REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
PURPOSES.

CONSTRUCTION

IS NOT TO BE USED FOR
2023, CA PE NO. 76832. IT
OF BRIAN W. AVON, APRIL

UNDER THE AUTHORITY

PURPOSE OF BIDDING

RELEASED FOR THE

THIS DOCUMENT IS
CHANGE DURING CONSTRUCTION.

DRAWINGS WILL BE PROVIDED AS A DESIGN
NOT FOR CONSTRUCTION. CONSTRUCTION
THIS DRAWING IS FOR BID PURPOSES ONLY.

PlotDate:4/5/202311:41:16AM
GENERAL NOTES:

8. FOR BIDDING PURPOSES, NOT FOR CONSTRUCTION.

7. FINAL TANK DESIGN TO BE DETERMINED BY THE TANK DESIGNER.

EVER APPLICABLE .

6. CONTRACTOR TO PROVIDE SHORING FOR ALL EARTHWORK WHERE SHALL BE CONTINUOUS WITH CLOSED LOOP ALL AROUND JOINTS.

5. FOR WATERSTOP SEE DETAILS S106/TYP & S107/TYP. WATERSTOP MINIMUM CONCRETE COVER AT TANK CONNECTION).

PLACEMENT OF CONCRETE FOR PIPE ENCASEMENT (VERIFY

4. INSPECTION OF REBAR BY ENGINEER REQUIRED PRIOR TO

2. PERIMETER 4000 PSF 1. CENTER 2000 PSF
i. ALLOWABLE GROSS BEARING PRESSURE
d. GEOTECHNICAL DESIGN DATA:
7-16 CH 21.2 METHOD 1. * SITE-SPECIFIC GROUND MOTION HAZARD ANALYSIS PER ASCE vii. LONG-PERIOD TRANSITION PERIOD, TL: 8 SECONDS (ANCHORED FLEXIBLE-BASE TANK)
vi. RESPONSE MODIFICATION FACTOR, R: 3.25 v. SEISMIC DESIGN CATEGORY: D iv. DESIGN SPECTRAL RESPONSE ACCELERATION, SD1*: 1.58g
iii. DESIGN SPECTRAL RESPONSE ACCELERATION, SDS*: 1.48g ii. SEISMIC IMPORTANCE FACTOR, Ie: 1.50 i. RISK CATEGORY: IV c. EARTHQUAKE DESIGN DATA (ASCE 7-16):
ii. EXPOSURE: C i. ULTIMATE DESIGN WIND SPEED, Vult (3-SEC GUST): 104 MPH b. WIND DESIGN DATA:
300 LBS CONCENTRATED LOAD.
a. ROOF LIVE LOAD: 40PSF (NON-REDUCIBLE) WITH A
FOR THE TANK DESIGN.

CODE. SEE SPECIFICATION 13027 FOR ADDITIONAL DESIGN CRITERIA STRUCTURAL DESIGN CRITERIA PER 2019 CALIFORNIA BUILDING

3. THE TANK DESIGN SHALL, AS A MINIMUM, MEET THE FOLLOWING

2. SEE ADDITIONAL NOTES ON SHEET 99S05.

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING 00S01. 99S07
68 STRUCTURAL

STORAGE TANK

SECTIONS AND DETAILS
8660F1099S07.dwg 8660F10
115'-0" (INSIDE DIAMETER)
TOW 625.00TOC 624.25
621.75

SPRING LINE
V
99S05 1/8" = 1'-0"
8660F1001S310
16" RW
OUTLET
16" RW
INLET
3- 3/8" = 1'-0"
8660F1001S310
4- 1/2" = 1'-0"
8660F1001S310
X
99S05 3/8" = 1'-0"
8660F1001S310

TANK OUTLET PIPE
W
99S05 1/8" = 1'-0"
8660F1001S310
1% SLOPE
3- 3- 4- 1
4 1% SLOPE 1% SLOPE

TO SWALE

BEGIN SLOPE
2'-0"
10'-0"

TO SWALE

BEGIN SLOPE
2'-0"

FINISH GRADE, SEE CIVIL DWGS
2'-0"MIN
16" W
SLOPE
2%

MAX OPERATION
WATER EL 620.00
SPRING
LINE
HPT
595.50
LPT 595.00
(SWALE LINE

ALL AROUND)
TOC 595.08
(ALL AROUND)
TOC 595.08

CONCRETE WALL

FOOTING AND SLAB

CONCRETE WALL

FOOTING AND SLAB

CONCRETE WALL

ASSEMBLY

ABC LEVELING COURSE

OVER COMPACTED EARTH

SUBGRADE COMPACTED
TO 95% OF MAXIMUM DRY
DENSITY PER ASTM D1557

ABC LEVELING COURSE OVER
COMPACTED EARTH SUBGRADECOMPACTED TO 95% OF MAXIMUM
DRY DENSITY PER ASTM D1557
10" OF SCARIFIED NATIVE MATERIAL
COMPACTED TO 95% RELATIVE COMPACTION

AND MOISTURE CONDITIONED

NATIVE SUBGRADE

CONCRETE WALL

ASSEMBLY

ANGLE POINT

PER OSHA

WHERE SHORING

IS USED (TYP)

SAFE CONSTRUCTIONSLOPE (TYP)

STRUCTURAL BACKFILL

UNLESS OTHERWISE

SPECIFIED COMPACT TO
95% RELATIVE

COMPACTION
(8) #6 CONTINUOUS

REINFORCMENT

CONCRETE WALL

FOOTING AND SLAB

EXTERIOR ALUMINUM

LADDER WITH
"SAF-T-CLIMB"

LADDER SYSTEM AND

CLIMBING DEVICE

OR EQUAL

ALUMINUMANTI-CLIMB DOOR

INTERIOR LADDER WITH
"SAF-T-CLIMB" DEVICE

PROVIDED REMOVABLE

TOP EXTENSION SECTION

ALUMINUM GUARDRAIL
4'x8' DOUBLE LEAF

ALUMINUM ACCESS HATCH
30-MIL MEMBRANE LINER
6-MIL POLYETHYLENE

SHEETING AT

CONTRACTOR OPTION
1 4
TYP
MP140
SAFE

CONSTRUCTION

SLOPE (TYP)

EXTEND CONCRETE

WALL FOOTING AS

REQUIRED

STRUCTURAL BACKFILL

UNLESS OTHERWISE

SPECIFIED COMPACT TO
95% RELATIVE COMPACTION

ENCASEMENT

REINFORCING STEEL
MUST BE INSTALLED 2"MINIMUM FROM ANY

PORTION OF PIPE

WATERSTOP

ANCHORED

FLEXIBLE-BASE

CONNECTION
6 99S08
5 99S08
SLOPE
2%
99S06

WATERSTOP (TYP)

FILTER FABRIC

WATERSTOP

ANCHORED

FLEXIBLE BASE

CONNECTION
JKN
NGB
KP
kjackson

Page 333 of 599 ends

(TYP)
1'-0"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
PURPOSES.

CONSTRUCTION

IS NOT TO BE USED FOR
2023, CA PE NO. 76832. IT
OF BRIAN W. AVON, APRIL

UNDER THE AUTHORITY

PURPOSE OF BIDDING

RELEASED FOR THE

THIS DOCUMENT IS
CHANGE DURING CONSTRUCTION.

DRAWINGS WILL BE PROVIDED AS A DESIGN
NOT FOR CONSTRUCTION. CONSTRUCTION
THIS DRAWING IS FOR BID PURPOSES ONLY.

PlotDate:4/5/202311:47:28AM
99S08
69 STRUCTURAL

STORAGE TANK

SECTION AND DETAILS
8660F1099S08.dwgkjackson 8660F10
TYP
MP080
TYP
MP310
3'-0"
4" FLG TEE W/ (2) 4"

BLIND FLANGES,
TAPPED 1 12" IPT, (2) 1
1 2" BRASS NIPPLES, (2)
1 12" HOSE VALVES W/

HANDWHEEL

OPERATOR AND CAP

AND CHAIN
TYPE 304 SST
BAFFLE 1/4" PLATE

NOTCH TO FIT

INSIDE PIPE
SCALE:FILE:
5 DETAIL
99S07 3/8" = 1'-0"
8660F1000S310

TANK INLET
SCALE:FILE:
6 DETAIL
99S07 3/8" = 1'-0"
8660F1000S310

TANK OUTLET
SCALE:FILE:

Y SECTION
99S08 3/8" = 1'-0"
8660F1000S310

TANK OVERFLOW
SCALE:FILE:
7 DETAIL
99S05 3/8" = 1'-0"
8660F1000S310

TANK WASHDOWN RISER
SCALE:FILE:
8 DETAIL - 3/4" = 1'-0"
8660F1000S310

ANTI-VORTEX

TOP OF INFLUENT
16" FLARE
TOC 595.08
3'-0" 10'-0" MIN
CL 591.00
FLOW
TYP
MP140
10'-0" MIN 3'-0"
TOC 595.08
FLOW
16" LR 90° ELBOW
CL 591.00

SPOOL PIECE

PIPE FLOORPENETRATION

FLUSH TO FLOOR
8- 16" RW
TYP
MP310
TYP
MP140
16" RW
TOP OF OVERFLOW 520.00
16" FLARE
6'-0"MAX
TYP
MP250
(TYP)
16" OF
CL 604.00
INV 597.00
TYP
CS202 36"x36" CATCH BASIN
3'-4"
16" DUCKBILL

CHECK VALVE
4" RW
CL 599.00
CL 591.00
TYP
MP140
16" RW
PLAN

SECTION
16" RW
TYPE 304 SST
BAFFLE 1/4" PLATE
16" OF

PIPE CONTINUATION
SEE DWG C01 FOR
SEE DWG 99C19 FOR

PIPE CONTINUATION
SEE DWG 99C19 FOR

PIPE CONTINUATION
JKN
NGB
KP

Page 334 of 599 ends

(TYP)
1'-0"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
PURPOSES.

CONSTRUCTION

IS NOT TO BE USED FOR
2023, CA PE NO. 76832. IT
OF BRIAN W. AVON, APRIL

UNDER THE AUTHORITY

PURPOSE OF BIDDING

RELEASED FOR THE

THIS DOCUMENT IS
CHANGE DURING CONSTRUCTION.

DRAWINGS WILL BE PROVIDED AS A DESIGN
NOT FOR CONSTRUCTION. CONSTRUCTION
THIS DRAWING IS FOR BID PURPOSES ONLY.

PlotDate:3/27/202311:14:25AM
GENERAL NOTES:

UTILITIES SHALL BE EXPOSED.

7. PRIOR TO DRILLING OF PIERS, ALL KNOWN
SECITON 03300.

6. FOR CONCRETE CLASS, SEE SPECIFICATION
ENGINEER.

REQUIREMENTS AND AS APPROVED BY THE
TIE IN ACCORDANCE WITH ACI 318

5. IF LAPS ARE REQUIRED FOR SPIRALS, LAP AND
80,000 PSI (ASTM615 GR 80).

4. PROVIDE SPIRALS WITH YIELD STRENGTH OF
TERMINATOR RATHER THAN STANDARD HOOK.

3. CONTRACTORS OPTION TO PROVIDE BAR END
A.H-20 LIVE LOAD
DESIGN LIVE LOADS:

2. BRIDGE STRUCTURAL DESIGN CRITERIA.

DRAWING 00S01.

1. FOR GENERAL STRUCTURAL NOTES, REFER TO
NGB
KP
99S09
70 STRUCTURAL
BRIDGE

PLAN AND SECTION
8660F1099S09.dwgkjackson 8660F10
A
8660F1001S120
3/8" = 1'-0"

NEW PREFAB RAILCAR

BRIDGE AND ANCHORAGEBY CONTRACTOR
EXIST
BRIDGE

FND (TYP)
1 99S02
B- 3/8" = 1' - 0"
8660F1001S320
(TYP)
9'-4"
(TYP)
3'-4"
(TYP)
3'-0"
(TYP)
6'-0"

B- (TYP
)
1'-0"
FIN GR 645.00
PROFESSIONAL ENGINEER.

SIGNED BY A CALIFORNIA REGISTERED

CALCULATIONS AND DETAILS STAMPED AND

TALL GUARD RAIL, SHOP DRAWINGS,
CONTRACTOR SHALL PROVIDE MINIMUM 3'-6"
REGISTERED PROFESSIONAL ENGINEER.

STAMPED AND SIGNED BY A CALIFORNIA

DRAWINGS, CALCULATIONS AND DETAILS

CONTRACTOR SHALL PROVIDE SHOP
TOPPING AND A CROSS SLOPE OF 2% MAXIMUM.

BRIDGE WITH 3" MINIMUM ASPHALT CONCRETE
PRE-MANUFACTURED 12' WIDE STEEL RAILCAR
CONTRACTOR TO VERIFY DIMENSION.

MINIMUM BEARING SEAT WIDTH = 20 INCHES.

C
99S02
2 10'-0"
10'-0"
1 99S02
2 (TYP)
3'-0"
12" PIPE PER CIVIL
DRAWING 99C14
90'-0"
(TYP MAX)
4'-0" D
99S02
(MAX)
1'-6"
(MAX)
1'-6"
4 3
5'-0" 1'-0"
4'-0"
TYP
MP100
TYP
P602
ELBOW FLxMJ
12" DI 90 DEG
FLxFL
4'-0" DI SPOOL
TYP
MP898
12" GV FLxFL
JOINT (BY OTHERS) FLxFL

BALANCED EXPANSION
12" FLEX TEND FORCE 1'-0" DI SPOOL FLxFL
1'-0" 5'-0"
4'-0"
TYP
P602
TYP
MP100
TYP
MP898
SPOOL FLxFL
4'-0" DI
ELBOW FLxMJ
12" DI 90 DEG JOINT (BY OTHERS) FLxFL

BALANCED EXPANSION
12" FLEX TEND FORCE
1'-0" DI SPOOL FLxFL
12" GV FLxFL
# KEY NOTES:

1. 2.

3. 4.

JKN

Page 335 of 599 ends

3"MINCLR
6"MIN
1" TYP
1"TYP
2"
2"
3"
4"MAX
3"MIN

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
PURPOSES.

CONSTRUCTION

IS NOT TO BE USED FOR
2023, CA PE NO. 76832. IT
OF BRIAN W. AVON, APRIL

UNDER THE AUTHORITY

PURPOSE OF BIDDING

RELEASED FOR THE

THIS DOCUMENT IS
CHANGE DURING CONSTRUCTION.

DRAWINGS WILL BE PROVIDED AS A DESIGN
NOT FOR CONSTRUCTION. CONSTRUCTION
THIS DRAWING IS FOR BID PURPOSES ONLY.

PlotDate:3/24/20233:28:56PM
GENERAL NOTES:

BEND INTO THE CONCRETE CORE AT ENDS.
(2) EXTRA TURNS AND A 135 DEGREE HOOK

ENSURE THAT THE SPIRAL IS TERMINATED WITH

LENGTH ON SITE PER NEW PIER LENGTHS,

8. FOR REBAR CAGES THAT ARE REDUCED IN
2460.

LOAD TESTING PER SPECIFICATION SECTION
ADDITIONAL INFORMATION. CONDUCT PIER
SPECIFICATION SECTIONS 2467A AND 2466B FOR
PRESSURE-GROUTED PILES. SEE

HOLE CONCRETE PILES OR AUGURED

7. ALL PILES SHALL BE CAST-IN-PLACE DRILLED
UTILITIES SHALL BE EXPOSED.

6. PRIOR TO DRILLING OF PIERS, ALL KNOWN
SECTION 03300.

5. FOR CONCRETE CLASS, SEE SPECIFICATION
ENGINEER.

REQUIREMENTS AND AS APPROVED BY THE
TIE IN ACCORDANCE WITH ACI 318

4. IF LAPS ARE REQUIRED FOR SPIRALS, LAP AND
80,000 PSI (ASTM615 GR 80)

3. PROVIDE SPIRALS WITH YIELD STRENGTH OF
TERMINATOR RATHER THAN STANDARD HOOK.

2. CONTRACTORS OPTION TO PROVIDE BAR END
DRAWING 00S01.

1. FOR GENERAL STRUCTURAL NOTES, REFER TO
JKN
NGB
KP
99S10
71 STRUCTURAL
BRIDGE

SECTIONS AND DETAILS
8660F1099S10.dwgkjackson 8660F10
C
S01 3/4" = 1' - 0"
8660F1001S320
E- 3/4" = 1' - 0"
8660F1001S320
3'-0"

TIES SEE SCHEDULE

PIER SCHEDULE ON THIS SHEET

FOR REINFORCEMENT SEE DRILLED
EXTEND SPIRALS 12 INCHES INTO PIER CAP.

CONNECTION OF W8X.

REQUIRED FOR FULL BEARING AND
SIDES WITH A 1/4" THICK FILLET WELD IF
WELDED TO BRIDGE BEAM AND W8X ON ALL
PROVIDE 3/8" THICK OVERSIZED STEEL PLATE
(TYP).

HOLES TO ALLOW LONGITUDINAL MOVEMENT
PER MANUFACTURER. PROVIDE SLOTTED
BRIDGE BEARING PLATE AND ANCHOR BOLTS LONGITUDINAL BAR.

AROUND THE PERIMETER ENCLOSING THE

CIRCULAR TIES SHALL BE STAGGERED
MINIMUM OVERLAP. ENDS OF ADJACENT
ENGAGE A LONGITUDINAL BAR WITH 6"

DEGREE MINIMUM STANDARD HOOKS AND
TIES ENDS SHALL TERMINATE WITH 135
1 #5@8" EW EF (TYP)

DRILLED PIER SCHEDULE
LABEL
(FT)

DIAMETER
(FT)

PIER LENGTH

REINFORCEMENT

VERTICAL

TIES OR SPIRAL
P1 3'-0" 45'-0" (16) #10 (2) #5@6"

BUNDLED SPIRAL
1- 3/4" = 1' - 0"
8660F1001S320
E- PREFAB RAIL CAR BRIDGE AND ANCHORAGE BY CONTRACTOR (8) #6@8" T&B (TYP) 2 FIN GR 645.00 FIN GR 637.00
EL 635.00EL 632.17
EL 635.00EL 632.17
PIER P1 (TYP)
PIER P1 (TYP)
D
S01 3/4" = 1' - 0"
8660F1001S320
W8x18
L3x3x3/8
W8x18

PREFAB RAIL CAR

BY CONTRACTOR
1" NEOPRENE PAD

PIPE STRAP
12" PIPE PER CIVIL
DRAWING 99C14
3/8" GUSSET

CUT TO FIT
(TYP)
3/4" DIA A325-N BOLTS

IN STD HOLE (TYP)
2'-3" MAX
1/4"
1/4"
1/4"
#6@8" T&B
#6@8" T&B
#6@8" T&B

CONTRACTOR TO MATCH
EXISTING GRADE. REPLACEEXISTING PATH TO MATCH

BRIDGE ELEVATION (TYP)
3 # KEY NOTES:

1. 2.

3. 4
1/4"
TYP

4.

Page 336 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:34
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
00M01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:8660F1000M01.dgn

MECHANICAL
8660F10
CE
CE
V
V
K

SILENT CHECK VALVE

ECCENTRIC PLUG VALVE

MUD VALVE (PLAN VIEW)
ELBOW, 11.25 DEGREE
ELBOW, 22.5 DEGREE

SWING CHECK VALVE

FLEXIBLE COUPLING ADAPTER

DISMANTLING JOINT

WAFER CHECK VALVE

GLOBE VALVE
ANCHOR
CAP
CROSS

LATERAL
TEE
UNION

FLANGED COUPLING ADAPTER

GROOVED END ADAPTER

FLANGED COUPLING ADAPTER

FLEXIBLE COUPLING

EXPANSION COMPENSATOR
ELBOW, 90 DEGREE

LUBRICATED PLUG

BALL CHECK VALVE

KNIFE GATE VALVE

MIXING VALVE

DUAL CHECK VALVE

DIAPHRAGM VALVE
FLANGE
ELBOW, 45 DEGREE

EXP JOINT

PINCH VALVE

PLUG VALVE
(RUBBER GASKET)

FLANGED JOINT

ADAPTER SIDE

THRUST TIES

WITH THRUST TIES

WELDED JOINT

CONTROL VALVE

GATE VALVE

BALL VALVE

CHARACTERIZED BALL

BUTTERFLY VALVE

TEE DOWN

METAL BELLOWS EXP JOINT

FLEXIBLE COUPLING WITH

ELASTOMER BELLOWS

HUB & SPIGOT JOINT

GROOVED END JOINT

CONCENTRIC REDUCER

ELBOW DOWN

ELBOW UP
TEE UP

LATERAL DOWN

LATERAL UP
VALVE
(RESTRAINED)

PUSH-ON JOINT
3-WAY GLOBE TYPE

NEEDLE VALVE

PREVENTER

CHECK BACKFLOW
M
S
X
M
PUMP: ROTARY
PUMP: METERING
CAVITY
PUMP: CENTRIFUGAL
PUMP: PLUNGER

VENTURI TUBE
STRAINER: WYE TYPE
STRAINER: WYE TYPE

WITH BLOWOFF
WEIR

SLUICE GATE
PUMP: DIAPHRAGM
VALVE: TELESCOPING
VALVE: PLUG ECCENTRIC
VALVE: SWING CHECK
VALVE: AIR RELIEF
VALVE: ANGLE

PRESSURE-REDUCING REGULATOR

PULSATION DAMPENER
PRIMARY FLOW ELEMENT:

PUMP: RECIPROCATING
PUMP: PROGRESSIVE
X = U - ULTRASONIC
X = TH - THERMAL
X = R - ROTAMETER
X = M - MAGNETIC
X = C - CORIOLIS
PRIMARY FLOW ELEMENT:

PUMP: SUBMERSIBLE
PUMP: SCREW
FLUME
PRIMARY FLOW ELEMENT:

ORIFICE PLATE
X = PT - PITOT TUBE

ROTARY CHEMICAL

RUPTURE DISK

SLIDE GATE

SAMPLE PORT

SIGHT GLASS
FEEDER
PRIMARY FLOW ELEMENT:

X = T - TURBINE
X = P - PROPELLER
PRIMARY FLOW ELEMENT:

X = D - DENSITY
VALVE: CONE
VALVE: GATE

FLOW SWITCH

FIRE HYDRANT
RADAR
PRIMARY LEVEL ELEMENT:

THERMOMETER

W/ EXTERNAL PRESSURE TAP

REGULATOR W/EXTERNAL

BACKPRESSURE REGULATOR
VALVE: THREE WAY

BACKPRESSURE REGULATOR
PUMP: PERISTALTIC TUBE METERING
VALVE: THREE WAY
VALVE: THREE WAY

MOTOR OPERATED

SELF-CONTAINED

AIR OPERATED

SOLENOID OPERATED
VALVE: BUTTERFLY
VALVE: BALL CHECK
VALVE: BALL
VALVE: PLUG CONCENTRIC
VALVE: PRESSURE RELIEF
VALVE: VACUUM

PRESSURE TAP

PRESSURE-REDUCING

PRESSURE-REDUCING
VALVE: PINCH
VALVE: NEEDLE
REGULATOR: SELF-CONTAINED
VALVE: FLAPPER CHECK
VALVE: DIAPHRAGM
VALVE: FOUR WAY
VALVE: GLOBE
VALVE: HOSE

DIFFUSER

AIR VENT

OR FLUSHING

RECIPROCATING
DRAIN
BLOWER

QUICK DISCONNECT
PRIMARY LEVEL ELEMENT:

HIGH PRESSURE AIR

BATCHMETER

AIR OR CHEMICAL
COMPRESSOR:

ELECTRIC MOTOR

EXPANSION JOINT,

EQUIPMENT DRAIN
PUMP: VERTICAL LIFT
PIPE REDUCER: CONCENTRIC

FLEXIBLE VIBRATION

COMPRESSOR/TURBINE

CALIBRATION COLUMN

DIAPHRAGM SEAL
JOINT

EJECTOR OR EDUCTOR

FLAME ARRESTER

FLOOR DRAIN

FLAME ARRESTER WITH

PRESSURE

THERMALLY OPERATED VALVE
FAN: EXHAUST/SUPPLY
FILTER
WEIR

FLOAT SWITCH

ULTRASONIC
PRIMARY LEVEL ELEMENT:

PRIMARY LEVEL ELEMENT:

OIL OR MOISTURE TRAP
GAUGE: PRESSURE
GAUGE: DIFFERENTIAL
MIXER
PRIMARY LEVEL ELEMENT:

BUBBLER

BASKET STRAINER
PRIMARY LEVEL ELEMENT:

ELECTRODE
PRIMARY LEVEL ELEMENT:

FLUID

DOUBLE LINE SINGLE LINE DESCRIPTION DOUBLE LINE SINGLE LINE DESCRIPTION SINGLE LINE DESCRIPTION SINGLE LINE DESCRIPTION SINGLE LINE DESCRIPTION

PROCESS LINE SYMBOLS

LINE SYMBOLS
CONTINUATION TO DWG NO.

CONTINUATION FROM DWG NO.

UNIQUE IDENTIFIER

CHEMICAL INJECTION POINT

CONTINUATION TAG

PIPE ABOVE OR BELOW GROUND
DEMO

EXISTING
FUTURE

OR STRUCTURE

PIPE UNDERNEATH SLAB

PRIMARY PROCESS FLOW IN CHANNEL

SECONDARY PROCESS FLOW IN CHANNEL

PRIMARY PROCESS FLOW IN PIPE

SECONDARY PROCESS FLOW IN PIPE

PIPE DESIGNATOR

EQUIPMENT / VALVE TAG

PIPE SIZE FLOW STREAM

PIPE MATERIAL CHANGE
M

XXX-XX-XXXX
X" XXX
C
B
A
DWG NO.

CHEMICAL
(FOT. FOB)

ECCENTRIC REDUCER
(FOT, FOB)
PIPE REDUCER: ECCENTRIC
VALVE: THREE WAY

PIPING SYMBOLS MECHANICAL SYMBOLS IDENTIFICATION SYMBOLS

INVERTED COLUMN
eparker

GENERAL MECHANICAL SYMBOLS
JD
72 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:56:50-04'00'

Page 337 of 599 ends

XX" INSULATION (INSIDE) XX" INSULATION (OUTSIDE)

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405

HUMIDISTAT
THERMOSTAT 60" ABOVE FINISH FLOOR

ROOF VENT OR ROOF FAN

UNIT HEATER (HORIZONTAL TYPE)

INLINE/AXIAL FAN

ROOF/SIDEWALL FAN

CENTRIFUGAL FAN

DIRECT EXPANSION COIL

COOLING COIL

CONTROL PANEL

SOLENOID VALVE

GAS HEATER

ELECTRIC HEATER
FILTER

MOTOR OPERATED VALVE

UNIT HEATER (VERTICAL TYPE)

TURNING VANES

FLEXIBLE DUCT

ACCESS DOOR

FLEXIBLE CONNECTION

SIDE MOUNT DEVICE

ROUND DUCT

DIRECTION OF FLOW

TO SPACE

FROM SPACE
20x12 16 DIA
20x12 16x8
AD
AD
R
20x12
20x12
12x20

MOTORIZED

BACKDRAFT

BALANCING
APPEAR ON THE CONTRACT DRAWINGS.

ABBREVIATIONS. NOT ALL ITEMS SHOWN HERE
NOTE:THIS IS A GENERAL LIST OF SYMBOLS AND
OR
FD

DAMPERS

SUPPLY RETURN EXHAUST
M
M

FIRE W/ ACCESS DOOR

DUCT SMOKE DETECTOR

9. PROVIDE TURNING VANES IN ALL ELBOWS. (SHOWN OR NOT)

8. COORDINATE FINAL LOUVER SIZE AND LOCATION WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.

OUT AT ALL LOCATIONS WHERE THEY APPLY.

7. TYPICAL DETAILS SHALL BE USED FOR ALL PERMANENT WORK EVEN THOUGH THEY ARE NOT CALLED

6. THIS IS A GENERAL LIST OF SYMBOLS. NOT ALL ITEMS SHOWN HERE APPEAR ON CONTRACT DRAWINGS.

FURNISHED AND INSTALLED BY THE CONTRACTOR AS SPECIFIED.

OTHERWISE DETAILED ON THE DRAWINGS ALL PIPE AND DUCT SUPPORTS SHALL BE DESIGNED,

5. NOT ALL AND ONLY CERTAIN TYPES OF SUPPORTS ARE SHOWN ON THE HVAC DRAWINGS. UNLESS AS SHOWN ON THE TYPICAL DETAILS.

4. UNLESS OTHERWISE SHOWN ON THE DRAWINGS ALL FLOOR SLAB AND WALL PENETRATIONS SHALL BE HVAC SYSTEMS TO PROVIDE THE COMPLETE SYSTEM.

NOT EVERY FITTING AND OFFSET IS SHOWN. THE CONTRACTOR SHALL FURNISH, INSTALL AND TEST ALL ETC. REQUIRED FOR THE COMPLETE SYSTEM. SMALL PIPING IS SHOWN APPROXIMATELY TO SCALE BUT

3. HVAC PIPING AND DUCTWORK DRAWINGS DO NOT SHOW ALL DRAINS, VENTS, OFFSETS AND FITTINGS PIPE TO OTHER TYPES OF METALLIC PIPING.

2. DIELECTRIC COUPLINGS, FLANGES OR UNIONS SHALL BE INSTALLED AT ALL CONNECTIONS OF COPPER STRUCTURAL DRAWINGS.

EQUIPMENT SHALL BE SET ON CONCRETE PADS CONFORMING TO DETAILS SHOWN ON THE TYPICAL SHALL BE DETERMINED BY THE CONTRACTOR FOR THE EQUIPMENT FURNISHED. ALL FLOOR MOUNTED

1. SIZES OF EQUIPMENT PADS INDICATED ON THE DRAWINGS ARE APPROXIMATE. EXACT DIMENSIONS

FIRST NUMBER IS TOP

DUCT SECTION, NEGATIVE PRESS

FIRST NUMBER IS TOP

DUCT SECTION, POSITIVE PRESS

RISE, (D) DROP

ELEVATION CHANGE (R)

IS SIDE SHOWN

DUCT SIZE- FIRST NUMBER

COMPRESSOR

A/C OR HEAT PUMP

TRANSFER GRILLE

ARROWS INDICATE FLOW DIRECTION

SUPPLY DIFFUSER OR GRILLE

ARROWS INDICATE FLOW DIRECTION

RETURN DIFFUSER OR GRILLE

ARROWS INDICATE FLOW DIRECTION

EXHAUST DIFFUSER OR GRILLE

OR DUCT TAKEOFF

REGISTER, GRILLE, DIFFUSER

BOTTOM MOUNT DEVICE

TRANSITION

RECTANGULAR

RECTANGULAR TO

ROUND TRANSITION

RECTANGULAR TO

PRESSURE)

DIAGONAL FOR NEGATIVE

ELBOW TURNED UP (USE ONE

POSITIVE PRESSURE DUCT -

PRESSURE)

DIAGONAL FOR NEGATIVE

ELBOW TURNED DOWN (USE ONE

POSITIVE PRESSURE DUCT -

INSTALLATION

CONFIRM ORIENTATION OF

SMOKE DETECTOR

INSTALLATION

CONFIRM ORIENTATION OF
SMOKE

INSTALLATION

CONFIRM ORIENTATION OF

COMBINATION SMOKE AND FIRE
T
S
M
H

TYPE OF REGISTER
SIDEWALL-ADJUSTABLE;
CFM FLOW PATTERN;

BOOT (IF REQ'D)

NECK SIZE

C-CORNER
(AS DESCRIBED IN

OR GRILLE
400/4
SR-1(B)/12x12

SPECIFICATIONS)

LEGEND FOR REGISTERS & GRILLES

PRESSURE DIFFERENTIAL SWITCH
PD

AIR FLOW SWITCH AFS
C
C
D
X

DUCT UP THRU ROOF OR FLOOR

ABBREVIATIONS

BDD BACKDRAFT DAMPER

BOD BOTTOM OF DUCT

AFF ABOVE FINISHED FLOOR

BD BALANCING DAMPER
AT
CH

DG DOOR GRILLE

EA EXHAUST AIR

FA FOUL AIR
MD

RA RETURN AIR

RR RETURN REGISTER OR GRILLE

SA SUPPLY AIR
SD
SFD
SR

SMOKE DAMPER OR SMOKE DETECTOR

SMOKE & FIRE DAMPER COMBINATION

SUPPLY REGISTER, GRILLE OR DIFFUSER

AFS AIR FLOW SWITCH

AHU AIR HANDLING UNIT

BLR BOILER

EF EXHAUST FAN

EUH ELECTRIC UNIT HEATER
NC
NO

NORMALLY CLOSED

NORMALLY OPEN

MAU MAKEUP AIR UNIT

MOTORIZED DAMPER

OA OUTSIDE AIR

PPU POSITIVE PRESSURIZATION UNIT

WUH WATER UNIT HEATER

AC AIR CONDITIONING

CO CARBON MONOXIDE DETECTOR

CHILLER
CT
CS
CU

COOLING TOWER

CURRENT SENSOR

CONDENSING UNIT

DP DIFFERENTIAL PRESSURE

ECU EVAPORATIVE COOLING UNIT

FD FIRE DAMPER

FCU FAN COIL UNIT

GUH GAS UNIT HEATER

HP HEAT PUMP

OCF ODOR CONTROL FAN

SF SUPPLY FAN

VAV VARIABLE AIR VOLUME

LOUVER/BRICK VENT - OPERABLE

LOUVER/BRICK VENT - FIXED

DUCT DOWN

DUCT UP

CURRENT SENSOR CS

SIZE VARIES
(INSIDE) OR (OUTSIDE)

DUCT INSULATION
@
D
A
B
C
E
F
M
P
R
S
N
O
W
G
H
V

NOTES DUCTWORK SYMBOLS EQUIPMENT SYMBOLS REGISTERS, GRILLES & LOUVERS SYMBOLS

FEATURE SYMBOL FEATURE SYMBOL FEATURE SYMBOL
CE
CE
JD
00M02
73 MECHANICAL

GENERAL HVAC NOTES, ABBREVIATIONS,

AND SYMBOLS
8660F1000M02.dw
g 8660F10
P
lotD
ate:2/20/2023
3:24:43
PM
eparker
Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:56:55-04'00'

Page 338 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:11
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
60M01
eparker
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

AL

MECHANICAL

PLANS AND SECTION
8660F10 8660F1060M01.dgn
#
GENERAL NOTES:

KEY NOTES:

A
B
- 1/4" = 1'-0"
1/4" = 1'-0"
8660F1060M9101
8660F1060M9301
B
-
EX-24" FE
EX-24" FE
24" BFV
EX-12" FE

DRAIN RISER
EX-42" FE

FACILITY

CHLORINATION
FROM
EX-24" FE
EX-42" FE
EX-42" FE
EX-24" FE
EYY

DECHLORINATION STRUCTURE
M
M

STRCTURE

DECHLORINATION
24" BFV
24" BFV
EX-2" SO2
1 2
1 2
# KEY TAGS:

1. FCV-60100 DCL STRUCTURE VALVE 1
AE-60101

2. FCV-60102 DCL STRUCTURE VALVE 2

3. C
-
3 C

NOT TO SCALE

PUMP STATION

CAROUSEL
TO
2 RIVER

RUSSIAN
TO
2 3
9 CHLORINE ANALYZER 4
PUMP 5
SAMPLE
FROM
PUMP 4
SAMPLE
FROM
5 6
8 7

SCHEMATIC
8660F1060M9101
(STP)

CONTACT BASINS

CHLORINE
FROM
(STP)
(STP)
4 (STP)
INV 564.5±

3. SEE CIVIL DRAWINGS FOR YARD PIPING CONTINUATION.

AND ORIENTATION OF VALVES AND VALVE ACTUATORS.

2. CONTRACTOR SHALL COORDINATE WITH THE CITY, THE LOCATION, BOLTS, AND GASKETS.

EXISTING PIPING COMPONENTS. DO NOT REUSE THE OLD NUTS,

FOR ALL CONNECTIONS, INCLUDING REINSTALLATION OF ANY

1. CONTRACTOR SHALL PROVIDE NEW NUTS, BOLTS, AND GASKETS MATCHES THE EXISTING CONFIGURATION.

9. CONTRACTOR SHALL PROVIDE A DRAIN CONFIGURATION THAT

8. TIE INTO EXISTING THREE-WAY VALVE.

DIMENSIONS.

7. EXISTING CONCRETE PAD. CONTRACTOR TO FIELD VERIFY
AUTOMATED ACTUATION VALVE.

CHLORINATED SAMPLES. PUMP SENDS FLOW TO A THREE-WAY

6. SAMPLE PUMP 4 IS A ROTARY PUMP THAT IS USED FOR
AUTOMATED ACTUATION VALVE.

DECHLORINATED SAMPLES. PUMP SENDS FLOW TO A THREE-WAY

5. SAMPLE PUMP 5 IS A SUBMERSIBLE PUMP THAT IS USED FOR INFORMATION.

AND INSTRUMENTATION (60N01) DRAWINGS FOR ADDITIONAL
EXISTING ENCLOSURE IN PLACE. REFER TO ELECTRICAL (60E01) 17505. THE EXISTING ENCLOSURE IS TO REMAIN IN USE. PROTECT

4. REPLACE CHLORINE ANALYZER 4 PER SPECIFICATION SECTION STRUCTURE. CONTRACTOR TO FIELD VERIFY AREA.

3. AREA IS A DIAGRAMMATIC VIEW OF PAD EAST OF DECHLORINATION AND SPECIFICATION SECTION 13447.

2. VALVE IS 20 +/- FT DEEP. REFER TO SPECIFICATION SECTION 15112

1. EXISTING VALVE ABANDONED IN PLACE.

CONC VAULT

EXISTING PRECAST
JD
74 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:00-04'00'

Page 339 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
M M
M
M M M
P
lotD
ate: 06-APR
-2023 1:27:41
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85M01
eparker
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

EYY
AL

MECHANICAL
8660F10 8660F1085M01.dgn

AWT PUMPS

CLARIFIER FILTER UNITS
MIX
RAPID

BACKWASH PUMPS

AIR WASH BLOWERS

FACILITY

CHLORINATION
FROM
SH SH
SAM
SAM
CLS

RECOVERY BASINS

TO WASHWATER

CONTACT BASINS

TO CHLORINE
C
C
C
C
SH
COAG
POLY
POLY
AA
CC
I
AAFEB
W
W WCC
I
AA
BW
WW
FE
FLR
FLR
FLR
FLR
LEGEND:

SAM
SAM

WW - WASHWATER

SH - SODIUM HYDROXIDE

SAM - SAMPLE

POLY - POLYMER

FLR - FILTER

FE - FINAL EFFLUENT

COAG - COAGULANT

CLS - CHLORINE SOLUTION
CCl - CHLORINE LIQUID

C - CLARIFIER

BW - BACKWASH

AA - AERATION AIR/AIR WASH
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M

AWT PROCESS FLOW SCHEMATIC
M
M
M
M
JD
75 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:05-04'00'

Page 340 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:08
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85M02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

EYY
ELP

MECHANICAL
8660F10 8660F1085M02.dgn
C
85M03
E
85M04
G
85M05
B
85M03
A 3/16"=1'-0"
EX-2" FC
8" AA
EX-24" WW
EX-1" POLY
EX-6" AA
EX-6" AA EX-6" AA
CLARIFIER NO.4 CLARIFIER NO.3 CLARIFIER NO.2 CLARIFIER NO.1 FILTER NO.4 FILTER NO.3 FILTER NO.2 FILTER NO.1
EX-12" FE EX-18" FE EX-14" BW
X KEY TAGS:

EX-24" FE
8660F1085M0101

M M M M

STORAGE TANK

FERRIC CHLORIDE

RAPID MIX DIFFUSER ASSEMBLY
12" BFV (TYP)
14" BFV (TYP)
12" BFV (TYP)
M M
M
M
M
M
M M
13 14 10 5
1 1 16
1 15 12 11

1. FCV-85211 INFLUENT VALVE NO.1

2. FV-85212 AIR VALVE NO.1

3. FV-85217 BACKWASH VALVE NO.1

5. FCV-85221 INFLUENT VALVE NO.2

6. FV-85222 AIR VALVE NO.2

7. FCV-85228 EFFLUENT VALVE NO.2

8. FV-85227 BACKWASH VALVE NO.2

9. FCV-85231 INFLUENT VALVE NO.3

10. FV-85232 AIR VALVE NO.3

12. FCV-85238 EFFLUENT VALVE NO.3

13. FCV-85241 INFLUENT VALVE NO.4

14. FV-85242 AIR VALVE NO.4

16. FCV-85248 EFFLUENT VALVE NO.4

15. FV-85247 BACKWASH VALVE NO.4

17. LCP-85106 AIR WASH BLOWER NO. 1

18. LCP-85107 AIR WASH BLOWER NO. 2

19. LCP-85108 AIR WASH BLOWER NO. 3

20. PMP-85181 COAGULANT FEED PUMP NO. 1

21. PMP-85182 COAGULANT FEED PUMP NO. 2

22. PMP-85183 COAGULANT FEED PUMP NO. 3
9 6
22 21
8 7 4 3
2 2 2 2
3 3 3 3 5

4. FCV-85218 EFFLUENT VALVE NO.1

11. FV-85237 BACKWASH VALVE NO.3

23. #
GENERAL NOTES:

KEY NOTES:
1 6" BFV (TYP) 2 1
8" AA
23 4
8" AA
FCV-25214 WEST GATE VALVE NO.1

FEED PUMPS

EXISTING CAUSTIC
EX-4" SW 6

AWT CLARIFIER/FILTER PLAN
20 8
9 ANODE (TYP)

MAGNESUIM
(TYP OF 4)

WASTE GATE
TANK

CAUSTIC STORAGE
(STP) (STP) (STP) (STP)
(PVC)
EX-12" FE
(STP)
(SST) (SST)
EX-12" FE
(STP)
(SST)
EX-12" FE
(STP)
EX-24" FE
7 1
85M04
19 17
2 1/2" FC
3" FE
(STP)
D
85M04
F
85M05
24 M M M M

24. PMP-85104 RAPID MIX PUMP
18 12 25
8" AA
11 10

TROUGH (TYP)

COLLECTION

25. FE-85105 AIR WASH VENTURI FLOW METER
eparker
11 12. REINSTALL EXISTING VENTURI FLOW METER.

11. PENETRATE WALL AS REQUIRED FOR NEW 8-INCH AIR PIPING.

REMOVED. REFER TO 85D01 AND SPECIFICATION SECTION 01140.

10. BLIND FLANGE TEE ONCE EXISTING 6-INCH PIPING HAS BEEN SECTION 11242.

9. PROVIDE A RAPID MIX PUMP PER SPECIFICATION SPECIFICATION REFER TO PHOTO 4/85D03 FOR THE PUMP THAT WILL BE REPLACED.

8. PROVIDE A COAGULANT PUMP PER SEPCIFICATION SECTION 11242.

REFER TO PHOTO 6/85D03 FOR THE TIE-IN LOCATION.

7. PROVIDE A TEE TO TIE INTO THE EXISTING AERATION AIR LINE.

6. ABANDON LINE IN PLACE. REFER TO 85D01 AND 85D02.

PROCESS.

SPECIFICATION SECTION 09960 DURING THE MEDIA REPLACEMENT

5. CONTRACTOR TO FULLY RECOAT THE CLARIFIER/FILTER TANKS PER PHOTO 6/85D03. OTHER WASTE GATES NOT SHOWN FOR CLARITY.

AWT CLARIFIER/FILTER UNIT WITH A LINEAR ACTUATOR. REFER TO

4. REPLACE EXISTING PNEUMATIC WASTE GATE ACTUATOR ON EACH

3. REPLACE ADSORPTION CLARIFIER MEDIA.

2. REPLACE FILTER MEDIA AND FILTER GRAVEL SUPPORT.

AND ACTUATORS PER SPECIFICATION SECTION 13447.

1. PROVIDE BUTTERFLY VALVE PER SPECIFICATION SECTION 15112 JD
76 AWT CLARIFIER/FILTER UNITS.

5. REFER TO SPECIFICATION SECTION 11802 FOR WORK ON THE FOUR

4. SEE CIVIL DRAWINGS FOR YARD PIPING CONTINUATION.

AND ORIENTATION OF VALVES AND VALVE ACTUATORS.

3. CONTRACTOR SHALL COORDINATE WITH THE CITY THE LOCATION BOLTS, AND GASKETS.

EXISTING PIPING COMPONENTS. DO NOT REUSE THE OLD NUTS,

FOR ALL CONNECTIONS, INCLUDING REINSTALLATION OF ANY

2. CONTRACTOR SHALL PROVIDE NEW NUTS, BOLTS, AND GASKESTS CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS.

1. BACKGROUND IS BASED ON THE 1994 RECORD DRAWINGS.

Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:11-04'00'

Page 341 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:54
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85M03
eparker
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

EYY
ELP

MECHANICAL

PLAN AND SECTIONS
8660F10 8660F1085M03.dgn
B
85M02 1/4"=1'-0"
C
85M02 1/4"=1'-0"

M M M M

M M M M
#
GENERAL NOTES:

KEY NOTES:
8660F1085M0300
8660F1085M0302
EX-24" CCI
EX-6" AA
EX-24" CCI
EX-12" CCI
EX-12" CCI
EX-6" AA EX-6" AA EX-6" AA
EX-20" WW EX-18" CCI
EX-18" CCI
EX-20" WW
EX-20" WW
12" BFV (TYP)
6" BFV (TYP)
EX-12" FE
EX-14" BW
EX-12" FE
EX-14" BW
EX-4" SW
EX-14" BW
EX-18" FE
EX-24" FE
EX-4" SW
EX-14" BW EX-24" FE EX-12" FE EX-14" BW
EX-12" FE
EX-14" BW
EX-12" FE
EX-14" BW
M M
M M
M M

M M M M
1 3
2 4
EX-1" VENT EX-1" VENT EX-1" VENT
EX-1" VENT
8" AA
EX-6" AA
(TYP) 1

1. REFER TO GENERAL NOTES ON 85M02.

1. FV-85219 AC AIR SCOUR VALVE NO. 1

2. FV-85229 AC AIR SCOUR VALVE NO. 2

3. FV-85239 AC AIR SCOUR VALVE NO. 3

4. FV-85249 AC AIR SCOUR VALVE NO. 4
X KEY TAGS:
(SST)
(STP) (STP)
(SST)
(STP)
(SST)
(SST)
(STP)
(STP)
(STP)
(STP)
(STP)
(STP)
(STP) (STP)
(STP)
(STP)
(STP)
(STP)
(STP) (STP) (STP)
(STP)
(SST)
(STP) (STP)
(STP)
(STP)
(STP)

AWT CLARIFIER/FILTER
TYP
2 MP272

STANDPIPE
EXISTING 42"
(TYP)
REFER TO SECTION 09960.

2. RESTORE TANK COATINGS AFTER INSTALLING PIPE SUPPORTS.

BE DETERMINED.

SCOUR LINE AS DIRECTED BY THE MANUFACTURER. LOCATION TO

1. PROVIDE NEW PENETRATION IN EXISTING AWT UNITS FOR NEW AIR JD
77 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:16-04'00'

Page 342 of 599 ends

BLOWER NO.1

AIR WASH
BLOWER NO.3

AIR WASH

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:06
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85M04
eparker
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

EYY
ELP

MECHANICAL
8660F10 8660F1085M04.dgn
D
85M02 3/8"=1'-0"
E
85M02 3/8"=1'-0"
8" AA
8660F1085M0301 8660F1085M0303
TYP
MP132
1 SECTIONS

AIR WASH BLOWERS
8" AA
4" AA
NO.2
BLOWER

AIR WASH
NO.3
BLOWER

AIR WASH

1. REFER TO GENERAL NOTES ON 85M02.
#

1. PROVIDE OVERHEAD PIPE SUPPORTS FIVE FEET ON CENTER.

GENERAL NOTES:

KEY NOTES:
4" AA 4" AA 4" AA
JD
78 FLOW METER
Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:21-04'00'

Page 343 of 599 ends

RAPID MIXER
PUMP NO.1

COAGULANT FEED
PUMP NO.2

COAGULANT FEED
PUMP NO.3

COAGULANT FEED
9"
1'-0"
3'-6"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:27:12
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85M05
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

EYY
ELP

MECHANICAL
8660F10 8660F1085M05.dgn
G
85M02 3/8"=1'-0"
8660F1085M0301
1 RAPID MIX DIFFUSER ASSEMBLY
NTS
8660F1085M0305
85M02

COAGULANT FEED PUMP AND RAPID MIX PUMP
F
85M02 1/4"=1'-0"
8660F1085M0101
TANK

CAUSTIC STORAGE

STORAGE TANK

FERRIC CHLORIDE
EX-2" FC

RAPID MIX DIFFUSER ASSEMBLY
1 85M05
2 1/2" FC
3" FE
G
85M05
EX-1" POLY

FEED PUMPS

EXISTING CAUSTIC
GENERAL NOTES:

RAPID MIX PUMP

PLAN, SECTION, AND DETAIL

1. REFER TO GENERAL NOTES ON 85M02.

CL PIPE
FLOW
(M
IN
)

WALL THICKNESS

CUT AWAY DEPICTS PIPE

DISCHARGE PIPE

FLASH MIX PUMP
3" FE

SIZE, AND MATERIAL

SEE DWGS FOR TYPE,

CHEMICAL SUPPLY LINE,

PIPING MATERIAL LIST
1 2
4 5
3 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
UNION
6" STEEL FLANGE, 150 LB, FLAT FACE, AWWA
LENGTH AS REQD, 2" TITANIUM PIPE

THREADED
1" TITANIUM WELDED OUTLET BRANCH CONNECTION,
1/2" X 1" TITANIUM NIPPLE, THREAD X BUTT

WELD TO INSIDE WALL OF PIPE
1/4" THICK X ID TITANIUM PLUG, FABRICATED AND
6" 316 STN STL, BLIND FLANGE. 150 LB, AWWA
FLANGE
2 1/2" 316 STN STL ALIGNING SOCKET , WELD TO BLIND
3" 316 STN STL, 150 LB FLANGE, FLAT FACE, AWWA
6" 316 STN STL, 150 LB BLIND FLANGE
3" STL, 150 LB FLANGE, FLAT FACE, AWWA
LENGTH AS REQD, 316 STN STL, SCHED 40
SHORT RADIUS ELBOW, 316 STN STL, SCHED 40
INTO SOCKET.

WRAPPED AROUND PIPE/TUBE PRIOR TO INSERTION
1/4" THICK FOOD GRADE, BUNA RUBBER STRIP
1 1/2" SCH 40, 316 STN STL. WELD TO ELBOW

TO BLIND FLANGE
1 1/2" THREADED HALF COUPLING, 316 STN STL, WELD
3" X 2 1/2" REDUCER, 316 STN STL, SCH 40
1 1/2" GROOVED COUPLING, 316 STN STL
3" 316 STN STL BLIND FLANGE, 150 LB, AWWA
6" STL, 150 LB FLANGE, FLAT FACE, AWWA
PIPING MATERIAL LIST NOTES:

2. PROVIDE ISOLATION GASKETS BETWEEN DISSIMILAR METALS.

PIPINHG AND EQUIPMENT.

LISTED OR SHOWN. CONTRACTOR SHALL FURNISH AND INSTALL ALL

REDUCERS, BUSHINGS AND PIPE SUPPORTS OR HANGERS ARE NOT

REQUIRED FITTINGS SUCH AS UNIONS, GASKETS, BOLTS, ELBOWS,

1. THE PIPE MATERIAL LIST FOR THIS DETAIL IS NOT COMPLETE, MANY NOTES:

SYSTEMS CO. MODEL 2.5 H-SS-90.

1. NOZZLE - FULL CONE SPRAY PATTERN. 140 GPM @ 19 PSI, SPRAYING 11 1
2 TYP
M203 (TYP)
NOZZLE
2 1'-0"
12 3
4 9
20 10
DI
316 STN STL
12 17
13 15
18 11
16 19
7 8
14 3
6 5
JD
79 eparker
Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:27-04'00'

Page 344 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:27:00
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
87M01
eparker
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

EYY
ELP

MECHANICAL
8660F10 8660F1087M01.dgn
B
8660F1087M0301

PLAN AND SECTION
GENERAL NOTES:
# KEY NOTES:

BACKWASH PUMP STATION
B
-
2 A
-
8660F1087M0101
3/8"=1'-0"
1/4"=1'-0"
1 3 1
2 3
EX-3/4" FE
EX-1" FE
EX-1 1/2" FE
EX-1 1/2" FE
EX-14" BW
14" BW
EX-4" BW
14" BW
# KEY TAGS:

1. PMP-87134

2. AE-87130

BACKWASH CHLORINE SAMPLE PUMP
CHLORINE ANALYZER 3
4 5 8" BFV
TYP
(TYP)MP637
M
14" BFV (TYP) 3
4 3. FV-87130 HIGH RATE BACKWASH VALVE

4. FV-87230

5. FV-87330

HIGH RATE CONTROL VALVE

LOW RATE CONTROL VALVE
(TYP.)
14"X8" CONC. RED.

4. TIE INTO EXISTING PIPE.

EQUIPMENT TO THE EXISTING SAMPLE LINES AS REQUIRED.

3. SUPPLY ADDITIONAL PIPING AND FITTINGS TO CONNECT NEW INFORMATION.

AND INSTRUMENTATION (60N01) DRAWINGS FOR ADDITIONAL
EXISTING ENCLOSURE IN PLACE. REFER TO ELECTRICAL (60E01) 17505. THE EXISTING ENCLOSURE IS TO REMAIN IN USE, PROTECT

2. REPLACE CHLORINE ANALYZER 4 PER SPECIFICATION SECTION

1. RELOCATE THE EXISTING BUTTERFLY VALVE AS SHOWN.

FABRICATION.

CONTRACTOR AND APPROVED BY THE ENGINEER PRIOR TO

3. PIPE LAYOUT DRAWINGS SHALL BE PREPARED BY THE

2. SEE CIVIL DRAWINGS FOR YARD PIPING CONTINUATION.

CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS.

1. BACKGROUND IS BASED ON THE 2005 RECORD DRAWINGS.

JD
80 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:32-04'00'

Page 345 of 599 ends

4'-0"±

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:09
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
89M01
eparker
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CA
ELP

MECHANICAL
8660F10 8660F1089M01.dgn
A
#
GENERAL NOTES:

KEY NOTES:

B
3/8" = 1'-0" - 1/2" = 1'-0"
B
-

CAROUSEL PUMP STATION

PLAN AND SECTION
8660F1089M0101
16" SE
EX-36" SE
PMP-89100
EX-12" SE
EX-24" SE
EX-36" SE
EX-16" SE
EX-16" SE
EX-16" SE
EX-48" SE
EX-24" SE
1 1
8660F1089M0301
EX-36" SE
16" SE
# KEY TAGS:

3. CAROUSEL PUMP NO. 3

2. CAROUSEL PUMP NO. 2

1. CAROUSEL PUMP NO. 1
PMP-89101
PMP-89102
1 2
2 3
PUMP NO. 3

CAROUSEL
2 2
16" DMJT
16" SCV
16" BFV
TO PAU
3 TYP
MP034
MATCH LINE STA 10+04.73 ON DWG 91C07
CL 582.50 1

3. SEE CIVIL DRAWINGS FOR YARD PIPING CONTINUATION.

AND ORIENTATION OF VALVES AND VALVE ACTUATORS.

2. CONTRACTOR SHALL COORDINATE WITH THE CITY, THE LOCATION, BOLTS, AND GASKETS.

EXISTING PIPING COMPONENTS. DO NOT REUSE THE OLD NUTS,

FOR ALL CONNECTIONS, INCLUDING REINSTALLATION OF ANY

1. CONTRACTOR SHALL PROVIDE NEW NUTS, BOLTS, AND GASKETS

3. WATER LEVEL PER THE 1994 RECORD DRAWINGS.

2. PROVIDE NEW MOTOR FOR PUMP.

1. FOR PIPING ELEVATION REFER TO DWG 91C07.

JM
81 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:37-04'00'

Page 346 of 599 ends

1'-0"
5'-0"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
P
lotD
ate: 06-APR
-2023 1:26:56
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
91M01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

AL

MECHANICAL

PLAN AND SECTION
8660F10 8660F1091M01.dgn
#
GENERAL NOTES:

KEY NOTES:

A
B
- 3/8" = 1'-0"
3/8" = 1'-0"
8660F1091M0101
8660F1091M0301
CA

PAU PUMP STATION
B
-
TYP
MP370
# KEY TAGS:
1 10" SE
TYP
10" BFV
10" SCV
10" DMJT

SLIDE GATE

OPERATED

MANUALLY
10" RFCA
MP034
TYP
MP032
10" SE
16" SE
PV
C
D
IP

1. PMP-91100 PAU PUMP NO.1

FROM PAU
INV 569.03
M
IN
TYP
(TYP)MP370
CL 584.15
eparker
MATCH LINE STA 10+02 ON DWG 91C08
TOC 565.00
1 3. SEE CIVIL DRAWINGS FOR YARD PIPING CONTINUATION.

AND ORIENTATION OF VALVES AND VALVE ACTUATORS.

2. CONTRACTOR SHALL COORDINATE WITH THE CITY, THE LOCATION, BOLTS, AND GASKETS.

EXISTING PIPING COMPONENTS. DO NOT REUSE THE OLD NUTS,

FOR ALL CONNECTIONS, INCLUDING REINSTALLATION OF ANY

1. CONTRACTOR SHALL PROVIDE NEW NUTS, BOLTS, AND GASKETS TOC 582.00
TOP OF BERM 581.00

RELIEF VALVE
1" AIR
16" SE

1. REFER TO DRAWING 91C08 FOR PIPING ELEVATION.

JM
82 Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:43-04'00'

Page 347 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate:3/3/202312:37:22
PM
GENERAL NOTES:

KEY NOTES:

UNLESS NOTED OTHERWISE.

1. ALL GROOVED END COUPLINGS TO BE RIGID
HMI. PROVIDE PROTECTIVE COVER.

3. SIDE MOUNT PRESSURE INDICATOR WITH
BLIND FLANGE ON PUMP CAN.

FOR FUTURE PUMP INSTALLATION. INSTALL

2. INSTALL UPSTREAM PIPING AND PUMP CAN
SUPPLIED.

EQUIPMENT

BY THE CONTRACTOR TO SUIT THE

1. FINAL DIMENSIONS SHALL BE COORDINATED
CA
BB
JM
99M01
83 MECHANICAL

RECYCLED WATER PUMP STATION

PLAN, SECTION AND DETAIL
8660F1099M01.dw
g
eparker 8660F10
(TYP)
FUTURE
C
99M02
B
-
FE-99411
SCALE:

FILE:

A PLAN
99C19 1/4" = 1'-0"
8660F1000M100
SCALE:

FILE:

B SECTION
- 3/8" = 1'-0"
8660F1000M100

VERTICAL PUMP

TURBINE
-
1 12" RW
16" RW
TYP
MP034
(TYP)
TYP
MP032
14" RW
16" RW
CL 592.00
CL 605.83
SCALE:

FILE:
1 DETAIL
- NO SCALE
-

VERTICAL PUMP MOUNTING
3/4" GAVL STEEL PIPE

AIR RELEASE VALVE
3/4" BALVE VALVE
3/4" 3000 LF FS HALF

COUPLING SHOP WELDED

TO SOUTH SIDE OF PUMP

BASE PLATE

PIPE TO SLAB

PUMP BASE PLATE
TYPE 316 SS W/ NUT AND WASHER

LOCKWASHER OR DOUBLE NUTS
(LENGTH AS REQUIRED)

PROJECT MIN TWO THREADS

ABOVE NUT (TYP)

LEVELING PLATE THICKNESS PER

MANUFACTURER
2" NON-SHRINK GROUT

PUMP PAD
TYPE 316 SS ANCHOR BOLT W/
TWO TYPE 316 SS HEX NUTS AND
LOCKWASHERS FOR LEVELING.

EMBEDMENT AND ANCHOR BOLT

SIZE PER PUMP MANUFACTURER

REQUIREMENTS
TYPE 316 SS BAR 4x4x1/2" (MIN)

TACK WELD TO BOLT
TYPE 316 SS NUT

STEEL PUMP CAN

SEAL WELD

MACHINED GROOVE

AND O-RING SEAL

FROM TANK
1 PMP-99411
PMP-99412
PMP-99413
PMP-99414
PMP-99415
12" RW
16" RW

TO DISTRIBUTION SYSTEM
SEE DWG 99C19 FOR

CONTINUATION
16" RW
FSL-99411
FSL-99412
FSL-99413
FSL-99414
3 PIT-99432
PSH-99432
16" RW
4'-6" 11'-0" 4'-6" 6'-6"
10'-0" 10'-0" 10'-0"
5'-1"
10'-0" 8'-5" 5'-6"

VERTICAL

TURBINE

PUMP (TYP)
14" BFV
(TYP)
12" BFV
(TYP)
(TYP)
12" SWING

CHECK (TYP)
16"x12" REDUCING
BEND
16"x14" RED

A / V VALVE
(TYP)
14" FC
16"x12" RED

TEE (TYP)

FLOW SWITCH

RIGID GROOVED

END COUPLING
12" FLEXIBLE

EXPANSION JOINT

VALVE BOX AND

STEM RISER
16" TEE (TYP)
16" RW
16"x12" REDUCING
BEND
12" MAG METER

A / V VALVE
(TYP)
TYP
MP034

RIGID GROOVED

END COUPLING (TYP)
16"x12" RED
12" RW 2
16" BF
16" RW
14" RW
(TYP)
12" BF
#
PI-99411
PI-99412
PI-99413
PI-99414

PRESSURE
GAUGE
Digitally signed by Reace P. Fisher
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:09:12-07'00'

Page 348 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate:3/3/202312:38:51
PM
GENERAL NOTES:

UNLESS NOTED OTHERWISE.

1. ALL GROOVED END COUPLINGS TO BE RIGID
CA
BB
JD
99M02
84 MECHANICAL

RECYCLED WATER PUMP STATION

SECTION
8660F1099M02.dw
g
eparker 8660F10
SCALE:

FILE:

C SECTION
99M01 3/8" = 1'-0"
8660F1000M100
16" RW
(TYP)
TYP
MP034
TO

DISTRIBUTION
SYSTEM
CL 592.00 (TYP)

PUMP CAN (TYP)

CONCRETE ENCASE

PUMP CAN (TYP)

CONC CAN BASE

SUPPORT (TYP)
EL 588.00 (TYP)
14" RW
(TYP)

RIGID GROOVED

END COUPLING (TYP)

VERTICAL TURBINE

PUMP (TYP)
16"x12"

REDUCING
BEND

A / V VALVE
12" MAGNETIC

FLOW METER
16"x12" RED

FUTURE VERTICAL
TURBINE PUMP\
16" RW
Digitally signed by Reace P. Fisher
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:09:41-07'00'

Page 349 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate:3/3/202312:39:59
PM
KEY NOTES:

5. RIGID GROOVED END COUPLING

4. 12"X16" REDUCING BEND

3. A / V VALVE (TYP)
SECTION 15117

2. 12" TANK FILL VALVE PER SPECIFICATION

1. 12" MAGNETIC FLOW METER
#
RPF
BB
JM
99M03
85 MECHANICAL

METER AND CONTROL VALVE

PLAN AND SECTION
8660F1099M03.dw
g
eparker 8660F10
SCALE:

FILE:

E METER & CONTROL VALVE SECTION
- 3/8=1'-0"
8660F10M03
SCALE:

FILE:

D METER & CONTROL VALVE PLAN
99C19 3/8=1'-0"
8660F10M03

TO TANK INLET
SEE DWG 99C19
4 -
E

FROM RW DISTRIBUTION
SYSTEM SEE DWG 99C19

FOR CONTINUATION
16" PW
3'-6"
3 2
1 5
(TYP)
3 4
18" PW
TYP
12" S300
THICK
TYP
(TYP) MP034
5'-0" MIN. 3'-0" MIN.
2 VAL-99402
1 FIT-99406
16" RW
4 3
TYP
MP034 (TYP)
5 (TYP)
4 3
16" RW
VAL-99402
FIT-99406

FROM RW DISTRIBUTION
SYSTEM SEE DWG 99C19

FOR CONTINUATION
CL=603.83
TOC=603.33
CL=595.00+/- CL=590.00

TO TANK INLET
SEE DRAWING 99C19
6'-0"
19'-2"
Digitally signed by Reace P. Fisher
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:10:09-07'00'

Page 350 of 599 ends

3'-4"
3'-4"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405

REFRIGERANT LINES (TYP)
CU-99421 2
FCU-99422 1
3 3
TYP
HE620
18" DRYWELL
CU-99422 2
GENERAL NOTES:

1. MOUNT THERMOSTATS AT 48'' AFF AND LABEL
WITH ITS CONTROLLING DEVICE.

2. REFRIGERANT AND CONDENSATE DRAIN PIPING

SHALL NOT BE ROUTED ABOVE ELECTRICAL
EQUIPMENT. REFRIGERANT PIPING SHALL BE
INSULATED PER SPECIFICATION 15000.

3. PIPE SUPPORTS SHALL BE INSTALLED PER DETAIL
MP132/TYP, MP218/TYP, AND MP215/TYP. INSTALL
WALL PENETRATIONS PER DETAIL MP302/TYP.

KEY NOTES:
1 MINI-SPLIT FAN COIL UNIT SUSPENDED FROM
CEILING. BOTTOM OF UNIT AT 10'-0 AFF.
2 OUTDOOR CONDENSER UNIT. MOUNT UNIT ON
EQUIPMENT PAD PER S300/TYP.
3 1'' SCHEDULE 40 PVC CONDENSATE DRAIN
ROUTED TO 18'' DRYWELL. SLOPE LINES AT A
MINIMUM OF 2% SLOPE.
4 ROUTE REFRIGERANT LINES DOWN INTERIOR SIDE
OF WALL.
#
T
4 T
FCU-99422
TO
FCU-99421
TO
1 FCU-99421
P
lotD
ate:3/3/202312:41:13
PM
TCW
AMT
JM
99M04
86 MECHANICAL

ELECTRICAL BUILDING

HVAC FLOOR PLAN AND SCHEDULE
8660F1099M04.dw
g
eparker 8660F10
F
8660F1000H0101
1/2" = 1'-0"
TYP
S300 (TYP)
Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:57:48-04'00'

Page 351 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE-LINE SYMBOLS

DUPLEX RECEPTACLE

QUADRUPLEX RECEPTACLE
DUPLEX RECEPTACLE w/SPLIT WIRE

WELDING RECEPTACLE

SPECIAL PURPOSE RECEPTACLE

TWIST LOCK RECEPTACLE

TELEPHONE OUTLET

DATA COMMUNICATIONS OUTLET

LUMINAIRE IDENTIFICATION

LUMINAIRE, EMERGENCY/EXIT BATTERY-POWERED

LUMINAIRE, EMERGENCY BATTERY-POWERED REMOTE
(PERTAINS ONLY TO SHEET WHERE NOTE IS FOUND)

LUMINAIRE, EMERGENCY BATTERY-POWERED

LUMINAIRE, SURFACE OR PENDANT MOUNTED

LUMINAIRE, FLOOD/SPOT
LUMINAIRE, EXIT ONE OR TWO FACES AS INDICATED.

ARROW POINTS IN DIRECTION OF EGRESS.

LUMINAIRE, WALL WASHER
2' X 2' LAY-IN TROFFER
2' X 4' LAY-IN TROFFER

LUMINAIRE POLE MOUNTED

PHOTOCELL
MOTOR

EQUIPMENT/INSTRUMENT LOCATOR

EXPOSED CONDUIT

EXPOSED CONDUIT HIDDEN BEHIND WALLS,

FLOORS OR OTHER STRUCTURES

UNDERGROUND CONDUIT, DIRECT BURIED

CONDUIT VERTICAL CHANGE IN DIRECTION

JUNCTION BOX

CONDUIT SEAL

MEDIUM VOLTAGE

DISCONNECT SWITCH

NON-FUSED CUT OUT

MEDIUM VOLTAGE

DISCONNECTING FUSE

SINGLE FUSE CUT OUT

MEDIUM VOLTAGE

DISCONNECTING FUSE

DOUBLE FUSE CUT OUT

MEDIUM VOLTAGE SINGLE FUSE

MEDIUM VOLTAGE DOUBLE FUSE

MEDIUM VOLTAGE
FUSE

LIVE FRONT TERMINATOR

MEDIUM VOLTAGE ELBOW

UTILITY METER

CAPACITOR

BATTERY

LIGHTNING ARRESTER
GROUND

AMPERE TEST POINT

VOLTAGE TEST POINT

GROUNDED WYE CONNECTION

DELTA CONNECTION

GROUND ROD

SOLID STATE

MULTIFUNCTION METER

GROUND ROD AND GROUND WELL

IDENTIFICATION SYMBOLS MEDIUM VOLTAGE LOW VOLTAGE MISCELLANEOUS

GROUNDING

LUMINAIRES

SWITCHES/RECEPTACLES RACEWAY

LUMINAIRE, WALL MOUNTED

CONDUIT IDENTIFICATION
XXXX = CONDUIT NUMBER,

REFER TO CONDUIT SCHEDULE

APPROXIMATE DIMENSIONS

EQUIPMENT ENCLOSURE

MOV-ELBOW ARRESTER

MEDIUM VOLTAGE CONTACTOR

MEDIUM VOLTAGE STARTER

KIRK KEY INTERLOCK
a
b
c

FIRE ALARM CONTROL PANEL

FIRE ALARM PULL STATION

FIRE ALARM HORN/STROBE COMBINATION

FIRE ALARM STROBE

CONDUIT SIZE AND CONDUCTORS
W"C (WHERE INDICATED): W = CONDUIT TRADE SIZE
U = NUMBER OF PARALLEL RUNS

IN FLOOR QUADRUPLEX RECEPTACLE

FIBER OPTIC CABLES
FO/N
N = NUMBER OF INDIVIDUAL FIBERS

INDIVIDUAL CONDUCTORS

IN FLOOR DUPLEX RECEPTACLE

ENGINE-GENERATOR RATINGS AS INDICATED ON

THE DRAWINGS

CURRENT TRANSFORMER WITH

SHORTING TERMINAL BLOCK

DISCONNECT SWITCH

LOW VOLTAGE CIRCUIT BREAKER

AUXILIARY OPERATOR
* = S = SHUNT TRIP
= G = GROUND FAULT INTERRUPTER
= V = SOLENOID KEY RELEASE

CIRCUIT BREAKER, MEDIUM VOLTAGE

ANSI RELAY DEVICE
52 a
b
a
b
b
a
b
c
d
e
a
f
c
d
e
J
FACP
F
F
F
F
b
a
HP
~
G
c
b
a
d
e
a
b
a
b
ATP
SSM
VTP
*
b
B
A

CONDUIT IN SLAB
b
c
a

DRAWOUT CONNECTION
f
g
h

TRANSFORMER
a = DEVICE I.D.
b = KVA RATING
c = NUMBER OF PHASES
d = PRIMARY VOLTAGE
e = SECONDARY VOLTAGE
f,g= CONNECTION TYPE SYMBOL
h = IMPEDANCE

PACKAGED EQUIPMENT

LOAD RATING AS INDICATED
c d

POTENTIAL TRANSFORMER
a = QUANTITY
b = RATIO
c,d = CONNECTION TYPE SYMBOL 3 = QUANTITY
X = SIZE OF CONDUCTORS
(Ø) = DESIGNATES PHASE CONDUCTORS
1 = QUANTITY
Y = SIZE OF CONDUCTORS
(N) = DESIGNATES NEUTRAL CONDUCTORS
1 = QUANTITY
Z = SIZE OF CONDUCTORS
(G) = DESIGNATES GROUND CONDUCTORS
a
b
2 = DOUBLE POLE SWITCH
3 = THREE-WAY SWITCH
4 = FOUR-WAY SWITCH
K = KEY OPERATED SWITCH
F = SWITCH AND FUSESTAT HOLDER
P = SWITCH AND PILOT LIGHT
T = THERMOSTAT
D = DIMMER SWITCH
L = LOW VOLTAGE LIGHT SWITCH
M = MANUAL MOTOR STARTER

SINGLE POLE SWITCH
a
b = DEVICE SWITCHED DESIGNATION
= CIRCUIT DESIGNATION

SWITCH AND SINGLE RECEPTACLE

DISCONNECT SWITCH

SMOKE DETECTOR
= TYPE
= IONIZATION
= PHOTOELECTRIC
= DUCT DETECTOR

FIRE SPRINKLER
F = FLOW SWITCH
T = TAMPER SWITCH

MULTI CONDUCTOR CABLES
K/2/C#16S
K (WHERE INDICATED) = NUMBER OF PAIRS
2/C#16S = TWO CONDUCTOR, 16 GAUGE, TWISTED

SHIELDED PAIR
K/3/C#16S
K (WHERE INDICATED) = NUMBER OF TRIPLETS
3/C#16S = THREE CONDUCTOR, 16 GAUGE, TWISTED

SHIELDED TRIPLETS
N = NUMBER OF CONDUCTORS IN THE CABLE
X = SIZE OF CONDUCTORS

LOW VOLTAGE CIRCUIT BREAKER

COMBINATION STARTER

WITH CONTROL POWER TRANSFORMER

SPD SURGE PROTECTIVE
DEVICE
W"C-(3-X (Ø), 1-Y (N) & 1-Z (G))
EQUIP #

UNDERGROUND GROUND CABLE
3-X (Ø):
1-Y (N)(WHERE INDICATED):
1-Z (G)(WHERE INDICATED):

U{3-X (Ø) & 1-X (G)}
N/CX
b
a
a
b
b
a
b
a
b
a
b
a
b
a
a
b
a
b
a
PE
c
ab
a
B
K

LOAD BANK
da
XXXX

CONDUIT CAP

CONDUIT TEE
ARE LABELED LEFT TO RIGHT OR TOP TO BOTTOM.

X
c
b a

BREAK AND CONTINUATION IN CONDUIT RUN

MEDIUM VOLTAGE TEE

FIRE ALARM

APPLIANCE RECEPTACLE

INDICATES KEYNOTE X
X

EQUIPMENT AND INSTRUMENT IDENTIFICATION
#4/0 SDBC UNLESS OTHERWISE NOTED

UNLESS OTHERWISE NOTED, GROUPED CONDUITS
d
R H
3P= THREE POSITION SWITCH

OCCUPANCY SENSOR
c
b a
X

R G GO/NO-GO PANEL - SOLID

R GO/NO-GO PANEL - STROBE
c = TYPE

REFER TO ABBREVIATIONS LEGEND

OR IN DUCT BANK

DUCT BANK

SHOWN ON DUCT BANK SECTIONS

GO/NO-GO PANEL - STROBE AND HORN
= CIRCUIT DESIGNATION
= DEVICE SWITCHED FROM
= MOUNTING HEIGHT IN FEET TO

BOTTOM OF FIXTURE
FOR ALL OTHER DESIGNATIONS.
= REFERENCE LIGHTING CONTROL COMPONENT SCHEDULE
= CIRCUIT DESIGNATION
= DEVICE SWITCHED DESIGNATION
= MOUNTING HEIGHT IN FEET TO BOTTOM OF SENSOR
X
a
b
c
= CIRCUIT DESIGNATION
b = DEVICE TYPE DESIGNATION
a
= CIRCUIT DESIGNATION
b
a
= DISCONNECT TYPE
a = AMP RATING
= CIRCUIT DESIGNATION
b
a
= MOUNTING HEIGHT
= CIRCUIT DESIGNATION
b
a
= MOUNTING HEIGHT
d
P
I
a
= CIRCUIT BREAKER NUMBER
= FRAME SIZE
= ANSI DEVICE FUNCTION
= QUANTITY
b
a
a
b

TYPE AS NOTED

FUSED DISCONNECT SWITCH
MCP = MOTOR CIRCUIT PROTECTOR
TM = THERMAL MAGNETIC
SS = SOLID STATE

FRAME SIZE UNLESS INDICATED)
(AT = AMP TRIP)
(AC = MCP CONTINUOUS RATING)
a = TYPE
b = FRAME SIZE (MANUFACTURER TO DETERMINE
c = NUMBER OF POLES
d = TRIP SETTING
e = DESIGNATION
f = INTERRUPTING RATING
A = TYPE, REFER TO DISCONNECT SCHEDULE
b = FUSE RATING
B = TYPE, REFER TO DISCONNECT SCHEDULE
a = CIRCUIT BREAKER DISCONNECT,
b = STARTER TYPE
c = NEMA STARTER SIZE
d = OVERLOAD

FULL LOAD AMPS AS NOTED
HP = HORSEPOWER RATING
a = RATED LOAD
b = UNIT(HP, KW, KVA) AS INDICATED
a = QUANTITY
b = RATIO
a = KVA/KW
b = VOLTAGE/CONNECTION
c = PHASE
d = WIRE
e = PF
a
MOTOR STARTER/DRIVES:
b
c
VFD-6
VFD-18 = 18-PULSE VFD
= 6-PULSE VFD
RVSS
RVAT
a/B
= LINE REACTOR
PHF = PASSIVE HARMONIC FILTER
LL
LR = LOAD REACTOR
DV/DT = Dv/dt FILTER
SWF = SINE WAVE FILTER
a = DEVICE TYPE
b
c
= REDUCED VOLTAGE SOLID

STATE STARTER
= REDUCED VOLTAGE AUTO

TRANSFORMER
= DEVICE WITH BYPASS
STARTER. REFER TO

THE SPECIFICATIONS

LINEAR FIXTURE
N = NETWORKED SINGLE OR

MULTIPLE SWITCH LOCATIONS
R = RED LIGHT
G = GREEN LIGHT
H = HORN
= INPUT OPTIONS
= OUTPUT OPTIONS
VFD-RH = REDUCED HARMONIC VFD
P
lotD
ate: 05
-APR
-2023 12:58:17
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
LEGEND
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE
CE

ELECTRICAL
00GE01
8660F10 8660F1000GE01.dgn
87 avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:17:51-07'00'
200

Page 352 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

ABBREVIATIONS
NOTES:
94 TRIPPING OR TRIP-FREE RELAY
93 FIELD-CHANGING CONTACTOR
92 VOLTAGE AND POWER DIRECTIONAL RELAY
91 VOLTAGE DIRECTIONAL RELAY
90 REGULATING DEVICE
89 LINE SWITCH
88 AUXILIARY MOTOR OR MOTOR GENERATOR
87 DIFFERENTIAL PROTECTIVE RELAY
86 LOCKOUT RELAY
85 PILOT COMMUNICATIONS, CARRIER OR PILOT-WIRE RELAY
84 OPERATING MECHANISM
83 AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY

P PHASE PROTECTION

V VOLTAGE

T TRANSFORMER PROTECTION
(RELAY COIL CONNECTED IN RESIDUAL CT CIRCUIT)

N GROUND FAULT PROTECTION

M MOTOR PROTECTION

L LINE PROTECTION
(RELAY CT IN TOROIDAL OR GROUND SENSOR TYPE)

GS GROUND FAULT PROTECTION
(RELAY CT IN A SYSTEM NEUTRAL CIRCUIT OR GENERATOR PROTECTION)

G GROUND FAULT PROTECTION

B BUS PROTECTION

A ALARM ONLY

ABBREVIATIONS

POWER DEVICE FUNCTION NUMBERS

POWER DEVICE FUNCTION NUMBERS

COMMONLY USED SUFFIX LETTERS APPLIED TO

SYM SYMMETRICAL

SWGR SWITCHGEAR

SWBD SWITCHBOARD

SW SWITCH

STB SHORTING TERMINAL BLOCK

SS SOLID STATE

SPKR SPEAKER

SPST SINGLE POLE SINGLE THROW

SPDT SINGLE POLE DOUBLE THROW

SPD SURGE PROTECTIVE DEVICE

SP SINGLE POLE

SM SURFACE MOUNTED

SLT SEALTIGHT LIQUIDTIGHT FLEXIBLE CONDUIT

SFL SUB FEED LUGS

SDBC SOFT DRAWN BARE COPPER

SC SHORT CIRCUIT

SA SURGE ARRESTER

S SHIELD / SHORT-TIME

RVSS REDUCED VOLTAGE SOLID STATE

RVNR REDUCED VOLTAGE NON-REVERSING

RVAT REDUCED VOLTAGE AUTO TRANSFORMER

RMS ROOT MEAN SQUARED

RF RADIO FREQUENCY

REV REVERSE

RECPT RECEPTACLE

RAC RIGID ALUMINUM CONDUIT

PWR POWER

PVC POLYVINYL CHLORIDE RIGID PLASTIC CONDUIT

PT POTENTIAL TRANSFORMER

PRI PRIMARY
PPX POWER PANEL NO. X

PNL PANEL

PH PHASE

PFR PHASE FAILURE RELAY

PFCC POWER FACTOR CORRECTION CAPACITOR

PF POWER FACTOR

PE PHOTOCELL

PCM PROCESS CONTROL MODULE

PCS PVC COATED GALVANIZED STEEL CONDUIT

PB PUSHBUTTON / PULL BOX

PA PUBLIC ADDRESS
P POLE

OL OVERLOAD RELAY

OH OVERHEAD

O OPEN OR OPENED

NP NAMEPLATE

NO NORMALLY OPEN

NL NIGHT LIGHT

NFC NONMETALLIC FLEXIBLE CONDUIT

NEC NATIONAL ELECTRICAL CODE

NC NORMALLY CLOSED

N NEUTRAL

MW MEGAWATT

MVS MEDIUM VOLTAGE SWITCH

MVA MEGAVOLT-AMPERES

MV MEGAVOLT

MTS MANUAL TRANSFER SWITCH
MTR-X MOTOR NO. X

MTO MANUAL THROW OVER

MSP MOTOR STARTING PANEL
MS-X MOTOR STARTER NO. X

MPR MOTOR PROTECTION RELAY

MOV METAL OXIDE VARISTOR

MOD MOTOR OPERATED DAMPER

MLO MAIN LUGS ONLY

MH MANHOLE / MOUNTING HEIGHT

MCP MOTOR CIRCUIT PROTECTOR
MCC - X MOTOR CONTROL CENTER NO. X

MCA MOTOR CIRCUIT AMPS

MA MILLIAMPERE
M-X MOTOR CONTROLLER NO. X

LVL LEVEL

LV LOW VOLTAGE

LTG LIGHTING
LP - X LIGHTING PANEL NO. X

LP LIGHT POLE

LL LEAD-LAG LOAD REACTOR
LCP- X LOCAL CONTROL PANEL NO. X

LC LIGHTING CONTACT OR

LBL LABEL

LA LIGHTNING ARRESTOR

L-G LINE-GROUND

L-B LINE-BUS

L LONG-TIME

KWH KILOWATT HOUR

KWD KILOWATT DEMAND

KW KILOWATT

KVAR KILOVAR (REACTANCE)

KVA KILOVOLT AMPERE

KV KILOVOLT

KA KILOAMP

K KEY INTERLOCK

J JUNCTION BOX
82 DC LOAD MEASURING RECLOSING RELAY
81 FREQUENCY RELAY
80 FLOW SWITCH
79 AC RECLOSING RELAY
78 PHASE-ANGLE MEASURING RELAY
77 TELEMETERING DEVICE
76 DC OVERCURRENT RELAY
75 POSITION CHANGING MECHANISM
74 ALARM RELAY
73 LOAD-RESISTOR CONTACTOR
72 DC CIRCUIT BREAKER
71 LIQUID LEVEL SWITCH
70 RHEOSTAT
69 PERMISSIVE CONTROL DEVICE
68 BLOCKING OR OUT OF STEP RELAY
67 AC DIRECTIONAL OVERCURRENT RELAY
66 NOTCHING OR JOGGING DEVICE
65 GOVERNOR
64 GROUND DETECTOR RELAY
63 PRESSURE SWITCH
62 TIME-DELAY STOPPING OR OPENING RELAY
61 DENSITY SWITCH OR SENSOR
60 VOLTAGE OR CURRENT BALANCE RELAY
59 OVERVOLTAGE RELAY
58 RECTIFICATION FAILURE RELAY
57 SHORT-CIRCUITING OR GROUNDING DEVICE
56 FIELD APPLICATION RELAY
55 POWER FACTOR RELAY
54 TURNING GEAR ENGAGING DEVICE
53 FIELD EXCITATION RELAY
52 AC CIRCUIT BREAKER
51 AC TIME OVERCURRENT RELAY
50 INSTANTANEOUS OVERCURRENT RELAY
49 MACHINE OR TRANSFORMER THERMAL RELAY
48 INCOMPLETE SEQUENCE RELAY
47 PHASE-BALANCE OR PHASE-SEQUENCE VOLTAGE RELAY
46 REVERSE-PHASE OR BALANCE CURRENT RELAY
45 ABNORMAL ATMOSPHERIC CONDITION MONITOR
44 UNIT SEQUENCE STARTING RELAY
43 MANUAL TRANSFER OR SELECTOR DEVICE
42 RUNNING CIRCUIT BREAKER
41 FIELD CIRCUIT BREAKER
40 FIELD RELAY
39 MECHANICAL CONDITION MONITOR
38 BEARING PROTECTIVE DEVICE
37 UNDERCURRENT OR UNDERPOWER RELAY
36 POLARITY DEVICE
35 BRUSH-OPERATING OR SLIP-RING SHORT-CIRCUITING DEVICE 34 MASTER SEQUENCE DEVICE
33 POSITION SWITCH
32 DIRECTIONAL POWER RELAY
31 SEPARATE EXCITATION DEVICE
30 ANNUNCIATOR RELAY
29 ISOLATING CONTACTOR
28 FLAME DETECTOR
27N GROUND FAULT UNDERVOLTAGE RELAY
27 UNDERVOLTAGE RELAY
26 APPARATUS THERMAL DEVICE
25 SYNCHRONIZING OR SYNCHRONISM-CHECK DEVICE
24 VOLTS PER HERTZ RELAY
23 TEMPERATURE CONTROL DEVICE
22 EQUALIZER CIRCUIT BREAKER
21 DISTANCE RELAY
20 ELECTRICALLY OPERATED VALVE
19 STARTING-TO-RUNNING TRANSITION CONTACTOR
18 ACCELERATING OR DECELERATING DEVICE
17 SHUNTING OR DISCHARGE SWITCH
16 DATA COMMUNICATIONS DEVICE
15 SPEED OR FREQUENCY MATCHING DEVICE
14 UNDER-SPEED DEVICE
13 SYNCHRONOUS-SPEED DEVICE
12 OVER-SPEED DEVICE
11 MULTIFUNCTION DEVICE
10 UNIT SEQUENCE SWITCH
9 REVERSING DEVICE
8 CONTROL POWER DISCONNECTING DEVICE
7 ANODE CIRCUIT BREAKER
6 STARTING CIRCUIT BREAKER
5 STOPPING DEVICE
4 MASTER CONTACTOR
3 CHECKING OR INTERLOCKING RELAY
2 TIME-DELAY STARTING OR CLOSING RELAY
1 MASTER ELEMENT

TCM - TRIP CIRCUIT MONITOR

SER - SEQUENCE OF EVENTS RECORDER

RTU - REMOTE TELEMETRY UNIT/REMOTE TERMINAL UNIT

RIO - REMOTE I/O DEVICE

PQM - POWER QUALITY MONITOR

PMU - PHASOR MEASUREMENT UNIT

PDC - PHASOR DATA CONCENTRATOR

MET - SUBSTATION METERING

LGC - SCHEME LOGIC

HST - HISTORIAN

HMI - HUMAN MACHINE INTERFACE

HIZ - HIGH IMPEDANCE FAULT DETECTOR

ENV - ENVIRONMENTAL DATA

DFR - DIGITAL FAULT RECORDER

DDR - DYNAMIC DISTURBANCE RECORDER

CLK - CLOCK OR TIMING SOURCE

AFD - ARC FLASH DETECTOR

1. REFER TO SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL ABBREVIATIONS.

INTERCOM INTERCOMMUNICATION

INT INTERLOCK

INST INSTANTANEOUS

IMC INTERMEDIATE METAL CONDUIT

IJB INSTRUMENT JUNCTION BOX

IC INTERRUPTING CAPACITY

I INSTANTANEOUS / INTERMITTENT LOAD

HZ HERTZ

HVAC HEATING/VENTILATION/AIR CONDITIONING

HV HIGH VOLTAGE

HSTAT HUMIDISTAT

HR HOUR

HPS HIGH PRESSURE SODIUM

HP HORSEPOWER

HF HIGH FREQUENCY

H HOT-LEG

GFR GROUND FAULT RELAY

GFI GROUND FAULT INTERRUPTER (BREAKER)

GFCI GROUND FAULT CIRCUIT INTERRUPTER (RECEPTACLE)

GRC GALVANIZED STEEL RIGID CONDUIT

GEN GENERATOR

G GROUND / EQUIPMENT GROUND / GROUND FAULT

FWD FORWARD

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

FU SW FUSED SWITCH

FU FUSE

FREQ FREQUENCY

FRC FIBERGLASS RIGID CONDUIT

FO FIBER OPTIC

FLX FLEXIBLE CONDUIT

FLA FULL LOAD AMPS

FDR FEEDER

FACP FIRE ALARM CONTROL PANEL

FA FIRE ALARM

F SUB-FED

ETM ELAPSED TIME METER

EP EXPLOSION PROOF

ENT ELECTRICAL NON-METALLIC TUBING

ENG ENGINE

ENCL ENCLOSURE

EMT ELECTRICAL METALLIC TUBING

EM EMERGENCY

E/G EMERGENCY GENERATOR

DS DOOR SWITCH

DPST DOUBLE POLE SINGLE THROW

DPDT DOUBLE POLE DOUBLE THROW

DM DEMAND METER

DISC DISCONNECT SWITCH

DEMO DEMOLITION
DCU - X DISTRIBUTED CONTROL UNIT NO. X

DCS DISTRIBUTED CONTROL SYSTEM

DC DIRECT CURRENT

CW CLOCKWISE / COOL WHITE

CV CONTROL VALVE

CT CURRENT TRANSFORMER

CS CONTROL SWITCH

CR CONTROLLED RECEPTACLE

CPT CONTROL POWER TRANSFORMER

COMM COMMUNICATION

COM COMMON

COAX COAXIAL CABLE

CKT CIRCUIT

CCW COUNTER CLOCKWISE

CCTV CLOSED CIRCUIT TELEVISION

CB CIRCUIT BREAKER

C CONDUIT / CONTINUOUS LOAD

BRF BELOW RAISED FLOOR

BKR BREAKER

BHP BRAKE HORSEPOWER

BFG BELOW FINISHED GRADE

BAT BATTERY
B BELL

AWG AMERICAN WIRE GAGE

AUX AUXILIARY

AUTO XFMR AUTOMATIC TRANSFORMER

ATS AUTOMATIC TRANSFER SWITCH

ATP AMMETER TEST POINT

ATO AUTOMATIC THROW OVER

AT AMP TRIP

ASYM ASYMMETRICAL

AS AMMETER SWITCH

ARM ARMORED CABLE

APU AUXILIARY POWER UNIT

ANT ANTENNA

ANN ANNUNCIATOR

AM AMMETER

AIC AMP INTERRUPTING CAPACITY

AFC AUTOMATIC FREQUENCY CONTROL

AF AMP FRAME

ACTR ACTUATOR

ACK ACKNOWLEDGE

AC ALTERNATING CURRENT

ABS ABSOLUTE
A AMP

XFMR TRANSFORMER

WP WEATHER PROOF

WT WATER TIGHT

W WATT / WEST

VTP VOLTAGE TEST POINT

VT VOLTAGE TRANSFORMER

VS VOLTAGE SWITCH

VR VOLTAGE REGULATOR

VP VAPORPROOF

VM VOLTMETER

VHF VERY HIGH FREQUENCY

VFD VARIABLE FREQUENCY DRIVE

VCP VENDOR CONTROL PANEL

VAR VARMETER

VA VOLT AMPERE
V VOLT

UVR UNDER VOLTAGE RELAY

UPS UNINTERRUPTIBLE POWER SUPPLY

UNG UNGROUNDED

UHF ULTRA HIGH FREQUENCY

TSTAT THERMOSTAT
TS2W TWO SPEED SEPARATE WINDING
TS1W TWO SPEED CONSEQUENT POLE, ONE WINDING

TS TEMPERATURE SWITCH

TP TWISTED PAIR

TM THERMAL MAGNETIC

TJB TERMINAL JUNCTION BOX

TERM TERMINAL

TENV TOTALLY ENCLOSED NON-VENTILATED

TEFC TOTALLY ENCLOSED FAN COOLED

TE TOTALLY ENCLOSED

TD TEMPERATURE DETECTOR RELAY

TC THERMOCOUPLE / TIME CLOCK / TRAY CABLE

TB - X TERMINAL BLOCK - UNIT X

TACH TACHOMETER
P
lotD
ate: 05
-APR
-2023 12:58:48
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE
CE

ELECTRICAL
00GE02

ABBREVIATIONS
8660F10 8660F1000GE02.dgn
bshepard
88 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:19:47-07'00'
200

Page 353 of 599 ends

HH-1
HH-2

BUILDING

ELECTRICAL

PUMP STATION

RECYCLED WATER
HH-4
HH-3

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
SS
W
SS
P
lotD
ate: 05
-APR
-2023 1:13:05
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
01E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1001E01.dgn
0 20' 40' 80'
A
02E01
A
02E01
A
02E01
A
99E01
C
99E03
B
99E02
D
99E04
JGB
G
99E14
F
99E13
E
99E12
TYP
EM001
TYP
EM001
1 # KEY NOTES:

STORAGE TANK

RECYCLED WATER

WTP PUMP STATION AND STORAGE SITE PLAN
avates

TREATMENT BLDG

EXISTING WATER
TYP
EM002
2 CROSSING UNDER THE DUCT BANK.

REDUCED DEPTH DUCT BANK TO ACCOMMODATE YARD PIPE

2. DUCT BANK SEGMENT BETWEEN HH-2 AND HH-3 SHALL BE BUILT AS FINISHED GRADE.

DUCT BANK AT THIS LOCATION SHALL NOT EXCEED 3'-6" BELOW

1. DUCT BANK CROSSES OVER YARD PIPE. DEPTH FOR BOTTOM OF B
02E01
89 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:37:40-07'00'
200

Page 354 of 599 ends

MV (E)
MV (E)
LV (E)
MV (E)

STRUCTURE

DE-CHLORINATION

FACILITY

CHLORINATION

FACILITY

DE-WATERING
SLUDGE

PUMP STATION

PROPOSED PAU
HH-20
HH-21

BUILDING

POWER GENERATION

STATION
PUMP

CAROUSEL
MV (N)
COUED-4

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
. 5710
572
572
572
572
574
574
574
574
SD
576
576
576
576
576
SD
WV
WV
WV
WV
578
578
578
578
WV
WV
WV
WV
WV
SS
WV
SS
WV
WV
SS
SS
SS
WV
WV
SS
P
lotD
ate: 05
-APR
-2023 1:11:36
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
01E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1001E02.dgn
A
12E01
A
80E01
85E01
A
70E01
A
A
91E01
A
87E01
89E02
B
60E01
A
0 10' 20' 30' 60'
B
91E01

WWTP AND STORAGE POND
BLDG.

EQUIP.

DAFT

FACILITY
AWT
I
02E01
J
02E02
K
02E02
H
02E01
89E01
A
M
02E03
M
02E03 M
02E03
L
02E02
P
02E03
1 2
1 JGB
01E03
01E03
Z
01E03
2 PED-983
3 Z
01E03
2 avates
R
02E03
FIT-88101
FIT-88102
4 4
L-88-101
S-88-101
L-88-102
S-88-102
5 Q
02E03
#
GENERAL NOTES:

KEY NOTES:

DETAIL EM015/TYP.

5. INSTALL CONDUITS UNDERGROUND ACCORDING TO TYPICAL
TYPICAL DETAIL EM104/TYP.

4. INSTALL CONDUITS ADJACENT TO HAND RAILS ACCORDING TO EXACT VAULT LOCATION WITH COUED.
16210 FOR UTILITY CONSTRUCTION DETAILS. COORDINATE THE
CONSTRUCTION DETAIL. REFER TO SPECIFICATION SETCTION

UKIAH ELECTRIC DEPARTMENT (COUED) MV VAULT

3. CONTRACTOR TO PROVIDE MV VAULT ACCORDING TO CITY OF
WITH CITY OF UKIAH ELECTRIC DEPARTMENT (COUED).

COORDINATE EXACT UNDERGROUND 12KV CONDUIT ROUTING
APPROXIMATE. CONTRACTOR SHALL MEET ON SITE AND
TRENCH SECTION. NEW 12KV ROUTING PROVIDED HERE IS

2. INSTALL UNDERGROUND 12KV CONDUITS ACCORDING TO
STRUCTURES OR UNDERGROUND EQUIPEMENT.

NEEDED TO ACCOMMODATE CONSTRUCTION OF NEW
DEMOLISH EXISTING UNDERGROUND 12KV CONDUITS WHERE
TRF-3E AND PEDESTAL PD-983 ARE REMOVED BY COUED,

1. AFTER EXISTING 12KV CONDUCTORS BETWEEN TRANSFORMER
SHALL VERIFY BEFORE EXCAVATION FOR NEW INSTALLATION.

MAY NOT REFLECT ACTUAL FIELD CONDITION. CONTRACTOR

1. EXISTING UNDERGROUND DUCT BANK AND CONDUIT ROUTING
PARTIAL SITE PLAN 90
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:20:11-07'00'
200

Page 355 of 599 ends

HH-13
MH-12
HH-11
HH-10

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:12:41
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
01E03
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1001E03.dgn
02E02
02E01
H2
02E01
H1
02E02
I1
02E02
I2
02E02
J2
02E02
K1
02E02
J2
02E02
K2
02E02
J1
02E02
K
02E02
J
02E01
H
02E01
I
1 JGB
1 01E02 1/4" = 1'-0"
8660F1001E0101
2 01E02 1/4" = 1'-0"
8660F1001E0101
J1
J 02E02
DWG 01E02

CONTINUED ON
D
W
G 01
E02
CON
TINU
ED ON
D
W
G 01
E02
CON
TINU
ED ON
DWG 01E02

CONTINUED ON
D
W
G 01
E02
CON
TINU
ED ON
# KEY NOTES:
avates

WWTP AND STORAGE POND SITE

PLAN DETAILS AND TRENCH SECTION
3 4
5 2
Z
01E02 NO SCALE
8660F1003E001
6 UNDERGROUND UTILITIES SHALL BE MINIMUM 12".

6. MINIMUM CLEARANCE BETWEEN 12KV CONDUITS AND OTHER
DRIVEWAY.

5. 2" CONCRETE COVER AT 12" BFG WHERE TRENCH IS UNDER

4. 4" CONDUIT FOR COUED 12KV LINE.

3. 4" CONDUIT FOR COUED 12KV SPARE.

FILL. PROVIDED SECTION IS SCHEMATIC ONLY.

SPCIFICATION SECTION 16210 FOR TRENCH DEPTH, SPACING AND

2. REFER TO UTILITY CONSTRUCTION DETAILS PROVIDED IN
DUCT BANK DRAINAGE.

1. SLOPE DUCT BANKS TOWARD THIS MANHOLE TO PROVIDE PROPER 91 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:23:26-07'00'
200

Page 356 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
GENERAL NOTES:

EM001/TYP UNLESS OTHERWISE INDICATED.

1. CONSTRUCT DUCT BANK IN ACCORDANCE WITH DETAIL
X-2054
(2")
X-2100
(2")
X-2101
(2")
X-3100
(2")
X-3104
(2")
X-3200
(2")
X-2021
(2")
X-2031
(2")
X-2041
(2")
X-2051
(2")
X-2052
(2")
X-2053
(2")
S-3102
(2")
N-3100
(2")
X-1500
(2")
X-1501
(2")
X-1502
(2")
X-2011
(2")
C-2015
(2")
S-2011
(2")
S-2021
(2")
S-2031
(2")
S-2041
(2")
S-2431
(2")
X-3100
(2")
X-3104
(2")
X-3200
(2")
C-3102
(2")
X-3101
(2")
S-3101
(2")
L-3102
(2")
L-3200
(2")
C-3105
(2")
C-2025
(2")
C-2035
(2")
C-2045
(2")
N-3100
(2")
X-1500
(2")
X-1501
(2")
X-1502
(2")
X-0010
(4")
X-0011
(4")
P-0010
(4")
P-0011
(4")
X-0010
(4")
X-0011
(4")
P-0010
(4")
P-0011
(4") P-2012
(2")
P-2022
(2")
P-2032
(2")
P-2042
(2")
L-2100
(2")
L-2431
(2")
L-3102
(2")
L-3200
(2")
C-3105
(2")
S-3102
(2")
Width: 3'-0"
Height: 1'-7"
Width: 3'-0"
Height: 2'-4"
Width: 3'-1"
Height: 3'-3"
Width: 2'-4"
Height: 2'-2"

A DUCT BANK SECTION B DUCT BANK SECTION C DUCT BANK SECTION D DUCT BANK SECTION 01E01, 01E01, 01E01, 99E01, 99E02, 99E12 01E01 99E02, 99E03, 99E12, 99E13 99E03, 99E13, 99E14 X-3102
(2")
X-3103
(2")
X-3100
(2")
C-3005
(2")
S-3200
(2")
N-3100
(2")
S-3200
(2")
X-3102
(2")
X-3103
(2")
X-91-100
(2")
X-91-102
(2")
C-91-110
(2")
X-91-100
(2")
L-3100
(2")
L-3101
(2")
L-3200
(2")
L-3101
(2")
L-3200
(2")
C-3005
(2")
P-91-101
(2")
L-91-100
(2")
C-91-110
(2")
P-91-101
(2")
L-91-100
(2")
X-91-102
(2")
Width: 1'-11"
Height: 2'-2"
Width: 1'-11"
Height: 1'-9"
Width: 1'-11"
Height: 1'-9"
Width: 1'-7"
Height: 1'-9"
Width: 1'-2"
Height: 1'-5"
E DUCT BANK SECTION F DUCT BANK SECTION H DUCT BANK SECTION H1 DUCT BANK SECTION H2 DUCT BANK SECTION 99E14 99E14 01E02, 01E03, 91E01, 91E01 01E03 01E03
P
lotD
ate: 05
-APR
-2023 1:40:56
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
02E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1002E01.dgn
DUCT BANK SECTIONS 1
bshepard
92 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:37:25-07'00'
200

Page 357 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
GENERAL NOTES:

EM001/TYP UNLESS OTHERWISE INDICATED.

1. CONSTRUCT DUCT BANK IN ACCORDANCE WITH DETAIL
X-89-100
(2")
X-89-101
(2")
X-89-120
(2")
X-89-125
(2")
X-89-100
(2")
X-89-120
(2")
X-89-110
(2")
X-89-112
(2")
S-89-102
(2")
N-60-112
(2")
L-89-111
(2")
C-89-120
(2")
S-89-101
(2")
N-60-111
(2")
P-89-131
(2")
L-89-111
(2")
C-89-120
(2")
X-89-101
(2")
X-89-125
(2")
P-91-101
(2")
L-89-112
(2")
C-89-120
(2")
C-91-111
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-131
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
S-89-101
(2")
N-60-111
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-132
(2")
Width: 2'-4"
Height: 2'-2"
Width: 1'-11"
Height: 2'-2"
Width: 1'-7"
Height: 1'-9"
Width: 2'-4"
Height: 2'-2"
I DUCT BANK SECTION I1 DUCT BANK SECTION I2 DUCT BANK SECTION J DUCT BANK SECTION NO MATCHING REF DWGS FOUND 01E03 01E03 01E02, 01E03, 01E03 X-89-110
(2")
X-89-112
(2")
X-89-111
(2")
X-89-113
(2")
S-89-102
(2")
N-60-113
(2")
X-89-111
(2")
X-89-113
(2")
P-91-101
(2")
L-89-112
(2")
C-89-120
(2")
C-91-111
(2")
P-91-101
(2")
L-89-113
(2")
C-89-120
(2")
C-91-111
(2")
P-91-101
(2")
L-89-113
(2")
C-89-120
(2")
C-91-111
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-132
(2")
S-89-102
(2")
N-60-112
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-133
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-133
(2")
S-89-102
(2")
N-60-113
(2")
Width: 2'-4"
Height: 2'-2"
Width: 1'-7"
Height: 1'-5"
Width: 2'-4"
Height: 2'-2"
Width: 2'-4"
Height: 2'-2"
Width: 1'-7"
Height: 1'-5"
J1 DUCT BANK SECTION J2 DUCT BANK SECTION K DUCT BANK SECTION K1 DUCT BANK SECTION K2 DUCT BANK SECTION 01E03, 01E03 01E03, 01E03 01E02, 01E03, 70E01 01E03 01E03 P
lotD
ate: 05
-APR
-2023 1:41:03
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

AH
NS

ELECTRICAL
DUCT BANK SECTIONS 2
8660F10 8660F1002E02.dgn
02E02
JGB
bshepard
93 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:20:28-07'00'
200

Page 358 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
GENERAL NOTES:

EM001/TYP UNLESS OTHERWISE INDICATED.

1. CONSTRUCT DUCT BANK IN ACCORDANCE WITH DETAIL
N-60-110
(2")
X-60-100
(2")
P-60-120
(2")
L-60-111
(2")
X-60-105
(2")
S-80-101
(2")
X-80-100
(2")
X-80-101
(2")
P-87-101
(2")
C-87-101
(2")
S-87-100
(2")
P-87-112
(2")
C-87-110
(2")
S-88-105
(2")
Width: 1'-11"
Height: 1'-9"
Width: 1'-11"
Height: 1'-5"
Width: 1'-11"
Height: 1'-5"
Width: 1'-11"
Height: 1'-5"

L DUCT BANK SECTION M DUCT BANK SECTION P DUCT BANK SECTION Q DUCT BANK SECTION NO MATCHING REF DWGS FOUND 01E02, 01E02, 01E02, 70E01, 80E01 01E02, 87E01 01E02, 87E01 C-87-110
(2")
S-87-100
(2")
S-88-105
(2")
P-87-101
(2")
P-87-112
(2")
C-87-101
(2")
Width: 1'-11"
Height: 1'-9"

R DUCT BANK SECTION
01E02, 85E03
P
lotD
ate: 05
-APR
-2023 1:41:08
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

AH
NS

ELECTRICAL
DUCT BANK SECTIONS 3
8660F10 8660F1002E03.dgn
02E03
JGB
bshepard
94 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:20:43-07'00'
200

Page 359 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
~
G
TM
2000 AT
3P
SSM
SPD
3 PHASE
750 KVA
SPARE
TM
1200 AT
3P
1200 AF
65 KAIC
TM
3P
30 AT 65 KAIC
TM
1200 AT
3P
1200 AF
65 KAIC
SPARE
TM
3P
65 KAIC
TM
400 AT
3P
65 KAIC
TM
200 AT
3P
65 KAIC
TM
225 AT
3P
65 KAIC
VFD

12000 V
480/277 V
65 KAIC
2000 AF
3 PHASE
4 WIRE
PR 0.8
480/277 V
655 KW

UTILITY

TO EXISTING
1200 AMPS
480 V, 3 PHASE, 3 WIRE
30 AT
ATS-E
MCC-N
MCC-E

VFD-XFR

MCC-XFR
1 MCC-RW
1 1
2 SWBD-A
XFMR-A
GEN-A
2000 AMPS, 480/277 V, 3 PHASE, 4 WIRE, 60 HZ, 65 KASC RMS 1200 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS 600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 42 KASC RMS 600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS TM
200 AT
3P
42 KAIC
TM
500 AT
3P
65 KAIC
600 AF
500 AT
3P
65 KAIC
600 AF SS-LSIG
600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS

SWBD-RWPS

PNL-RWPS
480 V, 3 PHASE, 3 WIRE
600 AMPS
65 KASC RMS
3 1200 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS 4 4
SHALL FIELD VERIFY WHERE NEEDED.

AND MAY NOT REFLECT EXACT FIELD CONDITION. CONTRACTOR

1. EXISTING EQUIPMENT INFORMATION ARE FROM RECORD DRAWINGS #

4. EXISTING BREAKERS ARE 100% RATED BREAKER.

3. EXISTING SWITCHBOARD IS WESTINGHOUSE, SERIES POW-R-LINE.

TERMINATE NEW PANEL FEEDER CABLES ON NEW LUGS.

2. INSTALL NEW LUGS ON EXISTING MCC HORIZONTAL BUS AND
NUMBER IS 4713A99H12.

1. EXISTING MCC IS WESTINGHOUSE, SERIES 2100. MCC SERIAL GENERAL NOTES:

KEY NOTES:

P
lotD
ate: 05
-APR
-2023
3:31:28
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1003E01.dgn
JGB

WTP MODIFIED OVERALL ONE-LINE DIAGRAM
95 avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:37:01-07'00'
200

Page 360 of 599 ends

30" 25" 25"
90"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE: 1
2A2B2CVFD-99412 2DRECYCLED
WATER PUMP #2
VFD-99413

RECYCLED
WATER PUMP #3
VFD-99414

RECYCLED
WATER PUMP #4

XFMR-RWPS-L

RWPS LIGHTING

TRANSFORMER
SPACE
SPACE
SPD
MAIN

BREAKER

INCOMING
LINE
2E1A1B1C1D1ESPACE

SPACE SPACE
SPACE
1F1G1H1I1J1KVFD-99415

RECYCLED
WATER PUMP #5
(FUTURE)
2 ABCDE

JIHGFEDCBAK
WATER PUMP #1

RECYCLED
VFD-99411
3/4" = 1'-0"
8660F1003E0611
3/4" = 1'-0"
8660F1003E0611
PQM-99400

METERING
POWER
PlotDate: 05-APR-2023 3:30:09PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 03E02
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1003E02.dgn

SWBD-RWPS ELEVATION
JGB
96 avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:25:38-07'00'
200

Page 361 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
600:5
3 500 AT
3P 3P
TM
3 PHASE
30 KVA

SPD
LR
75 3P
TM
65 KAIC
3 -#1/0
(Ø
)
& 1-#6
(G
)
600 AF
65 KAIC

SS-LSIG

RECYCLED WATER
PUMP #1
VFD-RH
150 AT
150 AF
LR
75 3P
TM
65 KAIC
3 -#1/0
(Ø
)
& 1-#6
(G
)

RECYCLED WATER
PUMP #2
VFD-RH
150 AT
150 AF
LR
75 3P
TM
65 KAIC
3 -#1/0
(Ø
)
& 1-#6
(G
)

RECYCLED WATER
PUMP #3
VFD-RH
150 AT
150 AF
LR
75 3P
TM
65 KAIC
3 -#1/0
(Ø
)
& 1-#6
(G
)

RECYCLED WATER
PUMP #4
VFD-RH
150 AT
150 AF
90 AT
480 V
208/120 V
65 KAIC
3 -#3
(Ø
)
& 1-#8
(G
)
3 -#3
(Ø
), 1-#3
(N
)
& 1-#8
(G
)
RECYCLED WATER P.S.

LIGHTNING PANELBOARD
VFD-99411
PMP-99411
VFD-99412 VFD-99413 VFD-99414
PMP-99412 PMP-99413 PMP-99414 PNL-RWPS-L

XFMR-RWPS-L

MAIN BREAKER

FROM PNL-RWPS
LR
75 3P
TM
150 AT

RECYCLED WATER
PUMP #5
(FUTURE)
VFD-99415
PMP-99415
VFD-RH
150 AF
65 KAIC
SWBD-RWPS, 600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65KASC RMS 2{3
-500KC
M
IL
(Ø
)
& 1-#2/0
(G
)}
SSM
P
lotD
ate: 05
-APR
-2023
3:28:25
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E03
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1003E03.dgn

SWBD-RWPS ONE-LINE DIAGRAM
JGB
avates
1 06N01
1 06N01
1 06N01
1 06N01
1 06N01
97 Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:40:39-07'00'
200

Page 362 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

PED-325
TFR-3E
PED-983
TFR-2E TFR-1E
PED-326

(CITY OF UKIAH)
UTILITY 12KV
TFR-1
SWR12101
~
G
~
G
1 1
1 STANDBY GENERATOR
GEN12151 GEN12151
(FUTURE)
STANDBY GENERATOR 2
1 2 1
SWB22281 SWB22282
SWB31281 SWB31282
SWB40481
SWB70281
SWB40482
SWB70282
SWB50481 SWB50482
MCC12191 MCC12192
MCC-C
MCC-A
MCC-D

SPACE SPACE

PUMPING SUBSTATION

TRICKLING FILTER

SUBSTATION

HEADWORKS

SUBSTATION

AERATION BLOWER

SUBSTATION
DAFT

SUBSTATION

CLARIFIERS

SECONDARY

SUBSTATION

GENERATION
POWER

SPARE SPARE
52-A5 52-A4 52-A3 52-A2

52-A1
52-AT
52-B1 52-B2 52-B3 52-B4 52-B5 52-B6 52-B7
52-M 52-G1 52-G2
TFR-1E
PHASE 1-3 PUMP STATION CAROUSEL PUMP STATION MAINTENANCE BUILDING ANIMAL SHELTER 3 BUILDING

MECHANICAL

FACILITY
AWT

FACILITY

DEWATERING
SLUDGE
SHALL FIELD VERIFY WHERE NEEDED.

AND MAY NOT REFLECT EXACT FIELD CONDITION. CONTRACTOR

2. EXISTING EQUIPMENT INFORMATION ARE FROM RECORD DRAWINGS DEPARTMENT (COUED).

1. ELECTRIC UTILITY COMPANY IS CITY OF UKIAH ELECTRIC
#
COMPLETED BY THE CONTRACTOR.

AFTER INSTALLATION OF NEW UNDERGROUND 12KV CONDUITS IS
12KV CONDUCTORS INSIDE NEW UNDERGROUND 12KV CONDUITS

3. CITY OF UKIAH ELECTRIC DEPARTMENT (COUED) TO INSTALL NEW AND EXISTING 12KV LINE ROUTING.

SITE PLAN DRAWING 01E02 FOR TRF-3E AND PD-983 LOCATIONS, DURATION AND ACCESS FOR THIS SCOPE WITH COUED. REFER TO PEDESTAL PD-983. CONTRACTOR SHALL COORDINATE THE TIMING, EXISTING 12KV CONDUCTORS BETWEEN TRANSFORMER TRF-3E AND

2. CITY OF UKIAH ELECTRIC DEPARTMENT (COUED) TO REMOVE
(COUED).

IS OWNED AND OPERATED BY CITY OF UKIAH ELECTRIC UTILITY

1. EXISTING 12KV UTILITY LINE FOR WASTEWATER TREATMENT PLANT GENERAL NOTES:

KEY NOTES:

P
lotD
ate: 05
-APR
-2023
3:27:02
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E04
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
BLS

ELECTRICAL
8660F10 8660F1003E04.dgn
JGB

ONE-LINE DIAGRAM

WWTP MODIFIED OVERALL
98 avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:40:23-07'00'
200

Page 363 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
#
GENERAL NOTES:

KEY NOTES:
3P
TM
40 LL
LR
VFD-6
3P
MCP
FVNR
40 3P
MCP
FVNR
40 TM
3P
200 AMPS, 480/277 V, 3 PHASE, 4 WIRE, 60 HZ, 65 KASC RMS

EFFLUENT
PUMP NO. 3
3 EFFLUENT
PUMP NO. 2

EFFLUENT
PUMP NO. 1
3 20 AT
? ?
EDR-99101 EDR-99102
TM
2P
20 AT
1 PHASE
1 KVA
480V
120/240V
FIT-99105
VALVE NO. 1

CONTROL
FLOW
VALVE NO. 2

CONTROL
FLOW
METER

VAULT FLOW

METERING
3 PHASE
12KV
480/277V
150 KVA
1 2
1 TRF-3E
(ADMIN BUILDING)
TO PEDESTAL 983
(RECYCLE PUMP STATION)
T2076

TO TRANSFORMER
NO
A
NO
B
3 POLE
200 A

MAIN DISCONNECT SWITCH

MOTOR CONTROL CABINET
5 3 4

TRANSFORMER
6 7
FOR ADDITIONAL DEMOLITION REQUIREMENTS.

REMAIN IN PLACE. REFER TO DRAWING 00D01 GENERAL NOTES

UNDERGROUND AND CONCRETE EMBEDDED CONDUITS SHALL
WHICH ARE MARKED ON THIS DRAWING FOR DEMOLITION.

2. DEMOLISH EXPOSED CONDUIT, AND ALL CABLES FOR CIRCUITS (COUED).

1. ELECTRIC UTILITY IS CITY OF UKIAH ELECTRIC DEPARTMENT

8. SEE DRAWING 03E04 FOR DEMO NOTES.

RECONNECTED TO PNL70271.

7. EXISTING FLOW METER DISCONNECT SWITCH TO BE
MCC70293.

6. EXISTING DISCONNECT SWITCH TO BE RECONNECTED TO
MCC70292, AND REDESIGNED AS A CAROUSEL PUMP.

5. EXISTING PUMP WITH NEW MOTOR TO BE RECONNECTED TO
MCC70291, AND REDESIGNATED AS A CAROUSEL PUMP.

4. EXISTING PUMP WITH NEW MOTOR TO BE RECONNECTED TO
MOTOR REQUIREMENTS.

PUMP. PROTECT PUMP IN PLACE. REFER TO SPEC 11312D FOR

3. REMOVE EXISTING PUMP MOTOR FROM EXISTING EFFLUENT
01140.

PROCEDURE SHOULD COMPLY WITH SPECIFICATION SECTION
POSITION. IF POWER SHUT DOWN IS REQUIRED, THE
(COUED), AND PLACE BOTH A AND B SWITCHES IN OPEN

PLANT OPERATOR AND CITY OF UKIAH ELECTRIC DEPARTMENT
IN PLACE. DEMOLISH SECONDARY CONDUCTORS. VERIFY WITH

2. PROTECT CAROUSEL PUMP STATION EXISTING TRANSFORMER
DEPARTMENT (COUED).

PLANT. IS OWNED AND OPERATED BY CITY OF UKIAH ELECTRIC
8 1. EXISTING 12KV UTILITY LINE FOR WASTEWATER TREATMENT P
lotD
ate: 05
-APR
-2023 1:12:22
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E05
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E05.dgn
JGB

DEMO ONE-LINE DIAGRAM

CAROUSEL PUMP STATION
99 ggraham
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:30:10-07'00'
200

Page 364 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
TM
225 AT
3P
65 KAIC
600 AF
TM
225 AT
3P
65 KAIC
225 AF
150 AT
3P
150 AF
TM
150 AT
3P
65 KAIC
600 AF
TM
65 KAIC
MCC-D
K K
TM
300 AT
3P
65 KAIC
600 AF
300 AT
3P
TM
65 KAIC
400 AF
K
TM
300 AT
3P
65 KAIC
600 AF
400 AT
3P
400 AF TM
65 KAIC
K
MCC-C
400 AT
3P
600 AF TM
65 KAIC 400 AT
3P
600 AF TM
65 KAIC
MCC70293
K K
TM
300 AT 65 KAIC
3P
600 AF
K
TM
300 AT 65 KAIC
3P
600 AF
K
MCC70292
TM
300 AT 65 KAIC
3P
600 AF
K
TM
300 AT 65 KAIC
3P
600 AF
K
MCC70291
1600 AT 65 KAIC
3P
1600 AF SS-LSIG
1600 AT 65 KAIC
3P
1600 AF SS-LSIG

SPD SPD
1600 AT
3P
1600 AF
52-B4
1600 AT
3P
1600 AF
52-A4
SS SS
4000 AT
3P
5000 AF
52-M
SS
2500 AT
3P
3200 AF
52-G1
SS
100 KAIC
100 KAIC 100 KAIC
52-AT
100 KAIC
SWR12101, 5000AMPS, 480V, 3Ø, 4WIRE, 60HZ, 100KAIC
~
G
3 PHASE
480V
1875KVA/1500KW
4 WIRE

0.8 PF
GEN-1
3 PHASE
TFR-1
2500 KVA
12KV
480V

5.75%

UTILITY
SWB70281, 1600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS SWB70282, 1600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS

NC NC NC NO NC NO NC NO NO NO
NC
NC
NC
NC NC
NC
NC
NO
NO
P
lotD
ate: 05
-APR
-2023 1:12:12
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E06
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HR
SMB

ELECTRICAL
SWBD70281 AND SWBD70282

ONE-LINE DIAGRAM
8660F10 8660F1003E06.dgn
GENERAL NOTES:
# KEY NOTES:

COMPLETE ONE-LINE DIAGRAM.

WHERE NEEDED, OR REFER TO OWNER'S RECORD DRAWING FOR
SHOWS SELECTIVE LOADS AND CONNECTIONS. FIELD VERIFY

3. ONE-LINE DIAGRAM FOR THIS EQUIPMENT IS PARTIAL AND ONLY BUILDING.

2. EXISTING SWITCHBOARD IS LOCATED INSIDE DAFT ELECTRICAL BUILDING.

1. EXISTING SWITCH GEAR IS LOCATED INSIDE POWER GENERATION 1 3
2 2
JGB
avates
SHALL FIELD VERIFY WHERE NEEDED.

AND MAY NOT REFLECT EXACT FIELD CONDITION. CONTRACTOR

3. EXISTING EQUIPMENT INFORMATION ARE FROM RECORD DRAWINGS CONTRACTOR SHALL FIELD VERIFY WHERE NEEDED.

DRAWINGS AND MAY NOT REFLECT ACTUAL FIELD INFORMATION.

STATUS (OPEN/CLOSE), AND TRIP SETTINGS ARE FROM RECORD

2. EXISTING BREAKERS TYPE, RATINGS, FRAME SIZES, BREAKER

1. EXISTING SWITCHBOARD IS SQUARE D TYPE QED.
100
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:30:26-07'00'
200

Page 365 of 599 ends

20" 20"
90"
20" 20" 20" 20" 20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
#
GENERAL NOTES:

KEY NOTES:

2. REMOVE AND DISPOSE OF EXISTING MCC BUCKET COVER.

INSIDE MCC BUCKET.

1. REMOVE AND DISPOSE OF EXISTING ELECTRICAL EQUIPMENT
1 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
2 3 4 5 6
1 2
2 1
1 2 2 2
1A- SPACE 2A- SPACE 3A- SPACE 4A- SPACE 5A- FILTER

SURFACE WASH
PUMP
6A- METERING
1C- AWT
PUMP NO. 1
2C- AWT
PUMP NO. 3
3C- AIR WASH
BLOWER NO. 2
4C- FILTER

BACKWASH
PUMP NO. 2
5C- WASHWATER

SLUDGE PUMP
6C- MAIN BREAKER 1
1F- AWT
PUMP NO. 2
2F- AIR WASH
BLOWER NO. 1
3F- FILTER

BACKWASH
PUMP NO. 1
4G- AIR

COMPRESSOR
5E- DP1

DISTRIBUTION
PANEL 1
6H- MAIN BREAKER 2
1I- HWCP-5

HOT WATER
PUMP
2I- SPACE 3JL3JRUH-9

UNIT HEATER

ROLL UP DOOR
4I- WASHWATER

RETURN PUMP
1K- RAPID MIX
PUMP
2K- SPACE 3L- SPACE 4KL4KRXFMR-A
PNL-A

LIGHTING

PANELBOARD
DP1

DISTRIBUTION
PANEL 1
1 1. EXISTING MCC IS WESTINGHOUSE, SERIES 2100.
3/4" = 1'-0"
8660F1003E9621
3/4" = 1'-0"
8660F1003E9621
1 P
lotD
ate: 05
-APR
-2023 1:12:30
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E09
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E09.dgn

MCC-C DEMO ELEVATION
JGB
101
bshepard
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:23:53-07'00'
200

Page 366 of 599 ends

20" 20"
90"
20" 20" 20" 20" 20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
1 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
2 3 4 5 6
#
GENERAL NOTES:

KEY NOTES:
1 1
2 1 1 1 1
1 3
NOT COMPLETELY FILL SPACE OF REMOVED UNIT.

3. PROVIDE COVERS FOR MCC AS NEEDED WHERE NEW UNITS DO
ACTUAL EQUIPMENT DIMENSIONS IN THE FIELD.

2. EXISTING MCC OVERALL DIMENSIONS MAY NOT REFLECT THE

1. EXISTING MCC IS WESTINGHOUSE, SERIES 2100.
3/4" = 1'-0"
8660F1003E0621
3/4" = 1'-0"
8660F1003E0621
ELEVATION TABLE.

3. RELABEL EXISTING MCC BUCKET ACCORDING TO MCC

2. PROVIDE NEW COVER.

CONTROL SCHEMATICS, AND SPECIFICATIONS.

NECESSARY EQUIPMENT ACCORDING TO ONE-LINE DIAGRAMS,

1. PROVIDE NEW BREAKER, MOTOR STARTERS AND ALL THE
1 1
1A- FAN-85109

AIR WASH
BLOWER
FAN NO. 1
2A- FAN-85110

AIR WASH
BLOWER
FAN NO. 2
3A- FAN-85111

AIR WASH
BLOWER
FAN NO. 3
4A- DP2

DISTRIBUTION
PANEL 2
5A- FILTER

SURFACE WASH
PUMP
6A- METERING
1C- AWT
PUMP NO. 1
2C- AWT
PUMP NO. 3
3C- BLO-85107

AIR WASH
BLOWER NO. 2
4C- FILTER

BACKWASH
PUMP NO. 2
5C- PMP-87134

BACKWASH

CHLORINE

SAMPLE PUMP
6C- MAIN BREAKER
A
1F- AWT
PUMP NO. 2
2F- BLO-85106

AIR WASH
BLOWER NO. 1
3F- FILTER

BACKWASH
PUMP NO. 1
4G- AIR

COMPRESSOR
5E- DP1

DISTRIBUTION
PANEL 1
6H- MAIN BREAKER
B
1I- HWCP-5

HOT WATER
PUMP
2I- BLO-85108

AIR WASH
BLOWER NO. 3
3JL3JRUH-9

UNIT HEATER
________________

ROLL UP DOOR
4I- SPARE NEMA 2
1K- PMP-85104

RAPID MIX
PUMP
2L- SPACE 3L- SPACE 4KL4KR
-
XFMR-A
PNL-A

LIGHTING

PANELBOARD
________________
DP1

DISTRIBUTION
PANEL 1

BREAKER
P
lotD
ate: 05
-APR
-2023 1:11:30
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E10
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E10.dgn

ELEVATION

MCC-C MODIFIED
JGB
102
bshepard
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:24:59-07'00'
200

Page 367 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
3P
MCP
FVNR
SLUDGE
65 KAIC
SIZE 1
15 AC

SECONDARY
PUMP NO. 1
5 3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 1
3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 2
3P
MCP
FVNR
3/4
65 KAIC
SIZE 1
3 AC

HOT WATER
PUMP
HWCP-5
3P
MCP
FVNR

1.5 65 KAIC
SIZE 1
7 AC

RAPID MIX
PUMP
5 3P
MCP

7.5 3
-#12
(Ø
)
& 1-#12
(G
)
15 AC 65 KAIC

RAPID MIX
PUMP
PMP-85104
3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 3
3P
MCP
50 RVSS
100 AC 65 KAIC
BLOWER NO. 1
3P
MCP
50 RVSS
100 AC 65 KAIC
BLOWER NO. 2
3P
MCP
60 FILTER
65 KAIC
SIZE 4
100 AC
PUMP NO. 1

BACKWASH
3P
TM
15 AT 65 KAIC

UNIT HEATER
UH-9
KW
3 3P
TM
15 AT 65 KAIC

ROLL UP DOOR
HP
2 3P
MCP
60 FILTER
65 KAIC
SIZE 4
100 AC
PUMP NO. 2

BACKWASH
3P
MCP
FVNR
65 KAIC
SIZE 2
15 AC
AIR

COMPRESSOR
5 3P
MCP
FVNR
65 KAIC
SIZE 2
30 AC
3P
TM
30 KVA

50 AT 65 KAIC
XFMR-A
208/120 V
480 V

LIGHTING

PANELBOARD
PNL-A
3 PH
TM
3P
60 AT 65 KAIC
DP1

DISTRIBUTION
PANEL 1
3P
MCP
FVNR
15 FILTER
65 KAIC
SIZE 2
30 AC
PUMP

SURFACE WASH
3P
MCP
FVNR
65 KAIC
SIZE 2
30 AC
3P
TM
300 AT 65 KAIC
400 AF
MCC-C, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS CON
TINU
ED
AT
UPPER
R
IGH
T
CON
TINU
ED
AT
LO
W

ER LEFT
# KEY NOTES:
1 1 1
REMAIN IN PLACE.

UNDERGROUND AND CONCRETE EMBEDDED CONDUITS SHALL
WHICH ARE MARKED ON THIS DRAWING FOR DEMOLITION.

1. DEMOLISH EXPOSED CONDUITS, AND ALL CABLES FOR CIRCUITS 3P
TM
400 AT 65 KAIC
400 AF
SPD
MAIN BREAKER 1 MAIN BREAKER 2
3P K K
TM
65 KAIC
DP2

DISTRIBUTION
PANEL 2
CON
TINU
ED ON
N
EXT
S
HEET
06N05
6 06N06
6 06N06
6 06N06

SPARE SPARE

AIR WASH AIR WASH
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 1

AIR WASH
50 AC
BLO-85106
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 3

AIR WASH
50 AC
BLO-85108
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 2

AIR WASH
50 AC
BLO-85107
100 AT
3 -#2
(Ø
)
& 1-#8
(G
)
P
lotD
ate: 05
-APR
-2023 1:11:46
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E11
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E11.dgn

MCC-C MODIFIED
ONE-LINE DIAGRAM 1
JGB
103
bshepard
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:33:45-07'00'
200

Page 368 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®

CONTINUED ON PREVIOUS SHEET
3P
MCP
1/2
3-#12(Ø)& 1-#12(G)
3 AC 65 KAIC
FAN-85109
FVNR
SIZE 1
FAN NO. 1
3P
MCP
1/2
3-#12(Ø)& 1-#12(G)
3 AC 65 KAIC
FAN-85110
FVNR
SIZE 1
FAN NO. 2
3P
MCP
1/2
3-#12(Ø)& 1-#12(G)
3 AC 65 KAIC
FAN-85111
FVNR
SIZE 1
FAN NO. 3
MCC-C, 600 AMPS, 480 V, 3 Ø, 3 WIRE, 60HZ, 65KASC RMS

AIR WASH BLOWER AIR WASH BLOWER AIR WASH BLOWER
3P
MCP
1/2
3-#10(Ø)& 1-#12(G)
3 AC 65 KAIC
PMP-87134
FVNR
SIZE 1

BACKWASH

CHLORINE SAMPLE PUMP
PlotDate: 05-APR-2023 1:12:34PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 03E12
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E12.dgn

MCC-C MODIFIED
ONE-LINE DIAGRAM 2
JGB
104
ggraham
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:30:42-07'00'
200

Page 369 of 599 ends

20"
90"
20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
5 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
#
GENERAL NOTES:

KEY NOTES:

1. EXISTING MCC IS SQUARE D MODEL 6.

2. PROVIDE NEW COVER.

SCHEMATICS, AND SPECIFICATIONS.

EQUIPMENT ACCORDING TO ONE-LINE DIAGRAMS, CONTROL

1. PROVIDE NEW BREAKER, DRIVES AND ALL THE NECESSARY
3/4" = 1'-0"
8660F1003E0622
3/4" = 1'-0"
8660F1003E0622
5A- SPACE
5C- GDR75112
SLUDGE

GRINDER
DIGESTER 1
5D- P97101

DRAINAGE
PUMP 1
5E- PMP-89100

CAROUSEL
PUMP NO. 1
5F- FV-60100
DCL

STRUCTURE
VALVE 1
5G- FV-60102
DCL

STRUCTURE
VALVE 2
5H- SPACE
5J- SPACE
P
lotD
ate: 05
-APR
-2023 1:11:38
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E18
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1003E18.dgn
MCC70291 PARTIAL ELEVATION
2 1
JGB
2 ggraham
105
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:03-07'00'
200

Page 370 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
CON
TINU
ED
AT
LO
W

ER LEFT
CON
TINU
ED
AT
UPPER
R
IGH
T
3P
TM
10 20 AT 65 KAIC

DAFT AIR
COMPRESSOR 1
LCP70201
HP
3P
MCP
FVNR
1/2
SAMPLE
PUMP 1
65 KAIC
SIZE 1
3 AC

CHLORINE

RESIDUAL
P60211
3P
MCP
FVNR
40 PUMP 1
65 KAIC
SIZE 3
100 AC

PRESSURIZATION
P70221
3P
MCP
FVNR
65 KAIC
SIZE 1
15 AC
DIGESTER 1
PUMP

CIRCULATION
P75111
5 3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC

RECLAIMED
FEED PUMP 1

WATER FILTER
P80111
3P
TM
UNIT 1

POLYMER
20 AT 65 KAIC

BLENDING
PNL70251
AMP
1 3P
TM

GRINDER
SLUDGE
15 AT 65 KAIC
DIGESTER 1
GDR75112
HP
3 SPD
3 MCC70291, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS SSM
3 SSM
SWB70281
MLO
SWB70282
MLO
3P
TM
FVNR

1.5 SLUDGE
DAFT 1
15 AT 65 KAIC
SIZE 1
COL70121B

COLLECTOR
3P
MCP

7.5 15 AT 65 KAIC
MX75101
DIGESTER 1
MIXER

7.5 3P
TM
VFD
20 AT 65 KAIC
P70131

THICKENED
SLUDGE
PUMP 1
VFD70131
3P
TM
35 AT 65 KAIC
HP
20 P97101

DRAINAGE
PUMP 1
3 PHASE
15 KVA
TM
3P

480V
208/120V
45 AT 65 KAIC
XFMR70271 PNL70271
SPARE
SIZE 1
FVNR
MCP
3P
15 AT 65 KAIC
SPARE
TM
3P
20 AT 65 KAIC
LL
40 3P
TM
80 AT 65 KAIC

CAROUSEL
VFD-89100
PMP-89100
PUMP NO. 1
VFD-6
VFD
DV/DT
3P
TM
VALVE 2
3 -#10
(Ø
)
& 1-#10
(G
)
3 -#10
(Ø
)
& 1-#10
(G
)
15 AT 65 KAIC
5 HP
FV-60102

DCL STRUCTURE
3P
TM
VALVE 1
3 -#10
(Ø
)
& 1-#10
(G
)
3 -#10
(Ø
)
& 1-#10
(G
)
15 AT 65 KAIC
5 HP
FV-60100

DCL STRUCTURE
VFD-6
3/4
3P
15 AT 65 KAIC
TM
COL70121A
DAFT 1 FLOAT

COLLECTOR
3 -#6
(Ø
)
& 1-#8
(G
)
[3
-#4
(Ø
)
&
INTEG
R
AL
(G)]:VFD

1. EXISTING MCC IS SQUARE D MODEL 6.
#
H040S2BLG.

CORPORATION, MODEL# BF48A, AND CATALOG#:

AND 16262. EXISTING MOTOR IS MADE BY NIDEC MOTOR
MANUFACTURER, AND SPECIFICATION SECTIONS 16222

SHALL BE COORDINATED WITH THE EXISTING PUMP
WITH NEW VFD DUTY RATED MOTOR. MOTOR SELECTION

1. REPLACE EXISTING MOTOR FOR THE EXISTING PUMP
GENERAL NOTES:

KEY NOTES:
1 P
lotD
ate: 05
-APR
-2023 1:10:49
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E19
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
MCC70291 ONE-LINE DIAGRAM
8660F10 8660F1003E19.dgn
3 06N03
JGB
avates
106
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:37:54-07'00'
200

Page 371 of 599 ends

20"
90"
20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
6 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
#
GENERAL NOTES:

KEY NOTES:

1. EXISTING MCC IS SQUARE D MODEL 6.
1 SPECIFICATIONS.

ACCORDING TO ONE-LINE DIAGRAMS, CONTROL SCHEMATICS, AND

1. PROVIDE NEW BREAKER AND ALL THE NECESSARY EQUIPMENT
6A- POLYMER
BLENDING UNIT 2
PNL70272
6B- 20A SPARE

BREAKER
6C- LCP70202
DAFT AIR COMP 2
6D- SPARE
STARTER - SIZE 1
6F- GDR75122
DIGESTER 2

SLUDGE GRINDER
6G- PMP-89101
CAROUSEL PUMP NO. 2
6H- SPACE
6J- SWB70282
3/4" = 1'-0"
8660F1003E0623
3/4" = 1'-0"
8660F1003E0623
P
lotD
ate: 05
-APR
-2023
3:23:29
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E20
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1003E20.dgn
MCC70292 PARTIAL ELEVATION
JGB
107
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:40:09-07'00'
200

Page 372 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
CON
TINU
ED
AT
LO
W

ER LEFT
CON
TINU
ED
AT
UPPER
R
IGH
T
MLO
MLO
3P
MCP
FVNR

1.5 SLUDGE
DAFT 2
65 KAIC
SIZE 1
7 AC

COLLECTOR
COL70122B
3P
TM
10 20 AT 65 KAIC

DAFT AIR
COMPRESSOR 2
LCP70202
HP
3P
MCP
FVNR
1/2
SODIUM
65 KAIC
SIZE 1
3 AC
UNIT

INDUCTION

HYPOCHLORITE
MME60202
3P
MCP
FVNR
1/2
SODIUM
65 KAIC
SIZE 1
3 AC
UNIT

INDUCTION

BISULFITE
MME60401
3P
TM
UNIT 2

POLYMER
15 AT 65 KAIC

BLENDING
MME70252
HP
1 3P
MCP
FVNR
1/2
SAMPLE
PUMP 2
65 KAIC
SIZE 1
3 AC

CHLORINE

RESIDUAL
P60213
3P
MCP
FVNR
40 PUMP 2
65 KAIC
SIZE 3
100 AC

PRESSURIZATION
P70222
3P
MCP
FVNR

7.5 65 KAIC
SIZE 1
15 AC
DIGESTER 2
PUMP

CIRCULATION
P75121
3P
TM
SLUDGE

GRINDER
15 AT 65 KAIC
DIGESTER 2
PNL75122
HP
3 SPD
SSM
3 SWB70281
SSM
3 SWB70282
MCC70292, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC

RECLAIMED
FEED PUMP 2

WATER FILTER
P80112
VFD-6
LL
40 3P
TM
65 KAIC

CAROUSEL
VFD-89101
80 AT
PMP-89101
3P
TM

7.5 20 AT 65 KAIC
MX75102
DIGESTER 2
MIXER

7.5 3P
TM
20 AT 65 KAIC

THICKENED
SLUDGE
PUMP 2
P70132
DV/DT
3 PHASE
15 KVA
TM
3P

480 V
120/2080 V
45 AT 65 KAIC
XFMR70272 PNL-70272
VFD
VFD
SPARE
TM
3P
20 AT 65 KAIC
SPARE
SIZE 1
FVNR
MCP
3P
15 AC 65 KAIC
[3
-#4
(Ø
)
&
INTEG
R
AL
(G)]:VFD
3 -#6
(Ø
)
& 1-#8
(G
)
HP
3P
TM
COL70122A
DAFT 2 FLOAT

COLLECTOR
VFD

1. EXISTING MCC IS SQUARE D MODEL 6.
#
H040S2BLG.

CORPORATION, MODEL# BF48A, AND CATALOG#:

AND 16262. EXISTING MOTOR IS MADE BY NIDEC MOTOR
MANUFACTURER, AND SPECIFICATION SECTIONS 16222

SHALL BE COORDINATED WITH THE EXISTING PUMP
WITH NEW VFD DUTY RATED MOTOR. MOTOR SELECTION

1. REPLACE EXISTING MOTOR FOR THE EXISTING PUMP
GENERAL NOTES:

KEY NOTES:
1 3
06N03
PUMP NO. 2

P
lotD
ate: 05
-APR
-2023 1:11:28
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E21
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
MCC70292 ONE-LINE DIAGRAM
8660F10 8660F1003E21.dgn
JGB
108
ggraham
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:34:59-07'00'
200

Page 373 of 599 ends

20"
90"
20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
7 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
#
GENERAL NOTES:

KEY NOTES:

1. EXISTING MCC IS SQUARE D MODEL 6.

2. PROVIDE NEW COVER.

ACCORDING TO SINGLE LINE DIAGRAMS AND SPECIFICATIONS.

1. PROVIDE NEW BREAKER AND ALL THE NECESSARY EQUIPMENT
1 2
7A- SPACE
7B- 30A SPARE

BREAKER
7C- UH70244
DAFT EQUIP. ROOM

UNIT HEATER
7D- EDR-99101
EDR-99102

FLOW CONTROL
VALVES NO. 1 AND NO. 2
7E- PMP-89102
CAROUSEL PUMP NO. 3
7F- PMP-91100
PAU PUMP NO. 1
7G- SPACE
7I- METERING
7J- 600A MLO
3/4" = 1'-0"
8660F1003E0624
3/4" = 1'-0"
8660F1003E0624
P
lotD
ate: 05
-APR
-2023
3:20:02
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E22
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1003E22.dgn
MCC70293 PARTIAL ELEVATION
JGB
109
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:16-07'00'
200

Page 374 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
CON
TINU
ED
AT
LO
W

ER LEFT
CON
TINU
ED
AT
UPPER
R
IGH
T
MLO
MLO
SSM
3 SWB70281
SSM
3 SWB70282
3P
TM
10 20 AT 65 KAIC
DAFT
UNIT

HANDLING

BUILDING AIR
AHU70246
KW
3P
TM

1.5 DAFT 3
SLUDGE
FUTURE
15 AT 65 KAIC

COLLECTOR
HP
3P
TM
10 20 AT 65 KAIC

DAFT AIR
COMPRESSOR 3
LCP70203
HP
3P
MCP
FVNR
1/2
UNIT 1
SODIUM
65 KAIC
SIZE 1
3 AC

INDUCTION

HYPOCHLORITE
MME60201
3P
MCP
FVNR
1/2
SAMPLE
PUMP 4
65 KAIC
SIZE 1
3 AC

CHLORINE

RESIDUAL
P60411
3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC

RECLAIMED
FEED PUMP 3

WATER FILTER
P80113
3P
TM

POLYMER
UNIT 3
FUTURE
15 AT 65 KAIC

BLENDING
PLC70299
HP
1 SPD
TM
3P
65 KAIC
2 STORM DRAIN
PUMP 1
MCC70293, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3P
TM
3/4
FUTURE
15 AT 65 KAIC
DAFT 3 FLOAT

COLLECTOR
VCP-SD
2 STORM DRAIN
PUMP 2
3P
MCP
FVNR
20 BLOWER
50 AC 65 KAIC
SIZE 2

CHLORINATION

AERATION
B60221
3P
MCP
FVNR
1/2
SAMPLE
3 AC 65 KAIC
SIZE 1

RESIDUAL
P60215

CHLORINE
PUMP 3
PUMP

7.5 3P
TM
15 AT 65 KAIC

THICKENED
SLUDGE
VFD
P70133
3P
MCP
FVNR
40 65 KAIC
SIZE 3
P70223
100 AC

PRESSURIZATION
PUMP 3
3P
TM
20 PUMP 2
35 AT 65 KAIC
HP
P97102
3P
TM
15 AT 65 KAIC
KVA
5 PNL80114

RECLAIMED

WATER FILTER

CONTROL
PANEL
VFD-6
LL
10 3P
TM
25 AT 65 KAIC
3 -#10
(Ø
)
& 1-#10
(G
)
DV/DT
PMP-91100
VFD-91100
PAU PUMP NO. 1
VFD-6
LL
40 3P
TM
65 KAIC
DV/DT
PMP-89102
VFD-89102

CAROUSEL
3P
TM
20 AT 65 KAIC
RIVER

DISCHARGE

CONTROL VALVE
3 PHASE
15 KVA
TM
3P

480 V
120/208 V
45 AT 65 KAIC
XFMR70273 PNL70273
VFD

DRAINAGE
80 AT
TM
3P
HP HP
VALVE NO. 1

CONTROL
FLOW
EDR-99101
VALVE NO. 2

CONTROL
FLOW
EDR-99102
15 AT 65 KAIC
[3
-#8
(Ø
)
&
INTEG
R
AL
(G)]:VFD
[3
-#4
(Ø
)
&
INTEG
R
AL
(G)]:VFD
3 -#6
(Ø
)
& 1-#8
(G
)
3 -#10
(Ø
)
& 1-#10
(G
)

1. EXISTING MCC IS SQUARE D MODEL 6.

GENERAL NOTES:
4 06N04
3 06N04
PUMP NO. 3
P
lotD
ate: 05
-APR
-2023 1:11:18
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E23
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
MCC70293 ONE-LINE DIAGRAM
8660F10 8660F1003E23.dgn
bshepard
JGB
110
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:30-07'00'
200

Page 375 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
PANEL PNL-RWPS-L 3/6/2023
LIRWPS
LOCATION: RECYCLED WATER PUMP STATION ELECTRICAL BUILDING NEMA: 1 PH A WEIGHTED VA 6195 VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 4035
PHASE & WIRE: 3 PH 4W MTG. SURFACE PH C WEIGHTED VA 7613 INTERRUPT: 10 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 22838
MAIN RATING: 125 AF 100 AT PANEL AMPS 63.4

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C RECYCLED WATER ELECTRICAL BUILDING LIGHTING 280 20A-1P 1 A 2 20A-1P 720 RECYCLED WATER ELECTRICAL BUILDING RECEPTACLES I I RECYCLED WATER ELECTRICAL BUILDING RECEPTACLES 360 20A-1P 3 B 4 20A-1P 340 RECYCLED WATER PUMP STATION LIGHTING C I RECYCLED WATER PUMP STATION RECEPTACLES 900 20A-1P 5 C 6 35A-2P 2600 CU-99422 - OUTDOOR CONDENSER UNIT NO. 2 C C PCM-99400 POWER FEED NO. 1 1500 20A-1P 7 A 8 2600 FCU-99422 C S PCM-99400 POWER FEED NO. 2 1500 20A-1P 9 B 10 35A-2P 2600 CU-99421 - OUTDOOR CONDENSER UNIT NO. 1 C C RECYCLED WATER STORAGE LIGHTING 170 20A-1P 11 C 12 2600 FCU-99421 C SPARE 20A-1P 13 A 14 20A-1P SPARE
SPARE 20A-1P 15 B 16 20A-1P SPARE
SPARE 20A-1P 17 C 18 20A-1P SPARE
SPARE 20A-1P 19 A 20 20A-1P SPARE
SPARE 20A-1P 21 B 22 20A-1P SPARE
SPARE 20A-1P 23 C 24 20A-1P SPARE
SPARE 20A-1P 25 A 26 20A-1P SPARE
SPARE 20A-1P 27 B 28 20A-1P SPARE
SPARE 20A-1P 29 C 30 20A-1P SPARE
PANEL DP2 3/30/2023
LOCATION: ADVANCE WATER TREATMENT (AWT) NEMA: 1 PH A WEIGHTED VA 13334 VOLTS: 480 FEED: TOP PH B WEIGHTED VA 13334
PHASE & WIRE: 3 PH 3W MTG. SURFACE PH C WEIGHTED VA 13334 INTERRUPT: 65 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 40002
MAIN RATING: 100 AF 100 AT PANEL AMPS 48.1

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S I 1469 1 A 2 1719 I
I FCV-85211 & FV-85212 & FV-85214 - FILTER 1 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 3 B 4 15A-3P 1719 FV-85217 & FCV-85218 & FV-85219 - FILTER 1 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 5 C 6 1719 I
I 1469 7 A 8 1719 I
I FCV-85221 & FV-85222 & FV-85224 - FILTER 2 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 9 B 10 15A-3P 1719 FV-85227 & FCV-85228 & FV-85229 - FILTER 2 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 11 C 12 1719 I
I 1469 13 A 14 1719 I
I FCV-85231 & FV-85232 & FV-85234 - FILTER 3 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 15 B 16 15A-3P 1719 FV-85237 & FCV-85238 & FV-85239 - FILTER 3 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 17 C 18 1719 I
I 1469 19 A 20 1719 I
I FCV-85241 & FV-85242 & FV-85244 - FILTER 4 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 21 B 22 15A-3P 1719 FV-85247 & FCV-85248 & FV-85249 - FILTER 4 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 23 C 24 1719 I
I 582 25 A 26
I FV-87130 - HIGH RATE BACKWASH VALVE 582 15A-3P 27 B 28 15A-3P SPARE I 582 29 C 30
31 A 32
SPARE 15A-3P 33 B 34 15A-3P SPARE
35 C 36
37 A 38
SPARE 15A-3P 39 B 40 15A-3P SPARE
41 C 42
P
lotD
ate: 05
-APR
-2023
3:18:03
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
04E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1004E01.dgn
JGB
PANELBOARD SCHEDULES 1
avates
111
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:21:49-07'00'
200

Page 376 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
# KEY NOTES:
3 2
4 1
1 1

4. EXISTING PANELBOARD IS SQUARE D TYPE NQOD.

3. EXISTING PANELBOARD IS SQUARE D TYPE NQOD.

ACCORDINGLY.

CHANGES TO PANEL CIRCUIT SCHEDULE IN THE FIELD

2. PROVIDE NEW CIRCUIT FOR THE NEW LOADS. REFLECT
PROVIDED PANEL BOARD SCHEDULE.

RELOCATE CIRCUIT BREAKERS AS NEEDED TO MATCH

1. RENAME THIS CIRCUIT IN THE PANEL CIRCUIT SCHEDULE.

PA PNL-A 3/9/2023
LOCATION: AWT BUILDING NEMA: 1 PH A WEIGHTED VA 8863
VOLTS: 208/120 FEED: TOP PH B WEIGHTED VA 9933
PHASE & WIRE: 3 PH 4W MTG. SURFACE PH C WEIGHTED VA 9496 INTERRUPT: 10 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 29798
MAIN RATING: 100 AF 100 AT PANEL AMPS 82.7

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C LTS-CONTROL/BLOWER ROOM 500 20A-1P 1 A 2 20A-1P 700 RCPT-CONTROL/BLOWER ROOM I C LTS-CHEMICAL FEED ROOM 1000 20A-1P 3 B 4 20A-1P 800 RCPT-CHEMICAL FEED ROOM I C LTS-AWT CLARIFIER/FILTER 1000 20A-1P 5 C 6 20A-1P 800 RCPT - AWT CLARIFIER/FILTER I C LTS-EXTERIOR 300 20A-1P 7 A 8 20A-1P 500 RCPT - AWT CLARIFIER/FILTER I C EF-5 CHEMICAL FEED 670 20A-1P 9 B 10 20A-1P 450 UH-6, UH-7, UH-8 C C EF-6 CHEMICAL FEED 670 20A-1P 11 C 12 20A-1P SPARE
C EF-7 CONTROL ROOM 670 20A-1P 13 A 14 15A-1P 1000 EWH-1 C C EF-8 BLOWER ROOM 670 20A-1P 15 B 16 20A-1P 1100 COAGULANT AID POLYMER FEEDER #1 C C AWT BUILDING CONTROL PANEL 1000 20A-1P 17 C 18 20A-1P 1100 COAGULANT AID POLYMER FEEDER #2 S C CAUSTIC LEAK PANEL 500 20A-1P 19 A 20 20A-1P 830 FILTER AID POLYMER FEEDER C C COAGULANT LEAK PANEL 500 20A-1P 21 B 22 20A-1P 1186 VCP-85183 - COAGULANT FEED CONTROL PANEL NO. 3 C C AIT-108/ AIT-109 200 20A-1P 23 C 24 20A-1P 1186 VCP-85182 - COAGULANT FEED CONTROL PANEL NO. 2 S C AIT-110/ AIT-111 200 20A-1P 25 A 26 20A-1P 1186 VCP-85181 - COAGULANT FEED CONTROL PANEL NO. 1 S SPARE 20A-1P 27 B 28 20A-1P 1100 CAUSTIC FEED PUMP #2 S C VCP-3 - AWT CLARIFIER/FILTER CONTROL PANEL 1000 20A-1P 29 C 30 20A-1P 1100 CAUSTIC FEED PUMP #1 C I LTG & RCPT AWT & BACKWASH PS 500 20A-1P 31 A 32 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 1 1130 20A-1P 33 B 34 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 2 1587 20A-1P 35 C 36 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 3 1130 20A-1P 37 A 38 20A-1P 300 HEAT TAPE C SPARE 20A-1P 39 B 40 20A-1P 300 HEAT TAPE C
SPARE 20A-1P 41 C 42 15A-1P 100 BINKLEY ALARM C
PANEL PNL70271 4/4/2023
LOCATION: DAFT BUILDING - MCC70271 NEMA: 1 PH A WEIGHTED VA 4568 VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 4173
PHASE & WIRE: 3 PH 4W MTG. MCC PH C WEIGHTED VA 3721
INTERRUPT: 10 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 13703
MAIN RATING: 100 AF 60 AT PANEL AMPS 38.0

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C P60321 (PNL60321) 600 20A-1P 1 A 2 20A-1P 100 FIT7521 C C P60341 (PNL60341) 100 20A-1P 3 B 4 20A-1P 100 FIT7025 C C LTG-DIGESTERS 173 20A-1P 5 C 6 20A-1P 100 FIT7041 C
C RECPT-DIGESTERS 180 20A-1P 7 A 8 20A-1P 248 DAFT DECK LIGHTNING C C FIT6031 100 20A-1P 9 B 10 20A-1P 850 DAFT TANK LIGHTNING C C LIT6011 100 20A-1P 11 C 12 20A-1P 360 DAFT TANK RECEPTACLE I C PNL60301 600 20A-1P 13 A 14 20A-1P 650 DAFT BLDG INTERIOR LTG C C PNL60331 600 20A-1P 15 B 16 20A-1P 650 DAFT BLDG INTERIOR LTG C C FIT8001 100 20A-1P 17 C 18 20A-1P 720 DAFT BLDG INTERIOR RECEP I C FIT8002 100 20A-1P 19 A 20 20A-1P 720 DAFT BLDG INTERIOR RECEP I C MME60212 (AIT6004) 100 20A-1P 21 B 22 20A-1P 500 RESTROOM MINI WATER HTR C C NJB-60001 - ETHERNET SWITCH 100 15A-1P 23 C 24 20A-1P 100 LCP70272 C C FIT-99105 - METERING VAULT FLOW METER 100 20A-1P 25 A 26 20A-1P 500 PNL70241 C I CAROUSEL AND PAU RECEPTACLES 360 20A-1P 27 B 28 20A-1P 50 CV70261 C C CAROUSEL AND PAU LIGHTING 360 20A-1P 29 C 30 20A-1P 1080 PLC70299 C P
lotD
ate: 05
-APR
-2023
3:12:20
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
04E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1004E02.dgn
JGB
PANELBOARD SCHEDULES 2
112
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:39:21-07'00'
200

Page 377 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
DISCONNECT SCHEDULE 11/17/2022

TAG VOLTAGE POLES AMPS NEMA TYPE TYPE HORSEPOWER FUSE SIZE BREAKER AF/AT ACCESSORIES B 600 VAC 3P 30A 4X-SS NON-FUSED
E 600 VAC 3P 60A 4X-SS NON-FUSED 4
S 600 VAC 3P 200A 4X-SS NON-FUSED 4
T 600 VAC 2P 60A 4X-SS NON-FUSED
ACCESSORIES 1="B" TYPE ELECTRICAL INTERLOCK FOR POSITION INDICATION 2=INSULATED GROUNDABLE NEUTRAL KIT
3=DRAIN AND BREATHER KIT WHEN OUTDOORS
4=EARLY BREAK AUXILIARY CONTACT
LUMINAIRE SCHEDULE 3/8/2023

ITEM DESCRIPTION MOUNTING LAMP LUMINAIRE SPECIFICATIONS

METHOD QUANTITY TYPE MANUFACTURER CATALOG VOLTS VA
A

AUTOBAHN SERIES ATBM POLE LIGHT, ROADWAY TYPE III DISTRIBUTION FOUR-BOLT MAST ARM MOUNT FOR 1.25 TO 2 INCH OD POLE
w/ROUND TAPERED POLE WITH MOUNTING ARM

PROVIDE MOUNTING FOR TWO HEADS/ARMS ON A SINGLE POLE WHERE SHOWN COLOR TO MATCH EXISTING LIGHT POLES AND ANODIZED ALUMINUM, 12'-0" HIGH, 4" DIA 7 PIN INTEGRAL PHOTOCELL SENSOR AND CONTROL WITH DIMMABLE DRIVE

PROVIDE EMBEDDED GFCI RECEPTACLE WITH WEATHER PROOFING COVER WHERE SHOWN POLE
MOUNT
N/A
LED
4000 CCT
10,675 LUMENS

AMERICAN

ELECTRIC

LIGHTING
ATBM P10 MVOLT R3 4B UMR-XX P7 120 81
B

SEALED, AND GASKETED LED LUMINAIRE, CLEAR POLYCARBONATE LENS 80 CRI, SUITABLE FOR WET LOCATIONS, w/ HIGH EFFICIENCY LEDs FOR AMBIENT TEMPERATURES -29 TO 40 DEG C, L80 AT 75,000 HOURS

CALIFORNIA ENERGY CODE COMPLIANT BUILT-IN EMERGENCY BACKUP WHERE SHOWN

CEILING MOUNT

OR SUSPENDED

AS NEEDED
N/A
LED
4000K CCT
6,643 LUMENS
HOLOPHANE EVT4 6000LM PCL WD MVOLT 40K 80 120 71
C

DELEON TL SINGLE FACE EXIT SIGN, UL WET LOCATION LISTED, SELF DIAGNOSTICS AMBIENT TEMPERATURES -40 TO 45 DEG C
DUAL VOLTAGE 120/277 w/GREEN EXIT LETTERS

SELF-CONTAINED, SEALED MAINTENANCE FREE NICKEL CADMIUM BATTERIES WALL

OR CEILING
MOUNT
N/A LED HOLOPHANE LNTLL NC W SG S 120 4.8
D

BUILDING-MOUNTED LUMINAIRE WITH ALUMINUM HOUSING SEALED AGAINST

MOISTURE AND ENVIRONMENTAL CONTAMINANTS
70 CRI, TYPE IV LIGHT DISTRIBUTION, HIGH EFFICIENCY LEDs w/ MOTION/AMBIENT LIGHT SENSOR, DARK BRONZE WITH BATTERY PACK

WALL MOUNT N/A
LED
4000K CCT
2,000 LUMENS

LITHONIA
MRW LED P1 40K SR4 MVOLT PIR DDBXD
E20WC
120 28.8
ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE 4/3/2023
TAG NO

MINIMUM INTERIOR

DIMENSIONS (INCHES) CONSTRUCTION

TYPICAL
DETAIL

SURFACE

LOADING

COMMENTS

WIDTH LENGTH DEPTH
COUED-4 60 60 48 60" ROUND PRECAST ROADWAY COUED "504" CUSTOM CONSTRUCTION FOR MV VAULT HH-1 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-2 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-3 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-4 52 52 62 PRECAST CONCRETE EM056 SIDEWALK
HH-10 52 52 62 PRECAST CONCRETE EM056 ROADWAY
HH-11 44 44 54 PRECAST CONCRETE EM056 ROADWAY
MH-12 60 60 84 PRECAST CONCRETE EM062 ROADWAY
HH-13 44 44 54 PRECAST CONCRETE EM056 ROADWAY
HH-20 48 48 54 PRECAST CONCRETE EM056 ROADWAY
HH-21 48 48 54 PRECAST CONCRETE EM056 ROADWAY
NOTES:

1. SEE SPECIFICATION 02581 FOR PRECAST ELECTRICAL HANDHOLES AND MANHOLES.

2. ALTERNATES: PROVIDE PER TYPICAL DETAIL EM062 IF INDICATED UNDER "COMMENTS".

P
lotD
ate: 05
-APR
-2023 1:21:58
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
05E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1005E01.dgn
JGB
# KEY NOTES:

EFFICIENCY STANDARD SECTION 130.0(c).

1. LUMINAIRE SHALL BE FACTORY LABELED PER 2019 BUILDING 1 AND DISCONNECT SCHEDULES

LUMINAIRE, MANHOLE/HANDHOLE,
avates
113
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:43-07'00'
200

Page 378 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 3:12:41PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 05E02
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1005E02.dgn
TITLE 24 COMPLIANCE SHEETS 1
114
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:08-07'00'
200

Page 379 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 2:35:49PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 05E03
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1005E03.dgn
TITLE 24 COMPLIANCE SHEETS 2
115
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:25-07'00'
200

Page 380 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 2:36:14PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 05E04
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1005E04.dgn
TITLE 24 COMPLIANCE SHEETS 3
116
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:40-07'00'
200

Page 381 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023
2:29:10
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
12E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL

POWER GENERATION BUILDING
8660F10 8660F1012E01.dgn
A
01E02
#
GENERAL NOTES:

KEY NOTES:

TYP
EM902
1 TYP
EM173
(TYP)
PLC12199
ANT1-99400 N-5100 2 RAD1-99400 3 N-5000 2

PARTIAL COMMUNICATION PLAN
8660F1012E0101
avates
INSTALLATION.

ADDITIONAL INFORMATION WITH REGARDS TO RADIO EQUIPMENT

2. REFER TO NETWORK BLOCK DIAGRAM DRAWING 04N01 FOR
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PANEL MINIMUM DIMENSIONS SHALL BE 20" H x 20" W x 12" D.

DIMENSIONS AND MANUFACTURER RECOMMENDATIONS. RADIO
OWNER. SIZE RADIO PANEL ACCORDING TO RADIO EQUIPMENT

3. COORDINATE THE EXACT LOCATION FOR RADIO PANEL WITH
ACCORDING TO EA080/TYP.

2. SUPPORT CONDUIT ON WALL WITH PREFORMED CHANNEL
PROVIDE MINIMUM TWO POINT OF SUPPORT FOR MAST POLE.

CHANNEL. WALL ATTACHMENT SHALL BE ACCORDING TO EA080/TYP.

1. MOUNT ANTENNA MAST POLE ON WALL WITH PREFORMED
117
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:56-07'00'
200

Page 382 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
B
B
P
lotD
ate: 05
-APR
-2023 1:21:50
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
60E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1060E01.dgn

DECHLORINATION STRUCTURE

POWER, CONTROL AND LIGHTING PLAN

STRUCTURE

DECHLORINATION
LCP-60102
DISC-60102
FV-60102
FV-60100
DISC-60100
LCP-60100
A
12'-0"
GENERAL NOTES:

GFCI-WP
A
01E02 3/8" = 1'-0"
# KEY NOTES:

AIT-60101 5
1 3
4 PB-6001
P-60-105
N-60-105
TYP
EM015
P-60-106
C-60-105
2 L-60-110
TYP
EM103
TYP
EM001
TYP
EM211
(TYP)
P-60-107
L
02E02
DWG 01E02

CONTINUED ON
N-60-100
P-60-100
C-60-100
P-60-101
P-60-102
TYP
EL507
PBL70271-29
PNL70271-27
NJB-60001
JGB
SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 3/4".

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

5. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
IN THE SAME RACEWAY FOR VOLTAGE DROP.

AND SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS

BE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,

4. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

3. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS CONDUITS AND WIRING IN A SIMILAR MANNER.

ROUTING AS A GUIDE TO INSTALL LIGHTING AND RECEPTACLE
SHOWN. USE THE PROCESS POWER AND CONTROL CONDUIT

2. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER 8660F1060E0101
AND SIGNAL CIRCUITS TO THE NEW UNIT.

EQUIPMENT MOUNTING STAND, AND RECONNECT EXISTING POWER

5. MOUNT NEW ANALYZER UNIT INSIDE THE EXISTING CABINET, ON JUNCTION BOX ACCORDING TO NEC.

INTERNAL WIRING AND DEVICE INFORMATION. SIZE NETWORK

4. REFER TO DRAWING 04N03 FOR NETWORK JUNCTION BOX
NEC. PULL BOX MINIMUM SIZE SHALL BE 12'W X 8"D X 12"H.

3. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO

2. TO LIGHTING FIXTURES AND RECEPTACLES.

DETAIL EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO

1. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING L-60-111
P-60-120
X-60-100
N-60-110
X-60-105
avates
L-60-109
118
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:39:06-07'00'
200

Page 383 of 599 ends

PB-7001
PB-7002
#4/0 SDBC

STATION

SCADA CONTROL

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
P
lotD
ate: 05
-APR
-2023
2:27:15
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
70E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

AB
ASH

ELECTRICAL
8660F10 8660F1070E01.dgn
MCC70292
MCC70291
MCC70293

ELECTRICAL ROOM

RESTROOM
FUTURE
GENERAL NOTES:

DAFT BUILDING ELECTRICAL ROOM
4 TYP
(TYP)
X-89-111
X-89-113
C-89-120
P-89-121
P-89-111
P-89-101
L-89-113
P-89-133
C-91-111
P-91-101
1 TYP
(TYP)
EM001
TYP
EM020
(TYP)
2 S-89-102
X-89-103
EM173
L-89-114
C-91-112
P-91-102
P-89-121
P-89-111
C-89-120
P-89-101
P-89-134
S-89-103
TYP
EM102
(TYP)
C-89-140
C-89-132
C-89-131
C-89-130
N-70-101
N-70-102
N-70-103
N-70-100
N-70-104
S-80-101
C-87-103
P-89-136
P-89-135
P-89-105
P-89-115
P-91-105
P-89-125
X-80-100
X-80-101
1 4
M
02E03
DWG 01E02

CONTINUED ON
TYP
EM105
4 D
W
G 01
E02
CON
TINU
ED ON
K
02E02
VFD-89102
VFD-89101
VFD-89100
VFD-91100
PLC70299
SWB70282
SWB70281
TYP
(TYP)
EG101
# KEY NOTES:

A
01E02 1/4" = 1'-0"
8660F1001E0101
N-60-113
N-60-114
JGB
1 1
3 S350/TYP.

MOUNTED ELECTRICAL EQUIPMENT ACCORDING TO DETAIL

2. PROVIDE EQUIPMENT HOUSEKEEPING PAD FOR NEW FLOOR
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PER DETAIL EG152/TYP.

DETAIL EG101/TYP AND EXOTHERMIC CONNECTION SHALL BE
CONNECTIONS. COMPRESSION CONNECTION SHALL BE PER

CABLE CONNECTION TYPE AND FOLLOW IT TO MAKE THE NEW
RING AND BOND NEW EQUIPMENT TO IT. VERIFY EXISTING

4. FIELD VERIFY AND LOCATE EXISTING GROUNDING ELECTRODE CONDUCTORS INSTALLATION.

EXISTING CIRCUITS IN PLACE DURING NEW CONDUITS AND

3. EXISTING SIGNAL AND COMMUNICATION PULL BOX. PROTECT
BUILDING.

MOUNT PULL BOX ON THE EXTERIOR WALL OF THE DAFT
NEC. PULL BOX MINIMUM SIZE SHALL BE 36"W X 26"D X 36"H.

2. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO ACCORDING TO DETAIL EM219/TYP.

TRANSITIONING BETWEEN DUCT BANK TO EXPOSED ROUTING

1. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS

POWER, CONTROL, AND GROUNDING PLAN
avates
119
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:33:13-07'00'
200

Page 384 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:23:21
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
80E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HR
SMB

ELECTRICAL
8660F10 8660F1080E01.dgn
A
01E02
LIT-80100
GENERAL NOTES:

SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PB-8001
TYP
EM103
TYP
EM001
S-80-100
S-80-101
X-80-100
X-80-101
D
W
G 01
E02
CON
TINU
ED ON
2 1
M
02E03
# KEY NOTES:

JGB
evandoorn
STRUCTURE 80 PLAN
8660F1080E0101

NO SCALE
ACCORDING TO DETAIL EM219/TYP.

TRANSITIONING BETWEEN DUCT BANK TO EXPOSED ROUTING

2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS
10"D X 18"H.

ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 18"W X

1. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
120
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:38:39-07'00'
200

Page 385 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 2:25:12PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 85E01
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1085E01.dgn
A
01E02
8660F1085E0101
C
85E02 85E03 B

AWT BUILDING OVERALL PLAN
3/16" = 1'-0"
JGB
121
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:33:28-07'00'
200

Page 386 of 599 ends

HMI WORKSTATION

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
J
J
J
P
lotD
ate: 05
-APR
-2023 1:20:01
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1085E02.dgn
AWT BUILDING POWER AND CONTROL PLAN 1
M
ATC
H
LIN
E
SEE
D
W
G 85E03
B
85E01
8660F1085E0101
MCC-C
PCM-4
PNL-A
XFMR-A
DP2

STATION
WORK
PMP-85104
PMP-85183
VCP-85183
LCP-85104
S-85-540
C-85-542
C-85-550
S-85-475
S-85-415
C-85-402
C-85-457
P-85-221
P-85-421
C-85-401
S-85-411
C-85-145
P-85-275
P-85-475
C-85-455
S-85-471
C-85-614
C-85-620
C-85-616
PB-8502
PB-8501
PB-8530
2 3
2 P-85-501
C-85-510
C-85-520
C-85-530
S-85-510
S-85-520
S-85-530
C-85-501
C-85-507
C-85-503
C-85-505
C-85-511
C-85-517
C-85-515
C-85-513
P-85-521
C-85-523
C-85-521
P-85-511
C-85-525
C-85-527 C-85-540
P-85-710
P-85-612
C-85-612
P-85-610
C-85-610
1 1
TYP
EM201
TYP
(TYP)
EM102
TYP
(TYP)
EM163
4 JGB
N-85-500
N-85-510
1/4" = 1'-0" -
1 1/2" = 1'-0"
8660F1085E0101
PDSH-85106
BLO-85106
FAN-85109
LCP-85108
FAN-85111
BLO-85108
PDSH-85108
PSH-85108
PIT-85108
LCP-85106
PSH-85106
PIT-85106
PIT-85107
PSH-85107
LCP-85107
PDSH-85107
BLO-85107
FAN-85110
PSL-85100
1 -
P-85-477
P-85-277
P-85-422
P-85-222
C-85-542
P-85-501
P-85-511
P-87-115
C-87-115
S-88-110
L-88-105
C-85-545
P-85-521
C-87-119
P-87-117
P-87-117
S-88-112
C-85-545
S-85-540
VERIFY WHERE NEEDED.

FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL FIELD

DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND SIZES

1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
#
WORK.

CONDUIT, CONDUCTORS, AND SWITCH BOXES TO COMPLETE THE
PANELBOARD. PROVIDE ALL THE NECESSARY EQUIPMENT SUCH AS

4. RELOCATE EXISTING LIGHTING SWITCH TO MAKE ROOM FOR NEW X 12"H.

ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D

3. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
NEC. PULL BOX MINIMUM SIZE SHALL BE 20"W X 12"D X 20"H.

2. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO CONDUCTORS TO THE NEW EQUIPMENT.

EXISTING POWER, CONTROL, AND SIGNAL CONDUITS AND
LOCATED INSIDE VENDOR CONTROL PANEL WITH NEW. RECONNECT

1. REPLACE EXISTING PUMP LOCATED ON PEDESTAL AND PUMP DRIVE GENERAL NOTES:

KEY NOTES:
avates
VCP-3
122
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:38:22-07'00'
200

Page 387 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
B

J B B B J B B B B B J B J B B B

B B J B B J B J
B
B J
B
B

J J J J
B B
P
lotD
ate: 05
-APR
-2023
2:23:56
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85E03
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1085E03.dgn
AWT BUILDING POWER AND CONTROL PLAN 2
M
ATC
H
LIN
E
SEE
D
W
G 85E02
C
85E01
8660F1085E0101
DISC-85248
DISC-85249
FV-85249
FCV-85248
FV-85247
FV-85239
FV-85237
FV-85217
FCV-85218
LSH-85104
LSH-85103 LSH-85102 LSH-85101
DISC-85241
DISC-85232
DISC-85231
DISC-85221
DISC-85222
DISC-85211
DISC-85212
FV-85222
FV-85212
FCV-85221
FCV-85241 FCV-85231
FV-85242
FCV-85211
LSL-85104
LSL-85103 LSL-85102 LSL-85101
DISC-85247
PB-8514
DISC-85239
DISC-85237
DISC-85238
PB-8513 PB-8512
FV-85219
PB-8511
DISC-85219
DISC-85217
DISC-85218
DISC-85227
DISC-85228
FV-85227
DISC-85229
FCV-85228
FV-85229
FV-85244 FV-85234 FV-85224 FV-85214
PB-8524
PB-8523
PB-8522
PB-8521
DISC-85214
DISC-85244 DISC-85234 DISC-85224
P-85-400
P-85-405
S-85-405
S-85-410
P-85-410
P-85-420
C-85-400
P-85-406
P-85-401
P-85-411
P-85-300
P-85-305
S-85-305
P-85-310
P-85-320
C-85-300
S-85-311
C-85-133
C-85-301
P-85-306
P-85-311
P-85-301
P-85-201
P-85-220
C-85-200
S-85-210
P-85-206
P-85-200
P-85-210
C-85-201
S-85-211
C-85-123
P-85-205
S-85-205
P-85-100
P-85-105
S-85-105
P-85-110
S-85-110
P-85-101
P-85-111
P-85-106
P-85-120
C-85-100
C-85-111
C-85-110
C-85-112
C-85-121
C-85-120
C-85-122
C-85-131
C-85-130
C-85-132
C-85-141
C-85-140
C-85-142
FILTER NO. 4 FILTER NO. 3 FILTER NO. 2 FILTER NO. 1
CLARIFIER NO. 4 CLARIFIER NO. 3 CLARIFIER NO. 2 CLARIFIER NO. 1 P-85-150
P-85-155
P-85-160
S-85-150
S-85-170
C-85-150
P-85-170
P-85-161
S-85-270
P-85-156
P-85-151
P-85-260
P-85-261
P-85-250
S-85-250
P-85-255
P-85-256
P-85-251
S-85-271
C-85-251
C-85-250
S-85-370
P-85-360
P-85-361
P-85-355
P-85-350
P-85-351
P-85-356
S-85-371
C-85-351
S-85-350
P-85-370
S-85-470
P-85-460
P-85-461
P-85-455
P-85-450
P-85-451
P-85-456
P-85-470
C-85-450
S-85-450
#
GENERAL NOTES:

KEY NOTES:
1 3
4 6 6
6 TYP (TYP)
EM211

TYP (TYP)
EM221
6 6
5 5
4 5
6 6
5 6
1 2
JGB
7 7 7 7
P-85-221
P-85-421
C-85-401
S-85-411
C-85-145
P-85-275
P-85-475
C-85-455
S-85-471 TYP
EM102
FCV-85238
P-85-211
S-85-310
DISC-85242
FV-85232
C-85-350
1/4" = 1'-0"
P-85-270
C-87-115
S-88-110
P-87-115
S-85-400
LIT-85241 LIT-85221 LIT-85211
S-85-300 S-85-200
LIT-85231
S-85-100
P-87-112
C-87-110
C-87-101
P-87-101
S-88-105
S-87-100
PB-8535
R
02E03
8 9 PB-8530
10 ELECTRICAL AND PROCESS EQUIPMENT.

MAINTENANCE AND REPAIR IS PROVIDED AROUND AWT FILTER

THE OWNER AND ENSURE ADEQUATE SPACE FOR

2. COORDINATE EQUIPMENT MOUNTING STAND LOCATIONS WITH
FIELD VERIFY WHERE NEEDED.

SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL

DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND

1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
avates
TYP
EM102
8"D X 12"H.

ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X

10. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D X 12"H.

9. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING

8. DUCT BANKS CONTINUES ONTO DRAWING 01E02.

STRIPS INSIDE THE JUNCTION BOX.

CONTRACTOR PROVIDED CONDUCTORS, USING TERMINAL
FILTER WALL. TERMINATE LEVEL FLOAT SWITCH CABLE TO

7. PROVIDE A TERMINATION JUNCTION BOX, MOUNTED AT TOP
TO PANELBOARD DP2 SCHEDULE.

INSIDE PULL BOX, TO FEED ASSOCIATED ACTUATOR ACCORDING

PANELBOARD SHALL SPLICE TO THREE DIFFERENT CIRCUITS

ACTUATOR POWER FEEDER CIRCUIT COMING FROM
TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D X 12"H.

6. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING
WITH PREFORMED CHANNEL ACCORDING TO DETAIL EA030/TYP.

5. MOUNT DISCONNECT SWITCH ON THE FILTER EXTERIOR WALL
WASTE GATES.

ASSOCIATED WITH ALL FILTERS, LEVEL INSTRUMENTS, AND
FILTER EXTERIOR WALLS. THIS IS TYPICAL FOR CONDUITS

4. SUPPORT CONDUITS WITH PREFORMED CHANNELS ON THE
THE FILTER EXTERIOR WALL ACCORDING TO DETAIL EA030/TYP.

EM104/TYP. OR SUPPORTED WITH PREFORMED CHANNEL ON

SUPPORTED ON THE GROUND ACCORDING TO DETAIL

3. CONDUIT ROUTING ON THE EAST SIDE OF FILTERS SHALL BE CHANNEL ACCORDING TO DETAIL EA060/TYP.

SUPPORTED UNDER THE PLATFORM WITH PREFORMED

2. CONDUIT ROUTING ON THE WEST SIDE OF FILTERS SHALL BE CEILING LEVEL.

1. CONDUITS FROM THE WEST SIDE OF TANK SHALL RISE TO
123
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:29:00-07'00'
200

Page 388 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
J
P
lotD
ate: 05
-APR
-2023
2:20:27
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
87E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1087E01.dgn
A
01E02
8660F1087E0101

POWER AND CONTROL PLAN

BACKWASH PUMP STATION
GENERAL NOTES:

VERIFY WHERE NEEDED.

FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL FIELD

DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND SIZES

1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD

NO SCALE
# KEY NOTES:

AIT-87130
PMP-87134
LCP-87134
2 TYP
(TYP)
P
02E03
EM001
S-87-100
C-87-101
P-87-101
C-87-100
P-87-100
TYP
EM104
1 TYP (TYP)
EM201
JGB
avates
3 DWG01E02

CONTINUED ON
DWG01E02

CONTINUED ON
3 Q
02E03
TYP
(TYP)
EM015
L-88-102
L-88-101
S-88-102
S-88-101

3. GROUND NEW DUCT BANK TO EXISTING GROUND RING.

DETAIL EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO

2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING CONDUCTOR TERMINATION POINT.

CONDUCTORS AS LONG AS NEEDED TO REACH EQUIPMENT
CIRCUITS TO THE NEW UNIT. EXTEND POWER CONDUITS AND

EQUIPMENT MOUNTING STAND, AND RECONNECT EXISTING POWER

1. MOUNT NEW ANALYZER UNIT ON THE EXISTING ANALYZER
D
W
G01
E02
CON
TINU
ED ON
FV-87130
C-87-105
FV-87130
124
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:35:15-07'00'
200

Page 389 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
JJJ
J
PlotDate: 05-APR-2023 2:16:59PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 89E01
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1089E01.dgn
A
01E02 1/2"=1'-0"
8660F1089E0101
DW G 01E02

CONTINUED ON
DWG 01E02

CONTINUED ON
02E01
# KEY NOTES:
1 33
5 4
PMP-89100
LCP-89100
LCP-89101
PMP-89101
LCP-89102
PMP-89102
PB-8901
GENERAL NOTES:

I
02E02 L
TRF-3E

CAROUSEL PUMP STATION

POWER AND CONTROL PLAN
X-89-100
P-89-131
P-89-101
P-89-111
P-89-121
C-89-120
L-89-111
S-89-101
X-89-101
2 L-60-111
P-60-120
X-60-100
N-60-110
2 C-89-120
S-89-100
L-89-110
L-89-120
P-89-130
P-89-100
P-89-110
TYP P-89-120
(TYP)
EM020

TYP (TYP)
EM211

TYP (TYP)
EM104
C-89-101
C-89-102
C-89-100
3 FSL-89102
C-89-108
C-89-113

TYP (TYP)
EM201
C-89-116
C-89-115
C-89-111
C-89-110
LIT-89103
LSLL-89100
C-89-106
C-89-107
FSL-89101
FSL-89100
X-89-120
X-89-125
N-60-111
X-60-105
-1 KVA TRANSFORMER
- MOTOR CONTROL CABINET
- MAIN DISCONNECT SWITCH, 200 A, 3-POLE
ELECTRICAL EQUIPMENT TO BE DEMOLISHED:

2. REFER TO DRAWING 89D01 FOR LOCATION OF FOLLOWING
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER

TYP (TYP)
EM105
JGB

6. TO LIGHTING FIXTURES AND RECEPTACLES.

CONDUCTORS ON LINE SIDE OF DISCONNECT SWITCH.

DIVERSION METERING VAULT FLOW METER FIT-99105. TERMINATE

5. DISCONNECT SWITCH IS FOR 120V POWER SOURCE TO FLOW
CONDUCTORS ON LINE SIDE OF DISCONNECT SWITCH.

DIVERSION METERING VAULT ACTUATED VALVES. TERMINATE

4. DISCONNECT SWITCH IS FOR 480V POWER SOURCE TO FLOW

3. REPLACE EXISTING PUMP MOTOR WITH NEW MOTOR.

DETAIL EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO

2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING EAST.

POWER/CONTROL CIRCUITS. ACCESS DOORS SHALL BE FACING

PULLING SPACE BETWEEN SIGNAL/COMMUNICATION AND

BOX WITH SEPARATE ACCESS DOORS AND SEPARATE THE CABLE
SHALL BE 30"W X 20"D X 30" H. PROVIDE A DIVIDER INSIDE THE PULL PULL BOX ACCORDING TO NEC. PULL BOX MINIMUM DIMENSIONS

1. POWER, CONTROL, SIGNAL AND COMMUNICATION PULL BOX. SIZE DW G 01E02

CONTINUED ON
6 TYP
EM020
(TYP)
2 avates
LSHH-89100
125
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:21:06-07'00'
200

Page 390 of 599 ends

#6 SDBC
#4/0 SDBC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:20:37
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
89E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1089E02.dgn
B
01E02 1/2"=1'-0"
8660F1089E0201
D
W
G 01
E02
CON
TINU
ED ON
DWG 01E02

CONTINUED ON
02E01
PMP-89100
PMP-89101
PMP-89102
GENERAL NOTES:

I
02E02
L
TRF-3E

CAROUSEL PUMP STATION LIGHTING,

TYP (TYP)
EG002
TYP
EG204
TYP
EG101
(TYP)

GFCI-WP
A
12'-0"

GFCI-WP
A
12'-0"
2 TYP
EG001
(TYP)
# KEY NOTES:

GROUNDING EQUIPMENT ARE NOT IN ADEQUATE CONDITION.

THE EXISTING GROUND RING AND GROUND RODS IF EXISTING
GROUND RING ASSOCIATED WITH THE PUMP STATION. REPLACE

5. FIELD VERIFY CONDITION, LAYOUT AND INTEGRITY OF THE EXISTING INCHES.

SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.

SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND

3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN. evandoorn
1 1
PNL70271-27
PNL70271-29
PNL70271-29
PNL70271-27
JGB

GROUNDING, AND RECEPTACLES PLAN

2. TYPICAL FOR ALL CAROUSEL PUMP MOTOR.

CONDUCTOR ACCORDING TO DETAIL EG101/TYP.

1. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
126
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:29:17-07'00'
200

Page 391 of 599 ends

#4/0 SDBC
PB-9101

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
P
lotD
ate: 05
-APR
-2023
2:11:46
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
91E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1091E01.dgn
A
01E02
8660F1091E0101

POWER AND CONTROL
PMP-91100
B
01E02
8660F1091E0201
A
12'-0"

GFCI-WP
3/8"=1'-0" 3/8"=1'-0"
H
3 LSHH-91101
LSL-91101
L-91-100
X-91-102
C-91-105
C-91-106
P-91-101
C-91-110
X-91-100
LCP-91100
02E01
TYP
TYP
(TYP)

TYP (TYP)
TYP
TYP
TYP
EM020
EM105
EM211
EM115
EG001
EL507
TYP
(TYP)
EG101
TYP
(TYP)
EG002
PMP-91100
1 2
3 FSL-91100
DWG 01E02

CONTINUED ON
DWG 01E02

CONTINUED ON
TYP
EM201
C-91-104
TYP
EM139
PNL70271-27
PNL70271-29

LIGHTING AND GROUNDING
JGB

PAU PUMP STATION PLANS
C-91-100
P-91-100
avates
INCHES.

SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THE 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.

SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND

3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN, #
CONDUCTOR AS PER DETAIL EG101/TYP.

4. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING AS PER DETAIL

3. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING NEC. PULL BOX MINIMUM SIZE SHALL BE 22"W X 12"D X 22" H.

2. POWER AND CONTROL PULL BOX SIZE PULL BOX ACCORDING TO

1. TO LIGHTING FIXTURES AND RECEPTACLES.

GENERAL NOTES:

KEY NOTES:
4 H
02E01
127
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:24:10-07'00'
200

Page 392 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:53:54
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL

EXISTING WATER TREATMENT BUILDING
8660F10 8660F1099E01.dgn
A
02E01
XFMR-A
GEN-A
MCC-E
ATS-E

MCC-XFR

VFD-XFR
MCC-N
SWBD-A
ROOM

ELECTRICAL
JGB
# KEY NOTES:

PNL-RWPS
2 1
-
-

PNL-RWPS
1 2
1 1
-
MCC-E
2 -

PNL-RWPS
X-0010
X-0011
P-0010
P-0011
3 4
6 TYP
EM001
P-0001
P-0002
5 6
3 -
8660F1099E01C

ELECTRICAL ROOM ATTIC
7 7
GENERAL NOTES:
3 -
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATION AND SIZES ARE FROM OWNER

PARTIAL POWER AND CONTROL PLAN
8660F1099E01A 8660F1099E01B
WORK RESTRICTIONS.

CONDUIT WORK. REFER TO SPECIFICATION SECTION 01140 FOR
CONDUITS. PROTECT EXISTING CABLES AND RE-TERMINATE AFTER

7. IF NEEDED FOR TOP HAT CONSTRUCTION, RELOCATE EXISTING STRUCTURAL ENGINEER OF RECORD FOR DIRECTION.

MODIFICATION TO CEILING JOISTS IS NEEDED, CONTACT

MOUNTING SPACE IS OBSTRUCTED BY CEILING JOISTS, AND

DETERMINED DURING FIELD VERIFICATION THAT ENCLOSURE
CONDUIT ENTRY, AND ACCESS LOCATION WITH EATON. IF IT IS JOISTS. COORDINATE NEW TOP HAT ENCLOSURE ACTUAL SIZE,
THAN 8" MAY NEED TO BE PARTIALLY PLACED IN CEILING, BETWEEN

6. HEAD SPACE ABOVE MCC IS APPROXIMATELY 8". TOP HAT HIGHER ROOM. SUPPORT CONDUITS IN ATTIC SPACE PER DETAIL EM901/TYP.

5. ROUTE CONDUITS THROUGH ATTIC SPACE ABOVE ELECTRICAL
CHANNELS ACCORDING TO DETAIL EM903/TYP.

4. SUPPORT CONDUITS ON BUILDING SIDE WALL WITH PREFORMED ELECTRICAL BUILDING.

EM219/TYP, AND ENTER TO THE BUILDING'S ATTIC SPACE, ABOVE

3. CONDUITS RISE FROM DUCT BANK PER DETAIL EM020/TYP AND SPACE FOR PNL-RWPS INSTALLATION.

2. RELOCATE SPD ENCLOSURE IF NEEDED TO PROVIDE ADEQUATE SHALL SUBMIT TOP HAT AND TAP DESIGN FOE ENGINEER REVIEW.

SERVICES TO COMPLETE TOP HAT INSTALLATION. CONTRACTOR
MCC-E. CONTRACTOR TO PROVIDE MANUFACTURER FIELD

PARTS AND ACCESSORIES TO COMPLETE CABLE TERMINATION IN
BE THE SAME AS EXISTING MCC-E. PROVIDE ALL THE NECESSARY POWER CABLES. ENCLOSURE MANUFACTURER AND MODEL SHALL

ACCOMMODATE NEW TAP OF EXISTING MCC-E BUS WITH PNL-RWPS

1. PROVIDE MCC TOP HAT ENCLOSURE TO HOUSE PNL-RWPS POWER.

DWG 01E01

CONTINUED ON
A
01E01 1/4" = 1'-0"
8660F1099E0101
128
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:34:05-07'00'
200

Page 393 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
B
B
P
lotD
ate: 05
-APR
-2023 1:20:25
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1099E02.dgn
99E02
# KEY NOTES:
1 PNL-RWPS-L XFMR-RWPS-L
PCM-99400
SWBD-RWPS VFD-99414 VFD-99413 VFD-99412 VFD-99411

RECYCLED WATER ELECTRICAL BUILDING

POWER AND CONTROL PLAN
JGB
CON
TINU
ED ON
D
W
G 99E03
A CONTINUED ON DWG 01E01
02E01
C
02E01
TYP
(TYP)
EM001
3 X-3200
X-3100
X-3104
X-2100
X-1502
P-2012
C-2015
S-2011
X-2011
P-2022
C-2025
S-2021
X-2021
N-2021
P-2032
C-2035
S-2031
X-2031
P-2042
C-2045
S-2041
X-2041
N-2041
X-2056
X-2052
X-2053
X-2054
X-2051
X-2055
P-2043
P-2033
P-2023
P-2013
TYP
EM020
TYP
(TYP)
EM022 2
N-2011
P-0010
P-0011
P-1000
X-0010
X-0011
L-1102
DISC-99421
L-1101
CU-99421
L-1110
L-1100
CU-99422
TYP
EM173
DISC-99422
L-1112
L-1111
TYP
EM107

TYP (TYP)
EM033
N-3100
N-1000
RAD2-99400
S-3102
L-1000
C-3105
L-3200
L-3102
L-2100
X-2101
L-1200
L-1201
N-2031
GENERAL NOTES:

S-2431
L-2431
X-1501
X-1500
N-2001
5 5
4 EM102/TYP AND EA030/TYP.

3. SUPPORT EXPOSED CONDUITS AS NEEDED ACCORDING TO DETAILS BOTTOM OF ENCLOSURE.

ROOM WITH ELECTRICAL EQUIPMENT CONDUIT ENTRY OPENING AT

2. COORDINATE CONDUIT STUB UP LOCATIONS INSIDE ELECTRICAL CROSS IN CONCRETE SLAB.

DIAMETER LARGER THAN TWO INCHES SHALL NOT STACK OR
EM115/TYP, EM116/TYP, AND EM117/TYP. EMBEDDED CONDUITS WITH

1. EMBEDDED CONDUIT IN SLAB SHALL BE INSTALLED PER DETAILS B
01E01 3/4" = 1'-0"
8660F1099E0101
FCU-99421 FCU-99422
S-3101
C-3102
6 DIMENSIONS SHALL BE 20" H x 20" W x 12" D.

AND MANUFACTURER RECOMMENDATIONS. RADIO PANEL MINIMUM

6. SIZE RADIO PANEL ACCORDING TO RADIO EQUIPMENT DIMENSIONS ANY CHANGES TO ENGINEER FOR REVIEW.

BREAKER RATING AND CABLE SIZE ACCORDINGLY PER NEC. SUBMIT

PROTECTION RATING FOR HVAC UNIT, AND CHANGE CIRCUIT

5. CONTRACTOR SHALL VERIFY MAXIMUM OVER CURRENT
MANUFACTURER INSTALLATION REQUIREMENTS.

NECESSARY CONDUITS AND CABLES ACCORDING TO

4. CONTRACTOR SHALL INSTALL THERMOSTAT, AND PROVIDE
BUILDING SLAB AND TOP OF THE DUCT BANK.

3. PROVIDE MINIMUM OF 6" SPACE BETWEEN BOTTOM OF THE
LOCATION.

2. CONDUITS SHALL REMAIN ENCASED IN DUCT BANK TO STUB UP

1. SPACE IS RESERVED FOR FUTURE RECYCLED PUMP VFD.
avates
X-3101
129
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:38:09-07'00'
200

Page 394 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
S
J
S
J
S
J
S
J
P
lotD
ate: 05
-APR
-2023 1:19:28
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1099E03.dgn

RECYCLED WATER PUMP STATION
99E03
LCP-99411 PMP-99411 PMP-99412 PMP-99413 PMP-99414
FIT-99431

POWER AND CONTROL PLAN
FSL-99411 FSL-99412 FSL-99413 FSL-99414
JGB
DISC-99411
P-2012
S-2011
X-2011
C-2015
C-2019
TYP
(TYP)
EM202
1 TYP
(TYP)
EM020
2 TYP
EM032
3 C
02E01
D
02E01
L-2100
C-2013
C-2012
C-2011
P-2011
DISC-99412
P-2022
S-2021
X-2021
C-2025
C-2029
C-2023
C-2022
C-2021
LCP-99412
DISC-99413
P-2032
S-2031
X-2031
C-2035
C-2039
C-2033
C-2032
C-2031
LCP-99413
P-2042
S-2041
X-2041
C-2045
C-2049
C-2043
C-2042
C-2041
P-2021 P-2031 P-2041
TYP
EM115
(TYP)
X-2051
X-2052
X-2053
X-2054
X-2101
S-2431 X-2100
L-2431
TYP
EM001
(TYP)
S-2430
S-2429 PIT-99432
C
01E01 1/2" = 1'-0"
8660F1099E0102
DISC-99414
LCP-99414
TYP
EM105
(TYP)
CON
TINU
ED ON
D
W
G 99E02
CON
TINU
ED ON
D
W
G 99E04
4 4 4 4
WITH MAXIMUM 2' OF TYPE LIQUID-TYPE FLEXIBLE CONDUIT.

1. FINAL CONDUIT CONNECTION TO PUMP MOTOR SHALL BE MADE #
ENTERING TO THE PUMP TERMINATION BOX.

4. COMBINE POWER AND CONTROL CONDUITS INTO ONE CONDUIT

3. TO PUMP STATION LIGHTING FIXTURES AND RECEPTACLES.

LOCATION.

2. CONDUITS SHALL REMAIN ENCLOSED IN DUCT BANK TO STUB UP ASSOCIATED JUNCTION BOXES, ON THE SAME EQUIPMENT STAND.

1. MOUNT ELECTRICAL DISCONNECT, LOCAL CONTROL PANEL, AND GENERAL NOTES:

KEY NOTES:
130
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:29:54-07'00'
200

Page 395 of 599 ends

HH-4

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
J
J
P
lotD
ate: 05
-APR
-2023
2:09:33
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E04
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLU

ELECTRICAL
8660F10 8660F1099E04.dgn

RECYCLED WATER STORAGE POWER AND CONTROL
SV1-99402
SV2-99402
DWG 99E03

CONTINUED ON
JGB
TYP
EM001
(TYP)
TYP
(TYP)
EM020
TYP
EM202
S-3100 2
C-3100 2
TYP
EM015
ANT2-99400
TYP
EM902
4 F
02E01
5 TYP
EM201
L-3101
X-3100
X-3101
S-3101
C-3102
N-3100
L-3200
S-3200
C-3005
C-3001
C-3003
# KEY NOTES:
5 FIT-99406
C-3002
ZSOC-99402
X-3102
X-3103
TYP
EM315
D
02E01
D
01E01 1/8" = 1'-0"
8660F1099E0104
E
02E01 L-3100
avates
1 LIT-99405
LSHH-99403
LSLL-99403
6 3 DESIC-99405
TERMINATE LEVEL INSTRUMENT CABLES ON IT.

PROVIDE TERMINAL STRIP INSIDE THE JUNCTION BOX AND

6. MOUNT JUNCTION BOX ON THE ROOF NEAR LEVEL INSTRUMENTS. 10E14.

5. LIGHTING AND RECEPTACLE CONDUIT CONTINUES ON DRAWING LUGS.

4. SUPPORT ANTENNA MAST POLE ON TANK EMBEDDED SUPPORT
PROVIDE SST SUN SHADE FOR THE BOX.

3. DESICCANT JUNCTION BOX MINIMUM SIZE SHALL BE 6" x 6" x 6".

EMBEDDED SUPPORT LUGS.

2. SUPPORT CONDUITS WITH PREFORMED CHANNEL ON TANK

1. INSTALL CONDUIT SLEEVE FOR LEVEL INSTRUMENT CABLES.
131
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:36:18-07'00'
200

Page 396 of 599 ends

#4/0 SDBC
#8 SDBC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E12
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

RECYCLED WATER ELECTRICAL BUILDING

LIGHTING, GROUNDING AND RECEPTACLES PLAN
8660F10 8660F1099E12.dgn
R
W PS
-2
R
W PS
-3
G
FCI-W
P
RWPS-3

GFCI-WP
RWPS-2
RWPS-2
RWPS-3

GFCI-WP

TYP (TYP)
EG002
TYP
EG304
TYP
(TYP)
EG205
TYP
(TYP)
EG102
TYP
(TYP)
EM725
TYP
(TYP)
EG511
TYP
EG205
TYP
(TYP)
EG101
TYP
(TYP)
EG001
3 4
1 3
6 5
1 TYP
EL200
TYP
EA030
(TYP)
2 2
6 4
B
9'-0"
a RWPS-1
B
9'-0"
a RWPS-1
B
9'-0"
a RWPS-1
C
9'-0"
RWPS-1
RWPS-1
D
10'-0"
C
9'-0"
RWPS-1
RWPS-1
D
10'-0"
#
GENERAL NOTES:

KEY NOTES:

VFD-99414 VFD-99413
RAD2-99400
PCM-99400 PNL-RWPS-L XFMR-RWPS-L
SWBD-RWPS VFD-99412 VFD-99411
CONTINUED ON DWG 01E01
CON
TINU
ED ON
D
W
G 99E13
CU-99422
CU-99421
INCHES.

SPECIFICATIONS. CONDUITS SHALL NOT BE SMALLER THAN 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

5. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
CONDUCTORS IN THE SAME RACEWAY AND FOR VOLTAGE DROP.

AND SHALL BE DE RATED TO ACCOUNT FOR MULTIPLE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,

4. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE

3. LIGHTING PANEL PNL-RWPS-L IS ABBREVIATED AS RWPS.

AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN. 7 ELECTRICAL
E
01E01 3/4" = 1'-0"
8660F1099E0201
a
RWPS-1
3, D
a
R
W PS
-1
3, D

7. TYPICAL FOR HVAC CONDENSER UNIT.

FIXTURE.

6. PROVIDE EMERGENCY BACKUP LIGHTING PACKAGE FOR THIS

5. SPACE IS RESERVED FOR FUTURE RECYCLED PUMP VFD.

4. CONTINUED ON SHEET 10E13.

CONDUCTOR ACCORDING TO DETAIL EG101/TYP.

3. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING

2. BOND HVAC EQUIPMENT TO THE GROUND RING CONDUCTOR.

CONDUIT AT EXPOSED LOCATIONS.

CONDUCTOR INSIDE MINIMUM SIZE 1-1/2" SCHEDULE 80 PVC
WITH COMPRESSION CONNECTION. INSTALL GROUNDING

1. BOND CEILING METALLIC BEAM TO THE GROUND RING CONDUCTOR C
02E01
A
02E01
avates
132
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:36:44-07'00'
200

Page 397 of 599 ends

#4/0 SDBC
#6 SDBC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023
2:04:51
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL

RECYCLED WATER PUMP STATION

LIGHTING, GROUNDING, AND RECEPTACLES PLAN
8660F10 8660F1099E13.dgn
99E13
PMP-99411 PMP-99412 PMP-99413 PMP-99414
RWPS-5

GFCI-WP
RWPS-5

GFCI-WP
RWPS-5

GFCI-WP
RWPS-5

GFCI-WP
A
12'-0"
RWPS-4
A
12'-0"
RWPS-4
A
12'-0"
RWPS-4
A
12'-0"
RWPS-4
2 2
1 3
TYP S
EL507
TYP
EG101
(TYP)
TYP
EG002
(TYP)
#
GENERAL NOTES:

KEY NOTES:

5. LIGHTING PANEL PNL-RWPS-L IS ABBREVIATED AS RWPS.

INCHES.

SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.

SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND

3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN.

TYP
NF136
4 4. TYPICAL FOR ALL RECYCLED WATER PUMP MOTOR.

3. FOR FUTURE PUMP INSTALLATION.

2. CONTINUED ON SHEET 10E12.

PUMP MOTORS.

INSTALLATION MANUAL. THIS IS TYPICAL FOR ALL RECYCLED WATER

1. BOND MOTOR FRAME ACCORDING TO NEC AND MANUFACTURER
TYP
EL502
F
01E01 3/8" = 1'-0"
8660F1099E0202
D
W
G 99E14
CON
TINU
ED ON
D
W
G 98E12
CON
TINU
ED ON
D
02E01
C
02E01
133
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:39:38-07'00'
200

Page 398 of 599 ends

HH-4

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023
2:02:26
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E14
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL

RECYCLED WATER STORAGE

LIGHTING, GROUNDING, AND RECEPTACLES PLAN
8660F10 8660F1099E14.dgn
RWPS-5

GFCI-WP
2 2
1 A
RWPS-11
15'-0"
A
RWPS-11
14'-0"
TYP
(TYP)
EL506
TYP
(TYP)
EG002
ANT2-99400
# KEY NOTES:

TYP
(TYP)
EG101
TYP
NF136
D
02E01
E
02E01
F
02E01
G
01E01 1/8" = 1'-0"
8660F1099E0204
DWG 99E13

CONTINUED ON
10E04.

2. LIGHTING AND RECEPTACLE CONDUIT CONTINUES ON DRAWING CONDUCTOR ACCORDING TO DETAIL EG101/TYP.

1. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
avates
TYP
EL506
134
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:21:22-07'00'
200

Page 399 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
SYMBOL DRAWING VISIBLE FIELDS FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5 FIELD - 6 FIELD - 7 FIELD - 8 INSTRUMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTING PRIMARY ELEMENT 2 -LOOP NUMBER BUILDING NO. F -FUTURE
3 -FUNCTION ROOM NO.
4 -FURNISHED BY
5 -LOCATION
6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING OUT -OUTDOOR CONTROL ELEMENT 2 -LOOP NUMBER INT -INTEGRAL F -FUTURE
PRIMARY FUNCTION 3 -FUNCTION REM -REMOTE
OPERATOR 4 -FURNISHED BY
ACCESSIBLE 5 -DESCRIPTION
6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING CONTROL ELEMENT 2 -LOOP NUMBER F -FUTURE
AUXILIARY FUNCTION 3 -FUNCTION
OPERATOR 4 -FURNISHED BY
ACCESSIBLE 5 -LOCATION
6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING CONTROL ELEMENT 2 -LOOP NUMBER F -FUTURE
PRIMARY FUNCTION 3 -FUNCTION
OPERATOR 4 -FURNISHED BY
INACCESSIBLE 5 -LOCATION XR -PROTECTION
6 -EXISTING/FUTURE RELAY

CR -CONTROL
RELAY

XR -INTERPOSING
RELAY
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING CONTROL ELEMENT 2 -LOOP NUMBER F -FUTURE
AUXILIARY FUNCTION 3 -FUNCTION
OPERATOR 4 -FURNISHED BY
INACCESSIBLE 5 -LOCATION XR -PROTECTION
6 -EXISTING/FUTURE RELAY

CR -CONTROL
RELAY

XR -INTERPOSING
RELAY
FIELD EQUIPMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTING NON-POWERED 2 -LOOP NUMBER BUILDING NO. F -FUTURE
3 -FUNCTION/SIZE ROOM NO.
4 -FURNISHED BY
5 -LOCATION
6 -EXISTING/FUTURE
FIELD EQUIPMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTING PRIMARY FUNCTION 2 -LOOP NUMBER BUILDING NO. F -FUTURE
POWERED 3 -FUNCTION ROOM NO.
4 -FURNISHED BY
5 -LOCATION
6 -EXISTING/FUTURE
FIELD EQUIPMENT 1 -TAG MWH-MOTOR REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING AUXILIARY FUNCTION 2 -LOOP NUMBER WINDING F -FUTURE
POWERED 3 -FUNCTION HEATER
4 -FURNISHED BY TSH -TEMPERATURE
5 -LOCATION SWITCH
6 -EXISTING/FUTURE XSH -TORQUE
SWITCH
FIELD EQUIPMENT 1 -TAG MS -MOTOR REFER FVNR -FULL VOLTAGE 120VAC -1P LCP -LOCAL CONTROL E -EXISTING STARTER/DRIVE 2 -LOOP NUMBER STARTER NON-REVERSING STARTER 208VAC -2P PANEL NO. F -FUTURE CUBICLE/CABINET 3 -TYPE RVAT-REDUCED FVR -FULL VOLTAGE 208VAC -3P MCC -MOTOR CONTROL 4 -VOLTAGE-POLE VOLTAGE AUTO REVERSING STARTER 240VAC -2P CENTER NO. 5 -POWER SOURCE TRANSFORMER PWS -PART-WINDING STARTER 240VAC -3P PCM -PROCESS CONTROL 6 -EXISTING/FUTURE STARTER RVAT -REDUCED VOLTAGE AUTO 480VAC -3P MODULE NO.

RVSS-REDUCED RVSS -REDUCED VOLTAGE 2400VAC -3P VCP -VENDOR CONTROL VOLTAGE SOLID STATE STARTER 4160VAC -3P PANEL NO.

SOLID STATE TS1W -TWO SPEED SINGLE

STARTER WINDING
VFD -VARIABLE TS2W -TWO SPEED TWO WINDINGS

FREQUENCY VFD -VARIABLE FREQUENCY

DRIVE DRIVE

INSTRUMENT BUBBLE LOCATIONS NOTES
PC
S

INSTRUMENT TAG IDENTIFICATION LETTERS TABLE

OPERATOR PILOT DEVICE LEGEND
I/O

EQUIPMENT TAGGING TABLE

I/O TYPE DESIGNATIONS
O
PER
ATO
R
INTER
FAC
E/
CON
TR
O
L
D
EV
IC
E
S

INSTRUMENT TYPE DESIGNATIONS TABLE
FURNISHED BY: FBO FURNISHED BY OWNER

FBV FURNISHED BY VENDOR
P
O
W
ER
SOURC
E
PROVIDED BY: PBO PROVIDED BY OWNER

PBV PROVIDED BY VENDOR
FIELD
SYMBOL DRAWING VISIBLE FIELDS FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5 FIELD - 6 FIELD - 7 FIELD - 8 HMI/SCADA SYSTEM 1 -TAG REFER REFER ACTION DESCRIPTION DESCRIPTION E -EXISTING OPERATOR 2 -LOOP NUMBER ALARM F -FUTURE
INTERFACE 3 -FUNCTION SP -NUMERIC
TERMINAL 4 -DESCRIPTION STATUS -SET POINT
5 -DESCRIPTION TREND
6 -EXISTING/FUTURE
HARDWIRED I/O 1 -TAG REFER REFER AI -ANALOG INPUT DESCRIPTION PAC -PROGRAMMABLE E -EXISTING POINT 2 -LOOP NUMBER AO -ANALOG OUTPUT AUTOMATION F -FUTURE 3 -FUNCTION DI -DISCRETE INPUT CONTROLLER NO.
4 -DESCRIPTION DO -DISCRETE OUTPUT PLC -PROGRAMMABLE
5 -LOCATION RTD -RTD INPUT LOGIC
6 -EXISTING/FUTURE CONTROLLER NO.
7 -IO TABLE RIO -REMOTE I/O

VCP -VENDOR CONTROL
PANEL NO.

NETWORK / SOFT I/O 1 -TAG REFER REFER COMMUNICATION PROTOCOL DESCRIPTION PAC -PROGRAMMABLE E -EXISTING 2 -LOOP NUMBER CNET -CONTROLNET AUTOMATION F -FUTURE
3 -PROTOCOL DNET -DEVICENET CONTROLLER NO.
4 -PANEL EIP -ETHERNET/IP PLC -PROGRAMMABLE
5 -PLC FF -FOUNDATION FIELDBUS LOGIC
6 -EXISTING/FUTURE HART-I -HART OVER ETHERNET CONTROLLER NO. 7 -IO TABLE MANF -MFR. PROPRIETARY RIO -REMOTE I/O
8 -SWITCH/SEGMENT MBRTU -MODBUS RTU VCP -VENDOR CONTROL MB+ -MODBUS PLUS PANEL NO.

MBTCP -MODBUS TCP

DP -PROFIBUS DP

PA -PROFIBUS PA

PNET -PROFINET
SNMP -SNMPv3

HTTP -WEB SERVER (TCP/IP)
LOCAL 1 -TAG REFER REFER ACTION DESCRIPTION LOI -LOCAL OPERATOR E -EXISTING OPERATOR 2 -LOOP NUMBER ALARM INTERFACE NO. F -FUTURE
INTERFACE 3 -FUNCTION SP -NUMERIC LCP -LOCAL CONTROL
4 -DESCRIPTION STATUS -SET POINT PANEL NO.
5 -LOCATION TREND PCM -PROCESS CONTROL
6 -EXISTING/FUTURE MODULE NO.

VCP -VENDOR CONTROL
PANEL NO.

PILOT DEVICE 1 -TAG REFER REFER AM -AUTO/MANUAL DESCRIPTION LCP -LOCAL CONTROL E -EXISTING OPERATOR 2 -LOOP NUMBER BYPASS -BY PASS PANEL NO. F -FUTURE INTERFACE 3 -FUNCTION E-STOP -EMERGENCY STOP MCC -MOTOR CONTROL 4 -DESCRIPTION FRLR -FIXED RATE/LEVEL RATE CENTER NO.
5 -LOCATION HOA -HAND/OFF/AUTO PCM -PROCESS CONTROL
6 -EXISTING/FUTURE LOR -LOCAL/OFF/REMOTE MODULE NO.

LOS -LOCK OUT STOP RVS -REDUCED VOLTAGE
LS -LEAD/STANDBY SOLID STARTER NO.

LSR -LOCAL/STOP/REMOTE VCP -VENDOR CONTROL
NOOT -NO OFFLINE/OFFLINE PANEL NO.

TRANSITION VFD -VARIABLE

OC -OPEN/CLOSE FREQUENCY
OLOL -ON LINE/OFFLINE DRIVE NO.

OO -OFF/ON

OSC -OPEN/STOP/CLOSE

RST -RESET

SAAM -SEMI AUTO/AUTO/MANUAL

SEL -SELECT

SPD -SPEED

SS -START/STOP

ST -STOP
POWER DEVICE 1 -TAG CB -CIRCUIT REFER TM -THERMAL MAGNETIC 24VDC -1P DP -DISTRIBUTION E -EXISTING PRIMARY FUNCTION 2 -LOOP NUMBER BREAKER CIRCUIT BREAKER 24VDC -2P PANEL NO. F -FUTURE OPERATOR 3 -FUNCTION DISC -DISCONNECT 24VAC -1P LCP -LOCAL CONTROL ACCESSIBLE 4 -VOLTAGE-POLE FU -FUSE 48VDC -2P PANEL NO. 5 -LOCATION 120VAC -1P LP -LIGHTING PANEL NO.
6 -EXISTING/FUTURE 208VAC -2P MCC -MOTOR CONTROL
208VAC -3P CENTER NO.
240VAC -2P PCM -PROCESS CONTROL
240VAC -3P MODULE NO.
480VAC -3P PP -POWER PANEL NO.
2400VAC -3P VCP -VENDOR CONTROL
4160VAC -3P PANEL NO.

POWER DEVICE 1 -TAG DISC -DISCONNECT REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING AUXILIARY FUNCTION 2 -LOOP NUMBER F -FUTURE
OPERATOR 3 -DESCRIPTION
ACCESSIBLE 4 -DESCRIPTION
5 -DESCRIPTION
6 -EXISTING/FUTURE
POWER DEVICE 1 -TAG CB -CIRCUIT REFER MCP -MOTOR CIRCUIT 24VDC -1P DP -DISTRIBUTION E -EXISTING PRIMARY FUNCTION 2 -LOOP NUMBER BREAKER PROTECTOR 24VDC -2P PANEL NO. F -FUTURE OPERATOR 3 -FUNCTION FU -FUSE SS -SOLID STATE 24VAC -1P LCP -LOCAL CONTROL INACCESSIBLE 4 -VOLTAGE-POLE CIRCUIT BREAKER 48VDC -2P PANEL NO. 5 -LOCATION TM -THERMAL MAGNETIC 120VAC -1P LP -LIGHTING PANEL NO. 6 -EXISTING/FUTURE CIRCUIT BREAKER 208VAC -2P MCC -MOTOR CONTROL 208VAC -3P CENTER NO.
240VAC -2P PCM -PROCESS CONTROL
240VAC -3P MODULE NO.
480VAC -3P PP -POWER PANEL NO.
2400VAC -3P VCP -VENDOR CONTROL
4160VAC -3P PANEL NO.
1 2
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
8 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 7
3 1 2 3 2 5
1 2 3
1 2 3
1 2 3 2 5
3 3
3 4
1 3 5 6 7
1 1
1 3
1 3
3 3
3 3
3 3
3 3
3 3
5 6 7
6 7
6 7
6 7
6 7
6 7
6 7
1-2
3 4
5 6

1 2
3 4
5 6
7 1
2 3
4 8
5 6
7 P
lotD
ate: 06-APR
-2023
7:18:58
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN01
SYMBOLS AND ABBREVIATIONS 1
8660F1000GN01.dwg
lbordelon
8660F10
135
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:18:19-06'00'
200

Page 400 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

TO PROCESS

INSTRUMENT OR CONNECTION
(GUIDED)

ELECTROMAGNETIC OR SONIC SIGNAL
(NOT GUIDED)

ELECTROMAGNETIC OR SONIC SIGNAL
(SOFTWARE OR DATA LINK)

INTERNAL SYSTEM LINK

PNEUMATIC SIGNAL

ELECTRIC SIGNAL

HYDRAULIC SIGNAL

CAPILLARY TUBE

IN PIPE

PRIMARY PROCESS FLOW

IN PIPE

SECONDARY PROCESS FLOW

IN CHANNEL

PRIMARY PROCESS FLOW

IN CHANNEL

SECONDARY PROCESS FLOW

EQUIPMENT ENCLOSURE

EXISTING

DESIGNATIONS

MISCELLANEOUS P&ID SYMBOLS

PIPE CALLOUT

PROCESS CONTINUATION

INSTRUMENT TAG IDENTIFICATION LETTERS P&ID LINE SYMBOLS

PROCESS LINE SYMBOLS
FUTURE

SIGNAL CONTINUATION
TYP
*

SCHEMATIC DETAIL

TYPICAL DETAIL
FUTURE

CONTINUATION
SHEET
UNIQUE

IDENTIFIER

CONTINUATION
SHEET
UNIQUE

IDENTIFIER

I/O TYPE DESIGNATIONS INSTRUMENT TYPE DESIGNATIONS SPECIFIC ABBREVIATIONS AUX1 RUNNING MSL MOTOR START LOW CGD COMBUSTIBLE GAS DETECTOR RTD RESISTANCE TEMP DETECTOR HTR HEATER AUX2 FAILED/FAULT MSM VALVE MODULATE COND CONDUCTIVITY SB SLUDGE BLANKET HTU HEAT TRACE UNIT AUXF1 RUNNING FORWARD MSP MOTOR STOP DO DISSOLVED OXYGEN SC STREAMING CURRENT MWH MOTOR WINDING HEATER AUXH1 RUNNING HIGH MSR MOTOR START REVERSE FMCW FREQ. MODULATED CONT. WAVE SD SLUDGE DEPTH SV SOLENOID VALVE AUXL1 RUNNING LOW MST MOTOR START IS INTRINSIC SAFETY BARRIER SH SODIUM HYPOCHLORITE SPD SURGE PROTECTIVE DEVICE AUXR1 RUNNING REVERSE SS SPEED SIGNAL LEL LOWER EXPLOSIVE LIMIT SO2 SULFUR DIOXIDE UPS UNINTERRUPTIBLE POWER SUPPLY

SVC SOLENOID VALVE CLOSE ZC POSITION COMMAND MLSS MIXED LIQUOR SUSPENDED SOLIDS TDR TIME DOMAIN REFLECTOMETRY YA STATUS AUTO

SVO SOLENOID VALVE OPEN ZCC POSITION COMMAND CLOSE ORP OXIDATION REDUCTION POTENTIAL TOC TOTAL ORGANIC CARBON YR STATUS REMOTE MS RUN ZCO POSITION COMMAND OPEN P-SUB PRESSURE SUBMERSIBLE TSS TOTAL SUSPENDED SOLIDS Y1 STATE RUNNING MSF MOTOR START FORWARD PC PARTICLE COUNTER UVI UV INTENSITY Y2 ALARM FAILED/FAULT

MSH MOTOR START HIGH PTOF PULSE TIME OF FLIGHT UVT UV TRANSMITTANCE

OPERATOR PILOT DEVICE LEGEND

PILOT DEVICE FUNCTION

DEVICE TYPE
LO
C

AL-OFF-R
EM
OTE
(LO
R
)O
R
LO
C
AL-S
TO
P
-R
EM
OTE
(LS
R
)
S
TO
P
(SP
)
S
TAR
T
(S
T)
HAND
-OFF-AU
TO
(HOA
)
OFF-ON
(OO
)
SELEC
T
(SEL)
O
PEN
-S
TO
P
-C
LO
S
E
(O
S
C
)
JOG
O
PEN
-HO
LD
-C
LO
S
E
(JOH
C
)
S
EM
IAU
TO
-AU
TO
-MANUAL
(SAAM
)
LEAD
-LAG
-S
TAND
B
Y
(LLG
S
)
JOG
O
PEN
-JOG
C
LO
S
E
(JO
JC
)
ON
LIN
E
-OFFLIN
E
(O
LO
F)
AU
TO
-MANUAL
(AM
)
FIXED
R
ATE
-LEVEL
R
ATE
(FR
LR
)
O
PEN
-C
LO
S
E
(O
C
)
NO
OFFLIN
E
-OFFLIN
E
TRAN
S
ITION
(NOO
T)
LO
W
-H
IGH
(LH
)
R
E
SET
(R
S
T)
SPEED
(SPD
)
S
TAR
T
-S
TO
P
(S
TSP
)
E
-S
TO
P
(E
-SP
)
B
YPASS
(B
YP
)
S
ILEN
C
E
P
O
S
ITION
(P
O
S
)
PILOT DEVICE TAG (HAND SWITCHES) HSA* HSB HSC HSD* HSE HSF HSG HSH HIS HSJ* HSK HSL* HSM* HSN HSO HSP HSQ* HSR HSS HST* HSU HSV HSW HSX HSY HSZ PLC I/O TAG: * = R (REMOTE), A (AUTO), ETC.

INSTRUMENT FUNCTION

MEASURED VARIABLE
ELEM
EN
T
TRAN
S
M
ITTER
IND
IC
ATING
TRAN
S
M
ITTER

CONVERTER
TRAN
SDU
C
ER,

RELAY SPEC
IAL
D
EV
IC
E
S
IND
IC
ATO
R
R
EC
O
R
D
ER
CON
TR
OLLER
IND
IC
ATING
CON
TR
OLLER
R
EC
O
R
D
ING
CON
TR
OLLER
S
W
ITC
H
S
W
ITC
H
LO
W
LO
W
S
W
ITC
H
LO
W
S
W
ITC
H
H
IGH
S
W
ITC
H
H
IGH
H
IGH
S
W
ITC
H
C
O
M
B

INATION
H
IGH
LO
W
AC
TION
ALAR
M
LO
W
LO
W
ALAR
M
LO
W
ALAR
M
H
IGH
ALAR
M
H
IGH
H
IGH
TO
TALIZE
IND
IC
ATO
R
TRAN
S
M
ITTER
VALVE
GAUG
E
LIGH
T
SPEED

SETTING

A ANALYSIS AE AT AIT AY AI AR AC AIC ARC AS ASLL ASL ASH ASHH ASHL AALL AAL AAH AAHH AL

B BURNER FLAME BE BT BIT BY BI BR BC BIC BRC BS BSLL BSL BSH BSHH BALL BAL BAH BAHH BL

C CONDUCTIVITY CE CT CIT CY CI CR CC CIC CRC CS CSLL CSL CSH CSHH CSHL CALL CAL CAH CAHH CL

D DENSITY DE DT DIT DY DI DR DC DIC DRC DS DSLL DSL DSH DSHH DSHL DALL DAL DAH DAHH DL

E VOLTAGE ESL

F FLOW FE FT FIT FY FI FR FC FIC FRC FS FSLL FSL FSH FSHH FSHL FALL FAL FAH FAHH FQI FCV FG FL

FF FLOW RATIO FFY FFI FFC FFIC FFS FFL
H HAND (MANUAL)* HC HS* HA* HV HL HSS
I CURRENT IT IIT lY II IR IC llC IRC IS ISLL ISL ISH ISHH IALL IAL IAH IAHH lL

J POWER

K TIME KY KI KR KC KIC KRC KS KSLL KSL KSH KSHH KALL KAL KAH KAHH KV KL

L LEVEL LE LT LIT LY LI LR LC LIC LRC LS LSLL LSL LSH LSHH LSHL LALL LAL LAH LAHH LCV LG LL

M MOISTURE OR HUMIDITY ME MT MIT MY MI MR MC MIC MRC MS MSLL MSL MSH MSHH MALL MAL MAH MAHH ML

N USER'S CHOICE

P PRESSURE OR VACUUM PE PT PIT PY PI PR PC PIC PRC PS PSLL PSL PSH PSHH PSHL PALL PAL PAH PAHH PCV PL

PD DIFFERENTIAL PRESSURE PDT PDIT PDY PDI PDR PDC PDIC PDRC PDS PDSLL PDSL PDSH PDSHH PDALL PDAL PDAH PDAHH PDCV PDL

Q QUANTITY QE QT QIT QY QI QR QS QSLL QSL QSH QSHH QALL QAL QAH QAHH

R RADIATION

S SPEED SE ST SIT SY SI SR SC SIC SRC SS SSLL SSL SSH SSHH SALL SAL SAH SAHH

T TEMPERATURE TE TT TIT TY TI TR TC TIC TRC TS TSLL TSL TSH TSHH TSHL TALL TAL TAH TAHH TCV TL

TD DIFFERENTIAL TEMPERATURE TDT TDIT TDY TDI TDR TDC TDIC TDRC TDS TDSLL TDSL TDSH TDSHH TDALL TDAL TDAH TDAHH TDCV TDL

U MULTIVARIABLE UI UR UC UIC URC US UL

V VISCOSITY VE VT VIT VY VI VR VC VIC VRC VS VSLL VSL VSH VSHH VALL VAL VAH VAHH VL

W WEIGHT WE WT WIT WY WI WR WS WSLL WSL WSH WSHH WALL WAL WAH WAHH

X UNCLASSIFIED XE XT XIT XY XI XR XC XIC XRC XS XSLL XSL XSH XSHH XALL XAL XAH XAHH XCV XG XL

XV VIBRATION XVE XVT XVY XVI XVR XVS XVSH XVSHH XVAH XVAHH XVL Y STATUS*** YI YL
Z POSITION ZE ZT ZIT ZY ZI ZS** ZV ZL**
* REFER TO OPERATOR PILOT DEVICE LEGEND
** LETTER INDICATES POSITION (O=OPEN, C=CLOSED, R=RAISE, L=LOWER, ETC)

PIPE SIZE
TYPNUM
TYPNUM2
TYPNUM3
TYPNUM4
TYPNUM5
TYPNUM6
?
-
# DWG NO.

DESC1_
DESC2_
# DWG NO.

DESC1_
DESC2_
P
lotD
ate: 06-APR
-2023
7:19:14
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN02
SYMBOLS AND ABBREVIATIONS 2
8660F1000GN02.dwg
lbordelon
8660F10
136
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:18:43-06'00'
200

Page 401 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

ACTUATORS
O
C
BALL

DOUBLE FLAP

FLAPPER
SWING

CHECK VALVES PRESSURE VALVES

REGULATING

PRESSURE RELIEF

VACUUM RELIEF
S
VALVES

AIR-RELIEF
ANGLE
BALL

BUTTERFLY
CONE

DIAPHRAGM
3-WAY PLUG
4-WAY
3-WAY

BALL V-NOTCH
GATE
GLOBE
HOSE
MUD
NEEDLE
PINCH

PLUG ECCENTRIC

PLUG CONCENTRIC

TELESCOPING

PUMP DISCHARGE
S
P
S
P
S

DIAPHRAGM

PNEUMATIC
HAND

HYDRAULIC
S
S
S
S
S
P
S
P
~
IY
I/P
PIPING

AIR GAP

BLIND FLANGE
DRAIN
PUMPS

AIR DRIVEN

CENTRIFUGAL

DIAPHRAGM
GEAR
PISTON

SUBMERSIBLE

WATER CHAMP
FAN

BASKET STRAINER

COALESCER

EDUCTOR/EJECTOR

VAPORIZER

BLOW-OFF SILENCER

INLINE DUCT DAMPER

GAS CANNON

GRINDER

HEAT EXCHANGER

HORIZONTAL MIXER
FILTER

FILTER SEPARATOR

FLAME ARRESTER

EYEWASH

FINE FILTER

FLOW CONDITIONER

HOSE CONNECTION

INLET STRAINER
MIXER
MOTOR
NOZZLE

RUPTURE DISK

SAMPLE PORT

SIGHT TUBE

VAPOR HEATER
OR
MISC

VALVE DESIGNATIONS

NO NORMALLY OPEN

NC NORMALLY CLOSED

FO FAIL OPEN

FC FAIL CLOSE

FLP FAIL LAST POSITION

SMOKE DETECTOR

FIRE ALARM/SENSOR
HOIST

EXHAUST FAN

SOLENOID

DISCRETE

ELECTRIC

MODULATING

ELECTRIC

HYDRAULIC

ELECTRIC

MODULATING

HYDRAULIC

OPEN/CLOSE

SINGLE SOLENOID

PNEUMATIC
w/ SPEED CONTROL

SINGLE SOLENOID

PNEUMATIC

OPEN/CLOSE

DUAL SOLENOID

PNEUMATIC

OPEN/HOLD/CLOSE

DUAL SOLENOID

PNEUMATIC
w/ SPEED CONTROL

OPEN/CLOSE

DUAL SOLENOID

PNEUMATIC

MODULATING

PNEUMATIC
w/ SPEED CONTROL

OPEN/CLOSE

MODULATING

PNEUMATIC

PLUGGED

CAPPED OR

INCREASER

CONCENTRIC

REDUCER

CONCENTRIC

INCREASER

ECCENTRIC

REDUCER

ECCENTRIC

COUPLING

EXPANSION
CENTER

VIBRATION

EXPANSION JOINT

CONNECTION

FLEXIBLE

DISCONNECT
QUICK

OR HOSE

PERISTALTIC
CAVITY

PROGRESSIVE

TURBINE

VERTICAL

CHOPPER

VERTICAL
BLOWER

SINGLE STAGE

CENTRIFUGAL
BLOWER

MULTI STAGE

CENTRIFUGAL

COMPRESSOR

RECIPROCATING

COMPRESSOR
SCREW

COMPRESSOR

LIQUID RING
BLOWER

ROTARY LOBE
DRYER

DESICCANT
COLUMN

CALIBRATION
-BURIED VALVE BOX

PLUG CONCENTRIC

LUBRICATED

PLUG CONCENTRIC
BOX

BURIED VALVE

LUBRICATED

PLUG CONCENTRIC
w-VALVE BOX

PLUG ECCENTRIC

LUBRICATED

PLUG ECCENTRIC

VALVE BOX

LUBRICATED BURIED

PLUG ECCENTRIC

BURIED VALVE BOX
BUTTERFLYPRESSURE TAP

EXTERNAL

REDUCING

PRESSURE

SELF CONTAINED

REDUCING

PRESSURE

EXTERNAL TAP

REGULATING

BACKPRESSURE

SELF CONTAINED

REGULATING

BACKPRESSURE
SWING

SPRING LOADED

GENERAL

SPRING LOADED
CHECK

DIAPHRAGM

INLINE STATIC MIXER

MATERIAL CHANGE

COMPRESSORS

BLOWERS/
VALVE

OPERATED
w/THERMALLY

FLAME ARRESTER

SAMPLER

COMPOSITE

PERISTALTIC

RESTRICTION

ORIFICE

DAMPENER

PULSATION
DRYER

REFRIGERATED

CLEANED

MECHANICALLY

STRAINER -

WITH BLOW OFF

STRAINER

WYE TYPE

STRAINER

ATMOSPHERE

VENT TO
UNION
TEE
P
P
P

DIAPHRAGM

CHEMICAL FEED
OR
VENT

PREVENTER

BACK FLOW

VALVE BOX

GATE-BURIED

DIFFUSER

AIR / CHEMICAL

LOCATOR

EQUIPMENT/INSTRUMENT
E
D
E
M
E
H
H
P
S
M

LOUVER OR DAMPER
FLOAT

CONNECTION

FLANGED
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN03
SYMBOLS AND ABBREVIATIONS 3
8660F1000GN03.dwg
lbordelon
8660F10
137
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:18:56-06'00'
200

Page 402 of 599 ends

IDENTIFIER
UNIQUE

IDENTIFIER
UNIQUE
SHEET

CONTINUATION
SHEET

CONTINUATION

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

ORIFICE

DISPLACEMENT
POSITIVEVORTEX
V-CONE

THERMAL
BATCH

CORIOLIS

MAGNETIC

PADDLE WHEEL

ROTAMETER

BUBBLER

CAPACITANCE

ELECTRODE
FLOAT

INVERTED COLUMN

RADAR PTOF

RADAR TDR

ULTRASONIC
GAUGE

PRESSURE SWITCH
KNIFE
SLIDE
SLUICE
STOP
SLIDE
SLUICE
STOP
FLAP
WEIR

PARSHALL

LEOPOLD-LAGCO

PALMER-BOWLUS

TRAPEZOIDAL

CUTTHROAT

REGULAR
w/ END CONTRACTIONS

RECTANGULAR

TURBINE
PROPELLEROR FLOW NOZZLE

VENTURI TUBE

PRESSURE

DIFFERENTIAL

SUBMERSIBLE

SUSPENDED/

ANNULAR
SEAL

DIAPHRAGM
SEAL

SANITARY
SEAL

PRESSURE SWITCH

MANOMETER

PRESSURE DIFFERENTIAL PRESSURE PRESSURE SEALS

INDICATOR

DIFFERENTIAL
GAUGE

TRANSMITTER

PRESSURE
SWITCH

PRESSURE

DIFFERENTIAL

TRANSMITTER

PRESSURE

DIFFERENTIAL

TUNING FORK
PISTON
WEIRS

SIDE VIEW PLAN VIEW

FLOW FLUMES LEVEL

SIDE VIEW PLAN VIEW
w/o END CONTRACTIONS

RECTANGULAR
w/o END CONTRACTIONS

RECTANGULAR
w/ END CONTRACTIONS

RECTANGULAR
(TRIANGULAR)

V-NOTCH
(TRIANGULAR)

V-NOTCH
(CIPOLLETTI)

TRAPEZOIDAL
(CIPOLLETTI)

TRAPEZOIDAL

PRESSURE/VACUUM

EXAMPLE
GATES

PITOT TUBE

ANNUBAR

ULTRASONIC
BIOGAS

ULTRASONIC

THERMOMETER

HYDRAULIC

STRAIN GAUGE
w/THERMOWELL

TEMPERATURE
GAUGE

TEMPERATURE
WEIGHT

TEMPERATURE
PROBE

CONTINUOUS WAVE)

MODULATED
(FREQUENCY
RADAR

BUTTERFLY
MM
K
N
A
T
T

NETWORKS

OPTIC CABLE
24-STRAND FIBER

REPRESENTS ONE

FIBER LINE
24/FO-SM

OPTIC CABLES
24-STRAND FIBER

REPRESENTS TWO

FIBER LINE
(2) 24/FO-SM (1) 24/FO-SM EA.

OPTIC CABLE
24-STRAND FIBER

REPRESENTS ONE

EACH FIBER LINE

FIBER ABBREVIATIONS
XX = MODE
FO = FIBER OPTIC
## = STRAND COUNT
##/FO-XX
MM = MULTIMODE
SM = SINGLE MODE
(4)
CABLES

COPPER ETHERNET

REPRESENTS FOUR

COPPER LINE
(2) EA.

CABLES

COPPER ETHERNET

REPRESENTS TWO

EACH COPPER LINE

NETWORK ABBREVIATIONS

VLAN SYMBOLS
= BUSINESS NETWORK
= SECURITY CONTROL NETWORK
= BUILDING MANAGEMENT SYSTEM
= PROCESS CONTROL NETWORK

MISCELLANEOUS NETWORK SYMBOLS

NETWORK CABLE CONTINUATIONS

CONTINUATION

TOP OF PAGE STYLE

FIELD NETWORK DEVICE

NETWORK EQUIPMENT CALLOUT
TAG
DESC 1

CABLE CALLOUTS AND ABBREVIATIONS
FPP
ES
NP
NR
PCN-W
SCN
PLCN
PCN
MIN
FCN
BSN
BMS
= FIBER PATCH PANEL
= ETHERNET SWITCH
= NETWORK PANEL
= NETWORK RACK
= WIRELESS PROCESS CONTROL NETWORK
= SECURITY CONTROL NETWORK
= PLC NETWORK
= PROCESS CONTROL NETWORK
= MAINTENANCE INFORMATION NETWORK
= FIELD CONTROL NETWORK
= BUSINESS NETWORK
= BUILDING MANAGEMENT SYSTEM

COPPER ETHERNET

FIBER OPTIC ETHERNET

WIRELESS ETHERNET

PROFIBUS DP

PROFIBUS PA

NETWORK LINE SYMBOLS

STYLE CONTINUATION

BOTTOM/LEFT OF PAGE
SYMBOL

DEVICE SPECIFIC
= WIRELESS PROCESS CONTROL NETWORK
= MAINTENANCE INFORMATION NETWORK
= PLC NETWORK
= FIELD CONTROL NETWORK

SERIAL DATA
PDIT
PDSL
PSH
PSH
PIT
PE
PE
PDE
PDE
PE
PI PDI
SEGMENT #

P&ID DRAWING REFERENCE
DESC 3
DESC 2
DESC 1
TAG

PROTOCOL

PANEL TAG

PLC TAG
#
DWG NO.

DESC 1
DESC 2
DESC 3
#
DWG NO.

DESC 1
DESC 2
DESC 3
GATE
WASTE
P
lotD
ate: 06-APR
-2023
7:16:13
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN04
SYMBOLS AND ABBREVIATIONS 4
8660F1000GN04.dwg
lbordelon
8660F10
138
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:19:21-06'00'
200

Page 403 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

PROCESS SWITCHES HAND SWITCHES RELAYS TERMINAL BLOCKS I/O MISC

CLOSE ON RISING LEVEL

FLOAT SWITCH

OPEN ON RISING LEVEL

FLOAT SWITCH

CLOSE ON RISING PRESSURE

PRESSURE SWITCH

OPEN ON RISING PRESSURE

PRESSURE SWITCH

CLOSE ON RISING TEMPERATURE

TEMPERATURE SWITCH

OPEN ON RISING TEMPERATURE

TEMPERATURE SWITCH

CLOSE ON INCREASE IN FLOW

FLOW SWITCH

OPEN ON INCREASE IN FLOW

FLOW SWITCH

OPEN ON RISING VIBRATION

VIBRATION SWITCH

CLOSE ON RISING VIBRATION

VIBRATION SWITCH

OPEN ON HIGH TORQUE

TORQUE SWITCH

THREE POSITION SELECTOR SWITCH

TWO POSITION SELECTOR SWITCH

MUSHROOM HEAD PUSHBUTTON

MAINTAINED CONTACT

PUSH-PULL PUSHBUTTON

PULL CORD SWITCH

IN PLC/PCM PANEL

TERMINAL

IN MOTOR CONTROL CENTER

TERMINAL

IN LOCAL STARTER CONTROL PANEL

TERMINAL

AT FIELD DEVICE

TERMINAL

IN FIELD PANEL

TERMINAL

IN (USER CHOICE)

TERMINAL

DIGITAL BUS CONNECTOR
a = INPUT OR OUTPUT AS INDICATED

PLC DISCRETE

DIGITAL BUS

SOLENOID
M = TYPE

METER UNIT
MOTOR

CIRCUIT BREAKER

DISCONNECT
FUSE
* - MOTOR TAG I.D.

MOTOR WINDING HEATER

VARISTOR

CAPACITOR

RESISTOR

BATTERY
DIODE

OVERLOAD CONTACT

DRAWOUT CONNECTION
GROUND

LIGHTNING ARRESTOR
a = INPUT OR OUTPUT AS INDICATED

PLC ANALOG
IN RTU

TERMINAL

STOP-LOCKOUT PUSHBUTTON

SPRING-RETURN

SPACE HEATER

ELAPSED TIME METER

PADLOCK SWITCH

xox
xo
xoo
ANALOG
a

DIGITAL
BUS
a
M
MWH-*
KI-*
ETM
HP
a
b
c
d
H1 H3 H2 H4
X1 X2

xoo

CLOSE ON HIGH TORQUE

TORQUE SWITCH
NCTC
NCTO
NOTC
NOTO

CONTROL CONTACT

NORMALLY CLOSED

CONTROL CONTACT

NORMALLY OPEN

TIMED CLOSING

NORMALLY OPEN

TIME DELAY CONTACT

TIMED OPENING

NORMALLY CLOSED

TIME DELAY CONTACT

TIMED OPENING

NORMALLY OPEN

TIME DELAY CONTACT

TIMED CLOSING

NORMALLY CLOSED

TIME DELAY CONTACT

LIMIT SWITCH

NORMALLY CLOSED

HELD OPEN LIMIT SWITCH

NORMALLY CLOSED

LIMIT SWITCH

NORMALLY OPEN

HELD CLOSED LIMIT SWITCH

NORMALLY OPEN

MOMENTARY PUSHBUTTON

NORMALLY OPEN

MOMENTARY PUSHBUTTON

NORMALLY CLOSED

TRANSFORMER

CONTROL POWER

HEATERS

MOTOR OVERLOAD

PROTECTION

TRANSIENT SURGE

CLOSED IN
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS

CLOSED IN

CLOSED IN

CLOSED IN
d = DESCRIPTION
c = TIMING RANGE/SETTING

TDOFF - TIME DELAY ON DEENERGIZATION
b = TDON - TIME DELAY ON ENERGIZATION

R -MOTOR STARTER COIL - REVERSE

F -MOTOR STARTER COIL - FORWARD

H -MOTOR STARTER COIL - HIGH SPEED

L -MOTOR STARTER COIL - LOW SPEED

M -MOTOR STARTER COIL

TD -TIME DELAY RELAY

CR -CONTROL RELAY
a = TYPE

RELAY COIL
* = E -ETHERNET
* = H2 -FOUNDATION FIELDBUS H2
* = H1 -FOUNDATION FIELDBUS H1
* = DP -PROFIBUS DP
* = PA -PROFIBUS PA
* = D -DEVICENET

INDICATORS
HORN
C = CLEAR
M = MAGENTA
B = BLUE
A = AMBER
W = WHITE
G = GREEN
R = RED
a = LENS COLOR
BEACON
C = CLEAR
Y = YELLOW
B = BLUE
A = AMBER
W = WHITE
G = GREEN
R = RED
a = LENS COLOR
a PILOT LIGHT
a
a
H
*
P
lotD
ate: 06-APR
-2023
7:19:21
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
AAW

INSTRUMENTATION

SCHEMATIC SYMBOLS
8660F10 8660F1000GN05.dgn
BAL
00GN05
139
awills
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:19:49-06'00'
200

Page 404 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

TERMINAL PANEL
PCM-300
PLC
MCC-1201
VFD
REMOTE
REMOTE
STOP
START
REMOTE
AUX1-210

RUNNING
FAIL
AUX2-210

WINDING
MOTOR
MWH-210
HEATER
MOTOR

CONNECTION
J-BOX
J-BOX
MWH
210
PMP
210
TSH
210
PSH
210
PE
210
M
J-BOX

SPEED IN
LOCAL
HSAL-210
LOCAL
MODE
FIT
210
FE
210
FQT
210
OFF

LOCAL REMOTE
xoo
oox

STOP
LOCAL
HSB-210
STOP

HSC-210
LOCAL
START
LCP-210
PMP-210

UTILITY WATER PUMP
MOTOR:

INV. DUTY, TEFC
TOSHIBA MODEL: XYZ
PUMP
200 GPM @ 20 FT TDH
900-1800 RPM
GOULD MODEL: XYZ
MODEL: XYZ
RANGE: 0-200 PSIG
SETPOINT: 50 PSIG

ENDRESS HAUSER
CAT NO.: XYZ
FLOW RANGE: 200-2500 GPM
FLOW TOTAL: 1 PULSE/500 GAL
(PSH210-1/PCM300-CB1300H2)
(PSH210-2/PCM300-C0001)
AQ0001+
AQ0001-
SHLD
FU1300-P1
FU1300-M1
<BLK-1>
<WHT-1>
FU1300-H1
I001
<BLK>
Q001A
<BLK>
Q001B
<RED>
E-STOP
Q002A
<BLU>
C0001
Q002B
CB1-210H
CB1-210N
120VAC
FU1300-P2
FU1300-M2
FU1300-P3
<BLK-1>
<WHT-1>
<BLK-2>
<WHT-2>
C0004
FU1300-H3
I003
<BLU>
I004
FU1300-H4
<ORG>
FU1300-H5
I006
<YEL>
(VFD210-11,12/PCM300-AQ001)
(VFD210-13,14/PCM300-AI001)
(VFD210-15/PCM300-Q001A)
(VFD210-16/PCM300-Q001B)
(VFD210-17/PCM300-Q002A)
(VFD210-18/PCM300-Q002B)
(FIT210-L/PCM300-CB1210H)
(FIT210-N/PCM300-CB1210N)
(FIT210-1,2/PCM300-AI002)
(FQT210-4,5/PCM300-FU1300P3; C0004)
(VFD210-20/PCM300-I003)
(VFD210-22/PCM300-I004)
(LCP210-3/PCM300-FU1300H5)
(LCP210-4/PCM300-I006)
(MWH210-H/VFD210-33)
(MWH210-C/VFD210-X2)
(PMP210-T1/VFD210-T1)
(PMP210-T2/VFD210-T2)
(PMP210-T3/VFD210-T3)
(TSH210-NC/PCM300-CB1300H1)
(TSH210-C/PCM300-I001)
(LCP210-P1/VFD210-1)
(LCP210-P2/VFD210-2)
(LCP210-P3/VFD210-3)
(LCP210-1/VFD210-5)
(LCP210-2/VFD210-6)
(LCP210-5/VFD210-7)
(LCP210-6/VFD210-8)
(LCP210-7/VFD210-9)
(LCP210-8/VFD210-10)
HSS
210
HSA
210
HSB
210
HSC
210
FE/FIT/FQT-210
PE/PSH-210
START

(CB1300-H)
AI001+
SHLD
FU1300-H2
C0002
C0003
(VFD210-24/PCM300-C0003)
(VFD210-23/PCM300-C0002)
(VFD210-19/PCM300-FU13000H3)
(VFD210-21/PCM300-FU1300H4)
SHLD
AI002+
120 VAC
MODEL: XYZ

PHOENIX
GND
SHLD
(C0002)
(C0003)
(C0001)
(CB1300-H6) (I005)
(C0004)
(FU1300-M3)
(CB1300-H7) (I002)
(PSH210-1/PCM300-C001)
(PSH210-1/PCM300-FU1300H2)
(TSH210-NC/PCM300-I001)
(TSH210-NC/PCM300-FU1300H1)
(FU1300-P)
M M
(CB1-300N1)
1 2
3 4
5 6
7 8
210
%AQ001

SPEED OUT
RACK 1
SLOT 2
1 2
210
%AI001

SPEED IN
RACK 1
SLOT 3
TSH
210
%I001

MTR TEMP
RACK 1
SLOT 4
MSP
210
%Q001
STOP
RACK 1
SLOT 5
PSH
210
%I005

HI PRESS
RACK 1
SLOT 4
F
210
%AI002
FLOW
RACK 1
SLOT 2
FQ
210
%I002

FLOW TOT
RACK 1
SLOT 4
AUX1
210
%I003

RUNNING
RACK 1
SLOT 4
AUX2
210
%I004
FAIL
RACK 1
SLOT 4
HSAR
210
%I006
REMOTE
RACK 1
SLOT 4
210
%Q002
START
RACK 1
SLOT 5
8 3
4 11
12 7
5 6
4 3
3 4
10 9
1 2
1 1
2 2
3 1
5 6
2 4
4 2
5 6
1 3
23 24
22 21
19 20
18 17
15 16
14 13
12 11
T3
T1
T2
X2
33 9
10 8
7 6
5 4
2 1
3 CR1
210
CR2
210
120 VAC
MODEL: XYZ

PHOENIX

UTILITY WATER HIGH PRESSURE

UTILITY WATER FLOW METER
120 VAC
24 VDC
CB1-300H
FU1-300P
+
-
FU1-300M
CB1-300N (CB1300-N)
SS-210
SB-210
SS
SB
OUT
SPEED
IN
SPEED
VFD-210
SECTION - 3
CUBICLE - 2
30HP, 480VAC, 42 AMPS
CONSTRUCTION. THE LOOP DIAGRAM SHOWN ABOVE DISPLAYS THE LEVEL OF EXPECTED DETAIL.

DIAGRAMS FOR THE ENTIRE FACILITY. PRELIMINARY DETAILED LOOP DIAGRAMS TO BE SUBMITTED FOR REVIEW PRIOR TO BEGINNING THE ABOVE DRAWING IS INCLUDED AS AN EXAMPLE ONLY AND IS NOT PROJECT SPECIFIC. CONTRACTOR SHALL FURNISH LOOP C-01-002
S-01-001
S-01-003
L-01-001
C-01-001
C-01-003
P-01-001 P-01-002
S-01-002
P1
P2
P3

MSP-210
MS-210 MS
H
C
C
1 2
L
N
G
1 2
4 5
T1
T2
T3
NC
P
lotD
ate: 06-APR
-2023
7:19:29
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
AAW

INSTRUMENTATION

SAMPLE LOOP DRAWING
8660F10 8660F1000GN06.dgn
BAL
00GN06
140
awills
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:20:14-06'00'
200

Page 405 of 599 ends

1/4"
6 1/4"
2"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
XXX AMPS, XXX VOLTS, 1Ø
CP-99400
PLC-99400
XXX AMPS, XXX VOLTS, 1Ø
CP-99400
PLC-99400
11 0
31 0
90 70 50
30°F
Pfannenberg
2 1
N L

TEST MONTHLY

SEE INSTRUCTIONS

RESETRESET
TEST
TEST N
NO
C
COM
/G N L L N /G

QUINT POWER
AC 100-240V
L
Input
N

22.5-28.5V
DC OK
Adjust
OutputDC 24V 5A
13 OK 14 DC

QUINT POWER
AC 100-240V
L
Input
N

22.5-28.5V
DC OK
Adjust
OutputDC 24V 5A
13 OK 14 DC
8 6
LNK
ACT
LNK
ACT
4 2
LNK
ACT
LNK
ACT
7 5
3 1
LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
!

LNK/ACT

LNK/ACT
X
2 F
X
1 F
LNK
GB1 ACT GB2
11 0
31 0
90 70 50
30°F
Pfannenberg
2 1
P
lotD
ate: 06-APR
-2023
7:19:39
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
AAW

INSTRUMENTATION
8660F10 8660F1002N001.dgn
SCALE:

FILE:
1 -

NAMEPLATE DETAIL
6' = 1'-0"
1 -
3 19
13 21
18 17
5 6
4 2
1 7
8 POWER ON
SCALE:

FILE:
2 - 6' = 1'-0"
2 -
22 15
16 15
12 CP-99400 PANEL ELEVATION EXTERIOR
8660F1000N671.2dm
8660F1000N671.2dm
8 8 8 8
8 8
11 20
23 8
PCM-99400 PANEL ELEVATION INTERIOR
25 28
26 GENERAL NOTES:

PCM-99400 ELEVATION LAYOUT
02N01
9 14
CABINET.

7. QUANTITY OF COMPONENTS VARY AS REQUIRED FOR EACH
PENETRATIONS ALLOWED.

BOTTOM OF THE ENCLOSURE. NO SIDE, FRONT, OR REAR

6. ALL CONDUIT PENETRATIONS SHALL BE LOCATED AT THE TOP OR CONTROL CABINETS.

5. NO 480VAC CIRCUITS SHALL TERMINATE IN OR PASS THROUGH SHORT CIRCUIT RATINGS.

4. FOLLOW ALL UL 508 AND 508 SUPPLEMENT 5B TO DETERMINE THE NATIONAL ELECTRIC CODE.

3. CONSTRUCT PANEL TO MEET THE FULL INTENT OF ARTICLE 409 OF

2. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.

NUMBERS.

LAYOUT WITH ALL EQUIPMENT, MANUFACTURERS, AND PART

TO SUPPLY AS-BUILT DRAWINGS SHOWING FINAL ENCLOSURE

1. ENCLOSURE DRAWING REPRESENTS DESIGN INTENT. CONTRACTOR BAL
lbordelon
27 PILOT DEVICES DETAIL

CONTROL PANEL - BILL OF MATERIALS

ITEM DESCRIPTION
1 ENCLOSURE
2 NAMEPLATE
3 DATA POCKET
4 INTRUSION DOOR SWITCH
5 INTERNAL FOLDING SHELF
6 CABINET LIGHT WITH DOOR SWITCH
7 POWER PILOT LIGHT
8 WIRE DUCT (AS REQUIRED)
9 DIN RAIL (AS REQUIRED)
10 NOT USED
11 PLC CHASSIS
12 MANAGED ETHERNET SWITCH
13 ANALOG TERMINAL BLOCKS (AS REQUIRED)
14 RECEPTACLE
15 POWER SUPPLY, 24VDC (2 EA.)
16 REDUNDANCY MODULE
17 24VDC POWER DISTRIBUTION TERMINALS
18 120VAC SURGE PROTECTOR
19 CP POWER DISTRIBUTION
20 DISCRETE TERMINAL BLOCKS
21 GROUND BAR
22 TEMPERATURE SWITCH
23 CONTROL RELAYS
24 NOT USED
25 LOCAL OPERATOR INTERFACE (LOI)
26 ELECTRONIC CIRCUIT PROTECTOR
27 COOLING FAN
28 EXHAUST GRILLE
141
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:21:48-06'00'
200

Page 406 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
lotD
ate: 06-APR
-2023
7:20:44
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
LMB

INSTRUMENTATION
8660F10 8660F1002N002.dgn
02N02
lbordelon
BAL
PCM-4 PANEL MODIFICATIONS
2 1
3 4
6 5
3 PCM-4 PANEL ELEVATION INTERIOR PCM-4 PANEL ELEVATION EXTERIOR EXISTING PLC-3 PANEL ELEVATION INTERIOR (NOT SHOWING THE COMPLETE INTERIOR)
# KEY NOTES:
7 8 9
9 REMOVED PER KEY NOTE 5.

THE SAME FUNCTIONALITY AS WAS PRESENT INCLUDING THE ITEMS NEW PLC. ADDITIONALLY, THE NEW PLC AND LOI SHALL PROVIDE

9. ALL EXISTING PROGRAMMING SHALL BE REPROGRAMMED IN THE SHALL BE INSTALLED ON THE PLATE SPECIFIED IN KEY NOTE 6.

SPECIFIED IN CONTRACT DRAWINGS AND SPECIFICATION 17721. LOI

8. PROVIDE AND INSTALL NEW LOCAL OPERATOR INTERFACE AS
THE PANEL'S NEMA RATING.

LIGHTS, SELECTOR SWITCHES, AND PUSH BUTTONS TO MAINTAIN

7. USE APPROPRIATE PLUGS TO INDIVIDUALLY COVER THE PILOT TO INSTALL THE NEW LOI.

BOLT A PLATE TO COVER THE HOLE. THIS PLATE SHALL BE UTILIZED

6. CUT ONE LARGE SQUARE HOLE IN THE AREA SHOWN, GASKET AND SCADA AS NEEDED.

FUNCTIONALITY SHALL BE REPLICATED ON THE NEW LOI AND

PUSH BUTTONS, PILOT LIGHTS, AND SELECTOR SWITCHES

CHART RECORDER, REDIPANEL KEYPAD MODULE, ANNUNCIATOR,
SELECTOR SWITCHES AND RETURN TO THE OWNER. EXISTING

MODULE, ANNUNCIATOR, PUSH BUTTONS, PILOT LIGHTS, AND

5. REMOVE EXISTING CHART RECORDER, REDIPANEL KEYPAD
SPECIFICATIONS.

MAY BE REQUIRED PER CONTRACT DRAWINGS AND

RELAYS, TERMINAL BLOCKS, FUSES AND CIRCUIT BREAKERS THAT

4. UTILIZE THE IDENTIFIED EMPTY SPACES AS NEEDED FOR ANY NEW TO THESE NEW PATCH PANELS AS SHOWN ON 04N02.

FIBER PATCH PANEL LOCATED IN PLC-3 AND SHALL BE CONNECTED PLC-12199 PANELS SHALL BE DISCONNECTED FROM THE EXISTING EXISTING FIBER CONNECTIONS COMING FROM PLC-70299 AND
TRACE AND FIELD VERIFY EXISTING FIBER CONNECTIONS. THE TWO SPECIFIED IN CONTRACT DRAWING AND SPECIFICATION 17733.

3. PROVIDE AND INSTALL NEW FIBER PATCH PANEL IN PLC-4 AS 04N02.

NETWORK CONNECTIONS AS SHOWN ON CONTRACT DRAWING
CONTRACT DRAWINGS AND SPECIFICATION 17733. CONNECT

PROCESSOR WAS PREVIOUSLY INSTALLED AS SPECIFIED IN

AND INSTALL ETHERNET SWITCH IN THE SPACE WHERE THE OLD

2. REMOVE PLC PROCESSOR AND RETURN TO THE OWNER. PROVIDE CONNECTED TO THE EXISTING PLC.

SAME SLOT NUMBER AND IO POINT AS THEY WERE PREVIOUSLY

POSSIBLE, TERMINATE EXISTING IO WIRES TO THE NEW PLC IN THE BEFORE REMOVING WIRES FROM THE EXISTING PLC. WHERE

VERIFY ALL EXISTING IO WIRING AND NETWORK CONNECTIONS
CONTRACT DRAWINGS AND SPECIFICATION 17720. TRACE AND FIELD OWNER. PROVIDE AND INSTALL NEW PLC AS SPECIFIED IN

1. REMOVE EXISTING PLC RACK AND MODULES AND RETURN TO THE 142
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:22:14-06'00'
200

Page 407 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
lotD
ate: 06-APR
-2023
8:32:55
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
LMB

INSTRUMENTATION
8660F10 8660F1002N003.dgn
02N03
crollins
BAL
1 # KEY NOTES:

PLC-70299 PANEL MODIFICATIONS
2 2
PLC-70299 PANEL ELEVATION INTERIOR
143
TERMINAL BLOCKS, FUSES AND RELAYS.

2. UTILIZE EMPTY AREAS IF ADDITIONAL SPACE IS REQUIRED FOR NEW NEW TERMINAL BLOCKS AND FUSES AS NEEDED.

HORIZONTAL SPACE CREATED BY THE SMALLER PLC CHASSIS FOR RELAYS TO TERMINATE NEW IO POINTS AS REQUIRED. UTILIZE

PROVIDE AND INSTALL DIN RAIL, TERMINAL BLOCKS, FUSES AND AS SHOWN ON CONTRACT DRAWING 04N03 AND SPECIFICATION.

PROVIDE AND INSTALL ETHERNET SWITCH AND FIBER PATCH PANEL

1. REMOVE EXISTING EMPTY PLC RACK AND RETURN TO THE OWNER.

Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:22:35-06'00'
200

Page 408 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
POWER
STATUS

ADDRESS/ERROR
ControlNet

MODULE NET
# KEY NOTES:
5 1
2 4
3 TOP OF GENERATOR BUILDING.

7. OMNIDIRECTIONAL BASE STATION ANTENNA. TO BE INSTALLED ON PUMP STATION.

6. COMMUNICATES WITH NEW TRANSCEIVER AT RECYCLED WATER

5. COMMUNICATES WITH NEW TRANSCEIVER AT WWTP.

CONTROL PANEL.

4. INSTALL COAXIAL CABLE SURGE PROTECTION DEVICE IN THE MAST.

3. MINIMUM 10 FT. LOOP OF ANTENNA CABLE AT BASE OF ANTENNA ENDS AGAINST WEATHER.

2. 10 FT. 2" GRC MAST FOR ANTENNA MOUNTING. CAP MAST BOTH

1. HIGH-GAIN YAGI ANTENNA.
2 4
3 7
1 3
2 4
PWR
FANS
ALARM
STATUS
HA
TEMP
USB
5 7
6 8
9 11
10 12
MA1
MA2
MGT

CONSOLE
CLEI

CONSOLE

NEARBY SCADA SYSTEM CABINET

SYSTEM INTERFACE LOCATED IN

DATA LINK TO EXISTING SCADA
PCM-99400

RADIO PANEL

RECYCLED WATER PUMP STATION
FW-99400
RAD1-99400
6 ANT1-99400
RAD2-99400
ANT2-99400
HMI-99400
SW-99400
PLC-99400
PQM-99400
99N001
PUMP #1

RECYCLED WATER
PMP-99411
PLC-99400 EIP
99N002
PUMP #2

RECYCLED WATER
PMP-99412
PLC-99400 EIP
99N002
PUMP #3

RECYCLED WATER
PMP-99413
PLC-99400 EIP
99N002
PUMP #4

RECYCLED WATER
PMP-99414
PLC-99400 EIP
99N003
PUMP #5

RECYCLED WATER
PMP-99415
PLC-99400 EIP

ELECTRICAL BUILDING
8 6
LNK
ACT
LNK
ACT
4 2
LNK
ACT
LNK
ACT
7 5
3 1
LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
!

LNK/ACT

LNK/ACT
X
2 F
X
1 F
LNK
GB1 ACT GB2

RADIO PANEL

POWER GENERATION BUILDING
WWTP

SWBD-RWPS
P
lotD
ate: 06-APR
-2023
8:19:54
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL
04N01
144

INSTRUMENTATION

RECYCLED WATER PUMP STATION

NETWORK BLOCK DIAGRAM
8660F1004N001.dwg
crollins
8660F10
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:55:01-06'00'
200

Page 409 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PLC1-4
LOI-4
LOI
ESP-4
12/FO-MM
FPP1-4

FIBER PATCH PANEL
GENERAL NOTES:

NEEDED FOR A FULLY FUNCTIONAL SYSTEM.

4. PROVIDE ADDITIONAL HARDWARE AND CONFIGURATION AS
OTHERWISE NOTED.

3. COMMUNICATION PROTOCOL SHALL BE ETHERNET/IP, UNLESS
PATCHED THROUGH TO DEVICES AS SHOWN.
(NOT SHOWN FOR CLARITY) OR SURGE PROTECTION DEVICE AND

ENCLOSURE SHALL BE MADE THROUGH COPPER PATCH PANELS

2. ALL COPPER CONNECTIONS FROM DEVICES EXTERNAL TO THE
CONNECTIONS, UNLESS NOTED OTHERWISE.

1. PROVIDE DUPLEX PATCH CABLES FOR ALL INTERNAL FIBER

BUILDING

EQUIPMENT
DAFT
PLC70299

BUILDING

GENERATION
POWER
PLC12199
12/FO-MM
FPP2-4

FIBER PATCH PANEL
PCM-4

TREATMENT BUILDING

ADVANCED WASTEWATER
VCP-3

WORKSTATION

EXISTING HMI

VENDOR CONTROL PANEL

AWT CLARIFIER/FILTER
P
lotD
ate: 06-APR
-2023
7:17:16
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
04N02

ADVANCED WASTEWATER TREATMENT

NETWORK BLOCK DIAGRAM
8660F1004N002.dwg
lbordelon
8660F10
145
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:23:11-06'00'
200

Page 410 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
12/FO-MM
FPP1-70299

FIBER PATCH PANEL
GENERAL NOTES:

SHOWN.

1. DRAWING REFLECTS NEW SCOPE. EXISTING CONNECTIONS NOT NJB-60001

DECHLORINATION FACILITY
FPP1-60001

FIBER PATCH PANEL
ESF-70299

ETHERNET SWITCH

TO EXISTING ETHERNET

CONNECTIONS
60N001
VALVE 1

DCL STRUCTURE
FV-60100
PLC-70299 EIP
PLC-70299

DAFT BUILDING
60N001
VALVE 2

DCL STRUCTURE
FV-60102
PLC-70299 EIP
LNK
ACT
SPD
1000
10/100/1000Base-T
RX
TX

LNK ACT
1000Base-SX/LX
LNK
ACT
SPD
1000
10/100/1000Base-T
RX
TX

LNK ACT
1000Base-SX/LX

ETHERNET SWITCH
MC1-60001

MEDIA CONVERTER
MC2-60001

MEDIA CONVERTER
89N001
CAROUSEL PUMP 1
PMP-89100
PLC-70299 EIP
89N001
CAROUSEL PUMP 2
PMP-89101
PLC-70299 EIP
89N001
CAROUSEL PUMP 3
PMP-89102
PLC-70299 EIP
91N001
PAU PUMP 1
PMP-99100
PLC-70299 EIP
P
lotD
ate: 06-APR
-2023
7:16:31
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

CGR

INSTRUMENTATION
04N03

DAFT BUILDING NETWORK BLOCK DIAGRAM
8660F1004N003.dwg
lbordelon
8660F10
DB
BAL
146
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:23:36-06'00'
200

Page 411 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
VFD-*
480V
MWH-*
CR1-*
SPD
H1 H3 H2 H4
X1 X2
M
VFD

RUNNING
1Ø CONTROL TRANSFORMER
480V PRI
120V SEC
CR

DI REMOTE
DO
PORT

PROGRAMMING
SERIAL

ETHERNET
IP
DO

RUNNING
HSC-*
START

oox

HSA-*
OFF

LOCAL REMOTE
xoo
DI
DO DO
TSH-*
DI
DI

DI SPARE
GROUND
GENERAL NOTES:

POWER (L) POWER (N)
PMP-*
SPEED
HSS-*
LOCAL
SPEED
* = 99411 PMP - 99411
* = 99413 PMP - 99413
* = 99414 PMP - 99414
AUX
3 -*
POWER
FSL-*

3. REFER TO SPECIFICATION 17101 FOR CONTROL DESCRIPTIONS.

INDICATED LOADS.

2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL BASED ON THE SELECTED MANUFACTURER.

THE OPERATION SHOWN HERE AND DESCRIBED IN 17100 AND 17101 MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM

1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
TAG LOOP REFERENCE DWG.
99N01

STOP
HSB-*
1 RECYCLED WATER PUMPS
99N01, 99N02

DI STOP

DI START
* = 99412 PMP - 99412 99N02
99N02
99N02
SPARE

MODULE (HM)

HUMAN INTERFACE

VFD KEYPAD/

COMPONENTS

SPECIFICATIONS FOR INPUT

DIAGRAMS AND

REFER TO ONE-LINE

DESIGN TOPOLOGY

AND SPECIFICATIONS FOR VFD

REFER TO ONE-LINE DIAGRAMS

OUTPUT COMPONENTS

SPECIFICATIONS FOR

DIAGRAMS AND

REFER TO ONE-LINE

HIGH TEMPERATURE

LOW FLOW
CR1-*
1 # KEY NOTES:

1. FLOW SWITCH SHALL BE RESET THROUGH THE PCS.

P
lotD
ate: 06-APR
-2023
7:19:47
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
TCD

INSTRUMENTATION
8660F10 8660F1006N001.dgn
06N01
CONTROL SCHEMATIC 1
BAL
147
crollins
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:24:34-06'00'
200

Page 412 of 599 ends

120VAC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
GENERAL NOTES:

KEY NOTES:

REQUIREMENTS.

COMPONENTS TO MEET PROJECT
ONLY. PROVIDE ALL NECESSARY

1. SCHEMATIC ILLUSTRATES DESIGN INTENT
#

RECEPTACLE
GFCI
6 120VAC SURGE PROTECTIVE DEVICE
24VDC SURGE PROTECTIVE DEVICE
H N G
8 2
2 (AS REQUIRED)

I/O POWER
(AS REQUIRED)

INSTRUMENT POWER
2 (AS REQUIRED)

PLC POWER SUPPLY
UL
UL
UL
G
G
G
N
N
N
2 (WHERE APPLICABLE)
LOI
UL
G
N
L1 N
GND
+ -
SUPPLY
POWER

SWITCHING
24VDC OUT
2 L1 N
GND
+ -
SUPPLY
POWER

SWITCHING
IN 1 IN 2
- +
+ -
24VDC OUT
UL
UL
G
G
N
N
+ -
XA4-*
SPD2 FAIL
INPUT

SIG COM

SIG COM

JS4-*
ACB OK
INPUT

JS3-*

REDUNDANCY OK
INPUT

SIG COM

JS2-*

POWER SUPPLY OK
INPUT

SIG COM

JS1-*

POWER SUPPLY OK
INPUT

SIG COM

INPUT

XA7-*

ECP-P FAIL
INPUT

XA5-*

ES-P FAIL
INPUT

(AS REQUIRED)

SIGNAL ISOLATORS
(AS REQUIRED)

INSTRUMENT POWER
(AS REQUIRED)

PLC I/O MODULES
-
-
-
+
+
+

LINE NEUTRAL GND
5 H THERMOSTAT N
3 CONDITIONER

CABINET FAN / AIR
9 9
G
LIGHT

CABINET
9 G
G
N
N
H
H
5A-1P
24VDC OUT

SIG COM

TSH-*

HIGH CABINET TEMP
INPUT

SWITCH

TEMPERATURE

SIG COM

ZS1-*

INTRUSION
INPUT

DOOR SWITCH
4 ECP

SIG COM

(PLC)

ETHERNET SWITCH
ES-P

SIG COM

-
G
+ -
2 TAG LOOP REFERENCE DWG.
2 5

LOCATED WITHIN PCM CABINET

CONTINUED AT UPPER RIGHT

CONTINUED AT LOWER LEFT

TERMINAL BLOCK LEGEND
PCM
H
N
G
UL
+
-
120VAC

NEUTRAL
GROUND
UPS 120VAC
24VDC (+)
24VDC (-)

SPD FAIL
(AS REQUIRED)

TELEMETRY RADIO
+ -

SPECIFICATIONS.

9. PROVIDE QUANTITY REQUIRED PER
PCM CABINET.

EACH INSTRUMENT POWERED FROM THE

PROVIDE SEPARATE CIRCUIT BREAKERS FOR

8. SIZE BASED ON PROTECTION NEEDS.

7. NOT USED.

LAPTOP.

SPECIFICATIONS. SIZE RECEPTACLE FOR

6. PROVIDE QUANTITY REQUIRED PER

5. SIZE BASED ON LOAD REQUIREMENT.

NON-OVERLAPPING DOORS.

SWITCHES, WIRED IN SERIES, FOR
OVERLAPPING DOORS. PROVIDE ADDITIONAL

4. INSTALL SWITCH ON OUTERMOST DOOR OF
CIRCUIT IF REQUIRED.

CALCULATIONS. PROVIDE ADDITIONAL

3. VERIFY LOADS BASED ON TEMPERATURE

2. SIZE BASED ON PROTECTION NEEDS.

1. NOT USED.

XA6-*
* = 99400 PCM-99400 99N04

DISCRETE-ANALOG PCM CABINET

PLC AND INSTRUMENT POWER
99N04
P
lotD
ate: 06-APR
-2023
7:19:54
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
TCD

INSTRUMENTATION
8660F10 8660F1006N002.dgn
06N02
CONTROL SCHEMATIC 2
BAL
148
awills
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:24:58-06'00'
200

Page 413 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
M PMP-*
TM
GND
480V
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
120VAC
MOV
CR3-*
CR

RUNNING
VFD
3 TAG LOOP REFERENCE DWG.

CAROUSEL PUMPS
89N01
* = 89100 PMP-89100
* = 89101 PMP-89101 89N01
89N01
* = 89102 PMP-89102 89N01
SPEED
LOCAL
HSS-*
SPEED

ETHERNET
IP
CR3-* MWH-*
TSH-*
DI
GENERAL NOTES:

DI

POWER
FSL-*
1 CONVERTER MODULES AS NEEDED FOR FUNCTIONALITY SHOWN.

3. PROVIDE EXPANSION MODULES AND ANY OTHER APPLICABLE
INDICATED LOADS.

2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL FOOTPRINT, WIRING CHANGES, ADDITIONAL CONTROL RELAYS, ETC.

OWNER, INCLUDING BUT NOT LIMITED TO DIFFERENCE IN MCC

NECESSARY DIFFERENCES WITH NO ADDITIONAL COST TO THE

SELECTED, CONTRACTOR IS RESPONSIBLE FOR PROVIDING FOR
THE OPERATION SHOWN HERE. IF ANOTHER MANUFACTURER IS
MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM

1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
# KEY NOTES:

FILTER
DV/DT

DI REMOTE
HSC-*
START

oox

HSA-*
OFF

LOCAL REMOTE
xoo

STOP
HSB-*

DI STOP

DI START

MODULE (HIM)

HUMAN INTERFACE

VFD KEYPAD/
VFD-*

LINE REACTOR

HIGH TEMPERATURE

LOW FLOW
SWITCH SHALL BE RESET THROUGH TO PCS.

FLOW ALARM SIGNAL SHALL BE SENT TO THE PLANT PLC. FLOW

SHUT OFF AFTER AN OPERATOR ADJUSTABLE TIMER AND A LOW
B. IN A LOW DISCHARGE FLOW CONDITION, THE EQUIPMENT SHALL BE SENT TO THE PLANT PLC.

SHALL SHUT OFF AND A HIGH TEMPERATURE ALARM SIGNAL SHALL A. IN A HIGH MOTOR TEMPERATURE CONDITION, THE EQUIPMENT HARDWIRED INTERLOCKS/OVERLOAD PROGRAMMED INTERLOCKS:

EQUIPMENT.

THE REMOTE POSITION, SCADA/HMI SHALL CONTROL THE
E. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN STARTED.

THE OFF POSITION, THE EQUIPMENT IS PROHIBITED FROM BEING D. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BY PRESSING THE STOP PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL STOP THE EQUIPMENT C. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN ADJUSTED USING THE SPEED POTENTIOMETER.

THE LOCAL POSITION, THE SPEED OF THE EQUIPMENT SHALL BE B. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BY PRESSING START PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL START THE EQUIPMENT A. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN

1. HARDWIRED CONTROLS:

P
lotD
ate: 06-APR
-2023
7:20:10
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N003.dgn
06N03
CONTROL SCHEMATIC 3
BAL
sshepard
149
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:25:15-06'00'
200

Page 414 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
120VAC
CR3-*
CR

RUNNING
VFD
4 TAG LOOP REFERENCE DWG.
91N01
* = 91100 PMP-91100 91N01

PAU PUMP
HSS-*
SPEED

DI
DI

POWER
FSL-*

ETHERNET
IP
DI
LSL-*
VFD-*
6 GENERAL NOTES:
# KEY NOTES:

SPEED
LOCAL
TSH-*
CR3-* MWH-*

MODULE (HIM)

HUMAN INTERFACE

VFD KEYPAD/

DI
LSHH-*
TM
GND
MOV
480V
M PMP-*
FILTER
DV/DT
CONVERTER MODULES AS NEEDED FOR FUNCTIONALITY SHOWN.

3. PROVIDE EXPANSION MODULES AND ANY OTHER APPLICABLE
INDICATED LOADS.

2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL FOOTPRINT, WIRING CHANGES, ADDITIONAL CONTROL RELAYS, ETC.

OWNER, INCLUDING BUT NOT LIMITED TO DIFFERENCE IN MCC

NECESSARY DIFFERENCES WITH NO ADDITIONAL COST TO THE

SELECTED, CONTRACTOR IS RESPONSIBLE FOR PROVIDING FOR
THE OPERATION SHOWN HERE. IF ANOTHER MANUFACTURER IS
MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM

1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED

DI REMOTE
HSC-*
START

oox

HSA-*
OFF

LOCAL REMOTE
xoo

STOP
HSB-*

DI STOP

DI START

LINE REACTOR

LOW FLOW

HIGH TEMPERATURE

LOW LEVEL

HIGH LEVEL
CAROUSEL PUMP NO. 3.

SIGNAL SHALL BE SENT TO THE PLANT PLC TO SHUT DOWN
D. IN HIGH HIGH LEVEL CONDITION, A HIGH HIGH LEVEL ALARM AND A LEVEL LOW SIGNAL SHALL BE SENT TO THE PLC.

C. IN LOW LEVEL CONDITION, THE EQUIPMENT SHALL SHUT OFF FLOW SWITCH SHALL BE RESET THROUGH THE PCS.

LOW FLOW ALARM SIGNAL SHALL BE SENT TO THE PLANT PLC.

SHUT OFF AFTER AN OPERATOR ADJUSTABLE TIMER AND A
B. IN A LOW DISCHARGE FLOW CONDITION, THE EQUIPMENT SHALL SHALL BE SENT TO THE PLANT PLC.

SHALL SHUT OFF AND A HIGH TEMPERATURE ALARM SIGNAL
A. IN A HIGH MOTOR TEMPERATURE CONDITION, THE EQUIPMENT HARDWIRED INTERLOCKS/OVERLOAD PROGRAMMED INTERLOCKS:

EQUIPMENT.

THE REMOTE POSITION, SCADA/HMI SHALL CONTROL THE
E. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BEING STARTED.

THE OFF POSITION, THE EQUIPMENT IS PROHIBITED FROM
D. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN EQUIPMENT BY PRESSING THE STOP PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL STOP THE
C. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN ADJUSTED USING THE SPEED POTENTIOMETER.

THE LOCAL POSITION, THE SPEED OF THE EQUIPMENT SHALL BE B. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN EQUIPMENT BY PRESSING START PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL START THE
A. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN

1. HARDWIRED CONTROLS:

P
lotD
ate: 06-APR
-2023
7:20:18
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N004.dgn
06N04
CONTROL SCHEMATIC 4
BAL
sshepard
150
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:26:40-06'00'
200

Page 415 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
M
M O.L.

HSA-*
LOCAL
OFF
REMOTE
xoo
HSB-*
STOP
HSC-*
START
AUX3-*
MS-*
MS-*
RUN
OUTPUT
oox
MS-*
M
3 O.L.'S
oox
HSAR-*
REMOTE
INPUT

AUX1-*

RUNNING
INPUT

AUX1-*
MS-*

SIG COM

TSH-*
INPUT

CR1-*
CR1-*
CR
TAG LOOP REFERENCE DWG.
5 CR1-*
MWH-*
AUX4-*
MS*-
* = 85104 PMP-85104 85N07
TSH-*
PMP-*
* = 87134 PMP-87134 87N01

RAPID MIX PUMP, SAMPLE PUMP
85N07, 87N01

HIGH TEMP
P
lotD
ate: 06-APR
-2023
7:20:25
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N005.dgn
06N05
CONTROL SCHEMATIC 5
BAL
151
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:26:56-06'00'
200

Page 416 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
M

WHERE INDICATED

REMOTE DISCONNECT
HSA-*
LOCAL
OFF
REMOTE
xoo
HSB-*
STOP
HSC-*
START
CR5-*
CR1-*
CR
TAG LOOP REFERENCE DWG.
6 MWH-*
* = 85106 BLO-85106 85N05
* = 85107 BLO-85107 85N05
TSH-*
BLO-*
85N05

AIR WASH BLOWERS
* = 85108 BLO-85108 85N05
MS-*
RUN
OUTPUT
oox
oox
HSAR-*
REMOTE
INPUT

AUX1-*

RUNNING
INPUT

SIG COM

TSH-*
INPUT

AUX2-*
INPUT
VCP-3

PRESS DIFF
CR2-*
CR
PDSH-*
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
M

WHERE INDICATED

REMOTE DISCONNECT
M O.L.

FAN-*
CR1-* CR2-* CR3-*
xoo
CR4-*
CR
INPUT

CR3-*
CR
MS-*
M
3 O.L.'S
MS-*
RUN
OUTPUT

AUX1-*

RUNNING
INPUT

VCP-3
AUX1-*
MS-*
TAG LOOP REFERENCE DWG.

FAN-85109 85N05
FAN-85110 85N05
FAN-85111 85N05
7 85N05

AIR WASH BLOWER FANS
* = 85109, **=85106
* = 85110, **=85107
* = 85111, **=85108
AUX3-*
PSH-*
CR2-*
CR1-*
CR3-*

BLOWER FILTER

MOTOR TEMP

DISCHARGE PRESS

CR4-*

BLOWER STARTER

AIR WASH
CR4-**
120VAC

RUNNING
RVSS
RVSS
RUN
CR5-*
RVSS-*
CR6-*
CR
CR
CR5-*
CR6-*
CR6-*

STARTER
MOTOR

BLOWER FAN

AIR WASH
P
lotD
ate: 06-APR
-2023
7:20:33
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N006.dgn
06N06
CONTROL SCHEMATIC 6
BAL
152
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:27:15-06'00'
200

Page 417 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
POWER_QUALITY_METER
POWER QUALITY METER POWER MONITOR M500 (PM500)
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
A PH DEMAND CURRENT ü ü
B PH DEMAND CURRENT ü ü
C PH DEMAND CURRENT ü ü
3 PH AVG DEMAND CURRENT ü ü ü
WATTS ü ü ü
VARS ü ü ü
VA ü ü ü
VA DEMAND ü ü ü
W DEMAND ü ü ü
ENERGY ü ü ü
FREQUENCY ü ü
POWER FACTOR ü ü ü
CAROUSEL_PUMP

CAROUSEL PUMP - VFD
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
DCL_STRUCTURE_VALVE

MULTI-TURN ACTUATOR
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK MOTOR CURRENT ü ü ü
LOCAL ü
OFF ü ü
REMOTE ü
OPEN ü ü
CLOSE ü ü
STOP ü ü
RUNNING CLOSE ü
RUNNING OPEN ü
CLOSE LIMIT ü ü ü
OPEN LIMIT ü ü ü
INSTANTANEOUS TORQUE ü ü ü ü
TORQUE ALARM ü ü ü
HIGH MOTOR TEMPERATURE ü ü ü
WATCHDOG TIMER ü
BATTERY LOW ü
RECYCLED_PUMP

RECYCLED PUMP - VFD
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
HIGH DISCHARGE PRESSURE ü ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
AWT_CLARIFIER_FILTER
VCP-3
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK HANDSHAKING ü ü
ALL SETPOINTS ü ü
AWT CLARIFIER/FILTER 1 READY ü
AWT CLARIFIER/FILTER 2 READY ü
AWT CLARIFIER/FILTER 3 READY ü
AWT CLARIFIER/FILTER 4 READY ü
BACKWASH IN PROGRESS ü
FLUSH IN PROGRESS ü
AIR WASH BLOWER 1 MODE AUTO ü ü
AIR WASH BLOWER 1 MOTOR STATUS STOPPED ü ü
AIR WASH BLOWER 1 MOTOR STATUS RUNNING ü ü
AIR WASH BLOWER 2 MODE AUTO ü ü
AIR WASH BLOWER 2 MOTOR STATUS STOPPED ü ü
AIR WASH BLOWER 2 MOTOR STATUS RUNNING ü ü
AIR WASH BLOWER 3 MODE AUTO ü ü
AIR WASH BLOWER 3 MOTOR STATUS STOPPED ü ü
COAGULANT PUMP 1 STATUS RUNNING OUTPUT ü ü
COAGULANT PUMP 2 STATUS RUNNING OUTPUT ü ü
COAGULANT PUMP 3 STATUS RUNNING OUTPUT ü ü
WASTE GATE VALVE 1 MODE AUTO ü ü
WASTE GATE VALVE 1 MODE POSITION ü ü
BACKWASH VALVE 1 MODE AUTO ü ü
BACKWASH VALVE 1 MODE POSITION ü ü
AC AIR SCOUR VALVE 1 MODE AUTO ü ü
AC AIR SCOUR VALVE 1 MODE POSITION ü ü
WASTE GATE VALVE 2 MODE POSITION ü ü
BACKWASH VALVE 2 MODE POSITION ü ü
AC AIR SCOUR VALVE 2 MODE POSITION ü ü
EFFLUENT VALVE 2 MODE AUTO ü ü
EFFLUENT VALVE 2 MODE POSITION ü ü
AWT CLARIFIER/FILTER 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 3 MODE STATUS ü ü
INFLUENT VALVE 3 MODE AUTO ü ü
AIR VALVE 3 MODE AUTO ü ü
WASTE GATE VALVE 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 4 MODE SEMI-AUTO ü ü
EFFLUENT VALVE 1 MODE POSITION ü ü
AWT CLARIFIER/FILTER 4 MODE AUTO ü ü
AWT CLARIFIER/FILTER 4 MODE STATUS ü ü
INFLUENT VALVE 4 MODE AUTO ü ü
INFLUENT VALVE 4 MODE POSITION ü ü
AIR VALVE 4 MODE AUTO ü ü
AIR VALVE 4 MODE POSITION ü ü
WASTE GATE VALVE 4 MODE AUTO ü ü
WASTE GATE VALVE 4 MODE POSITION ü ü
BACKWASH VALVE 4 MODE AUTO ü ü
AC AIR SCOUR VALVE 4 MODE AUTO ü ü
AC AIR SCOUR VALVE 4 MODE POSITION ü ü
EFFLUENT VALVE 4 MODE AUTO ü ü
EFFLUENT VALVE 4 MODE POSITION ü ü
AWT CLARIFIER/FILTER 1 CALL RUN COMMAND ü
AWT CLARIFIER/FILTER 2 CALL RUN COMMAND ü
AWT CLARIFIER/FILTER 4 CALL RUN COMMAND ü
AWT CLARIFIER/FILTER 4 INLET FLOW ü ü ü ü
COAGULANT FEED PUMP 1 COMMAND SPEED ü
COAGULANT FEED PUMP 2 COMMAND SPEED ü
COAGULANT FEED PUMP 3 COMMAND SPEED ü
AWT CLARIFIER/FILTER 3 INLET FLOW ü ü ü ü
INFLUENT VALVE 3 MODE POSITION ü ü
WASTE GATE VALVE 3 MODE POSITION ü ü
BACKWASH VALVE 3 MODE AUTO ü ü
EFFLUENT VALVE 3 MODE POSITION ü ü
BACKWASH VALVE 4 MODE POSITION ü ü
AWT CLARIFIER/FILTER 1 MODE SEMI-AUTO ü ü
AWT CLARIFIER/FILTER 1 MODE AUTO ü ü
AWT CLARIFIER/FILTER 1 MODE STATUS ü ü
INFLUENT VALVE 1 MODE AUTO ü ü
INFLUENT VALVE 1 MODE POSITION ü ü
AIR VALVE 1 MODE AUTO ü ü
AIR VALVE 1 MODE POSITION ü ü
EFFLUENT VALVE 1 MODE AUTO ü ü
INFLUENT VALVE 2 MODE POSITION ü ü
BACKWASH VALVE 3 MODE POSITION ü ü
AC AIR SCOUR VALVE 3 MODE AUTO ü ü
AC AIR SCOUR VALVE 3 MODE POSITION ü ü
EFFLUENT VALVE 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE SEMI-AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE STATUS ü ü
INFLUENT VALVE 2 MODE AUTO ü ü
AIR VALVE 2 MODE AUTO ü ü
AIR VALVE 2 MODE POSITION ü ü
WASTE GATE VALVE 2 MODE AUTO ü ü
BACKWASH VALVE 2 MODE AUTO ü ü
AC AIR SCOUR VALVE 2 MODE AUTO ü ü
AWT CLARIFIER/FILTER 3 MODE SEMI-AUTO ü ü
AIR VALVE 3 MODE POSITION ü ü
AWT CLARIFIER/FILTER 3 CALL RUN COMMAND ü
BACKWASH STATION LOW LEVEL OUTPUT ü
BACKWASH STATION HIGH LEVEL OUTPUT ü
AWT CLARIFIER/FILTER 1 INLET FLOW ü ü ü ü
AWT CLARIFIER/FILTER 2 INLET FLOW ü ü ü ü
AIR WASH BLOWER 3 MOTOR STATUS RUNNING ü ü
PAU_PUMP

PAU PUMP - VFD
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
LOW LEVEL ü ü ü
HIGH MOISTURE DETECTION ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
P
lotD
ate: 06-APR
-2023
7:20:02
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
DKI

INSTRUMENTATION
8660F10 8660F1009N001.dgn
09N01

PCS I/O TABLES
BAL
153
M
Hood
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:43:30-06'00'
200

Page 418 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

PUMP STATION

TO CAROUSEL

FACILITY

FROM CHLORINATION
FV-60100
DCL STRUCTURE VALVE 1
5HP 480VAC 3PH
AE-60101
CHLORINE ANALYZER 4
0-10 MG/L
AE
60101

CHLORINE
AIT
60101
CB
60101
TM
120VAC-1P
PCM-70299
E
FV-60102
DCL STRUCTURE VALVE 2
5HP 480VAC 3PH

INJECTION STRUCTURE

FROM SODIUM BISULFATE
RIVER

TO RUSSIAN
EX- 42"
EX- 24" FE
EX- 42" RCP
P
O
W
ER
SOURC
E
FIELD
I/O
EX- 30" WSP
FV
60100
VAL
60100
A
60101
AI
CL
PLC-70299
E
DRAIN

REAGENT
DRAIN

PROCESS
PMP-60101

DCL CHLORINE SAMPLE PUMP

PMP
60101
E
M
PI-60101

PRESSURE INDICATOR
0-30 PSI
PI
60101

PRESSURE
FI
60101

CHLORINE
FI-60101

CHLORINE SAMPLE FLOW INDICATOR
0-500 ML/MIN
VAL
60102
FV
60102
TYP
*
NA090
CB
60100
TM
480VAC-3P
MCC70291
FVC
60100
EIP
PLC-70299
DCL_STRUCTURE_VALVE
CB
60102
TM
480VAC-3P
MCC70291
FVC
60102
EIP
PLC-70299
DCL_STRUCTURE_VALVE
PMP-60135

CHLORINE BASIN SAMPLE PUMP

DISC
60009
E
CB
60009
TM
480VAC-3P
MCC70291
E
HSG
60009
E OSC
HSA
60009
E LSR
FCV-60009

DCL STRUCT CHLORINE VALVE

E
D
HSAR
60009
DI
REMOTE
PLC-70299
E
ZSC
60009
DI
CLOSED
PLC-70299
E
ZSO
60009
DI
OPENED
PLC-70299
E
ZCO
60009
DO
OPEN
PLC-70299
E
ZCC
60009
DO
CLOSE
PLC-70299
E
M
DRAIN

PROCESS
PMP
60135
E
FCV
60009
E
VAL
60009
E
LCP
60009
E
HSA
60009
E LSR
HSG
60009
E OSC
ZSOC
60009
E

CHLORINE BASIN
1 1
# KEY NOTES:

AND BE INSTALLED IN THE EXISTING ENCLOSURE.

2. THE NEW ANALYZER SHALL REPLACE THE EXISTING ANALYZER ETHERNET SWITCH IN PANEL PLC-70299.

1. ETHERNET CONNECTION SHALL BE CONNECTED TO THE EXISTING DISC
60100
HSG
60100
OSC
HSA
60100
LSR
DISC
60102
HSG
60102
OSC
HSA
60102
LSR
ZSOC
60100
HSG
60100
OSC
HSA
60100
LSR
LCP
60100
ZSOC
60102
HSG
60102
OSC
HSA
60102
LSR
LCP
60102
E
D
E
D
2 P
lotD
ate: 06-APR
-2023
7:17:56
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
60N01

DECHLORINATION STRUCTURE P&ID
8660F1060N001.dwg
lbordelon
8660F10
154
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:43:46-06'00'
200

Page 419 of 599 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PIPE - SEGMENT 2

FROM CHLORINE CONTACT
LE-80100
STRUCT 80 LEVEL
0-18 FT
LE
80100

ULTRASONIC
LIT
80100
TYP
*
NL175
P
O
W
ER
SOURC
E
FIELD
I/O
L
80100
AI
PLC-70299

PUMP STATION
TO AWT
LSL
80011
E
LE-80011

LOW LEVEL SWITCH
LE
80011

E FLOAT
MM
FE-80002

RECLAIMED WATER FLOW TRANSMITTER
FE
80002

E MAGNETIC
FIT
80002
E
CB
80002
TM
120VAC-1P
PCM
E
LSL
80012
E
LE-80012

LOW LEVEL SWITCH
LE
80012

E FLOAT
LSL
80013
E
LE-80013

LOW LEVEL SWITCH
LE
80013

E FLOAT
96" SE

PUMP STATION

TO CAROUSEL
17 91N01
80N01

PUMP STATION

FROM PAU

WATER FILTER

TO RECLAIMED
30" FE
42" SE
6"RC
W
6"RC
W
6"RC
W
8" RCW
PMP
80111
E
PMP-80111
RECLAIMED WATER FILTER FEED PUMP 1

PMP
80112
E
PMP-80112
RECLAIMED WATER FILTER FEED PUMP 2

PMP
80113
E
PMP-80113
RECLAIMED WATER FILTER FEED PUMP 3

16" RW
P
lotD
ate: 06-APR
-2023
7:18:03
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
80N01
STRUCTURE 80 P&ID
8660F10 8660F1080N001.dwg
155
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:44:03-06'00'
200

Page 420 of 599 ends
← All documents from this meeting