGE\UHDGLO\YLVLEOHH[LWVLJQVWRFOHDUO\LQGLFDWHWKHGLUHFWLRQRIHJUHVVWUDYHOLQFDVHVZKHUHWKHH[LWRUWKHSDWKRIHJUHVVWUDYHOLVQRWLPPHGLDWHO\YLVLEOHWRWKHRFFXSDQWV,QWHUYHQLQJPHDQVRIHJUHVVGRRUVZLWKLQH[LWVVKDOOEHPDUNHGE\H[LWVLJQV([LWVLJQSODFHPHQWVKDOOEHVXFKWKDWDQ\SRLQWLQDQH[LWDFFHVVFRUULGRURUH[LWSDVVDJHZD\LVZLWKLQIHHW PP
RUWKHOLVWHGYLHZLQJGLVWDQFHRIWKHVLJQZKLFKHYHULVOHVVIURPWKHQHDUHVWYLVLEOHH[LWVLJQ(;&(37,216  ([LWVLJQVDUHQRWUHTXLUHGLQURRPVRUDUHDVWKDWUHTXLUHRQO\RQHH[LWRU H[LWDFFHVV
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
',5(&7,21$/&+(95216+$//127%(5($',/<&+$1*('5()(572&2'(3/$1)25,1',&$7('',5(&7,21 5220,'
'(37+

5$,6('0,1$%29(%$&.*5281'
&+$5$&7(56

833(5&$6(6$16(5,)127,7$/,& :,'7+2)6+$//%(0,1720$;2) +(,*+7

5220,'7(;772%(+,*+7<3
6752.(

7+,&.1(662)6+$//%(0$;2)+(,*+7
0,10$;&255(6321',1**5$'(,,%5$,//(
127(
3(50$1(176,*1$*(72%(,167$//('217+(:$//
$'-$&(17727+(/$7&+
6,'(2)7+('22502817,1*/2&$7,210867
$//2:$3(562172$3352$&+:,7+287
(1&2817(5,1*352758',1*2%-(&762567$1',1*:,7+,17+(6:,1*3$7+2)7+('225 0$;
 
&+$5$&7(563$&,1*
:,'7+0$;5(&7$1*8/$5
0,1727,0(66752.(
6752.(:,'7+0$;
0,1727,0(6
1215(&7$1*8/$5 5(&7$1*8/$5
5220
0,1
64&/5)/225$5($&(17(5('216,*1 &/($52)'2256:,1* ,167$//$7,21+(,*+7$1'/2&$7,21
5$,6('&+$5$&7(56
5()

&%&%
(;,7
(;,76,*1$*(
0,1
'(37+

5$,6('0,1$%29(%$&.*5281'
&+$5$&7(56

833(5&$6(6$16(5,)127,7$/,& :,'7+2)6+$//%(0,1720$;2) +(,*+7

7(;772%(+,*+7<3
6752.(

7+,&.1(662)6+$//%(0$;2)+(,*+7
0,10$;

  
127(
5()(5726+((7$
$1''2256&+('8/()25
52206,*1'(6,*1$7,216
$1'/2&$7,21
6<0%2/3523257,216
),*85(%,17(51$7,21$/6<0%2/
5()%
5()
&%&

$//7(;7*5$3+,&672%($3(50$1(173$572)7+(6,*1)2552206,*15(48,5(0(1763/$1)25/2&$7,21 0$;,080
2&&83$1&< 






 
 

5$',867<3+,*+7(;7&+$5$&7(5663$&('$3$57+,*+7(;79(5,)<0(66$*(35,2572)$%5,&$7,21 &

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
$&&(66,%,/,7<'(7$,/6
*

-+
-5

-5
*
 6&$/(
 

 $&&,//80,1$7('(;,76,*1
*
 6&$/(
 

 $&&52206,*1$*(
*
 6&$/(
 

 ,17/6<0%2/2)$&&
*
 6&$/(
 

 0$;2&&83$17/2$'
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 237 of 1531 ends

127(6

 +27:$7(5$1''5$,13,3(681'(5$&&(66,%/(
/$9$725,(66+$//%(,168/$7('2527+(5:,6(&29(5('7+(5(6+$//%(126+$5325$%5$6,9(685)$&(681'(5/$9$725,(6  7+(',32)7+(29(5)/2:6+$//127%(&216,'(5(',1 '(7(50,1,1*.1(( 72(&/($5$1&(6
 6,1.6+$//%('((30$; 23(5$%/(3$5762)62$32527+(5',63(16(56 /2&$7('217+(%$&.:$//2)7+(/$9$725<$5(:,7+,15($&+5$1*()IO0$;,080$))$1'IO IO0$;,080'((3'(3(1'(17832172(&/($5$1&(%(/2:3(5&%&  ',63(16(5602817('217+(*5$%%$56,'(2)
$&&(66,%/(72,/(76+$//127352-(&7025(7+$1
)520)$&(2):$//125%(/2&$7('&/26(57+$1&/($52)%277202)*5$%%$5 )$8&(7$&&(66,%,/,7<127(6

&21752/6)25)$8&(766+$//&203/<:,7+&%&%

 )$8&(76&21752/6$1'23(5$7,1*0(&+$1,6066+$//
%(23(5$%/(:,7+21(+$1'$1'6+$//1275(48,5(7,*+7*5$63,1*3,1&+,1*257:,67,1*2)7+(:5,67  7+()25&(5(48,5('72$&7,9$7(&21752/66+$//%(
12*5$7(57+$13281')25&(
1
/(9(523(5$7('386+7<3($1'(/(&7521,&$//<&21752//('0(&+$1,606$5((;$03/(62)$&&(37$%/('(6,*166(/)&/26,1*9$/9(6$5($//2:(',)7+()$8&(75(0$,1623(1)25$7/($676(&21'6 3 ))
)
,
5 ((;
7 ,
1*8
,
6 +
(
5 0
))
-
.
(/(9$7,21 0,1
0,1
)25:$5'
$3352$&+&/($5
)/22563$&(
3/$1
)/86+9$/9(
7232)%2:/
0,1
0,5525
6($7&29(5
',63(16(5
6$1,7$5<1$3.,1
',63(16(5
72:(/
',63(16(5
(/(&75,&
'5<(5
75$6+
5(&(37$&/(
&83
',63(16(5
3 ))
5()%
)(
6,'(*5$%%$5
72,/(73$3(5',63
&
'
0,1 0$;
,1)52172)72,/(7
0,1
'
0,1
$
),1,6+(':$//
6,'(9,(:3/$19,(:
0,1
5(48,5('&/($563$&(
)
2 )





0 1
,

&
/
5 
0,1
*


0 1
,

&
/
5 
72(&/5
0$;
0,1
0,1.1((&/5
5(48,5('&/($563$&(5(029$%/(&$%,1(7)$&(
:+(5(2&&856

+
(;7(1'),1,6+(')/22572:$//
+

)52172)7+(+,*+(52)7+(5,025&2817(5685)$&(
&%&%

5($5*5$%%$5
  
0,1
*
),1,6+(':$//
/
),5((;7,1*8,6+(5 '5,1.,1*)2817$,1
'22502817('6,*1$*(
7<3

3,&72*5$06$1'25/(77(5,1*$5(1275(48,5('21'22502817('6,*1$*( 

&/
:20(10(181,6(;


',$0(7(5
&(17(5
/,1(2)6,*1
&(17(5
/,1(2)'225$7(,7+(56,'(
:,7+,1



0 $
;




0 1
,




0 1
,




0 1
,

0,1
0,1 0,1&/5
0,1
 0$;
[
&/($5
)/225
/$1',1*
 0,1 &/5
0,10$;
)/86+
$&7,9$725
2175$16)(56,'(
5()&%&%



0 $;:$//)5$0,1* 5()(572)/225 3/$1)25:$//7<3(6
:$//),1,6+ 5()(572),1,6+6&+('8/(&21&($/(')$67(1(560,1:22'6&5(::,7+3(1(75$7,21,172%/2&.,1*0,1 0$;',$%/2&.,1*,1:$// 
0,172352-(&7,21$%29(
)256+2:(5&21752/625*5$%%$56
0,172352-(&7,21%(/2:6(253529,'(&$/&672-867,)<$//&20321(176$1'&211(&7,216,17+,6'(7$,/ 3(1(75$7,21




0 1
,






:$//02817('6,*1$*(72%(/2&$7('21/$7&+6,'(2)'225&/($52)'2256:,1*02817$70,1$1'0$;)5207+(%$6(/,1(2)7+(+,*+(67/,1(2)5$,6('&+$5$&7(56 '22502817('
6,*1$*(:,7+,1
2)
&(17(5/,1(2)
'225
/(77(5,1*
5$,6('
0,1
833(5&$6(6$166(5,)&+$5$&7(56+(,*+72)/(77(5,1*0,1720$; 5(675220
0,10$;
&255(6321',1*
*5$'(,,%5$,//(
5220,'(17,),&$7,216,*15()(5725220,'6,*1'(7$,/
5()% 


01 ,




0 $
;
81,6(;
5(675220



0 $
;

:$//6,*1$*(
'22502817('*(20(75,&6<0%2/6
)25$'',7,21$/*(20(75,&6<0%2/,1)250$7,21
5()72
*

)25$'',7,21$/5220,'6,*1,1)250$7,21
5()72
*

$ 72,/(7&/)520:$//  / /2:'5,1.,1*)2817$,1
$3352$&+
3(5%
% 72,/(76($7+(,*+7 
 63287+(,*+7$1'/2&$7,21
)520('*(2)81,7,1&/8',1*%803(56
0$;$)) 
0$;)520)5217
('*(2)81,7
& 7232)*5$%%$5*5,33,1*
685)$&(
 '5,1.,1*)2817$,123(5$%/(
3$576)520)5217('*(2)7+(81,7
0$;
' )857+(6772,/(73$3(5,1
)52172)72,/(7

$7&/ 0 '5,1.,1*)2817$,1.1((
&/($5$1&(
0,1&/5
' ',63(16(5+(,*+7 

( 6$1,7$5<1$3.,1',6326$/

+,*+(6723(5$%/(3$57$))


0,1 3 ',63(16(5623(5$%/(3$576 0$;
) 0,5525 %272)5()/(&7,9(
685)$&($))
0$;:+(1
$%29(6,1.25
&2817(5723
0$;12/$9
4 5($&+5$1*( )5217 6,'(
$3352$&+
0$;
* /$9$725<6,1.5,0+(,*+7 0$; 5 %277202)23(1,1*287/(7  0,1
+ /$9$725<.1((&/($5$1&( 0,1$7'(37+

0,1$7$3521
6 72(&/($5$1&($772,/(7
3$57,7,21

0,1
- 85,1$//,3+(,*+7 0$; 7 72,/(7)/86+&21752/+(,*+7 . 85,1$/)/86++$1'/(+(,*+7 0$;
67$1'$5'+(,*+7)2817$,1$&&(66,%/()2817$,1
7+(632876+$//3529,'($)/2:2):$7(5+,*+0,1$1'6+$//%(/2&$7('0$;)5207+()52172)7+(81,77+($1*/(2)7+(:$7(5675($06+$//%(0($685('+25,=217$//<5(/$7,9(727+()5217)$&(2)7+(81,7:+(5(632876 $5(/2&$7('/(667+$1,1&+(6)5207+()52172)7+(81,77+($1*/(2)7+( :$7(5675($06+$//%('(*5((60$;:+(5(632876$5(/2&$7('%(7:((1,1&+(6$1',1&+(60$;)5207+()5217217+(81,77+($1*/(2)7+(:$7(5675($06+$//%('(*5((60$; 0$;
0,1&/5
0$;

0$; 0,1
23(5$%/(3$5766+$//&203/<:,7+%
7+()/2:2):$7(56+$//%($&7,9$7('%<$0$18$//<23(5$7('6<67(0)521702817('256,'(02817(' /2&$7(':,7+,12)7+()5217('*(2)7+()2817$,125$1$8720$7,&(/(&7521,&$//<&21752//(''(9,&( 0,10$;
72($1'.1((&/($5$1&(6+$//%(3529,'('$63(5%6(('(7$,/ 5()%
02817,1*6+$//%(3(50$18),17262/,'%$&.,1*3/$7(
$&&(66,%/(%277/(),//(5
:+(5(2&&8565()(572'(7$,/ 5()72
*

 0,1 &/5  0,1 ,) $/&29( '(37+ ,6 !
0,1
$&&(66,%/(:$7(5
),//(567$7,21
23(5$%/(3$5766+$//&203/<:,7+%
7+()/2:2):$7(56+$//%($&7,9$7('%<
$0$18$//<23(5$7('
6<67(0)521702817('256,'(02817(' /2&$7(':,7+,12)7+()5217('*(2)7+()2817$,125$1$8720$7,&(/(&7521,&$//<&21752//(''(9,&( 5()%
02817,1*6+$//%(3(50$18)$&785(5,17262/,'%$&.,1*3/$7( 0$;
 0,1 &/5 )25 )5217 $3352$&+
0$;726(1625
(4
(4 &/  0,1 &/5 )25 )5217 $3352$&+
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
$&&(66,%,/,7<'(7$,/6
*

-+
-5

-5
*
 6&$/(
 

 ),;785($1'$&&(6625,(602817,1*+(,*+76$1'&/($5$1&(6 *
 6&$/(
 

 5(675220*(20(75,&6<0%2/6
*
 6&$/(
 

 $&&6,1*/($&&202'$7,2172,/(7
*
 6&$/(
 

 $&&*5$%%$5$77$&+0(17
*
 6&$/(
 

 5(6752206,*1$*(

*
 6&$/(
 

 +,/2'5,1.,1*)2817$,1
*
 6&$/(
 

 :$7(5%277/(),//(567$7,21
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 238 of 1531 ends

     
EO G F R U        EO G F R U (9 (9
(9
+26( %,%
3)
6,7(3/$1/(*(1'
(;,67,1*&21&5(7(3$9,1*(;,67,1*3/$17,1*$5($
67$1'$5'$&&(66,%/(67$//
(9 (/(&75,&$/9(+,&/(&+$5*,1*67$//
9$1$&&(66,%/(67$// 9$1
$&&(66,%/(3$7+2)75$9(/
6+$//%(0,1&%&%
($670(176(7%$&.3523(57</,1(%8,/',1*)22735,17
:$/187
(;,67,1*

(;,67,1*
6)
12&+$1*(

9%&216758&7,217<3(
6725,(6
(;,67,1*3$5.,1*
121(::25.
(;,67,1*3$5.,1*
121(::25.
0
%(
%)
%*
8


(;,67,1*3$5.,1*
121(::25.

8

(;7(5,25$5($2)$66,67('5(6&8(3(5
126(3$5$7,215(48,5('3(5
(;&(37,21
)(1&(*$7(352-(&781'(56(3$5$7(3(50,76+2:1)255()(5(1&(21/< 




















&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
$5&+,7(&785$/6,7(3/$1
$6
-+
-5

-5
.(<127(6
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(5720(&+$1,&$/3/$16)25)857+(5,1)250$7,21 5()(572(/(&75,&$/3/$16)25)857+(5,,1)250$7,21 $//6,'(:$/.6&5266:$/.6&20021$5($6$1'%8,/',1*(175$1&(6 6+$//%($&&(66,%/($1',1&203/,$1&(:,7+&%&%$ )/225$1'*5281'685)$&(66+$//%(67$%/(),50$1'6/,3 5(6,67$17
% 23(1,1*6,1)/22525*5281'685)$&(66+$//127$//2: 3$66$*(2)$63+(5(
& 9(57,&$/&+$1*(6,1/(9(/6+$//127(;&(('' 7+(&/($5:,'7+)256,'(:$/.6$1':$/.66+$//%(0,1  $//&85%,1*127:,7+,1$3$5.,1*63$&(6+$//%(3$,17('5('72 '(6,*1$7(7+(),5(/$1(6
6,7(3/$1*(1(5$/127(6
$6 6&$/(
 

 6,7(3/$1
:$/18767
6$17$526$67
%( (;,67,1*$&&(66,%/(3$5.,1*725(0$,1%) (;,67,1*'5,9($3352$&+725(0$,1%* (;,67,1*&85%$1'*877(50 (;,67,1*&85%5$03725(0$,18 (;,67,1*$&&(66,%/(3$7+2)75$9(/725(0$,1 5(48,5('3$5.,1*
)81&7,21 $5($
0,15(48,5('
3(5
727$/3$5.,1*
5(4
'
727$/3$5.,1*
3529,'('
2)),&(
 3(56)  
&

5(1(:$/'$7(

/
/ . # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 239 of 1531 ends

(;,67,1*678')5$0(':$//725(0$,1
:$//7<3(6/(*(1'
$$$ (;,67,1*:$//)855,1*725(0$,1$ (;,67,1*0$6215<%/2&.:$//725(0$,1$ (;,67,1*&21&5(7(:$//725(0$,1$ (;,67,1*6725()5217:$//725(0$,1 1(:67((/678')5$0(',17(5,253$57,7,21:*<3%2$5'($&+6,'($&2867,&%$77,168/$7,216(($ )25'(7$,/6
$ (;,67,1*0$6215<%/2&.:$//725(0$,1

$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

%85($8
6(5*($17

0((7,1*

2)),&(

'521((48,3
6725$*(

'(7(&7,9(
(48,30(17

(/(&75,&$/

:20(1


0(1

+$//

-$1

+$//

6725$*(

67$,5

67$,5

%5,(),1*
5220

+$//


/2%%<

(/(9

6+$5('
2)),&(

$
$$
$ $
$$
$
$
$
$
%'
-
$
&
'
$

&-

$6
$5
&-
'(02 ,17(5,25 &$53(7
'(02(;,67,1*3$57,7,2125:$//),1,6+'(02 ,17(5,25/,12/(807,/('(02 ,17(5,25 7,/(,17(5,25 &$53(7 725(0$,1 127(
5()(572,17(5,25),1,6+6&+('8/(6216+((76
$ $)25$''7,21$/,1)250$7,21
'(02 ,17(5,25 /97
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(02/,7,21),567)/2253/$1
$'
-+
-5

-5
.(<127(6
$5 3257,212)(;,67,1*:$//72%(5(029(')251(:'225 23(1,1*
$6 35(3$5((;,67,1*23(1,1*)251(:678':$//,1),//%' (;,67,1*/,*+7*8$*(0(7$/678':$//72%(5(029('& (;,67,1*&$6(:25.72%(5(029('&- (;,67,1*6725()521772%(5(029('$1'',6&$5'('' (;,67,1*&2817(5723$1'&$6(:25.72%(5(029(' - (;,67,1*6,1.72%(5(029('3527(&7,13/$&((;,67,1* 3/80%,1*)251(:'5,1.,1*)2817$,1$1'%277/(),//(55()(5723/80%,1*)25$'',7,21$/,1)250$7,21  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 )/2253/$1*(1(5$/127(6
 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21,)3529,'(' 5()(5720(&+$1,&$/3/$16'5$:,1*6255(32576 )25)857+(5 ,1)250$7,21
 5()(5723/80%,1*3/$1625'5$:,1*6)25 )857+(5,1)250$7,21,) 3529,'('
 12786(' ',0(16,216$5(72)$&(2)(;,67,1*),1,6+81/(6663(&,),&$//< 127('27+(5:,6(
 3529,'($'(48$7(%/2&.,1*,1:$//6)25&$%,1(76$1'27+(5:$// 02817('$&&(6625,(6,1&/8',1*%87127/,0,7('72+$1'5$,/66+(/9,1*$1'%$7+5220),;785(6  3529,'(),5(%/2&.,1*)25:$//&$9,7,(67+$7(;&(('&%& +(,*+7/,0,7$7,216

 '225$1':,1'2:',0(16,216$5(&(17(5('$723(1,1*6 :+(5('225,6/2&$7(':,7+287',0(16,21$77+(&251(52)$ 5220,76+$//%()520)$&(2))5$0,1*2)$'-$&(17:$//72528*+'22523(1,1*  6((&2'($1$/<6,6)25/2&$7,2162)),5(3$57,7,216$1'),5( %$55,(56
 :+(5(5(&(66('),;785(62&&85,1:$//625+25,=217$/ $66(0%/,(67+(),5(5$7,1*2)7+26($66(0%/,(66+$//%(0$,17$,1('  $7$//3(1(75$7,216$1',17(56(&7,2162)),5(5$7('3$57,7,216 3529,'(),5(6($/$17$1'25),5(67233,1*720$,17$,1&217,18,7<2)3$57,7,215$7,1* $' 6&$/(
 

 '(02/,7,21),567)/2253/$1
)/225'(02/,7,21/(*(1'


&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 240 of 1531 ends

83 (;,67,1*678')5$0(':$//725(0$,1
:$//7<3(6/(*(1'
$$$ (;,67,1*:$//)855,1*725(0$,1$ (;,67,1*0$6215<%/2&.:$//725(0$,1$ (;,67,1*&21&5(7(:$//725(0$,1$ (;,67,1*6725()5217:$//725(0$,1 1(:67((/678')5$0(',17(5,253$57,7,21:*<3%2$5'($&+6,'($&2867,&%$77,168/$7,216(($ )25'(7$,/6
$ (;,67,1*0$6215<%/2&.:$//725(0$,1

$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

$
$
$
$
$
$
$
$
$
$
&,
&$&$
$

$+$+
$
'


&3

'(02 ,17(5,25 &$53(7
'(02(;,67,1*3$57,7,2125:$//),1,6+
'(02 ,17(5,25/,12/(807,/('(02 ,17(5,25 7,/(,17(5,25 &$53(7 725(0$,1 127(
5()(572,17(5,25),1,6+6&+('8/(6216+((76
$ $)25$''7,21$/,1)250$7,21
'(02 ,17(5,25 /97
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(02/,7,216(&21')/2253/$1
$'
-+
-5

-5
.(<127(6
$+ (;,67,1*&2/801725(0$,13527(&7,13/$&($ (;,67,1*3/80%,1*),;785(72%(5(029('&$ '(02(;,67,1**<3%'&2/801:5$37235(3$5()251(:
:$//6
&, (;,67,1*02725,=('352-(&7256&5((172%(5(029('6(7 $6,'($1'3527(&7(')25,167$//$7,21,1&21)(5(1&(
52206((352326('3/$16
&3 5(029((;,67,1*),5((;7,1*8,6+(5&$%,1(735(3$5( 23(1,1*)251(:&$%,1(7
' (;,67,1*&2817(5723$1'&$6(:25.72%(5(029('  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 )/2253/$1*(1(5$/127(6
 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21,)3529,'(' 5()(5720(&+$1,&$/3/$16'5$:,1*6255(32576 )25)857+(5 ,1)250$7,21
 5()(5723/80%,1*3/$1625'5$:,1*6)25 )857+(5,1)250$7,21,) 3529,'('
 12786(' ',0(16,216$5(72)$&(2)(;,67,1*),1,6+81/(6663(&,),&$//< 127('27+(5:,6(
 3529,'($'(48$7(%/2&.,1*,1:$//6)25&$%,1(76$1'27+(5:$// 02817('$&&(6625,(6,1&/8',1*%87127/,0,7('72+$1'5$,/66+(/9,1*$1'%$7+5220),;785(6  3529,'(),5(%/2&.,1*)25:$//&$9,7,(67+$7(;&(('&%& +(,*+7/,0,7$7,216

 '225$1':,1'2:',0(16,216$5(&(17(5('$723(1,1*6 :+(5('225,6/2&$7(':,7+287',0(16,21$77+(&251(52)$ 5220,76+$//%()520)$&(2))5$0,1*2)$'-$&(17:$//72528*+'22523(1,1*  6((&2'($1$/<6,6)25/2&$7,2162)),5(3$57,7,216$1'),5( %$55,(56
 :+(5(5(&(66('),;785(62&&85,1:$//625+25,=217$/ $66(0%/,(67+(),5(5$7,1*2)7+26($66(0%/,(66+$//%(0$,17$,1('  $7$//3(1(75$7,216$1',17(56(&7,2162)),5(5$7('3$57,7,216 3529,'(),5(6($/$17$1'25),5(67233,1*720$,17$,1&217,18,7<2)3$57,7,215$7,1* $' 6&$/(
 

 '(02/,7,216(&21')/2253/$1
)/2250$7(5,$/6/(*(1'
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 241 of 1531 ends



$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

0((7,1*

2)),&(

%85($8
6(5*($17

'521((48,3
6725$*(

'(7(&7,9(
(48,30(17

(/(&75,&$/

:20(1


0(1

+$//

-$1

+$//

6725$*(

67$,5

67$,5

%5,(),1*
5220

+$//


/2%%<

(/(9

6+$5('
2)),&(





%+
$+
$&
$&
&'
%,
$0
$&
$0
&-
,
&'
$% %,
$% $'
%,
$)
$%
%$
&(,/,1*+(,*+7
6((3/$1)25$&78$/+(,*+76
;;
;
/(*(1'
/,*+7),;785(5()(572(/(&75,&$/3/$160(&+$1,&$/(48,30(175()(5720(&+$1,&$/3/$16 ,17(5,25 *<3680%2$5'&(,/,1*29(51(:;)5$0,1*,17(5,25 $&2867,&&(,/,1*7,/(5(86(250$7&+(;,67,1*7,/($1'*5,' &(,/,1*$&&(663$1(/'(02/,6+('2%-(&76
0$7(5,$/7$*5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21 '(02 ,17(5,25 *<3680%2$5'&(,/,1*6((.(<127('(02 ,17(5,25 $&2867,&$/&(,/,1*7,/(6((.(<127( (;7(5,25
(
62)),7725(0$,1
$&7
$&7
*:%
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(02/,7,215()/(&7('&(,/,1*3/$1 ),567)/225
$'
-+
-5

-5
$' 6&$/(
 

 '(02/,7,215()/(&7('&(,/,1*3/$1 ),567)/225
.(<127(6
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21 5()(5720(&+$1,&$/3/$16)25)857+(5,1)250$7,21 5()(572'(7$,/6)25)/225&(,/,1*$66(0%/,(6 +(,*+72)&(,/,1*66+$//%(0($685(')5207232)6/$%72),1,6+ )$&(2)*:%25)$&(2)&(,/,1**5,'$6,1',&$7('217+(5()/(&7('&(,/,1*3/$1812  %25'(56$7/$<,1$&2867,&$/&(,/,1*3$1(/66+$//%(&87720$7&+ )$&725<('*(352),/(12(;326(')$67(1(566+$//%(3(50,77(',1&/8',1*3235,9(76$1'7$33(76  &2175$&725729(5,)<'(37+2)62)),76$1'+2/'7,*+772 3/80%,1*635,1./(56(/(&75,&$/$1'0(&+$1,&$/'8&76
 6((0(&+$1,&$/'5$:,1*6)250(&+$&&(663$1(/63$,17720$7&+ &(,/,1*

 $7'5233('*:%62)),76*:%%($063529,'(&678'6$69(57,&$/ 68332576$7($&+6,'(2)7+(62)),7%($0$1'',$*21$/%5$&,1*)25:5$&.,1*,)&(,/,1*-2,6763$&,1*',))(56)520)/2257+(1%/2&.,1*%(7:((17+()/225)5$0,1*0$<%(87,/,=('72$77$&+7+(9(57,&$/675876 5&3*(1(5$/127(6
 $///,*+7),;785(6$5(72%(,167$//('$&&25',1*727+( $5&+,7(&785$/5()/(&7('&(,/,1*3/$1$5&+,7(&7725(9,(:&(,/,1*/$<287,1&/8',1*%8/.+($'6$1'*5,'35,2572,167$//$7,21  3529,'(1(:52//(56+$'(6$7$//(;7(5,25:,1'2:6(;&/8',1* (175$1&(9(67,%8/($1'6287+67$,56,1*/(52//(5:)$6&,$5()(57263(&6)256+$'(&/27+ $+ (;,67,1*&2/801725(0$,13527(&7,13/$&(%+ (;,67,1*62)),7'523725(0$,1%, (;,67,1*/,*+7),;785(72%(5(/2&$7('5()(572 (/(&75,&$/
$% 3$57,$//<5(029(*5,'$1'7,/($61(('(')251(::$// ,167$//$7,216(7$6,'(*5,'$1'7,/()25327(17,$/5(86( $& '(02/,6+*5,'5(029($1'6(7$6,'(7,/()25327(17,$/ 5(686(
$' 3$57,$//<5(029(62)),7$61(('(')251(::$// ,167$//$7,21
$) 02',)<62)),7$61(('(')25352326('62)),7(;7(16,21$0 (;,67,1*/,*+7),;785(72%(5(029('$1'',6&$5('(' 5()(572(/(&75,&$/
%$ 3$57,$//<5(029(*5,'$1'7,/($61(('(')255(&(66(' 352-(&7,216&5((1,167$//$7,216(7$6,'(*5,'$1'7,/()25327(17,$/5(86( &' (;,67,1*',))86(572%(5(029('$1'',6&$5'('5()(572 0(&+$1,&$/
&- (;,67,1*6725()521772%(5(029('$1'',6&$5'(', (;,67,1*:$//72%(5(029(' &

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 242 of 1531 ends



$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

$'0,1
$
'(37
&+,()

&+,()
&
67$,56

,17
$))$,56
/,(87

%5($.
5220

%26
0$1$*(5

38%/,&
$))$,56
0$1$*(5

%5($.
5220

6(59(5

:20(16

0(16

0((7,1*
5220

(/(9$725

&23<
5220

(/(90(&+

'(37
&+,()

&5,0(
$1$/<67


75$,1+,5,1*
0$1$*(5

(48,3

6)
&21)

+$//


$+
$&
$0$0
$%
$%
%, &'
$%
$%
$+ &'
&'&'
%$
$%
$+
&(,/,1*+(,*+7
6((3/$1)25$&78$/+(,*+76
;;
;
/(*(1'
/,*+7),;785(5()(572(/(&75,&$/3/$160(&+$1,&$/(48,30(175()(5720(&+$1,&$/3/$16 ,17(5,25 *<3680%2$5'&(,/,1*29(51(:;)5$0,1*,17(5,25 $&2867,&&(,/,1*7,/(5(86(250$7&+(;,67,1*7,/($1'*5,' &(,/,1*$&&(663$1(/'(02/,6+('2%-(&76
0$7(5,$/7$*5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21 '(02 ,17(5,25 *<3680%2$5'&(,/,1*6((.(<127('(02 ,17(5,25 $&2867,&$/&(,/,1*7,/(6((.(<127( (;7(5,25
(
62)),7725(0$,1
$&7
$&7
*:%
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(02/,7,215()/(&7('&(,/,1*3/$1 6(&21')/225
$'
-+
-5

-5
$' 6&$/(
 

 '(02/,7,215()/(&7('&(,/,1*3/$1 6(&21')/225
.(<127(6
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21 5()(5720(&+$1,&$/3/$16)25)857+(5,1)250$7,21 5()(572'(7$,/6)25)/225&(,/,1*$66(0%/,(6 +(,*+72)&(,/,1*66+$//%(0($685(')5207232)6/$%72),1,6+ )$&(2)*:%25)$&(2)&(,/,1**5,'$6,1',&$7('217+(5()/(&7('&(,/,1*3/$1812  %25'(56$7/$<,1$&2867,&$/&(,/,1*3$1(/66+$//%(&87720$7&+ )$&725<('*(352),/(12(;326(')$67(1(566+$//%(3(50,77(',1&/8',1*3235,9(76$1'7$33(76  &2175$&725729(5,)<'(37+2)62)),76$1'+2/'7,*+772 3/80%,1*635,1./(56(/(&75,&$/$1'0(&+$1,&$/'8&76
 6((0(&+$1,&$/'5$:,1*6)250(&+$&&(663$1(/63$,17720$7&+ &(,/,1*

 $7'5233('*:%62)),76*:%%($063529,'(&678'6$69(57,&$/ 68332576$7($&+6,'(2)7+(62)),7%($0$1'',$*21$/%5$&,1*)25:5$&.,1*,)&(,/,1*-2,6763$&,1*',))(56)520)/2257+(1%/2&.,1*%(7:((17+()/225)5$0,1*0$<%(87,/,=('72$77$&+7+(9(57,&$/675876 5&3*(1(5$/127(6
 $///,*+7),;785(6$5(72%(,167$//('$&&25',1*727+( $5&+,7(&785$/5()/(&7('&(,/,1*3/$1$5&+,7(&7725(9,(:&(,/,1*/$<287,1&/8',1*%8/.+($'6$1'*5,'35,2572,167$//$7,21  3529,'(1(:52//(56+$'(6$7$//(;7(5,25:,1'2:6(;&/8',1* (175$1&(9(67,%8/($1'6287+67$,56,1*/(52//(5:)$6&,$5()(57263(&6)256+$'(&/27+ $+ (;,67,1*&2/801725(0$,13527(&7,13/$&(%, (;,67,1*/,*+7),;785(72%(5(/2&$7('5()(572 (/(&75,&$/
$% 3$57,$//<5(029(*5,'$1'7,/($61(('(')251(::$// ,167$//$7,216(7$6,'(*5,'$1'7,/()25327(17,$/5(86( $& '(02/,6+*5,'5(029($1'6(7$6,'(7,/()25327(17,$/ 5(686(
$+ 02',)<(;,67,1*$&7&(,/,1*$61(('(')255(029$/2) 5(&(66('352-(&7256&5((1
$0 (;,67,1*/,*+7),;785(72%(5(029('$1'',6&$5('(' 5()(572(/(&75,&$/
%$ 3$57,$//<5(029(*5,'$1'7,/($61(('(')255(&(66(' 352-(&7,216&5((1,167$//$7,216(7$6,'(*5,'$1'7,/()25327(17,$/5(86( &' (;,67,1*',))86(572%(5(029('$1'',6&$5'('5()(572 0(&+$1,&$/
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 243 of 1531 ends

3)
(;,67,1*678')5$0(':$//725(0$,1
:$//7<3(6/(*(1'
$$$ (;,67,1*:$//)855,1*725(0$,1$ (;,67,1*0$6215<%/2&.:$//725(0$,1$ (;,67,1*&21&5(7(:$//725(0$,1$ (;,67,1*6725()5217:$//725(0$,1 1(:67((/678')5$0(',17(5,253$57,7,21:*<3%2$5'($&+6,'($&2867,&%$77,168/$7,216(($ )25'(7$,/6
$ (;,67,1*0$6215<%/2&.:$//725(0$,1

$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

%85($8
6(5*($17

0((7,1*

2)),&(

'521((48,3
6725$*(

'(7(&7,9(
(48,30(17

(/(&75,&$/

:20(1


0(1

+$//

-$1

+$//

6725$*(

67$,5

67$,5

%5,(),1*
5220

+$//


/2%%<

(/(9

6+$5('
2)),&(

$$
$
$ $
$$
$
$
$
$
$
$

$
%
%
%
%
$
$ $
$
$

6 6 6 6 6
$

$

$

$

$

%
6725$*(

: $
$
11
(
6
:
6
(
$
6 6
%
23(1
2)),&(

,1&,'(17
&20

%5($.
5220

$
$ 
$ 
6



$/,*1


$/,*1
$/,*1


$

$


$
9,)


9,)


9,)


9,)


9,)


9,)


9,)


9,)


9,)


9,)






($
(




$
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
352326('),567)/2253/$1
$
-+
-5

-5
.(<127(6
$ (;,67,1*6725()5217725(0$,13527(&7,13/$&($ $/80,1806725()52176<67(05()(5726&+('8/(6( :;'3(5621$/6725$*(/2&.(5% :$//02817('79%<2:1(5  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 )/2253/$1*(1(5$/127(6
 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21,)3529,'(' 5()(5720(&+$1,&$/3/$16'5$:,1*6255(32576 )25)857+(5 ,1)250$7,21
 5()(5723/80%,1*3/$1625'5$:,1*6)25 )857+(5,1)250$7,21,) 3529,'('
 12786(' ',0(16,216$5(72)$&(2)(;,67,1*),1,6+81/(6663(&,),&$//< 127('27+(5:,6(
 3529,'($'(48$7(%/2&.,1*,1:$//6)25&$%,1(76$1'27+(5:$// 02817('$&&(6625,(6,1&/8',1*%87127/,0,7('72+$1'5$,/66+(/9,1*$1'%$7+5220),;785(6  3529,'(),5(%/2&.,1*)25:$//&$9,7,(67+$7(;&(('&%& +(,*+7/,0,7$7,216

 '225$1':,1'2:',0(16,216$5(&(17(5('$723(1,1*6 :+(5('225,6/2&$7(':,7+287',0(16,21$77+(&251(52)$ 5220,76+$//%()520)$&(2))5$0,1*2)$'-$&(17:$//72528*+'22523(1,1*  6((&2'($1$/<6,6)25/2&$7,2162)),5(3$57,7,216$1'),5( %$55,(56
 :+(5(5(&(66('),;785(62&&85,1:$//625+25,=217$/ $66(0%/,(67+(),5(5$7,1*2)7+26($66(0%/,(66+$//%(0$,17$,1('  $7$//3(1(75$7,216$1',17(56(&7,2162)),5(5$7('3$57,7,216 3529,'(),5(6($/$17$1'25),5(67233,1*720$,17$,1&217,18,7<2)3$57,7,215$7,1* $ 6&$/(
 

 ),567)/2253/$1

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 244 of 1531 ends

83 83
(;,67,1*678')5$0(':$//725(0$,1
:$//7<3(6/(*(1'
$$$ (;,67,1*:$//)855,1*725(0$,1$ (;,67,1*0$6215<%/2&.:$//725(0$,1$ (;,67,1*&21&5(7(:$//725(0$,1$ (;,67,1*6725()5217:$//725(0$,1 1(:67((/678')5$0(',17(5,253$57,7,21:*<3%2$5'($&+6,'($&2867,&%$77,168/$7,216(($ )25'(7$,/6
$ (;,67,1*0$6215<%/2&.:$//725(0$,1

$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

%5($.
5220

6(59(5

:20(16

0(16 0((7,1* 

5220

(/(9$725

&23<
5220

(/(90(&+

'(37
&+,()

&5,0(
$1$/<67


75$,1+,5,1*
0$1$*(5

(48,3

$'0,1
$
'(37
&+,()

,17
$))$,56
/,(87

%5($.
5220

%26
0$1$*(5

38%/,&
$))$,56
0$1$*(5

+$//


-$1

&21)

67$,56

67$,56

-$1

&+,()
&
$
$ $
$
$


$
%
%
%
%
%

: $ (
1
6
(




$
0$7&+(;&2/801:,'7+ 0$7&+(;&2/801:,'7+
%


(4 (4(4 (4
$+
$
$


$
(
&



&
/
5 







$


&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
352326('6(&21')/2253/$1
$
-+
-5

-5
.(<127(6
$+ (;,67,1*&2/801725(0$,13527(&7,13/$&(& 6(0,5(&(66('),5((;7,1*8,6+(5&$%,1(7:,7+ (;7,1*8,6+(5$
%
&5$7,1*
5()(572$

( 3529,'(1(:),5((;7,1*8,6+(5&$%,1(7$1'),5( (;7,1*8,6+(5$7(;,67,1*/2&$7,21
% 32:(5('5(75$&7$%/(352-(&7,216&5((1%<2:1(5 &225',1$7(32&.(7,167$//$7,21:,7+&(,/,1*
% :$//02817('79%<2:1(5
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 )/2253/$1*(1(5$/127(6
 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21,)3529,'(' 5()(5720(&+$1,&$/3/$16'5$:,1*6255(32576 )25)857+(5 ,1)250$7,21
 5()(5723/80%,1*3/$1625'5$:,1*6)25 )857+(5,1)250$7,21,) 3529,'('
 12786(' ',0(16,216$5(72)$&(2)(;,67,1*),1,6+81/(6663(&,),&$//< 127('27+(5:,6(
 3529,'($'(48$7(%/2&.,1*,1:$//6)25&$%,1(76$1'27+(5:$// 02817('$&&(6625,(6,1&/8',1*%87127/,0,7('72+$1'5$,/66+(/9,1*$1'%$7+5220),;785(6  3529,'(),5(%/2&.,1*)25:$//&$9,7,(67+$7(;&(('&%& +(,*+7/,0,7$7,216

 '225$1':,1'2:',0(16,216$5(&(17(5('$723(1,1*6 :+(5('225,6/2&$7(':,7+287',0(16,21$77+(&251(52)$ 5220,76+$//%()520)$&(2))5$0,1*2)$'-$&(17:$//72528*+'22523(1,1*  6((&2'($1$/<6,6)25/2&$7,2162)),5(3$57,7,216$1'),5( %$55,(56
 :+(5(5(&(66('),;785(62&&85,1:$//625+25,=217$/ $66(0%/,(67+(),5(5$7,1*2)7+26($66(0%/,(66+$//%(0$,17$,1('  $7$//3(1(75$7,216$1',17(56(&7,2162)),5(5$7('3$57,7,216 3529,'(),5(6($/$17$1'25),5(67233,1*720$,17$,1&217,18,7<2)3$57,7,215$7,1* $ 6&$/(
 

 6(&21')/2253/$1

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 245 of 1531 ends

;;
; &(,/,1*+(,*+7
6((3/$1)25$&78$/+(,*+76

/(*(1'
/,*+7),;785(5()(572(/(&75,&$/3/$160(&+$1,&$/(48,30(175()(5720(&+$1,&$/3/$16 ,17(5,25 *<3680%2$5'&(,/,1*29(51(:;)5$0,1*,17(5,25 $&2867,&&(,/,1*7,/(5(86(250$7&+(;,67,1*7,/($1'*5,' &(,/,1*$&&(663$1(/'(02/,6+('2%-(&76
0$7(5,$/7$*5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21 '(02 ,17(5,25 *<3680%2$5'&(,/,1*6((.(<127('(02 ,17(5,25 $&2867,&$/&(,/,1*7,/(6((.(<127((;7(5,25 (
62)),7725(0$,1
$&7
$&7
*:%

$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &


&
&

$

+

$


'
%-
%-




0((7,1*

2)),&(

%85($8
6(5*($17

'521((48,3
6725$*(

'(7(&7,9(
(48,30(17

(/(&75,&$/

:20(1


0(1

+$//

-$1

+$//

6725$*(

67$,5

67$,5

%5,(),1*
5220

+$//


/2%%<

(/(9

6+$5('
2)),&(

6725$*(

23(1
2)),&(

,1&,'(17
&20

%5($.
5220


 


'
%+
$
$
$
$

+




)
)
9,)

'
(4 (4
(4 (4
(4 (4 (4 (4
%
(4 (4

+


 


+

$

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
5()/(&7('&(,/,1*3/$1 ),567)/225
$
-+
-5

-5
.(<127(6
%+ (;,67,1*62)),7'523725(0$,1%- (;,67,1*%8/.+($'725(0$,1 & *<3680%2$5'&(,/,1*$66(0%/<
' *<3680%2$5'62)),7 )5$0,1*
+ 1(:,17(5,25:$//72',(,172%277202)62)),75(3$,5 62)),7$5281'1(::$//$65(48,('

$ $&2867,&$//$<,17,/(&(,/,1*
+ $&2867,&$/&(,/,1*7,/( *5,'720$7&+(;,67,1*255(86( *22'&21',7,216(7$6,'((;,67,1*7,/($1'*5,'
% 32:(5('5(75$&7$%/(352-(&7,216&5((1%<2:1(5 &225',1$7(32&.(7,167$//$7,21:,7+&(,/,1*
) (;+$867)$15()(5720(&+$1,&$/$ 1(:,//80,1$7('(;,76,*1$ /,*+7),;785(5()(572(/(&75,&$/  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21 5()(5720(&+$1,&$/3/$16)25)857+(5,1)250$7,21 5()(572'(7$,/6)25)/225&(,/,1*$66(0%/,(6 +(,*+72)&(,/,1*66+$//%(0($685(')5207232)6/$%72),1,6+ )$&(2)*:%25)$&(2)&(,/,1**5,'$6,1',&$7('217+(5()/(&7('&(,/,1*3/$1812  %25'(56$7/$<,1$&2867,&$/&(,/,1*3$1(/66+$//%(&87720$7&+ )$&725<('*(352),/(12(;326(')$67(1(566+$//%(3(50,77(',1&/8',1*3235,9(76$1'7$33(76  &2175$&725729(5,)<'(37+2)62)),76$1'+2/'7,*+772 3/80%,1*635,1./(56(/(&75,&$/$1'0(&+$1,&$/'8&76
 6((0(&+$1,&$/'5$:,1*6)250(&+$&&(663$1(/63$,17720$7&+ &(,/,1*

 $7'5233('*:%62)),76*:%%($063529,'(&678'6$69(57,&$/ 68332576$7($&+6,'(2)7+(62)),7%($0$1'',$*21$/%5$&,1*)25:5$&.,1*,)&(,/,1*-2,6763$&,1*',))(56)520)/2257+(1%/2&.,1*%(7:((17+()/225)5$0,1*0$<%(87,/,=('72$77$&+7+(9(57,&$/675876 5&3*(1(5$/127(6
 $///,*+7),;785(6$5(72%(,167$//('$&&25',1*727+( $5&+,7(&785$/5()/(&7('&(,/,1*3/$1$5&+,7(&7725(9,(:&(,/,1*/$<287,1&/8',1*%8/.+($'6$1'*5,'35,2572,167$//$7,21  3529,'(1(:52//(56+$'(6$7$//(;7(5,25:,1'2:6(;&/8',1* (175$1&(9(67,%8/($1'6287+67$,56,1*/(52//(5:)$6&,$5()(57263(&6)256+$'(&/27+ $ 6&$/(
 

 5()/(&7('&(,/,1*3/$1 ),567)/225

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 246 of 1531 ends

;;
; &(,/,1*+(,*+7
6((3/$1)25$&78$/+(,*+76

/(*(1'
/,*+7),;785(5()(572(/(&75,&$/3/$160(&+$1,&$/(48,30(175()(5720(&+$1,&$/3/$16 ,17(5,25 *<3680%2$5'&(,/,1*29(51(:;)5$0,1*,17(5,25 $&2867,&&(,/,1*7,/(5(86(250$7&+(;,67,1*7,/($1'*5,' &(,/,1*$&&(663$1(/'(02/,6+('2%-(&76
0$7(5,$/7$*5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21 '(02 ,17(5,25 *<3680%2$5'&(,/,1*6((.(<127('(02 ,17(5,25 $&2867,&$/&(,/,1*7,/(6((.(<127( (;7(5,25
(
62)),7725(0$,1
$&7
$&7
*:%

$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

$'0,1
$
'(37
&+,()

&+,()
&
67$,56

,17
$))$,56
/,(87

%5($.
5220

%26
0$1$*(5

38%/,&
$))$,56
0$1$*(5

%5($.
5220

6(59(5

:20(16

0(16


0((7,1*
5220

(/(9$725

&23<
5220

(/(90(&+

'(37
&+,()

&5,0(
$1$/<67


75$,1+,5,1*
0$1$*(5

(48,3

6)
&21)

+$//



+
+

+
)

+
$

+

+
$
)
$




)
$
%
(4 (4(4 (4
(4 (4
(4 (4

 (4
(4 
 (4

 (4

+

+

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
5()/(&7('&(,/,1*3/$1 6(&21')/225
$
-+
-5

-5
.(<127(6

+ $&2867,&$/&(,/,1*7,/( *5,'720$7&+(;,67,1*255(86( *22'&21',7,216(7$6,'((;,67,1*7,/($1'*5,'
% 32:(5('5(75$&7$%/(352-(&7,216&5((1%<2:1(5 &225',1$7(32&.(7,167$//$7,21:,7+&(,/,1*
$ 0(&+$1,&$/(48,30(175()(5720(&+$1,&$/) (;+$867)$15()(5720(&+$1,&$/$ /,*+7),;785(5()(572(/(&75,&$/) 1(:/2&$7,212)/,*+7),;785(5()(572(/(&75,&$/  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21 5()(5720(&+$1,&$/3/$16)25)857+(5,1)250$7,21 5()(572'(7$,/6)25)/225&(,/,1*$66(0%/,(6 +(,*+72)&(,/,1*66+$//%(0($685(')5207232)6/$%72),1,6+ )$&(2)*:%25)$&(2)&(,/,1**5,'$6,1',&$7('217+(5()/(&7('&(,/,1*3/$1812  %25'(56$7/$<,1$&2867,&$/&(,/,1*3$1(/66+$//%(&87720$7&+ )$&725<('*(352),/(12(;326(')$67(1(566+$//%(3(50,77(',1&/8',1*3235,9(76$1'7$33(76  &2175$&725729(5,)<'(37+2)62)),76$1'+2/'7,*+772 3/80%,1*635,1./(56(/(&75,&$/$1'0(&+$1,&$/'8&76
 6((0(&+$1,&$/'5$:,1*6)250(&+$&&(663$1(/63$,17720$7&+ &(,/,1*

 $7'5233('*:%62)),76*:%%($063529,'(&678'6$69(57,&$/ 68332576$7($&+6,'(2)7+(62)),7%($0$1'',$*21$/%5$&,1*)25:5$&.,1*,)&(,/,1*-2,6763$&,1*',))(56)520)/2257+(1%/2&.,1*%(7:((17+()/225)5$0,1*0$<%(87,/,=('72$77$&+7+(9(57,&$/675876 5&3*(1(5$/127(6
 $///,*+7),;785(6$5(72%(,167$//('$&&25',1*727+( $5&+,7(&785$/5()/(&7('&(,/,1*3/$1$5&+,7(&7725(9,(:&(,/,1*/$<287,1&/8',1*%8/.+($'6$1'*5,'35,2572,167$//$7,21  3529,'(1(:52//(56+$'(6$7$//(;7(5,25:,1'2:6(;&/8',1* (175$1&(9(67,%8/($1'6287+67$,56,1*/(52//(5:)$6&,$5()(57263(&6)256+$'(&/27+ $ 6&$/(
 

 5()/(&7('&(,/,1*3/$1 6(&21')/225
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 247 of 1531 ends

/(*(1'

(
'(&.
(
6,1*/(3/<522),1*6<67(0


$ $% %
* *
    

( (
' '
 
 
 
  
) )

& &

(
(
)
7<3
$(
7<3
$&
7<3
$&
$
$(

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
522)3/$1
$
-+
-5

-5
.(<127(6
$& (;,67,1*/2:6/23(6,1*/(3/<522)725(0$,1$( (;,67,1*3$5$3(7&$3725(0$,1( (;,67,1*0(&+$1,&$/81,7725(0$,1) (;,67,1*522)+$7&+725(0$,1$ 0(&+$1,&$/(48,30(175()(5720(&+$1,&$/  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(5720(&+$1,&$/3/$16)25522)02817('(48,30(17 /2&$7,216$1'7<3(6
 5()(572(/(&75,&$/3/$16)2532:(5',675,%87,2172522) 02817('(48,30(17
 $//522),1*0$7(5,$/672%(,167$//('3(50$18)$&785(5 6
63(&,),&$7,216
522)3/$1*(1(5$/127(6
$ 6&$/(
 

 522)3/$1
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 248 of 1531 ends

 
  
/
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

(;7(5,25(/(9$7,216
$
-+
-5

-5
/ (;,67,1*,//80,1$7('6,*1$*(&$%,1(7725(0$,11(:
$57:25.3529,'('%<2:1(581'(56(3$5$7(3(50,7
$ $ 6&$/(
 

 :(67(/(9$7,21
.(<127(6

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 249 of 1531 ends

7<3
4
$
:20(16

0(16


$ (
$
6
1
: (
:
1
6
0,1&/5
0,1&/5
(



0 1
,

&
/
5 
$
;
&/5
;
&/5
%
%%
%
) ;
&/5
)
)
&
&
&
-$1




0 1
,&
/
5 5
7<3
5
 





*
7






 




4
76+$3('7851,1*63$&(3(5%.1((&/($5$1&(3529,'('$7 $&&(66,%/(/$9
&
%
7<3
4
&
4 $
7<3
$
9 ,
)







9 ,
)






9,)


*
9,)







&
/
5 : $
$
11
(
6
:
6
(
0(1

:20(1


7<3
4
;
&/5
;
&/5
7<3
4
%%

[
&/5

[
&/5
&
)
&
)
'2256:,1*$//2:('72(1&52$&+21&/($5)/22563$&(3(5% 
4*
5
&
/
5 


&
/
5 


4 5*

0(1

:20(1


$
8
&0&0
$%
&&
8
$ $
&&
$
$
%
$%%
8
7<3
&0
8
$
$
$
7<3
&0
7<3
&&
7<3
&&
+
(
&%
$
7<3
%
'(02(;,67,1*3$57,7,2125:$//),1,6+'(02 ,17(5,25 7,/( 127(
5()(572,17(5,25),1,6+6&+('8/(6216+((76$ $)25$''7,21$/,1)250$7,21 &

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
(1/$5*(')/2253/$16
$
-+
-5

-5
.(<127(6
$ (;,67,1*3/80%,1*),;785(72%(5(029('% (;,67,1*72,/(73$57,7,2172%(5(029('&% (;,67,1*,17(5,25:$//72%(5(029('3527(&7,13/$&( (;,67,1*$'-$&(17:$//3$7&+:$//*$3$)7(5'(02/,7,212)(;,6,71*:$// && (;,67,1*:$//7,/(72%(5(029('35(3$5(:$//685)$&( )251(:7,/(),1,6+7<32)$//5(675220:$//6
&0 (;,67,1**5$%%$572%(5(029('( (;,67,1*'225$1')5$0(72%(5(029('+ (;,67,1*'22572%(5(029(')/,3'2256:,1*',5(&7,21 $1'5(,167$//
8 (;,67,1*7,/()/22572%(5(029('35(3$5(
(
6/$%)25
1(:7,/(),1,6+(6
$ 72,/(7&203$570(17% 85,1$/6&5((1& 6(/)&/26,1*'225$7$&&(66,%/(72,/(767$//% 685)$&(02817('72,/(73$3(5',63(16(5& 62$3',63(16(5) 0,5525* 6(0,5(&(66('3$3(572:(/',63(16(54 *5$%%$54 6,1.25/$9$725<5()(5723/80%,1*5 72,/(75()(5723/80%,1*7 85,1$/5()(5723/80%,1*  5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 )/2253/$1*(1(5$/127(6
 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21,)3529,'(' 5()(5720(&+$1,&$/3/$16'5$:,1*6255(32576 )25)857+(5 ,1)250$7,21
 5()(5723/80%,1*3/$1625'5$:,1*6)25 )857+(5,1)250$7,21,) 3529,'('
 12786(' ',0(16,216$5(72)$&(2)(;,67,1*),1,6+81/(6663(&,),&$//< 127('27+(5:,6(
 3529,'($'(48$7(%/2&.,1*,1:$//6)25&$%,1(76$1'27+(5:$// 02817('$&&(6625,(6,1&/8',1*%87127/,0,7('72+$1'5$,/66+(/9,1*$1'%$7+5220),;785(6  3529,'(),5(%/2&.,1*)25:$//&$9,7,(67+$7(;&(('&%& +(,*+7/,0,7$7,216

 '225$1':,1'2:',0(16,216$5(&(17(5('$723(1,1*6 :+(5('225,6/2&$7(':,7+287',0(16,21$77+(&251(52)$ 5220,76+$//%()520)$&(2))5$0,1*2)$'-$&(17:$//72528*+'22523(1,1*  6((&2'($1$/<6,6)25/2&$7,2162)),5(3$57,7,216$1'),5( %$55,(56
 :+(5(5(&(66('),;785(62&&85,1:$//625+25,=217$/ $66(0%/,(67+(),5(5$7,1*2)7+26($66(0%/,(66+$//%(0$,17$,1('  $7$//3(1(75$7,216$1',17(56(&7,2162)),5(5$7('3$57,7,216 3529,'(),5(6($/$17$1'25),5(67233,1*720$,17$,1&217,18,7<2)3$57,7,215$7,1* $ $ 6&$/(
 

 1')/2255(675220 352326('
)/2250$7(5,$/6/(*(1'
$ $ 6&$/(
 

 ),567)/2255(675220 352326('
$' $ 6&$/(
 

 ),567)/2255(675220 '(02
$' $ 6&$/(
 

 6(&21')/2255(675220 '(02

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 250 of 1531 ends


$


















































































































































/97 0$7(5,$/7$*
5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21
127(
5()(572,17(5,25),1,6+6&+('8/(6216+((76
$ $)25$''7,21$/,1)250$7,21
:  '
+
$5&+,7(&785$/:22':25.
67$1'$5'&$%,1(7'(6,*16(5,(6180%(5
237'(6,*102'
'(6&5,37,21
' '(37+: :,'7++ +(,*+7
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

,17(5,25(/(9$7,216
$
-+
-5

-5
 
  0(165(675220 ),567)/225
1 ( 6 : (
 
 
 :20(165(675220 ),567)/225
1 6 :
 
 
 0(165(675220 6(&21')/225
1 ( 6 :
 
  :20(165(675220 6(&21')/225
1 ( 6 :

$ &(5$0,&7,/(:$//$33/,&$7,21
.(<127(6
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,2121(/(&75,&$/ (48,30(17
 5()(5725&3
6)2562)),7',0(16,216$1')857+(5,1)250$7,21 3529,'(%/2&.,1*)25$//:$//6:+(5(:$//+81*(48,30(17$1' ),;785(62&&85
 $//',0(16,2166+2:1,1$522072%(&216,'(5('7<3,&$/)25($&+ (/(9$7,212)7+(522081/(66127('27+(5:,6(
 9(5,)<02817,1*+(,*+762)$&&(6625,(6$1'3/80%,1*),;785(6 0((7$&&(66,%,/,7<5(48,5(0(176:+(5($33/,&$%/(
 $//:$//$1'&(,/,1*),1,6+(66+$//&203/<:,7+&%&7$%/(  )250$;,080)/$0(635($'$1'602.('(16,7<
,17(/(96*(1(5$/127(6 /(*(1' 
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 251 of 1531 ends


$

6



7<3
4
%$
/97 0$7(5,$/7$*
5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21
127(
5()(572,17(5,25),1,6+6&+('8/(6216+((76
$ $)25$''7,21$/,1)250$7,21
:  '
+
$5&+,7(&785$/:22':25.
67$1'$5'&$%,1(7'(6,*16(5,(6180%(5
237'(6,*102'
'(6&5,37,21
' '(37+: :,'7++ +(,*+7
4
6 6 6 6 6





6 6
$ %
%$ $
$
%
%.
'
$ % $
'
%
6
$
6
6 6 6 6 6

$
'
$
2
$

 233





7:7%&29(%$6(,16,'(&251(572,16,'(&251(5$7'5,1.,1*)2817$,1$/&29( &

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

,17(5,25(/(9$7,216
$
-+
-5

 
  23(12)),&( 352326(' -5

 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,2121(/(&75,&$/ (48,30(17
 5()(5725&3
6)2562)),7',0(16,216$1')857+(5,1)250$7,21 3529,'(%/2&.,1*)25$//:$//6:+(5(:$//+81*(48,30(17$1' ),;785(62&&85
 $//',0(16,2166+2:1,1$522072%(&216,'(5('7<3,&$/)25($&+ (/(9$7,212)7+(522081/(66127('27+(5:,6(
 9(5,)<02817,1*+(,*+762)$&&(6625,(6$1'3/80%,1*),;785(6 0((7$&&(66,%,/,7<5(48,5(0(176:+(5($33/,&$%/(
 $//:$//$1'&(,/,1*),1,6+(66+$//&203/<:,7+&%&7$%/(  )250$;,080)/$0(635($'$1'602.('(16,7<
 5()(572),1,6+6&+('8/(21$)25:$//),1,6+0$7(5,$/6$1' &2/256(/(&7,216

 7,/(6+28/'6723$77232)'225-$0%
,17(/(96*(1(5$/127(6
$ (;,67,1*6725()5217725(0$,13527(&7,13/$&(%. (;,67,1*35,9$&<),/0725(0$,14 3529,'(%/2&.,1*)25)8785(2:1(53529,'(' :$//02817('79%5$&.(7
$ $/80,1806725()52176<67(05()(5726&+('8/(6' )5267('*/$6635,9$&<6&5((1% 32:(5('5(75$&7$%/(352-(&7,216&5((1%<2:1(5 &225',1$7(32&.(7,167$//$7,21:,7+&(,/,1*
2 +,/2:'5,1.,1*)2817$,15()(5723/80%,1*$ &$%/('$7$32:(5&211(&7,215((/(&% :$//02817('79%<2:1(5 .(<127(6
 
  0((7,1*$5($

/(*(1'
 
  %5,(),1*5220
 



&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 252 of 1531 ends

9 
,
)








02',)<&$%,1(7723529,'(
$&&(66,%/(.,7&+(16,1.6(('(7$,/

$

9,)




















 


  

  

 


 
'



 
2
-

$



















 


  

 



 
2
-
'
'
/97 0$7(5,$/7$*
5()(5720$7(5,$/6&+('8/()25025(,1)250$7,21
127(
5()(572,17(5,25),1,6+6&+('8/(6216+((76
$ $)25$''7,21$/,1)250$7,21
:  '
+
$5&+,7(&785$/:22':25.
67$1'$5'&$%,1(7'(6,*16(5,(6180%(5
237'(6,*102'
'(6&5,37,21
' '(37+: :,'7++ +(,*+7
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
,17(5,25(/(9$7,216
$
-+
-5

-5

 
 %5($.50

 
 %5($.50
 
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,2121(/(&75,&$/ (48,30(17
 5()(5725&3
6)2562)),7',0(16,216$1')857+(5,1)250$7,21 3529,'(%/2&.,1*)25$//:$//6:+(5(:$//+81*(48,30(17$1' ),;785(62&&85
 $//',0(16,2166+2:1,1$522072%(&216,'(5('7<3,&$/)25($&+ (/(9$7,212)7+(522081/(66127('27+(5:,6(
 9(5,)<02817,1*+(,*+762)$&&(6625,(6$1'3/80%,1*),;785(6 0((7$&&(66,%,/,7<5(48,5(0(176:+(5($33/,&$%/(
 $//:$//$1'&(,/,1*),1,6+(66+$//&203/<:,7+&%&7$%/(  )250$;,080)/$0(635($'$1'602.('(16,7<
 5()(572),1,6+6&+('8/(21$)25:$//),1,6+0$7(5,$/6$1' &2/256(/(&7,216

 7,/(6+28/'6723$77232)'225-$0%
,17(/(96*(1(5$/127(6 .(<127(6 /(*(1'
- %$6(&$%,1(76:'5$:(56'2256 $'-867$%/(6+(/9,1*2 833(5&$%,1(7:'2256 $'-867$%/(6+(/9,1*' 5()5,*(5$725:,&(0$.(5 2:1(5)851,6+('$1'
,167$//('&225',1$7(,167$//$7,21:,7+2:1(5
' 3/$67,&/$0,1$7(&2817(5723 %$&.63/$6+

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 253 of 1531 ends

83 3)
(;,67,1*)/225,1*725(0$,1
),1,6+/(*(1'
1(:325&(/$,17,/()/2251(:/97)/2251(:&$53(77,/()/2251(::$/.2))0$7&$53(77,/( 67$,1/(6667((/&251(5*8$5')/225,1*,167$//',5(&7,21
6+$5('
2)),&(
%85($8
6(5*($17
6725$*(
67$,5
6)
/2%%<
(/(9
2)),&(
0((7,1*
%5,(),1*
5220
+$//
+$//
6)
67$,5
0(1
:20(1

6)
(/(&75,&$/
+$//-$1
'521((48,3
6725$*(
'(7(&7,9(
(48,30(17
,1&,'(17
&20 %5($.
5220
6725$*(
&37
&37
&37
&37
&37&37
&37
/97 /97
/97
/97
/97
/97
:20
:20
5%5
5%5
&37
3
7
777
33
3
7%
3
3 3
7%
23(1
2)),&(
3
3
%
%

(

(

(

$ * +
% %
$
%
$
%%
%
%%
56 56 56 56
56
56
5656
(
'
(
'

%
%
%
%
%
$ $
%%
$
$
.
.
*
7
7$&7,/((;,76,*15($',1*(;,7:+(5(02817('21*/$666,=((;,76,*1720$7&+(;7(5,25*/$6602817('5220,'(17,),&$,7216,*1$*($/,*1(;,76,*1:,7+52206,1*$*(:+(102817,1* 5220,'(17,),&$7,216,*1:+(5(02817('21*/$663529,'(6,=(0$7&+('%/$1.6,*1$*(3/$7(21%$&.6,'(2)*/$66,)1227+(56,1*$*(,63529,'('&217(177%'%<2:1(5

$
%
2&&83$17/2$'6,*17+$767$7(60$;,0802&&83$1&<3(56216 +
' *(20(75,&6<0%2/02817('21'225
( 5220,'(17,),&$7,21:,7+3,&72*5$0$1'
,17(51$7,21$/6<0%2/2)$&&(66,%,/,7<
,17(51$7,21$/6<0%2/2)$&&(66)25+($5,1*,03$,5(',1&/8'(:25',1*7+$767$7(6$66,67,9(/,67(1,1*6<67(0$9$,/$%/( *
6,*1725($'(;7(5,25$5($)25$66,67('5(6&8(6,*1$*(72&203/<:,7+&%& 

-
. 6,*1725($'3/($6(%($:$5(9,'(2021,725,1*,1352*5(66 
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

),567)/225),1,6+3/$1
$
-+
-5

-5
,17(5,25),1,6+6&+('8/(
$ 6&$/(
 

 ),567)/225),1,6+3/$1
$ $
,17(5,25:$//$1'&(,/,1*),1,6+5(48,5(0(176%<2&&83$1&<

&%&7$%/(

&/$66,),&$7,216
&/$66$
‡ )/$0(635($',1'(; ‡ 602.('(9(/23(',1'(; &/$66% ‡ )/$0(635($',1'(; ‡ 602.('(9(/23(',1'(; &/$66& ‡ )/$0(635($',1'(; ‡ 602.('(9(/23(',1'(;  $$$%(05555556
*5283 ,17(5,25(;,7
67$,5:$<6$1'
5$036$1'(;,7
3$66$*(:$<6
&255,'256$1'
(1&/2685()25(;,7
$&&(6667$,5:$<6
$1'5$036
52206$1'
(1&/26('63$&(6
%
%%&
%
&&&
%
%
&
&&&&&
&
&&
&&&&&
3(5 &%& ,17(5,25:$//$1'&(,/,1*),1,6+6+$//+$9($)/$0(635($',1'(;127*5($7(57+$17+$763(&,),(',17$%/()25 7+(*5283$1'/2&$7,21'(6,*1$7('5()(572 &%&6(& )25 $'',7,21$/,1)250$7,21
'(*5((2)),5(3527(&7,21
635,1./(5('
),1,6+5(48,5(0(176
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21 5()(5723/80%,1*3/$16)25)857+(5,1)250$7,21 5()(572'(7$,/6)25)/225&(,/,1*$66(0%/,(6$1',17(5,25),1,6+ '(7$,/6
 $//+$5'685)$&()/225,1*6+$//%(6/,35(6,67$17$1'0((77+( $16,$ 67$1'$5')250($685,1*7+('<1$0,&&2()),&,(172))5,&7,21 '&2)

 $//)/225,1*0$7(5,$/66+$//&203/<:,7+&%&6(& $//:$//$1'&(,/,1*),1,6+(66+$//&203/<:,7+&%&7$%/(  )250$;,080)/$0(635($'$1'602.('(16,7<
 3529,'(52//(56+$'(6$7$//(;7(5,25:,1'2:6$1'6725()5217 (;&(37$7'22566((63(&6
),1,6+3/$1*(1(5$/127(6
&6,6SHF6HFWLRQ 7$* '(6&5,37,21 /2&$7,21 0$18)$&785(5 352'8&763(& 6,=( ),1,6+&2/25 127(6

(
(;,67,1*),1,6+725(0$,1 6((3/$16
$5&+,7(&785$/:22':25.$5&+,7(&785$/:22':25. 3/ 3/$67,&/$0,1$7(&$%,1(76 %5($.5220 1(9$0$5 1$9<0$75,; 057


7,/,1*
7,/,1* 7 &(5$0,&)/225 :$//7,/( 5(6752206 '$/7,/( ',*1,7$5< ; 683(5,257$83( 7,/,1* 7 $&&(17&(5$0,&:$//7,/( 5(6752206 '$/7,/( 5(9$/,$5(0,; 5$',$17%/8()$1 $&&(17675,367$57,1*$7 7,/,1* 7% &(5$0,&7,/(&29(%$6( 5(6752206 '$/7,/( ',*1,7$5< ; 683(5,257$83( 5(6,/,(17)/225,1*
5(6,/,(17)/225,1*
% *(1(5$/%$6( *(1(5$/821 5233( 3,11$&/( +
52//
%/$&.



5(6,/,(17)/225,1*
/97 /8;85<9,1</7,/( %5($.5220(48,36725$*( 0,//,.(1 0(7523$5._3,.( [ $17/(5 $6+/$5,167$//$7,21 
5(6,/,(17)/225,1*
5%5 58%%(567$,575($'6 67$,56 5233( 5$,6('&,5&8/$59$17$*('(6,*1 :,7+5,6(5

&+$5&2$/



7,/(&$53(7,1*
7,/(&$53(7,1* &37 &$53(77,/( *(1(5$/&$53(77,/(821 6+$:&2175$&7 ',))86(',63(56(_',))86( (&2:25;
[ 0$*1(7,&),(/' 48$57(57851,167$//$7,21

7,/(&$53(7,1* :20 &$53(77,/( (;,76 6+$:&2175$&7 $//$&&(66_3$&(7,/( [ 67(3 0212/,7+,&,167$//$7,21 
,17(5,253$,17,1*

,17(5,253$,17,1*
3 *(1(5$/',1,1*3$,17 *(1(5$/821 6+(50,1:,//,$06 3$66,9( 6:
(**6+(//),1,6+


,17(5,253$,17,1*
3 $&&(173$,17 35,9$7(2)),&(63$,17(''2256$1'
+0'22575,0
6+(50,1:,//,$06 67$03('&21&5(7(
6:
(**6+(//),1,6+


,17(5,253$,17,1*
3 $&&(173$,17 6((3/$16 6+(50,1:,//,$06 ',67$1&(
6:
(**6+(//),1,6+


,17(5,253$,17,1*
3 $&&(173$,17 6((3/$16 6+(50,1:,//,$06 ,17+(1$9< 6:

(**6+(//),1,6+

3/$67,&72,/(7&203$570(176
3/$67,&72,/(7&203$570(176
73 &$53(77,/( 6(&21'/(9(/5(6752206 $6, 62/,'3/$67,& +'3(
3$57,7,216 &+$5&2$/


)/225$1&+25('29(5+($'%5$&('
:,1'2:6+$'(6:,1'2:6+$'(6 56 52//(56+$'( 6((3/$16 0(&+26+$'(6 0$18$/52//(56+$'(6:,7+ (&29(,/6&5((16
23(1

6,/9(5%,5&+ $''$/7725(3/$&($//:,1'2:6+$'(63(53/$1 &2817(57236&2817(57236 3/ 3/$67,&/$0,1$7(&2817(5 %5($.5220 )250,&$ 6($6($/7




6,*1$*(/(*(1'
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 254 of 1531 ends

83 83
3)
(;,67,1*)/225,1*725(0$,1
),1,6+/(*(1'
1(:325&(/$,17,/()/2251(:/97)/2251(:&$53(77,/()/2251(::$/.2))0$7&$53(77,/( 67$,1/(6667((/&251(5*8$5')/225,1*,167$//',5(&7,21
%5($.
5220
6(59(5
:20(16
0(16 0((7,1* 5220
(/(9$725

&23<
5220
(/(90(&+
'(37
&+,()
&5,0(
$1$/<67
75$,1+,5,1*
0$1$*(5
(48,3
$'0,1
'(37
&+,()
,17
$))$,56
/,(87
%5($.
5220
%26
0$1$*(5
38%/,&
$))$,56
0$1$*(5
+$//


-$1
&21)
67$,56

67$,56

-$1

&+,()
5%5
5%5
&37&37
&37
7
7
3
7%
7
7
7
7%
7
&37
&37
&37
&37 &37
&37 &37
/97
/97
/97
3
3
3
3
3
3
&37
+$//


(

&37&37

(

(

(

&37
3
3
3
3
33
33
3
*
% %
%%
%
%
%
%
% $
%
73
73
56 56 56
56 56 56 56
56
3/3/
'
(
' (
%
%
%
%
%
%
*
7$&7,/((;,76,*15($',1*(;,7:+(5(02817('21*/$666,=((;,76,*1720$7&+(;7(5,25*/$6602817('5220,'(17,),&$,7216,*1$*($/,*1(;,76,*1:,7+52206,1*$*(:+(102817,1* 5220,'(17,),&$7,216,*1:+(5(02817('21*/$663529,'(6,=(0$7&+('%/$1.6,*1$*(3/$7(21%$&.6,'(2)*/$66,)1227+(56,1*$*(,63529,'('&217(177%'%<2:1(5

$
%
2&&83$17/2$'6,*17+$767$7(60$;,0802&&83$1&<3(56216 +
' *(20(75,&6<0%2/02817('21'225
( 5220,'(17,),&$7,21:,7+3,&72*5$0$1'
,17(51$7,21$/6<0%2/2)$&&(66,%,/,7<
,17(51$7,21$/6<0%2/2)$&&(66)25+($5,1*,03$,5(',1&/8'(:25',1*7+$767$7(6$66,67,9(/,67(1,1*6<67(0$9$,/$%/( *
6,*1725($'(;7(5,25$5($)25$66,67('5(6&8(6,*1$*(72&203/<:,7+&%& 

-
. 6,*1725($'3/($6(%($:$5(9,'(2021,725,1*,1352*5(66 
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

6(&21')/225),1,6+3/$1
$
-+
-5

-5
5220),1,6+6&+('8/(
$ $
,17(5,25:$//$1'&(,/,1*),1,6+5(48,5(0(176%<2&&83$1&<

&%&7$%/(

&/$66,),&$7,216
&/$66$
‡ )/$0(635($',1'(; ‡ 602.('(9(/23(',1'(; &/$66% ‡ )/$0(635($',1'(; ‡ 602.('(9(/23(',1'(; &/$66& ‡ )/$0(635($',1'(; ‡ 602.('(9(/23(',1'(;  $$$%(05555556
*5283 ,17(5,25(;,7
67$,5:$<6$1'
5$036$1'(;,7
3$66$*(:$<6
&255,'256$1'
(1&/2685()25(;,7
$&&(6667$,5:$<6
$1'5$036
52206$1'
(1&/26('63$&(6
%
%%&
%
&&&
%
%
&
&&&&&
&
&&
&&&&&
3(5 &%& ,17(5,25:$//$1'&(,/,1*),1,6+6+$//+$9($)/$0( 635($',1'(;127*5($7(57+$17+$763(&,),(',17$%/()25 7+(*5283$1'/2&$7,21'(6,*1$7('5()(572 &%&6(& )25 $'',7,21$/,1)250$7,21
'(*5((2)),5(3527(&7,21
635,1./(5('
),1,6+5(48,5(0(176
 5()(572*(1(5$/127(66+((7*)25$'',7,21$/5(48,5(0(176 5()(572(/(&75,&$/3/$16)25)857+(5,1)250$7,21 5()(5723/80%,1*3/$16)25)857+(5,1)250$7,21 5()(572'(7$,/6)25)/225&(,/,1*$66(0%/,(6$1',17(5,25),1,6+ '(7$,/6
 $//+$5'685)$&()/225,1*6+$//%(6/,35(6,67$17$1'0((77+( $16,$ 67$1'$5')250($685,1*7+('<1$0,&&2()),&,(172))5,&7,21 '&2)

 $//)/225,1*0$7(5,$/66+$//&203/<:,7+&%&6(& $//:$//$1'&(,/,1*),1,6+(66+$//&203/<:,7+&%&7$%/(  )250$;,080)/$0(635($'$1'602.('(16,7<
 3529,'(52//(56+$'(6$7$//(;7(5,25:,1'2:6$1'6725()5217 (;&(37$7'22566((63(&6
),1,6+3/$1*(1(5$/127(6
$ 6&$/(
 

 6(&21')/225),1,6+3/$1
&6,6SHF6HFWLRQ 7$* '(6&5,37,21 /2&$7,21 0$18)$&785(5 352'8&763(& 6,=( ),1,6+&2/25 127(6

(
(;,67,1*),1,6+725(0$,1 6((3/$16
$5&+,7(&785$/:22':25.$5&+,7(&785$/:22':25. 3/ 3/$67,&/$0,1$7(&$%,1(76 %5($.5220 1(9$0$5 1$9<0$75,; 057


7,/,1*
7,/,1* 7 &(5$0,&)/225 :$//7,/( 5(6752206 '$/7,/( ',*1,7$5< ; 683(5,257$83( 7,/,1* 7 $&&(17&(5$0,&:$//7,/( 5(6752206 '$/7,/( 5(9$/,$5(0,; 5$',$17%/8()$1 $&&(17675,367$57,1*$7 7,/,1* 7% &(5$0,&7,/(&29(%$6( 5(6752206 '$/7,/( ',*1,7$5< ; 683(5,257$83( 5(6,/,(17)/225,1*
5(6,/,(17)/225,1*
% *(1(5$/%$6( *(1(5$/821 5233( 3,11$&/( +
52//
%/$&.



5(6,/,(17)/225,1*
/97 /8;85<9,1</7,/( %5($.5220(48,36725$*( 0,//,.(1 0(7523$5._3,.( [ $17/(5 $6+/$5,167$//$7,21 
5(6,/,(17)/225,1*
5%5 58%%(567$,575($'6 67$,56 5233( 5$,6('&,5&8/$59$17$*('(6,*1 :,7+5,6(5

&+$5&2$/



7,/(&$53(7,1*
7,/(&$53(7,1* &37 &$53(77,/( *(1(5$/&$53(77,/(821 6+$:&2175$&7 ',))86(',63(56(_',))86( (&2:25;
[ 0$*1(7,&),(/' 48$57(57851,167$//$7,21

7,/(&$53(7,1* :20 &$53(77,/( (;,76 6+$:&2175$&7 $//$&&(66_3$&(7,/( [ 67(3 0212/,7+,&,167$//$7,21 
,17(5,253$,17,1*

,17(5,253$,17,1*
3 *(1(5$/',1,1*3$,17 *(1(5$/821 6+(50,1:,//,$06 3$66,9( 6:
(**6+(//),1,6+


,17(5,253$,17,1*
3 $&&(173$,17 35,9$7(2)),&(63$,17(''2256$1'
+0'22575,0
6+(50,1:,//,$06 67$03('&21&5(7(
6:
(**6+(//),1,6+


,17(5,253$,17,1*
3 $&&(173$,17 6((3/$16 6+(50,1:,//,$06 ',67$1&(
6:
(**6+(//),1,6+


,17(5,253$,17,1*
3 $&&(173$,17 6((3/$16 6+(50,1:,//,$06 ,17+(1$9< 6:

(**6+(//),1,6+

3/$67,&72,/(7&203$570(176
3/$67,&72,/(7&203$570(176
73 &$53(77,/( 6(&21'/(9(/5(6752206 $6, 62/,'3/$67,& +'3(
3$57,7,216 &+$5&2$/


)/225$1&+25('29(5+($'%5$&('
:,1'2:6+$'(6:,1'2:6+$'(6 56 52//(56+$'( 6((3/$16 0(&+26+$'(6 0$18$/52//(56+$'(6:,7+ (&29(,/6&5((16
23(1

6,/9(5%,5&+ $''$/7725(3/$&($//:,1'2:6+$'(63(53/$1 &2817(57236&2817(57236 3/ 3/$67,&/$0,1$7(&2817(5 %5($.5220 )250,&$ 6($6($/7




6,*1$*(/(*(1'

&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 255 of 1531 ends

3)
%85($8
6(5*($17

0((7,1*

2)),&(

'521((48,3
6725$*(

'(7(&7,9(
(48,30(17

(/(&75,&$/

:20(1


0(1

+$//

-$1

+$//

6725$*(

67$,5

67$,5

%5,(),1*
5220

+$//


/2%%<

(/(9

6+$5('
2)),&(












6((6833257,1*'2&80(176)25)851,785(6&+('8/(


%5($.
5220

,1&,'(17
&20

6(
&*
6(
&*
&*
6(
&*
6(
&*
6(
&*

6(
6767
&*
6(
6767
67
&*
6(
67
6(
6(
67 67



&*


6(
6(
&*
&*&*
(
(
(
((
67
7<37<3
67 67
23(1
2)),&(

67
&*
7<37<3
67
7<3
&*

67

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

),567)/225)851,785(3/$1
$
-+
-5

-5
$ 6&$/(
 

 ),567)/225)851,785(3/$1
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 256 of 1531 ends

83 83
%5($.
5220

6(59(5

:20(16

0(16


0((7,1*
5220

(/(9$725

&23<
5220

(/(90(&+

'(37
&+,()

&5,0(
$1$/<67


75$,1+,5,1*
0$1$*(5

(48,3

$'0,1
$
'(37
&+,()

,17
$))$,56
/,(87

%5($.
5220
 %26
0$1$*(5

38%/,&
$))$,56
0$1$*(5

+$//


-$1

&21)

67$,56

67$,56

-$1

&+,()
&
5()
6725$*(
67
&*
6(
67
6(6(
&*&*
6(
&*
6767
&*
6(6(
67
&*
6(6(

67
6(
&* 67
67
&*
6(6(
6767
&*
6(6(6(
&*
6(
&*
67
6(
67
&*
6767
&*
6(6(

 
 
 
 




 

 
 

&*









&*
67 6(
6(
67
&*
67
&*
&*
67
&*
&*
&*&*
6(6(
6(
&*
&*
&*
6767
(
&*
67
6767
&*
6(6(
&*
6((6833257,1*'2&80(176)25)851,785(6&+('8/(

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

6(&21')/225)851,785(3/$1
$
-+
-5

-5
$ 6&$/(
 

 6(&21')/225)851,785(3/$1
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 257 of 1531 ends


 : 






+
+
:
7<3($
)
'2257<3(6)5$0(7<3(6))
+
:
7<3('
)8///,7(2%6&85('::,1'2:35,9$&<
+),/0
:
7<3(%
 

 

 
 


9 
,
)







9 
,
)










9,)



 
























$/80,1806725()5217
;
),;('
6

$


$


$

9 
,
)











)/2$7*/$667(03(5('2%6&85('*/$667(03(5(',167$//:,1'2:35,9$&<),/0 */$=,1*/(*(1' 7<3,&$/'(7$,/6
7<3,&$/-$0%$7$'-$&(176725()5217
$/80,1806725()5217
;
'225:,7+75$1620
6
9,)



 

9 
,
)



































)8///,7(2%6&85('::,1'2:35,9$&<),/0

$


$

 &/ +0 03 67/ :' 7
&+$,1/,1.+2//2:0(7$/0(7$/3,&.(767((/:22'6$)(7<*/$=,1* )8///,7(2%6&85('::,1'2:35,9$&<),/0
$/80,1806725()5217
;
6

 
 
 
 
 
 




















































$


$


$








$
$/80,1806725()5217
;

$


$


$

6

























 




 

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'225$1':,1'2:6&+('8/(6
$
-+
-5

-5
'2257<3(6/(*(1' '2256&+('8/(
 5()(572*(1(5$/127(6216+((7*)25$'',7,21$/ 5(48,5(0(176
 5()(572)/2253/$16)25'225/2&$7,216 &2175$&725729(5,)<(;$&7528*+23(1,1*6,=(6:,7+'225 0$18)$&785(563(&,),&$7,21635,2572)$%5,&$7,212)528*+23(1,1*6  &2175$&725729(5,)<$&78$/'2256,=(672),7),1,6+23(1,1* 35,2572)$%5,&$7,212)'225$1'),1,6+23(1,1*
 5()(572'2257<3(6/(*(1')25*/$=,1* 5()(57275(3257)25*/$=,1*(1(5*<5(48,5(0(176 ,167$//3(50$18)$&785(56:5,77(1,16758&7,216 5()(572),1,6+6&+('8/(21$$1'$)25'225$1')5$0( 3$,17&2/256
'225*(1(5$/127(6
 (*5(66'225 (48,33(':3$1,&+$5':$5( ,1&/8'(66$)(7<*/$=,1* ),5(5$7(''225$66(0%/<9,6,213$1(/625/,7(6725(&(,9(:,5( */$66
 /289(5(''225 (;,67,1*'22572&+$1*(6:,1*',5(&7,21)520,172287$'-867 $1'5(,167$//+$5':$5($61(('('
 &/26(5%8712/$7&+386+3/$7(3529,'(' 3529,'(35,9$&</2&.6(7720$7&+(;,67,1* '2255(0$5.6
12
6,=( '225 )5$0( +$5':$5(
*5283
'(7$,/
:,'7+ +(,*+7 7+,&.1(66 7<3( 0$7
/ 7<3( 0$7
/ 6,// -$0% +($' 5(0$5.6
$ 
 
  ' $/80 ) $/80  $
 $
 $
 % 
 
  % :' ) +0  $
 $
 
 
 
  % :' ) +0  $
 $
 
$ 
 
  ' $/80 ) $/80  $
 $
 $
 % 
 
  ' $/80 ) $/80  $
 $
 $
 
 
 
  $ $/80 ) $/80  $
 $
 $
 
 
  % :' ) +0   
 
  % :' ) +0  $
 $
 
($ 
 
  (;,67 (;,67 (;,67 (;,67 
( 
 
  (;,67 (;,67 (;,67 (;,67 
:,1'2:$1'6725()52177<3(6
'2250$7(5,$//(*(1'
 5()(572*(1(5$/127(6216+((7*)25$'',7,21$/ 5(48,5(0(176
 5()(572)/2253/$16)25:,1'2:/2&$7,216 &2175$&725729(5,)<(;$&7528*+23(1,1*6,=(6:,7+:,1'2: 0$18)$&785(563(&,),&$7,21635,2572)$%5,&$7,212)528*+23(1,1*6  &2175$&725729(5,)<$&78$/:,1'2:6,=(672),7),1,6+23(1,1* 35,2572)$%5,&$7,212):,1'2:$1'),1,6+23(1,1*
 +($'+(,*+70($685(')520))81/(66127('27+(5:,6( 5()(572(1(5*<&203/,$1&(5(32576)258)$&7256+*&$1' $'',7,21$/:,1'2:5(48,5(0(176
 $//(;7(5,25*/$=,1*,6'28%/(3$1(81/(6627+(5:,6(127(' 5()(5726725()5217$1':,1'2:7<3(6/(*(1')25*/$=,1*  $//*/$=,1*,672%(6$)7(<*/$=,1*
7(03(5('
 $//23(5$%/(:,1'2:6$5(72%(3529,'(':,7+/,0,7(56 5(675,&7,1*:,1'2:352-(&7,21672
 $//23(5$%/(:,1'2:6$5(72%(3529,'(':,7+:,1'2:6&5((16 :,1'2:*(1(5$/127(6



&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 258 of 1531 ends

(
&21&5(7(6/$%
$/80,180
6725()5217)5$0(%(<21'
$/80,180
6725()5217'225)5$0( '225
+($'-$0%6,0,/$5
*<3680%2$5':$//)5$0,1*+2//2:0(7$/'2256<67(0'2253$1(/G[1$,/63(50$18))/225),1,6+ 0 $;





(
0(7$/678':$//)5$0,1*$/80,180
6725()5217
(4 (4

(
*<3%'
127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1

(
9(5,)<,1),(/'

$))
%$&.(552'$1'6($/$177<3&$6,1*%($'75,0

(
&21&5(7(6/$%6+,0$/80,1806725()5217
)5$0(%(<21'
%$&.(552'$1'6($/$177<3$/80,1806725()5217
6+,0*<3%'$/80,1806725()5217
(4 (4
3/</,*+7*8$*(0(7$/678'6-&$6,1*%($'75,0%$&.(552'$1'6($/$177<3 $/80,180
6725()5217

(
62)),7)5$0,1*
(4 (4
*<3%'
(;,67,1*62)),7)5$0,1*725(0$,1

(
9(5,)<,1),(/'
%$&.(552'$1'6($/$177<3
127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1

(
67((/678')5$0,1*725(0$,1
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21

 

'225 :,1'2:'(7$,/6
$

-+
-5

-5
$ $
 6&$/(
 

 ,176725()5217'225
$
 6&$/(
 

 ,17'225 +($'-$0%
$ $
 6&$/(
 

 6725()52176,//#
(
:$//
$ $
 6&$/(
 

 $/806725()52176,//#)/225
$ $
 6&$/(
 

 $/806725()5217-$0%+($'
$ $
 6&$/(
 

 6725()5217+($'#
(
62)),7
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 259 of 1531 ends

(
67((/678'725(0$,1

(
*<3%'725(0$,1
1 *<3%'

(
9(5,)<,1),(/'
/,*+7*8$*(07/678'&251(5%($'
/,*+7*8$*(07/678'6&+('8/('),1,6+7<3+,/7,;83%6:)/$7:$6+(5#2&  2)(1'60,1(0%(' ,&&(6(65

(
&21&)/225%27720&+$11(/
127(
 :$//)5$0,1*72$&&202'$7(/%6),17/2$' /,1(&$8/.%(7:((1:$//$1'5811(5 7<3

0(7$/678':$//)5$0,1*6$&2867,&$/&(,/,1*
3$1(/
127(
:$//)5$0,1*72$&&202'$7(/%6),17/2$'
:$//6281',168/$7,21
$
%
2 9
(
&
/
1 *






/,*+7*8$*(0(7$/678'
6
%5$&(726758&785(
$%29(#2&67$**(5('
72375$&.7
127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1
6,03621$$77$&+(':6(/)7$33,1*6&5(:6726,'(2)%5$&( $1'7232)75$&.
$77$&+%5$&(7275$&.:,7+
6(/)7$33,1*6&5(:6$77$&+75$&.72(;,67,1*522)'(&.

(
)5$0,1*6&5(:6#2&;*$62)),7)5$0,1*#2& 5()(5725&3)2562)),77<3(6;%5$&,1*# 2&$77$&+726758&785$/)5$0,1*:6,03621'7&
6/277('/(*9(57-
#($&+-2,67252&#%/2&.,1*6&+('8/('&(,/,1*:$//3(53/$1*$;07/678'25;%/2&.,1*3(5)5$0,1*&251(5%($'6&+('8/('),1,6+ 7<3 6&5(:6#2& 5()(5725&3
5()(5725&3







$


$


$



(
$&2867,&$/&(,/,1*7,/(5()(5725&3
127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1

(
$&7
$))

(
67((/678'725(0$,1

(
&21&6/$%
$&2867,&$//$<,1
7,/(&(,/,1*5()(5725&3
*<3%'&(,/,1*5()(5725&3

$))


$))

$))
(;,67,1*%8/.+($'72%(5(029('

(
07/678'.,&.(56#2&%5$&('726758&785($%29(9,) *<3%'&(,/,1*5()(5725&3
*<3%'

/,*+7*8$*(07/678'6
&251(5

 %($'
*<3%'/,*+7*8$*(0(7$/678'
6
%5$&(72:$//

(
67((/678'725(0$,1

(
*<3%'725(0$,1
*<3%'&(,/,1*5()(5725&3/,*+7*8$*(07/678'6 &251(5%($'

(
%8/.+($'+7
9(5,)<,1),(/'
$&7


$))
127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1
$&2867,&$/&(,/,1*7,/(
5()(5725&3
/,*+7*8$*(0(7$/678'
6
%5$&(72:$//
/,*+7*8$*(0(7$/678'6
127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1
/,*+7*8$*(0(7$/678'
6
%5$&(726758&785($%29(#2&67$**(5('
$/80,180
6725()5217
%$&.(552'$1'6($/$177<3

(
0(7$/678'62)),7)5$0,1*725(0$,1*<3%':+(5(2&&856)$67(172 (
62)),7)5$0,1*5()(5725&31(:$&7:+(5(2&&8565()(5725&3 *<3%'
&(,/,1*62)),7
5()(5725&3 5()(5725&3
5()(5725&35()(5725&3
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(7$,/6
$

-+
-5

-5
$
 6&$/(
 

 7<3%8/.+($'
$
 $
 6&$/(
 

 7<33$57,7,2172)/225
$
 6&$/(
 

 3$57,7,21%5$&,1*3$57,$/+7
$
 6&$/(
 

 7<362)),7)5$0,1*
$ $
 6&$/(
 

 :$//6(&7,21 6+$5('2)),&(
$
 $
 6&$/(
 

 &(,/,1*)5$0,1*
$
 $
 6&$/(
 

 &(,/,1*)5$0,1*
$ $
 6&$/(
 

 62)),7'(7$,/
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 260 of 1531 ends


§

(/(9$7,21
:22'678'65()726758&785$/;%/2&.,1*&211(&7($&+(1'2)%/2&.,1*72678',1$1<0(+72''(7$,/('%(/2:$7&2175$&725 6237,218212))6(7$7($&+678'%$<72
$92,')$67(1(5&21)/,&7
86(
:22'6&5(:0,172$77$&+$&&(6625,(672%/2&.,1*821)25 0,55256)/$76,*167$&.%2$5'6&+$/.%2$5'60$5.(5%2$5'6%8//(7,1%2$5'6)5$0('$57:25.127(6  '2127&8725127&+678'672,167$//%/2&.,1* 9(5,)</(1*7++(,*+748$17,7<$1'/2&$7,21)25%/2&.,1*:,7+ $5&+,7(&785$/'(7$,/6$1'$&&(6625<0$18)$&785(5
 (;7(1'%/2&.,1*72),567678'3$67(1'2)$&&(6625< 5()(5726758&785$/'(7$,/6)250,1,080/2$'/,0,7621%/2&.,1* $7;678'21/<


G(1'1$,/6[678'[%/2&.

G72(1$,/6723 %2772021)$&()/86+:678'678'$1<7+,&.1(66[%/2&.678'$1<7+,&.1(66[%/2&.6,03621$723 %27720 G1$,/672($&+0(0%(5

0(7+2'$0(7+2'%0(7+2'&
$$
6(&7,21$$
3/$1
;%/2&.,1*:22'678'6
(/(9$7,21 6(&7,21
3/$1
6,03621$$7($&+(1'2)%/2&.,1*
$/7(51$7(723 
%277207<32))6(7%/2&.,1*$7($&+678'%$<72
$92,')$67(1(5
&21)/,&7:22'678'65()726758&785$/;%/2&.,1*86(
:22'6&5(:0,172$77$&+
$&&(6625,(672%/2&.,1*821
)25
72,/(7 %$7+$&&(6625,(6'22567236'225+2/'(56&$%,1(76',63/$<&$%,1(7672,/(73$57,7,216127(6  '2127&8725127&+678'672,167$//%/2&.,1* 9(5,)</(1*7++(,*+748$17,7<$1'/2&$7,21)25%/2&.,1*:,7+ $5&+,7(&785$/'(7$,/6$1'$&&(6625<0$18)$&785(5
 (;7(1'%/2&.,1*72),567678'3$67(1'2)$&&(6625< 5()(5726758&785$/'(7$,/6)250,1,080/2$'/,0,7621%/2&.,1* 86(
:22'6&5(:0,125',$0(7(5:22'6&5(:0,172$77$&+ $&&(6625,(672%/2&.,1*821
)25
+$1'5$,/6*5$%%$566+2:(56($766+(/)%5$&.(76&2817(5723%5$&.(7685,1$/6&5((16:$7(5+($7(5675$366,1.%5$&.(76(7& $$
$$
[[/21*0(7$/6833257:
'(*5((/(*/21*%2/7('72&2817(5#2&0,5525:$//)5$0,1* 5()(572)/2253/$1%$&.63/$6+62/,'685)$&(&2817(57233(563(&3/<:22'2[)5$0,1*

6.,57720$7&+&2817(5723
6,1.3(53/80%,1*0(7$/68333257%5$&.(7:

%2/7672[&2817(5723)5$0,1*[%/2&.6&5(:('72678'%/2&.:$67(3,3,1* 6((3/80%,1*3/$1*$3/$7(:6&5(:6:$//),1,6+5()(5726&+('8/(&/($5=21(6(('(7$,/7[[[[:$7(55(6,67$17*<3680%2$5' :$//)5$0,1* 5()(572)/2253/$1)25:$//7<3(6
&$%,1(73529,'(6/((9(1876 6&5(:)$67(1(56%(7:((1($&+&$%,1(781,7#723 %27720)5217 %$&.%/2&.,1*$7&$%,1(7723 %27720*<3680%':$//),1,6+ 23/<:22'6+($7+,1*3(56758&785$/:2
:6#2&0,1

3(5&$%,1(7723$1'%27720
7232)833(5&$%,1(75()72,17(/(9$7,216




7 <
3 
7<3821

(
*<3680%2$5'
(
:$//)5$0,1* 5()(572
)/2253/$1)25:$//7<3(6
3529,'(%/2&.,1*$7723 %277202)$//833(5%$6($1')8//+(,*+7&$%,1(76$1':$//+81*$&&(6625,(6 ;)+:6#2&0$;;)+:6&$%,1(73(5,17(5,25(/(9$7,216 58%%(5%$6(6&+('8/('),1,6+)/225
;;*$&217,1828675$&.127&+ )$67(172678'6:606

(
:$//)5$0,1*
(
*<3680%2$5'%$&.63/$6+
:+(5(2&&856
%/2&.,1*/$0,1$7(&2817(5723)$&(2)&$%,1(7
7232)&2817(5
5()72,17(/(9$7,216
6LQN
SHU3ODQV

6HDODQWDURXQGSHULPHWHU
6(&7,21
1RWH
3URYLGHEDFNLQJLQZDOOIUDPLQJDVUHTXLUHGIRUORZHUDQGXSSHUFDELQHWVXSSRUW 6WDLQOHVV6WHHO&RXQWHUWRS
,QVXODWHH[SRVHGZDWHUVXSSO\DQGGUDLQSLSHV
WKHUHVKDOOEHQRVKDUSRUDEUDVLYHVXUIDFHVXQGHUVLQN 3/$1
5HPRYH'RRUVRU3RFNHWDZD\SURYLGHGPLQFOUZLGWKPHW 0,1&/5:25.63$&(#:25.67$7,21
3(53/$16
)LQLVK6LGH3DQHOV7\S8QGHU6LQN6LQN
SHU3ODQV

9HULI\%DVLQ'HSWKSHU.QHH&OHDUDQFH
2IIFHQWHU5HDU'UDLQ
,QVWDOOSHU0DQXI6SHFLILFDWLRQV

.LWFKHQ$FFHVVLELOLW\1RWHV7KHVLQNDQGZRUNVXUIDFHWREHVHSDUDWH 
FRPSRQHQWV%DVHFDELQHWGRRUVGLUHFWO\XQGHUWKHFRXQWHUDUHDVKDOOEHUHPRYDEOHZLWKRXWWKHXVHRIVSHFLDOL]HGWRROVRUVSHFLDOL]HGNQRZOHGJHRUVKDOOSRFNHWDZD\LQRUGHUWRSURYLGHFOHDUDQFHIRUDZKHHOFKDLU7KHILQLVKIORRUEHQHDWKWKHFRXQWHUDUHDVKDOOEHH[WHQGHGWRWKHUHDUSDQHO:LWKGRRUVUHPRYHGRUSRFNHWHGDZD\WRHDQGNQHHFOHDUDQFHWRFRPSO\ZLWKGHWDLO )DXFHWFRQWUROVDQGRSHUDWLQJPHFKDQLVPVVKDOOEHRSHUDEOHZLWKRQHKDQGDQGVKDOOQRWUHTXLUHWLJKWJUDVSLQJSLQFKLQJRUWZLVWLQJRIWKHZULVW7KHIRUFHUHTXLUHGWRDFWLYDWHFRQWUROVVKDOOEHQRJUHDWHUWKDQSRXQGIRUFH 1
/HYHURSHUDWHGSXVKW\SHDQGHOHFWURQLFDOO\FRQWUROOHGPHFKDQLVPVDUHH[DPSOHVRIDFFHSWDEOHGHVLJQV6HOIFORVLQJYDOYHVDUHDOORZHGLIWKHIDXFHWUHPDLQVRSHQIRUDWOHDVWVHFRQGV 


0 $
;

5HWUDFWDEOHKDUGZDUHDWVLQNFDELQHWEDVH
GRRUVSRFNHWDZD\RUPD\EHUHPRYHG
)LQLVK,QWHULRU6LGH3DQHOV
%(7:((16,'(3$1(/6
0,1&/5


8 Q
G
H
U
6 Q
L
N



0 Q
L

.

Q
H
H
&
H
O
D
U
D
Q
F
H
(/(9$7,21
)LQLVK%DFNDQG,QVLGHVRI&DELQHW
7 2
5 (
$
5 2
)
&
$
%
1 ,
(
7 




([WHQG)LQLVK)ORRULQJ8QGHU&DELQHW
*<3680%2$5':$//)5$0,1* 5()(572)/2253/$16)25:$//7<3(66(0,5(&(66('&$%,1(7 $77$&+3(50$18)5(&200(1'$7,216:5$3*<3680%2$5',17223(1,1* 02817:,7+23(5$%/(3257,212)&$%,1(725(;7,1*8,6+(5 $70$;$))
0$;
&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(7$,/6
$

-+
-5

-5
$
 6&$/(
 

 7<3;%/2&.,1*
$
 6&$/(
 

 7<3;%/2&.,1*
$
 6&$/(
 

 /$9$725<&2817(5
$
 6&$/(
 

 %$6(&$%,1(7
$
 6&$/(
 

 %$6(&$%,1(7$1&+25$*(
$
 6&$/(
 

 /$0,1$7(&2817(5723
$ $
 6&$/(
 


$&&.,7&+(1:25.67$7,21$1'6,1.
$
 6&$/(
 

 ),5((;7,1*8,6+(5
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 261 of 1531 ends

6/23(
7<3
:$7(53522)0(0%5$1()/225'5$,1 5()(5723/80%,1*3/$16 6/23(
0$;
'5$,16(7)/86+:,7+),1,6+)/225&(5$0,&7,/(29(57+,16(70257$5$1'0257$5%(' &$53(7

,)!+,*+7+(13529,'(
%(9(/





/8;85<9,1</7,/(),1,6+3(56&+('8/(675$,*+7('*(75,0

(
&21&5(7(6/$%0257$5%('&(5$0,&)/2257,/(&29('&(5$0,&)/2257,/(&(5$0,&7,/(7+,16(729(5&(0(17%2$5'2505*<3%2$5'$663(&,),(' 5()(572,17(5,25(/(96
&(5$0,&7,/(%8//126(7+,16(729(5&(0(17%2$5'2505*<3%2$5'$663(&,),(' 127(
6+$'('(/(0(1766+2:1$5((;,67,1*725(0$,1
5(6,/,(17%$6(:$//),1,6+



*<3680:$//%2$5'),1,6+)/225 5(6,/,(17%$6(
:$//),1,6+



*<3680:$//%2$5'),1,6+)/225
(
&21&5(7(&85%
1 :+(5(2&&85686(&216758&7,21
$'+(6,9(72
6(&85(*:%72&21&5(7(&85%

(
&21&6/$%

(
&21&6/$%
:,7+287&85% :,7+&85%
7+528*+%2/76:,7+:$6+(5621%$&.6,'(7<30,1&87$5281'02817,1*3/$7(%$&.,1*3(56758&785$/)5$0,1*678'*<3680%2$5'02817,1*3/$7(:$//02817(''5,1.,1*)2817$,102817,1*678'6 

&

5(1(:$/'$7(

/
$/
#
- .) $
'
.
/
/ *!

'$!*-)$
-21$7+$1 .& 28 +
:$/1877(1$17,03529(0(17
&,7<63(&,),&$7,2112'$7(

352-(&77,7/(

6+((77,7/(

6+((712'(6,*1('%<
'5$:1%<
&+(&.('%<

$33529('%<

6&$/(
3/$1),/(12/2&$7,21
$VLQGLFDWHG
'(7$,/6
$

-+
-5

-5
$
 6&$/(
 

 )/225'5$,1
$
 6&$/(
 

 &$53(772/9775$16,7,21
$
 6&$/(
 

 %$6( ,17(5,25 &7
$
 6&$/(
 

 *:%7(50,1$7,21$1'%$6(
$
 6&$/(
 

 '8$/:$//02817)2817$,1
&

5(1(:$/'$7(

/
/ # )
'
.
/
/ !*-)
-21$7+$1 .& 28 +
9/13/24

Page 262 of 1531 ends

MECHANICAL GENERAL NOTES 1 COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES:
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC): PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR)
2022 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24 CCR2022 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24 CCR2022 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24 CCR2022 CALIFORNIA PLUMBING CODE (CPC): PART 5, TITLE 24 CCR2022 CALIFORNIA ENERGY CODE (CENC): PART 6, TITLE 24 CCR2022 CALIFORNIA FIRE CODE (CFC): PART 9, TITLE 24 CCR2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN): PART 11, TITLE 24 CCR REPORT DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED. 2 THESE DRAWINGS ARE A GENERAL GRAPHIC PRESENTATION OF THE WORK. DUCTWORK, PIPING, AND EQUIPMENT, AS SHOWN, ARE SCHEMATIC. FABRICATE AND INSTALL BASED ON ACTUAL FIELD MEASUREMENT. COORDINATE WITH OTHER TRADES. ADHERE TO LOCATIONS AS CLOSELY AS

POSSIBLE, VARY RUNS OR SHAPE OF DUCTWORK AS REQUIRED TO MEET STRUCTURAL AND OTHER INTERFERENCES AS REQUIRED BY THE ARCHITECT. PROVIDE A COMPLETE SET OF SHOP DRAWINGS REFLECTING ACTUAL DIMENSIONS, ACCESS REQUIREMENTS, AND DETAILS BASED UPON THE ACTUALEQUIPMENT PROCURED. MAINTAIN AN UP TO DATE SET OF AS-BUILT DRAWINGS AT THE JOB SITE. 3 THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL ITEMS RELATED TO MECHANICAL SYSTEMS

WITH THE WORK OF OTHER TRADES BEFORE PROCEEDING WITH PROCURING OR FABRICATION OF EQUIPMENT, DUCTWORK, PIPING ETC. ITEMS TO BE COORDINATED SHALL INCLUDE BUT ARE NOT LIMITED TO THE FOLLOWING:

GRILLES, REGISTERS AND DIFFUSERS SHALL BE COORDINATED WITH THE REFLECTED CEILING PLAN.

DUCTWORK LOCATIONS AND POTENTIAL INTERFERENCES WITH STRUCTURAL MEMBERS, FRAMING, FIRE SPRINKLER LINES, PLUMBING WASTE LINES, CABLE TRAYS AND CONDUIT.

ACCESS TO VOLUME DAMPERS FOR BALANCING. ACCESS TO ALL EQUIPMENT, AS WELL AS PLATFORMAND CURB LOCATIONS. 4 REVIEW ALL DRAWINGS AND SPECIFICATIONS INCLUDING ARCHITECTURAL, STRUCTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL. ANY QUESTIONS SHALL BE BROUGHT UP, IN WRITING, TO THE ATTENTION OF THE ENGINEER BEFORE THE START OF CONSTRUCTION. 5 REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF DIFFUSERS, REGISTERS, GRILLES, AND ACCESS PANELS.
6 ALL DUCT DIMENSIONS, AS SHOWN ON MECHANICAL DRAWINGS ARE CLEAR INSIDE DIMENSIONS.

INCREASE OUTER DUCT DIMENSION AS REQUIRED TO ACCOUNT FOR THE THICKNESS OF INTERNAL LINING WHERE APPLICABLE.
7 INSULATION AND FLEXIBLE DUCT SHALL COMPLY WITH STATE FIRE MARSHALL CRITERIA AND SHALL NOT EXCEED FLAME SPREAD OF 25 AND SMOKE DEVELOPED OF 50 PER ASTM-84, NFPA-223, AND UL 723. 8 INSULATE PIPING AND DUCTWORK IN ACCORDANCE TO THE GOVERNING CODES.9 ALL SQUARE ELBOWS IN SUPPLY DUCTWORK SHALL HAVE TURNING VANES. PROVIDE MANUAL VOLUME DAMPER AT EACH BRANCH DUCT TAKE-OFF SERVING EACH AIR TERMINAL DEVICE. PROVIDE BALANCINGDAMPERS FOR EACH MAIN DUCT TAKE-OFF IN ACCORDANCE TO SMACNA IN ORDER TO ASSURE A COMPLETELY BALANCED SYSTEM.
10 MATERIALS EXPOSED WITHIN ANY SPACE BEING USED AS AN AIR PLENUM SHALL BE NON COMBUSTIBLE OR SHALL HAVE A FLAME SPREAD INDEX NOT GREATER THAN 25 AND A SMOKE DEVELOPED INDEX NOTGREATER THAN 50, WHEN TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ONE OF THE FOLLOWING TEST METHODS: NFPA 255, METHOD OF TEST OF SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, ASTM E84, SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, OR UL 723, TEST FOR SURFACE BURNING CHARACTERISTIC OF BUILDING MATERIALS.

PLUMBING GENERAL NOTES 1 COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES:
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC): PART 1, TITLE 24, CALIFORNIA CODE OF REGULATIONS (CCR)
2022 CALIFORNIA BUILDING CODE (CBC): PART 2, TITLE 24 CCR2022 CALIFORNIA ELECTRICAL CODE (CEC): PART 3, TITLE 24 CCR2022 CALIFORNIA MECHANICAL CODE (CMC): PART 4, TITLE 24 CCR2022 CALIFORNIA PLUMBING CODE (CPC): PART 5, TITLE 24 CCR2022 CALIFORNIA ENERGY CODE (CENC): PART 6, TITLE 24 CCR2022 CALIFORNIA FIRE CODE (CFC): PART 9, TITLE 24 CCR2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CAL GREEN): PART 11, TITLE 24 CCR REPORT DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED. 2 NO PLUMBING SHALL BE INSTALLED UNTIL ALL REQUIRED PLUMBING PLAN CHECK PERMITS AND APPROVALS HAVE BEEN OBTAINED FROM ALL REQUIRED AGENCIES. 3 LAVATORY FAUCETS, SINK FAUCETS (NOT INCLUDING SERVICE SINK FAUCETS OR FAUCETS DESIGNATED AS INSTITUTIONAL) SHALL MEET THE FLOW REQUIREMENTS OUTLINED IN THE APPLIANCEEFFICIENCY STANDARDS. 4 COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF PLUMBING FIXTURES AND DRAINS.
5 PROVIDE ALL TAILPIECES, TRAPS, STOPS, AND SUPPLY PIPES TO LAVATORIES DESIGNED AS ACCESSIBLE, WITH PREFORMED INSULATION JACKET.
6 CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF WALLS, ROOFS, FOOTINGS, FLOORS, INCLUDING ALL SAW CUTTING AND CORE DRILLING. COORDINATE ALL SAW CUTTING AND CORE DRILLING WITH STRUCTURAL DRAWINGS. ANY CUTTING AND DRILLING REQUIRED OF STRUCTURALELEMENTS THAT IS NOT SPECIFICALLY SHOWN ON THE PLANS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION PRIOR TO CUTTING AND DRILLING. CONTRACTOR SHALL SUBMIT PROPOSED LOCATION AND

SIZES OF SUCH CUTTING AND DRILLING FOR THE ARCHITECTS AND STRUCTURAL ENGINEERS APPROVAL.
7 COORDINATE INSTALLATION OF ALL EQUIPMENT AND PIPING WITH OTHER TRADES PRIOR TO INSULATION. ENSURE THAT ALL CONTROL DEVICES, SHUT-OFF VALVES, ETC. ARE ACCESSIBLE FOR MAINTENANCE. WHERE ACCESS PANELS IN FINISHED SPACES, OTHER THAN THAT SHOWN,

CONTRACTOR SHALL PROVIDE AND COORDINATE EXACT LOCATION OF PANELS WITH ARCHITECT PRIOR TO INSTALLATION.
8 ANY STRUCTURAL FIREPROOFING DAMAGED DURING INSTALLATION OF PLUMBING EQUIPMENT, PIPING, ETC. SHALL BE REPAIRED AT NO COST TO THE OWNER. REPAIRS SHALL BE AS DIRECTED BY THE ARCHITECT.
9 NEW OR REPAIRED POTABLE WATER SYSTEMS SHALL BE DISINFECTED PRIOR TO USE PER 2022 CPC 609.10. THE METHOD TO BE FOLLOWED SHALL BE THAT PRESCRIBED BY THE HEALTH AUTHORITY OR, IN CASE NO METHOD IS PRESCRIBED BY IT, THE FOLLOWING:

A) THE PIPE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL POTABLE WATER APPEARS AT THE POINTS OF OUTLET.

B) THE SYSTEM OR PARTS THEREOF SHALL BE FILLED WITH A WATER-CHLORINE SOLUTION CONTAINING NOT LESS THAN 50 PARTS PER MILLION OF CHLORINE, AND THE SYSTEM OR PART THEREOF SHALL BE VALVED-OFF AND ALLOWED TO STAND FOR 24 HOURS; OR, THE SYSTEM OF PART THEREOF SHALL BE FILLED WITH A WATER-CHLORINE SOLUTION CONTAINING NOT LESS THAN 200 PARTS PER MILLION OF CHLORINE AND ALLOWED TO STAND FOR 3 HOURS.

C) FOLLOWING THE ALLOWED STANDING TIME, THE SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE

WATER UNTIL THE CHLORINE RESIDUAL IN THE WATER COMING FROM THE SYSTEM DOES NOT EXCEED THE CHLORINE RESIDUAL IN THE FLUSHING WATER.

D) THE PROCEDURE SHALL BE REPEATED WHERE IT IS SHOWN BY BACTERIOLOGICAL EXAMINATION MADE BY AN APPROVED AGENCY THAT CONTAMINATION PERSISTS IN THE SYSTEM.

MECHANICAL LEGEND SYMBOL ABBREVIATION DESCRIPTION
Ø DIA DIAMETER
ɸ ELECTRICAL PHASE

CEILING MOUNTED SUPPLY OR OUTSIDE AIR DIFFUSERCEILING MOUNTED RETURN AIR GRILLECEILING MOUNTED EXHAUST AIR GRILLESIDEWALL MOUNTED SUPPLY AIR DIFFUSER, RETURN

AIR GRILLE, LOUVER
24X12, 24X12 FO RECTANGULAR, FLAT OVAL DUCT
24X12L, 12ØL LINED DUCT

RECTANGULAR SUPPLY / OA, RETURN, EXHAUST /RELIEF DUCT PASSING THROUGH PLAIN OF VIEWRECTANGULAR SUPPLY / OA, RETURN, EXHAUST /RELIEF DUCT TURNING DOWN 12Ø ROUND DUCT

ROUND DUCT TURNING DOWN, ROUND DUCT TURNINGUP
90° ELBOW WITH TURNING VAINS
FLEXIBLE DUCT 60" MAX LENGTH

FC FLEXIBLE CONNECTION

VD MANUAL VOLUME DAMPER

CVD CABLE OPERATED VOLUME DAMPER

ACCESS CLEARANCE

POC OR POD POINT OF CONNECTION, POINT OF DISCONNECTION

ITEMS RELATED TO THE MECHANICAL SYSTEM TO BE

REMOVED

MECHANICAL ABBREVIATIONS
AC AIR CONDITION, AIR CONDITIONING, AIR CONDITIONED HP HORSE POWERABV ABOVE HVI HOME VENTILATING INSTITUTEAFF ABOVE FINISHED FLOOR HZ HERTZAFUE ANNUAL FUEL UTILIZATION EFFICIENCY IDU INDOOR UNITAHJ AUTHORITY HAVING JURISDICTION IWC INCHES OF WATER COLUMNAHU AIR HANDLING UNIT KW KILOWATTALUM ALUMINUM LBS POUNDSAMCA AIR MOVEMENT AND CONTROL ASSOCIATION LWT LEAVING WATER TEMPERATUREAMB AMBIENT MBH 1000 BRITISH THERMAL UNITS PER HOURAP ACCESS PANEL MCA MINIMUM CIRCUIT AMPSARCH ARCHITECT, ARCHITECTURAL MFGR MANUFACTURE OR MANUFACTURERARI AMERICAN REFRIGERATION INSTITUTE MIN MINIMUM ASHRAE

AMERICAN SOCIETY OF HEATING,

REFRIGERATION, AND AIR CONDITIONINGENGINEERS

MUA MAKE-UP AIR

BDD BACK DRAFT DAMPER (N) NEW

BOD BASIS OF DESIGN NL NOT LISTED

BEL BELOWNOMNOMINAL

BHP BREAK HORSE POWER NTS NOT TO SCALEBLDG BUILDING OA OUTSIDE AIRBTUH BRITISH THERMAL UNIT PER HOUR OAI OUTSIDE AIR INTAKE

CA COMBUSTION AIR OBD OPPOSED BLADE DAMPERCD CONDENSATE DRAIN ODU OUTDOOR UNITCFD CEILING FIRE DAMPER OSHPD OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENTCFM CUBIC FEET PER MINUTE PD PRESSURE DROPCONT CONTINUATION PSI POUNDS PER SQUARE INCHCSD CEILING SMOKE DAMPER RA RETURN AIR

DB DRY BULB TEMPERATURE REFRIG REFRIGERANT, REFRIGERATIONDNDOWN RM ROOMDSA DIVISION OF THE STATE ARCHITECT RPM REVOLUTIONS PER MINUTEDTR DOWN THROUGH ROOF SA SUPPLY AIR (E) EXISTING SEER SEASONAL ENERGY EFFICIENCY RATION

EA EXHAUST AIR SHT SHEETEC EVAPORATIVE COOLER SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATIONEDB ENTERING DRY BULB TEMPERATURE SOV SHUT OFF VALVEEER ENERGY EFFICIENCY RATIO SP STATIC PRESSUREEFF EFFICIENCY SS STAINLESS STEELELEC ELECTRICAL SSE STEADY STATE EFFICIENCY

ESP EXTERNAL STATIC PRESSURE SST SATURATED SUCTION TEMPERATURE

EWB ENTERING WET BULB TEMP TEMPORARY, TEMPERATUREEWT ENTERING WATER TEMPERATURE TSPTOTAL STATIC PRESSUREFA FROM ABOVE TYP TYPICALFC FLEXIBLE CONNECTION TXV THERMAL EXPANSION VALVEFD FIRE DAMPER UON UNLESS OTHERWISE NOTEDFLA FULL LOAD AMPS UTR UP TO OR UP THROUGH ROOF

FPM FEET PER MINUTE VD VOLUME DAMPER

FSC FAN SPEED CONTROLLER VEX VEHICLE EXHAUST SYSTEM

FSD FIRE/SMOKE DAMPER VRF VARIABLE REFRIGERANT VOLUME

GA GAGE, GAUGE WB WET BULB TEMPERATUREGALV GALVANIZED WC WATER COLUMNGPM GALLONS PER MINUTE WG WATER GAUGEGYP GYPSUMWT WEIGHT EXPRESSED IN POUNDS

HD HEAD

PLUMBING ABBREVIATIONS

ABV ABOVE HD HEAD

ADA AMERICANS WITH DISABILITIES ACT HP HORSE POWER

AFF ABOVE FINISHED FLOOR HZ HERTZAG ABOVE GRADE IE INVERT ELEVATIONAHJ AUTHORITY HAVING JURISDICTION IWC INCHES OF WATER COLUMNALUM ALUMINUM KW KILOWATTSAMB AMBIENT LAV LAVATORY

AMP AMPERAGE LBS POUNDS

ARCH ARCHITECT, ARCHITECTURAL LWT LEAVING WATER TEMPERATURE BEL BELOW MAX MAXIMUMBF BELOW FLOOR MBH 1000 BRITISH THERMAL UNITS PER HOURBG BELOW GRADE MCA MINIMUM CIRCUIT AMPSBFP BACKFLOW PREVENTOR MECH MECHANICALBLDG BUILDING MFGR MANUFACTURE OR MANUFACTURERBOD BASIS OF DESIGN MIN MINIMUM

BTUH BRITISH THERMAL UNIT PER HOUR MU MAKE-UP

CA COMBUSTION AIR (N) NEWCD CONDENSATE DRAIN NOMNOMINALCFH CUBIC FEET PER HOUR NPS NOMINAL PIPE SIZECONN CONNECTION NTS NOT TO SCALECONT CONTINUATION OPT OPERATINGCI CAST IRON OSHPD OFFICE OF STATEWIDE HEALTH PLANNING

AND DEVELOPMENT

CP CHROME PLATED PD PRESSURE DROP

DFU DRAINAGE FIXTURE UNITS PH PHASE

DN DOWN PSI POUNDS PER SQUARE INCHDSA DIVISION OF THE STATE ARCHITECT PW PROCESS WASTE (E) EXISTING RM ROOM

EC EVAPORATIVE COOLER RPM REVOLUTIONS PER MINUTE

EFF EFFICIENCY SDL STORM DRAIN LEADERELEC ELECTRICAL SDO STORM DRAIN OVERFLOW

EQPT EQUIPMENT SHT SHEET

EWT ENTERING WATER TEMPERATURE SOV SHUT OFF VALVEFA FROM ABOVE SS STAINLESS STEELFC FLEXIBLE CONNECTION TEMP TEMPORARY, TEMPERATUREFLA FULL LOAD AMPS TYP TYPICALFLR FLOOR UON UNLESS OTHERWISE NOTED

FPS FEET PER SECOND UTR UP TO OR UP THROUGH ROOF

FR FROM V VENT

FT FLUSH TANK VAC VACUUM

FV FLUSH VALVE VTR VENT THROUGH ROOF

GA GAGE OR GAUGE WC WATER CLOSETGALV GALVANIZED W WASTEGPC GALLONS PER CYCLE W/ WITHGPF GALLONS PER FLUSH W/O WITHOUTGPM GALLONS PER MINUTE WSFU WATER SUPPLY FIXTURE UNITGYP GYPSUMWT WEIGHT EXPRESSED IN POUNDSGW GREASE WASTE

SHEET INDEX SHEET NUMBER SHEET TITLE
MP-000 MECHANICAL & PLUMBING GENERAL
MP-001 MECHANICAL & PLUMBING SCHEDULES
MP-002 MECHANICAL & PLUMBING DETAILS
EC-000 ENERGY COMPLIANCE DOCUMENTATION
MPD-101 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN MPD-102 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN MP-200 MECHANICAL & PLUMBING FIRST FLOOR PLANMP-300 MECHANICAL & PLUMBING SECOND FLOOR PLAN

PLUMBING LEGEND SYMBOL ABBREVIATION DESCRIPTION

BALL VALVE

BFV BUTTERFLY VALVE

CAPCHECKVALVE

COTG CLEAN OUT THROUGH GRADE
Ø DIA DIAMETER
ɸ ELECTRICAL PHASE

FCO FLOOR CLEAN OUT

SHUT OFF VALVE IN PIPE DROP OR PIPE RISER

YB SHUT OFF VALVE IN YARD BOX

STRAINER

TPV TRAP PRIMER VALVE

UNIONPIPE DOWNPIPE UP

PIPE TEE DOWN

PIPE INTERSECTIONPLUG VALVE ELEVATION VIEW

PV PLUG VALVE PLAN VIEW

POC OR PODPOINT OF CONNECTION OR POINT OF DISCONNECT

PRV PRESSURE REDUCING OR REGULATOR VALVE

WCO WALL CLEANOUT

CW COLD WATER

CD CONDENSATE DRAIN

HW HOT WATER

V SANITARY VENT

TP TRAP PRIMER

S/W WASTE (ABOVE GRADE)S/W WASTE (BELOW GRADE)S/W EXISTING WASTE WCO
CD
TP TP

PROJECT TEAM LIST

TITLE NAME DESK NUMBER EMAIL ADDRESS
PROJECT MANAGER DENVER STANGER 805.540.5388 [email protected] MECHANICAL DESIGNER DENVER STANGER 805.540.5388 [email protected] PLUMBING DESIGNER RANDY CARMINATI 805.540.3363 EXT 319 [email protected] CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Lead Sheets.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068 M 340
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING GENERAL
MP-000

Page 263 of 1531 ends

COMMERCIAL GRILLE, REGISTER, DIFFUSER, LOUVER SCHEDULE

TAG TYPE MAKE MODEL

BORDER TYPE

CONSTRUCTION FINISH IMAGE REMARKS INSTALLATION G DETAIL YP BOARD CEILING

OR WALL
LAY-IN

CEILING

CEILING
SUPPLY TITUS TDC 1 3 STEEL WHITE

MECHANICAL CONTRACTOR SHALL

COORDINATE WITH THE GENERALCONTRACTOR AND FRAMING CONTRACTOR

TO INSURE OPENINGS IN HARD CEILINGS

AND WALLS ARE CORRECTLY SIZED TOACCOMMODATE THE SPECIFIED BORDER TYPE. NO EXCEPTIONS
3/MP-002

CEILING OR

SIDEWALL

RETURN AND

EXHAUST
TITUS 350RL 1 3 STEEL WHITE

MECHANICAL CONTRACTOR SHALL

COORDINATE WITH THE GENERALCONTRACTOR AND FRAMING CONTRACTOR

TO INSURE OPENINGS IN HARD CEILINGS

AND WALLS ARE CORRECTLY SIZED TOACCOMMODATE THE SPECIFIED BORDER TYPE. NO EXCEPTIONS
SEE 3/MP-002 FOR
DUCTED

EXHAUST AIR

GRILLES
SEE 4/MP-002 FOR

PLENUM RETURN

AIR GRILLES
CEILING SUPPLY DEFLECTION LEGEND (EXCEPT FOR 4-WAY DEFLECTION, SHADING INDICATES ACTIVE SECTION OF DIFFUSER) 4-WAY 3-WAY 2-WAY CORNER 2-WAY OPPOSITE 1-WAY
12x12 S1 400
NECK SIZE (length x width or length x height)CFM FD = FIRE DAMPER FD FSD = FIRE/SMOKE DAMPER OAI = OUTSIDE AIR INTAKE
X"Ø = INLET SIZE (IF APPLICABLE)

DIFFUSER, GRILLE, LOUVER
MARK: S = SUPPLY; R = RETURN;
E = EXHAUST; T = TRANSFER;L = LOUVER; O = OUTSIDE AIR
S1
R1
E1

PLUMBING FIXTURE SCHEDULE

TAG FIXTURE

BRANCH SIZE

ELECTRICAL MODEL & FITTINGS W V CW HW
DF-1 DRINKING FOUNTAIN -
ACCESSIBLE 2" 1-1/2" 1/2" NA NA
DUAL HEIGHT DRINKING FOUNTAIN WITH BOTTLE FILLER, HAWS #1117LN-1920, IN

WALL MOUNTED, STEEL MOUNTING PLATE, STAINLESS STEEL BOTTLE FILLER, PROVIDE WITH STOPS AND SUPPLIES, INSTALL PER ACCESSIBLE FACILITYREQUIREMENTS.

IMS-1 ICE MAKER SUPPLY NA NA1/2" NA NA OATEY #39152, 6"X6"X3-3/8" PLASTIC BOX RECESSED IN WALL W/BRASS QUARTER TURN VALVE. PROVIDE WITH WATER HAMMER ARRESTOR.

LAV-1 LAVATORY -
ACCESSIBLE 2" 1-1/2" 1/2" 1/2" BATTERY
WALL MOUNTED, AMERICAN STANDARD #0356.421, VITREOUS CHINA, WHITE. SLOAN FAUCET #EBF-85, 0.35 GPM, SENSOR OPERATED. PROVIDE STOPS, SUPPLIES, C.P.

BRASS "P" TRAP, & WATTS WALL SUPPORT #TCA-411.

S-1 SINK 2" 1-1/2" 1/2" 1/2" NA
COUNTER MOUNTED, JUST #SL-ADA 2131-A65-J, 21-1/4"X31"X6-1/2" 18 GA.

STAINLESS, SINGLE BOWL. PROVIDE WITH T&S BRASS FAUCET #S-2770, STRAINER, STOPS, SUPPLIES & C.P. BRASS "P" TRAP.

UR-1 URINAL 2" 1-1/2" 1-1/4" NA BATTERY
WALL MOUNTED, AMERICAN STANDARD PINTBROOK #6002.001, SENSOR OPERATED,

0.125 GPF, 14-7/16"X14-5/16"X22-5/8", VITREOUS CHINA, WHITE. PROVIDE WITHSLOAN "SOLIS" FLUSH VALVE #8186, 0.125 GPF.

WC-1 WATER CLOSET -
ACCESSIBLE 3" 2" 1-1/4" NA BATTERY
FLOOR MOUNTED, AMERICAN STANDARD MADERA #3043.001, ELONGATED, SENSOR OPERATED, 26-3/4"X14"X17" RIM, VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN FLUSH VALVE #8111-1.1-OR, 1.1 GPF AND & BEMIS OPEN FRONT SEAT #1955SSCT-000. INSTALL PER ACCESSIBLE FACILITIES REQUIREMENTS, LOCATE

HANDLE ON WIDE SIDE OF FIXTURE
WC-2 WATER CLOSET 3" 2" 1-1/4" NA BATTERY
FLOOR MOUNTED, AMERICAN STANDARD MADERA #2234.001, ELONGATED, SENSOR OPERATED, 26-3/4"X14"X15" RIM, VITREOUS CHINA, WHITE. PROVIDE WITH SLOAN FLUSH VALVE #8111-1.1-OR, 1.1 GPF AND & BEMIS OPEN FRONT SEAT #1955SSCT-000. LOCATE HANDLE ON WIDE SIDE OF FIXTURE
NOTES: 1. DATA GIVEN IN SCHEDULE PROVIDES CODE REQUIRED FLOW RATES AND MINIMUM BRANCH PIPING SIZES.

2. BRANCH LINE SIZE MINIMUMS ARE TO BE AS SPECIFIED IN THIS CHART UNLESS OTHERWISE NOTED.

CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Lead Sheets.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING SCHEDULES
MP-001

DUCTLESS SPLIT SYSTEM HEAT PUMP SCHEDULE

TAG MAKE NOM
TONS

SENSIBLE

COOLING REFRIGERANT

AHRI PERFORMANCE

INDOOR UNIT OUTDOOR UNIT

REMARKS

SEE BELOW

COOLING HEATING
BTUH SEER2 EER2 BTUH AT 47°F BTUH AT 17°F HSPF2 MODEL INSTALLATION TYPE POWER
V/ɸ/HZ MCA MOCP CFM WATTS
[HP]

OPERATING
WEIGHT
LBS

INSTALLATION
DETAIL MODEL POWER V/ɸ/HZ MCA MOCP

OPERATING
WEIGHT
LBS

INSTALLATION
DETAIL
DAIKIN 1.5 13,700 R-410A 18,000 16.9 11.9 20,000 13,800 7.6 FAQ18TAVJU HIGH WALL 208/1/60 0.5 15 500 43 35 2/MP-002 RZQ18TBVJUA 208/1/60 16.5 20 175 1/MP-002 C1 GENERAL NOTES APPLICABLE TO ALL UNITS:

A. DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR.

B. UNIT SHALL BE CONFIGURED FOR COOLING ONLY.

C. SIZE REFRIGERATION LINES PER THE MANUFACTURERS REQUIREMENTS FOR TOTAL DEVELOPED LINE LENGTH.

D. PROVIDE WITH MANUFACTURERS CONDENSER WALL MOUNTING BRACKET.

CONTROL NOTES:C1. PROVIDE WITH MANUFACTURERS MODEL BRC1E73 WIRED CONTROLLER.

DS
1 VENTILATION CALCULATION
System
Tag Room Name
Room
Area
(SQFT)
Table 120.1-A Occupancy
Category
Table 120.1-A
Area Outdoor Air
Rate (cfm/sqft)
CFM
Requirement:
120.1(c)3
(E)AC Unit That Serves the First Floor
Bureau Sargeant 107 149 Office Buildings - Office space 0.15 23 Shared Office 126 354 Office Buildings - Office space 0.15 54 Open Office 102 1848 Office Buildings - Office space 0.15 278 North Stair 1F 151 General - Corridors 0.15 23
South Stair 1F 151 General - Corridors 0.15 23
Hall (Adjacent to Stairs) 43 General - Corridors 0.15 7 Lobby 100 260 General - Corridors 0.15 39
Hall 114/115 131 General - Corridors 0.15 20
Break Room 121 240 Office Buildings - Breakrooms 0.5 120 Briefing Room 122 806 General - Conference/meeting 0.5 403 Incident Com. 123 125 Office Buildings - Office space 0.15 19 Dispatch 124 86 Office Buildings - Office space 0.15 13 Meeting 125 126 General - Conference/meeting 0.5 63
TOTAL 1085
(E)AC Unit That Serves the Second floor
Int Affairs Lieut. 224 266 Office Buildings - Office space 0.15 40 Break Room 207 244 Office Buildings - Breakrooms 0.5 122 BOS. Manager 208 129 Office Buildings - Office space 0.15 20 Public Affairs Manager
205 134 Office Buildings - Office space 0.15 21
Meeting Room 202 133 General - Conference/meeting 0.5 67 North Stair 2F 154 General - Corridors 0.15 24
South Stairs and Hallway
2F 457 General - Corridors 0.15 69
Train/Hiring Manager 208 132 Office Buildings - Office space 0.15 20 Crime Analyst 209 129 Office Buildings - Office space 0.15 20 Conf. 202 679 General - Conference/meeting 0.5 340
Conf. 202 Hall/Flex
Spaces 646 General - Corridors 0.15 97
Break Room 215 262 Office Buildings - Breakrooms 0.5 131 Chief 214C 452 Office Buildings - Office space 0.15 68
Admin 214A 265 Office Buildings - Office space 0.15 40
Dept. Chief 213 155 Office Buildings - Office space 0.15 24 Dept. Chief 211 139 Office Buildings - Office space 0.15 21 TOTAL 1124
NOTES: AFTER COMPLETION OF CONSTRUCTION AND PRIOR TO OCCUPANCY THE OUTSIDE AIR INTAKE AT THE (E) ACUNITS SHALL BE BALANCED AS FOLLOWS:FIRST FLOOR AC UNIT: BALANCE OUTSIDE AIR INTAKE TO 1100 CFM SECOND FLOOR AC UNIT: BALANCE OUTSIDE AIR INTAKE TO 1125 CFM 1

Page 264 of 1531 ends

CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Lead Sheets.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068 M 340
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING DETAILS
NTS MP-00
2 RETURN AIR GRILLE INTO PLENUM 4
14x12L

DUCT LINER PER

SPECIFICATIONS
24 GAUGE CAN
1/2" GALVANIZED STEEL MESH

SCREEN OVER OPENING

REFER TO DETAIL
3/MP-002 FOR GRILLESUPPORT
NTSDIFFUSER OR GRILLE INSTALLATION (LAY-IN CEILING) 3 (

CEILING GRID

DIFFUSER OR GRILLE
24 GAGE DIFFUSER CAN

DUCT INSULATION PER

SPECIFICATIONS
2" WIDE, 4" LONG 24 GAUGE CLIP

SECURED TO DIFFUSER CAN WITH
#12 TEK SCREW
#12 SLACK SAFETY WIRE AT
DIAGONAL CORNERS WITH (4) TIGHT
TURNS IN 11
2"

DUCT INSULATION PER

SPECIFICATIONS

CONICAL FITTING WITH BEAD FOR
FLEXIBLE DUCT CONNECTIONFLEXIBLE DUCT 60" MAX LENGTH,REFER TO DETAIL 5/MP-002 FOR

ATTACHMENT
24 GAGE

DIFFUSER CAN

ATTACH DIFUSER OR GRILLE TO
CAN WITH (8)#12 TEK SCREWS (2)

PER SIDE EQUALLY SPACED
#12 SLACK SAFETY

WIRE REFER TO

ARCHITECTURAL

DETAILS FOR UPPER

CONNECTION
1 1 MIN
MINIMUM 2" LONG COLLAR WITHBEAD FOR FLEXIBLE DUCT

CONNECTION

ADAPTER TO NECK
SIZE
1-1/2 RADIUS
ELBOW

SIDE DUCT CONNECTION

TOP DUCT CONNECTION

DUCT INSULATION PER

SPECIFICATIONS
TOP DUCT CONNECTION SHALL BE USED WHERE SPACE PERMITS. ONLY USE SIDE DUCT CONNECTION WHERE VERTICAL CLEARANCE IS LIMITED.

DIFFUSER SUPPORT NOTES ARE APPLICABLE TO BOTH DUCT

CONNECTION CONFIGURATIONS
NTSHIGH WALL FAN COIL MOUNTING 2

MOUNTING BRACKET

SUPPLIED WITH UNIT, MOUNT

TO BLOCKING IN WALL WITH
(9) M8 WOOD SCREWS
MINIMUM 1-1/2" EMBEDMENT

INTO BLOCKING

CONDENSATE DRAIN IF NOT
PUMPED

REFRIGERATION LINES

AND CONDENSATE

DRAIN WHEN PUMPED

STUD (TYP)
4x4 BLOCKING IN WALL
(TYP)

OUTLINE OF FAN COILOUTLINE OF FAN COIL
35 LBS MAX
NTSFLEXIBLE DUCT CONNECTION 5

STAINLESS STEEL

WORM GEAR CLAMP
OVER (2) WRAPS OF
UL-181 DUCT TAPE
STEP - 1:

FOLD BACK JACKET AND INSULATION. SLIDE AT LEAST 1" OF CORE OVER DUCT AND PAST THE BEAD. SEAL CORE TO DUCT WITH AT LEAST (2) WRAPS OF UL-181 LISTED DUCT TAPE.

SECURE CONNECTION WITH A CLAMP PLACED OVER THE CORE AND TAPE PAST THE BEAD.

OUTSIDE JACKET

INSULATION

WIRE HELIX AND LINING
CORE

OUTSIDE JACKET

INSULATION

OUTSIDE JACKET

INSULATION

WIRE HELIX AND LINING
CORE

WIRE HELIX AND LINING
CORE
STEP - 2:

PULL THE INSULATION AND JACKET OVER THE TOP OF THE CORE AND THE CLAMP. TUCK THE OUTSIDE JACKET UNDER THE INSULATION.

STEP - 3:

INSTALL A CLAMP AROUND THE ENTIRE FLEXIBLE DUCT ASSEMBLY

STAINLESS STEEL

WORM GEAR CLAMP

DUCTDUCTDUCT
24" MIN
NTSROUND VOLUME DAMPER 6

WING NUT

DAMPER REGULATOR SET
10"Ø AND SMALLER: NO.KSR12"Ø TO 20"Ø: NO.KSR
21"Ø AND LARGER: NO.KS-12
ALL SETS TO BE "QUADRANT" TYPE
HANDLE

DUCT PENETRATIONS SHALL BE
SEALED AIR TIGHT. ALL MODEL
NUMBERS LISTED ARE DURO DYNE.
1/8" CLEARANCE BETWEEN DAMPER

AND DUCT ALL AROUND

ROD CONTINUOUS ON ALL DAMPERS
OVER 10"Ø

DAMPER, OPPOSED BLADE OR SINGLELEAF TYPE
OUTSIDE CLOSED END BEARING NO.

SB, SIZE AS REQUIRED
PLAN

ELEVATION
WALL
ESCUTCHEON (TYP.)
'P'- TRAP
HOSE CLAMP (TYP.)

WYE BRANCH TAILPIECE
SINK
NTSCONDENSATE TO TAIL PIECE DETAIL 7

ALL CONDENSATE PIPING

SHALL BE TYPE L COPPER
AND INSULATED WITH 1/2"

INSULATION

NEOPRENE HOSE SAME SIZE

AS CONDENSATE DRAIN

CONDENSATE DRAIN LINE IN WALL
NTSHIGH-WALL FANCOIL CONDENSATE DRAIN 8

CEILING

HIGH-WALL FANCOIL UNIT

CONDENSATE PUMP WITH INTEGRAL CHECK VALVE,

REFER TO MECHANICAL PLANS

ADAPTOR AS REQUIRED

COPPER FEMALE THREADED ADAPTOR
WALL

HEIGHT SHALL NOT EXCEED

HEAD CAPABILITY OF PUMP
12"MINCONNECT TO TOP OF GRAVITY DRAINED CONDENSATE PIPE (TYP)

SLOPE TO DRAIN, REFER TO PLANS FOR SIZE

WALL PENETRATION BEHIND FANCOIL UNIT,

DO NOT RUN PIPING EXPOSEDPROVIDE OPEN VENT ON UPPERMOSTUNIT IN ACCESSIBLE LOCATION

ALL CONDENSATE PIPING

SHALL BE TYPE L COPPER
AND INSULATED WITH 1/2"

INSULATION
NTSCONDENSING UNIT - WALL MOUNTING BRACKET 1

CONDENSER
3'' MIN. (E) CMU

PARAPET WALL
1/4" DIA. 'TITEN

HD SS' ANCHOR,
MIN 2-1/2"

EMBEDMENT
(TYP OF 2 EACH

BRACKET)
(MAX WEIGHT
175 LBS)
40" MAX
4" MIN
12" MIN
8" MIN VERIFY IN FIELD

EPDM GASKET
1/2" ROUND,
3/32" THICK,

FLAT SS
WASHER

MOUNTING LEG

INTEGRAL TO

CONDENSING UNIT

MOUNTING BRACKET
(TYP OF 2)
FASTEN

CONDENSER WITH

HARDWARE

PROVIDED WITHMOUNTING BRACKET
(E) SINGLE PLY

ROOFING
(E) SINGLE PLY

ROOF SURFACE

Page 265 of 1531 ends

CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Lead Sheets.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

ENERGY COMPLIANCE DOCUMENTATION
E
C-000

Page 266 of 1531 ends

UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 U
C C
1717
(E)18Ø
(E)14Ø
(E)14Ø
(E)S (E)S (E)S
(E)S

POD (E)R (E)R (E)R (E)R
1 1 1
1 1 1
1 2
3 4
(E)E 150(E)E 150(E)S 100(E)S 100
1111
7777
(E)R 1
5 6 5
1 MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN SCALE:1/8" = 1'-0"

DEMOLITION KEY NOTES

APPLICABLE TO THIS SHEET ONLY
GRILLE/DIFFUSER TO BE REMOVED AND DISCARDED.

REMOVE ALL DUCTWORK UPSTREAM OF POD.
(E) LAV TO BE REMOVED. PIPING TO REMAIN.(E) URINAL TO BE REMOVED. CAP PIPING IN WALL.(E) FIXTURE TO BE REMOVED. PIPING TO REMAIN.

REMOVE (E) STAND PIPE AND ASSOCIATED STOPS. CAP PIPING UNDER CABINET.

DISCONNECT DUCT FROM GRILLE/DIFFUSER. CAP DUCT TO KEEP CLEAN UNTIL RECONNECTION TO NEW GRILLE/DIFFUSER.
1234567

DEMOLITION PLAN STATEMENT

THIS DEMOLITION PLAN WAS PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND

THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND

RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. DISPOSE OF ALL EQUIPMENT PER THE OWNER'S DIRECTION WHILE COMPLYING WITH ALL LOCAL CODES AND ORDINANCES.

ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE. CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Plan.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068 M 340
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING DEMOLITION FIRST FLOOR PLAN
MPD-101

Page 267 of 1531 ends

T
(E)S 650 (E)S 650
(E)S 325 (E)S 250
(E)18Ø
(E)14Ø
(E)18Ø
(E)S 100
(E)10Ø (E)6Ø
(E)10Ø
(E)10Ø
(E)14Ø
UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
POD
POD
(E)R
POD
(E)R
1 2
1 1
1 2
1 3
(E)R
(E)E 200
(E)S 150
(E)S 200
(E)R
(E)E 250
11111
1 444
4 5
6 6
6 66
6 6
6 1 MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN SCALE:1/8" = 1'-0"

DEMOLITION KEY NOTES APPLICABLE TO THIS SHEET ONLY
GRILLE/DIFFUSER TO BE REMOVED AND DISCARDED.

REMOVE ALL DUCTWORK UPSTREAM OF POD.
(E)FIXTURE TO BE REMOVED. CAP PIPING IN WALL AND BELOW FLOOR.

DISCONNECT DUCT FROM GRILLE/DIFFUSER. CAP DUCT TO KEEP CLEANUNTIL RECONNECTION TO NEW GRILLE/DIFFUSER (E)EXHAUST FAN TO BE REMOVED. DISCONNECT FROM POWER AND DUCTWORK. CAP DUCT AIR TIGHT.
(E) FIXTURE TO BE REMOVED. PIPING TO REMAIN.
123456

DEMOLITION PLAN STATEMENT

THIS DEMOLITION PLAN WAS PREPARED FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER DOES NOT REPRESENT THAT ALL ITEMS WHICH MAY REQUIRE DEMOLITION HAVE BEEN SHOWN. IT SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY EXAMINE THE SITE AND

THE CONTRACT DOCUMENTS AND TO PERFORM ALL DEMOLITION AND

RECONSTRUCTION WHICH MAY BE REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. DISPOSE OF ALL EQUIPMENT PER THE OWNER'S DIRECTION WHILE COMPLYING WITH ALL LOCAL CODES AND ORDINANCES.

ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE. CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Plan.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068 M 340
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING DEMOLITION SECOND FLOOR PLAN
MPD-1
0 2

Page 268 of 1531 ends

1 1
A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717

MEETING
125

DISPATCH
124
LOBBY
100

STORAGE
111
SHARED
OFFICE
126
BUREAU

SERGEANT
107

DETECTIVE

EQUIPMENT
106

DRONE/EQUIP

STORAGE
105 OPEN OFFICE
102
MEN
118
JAN.
117
HALL
115
WOMEN
119
BREAK
ROOM
121

ELECTRICAL
120

INCIDENT
COM.
123

BRIEFING
ROOM
122

ELEVATOR LEVAT
127
(E)18Ø
(E)14Ø
POC
(E)R
S1 450
15x15 S1 450
15x15 (E)S 600
12Ø 14Ø
12Ø
(E)14Ø
R1 22x22
HALL
114

STORAGE
STAIR
HALL
139 2 DF-1
E1 150 12x12E1 150 12x12S1 100
6x6
S1 100
6x6
3333
STAIR
123

TYPICAL VOLUME
DAMPER, REFER TODETAIL 6/MP-002
R1 22x22
R1 22x22
LAV-1
WC-1
WC-1
LAV-1
1 MECHANICAL & PLUMBING FIRST FLOOR PLAN SCALE:1/8" = 1'-0"

KEY NOTES APPLICABLE TO THIS SHEET ONLY
CONNECT NEW FIXTURE WITH EXISTING PIPING IN WALL. 1/2" HOT AND COLD WATER, 1-1/2" VENT AND 2" WASTE.

CONNECT NEW FIXTURE WITH EXISTING PIPING IN WALL. 1/2" COLD WATER, 1-1/2" VENT AND 2" WASTE.

CONNECT (E) DUCT TO NEW GRILLE/DIFFUSER.

GENERAL NOTES APPLICABLE TO THIS SHEET ONLY
1 ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE.
2 NEW FLEXIBLE DUCT SHALL NOT EXCEED 60" IN LENGTH. EXTEND EXISTINGRIGID DUCT AS NECESSARY TO MAKE THE FLEXIBLE DUCT CONNECTION TO THE DIFFUSER NO MORE THAN 60" LONG.
3 SEE PLUMBING FIXTURE SCHEDULE FOR BRANCH PIPE SIZING. 4 PROVIDE ANGLE STOPS FOR ALL PLUMBING FIXTURE BRANCH PIPING LINES. 5 REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF FIXTURES,

INCLUDING BUT NOT LIMITED TO FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, ROOF DRAINS, ETC.
6 AFTER COMPLETION OF THE DUCTWORK MODIFICATIONS, BALANCE THE SHOWN AIR DISTRIBUTION TO THE VALUES LISTED.
123
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Plan.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068 M 340
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING FIRST FLOOR PLAN
MP-200

Page 269 of 1531 ends

UP
UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 U
C C
1717
BREAK
ROOM
215
SERVER
216
PANTRY
216
CHIEF
214C
ADMIN
214A
DEPT.

CHIEF
213
DEPT.

CHIEF
211
COPY
ROOM
210

ELEV MECH
112

ELEVATOR
131
CONF.
202

MEETING
ROOM
202
PUBLIC

AFFAIRS MANAGER
205
BOS.

MANAGER
206
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
JAN
223
WOMENS
222
HALL
149
EQUIP.
220

TRAIN/HIRING

MANAGER
208
CRIME

ANALYST
209
T
S1 600
15x15
(E)S 250
(E)18Ø
(E)14Ø
(E)18Ø
(E)S 100
(E)10Ø (E)6Ø
(E)10Ø
(E)10Ø
(E)14Ø
POC
14Ø
S1 625
15x15
S1 400
15x15
POC
POC
R1 22x22
R1 22x22
1 WC-2
STAIRS
144
T
2 DS
1 ODU ON
ROOF
DS
1 IDU

ON WALL ABOVE DOOR
E1 200 12x12
S1 150
9x9
S1 200
9x9
E1 250 12x12
333
3 REFRIGERANT

PIPING DN FRM
ROOF
WC-1
LAV-1
WC-1
WC-2
WC-2
LAV-1
LAV-1
DS-1
IMS-1
S-1
1/2"CW DOWN

IN WALL
4 UR-1
STAIRS
152
6 POC
1 MECHANICAL & PLUMBING SECOND FLOOR PLAN SCALE:1/8" = 1'-0"

KEY NOTES

APPLICABLE TO THIS SHEET ONLY
CONNECT NEW FIXTURE WITH EXISTING PIPING. 3/4" COLD WATER, 2" VENT AND 3" WASTE.
3/4" CD DN SERVER ROOM WALL. CONNECT TO SINK TAILPIECE PER DETAIL7/MP-002.

CONNECT (E) DUCT TO NEW GRILLE/DIFFUSER.CONNECT 1/2"CW TO (E) CW. PLUMBER TO FIELD VERIFY EXACT LOCATIONOF PIPING. 3/4" CONDENSATE CONNECTION TO MECHANICAL EQUIPMENT. SEE DETAIL 8/MP-002 FOR MORE INFORMATION.

SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION.

GENERAL NOTES

APPLICABLE TO THIS SHEET ONLY
1 ALL EXISTING ITEMS SHOWN ON THE PLANS HAS BEEN COLLECTED FROM THE BEST AVAILABLE RESOURCES. ACCURACY AND LOCATION OF EXISTING ITEMS MAY NOT BE ACCURATE.
2 NEW FLEXIBLE DUCT SHALL NOT EXCEED 60" IN LENGTH. EXTEND EXISTINGRIGID DUCT AS NECESSARY TO MAKE THE FLEXIBLE DUCT CONNECTION TO THE DIFFUSER NO MORE THAN 60" LONG.
3 SEE PLUMBING FIXTURE SCHEDULE FOR BRANCH PIPE SIZING. 4 PROVIDE ANGLE STOPS FOR ALL PLUMBING FIXTURE BRANCH PIPING LINES. 5 REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF FIXTURES,

INCLUDING BUT NOT LIMITED TO FLOOR SINKS, FLOOR DRAINS, TRENCH DRAINS, ROOF DRAINS, ETC.
6 AFTER COMPLETION OF THE DUCTWORK MODIFICATIONS, BALANCE THE SHOWN AIR DISTRIBUTION TO THE VALUES LISTED.
123456
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.DESIGNED BY:DRAWN BY:CHECKED BY:APPROVED BY:SCALE:PLAN FILE NO. / LOCATION S:\Shared\Jobs\ENG Projects\SLO PD North Building TI\Engineering\SLO PD North Building TI Mechanical and Plumbing Plan.dwg khanjiev Sep 13,2024-9:57am AS INDICATED 05/14/2024 2000577-04
BY 3C Engineering, Inc., ALL COMMON LAW

COPYRIGHT AND OTHER PROPERTY RIGHTS

RESERVE THIS DOCUMENT AS AN ORIGINAL AND
UNPUBLISHED WORK PRODUCT. THIS WORK SHALL

NOT BE DUPLICATED, COPIED, DISCLOSED OR USED

IN CONNECTION WITH ANY WORK OR PROJECT

OTHER THAN THE SPECIFIC PROJECT FOR WHICH IT

HAS BEEN PREPARED, NOR SHALL IT BE ASSIGNED

TO ANY THIRD PARTY WITHOUT FIRST OBTAINING

THE EXPRESS WRITTEN CONSENT OF VISUAL
CONTACT. THIS DOCUMENT SHALL CONSTITUTE

CONCLUSIVE EVIDENCE OF ACCEPTANCE OF
THESE RESTRICTIONS.

R E G I S T E R E D P RO F E S S I ON A L E NG I N E E R B R I A N P. S T A R R E T T

S T A T E OF CA L I FORN I A

M E C H A N I C A L
EXP 6/30/26 . 6/30/26
M 34068 M 340
DSKHBS
1106 WALNUT TENANT IMPROVEMENT

MECHANICAL & PLUMBING SECOND FLOOR PLAN
MP-300

Page 270 of 1531 ends

San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - C:\Users\chris\appdata\local\temp\AcPublish_27704\24-8026_E-001 - ELECTRICAL GENERAL NOTES.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT

1. CODE COMPLIANCE: ALL WORK SHALL CONFORM TO AND BE PERFORMED IN ACCORDANCE WITH CODES,

STANDARDS, AND ORDINANCES AS SET FORTH BY THE AUTHORITIES HAVING JURISDICTION AND THEIR LATEST ADOPTED EDITIONS (IN EFFECT AT TIME OF BUILDING PERMIT APPLICATION) OF THE FOLLOWINGPUBLICATIONS:

A. ALL WORK SHALL COMPLY WITH 2020 NATIONAL ELECTRICAL CODE (NEC) AS AMENDED BY THE 2022 CALIFORNIA ELECTRICAL CODE (CEC), 2022CALIFORNIA BUILDING CODE (CBC), 2022 CALIFORNIA ENERGY CODE (CEnC), CALIFORNIA FIRE CODE (CFC), 2022 CALIFORNIA MECHANICAL CODE (CMC), 2022 CALIFORNIA GREEN BUILDING STANDARDS (CGBC), AND ADOPTED ORDINANCES.

B. AMERICANS WITH DISABILITIES ACT (ADA).

2. SAFETY: THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN ALL EQUIPMENT IN A SAFE AND RESPONSIBLE MANNER. KEEP DEAD FRONT EQUIPMENT IN PLACE WHILE EQUIPMENT IS ENERGIZED.

CONDUCT ALL CONSTRUCTION OPERATIONS IN A SAFE MANNER FOR EMPLOYEES AS WELL AS OTHER WORKPERSONS OR ANYONE VISITING THE JOB SITE. PROVIDE BARRIERS, FLAGS, TAPE, ETC. AS REQUIRED FOR SAFETY. THE CONTRACTOR SHALL HOLD ALL PARTIES HARMLESS OF NEGLIGENT SAFETY PRACTICES, WHICH MAY CAUSE INJURY TO OTHERS ON OR NEAR THE JOB SITE.

3. FIRE RATED ASSEMBLIES SHALL MAINTAIN RATINGS AS SPECIFIED IN THE CALIFORNIA BUILDING CODE CHAPTER 7. CONTRACTOR SHALL PROVIDE AND INSTALL PHYSICAL ENCLOSURE AROUND FIXTURES, PANELS, ETC. AS REQUIRED. ALL ASSEMBLIES TO BE PENETRATED SHALL BE INSTALLED WITH APPLICABLE THROUGH-PENETRATION FIRESTOP SYSTEM AS DETERMINED BY UL CLASSIFICATION.

BEFORE CONSTRUCTION, VERIFY AND COMPLY WITH REQUIREMENTS OF LOCAL AUTHORITY HAVING JURISDICTION.

4. MOUNTING HEIGHTS SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED:
+15" AFF: RECEPTACLES, TELEPHONE, TV & DATA OUTLETS. (MEASURED BOTTOM OF OUTLET BOX)+46" AFF: OUTLET ABOVE COUNTER (MEAUSRED TOP OF OUTLET BOX)+48" AFF: LIGHT SWITCHES. (MEASURED TOP OF OUTLET BOX)+48" AFF: FIRE ALARM MANUAL PULL STATIONS, T-STATS. (MEASURED TOP OF OUTLET BOX) THE LOWER OF +80" AFF TO BOTTOM OF LENS, OR 6" BELOW CEILING: FIRE ALARM VISUALS.

ELECTRICAL SWITCHES: CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THEROOM OR AREA TO CONTROL LIGHT AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM. [CBC 11B-308.1.1] ELECTRICAL RECEPTACLE OUTLETS: ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48

INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISH FLOOR OR WORKING PLATFORM [CBC 11B-308.1.2]

CONTROLS AND OPERATING MECHANISMS SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 11B-309.

BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT ELECTRICAL CONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, ETC. WITH ARCHITECT OR OWNER.

PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. AND IN BATHROOMS SO AS NOT TO CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS SHALL GOVERN.

5. LABEL PANELS, CABINETS, BACKBOARDS, MAIN DEVICES, SAFETY SWITCHES, CONTACTORS AND OTHER SPECIFICALLY DESIGNATED EQUIPMENT SHOWN ON PLANS. USE ENGRAVED LAMINATED PLASTIC NAMEPLATES ATTACHED BY SCREWS OR RIVETS. FOR FEEDERS, NEATLY AND INDELIBLY LABEL CONDUITDESTINATIONS ON BOTH VISIBLE ENDS OF CONDUIT RUNS WHERE CONDUITS TERMINATE AT DESIGNATED ENCLOSURES, STRUCTURES OR EQUIPMENT (INCLUDING PULL AND SPLICE BOXES).

5. EQUIPMENT ANCHORAGE NOTE

ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE ANCHORED OR BRACED TO MEET THE HORIZONTAL AND VERTICAL FORCES PRESCRIBED IN THE 2022 CBC, SECTIONS 1617A.1.18 THROUGH 1617A.1.26, AND ASCE 7-15 CHAPTERS 13, 26, AND 30 AND 2022 CEC 110.3(B)

THE ATTACHMENT OF THE FOLLOWING ITEMS SHALL BE DESIGNED TO RESIST THE FORCES PRESCRIBED ABOVE, BUT NEED NOT BE DETAILED ON THE PLANS PER 2022 CBC SECTION 1616A.1.18:

A. FURNITURE(EXCEPT STORAGE CABINETS AS NOTED IN 2022 CBC TABLE 13.5-1) B. TEMPORARY OR MOVABLE EQUIPMENT WITH EXCEPTIONS NOTED IN 2022 CBC SECTION 1616A.1.18 ITEM 2.

C. ARCHITECTURAL, MECHANICAL, AND ELECTRICAL COMPONENTS IN SEISMIC DESIGN CATEGORIES D,

E, OR F
THAT MEET ALL OF THE CRITERIA LISTED IN 2022 SECTION 1616A.1.18 ITEM 3.

D. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUPPORTED BY VIBRATION ISOLATORS.

E. EQUIPMENT WEIGHING LESS THAN 20 POUNDS SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A
WALL

FOR THOSE ELEMENTS THAT DO NOT REQUIRE DETAILS ON THE APPROVED DRAWINGS, THE INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE MECHANICAL/ELECTRICAL ENGINEER.

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTEPIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-16, SECTION 13.3 AS DEFINE IN ASCE 7-16 SECTIONS

13.6.5, 13.6.6, 13.6.7, 13.6.8, AND 2022 CBC, SECTIONS 1617A.1.24, 1617A.1.25, AND 1617A.1.26.

6. THE ISSUANCE OF A PERMIT SHALL NOT PREVENT THE BUILDING OFFICIAL FROM REQUIRING

THE CORRECTION OF ERROS ON THESE PLANS OR FROM PREVENTING ANY VIOLATION OF THE CODES ADOPTED BY THE CITY, RELEVANT LAWS, ORDINANCES, RULES AND/OR REGULATIONS.

GENERAL NOTES
A. FUSING: ALL FUSIBLE SAFETY DISCONNECT SWITCHES SHALL BE PROVIDED WITH DUAL-ELEMENT TIME DELAY TYPE FUSES SIZED AND RATED PER EQUIPMENT MANUFACTURERS' RECOMMENDATIONS. VERIFY WITH EQUIPMENT NAMEPLATE BEFORE INSTALLATION.

B. INSTALL SEPARATE NEUTRALS FOR EACH 120V BRANCH CIRCUIT.

C. MOTOR OVERLOAD PROTECTION: WHERE REQUIRED BY NEC ARTICLE 430 PART C AND NOT SHOWN ON PLAN

OR PROVIDED INTEGRAL WITH EQUIPMENT, PROVIDE AND INSTALL THERMAL OVERLOAD PROTECTION FOR ALL MOTORS.

D. SPARE CONDUIT FOR RECESSED PANELS: PROVIDE (1) 3/4" SPARE CONDUIT STUB UP TO ACCESSIBLE ABOVE CEILING SPACE AND/OR ACCESSIBLE SPACE BELOW FOR EVERY (3) SPARE BREAKER SPACES AS INDICATEDON PANEL SCHEDULES.

E. DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD

VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT.

F. ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION, SHALL BE MOUNTED ON OPPOSITE SIDES OF THE SAME STUD. COORDINATE BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS.

G. ALL NEW OUTLETS MUST BE TAMPER PROOF.

H. ALL 15 AND 20AMPERE RECEPTACLES FOR BOTH DAMP AND WET LOCATIONS REQUIRED TO BE LISTED WEATHER-RESISTANT (WR) TYPE PER CEC 406.9 (A) AND (B)
I. CEC 406.9(A) RECEPTACLES IN DAMP LOCATIONS: RECEPTACLES INSTALLED OUTDOORS IN A LOCATION

PROTECTED FROM THE WEATHER OR IN OTHER DAMP LOCATIONS SHALL BE AN ENCLOSURE FOR THERECEPTACLE THAT IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT PLUG CAP NOT

INSERTED AND RECEPTACLE COVERS CLOSE)
J. CEC 406.9(B) RECEPTACLES OF 15 AND 20AMP, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL

HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BEIDENTIFIED AS 'EXTRA-DUTY" OTHER LISTED PRODUCTS, ENCLOSURES, OR ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO NOT UTILIZE AN OUTLET BOX HOOD NEED TO BE MARKED "EXTRA DUTY"EXCEPTION: 15 AND 20AMP, 125 THROUGH 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION AND

SUBJECT TO ROUTINE HIGH-PRESSURE SPRAY WASHING SHALL BE PERMITTED TO HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHEN THE ATTACHMENT PLUG IS REMOVED.

A. NIGHT LIGHT "NL" DESIGNATED LUMINAIRES IN INTERIOR LOCATIONS SHALL HAVE ONE BALLAST CONTINUOUSLY ENERGIZED. LUMINAIRES IN EXTERIOR LOCATIONS SHALL BE AUTOMATICALLY CONTROLLED TO BE ON FROM DUSK TO DAWN.

B. LIGHTING FIXTURE LOCATIONS SHOWN ARE SCHEMATIC. REFER TO ARCHITECTURAL PLANS (REFLECTED CEILING, ELEVATIONS, ETC.) FOR EXACT LOCATIONS AND MOUNTING HEIGHTS PRIOR TO ROUGH-IN.

C. REFER TO ARCHITECT'S REFLECTED CEILING PLAN(S) FOR CEILING HEIGHTS, TYPES, FINISHES, ETC. IN EACH AREA. VERIFY FLANGE TYPES, TRIM KITS, STEM LENGTHS, ETC. FOR ALL FIXTURES PRIOR TO SUBMITTALS.

D. CONFIRM LOCATION OF ALL DOORS SWINGS WITH ARCHITECTURAL PLANS PRIOR TO ROUGH-IN OF SWITCHES.

E. PROVIDE UNSWITCHED HOT LEG OF ROOM LIGHTING BRANCH CIRCUIT TO EACH BATTERY POWERED EMERGENCY LIGHT AND EXIT SIGN FOR CONTINUOUS CHARGING.

LIGHTING FLOOR PLAN

RATED WALLS/ASSEMBLIES NOTES
SHEET NO. SHEET DESCRIPTION
E-001 ELECTRICAL GENERAL NOTES
E-002 ELECTRICAL LEGEND AND ABBREVIATIONSE-003 ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES ED-101 FIRST FLOOR POWER AND SIGNAL DEMOLITION PLAN
ED-102 SECOND FLOOR POWER AND SIGNAL DEMOLITION PLAN
E-101 FIRST FLOOR POWER AND SIGNAL PLAN
E-102 SECOND FLOOR POWER AND SIGNAL PLAN
E-111 FIRST FLOOR LIGHTING PLANS
E-112 SECOND FLOOR LIGHTING PLANSE-113 LIGHTING EMERGENCY PHOTOMETRIC PLANS E-121 ELECTRICAL ROOF PLANE-201 ELECTRICAL DETAILSE-301 TITLE 24 ENERGY FORMS - INTERIOR LIGHTING

ELECTRICAL SHEET INDEX

POWER FLOOR PLAN

1. IN FIRE-RESISTANCE RATED WALLS, DETAIL THROUGH PENETRATIONS AND MEMBRANE PENETRATION PER CBC 714.4 AS NOTED BELOW:

A. STEEL, FERROUS OR COPPER PIPES MAY PENETRATE FIRE-RESISTANCE RATED WALLS, PROVIDED THE OPENING IS PROTECTED AS FOLLOWS: (CBC 714.4.1)
i. ITEM PENETRATING CONCRETE OR MASONRY WALLS IS A MAXIMUM 6 INCHES NOMINAL DIAMETER AND THE AREA OF THE OPENING THROUGH THE WALL DOES NOT EXCEED 144 SQUARE INCHES,

CONCRETE, GROUT OR MORTAR IS PERMITTED WHERE IT IS INSTALLED THE FULL THICKNESS OF THE WALL OR THE THICKNESS REQUIRED TO MAINTAIN THE F IRE-RESISTANCE RATING; OR ii. WHEN THE ANNULAR SPACE IS PROTECTED WITH MATERIAL THAT MEETS ASTM E 119 OR UL 263.

B. PENETRATIONS SHALL BE FIRE-STOPPED BY A SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479, AND SHALL HAVE AN F RATING OF NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE WALL PENETRATED. (CBC 714.4.1.2) C. MEMBRANE PENETRATIONS OF MAXIMUM 2-HOUR FIRE-RESISTANCE RATED WALLS BY STEEL ELECTRICAL BOXES ARE PERMITTED, PROVIDED THAT EACH DOES NOT ESCEED 16 SQUARE INCHES IN AREA AND THE TOTAL AREA OF SUCH OPENING DOES NOT EXCEED 100 SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL AREA, AND THE SPACE BETWEEN THE WALL MEMBRANE AND THE BOX DOES NOT EXCEED 1
8 INCH. ADDITIONALLY, OUTLET BOXES ON OPPOSITE SIDES OF THE WALL SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES (CBC 714.4.2 EXCEPTION 1).

D. MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY MATERIAL ARE PERMITTED,

PROVIDED SUCH BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE RATED ASSEMBLIES, AND THE SPACE BETWEEN THE WALL MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCH UNLESS LISTED OTHERWISE. ADDITIONALLY, OUTLET BOXES ON OPPOSED SIDES OF THE WALL SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF NOT LESS THAN 24 INCHES. (CBC 714.4.2 EXCEPTION 2) E. A FIRE SPRINKLER SHALL BE PERMITTED TO BE UNPROTECTED PROVIDED SUCH SPACE IS COVERED BY A METAL ESCUTCHEON PLATE. (CBC 714.4.2 EXCEPTION 5)
F. WHERE WALLS ARE PENETRATED BY OTHER MATERIALS OR OPENINGS LARGER THAN THOSE MENTIONED ABOVE, THEY MUST BE QUALIFIED BY TEST IN ACCORDANCE WITH CBC 714.4.2 EXCEPTION 2.

2. IN FIRE-RESISTANCE HORIZONTAL ASSEMBLIES , DETAIL THROUGH PENETRATIONS AND MEMBRANE PENETRATION PER CBC 714.5 AS NOTED BELOW:

A. STEEL, FERROUS OR COPPER CONDUITS MAY PENETRATE FIRE-RESISTANCE RATED FLOOR ASSEMBLY WHEN THE ANNULAR SPACE IS PROTECTED WITH MATERIAL THAT MEETS ASTM E 119 OR UL 263 (CBC 714.5.1 EXCEPTION 1)
B. PENETRATING ITEMS, AS NOTED ABOVE, WITH A MAXIMUM 6 INCHES NOMINAL DIAMETER SHALL NOT

BE LIMITED TO THE PENETRATION OF A SINGLE FIRE-RESISTANCE RATED FLOOR ASSEMBLY, PROVIDED THAT THE AREA OF THE OPENINGS DOES NOT EXCEED 144 SQUARE INCHES IN ANY 100 SQUARE FEET OF FLOOR AREA. (CBC 714.4.1.1 EXCEPTION 1)
C. PENETRATIONS SHALL BE FIRE-STOPPED BY A SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 OR UL 1479. THE SYSTEM SHALL HAVE AN F RATING AND T RATING OF NOT LESS THAN 1-HOUR BUT NOT LESS THAN THE REQUIRED FIRE-RESISTANCE RATING OF THE FLOOR PENETRATED (CBC 714.5.1)
D. MEMBRANE PENETRATIONS BY LISTED ELECTRICAL OUTLET BOXES ARE PERMITTED PROVIDED SUCH BOXES HAVE BEEN TESTED FOR USE IN FIRE-RESISTANCE RATED ASSEMBLIES, AND THE SPACEBETWEEN THE CEILING MEMBRANE AND THE BOX DOES NOT EXCEED 1/8 INCHESUNLESS LISTED OTHERWISE. (CBC 714.5.2 EXCEPTION 4)
E. A FIRE SPRINKLER SHALL BE PERMITTED TO BE UNPROTECTED PROVIDED SUCH SPACE IS COVERED BY A METAL ESCUTCHEON PLATE. (CBC 714.5.2 EXCEPTION 5)

3. JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALL, FLOOR OR FLOOR/CEILING ASSEMBLIES

AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED AN APPROVED FIRE-RESISTANT JOINT

SYSTEM WITH A FIRE-RESISTANCE RATING NOT LESS THAN THAT OF THE ASSEMBLY IN WHICH IT IS INSTALLED. PROVIDE DETAILS (CBC 7145.1)

4. FIRE DOORS AND FIRE-PROTECTION RATED GLAZING SHALL BEAR LABELS AS REQURIED BY CBC 716.2.9 AND 716.3.5.

5. FIRE DAMPERS SHALL BE THE MINIMUM FIRE PROTECTION RATING SPECIFIED IN CBC TABLE 717.3.2.1 FOR THE TYPE OF PENETRATION (CBC 717.3.2.1)

6. PROVIDE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS SHALL BE PROVIDE AS PRESCRIBED IN CBC 717.

REFER TO SPECIFICATIONS 26 0519 FOR ADDITIONAL INFORMATION.

1. WIRE CONNECTORS SHALL BE MINIMUM 75 DEGREE CENTIGRADE RATED AND PROPERLY SIZED FOR THE NUMBER OF CONDUCTORS BEING CONNECTED, TERMINATED, SPLICED, ETC. ALL ABOVE GRADE

CONNECTORS SHALL BE SOLDERLESS LUG OR PLASTIC WIRE NUT TYPE, SCREW ON, PRESSURE CABLE TYPE (WIRE UT OR SPRING NUT TYPE) 600 VOLT, 105 DEGREE C, WITH SKIRT TO COVER ALL PORTIONS OF STRIPPED WIRES. CONNECTOR SHALL BE U.L. RATED FOR NUMBER AND SIZE OF CONDUCTORS BEING JOINED TOGETHER AS SPLICED.

2. WIRES AND CABLES FOR LINE VOLTAGE SYSTEM AND CONTROLS. WIRE AND CABLE SHALL BE COPPER, 600 VOLT RATED THROUGH OUT. CONDUCTORS 14AWG OT 10AWG, SOLID OR STRANDED. CONDUCTORS 8 AWG

AND LARGER, STRANDED

3. ALL CONDUCTORS SHALL BE COPPER UNLESS OTHERWISE NOTED. MINIMUM SIZE FOR INDIVIDUAL CONDUCTORS SHALL BE #12 AWG UNLESS OTHERWISE NOTED ON PANEL SCHEDULE OR PLANS. SIZE #8 AWG AND LARGER SHALL BE STRANDED CONDUCTOR. INDIVIDUAL CONDUCTORS SHALL BE INSULATED WITH TYPE, XHHW, THW, THHN/THWN 600 VOLT INSULATION UNLESS OTHERWISE NOTED.

4. PROPER INSULATION TYPE SHALL BE USED FOR THE PROPER ENVIRONMENTAL APPLICATION (I.E.

WATERPROOF, WET LOCATION, PLENUM TEMPERATURE RATED). ALL CONDUCTORS, WIRING CABLE WHERE

INSTALLED BELOW FLOOR, SLAB OR UNDERGROUND SHALL BE CONSIDERED WET LOCATIONS, AND SHALL BE RATED ACCORDINGLY. NON WATERPROOF CABLING IS NOT ALLOWED IN ANY BELOW GRADE OR WET APPLICATION.

5. GROUP THE COMMON NEUTRAL CONDUCTOR FOR MULTIPLE CIRCUITS WITH ITS ASSOCIATED UNGROUNDED CONDUCTORS WHEN CONTAINED IN THE SAME ENCLOSURE. CEC 200.4(B)

6. THE BRANCH CIRCUIT SERVING EMERGENCY LIGHTING AND POWER CIRCUITS SHALL NOT BE PART OF A MULTIWIRE BRANCH CIRCUIT. CEC 700.19.

CONDUCTORS AND CABLES

COMMUNICATIONS PLAN NOTES
A. PROVIDE SEALTITE POWER & CONTROL CONNECTIONS TO ALL AC UNITS.

B. ALL EQUIPMENT SHOWN ABOVE ROOF IS NEMA 3R.

C. VERIFY EXACT EQUIPMENT LOCATIONS AND POINTS OF CONNECTION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.

D. CONDUIT SHOWN IS ROUTED IN CEILING SPACE BELOW ROOF DECK.E. NO ROOF MOUNT CONDUIT IS ALLOWED UNLESS OTHERWISE NOTED.F. FUSE DISCONNECT SWITCHES PER EQUIPMENT NAMEPLATE RATING.

G. ALL ROOF PENETRATIONS SHALL BE MADE WITH ROOF JACKS, SEAL ALL PENETRATIONS WITH MASTIC.

ROOF PLAN NOTES
A. REFER TO ARCHITECTURAL DEMOLITION SHEETS FOR ADDITIONAL INFORMATION.

B. EQUIPMENT SHOWN TO BE REMOVED IS SHOWN FOR REFERENCE ONLY. INFORMATION WAS OBTAINED FROM ORIGINAL BUILDING DRAWINGS AND LIMITED FIELD INVESTIGATION AND MAY NOT REPRESENT ALLELECTRICAL DEMOLITION. FIELD VERIFY CONDITIONS AND DISCONNECT/REMOVE ALL EQUIPMENT ASREQUIRED TO MEET THE INTENT OF THAT SHOWN ON THE LIGHTING AND POWER/SIGNAL DRAWINGS.

C. ALL ELECTRICAL EQUIPMENT SHOWN ON DRAWING (OR REQUIRED) TO BE DEMOLISHED SHALL BE DISCONNECTED, REMOVED AND DISPOSED OF BY ELECTRICAL CONTRACTOR. NO EQUIPMENT (RACEWAYS, BOXES, CABLING, ETC.) SHALL BE ABANDONED IN PLACE AND COVERED BY NEW CONSTRUCTION.

D. CLEAN, REPAIR (AS REQUIRED) AND RELAMP ALL EXISTING LIGHT FIXTURES THAT ARE TO REMAIN AND BE RE-USED TO ASSUME ALL FIXTURE ARE OPERATIONAL UPON COMPLETION OF PROJECT.

E. ANY LIGHT SWITCHES THAT ARE NO LONGER IN USE, WHETHER SHOWN ON THE DEMOLITION PLAN OR NOT, ARE TO HAVE THE DEVICE AND WIRING REMOVED, AND A BLANK COVER PLATE INSTALLED.

F. SCHEDULE ANY OUTAGES WITH OWNER PRIOR TO DE-ENERGIZATION OF ANY BRANCH CIRCUITS OR FEEDERS.

G. DISCONNECTION/REMOVAL OF EXISTING COMMUNICATIONS SYSTEMS COMPONENTS SHALL BE SCHEDULED WITH CITY OF SAN LUIS OBISPO.

H. SALVAGE ALL REMOVED COMPONENTS (SPEAKERS, GRILLES, TELEPHONE INSTRUMENTS, RADIO HANDSETS, ETC.) SHALL BE SALVAGED TO THE OWNER.

I. INFORMATION SHOWN FOR LOAD DESCRIPTIONS ON EXISTING PANELS WAS GAINED FROM ORIGINAL BUILDING ELECTRICAL PLANS AND SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL EXISTING PANELS AND PROVIDE UPDATED TYPEWRITTEN CIRCUIT DIRECTORY (IN PLASTIC SLEEVE) FOREACH EXISTING PANELBOARD.

J. ANY LOADS REMOVED DURING DEMOLITION SHALL HAVE CONDUCTORS REMOVED BACK TO NEXT REMAINING DEVICE OR TO EXISTING PANELS. ABANDONED BREAKERS SHALL BE LABELED "SPARE".

K. PROVIDE BLANK FILLER PLATES IN DEADFRONTS OF EXISTING PANELBOARDS UPON COMPLETION OF PROJECT WHERE BREAKERS HAVE BEEN REMOVED.

A. ALL 15 AND 20AMPERE RECEPTACLES FOR BOTH DAMP AND WET LOCATIONS REQUIRED TO BE LISTED WEATHER-RESISTANT (WR) TYPE PER CEC 406.9 (A) AND (B)
B. CEC 406.9(A) RECEPTACLES IN DAMP LOCATIONS: RECEPTACLES INSTALLED OUTDOORS IN A LOCATION

PROTECTED FROM THE WEATHER OR IN OTHER DAMP LOCATIONS SHALL BE AN ENCLOSURE FOR THERECEPTACLE THAT IS WEATHERPROOF WHEN THE RECEPTACLE IS COVERED (ATTACHMENT PLUG CAP NOT

INSERTED AND RECEPTACLE COVERS CLOSE)
C. CEC 406.9(B) RECEPTACLES OF 15 AND 20AMP, 125 AND 250 VOLTS INSTALLED IN A WET LOCATION SHALL

HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. AN OUTLET BOX HOOD INSTALLED FOR THIS PURPOSE SHALL BE LISTED AND SHALL BEIDENTIFIED AS 'EXTRA-DUTY" OTHER LISTED PRODUCTS, ENCLOSURES, OR ASSEMBLIES PROVIDING WEATHERPROOF PROTECTION THAT DO NOT UTILIZE AN OUTLET BOX HOOD NEED TO BE MARKED "EXTRA DUTY"EXCEPTION: 15 AND 20AMP, 125 THROUGH 250 VOLT RECEPTACLES INSTALLED IN A WET LOCATION AND

SUBJECT TO ROUTINE HIGH-PRESSURE SPRAY WASHING SHALL BE PERMITTED TO HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHEN THE ATTACHMENT PLUG IS REMOVED.

RECEPTACLES AT DAMP AND WET LOCATION

ELECTRICAL GENERAL NOTES
E-001
A. DATA AND TV RACEWAYS AND BOXES:
a. PROVIDE AND INSTALL 4" SQUARE RECESSED JUNCTION BOX WITH 1-GANG RING. RUN 3/4" EMT CONDUIT STUB TO ACCESSIBLE CEILING SPACE ABOVE FLOOR DATA MAX 3-CAT6A CABLES. b. PROVIDE AND INSTALL 5" SQUARE RECESSED JUNCTION BOX WITH 1-GANG RING. RUN 1-1/4" EMT CONDUIT STUB TO ACCESSIBLE CEILING SPACE ABOVE FLOOR DATA MAX 10-CAT6A CABLES.

BEFORE CONSTRUCTION, COORDINATE AND VERIFY ALL DATA AND TELEPHONE LOCATIONS WITH OWNER OR ARCHITECT.

B. ALL NEW HORIZONTAL CABLES, RISER RATED (CMR) CABLES SHALL BE CAT6A (BERK-TEK #LANMARK-10G2 - BLUE)
C. DEVICE LOCATIONS SHOWN ARE SCHEMATIC AND APPROXIMATE. EXACT LOCATIONS SHALL BE FIELD

VERIFIED DURING ROUGH-IN WITH ARCHITECTURAL ELEVATIONS, CASEWORK SHOP DRAWINGS, FURNITURE, ETC. AND SHALL BE COORDINATED WITH OTHER TRADES TO AVOID CONFLICT WITH OTHER EQUIPMENT.

D. ELECTRICAL AND COMMUNICATIONS OUTLETS SHOWN IN THE SAME LOCATION, SHALL BE MOUNTED ON OPPOSITE SIDES OF THE SAME STUD. COORDINATE BETWEEN ELECTRICAL AND COMMUNICATIONS PLANS.

E. CAT6A CABLES, TOTAL LENGTH FROM IDF TO ENDPOINT SHALL NOT BE MORE THAN 295'-0", EC SHALL BRING TO THE ATTENTION OF THE ENGINEER ANY LENGTHS IN EXCESS OF 295'-0".

F. ALL COMMUNICATION WORK SHALL COMPLY WITH CITY OF SAN LUIS OBISPO STANDARDS. OBTAIN COMPLETE LIST OF STANDARDS, AND ADHERE ACCORDINGLY.

G. TEST ALL NEW AND EXISTING RE-USE CABLES.

CONDUIT SYSTEMS NOTES

CONDUIT SYSTEMS USED ON THIS PROJECT SHALL BE AS FOLLOWS

1. PVC SCHEDULE 40 - underground/below slab with GRS elbows and risers tape wrapped).

2. ELECTRICAL METALLIC CONDUIT (EMT) - above grade/slab in building construction and where exposed above 8'-0" aff.

3. GALVANIZED RIGID STEEL (GRS) - where exposed below 8'-0" aff. and/or where subject to physical damage.

4. FLEXIBLE STEEL CONDUIT - above ceilings and/or concealed in building construction (seal tight flex required in exterior locations).

6. MC CABLE NOT ALLOWED.

REFER TO SECTION 260533 & 260500 OF SPECIFICATIONS FOR ADDITIONAL INFORMATION. CONDUITS SHALL BE MINIMUM 3/4" UNLESS OTHERWISE NOTED. CONDUIT SIZES, WHERE NOT NOTED ON THE DRAWINGS, SHALL BE SIZED FOR MAXIMUM 40% FILL PER CEC 310-6.

ADDITIONAL CONDUIT REQUIREMENTS.
- ROUTE CONDUIT(S) BELOW GRADE OR ABOVE CEILING SO THAT WALL OUTLETS, DEVICES, AND CONDUITS IN ALL EXPOSED BRICK WALL LOCATIONS SHALL BE RECESSED MOUNTED INSIDE BRICK. LOCATE DEVICES AT CELL WITH REINFORCEMENT CENTER AT BRICK AND/OR ONE CELL OVER AWAY FROM JAMB. REFER TO ARCHITECTURAL AND STRUCTURAL PLANS FOR CMU WALL LOCATIONS SECTIONS, AND DETAILS. - REFER TO ELECTRICAL DETAILS FOR METAL PIPE PENETRATION THRU FIRE RATED WALL. PENETRATION OF FIRE-RESISTIVE WALLS AND FLOOR CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SECTION 714. - REFER TO ELECTRICAL DETAIL FOR DEVICE INSTALLATION FOR FIRE RATED WALLS.- NO CONDUITS OR PIPING IN ANY SPACE SHALL BE EXPOSED AT THE CEILING AND WALL (COORDINATE WITH ALL DISCIPLINES PRIOR TO CONSTRUCTION). LOCATE ALL CONDUIT WITHIN WALLS R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L

Page 271 of 1531 ends

San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - K:\ENG\2024\24-8026\24-8026_E-002 - ELECTRICAL LEGEND & ABBREVIATIONS.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT

POWER LEGEND
NOTE: INTERPRET IN CONTEXT

MISCELLANEOUS

CONDUIT/WIRE

LIGHT FIXTURES

CONVENTIONS
LEGEND
3103
NUMBERED SHEET NOTES: REFERS TO NOTES ON SAME SHEET

AS REFERENCE
DETAIL REFERENCE:

Z = DETAIL DESIGNATION
X = SHEET NUMBER REFERENCE
Z
X

FEEDER SCHEDULE DESIGNATION
(EXAMPLE: 3103 = 310 AMPERE, 600V, 3 CURRENT CARRYING
CONDUCTORS, PREFIXES: 'M' INDICATES MEDIUM VOLTAGE, 'CO14' INDICATES CONDUIT ONLY, QUANTITY (1) AND SIZE (4"))
X

MECHANICAL SYSTEMS TAG
(REFER TO MECHANICAL SHEETS)
Y = UNIT TYPEX = UNIT NUMBER
YX

COMBINATION STARTERMAGNETIC CONTACTORDAMPER MOTORHUMIDISTATSURFACEMOUNT CABINETFLUSHMOUNT CABINETSURFACEMOUNT PANELFLUSHMOUNT PANELPUSHBUTTON H
M
DM

SPEAKER- WALLMOUNTSPEAKER- CLG FLUSHMOUNTHEADSET OUTLETAUXILIARY INPUTMICROPHONE INPUTCLOCK/SPEAKER WALLMOUNTSPEAKER- CLG FLUSHMOUNTVANDAL-RESISTANTVOLUME CONTROL VS

SEMI-FLUSH
S
A
HS
V
M
SS

CIRCUIT BREAKERFUSIBLE SWITCHGROUNDTHERMOSTAT

SURFACE

A LETTER ADJACENT INDICATES
(ARROW INDICATES DIRECTION)

FIXTURE TYPERECESSED WALL MOUNTEXIT LIGHT- CEILINGEXIT LIGHT- WALLWALL-PACK CLOCK
Ø PHASE
T
MOTOR

UPLIGHT- FLUSH IN GRADEPOLE LIGHT- DECORATIVEPENDANT LINEARUNDERCABINET LIGHTTANDEM-WIRED LAMPSBOLLARDSTRIP UONDIRECTIONAL FLOODEMERGENCY FIXTUREPOLE LIGHTTRACK LIGHTCEILING SURFACEMOUNTWALL SURFACEMOUNTRECESSED DOWNLIGHTRECESSED WALLWASHRECESSEDPENDANT MOUNT (E) POWER HOMERUN
INDICATES LINE CONTINUESWIRE LINE- CONTINUESCONDUIT STUB (W/MARKER)VERTICAL CONDUIT RUNFLEXIBLE CONNECTIONSURFACEMOUNT RACEWAYCORD W/PLUGLOW VOLTAGE LVCONDUIT SEALNEW POWER HOMERUN(3 HOTS & NEUT SHOWN)ISOLATED GROUNDEXISTING TO REMAINNEW E

UNDERGROUND

WALL MOUNTED CLOCK

S CLOCK/SPEAKER COMBINATION

SAFETY DISCONNECT
SOUND

END OF LINE RESISTORDUCT SMOKE DETECTORVISUAL- VISUAL DEVICEMANUAL PULL STATIONHORN- AUDIBLE DEVICEAUDIBLE/VISUALSMOKE DETECTORHEAT DETECTORBELL

T TAMPER SWITCH
P

FLOW SWITCH
AV
V
F
H

FIRE ALARM CONTROL PANEL

RPS REMOTE POWER SUPPLY

SV SPEAKER/VISUAL

FIRE ALARM

SFD SMOKE FIRE DAMPER

SDCOSDDSD
H
B

SMOKE DETECTOR WITH CO

WALL SURFACE MOUNT

LINEAR TYPE

LED COVE & UNDERCABINETLIGHT PER FIXTURE SCHEDULE

J JUNCTION BOX

SDV SMOKE DETECTOR WITH VISUAL
A AMPEREAB AMP BREAKERABAND ABANDONEDABV ABOVEAC ALTERNATING CURRENTAC-# AIR CONDITIONERADJ ADJACENTAF AMP FUSE, AMP FRAMEAFF ABOVE FINISH FLOORAFG BOVE FINISH GRADEAIC AMPERES INTERRUPTING CAPACITYAl ALUMINUMAS AMP SWITCH RATINGATS AUTOMATIC TIME SWITCHATS AUTOMATIC TRANSFER SWITCHAV AUDIBLE/AUDIO VISUALAWG AMERICAN WIRE GAGE

BFG BELOW FINISH GRADEBIL BASIC IMPULSE LEVELBLDG BUILDING

C CONDUIT
-C- CATV CONDUIT
CAB'T CABINETCATV CABLE TELEVISIONCB CIRCUIT BREAKER, CODE BLUECBC CA. BUILDING CODECEC CA. ELECTRICAL CODE CA. ENERGY COMMISSION
CF COMPACT FLUORESCENTCFC CALIFORNIA FIRE CODECLG CEILINGCL CENTER LINECKT CIRCUITCNT'R CONTRACTORC.O. CONDUIT ONLY (W/PULLROPE)COND CONDUIT, CONDUCTORCR CRITICAL BRANCHCSFM CALIFORNIA SFMCT CURRENT TRANSFORMERCu COPPERCU-# CONDENSING UNIT

D DEPTHDC DIRECT CURRENTDF DRINKING FOUNTAIN

DIA DIAMETERDISC DISCONNECTDIST DISTRIBUTIONDPST DOUBLE POLE SINGLE THROWDW DISHWASHEREM EMERGENCY (E) EXISTING
EA EACHEB ELECTRONIC BALLASTEC ELECTRICAL CONTRACTOREC-# EVAPORATIVE COOLEREF-# EXHAUST FANEL EVENING LIGHTELEC ELECTRICALEM EMERG BATTERY BACKUP

EMERGENCY BALLAST

EMERG EMERGENCYEOL END OF LINEEQUIP'T EQUIPMENTES ENERGY SAVING (EXN) (E) IN (N) LOCATION(EXR) (E) TO BE (R)

EXT EXTERIOR

F FLUORESCENT
(F) FUTURE
F-# FURNACEFA FIRE ALARMFACP FIRE ALARM CONTROL PANELFAT FIRE ALARM TERMINALFAU FORCED AIR UNITFBO FURNISHED BY OTHERS FC-# FAN COIL

FLA FULL LOAD AMPSFLR FLOORFLUOR FLUORESCENTFS FUSIBLE SWITCHFVNR FULL VOLTAGE NON-REVERSING

G GROUNDING CONDUCTORGC GENERAL CONTRACTORGD GARBAGE DISPOSALGFCI GROUND FAULT CIRCUIT

INTERRUPTER

GFI GROUND FAULT CIRCUIT

INTERRUPTER

GND GROUNDGRS GALVANIZED RIGID STEELGWS GANG WITH SWITCH

H HEIGHT, HIGHHACR HEATING, AC & REFRIGHID HIGH INTENSITY DISCHARGEHO HIGH OUTPUTHOA HAND-OFF-AUTO hp HORSEPOWER

HPF HIGH POWER FACTORHPS HIGH PRESSURE SODIUM

IC INTERCOMID IDENTIFICATIONIDF INTERMEDIATE DISTRIBUTION FRAMEIF INSIDE FROSTIG ISOLATED GROUND

J-BOX JUNCTION BOX
k QUANTITY 1000kVA KILOVOLTAMPSkW KILOWATT

LC LIGHTING CONTACTORLPS LOW PRESSURE SODIUMLRA LOCKED ROTOR AMPSLS LIFE SAFETY BRANCHLT LIGHTLTG LIGHTINGLV LOW VOLTAGEMC MECHANICAL CONTRACTORMCA MINIMUM CKT AMPSMCB MAIN CIRCUIT BREAKERMCTB MAIN CATV TERMINAL BOARDMCTC MAIN CATV TERMINAL CABINETMDF MAIN DISTRIBUTION FRAMEMECH MECHANICALMFR MANUFACTURERMFS MAIN FUSIBLE SWITCHMH METAL HALIDEMLO MAIN LUGS ONLYMOCP MAXIMUM OCPMPOE MINIMUM POINT OF ENTRYMSB MAIN SWITCHBOARDMT MOUNTMT HT MOUNTING HEIGHTMTS MANUAL TRANSFER SWITCH

MTTB MAIN TELEPHONE TERMINAL BOARDMTTC MAIN TELEPHONE TERMINAL CABINETMW MICROWAVEN NEUTRAL (GROUNDED CONDUCTOR) (N) NEW
N3R NEMA 3RNC NORMALLY CLOSEDNEC NATIONAL ELECTRICAL CODENEMA NAT'L ELEC MANUFACTURER'S ASSOCNIC NOT IN CONTRACTNL NIGHT LIGHTNO NORMALLY OPENNPF NORMAL POWER FACTORNTS NOT TO SCALE OC ON CENTEROCP OVERCURRENT PROTECTIONOD OUTSIDE DIAMETEROH OVERHEADOSA OFFICE of the STATE ARCHITECTOSHPD OFFICE of STATEWIDE HEALTH

PLANNING & DEVELOPMENT

OVLD OVERLOAD

P POLEPA PUBLIC ADDRESSPB PULLBOXPC PULL CHAINPC PHOTOCELLPC PLUMBING CONTRACTOR ph PHASE

PNL PANELPOC POINT OF CONNECTION
-PP- POWER PRIMARY-PS- POWER SECONDARY

PV PHOTOVOLTAIC
(R) RELOCATE(D)

RECEPT RECEPTACLEREF REFRIGERATORREQ'D REQUIREDRLA RATED LOAD AMPSRM ROOMRMC RIGID METAL CONDUITRMV REMOVERPLC REPLACERS RAPID START

SC SIGNAL CABINETSCC SHORT CKT CURRENTSFM STATE FIRE MARSHALSHT SHEETSL SLIMLINE, SWITCH LEG

SPEC SPECIFICATIONSPST SINGLE POLE SINGLE THROWSQ SQUARESTR'G STORAGESURF SURFACESVC SERVICESW SWITCH

T TRANSFORMER, TERMINAL
-T- TELEPHONE CONDUIT
(TBR) TO BE REMOVED

TC TIME CLOCKTEL TELEPHONETELCO TELEPHONE COMPANYTS TIME SWITCHTSO TIME SWITCH OVERRIDETSP TWISTED SHIELDED PAIRTTB TELEPHONE TERMINAL BOARDTTC TELEPHONE TERMINAL CABINETTX TRANSFORMERTYP TYPICAL

TYP SIM TYPICAL SIMILAR
UC UNDERCABINET, UNDERCOUNTERUG UNDERGROUNDUGPS UNDERGROUND PULL SECTIONUL UNDERWRITERS LABORATORIESUON UNLESS OTHERWISE NOTEDUSA UG SVC ALERT 800-642-2444

V VOLTVA VOLT AMPERESVAC VOLT ALTERNATING CURRENTVHO VERY HIGH OUTPUTVOLT VOLTAGEVR VANDAL-RESISTANT

W WIDTH, WATT, WIRE
WH-# WATER HEATERWP WEATHERPROOF (NEMA 3R)

XFMR TRANSFORMER
+48 INDICATES MOUNTING HEIGHT AFF

FIXTURE TYPE

LIGHTING PLAN
B-1,a

CIRCUIT NUMBER
A

POWER PLAN
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM DEVICES TO PANEL(S) PER DESIGNATIONS/CIRCUIT NUMBERS.- EACH BRANCH CIRCUIT SHALL HAVE A SEPARATE NEUTRAL AS INDICATED ON PANEL SCHEDULES.- HOME RUN CONDUITS SHALL BE 3/4"C, MAX OF (3) BRANCH CIRCUITS PER CONDUIT.- INCREASE HOME RUN CONDUIT SIZE TO 1"C FOR (4) BRANCH CIRCUITS OR MORE.- (**) DENOTES SPECIAL DEVICE/NAMEPLATE REQUIREMENTS. - PROVIDE ALL BRANCH CIRCUIT WIRING FROM FIXTURES TO PANEL(S) AS DESCRIBED BY CIRCUIT NUMBERS SHOWN.
- PROVIDE ALL WIRING BETWEEN FIXTURES AND CONTROL DEVICES AS DESCRIBED IN REFERENCE NOTES AND/OR SHOWN BY SWITCHLEG DESIGNATIONS. - EXIT AND EMERGENCY LIGHT FIXTURES SHALL BE CONNECTED TO AN UNSWITCHED BRANCH CIRCUIT CONDUCTOR.
- HOME RUN CONDUITS SHALL BE 3/4"C., MAX OF (3) BRANCH CIRCUITS PER CONDUIT.
- PROVIDE ALL BRANCH CIRCUIT WIRING FROM MECH. EQUIPMENT TO PANELS.

SWITCHLEG DESIGNATION
(WHERE SHOWN)
DEVICE TYPE:

SEE LEGEND
MOUNTING HEIGHT: (WHERE NON-STANDARD)
W - 48" ABOVE FINISHED FLOOR

M - ABOVE COUNTER TOP (COORDINATION REQUIRED)

TV - MOUNT AT TV HEIGHT (COORDINATION REQUIRED)

CLG - CEILING MOUNT
SPECIAL CONFIGURATION:

WP - **WEATHER PROOF, PROVIDE WHILE IN USE COVER
GFI - **GROUND FAULT CIRCUIT INTERRUPTED

IG - ISOLATION GROUND

GWS - GANG WITH SWITCH
CONTROLLED RECEPTACLE:
(IF APPLICABLE)

SEE LIGHTING CONTROL DETAIL FOR

ADDITIONAL INFORMATION
CIRCUIT NUMBER:

BRACKETS ('[]') DENOTE
EXISTING CIRCUIT.

PANEL DESIGNATION
NOTE: THE INTENT OF THE DRAWINGS IS TO SHOW FIXTURE / DEVICE LOCATIONS AND PANEL DESIGNATIONS. ALL BRANCH CIRCUIT WIRING, MEETING THE CRITERIA NOTED ABOVE, WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LIGHTING AND POWER PLANS SHOW AN ABOVE CEILING JUNCTION BOX / HOME RUN WITH CIRCUIT NUMBERS BY FIXTURES / DEVICES. PROVIDE ALL BRANCH CIRCUITING AS REQUIRED FOR A COMPLETE INSTALLATION. DOCUMENT ALL BRANCH CIRCUITING ON AS-BUILT DRAWINGS ACCURATELY REFLECTING THE INSTALLATION.

CIRCUITING LEGEND

ABBREVIATIONS
20A DUPLEX RECEPTACLE
20A (GFCI) GROUND FAULT CURRENT INTERRUPTER DEVICE
20A MOUNT ABOVE COUNTER PER ADA. MOUNT AT +48" MEASURED TO TOP OF BOX.

WHILE-IN USE NEMA 3R COVER (TAYMAC #MX4280S OR ENGINEER APROVED

EQUAL UNLESS OTHERWISE NOTED)FLOOR MOUNTED OUTLET

GROUND BAR
20A CEILING MOUNTED OUTLET

GANG WITH SWITCH

DISCONNECT FUSE OR NON FUSED
20 DOUBLE DUPLEX RECEPTACLE
TELEVISION OUTLET. VERIFY MOUNTING HEIGHT PRIOR TO ROUGH-IN.

COMBINATION POWER/DATA FLOOR BOX.
20A SINGLE RECEPTACLE20A DUPLEX- HALF SWITCHED20A SWITCHED RECEPTACLE

J DROP CORD RECEPTACLE
208V 1Ø RECEPTACLE
20AMP DUPLEX OUTLET WITH TYPE A AND TYPE C USB CHARGER

SDS SMOKE DETECTOR WITH SOUND
NOTE: "C" NEXT TO NOTIFICATION

DEVICE ON PLANS DENOTES MOUNT AT

CEILING
J
SF
SF

WALL MOUNTED SYSTEM FURNITURE COMMUNICATION
CONNECTION.

ELECTRICAL LEGEND AND ABBREVIATIONS
E-002

COMMUNICATION LEGEND

TELE POWER POLE
NEW FLUSH MOUNTED DATA OUTLET SHOWN. X DENOTES
TOTAL CAT6A CABLES AND PORT FACEPLATE
TV MOUNT DATA OUTLET AT TV HEIGHT. PROVIDE 1-CAT6A CABLE.

WALL MOUNTED SYSTEM FURNITURE POWER CONNECTION.
#
CAM
AP

SECURITY CAMERA

WIRELESS ACCESS POINT
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 272 of 1531 ends

San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - K:\ENG\2024\24-8026\24-8026_E-003 - ELECTRICAL SINGLE LINE DIAGRAM AND SCHEDULES.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 (E) "MSB" SINGLE LINE DIAGRAM
(E) "MSB"
M

PRIMARY SECONDARY
800A BUS, 120/208V, 3 PHASE 4 WIRE
(E)
PANEL
A
PANEL
B
PANEL
C
(E)PRIM (E)SEC
(E)TRANSFORMER T-578
(E)
150A
3P

EXISTING EXISTING EXISTING
PANEL
D
EXISTING AC-1 AC-2 ELEVATOR

ELECTRICAL SINGLE LINE
E-003
A. ILLUSTRATIONS AND/OR DIMENSIONS ARE APPROXIMATIONS ONLY INTENDED TO REPRESENT BASIC FIXTURE TYPE; DO NOT USE AS EXACT INFORMATION SOURCE. REFER TO MANUFACTURER CUT
SHEETS.

B. EXACT LOCATIONS: BEFORE CONSTRUCTION, VERIFY WITH

ARCHITECT EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL
LIGHT FIXTURES. SEE ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS AS APPLICABLE.

C. FIXTURE BRANCH CIRCUIT THROUGH-WIRING: VERIFY AND COMPLY

WITH FIXTURE MANUFACTURER RESTRICTIONS AS DETERMINED BY UL. & NEC.

D. VERIFY CEILING TYPES/FINISHES FOR ALL RECESSED FIXTURES PRIOR TO FORWARDING SUBMITTALS.

E. ALL RECESSED LUMINAIRES IN CEILINGS SHALL BE LISTED TYPE IC. (E)
150A
3P
(E)
150A
3P
(E)
100A
3P
(E)
40A
3PSPARE
(E)
200A
3P
(E)
200A
3P
(E)
150A
3P
(E) 800A
3P, MAIN
(E)
80A
2P
LEVEL 2

EV CHARGER

REFERENCE NOTES

1. EXISTING PANELBOARDS. SEE POWER / SIGNAL FLOOR PLANS FOR LOCATION. INFORMATION LOAD DESCRIPTIONS ON EXISTING PANELS

WAS GAINED FROM ORIGINAL BUILDING ELECTRICAL PLANS AND
SHALL BE FIELD VERIFIED. CONFIRM LOAD ON EACH CIRCUIT OF ALL

EXISTING PANELS PROVIDE UPDATED TYPEWRITTEN CIRCUIT
DIRECTORY (IN PLASTIC SLEEVE) FOR EACH EXISTING PANELBOARD.

2. DESIGN IN SITE SCOPE SEPARATE PERMIT.

A. ALL CONDUCTORS SHALL BE COPPER WITH TYPE [THHN/THWN] INSULATION UNLESS OTHERWISE NOTED.

B. ALL SWITCHES, CIRCUIT BREAKERS AND OTHER EQUIPMENT, AS

SPECIFIED, SHALL HAVE TERMINATION PROVISIONS LISTED AND IDENTIFIED FOR USE WITH 75 DEG. CONDUCTORS, AND ALL FEEDER CONDUCTORS, AND CONDUITS, ARE SIZE BASED ON USE OF 75 DEG.C COPPER WIRES TYPE THWN/THHN.

C. ALL EQUIPMENT SHALL HAVE AN APPROVED TESTING LABORATORY LABEL ATTACHED [UL, CSA, ETC.] (CEC 110-2).

SINGLE LINE DIAGRAM NOTESFIXTURE SCHEDULE NOTESLIGHTING 2 "MSB" LOAD CALCULATIONS

INTERIOR LIGHTING FIXTURE SCHEDULE
MAX.

VA. TYPE ILLUSTRATION MANUFACTURER CATALOG NO. VOLTAGE LAMPING MOUNTING DESCRIPTION D1
LITHONIA LDN4 40/10 LO4 AR
LD TRW MVOLT EZ1
MVOLT 11 LED
4000K
RECESSED 4" RECESSED LED DOWNLIGHT.

W1
LITHONIA FMVCCLS 24IN

MVOLT BN
MVOLT 18.12 LED
4000K

WALL ABOVE
MIRROR
2' CONTEMPORARY CYLINDER
VANITY
W2
LITHONIA MVOLT 34.86 LED
4000K
1 1 1 1

EXIT SIGN AND EMERGENCY LIGHTING FIXTURE SCHEDULE
MAX.

VA. TYPE ILLUSTRATION MANUFACTURER CATALOG NO. VOLTAGE LAMPING MOUNTING DESCRIPTION X1
ISOLITE EDC-EM-R-1-XX-XX
-MTEBP
MVOLT 5 LED UNIVERSAL UNIVERSAL MOUNT LED EXIT

SIGN WITH UNIVERSAL FIELDSELECTABLE CHEVRONS AND
EMERGENCY BATTERY BACKUP.

X2

ISOLITE CMB-EM-R-U-XX
-MTEBP-L1
MVOLT 8 LED UNIVERSAL
XM
ISOLITE BUG-3W-WH-MB MVOLT 6 LED SURFACE
XM
E
ISOLITE OWL-EM-XX-MB MVOLT 17 LED WALL

UNIVERSAL MOUNT LED EXIT

SIGN AND EMERGENCY LIGHTCOMBO WITH UNIVERSAL FIELDSELECTABLE CHEVRONS AND EMERGENCY BATTERY BACKUP.

LED EMERGENCY LIGHT.

EXTERIOR LED EMERGENCY
LIGHT.

FMVCCLS 48IN

MVOLT BN

WALL ABOVE
MIRROR
4' CONTEMPORARY CYLINDER
VANITY
(SITE PROJECT)
2 1 R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 273 of 1531 ends

UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
J
"B"
J J
J
J
J
J J
J
J
JJ

J J J J J J
V
J
J J
J
J
J
J
J
(TBR)
(TBR) (TBR)
(TBR)
7 E-201
10 E-201
30A, 120/250V, 1Ø 1
ED-101

EXISTING TELEPHONE BACKBOARD

AND MAIN POINT OF ENTRY
"A"
"MSB"
"FACP"
S
S
(E)SAFE
B-16
B-16
B-16
B-16
B-16
B-16
B-22
B-22
B-3,26 B-3
B-3
B-26 B-26
B-3
B-3 B-3
B-3,26
B-3
B-3,26
B-2
B-2
B-2 B-19
B-2
B-19
B-2
B-2
B-6,15
B-9,10,12 J
B-4,6,17
B-10,11
A-4
B-13,14 B-13,14 B-8 A-4
A-4
B-22
A-20 A-20
A-20
A-20
A-20 B-28
B-28
A-20
A-18
B-2
B-2
A-9
A-9
A-24
A-9
A-9
A-4
A-16
A-15A-13
A-13
A-13
A-17
A-13
A-13
A-16
A-9
A-9
A-16 A-16
A-36
A-36 A-36
A-15
A-15
A-16
J J
SHARED
OFFICE
BUREAU

SERGEANT
107

DETECTIVE

EQUIPMENT
106
DRONE/EQUIP.

STORAGE
105
STAIR
MEN
118
WOMEN
119
HALL
115
JAN.

ELECTRICAL
120

CIRCULATION
130

BRIEFING
ROOM
'122

MEETING
125
OFFICE
124
ELEV.

STAIR
LOBBY
100

STORAGE
111
OPEN
OFFICE

BREAK ROOM
OFFICE
HALL
2 2 2
(TBR)
2 (TBR)
23 4
4 +84"
6 2 4
2 2 2 4 2
2 2
4 66
4 2
2 (TBR)
(TBR)
(TBR)
1 2
(TBR)
2 3 3
4 17
56 7
8 9
(EXR)
10 J
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - K:\ENG\2024\24-8026\24-8026_ED-101 - 1ST FLR PWR & SIG DEMO PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
NORTH
SCALE:

POWER / SIGNAL DEMOLITION FIRST FLOOR PLAN
3/16"=1'-0"

POWER / SIGNAL DEMOLITION FIRST FLOOR PLAN
ED-101
NOTE: ALL DEVICES SHOWN ON THIS PAGE ARE EXISTING UNLESS

OTHERWISE NOTED)
1 EXISTING DATA RACK ATELECTRICAL ROOM

REFERENCE NOTES

1. REMOVE AND DISCONNECT OUTLET.

2. REMOVE AND DISCONNECT DATA WIRING FROM EXISTING DATA RACK.

3. REMOVE AND DISCONECT EXISTING OUTLET AT DEMO WALL. RE-USE EXISTING BRANCH CIRCUITS AT NEW OUTLETS.

4. EXISTING FLOOR BOX SHOWN ON AS-BUILT. FIELD VERIFY EXACT LOCATION UNDER CARPET. VERIFY EXISTING BRANCH CIRCUIT ANDLABEL.

5. DISCONNECT/REMOVE EXISTING JUNCTION BOX AT FLOOR. CAP EXISTING CONDUIT.

6. EXISTING (17)CAT6 CABLES AT FLOOR. RE-USE (4)CAT6 FOR OUTLETS AT NEW WALL. TONE EXISTING CABLES NOT USED AND DISCONNECT CABLES AT EXISTING DATA RACK. PULL EXISTING CABLES FROMCEILING SPACE. COORDINATE WITH CITY IT FOR ADDITIONAL REQUIREMENTS PRIOR TO DEMO. CAP EXISTING CONDUITS.

7. RE-USE EXISTING BRANCH CIRCUIT TO POWER NEW OUTLETS AT NEW WALL. INTERCEPT EXISTING BRANCH CIRCUIT ABOVE T-BAR CEILING AND EXTEND NEW BRANCH CIRCUIT TO NEW OUTLETS.

8. EXISTING 6-DATA TO BE RELOCATED TO SOUTH WALL.9. REMOVE EXISTING DOUBLE DUPLEX. RE-USE EXISTING BRANCH CIRCUITS FOR NEW SYSTEM FURNITURE. INTERCEPT EXISTING BRANCHCIRCUITS ABOVE-TBAR CEILING AND EXTEND NEW BRANCH CIRCUIT.

10. EXISTING FLOOR MOUNTED DATA RACK. PROVIDE AND INSTALL (2)48 CAT6A PORT AT EXISTING DATA RACK. HOMERUN ALL NEW FIRST FLOOR CAT6A CABLES TO THIS RACK.

X R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 274 of 1531 ends

UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
W
"D"
J
J
J
J
J
HH
V
J
W
MM
J
J
M
J
J
J
HDMI
J
6 VIDEO S
J
J
J
J
H
8 E-201
9 E-201
V V
J
V
V
V
V
P
M
(E)SYSTEM

FURNITURE (POC)
J
(E)SYSTEM

FURNITURE (POC)
(E)ELEVATOR UNIT

AND DISCONNECT
V
V
V
"C"
3 2
1 1
(EXR)
(EXR) (EXR) (EXR)

MEETING
ROOM
202

PUBLIC AFFAIRS

MANAGER
205
BOS.

MANAGER
208
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
WOMENS
222
HALL
STAIRS
144
SERVER
216
EQUIP.
220
BREAK
ROOM
215
CHIEF
214C
ADMIN
214A
DEPT.

CHIEF
213
DEPT.

CHIEF
211
ELEV.

MECH
112
COPY
ROOM
210
ELEV.

CONF.
202

TRAIN/HIRING

MANAGER
208
CRIME

ANALYST
209
2 2 2
2 2
2 4 4 2
2 2
2 2
2 2
2 2
3 6
2 2
4 4
2 2
4 4
2 J J J
4 4 4
3 3
J
4 1
ED-102
55 San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - K:\ENG\2024\24-8026\24-8026_ED-102 - 2ND FLR PWR & SIG DEMO PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT

REFERENCE NOTES

1. REMOVE EXISTING SURFACE MOUNT RACEWAY AT THIS AREA.

2. DISCONNECT EXISTING MOTORIZED SCREEN AND RECONNECT TO NEW LOCATION.

3. PROTECT EXISTING FLOOR BOXES IN THIS ROOM.

4. EXISTING WALL MOUNTED DATA RACK. PROVIDE AND INSTALL (1)24 CAT6A DATA PORT. HOMERUN ALL NEW SECOND FLOOR CAT6A TO THISCABINET.

5. EXISTING SYSTEM FURNITURE CONNECTIONS. RE-USE (2) CAT6 CABLES AND TERMINATE TO NEW WALL TV OUTLETS. RE-USE THE REST OF THE CAT6 CABLES AND TERMINATE TO FACEPLATE AND STANDARD HEIGHT.

FIELD VERIFY EXACT LOCATION OF SYSTEM FURNITURE. FURNITURE WERE IN THE WAY TO VERIFY IF THE SOUTH PILLAR HAD CONNECTIONS.

RE-USE EXISTING BRANCH BRANCH CIRCUIT TO POWER NEW OUTLETS AT NEW WALL.

NORTH
SCALE:

POWER / SIGNAL DEMOLITION SECOND FLOOR PLAN
3/16"=1'-0"

POWER / SIGNAL DEMOLITION SECOND FLOOR PLAN
ED-102
NOTE: ALL DEVICES SHOWN ON THIS PAGE ARE EXISTING UNLESS

OTHERWISE NOTED)
EXISTING DATA RACK ATELECTRICAL ROOM 1
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 275 of 1531 ends

1 1
A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
TV TV
TV
TV
J
B-6,15

TV TV TV
J
A-3
1 J
A-38,40
TV
J
4 CLG CLG
3 2
11 5
(E) "A"
(E) "MSB"
(E) "FACP"
8 SF
SF
J
12 1 1
1 1
12 1
J
B-3,26 B-3
B-3 B-3
B-3,26
B-3
B-3 B-3,26 (N) 6 (N)
3 3(N) (N)
(E) (E)
(E) (E)
(E)
B-3,26
B-26
(N)
33 33
33 33
33 (E)B-2B-2
J
B-10,11
B-10
B-10
3 B-10
J
A-4
B-13 3
(E) (E) B-8 (E)
B-22
(N) A-18
6 (E) (E) (E)
(E)
A-20
A-20
A-20 B-28
B-28
A-20
(E)
(E)
(E)
(E)
(E)
(E)
A-9
A-9
G
G
10 6
CKT, B-6
CKT, B-6
CKT, B-6
CKT, B-6 CKT, B-15
CKT, B-6
CKT, B-15
CKT, B-15 CKT, B-15
CKT, B-15
(N) (N)
(N)
(N)
(N)
(N)
(N) (N)
(E)
(N)
(N)
(N)
(N)
6 (N)
(N)
(N) (N)
(N)
9 7
7 8 (E) "B"
SHARED
OFFICE
126
BUREAU

SERGEANT
107

DETECTIVE

EQUIPMENT
106
DRONE/EQUIP.

STORAGE
105
STAIR
MEN
118
WOMEN
119
HALL
115
JAN.

ELECTRICAL
120

CIRCULATION
130

BRIEFING
ROOM
122

MEETING
125
OFFICE
124
ELEV.

STAIR
LOBBY
100

STORAGE
111
OPEN
OFFICE

BREAK ROOM
121
OFFICE
123

STORAGE
133
HALL
114
AP
(N)
AP
(N)
(N) G
A-17
13 38
38 38
38 14
(N)
15 15
(E)
2 (E)
2 (E)
3 (E)
4 (E)
4 (E)
4 (E)
2 (E)
4 2 2 2
(E)
2 (E)
4 66
(N)
40 2
19 18
18 17
CAM
16 (N)
21 J
5 (EXN)
20 18
(E) (E) (E)
21 5
1 ED-101
22 (E)
(E)
A-15
21 (N) 6
(E)
(E) (E)
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - K:\ENG\2024\24-8026\24-8026_E-101 - 1ST FLR PWR & SIG FLR PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT

REFERENCE NOTES

1. PROVIDE 120V DEDICATED CIRCUIT FOR DOOR ACCESS CONTROL PANEL. COORDINATE EXACT LOCATION WITH CITY VENDOR PRIOR TO ROUGH-IN. CONNECT TO EXISTING SPARE BREAKER AT PANEL "A".

2. CONNECT TO MOTORIZED SCREEN. COORDINATE WITH
MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN.

3. MOTORIZED SCREEN CONTROLLER. PROVIDE WIRING TO MOTORIZED SCREEN PER MANUFACTURER INSTALLATION GUIDE.

4. PROVIDE 120V CONNECTION TO PROJECTOR. VERIFY EXACT LOCATION WITH OWNER PROVIDED EQUIPMENT.

5. EXTEND EXISTING BRANCH CIRCUIT.6. SYSTEM FURNITURE POINT OF CONNECTION. RE-USE EXISTING BRANCH CIRCUITS LOCATED ABOVE T-BAR CEILING. INTERCEPT AND EXTEND BRANCH CIRCUITS TO SYSTEM FURNITURE. COORDINATE WITH SYSTEM FURNITURE MANUFACTURE.

7. REPLACE EXISTING OUTLET WITH NEW GFCI OUTLET AND COVERPLATE.

8. EXISTING PANEL.9. EXTEND EXISTING RECEPTACLE BRANCH CIRCUIT IN THIS ROOM TO NEW OUTLET(S).

10. EXISTING DATA OUTLET BOX IN THIS SYSTEM FURNITURE. FIELD VERIFY EXACT LOCATION. PROVIDE (3)NEW CAT6A CABLES. TYPICAL AT SYSTEM FURNITURES.

11. THIS DATA OUTLET FOR SYSTEM FURNITURE WILL REQUIRE A BOX AND 1-1/5" CONDUIT TO ACCOMMODATE (12)CAT6A CABLES.

12. PROVIDE 120V DEDICATED CIRCUIT FOR MOTORIZED BLACK OUT SHADES. COORDINATE WITH MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN.

13. CONNECTION TO NEW DRINKING FOUNTAIN. EXTEND EXISTING CIRCUIT FROM BREAK ROOM OUTLET.

14. PROVIDE (2)20A/1P BREAKER TO MATCH EXISTING TO SPACES 38 AND

40. PROVIDE UPDATED TYPED PANEL SCHEDULE.

15. WIRELESS ACCESS POINT FURNISHED AND INSTALLED BY OWNER. EC TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE.

PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE.

16. SECURITY CAMERA FURNISHED AND INSTALLED BY OWNER. EC TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE.PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE.

17. PROVIDE 15FT TELE-POWER ONE COMPARTMENT POLE FOR (18)CAT6A TO TERMINATE AT SYSTEM FURNITURE DATA OUTLET BOXES.
(WIREMOLD 30TC-2WH) EC TO PROVIDE ALL ACCESSORIES FOR A COMPLETE WORKING SYSTEM.

18. INTERCEPT EXISTING BRANCH CIRCUIT AT ACCESSIBLE CEILING SPCE NEAR EXISTING PILLAR AND EXTEND TO NEW OUTLET(S).

19. RE-USE EXISTING CAT6 CABLES AND TERMINATE AT TV AND STANDARD HEIGHT.

20. NEW LOCATION OF EXISTING DATA OUTLETS.21. REPLACE EXISTING DUPLEX OUTLET WITH DOUBLE DUPLEX. CHANGE BOX, RING, DEVICE AND PLATE.

22. INSTALL 2-3" (EMT) CONDUIT SLEEVES ABOVE T-BAR CEILING TO FIRST FLOOR DATA RACK FOR NEW LOW VOLTAGE WIRING.

NORTH
SCALE:

POWER / SIGNAL FIRST FLOOR PLAN
3/16"=1'-0"

POWER / SIGNAL FIRST FLOOR PLAN
E-101
NOTE: CUT AND PATCH EXISTING WALLS WHERE
NEW OUTLETS ARE SHOWN.

R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L

Page 276 of 1531 ends

UP
UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
2 (E)(E)
TV
TV
3 8
(E)
TV TV
3 TV TV
3 J
J
3 CLG CLG
(E) (E)
(E) (E) (E)
(E)(E)
(E)(E)
(E)
(N)
C-34,36
TV
(E)
(EXN)
3 C-38
11 1 (E) "C"
1 (E) "D"
45 6
10 (E)
(E)
77 7
(E)
DS
1 (IDU)
208V, 1ɸ

0.5 MCA
15 MOCP
2 12
M
13 C-40/42
14 15
36 34
3636
36 34
16 (E)
G
(E)
G
17 17
2 (N)
(N)
(N) (N)
3 3
(N)
(N)
(N)
(N) (E)
3 (E) (E)
(E) (E) (E)
(E)
6 1
1 6
1 M
(EXN)
(EXN)
(EXN)
(N)
3 1
M
(N)
G,M
(N) G,M

G,M G,M
18 (EXN)

MEETING
ROOM
202

PUBLIC AFFAIRS

MANAGER
205
BOS.

MANAGER
208
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
WOMENS
222
HALL
STAIRS
144
SERVER
216
EQUIP.
220
BREAK
ROOM
215
CHIEF
214C
ADMIN
214A
DEPT.

CHIEF
213
DEPT.

CHIEF
211
ELEV.

MECH
112
COPY
ROOM
210
ELEV.

CONF.
202

TRAIN/HIRING

MANAGER
208
CRIME

ANALYST
209
JAN.
(E)(E)
TV
TV
3 1
(E)
(E) (E) (E) (E)
AP
(N)
AP
(N)
19 19
J J J
4 4
4 (E) (E) (E)
20 (E)
2 (E)
2 (E)
2 (E)
2 (E)
2 (E)
2 (N)
36 (E)
6 (E)
2 (E)
4 (E)
4 (E)
2 (E)
2 M
2 (E)
2 (E)
2 (E)
2 (E)
2 (E)
2 (E)
2 (E)
3 (E)
6 (E)
2 (E)
2 (E)
4 (E)
4 (E)
2 W
2 (E)
4 (E)
4 3
22 22
22 6
6 23
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:41pm - Chris - K:\ENG\2024\24-8026\24-8026_E-102 - 2ND FLR PWR & SIG FLR PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT

REFERENCE NOTES

1. EXISTING BRANCH CIRCUIT PANELBOARD.

2. REPLACE EXISTING DUPLEX OUTLET WITH NEW DOUBLE DUPLEX OUTLET.

3. EXTEND EXISTING RECEPTACLE BRANCH CIRCUIT IN THIS ROOM TO NEW OUTLET(S).

4. CONNECT TO MOTORIZED SCREEN. COORDINATE WITH
MANUFACTURER INSTALLATION GUIDE PRIOR TO ROUGH-IN.

5. MOTORIZED SCREEN CONTROLLER. PROVIDE WIRING TO MOTORIZED SCREEN PER MANUFACTURER INSTALLATION GUIDE.

6. PROVIDE 120V CONNECTION TO PROJECTOR. VERIFY EXACT LOCATION WITH OWNER PROVIDED EQUIPMENT.

7. RE-USE EXISTING BRANCH CIRCUIT FROM EXISTING SYSTEM
FURNITURE CONNECTION.

8. RELOCATE EXISTING RECEPTACLE AND DATA OUTLET TO BE ABOVE NEW COUNTER SPACE. INTERCEPT EXISTING BRANCH CIRCUIT TO NEW LOCATION. PROVIDE NEW DUPLEX DEVICE AND PLATE.

9. NOT USED.

10. LOCATE FOR NEW COPIER.11. PROVIDE NEW DEDICATED CIRCUIT AND OUTLET FOR EXISTING REFRIGERATOR.

12. EXISTING WALL MOUNTED DATA RACK.13. PROVIDE LINE VOLTAGE CONNECTION TO MECHANICAL UNIT.

ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION WITHMECHANICAL PLANS AND PROVIDE 2-POLE, NEMA 1 DISCONNECT PERMANUFACTURER'S REQUIREMENTS.

14. NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C".

PROVIDE NEW 20A/2P CIRCUIT BREAKER IN PANEL AS DESIGNATED TOMATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1) #12 CU GROUND.

15. NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C".

PROVIDE NEW 20A/1P CIRCUIT BREAKER IN PANEL AS DESIGNATED TOMATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1) #12 CU GROUND.

16. NEW 20A BRANCH CIRCUITS TO EXISTING PANEL "C". PROVIDE (2) NEW 20A/1P CIRCUIT BREAKERS IN PANEL AS DESIGNATED TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (4) #12 THWN AND (1) #12 CU GROUND.

17. REPLACE EXISTING OUTLET WITH NEW GFCI OUTLET AND COVER.18. REPLACE EXISTING SWITCH AND OUTLET WITH NEW DEVICE AND PLATES. PROVIDE NEW OUTLET AS SHOWN AND EXTEND EXISTING BRANCH CIRCUIT. RE-USE EXISTING BRANCH CIRCUIT FROM EXISTING OUTLET IN THIS LOCATION.

19. WIRELESS ACCESS POINT FURNISHED AND INSTALLED BY OWNER. EC TO PROVIDE 2-PORT BISCUIT MOUNTED IN ACCESSIBLE CEILING SPACE.

PROVIDE 1-CAT6A CABLES AND TERMINATE (FEMALE) AND TEST CABLE.

20. MOVE EXISTING OUTLET TO NEW WALL. INTERCEPT EXISTING BRANCH CIRCUIT AND EXTEND TO NEW LOCATION. PROVIDE NEW DEVICE ANDCOVER PLATE.

21. RE-USE EXISTING CAT6 CABLES AND TERMINATE AT NEW TV OUTLET22. TERMINATE ALL EXISTING CAT6 AT EXISTING SYSTEM FURNITURE LOCATION AT WALL OUTLET AT STANDARD HEIGHT. ASSUMED
(26)EXISTING CAT6 CABLES FROM EXISTING SYSTEM FURNITURE.

23. PROVIDE 2"C (EMT) SLEEVE ABOVE T-BARD CEILING FROM 2ND FLOOR DATA CABINET FOR NEW CAT6A CABLES.

NORTH
SCALE:

POWER / SIGNAL SECOND FLOOR PLAN
3/16"=1'-0"

POWER / SIGNAL SECOND FLOOR PLAN
E-102
NOTE: CUT AND PATCH EXISTING WALLS WHERE
NEW OUTLETS ARE SHOWN.

R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L

Page 277 of 1531 ends

UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
4 -
OS
OS
(EXR) (EXR) (EXR)
(TBR)
(TBR) (TBR)
3 -
(TBR)
(TBR)
SHARED
OFFICE
BUREAU

SERGEANT
107

DETECTIVE

EQUIPMENT
106
DRONE/EQUIP.

STORAGE
105
STAIR
MEN
118
WOMEN
119
HALL
115
JAN.

ELECTRICAL
120

CIRCULATION
130

BRIEFING
ROOM
'122

MEETING
125
OFFICE
124
ELEV.

STAIR
LOBBY
100

STORAGE
111
OPEN
OFFICE

BREAK ROOM
OFFICE
HALL
2 -
3 (EXR)
2 OS
OS
(EXR) 3
(EXR)
(NL)
(NL)
X2
(NL)(NL)
6 (N)XM
(N)
(NL)
(NL)
XM
7 4
4 OS
4 OS
(N) XME
9 (NL)
10 10 10
10 (E) (E) (E) (E) (E)(E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E)(E)
(E) (E)
(E)
(E)(E)(E) (E)
(E)(E)
(E) (E)(E) (E)
(E)(E)
(E)
(E)(E)
(E)
(E)(E)
(E)
(E)
(E)(E)(E) (E)
(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)
(E)(E)(E)
(E)(E)
(E)(E) (E)
(E)
(E) (E) (E)
(E)
(E)
(E) (E)
(E)
(E)
(E) (E)
(E)
(E)
(E)
(E) (E)
(E)
(E)
(E)
(E)
(E)
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG 10
10 10 (N) CLG
(N) XM
7 5
-
(EXR)
12 RPP (EXN) (EXN) (EXN)
WS
WS,D
(N)
WS
OS
WS
OS
1 SHARED
OFFICE
SHARED
OFFICE
126
BU
SER
OS
D1
W1
D1
11 W1
MEN
118
WOMEN
119
OS
OS
OS
XM
OS XME
X2
(EXN) (EXN)
9 (N)XM
10 6
4 4
4 OS
4 (N)XM
10 (N) XM
10 (E) (E)
(E)(E)(E)
(E)
(E) (E)
J
11 (N)X2
(EXN)
(NL)
5 (EXN)
9 (N)
X1
X2
(E)(E)
(E)
(EXN)(NL)
(N)
XME
(N) XM
CLG
J
OS
(E)
(EXN)
12 San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:42pm - Chris - K:\ENG\2024\24-8026\24-8026_E-111 - 1ST FLR LTG PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 EXISTING FIRST FLOOR LIGHTING PLAN
SCALE: 1/8"=1'-0"
4 PARTIAL FIRST FLOOR LIGHTING PLAN AT SHARED OFFICE
SCALE: 1/4"=1'-0"

REFERENCE NOTES

1. EXTEND EXISTING LIGHTING BRANCH CIRCUIT IN THIS ROOM TO NEW LIGHT FIXTURES AND ASSOCIATED CONTROLS.

2. REPLACE EXISTING EXIT SIGN WITH EMERGENCY WITH NEW.

3. REMOVE WALL MOUNTED EXIT SIGN. PROVIDE NEW CEILING MOUNT EXIT SIGN AT NEW LOCATION. EXTEND EXISTING BRANCH CIRCUIT AT NEW LOCATION.

4. REPLACE EXISTING OCCUPANCY SENSOR WITH NEW ULTRASONIC OCCUPANCY SENSOR.

5. THESE SWITCHES CONTROL THE EXISTING DOWNLIGHTS AT OPEN OFFICE. LABEL SWITCHES.

6. REPLACE EXISTING EMERGENCY LIGHTING WITH NEW.

7. PROVIDE NEW EMERGENCY LIGHTING AT MID STAIR LANDING.

EXTEND EXISTING BRANCH CIRCUIT.

8. EXISTING EMERGENCY LIGHTING WAS CONNECTED TO AN OUTLET.

DISCONNECT AND REMOVE AND EXTEND EXISTING BRANCH CIRCUIT FROM EXISTING LIGHT IN THE SAME ROOM.

9. PROVIDE NEW EXTERIOR EMERGENCY LIGHTING EXTEND EXISTING

BRANCH CIRCUIT FROM NEAREST UNSWITCHED LIGHTING BRANCH
CIRCUIT.

10. PROVIDE NEW INTERIOR EMERGENCY LIGHTING. EXTEND EXISTING BRANCH CIRCUIT FROM UNSWITCHED LIGHTING BRANCH CIRCUIT.

11. PROVIDE NEW INTERIOR EXIT SIGN WITH EMERGENCY LIGHTING.

EXTEND EXISTING BRANCH CIRCUIT FROM UNSWITCHED LIGHTING BRANCH CIRCUIT.

12. EXISTING SWITCH TO BE RELOCATED TO NEW WALL. EXTEND LIGHT EXISTING BRANCH CIRCUIT TO NEW LOCATION. BLANK EXISTING SWITCH LOCATION. PROVIDE NEW OCCUPANCY WALL SWITCH.

LIGHTING FIRST FLOOR PLAN
E-111

PARTIAL FIRST FLOOR
3 LIGHTING PLAN AT RESTROOMS SCALE: 1/4"=1'-0"
NORTH

PARTIAL FIRST FLOOR
2 LIGHTING PLAN AT LOBBY
SCALE: 1/4"=1'-0"
5 LIGHTING PLAN AT STORAGE 11
SCALE: 1/4"=1'-0"PARTIAL FIRST FLOOR
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L

Page 278 of 1531 ends

UP
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
3 -
2 -

MEETING
ROOM
202

PUBLIC AFFAIRS

MANAGER
205
BOS.

MANAGER
208
BREAK
ROOM
207
INT. AFFAIRS
LIEUT.
224
MENS
129
WOMENS
222
HALL
STAIRS
144
SERVER
216
EQUIP.
220
BREAK
ROOM
215
CHIEF
214C
ADMIN
214A
DEPT.

CHIEF
213
DEPT.

CHIEF
ELEV. 211
MECH
112
COPY
ROOM
210
ELEV.

CONF.
202

TRAIN/HIRING

MANAGER
208
CRIME

ANALYST
209
(NL)
(NL)
(NL)
(NL)
(NL)
2 (NL)
(TBR) (TBR)
(TBR)
(TBR)
(EXR) (TBR)
3 3
(EXR)
(EXR)
(EXR)
(E)
XM
4 4
4 4
4 4 XM
(TBR)
(TBR)
(E) (E)
(E) (E)(E) (E)
(E) (E)(E) (E)
(E) (E)
(E) (E) (E)
(E) (E) (E) (E) (E) (E)(E)
(E) (E) (E) (E)(E) (E) (E) (E)
(E)(E)
(E) (E) (E)
(E)
(E)
(E) (E)(E) (E)
(E)(E) (E)
(E)
(E)
(E)
(E)
(E)
(E) (E)
(E) (E)
(E)
(E) (E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(TBR)
(TBR)
(E)
(E) (E) (E)
(E) (E)
(E)
(E)
(E) (E)
(E)
(E)
(N) XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
4 2
(N) XM(CLG)
4 (E)
(E) (E)
(E) (E) (E)
(E) (E)
(E)(E) (E)
(E) (E)
(E) (E)
(E)
(E)
WS
OS
WS
OS
WS,D
RPP
WS
RPP

WS WS,D
WS,D
aa
a a b b
b b
b
b
b
a
1 1
CHIEF
214C
ADMIN
214A
(EXN)
W1
D1
D1
D1
D1 D1
D1
D1
D1
W2
OS
LV
OS
LV
LV LV
1 1
OS
LV
PP
OS
LV

LV LV LV
MENS
129
WOMENS
222
JAN.
(EXN)
(EXN)
5 6
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:42pm - Chris - K:\ENG\2024\24-8026\24-8026_E-112 - 2ND FLR LTG PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 EXISTING SECOND FLOOR LIGHTING FLOOR PLAN
SCALE: 1/8"=1'-0"
3 PARTIAL SECOND FLOOR LIGHTING PLAN @ ADMIN/CHIEF SCALE: 1/4"=1'-0" BATTERY POWERD WALL DIMMER, 1 GANG
1-POLE 0-10V DIMMING (NLIGHT AIR #RPODB DX)
WS
D,WS
WIRELESS POWER RELAY PACK. 0-10V DIMMING
(NLIGHT AIR #RPP20)
RPP
WS
OS

CEILING OCC SENSOR BATTERY POWERED
(NLIGHT AIR #RCMSB 7 AR)

LIGHTING CONTROL SYMBOLS LEGEND
(EXR) = EXISTING TO BE RELOCATED(EXN) = EXISTING NEW LOCATION(E) = EXISTING (E) EXISTING SWITCH TO REMAIN(TBR) EXISTING SWITCH TO BE REMOVED

LIGHTING SECOND FLOOR PLAN
E-112

PARTIAL SECOND FLOOR
2 LIGHTING PLAN AT RESTROOMS
SCALE: 1/4"=1'-0"

REFERENCE NOTES

1. EXTEND EXISTING LIGHTING BRANCH CIRCUIT IN THIS ROOM TO NEW LIGHT FIXTURES AND ASSOCIATED CONTROLS.

2. REPLACE EXISTING EMERGENCY LIGHTING WITH NEW.

3. EXISTING SWITCH TO REPLACE WITH NEW DEVICE AND COVER PLATE.

4. PROVIDE NEW EMERGENCY LIGHT. EXTEND BRANCH CIRCUIT FROM UNSWITCH LIGHTING BRANCH CIRCUIT.

5. NEW LOCATION OF EXISTING EXIT SIGN. COVER CHEVRON.

INTERCEPT EXISTING BRANCH CIRCUIT FROM OLD LOCATION AND EXTEND TO NEW LOCATION.

6. NEW LOCATION OF EXISTING LIGHT. INTERCEPT EXISTING BRANCH CIRCUIT FROM OLD LOCATION AND EXTEND TO NEW LOCATION.

NORTH
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 279 of 1531 ends

3.4 2.42.12.55.1

8.8 4.4 2.7

0.8 1.0

0.90.8 5.83.1

2.5 2.7

5.1 0.3 0.3 1.0

0.8 0.20.7 2.4

4.2 3.7

2.3 1.2 1.1 2.0 7.4 10.4 9.8 6.2 1.6 0.9 1.7 4.4 10.7

4.5 1.5

2.6 2.9

9.1 9.7

6.5 7.1 7.2 1.2

4.14.53.73.43.7 1.02.52.52.83.6

1.2 8.9 6.0 5.6

1.62.93.13.64.6 6.5 4.2 2.4 1.5 1.2

1.10.80.60.40.40.30.50.91.42.01.7 1.4 0.9 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.6 0.9 1.3 1.8 3.1 4.4 5.2

5.20.70.50.81.67.0 0.9 0.5 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.9 3.3

1.41.71.20.80.60.81.21.71.30.8 0.6 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.7

0.91.51.51.00.70.71.11.82.72.9 1.02.04.19.3

1.1 1.2 1.8 3.0 5.2

3.42.42.12.55.1 8.8 4.4 2.7

0.8 1.0

0.90.8 5.83.1

2.5 2.7

5.1 0.3 0.3 1.0

0.8 0.20.7 2.4

4.2 3.7

2.3 1.2 1.1 2.0 7.4 10.4 9.8 6.2 1.6 0.9 1.7 4.4 10.7

4.5 1.5

2.6 2.9

9.1 9.7

6.5 7.1 7.2 1.2

4.14.53.73.43.7 1.02.52.52.83.6

1.2 8.9 6.0 5.6

1.62.93.13.64.6 6.5 4.2 2.4 1.5 1.2

1.10.80.60.40.40.30.50.91.42.01.7 1.4 0.9 0.6 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.6 0.9 1.3 1.8 3.1 4.4 5.2

5.20.70.50.81.67.0 0.9 0.5 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.9 3.3

1.41.71.20.80.60.81.21.71.30.8 0.6 0.4 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.4 0.7

0.91.51.51.00.70.71.11.82.72.9 1.02.04.19.3

1.1 1.2 1.8 3.0 5.2
X2
(N)XM
XM (N)
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N) XM
CLG
(N)XM
X2
(EXN)
(N)XM
(N)XM
(N) XM
(N)X2
(N)
X1
X2
(N) XM
CLG
11 A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
(N)
(N)XM
(N)XME
(N)XME
(N)XME

14.1 1.9 1.1 1.1 2.8 13.2 11.1 2.6 1.3 1.1

1.24.42.21.81.71.92.24.0 4.21.60.90.90.80.81.39.1

19.7 4.0

2.0 1.1 1.1 1.1 1.1 2.5

3.12.27.2 2.8 2.5 3.5

1.82.61.30.70.60.71.13.23.9 4.3 1.7 1.0 1.0 1.0 1.4 3.7

19.2 12.4

4.9 2.0 3.1 16.8

14.1 1.9 1.1 1.1 2.8 13.2 11.1 2.6 1.3 1.1

1.24.42.21.81.71.92.24.0 4.21.60.90.90.80.81.39.1

19.7 4.0

2.0 1.1 1.1 1.1 1.1 2.5

3.12.27.2 2.8 2.5 3.5

1.82.61.30.70.60.71.13.23.9 4.3 1.7 1.0 1.0 1.0 1.4 3.7

19.2 12.4

4.9 2.0 3.1 16.8

XM (EXN)
4 4
(E)
(N) XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N)XM(CLG)
(N) XM(CLG)
(N)XM(CLG)
XM
UP
UP
11 A
B
G
4 5 14 15 18
18 E
D
6 13
8 11
3 7 9 10 12 16
F
22 C
1717
(E)
1 1
(E)
San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:42pm - Chris - K:\ENG\2024\24-8026\24-8026_E-113 - LTG EM PHOTOMETRICS PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
1 FIRST FLOOR EM PHOTOMETRIC PLAN
SCALE: 1/8"=1'-0"

LIGHTING EMERGENCY PHOTOMETRIC PLAN
E-113
NORTH
2 SECOND FLOOR EM PHOTOMETRIC PLAN
SCALE: 1/8"=1'-0"
CBC 1008.3.5 ILLUMINATION LEVEL UNDER EMERGENCY
POWER

EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGE TO PROVIDE INITIAL ILLUMINATION THAT IS NOT LESS THAN AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY POINT0.1 FOOT-CANDLE MEASURE ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT-CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END OF THEEMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MINIMUM ILLUMINATION UNIFORMITY RATION OF 40 TO 1 SHALL NOT BE EXCEEDED.

LEGEND
EMERGENCY LIGHT WITH 90 MINUTE BATTERY BACK-UPEXIT SIGN WITH EMERGENCY LIGHT AND 90 MINUTE BATTERY BACK-UPEXIT SIGN WITH 90 MINUTE BATTERY BACK-UP

REFERENCE NOTES

1. REFER TO 1ST FLOOR STAIRWELL FOR LIGHT LEVELS UNDER
EMERGENCY.
1 R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 280 of 1531 ends

1 1
A A
B B
G G
4 5 14 15 18
18 E E
D D
6 13
8 11
3 7 9 10 12 16
F F
22 C C
1717
DS
1 (ODU)
208V, 1ɸ

16.5 MCA
20 MOCP
1 C-39/41
2 San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:42pm - Chris - K:\ENG\2024\24-8026\24-8026_E-121 - ROOF PLN.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT

ELECTRICAL ROOF PLAN
E-121

REFERENCE NOTES

1. PROVIDE LINE VOLTAGE CONNECTION TO MECHANICAL UNIT.

ELECTRICAL CONTRACTOR SHALL COORDINATE EXACT LOCATION
WITH MECHANICAL PLANS AND PROVIDE 2-POLE, NEMA 3R
DISCONNECT PER MANUFACTURER'S REQUIREMENTS.

2. NEW DEDICATED 20A BRANCH CIRCUIT TO EXISTING PANEL "C".

PROVIDE NEW 20A/2P CIRCUIT BREAKER IN PANEL AS DESIGNATED TO MATCH EXISTING. PROVIDE (1) 3/4" CONDUIT WITH (2) #12 THWN AND (1) #12 CU GROUND.

NORTH
SCALE:

POWER SIGNAL SECOND FLOOR PLAN
3/16"=1'-0"
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 281 of 1531 ends

San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:42pm - Chris - K:\ENG\2024\24-8026\24-8026_E-201 - ELEC DETAILS.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
EJ

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
3 TYPICAL DEVICE ADA MOUNTING HEIGHTS SCALE: NTS
34" MAXIMUM
46" MAXIMUM - SIDE REACH
24" MAXIMUM

MOUNTING HEIGHT OVER OBSTRUCTION
15"

MINIMUM

TO BOTTOM OF

WIRING DEVICE

OUTLET BOX

TO TOP OF SWITCH,THERMOSTAT, OUTLET,

OR CONTROL DEVICE

TO TOP OF SWITCH,THERMOSTAT, OUTLET,

OR CONTROL DEVICE

FINISH FLOOR FINISH FLOOR
* NO FORWARD REACH ALLOWED
48"

MAXIMUM

UNLESS KNEE SPACE IS PROVIDED
* 27" CLR
FIXTURES LESS THAN 50 LBS

PROVIDE POSITIVE FASTENING
TO T-BAR GRID AT EACH END OF FIXTURE.

ATTACH WITH #8 FLAT HEAD SHEET METAL SCREW

T-BAR CEILING GRID,

SEE ARCHITECTURAL
REFLECTED CEILINGPLANS.

LIGHTING FIXTURE PER
FIXTURE SCHEDULES.

REFER TO ARCHITECTURAL

DETAILS FOR ATTACHMENT TO
STRUCTURE.

CEILING SUPPORT
WIRES.

MINIMUM (3) TIGHT TURNS
IN 1-1/2".

HEAVY DUTY GRID SYSTEM
PROVIDE #12 GA. SLACK SUPPORT WIRES AT 2

DIAGONALLY OPPOSITE CORNERS FOR FIXTURES
UP TO 50 LBS. (FIXTURES ABOVE 50 LBS. SHALL BE
INDEPENDENTLY SUPPORTED AS NOTED BELOW).

AT STUD WALL

AT CMU WALL

REFERENCE NOTES
HEIGHTSEE ARCH. PLANSFOR MOUNTING

OUTLET BOX
PROVIDE #10x1" HEX HEAD

SELF-TAPPING SCREWS AT FIXTURE
MOUNTING POINTS. (MINIMUM OF 2)

TO BACKING OR WALL
STUDS

METAL WALL STUD,
SEE ARCH. PLANS.

WALL FINISH, SEE
ARCH. PLANS.

WALL STUD BACKING
PER 14-X/S105.

1. SMALL SURFACE MOUNTED LIGHT
FIXTURE. (20 LBS. OR LESS)

2. CONCRETE MASONRY WALL.

3. 3/8" DIA. HILTI KB3 , PER ICC ESR-2302.

PROVIDE MINIMUM 2-1/2" EMBEDMENT.

NOTE:

FLUSH MOUNTED OUTLET BOX IS NOT
SHOWN FOR CLARIFICATION.

LIGHTING FIXTURE

PER FIXTURE
SCHEDULE ONSHEET X/E105.

PLAN
PLAN

FIRE PUTTY IS NOT REQUIRED IF

ONLY ONE BOX IS INSTALLED ON
EITHER SIDE OF 100 SF OF WALL.
213

WRAP FIRE PUTTY PADS

OVER FITTING

WRAP FIRESTOP PUTTY
PADS OVER ENTIRE BOX.

OVERLAP ON TOP, BOTTOM
& SIDES.OUTLET BOX. REFER TO

PLANS AND SPECIFICATION
FOR TYPE, SIZE & QUANTITY.

PROVIDE 1/4" BEAD OF

INSULATING PUTTY TO SEAL

BETWEEN PLASTER RING &

DRYWALL

FILL GAP BETWEEN

PLASTER RING ANDDRYWALL WITH PLASTER
PLASTER RING. REFER TO

ARCHITECTURAL PLANS FOR

WALL TYPE AND PROVIDE

RING DEPTH TO MATCHDRYWALL DEPTH

FLUSH MOUNTED
J-BOX

FINISH WALL
6 DEVICE INSTALLATION - RATED WALLS SCALE: NTS5 LAY-IN BAR FIXTURE MOUNTING DETAIL SCALE: NTS4 SURFACE MOUNT FIXTURE DETAIL SCALE: NTS 9 IMAGE AT ROOM 2028 IMAGE AT ROOM 2147 IMAGE AT ROOM 123 12 TYPICAL MODULAR FUNITURE FEED DETAIL10 IMAGE AT OPEN OFFICE FLOOR

LIQUID-TIGHT FLEXIBLE CONDUIT
90° CONDUIT CONNECTOR-REVERSIBLE
(PROTRUDES WIDTH OF CONDUIT)

CONNECTION DISTRIBUTION

HARNESS
INSET

BUILDING WALL TO PANEL BASE

LIQUID-TIGHT FLEXIBLE CONDUIT

PARTITION CONNECTION, SEE INSET

IF NOT PRE-PUNCHED, USE HOLE

SAW OR PUNCH TO MAKE HOLE
FOR FLEX FITTING. INSTALL

CABLES INTO FURNITURE CABLE
CHANNEL.

FLUSH, WALL MOUNTEDPOWER FEED J-BOX
WITH EXTENSION BOX.

SEE PLAN FOR NUMBER
OF CIRCUITS.

FLUSH, WALL MOUNTED

COMMUNICATIONS FEED

J-BOX WITH EXTENSION
BOX. SEE

COMMUNICATIONS PLAN
FOR NUMBER OF CABLES.

CARLON FLEX CONDUIT,

SAME SIZE AS RACEWAY IN

WALL, WITH
COMMUNICATIONS CABLE.

RECEPTACLE LOCATIONS

ELECTRICAL DETAILS
E-201
EXISTING 14-CAT6 CABLES. REMOVED CABLES AND DISCONNECT AT "MDF" IN ELECTRICALROOM. DO NOT CUT CABLES. 11 1 SCALE: NTS2
R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

LI F CA
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N
RO P D NA FESSIO L R E E Y T M. E
C
F
NO. 20823
E L TS
O E AT
E
IS GE
R
E
J

T FFE R
A
OR
L

T R I C

C LI F A
I A N
HOMNA
R
EE
GI N

RO P D NA FESSIO L

Page 282 of 1531 ends

San Luis Obispo, CA 93406
P.O. Box 1167 - 3562 Empleo St.

THOMA ELECTRIC, INC.

Phone: (805) 543-3850
[email protected]
Fax: (805) 543-3829
Sep 13, 2024 - 12:42pm - Chris - K:\ENG\2024\24-8026\24-8026_E-301 - T24 FORMS.dwg 2000577-04 1106 WALNUT TENANT IMPROVEMENT
CITY SPECIFICATION NO.

DATE:

PROJECT TITLE:

SHEET TITLE:

SHEET NO.

DESIGNED BY:DRAWN BY:

CHECKED BY:

APPROVED BY:

SCALE:

PLAN FILE NO. / LOCATION
As indicated
TR
6/20/2024
CJ
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
EXPIRES: 09/30/26
THOMA #24-8026
CJ
JT
TITLE 24 ENERGY FORMS - INTERIOR LIGHTING
E-301
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C

LI F CA
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L
R
E
E
Y T M. E
C
F
NO. 20823
E L

TS O E AT
E
IS GER
EJ
T
FF
E
R
A
OR
L

T R I C C LI F A
I A N
HOM
N
A

REE GI N
RO P D
NA

FESSIO L

Page 283 of 1531 ends
Page 284 of 1531 ends

SPECIAL PROVISIONS
FOR

CITY OF SAN LUIS OBISPO
1106 Walnut Tenant Improvements
Specification No. 2000577-04
NOVEMBER 2024

PUBLIC WORKS DEPARTMENT

ENGINEERING DIVISION
919 Palm Street
San Luis Obispo, CA 93401
(805) 781-7200

Page 285 of 1531 ends

1106 Walnut Tenant Improvements
Specification No. 2000577-04
Approval Date: November 12, 2024
<<Engineer of Record Stamp>>
<<Signature Date>>
<<Signature Date>>

Page 286 of 1531 ends

TABLE OF CONTENTS
NOTICE TO BIDDERS..................................................................................................... I BID SUBMISSION......................................................................................................................................I BID DOCUMENTS ....................................................................................................................................II PROJECT INFORMATION........................................................................................................................II QUALIFICATIONS....................................................................................................................................III AWARD ....................................................................................................................................................IV ACCOMMODATION..................................................................................................................................V BID FORMS ....................................................................................................................A BID ITEM LIST FOR 1106 WALNUT TENANT IMPROVEMENTS, SPECIFICATION NO. 2000577-

04...............................................................................................................................................................A LIST OF SUBCONTRACTORS................................................................................................................ C PUBLIC CONTRACT CODE SECTION 10285.1 STATEMENT.............................................................. D PUBLIC CONTRACT CODE SECTION 10162 QUESTIONNAIRE......................................................... D PUBLIC CONTRACT CODE SECTION 10232 STATEMENT................................................................. D LABOR CODE SECTION 1725.5 STATEMENTS ................................................................................... D NON-COLLUSION DECLARATION..........................................................................................................F BIDDER ACKNOWLEDGEMENTS.......................................................................................................... G QUALIFICATIONS.................................................................................................................................... H ATTACH BIDDER'S BOND TO ACCOMPANY BID...................................................................................I SPECIAL PROVISIONS.................................................................................................. 1 DIVISION I GENERAL PROVISIONS.......................................................................................................1 1 GENERAL...........................................................................................................................................1 3 CONTRACT AWARD AND EXECUTION...........................................................................................1 4 SCOPE OF WORK.............................................................................................................................2 5 CONTROL OF WORK........................................................................................................................2 8 PROSECUTION AND PROGRESS ...................................................................................................2 9 PAYMENT...........................................................................................................................................2 DIVISION XI MATERIALS .....................................................................................................................3 91 PAINT ...............................................................................................................................................3 DIVISION XII BUILDING CONSTRUCTION .............................................................................................3 99 BUILDING CONSTRUCTION...........................................................................................................3 DIVISION XIII APPENDICES....................................................................................................................3 APPENDIX A - FORM OF AGREEMENT ....................................................................... 0 APPENDIX B – SUPPLEMENTAL TECHNICAL SPECIFICATIONS ................................

APPENDIX C – CITY COMMUNICATION CABLING SPECIFICATIONS.........................

APPENDIX D – FURNITURE SCHEDULE .......................................................................

Page 287 of 1531 ends

APPENDIX E – LEAD AND ASBESTOS REPORT...........................................................

APPENDIX F – CONDENSER STRUCTURAL CALCULATIONS.....................................

Page 288 of 1531 ends

NOTICE TO BIDDERS
i

NOTICE TO BIDDERS

BID SUBMISSION
Sealed bids will be received by the City of San Luis Obispo at the Public Works Administration Office located at 919 Palm Street, San Luis Obispo, California 93401, until 11:00 a.m. on December 19, 2024
at which time they will be publicly opened and read aloud. Public bid opening may also be viewed via Microsoft Teams video conference and conference call. Use the following link:
or join by phone with this number: (209)645-4165 with Conference ID:XXXXXXXX Submit bid in a sealed envelope plainly marked:
1106 Walnut Tenant Improvements, Specification No. 2000577-04 Any bid received after the time and date specified will not be considered and will be returned to the bidder unopened. Bids received by Fax or Email will not be considered.

By submission of bid you agree to comply with all instruction and requirements in this notice and the contract documents.

All bids must be submitted on the Bid Item List form(s) provided and submitted with all other Bid Forms included in these Special Provisions.

Each bid must be accompanied by either a:

1. certified check

2. cashier's check

3. bidder's bond
made payable to the City of San Luis Obispo for an amount equal to ten percent of the bid amount as a guaranty. Guaranty will be forfeited to the City San Luis Obispo if the bidder, to whom the contract is awarded, fails to enter into the contract.

The City of San Luis Obispo reserves the right to accept or reject any or all bids or waive any informality in a bid.

All bids are to be compared based on the City Engineer's estimate of the quantities of work to be done, as shown on the Bid Item List.

Page 289 of 1531 ends

NOTICE TO BIDDERS

NOTICE TO BIDDERS
ii
Bids will only be accepted from bidders that are licensed in compliance with the provisions of Chapter 9, Division III of Business and Professions Code.

The award of the contract, if awarded, will be to the lowest responsive bid submitted by a responsible contractor whose bid complies with the requirements prescribed. If the contract is awarded, the contract will be awarded within 60 calendar days after the opening of the bids.

Failure to raise defects in the notice to bidders or bid forms prior to bid opening constitute a waiver of those defects.

BID DOCUMENTS
A copy of the plans and special provisions may be downloaded, free of charge, from the City’s website at:
www.slocity.org/government/department-directory/public-works/public-works-bidsproposals No printed copies are available for purchase at the City office.

Standard Specifications and Engineering Standards referenced in the Special Provisions may be downloaded, free of charge, from the City’s website at:
www.slocity.org/government/department-directory/public-works/documentsonline/construction-documents You are responsible to obtain all issued addenda prior to bid opening. Addenda will be available to download at the City’s website listed above or at the office of the City Engineer.

Contact the project manager, Sandra Golonka at 805-781-7239 or the Public Works Department at (805) 781-7200 prior to bid opening to verify the number of addenda issued.

PROJECT INFORMATION
In general, the project consists of remodeling and tenant improvement of existing interior office space.

The project estimated construction cost is $1,470,000
Contract time is established as 80 working days.

The fixed liquidated damages amount is established at $500 per day for failure to complete the work within the contract time.

Page 290 of 1531 ends

NOTICE TO BIDDERS

NOTICE TO BIDDERS
iii
In compliance with section 1773 of the Labor Code, the State of California Department of Industrial Relations has established prevailing hourly wage rates for each type of workman. Current wage rates may be obtained from the Division of Labor at:
https://www.dir.ca.gov/oprl/DPreWageDetermination.htm
This project is subject to compliance monitoring and enforcement by the Department of Industrial Relations.

There will be a MANDATORY walkthrough on Wednesday, December 4, 2024 at 11 am. Prime contractors wishing to submit a bid proposal are required to attend and sign in at the meeting. Bidders must meet City Staff at 1106 Walnut Street in San Luis Obispo, California.

QUALIFICATIONS
You must possess a valid Class B Contractor's License at the time of the bid opening.

You and any subcontractors required to pay prevailing wage must be registered with the Department of Industrial Relations pursuant to Section 1725.5 of the Labor Code.

You must have experience constructing projects similar to the work specified for this project. Provide three similar reference projects completed as either the prime or subcontractor. All referenced projects must have been completed within the last five years from this project’s bid opening date.

One of the three reference projects must have been completed under contract with a city, county, state or federal government agency as the prime contractor.

Two of the referenced projects must be for tenant improvements.

One of the referenced projects must be for an office rehabilitation with electrical work.

Failure to provide reference projects as specified in this section and as required on the qualification form is cause to reject a bid as being non-responsive.

The City reserves the right to reject any bid based on non-responsiveness if a bidder fails to provide a bid that complies with all bidding instructions.

The City reserves the right to reject a responsive bid based on the non-responsibility of the bidder if the Director of Public Works or Designee finds, after providing notice and a hearing to the bidder, that the bidder lacks the

1. knowledge

Page 291 of 1531 ends

NOTICE TO BIDDERS

NOTICE TO BIDDERS
iv

2. experience,

3. or is otherwise not responsible as defined in Section 3.24 of the San Luis Obispo Municipal Code to complete the project in the best interest of the City.

Rejected bidders may appeal this determination. Appeal must comply with the requirements in this Notice to Bidders.

It is the City of San Luis Obispo’s intent to award the contract to the lowest responsive bid submitted by a responsible bidder. If in the bidder’s opinion the contract has been or may be improperly awarded, the bidder may protest the contract award.

Protests must be filed no later than five working days after either:

1. bid opening date

2. notification of rejected bid.

Protest must be in writing and received by the project manager located at:
919 Palm Street
San Luis Obispo, CA 93401.

Valid protests must contain the following information:

1. the reasons for the protest

2. any supporting documentation

3. the ruling expected by the City to remedy the protest.

Any protest not containing all required information will be deemed invalid and rejected.

The City will consider additional documentation or other supporting information regarding the protest if submitted in compliance to the specified time limits. Anything submitted after the specified time limit will be rejected and not be considered.

The Director of Public Works or Designee may request additional information to be submitted within three days of the request, unless otherwise specified, and will notify the protester of ruling within ten days of determination.

If the protester is not satisfied with ruling, the protester may appeal the ruling to the City Council in compliance with Chapter 1.20 of the City of San Luis Obispo Municipal Code.

Pursuant to the Public Records Act (Government Code, § 6250, et seq.), the City will make public records available upon request.

AWARD
The lowest bidder will be determined using the TOTAL PROJECT BID.

As a condition to executing a contract with the City, two bonds each equal to one hundred percent of the total contract price are required in compliance with Section 3-1.05 of the Standard Specifications.

Page 292 of 1531 ends

NOTICE TO BIDDERS

NOTICE TO BIDDERS
v
You may substitute securities for moneys withheld under the contract in compliance with the provisions of the Public Contract Code, Section 10263.

ACCOMMODATION
If any accommodations are needed to participate in the bid process, please contact Allie Genard at (805) 781-7200 or by Telecommunications Device for the Deaf at (805) 781- 7107. Requests should be made as early as possible in the bidding process to allow time for accommodation.

Page 293 of 1531 ends

BID FORMS
A

BID FORMS
All bid forms must be completed and submitted with your bid. Failure to submit these forms and required bid bond is cause to reject the bid as nonresponsive. Staple all bid forms together.

THE UNDERSIGNED, agrees that they have carefully examined:

1. the location of the proposed work

2. the plans and specifications

3. read the accompanying instructions to bidders
and propose to furnish all:

1. materials

2. labor
to complete all the required work satisfactorily in compliance with

3. plans

4. specifications

5. special provisions
for the prices set forth in the bid item list:

BID ITEM LIST FOR 1106 WALNUT TENANT IMPROVEMENTS,
SPECIFICATION NO. 2000577-04
Item Item Unit of Estimated Item Price Total
No. SS(1) Description Measure Quantity (in figures) (in figures) 1 99 1
st Floor Office Rehabilitation LS 1 ---
2 99 2
nd Floor Office Rehabilitation LS 1 ---
3 99 Replace Existing Exterior
Signage LS 1 ---
4 99 Flooring Removal and
Replacement SQFT 9400
5 99 Furniture Purchase and
Installation LS 1 ---
6 99 Relocate 2nd Floor Cubicles to 1st
Floor LS 1 ---
7 99 Ductless Split HVAC System for
2 nd Floor Server Room LS 1 ---
8 91,99 Painting LS 1 ---
9 99 Electrical and Communication
Improvements LS 1 ---
10 99 1
st Floor Restroom Rehabilitation LS 1 ---
11 99 2
nd Floor Restroom Rehabilitation LS 1 ---
12 99 Remove and Replace Casework
for 2nd Floor Breakroom LS 1 ---
13 99 Hydration Station EA 1
Bid Total (or Base Bid) $
Company Name:

Page 294 of 1531 ends

BID FORMS

BID FORMS
B
(1) refers to section in the Standard Specifications, with modifications in the Special Provisions, that describe required work.
(S) Specialty item per Section 5-1.13A SUBCONTRACTING, General of the Standard Specifications (F) final pay item per Section 9-1.02A

Page 295 of 1531 ends

BID FORMS

BID FORMS
C

LIST OF SUBCONTRACTORS
Pursuant to Section 4100 of the Public Contracts Code and section 2-1.33C of the standard specifications, the Bidder is required to furnish the following information for each Subcontractor performing more than 1/2 percent (0.5%) of the total base bid. Do not list alternative subcontractors for the same work. Subcontracting must not total more than fifty percent (50%) of the submitted bid except as allowed in section 5-1.13 of the standard specifications.

For Streets & Highways projects, subcontractors performing less than ten thousand dollars ($10,000) worth of work need not be mentioned. Subcontractors required to pay prevailing wage, must be registered with the Department of Industrial Relations pursuant to Labor Code section 1725.5 to be listed.

NOTE: If there are no subcontractors, write “NONE” and submit with bid.

Name Under Which
Subcontractor is Licensed License Number
DIR Public
Works
Registration
Number
Address and Phone
Number of Office, Mill or
Shop
Specific
Description of
Subcontract
% of
Total
Base
Bid
Attach additional sheets as needed.

Page 296 of 1531 ends

BID FORMS

BID FORMS
D
PUBLIC CONTRACT CODE SECTION 10285.1 STATEMENT
In compliance with Public Contract Code Section 10285.1 (Chapter 376, Stats. 1985), the bidder hereby declares under penalty of perjury under the laws of the State of California that the bidder, or any subcontractor to be engaged by the bidder, has ____, has not ____ been convicted within the preceding three years of any offenses referred to in that section, including any charge of fraud, bribery, collusion, conspiracy, or any other act in violation of any state or federal antitrust law in connection with the bidding upon, award of, or performance of, any public works contract, as defined in Public Contract Code Section 1101, with any public entity, as defined in Public Contract Code Section 1100, including the Regents of the University of California or the Trustees of the California State University. The term "bidder" is understood to include any partner, member, officer, director, responsible managing officer, or responsible managing employee thereof, as referred to in Section 10285.1.

NOTE: The bidder must place a check mark after "has" or "has not" in one of the blank spaces provided. The above Statement is part of the Bid. Signing this Bid on the signature portion constitute signature of this Statement. Bidders are cautioned that making a false certification may subject the certifier to criminal prosecution.

PUBLIC CONTRACT CODE SECTION 10162 QUESTIONNAIRE
In compliance with Public Contract Code Section 10162, the Bidder must complete, under penalty of perjury, the following questionnaire:

Has the bidder, any officer of the bidder, or any employee of the bidder who has a proprietary interest in the bidder, ever been disqualified, removed, or otherwise prevented from bidding on, or completing a federal, state, or local government project because of a violation of law or a safety regulation?
Yes No
If the answer is yes, attach a letter explaining the circumstances PUBLIC CONTRACT CODE SECTION 10232 STATEMENT
In compliance with Public Contract Code Section 10232, you hereby state under penalty of perjury, that no more than one final unappealable finding of contempt of court by a federal court has been issued against you within the immediately preceding two-year period because of your failure to comply with an order of a federal court which orders you to comply with an order of the National Labor Relations Board.

LABOR CODE SECTION 1725.5 STATEMENTS
The bidder has delinquent liability to an employee or the state for any assessment of back wages or related damages, interest, fines, or penalties pursuant to any final judgment, order, or determination by a court or any federal, state, or local administrative agency, including a confirmed arbitration award. Any judgment, order, or determination that is

Page 297 of 1531 ends

BID FORMS

BID FORMS
E
under appeal is excluded, provided that the contractor has secured the payment of any amount eventually found due through a bond or other appropriate means.

Yes No
The bidder is currently debarred under Section 1777.1 or under any other federal or state law providing for the debarment of contractors from public works.

Yes No
NOTE: The above Statements and Questionnaire are part of the Bid. Signing this Bid on the signature portion constitute signature of this Statement and Questionnaire. Bidders are cautioned that making a false certification may subject the certifier to criminal prosecution.

Page 298 of 1531 ends

BID FORMS

BID FORMS
F

NON-COLLUSION DECLARATION
I, , declare that
I am of ,
the party making the foregoing bid that the bid is not made in the interest of, or on behalf of, any undisclosed person, partnership, company, association, organization, or corporation; that the bid is genuine and not collusive or sham; that the bidder has not directly or indirectly induced or solicited any other bidder to put in a false or sham bid, and has not directly or indirectly colluded, conspired, connived, or agreed with any bidder or anyone else to put in a sham bid, or that anyone refrained from bidding; that the bidder has not in any manner, directly or indirectly, sought by agreement, communication, or conference with anyone to fix the bid price of the bidder or any other bidder, or to fix any overhead, profit, or cost element of the bid price, or of that of any other bidder, or to secure any advantage against the public body awarding the contract of anyone interested in the proposed contract; that all statements contained in the bid are true; and, further, that the bidder has not, directly or indirectly, submitted his or her bid price or any breakdown thereof, or the contents thereof, or divulged information or data relative thereto, or paid, and will not pay, any fee to any corporation, partnership, company association, organization, bid depository, or to any member or agent thereof to effectuate a collusive or sham bid.

Executed on , 20 , in __
I declare under penalty of perjury under the laws of the State of California that the foregoing is true and correct.
(Signature and Title of Declarant)
(SEAL)
Subscribed and sworn to before me
this _______day of _________, 20_____
Notary Public
Company Name:____________________

Page 299 of 1531 ends

BID FORMS

BID FORMS
G

BIDDER ACKNOWLEDGEMENTS
By signing below, the bidder acknowledges and confirms that this bid is based on the information contained in all contract documents, including the notice to bidders, plans, specifications, special provisions, and addendum number(s) . (Note: You are responsible to verify the number of addenda prior to the bid opening.)
The undersigned further agrees that in case of default in executing the required contract, with necessary bonds, within eight days, (not including Saturdays, Sundays, and legal holidays), after having received a mailed notice that the contract is ready for signature, the proceeds of the check or bond accompanying his bid will become the property of the City of San Luis Obispo.

Licensed in accordance with an act providing for the registration of contractors, License No. , Expiration Date .

The above statement is made under penalty of perjury, and any bid not containing this information "will be considered non-responsive and will be rejected” by the City.

Signature of Bidder
(Print Name and Title of Bidder)
DIR– Public Works
Registration No:

Business Name (DBA):

Owner/Legal Name:

Indicate One: Sole-proprietor  Partnership Corporation List Partners/Corporate Officers:

Name Title
Name Title
Name Title
Business Address
Street Address
Mailing Address
City, State, Zip Code
Phone Number
Fax Number
Email Address
Date

Page 300 of 1531 ends

BID FORMS

BID FORMS
H

QUALIFICATIONS
Failure to furnish complete reference information ON THIS FORM, as specified in this project’s Notice to Bidders and indicated below, is cause to reject the bid. Additional information may be attached but is not a substitute for this form.

Reference Number 1
Customer Name & Contact Individual
Telephone & Email
Project Name (Site Address):

Is this similar to the project being bid
and did this project include tenant
improvement activity? Yes □
No □
Describe the services provided and how this project is similar to that which is being bid:

Date project completed:

Was this contract for a public agency?
Yes □ No □
Reference Number 2
Customer Name & Contact Individual
Telephone & Email
Project Name (Site Address):

Is this similar to the project being bid
and did this project include tenant
improvement activity? Yes □
No □
Describe the services provided and how this project is similar to that which is being bid:

Date project completed:

Was this contract for a public agency?
Yes □ No □
Reference Number 3
Customer Name & Contact Individual
Telephone & Email
Project Name (Site Address):

Is this similar to the project being bid
and did this project include office
rehabilitation with electrical work?
Yes □ No □
Describe the services provided and how this project is similar to that which is being bid:

Date project completed:

Was this contract for a public agency?
Yes □ No □

Page 301 of 1531 ends

BID FORMS

BID FORMS
I

ATTACH BIDDER'S BOND TO ACCOMPANY BID
Know all men by these presents:

That we ____________________________________________, AS PRINCIPAL, and _______________________________________________________, AS SURETY, are held and firmly bound unto the City of San Luis Obispo in the sum of:
____________________________________________________ Dollars (_____________) to be paid to said City or its certain attorney, its successors and assigns; for which payment, well and truly to be made, we bind ourselves, our heirs, executors and administrators, successors or assigns, jointly and severally, firmly by these presents:

THE CONDITION OF THIS OBLIGATION IS SUCH, that if the certain bid of the above bounden ______________________________________________________________________ to construct ___________________________________________________________________ (insert name of street and limits to be improved or project) dated _____________________ is accepted by the City of San Luis Obispo, and if the above bounden _______________________________________________________, his heirs, executors, administrators, successors, and assigns shall duly enter into and execute a contract for such construction and shall execute and deliver the two bonds described within ten (10) days (not including Saturdays, Sundays, or legal holidays) after the above bounden,
______________________________________________________, has received notice by and from the said City of San Luis Obispo that said contract is ready for execution, then this obligation shall become null and void; otherwise, it shall be and remain in full force and virtue.

IN WITNESS WHEREOF, we hereunto set our hands and seals this ___ day of ______, 20____.

Bidder Principal:

Signature Date
Title:

Surety:

Bidder's signature is not required to be notarized. Surety's signature must be notarized.

Equivalent form may be substituted
(Rev. 6-30-14)

Page 302 of 1531 ends

SPECIAL PROVISIONS
1 SPECIAL PROVISIONS

ORGANIZATION
Special provisions are under headings that correspond with the main section heading of the Standard Specifications. Each special provision begins with a revision clause that describes or introduces a revision to the Standard Specifications. Any paragraph added or deleted by a revision clause does not change the paragraph number of the Standard Specifications for any other reference to a paragraph of the Standard Specifications.

DIVISION I GENERAL PROVISIONS
1 GENERAL
Add to Section 1-1.01 GENERAL:

The work must be done in compliance with the City of San Luis Obispo, Department of Public Works:

1. 1106 Walnut Fencing Improvements Special Provisions

2. City of San Luis Obispo Standard Specifications and Engineering Standards – 2020 edition

3. State of California, Department of Transportation Standard Specifications and Standard Plans – 2015 edition
In case of conflict between documents, governing ranking must comply with section 5-

1.02 of the City of San Luis Obispo’s Standard Specifications. All work must conform to these Special Provisions and appendices, project plans, and the most current Building Codes. In the event of a conflict, the more stringent requirement shall apply.

Failure to comply with the provisions of these sections is a material breach of contract:

1. Sections 5 through 8 of the Standard Specifications

2. Section 12 through 15 of the Standard Specifications

3. Section 77-1 of the Standard Specifications

4. Section 81 of the Standard Specifications

5. authorized working hours

6. OSHA compliance
3 CONTRACT AWARD AND EXECUTION
Add Section 3-1.18B CONTRACT EXECUTION, Building Permit 3-1.18B Building Permit
The contractor must obtain a no-fee building permit from the Community Development Department. All requirements of the building permit shall be applied to the project. The contractor is responsible for coordinating inspection with the building division for the project. Request for the inspection must be scheduled 72 hours in advance of the required inspection.

Page 303 of 1531 ends

SPECIAL PROVISIONS

SPECIAL PROVISIONS
2 4 SCOPE OF WORK
Add to Section 4-1.03 WORK DESCRIPTION with:

Comply with the provisions of Section 91, and 99 for general, material, construction, and payment specifics.
5 CONTROL OF WORK
Add to Section 5-1.01 GENERAL with:

The Contractor is required to supply a weather safe storage area for all furniture to be reused if stored outside. The Contractor is allowed to use the 1106 Walnut parking lot for staging equipment and materials with the exception of the two rows in front of the main entrance.

City staff will vacate the building during construction.

Construction equipment will be allowed to be kept on-site after hours and over weekends provided it is fully contained within the fenced and secured work site and is not accessible to the public.

Work hours are restricted to 7:00 a.m. to 4:00 p.m. Monday through Friday.

Replace Section 5-1.32 AREAS FOR USE with:

Contractor shall be allowed to area for parking, staging, and construction within the property limits.
8 PROSECUTION AND PROGRESS
Replace the 1st paragraph in Section 8-1.02A SCHEDULE, General with:

Provide a Level 1 schedule for this work.

Add to Section 8-1.03 PRECONSTRUCTION CONFERENCE:

14. Schedule of Values for all lump sum bid items
9 PAYMENT
Add to Section 9-1.02A MEASUREMENT, General with:

Contractor must submit a Schedule of Values for all lump sum bid items of work at the Preconstruction Meeting in compliance with Section 9-1.16B. Payment application pay items shall match the bid item sheet and subcategories to a pay item will not be allowed.

Payment for Lump Sum items will be based on the percentage of acceptable work and the schedule of values for that item.

Page 304 of 1531 ends

SPECIAL PROVISIONS

SPECIAL PROVISIONS
3 Add to Section 9-1.03 PAYMENT SCOPE with:

Any item of work that does not have separate bid item is considered included in the project cost of work and no additional compensation will be paid.

DIVISION XI MATERIALS
91 PAINT
Add to Section 91-1.01 GENERAL:

Contractor must provide 1 gallon of each paint color used during the project for building maintenance staff. Cost for paint provided for building maintenance staff shall be included in the price of the Office Rehabilitation Lump Sum bid item.

See Appendix B for Technical Specifications
See Appendix C for City Communication Cabling Specifications See Appendix D for Furniture Schedule
See Appendix F: Condenser Structural Calculations

DIVISION XII BUILDING CONSTRUCTION
99 BUILDING CONSTRUCTION

DIVISION XIII APPENDICES
Add Section 100-1.01 APPENDICES:

Refer to Appendix A: Form of Agreement
Refer to Appendix B: Supplemental Technical Specifications Refer to Appendix C: City Communication Cabling Specifications Refer to Appendix D: Furniture Schedule
Refer to Appendix E: Lead and Asbestos Testing Report
Refer to Appendix F: Condenser Structural Calculations

Page 305 of 1531 ends

APPENDIX

APPENDIX
0 APPENDIX A - FORM OF AGREEMENT
THIS AGREEMENT, made on _____________, by and between the City of San Luis Obispo, a municipal corporation and charter city, San Luis Obispo County, California (hereinafter called the Owner) and COMPANY NAME (hereinafter called the Contractor).

WITNESSETH:

That the Owner and the Contractor for the consideration stated herein agree as follows:

ARTICLE 1, SCOPE OF WORK: The Contractor shall perform everything required to be performed, shall provide and furnish all of the labor, materials, necessary tools, expendable equipment, and all utility and transportation services required to complete all the work of construction of
NAME OF PROJECT, SPEC NO.
in strict compliance with the plans and specifications therefor, including any and all Addenda, adopted by the Owner, in strict compliance with the Contract Documents hereinafter enumerated.

It is agreed that said labor, materials, tools, equipment, and services shall be furnished and said work performed and completed under the direction and supervision and subject to the approval of the Owner or its authorized representatives.

ARTICLE II, CONTRACT PRICE: The Owner shall pay the Contractor as full consideration for the faithful performance of this Contract, subject to any additions or deductions as provided in the Contract Documents, the contract prices as follows:

Item
No.

Item Unit of
Measure
Estimated
Quantity
Item Price
(in figures)
Total
(in figures)

1. 2.

3. BID TOTAL: $ .00
Payments are to be made to the Contractor in compliance with and subject to the provisions embodied in the documents made a part of this Contract.

Should any dispute arise respecting the true value of any work omitted, or of any extra work which the Contractor may be required to do, or respecting the size of any payment to the Contractor, during the performance of this Contract, said dispute shall be decided by the Owner and its decision shall be final, and conclusive.

Page 306 of 1531 ends