2. 3.
4. 5.
8. 9.
10. 11.
1. 2.
12. 13.
14. 15.
DIFFUSERS AND GRILLS TO MATCH COLOR OF SURFACE AT WHICH THEY ARE MOUNTED, UNLESS OTHERWISE NOTED.
PLUMBING, ELECTRICAL, AND SPRINKLER EQUIPMENT, IF REQUIRED, TO BE PAINTED TO MATCH COLOR OF ADJACENT SURFACE.
FLOOR FINISH TO CONTINUE UNDER MILLWORK WHERE FLOOR IS VISIBLE.
SILICONE SEALANT AT GLAZING TO BE CLEAR, UNLESS OTHERWISE NOTED.
TRANSITION OF FLOOR MATERIALS OCCURRING IN OPENINGS WITH DOORS TO BE LOCATED UNDER THE CENTER OF THE DOOR IN THE CLOSED POSITION. TRANSITION OF FLOOR MATERIAL OCCURRING WITH NO DOOR TO BE LOCATED TO ALIGN WITH THE FACE OF THE PARTITION, U.O.N ALL WALL AND CEILING FINISHES SHALL COMPLY WITH CRC 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY. ALL FINISHES MUST COMPLY WITH ALL APPLICABLE FIRE, LIFE SAFETY, AND BUILDING CODES.
PROVIDE REINFORCEMENT FOR GRAB BARS IN AT LEAST ONE BATHROOM [CRC SECTION R327.1.1, AGING-IN-PLACE DESIGN AND FALL PREVENTION]
REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY.
REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER OR OTHER MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES AND 39 ¼” INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING.
WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL.
SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED.
BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT
FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM.
PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO SHELVING AND BATHROOM FIXTURES.
PROVIDE REQUIRED CLEARANCES FOR BATHROOM FIXTURES, INCLUDING WATER CLOSETS AND SHOWER COMPARTMENTS AS ILLUSTRATED ON SHEET A5.1 [CPC 402.5 AND CPC 408]
SEE DETAILS FOR LOCATIONS OF MISCELLANEOUS IRON AND STEEL WORK, INCLUDING BUT NOT LIMITED TO ASSORTED CLIPS, BRACKETS, ANGLES, STRAPS, AND POST ANCHORS. FURNISH AND
INSTALL ALL SUCH ITEMS NECESSARY TO PROVIDE A COMPLETE INSTALLATION, WHETHER OR NOT SPECIFICALLY DETAILED OR NOTED ON THE DRAWINGS. ALL EXTERIOR METAL AND HARDWARE IS TO BE GALVANIZED. STEEL IS TO COMPLY WITH ASTM A3.
ATTIC ACCESS [CRC R807.1]
BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENINGS TO ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES OR GREATER OVER AN AREA OF NOT LESS THAN 30 SF. THE VERTICAL HEIGHT SHALL BE
MEASURED FROM THE TOP OF THE CEILING FRAMING MEMBERS TO THE UNDERSIDE OF THE
ROOF FRAMING MEMBERS
THE ROUGH-FRAMED OPENING SHALL BE NOT LESS THAN 22 IN BY 30 IN AND SHALL BE LOCATED IN A HALLWAY OR OTHER LOCATION WITH READY ACCESS. WHERE THE ACCESS IS LOCATED IN A CEILING, MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE 30
IN AT SOME POINT ABOVE THE ACCESS MEASURED VERTICALLY FROM THE BOTTOM OF CEILING FRAMING MEMBERS.
WOOD SOFFIT/CEILING, SIDING & TRIM
ALL NAILS, FASTENERS AND HARDWARE MUST BE STAINLESS STEEL OR HOT-DIPPED GALVANIZED.
STAPLES ARE NOT PERMITTED.
PROVIDE A WATER-RESISTIVE BARRIER APPLIED OVER STUD OR SHEATHING OF ALL EXTERIOR
WALLS WITH FLASHING, IN SUCH A MANNER AS TO PROVIDE A CONTINUOUS BARRIER BEHIND THE EXTERIOR WALL VENEER [CRC SECTION R703.2]
APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED SHINGLE-FASHION IN A MANNER
TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENT AND COMPLY WITH CRC SECTION 703.4.
FLASHING AND SHEET METAL
ALL FLASHING AND COUNTER FLASHING SHALL BE GALVANIZED AND INSTALLED PER SMACNA STANDARDS. ALL PROPOSED FLASHING AND SHEET METAL MATERIALS, GAUGE, AND INSTALLATION IS TO BE IN ACCORDANCE WITH SMACNA MANUAL STANDARDS.
1. 2.
3. A.
B.
a.
b.
C.
a.
b.
D.
a.
b.
1. 2.
INSTALL CLASS A ROOF ASSEMBLY PER SPECIFICATION BELOW. (CLASS A ROOF ASSEMBLY SHALL BE INSTALLED. IF THE APPLICANT DEVIATES FROM THE ROOF SPECIFICATIONS THE APPLICANT
SHALL PROVIDE A COPY OF THE ICC/UL LISTING)
ROOF COVERING SHALL COMPLY WITH CRC R902 AND CRC R905.
ROOF MATERIAL SPECIFICATIONS
ALL ROOFING MATERIALS TO BE INSTALLED PER MANUFACTURER ’S SPECIFICATIONS ASPHALT SHINGLE ROOF - CERTAINTEED (ICC-ES ER ESR-3537) 2”/12” SLOPE (17%) MINIMUM
FOR ROOF SLOPES 2 ”/12” (17%) UP TO 4”/12” (33%), DOUBLE UNDERLAMENT APPLICATION IS REQUIRED [CRC R905.1.1]
STANDING SEAM METAL ROOF - METAL SALES MAGNA-LOC (ICC ES REPORT ESR-2385) ¼”/12” SLOPE (2%) MINIMUM
24 GA
CONCRETE TILE ROOF - EAGLE ROOF PRODUCTS (IAMP UES-ER 1900) 2 ½”/12” SLOPE (25%) MINIMUM
FOR ROOF SLOPES 2 ½”/12” (2%) UP TO 4”/12” (33%), INSTALL DOUBLE UNDERLAYMENT APPLICATION [CRC R905.3.3]
4. ROOF GUTTERS AND DOWNSPOUTS SHALL BE INSTALLED AND DESIGNED IN ACCORDANCE WITH SMACNA MANUAL. SIZE AS REQUIRED TO HANDLE THE AMOUNT OF ROOF WATER FOR MAXIMUM STORMS.
5. PROVIDE PLAIN RECTANGULAR ROOF GUTTER.
6. GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER IN HIGH FIRE SEVERITY ZONES.
7. ROOF VENTS
ROOF VENTS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS OPENINGS FOR VENTILATION HAVING A LEAST DIMENSION LARGER THAN 1/4 INCH SHALL BE
PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVING A LEAST DIMENSION OF NOT LESS THAN 1/16 INCH AND NOT MORE THAN 1/4 INCH.
GENERAL ARCHITECTURAL NOTES
GENERAL ARCHITECTURAL ROOF NOTES
ABBREVIATIONS
1. 2.
3. 4.
8. FLASHINGS SHALL BE INSTALLED IN A MANNER THAT PREVENTS MOISTURE FROM ENTERING THE
WALL AND ROOF THROUGH JOINTS IN COPINGS, THROUGH MOISTURE PERMEABLE MATERIALS AND
AT INTERSECTIONS WITH WALLS AND OTHER PENETRATIONS THROUGH THE ROOF PLANE PER CRC SECTION 903.2.
9. NOT LESS THAN 1-INCH SPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING AND AT THE LOCATION OF VENTS [CRC SECTION R806.3].
10. INSTALL INSULATION PER CRC SECTION R806.5:
(REFER TO DETAILS A, B, AND C ON SHEET A5.2)
WHERE ONLY AIR-IMPERMEABLE INSULATION IS PROVIDED, IT SHALL BE APPLIED IN DIRECT CONTACT WITH UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING.
WHERE AIR-PERMEABLE INSULATION IS INSTALLED DIRECTLY BELOW THE STRUCTURAL
SHEATHING, RIGID BOARD OR SHEET INSULATION SHALL BE INSTALLED DIRECTLY ABOVE THE
STRUCTURAL ROOF SHEATHING IN ACCORDANCE WITH R-VALUES BASED ON CLIMATE ZONE PER TABLE R806.5 FOR CONDENSATION CONTROL.
WHERE BOTH AIR-IMPERMEABLE INSULATION AND AIR-PERMEABLE INSULATION ARE PROVIDED,
THE AIR-IMPERMEABLE INSULATION SHALL BE APPLIED IN DIRECT CONTACT WITH THE
UNDERSIDE OF THE STRUCTURAL ROOF SHEATHING IN ACCORDANCE WITH R-VALUES BASED ON CLIMATE ZONE PER TABLE R806.5 FOR CONDENSATION CONTROL. THE AIR-PERMEABLE
INSULATION SHALL BE INSTALLED DIRECTLY UNDER THE AIR-IMPERMEABLE INSULATION
ALTERNATIVELY, SUFFICIENT RIGID BOARD OR SHEET INSULATION SHALL BE INSTALLED
DIRECTLY ABOVE THE STRUCTURAL ROOF SHEATHING TO MAINTAIN THE MONTHLY AVERAGE TEMPATURE OF THE UNDERSIDE OF THE STRUCTURAL ROOF SHEATHIGN ABOVE 45 DEG F. FOR CLACULATION PURPOSES, AN INTERIOR AIR TEMPATURE OF 68 DEG IS ASSUMED AND THE
EXTERIOR AIR TEMPERATURE IS ASSUMED TO BE THE MONTHLY AVERAGE OUTSIDE AIR TEMEPRATURE OF THE THREE COLDEST MONTHS.
GENERAL ARCHITECTURAL ROOF NOTES CONTINUED
GENERAL FIRE NOTES
1. 2.
3. 4.
WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL ASSEMBLIES, THE FIRE RATING OF
THOSE ASSESMBLIES SHALL BE MAINTAINED
AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE RATED PARTITIONS, PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING.
SEE SHEET A-6.1 FOR FIRE RATED GLAZING REQUIREMENTS.
THE ADU SHALL COMPLY WITH CHAPTER 7A MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE OF THE 2022 CALIFORNIA BUILDING CODE IF IT IS IN THE VERY HIGH FIRE HAZARD SEVERITY ZONE (VHFHSZ).
1. 2.
3. 4.
1. 2.
3. 5.
1. 2.
3. 6.
1. 2.
3. 7.
8. 1.
2. 3.
4. 5.
6. 7.
1. 2.
3. 4.
5. 6.
REQUIREMENTS OF CHAPTER 7A OF THE 2022 CALIFORNIA BUILDING CODE INCLUDE:
705A.2 ROOF COVERINGS. WHERE THE ROOF PROFILE HAS AN AIRSPACE UNDER THE ROOF COVERING, INSTALLED OVER A COMBUSTIBLE DECK, A 72 LB. (32.7 KG) CAP SHEET COMPLYING WITH ASTM D3909 STANDARD SPECIFICATION FOR "ASPHALT ROLLED ROOFING (GLASS FELT) SURFACED WITH MINERAL GRANULES," SHALL BE INSTALLED OVER THE ROOF DECK. BIRD STOPS SHALL BE USED AT THE EAVES WHEN THE PROFILE FITS. TO PREVENT DEBRIS AT THE EAVE. HIP AND RIDGE CAPS SHALL BE MUDDED IN TO PREVENT INTRUSION OF FIRE OR EMBERS. EXCEPTION:
CAP SHEET IS NOT REQUIRED WHEN NO LESS THAN 1" OF MINERAL WOOL BOARD OR OTHER
NONCOMBUSTIBLE MATERIAL IS LOCATED BETWEEN THE ROOFING MATERIAL AND WOOD FRAMING OR DECK. ALTERNATELY, A CLASS A FIRE RATED ROOF UNDERLAYMENT, TESTED IN ACCORDANCE WITH ASTM E108, SHALL BE PERMITTED TO BE USED. IF THE SHEATHING CONSISTS
OF EXTERIOR FIRE-RETARDANT TREATED WOOD, THE UNDERLAYMENT SHALL NOT BE REQUIRED TO COMPLY WITH A CLASS A CLASSIFICATION. BIRD STOPS SHALL BE USED AT THE EAVES WHEN THE PROFILE FITS, TO PREVENT DEBRIS AT THE EAVE. HIP AND RIDGE CAPS SHALL BE MUDDED IN TO PREVENT INTRUSION OF FIRE OR EMBERS.
705.A.3 ROOF VALLEYS. WHERE VALLEY FLASHING IS INSTALLED, THE FLASHING SHALL BE NOT LESS THAN 0.019-INCH NO. 26 GAGE GALVANIZED SHEET CORROSION-RESISTANT METAL INSTALLED OVER NOT LESS THAN ONE LAYER OF MIN. 72 POUND MINERAL-SURFACED NON PERFORATED CAP SHEET COMPLYING WITH ASTM D 3909. AT LEAST 36-INCH -WIDE RUNNING THE FULL LENGTH OF THE VALLEY.
705A.4 ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER.
706A.2 VENTILATION OPENINGS SHALL BE FULLY COVERED WITH WILDFIRE FLAME AND EMBER
RESISTANT VENTS APPROVED AND LISTED BY THE CALIFORNIA STATE FIRE MARSHAL, OR WUI VENTS TESTED TO ASTM E2886 AND LISTED, BY COMPLYING WITH ALL OF THE FOLLOWING REQUIREMENTS:
THERE SHALL BE NO FLAMING IGNITION OF THE COTTON MATERIAL DURING THE EMBER
INTRUSION TEST
THERE SHALL BE NO FLAMING IGNITION DURING THE INTEGRITY TEST PORTION OF THE FLAME
INTRUSION TEST
THE MAXIMUM TEMPERATURE OF THE UNEXPOSED SIDE OF THE VENT SHALL NOT EXCEED 662 F
706A.2.1 VENTS THAT ARE INSTALLED ON A SLOPED ROOF, SUCH AS DORMER VENTS, SHALL COMPLY WITH ALL THE FOLLOWING:
VENTS SHALL BE COVERED WITH A MESH WHERE THE DIMENSIONS OF THE MESH THEREIN SHALL BE A MINIMUM OF 1/16 - INCH AND SHALL NOT EXCEED 1/8 - INCH IN DIAMETER
THE MESH MATERIAL SHALL BE NONCOMBUSTIBLE
THE MESH MATERIAL SHALL BE CORROSION RESISTANT.
707A.3 EXTERIOR WALLS COVERINGS. THE EXTERIOR WALL COVERING SHALL COMPLY WITH ONE
OR MORE OF THE FOLLOWING REQUIREMENTS, EXCEPT AS PERMITTED FOR EXTERIOR WALL ASSEMBLIES COMPLYING WITH SECTION 707A.4:
NONCOMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 704A.2.
FIRE-RETARDANT-TREATED WOOD. THE FIRE-RETARDANT-TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2. 707A.3.1 EXTENT OF EXTERIOR WALL COVERING. EXTERIOR WALL COVERINGS SHALL EXTEND FROM THE TOP OF THE FOUNDATION TO THE ROOF AND TERMINATE AT 2" NOMINAL SOLID WOOD
BLOCKING BETWEEN RAFTERS AT ALL ROOF OVERHANGS, OR IN THE CASE OF ENCLOSED EAVES, TERMINATE AT THE ENCLOSURE.
707A.4 EXTERIOR WALL ASSEMBLIES. EXTERIOR WALL ASSEMBLIES OF BUILDINGS OR
STRUCTURES SHALL BE CONSTRUCTED USING ONE OR MORE OF THE FOLLOWING METHODS, UNLESS THEY ARE COVERED BY AN EXTERIOR WALL COVERING COMPLYING WITH SECTION 707A.3:
ASSEMBLY OF SAWN LUMBER OR GLUE LAMINATED WOOD WITH THE SMALLEST MINIMUM NOMINAL DIMENSION OF 4 INCHES. SAWN OR GLUE-LAMINATED PLANKS SPLINED, TONGUEAND-GROVE , OR SET CLOSE TOGETHER AND WELL SPIKED.
LOG WALL CONSTRUCTION ASSEMBLY
ASSEMBLY THAT HAS BEEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES FOR A 10 MINUTE DIRECT FLAME CONTACT EXPOSURE SET FORTH IN ASTM E2707 WITH THE CONDITIONS OF ACCEPTANCE SHOWN IN SECTION 707A.4.1.
ASSEMBLY THAT MEET THE PERFORMANCE CRITERIA IN ACCORDANCE WITH THE TEST
PROCEDURES FOR A TEN MINUTE DIRECT FLAME CONTACT EXPOSURE TEST SET FORTH IN SFM STANDARD 12-7A-1
ASSEMBLY SUITABLE FOR EXTERIOR FIRE EXPOSURE WITHA 1-HOUR FIRE RESISTANCE RATING, RATED FROM THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL263
ASSEMBLY SUITABLE FOR EXTERIOR FIRE EXPOSURE CONTAINING ONE LAYER OF 5/8 -INCH
TYPE X GYPSUM SHEATHING APPLIED BEHIND THE EXTERIOR WALL COVERING OR CLADDING ON THE EXTERIOR SIDE OF THE FRAMING.
ASSEMBLY SUITABLE FOR EXTERIOR EXPOSURE CONTAINING ANY OF THE GYPSUM PANEL
AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUEL AS COMPLYING WITH A1-HOUR FIRE-RESISTANCE RATING, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263
9. 707A.5 OPEN ROOF EAVES. THE EXPOSED ROOF DECK ON THE UNDERSIDE OF ENCLOSED ROOF EAVES SHALL CONSIST OF ONE OR MORE OF THE FOLLOWING:
NON COMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AN SHALL MEET THE REQUIREMENTS OF SECTION 704A.2 FIRE-RETARDANT-TREATED WOOD. THE FIRE-RETARDANT-TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2 MATERIALS APPROVED FOR NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION ON THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263
ONE LAYER OF 5/8" TYPE X GYPSUM SHEATHING APPLIES BEHIND AN EXTERIOR COVERING ON THE UNDERSIDE EXTERIOR OF THE ROOFDECK.
THE EXTERIOR PORTION A 1- HOUR FIRE RESISTIVE EXTERIOR ASSEMBLY, APPLIES AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, APPLIED TO THE UNDERSIDE OF THE
ROOF DECK DESIGNED FOR THE EXTERIOR FIRE EXPOSURE, INCLUDING ASSEMBLES USING
THE GYPSUM PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DEIGN MANUAL. EXCEPTION TO SECTION 707A.5: THE FOLLOWING MATERIALS DO NOT REQUIRE PROTECTION: FASCIA AND OTHER ARCHITECTURAL TRIM BOARDS
1. 2.
3. 4.
5. 6.
7. 8.
1. 2.
3. 4.
5. 6.
7. 8.
1. 2.
3. 4.
5. 6.
7. 8.
1. 2.
3. 4.
5. 6.
7. 8.
1. 2.
3. 4.
5. 6.
7. 8.
10. 707A.6 ENCLOSED ROOF EAVES AND ROOF EAVE SOFFITS. THE EXPOSED UNDERSIDE OF ENCLOSED
ROOF EAVES HAVING EITHER A BOXED-IN ROOF EAVE SOFFIT WITH A HORIZONTAL UNDERSIDE,OR
SLOPING RAFTER TAILS WITH AN EXTERIOR COVERING APPLIED TO THE UNDERSIDE OF THE RAFTER TAILS, SHALL BE PROTECTED BY ONE OR MORE OF THE FOLLOWING:
NONCOMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 704A.2 FIRE-RETARDANT-TREATED-WOOD. THE FIRE-RETARDANT TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2 MATERIALS APPROVED FOR NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION ON THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 ONE LAYER OF 5/8" TYPE X GYPSUM SHEATHING APPLIED BEHIND AN EXTERIOR COVERING ON THE UNDERSIDE OF FLOOR PROJECTION.
THE EXTERIOR PORTION A 1- HOUR FIRE RESISTIVE EXTERIOR ASSEMBLY, APPLIED TO THE
UNDERSIDE OF THE RAFTER TAIS OR SOFFIT, INCLUDING ASSEMBLES USING THE GYPSUM
PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE
DESIGN MANUAL
BOXED-IN ROOF EAVE SOFFIT ASSEMBLIES WITH A HORIZONTAL UNDERSIDE THAT MEET THE PERFORMANCE CRITERIA IN SECTION 707A.11 WHEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN ASTM E2957
BOXED-IN ROOF EAVE SOFFIT ASSEMBLIES WITH A HORIZONTAL UNDERSIDE THAT MEET THE PERFORMANCE CRITERIA IN SECTION 707A.11 WHEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN SFM STANDARD 12-7A-3 EXCEPTION TO SECTION 707A.6: THE FOLLOWING MATERIALS DO NOT REQUIRE PROTECTION: FASCIA AND OTHER ARCHITECTURAL TRIM BOARDS.
11. 707A.7 EXTERIOR PORCH CEILINGS. THE EXPOSED UNDERSIDE OF THE EXTERIOR PORCH CEILINGS SHALL BE PROTECTED BY ONE OF THE FOLLOWING:
NON COMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 704A.2 FIRE-RETARDANT-TREATED-WOOD. THE FIRE-RETARDANT TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2 MATERIALS APPROVED FOR NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION ON THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 ONE LAYER OF 5/8" TYPE X GYPSUM SHEATHING APPLIED BEHIND THE EXTERIOR COVERING OR CLADDING ON THE UNDERSIDE OF THE RAFTER TAILS OR SOFFIT.
THE EXTERIOR PORTION A 1- HOUR FIRE RESISTIVE EXTERIOR ASSEMBLY, AS TESTED IN ACCORDANCE WITH ASTM E119, APPLIED TO THE UNDERSIDE OF THE CEILING ASSEMBLY,
INCLUDING ASSEMBLES USING THE GYPSUM PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL.
PORCH CEILING ASSEMBLIES WITH A HORIZONTAL UNDERSIDE THAT MEET THE PERFORMANCE CRITERIA IN SECTION 707A.11 WHEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN ASTM E2957
PORCH CEILING ASSEMBLIES WITH A HORIZONTAL UNDERSIDE THAT MEET THE PERFORMANCE CRITERIA IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN SFM STANDARD 12-7A-3 EXCEPTION TO SECTION 707A.7: ARCHITECTURAL TRIM BOARDS DO NOT REQUIRE PROTECTION
12. 707A.8 FLOOR PROJECTIONS. THE EXPOSED UNDERSIDE OF A CANTILEVER FLOOR PROJECTION
WHERE A FLOOR ASSEMBLY EXTENDS OVER AN EXTERIOR WALL SHALL BE PROTECTED BY ON OF THE FOLLOWING:
NONCOMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 704A.2 FIRE-RETARDANT-TREATED-WOOD. THE FIRE-RETARDANT TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2 MATERIALS APPROVED FOR NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION ON THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 ONE LAYER OF 5/8" TYPE X GYPSUM SHEATHING APPLIED BEHIND AND EXTERIOR COVERING ON
THE UNDERSIDE OF THE CEILING
THE EXTERIOR PORTION A 1- HOUR FIRE RESISTIVE EXTERIOR ASSEMBLY, AS TESTED IN ACCORDANCE WITH ASTM E119, APPLIED TO THE UNDERSIDE OF THE CEILING ASSEMBLY,
INCLUDING ASSEMBLES USING THE GYPSUM PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL.
THE UNDERSIDE OF A FLOOR PROJECTIONS ASSEMBLY THAT MEETS THE PERFORMANCE CRITERIA IN SECTION 707A.10 WHEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN ASTM E2957.
THE UNDERSIDE OF A FLOOR PROJECTIONS ASSEMBLY THAT MEETS THE PERFORMANCE CRITERIA IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN THE SFM STD 12-7A-3.
EXCEPTION TO SECTION 707A.8: ARCHITECTURAL TRIM BOARDS DO NOT REQUIRE PROTECTION
13. 707A.9 UNDERFLOOR PROTECTION. THE UNDERFLOOR AREA OF ELEVATED OR OVERHANGING
BUILDINGS SHALL BE ENCLOSED TO GRADE IN ACCORDANCE WITH THE REQUIREMENTS OF
THIS CHAPTER OR THE UNDERSIDE OF THE EXPOSED UNDERFLOOR SHALL BE PROTECTED BY ONE OR MORE OF THE FOLLOWING:
NONCOMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 704A.2 FIRE-RETARDANT-TREATED-WOOD. THE FIRE-RETARDANT TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2 MATERIALS APPROVED FOR NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION ON THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 ONE LAYER OF 5/8" TYPE X GYPSUM SHEATHING APPLIED BEHIND AND EXTERIOR COVERING ON
THE UNDERSIDE OF THE FLOOR PROJECTION
THE EXTERIOR PORTION A 1- HOUR FIRE RESISTIVE EXTERIOR ASSEMBLY, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, APPLIED TO THE UNDERSIDE OF THE FLOOR,
INCLUDING ASSEMBLES USING THE GYPSUM PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL.
THE UNDERSIDE OF A FLOOR ASSEMBLY THAT MEETS THE PERFORMANCE CRITERIA IN SECTION 707A.11 WHEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN ASTM E2957.
THE UNDERSIDE OF A FLOOR ASSEMBLY THAT MEETS THE PERFORMANCE CRITERIA IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN SFM STANDARD 12-7A-3. EXCEPTION TO SECTION 707A.9: STRUCTURAL COLUMNS AND BEAMS DO NOT REQUIRE PROTECTION WHEN
CONSTRUCTED WITH SAWN LUMBER OR GLUE-LAMINATED WOOD WITH THE SMALLEST MINIMUM NOMINAL DIMENSION OF 4 INCHES. SAWN OR GLUE-LAMINATED PLANKS SHALL BE SPLINED, TONGUE-AND-GROOVE, OR SET CLOSE TOGETHER AND WELL SPIKED.
14. 707A.10 UNDERSIDE OF APPENDAGES. WHEN REQUIRED BY THE ENFORCING AGENCY THE
UNDERSIDE OF OVERHANGING APPENDAGES SHALL BE ENCLOSED TO GRADE IN ACCORDANCE
WITH THE REQUIREMENTS OF THIS CHAPTER OR THE UNDERSIDE OF THE EXPOSED UNDER FLOOR SHALL CONSIST OF ONE OF THE FOLLOWING:
NONCOMBUSTIBLE MATERIAL
IGNITION- RESISTANT MATERIAL. THE IGNITION-RESISTANT MATERIAL SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 704A.2 FIRE-RETARDANT-TREATED-WOOD. THE FIRE-RETARDANT TREATED WOOD SHALL BE LABELED FOR EXTERIOR USE AND SHALL MEET THE REQUIREMENTS OF SECTION 2303.2 MATERIALS APPROVED FOR NOT LESS THAN 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION ON THE EXTERIOR SIDE, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263 ONE LAYER OF 5/8" TYPE X GYPSUM SHEATHING APPLIED BEHIND THE EXTERIOR COVERING ON
THE UNDERSIDE OF THE APPENDAGE PROJECTION
THE EXTERIOR PORTION A 1- HOUR FIRE RESISTIVE EXTERIOR ASSEMBLY, AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, APPLIED TO THE UNDERSIDE OF THE APPENDAGE,
INCLUDING ASSEMBLES USING THE GYPSUM PANEL AND SHEATHING PRODUCTS LISTED IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL.
THE UNDERSIDE OF AN APPENDAGE ASSEMBLY THAT MEETS THE PERFORMANCE CRITERIA IN SECTION 707A.11 WHEN TESTED IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN ASTM E2957.
THE UNDERSIDE OF AN APPENDAGE ASSEMBLY THAT MEETS THE PERFORMANCE CRITERIA IN ACCORDANCE WITH THE TEST PROCEDURES SET FORTH IN SFM STANDARD 12-7A-3.EXCEPTION TO SECTION 707A.10: STRUCTURAL COLUMNS AND BEAMS DO NOT REQUIRE PROTECTION WHEN
CONSTRUCTED WITH SAWN LUMBER OR GLUE-LAMINATED WOOD WITH THE SMALLEST MINIMUM NOMINAL DIMENSION OF 4 INCHES. SAWN OR GLUE-LAMINATED PLANKS SHALL BE SPLINED, TONGUE-AND-GROOVE, OR SET CLOSE TOGETHERAND WELL SPIKED.
GENERAL FIRE NOTES CONTINUED
ARCHITECTURAL SYMBOLS
CALLOUT PLAN,
SECTION OR DETAIL
#
BUILDING SECTION
ELEVATIONS
VIEW TITLE
# SCALE:
VIEW CALLOUT
COLUMN GRID #
#
DOOR TAG - SEE
SCHEDULE
##.## KEYNOTE
DENOTES ABOVE,
BELOW, OR BEHIND
# WINDOW TYPE
LEVEL LINE
CENTER LINE
#
#
#
GLAZING
#
#
Sheet #
D
C
B
A
1 2 3 4 5
1 2 3 4 5
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS
A-1.0
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
ABB DESCRIPTION
__________ A __________
& AND
< ANGLE
@ AT
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
APPROX APPROXIMATE(LY)
ARCH ARCHITECT OR ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING MATERIAL
AVG AVERAGE
__________ B __________
BC BASE CABINET
BD BOARD
BLDG BUILDING
BO BOTTOM OF
__________ C __________
C/ CENTER OF
CAB CABINET
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
__________ D __________
DIA DIAMETER
DIM DIMENSION
DN DOWN
DW DISHWASHER
DWG DRAWING
__________ E __________
E EAST
EA EACH
ELEC ELECTRICAL
EMER EMERGENCY
ENCL ENCLOSE(URE)
EP ELECTRICAL PANEL
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
EXT EXTERIOR
__________ F __________
F/F FACE TO FACE
FL FLOOR
FP FIRE PROTECTION
FPRF FIREPROOF(ING)
FR FIRE RATED OR FRAME
FT FOOT/FEET
__________ G __________
GA GAUGE
GL GLASS OR GLAZING
GRD GROUND
GWB GYPSUM WALL BOARD
__________ H __________
HB HOSE BIBB
HDW HARDWARE
HM HOLLOW METAL
HOR HORIZONTAL
HP HIGH POINT
HTR HEATER
__________ I __________
ID INSIDE DIAMETER
IN INCH(ES)
INT INTERIOR
__________ J __________
JB JAMB
JST JOIST
JT JOINT
__________ L __________
LAM LAMINATE
LAN LOCAL AREA NETWORK CONNECTION
LAV LAVATORY
LB POUND
LF LINEAL FOOT
LP LOW POINT
LTL LINTEL
__________ M __________
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
ABB DESCRIPTION
MFR MANUFACTURE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
__________ N __________
N NORTH
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
__________ O __________
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
__________ P __________
PART PARTITION
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PNL PANEL
PREFAB PREFABRICATED
PROP PROPERTY
PSI POUNDS PER SQUARE INCH
PTD PAINTED
__________ Q __________
QTY QUANTITY
__________ R __________
R RISER OR RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFRIGERATOR
REG REGISTER
REINF REINFORCING
REQ'D REQUIRED
REQMT REQUIREMENTS
RG RANGE
RM ROOM
RO ROUGH OPENING
RTS RUBBER TRANSITION STRIP
RWC RAIN WATER CONDUCTOR
__________ S __________
S SOUTH
SAN SANITARY
SCHD SCHEDULE
SEC SECTION
SF SQUARE FOOT
SIM SIMILAR
SPEC SPECIFY, SPECIFIED OR SPECIFICATIONS
SPKLR SPRINKLER
SQ SQUARE
SQ FT SQUARE FOOT
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STN STAINED
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPEND, SUSPENDED, OR SUSPENSION
SYS SYSTEM
__________ T __________
"T" TEE (BAR OR W)
T/ TOP OF
TEMP TEMPERED OR TEMPERATURE
THRESH THRESHOLD
TLT TOILET
TYP TYPICAL
__________ U __________
UH UNIT HEATER
UL UNDERWRITER'S LABORATORY
UNO UNLESS NOTED OTHERWISE
__________ V __________
VIF VERIFY IN FIELD
__________ W __________
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WP WATERPROOF(ING)
WT WEIGHT
REVISIONS
NO. DATE DESCRIPTION
444
D W
REF.
DW
A-2.1 2
A-2.1 1
A-2.1 4
A-2.1 3
1 A-3.1
2 A-3.1
BEDROOM BEDROOM
LIVING
BEDROOM
CLOSET
CLO.
CLOSET
BATH
BATH
2' - 1"
WALK-IN CLOSET
4' - 6"
12' - 5"
10' - 2" 5' - 8"
14' - 0" 3' - 1"
2' - 6"
5' - 9" 5' - 9" 10' - 5"
14' - 9"
11' - 7" 2' - 1" 27' - 10"
KITCHEN
ALTERNATE
WALK-IN CLOSET
8' - 1" 2' - 10"
1.01 A
AA
AA
A
63 8
4 5
9 9.1
10 A
2 AA
7 AA
A
BB
3 A-3.1
321
CD
15' - 0"
12' - 7"
A
31' - 0"
43' - 0"
15' - 4" 15' - 8"
34' - 0" 9' - 0"
2' - 11"
B
14' - 8 1/2" 19' - 3 1/2" 9' - 0"
SLOPE
DOWN
SLOPEDOWN
SLOPE
DOWN
DOWN
SLOPE
5' - 11" 3' - 0" 5' - 3" 3' - 0" 9' - 0" 3' - 0" 1' - 10" 4' - 1 1/2" 3' - 0" 1' - 1" 3' - 0" 6' - 9" 3' - 0" 1' - 1" 3' - 0" 6' - 9" 2' - 11" 1' - 1" 2' - 11" 4' - 3 1/2" 1' - 10" 3' - 0" 10' - 6"
1.20 1.07
1.07 1.17
1.09 1.14
1.03 1.17
1.03 1.15
1.19 1.17
1.17 1.17
1.10 1.11
1.12 1.13
1.08 1.16
TYP.
LINE ABOVE,
TYP.
1.10 1.11
1.12 1.13
1.03 1.04
2' - 8" 3' - 0" 1' - 1" 3' - 0" 11" 3' - 0" 2' - 0"
12' - 4 1/2" 2' - 8" 3' - 7" 2' - 8" 3' - 10" 3' - 0" 1' - 1" 3' - 0" 1' - 9 1/2" A 1.04
1.05 1.06
A
1 1.17
LINE OF CLG
ABOVE, TYP.
CLOSET
1.21 PATIO
1.25 1.23
1.24 1.23
1.23 1.23
A-5.1
2B
A-5.1
1B
TYP.
A-5.1
1A TYP.
A-2.1 2
A-2.1 1
A-2.1 4
A-2.1 3
1 A-3.1
2 A-3.1
SLOPE
4"/12"
SLOPE
4"/12"
SLOPE 4"/12"
1.02 3
A-3.1
321
CDAB
SETBACK
2' - 0" 1' - 6" 2' - 0"
2' - 0" 3' - 0"
2' - 0"
2' - 0"
1.18 1.18
1.22A
1. 2.
3. 4.
5. 6.
7. REFER TO GENERAL NOTES SHEET A1.0 FOR ADDITIONAL
REQUIREMENTS.
REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING
INFORMATION.
ALL FURNITURE AND EQUIPMENT IS BY OWNER AND IS SHOWN
FOR COORDINATION PURPOSES ONLY.
SEE STRUCTURAL FOR EXTERIOR STUD WALL SIZE.
ONE (MIN.) SIDE-HINGED EGRESS DOOR SHALL BE PROVIDED
WITH A CLEAR WIDTH OF NOT LESS THAN 32” WHERE MEASURED
BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE
DOOR OPEN 90°. THE CLEAR HEIGHT OF THE DOOR OPENING
SHALL BE NOT LESS THAN 78” IN HEIGHT MEASURED FROM THE
TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP.
REFER TO MECHANICAL AND PLUMBING PLAN FOR WATER
EFFICIENCY REQUIREMENTS FOR ALL PLUMBING FIXTURES.
ROOF OVERHANG DIMENSIONS ARE FROM FACE OF EXTERIOR
WALL FRAMING TO EDGE OF ROOF
FLOOR AND ROOF PLAN GENERAL SHEET NOTES
1. 2.
3. SOLAR READY ROOF MINIMUM AREA: 250 SF
THE SOLAR ZONE TOTAL ARE SHALL BE COMPRISED OF AREAS
THAT HAVE NO DIMENSION LESS THAN 5 FT. THE SOLAR ZONE
SHALL BE LOCATED ON THE ROOF OR OVERHANG OF THE
BUILDING. [CEC 2022 SECTION 110.10.(b)]
FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33
PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS
THAN AN 18-INCH CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS
OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL
ROOF AREA, NOT LESS THAN A 36-INCH CLEAR SETBACK IS
REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. [CRC
R329.6.2]
THE SOLAR ZONE SHALL COMPLY WITH ACCESS, PATHWAY,
SMOKE VENTILATION, AND SPACING REQUIREMENTS AS
SPECIFIED IN TILE 24, PART 9 OR OTHER PARTS OF TITLE 24 OR IN ANY REQUIREMENTS ADOPTED BY LOCAL JURISDICTION.
SOLAR READY GENERAL NOTES
SOLAR ZONE
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
NET FREE VENTING AREA REQUIRED = (ENCLOSED AREA / 150)
[CRC R806.2]
ENCLOSED ATTIC SPACE
(229 SF / 150) = 1.52 SF MIN. [220 SQ. IN.]
ENCLOSED RAFTER SPACE
(966 SF / 150) = 6.44 SF MIN. [928 SQ. IN.]
ROOF VENTING CALCULATIONS
WALLS AND PROJECTIONS LESS THAN 5 FEET FROM THE PROPERTY LINE SHALL COMPLY WITH CRC TABLES R302.1(1) AND (2).
VENT TYPE A: 1/2" X 14" (24 SQ. IN. VENTING AREA), EQUALLY SPACED.
VULCAN FIRE STOPPING SOFFIT VENT OR EQUIVALENT.
(5) TYPE A VENTS
(2) TYPE B VENTS
(39) TYPE A VENTS
VENT TYPE B: 1" X 120" (50 SQ. IN. VENTING AREA), CENTERED.
VULCAN CONTINUOUS RIDGE VENT OR EQUIVALENT.
ROOF VENTING KEY PLAN
ATTIC SPACE
ENCLOSED
RAFTER SPACE
N.T.S
LEGEND
INDICATES LOCATION OF REINFORCEMENT FOR AGING-INPLACE DESIGN AND FALL PROVENTION. SEE 9/A-5.1 FOR ADDITIONAL INFORMATION.
A PROVIDE SAFETY GLAZING PER CRC R308.4.2
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - FLOOR PLAN AND ROOF PLAN (CRAFTSMAN)
A-1.1
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
FLOOR PLAN - CRAFTSMAN
1 SCALE: 1/4" = 1'-0"
ROOF PLAN - CRAFTSMAN
2 AREA: 1195 SF
KEYNOTES
1.01 LINE OF ROOF ABOVE
1.02 LINE OF BUILDING
1.03 EMEREGENCY EGRESS WINDOW AT SLEEPING ROOM
1.04 LANDING OR FLOOR REQUIRED AT EACH SIDE OF EXTERIOR
DOOR WITH MINIMUM WIDTH EQUAL TO THE WIDTH OF THE
DOOR SERVED AND MINIMUM DEPTH OF 36”. AND 36” MINIMUM
DEPTH MEASURED IN THE DIRECTION OF TRAVEL. LANDING OR
FINISHED FLOOR SHALL NOT BE MORE THAN 1 ½” LOWER THAN
THE TOP OF THE THRESHOLD. THE LANDING ON THE EXTERIOR
SIDE SHALL BE NOT MORE THAN 7 ¾” BELOW THE TOP OF THE
THRESHOLD PROVIDED THAT THE DOOR DOES NOT SWING OVER
THE LANDING OR FLOOR.
1.05 EXTERIOR LANDING SURFACE SLOPE NOT TO EXCEED ¼”/FOOT
AWAY FROM BUILDING
1.06 DOOR BELL, 48” MAX ABOVE EXTERIOR LANDING.
1.07 DOOR MUST PROVIDE NET CLEAR OPENING OF 32”
1.08 36” HIGH COUNTERTOP
1.09 SHELF AND HANGING ROD AT CLOSET
1.10 WALLS AND FLOORS AT BATHTUB AND SHOWER SPACES SHALL BE FINISHED WITH NON-ABSORBENT SURFACES. SUCH WALL
SURFACES SHALL EXTEND TO 72” MIN.
1.11 PROVIDE TEMPERED GLAZED ENCLOSURE AT OR ADJACENT TO
BATHTUBS AND/OR SHOWERS WHERE THE BOTTOM EXPOSED
EDGE OF GLAZING IS LESS THAN 60” ABOVE ANY STANDING OR
WALKING SURFACE.
1.12 PROVIDE REINFORCEMENT FOR GRAB BARS [CRC R327.1]. SEE
FLOOR PLAN GENERAL NOTES FOR ADDITIONAL INFORMATION
AND REQUIREMENTS.
1.13 PROVIDE FURRING AS NEEDED FOR STANDARD BATHTUB AND SHOWER LENGTH.
1.14 DRYER VENT AT EXTERIOR WALL MIN. 3 FT FROM ANY OPENING
1.15 2X6 STUD WALL
1.16 STACKED WASHER/DRYER MACHINE LOCATION
1.17 CEILING AT 8'-0" A.F.F.
1.18 GUTTER AND DOWNSPOUTS. PROVIDE DOWNSPOUT LOCATIONS AS REQUIRED BY SITE SPECIFIC CONDITIONS.
1.19 WATER HEATER, REFER TO MEP.
1.20 ATTIC ACCESS, ABOVE. MINIMUM 22” X 30” CLEAR OPENING.
ATTIC ACCESS DOORS SHALL HAVE PERMANENTLY ATTACHED
INSULATION USING ADHESIVE OR MECHANICAL FASTENERS. THE
ATTIC ACCESS SHALL BE GASKETED TO PREVENT AIR LEAKAGE
[CENC 150.0(A)2]
1.21 A CONDENSING UNIT SUPPORTED FROM THE GROUND SHALL
REST ON A CONCRETE OR OTHER APPROVED BASE EXTENDING
NOT LESS THAN 3 INCHES ABOVE THE ADJOINING GROUND
LEVEL [CMC 1105.2]
1.22A ASPHALT SHINGLE ROOF
1.23 INDOOR UNIT, REFER TO MEP.
1.24 ELECTRICAL SUBPANEL, REFER TO MEP.
1.25 BATHROOM SHALL COMPLY WITH AGING-IN-PLACE
REQUIREMENTS
REVISIONS
NO. DATE DESCRIPTION
445
D W
REF.
DW
1 A-3.2
2 A-3.2
A-2.2 2
A-2.2 3
A-2.2 4
A-2.2 1
BEDROOM BEDROOM
BEDROOM
CLOSET
CLO.
BATH
WALK-IN CLOSET
4' - 5"
KITCHEN
ALTERNATE
WALK-IN CLOSET
8' - 1"
CLOSET
1.01 A
AA
AA
A
3 6
8 4
5 9
9.1 10
A
A
2 A
7 AA
A
BB
3 A-3.2
321
CD
2' - 1"
WALK-IN CLOSET
4' - 6"
12' - 5"
10' - 2" 5' - 8"
14' - 0" 3' - 1"
2' - 6"
5' - 9" 5' - 9" 10' - 5"
14' - 9"
11' - 7" 2' - 1" 27' - 10"
2' - 10"
A
31' - 0"
43' - 0"
15' - 4" 15' - 8"
34' - 0" 9' - 0"
12' - 7"
15' - 0"
B
14' - 8 1/2" 19' - 3 1/2" 9' - 0"
2' - 11"
SLOPE
DOWN
SLOPEDOWN
DOWN
SLOPE
5' - 11" 3' - 0" 5' - 3" 3' - 0" 9' - 0" 3' - 0" 1' - 10" 4' - 1 1/2" 3' - 0" 1' - 1" 3' - 0" 6' - 9" 3' - 0" 1' - 1" 3' - 0" 6' - 9" 2' - 11" 1' - 1" 2' - 11" 4' - 3 1/2" 12' - 4 1/2" 2' - 8" 3' - 7" 2' - 8" 3' - 10" 3' - 0" 1' - 1" 3' - 0" 1' - 9 1/2" 1' - 10" 3' - 0" 10' - 6"
1.20 1.04
1.07 1.07
1.17 1.09
1.14 1.03
1.17 1.03
1.15 1.19
1.17 1.17
1.10 1.11
1.12 1.13
1.08 1.16
TYP.
LINE ABOVE,
TYP.
1.10 1.11
1.12 1.13
1.03 2
2' - 8" 3' - 0" 1' - 1" 3' - 0" 11" 3' - 0" 2' - 0" A A 1
1.17 LINE OF CLG
ABOVE, TYP.
3' - 10"
SLOPE
DOWN
CLOSET
1.21 1.04
1.05 1.06
PATIO
BATH
1.17 1.25
LIVING
1.23 1.24
1.23 1.23
1.23 A-5.1
3B
TYP.
A-5.1
3A
TYP.
1 A-3.2
2 A-3.2
A-2.2 2
A-2.2 3
A-2.2 4
A-2.2 1
SLOPE
4"/12"
SLOPE
4"/12"
SLOPE
4"/12"
SLOPE 4"/12"
1.02 3
A-3.2
321
CDAB
SETBACK
1' - 6"
SLOPE
DOWN
1.18 1.18
1' - 3" 13' - 2" AWNING 1' - 3"
AWNING
3' - 10"
8"
8"
8"
8" 8"
8"
1.22B
1. 2.
3. 4.
5. 6.
7. REFER TO GENERAL NOTES SHEET A1.0 FOR ADDITIONAL
REQUIREMENTS.
REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING
INFORMATION.
ALL FURNITURE AND EQUIPMENT IS BY OWNER AND IS SHOWN
FOR COORDINATION PURPOSES ONLY.
SEE STRUCTURAL FOR EXTERIOR STUD WALL SIZE.
ONE (MIN.) SIDE-HINGED EGRESS DOOR SHALL BE PROVIDED
WITH A CLEAR WIDTH OF NOT LESS THAN 32” WHERE MEASURED
BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE
DOOR OPEN 90°. THE CLEAR HEIGHT OF THE DOOR OPENING
SHALL BE NOT LESS THAN 78” IN HEIGHT MEASURED FROM THE
TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP.
REFER TO MECHANICAL AND PLUMBING PLAN FOR WATER
EFFICIENCY REQUIREMENTS FOR ALL PLUMBING FIXTURES.
ROOF OVERHANG DIMENSIONS ARE FROM FACE OF EXTERIOR
WALL FRAMING TO EDGE OF ROOF
FLOOR AND ROOF PLAN GENERAL SHEET NOTES
1. 2.
3. SOLAR READY ROOF MINIMUM AREA: 250 SF
THE SOLAR ZONE TOTAL ARE SHALL BE COMPRISED OF AREAS
THAT HAVE NO DIMENSION LESS THAN 5 FT. THE SOLAR ZONE
SHALL BE LOCATED ON THE ROOF OR OVERHANG OF THE
BUILDING. [CEC 2022 SECTION 110.10.(b)]
FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33
PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS
THAN AN 18-INCH CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS
OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL
ROOF AREA, NOT LESS THAN A 36-INCH CLEAR SETBACK IS
REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. [CRC
R329.6.2]
THE SOLAR ZONE SHALL COMPLY WITH ACCESS, PATHWAY,
SMOKE VENTILATION, AND SPACING REQUIREMENTS AS
SPECIFIED IN TILE 24, PART 9 OR OTHER PARTS OF TITLE 24 OR IN ANY REQUIREMENTS ADOPTED BY LOCAL JURISDICTION.
SOLAR READY GENERAL NOTES
SOLAR ZONE
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
NET FREE VENTING AREA REQUIRED = (ENCLOSED AREA / 150)
[CRC R806.2]
ENCLOSED ATTIC SPACE
(229 SF / 150) = 1.52 SF MIN. [220 SQ. IN.]
ENCLOSED RAFTER SPACE
(966 SF / 150) = 6.44 SF MIN. [928 SQ. IN.]
ROOF VENTING CALCULATIONS
WALLS AND PROJECTIONS LESS THAN 5 FEET FROM THE PROPERTY LINE SHALL COMPLY WITH CRC TABLES R302.1(1) AND (2).
VENT TYPE A: 1/2" X 14" (24 SQ. IN. VENTING AREA), EQUALLY SPACED.
VULCAN FIRE STOPPING SOFFIT VENT OR EQUIVALENT.
(5) TYPE A VENTS
(2) TYPE B VENTS
(39) TYPE A VENTS
VENT TYPE B: 1" X 120" (50 SQ. IN. VENTING AREA), CENTERED.
VULCAN CONTINUOUS RIDGE VENT OR EQUIVALENT.
ROOF VENTING KEY PLAN
ATTIC SPACE
ENCLOSED
RAFTER SPACE
N.T.S
LEGEND
INDICATES LOCATION OF REINFORCEMENT FOR AGING-INPLACE DESIGN AND FALL PROVENTION. SEE 9/A-5.1 FOR ADDITIONAL INFORMATION.
A PROVIDE SAFETY GLAZING PER CRC R308.4.2
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - FLOOR PLAN AND ROOF PLAN (MONTEREY)
A-1.2
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
FLOOR PLAN - MONTEREY
1 SCALE: 1/4" = 1'-0"
ROOF PLAN - MONTEREY
2 AREA: 1195 SF
KEYNOTES
1.01 LINE OF ROOF ABOVE
1.02 LINE OF BUILDING
1.03 EMEREGENCY EGRESS WINDOW AT SLEEPING ROOM
1.04 LANDING OR FLOOR REQUIRED AT EACH SIDE OF EXTERIOR
DOOR WITH MINIMUM WIDTH EQUAL TO THE WIDTH OF THE
DOOR SERVED AND MINIMUM DEPTH OF 36”. AND 36” MINIMUM
DEPTH MEASURED IN THE DIRECTION OF TRAVEL. LANDING OR
FINISHED FLOOR SHALL NOT BE MORE THAN 1 ½” LOWER THAN
THE TOP OF THE THRESHOLD. THE LANDING ON THE EXTERIOR
SIDE SHALL BE NOT MORE THAN 7 ¾” BELOW THE TOP OF THE
THRESHOLD PROVIDED THAT THE DOOR DOES NOT SWING OVER
THE LANDING OR FLOOR.
1.05 EXTERIOR LANDING SURFACE SLOPE NOT TO EXCEED ¼”/FOOT
AWAY FROM BUILDING
1.06 DOOR BELL, 48” MAX ABOVE EXTERIOR LANDING.
1.07 DOOR MUST PROVIDE NET CLEAR OPENING OF 32”
1.08 36” HIGH COUNTERTOP
1.09 SHELF AND HANGING ROD AT CLOSET
1.10 WALLS AND FLOORS AT BATHTUB AND SHOWER SPACES SHALL BE FINISHED WITH NON-ABSORBENT SURFACES. SUCH WALL
SURFACES SHALL EXTEND TO 72” MIN.
1.11 PROVIDE TEMPERED GLAZED ENCLOSURE AT OR ADJACENT TO
BATHTUBS AND/OR SHOWERS WHERE THE BOTTOM EXPOSED
EDGE OF GLAZING IS LESS THAN 60” ABOVE ANY STANDING OR
WALKING SURFACE.
1.12 PROVIDE REINFORCEMENT FOR GRAB BARS [CRC R327.1]. SEE
FLOOR PLAN GENERAL NOTES FOR ADDITIONAL INFORMATION
AND REQUIREMENTS.
1.13 PROVIDE FURRING AS NEEDED FOR STANDARD BATHTUB AND SHOWER LENGTH.
1.14 DRYER VENT AT EXTERIOR WALL MIN. 3 FT FROM ANY OPENING
1.15 2X6 STUD WALL
1.16 STACKED WASHER/DRYER MACHINE LOCATION
1.17 CEILING AT 8'-0" A.F.F.
1.18 GUTTER AND DOWNSPOUTS. PROVIDE DOWNSPOUT LOCATIONS AS REQUIRED BY SITE SPECIFIC CONDITIONS.
1.19 WATER HEATER, REFER TO MEP.
1.20 ATTIC ACCESS, ABOVE. MINIMUM 22” X 30” CLEAR OPENING.
ATTIC ACCESS DOORS SHALL HAVE PERMANENTLY ATTACHED
INSULATION USING ADHESIVE OR MECHANICAL FASTENERS. THE
ATTIC ACCESS SHALL BE GASKETED TO PREVENT AIR LEAKAGE
[CENC 150.0(A)2]
1.21 A CONDENSING UNIT SUPPORTED FROM THE GROUND SHALL
REST ON A CONCRETE OR OTHER APPROVED BASE EXTENDING
NOT LESS THAN 3 INCHES ABOVE THE ADJOINING GROUND
LEVEL [CMC 1105.2]
1.22B TILE ROOF
1.23 INDOOR UNIT, REFER TO MEP.
1.24 ELECTRICAL SUBPANEL, REFER TO MEP.
1.25 BATHROOM SHALL COMPLY WITH AGING-IN-PLACE
REQUIREMENTS
REVISIONS
NO. DATE DESCRIPTION
446
D W
REF.
DW
A-2.3 2
A-2.3 3
A-2.3 4
A-2.3 1
1 A-3.3
2 A-3.3
BEDROOM BEDROOM
BEDROOM
CLOSET
CLO.
CLOSET
BATH
KITCHEN
ALTERNATE
WALK-IN CLOSET
CLOSET
1.01 A
AA
A
AA
A
3 6
8 4
5 9
9.1 10
A
2 AA
7 AA
A
BB
3 A-3.3
321
CD
2' - 1"
WALK-IN CLOSET
4' - 6"
12' - 5"
10' - 2" 5' - 8"
14' - 0" 3' - 1"
2' - 6"
5' - 9" 5' - 9" 10' - 5"
14' - 9"
11' - 7" 2' - 1" 27' - 10"
8' - 1" 2' - 10"
15' - 0"
12' - 7"
A
31' - 0"
43' - 0"
15' - 4" 15' - 8"
34' - 0" 9' - 0"
B
14' - 8 1/2" 19' - 3 1/2" 9' - 0"
2' - 11"
SLOPE
DOWN
SLOPEDOWN
DOWN
SLOPE
12' - 4 1/2" 2' - 8" 3' - 7" 2' - 8" 3' - 10" 3' - 0" 1' - 1" 3' - 0" 1' - 9 1/2" 5' - 11" 3' - 0" 5' - 3" 3' - 0" 9' - 0" 3' - 0" 1' - 10" 4' - 1 1/2" 3' - 0" 1' - 1" 3' - 0" 6' - 9" 3' - 0" 1' - 1" 3' - 0" 6' - 9" 2' - 11" 1' - 1" 2' - 11" 4' - 3 1/2" 1' - 10" 3' - 0" 10' - 6"
1.20 1.07
1.07 1.17
1.09 1.14
1.03 1.17
1.03 1.15
1.19 1.17
1.17 1.10
1.11 1.12
1.13 1.08
1.16 TYP.
LINE ABOVE,
TYP.
1.10 1.11
1.12 1.13
1.03 1.04
2' - 8" 3' - 0" 1' - 1" 3' - 0" 11" 3' - 0" 2' - 0" A 1
1.17 LINE OF CLG
ABOVE, TYP.
SLOPE
DOWN
1.21 1.04
1.05 1.06
PATIO
BATH
1.17 1.25
LIVING
1.23 1.24
1.23 1.23
1.23 A-5.1
1B
TYP.
A-5.1
1A
TYP.
A-2.3 2
A-2.3 3
A-2.3 4
A-2.3 1
1 A-3.3
2 A-3.3
SLOPE
4"/12"
SLOPE
4"/12"
SLOPE 4"/12"
1.02 3
A-3.3
321
CDAB
SETBACK
2' - 0" 1' - 6" 2' - 0"
2' - 0" 3' - 0"
2' - 0"
2' - 0"
1.22C
1. 2.
3. 4.
5. 6.
7. REFER TO GENERAL NOTES SHEET A1.0 FOR ADDITIONAL
REQUIREMENTS.
REFER TO STRUCTURAL DRAWINGS FOR ROOF FRAMING
INFORMATION.
ALL FURNITURE AND EQUIPMENT IS BY OWNER AND IS SHOWN
FOR COORDINATION PURPOSES ONLY.
SEE STRUCTURAL FOR EXTERIOR STUD WALL SIZE.
ONE (MIN.) SIDE-HINGED EGRESS DOOR SHALL BE PROVIDED
WITH A CLEAR WIDTH OF NOT LESS THAN 32” WHERE MEASURED
BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE
DOOR OPEN 90°. THE CLEAR HEIGHT OF THE DOOR OPENING
SHALL BE NOT LESS THAN 78” IN HEIGHT MEASURED FROM THE
TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP.
REFER TO MECHANICAL AND PLUMBING PLAN FOR WATER
EFFICIENCY REQUIREMENTS FOR ALL PLUMBING FIXTURES.
ROOF OVERHANG DIMENSIONS ARE FROM FACE OF EXTERIOR
WALL FRAMING TO EDGE OF ROOF
FLOOR AND ROOF PLAN GENERAL SHEET NOTES
1. 2.
3. SOLAR READY ROOF MINIMUM AREA: 250 SF
THE SOLAR ZONE TOTAL ARE SHALL BE COMPRISED OF AREAS
THAT HAVE NO DIMENSION LESS THAN 5 FT. THE SOLAR ZONE
SHALL BE LOCATED ON THE ROOF OR OVERHANG OF THE
BUILDING. [CEC 2022 SECTION 110.10.(b)]
FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33
PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS
THAN AN 18-INCH CLEAR SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS
OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL
ROOF AREA, NOT LESS THAN A 36-INCH CLEAR SETBACK IS
REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. [CRC
R329.6.2]
THE SOLAR ZONE SHALL COMPLY WITH ACCESS, PATHWAY,
SMOKE VENTILATION, AND SPACING REQUIREMENTS AS
SPECIFIED IN TILE 24, PART 9 OR OTHER PARTS OF TITLE 24 OR IN ANY REQUIREMENTS ADOPTED BY LOCAL JURISDICTION.
SOLAR READY GENERAL NOTES
SOLAR ZONE
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
NET FREE VENTING AREA REQUIRED = (ENCLOSED AREA / 150)
[CRC R806.2]
ENCLOSED ATTIC SPACE
(229 SF / 150) = 1.52 SF MIN. [220 SQ. IN.]
ENCLOSED RAFTER SPACE
(966 SF / 150) = 6.44 SF MIN. [928 SQ. IN.]
ROOF VENTING CALCULATIONS
WALLS AND PROJECTIONS LESS THAN 5 FEET FROM THE PROPERTY LINE SHALL COMPLY WITH CRC TABLES R302.1(1) AND (2).
VENT TYPE A: 1/2" X 14" (24 SQ. IN. VENTING AREA), EQUALLY SPACED.
VULCAN FIRE STOPPING SOFFIT VENT OR EQUIVALENT.
(5) TYPE A VENTS
(2) TYPE B VENTS
(39) TYPE A VENTS
VENT TYPE B: 1" X 120" (50 SQ. IN. VENTING AREA), CENTERED.
VULCAN CONTINUOUS RIDGE VENT OR EQUIVALENT.
ROOF VENTING KEY PLAN
ATTIC SPACE
ENCLOSED
RAFTER SPACE
N.T.S
LEGEND
INDICATES LOCATION OF REINFORCEMENT FOR AGING-INPLACE DESIGN AND FALL PROVENTION. SEE 9/A-5.1 FOR ADDITIONAL INFORMATION.
A PROVIDE SAFETY GLAZING PER CRC R308.4.2
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - FLOOR PLAN AND ROOF PLAN (MODERN FARMHOUSE) A-1.3
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
FLOOR PLAN - MODERN FARMHOUSE
1 SCALE: 1/4" = 1'-0"
ROOF PLAN - MODERN FARMHOUSE
2 AREA: 1195 SF
KEYNOTES
1.01 LINE OF ROOF ABOVE
1.02 LINE OF BUILDING
1.03 EMEREGENCY EGRESS WINDOW AT SLEEPING ROOM
1.04 LANDING OR FLOOR REQUIRED AT EACH SIDE OF EXTERIOR
DOOR WITH MINIMUM WIDTH EQUAL TO THE WIDTH OF THE
DOOR SERVED AND MINIMUM DEPTH OF 36”. AND 36” MINIMUM
DEPTH MEASURED IN THE DIRECTION OF TRAVEL. LANDING OR
FINISHED FLOOR SHALL NOT BE MORE THAN 1 ½” LOWER THAN
THE TOP OF THE THRESHOLD. THE LANDING ON THE EXTERIOR
SIDE SHALL BE NOT MORE THAN 7 ¾” BELOW THE TOP OF THE
THRESHOLD PROVIDED THAT THE DOOR DOES NOT SWING OVER
THE LANDING OR FLOOR.
1.05 EXTERIOR LANDING SURFACE SLOPE NOT TO EXCEED ¼”/FOOT
AWAY FROM BUILDING
1.06 DOOR BELL, 48” MAX ABOVE EXTERIOR LANDING.
1.07 DOOR MUST PROVIDE NET CLEAR OPENING OF 32”
1.08 36” HIGH COUNTERTOP
1.09 SHELF AND HANGING ROD AT CLOSET
1.10 WALLS AND FLOORS AT BATHTUB AND SHOWER SPACES SHALL BE FINISHED WITH NON-ABSORBENT SURFACES. SUCH WALL
SURFACES SHALL EXTEND TO 72” MIN.
1.11 PROVIDE TEMPERED GLAZED ENCLOSURE AT OR ADJACENT TO
BATHTUBS AND/OR SHOWERS WHERE THE BOTTOM EXPOSED
EDGE OF GLAZING IS LESS THAN 60” ABOVE ANY STANDING OR
WALKING SURFACE.
1.12 PROVIDE REINFORCEMENT FOR GRAB BARS [CRC R327.1]. SEE
FLOOR PLAN GENERAL NOTES FOR ADDITIONAL INFORMATION
AND REQUIREMENTS.
1.13 PROVIDE FURRING AS NEEDED FOR STANDARD BATHTUB AND SHOWER LENGTH.
1.14 DRYER VENT AT EXTERIOR WALL MIN. 3 FT FROM ANY OPENING
1.15 2X6 STUD WALL
1.16 STACKED WASHER/DRYER MACHINE LOCATION
1.17 CEILING AT 8'-0" A.F.F.
1.19 WATER HEATER, REFER TO MEP.
1.20 ATTIC ACCESS, ABOVE. MINIMUM 22” X 30” CLEAR OPENING.
ATTIC ACCESS DOORS SHALL HAVE PERMANENTLY ATTACHED
INSULATION USING ADHESIVE OR MECHANICAL FASTENERS. THE
ATTIC ACCESS SHALL BE GASKETED TO PREVENT AIR LEAKAGE
[CENC 150.0(A)2]
1.21 A CONDENSING UNIT SUPPORTED FROM THE GROUND SHALL
REST ON A CONCRETE OR OTHER APPROVED BASE EXTENDING
NOT LESS THAN 3 INCHES ABOVE THE ADJOINING GROUND
LEVEL [CMC 1105.2]
1.22C STANDING SEAM METAL ROOF
1.23 INDOOR UNIT, REFER TO MEP.
1.24 ELECTRICAL SUBPANEL, REFER TO MEP.
1.25 BATHROOM SHALL COMPLY WITH AGING-IN-PLACE
REQUIREMENTS
REVISIONS
NO. DATE DESCRIPTION
447
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.1
2.05 2.09
2.08 2.02
2.03 2.02
2.03 3 2 1
T.O. SHEATING
± 14' - 0"
A
1 A
4"
1'-0"
4"
1'-0"
4"
1'-0"
A
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.1
2.05 2.02
2.03 3
A-3.1
D C B A
T.O. SHEATING
± 14' - 0"
A A A A A A
2.08 3' - 2"
TYP.
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.1
2.05 2.08
2.02 2.03
1 2 3
T.O. SHEATING
± 14' - 0"
A A A
4"
1'-0"
4"
1'-0"
EA. SIDE 2.08
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.1
2.05 2.02
2.03 2.02
2.03 3
A-3.1
A B C D
T.O. SHEATING
± 14' - 0"
B B
A A
1. 2.
3. 4.
5. 6.
7. 8.
REFER TO GENERAL NOTES SHEET A1.1 FOR ADDITIONAL
REQUIREMENTS
REFERENCE DETAILS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
REFERENCE DOOR AND WINDOW SCHEDULES FOR HEIGHT AND
SILL INFORMATION.
REFERENCE FLOOR PLANS AND FRAMING PLANS FOR
LOCATIONS OF DOORS AND WINDOWS.
CONTRACTOR TO VERIFY COLOR OF FINISH MATERIALS PRIOR
TO COMMENCING WORK.
REFER TO ROOF PLAN FOR ROOF OVERHANG DIMENSIONS.
PROVIDE ALUMINUM GUTTERS.
BUILDINGS SHALL HAVE APPROVED ADDRESS IDENTIFICATION
THAT IS LEGIBLE AND PLACED IN A POSITION THAT IS VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH
THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC
NUMBERS OR ALPHABETICAL LETTERS. LETTERS SHALL NOT BE
SPELLED OUT. EACH CHARACTER SHALL BE NOT LESS THAN 4
INCHES IN HEIGHT WITH A STROKE WIDTH OF NOT LESS THAN ½ INCH. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND
THE BUILDING ADDRESS CANNOT BE VIEWED FROM THE PUBLIC
WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE
USED TO IDENTIFY THE STRUCTURE. ADDRESS IDENTIFICATION
SHALL BE MAINTAINED. [CRC R391.1]
ELEVATION GENERAL SHEET NOTES
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
Sheet #
D
C
B
A
1 2 3 4 5
1 2 3 4 5
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - EXTERIOR ELEVATIONS (CRAFTSMAN)
A-2.1
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
KEYNOTES
2.02 HORIZONTAL FIBER CEMENT SIDING
2.03 STONE VENEER, MATERIAL SHALL COMPLY WITH CRC R703.8
2.05 ASPHALT SHINGLES
2.08 TRIM
2.09 EXPOSED WOOD FRAMING - PRIMER & 2 COATS EXTERIOR
GRADE PAINT, REQUIRED.
0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
ELEVATION A 1 SCALE: 1/4" = 1'-0"ELEVATION B 2
SCALE: 1/4" = 1'-0"
ELEVATION C 3 SCALE: 1/4" = 1'-0"ELEVATION D 4
REVISIONS
NO. DATE DESCRIPTION
448
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.2
2.06 2.01
2.01 2.08
3 2 1
T.O. SHEATING
± 14' - 0"
A
1 A
4"
1'-0"
4"
1'-0"
4"
1'-0"
A
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.2
2.06 2.01
2.08 3
A-3.2
D C B A
T.O. SHEATING
± 14' - 0"
A A A A A A
4"
1'-0"
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.2
2.06 2.01
2.08 1 2 3
T.O. SHEATING
± 14' - 0"
A A A
4"
1'-0"
4"
1'-0"
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.2
2.06 2.08
2.01 2.01
3 A-3.2
A B C D
T.O. SHEATING
± 14' - 0"
B B
A A
4"
1'-0"
1. 2.
3. 4.
5. 6.
7. 8.
REFER TO GENERAL NOTES SHEET A1.1 FOR ADDITIONAL
REQUIREMENTS
REFERENCE DETAILS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
REFERENCE DOOR AND WINDOW SCHEDULES FOR HEIGHT AND
SILL INFORMATION.
REFERENCE FLOOR PLANS AND FRAMING PLANS FOR
LOCATIONS OF DOORS AND WINDOWS.
CONTRACTOR TO VERIFY COLOR OF FINISH MATERIALS PRIOR
TO COMMENCING WORK.
REFER TO ROOF PLAN FOR ROOF OVERHANG DIMENSIONS.
PROVIDE ALUMINUM GUTTERS.
BUILDINGS SHALL HAVE APPROVED ADDRESS IDENTIFICATION
THAT IS LEGIBLE AND PLACED IN A POSITION THAT IS VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH
THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC
NUMBERS OR ALPHABETICAL LETTERS. LETTERS SHALL NOT BE
SPELLED OUT. EACH CHARACTER SHALL BE NOT LESS THAN 4
INCHES IN HEIGHT WITH A STROKE WIDTH OF NOT LESS THAN ½ INCH. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND
THE BUILDING ADDRESS CANNOT BE VIEWED FROM THE PUBLIC
WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE
USED TO IDENTIFY THE STRUCTURE. ADDRESS IDENTIFICATION
SHALL BE MAINTAINED. [CRC R391.1]
ELEVATION GENERAL SHEET NOTES
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
Sheet #
D
C
B
A
1 2 3 4 5
1 2 3 4 5
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - EXTERIOR ELEVATIONS (MONTEREY)
A-2.2
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
ELEVATION A 1 SCALE: 1/4" = 1'-0"ELEVATION B 2
SCALE: 1/4" = 1'-0"
ELEVATION C 3 SCALE: 1/4" = 1'-0"ELEVATION D 4
KEYNOTES
2.01 STUCCO. PROVIDE 2 LAYERS OF GRADE D PAPER UNDER
STUCCO WHEN OVER WOOD SHEATHING. [CRC R703.7.3]
2.06 TILE ROOF
2.08 TRIM
REVISIONS
NO. DATE DESCRIPTION
449
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.3
2.07 2.04
2.08 2.04
2.09 3 2 1
T.O. SHEATING
± 14' - 0"
A A
ALTERNATE:
SHINGLE ROOF
4"
1'-0"
4"
1'-0"
4"
1'-0"
A
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.3
2.07 2.04
2.08 3
A-3.3
D C B A
T.O. SHEATING
± 14' - 0"
A A A A A A
ALTERNATE:
SHINGLE ROOF
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.3
2.07 2.04
2.08 1 2 3
T.O. SHEATING
± 14' - 0"
A A A
ALTERNATE:
SHINGLE ROOF
4"
1'-0"
4"
1'-0"
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.3
2.07 2.08
2.04 2.04
3 A-3.3
A B C D
T.O. SHEATING
± 14' - 0"
B
A A
B
ALTERNATE:
SHINGLE ROOF 1.
2. 3.
4. 5.
6. 7.
8. REFER TO GENERAL NOTES SHEET A1.1 FOR ADDITIONAL
REQUIREMENTS
REFERENCE DETAILS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
REFERENCE DOOR AND WINDOW SCHEDULES FOR HEIGHT AND
SILL INFORMATION.
REFERENCE FLOOR PLANS AND FRAMING PLANS FOR
LOCATIONS OF DOORS AND WINDOWS.
CONTRACTOR TO VERIFY COLOR OF FINISH MATERIALS PRIOR
TO COMMENCING WORK.
REFER TO ROOF PLAN FOR ROOF OVERHANG DIMENSIONS.
PROVIDE ALUMINUM GUTTERS.
BUILDINGS SHALL HAVE APPROVED ADDRESS IDENTIFICATION
THAT IS LEGIBLE AND PLACED IN A POSITION THAT IS VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY.
ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST WITH
THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC
NUMBERS OR ALPHABETICAL LETTERS. LETTERS SHALL NOT BE
SPELLED OUT. EACH CHARACTER SHALL BE NOT LESS THAN 4
INCHES IN HEIGHT WITH A STROKE WIDTH OF NOT LESS THAN ½ INCH. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND
THE BUILDING ADDRESS CANNOT BE VIEWED FROM THE PUBLIC
WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE
USED TO IDENTIFY THE STRUCTURE. ADDRESS IDENTIFICATION
SHALL BE MAINTAINED. [CRC R391.1]
ELEVATION GENERAL SHEET NOTES
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
Sheet #
D
C
B
A
1 2 3 4 5
1 2 3 4 5
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - EXTERIOR ELEVATIONS (MODERN FARMHOUSE)
A-2.3
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
ELEVATION A 1 SCALE: 1/4" = 1'-0"ELEVATION B 2
SCALE: 1/4" = 1'-0"
ELEVATION C 3 SCALE: 1/4" = 1'-0"ELEVATION D 4
KEYNOTES
2.04 BOARD AND BATTEN FIBER CEMENT SIDING
2.07 STANDING SEAM METAL ROOF
2.08 TRIM
2.09 EXPOSED WOOD FRAMING - PRIMER & 2 COATS EXTERIOR
GRADE PAINT, REQUIRED.
REVISIONS
NO. DATE DESCRIPTION
450
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.1
BATH LIVING
321
T.O. SHEATING
± 14' - 0"
ATTIC
3.01 3.03
3.02 3.06
3.07 3.03
3.05 A-5.2
1.1 A-5.1
6B
TYP.
3.09 FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.1
BEDROOM BATH BATH BEDROOM
3 A-3.1
ABCD
T.O. SHEATING
± 14' - 0"
3.01 3.01
3.03 3.06
3.07 3.02 3.04
A-5.2
2.1 A-5.2
2.1 A-5.2
3.1 3.09
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.1
LIVING
321
T.O. SHEATING
± 14' - 0"
3.02 A-5.2
1.1 3.05
3.01 3.07
3.03 3.06
3.09 1.
2. 3.
4. 1.
2. 3.
4. 5.
6. 7.
8. 9.
REFER TO GENERAL NOTES SHEET A-1.0 FOR ADDITIONAL
REQUIREMENTS.
REFERENCE DETAILS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
THE PURPOSE OF THESE DRAWINGS IS TO SHOW
CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC SIZES
AND DETAILS REFER TO ARCHITECTURAL PLANS, ELEVATIONS,
DETAILS, AND STRUCTURAL PLANS.
FIREBLOCKING TO BE LOCATED PER CRC SECTION R302.11:
A. SECTION R302.11 -1.
1. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES
OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES
AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS
FOLLOWS:
1.1 VERTICALLY AT CEILING AND FLOOR LEVELS
1.2 HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.
2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL
AND HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS
AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT
THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER
STAIRS SHALL COMPLY WITH SECTION R302.7.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND
WIRES AT CEILINGS AND FLOOR LEVEL, WITH AN APPROVED
MATERIAL TO RESIST THE FREE PASSAGE OF FLAME PRODUCTS
OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE
SHALL NOT BE REQUIRED TO MEET THE ASTM E136
REQUIREMENTS.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES,
SEE SECTION R1003.19.
B. SECTION R302.11.1 - FIREBLOCKING MATERIALS SHALL
CONSIST OF THE FOLLOWING MATERIALS:
TWO-INCH NOMINAL LUMBER
TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH
BROKEN LAP JOINTS
THE THICKNESS OF 0.719-INCH WOOD STRUCTURAL PANELS
WITH JOINTS BACKED BY 0.719-INCH WOOD STRUCTURAL
PANELS
THE THICKNESS OF 0.75-INCH PARTICLE BOARD WITH
JOINTS BACKED BY 0.75-INCH PARTICLE BOARD
ONE-HALF-INCH GYPSUM BOARD
ONE-FOURTH-INCH CEMENT-BASED MILLBOARD
BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER
OR OTHER APPROVED MATERIAL INSTALLED IN SUCH A
MANNER AS TO BE SECURELY RETAINED IN PLACE
CELLULOSE INSULATION INSTALLED AS TESTED IN
ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE
SPECIFIC APPLICATION.
THE PURPOSE OF THESE DRAWINGS IS TO SHOW
CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC
SIZES AND DETAILS REFER TO ARCHITECTURAL PLANS,
ELEVATIONS, DETAILS, AND STRUCTURAL PLANS.
5. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG
EQUIPMENT AND FIXTURES OCCUR.
6. REFERENCE DOOR AND WINDOW SCHEDULES FOR HEIGHT AND
SILL INFORMATION.
7. REFERENCE FLOOR PLANS AND FRAMING PLANS FOR
LOCATIONS OF DOORS AND WINDOWS.
8. REFER TO TITLE 24 REPORT FOR INSULATION INFORMATION
AND REQUIREMENTS.
9. PROVIDE SOUND INSULATION AT BATHROOMS, LAUNDRY
ROOMS, AND PRIMARY BATHROOMS.
SECTION GENERAL SHEET NOTES
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - BUILDING SECTIONS (CRAFTSMAN)
A-3.1
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
KEYNOTES
3.01 WALL INSULATION, REFER TO TITLE 24 REPORT
3.02 ROOF INSULATION, REFER TO TITLE 24 REPORT. REFER TO DETAILS A, B, AND C ON SHEET A5.2
3.03 WOOD STUD WALL, REFER TO STRUCTURAL DRAWINGS.
3.04 RAFTERS, REFER TO STRUCTURAL DRAWINGS.
3.05 RIDGE BEAM, REFER TO STRUCTURAL DRAWINGS.
3.06 CONCRETE SLAB ON GRADE, REFER TO STRUCTURAL
DRAWINGS
3.07 STRUCTURAL CONCRETE FOOTING, REFER TO STRUCTURAL
DRAWINGS.
3.09 FINISHED GRADE, TYP. FOUNDATION WALLS SHALL EXTEND
ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION
AT ALL POINTS NOT LESS THAN 4 INCHES WHERE MASONRY
VENEER IS USED AND NOT LESS THAN 6 INCHES ELSEWHERE.
[CRC R404.1.6] 0
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
SECTION A
1 SCALE: 1/4" = 1'-0"
SECTION B
2 SCALE: 1/4" = 1'-0"
SECTION C
3 REVISIONS
NO. DATE DESCRIPTION
451
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.2
BATH LIVING
321
T.O. SHEATING
± 14' - 0"
ATTIC
3.02 3.06
3.07 3.03
3.05 A-5.2
1.2 3.01
3.03 A-5.1
5B
TYP.
3.09 FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.2
BEDROOM BATH BATH BEDROOM
3 A-3.2
ABCD
T.O. SHEATING
± 14' - 0"
3.01 3.03
3.06 3.07
3.02 3.04
A-5.2
2.2 A-5.2
2.2 3.01
A-5.2 4
3.09 FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.2
LIVING
321
T.O. SHEATING
± 14' - 0"
A-5.2
1.2 3.02
3.05 3.07
3.01 3.03
3.06 3.09
1. 2.
3. 4.
1. 2.
3. 4.
5. 6.
7. 8.
9. REFER TO GENERAL NOTES SHEET A-1.0 FOR ADDITIONAL
REQUIREMENTS.
REFERENCE DETAILS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
THE PURPOSE OF THESE DRAWINGS IS TO SHOW
CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC SIZES
AND DETAILS REFER TO ARCHITECTURAL PLANS, ELEVATIONS,
DETAILS, AND STRUCTURAL PLANS.
FIREBLOCKING TO BE LOCATED PER CRC SECTION R302.11:
A. SECTION R302.11 -1.
1. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES
OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES
AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS
FOLLOWS:
1.1 VERTICALLY AT CEILING AND FLOOR LEVELS
1.2 HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.
2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL
AND HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS
AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT
THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER
STAIRS SHALL COMPLY WITH SECTION R302.7.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND
WIRES AT CEILINGS AND FLOOR LEVEL, WITH AN APPROVED
MATERIAL TO RESIST THE FREE PASSAGE OF FLAME PRODUCTS
OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE
SHALL NOT BE REQUIRED TO MEET THE ASTM E136
REQUIREMENTS.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES,
SEE SECTION R1003.19.
B. SECTION R302.11.1 - FIREBLOCKING MATERIALS SHALL
CONSIST OF THE FOLLOWING MATERIALS:
TWO-INCH NOMINAL LUMBER
TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH
BROKEN LAP JOINTS
THE THICKNESS OF 0.719-INCH WOOD STRUCTURAL PANELS
WITH JOINTS BACKED BY 0.719-INCH WOOD STRUCTURAL
PANELS
THE THICKNESS OF 0.75-INCH PARTICLE BOARD WITH
JOINTS BACKED BY 0.75-INCH PARTICLE BOARD
ONE-HALF-INCH GYPSUM BOARD
ONE-FOURTH-INCH CEMENT-BASED MILLBOARD
BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER
OR OTHER APPROVED MATERIAL INSTALLED IN SUCH A
MANNER AS TO BE SECURELY RETAINED IN PLACE
CELLULOSE INSULATION INSTALLED AS TESTED IN
ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE
SPECIFIC APPLICATION.
THE PURPOSE OF THESE DRAWINGS IS TO SHOW
CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC
SIZES AND DETAILS REFER TO ARCHITECTURAL PLANS,
ELEVATIONS, DETAILS, AND STRUCTURAL PLANS.
5. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG
EQUIPMENT AND FIXTURES OCCUR.
6. REFERENCE DOOR AND WINDOW SCHEDULES FOR HEIGHT AND
SILL INFORMATION.
7. REFERENCE FLOOR PLANS AND FRAMING PLANS FOR
LOCATIONS OF DOORS AND WINDOWS.
8. REFER TO TITLE 24 REPORT FOR INSULATION INFORMATION
AND REQUIREMENTS.
9. PROVIDE SOUND INSULATION AT BATHROOMS, LAUNDRY
ROOMS, AND PRIMARY BATHROOMS.
SECTION GENERAL SHEET NOTES
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - BUILDING SECTIONS (MONTEREY)
A-3.2
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
KEYNOTES
3.01 WALL INSULATION, REFER TO TITLE 24 REPORT
3.02 ROOF INSULATION, REFER TO TITLE 24 REPORT. REFER TO DETAILS A, B, AND C ON SHEET A5.2
3.03 WOOD STUD WALL, REFER TO STRUCTURAL DRAWINGS.
3.04 RAFTERS, REFER TO STRUCTURAL DRAWINGS.
3.05 RIDGE BEAM, REFER TO STRUCTURAL DRAWINGS.
3.06 CONCRETE SLAB ON GRADE, REFER TO STRUCTURAL
DRAWINGS
3.07 STRUCTURAL CONCRETE FOOTING, REFER TO STRUCTURAL
DRAWINGS.
3.09 FINISHED GRADE, TYP. FOUNDATION WALLS SHALL EXTEND
ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION
AT ALL POINTS NOT LESS THAN 4 INCHES WHERE MASONRY
VENEER IS USED AND NOT LESS THAN 6 INCHES ELSEWHERE.
[CRC R404.1.6] 0
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
SECTION A
1 SCALE: 1/4" = 1'-0"
SECTION B
2 SCALE: 1/4" = 1'-0"
SECTION C
3 REVISIONS
NO. DATE DESCRIPTION
452
FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.3
BATH LIVING
321
T.O. SHEATING
± 14' - 0"
ATTIC
3.02 3.06
3.07 3.03
3.05 A-5.2
1.1 3.01
3.03 A-5.1
4B
TYP.
3.09 FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
1 A-3.3
BEDROOM BATH BATH BEDROOM
3 A-3.3
ABCD
T.O. SHEATING
± 14' - 0"
3.01 3.02
3.03 3.06
3.07 3.04
A-5.2
2.1 A-5.2
2.1 3.01
3.09 FINISHED FLOOR
0"
B.O. ROOF
± 8' - 0"
2 A-3.3
LIVING
321
T.O. SHEATING
± 14' - 0"
3.02 3.05
3.01 3.06
3.07 3.03
A-5.2
1.1 3.09
1. 2.
3. 4.
1. 2.
3. 4.
5. 6.
7. 8.
9. REFER TO GENERAL NOTES SHEET A-1.0 FOR ADDITIONAL
REQUIREMENTS.
REFERENCE DETAILS FOR ADDITIONAL INFORMATION AND
REQUIREMENTS.
THE PURPOSE OF THESE DRAWINGS IS TO SHOW
CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC SIZES
AND DETAILS REFER TO ARCHITECTURAL PLANS, ELEVATIONS,
DETAILS, AND STRUCTURAL PLANS.
FIREBLOCKING TO BE LOCATED PER CRC SECTION R302.11:
A. SECTION R302.11 -1.
1. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES
OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES
AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS
FOLLOWS:
1.1 VERTICALLY AT CEILING AND FLOOR LEVELS
1.2 HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.
2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL
AND HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS
AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT
THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER
STAIRS SHALL COMPLY WITH SECTION R302.7.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND
WIRES AT CEILINGS AND FLOOR LEVEL, WITH AN APPROVED
MATERIAL TO RESIST THE FREE PASSAGE OF FLAME PRODUCTS
OF COMBUSTION. THE MATERIAL FILLING THIS ANNULAR SPACE
SHALL NOT BE REQUIRED TO MEET THE ASTM E136
REQUIREMENTS.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES,
SEE SECTION R1003.19.
B. SECTION R302.11.1 - FIREBLOCKING MATERIALS SHALL
CONSIST OF THE FOLLOWING MATERIALS:
TWO-INCH NOMINAL LUMBER
TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH
BROKEN LAP JOINTS
THE THICKNESS OF 0.719-INCH WOOD STRUCTURAL PANELS
WITH JOINTS BACKED BY 0.719-INCH WOOD STRUCTURAL
PANELS
THE THICKNESS OF 0.75-INCH PARTICLE BOARD WITH
JOINTS BACKED BY 0.75-INCH PARTICLE BOARD
ONE-HALF-INCH GYPSUM BOARD
ONE-FOURTH-INCH CEMENT-BASED MILLBOARD
BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER
OR OTHER APPROVED MATERIAL INSTALLED IN SUCH A
MANNER AS TO BE SECURELY RETAINED IN PLACE
CELLULOSE INSULATION INSTALLED AS TESTED IN
ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE
SPECIFIC APPLICATION.
THE PURPOSE OF THESE DRAWINGS IS TO SHOW
CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC
SIZES AND DETAILS REFER TO ARCHITECTURAL PLANS,
ELEVATIONS, DETAILS, AND STRUCTURAL PLANS.
5. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG
EQUIPMENT AND FIXTURES OCCUR.
6. REFERENCE DOOR AND WINDOW SCHEDULES FOR HEIGHT AND
SILL INFORMATION.
7. REFERENCE FLOOR PLANS AND FRAMING PLANS FOR
LOCATIONS OF DOORS AND WINDOWS.
8. REFER TO TITLE 24 REPORT FOR INSULATION INFORMATION
AND REQUIREMENTS.
9. PROVIDE SOUND INSULATION AT BATHROOMS, LAUNDRY
ROOMS, AND PRIMARY BATHROOMS.
SECTION GENERAL SHEET NOTES
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
3 BEDROOM B - BUILDING SECTIONS (MODERN FARMHOUSE)
A-3.3
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
KEYNOTES
3.01 WALL INSULATION, REFER TO TITLE 24 REPORT
3.02 ROOF INSULATION, REFER TO TITLE 24 REPORT. REFER TO DETAILS A, B, AND C ON SHEET A5.2
3.03 WOOD STUD WALL, REFER TO STRUCTURAL DRAWINGS.
3.04 RAFTERS, REFER TO STRUCTURAL DRAWINGS.
3.05 RIDGE BEAM, REFER TO STRUCTURAL DRAWINGS.
3.06 CONCRETE SLAB ON GRADE, REFER TO STRUCTURAL
DRAWINGS
3.07 STRUCTURAL CONCRETE FOOTING, REFER TO STRUCTURAL
DRAWINGS.
3.09 FINISHED GRADE, TYP. FOUNDATION WALLS SHALL EXTEND
ABOVE THE FINISHED GRADE ADJACENT TO THE FOUNDATION
AT ALL POINTS NOT LESS THAN 4 INCHES WHERE MASONRY
VENEER IS USED AND NOT LESS THAN 6 INCHES ELSEWHERE.
[CRC R404.1.6] 0
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
SECTION A
1 SCALE: 1/4" = 1'-0"
SECTION B
2 SCALE: 1/4" = 1'-0"
SECTION C
3 REVISIONS
NO. DATE DESCRIPTION
453
INTERIOR
INTERIOR EXTERIOR
SHEATHING
EXTERIOR SHEATHING
INSULATION
SIDING
WOOD FRAMING, SEE
STRUCT.
CORNER TRIM
SIDING AT INSIDE CORNER
SEALANT, EA SIDE
2 LAYERS WEATHER
RESISTIVE BARRIER
STONE VENEER AT OUTSIDE CORNER
EXTERIOR SHEATHING
INSULATION
WOOD FRAMING, SEE
STRUCT.
INTERIOR
SHEATHING
STONE VENEER
2 LAYERS WEATHER
RESISTIVE BARRIER
EXTERIOR INTERIOR
MORTAR SETTING BED
OVER SCRATCH COAT
METAL LATH
EXTERIOR SHEATHING
INSULATION
7/8" THICK STUCCO FINISH:
METAL LATH BELOW
SCRATCH, BROWN AND FINISH
COAT PER CRC R703.7
WOOD FRAMING, SEE
STRUCT.
INTERIOR
SHEATHING
CORNER BEAD
STUCCO AT OUTSIDE CORNER
2 LAYERS WEATHER
RESISTIVE BARRIER
EXTERIOR INTERIOR
NOTE: PROVIDE 2 LAYERS OF GRADE D PAPER UNDER STUCCO WHEN OVER WOOD SHEATHING. [CRC R703.7.3]
INSULATION
INTERIOR
SHEATHING
BASE TRIM
FLASHING
SIDING
FLASHING AND SEALANT
2 LAYERS OF WEATHER
RESISTIVE BARRIER
OVER PLYWOOD
GRADE, MIN 5% SLOPE
WOOD FRAMING,
SEE STRUCT.
8" MIN.
STRUCTURAL CONCRETE
FOUNDATION, SEE
STRUCT.
EXTERIOR SHEATHING
INSULATION
INTERIOR
SHEATHING
FLASHING
2 LAYERS OF WEATHER
RESISTIVE BARRIER
OVER PLYWOOD WOOD FRAMING,
SEE STRUCT.
STRUCTURAL CONCRETE
FOUNDATION, SEE
STRUCT.
EXTERIOR SHEATHING
7/8" THICK STUCCO FINISH:
METAL LATH BELOW
SCRATCH, BROWN AND FINISH
COAT PER CRC R703.7
GRADE, MIN 5% SLOPE
8" MIN.
NOTE: PROVIDE 26 GA (MIN) CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH MINIMUM VERTICAL FLANGE. THE WEEP SCREEN SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING [CRC R703.7.2.1]
INSULATION
INTERIOR
SHEATHING
FLASHING
2 LAYERS OF WEATHER
RESISTIVE BARRIER
WOOD FRAMING, OVER PLYWOOD
SEE STRUCT.
STRUCTURAL CONCRETE
FOUNDATION, SEE
STRUCT.
EXTERIOR SHEATHING
MORTAR SETTING BED
OVER SCRATCH COAT
STONE VENEER
GRADE, MIN 5% SLOPE
MIN.
8"
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
THROUGH PENTRATION @ WALL
GYPSUM BOARD
FILL, VOID OR CAVITY
MATERIALS, RATED TO
MATCH WALL RATING
THROUGH
PENETRANTS
DESIGN NO. U356
BEARING WALL RATING - 1 HR RATING 1 2 3 5 4
1 WOOD STUDS
NOMINAL 2X6 SPACED 16" O.C. WITH (2) 2X4 TOP PLATES (1) 2X4 BOTTOM PLATE. STUDS LATERALLY-BRACED BY WOOD
STRUCTURAL PANEL SHEATHING (ITEM 5) AND
EFFECECTIVELY FIRE STOPPED AT TOP AND BOTTOM OF
WALL.
2 GYPSUM BOARD
ANY 5/8 IN. THICK UL CLASSIFIED GYPSUM BOARD THAT IS
ELIGIBLE FOR USE IN DESIGN NOS. L501, G512 OR U305. NOM 5/8 IN. THICK, 4 FT WIDE, APPLIED VERTICALLY AND NAILED TO STUDS AND BEARING PLATES 7 IN. OC WITH 6D CEMENTCOATED NAILS, 1-7/8 IN. LONG WITH 1/4 IN. DIAM HEAD. 4 BATTS AND BLANKETS
MINERAL FIBER OR GLASS FIBER INSULATION, 3-1/2 IN.
THICK, PRESSURE FIT TO FILL WALL CAVITIES BETWEEN
STUDS AND PLATES. MINERAL FIBER INSULATION TO BE
UNFACED AND TO HAVE A MIN DENSITY OF 3 PCF. GLASS
FIBER INSULATION TO BE FACED WITH ALUMINUM FOIL OR
KRAFT PAPER AND TO HAVE A MIN DENSITY OF 0.9 PCF
(MIN R-13 THERMAL INSULATION RATING)
5 WOOD STRUCTURAL PANEL SHEATHING
MIN 7/16 IN. THICK, 4 FT WIDE WOOD STRUCTURAL PANELS,
MIN GRADE "C-D" OR "SHEATHING". INSTALLED WITH LONG
DIMENSION OF SHEET (STRENGTH AXIS) OR FACE GRAIN OF
PLYWOOD PARALLEL WITH OR PERPENDICULAR TO STUDS.
VERTICAL JOINTS CENTERED ON STUDS. HORIZONTAL JOINTS
BACKED WITH NOM 2 BY 4 IN. WOOD BLOCKING. ATTACHED TO
STUDS ON EXTERIOR SIDE OF WALL WITH 6D CEMENT
COATED BOX NAILS SPACED 6 IN. OC AT PERIMETER OF
PANELS AND 12 IN. OC ALONG INTERIOR STUDS.
6 EXTERIOR FACINGS
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S
INSTALLATION INSTRUCTIONS. ONE OF THE FOLLOWING
EXTERIOR FACINGS IS TO BE APPLIED OVER THE SHEATHING:
D. CEMENTITIOUS STUCCO — PORTLAND CEMENT OR
SYNTHETIC STUCCO SYSTEMS WITH SELF-FURRING METAL
LATH OR ADHESIVE BASE COAT. THICKNESS FROM 3/8 TO 3/4
IN., DEPENDING ON SYSTEM.
H. FIBER-CEMENT SIDING — FIBER-CEMENT EXTERIOR
SIDINGS INCLUDING SMOOTH AND PATTERNED PANEL OR LAP
SIDING.
I. WALL AND PARTITION FACINGS AND ACCESSORIES* —
STONE VENEER IS MORTAR BONDED TO A LATH, SCRATCH
COAT AND WATER RESISTANT BARRIER APPLIED TO
SHEATHING, INSTALLED IN ACCORDANCE WITH THE
MANUFACTURERS INSTALLATION INSTRUCTIONS, AND
MEETING THE REQUIREMENTS OF LOCAL CODE AGENCIES.
NON-BEARING WALL PARTITION INTERSECTION—
(OPTIONAL) TWO NOMINAL 2 BY 4 IN. STUD OR NOMINAL 2 BY
6 IN. STUD NAILED TOGETHER WITH TWO 3IN. LONG 10D
NAILS SPACED A MAX. 16 IN. OC. VERTICALLY AND FASTENED
TO ONE SIDE OF THE MINIMUM 2 BY 4 IN. STUD WITH 3 IN.
LONG 10D NAILS SPACED A MAX 16 IN. OC. VERTICALLY.
INTERSECTION BETWEEN PARTITION WOOD STUDS TO BE
FLUSH WITH THE 2 BY 4 IN. STUDS. THE WALL PARTITION
WOOD STUDS ARE TO BE FRAMED BY WITH A SECOND 2 BY 4
IN. WOOD STUD FASTENED WITH 3 IN. LONG 10D NAILS
SPACED A MAX. 16 IN. OC. VERTICALLY. MAXIMUM ONE NONBEARING WALL PARTITION INTERSECTION PER STUD CAVITY.
NON-BEARING WALL PARTITION STUD DEPTH SHALL BE AT A
MINIMUM EQUAL TO THE DEPTH OF THE BEARING WALL.
3 JOINTS AND FASTENER HEADS
GYPSUM BOARD JOINTS COVERED WITH TAPE AND JOINT
COMPOUND. FASTENER HEADS COVERED WITH JOINT
COMPOUND.
THROUGH PENTRATION @ WALL
FRAMING
6 INSULATION
INTERIOR
SHEATHING
BASE TRIM
FLASHING
SIDING
FLASHING AND SEALANT
2 LAYERS OF WEATHER
RESISTIVE BARRIER
OVER PLYWOOD
CONCRETE WALK SURFACE,
MIN 2% SLOPE
WOOD FRAMING,
SEE STRUCT.
STRUCTURAL CONCRETE
FOUNDATION, SEE
STRUCT.
EXTERIOR SHEATHING
2"
1/2" EXPANSION JOINT
INSULATION
INTERIOR
SHEATHING
FLASHING
2 LAYERS OF WEATHER
RESISTIVE BARRIER
OVER PLYWOOD
CONCRETE WALK SURFACE,
MIN 2% SLOPE
WOOD FRAMING,
SEE STRUCT.
STRUCTURAL CONCRETE
FOUNDATION, SEE
STRUCT.
EXTERIOR SHEATHING
2"
7/8" THICK STUCCO FINISH:
METAL LATH BELOW
SCRATCH, BROWN AND FINISH
COAT PER CRC R703.7
1/2" EXPANSION JOINT
NOTE: PROVIDE 26 GA (MIN) CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH MINIMUM VERTICAL FLANGE. THE WEEP SCREEN SHALL BE OF A TYPE THAT WILL ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING [CRC R703.7.2.1]
INSULATION
INTERIOR
SHEATHING
FLASHING
2 LAYERS OF WEATHER
RESISTIVE BARRIER
OVER PLYWOOD
CONCRETE WALK SURFACE,
MIN 2% SLOPE
WOOD FRAMING,
SEE STRUCT.
STRUCTURAL CONCRETE
FOUNDATION, SEE
STRUCT.
EXTERIOR SHEATHING
2"
MORTAR SETTING BED
OVER SCRATCH COAT
1/2" EXPANSION JOINT
STONE VENEER
39 1/4"
32"
39 1/4"
32"
SHOWER
SIDE WALLS BACK WALL
TOILET
39 1/4"
32"
39 1/4"
32"
36" MIN. 54" MIN.
1. 2.
NOTES:
PROVIDE REINFORCEMENT FOR AGING-IN-PLACE DESIGN
AND FALL PREVENTION AS REQUIRED BY CRC R327.1.1
INFORMATION AND/OR DRAWINGS IDENTIFYING THE
LOCATION OF GRAB BAR REINFORCEMENT SHALL BE
PLACED IN THE OPERATION AND MAINTENANCE MANUAL
IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING
STANDARDS CODE, CHAPTER 4, DIVISION 4.4.
[R327.1.1.1 CRC]
FRONT SIDE
39 1/4"
32"
39 1/4"
6"
BATHTUB
SIDE WALLS BACK WALL
REINFORCEMENT AREA,
TYP.
1. 2.
NOTES:
WATER CLOSETS SHALL HAVE 15 INCHES TO ANY WALL OR
OBSTRUCTION ON EACH SIDE OF ITS CENTERLINE AND 24-
INCH CLEAR SPACE IN FRONT. [ 402.5 CPC]
SHOWER COMPARTMENTS SHALL BE NOT LESS THAN 1,024
SQUARE INCHES AND ALSO BE CAPABLE OF
ENCOMPASSING A 30-INCH DIAMETER CIRCLE. [ 408.6 CPC]
MIN.
15"
MIN.
15"
ø 2' - 6"
24"
EXTERIOR SHEATHING
INSULATION
SIDING
WOOD FRAMING, SEE
STRUCT.
INTERIOR
SHEATHING
CORNER TRIM
SIDING AT OUTSIDE CORNER
2 LAYERS WEATHER
RESISTIVE BARRIER
EXTERIOR INTERIOR
INTERIOR
INTERIOR EXTERIOR
SHEATHING
EXTERIOR SHEATHING
INSULATION
7/8" THICK STUCCO FINISH:
METAL LATH BELOW SCRATCH,
BROWN AND FINISH COAT PER
CRC R703.7
WOOD FRAMING, SEE
STRUCT.
2 LAYERS WEATHER
RESISTIVE BARRIER
STUCCO AT INTSIDE CORNER
NOTE: PROVIDE 2 LAYERS OF GRADE D PAPER UNDER STUCCO WHEN OVER WOOD SHEATHING. [CRC R703.7.3]
INTERIOR
EXTERIOR INTERIOR
SHEATHING
EXTERIOR SHEATHING
INSULATION
STONE VENEER
WOOD FRAMING, SEE
STRUCT.
STONE VENEER AT INSIDE CORNER
2 LAYERS WEATHER
RESISTIVE BARRIER
MORTAR SETTING BED
OVER SCRATCH COAT
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
DETAILS
A-5.1
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
SCALE: 1 1/2" = 1'-0"
PLAN DETAIL - SIDING (INSIDE CORNER) 1A
SCALE: 1 1/2" = 1'-0"
PLAN DETAIL - STONE VENEER (OUTSIDE CORNER)
SCALE: 1 1/2" = 1'-0" 3B PLAN DETAIL - STUCCO (OUTSIDE CORNER) 2B SCALE: 1 1/2" = 1'-0"
BASE DETAILS - SIDING AT GRADE 4B SCALE: 1 1/2" = 1'-0"BASE DETAILS - STUCCO AT GRADE 5B SCALE: 1 1/2" = 1'-0"BASE DETAILS - STONE VENEER AT GRADE 6B
REVISIONS
NO. DATE DESCRIPTION
0 SCALE:
6" 1' - 0" 2' - 0"
1 1/2" = 1' - 0"
SCALE: 1 1/2" = 1'-0"
7 FIRE RESISTIVE 1- HOUR
WOOD FRAMED WALLS
SCALE: 1 1/2" = 1'-0"
BASE DETAILS - SIDING AT PAVED WALK 4A SCALE: 1 1/2" = 1'-0"BASE DETAILS - STUCCO AT PAVED WALK 5A SCALE: 1 1/2" = 1'-0"BASE DETAILS - STONE VENEER AT PAVED WALK 6A SCALE: 1/4" = 1'-0"
9 REINFORCEMENT DETAILS
SCALE: 1/4" = 1'-0"
BATHROOM CLEARANCE DIAGRAMS
8 SCALE: 1 1/2" = 1'-0"
PLAN DETAIL - SIDING (OUTSIDE CORNER) 1B
SCALE: 1 1/2" = 1'-0"
PLAN DETAIL - STUCCO (INSIDE CORNER) 2A SCALE: 1 1/2" = 1'-0"PLAN DETAIL - STONE VENEER (INSIDE CORNER) 3A 454
ROOF SHEATHING
GUTTER WITH GUARD
1"X 12" FASCIA BOARD
TONGUE AND GROOVE SOFFIT
ROOFING FINISH MATERIAL
EXTERIOR WALL FINISH PER
ELEVATION
WEATHER RESISTIVE BARRIER
SHEATHING
CL
26 GA GSM EDGE FLASHING 3"
MIN. LAP OVER UNDERLAYMENT
AND 1" MIN. VERTICAL LAP
OVER EDGEBOARD
PER ROOF PLAN
BLOCKING, TYP.
TRIM (AT CRAFTSMAN STYLE)
GUTTER WITH GUARD
1"x 6" FASCIA BOARD
ROOFING FINISH MATERIAL
CL
PLAN
PER ROOF
26 GA GSM EDGE FLASHING 3"
MIN. LAP OVER UNDERLAYMENT
AND 1" MIN. VERTICAL LAP
OVER EDGEBOARD
BLOCKING, TYP.
EXTERIOR WALL FINISH PER
ELEVATION
WEATHER RESISTIVE BARRIER
SHEATHING
SHEATHING & FRAMING PER
STRUCTURAL
2 X BLOCKING
FASCIA BOARD
ROOFING FINISH
MATERIAL
SOFFIT
PER ROOF PLAN
26 GA GSM EDGE
FLASHING 3" MIN. LAP
OVER UNDERLAYMENT
AND 1" MIN. VERTICAL
LAP OVER EDGEBOARD
EXTERIOR WALL FINISH PER
ELEVATION
WEATHER RESISTIVE
BARRIER
SHEATHING
CL
SHEATHING & FRAMING PER
STRUCTURAL
2 X BLOCKING
1" X 6" FASCIA BOARD
26 GA GSM EDGE
FLASHING 3" MIN. LAP
OVER UNDERLAYMENT
AND 1" MIN. VERTICAL
LAP OVER EDGEBOARD
ROOFING FINISH
MATERIAL
CL
SHEATHING & FRAMING PER
STRUCTURAL
2 X BLOCKING
1"x12" FASCIA BOARD
26 GA GSM EDGE
FLASHING 3" MIN. LAP
OVER UNDERLAYMENT
AND 1" MIN. VERTICAL
LAP OVER EDGEBOARD
ROOFING FINISH MATERIAL
SOFFIT
PER ROOF PLAN
EXTERIOR WALL FINISH PER
ELEVATION
WEATHER RESISTIVE
BARRIER
SHEATHING
CL
SHEATHING & FRAMING PER
STRUCTURAL
2 X BLOCKING
1"x12" FASCIA BOARD
26 GA GSM EDGE
FLASHING 3" MIN. LAP
OVER UNDERLAYMENT
AND 1" MIN. VERTICAL
LAP OVER EDGEBOARD
ROOFING FINISH MATERIAL
SOFFIT
PER ROOF PLAN
EXTERIOR WALL FINISH PER
ELEVATION
WEATHER RESISTIVE
BARRIER
SHEATHING
MAX.
9"
CL
ROOFING FINISH MATERIAL
ROOF SHEATHING AND
FRAMING PER STRUCTURAL
26 GA GSM EDGE FLASHING 3" MIN. LAP
OVER UNDERLAYMENT AND 1" MIN.
VERTICAL LAP OVER EDGEBOARD
FASCIA BOARD
LEDGER BOARD, TYP.
REFER TO STRUCT.
4" MIN.
METAL FLASHING, RETURN UP
WALL BEHIND WEATHER
RESISTIVE BARRIER
EXTERIOR WALL FINISH PER
ELEVATION
SHEATHING
WEATHER RESISTIVE BARRIER
DRIP EDGE
6' -8" MIN
WHEN WALKING SURFACE BELOW
6' -8" MIN
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
ROOF RAFTERS, REF STRUCT.
ROOF SHEATHING
AIR- IMPERMEABLE INSULATION IN
CONTACT WITH SHEATHING WITH
REQ'D R-VALUE
GYPSUM BOARD, REF PLANS
ROOF RAFTERS, REF STRUCT.
ROOF SHEATHING
AIR- IMPERMEABLE INSULATION IN
CONTACT WITH SHEATHING WITH
REQ'D R-VALUE
GYPSUM BOARD, REF PLANS
AIR-PERMEABLE INSULATION
INSTALLED DIRECTLY UNDER THE
STRUCTURAL SHEATHING
ROOF RAFTERS, REF STRUCT.
ROOF SHEATHING
AIR- IMPERMEABLE INSULATION IN
CONTACT WITH SHEATHING WITH
REQ. R-VALUE
GYPSUM BOARD, REF PLANS
Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
ROOF DETAILS
A-5.2
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
SCALE: 1" = 1'-0"
CRAFTSMAN/ MODERN FARMHOUSE EAVE 1.1
SCALE: 1" = 1'-0"
MONTEREY EAVE 1.2
SCALE: 1" = 1'-0"
CRAFTSMAN/ MODERN FARMHOUSE GABLE 2.1
SCALE: 1" = 1'-0"
MONTEREY GABLE 2.2
SCALE: 1" = 1'-0"
CRAFTSMAN GABLE (FRONT) 3.1
SCALE: 1" = 1'-0"
3 - MODERN FARMHOUSE GABLE (FRONT) 3.3
SCALE: 1" = 1'-0"
4 - MONTEREY AWNING
4 REVISIONS
NO. DATE DESCRIPTION
0 SCALE:
6" 1' - 0" 2' - 0"
1" = 1' - 0"
B SCALE: 1" = 1'-0"
INSULATION AT UNVENTED ROOF ASSEMBLY -
IMPERMEABLE INSULATION ONLY
SCALE: 1" = 1'-0"
INSULATION @ UNVENTED ROOF ASSEMBLY - BOTH TYPES
A
SCALE: 1" = 1'-0"
INSULATION @ UNVENTED ROOF ASSEMBLY - OVER/ UNDER
C
455
GENERAL WINDOW NOTES
1. 2.
3. 4.
5. 6.
A.
B.
C.
a.
b.
D.
E.
F.
7. REFER TO GENERAL NOTES SHEET A1.0 FOR ADDITIONAL
REQUIREMENTS.
REFER TO FLOOR PLANS FOR LOCATION OF DOORS AND
DIRECTION OF DOOR SWING.
CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES PRIOR
TO FABRICATION OF ROUGH OPENINGS.
ALL GLAZING, INCLUDING GLAZED DOORS AND GLAZED
OPENINGS WITHIN EXTERIOR DOORS, SHALL BE INSULATING
GLASS UNITS WITH A MINIMUM OF ONE TEMPERED PANE.
TEMPERED GLASS SHALL BE PERMENENTLY IDENTIFIED AND
VISIBLE WHEN THE UNIT IS GLAZED.
EXTERIOR FIRE RATED DOORS SHALL COMPLY WITH ONE OF
THE FOLLOWING PER CBC 2022 708A.3:
THE EXTERIOR SURFACE OR CLADDING SHALL BE OF
NONCUMBUSTIBLE MATERIAL
THE EXTERIOR SURFACE CLADDING SHALL BE OF
IGNITION-RESISTANT MATERIALS
THE EXTERIOR DOOR SHALL BE CONSTRUCTED OF SOLID
CORE WOOD THAT COMPLIES WITH THE FOLLOWING
REQUIREMENTS:
THICK
PANELS SHALL NOT BE LESS THAN 1 ¼” THICK,
EXCEPT FOR THE EXTERIOR PERIMETER OF THE
PANEL THAT SHALL BE PERMITTED TO TAPER TO
A TONGUE NOT LESS THAN 3/8” THICK.
THE EXTERIOR DOOR ASSEMBLY SHALL HAVE A FIRERESISTANCE RATING OF NOT LESS THAN 30 MINUTES WHEN TEST ACCORDING TO NFPA 252.
THE EXTERIOR SURFACE CLADDING SHALL BE TESTED TO
MEET THE PERFORMANCE REQUIREMENTS WHEN TESTED
IN ACCORDANCE WITH ASTM E2707
THE EXTERIOR SURFACE OR CLADDING SHALL BE TESTED
TO MEET THE PERFORMANCE REQUIREMENTS OF SFM
STANDARD 12-7A-1.
GLAZING IN FIXED AND OPERABLE PANELS OF SWINGING,
SLIDING, AND BIFOLD DOORS SHALL BE CONSIDERED TO BE A
HAZARDOUS LOCATION [CRC SECTION R308.4]. PROVIDE
SAFETY GLAZING.
GENERAL DOOR NOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. 14.
A.
B.
C.
D.
REFER TO GENERAL NOTES SHEET A-1.0 FOR ADDITIONAL
REQUIREMENTS.
REFER TO FLOOR PLANS FOR WINDOW LOCATIONS.
REFER TO ELEVATIONS FOR DIRECTION OF OPERATION OF
WINDOWS.
PROVIDE ALL OPERABLE WINDOWS WITH SCREENS.
CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES PRIOR
TO FABRICATION OF ROUGH OPENINGS.
REFER TO ENERGY COMPLIANCE REPORTS FOR U-FACTOR,
SHGC AND ADDITIONAL WINDOW REQUIREMENTS.
WINDOWS MUST HAVE A FRAME AND SASH COMPRISED OF
WELDED CORNERS, METAL REINFORCEMENT IN THE INTERLOCK
AREA.
ALL GLAZING SHALL BE INSULATING GLASS UNITS WITH A
MINIMUM OF ONE TEMPERED PANE.
TEMPERED GLASS SHALL BE PERMENENTLY IDENTIFIED AND
VISIBLE WHEN THE UNIT IS GLAZED.
GLAZING IN WALLS ADJACENT TO BATHTUB AND OR SHOWER,
WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS
THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR
WALKING SURFACE, SHALL BE SAFETY GLAZING. [CRC SECTION
R308.4.5]
EMERGENCY ESCAPE AND RESCUE WINDOWS SHALL HAVE A
CLEAR OPENING WITH THE BOTTOM OF THE CLEAR OPENING
NOT GREATER THAN 44" AFF, MIN. THE NET CLEAR OPENING FOR EMERGENCY ESCAPE SHALL BE 5.7 S.F. (5 S.F. MIN. AT GROUND FLOOR). MINIMUM NET CLEAR OPENING DIMENSIONS: HEIGHT:
24", WIDTH: 20". [CRC SECTION R310.2]
EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN
DIRECTLY INTO A PUBLIC WAY, OR TO A YARD OR COURT HAVING A MINIMUM WIDTH OF 36” THAT OPENS TO A PUBLIC WALL [CRC SECTION 310.1]
ALL GLAZING SHALL MEET TITLE 24 ENERGY REQUIREMENTS.
FIRE RATED EXTERIOR WINDOWS AND EXTERIOR GLAZED DOOR
ASSEMBLIES SHALL COMPLY WITH ONE OF THE FOLLOWING
REQUIRMENTS PER CBC 708A.2.1:
BE CONSTRUCTED OF MULTIPANE GLAZING WITH A MINIMUM
OF ONE TEMPERED PANE MEETING THE REQUIREMENTS OF
SECTION 2406 SAFETY GLAZING
BE CONSTRUCTED OF GLASS BLOCK UNITS
HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 20
MINUTES WHEN TESTED ACCORDING TO NFPA 257
BE TESTED TO MEET THE PERFORMANCE REQUIREMENTS
OF SFM STANDARD 12-7A-2.
15. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300.
BY USING THESE PERMIT READY CONSTRUCTION DOCUMENTS, THE RECIPIENT
ACKNOWLEDGES, ACCEPTS, AND VOLUNTARILY AFFIRMS THE FOLLOWING CONDITIONS:
1. THE USE OF THIS INFORMATION IS RESTRICTED TO THE ORIGINAL PROJECT FOR
WHICH IT WAS PREPARED FOR THE PERMIT READY ACCESSORY DWELLING (ADU) PROGRAM FOR THE CITY OF WILDOMAR ONLY. THIS IS A LIMITED SET OF
STANDARDIZED ADU PLANS AND SPECIFICATIONS APPROVED BY THE CITY OF WILDOMAR BUILDING & SAFETY DEPARTMENT. BUILDING CODES DO CHANGE OVER
TIME AND RECIPIENT SHALL ENSURE FULL COMPLIANCE UNDER ALL CODES THEN IN EFFECT AT THE TIME OF THE SUBJECT PERMIT. THIS DOES NOT ELIMINATE OR
REDUCE THE RECIPIENT'S RESPONSIBILITY TO VERIFY ANY AND ALL INFORMATION RELEVANT TO THE RECIPIENT'S WORK AND RESPONSIBILITY ON THIS PROJECT.
MICHAEL BAKER INTERNATIONAL SHALL NOT BE RESPONSIBLE FOR TRANSLATION ERRORS. DO NOT USE THESE CONSTRUCTION DOCUMENTS IF THE PERMIT HAS EXPIRED OR IS REVOKED AT ALL.
2. THE RECIPIENT RECOGNIZES AND ACKNOWLEDGES THAT THE USE OF THIS
INFORMATION WILL BE AT THEIR SOLE RISK AND WITHOUT LIABILITY OR LEGAL EXPOSURE TO MICHAEL BAKER INTERNATIONAL. NO WARRANTIES OF ANY
NATURE, WHETHER EXPRESS OR IMPLIED, SHALL ATTACH TO THESE DOCUMENTS AND THE INFORMATION CONTAINED THEREIN. ANY USE, REUSE, OR ALTERATION
OF THESE DOCUMENTS BY THE RECIPIENT OR OTHERS WILL BE AT THE RECIPIENT'S RISK AND FULL LEGAL RESPONSIBILITY. FURTHERMORE, THE
RECIPIENT WILL, TO THE FULLEST EXTENT PERMITTED BY THE LAW, DEFEND,
INDEMNIFY AND HOLD MICHAEL BAKER INTERNATIONAL AND ITS ARCHITECTS
HARMLESS FROM ANY AND ALL CLAIMS, SUITS, LIABILITY, DEMANDS,
JUDGEMENTS, OR COSTS ARISING OUT OF OR RESULTING THERE FROM ANY USE
OF THESE CONSTRUCTION DOCUMENTS FOR OR ON ACCOUNT OF ANY INJURY,
DEATH, DAMAGE OR LOSS TO PERSONS OR PROPERTY, DIRECT OF CONSEQUENTIAL DAMAGES IN ANY AMOUNT. THIS INDEMNITY DOES NOT APPLY
TO THE SOLE NEGLIGENCE OR WILLFUL MISCONDUCT OF MICHAEL BAKER INTERNATIONAL OR ITS ARCHITECTS.
3. MICHAEL BAKER INTERNATIONAL REPRESENTED BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION.
4. IF THE RECIPIENT DOES NOT AGREE WITH THE ABOVE CONDITIONS, DO NOT
PROCEED WITH CONSTRUCTION OF AN ADU OR OTHER IMPROVEMENT UNDER THESE PLANS AT ALL.
BCD
A
(CRAFTSMAN)
A
(MONTEREY)
A
(MODERN
FARMHOUSE)
6' - 8"6' - 8"6' - 8"
1 3/4"
SCHDL
REF 1 3/4" 1 3/4"
SCHDL
REF 1 3/4" 1 3/4"
SCHDL
REF 1 3/4"
E
1 3/4"
SCHDL
REF 1 3/4"
6' - 8"
A
(CRAFTSMAN)
A
(MONTEREY)
A
(MODERN
FARMHOUSE)
6' - 8"
5 1/2" 3' - 0" 5 1/2"
6' - 8"6' - 8"
4 1/2" 3' - 0" 4 1/2" 5 1/2" 3' - 0" 5 1/2"
TRIM,
TYP.
TRIM,
TYP.
TRIM,
TYP.
4/A-6.1
5/A-6.1
4/A-6.1
5/A-6.1
4/A-6.1
5/A-6.1
A
(MONTEREY)
A
(MODERN FARMHOUSE)
3' - 6" 5 1/2"
A
(CRAFTSMAN)
3 1/2" 3' - 0" 3 1/2"
3 1/2"
3' - 6" 3 1/2"
5 1/2"
3' - 0"
5 1/2"
5 1/2" 3' - 6" 5 1/2"
B
(MONTEREY)
B
(MODERN FARMHOUSE)
HEAD HEIGHT
6' - 8" TYP.
B
(CRAFTSMAN)
5 1/2" 3' - 0" 5 1/2"
5 1/2" 2' - 8"
5 1/2"
3 1/2" 2' - 8" 3 1/2"
3 1/2" 1' - 6" 3 1/2"
5 1/2" 2' - 8" 5 1/2"
5 1/2" 1' - 6" 5 1/2"
5 1/2"
1' - 6"
5 1/2"
HEAD HEIGHT
6' - 8" TYP.
TRIM, TYP.
TRIM, TYP.
1/A-6.1
6/A-6.1
2/A-6.1
1/A-6.1
3/A-6.1
2/A-6.1
1/A-6.1
3/A-6.1
2/A-6.1
1/A-6.1
3/A-6.1
2/A-6.1
1/A-6.1
3/A-6.1
2/A-6.1
1/A-6.1
3/A-6.1
2/A-6.1
NOTE: EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FINISH FLOOR. [CRC R310.2] SILL 3' - 2" TYP.
EXTERIOR SHEATHING
WALL FRAMING. SEE
STRUCT.
EXTERIOR FINISH
MATERIAL
WATER RESISTIVE
BARRIER, MIN 6" OVER
FLASHING
WINDOW
EXTERIOR TRIM
SEALANT AND
BACKER ROD
EXTERIOR INTERIOR
EXTERIOR SHEATHING
WALL FRAMING, SEE
STRUCT.
EXTERIOR FINISH
MATERIAL
WATER RESISTIVE
BARRIER, MIN 6" OVER
FLASHING
DOOR AND FRAME
EXTERIOR TRIM
SEALANT, ALL
SIDES OF TRIM
EXTERIOR INTERIOR
EXTERIOR
SHEATHING
WALL FRAMING
(SEE STRUCT.)
EXTERIOR FINISH
MATERIAL
WATER RESISTIVE
BARRIER
WINDOW
TRIM, SEALANT
ALL SIDES
SEALANT AND
BACKER ROD
EXTERIOR
INTERIOR
DOOR
EXTERIOR
SHEATHING
WALL FRAMING
(SEE STRUCT.)
EXTERIOR FINISH
MATERIAL
WATER RESISTIVE
BARRIER TRIM, SEALANT
ALL SIDES
SEALANT AND
BACKER ROD
EXTERIOR
SHEATHING
WALL FRAMING
EXTERIOR FINISH
MATERIAL
WATER RESISTIVE
BARRIER
WINDOW
SLOPED TRIM
SEALANT AND
BACKER ROD
SILL FLASHING
EXTERIOR
SHEATHING
WALL FRAMING
EXTERIOR FINISH
MATERIAL
WATER RESISTIVE
BARRIER
WINDOW
CONCRETE OR
STONE SILL
SEALANT AND
BACKER ROD
SILL FLASHING
EXTERIOR INTERIOR
SHEET METAL FLASHING,
SOLDER ALL JOINTS
TYP.
4" LAP
2" MIN.
1/4"
6" MIN.
FLASHING PAPER, MOISTOP
FLASHING OR EQUAL (9" WIDE
MIN.) O/ NAILING FIN @ TOP OF
WINDOWS (HEAD) TYP. TWO
CONTINUOUS BEADS OF
MOISTOP SEALANT OR EQUAL
UNDER FLASHING PAPER (1) O/
NAILING FIN AND (1) AT TOP OF
FLSHING PAPER TYP.
FLASHING PAPER, SELF
SEALING MEMBRANE, (9" WIDE
MIN., 12" WIDE TYP. AT JAMBS)
O/ WOOD FRAMING AND UNDER
NAILING FIN AT SIDE OF
WINDOWS (JAMB) TYP.
WINDOW
NAILING FIN.
31 22
••••••••9" MOIST STOP FLASHING PAPER TYP. OF FLASHING PAPER
THE ACTUAL NUMBER OF FLASHING PIECES REQUIRED IS DETERMINED BY THE RADIUS OF THE OPENING AND THE SIZE OF THE FLASHING. (9" WIDE FLASHING MIN.) APPLY A CONTINUOUS BEAD OF SEALANT COMPLYING WITH AAMA 800 TO THE BACKSIDE (INTERIOR) OF THE WINDOW MOUNTING FLANGES
AT WINDOW HEAD, JAMBS AND SILL ALL CORROSIVE RESISTANT FASTENERS ARE TO BE NAILED THROUGH FIN NO CLOSER THAN 3" O.C. AND NOT MORE THAN 16" O.C.
FASTENERS SHALL BE WITHIN 10" FROM CORNERS.
NO NAILS SHALL BE BENT OVER THE NAILING FIN TO SECURE WINDOW REFER TO AAMA 2400-10 STANDARD PRACTICE FOR INSTALLATION OF WINDOWS WITH
MOUNTING FLANGES IN STUD CONSTRUCTION FOR ADDITIONAL REQUIREMENTS
PROVIDE SOLID BLOCKING AT ALL FLASHING LOCATIONS
NOTES:
# INDICATES SEQUENCE
FOR INSTALLATION
SHEET METAL FLASHING,
SOLDER ALL JOINTS OR
PROVIDE SELF ADHERING
WATERPROOFING
TYP.
4" LAP
1"
6" 6"
6 3/4"
1/2"
WATER RESISTIVE
BARRIER/ LATH PAPER UP
AND UNDER FLASHING
(6" LAP MIN).
* LOUVER SHALL PROVIDE MINIMUM 100 SQUARE INCHES FOR MAKEUP AIR (CMC 504.4.1) Sheet #
DCBA
1 2345
12345
SEAL
40810 COUNTY CENTER DRIVE
SUITE 200
TEMECULA, CA 92591
Project Number:
Date:
Scale:
Consultant
AS NOTED
WINDOW AND DOOR SCHEDULES & DETAILS
A-6.1
© Baker 2026
208026
CITY OF WILDOMAR - ACCESSORY DWELLING UNITS
02/27/2026
FINAL DESIGN - 02/27/2026
DOOR SCHEDULE
DOOR
NUMBER TYPE
SIZE
THICK. DOOR MATERIAL
FRAME
HEIGHT WIDTH MATERIAL U-FACTOR SHGC COMMENTS
1A 6' - 8" 3' - 0" 1 3/4" VINYL/GLASS VINYL 0.300 0.23 EXTERIOR, REF GENERAL DOOR NOTE #7 2B 6' - 8" 3' - 0" 1 3/4" HOLLOW WD WD
3B 6' - 8" 3' - 0" 1 3/4" HOLLOW WD WD
4B 6' - 8" 3' - 0" 1 3/4" HOLLOW WD WD
5B 6' - 8" 3' - 0" 1 3/4" HOLLOW WD WD
6B 6' - 8" 3' - 0" 1 3/4" HOLLOW WD WD
7C 6' - 8" 2' - 6" 1 1/2" HOLLOW WD WD LOUVERED*
8D 6' - 8" 6' - 0" 1 3/4" HOLLOW WD WD
9D 6' - 8" 8' - 0" 1 3/4" HOLLOW WD WD
9.1E 6' - 8" 3' - 0" 1 3/4" HOLLOW WD WD DOOR ALTERNATE FOR WALK-IN CLOSET
SELECTION
10D 6' - 8" 5' - 0" 1 3/4" HOLLOW WD WD
WINDOW SCHEDULE
TYPE HEIGHT WIDTH
HEAD
HEIGHT
FRAME
MATERIAL OPERATION U-FACTOR SHGC COMMENTS
A 3' - 6" 3' - 0" 6' - 8" VINYL CASEMENT 0.300 0.23 B 1' - 6" 2' - 8" 6' - 8" VINYL AWNING 0.300 0.23 0 SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1' - 0"
SCALE: 1/4" = 1'-0"
DOOR ELEVATIONS
SCALE: 1/4" = 1'-0"
WINDOW ELEVATIONS
SCALE: 3" = 1'-0"
WINDOW HEAD
1 SCALE: 3" = 1'-0"
DOOR HEAD
4 SCALE: 3" = 1'-0"
WINDOW JAMB
2 SCALE: 3" = 1'-0"
DOOR JAMB
5 SCALE: 3" = 1'-0"
WINDOW SILL
3 SCALE: 3" = 1'-0"
WINDOW SILL - CRAFTSMAN
6 SCALE: 3" = 1'-0"
DOOR THRESHOLD FLASHING
8 SCALE: 3" = 1'-0"
WINDOW FLASHING
9 SCALE: 3" = 1'-0"
WINDOW SILL FLASHING
7 REVISIONS
NO. DATE DESCRIPTION
456
MECHANICAL/PLUMBING NOTES EXHAUST DUCTS AND DRYER VENTS SHALL BE EQUIPPED WITH BACK DRAFT DAMPERS INSULATE ALL HOT WATER PIPES. CAL ENERGY CODE 150.0(j) (2), and CPC 609.11) SMOKE DETECTORS MUST BE PERMANENTLY WIRED. IN NEW CONSTRUCTION, REQUIRED SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. SMOKE ALARMS SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVER CURRENT PROTECTION. WHERE WATER CLOSET COMPARTMENT IS INDEPENDENT OF THE BATHROOM OR SHOWER AREA, A FAN WILL BE REQ. IN EACH AREA. BATHROOMS SHALL HAVE AN EXHAUST FAN WITH HUMIDITY CONTROL SENSOR, MIN. 50 CFM CAPACITY. (CRC R303.3.1) THE MAX. AMOUNT OF WATER CLOSETS ON A 3" HORIZONTAL DRAINAGE SYSTEM LINE IS 5 (CPC TABLE 703.2) PROVIDE GAS LINES WITH A MN. CAPACITY OF 200,000BTU FOR WATER HEATER. (CAL ENERGY CODE 150.0(N)). WHERE WHOLE HOUSE FANS ARE USED IN BATHROOM AREAS, THE FAN MUST RUN CONTINUOUSLY AND SHALL NOT BE TIED TO HUMIDITY CONTROL SENSOR. (CAL GREEN 4.506.1) ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH HUMIDITY CONTROL SENSOR HAVING A MIN. CAPACITY OF 50 CFM DUCTED TO TERMINATE OUTSIDE THE BLDG. ( CRC R303.3, CAL GREEN 4.505.1, CBC 1203 .5.2.1, CMC 402.5 1. 2. 3. 4. 5. 6. 7. 8. 9. 11. 12. SUPPLY AND RETURN AIR DUCTS TO BE INSULATED AT A MIN. OF R-6. (CAL ENERGY CODE TABLE 150.1-A) ENVIRONMENTAL AIR DUCTS SHALL TERMINATE MIN. 3 FEET FROM PROPERTY LINE OR OPENINGS INTO BLDG., AND 10' FROM A FORCED AIR INLET. (CMC 502.2.1) ALL HOSE BIBS ARE TO HAVE VACUUM BREAKERS. (CPC603.5.7) THE MAX. AMOUNT OF WATER CLOSETS ON A 3" VERTICAL DRAINAGE LINE IS 5. (CPC TABLE 703.2) PROVIDE A CONDENSATE DRAIN NO MORE THAN 2" ABOVE THE BASE OF THE WATER HEATER SPACE. (CAL ENERGY CODE 150.0 (N). 10. ISOLATION VALVES ARE REQ. FOR TANKLESS WATER HEATERS ON THE HOT AND COLD SUPPLY LINES WITH HOSE BIBS ON EACH VALVE, TO FLUSH THE HEAT EXCHANGER. (CAL ENERGY CODE 110.3(7). 13. 14. 15. ALL EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. (CENC 150(K) 2B) PLUMBING FIXTURES AND FITTINGS INSTALLED IN RESIDENTIAL BUILDINGS SHALL COMPLY WITH THE PRESCRIPTIVE REQ. OF SECTIONS 4.303.1.1 THROUGH 4.303.1.4.4. PLUMBING FIXTURES AND FITTINGS REQ. IN SECTION 4.303.1 SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE AND SHALL MEET THE THE APPLICABLE REFERENCE STANDARDS. 16. 17. 10. 11. 12. 13. 15. 17. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED, THE SMOKE ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS IN THE INDIVIDUAL DWELLING UNIT. THE ALARM SHALL BE CLEARLY AUDIBLE IN ALL BEDROOMS OVER BACKGROUND NOISE LEVELS WITH ALL INTERVENING DOORS CLOSED. ALL EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEMS. (CENC 150(K) 2B) A MINIMUM OF ONE HIGH EFFICIENCY LUMINAIRE SHALL BE INSTALLED IN BATHROOM CONTROLLED BY AN OCCUPANT AND VACANCY SENSOR PROVIDING AUTOMATIC -OFF FUNCTIONALLY (CENC 150 .0(K)21) LAUNDRY AREA SHALL AT LEAST 1-20 AMP DEDICATED BRANCH CIRCUIT (CEC 210 .11 (C)(2) A DEDICATED 125V, 20AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRICAL PANEL WITH A 120 240 -VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS (CENC 150.0(N)1A) ELECTRICAL RECEPTACLE OUTLETS IN BATHROOM MUST BE NO MORE THAN 48 INCHES OR LESS THAN 15-INCHES MEASURE FROM THE FINISHED FLOOR. DOORBELL BUTTON MUST BE INSTALLED NO MORE THAN 48 INCHES FROM EXTERIOR FLOOR. 18. 14. PROVIDE A DEDICATED CIRCUIT FOR THE A.C./FAU (CEC 422.12) LUMINAIRE EFFICACY - ALL INSTALLED LUMINAIRES SHALL MEET THE REQUIREMENTS OF 2022 BUILDING ENERGY EFFICIENCY STANDARDS TABLE 150.0-A PER SECTION 150.0(K). 19. (S) ENERGY STORAGE SYSTEMS (ESS) READY. ALL SINGLE-FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING. ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE: 1. AT LEAST ONE OF THE FOLLOWING SHALL BE PROVIDED: A. ESS READY INTERCONNECTION EQUIPMENT WITH A MINIMUM BACKED-UP CAPACITY OF 60 AMPS AND A MINIMUM OF FOUR ESS-SUPPLIED BRANCH CIRCUITS, OR B. A DEDICATED RACEWAY FROM THE MAIN SERVICE TO A PANELBOARD (SUBPANEL) THAT SUPPLIES THE BRANCH CIRCUITS IN SECTION 150.0(S)(2). ALL BRANCH CIRCUITS ARE PERMITTED TO BE SUPPLIED BY THE MAIN SERVICE PANEL PRIOR TO THE INSTALLATION OF AN ESS. THE TRADE SIZE OF THE RACEWAY SHALL BE NOT LESS THAN ONE INCH. THE PANELBOARD THAT SUPPLIES THE BRANCH CIRCUITS (SUBPANEL) MUST BE LABELED “SUBPANEL SHALL INCLUDE ALL BACKED-UP LOAD CIRCUITS.” 2. A MINIMUM OF FOUR BRANCH CIRCUITS SHALL BE IDENTIFIED AND HAVE THEIR SOURCE OF SUPPLY COLLOCATED AT A SINGLE PANELBOARD SUITABLE TO BE SUPPLIED BY THE ESS. AT LEAST ONE CIRCUIT SHALL SUPPLY THE REFRIGERATOR, ONE LIGHTING CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS, AND AT LEAST ONE CIRCUIT SHALL SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET. 3. THE MAIN PANELBOARD SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. 4. SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3 FEET OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD AND THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. (U) ELECTRIC COOKTOP READY. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. 2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC COOKTOP INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” (V) ELECTRIC CLOTHES DRYER READY. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. 2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC CLOTHES DRYER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” (T) HEAT PUMP SPACE HEATER READY. SYSTEMS USING GAS OR PROPANE FURNACE TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOWING: 1. A DEDICATED 240 VOLT BRANCH CIRCUIT WIRING SHALL BE INSTALLED WITHIN 3 FEET FROM THE FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS “240V READY.” ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. 2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE HEAT PUMP SPACE HEATER INSTALLATION. THE RESERVED SPACE SHALL BE PERMANENTLY MARKED AS “FOR FUTURE 240V USE.” ELECTRIC READY NOTES: 2022 ENERGY EFFICIENCY STANDARDS 150.0 PER CEC 2022 150.0(N).1.A.: IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER, THEN THIS SPACE SHALL INCLUDE THE FOLLOWING:A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO OBSTRUCTIONS; AND · BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD "SPARE" AND BE ELECTRICALLY ISOLATED; AND· A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER FOR THE BRANCH CIRCUIT IN A ABOVE AND LABELED WITH THE WORDS "FUTURE 240V USE"; AND· A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. 16. ELECTRICAL NOTES (CONT'D) ALL HOSE CONNECTIONS SHALL BE EQUIPPED WITH NON-REMOVABLE BACK FLOW PREVENTERS. [CPC 603.3.3] 18. ELECTRICAL NOTES 1. 2. 3. 4. 5. 6. 7. RECEPTACLE OUTLET LOCATIONS WILL COMPLY WITH CEC ARTICLE 210.52. & CRC SECTION R327.1.2. TAMPER RESISTANT RECEPTACLE OUTLET LOCATIONS SHALL COMPLY W/ NEC ART. 210-52 AND 550.13 (I.E. ALL RECEPTACLES IN A DWELLING). PER LIGHTING MEASURES 150(K)4 N T-24, THE BEDROOMS, HALLWAY, LIVING ROOM AND OFFICE ARE REQUIRED TO HAVE ANY INSTALLED FIXTURE TO BE ON A DIMMER SWITCH AND THE FIXTURE NEEDS TO BE HIGH EFFICACY. OUTDOOR LIGHTING FIXTURES ARE REQUIRED TO BE HIGH EFFICACY AND CONTROLLED BY A COMBINATION PHOTOCONTROL / MOTION SENSOR. ARC-FAULT PROTECTION FOR ALL OUTLETS (NOT JUST RECEPTACLES) LOCATED IN ROOMS DESCRIBED IN NEC 210.12(A): KITCHENS, LAUNDRY AREAS, FAMILY, LIVING, BEDROOMS, DINING, HALLS, ETC. ALL BRANCH CIRCUITS WILL BE ARC FAULT CIRCUIT PROTECTED PER NEC ART. 210-12(B). MINIMUM OF 2–20-AMP CIRCUITS ARE REQUIRED TO SERVE THE KITCHEN COUNTERTOP OUTLETS. THESE CIRCUITS MAY ALSO SERVE THE PANTRY, BREAKFAST ROOM, DINING ROOM OR OTHER SIMILAR AREAS (210.52(B)(1) CEC) BATHROOM CIRCUITING SHALL BE EITHER: a) A 20 AMPERE CIRCUIT DEDICATED TO EACH BATHROOM. b) AT LEAST ONE 20 AMPERE CIRCUIT SUPPLYING ONLY BATHROOM RECEPTACLE OUTLETS PER NEC ART. 210-11(c)3. ALL 125-VOLT, SINGLE-PHASE, 15- AND 20- AMPERE RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, BASEMENTS, OUTDOORS, LAUNDRY AREA, KITCHEN DISHWASHERS, KITCHEN COUNTERS AND AT WET BAR SINKS, WITHIN 6' OF A SINK, SHALL BE GFCI PROTECTED PER NEC ART. 210-8(A). WEATHER RESISTANT TYPE FOR RECEPTACLES INSTALLED IN DAMP OR WET LOCATIONS (OUTSIDE) NEC 406.4(D)(6) 8. 9. SMOKE DETECTORS MUST BE PERMANENTLY WIRED. IN NEW CONSTRUCTION, REQUIRED SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING WHERE SUCH WIRING IS SERVED FROM A COMMERCIAL SOURCE AND SHALL BE EQUIPPED WITH A BATTERY BACK-UP. SMOKE ALARMS SHALL EMIT A SIGNAL WHEN THE BATTERIES ARE LOW. WIRING SHALL BE PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN AS REQUIRED FOR OVERCURRENT PROTECTION. A RECEPTACLE OUTLET MUST BE INSTALLED IN EVERY ROOM SO THAT NO POINT ALONG THE WALL SPACE IS MORE THAN 6 FEET, MEASURED HORIZONTALLY ALONG THE FLOOR LINE FROM A RECEPTACLE OUTLET CEC 210.52(A) gas service information:
X SELECTION UPGRADED SERVICE EXISTING SERVICE TO REMAIN NEW SERVICE ALL ELECTRICAL PROPANE "FIRE CLEARANCE REQUIRED" SIZE OF EXISTING SERVICE______________ SIZE OF NEW SERVICE______________________ electrical service information:X SELECTION UPGRADED SERVICE EXISTING SERVICE TO REMAIN (LOAD CALCS FOR THE EXISTING DWELLING IS REQUIRED) NEW SERVICE (NEW ADDRESS REQUIRED) SIZE OF EXISTING SERVICE______________ SIZE OF NEW SERVICE______________________ CONTACT SERVICE PROVIDER, REGARDING ELECTRIC SERVICES TO THIS DETACHED ADU. EXISTING SERVICE UPGRADE OR NEW SERVICE WILL REQUIRE A SEPARATE PERMIT FROM THE CITY OF EASTVALE. SPECIFICATIONS FOR EQUIPMENT SHALL BE KEPT ON SITE TO PROVIDE TO THE CITY OF EASTVALE BUILDING INSPECTOR ELECTRICAL SERVICE CHECKLIST GAS SERVICE CHECKLIST EXAMPLE GAS PIPE DIAGRAM DRAINAGE AND VENT PIPE DIAGRAM 2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant MEP.0 Mechanical/ Electrical/ Plumbing General Notes 27 February 2026 30 January 2026 457
MECHANICAL / PLUMBING PLAN 1/4"=1'-0" WD REF. DW BEDROOM BEDROOM LIVING BEDROOM CLOSET WH CLOSET CLOSET BATH BATH MP8 MP10 MP11 MP4 MP12 MP1 MP2 MP7MP6 MP5 MP13 MP3 MP6 MP14 MP6 MP9 MP6 MP2 MP7 MP5 MP1 MP1 MP1 MP15 MP9 MP2 MP16 IAQ FAN MP6 MP9 WD REF. DW BEDROOM BEDROOM LIVING BEDROOM CLOSET WH CLOSET CLOSET BATH BATH ELECTRICAL PLAN 1/4"=1'-0" E12 E1 E1 E5 E7 E10 E3E8E9 E14 E15 E4 E11 E16 E5 E16 E13 E11 E7 E6 E6 E6 E6 E6 E2 E6E6 E17 E20 E19 E18 EXHAUST HOOD ABOVE/ TO BE SMOOTH METALLIC INTERIOR SURFACE (CMC 504.3) HOSE BIB CONTROL VALVES IN SHOWERS, BATHTUBS, & BIDETS MUST BE PRESSURE BALANCED OR THERMOSTATIC MIX VALVES WATER CONSERVING FIXTURES: NEW WATER CLOSETS SHALL USE NO MORE THAN 1.28 GAL. OF WATER PER FLUSH, LAVATORIES LIMITED TO 1.2 GPM, KITCHEN FAUCETS NOT TO EXCEED 1.8 GPM AT 60 PSI THEY CAN INCREASE THE FLOW MOMENTARILY BUT CANT EXCEED 2.2GALLONS PER MIN. AT 60 PSI AND MUST DEFAULT TO A MAX. FLOW RATE OF 1.8GALLONS PER MIN AT 60 PSI., AND SHOWERS NOT EXCEED 1.8 GPM. AT 80 PSI AND ALL SHALL BE CERTIFIED TO MEET THE PERFORMANCE CRITERIA OF THE EPA WATERSENCE SPECIFICATIONS FOR SHOWERHEADS. CPC SECTIONS 407, 408, 411, 412 AND SECTION 301.1.1 CALGREEN CODE AND CIVIL CODE 1101.3(c) MINIMUM OF 3 FT CLEARANCE TO ANY OPENING INTO BUILDING FOR EXHAUST FAN TERMINATIONS MP1 CLEARANCE FOR WATER CLOSET TO BE A MIN. OF 24" IN FRONT, AND 15" FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION. (CPC 402.5) NEW NEEA RATED 40 GAL. HEAT PUMP WATER HEATER, RHEEM PROPH40-T2-RH375-SO (40 GA, JA13), TO HAVE CONDENSATE DRAIN INSTALLED NO HIGHER THAN 2' ABOVE THE BASE OF THE HEATER THAT ALSO ALLOWS GRAVITY DRAINAGE INDOOR UNIT MINI SPLIT SYSTEM. OUTDOOR CONDENSING UNIT ON A CONCRETE OR OTHER APPROVED BASE EXTENDING NOT LESS THAN 3 INCHES ABOVE THE ADJOINING GROUND LEVEL TO BE PIPED TO INDOOR HVAC UNIT THE 1/2" SIZE HOT WATER PIPE TO THE KITCHEN SINK AND THE COLD WATER PIPE WITHIN 5' OF WATER HEATER BOTH REQUIRE 1" INSULATION ALL DOMESTIC HOT WATER PIPING TO HAVE THE FOLLOWING MINIMUM INSULATION INSTALLED: 12" PIPE (12" INSULATION); 34" PIPE (1" INSULATION); 1" TO 1-1/2" PIPE (1-1/2" INSULATION) DRYER EXHAUST OUTLET FROM DRYER TO EXHAUST DIRECTLY TO EXTERIOR MAX LENGTH 14' WITH MAXIMUM OF TWO 90° ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90-DEGREE ELBOW IN EXCESS OF TWO. EXHAUST VENT MUST TERMINATE A MIN. OF 3' FROM ANY OPENING. MIN. TYPE 1 CLOTHES DRYER EXHAUST DUCTS SHALL BE OF RIGID METAL & SHALL HAVE SMOOTH INTERIOR SURFACES. THE DIAMETER SHALL BE NOT LESS THAN 4 INCHES NOMINAL (100 MM), & THE THICKNESS SHALL BE NOT LESS THAN 0.016 OF AN INCH (0.406 MM). EXHAUST DUCTS & DRYER VENTS SHALL BE EQUIPPED WITH BACK DRAFT DAMPERS NEW WATER HEATER TO BE INSTALLED ACCORDING TO MANUFACTURER'S REQUIREMENTS WITH T&P RELIEF VALVE AND DISCHARGE PIPE AT EXTERIOR. PROVIDE COMBUSTION AIR, CLEARANCES EQUAL TO ONE OPENING WITHIN 12 INCHES OF THE TOP OF THE ENCLOSURE AND ONE OPENING WITHIN 12 INCHES OF THE BOTTOM OF THE ENCLOSURE. EACH OPENING SHALL HAVE A MINIMUM FREE AREA OF 1 IN2 PER 1,000 BTU, BUT NOT LESS THAN 100 IN2, FOR ENCLOSURES OPENING INDOORS. (506.3 (1) CPC), AND ALL OTHER SPECIFICATIONS PER MANUFACTURER REQUIREMENTS. NEW WATER HEATERS SHALL HAVE ISOLATION VALVES ON BOTH THE COLD AND THE HOT WATER PIPING LEAVING THE WATER HEATER COMPLETE WITH HOSE BIBS OR OTHER FITTINGS ON EACH VALVES FOR FLUSHING THE WATER HEATER WHEN THE VALVES ARE CLOSED MECHANICAL / PLUMBING KEYNOTES MECHANICAL LEGEND EXHAUST FAN: MINIMUM 50 CFM TO BE DUCTED TO THE EXTERIOR AND SHALL PROVIDE FIVE AIR CHANGES PER HOUR; SECTION 1203.3. CFM AND NOISE RATING MAXIMUM 3 SONE FOR INTERMITTENT USE. SHALL BE ENERGY STAR RATED AND CONTROLLED BY A HUMIDISTAT CAPABLE OF AN ADJUSTMENT BETWEEN 50-80% HUMIDITY. ONE OR MORE FANS TO OPERATE CONTINUOUSLY AT REQUIRED CFM PER HERS NOTES ON T1.1(OR GREATER) TO PROVIDE INDOOR AIR QUALITY. AT THE IAQ FAN SWITCH, A LABEL CLEARLY DISPLAYING THE FOLLOWING OR EQUIVALENT TEXT IS REQUIRED: "THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION FOR THE HOME. LEAVE IT ON UNLESS THE OUTDOOR AIR QUALITY IS VERY POOR. MECHANICAL DUCT SYSTEMS ARE SIZED, DESIGNED AND EQUIPMENT IS SELECTED USING THE FOLLOWING METHODS.: 1. ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ANSI/ ACCA 2 MANUAL J-2011 OR EQUIVALENT. 2. SIZE DUCT SYSTEMS ACCORDING TO ANSI/ ACCA I MANUEL D-2014 OR EQUIVALENT. 3. SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ ACCA 3 MANUAL S-2014 OR EQUIVALENT . RETURN AIR GRILLE, WALL MOUNTED SUPPLY AIR DIFFUSER, WALL MOUNTED THERMOSTAT ELECTRICAL KEYNOTES SUBPANEL LOCATION. ALTERNATE LOCATION TO BE DETERMINED BY OWNER OUTLET AT COUNTER HEIGHT - SHALL COMPLY WITH CEC ARTICLE 210.52(C): IN KITCHENS A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH COUNTER SPACE 12" OR WIDER; SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL IS MORE THAN 24"; ISLAND IN PENINSULAR COUNTERTOPS 12" X 24" LONG (OR GREATER) SHALL HAVE AT LEAST ONCE RECEPTACLE OUTDOOR LIGHTING FIXTURES ARE REQUIRED TO BE HIGH EFFICACY CONTROLLED BY A COMBINATION PHOTOCONTROL / MOTION SENSOR. DEDICATED DUAL GFCI AND AFCI 30 AMP/ 240V POWER FOR ELECTRIC DRYER AND 50 AMP MINIMUM FOR DEDICATED COOKTOP BRANCH CIRCUIT CONDUCTOR. EACH APPLIANCE COVER PLATE IS TO BE LABELED AS ELECTRIC READY. VERIFY REQUIREMENTS WITH APPLIANCE SPECIFICATIONS - ELECTRIC COOKTOP READY REQUIREMENTS ARE TO BE IMPLEMENTED, SEE SHEET MEP.0, ELECTRIC READY 150.0(u) FOR REQUIREMENTS OUTLET DEDICATED FOR INDOOR MINISPLIT UNIT WEATHER RESISTANT TYPE RECEPTACLES GFCI PROTECTED AND SHALL HAVE EXTRA DUTY COVERS OVER-CURRENT FEEDER TO EXTEND TO EXISTING PANEL- ALUMINUM CONDUCTOR BURIED UNDER GROUND WITH AWG ALLOWABLE VOLTAGE DROP PER CEC 250.4 OUTLET FOR NEW ELECTRIC HYBRID HEAT PUMP WATER HEATER WITHIN 3' OF WATER HEATER. SEE ELECTRICAL NOTE #16 ON MEP.0 FOR MORE INFORMATION SEPARATE GROUND ELECTRODE SYSTEM PER CEC 250.4 OUTDOOR CONDENSING UNIT RECEPTACLE OUTLET SHALL BE INSTALLED AT AN ACCESSIBLE LOCATION FOR THE SERVICING OF THE HEATING AIR-CONDITIONING, AND REFRIGERATION EQUIPMENT AND SHALL BE LOCATED ON THE SAME LEVEL AND WITHIN 25 FEET OF THE EQUIPMENT. THIS RECEPTACLE SHALL BE 125-VOLT, SINGLE PHASE, 15 OR 20 AMP RATED GFCI-WP PROTECTED. A DISCONNECTING MEANS CAPABLE OF DISCONNECTING AIR-CONDITIONING AND REFRIGERATING EQUIPMENT, INCLUDING MOTOR-COMPRESSORS AND CONTROLLERS FROM THE CIRCUIT CONDUCTOR IS REQUIRED WITHIN SIGHT FROM THE EQUIPMENT LOCATION PER CEC SECTION 440.11 ELECTRICAL LEGEND SD 3 SWITCHING POWER/DATA FIRE DETECTION LIGHTING TAMPER RESISTANT RECEPTACLE WALL MOUNTED, 110 V DUPLEX U.O.N. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR SWITCH, MOUNT AT 43" AFF THREE-WAY SWITCH CEILING FAN/LIGHT COMBO PHONE / DATA / MEDIA CIRCUIT WIRING CEILING, RECESSED, ZERO CLEARANCE IC RATED LED BULB R CEILING, WATERPROOF OUTLET MISC. 4 FOUR-WAY SWITCH CM CARBON MONOXIDE ALARM PERMANENTLY WIRED WITH BATTERY BACKUP PER SECTION R315. ALARMS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL O F THE ALARMS IN THE UNIT. GFI = WATER PROOF GFCI J JUNCTION BOX FLUSH CEILING MOUNTED WALL MOUNTED LIGHT CT = COOKTOP/ GRILL 240 V O = OVEN 240 V MW = MICROWAVE 110 V GD = GARBAGE DISPOSAL 110 V R = RANGE 220V C = COUNTER HEIGHT 6" ABV COUNTER FLOOR MOUNTED DUPLEX RECEPTACLE, VERIFY LOCATION IN FIELD. SPECIAL PURPOSE CONNECTION (VOLTAGE SHALL MATCH APPLIANCE REQ.) D DIMMER SWITCH C MOUNT 6" ABV COUNTER SUB PANEL CEILING, RECESSED, DIRECTIONAL, ZERO CLEARANCE IC RATED LED BULB R IDU = INDOOR UNIT POWER 84" AFF CEILING, RECESSED, ZERO CLEARANCE IC RATED, WATER RESISTANT, LED BULB R W/D = WASHER/DRYER 30AMP/ 240AMP SMOKE DETECTORS PER SECTION R314 DETECTORS SHALL BE PERMANENTLY WIRED WITH BATTERY BACKUP. SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS. ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL O F THE ALARMS IN THE UNIT. SHALL COMPLY WITH THE FOLLOWING: · AT LEAST 3' FROM THE TIP OF THE BLADE OF A CEILING-MOUNTED FAN · NOT LESS THAN 3' FROM THE DOOR OPENING OF A BATHROOM · AT LEAS 20' FROM A COOKING APPLIANCE OR 10' FROM COOKING APPLIANCE WHEN THE ALARM IS AN IONIZING SMOKE ALARM PER NFPA 72 SECTION 29.8.3.4 ITEM 4 · AT LEAST 3' FROM SUPPLY REGISTERS OF A HEATING /COOLING SYSTEM LS LOW VOLTAGE, LANDSCAPE LIGHT FLUORESCENT FIXTURE (USE SHALLOW TYPE WHEN UNDER COUNTER) UNDER COUNTER LIGHTING PER CEC 2022 150.0(N).1.A.: THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER AND IS TO COMPLY WITH ELECTRICAL NOTES 15&16 ON SHEET MEP.0 MAIN PANELBOARD LOCATION SHALL HAVE A MINIMUM BUSBAR RATING OF 225 AMPS. DOOR BELL BUTTON MP2 MP3 MP4 MP5 MP6 MP7 MP8 MP9 MP10 MP11 MP12 MP13 MP14 E1E2E3E4E5E6E7E8E9 E10 E11 E12 E13 ALL SINGLE-FAMILY RESIDENCES THAT INCLUDE ONE OR TWO DWELLING UNITS SHALL MEET THE FOLLOWING ENERGY STORAGE SYSTEMS (ESS) READY REQUIREMENTS. ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CEC. SEE SHEET MEP.0, ELECTRIC READY 150.0(s) FOR REQUIREMENTS E14 E15 SUFFICIENT SPACE SHALL BE RESERVED TO ALLOW FUTURE INSTALLATION OF A SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH WITHIN 3FT OF THE MAIN PANELBOARD. RACEWAYS SHALL BE INSTALLED BETWEEN THE PANELBOARD & THE SYSTEM ISOLATION EQUIPMENT/TRANSFER SWITCH LOCATION TO ALLOW THE CONNECTION OF BACKUP POWER SOURCE. RESIDENTIAL ENERGY LIGHTING REQUIREMENTS:ES 150.0(K)/160.5(a) *IN THE KITCHEN, ALL OF THE WATTAGE RATING OF THE FIXTURES MUST BE HIGH EFFICACY. *BATHROOMS, GARAGES, LAUNDRY ROOMS, UTILITY ROOMS AND WALK-IN CLOSETS, AT LEAST ONE INSTALLED LUMINAIRE SHALL BE CONTROLLED BY AN OCCUPANCY OR VACANCY SENSOR PROVIDING AUTOMATIC-OFF FUNCTIONALITY. *ALL THROUGHOUT THE RESIDENCE, INCLUDING THE GARAGE AND EXTERIOR, SHALL BE HIGH EFFICACY. *OUTDOOR LIGHTING: ALL LUMINAIRES MOUNTED TO THE BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINAIRES AND SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION (W/ OVERIDE). BATHROOM EXHAUST FAN REQUIREMENTS:PER CGBC 4.506.1- EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING: 1. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. 2. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL. A. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF </= 50 % TO A MAXIMUM OF 80 %. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. B. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL(I.E. BUILT IN) S OCCUPANCY/VACANCY SENSOR A MINIMUM RATING HOOD OVER ELECTRICAL RANGE. INDOOR AIR QUALITY FAN IS REQUIRED IN THE KITCHEN AND SHALL BE HERS VERIFIED PER CEC TABLE 150.0-G: 160 cfm OR 65% CE AT <750 s.f, 130 cfm OR 55% CE AT 750-1000 s.f., 110 cfm OR 50% CE AT 1000-1500 s.f., OR 110 cfm OR 50% CE AT >1500 s.f. PROVIDE PLACARD AT THE IAQ SWITCH WHICH STATES "THIS FAN TO REMAIN ON DURING ALL HOURS THE HOUSE IS OCCUPIED" MP15 WATER HEATERS WITH STORAGE TANKS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL DISPLACE DUE TO EARTHQUAKE MOTION. STRAPPING SHALL BE AT POINTS WITH THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A MIN DISTANCE OF 4 IN SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING. E16 LIGHTS OVER TUBS AND SHOWERS ARE TO BE MARKED FOR DAMP/WET LOCATIONS WHERE SUBJECT TO SHOWER SPRAY MP16 MAKEUP AIR SHALL BE PROVIDED FOR TYPE I CLOTHES DRYERS IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AFCI ARC-FAULT CIRCUIT INTERRUPTEPER CEC 210.12 (A) ARC-FAULT CIRCUIT INTERRUPTER CEC 210.12 (A) R AFCI = ARC FAULT CIRCUIT INTERRUPTER 120-VOLT SINGLE PHASE, 15- AND 20 20-AMP BRANCH CIRCUIT PER CEC 210.12 (A) E17 LIGHTING OUTLET CONTAINING A SWITCH OR CONTROLLED BY A WALL SWITCH OR WALL MOUNTED CONTROL DEVICE AT EACH ATTIC ACCESS (210.70 (C) CEC) ATTIC ACCESS PANEL MIN SIZE TO BE 22"X30" AND TO HAVE ONE LIGHTING OUTLET WITH A SWITCH OR CONTROLLED BY A WALL SWITCH OR LISTED WALL MOUNTED CONTROL DEVICE E18 THE ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR THE FUTURE SOLAR ELECTRIC INSTALLATION. (CEnC 110.10 (b)B 4(e)) E19 LOCATION RESERVED FOR ROUTING OF CONDUIT FOR SOLAR ZONE E20 DRWR AFCI UCLV 2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant MEP.1 Mechanical/ Electrical/ Plumbing Plans 27 February 2026 30 January 2026 458
700. BUILDING CODE: 2022 CALIFORNIA BUILDING CODE AND 2022 CALIFORNIA RESIDENTIAL CODE. 701. SEISMIC DESIGN CRITERIA: SOIL BEARING VALUE 1,500 psf SITE CLASS D (Default) SEISMIC DESIGN CATEGORY D RISK CATEGORY II SEISMIC IMPORTANCE FACTOR 1 Ss: 1.850 Sds: 1.480 Cs: 0.207 S1: 0.670 Sd1: 0.759 R: 6.5 BASIC SEISMIC FORCE RESISTING SYSTEM:BEARING WALL ANALYSIS METHOD: EQUIVALENT LATERAL FORCE PROCEDURE SEE STRUCTURAL CALCULATIONS FOR SD1, SDS, DESIGN BASE SHEAR, Cs, & R FACTORS. 702. WIND DESIGN CRITERIA : WIND SPEED 126 mph RISK CATEGORY II EXPOSURE C INTERNAL PRESSURE COEF 0.18 703. DESIGN LOADING - WORST CASE LOADING: ROOF DL 18 psf l ROOF LL 20 psf PORCH DL 26 psf l PORCH LL 20 psf TRELLIS DL 6 psf l TRELLIS LL 10 psf SOLAR PANELS 3 psf 800. RETROFIT ANCHOR BOLTS FOR MISPLACED HOLDOWNS WITH ALL-THREAD ROD AND SIMPSON SET-XP EPOXY REQUIRE SPECIAL INSPECTION. (NO SPECIAL INSPECTION IS REQUIRED FOR RETROFIT ANCHOR BOLTS OR TITEN HD's WITHOUT A HOLDOWN ATTACHED.) 801. PER CBC 1705.3 SPECIAL INSPECTION IS NOT REQUIRED FOR NON-STRUCTURAL SLABS ON GRADE NOR FOR CONCRETE FOOTINGS THAT SUPPORT 3 STORIES ABOVE GRADE OR LESS. 802. PER CBC 1705.13 SPECIAL INSPECTION IS NOT REQUIRED FOR SEISMIC COMPONENTS FOR DETTACHED ONE- AND TWO-FAMILY DWELLINGS NOT EXCEEDING 2 STORIES ABOVE GRADE. 2. CONCRETE FOUNDATION CONSTRUCTION TYPE SHEARWALL SHEARWALL OR NON-SHEAR NON-SHEAR REPLACEMENT 58 " ALL-THREAD, EPOXY, EMBED 3" OR 5
8 " TITEN HD, EMBED 5
1 2 " MIN. 5
8 " TITEN HD, EMBED 5
1 2" MIN. 0.145 DIA. SHOT PINS SPACED 4 INCHES APART ON SILL. (2) FOR EACH MISSING ANCHOR BOLT. MAX. OF (6) SHOT PINS EVERY 6 FT. 200. 201. 202. 203. 204. 205. 206. 207. 208. 209. 210. 211. 212. 213. 214. 215. 216. THE FIELD INSPECTOR SHALL VERIFY FOUNDATION REQUIREMENTS DURING FOUNDATION INSPECTION. CONCRETE STRENGTH SHALL BE NO LESS THAN 2,500 PSI @ 28 DAYS, OR HIGHER STRENGTH IF NOTED ON THE PLANS. SLAB REINFORCEMENT & FOOTINGS SHALL BE PER STRUCTURAL DETAILS ON SHEET S2.1, CENTERED IN SLAB. REINFORCING BARS TO BE GRADE 40 FOR #3 BARS, GRADE 60 FOR #4 BARS & LARGER PROVIDE WEAKENED PLANE JOINTS FOR CRACK CONTROL (SAWCUT OR TOOLED JOINT) AT 14'-0" O/C MAX. SILL ANCHORAGE AT ALL SHEARWALL LOCATIONS SHALL BE PER THE SHEARWALL SCHEDULE. ALL SHEARWALL ANCHOR BOLTS SHALL RECEIVE A 3" SQUARE X 0.229" THICK WASHER. THE WASHER MAY BE DIAGONALLY SLOTTED (WIDTH >= BOLT DIAMETER + 316", LENGTH<=1 3 4") PROVIDED THAT A STANDARD CUT WASHER IS USED ON TOP OF THE SQUARE WASHER. SHEARWALL ANCHORS SHALL BE PLACED A MIN. OF 1 3 4" FROM THE EDGE OF CONCRETE. EMBEDDED SILL ANCHOR BOLTS AT TYPICAL NON-SHEARWALL CONDITIONS SHALL BE 58 " DIA. MIN. ANCHOR BOLTS WITH A STANDARD CUT WASHER. SPACING SHALL NOT EXCEED 48 INCHES O/C. LOCATE AN ANCHOR BOLT NOT MORE THAN 9 INCHES, OR LESS THAN 4" FROM ENDS AND SPLICES. EACH SILL SHALL HAVE (2) SILL BOLTS MIN. ANCHOR BOLTS SHALL BE EMBEDDED A MIN. OF 7 INCHES INTO CONCRETE. IN A TWO-POUR SYSTEM, ANCHOR BOLTS TO BE EMBEDDED 5 INCHES MIN. INTO FIRST POUR. SEE WOOD FRAMING CONSTRUCTION NOTES FOR ALTERNATE SILL ANCHORAGE. ALL HOLDOWNS SHALL BE PLACED A MINIMUM DIM AS SHOWN IN DETAIL 3&4/S2.1 FROM EXTERIOR CORNER OF SLAB. VERIFY ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS. SUBCONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. IMMEDIATELY NOTIFY HOMEOWNER AND CITY OF WILDOMAR OF ANY DISCREPANCY, TYPICAL. PROVIDE A UFER GROUND FOR ELECTRICAL SYSTEM PER ARTICLE 250.52 N.E.C. ALL SURROUNDING FLAT WORK SHALL BE VERIFIED WITH HOMEOWNER FOR LOCATION AND AMOUNT TO BE POURED. RETROFIT MISPLACED HOLDOWNS AS NOTED BELOW. AT EPOXY ANCHORS USE SIMPSON SET-3G EPOXY PER MANUFACTURERS INSTALLATION REQUIREMENTS AS FOLLOWS: MISPLACED HOLDOWN HDU2 HDU4 HDU5 HDU8 HDU11 RETROFIT 5 8 " EMBEDDED ANCHOR BOLTS AS NOTED BELOW. AT EPOXY ANCHORS USE SIMPSON SET-3G EPOXY PER SIMPSON'S INSTALLATION REQUIREMENTS. LOCATION SLAB EDGE, 1 3/4" DIST. INTERIOR > 6‚" EDGE DIST. ANY OTHER WHEN REQUESTING A BUILDING DEPARTMENT FOUNDATION INSPECTION, HAVE CONTRACTOR DOCUMENTATION IN WRITING FOR THE FOLLOWING: A) THE PAD WAS PREPARED IN ACCORDANCE WITH THE SITE REQUIREMENTS AND CITY OF WILDOMAR APPROVAL. B) THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED & COMPACTED. C) THE FOUNDATION EXCAVATIONS, EXPANSIVE CHARACTERISTICS AND BEARING CAPACITY COMPLIES WITH THE CITY OF WILDOMAR RECOMMENDATIONS . ALL HOLDOWN ANCHORS & HARDWARE MUST BE TIED IN PLACE PRIOR TO CALLING FOR A FOUNDATION INSPECTION. 3. WOOD FRAMING CONSTRUCTION (CONT.) 312. 313. 314. 315. 316. 305. 306. 307. 308. 309. 310. 311.HOLES, CUTOUTS, AND NOTCHES IN FRAMING MEMBERS: BY VIRTUE OF CODE COMPLIANCE WITH ELECTRICAL AND PLUMBING CODES, HOLES AND NOTCHES WILL INEVITABLY BE MADE IN FRAMING MEMBERS. THE CODE RECOGNIZES AND APPROVES VARIOUS HOLES AND NOTCHES WITHOUT ENGINEERING JUSTIFICATION IN CBC SECTION 2308.8.2. ENGINEERED (PSL, LSL) RECTANGULAR LUMBER BEAMS BEHAVE LIKE ANY OTHER RECTANGULAR SHAPE WHEN NOTCHED OR BORED, SO THE ENGINEER OR ARCHITECT MAY SPECIFY LIMITS WITHOUT MANUFACTURER APPROVAL OTHER HOLES AND NOTCHES ARE ALLOWED AS NOTED BELOW: PSL AND LVL BEAMS: A HOLE 1 INCH IN DIAMETER CAN BE DRILLED ANYWHERE, AND A 2 INCH DIA. HOLE CAN BE DRILLED IN THE MIDDLE THIRD OF THE SPAN IN THE MIDDLE THIRD OF THE DEPTH OF THE BEAM FOR ANY PSL OR LVL BEAM, EXCEPT CANTILEVERED BEAMS AND BEAMS SUPPORTING CONCENTRATED LOADS. HOLES IN THOSE CONDITIONS REQUIRE APPROVAL IN WRITING FROM THE ENGINEER. PSL AND LVL BEAMS: A RAKE CUT (TAPER) AT THE TOP OF THE BEAM AT THE END OF THE SUPPORT IS ALLOWED IF NOTED ON PLANS, TO A MINIMUM OF 4-3/8" AT INSIDE FACE OF SUPPORT. RAKE CUT (TAPER) THAT RESULTS IN A DEPTH AT THE INSIDE FACE OF THE SUPPORT OF 2/3RDS THE BEAM DEPTH IS ALLOWED AT CONDITIONS NOT SPECIFIED. OTHER TAPERED ENDS AND SQUARE NOTCHES IN TOP OR BOTTOM FACE REQUIRE APPROVAL IN WRITING FROM THE ENGINEER OR ARCHITECT. STUDS AND PLATES: SEE STRUCTURAL DETAILS 14 & 15 ON SHEET S2.1 FOR NOTCHING AND BORING. PROVIDE 2X4 TRIMMER & 2X4 KING STUD EACH END OF EACH 4X DROPPED BEAM OR HEADER. PROVIDE DOUBLE TRIMMERS AT EACH 4X10 OR LARGER. PROVIDE DOUBLE TRIMMERS AT EACH 3-1/2 X 7-1/2 PSL OR LSL OR LARGER. PROVIDE 2X6 TRIMMER & 2X6 KING STUD EACH END OF EACH 6X DROPPED BEAM OR HEADER. PROVIDE DOUBLE TRIMMERS AT EACH 6X8 OR LARGER. PROVIDE DOUBLE TRIMMERS AT EACH 5-1/4 X 7-1/2 PSL OR LSL OR LARGER. PROVIDE DOUBLE KING STUDS AT ALL OPENINGS 8'-1" WIDE AND WIDER OR PER PLAN. PROVIDE MINIMUM 2-1/4" BEARING @ EACH END OF EACH FLUSH BEAM OR HEADER WHERE BEARING IS ON TOP PLATE. PROVIDE 2X4 STUD WITHIN 3" OF BEARING POINT. PROVIDE (2) 2X STUDS @ 6X OR LSL OR PSL BEAMS. TYPICAL SHEAR TRANSFER: ROOF TO WALL: CONNECT ROOF FRAMING TO TOP PLATE W/ SIMPSON H1 @ 24" O/C OR A35 OR RBC @ 24" O/C OR PER SHEAR TRANSFER DETAILS. SILL PLATE ANCHORS: GROUND FLOOR / SLAB ON GRADE WALLS: PROVIDE 2X (MIN.) PTDF SILL PLATES. SEE CONCRETE FOUNDATION CONSTRUCTION NOTES 206, 207 & 208 FOR ANCHOR BOLTS. AT INTERIOR NON-SHEAR CONDITIONS, 0.145 SHOT PIN ANCHORS @ 32" O/C MAY BE USED TO CONNECT PARTITIONS AND BEARING WALLS TO SLAB. ALL WOOD SILL PLATES AND ALL WOOD MEMBERS DIRECTLY AGAINST CONCRETE OR MASONRY SHALL BE FOUNDATION GRADE REDWOOD SILLS OR PTDF SILLS, TREATED WITH SODIUM BORATE (SBX/DOT) WHEN INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT. (SODIUM BORATE TREATMENT DOES NOT REQUIRE CORROSION RESISTANT CONNECTORS.) IF OTHER TREATMENTS ARE USED, SEE NOTE 309. FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD: ALL NAILS AND FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER TREATED WITH ACQ-C, ACQ-D, CA-B, AND CBA-A WITHOUT AMMONIA SHALL BE GALVANIZED PER ASTM A153. ALL NAILS AND FASTENERS IN CONTACT WITH PRESSURE TREATED LUMBER TREATED WITH ACQ-C, ACQ-D, CA-B, AND CBA-A WITH AMMONIA SHALL BE TYPE 303, 304, 305, OR 316 STAINLESS STEEL. WHERE PRESSURE TREATED LUMBER IS INSTALLED IN AN EXTERIOR WET ENVIRONMENT, ALL NAILS AND FASTENERS IN CONTACT WITH THE PRESSURE TREATED LUMBER SHALL BE TYPE 303, 304, 305, OR 316 STAINLESS STEEL. RE-TIGHTEN ALL HOLDOWN ANCHORS JUST PRIOR TO COVERING THE WALL FRAMING. ENGINEERED BEAMS ARE AS FOLLOWS: "PSL" REFERS TO PARALLEL STRAND LUMBER (E=2.0, FB=2900). "LSL" REFERS TO LAMINATED STRAND LUMBER (E=1.55, FB=2325). (E=1.3 & FB=1700 AT LSL CONDITIONS WITH D (DEPTH) < 9" ) "LVL" REFERS TO LAMINATED VENEER LUMBER (E=2.0, FB=2800). "GLB" REFERS TO 24F-1.8E GLU-LAM WITH STANDARD CAMBER, U.N.O. "IJC" ENGINEERED GLU-LAM BEAM MAY BE USED UPON ENGINEER APPROVALS. AN A.I.T.C CERTIFICATE OF COMPLIANCE ISSUED BY A CURRENT ICC APPROVED QUALITY CONTROL AGENCY FOR GLUED LAMINATED WOOD MEMBERS SHALL BE GIVEN TO THE BUILDING INSPECTOR PRIOR TO INSTALLATION. LUMBER SPECIFICATIONS: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR-LARCH. STUDS, PLATES & BLOCKING: 2X4 FRAMING LUMBER NOT LISTED BELOW 92-1/4", 104-1/4", & 116-1/4" 2X4 STUDS 2X4 STUDS OVER 10' 2X4 SILLS & PLATES 2X6 STUDS, SILLS, & PLATES 4X4 STUDS & POSTS 4X6, 6X6, & LARGER STUDS & POSTS 4X4, 4X6 BEAMS & HEADERS 4X8, 4X10, 4X12, 4X14 BEAMS & HEADERS 6X4 BEAMS & HEADERS 6X6 & LARGER BEAM & HEADERS 2X10 AND LARGER RAFTERS AND JOISTS STANDARD GRADE OR BETTER STUD GRADE OR BETTER #2 OR BETTER STANDARD OR BETTER #2 OR BETTER STANDARD OR BETTER OR #1 #1 OR BETTER #2 OR BETTER #1 OR BETTER #2 OR BETTER #1 OR BETTER #1 OR BETTER 3. WOOD FRAMING CONSTRUCTION (CONT.) 3. WOOD FRAMING CONSTRUCTION 300. 301. 302. ROOFING MATERIALS SHALL BE PER ARCHITECTURAL DRAWINGS. ROOF SHEATHING SHALL BE 1932 " OR 5 8 " C-D GRADE, INTERIOR TYPE PLYWOOD WITH EXTERIOR GLUE, OR OSB PANELS. IDENTIFICATION INDEX (24/0) W/ 10D COMMON NAILS @ 6" O/C @ ALL PERIMETER EDGES AND ALL INTERIOR SUPPORTED EDGES AND @ 12" O/C @ ALL INTERMEDIATE SUPPORTS. SEE DETAILS FOR SHEAR AND DRAG NAILING. TYPICAL WALL SHEATHING: INTERIOR SURFACES: WHERE DRYWALL IS SPECIFIED, PROVIDE MIN. 5 8" GYPSUM WALLBOARD W/ 5D COOLER NAILS OR EQUAL @ 6" O/C TO ALL STUDS AND TO TOP & BOTTOM PLATES (UNBLOCKED) AT INTERIOR SIDE OF EXTERIOR WALLS AND AT BOTH SIDES OF ALL INTERIOR WALLS. EXTERIOR SURFACES: SEE PLANS. WHERE "STUCCO" IS SPECIFIED PROVIDE 7 8 " EXTERIOR CEMENT PLASTER OVER WIRE LATH OVER TYPE 15 BUILDING PAPER. LATH ATTACHED TO ALL STUDS AND TOP AND BOTTOM PLATES (OR BLOCKING AS OCCURS) W/ 16 GAGE X 716 " STAPLES @ 6" O/C OR NO. 11 GAGE X 1-1/2" FURRING NAILS WHERE INDICATED ON ELEVATIONS. 303. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. ANY NOTES REFERRING TO PLYWOOD ALSO APPLIES TO OSB. SHEATHING (WOOD STRUCTURAL PANELS) MUST MEET THE REQUIREMENTS OF DOC PS1 OR PS2 IN ACCORDANCE WITH NDS SDPWS. TOP PLATES SHALL BE DOUBLE 2X W/ WIDTH EQUAL TO STUDS BELOW, W/ (21)16D NAILS MIN. @ MINIMUM 4'-0" LAP SPLICES. USE SIMPSON RPS OR CS16 STRAP EACH SIDE OR ONE SIDE AND TOP WHERE LAP SPLICE IS NOT POSSIBLE. SEE DETAILS FOR NOTCHES, CUT-OUTS AND COMPLETE PLATE BREAKS AT HEATING, VENTING, AND PLUMBING. 6. NAILING SCHEDULE, MINIMUMS (CBC CHAPTER 23, TABLE 2304.10.2) 7. DESIGN CRITERIA 8. STATEMENT OF SPECIAL INSPECTIONS 9. SOILS REPORT 304. 317. 318. 319. ROOF RAFTERS SHALL BE 2X RAFTERS AS NOTED ON STRUCTURAL DRAWINGS EAVES SHALL BE PER ARCHITECTURAL PLANS W/ APPLIED TAILS PER ARCHITECTURAL PLANS. OVERHANG DETAILS ARE NOT SHOWN ON STRUCTURAL PLANS. SEE THE ARCHITECTURAL ROOF PLANS FOR ROOF PITCH AND ADDITIONAL INFORMATION. 320. COMBINE AND GROUP PLUMBING VENTS WHENEVER POSSIBLE TO MINIMIZE ROOF PENETRATIONS. WOOD STRUCT. PANELS, SUBFLOOR, ROOF AND INTERIOR WALL SHTNG TO FRMG AND BLKNG AT CEILING JOISTS, RAFTERS, OR TRUSSES TO TOP PLATE OR OTHER FRAMING, T.N. 4-8d Box, 3-8d Com, 3-10d box, 3-3" x 0.131" nails, 3-3" 14 gage staples BLKNG AT CEILING RAFTERS OR TRUSSES NOT AT WALL TOP PLATE TO RAFTER OR TRUSS, E.N. 2-16d Com, 3-3" x 0.131" nails, 3-3" 14 gage staples FLAT BLKNG TO TRUSS AND WEB, F.N. 16d Com, 3"x.131" nails, 3"x14 gage staples @ 6" o.c BLKNG AT CEILING RAFTERS OR TRUSSES NOT AT WALL TOP PLATE TO RAFTER OR TRUSS, T.N. 2-8d Com, 2-3" x 0.131" nails, 2-3" 14 gage staples CEILING JOISTS TO TOP PLATE, T.N. 4-8d box, 3-8d Com, 3-10d box, 3-3"x.131 nails, 3-3" 14 gage staples CEILING JOISTS NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITIONS, F.N. PER 2308.7.3.1 3-16d Com, 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples CEILING JOISTS ATTACHED TO PARALLEL RAFTER (HEEL JOINT), F.N. PER 2308.7.3.1 3-16d Com, 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples COLLAR TIE TO RAFTER, F.N. 3-10d Com, 4-10d box, 4-3"x0.131" nails, 4-3" 14 gage staples RAFTER/TRUSS TO TOP PLATE, T.N. PER TABLE 2308.7.3.5 3-10d Com, 3-16d or 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples RAFTERS TO RIDGE VALLEY OR HIP; OR FATER TO 2" RIDGE BEAM TOENAIL 4-16d box, 3-10d Com, 3-16d or 4-10d box, 4-3" x 0.131" nails, 4-3" 14 gage staples ENDNAIL 2-16d Com, 3-16d box, 3-10d box, 3-3" x 0.131" nails, 3-3" 14 gage staples STUD TO STUD (NOT AT BRACED WALL PANELS) 16d Com @ 24" o.c. FN OR 2-10d box, 3" x 0.131" nails, 3-3" 14 gage staples @ 16" o.c. FN STUD TO STUD AT INTERSECTING WALL CORNERS (BRACED WALL) 16d Com @ 16" o.c. FN OR 16d Box, 3" x 0.131" nails, 3-3" 14 gage staples @ 12" o.c. FN BUILT-UP HEADER (2" TO 2"), FN EA. EDGE 16d Com @ 16" o.c OR 16d Box @ 12" o.c. CONT. HEADER TO STUD, T.N. 4-8d Com, 4-10d Box, 5-8d box TOP PLATE TO TOP PLATE 16d Com @ 16" o.c. FN OR 10d Box, 3" x 0.131" nails, 3" 14 gage staples @ 12 o.c. FN TOP PLATE TO TOP PLATE, AT END JOINTS (EACH SIDE OF END JOINT), FACENAIL 24" MIN LAP SPLICE EA. SIDE 8-16d Com, 12-16d Box, 12-10d Box, 12-3" x 0.131" nails, 12-3" 14 gage staples BOTTOM PLATE TO JOIST, RIM, OR BLKG, FACENAIL UNBRACED WALL: 16" o.c. FN 16d Com UNBRACED WALL: 12" o.c. FN 16d Box, 3" x 0.131" nails, 3" 14 gage staples BRACED WALL: 16"o.c. FN 2-16d Com, 3-16d Box,4-3"x.131" nails,4-3" 14 gage staples STUD TO TOP OR BOTTOM PLATE TOENAIL 4-8d Box, 4x10d Box, 4-8d Com, 3-16d Box, 4-3"x0.131" nails, 4-3" 14 gage staples ENDNAIL 3-16d Box, 2-16d Com, 3-10d Box, 3-3"x0.131" nails, 3-3" 14 gage staples TOP PLATES, LAPS AT CORNERS AND INTERSECTION, F.N. 2-16d Com, 3-10d box, 3-3" x 0.131" nails, 3-3" 14 gage staples 1" BRACE TO EACH STUD AND PLATE, F.N. 3-8d Box, 2-8d Com, 2-10d Box, 2-3" x 0.131" nails, 2-3" 14 gage staples 1"x6" SHEATHING TO EACH BEARING, F.N. 3-8d Box, 2-1.75" 16 Gage staples, 2-8d Com, 2-10d Box 1"x8" SHEATHING AND WIDER TO EACH BEARING, F.N. 4-8d box, 4-1.75" 16 Gage staples, 3-8d Com, 3-10d Box JOIST TO SILL, TOP PLATE, OR GIRDER, T.N. 4-8d box, 3-8d Com, 3-10d Box, 3-3" x 0.131" nails, 3-3" 14 gage staples RIM JOIST, BAND JOIST, OR BLOCKING TO TOP PLATE, SILL OR OTHER 8d Box @ 4" o.c. TN OR 8d Com, 10d Box, 3" x 0.131" nails, 3" 14 gage staples @ 6" o.c. TN 1"x6" SUBFLOOR OR LESS TO EACH JOIST, F.N. 2-1.75" Gage Staples, 2-8d Com, 3-10d Box 2" SUBFLOOR TO JOIST OR GIRDER, F.N. or BLIND 3-16d Box, 2-16d Com 2" PLANKS (PLANK & BEAM - FLOOR & ROOF), FACENAIL & EACH BEARING 3-16d Box, 2-16d Com BUILT-UP GIRDERS AND BEAMS, 2" LUMBER LAYERS 32" o.c. FN Top & BTTM STAGGERED ON OPPOSITE SIDES 20d Com 24" o.c. FN Top & BTTM 10d Box, 3"x0.131" nails, 3" 14 gage staples ENDS & SPLICES, FN 2-20d Com, 3-10d Box, 3-3"x0.131" nails, 3-3" 14 gage staples LEDGER SUPPORTING JOISTS/RAFTERS 4-16d Box, 3-16d Com, 4-10d Box, 4-3"X0.131, 4-3" 14ga. STAPLES JOIST TO BAND OR RIM JOIST, END NAIL 3-16d Com, 4-10d Box, 4-3"X0.131, 4-3" 14ga. STAPLES BRIDGING OR BLOCKING TO JOIST, RAFTER OR TRUSS EACH END, T.N. 2-8d Com, 2-10d box, 2-3" x 0.131" nails, 2-3" 14 gage staples FOOTNOTES: a. Nails spaced at 6 inches at intermediate supports where spans are 48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shear walls, refer to Section 2305. Nails for wall sheathing are permitted to be common, box or casing. b. Spacing shall be 6 inches on center on the edges and 12 inches on center at intermediate supports for nonstructural applications. Panel supports at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise marked). c. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule and the ceiling joist is fastened to the top plate in accordance with this schedule, the number of toenails in the rafter shall be permitted to be reduced by one nail. d. RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. e. Tabulated fastener requirements apply where the ultimate design wind speed is less than 140 mph. For wood structural panel roof sheathing attached to gable-end roof framing and to intermediate supports within 48 inches of roof edges and ridges, nails shall be spaced at 4 inches on center where the ultimate design wind speed is greater than 130 mph in Exposure B or greater than 110 mph in Exposure C. Spacing exceeding 6 inches on center at intermediate supports shall be permitted where the fastening is designed per the AWC NDS. e. Fastening is only permitted where the ultimate design wind speed is less than or equal to 110 mph g. Nails and staples are carbon steel meeting the specifications of ASTM F1667. Connections using nails and staples of other materials, such as stainless steel, shall be designed by acceptable engineering practice or approved under Section 104.11. e 16d Com or deformed; or 2
38"x.113" nail (subfloor and wall) 8d Com or deformed (roof) or 2 38" x.113" nail (roof)d 1
3 4" 16 Ga Staple, 716" crown (subfloor and wall) 2
38" x.113"x.266" head nail (roof) 1
3 4" 16 Ga Staple, 716" crown (roof) EDGES (IN) INTERMEDIATE SUPPORTS (IN) 6 6 4
33 f
f e 12
6 833
f
f e 8d Com or deformed (subfloor and wall) 8d Com or deformed (roof) or 2 38" x.113" nail (roof) 2
38" x.113"x.266" head nail, 2"16 Gage staple, 716" crown 6 6 4
e 12
6 8
38"-1
2 " 1932"-3
4 " d
7 8"-1
1 4
" 10d Com or (3"x0.148"); or deformed (2
1 2 x.131"x.281 head) 6 12 OTHER EXTERIOR WALL SHEATHING (FIBERBOARD) 1 1 2" x0.120", galvanized roofing nail ( 716" head dia) or 1 1 4" 16 Ga Staple w/ 716" or 1" crown 1 3 6
2 "b 1
3 4" x0.120", galvanized roofing nail ( 716" head dia) or 1 1 2" 16 Ga Staple w/ 716 25 " or 1" crown 32
"b 3 6 WOOD STRUCTURAL PANELS, COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING 3 4" & LESS 8d COMMON (2 1
2"x0.131"); or deformed (2"x0.113"); or deformed (2"x0.120") 6 12 78"-1" 8d COMMON (2 1
2"x0.131"); or deformed (2"x0.113"); or deformed (2"x0.120") 6 12 1 1
8"-1
1 4
" 10d COMMON (3"x0.148"); or deformed (2
1 2"x0.131"); or deformed (2
1 2"x0.120") 6 12 PANEL SIDING TO FRAMING
1 2" & LESS 6d corrosion-resistant siding (1
78"x.106"); or 6d corrosion-resistant (2"x.099") 6 12
58 " 8d corrosion-resistant siding (2
38"x0.128"); or 8d corrosion-resistant casing (2
1 2"x0.113") 6 12 INTERIOR PANELING
1 4
" 4d casing (1
1 2"x0.080"); or 4d finish (1
1 2"x0.072") 6 12
38 " 6d casing (2"x0.099"); or 6d finish (2"x.092") - (Panel supports at 24 inches) 6 12 PARTICLEBOARD WALL SHEATHING TO FRAMING BEAM OR JOIST I-JOIST FLOOR JOISTS 1.75 X LSL AND LVL 2.69 X PSL AND LVL 3.5 X PSL AND LVL 5.25 X PSL AND LVL 7 X PSL AND LVL SIMPSON/USP HANGER IUS, IUT, OR ITT HANGERS HU, HUS, OR WPU HU OR HWU HHUS OR HWU HHUS OR HWU HHUS OR HWU 321. 322. 323. 324. 325. WOOD TO WOOD CONNECTORS SHALL BE SIMPSON STRONG TIE OR USP STRUCTURAL CONNECTORS. ALL SPECIFIED CONNECTOR CALL-OUTS ARE SIMPSON CATALOG CALL-OUTS. USP SUBSTITUTIONS SHALL HAVE A CAPACITY EQUAL TO OR GREATER THAN THE SIMPSON CATALOG VALUES. ANY OTHER ICC APPROVED METAL CONNECTOR MAY BE USED UPON APPROVAL BY THE ENGINEER OR ARCHITECT. ICC APPROVED CONNECTORS SHALL BE USED WHERE CONNECTORS ARE SPECIFIED. UNLESS OTHERWISE NOTED, THE FOLLOWING BEAM AND JOIST HANGERS SHALL BE USED: AT BEAM HANGER CALLOUTS, IE HGUS OR HU BEAMS, THE CALLOUT IS ABBREVIATED. THE HANGER WIDTH MAY BE OMITTED TO ALLOW FLEXIBILITY IN ORDERING. EXAMPLE: 2.69 PSL THE CALLOUT MAY READ HGUS12. AN HGUS2.75/12 OR HGUS412 (WITH FILLERS) ARE APPLICABLE. WHERE HANGERS OFFER (MIN) OR (MAX), NAIL TO APPLY (MAX) LOADS. WHERE SHEARWALL LENGTHS ARE SPECIFIED ON THE PLANS, THE LENGTH SHOWN IS A MINIMUM DIMENSION. THE SHEARWALL MAY BE LENGTHENED FOR CONSTRUCTION PURPOSES, BUT SHALL NOT BE REDUCED UNLESS OTHERWISE NOTED. ALL ENGINEERED WOOD PANEL SHEAR (PLYWOOD OR OSB) SHALL BE BLOCKED. THE FOLLOWING HOLES IN SHEARWALLS ARE ALLOWED: A) APPROXIMATELY SQUARE HOLES NOTCHED, PUNCHED, OR CUT THAT ARE LESS THAN 25 SQ. INCHES B) APPROXIMATELY SQUARE HOLES CLEAN CUT OR BORED IN SHEARWALLS THAT ARE LESS THAN 64 SQ. INCHES (ONE HOLE PER 4' OF SHEARWALL.) C) APPROXIMATELY SQUARE HOLES, LESS THAN 64 SQ. INCHES (ONE HOLE PER 8' OF SHEARWALL) WITH ALL EDGES BLOCKED & EDGE NAILED. D) HOLES INDIVIDUALLY APPROVED BY THE ENGINEER OR ARCHITECT OF RECORD. STUDS SHALL BE SPACED @ 16" O/C MAX. UNLESS OTHERWISE SPECIFIED. USE STUD GRADE FULL REPORTS FOUND AT: HTTP://WWW.ICC-ES.ORG 400. 401. 402. 403. PLYWOOD AND OSB PANELS: APA PLYWOOD & OSB--ESR-2586 JOISTS AND RAFTERS AND BEAMS: TRUS-JOIST TJI JOISTS AND PSL, LSL, & LVL--ICC-ES ESR-1387, 1153, BOISE CASCADE BCI JOISTS, VERSA-LAM, & VERSA-STRAND--ICC-ESR-1040, 1336 LOUISIANA PACIFIC JOISTS & BEAMS--ESR-1305, 2403 ROSEBURG JOISTS & BEAMS--ESR-1210, 1251 GLU-LAM BEAMS-- ESR-1940 PACIFIC WOOD TECH - ESR 2909 WOOD CONNECTORS: SIMPSON CONNECTORS--ICC-ES ESR #S 1161, 1622, 1866, 2105, 2203, 2236, 2320, 2549, 2551, 2552, 2553, 2330, 2554, 2555, 2604, 2605, 2606, 2607, 2608, 2611, 2613, 2614, 2615, 2616, 2877, 2920, 3046 IAPMO ER-112, 130, 143, 192, 262 USP LUMBER CONNECTORS--ICC-ES ESR #S 1178, 1280, 1575, 1702, 1781, 1881, 1970, 2104, 2685, 1831, 1465, 2761, 2787, IAPMO ER-200 QUICK DRIVE WOOD SCREWS--ICC-ES ESR-1472 ADHESIVES & ANCHORS: SIMPSON EPOXY-TIE HIGH STRENGTH EPOXY (SET-XP)--ICC-ES ESR-1772, 2508. SIMPSON WEDGE-ALL (WA) WEDGE ANCHORS--ICC-ES ES-1771 SIMPSON TITEN HD--ICC-ESR-1056, 2713 SIMPSON SHOT PINS ICC-ES ESR-2138 HILTI X-DN, X-ZF, X-CF SHOT PINS--ICC-ES ER-1663, 1752, 2269 5. NAILING & FASTENING 16D NAILS AS SHOWN ON THE DETAILS MAY BE COMMON, BOX, OR SINKER NAILS (0.135" MIN. DIA) AS AN ALTERNATE TO THE COMMON AND BOX NAILS SPECIFIED IN THE STRUCTURAL PLANS, THE FOLLOWING "CUTLER" GUN NAILS (OR EQUAL) ARE ACCEPTABLE ALTERNATIVES. ALTERNATE NAILING FOR ROOF SHEATHING: 8D 2 1 2 " X 0.135 WIRE BARBED NAILS BY CUTLER OR EQUAL. ALTERNATE NAILING FOR FLOOR SHEATHING: #8 X 2" SELF SETTING WOOD SCREWS, OR 8D 2 12 " X 0.135 OR 0.148 SCREW SHANK FLOOR NAILS BY CUTLER OR EQUAL SHEAR PANELS WHERE 8D COMMON NAILS ARE SPECIFIED: 10D 2 1 2 " X 0.148" WIRE BARBED NAILS BY CUTLER OR EQUAL 500. 501. 502. 503. 504. NAIL SIZES WIRE GAUGE 1211 101010 911 10998 SIZE OF NAIL 6D8D10D 12D 16D 16D SINKER 6D8D10D 12D 16D SIZE (INCHES) 0.099 0.113 0.128 0.128 0.135 0.148 0.113 0.131 0.148 0.148 0.162 PENETRATION REQUIRED 1" 1" 1" 1" 1" 1" 1" 1" 1 1 4
" 1
1 4
" 1
1 2
" BOX NAILS COMMON NAILS STANDARD LENGTH 2" 2" 3" 3" 3" 3" 2" 2 1 2 " 3" 3" 3" 326. ALL FINISHES, WATERPROOFING, DRAINAGE, AND FIRE-RELATED ELEMENTS ARE BY THE ARCHITECT OF RECORD AND ARE REQUIRED EVEN THOUGH THEY MAY NOT BE SHOWN ON THE STRUCTURAL PLANS AND DETAILS. 4. ICC-ES AND NER APPROVALS EXCEPT AT PLATE HEIGHTS HIGHER THAN 10'-0", THEN USE DF#2 OR BETTER 327. REDWOOD OR PRESSURE-TREATED LUMBER IS TO BE USED AT STRUCTURAL MEMBERS FOR BUILDING, BALCONIES, PORCHES OR SIMILAR APPURTENANCES WHEN EXPOSED TO THE WEATHER WITHOUT ADEQUATE PROTECTION OF A ROOF, EAVE, OVERHANG, OR OTHER COVERING TO PREVENT MOISTURE OR WATER ACCUMULATION. C&C PRESSURES ROOF: GABLE ROOF, PITCH α = 18.3° (-) ZONE 1 (-) ZONE 2 (-) ZONE 3 (+) ALL ZONES AEFFECTIVE = 10 sf 28 sf 30 sf -42.0 psf -39.5 psf -39.3 psf -50.6 psf -87.5 psf 16.5 psf -45.5 psf -76.0 psf 16.0 psf 16.0 psf -75.2 psf -45.1 psf WALLS (-) ZONE 4 (-) ZONE 5 (+) ZONE 4&5 AEFFECTIVE = 10 sf 21 sf 48 sf -1.28 psf -34.7 psf -32.9 psf -1.58 psf 1.00 psf -41.6 psf 31.9 psf 30.1 psf -38.0 psf A SOILS REPORT MAY BE REQUIRED BY THE BUILDING OFFICIAL. IN-LIEU OF THE SOILS REPORT A CONSERVATIVE VALUE FOR THE SOIL BEARING ALLOWABLE OF 1500 PSF HAS BEEN USED IN DESIGN OF THE BUILDING. REPLACEMENT HD HDU2 HDU4 HDU5 HDU8 HDU11 RETROFIT BOLT 5/8" ALL-THREAD, EMBED 6" 5/8" ALL-THREAD, EMBED 6" 5/8" ALL-THREAD, EMBED 9" 7/8" ALL-THREAD, EMBED 9" 1" ALL-THREAD, EMBED 12" MIN EDGE DISTANCE 2" 4.5" 6" 6" 7" 2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant Structural Notes & Specifications S0.1 27 February 2026 30 January 2026 30 January 2026 459
3 2 1
C
D
A
B 2x12's @ 24" o/c
3 1
2x14 LVL RIDGE BEAM
(2.0E MINIMUM) 12' 8' 6.7' 1/4"=1'-0" ROOF FRAMING PLAN 6x4 4x6 KING POST ECCQ46
5 CRAFTSMAN
4 23 S2.2 21 S2.2 22 S2.2 21 S2.2 24 S2.2
4 2x12's @ 24" o/c 2x12's @ 24" o/c 2x10's CJ @ 16" o/c 2.6' 6 27 S2.2 18 S2.1 TYP. 6x4 6x4 6x6
6x4 3.8' 4 21 S2.2 6x8 6x46x4 6x4 6x4 6x4 6x4
6x4 6x4 6x4
4 10.5' 2x12's @ 24" o/c 2x10's CJ @ 16" o/c 4x10 DF#1 CEILING BEAM 4x6 POST ECCQ46 24 S2.2 8'4
4x4
4x4 KING
POST
4x6 KING POST 12.5'4
5 6.6' 22 S2.2 22 S2.2 21 S2.2 22 S2.22x12's @ 24" o/c 2x12's @ 24" o/c 33 S2.2 33 S2.2 5'-0" MIN. BACKSPAN 5'-0" MIN. BACKSPAN 4x8 (MIN.)
4x8 (MIN.)
3 1
2x14 LVL CEILING BEAM
4x6 KING POST
4x4 KING POST 21 S2.2 23 S2.2
LUS210 HGRS 2x10's CJ @ 16" o/c
4x10 DF#1
4x6 KING
POST
4x12 DF#1
RIDGE BEAM
3 1
2x14 LVL RIDGE BEAM
(2.0E MINIMUM)
4x6 POST 19 S2.1 29 S2.2 24 S2.2 29 S2.2 36 S2.2 36 S2.2 37 S2.2 37 S2.2 6x4 6x8 INSPECTION NOTE: PER HERS SUMMARY FEATURES A QII (QUALITY INSULATION INSTALLATION) INSPECTION IS REQUIRED PRIOR TO DRYWALL INSTALLATION. 11 S2.1 TYP. BOLT TYPE HOLDOWN BEARING OR EXTENT HANGER TO BEAM/LEDGER SHEARWALL & A.B. SPACING PER SCHEDULE OF RAFTERS LEGEND BEARING OR EXTENT OF JOISTS X' * PLEASE REFER TO NOTES 311 & 401 ON S0.1 FOR LUMBER GRADE SPECIFICATIONS.
X SHEAR WALL SCHEDULE (ASD VALUES) SHEARWALL DESCRIPTION (See footnotes 1& 4) SHEAR VALUE (PLF) ANCHOR BOLT SPACING 260* 5 8" @ 48" or 1
2" @ 32" 5
8" @ 32" or 1
2" @ 24" 5
8" @ 24" or 1
2" @ 16" 5
8" @ 24" or 1
2" @ 16" 5
8" @ 16" or 1
2" @ 12" 5
8" @ 12" or 1
2" @ 8" SHEAR WALL FOOTNOTES (1) AT PLYWOOD OR OSB PS-1 OR PS-2 RATED PANELS USE COMMON NAILS OR GALVANIZED BOX NAILS (2) LAYERS OF PAPER EXTERIOR PLYWOOD REQUIRED. SHEARSHALL BE APPLIED OVER STUDS @ 16" O/C. GALVANIZED NAILS SHALL NOT BE HOT-DIPPED OR TUMBLED. (2) SILL PLATES & WASHERS SHALL COMPLY WITH THE CONCRETE FOUNDATION CONSTRUCTION AND WOOD FRAMING CONSTRUCTION NOTES. (SEE NOTES #206, 208, 209. 307, 308, 309, ETC.) (3) IN PLYWOOD SHEARWALLS, THE EDGE OF THE 3" SQUARE WASHERS (SEE NOTE #206) SHALL BE 1 2" OR LESS FROM THE EDGE OF THE SILL PLATE ON THE SIDE OF THE SHEATHING. ALL NAILING SHALL BE 3 8" MIN. FROM THE EDGE OF SHEATHING. (4) WHERE ALLOWABLE SHEAR VALUES EXCEED 350 PLF (SHEARWALL TYPES 6, 7, 8, & 9) ALL FRAMING RECEIVING NAILING FROM ABUTTING PANEL EDGES SHALL NOT BE LESS THAN A SINGLE 3" NOMINAL MEMBER OR (2) 2X MEMBERS NAILED WITH 10D , SPACING EQUAL TO THE E.N. SPACING. PLYWOOD JOINT AND SILL NAILING SHALL BE STAGGERED. (5) IN SHEARWALL TYPES 8 & 9, SILL PLATE NAILING SHALL BE STAGGERED. AT SECOND FLOOR CONDITIONS, PROVIDE ADEQUATE RIM OR BLOCKING TO PREVENT SPLITTING. (*) ALLOWABLE SHEAR VALUES FOR PLYWOOD SHEARWALLS MAY BE INCREASED BY 40% UNDER WIND LOADING. 375* 490* 550* 665* 870* SPACING OF A35/LTP4 FRAMING TO TOP PLATE 32" O.C. 16" O.C. 12" O.C. 12" O.C. 8" O.C. 8" O.C. 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 4" o/c edge, 12" o/c field, blocked (See footnote 3) 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3 & 4) 3 8" rated STRUCT 1 panel, (1) side w/ 8d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3 & 4) 15 32" rated STRUCT 1 panel, (1) side w/ 10d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3, 4, & 5) 15 32" rated STRUCT 1 panel, (1) side w/ 10d @ 2" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3, 4, & 5) 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 6" o/c edge, 12" o/c field, blocked (See footnote 3 ) 4 5 6 7 8 9 1. 2. 3.5. THE MINIMUM NOMINAL ANCHORBOLT DIAMETER SHALL BE 5/8 INCH NOTE: THIS WILL REQUIRE A MINIMUM DISTANCE FROM THE ENDS OF SILL PLATES TO BE 4" (AND A MAXIMUM OF 12") PLATE WASHERS (MINIMUM SIZE OF 3" x 3" x 1/4") SHALL BE USED ON EACH ANCHOR BOLT. ALL ANCHOR BOLTS, HOLDOWN ANCHORS, & REINF. MUST BE SECURELY TIED IN PLACE PRIOR TO FDTN. INSP. 6. SEE SHT S2.1 FOR TYP. CONCRETE & SLAB DETAILS 1-8 POSTS W/O SPECIFIED BASE SHALL BE NAILED TO BOLTED SILL PLATES W/ (2) 16d T.N. EA SIDE, TYP. PROVIDE CONC SLAB JOINTS AT NO MORE THAN 15 FT EA. WAY 4. 7. FOOTINGS ADJACENT TO SLOPES GREATER THAN OR EQUAL TO 33.3% SHALL COMPLY WITH SETBACK REQUIREMENTS DEFINED IN CBC 1808.7. 8. ALL EXTERIOR STUDS TO BE 2x6 @ 16" O.C. FOUNDATION NOTES INTERIOR HEADER SCHEDULE MAX OPENING MIN. HEADER MIN. GRADE 7'-0" 2x4 DF#2 9'-6" DBL 2x4 11'-0" 4x4 DF#2 DF#2 3 2 1
C
D
A
B
HDU2HDU2
HDU2
1'-0" 1'-0"
1'-0" 1'-0" 1/4"=1'-0" 4" CONC SLAB W/ #4 @ 18" O.C. AT MID-DEPTH OVER 10 MIL VAPOR BARRIER OVER 4" BASE ON PAD GRADE fc - 2500 PSI MIN (SPEC INSP NOT REQ'D). A 4-INCH-THICK (101.6 MM) BASE OF 1/2 INCH (12.7 MM) OR LARGER CLEAN AGGREGATE SHALL BE PROVIDED WITH A VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE AND A CONCRETE MIX DESIGN, WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING, SHALL BE USED. FOR ADDITIONAL INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. 5 FOUNDATION PLAN CRAFTSMAN
4x6 POST
1 S2.1
1 S2.1
1 S2.1
1 S2.1
8 S2.1
4 3 S2.1
3 S2.1
3 S2.1 TYP. 4
6 5 S2.1 2'-0" SQ. x 18" DEEP PAD FOOTING
HDU2 HDU2 3 S2.1
4 HDU2
HDU2
HDU2
3 S2.1
4 HDU2
3 HDU2 S2.1
4 1'-0" 1'-0" 1'-0" 1'-0"
1'-0" 4 HDU2
HDU2
HDU2
HDU2
HDU2
5 3 S2.1
HDU2
2 S2.1
2 S2.1
2 4 S2.1 S2.1
4x6 POST 5 S2.1 3'-0" SQ. x 18" DEEP PAD FOOTING w/ (5) No. 4 BARS EA. WAY 1'-0" HDU4
HDU4 2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant CRAFTSMAN FOUNDATION & FRAMING PLANS1.1 27 February 2026 30 January 2026 30 January 2026 460
BOLT TYPE HOLDOWN BEARING OR EXTENT HANGER TO BEAM/LEDGER SHEARWALL & A.B. SPACING PER SCHEDULE OF RAFTERS LEGEND BEARING OR EXTENT OF JOISTS X' * PLEASE REFER TO NOTES 311 & 401 ON S0.1 FOR LUMBER GRADE SPECIFICATIONS.
X SHEAR WALL SCHEDULE (ASD VALUES) SHEARWALL DESCRIPTION (See footnotes 1& 4) SHEAR VALUE (PLF) ANCHOR BOLT SPACING 260* 5 8" @ 48" or 1
2" @ 32" 5
8" @ 32" or 1
2" @ 24" 5
8" @ 24" or 1
2" @ 16" 5
8" @ 24" or 1
2" @ 16" 5
8" @ 16" or 1
2" @ 12" 5
8" @ 12" or 1
2" @ 8" SHEAR WALL FOOTNOTES (1) AT PLYWOOD OR OSB PS-1 OR PS-2 RATED PANELS USE COMMON NAILS OR GALVANIZED BOX NAILS (2) LAYERS OF PAPER EXTERIOR PLYWOOD REQUIRED. SHEARSHALL BE APPLIED OVER STUDS @ 16" O/C. GALVANIZED NAILS SHALL NOT BE HOT-DIPPED OR TUMBLED. (2) SILL PLATES & WASHERS SHALL COMPLY WITH THE CONCRETE FOUNDATION CONSTRUCTION AND WOOD FRAMING CONSTRUCTION NOTES. (SEE NOTES #206, 208, 209. 307, 308, 309, ETC.) (3) IN PLYWOOD SHEARWALLS, THE EDGE OF THE 3" SQUARE WASHERS (SEE NOTE #206) SHALL BE 1 2" OR LESS FROM THE EDGE OF THE SILL PLATE ON THE SIDE OF THE SHEATHING. ALL NAILING SHALL BE 3 8" MIN. FROM THE EDGE OF SHEATHING. (4) WHERE ALLOWABLE SHEAR VALUES EXCEED 350 PLF (SHEARWALL TYPES 6, 7, 8, & 9) ALL FRAMING RECEIVING NAILING FROM ABUTTING PANEL EDGES SHALL NOT BE LESS THAN A SINGLE 3" NOMINAL MEMBER OR (2) 2X MEMBERS NAILED WITH 10D , SPACING EQUAL TO THE E.N. SPACING. PLYWOOD JOINT AND SILL NAILING SHALL BE STAGGERED. (5) IN SHEARWALL TYPES 8 & 9, SILL PLATE NAILING SHALL BE STAGGERED. AT SECOND FLOOR CONDITIONS, PROVIDE ADEQUATE RIM OR BLOCKING TO PREVENT SPLITTING. (*) ALLOWABLE SHEAR VALUES FOR PLYWOOD SHEARWALLS MAY BE INCREASED BY 40% UNDER WIND LOADING. 375* 490* 550* 665* 870* SPACING OF A35/LTP4 FRAMING TO TOP PLATE 32" O.C. 16" O.C. 12" O.C. 12" O.C. 8" O.C. 8" O.C. 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 4" o/c edge, 12" o/c field, blocked (See footnote 3) 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3 & 4) 3 8" rated STRUCT 1 panel, (1) side w/ 8d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3 & 4) 15 32" rated STRUCT 1 panel, (1) side w/ 10d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3, 4, & 5) 15 32" rated STRUCT 1 panel, (1) side w/ 10d @ 2" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3, 4, & 5) 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 6" o/c edge, 12" o/c field, blocked (See footnote 3 ) 4 5 6 7 8 9 1. 2. 3.5. THE MINIMUM NOMINAL ANCHORBOLT DIAMETER SHALL BE 5/8 INCH NOTE: THIS WILL REQUIRE A MINIMUM DISTANCE FROM THE ENDS OF SILL PLATES TO BE 4" (AND A MAXIMUM OF 12") PLATE WASHERS (MINIMUM SIZE OF 3" x 3" x 1/4") SHALL BE USED ON EACH ANCHOR BOLT. ALL ANCHOR BOLTS, HOLDOWN ANCHORS, & REINF. MUST BE SECURELY TIED IN PLACE PRIOR TO FDTN. INSP. 6. SEE SHT S2.1 FOR TYP. CONCRETE & SLAB DETAILS 1-8 POSTS W/O SPECIFIED BASE SHALL BE NAILED TO BOLTED SILL PLATES W/ (2) 16d T.N. EA SIDE, TYP. PROVIDE CONC SLAB JOINTS AT NO MORE THAN 15 FT EA. WAY 4. 7. FOOTINGS ADJACENT TO SLOPES GREATER THAN OR EQUAL TO 33.3% SHALL COMPLY WITH SETBACK REQUIREMENTS DEFINED IN CBC 1808.7. 8. ALL EXTERIOR STUDS TO BE 2x6 @ 16" O.C. FOUNDATION NOTES INTERIOR HEADER SCHEDULE MAX OPENING MIN. HEADER MIN. GRADE 7'-0" 2x4 DF#2 9'-6" DBL 2x4 11'-0" 4x4 DF#2 DF#2 3 2 1
C
D
A
B 2x12's @ 24" o/c
3 1
2x14 LVL RIDGE BEAM
(2.0E MINIMUM) 12' 8' 6.7' 1/4"=1'-0" ROOF FRAMING PLAN 6x4 4x6 KING POST ECCQ46
5 4 23 S2.2 21 S2.2 22 S2.2 21 S2.2 24 S2.2 MONTEREY
4 2x12's @ 24" o/c 2x12's @ 24" o/c 2x10's CJ @ 16" o/c 2x6's @
24" o/c2.6' 6 18 S2.1 TYP. 6x4
6x4 6x6
6x4 3.8' 4 21 S2.2 6x8 6x46x4 6x4 6x4 6x4 6x4
6x4 6x4 6x4
4 10.5' 2x12's @ 24" o/c 2x10's CJ @ 16" o/c 4x10 DF#1 CEILING BEAM 4x6 POST ECCQ46 24 S2.2 8'4
4x4
4x4 KING
POST
4x6 KING POST 12.5'4
5 6.6' 22 S2.2 22 S2.2 21 S2.2 22 S2.2
3 1
2x14 LVL CEILING BEAM
4x6 KING POST
4x4 KING POST 21 S2.2 23 S2.2
LUS210 HGRS 2x10's CJ @ 16" o/c
4x10 DF#1
4x6 KING
POST
4x12 DF#1
RIDGE BEAM
3 1
2x14 LVL RIDGE BEAM
(2.0E MINIMUM)
4x6 POST 19 S2.1 29 S2.2 24 S2.2 29 S2.2 36 S2.2 36 S2.2 32 S2.2 4x6 DF#1 4x6 KNEE
BRACE
4x6 KNEE
BRACE 37 S2.2 37 S2.2 6x4 6x8 INSPECTION NOTE: PER HERS SUMMARY FEATURES A QII (QUALITY INSULATION INSTALLATION) INSPECTION IS REQUIRED PRIOR TO DRYWALL INSTALLATION. 11 S2.1 TYP. 3 2 1
C
D
A
B
HDU2HDU2
HDU2
1'-0" 1'-0"
1'-0" 1'-0" 1/4"=1'-0" 4" CONC SLAB W/ #4 @ 18" O.C. AT MID-DEPTH OVER 10 MIL VAPOR BARRIER OVER 4" BASE ON PAD GRADE fc - 2500 PSI MIN (SPEC INSP NOT REQ'D). A 4-INCH-THICK (101.6 MM) BASE OF 1/2 INCH (12.7 MM) OR LARGER CLEAN AGGREGATE SHALL BE PROVIDED WITH A VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE AND A CONCRETE MIX DESIGN, WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING, SHALL BE USED. FOR ADDITIONAL INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. 5 FOUNDATION PLAN
4x6 POST
1 S2.1
1 S2.1
1 S2.1
1 S2.1
8 S2.1
4 3 S2.1
3 S2.1
3 S2.1 TYP. MONTEREY
4 6
5 S2.1 2'-0" SQ. x 18" DEEP PAD FOOTING
HDU2 HDU2 3 S2.1
4 HDU2
HDU2
HDU2
3 S2.1
4 HDU2
3 HDU2 S2.1
4 1'-0" 1'-0" 1'-0" 1'-0"
1'-0" 4 HDU2
HDU2
HDU2
HDU2
HDU2
5 3 S2.1
HDU2
2 S2.1
2 S2.1
2 4 S2.1 S2.1
4x6 POST 5 S2.1 3'-0" SQ. x 18" DEEP PAD FOOTING w/ (5) No. 4 BARS EA. WAY 1'-0" HDU4
HDU4 2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant MONTEREY FOUNDATION & FRAMING PLANS1.2 27 February 2026 30 January 2026 30 January 2026 461
BOLT TYPE HOLDOWN BEARING OR EXTENT HANGER TO BEAM/LEDGER SHEARWALL & A.B. SPACING PER SCHEDULE OF RAFTERS LEGEND BEARING OR EXTENT OF JOISTS X' * PLEASE REFER TO NOTES 311 & 401 ON S0.1 FOR LUMBER GRADE SPECIFICATIONS.
X SHEAR WALL SCHEDULE (ASD VALUES) SHEARWALL DESCRIPTION (See footnotes 1& 4) SHEAR VALUE (PLF) ANCHOR BOLT SPACING 260* 5 8" @ 48" or 1
2" @ 32" 5
8" @ 32" or 1
2" @ 24" 5
8" @ 24" or 1
2" @ 16" 5
8" @ 24" or 1
2" @ 16" 5
8" @ 16" or 1
2" @ 12" 5
8" @ 12" or 1
2" @ 8" SHEAR WALL FOOTNOTES (1) AT PLYWOOD OR OSB PS-1 OR PS-2 RATED PANELS USE COMMON NAILS OR GALVANIZED BOX NAILS (2) LAYERS OF PAPER EXTERIOR PLYWOOD REQUIRED. SHEARSHALL BE APPLIED OVER STUDS @ 16" O/C. GALVANIZED NAILS SHALL NOT BE HOT-DIPPED OR TUMBLED. (2) SILL PLATES & WASHERS SHALL COMPLY WITH THE CONCRETE FOUNDATION CONSTRUCTION AND WOOD FRAMING CONSTRUCTION NOTES. (SEE NOTES #206, 208, 209. 307, 308, 309, ETC.) (3) IN PLYWOOD SHEARWALLS, THE EDGE OF THE 3" SQUARE WASHERS (SEE NOTE #206) SHALL BE 1 2" OR LESS FROM THE EDGE OF THE SILL PLATE ON THE SIDE OF THE SHEATHING. ALL NAILING SHALL BE 3 8" MIN. FROM THE EDGE OF SHEATHING. (4) WHERE ALLOWABLE SHEAR VALUES EXCEED 350 PLF (SHEARWALL TYPES 6, 7, 8, & 9) ALL FRAMING RECEIVING NAILING FROM ABUTTING PANEL EDGES SHALL NOT BE LESS THAN A SINGLE 3" NOMINAL MEMBER OR (2) 2X MEMBERS NAILED WITH 10D , SPACING EQUAL TO THE E.N. SPACING. PLYWOOD JOINT AND SILL NAILING SHALL BE STAGGERED. (5) IN SHEARWALL TYPES 8 & 9, SILL PLATE NAILING SHALL BE STAGGERED. AT SECOND FLOOR CONDITIONS, PROVIDE ADEQUATE RIM OR BLOCKING TO PREVENT SPLITTING. (*) ALLOWABLE SHEAR VALUES FOR PLYWOOD SHEARWALLS MAY BE INCREASED BY 40% UNDER WIND LOADING. 375* 490* 550* 665* 870* SPACING OF A35/LTP4 FRAMING TO TOP PLATE 32" O.C. 16" O.C. 12" O.C. 12" O.C. 8" O.C. 8" O.C. 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 4" o/c edge, 12" o/c field, blocked (See footnote 3) 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3 & 4) 3 8" rated STRUCT 1 panel, (1) side w/ 8d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3 & 4) 15 32" rated STRUCT 1 panel, (1) side w/ 10d @ 3" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3, 4, & 5) 15 32" rated STRUCT 1 panel, (1) side w/ 10d @ 2" o/c edge, 12" o/c field 3x abutting panel studs blocked (See footnote 3, 4, & 5) 3 8" ply. C-D or C-C sheathing, (1) side w/ 8d @ 6" o/c edge, 12" o/c field, blocked (See footnote 3 ) 4 5 6 7 8 9 1. 2. 3.5. THE MINIMUM NOMINAL ANCHORBOLT DIAMETER SHALL BE 5/8 INCH NOTE: THIS WILL REQUIRE A MINIMUM DISTANCE FROM THE ENDS OF SILL PLATES TO BE 4" (AND A MAXIMUM OF 12") PLATE WASHERS (MINIMUM SIZE OF 3" x 3" x 1/4") SHALL BE USED ON EACH ANCHOR BOLT. ALL ANCHOR BOLTS, HOLDOWN ANCHORS, & REINF. MUST BE SECURELY TIED IN PLACE PRIOR TO FDTN. INSP. 6. SEE SHT S2.1 FOR TYP. CONCRETE & SLAB DETAILS 1-8 POSTS W/O SPECIFIED BASE SHALL BE NAILED TO BOLTED SILL PLATES W/ (2) 16d T.N. EA SIDE, TYP. PROVIDE CONC SLAB JOINTS AT NO MORE THAN 15 FT EA. WAY 4. 7. FOOTINGS ADJACENT TO SLOPES GREATER THAN OR EQUAL TO 33.3% SHALL COMPLY WITH SETBACK REQUIREMENTS DEFINED IN CBC 1808.7. 8. ALL EXTERIOR STUDS TO BE 2x6 @ 16" O.C. FOUNDATION NOTES INTERIOR HEADER SCHEDULE MAX OPENING MIN. HEADER MIN. GRADE 7'-0" 2x4 DF#2 9'-6" DBL 2x4 11'-0" 4x4 DF#2 DF#2 3 2 1
C
D
A
B 2x12's @ 24" o/c
3 1
2x14 LVL RIDGE BEAM
(2.0E MINIMUM) 12' 8' 6.7' 1/4"=1'-0" ROOF FRAMING PLAN 6x4 4x6 KING POST ECCQ46
5 4 23 S2.2 21 S2.2 22 S2.2 21 S2.2 24 S2.2 FARMHOUSE
4 2x12's @ 24" o/c 2x12's @ 24" o/c 2x10's CJ @ 16" o/c 2.6' 6 18 S2.1 TYP. 6x4 6x4 6x6
6x4 3.8' 4 21 S2.2 6x8 6x46x4 6x4 6x4 6x4 6x4
6x4 6x4 6x4
4 10.5' 2x12's @ 24" o/c 2x10's CJ @ 16" o/c 4x10 DF#1 CEILING BEAM 4x6 POST ECCQ46 24 S2.2 8'4
4x4
4x4 KING
POST
4x6 KING POST 12.5'4
5 6.6' 22 S2.2 22 S2.2 21 S2.2 22 S2.2
3 1
2x14 LVL CEILING BEAM
4x6 KING POST
4x4 KING POST 21 S2.2 23 S2.2
LUS210 HGRS 2x10's CJ @ 16" o/c
4x10 DF#1
4x8 (MIN.) 5'-0" MIN. BACKSPAN 2x12's @ 24" o/c 2x12's @ 24" o/c 33 S2.2 33 S2.2 5'-0" MIN. BACKSPAN 4x6 KING
POST
4x12 DF#1
RIDGE BEAM
3 1
2x14 LVL RIDGE BEAM
(2.0E MINIMUM)
4x6 POST 19 S2.1 29 S2.2 24 S2.2 29 S2.2 36 S2.2 36 S2.2 37 S2.2 37 S2.2 4x8 HUC48
4x4 KP
HUC48 27 S2.2
4x8
(MIN.) 6x4 6x8 INSPECTION NOTE: PER HERS SUMMARY FEATURES A QII (QUALITY INSULATION INSTALLATION) INSPECTION IS REQUIRED PRIOR TO DRYWALL INSTALLATION. 11 S2.1 TYP. 3 2 1
C
D
A
B
HDU2HDU2
HDU2
1'-0" 1'-0"
1'-0" 1'-0" 1/4"=1'-0" 4" CONC SLAB W/ #4 @ 18" O.C. AT MID-DEPTH OVER 10 MIL VAPOR BARRIER OVER 4" BASE ON PAD GRADE fc - 2500 PSI MIN (SPEC INSP NOT REQ'D). A 4-INCH-THICK (101.6 MM) BASE OF 1/2 INCH (12.7 MM) OR LARGER CLEAN AGGREGATE SHALL BE PROVIDED WITH A VAPOR RETARDER IN DIRECT CONTACT WITH CONCRETE AND A CONCRETE MIX DESIGN, WHICH WILL ADDRESS BLEEDING, SHRINKAGE, AND CURLING, SHALL BE USED. FOR ADDITIONAL INFORMATION, SEE AMERICAN CONCRETE INSTITUTE, ACI 302.2R-06. 5 FOUNDATION PLAN
4x6 POST
1 S2.1
1 S2.1
1 S2.1
1 S2.1
8 S2.1
4 3 S2.1
3 S2.1
3 S2.1 TYP. FARMHOUSE
4 6
5 S2.1 2'-0" SQ. x 18" DEEP PAD FOOTING
HDU2 HDU2 3 S2.1
4 HDU2
HDU2
HDU2
3 S2.1
4 HDU2
3 HDU2 S2.1
4 1'-0" 1'-0" 1'-0" 1'-0"
1'-0" 4 HDU2
HDU2
HDU2
HDU2
HDU2
5 3 S2.1
HDU2
2 S2.1
2 S2.1
2 4 S2.1 S2.1
4x6 POST 5 S2.1 3'-0" SQ. x 18" DEEP PAD FOOTING w/ (5) No. 4 BARS EA. WAY 1'-0" HDU4
HDU4 2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant FARMHOUSE FOUNDATION & FRAMING PLANS1.3 27 February 2026 30 January 2026 30 January 2026 462
2025_Wildomar City of Wildomar Accessory Dwelling Units YSP/CRP/JDJG revisions project no. sheet no. drawn by date description project SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant 30 January 2026 S2.1 Structural Details27 February 2026 30 January 2026 30 January 2026 463
2025_Wildomar City of Wildomar Accessory Dwelling Units YSP/CRP/JDJG revisions project no. sheet no. drawn by date description project SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant 30 January 2026 Structural DetailsS2.2 27 February 2026 30 January 2026 30 January 2026 464
2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant Example Energy Calculations T24.1 27 February 2026 30 January 2026 30 January 2026 465
2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant Example Energy Calculations T24.2 27 February 2026 30 January 2026 30 January 2026 466
2025_Wildomar revisions project no. sheet no. drawn by date description project City of Wildomar Accessory Dwelling Units 30 January 2026 YSP/CRP/JDJG SEAL 40810 COUNTY CENTER DRIVE SUITE 200 TEMECULA, CA 92591 Consultant Example Energy Calculations T24.3 27 February 2026 30 January 2026 30 January 2026 467
City of Wildomar
Confidently plan and build your ADU with expert tips,
clear steps, and handy checklists—all in one easy-touse comprehensive guide This project is funded by Southern California Association of Governments (SCAG) Regional Early Action Program 2021 grant funding from the State of California 2026
468
Acknowledgments +
Contributors
CITY COUNCIL
Carlos Marquez, Mayor & District 1 Council Member
Dustin Nigg, Mayor Pro Tem & District 2 Council Member
Ashlee DePhillippo, District 5 Council Member
Joseph Morabito, District 3 Council Member
Bridgette Moore, District 4 Council Member
PLANNING COMMISSION
Nolan King, Chair
Dr. Charles Golden III, Vice-Chairperson
Eric Filar, Commissioner
John Hume, Commissioner
Rene Cambero, Commissioner
CITY MANAGEMENT
Chris Mann, City Manager
CITY STAFF
Robert Flores, Community Development Director
Scott Burns, Chief Building Official
Abdu Lachgar, Principal Planner
Joelle Perales, Planning Intern
CONSULTANT | MICHAEL BAKER INTERNATIONAL
Ashley Spinrad, Architect
Edward Hanbicki, Architect of Record
Olga Zaremba, Senior Architectural Designer
Alicia Gonzalez, Planning Manager
Carolyn Fahey, Senior Planner
FUNDING + SUPPORT
WHY USE THIS GUIDEBOOK?
This guidebook is designed to assist first-time building permit applicants in understanding the process of obtaining a permit from the City of Wildomar (City) for an accessory dwelling unit (ADU) or junior accessory dwelling unit (JADU). It identifies key references necessary for preparing an application, outlines the steps involved in the process, and notes common oversights to help applicants prepare effectively.
Note that when ADU is discussed generally, it is inclusive of JADUs as well.
NAVIGATING THIS GUIDEBOOK
This guidebook includes signposts or call-outs highlighting key information.
The material is organized according to the sequence of the building permit review process, and building permit applicants may find it helpful to read the document in its entirety before beginning their application.
Tools for putting together a building permit application, including detailed checklists, are included, as well as high level process overviews to help set expectations and allow for advanced planning.
Using this Guidebook
Useful links and tidbits found here!
Look out for blue boxes with helpful information.
469
What is an ADU
Benefits of ADUs
Getting Started
How Much Does an ADU Cost?
Getting a Building Permit
Pre-Approved ADU Program
FAQs
City Contacts
References
Glossary
Contents
79 11
17 22
27 55
57 58
59 Source: Google Earth
470
7City of Wildomar
ADU Guidebook
Generally speaking an accessory dwelling unit is a small apartment-type home that shares a property with an existing larger home, typically a traditional single-family home. They can be in many types, sizes, configurations, and locations. Many of these factors are determined by the State, who has written numerous pieces of legislation defining in detail what counts as an ADU.
ACCESSORY DWELLING UNIT. An ADU is a smaller home in relation to the primary home on a property, or a residence that is accessory to a primary residence. The ADU must have complete independent living facilities for one or more persons. ADUs can be “detached from,” “attached to,” or located within the proposed or existing primary dwelling. This includes attached garages, storage areas or similar spaces, and accessory structures. The ADU can also be detached from the proposed or existing primary dwelling, including detached garages, provided it is located on the same lot.
JUNIOR ACCESSORY DWELLING UNIT. A Junior Accessory Dwelling Unit (JADU) is a unit that is no more than 500 square feet in size and contained entirely within a single-family residence. A JADU may include separate sanitation facilities or may share sanitation facilities with the existing structure.
What is an ADU?
Source: Google Earth
Detached. Standalone Structure on
Existing Residential Property with Primary
Unit
471
8 9City of Wildomar
ADU Guidebook
Above Garage Addition. Addition
to Existing Garage.
Benefits of ADUs
PRIVATE BENEFITS
•ADUs can provide a source of income for homeowners.
•ADUs allow extended families to be near one another while maintaining privacy.
•ADUs give homeowners the flexibility to share independent living areas with family members and others, which can allow older adults to age in place or young adults to live at home with some 1 California Department of Housing and Community Development, Accessory Dwelling Unit Handbook: January 2025, September 9, 2025, p. 4.
ADUs are an affordable housing type that allow for increased housing options and opportunities. Their affordability combined with the relative ease with which one can be added to an existing residential property make it a significant contributor to addressing housing supply shortages across the State. According to the California Department of Housing and Community Development, in the last ten years the number of ADUs across the State has risen 20-fold, and 21% of all homes permitted in the State in 2023 were ADUs.1 The image below shows how a traditional single-family neighborhood can easily be developed with significantly more dwelling units by adding ADUs.
COMMUNITY BENEFITS
•ADUs are a flexible housing type that can be well-suited for individuals, couples, small families, friends, young people, and older adults alike.
•ADUs can provide as much living space as many newly built apartments and condominiums, and often provide ample private open space.
•ADUs are an affordable type of home to construct in California because the property already has electricity, water, sewer and other improvements.
•ADUs are often built with cost-effective wood frame construction, which is significantly less costly than a home in a new multifamily building.
Interior Conversion. Conversion
of Existing Finished Space within the
Existing Home.
Attached. Addition to
Existing Home
Garage Conversion. Conversion
of Existing Unfinished Garage
Space part of the Existing Home.
472
10 11City of Wildomar
ADU Guidebook
Getting Started
CAN I BUILD AN ADU ON MY PROPERTY?
It depends. The first thing to check when considering building an ADU on your property is what zoning district your property is located in. To find your property’s zoning district, navigate to the City of Wildomar Parcel Information Tool available on the City website. Type in your property address or Assessor’s Parcel Number (APN) into the search bar to locate your property. Then review the search results for your property’s zoning district. Generally speaking, ADUs are only permitted in residentially zoned districts, which are denoted with an “R” (e.g., RM or R1). For a comprehensive list of residentially zoned districts in the City, refer to Table 17.25.020-1 of the Wildomar Development Code.
DEVELOPMENT STANDARDS
Once you have determined whether an ADU is allowed on your property, you will need to check whether you can meet all the standards and requirements for siting an ADU on your property. The State has made these standards and requirements easy for homeowners to achieve, but there are a number of details to pay attention to elaborated in the table below. Make sure to confirm requirements with the Planning Department.
Find Your Zoning:
Use the City’s Parcel Information Tool to find your property’s zoning as well as other key information
Find Your Zoning Standards:
Use the City’s Municipal Code to find the development standards for your property’s zoning as well as other key information For Assistance with Planning +
Permitting Your ADU:
Contact a Planner at (951) 677-7751 or visit the Planning Department
Attached. Addition
to Existing Building.
Garage Conversion. Conversion
of Existing Unfinished Garage
Space part of the Existing Building.
Above Garage
Addition. Addition to
Existing Garage.
Interior Conversion. Conversion
of Existing Finished Space within the
Existing Building.
Detached. Standalone Structure on
Existing Residential Property with Primary
Unit.
473
12 13City of Wildomar ADU Guidebook
Development Standards Development Standards
Single-Family Residential. Low-density
residential typically comprised of detached
family homes with separate parcels
Multi-Family Residential. High-density
housing that is typically stacked apartment
or condominium units with an attached
parking structure or detached garages
Multi-Family Residential. Medium
density housing that is typically attached
townhomes or rowhomes with detached or
attached garages
Lot Line or Property Line. Defines the
extent of a property. Typically this line is
further back than the edge of sidewalk
or street in front of the home.
Utility Easement. Typically 5- to
7-foot wide area adjacent to the
property line where no structures can
be built
Principal Structure Buildable
Area. This is the area where a
principal structure can be placed.
This area is determined by setbacks
and utility easements.
Accessory Structure Buildable
Area. This is the area where a new
detached ADU can be placed. This
area is determined by setbacks and
utility easements. ADUs in Front Yard Setback.
Only permitted when there is no
feasible way to add an 800 sq ft ADU
elsewhere on the property
UNIT SIZE
Detached
Attached 50% of primary or maximum of
1,200 sq ft, whichever is less
Up to 1,200 sq ft
BUILDING HEIGHT
16 ft standard
8–20 ft near transit
25 ft max
All ADUs
ADU or JADU within
Existing Structure
No setbacks required for
conversions within existing living
area or accessory structures
SETBACKS + SEPARATION
New Attached or Detached
ADU
Max 4 feet from side and rear lot
lines
ADU Replacing Existing
Structure
No setbacks required if built in the
same location and to the same
dimensions
Front Yard Setback Allowed in Front Yard Setback but
only if 800 sq ft or less ADU
cannot fit elsewhere
Distance Between
Structures
Depending on zone district 7 or 10
feet where feasible
DESIGN STANDARDS
All ADUs Objective Design Standards
Garage Conversion No replacement parking required
PARKING
Standard ADU Max 1 space per unit or per
bedroom (whichever is less);
Parking may be provided in
tandem or within setbacks unless
infeasible due to topography or
fire/life safety
Efficiency Units + Studios
JADUs No parking required
No additional parking required
All ADUs No replacement parking is
required if garage or carport is
converted
DWELLING UNIT DENSITY
Single-Family 1 ADU + 1 JADU per property
Neighborhood
Up to 8 detached ADUs +
interior conversions of up to
25% the existing units
Multi-Family Development
ZONING DISTRICT
All ADUs Residential zones only
FIRE SPRINKLERS
If the existing residence has
sprinklers, the ADU will also be
required to provide sprinklers
Varies
BATHROOM
ADU Full bath
JADU May share with primary
UTILITIES
No new water, sewer, electric,
or gas service connection can
be required for conversions
All projects
KITCHEN
ADU Full kitchen
JADU Efficiency ktichen
2 1 In some instances three (3) J/ADUs can be achieved. 2 Up to eight (8) detached ADUs can be added to a multi-family property provided that the number of ADUs does not exceed the number of existing dwelling units on the property.
3 Local agencies cannot preclude an ADU of at least 800 sq ft even if the ADU would be within the front setback
Detached
Attached 50% of primary or maximum of
1,200 sq ft, whichever is less
Up to 1,200 sq ft
ADU or JADU within
Existing Structure
No setbacks required for
conversions within existing living
area or accessory structures
SETBACKS + SEPARATION
New Attached or Detached
ADU
Max 4 feet from side and rear lot
lines
ADU Replacing Existing
Structure
No setbacks required if built in the
same location and to the same
dimensions
Front Yard Setback Allowed in Front Yard Setback but
only if 800 sq ft or less ADU
cannot fit elsewhere
Distance Between
Structures
Depending on zone district 7 or 10
feet where feasible
DESIGN STANDARDS
All ADUs Objective Design Standards
Garage Conversion No replacement parking required
Efficiency Units + Studios
JADUs No parking required
No additional parking required
required if garage or carport is
converted
UTILITIES
All projects
3 1
474
14 15City of Wildomar ADU Guidebook
Development Standards
UNIT SIZE
Detached
Attached 50% of primary or maximum of
1,200 sq ft, whichever is less
Up to 1,200 sq ft
BUILDING HEIGHT
16 ft standard
8–20 ft near transit
25 ft max
All ADUs
ADU or JADU within
Existing Structure
No setbacks required for
conversions within existing living
area or accessory structures
SETBACKS + SEPARATION
New Attached or Detached
ADU
Max 4 feet from side and rear lot
lines
ADU Replacing Existing
Structure
No setbacks required if built in the
same location and to the same
dimensions
Front Yard Setback Allowed in Front Yard Setback but
only if 800 sq ft or less ADU
cannot fit elsewhere
Distance Between
Structures
Depending on zone district 7 or 10
feet where feasible
DESIGN STANDARDS
All ADUs Objective Design Standards
Garage Conversion No replacement parking required
PARKING
Standard ADU Max 1 space per unit or per
bedroom (whichever is less);
Parking may be provided in
tandem or within setbacks unless
infeasible due to topography or
fire/life safety
Efficiency Units + Studios
JADUs No parking required
No additional parking required
All ADUs No replacement parking is
required if garage or carport is
converted
DWELLING UNIT DENSITY
Single-Family 1 ADU + 1 JADU per property
Neighborhood
Up to 8 detached ADUs +
interior conversions of up to
25% the existing units
Multi-Family Development
ZONING DISTRICT
All ADUs Residential zones only
FIRE SPRINKLERS
If the existing residence has
sprinklers, the ADU will also be
required to provide sprinklers
Varies
BATHROOM
ADU Full bath
JADU May share with primary
UTILITIES
No new water, sewer, electric,
or gas service connection can
be required for conversions
All projects
KITCHEN
ADU Full kitchen
JADU Efficiency ktichen
Development Standards
UNIT SIZE
Detached
Attached 50% of primary or maximum of
1,200 sq ft, whichever is less
Up to 1,200 sq ft
ADU or JADU within
Existing Structure
No setbacks required for
conversions within existing living
area or accessory structures
SETBACKS + SEPARATION
New Attached or Detached
ADU
Max 4 feet from side and rear lot
lines
ADU Replacing Existing
Structure
No setbacks required if built in the
same location and to the same
dimensions
Front Yard Setback Allowed in Front Yard Setback but
only if 800 sq ft or less ADU
cannot fit elsewhere
Distance Between
Structures
Depending on zone district 7 or 10
feet where feasible
DESIGN STANDARDS
All ADUs Objective Design Standards
Garage Conversion No replacement parking required
PARKING
Standard ADU Max 1 space per unit or per
bedroom (whichever is less);
Parking may be provided in
tandem or within setbacks unless
infeasible due to topography or
fire/life safety
Efficiency Units + Studios
JADUs No parking required
No additional parking required
All ADUs No replacement parking is
required if garage or carport is
converted
Single-Family 1 ADU + 1 JADU per property
Neighborhood
Up to 8 detached ADUs +
interior conversions of up to
25% the existing units
Multi-Family Development
FIRE SPRINKLERS
If the existing residence has
sprinklers, the ADU will also be
required to provide sprinklers
Varies
BATHROOM
ADU Full bath
JADU May share with primary
UTILITIES
No new water, sewer, electric,
or gas service connection can
be required for conversions
All projects
Building Height. Most ADUs must be
no taller than 16 feet in overall height
Parking. In most cases an uncovered
parking space on the driveway can be
provided
Typical Full Kitchen. Has a sink,
full range, and typically an oven,
dishwasher, and refrigerator
Bathroom. A bathroom must have
a toilet and shower or shower/tub
combo
Typical Efficiency Kitchen. A sink,
cook top, and small refrigerator.
BUILDING HEIGHT
16 ft standard
8–20 ft near transit
25 ft max
All ADUs
DESIGN STANDARDS
All ADUs Objective Design Standards
Garage Conversion No replacement parking required
PARKING
Standard ADU Max 1 space per unit or per
bedroom (whichever is less);
Parking may be provided in
tandem or within setbacks unless
infeasible due to topography or
fire/life safety
Efficiency Units + Studios
JADUs No parking required
No additional parking required
All ADUs No replacement parking is
required if garage or carport is
converted
FIRE SPRINKLERS
If the existing residence has
sprinklers, the ADU will also be
required to provide sprinklers
Varies
BATHROOM
ADU Full bath
JADU May share with primary
UTILITIES
No new water, sewer, electric,
or gas service connection can
be required for conversions
All projects
KITCHEN
ADU Full kitchen
JADU Efficiency ktichen
5 4 Within 0.5-mile of public transit; In a historic district; Part of the existing or proposed primary residence or accessory structure; When on-street parking permits are required but not offered to the ADU occupant; When a car share vehicle is located within one block; When submitted with a permit for a new single- or multifamily dwelling
5 Local agencies may impose objective standards, but not if they unreasonably restrict ADU creation
4 475
16 17City of Wildomar ADU Guidebook
SHOULD I HIRE A PROFESSIONAL?
Development can be a daunting task, and many people opt to hire professionals to help them create an ADU application and navigate the permitting process.
Working with a licensed contractor, architect, engineer, landscape architect, and/or surveyor can provide invaluable guidance at various stages in the design and construction process. These licensed professionals offer different services that can help you with your project:
A Contractor is beneficial to build your unit. Often a contractor will work at a design build company that can provide design, engineering, landscaping, and surveying services in the form of a one-stop-shop service.
The contractor must be licensed by the State of California licensing board.
An Architect offers overall design, floor, and construction planning services.
A Designer offers services in design, floor, and sometime landscape design services, but are not licensed practitioners.
An Engineer offers structural calculations, utility design, site drainage and other services depending on the need and their area of specialty.
A Landscape Architect offers irrigation planning, landscapes layouts, plant selection, and existing trees care services.
A Surveyor offers services to locate your property line, which is essential to ensure construction does not occur in easements on your property or outside of your property line.
It is highly recommended that the professionals you hire for your ADU are licensed and that their references are checked prior to signing any contracts.
Despite being small in size, ADUs are significant investments. Ensuring a successful project that comes in on budget requires upfront budget planning.
The following estimate costs and fees is intended to provide an idea about which costs to consider for your ADU project that are on top of the labor and materials costs for construction.
ESTIMATING THE COST TO CREATE A BUILDING PERMIT
APPLICATION
One of the most significant costs besides construction itself is the cost to create a plan set, or a set of drawings showing what your ADU will look like, where it will be located, and how it will be constructed. Hiring an architect can cost anywhere between $3,000 to $10,000 to create the plans, provide revisions as needed, and assist with the permitting process. Alternatively, Pre-Approved Plan Sets are available from the City at no cost (see the Pre-Approved Plans section below).
PERMIT FEES
Permit fees cover the cost of City staff time to review the plans submitted.
Fees are collected at the time of building permit submittal, when revisions are submitted, when the final building permit is issued, and when the certificate of occupancy is issued. Consult with City staff on estimating total review and at which points of the review process fees are due.
How Much Does an ADU
Cost?
Source: City of Bakersfield
476
18 19City of Wildomar ADU Guidebook
Estimated Costs + Fees
DEVELOPMENT IMPACT FEES
Development impact fees cover the costs of the new housing unit on capital funds for roads, schools, utilities, emergency services, and other public services.
Only units sized 750 square feet and over are required to pay development impact fees at the time of building permit issuance.
INSPECTION FEES
Inspection fees cover the cost of staff time to travel to the project site, inspect the installation, and review the plans submitted. Fees are collected at the time when the final building permit is issued, and when the certificate of occupancy is issued. Consult with City staff on estimating total fees and at which points of the construction process fees are due.
CONNECTION FEES
Similar to impact fees, utility service providers collect what is called a connection fee to offset the costs of providing new services to a property. To determine connection fee amounts, reach out to the following entities as applicable:
FUNDING SOURCES
A variety of funding sources are available to assist with adding ADUs to existing properties, particularly in cases where the unit will be used to house low-income households or where the current property owner is considered low-income. Two key funding available for eligible property owners is the California Housing Finance Agency (CalHFA) ADU Grant Program, which provides direct funds to qualifying homeowners, and the CalHome Program, which provides grant funding to local jurisdictions and non-profits like Habitat for Humanity to build ADUs.
Potential ADU Funding Sources:
CalHFA | California Housing Finance Agency at
877.9.CalHFA or visit CalHFA
Habitat for Humanity | Call 951-787-6754, email Info@
HabitatRiverside.org or visit Riverside Habitat for Humanity up to $31,479 City Impact Fee – for units 750
square feet and over
DEVELOPMENT IMPACT FEES
$0 City Impact Fee – for units 749
square feet and under
$0 School Impact Fee - for units 500
square feet and under
$6,204 School Impact Fee - for units 501
square feet and over
PERMIT APPLICATION FEES
$0 Planning Fee
up to $5,759.57 Building Fee
PLAN SET COSTS
Custom plan set created for
property owner by an architect
$15,000
Pre-Approved Plan Set
available for use on the City
website
$0
$796 Riverside County Department of
Environmental Health only if a well
or septic tank is proposed
SERVICE CONNECTION FEES
$170 Elsinore Valley Municipal Water
District for water and sewer, unless
private water source is used
$(5,700) Southern California Edison costs
vary from $3,000 to 30,000
depending on the project. Projects
that expand existing service cost
roughly $3-5,000. If the ADU
proposes all electric energy, up
$5,700 can be credited toward
the service connection fee.
Please contact
Riverside County
Department of
Environmental Health
Riverside County Department of
Environmental Health - Varies.
Please contact to verify if your lot
qualifies for septic
Please contact
SoCal Gas
SoCal Gas - if gas will be used
INSPECTION FEES
Mechanical, Electrical,
Plumbing, Structural
up to $2,327.70
TOTAL EXPENSES
If the ADU is under 499 sq ft
and under, uses the
Pre-Approved Plan Set,
expands existing water, sewer,
and electric service, and uses
only electricity in the ADU
$4,748.13
If the ADU is 500 sq ft and over,
uses the Pre-Approved Plan Set,
expands existing water, sewer,
and electric service, and uses
only electricity in the ADU
$14,461.27
The example budget is intended to help create a ballpark estimate. Fees listed above are current as of November 2025. Please check with the City and service providers for an up-to-date estimate of applicable fees.
up to $31,479 City Impact Fee – for units 750
square feet and over
DEVELOPMENT IMPACT FEES
$0 City Impact Fee – for units 749
square feet and under
$0 School Impact Fee - for units 500
square feet and under
$6,204 School Impact Fee - for units 501
square feet and over
PERMIT APPLICATION FEES
$0 Planning Fee
up to $5,759.57 Building Fee
PLAN SET COSTS
Custom plan set created for
property owner by an architect
$15,000
Pre-Approved Plan Set
available for use on the City
website
$0
$796 Riverside County Department of
Environmental Health only if a well
or septic tank is proposed
SERVICE CONNECTION FEES
$170 Elsinore Valley Municipal Water
District for water and sewer, unless
private water source is used
$(5,700) Southern California Edison costs
vary from $3,000 to 30,000
depending on the project. Projects
that expand existing service cost
roughly $3-5,000. If the ADU
proposes all electric energy, up
$5,700 can be credited toward
the service connection fee.
Please contact
Riverside County
Department of
Environmental Health
Riverside County Department of
Environmental Health - Varies.
Please contact to verify if your lot
qualifies for septic
Please contact
SoCal Gas
SoCal Gas - if gas will be used
INSPECTION FEES
Mechanical, Electrical,
Plumbing, Structural
up to $2,327.70
TOTAL EXPENSES
If the ADU is under 499 sq ft
and under, uses the
Pre-Approved Plan Set,
expands existing water, sewer,
and electric service, and uses
only electricity in the ADU
$4,748.13
If the ADU is 500 sq ft and over,
uses the Pre-Approved Plan Set,
expands existing water, sewer,
and electric service, and uses
only electricity in the ADU
$14,461.27
The example budget is intended to help create a ballpark estimate. Fees listed above are current as of November 2025. Please check with the City and service providers for an up-to-date estimate of applicable fees.
477
20 21City of Wildomar
ADU Guidebook
RENTING YOUR ADU
Be sure get an accurate estimate of your ADUs potential rental income and factor in tax on rental income. Working with a reputable realtor should provide an accurate estimate of the potential rental income of your new ADU.
While you can check rental rates for similar units in your area using Zillow, Redfin and other rental listings, it is recommended that a realtor provide input on these estimates. Realtors can also work with you to rent the unit while it’s under construction to ensure the unit is rented as soon as the unit is inhabitable.
Income tax on rental payments runs between 10 to 37% of the income amount depending on the landlord’s overall income and filing status. A tax advisor can provide an accurate estimate of the income tax you will owe on your rental income, or you can run a mock tax return on readily available tax software for estimates.
Reach Out for Up-to-Date Fees:
BUILDING + SAFETY FEE SCHEDULE.
Building + Safety
*Note: Fees are updated annually. Applicants should check with the City for the most up-to-date fees.
SCHOOL FEES. Lake Elsinore Valley Unified School District at (951) 353-7015 or visit LEVUSD
WATER + SEWER SERVICE. Elsinore Valley Municipal Water
District (EVMWD) (951) 674-3146 or visit EVMWD
GAS SERVICE. Southern California Gas Company (SoCal
Gas) at (800) 228-7377 or visit SoCal Gas
ELECTRIC SERVICE. Southern California Edison (SCE or Edison) at (800) 644-4555 or visit SCE
HEALTH DEPARTMENT. County Department of Environmental
Health (RivCoEH) at (951) 955-8980 or visit RivCoEh
Source: City of Bakersfield
478
22 23City of Wildomar ADU Guidebook
Getting a Building Permit
Getting a building permit is collaborative process that involves conversation with City staff. Staff are committed to providing the guidance and support necessary for residents to successfully navigate the building permit process.
Here are some useful insights to further assist you as you prepare to submit a building permit application.
STEP 1
Complete building permit
application requirements
STEP 2
Submit application and pay
required fees
STEP 3
Respond to any City comments
in full and as quickly as possible
to facilitate quick approval of
your application
STEP 4
Obtain building permit and
pay remaining fees including
the development impact fees,
connection fees, and inspection
fees
STEP 6
Obtain certificate of
occupancy and move in!
STEP 5
Complete construction and
inspections at required intervals
PERMIT APPLICATION REQUIREMENTS
This section includes handy checklists to guide you through the key steps of submitting a building permit. You’ll find one for general requirements and another focused on the site plan. These lists aren’t all-inclusive, but they are a great starting point. Be sure to check in with City staff for any extra requirements that might apply to your project.
SUBMITTING YOUR PERMIT APPLICATION
Applicants can submit their permit online through the Building + Safety Department. Refer to the City’s Building + Safety Department webpage for the latest information on how to submit.
WHEN TO EXPECT A RESPONSE
Once a complete application is submitted and all plan check fees are paid, staff will review the application for compliance with the Municipal Code and Development Code. Reviewers from Planning, Building, Public Works, Engineering, Fire, Landscape, and other departments and divisions will review your application and provide a comment letter with any revisions necessary to reach full compliance. This process typically takes about two weeks from the time of submittal and is required to take no more than 15 days.
WHAT DO TO IF YOU RECEIVE COMMENTS FROM THE CITY
Once you have received a comment letter, the applications materials will need to be revised to address all the comments. Once the application materials have been revised, the materials can be resubmitted to the City for review. Typically a permit application receives one or two comment letters prior to building permit approval. However, the City is required to provide a final decision within 60 days of submitting your application.
Check Before You Apply:
Check the City’s Pre-Approved ADU Program webpage for the most up-to-date information on submitting a permit.
Pre-Approved Plans
479
24 25City of Wildomar ADU Guidebook
Application Checklist
BUILDING PERMIT APPLICATION
City-provided form with basic
property owner, property, and
project proposal information
Application Form
City-provided form that is only
required if an existing structure is
removed or altered as part of
the ADU construction
Demolition Permit
Application Form
Property owner letter describing
how the ADU will be used and
state whether the accessory
dwelling will be used for family
members or for rental purposes
Written Statement
Letter obtained from EVMWD
stating that the appropriate
water and sewerage availability
and capacity exist for the
proposed ADU
Will-Serve Letter
Custom plan set created for
property owner by an architect
or opt to use one of the City’s
Pre-Approved Plan Set
Site Plan
Custom plan set created for
property owner by an architect
or opt to use one of the City’s
Pre-Approved Plan Set
Elevations
Letter obtained from EVMWD
that their requirements have
been complied with
Verification Letter
SITE PLAN
Applicant name, address, and contact information
Property owner name, address, and contact
information, if different from applicant
Assessor’s parcel number of property where the ADU is
proposed
Property dimensions
Location and dimensions of all existing and proposed
structures
Location and dimensions of all easements, wells, septic tanks, leach lines, existing seepage pits, drainage
structures and utilities
Location, dimensions and names of all clear adjacent
roads, whether public or private, showing the location
of the street centerline and all existing improvements
such as sidewalks, curbs, gutters and curb cuts
Topography lines or location and direction of slope
Setbacks from all property lines
SITE PLAN (cont’d)
Methods of circulation, including ingress and egress,
access, yards, drives, parking areas, landscaping,
walls or fences
Independent exterior unit access from street. Access
cannot be provided from the interior of the primary
dwelling unit
Walls, landscaping, architectural treatments and other
methods which will be used to ensure that the
accessory dwelling unit will be compatible with the
neighborhood
Dwelling units 150 feet or more from a public
right-of-way shall be required to provide “all-weather
access” for emergency vehicles as required by the
Riverside County Fire Department
Indicate subpanel size and provide an electrical load
calculation for the existing panel to verify the capacity of the existing panel is sufficient to carry the load of the existing load and new subpanel
Required forms are
available on the Building
+ Safety Department
website
Pre-Approved Plans are
available on the City’s
PRADU website After You Submit Your Permit:
The City has 60 days to approve or deny your
application. If changes are needed, you’ll hear back
within 15 days—so you’ll never left wondering
what’s next!
Application Checklist
BUILDING PERMIT APPLICATION
City-provided form with basic
property owner, property, and
project proposal information
Application Form
City-provided form that is only
required if an existing structure is
removed or altered as part of
the ADU construction
Demolition Permit
Application Form
Property owner letter describing
how the ADU will be used and
state whether the accessory
dwelling will be used for family
members or for rental purposes
Written Statement
Letter obtained from EVMWD
stating that the appropriate
water and sewerage availability
and capacity exist for the
proposed ADU
Will-Serve Letter
Custom plan set created for
property owner by an architect
or opt to use one of the City’s
Pre-Approved Plan Set
Site Plan
Custom plan set created for
property owner by an architect
or opt to use one of the City’s
Pre-Approved Plan Set
Elevations
Letter obtained from EVMWD
that their requirements have
been complied with
Verification Letter
SITE PLAN
Applicant name, address, and contact information
Property owner name, address, and contact
information, if different from applicant
Assessor’s parcel number of property where the ADU is
proposed
Property dimensions
Location and dimensions of all existing and proposed
structures
Location and dimensions of all easements, wells, septic tanks, leach lines, existing seepage pits, drainage
structures and utilities
Location, dimensions and names of all clear adjacent
roads, whether public or private, showing the location
of the street centerline and all existing improvements
such as sidewalks, curbs, gutters and curb cuts
Topography lines or location and direction of slope
Setbacks from all property lines
SITE PLAN (cont’d)
Methods of circulation, including ingress and egress,
access, yards, drives, parking areas, landscaping,
walls or fences
Independent exterior unit access from street. Access
cannot be provided from the interior of the primary
dwelling unit
Walls, landscaping, architectural treatments and other
methods which will be used to ensure that the
accessory dwelling unit will be compatible with the
neighborhood
Dwelling units 150 feet or more from a public
right-of-way shall be required to provide “all-weather
access” for emergency vehicles as required by the
Riverside County Fire Department
Indicate subpanel size and provide an electrical load
calculation for the existing panel to verify the capacity of the existing panel is sufficient to carry the load of the existing load and new subpanel
480
26 27City of Wildomar ADU Guidebook
Pre-Approved ADU
Program
The City’s Pre-Approved ADU Program provides pre-approved ADU plans that have been made available to the public for free so that anyone can use them. Through the Pre-Approved ADU Program, the City provides free ADU plans that have been pre-approved by City staff so the permit review process is streamlined. These plans are a great benefit to the community as they save the property owner significant costs and time. Property owners do not need to pay private consultants to create a plan set for them, they do not need to spend time in design development, and because the Pre-Approved Plans have already been reviewed by the City, they reduce the amount of time their permit application is in review.
PRE-APPROVED ADU PLAN SETS
Here’s a look at the City’s pre-approved building plans. You can choose from three architectural styles with options for a studio, 1, 2, or 3 bedrooms—and two porch designs. Full plans are just a click away on the City website, with links right next to each preview.
USING PRE-APPROVED PLANS
Pre-Approved Plans are simple and easy to use. Start by selecting an architectural style, then a floor plan, and then following the permit review procedures at the end of this section.
Pre-Approved Plans are
available on the City’s
PRADU website
Source: Google Earth
481
28 29City of Wildomar ADU Guidebook
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
Unit Size
STUDIO
493 Square Feet
1 BEDROOM
646 Square Feet
Next select which unit layout you prefer. There are six different layouts with a variety of bedroom numbers. Also available is the option to add a front porch.
Architectural Style
The Pre-Approved Plans are all available in one of the three styles shown below. Select which of the three styles you prefer.
2 BEDROOM
749-1086 Square Feet
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
3 BEDROOM
994-1195 Square Feet
CRAFTSMAN MONTEREY MODERN FARMHOUSE
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
482
30 31City of Wildomar
ADU Guidebook
Craftsman | Studio
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
STUDIO
493 Square Feet
Craftsman | 1 Bedroom
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
1 BEDROOM
646 Square Feet
483
32 33City of Wildomar ADU Guidebook
Craftsman | 2 Bedroom Option A
2 BEDROOM | Option A
749 Square Feet
Craftsman | 2 Bedroom Option A w/Porch
2 BEDROOM | Option A w/Porch
1104 Square Feet
REF.
135 SF
BEDROOM
136 SF
BEDROOM
BATH
LIVING
KITCHEN
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
14' - 9"
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
484
34 35City of Wildomar ADU Guidebook
Craftsman | 2 Bedroom Option B
2 BEDROOM | Option B
1139 Square Feet
Craftsman | 3 Bedroom Option A
3 BEDROOM | Option A
994 Square Feet
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
D W
REF.
LIVING
BATH
BATH
KITCHEN
ALTERNATE
WALK-IN CLOSET
126 SF / 150 SF
BEDROOM
130 SF
BEDROOM
31' - 0"
34' - 0"
485
36 37City of Wildomar ADU Guidebook
Craftsman | 3 Bedroom Option A w/Porch Craftsman | 3 Bedroom Option B 3 BEDROOM | Option A w/Porch
1104 Square Feet
3 BEDROOM | Option B
1195 Square Feet
D
W
REF.
BEDROOM
154 SF
BEDROOM
144 SF
BEDROOM
LIVING
BATH
BATH
KITCHEN
31' - 0"
43' - 0"
15' - 4" 15' - 8"
9' - 0" 34' - 0"
126 SF / 150 SF
27' - 10"
ALTERNATE
WALK-IN CLOSET
REF.
BATH 143 SF
BEDROOM
151 SF
BEDROOM
146 SF
BEDROOM
LIVING
KITCHEN
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
15' - 1 1/2"
486
38 39City of Wildomar ADU Guidebook
Monterey | Studio
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
STUDIO
493 Square Feet
Monterey | 1 Bedroom
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
1 BEDROOM
646 Square Feet
487
40 41City of Wildomar
ADU Guidebook
Monterey | 2 Bedroom Option A
2 BEDROOM | Option A
749 Square Feet
Monterey | 2 Bedroom Option A w/Porch
2 BEDROOM | Option A w/Porch
1067 Square Feet
REF.
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
14' - 9"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
488
42 43City of Wildomar ADU Guidebook
Monterey | 2 Bedroom Option B Monterey | 3 Bedroom Option A 2 BEDROOM | Option B
1054 Square Feet
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
3 BEDROOM | Option A
994 Square Feet
D W
REF.
LIVING
BATH
BATH
KITCHEN
126 SF / 150 SF
BEDROOM
BEDROOM
31' - 0"
34' - 0"
130 SF
ALTERNATE
WALK-IN CLOSET
489
44 45City of Wildomar ADU Guidebook
Monterey | 3 Bedroom Option A w/Porch Monterey | 3 Bedroom Option B 3 BEDROOM | Option A
1067 Square Feet
3 BEDROOM | Option B
1195 Square Feet
D W
REF.
BEDROOM
154 SF
BEDROOM
144 SF
BEDROOM
LIVING
BATH
BATH
KITCHEN
31' - 0"
43' - 0"
15' - 4" 15' - 8"
9' - 0" 34' - 0"
126 SF / 150 SF
27' - 10"
ALTERNATE
WALK-IN CLOSET
REF.
BATH
LIVING
KITCHEN
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
15' - 1 1/2"
490
46 47City of Wildomar ADU Guidebook
Modern Farmhouse | Studio
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
STUDIO
493 Square Feet
Modern Farmhouse | 1 Bedroom
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
1 BEDROOM
646 Square Feet
491
48 49City of Wildomar ADU Guidebook
Modern Farmhouse | 2 Bedroom Option A
2 BEDROOM | Option A
749 Square Feet
Modern Farmhouse | 2 Bedroom Option A w/Porch
2 BEDROOM | Option A w/Porch
1086 Square Feet
REF.
LIVING
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
14' - 9"
BEDROOM BEDROOM
BATH
KITCHEN
135 SF 136 SF
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
492
50 51City of Wildomar
ADU Guidebook
Modern Farmhouse | 3 Bedroom Option A
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
3 BEDROOM | Option A
994 Square Feet
Modern Farmhouse | 2 Bedroom Option B
2 BEDROOM | Option B
1123 Square Feet
D W
REF.
LIVING
BATH
BATH
KITCHEN
126 SF / 150 SF
BEDROOM
BEDROOM
31' - 0"
34' - 0"
130 SF
ALTERNATE
WALK-IN CLOSET
493
52 53City of Wildomar ADU Guidebook
Modern Farmhouse | 3 Bedroom Option B
3 BEDROOM | Option B
1195 Square Feet
Modern Farmhouse | 3 Bedroom Option A w/Porch
3 BEDROOM | Option A w/Porch
1086 Square Feet
REF.
BATH
LIVING
KITCHEN
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
15' - 1 1/2"
D W
REF.
BEDROOM
154 SF
BEDROOM
144 SF
BEDROOM
LIVING
BATH
BATH
KITCHEN
31' - 0"
43' - 0"
15' - 4" 15' - 8"
9' - 0" 34' - 0"
126 SF / 150 SF
27' - 10"
ALTERNATE
WALK-IN CLOSET
494
54 55City of Wildomar ADU Guidebook
KEY STEPS
Review available plans to determine whether they
would work on your property. If you are unsure or have
questions, contact the Planning Department.
Download your selected Pre-Approved Plan Set and
required application form(s)
Make the Pre-Approved Plan Set your own by
completing the required fields in the Pre-Approved Plan Set and selecting any options available in the plans
Complete and sign the Pre-Approved Plan Set and
application form(s)
Submit the completed Pre-Approved Plan Set,
application form(s), and fees to the Building + Safety
Department for review
Respond to City review comments and resubmit
Once the application is ready for approval, any JADUs
are required to complete a Deed Restriction that is
recorded on the property
Complete an address application for the new unit as
required
1 2
3 4
5 6
7 8
The City will issue your building permit once the permit application has been approve, any deeds are
recorded, and fees are paid
Construct your ADU
Have the construction inspected as required by the
Building + Safety Department
Once the inspections have been completed and final
fees have been paid, a Certificate of Occupancy will
be issued
Congratulations on your new ADU! You can now move
in.
9 10
11 12
13 Pre-Approved Plan
Permit Review
FAQs
WHAT IS AN ADU?
An ADU (Accessory Dwelling Unit) is a secondary housing unit on a residential property. It can be:
Detached. A separate structure from the main home, usually located in the backyard.
Attached. An addition to an existing home that shares a wall with the main home.
Interior Conversion. Transformed from an existing space like a basement.
Garage Conversion. Transformed from existing garage space.
Addition Over Garage. An addition to an existing garage that shares a wall with the garage.
Junior ADU (JADU). A smaller unit no greater than 500 sq ft that is converted space within the walls of an existing home.
CAN I BUILD MORE THAN ONE ADU?
Yes. Single-family lots may allow one ADU and one JADU. Multi-family lots may allow up to two detached ADUs.
CAN I BUILD AN ADU IN MY FRONT YARD?
Only if the backyard lacks sufficient space (minimum 800 sq ft with 4-ft setbacks).
DO I NEED TO LIVE ON THE PROPERTY?
No owner-occupancy requirement for ADUs, but JADUs do require it.
CAN I SELL MY ADU SEPARATELY?
In California, recent legislation (AB 1033) allows ADUs to be sold separately as condos under certain conditions.
ARE THERE PARKING REQUIREMENTS?
Often waived if the ADU is near public transit. Otherwise, local codes may apply.
ARE THERE SETBACK OR HEIGHT REQUIREMENTS?
Yes. Typically, 4-ft side and rear setbacks are required. Height limits vary by jurisdiction.
HOW BIG CAN MY ADU BE?
Attached: ≤50% of the main home or 1,200 sq ft (whichever is less).
Detached: ≤1,200 sq ft.
495
56 57City of Wildomar ADU Guidebook
CAN I CONVERT MY GARAGE OR SHED INTO AN ADU?
Yes, provided it meets building code standards for sanitation, egress, and safety.
CAN AN ADU BE TWO STORIES OR HAVE A BASEMENT?
Yes, depending on local zoning and building codes.
ARE PREFABRICATED ADUs CHEAPER?
Often yes, due to factory efficiencies, but site prep and installation costs still apply.
ARE PRE-APPROVED ADU PLANS CHEAPER?
Yes, due to the fact that there is no cost for creating plans.
WILL MY PROPERTY TAXES INCREASE?
Most likely. Only the new square footage is assessed. Existing untouched areas are not re-assessed.
WHAT DOES IT COST TO BUILD AN ADU?
Cost varies greatly depending on scope of work, existing site conditions, and whether financial benefits such as Pre-Approved Plans or electric service fee waiver are utilized. Costs can range from approximately $50,000 to over $300,000.
CAN I FINANCE AN ADU WITH A HOME EQUITY LOAN?
Yes. Other options include construction loans and government programs.
DO I NEED SEPARATE INSURANCE?
Yes, and tenants should carry renters insurance.
CAN I USE MY ADU AS A SHORT-TERM RENTAL?
No. Rentals must exceed 30 days.
CAN I USE MY ADU FOR FAMILY OR GUESTS?
Yes. ADUs are ideal for multi-generational living.
ARE ADUs GOOD FOR SENIORS?
Absolutely. They offer privacy, proximity to family, and aging-in-place opportunities.
City Contacts
Building + Safety
Department
[email protected]
CITY CONTACTS
City of Wildomar (951) 677-7751
M-F 7:30AM – 6:00PM
Public Works + Engineering
Services Department
developmentengineering
@wildomar.gov
Planning Department [email protected]
Munic
CITY OF
Pre-Ap
Webp
Parcel
STATE O
Califo
Housin
Comm
2025
AARP
Devel
Occup
Remov
ADU C
496
58 59City of Wildomar ADU Guidebook
References
LOCAL FUNDING
CalHFA https://www.calhfa.ca.gov/apps
/rates/
Habitat for Humanity
Riverside
https://www.habitatriverside.org/
Municipal Code https://ecode360.com/4412913
9 CITY OF WILDOMAR
Pre-Approved Plan
Webpage
https://www.wildomar.gov/439/
Pre-Approved-ADU-Program-PRA
DU
Parcel Information Tool https://wildomar.maps.arcgis.com /apps/webapp
viewer/index.html?id=e9ca066fe
bb2435bbbafa68a
5fe5ae1
STATE OF CALIFORNIA
California Department of
Housing and
CommunityDevelopment’s
2025 ADU Handbook
https://www.hcd.ca.gov/policy-a
nd-research/accessory-dwelling-u
nits
AARP Expanding ADU
Development and
Occupancy: Solutions for
Removing Local Barriers to
ADU Construction
https://www.aarp.org/livable-co
mmunities/housing/info-2021/ad
u-model-state-act-and-local-ordin
ance.html?msockid=25d21330bbf
1635f3be10543ba1d622f
California Tenants: A Guide
to Residential Tenants’ and
Landlords’ Rights and
Responsibilities
https://www4.courts.ca.gov/doc
uments/California-Tenants-Guide.
pdf
LOCAL FUNDING
CalHFA https://www.calhfa.ca.gov/apps
/rates/
Habitat for Humanity
Riverside
https://www.habitatriverside.org/
Municipal Code https://ecode360.com/4412913
9 CITY OF WILDOMAR
Pre-Approved Plan
Webpage
https://www.wildomar.gov/439/
Pre-Approved-ADU-Program-PRA
DU
Parcel Information Tool https://wildomar.maps.arcgis.com /apps/webapp
viewer/index.html?id=e9ca066fe
bb2435bbbafa68a
5fe5ae1
STATE OF CALIFORNIA
California Department of
Housing and
CommunityDevelopment’s
2025 ADU Handbook
https://www.hcd.ca.gov/policy-a
nd-research/accessory-dwelling-u
nits
AARP Expanding ADU
Development and
Occupancy: Solutions for
Removing Local Barriers to
ADU Construction
https://www.aarp.org/livable-co
mmunities/housing/info-2021/ad
u-model-state-act-and-local-ordin
ance.html?msockid=25d21330bbf
1635f3be10543ba1d622f
California Tenants: A Guide
to Residential Tenants’ and
Landlords’ Rights and
Responsibilities
https://www4.courts.ca.gov/doc
uments/California-Tenants-Guide.
pdf
Glossary
Accessory Dwelling Unit (ADU). The State of California’s Housing and Community Development Department defines an ADU as: “accessory to a primary residence and has complete independent living facilities for one or more persons. ADUs are either “detached from,” “attached to,” or located within the proposed or existing primary dwelling. This includes attached garages, storage areas or similar spaces, and accessory structures. The ADU can also be detached from the proposed or existing primary dwelling, including detached garages, provided it is located on the same lot” (HCD ADU Handbook: 21) Accessory Structure. A smaller subordinate structure to a primary structure.
A shed, deck, or ADU is an accessory structure on a residential property with a primary home.
Assessor Parcel Number (APN). A numerical ID assigned to each parcel in the City that is primarily used for property tax purposes.
Development Impact Fees. Fees that are collected prior to issuance of a building permit that pay for the impacts of the development. For example, a new home over 750 square feet will pay school impact fees, as the home will be part of the school district and any children living at the home will benefit from education services provided.
Dwelling Unit. A home where there are sleeping quarters, kitchen, bathroom, and other facilities and amenities. A dwelling unit can be an ADU, an apartment, townhome, single-family home, and others.
Easement. A legally binding restricted area on a property. Easements are typically present on residential properties along the side and rear yards for utilities, such as electricity and internet. These areas cannot have a structure placed in them, and in the event of utility servicing, any trees, shrubs, paving, structures, etc. will be removed as part of the servicing.
Infill Development. Development that occurs on properties that have existing utilities, such as water and electricity. The new development capitalizes on the existing infrastructure and is a better use than the existing site use.
Ingress and Egress. Ingress means site or building entry or access point, and egress means the site or building exit point.
Junior Accessory Dwelling Unit (JADU). The State of California’s Housing and Community Development Department defines a JADU as: “a […] unit that is no more than 500 square feet in size and contained entirely within a singlefamily residence. A JADU may include separate sanitation facilities or may share sanitation facilities with the existing structure” (HCD ADU Handbook: 9).
Primary Dwelling Unit. The dominant structure and/or use on site. A singlefamily home that is larger than a secondary home on the property is the primary dwelling unit, where the secondary unit is the accessory dwelling unit.
Setback. A distance from a property that delineates how close a structure can come to the property line. For example, a 5-foot setback means the structure can be no closer than 5 feet from that property line.
497
60 61City of Wildomar
ADU Guidebook
Topography. A way of measuring and depicting changes in land elevation.
A topography map is comprised of a series of lines drawn at regular intervals from one another, such as 5-foot intervals. The closer the lines the steeper the land slope, the further the flatter the land slope.
Zoning. A geographic area that sets the dwelling unit density, setback, height, and other development standards for the property within the defined area. *The above definitions are not legal definitions.
This section is written in partial fulfillment of the Southern California Association of Governments funding requirements.
PROJECT AREA BOUNDARY DEFINITION
The project area boundary is defined by the City boundary excluding zone districts that do not permit accessory dwelling units, or zones that do not permit the residential use. The excluded zone districts include Commercial General (C-G), Commercial Highway (C-H), Medical Center (M-C), Manufacturing/Industrial (M-I), Open Area Combining Zone (O-S), and Public Facilities (P-F). Significant portions of the City’s low density residential zone districts do not meet the REAP 1.0 definition of infill—Residential Mountainous (R-M), Residential Agriculture (R-A), Residential Rural (R-R), Residential Low (R-1), and Mobilehome Subdivisions and Mobilehome Park (R-T)—yet these zone districts are included within the project boundary for compliance with State law. Government Code Section 66310 requires local jurisdictions to permit accessory dwelling units in all zone districts permitting single-family and multifamily uses.
Additionally, portions of the Residential Mountainous (R-M) Zone District to the southernmost area of the City are located within United States Forest Service and California State Lands Commission protected lands; these areas have been excluded from the project area boundary, as private residential development is not permitted in on these protected lands.
MAJOR ROADS
The project area is divided by Interstate 15 (also known as Temecula Valley Freeway) that runs a central course through the City, or from the northwest portion of the City to the southeast.
Other major roads include Clinton Keith Road running a general east-west orientation, Bundy Canyon Road also running a general east-west orientation, Grand Avenue running northwest to southwest, Palomar Street also running northwest to southwest, Mission Trail running north to south in the north half of the City and terminating at Palomar Street, and Corydon Road running southwest to northeast.
MAJOR LANDMARKS
Major landmarks in the City include the Santa Ana and Santa Rosa Mountain Foothills to the south, Memorial Hill and open space to the north, Southwest Healthcare Inland Valley Hospital that sits at the southern portion of the City adjacent to Interstate 15 demarcating the gateway into the City from the south, and Elsinore High School to the northern portion of the City adjacent to Bundy Canyon Road.
AGRICULTURAL, NATURAL AND WORKING LANDS
There are no agricultural or working lands identified in the City. Portions of the Residential Mountainous (R-M) Zone District to the southernmost area of the City is located within United States Forest Service and California State Lands Commission protected lands. These areas have been excluded from the project area boundary, as private residential development is not permitted in conservation areas.
URBAN FEATURES
The major destinations in the City include the Southwest Healthcare Inland Valley Hospital, Elsinore High School, as well as the variety of commercial retail uses along the Interstate 15 corridor that provide restaurants, grocery, home repair, medical services, fitness, and a variety of other retail uses and services. The City of Wildomar is served by Riverside Transit Authority’s route 8 and 23. Route 8 connects Wildomar and the City of Lake Elsinore via Wildomar Trail and Palomar Street. Route 23 connects Wildomar to Murrieta via Palomar Street and Wildomar Trail. The City is majority developed albeit with undeveloped fringes to the southwest and northeast edges of the City. Large areas in the Santa Ana and Santa Rosa Mountain Foothills have limited or no infrastructure or building development. Additionally, hillside areas to the northeast of the City include a mix of locally protected open space and low density residential, much of the low density residential has limited or no infrastructure and development. The majority of the City’s commercial development is concentrated along the Interstate 15 corridor and the arterial roads intersecting it. These intersections with the Interstate 15 corridor are the City’s urban centers. The City’s parks include the Marna O’Brien Park, Malaga Park, Windsong Park, and Regency Heritage Park.
498
62 Source: Google Earth
499
Ciudad de Wildomar
Planifica y construye tu ADU con confianza usando
consejos de expertos, pasos claros y listas de verificación útiles, todo en una guía completa y fácil de usar
Este proyecto está financiado por la Asociación de Gobiernos del Sur de California (SCAG) por a través del programa REAP 2.0. “Regional Early Action Program 2021” con fondos del Estado de California
2026
500
Agradecimientos +
Colaboradores
CONSEJO MUNICIPAL
Carlos Marquez, Alcaldesa y Miembro del Consejo del Distrito 1 Dustin Nigg, Alcaldesa Pro Tem & Miembro del Consejo del Distrito 2 Ashlee DePhillippo, Miembro del Consejo del Distrito 5
Joseph Morabito, Miembro del Consejo del Distrito 3
Bridgette Moore, Miembro del Consejo del Distrito 4
COMISIÓN DE PLANIFICACIÓN
Nolan King, Presidente
Dr. Charles Golden III, Vicepresidente
Eric Filar, Comisionado
John Hume, Comisionado
Rene Cambero, Comisionado
ADMINISTRACIÓN MUNICIPAL
Chris Mann, Administrador de la Cuidad
EQUIPO MUNICIPAL
Robert Flores, Director de Desarrollo Comunitario
Scott Burns, Director de Construcción
Abdu Lachgar, Planificador Principal
Joelle Perales, Pasante de Planificación
CONSULTOR | MICHAEL BAKER INTERNATIONAL
Ashley Spinrad, Arquitecta
Edward Hanbicki, Arquitecto de Registro
Olga Zaremba, Diseñador Arquitectónico Senior
Alicia Gonzalez, Gerente de Planificación
Carolyn Fahey, Planificadora Principal
FINANCIAMIENTO + APOYO
¿POR QUÉ USAR ESTA GUÍA?
Esta guía está diseñada para ayudar a solicitantes nuevos a que entiendan el proceso para obtener un permiso de construcción en la Ciudad de Wildomar (Ciudad) para una unidad de vivienda accesoria (ADU) o una unidad de vivienda accesoria junior (JADU). Identifica referencias clave, describe los pasos del proceso y señala errores comunes para ayudar a solicitantes preparar eficazmente.
Nota: cuando se habla de ADU de manera general, también se incluyen las JADU.
CÓMO NAVEGAR ESTA GUÍA
En esta guía se incluyen anotaciones que destacan información clave. El material se organiza según la secuencia del proceso de revisión del permiso de construcción; conviene leer el documento completo antes de iniciar la solicitud.
Se incluyen técnicas para preparar una solicitud de permiso de construcción, que incluyen listas de verificación detalladas, así como resúmenes de procesos para ayudar a establecer expectativas y permitir planificación anticipada.
Usando esta Guía
¡Enlaces útiles y datos interesantes
aquí!
Busque los cuadros azules para información útil.
501
¿Qué es una ADU?
Beneficios de las ADU
Cómo Empezar
¿Cuánto Cuesta una ADU?
Obtener un Permiso de Construcción
Programa de ADU Preaprobadas
Preguntas Frecuentes
Contactos de la Ciudad
Referencias
Glosario
Contenido
79 11
17 22
27 55
57 58
59 Source: Google Earth
502
7City of Wildomar
ADU Guidebook
En general, una unidad de vivienda accesoria es una vivienda pequeña tipo apartamento que comparte una propiedad con una vivienda principal más grande, normalmente una casa unifamiliar. Las ADU pueden variar en tipo, tamaño, configuración y ubicación. Muchos de estos factores están definidos por ley estatal.
UNIDAD DE VIVIENDA ACCESORIA (ADU). Una ADU es una vivienda más pequeña en relación con la vivienda principal de una propiedad, o una residencia accesoria a la vivienda principal. La ADU debe tener instalaciones completamente independientes para una o más personas. Puede estar “separada”, “adjunta” o dentro de la vivienda principal propuesta o existente.
Esto incluyendo garajes adjuntos o espacios similares y estructuras accesorias; La ADU también pude ser separada de la vivienda principal propuesta o existente, incluyendo garajes separados, mientras estén dentro del mismo lote.
UNIDAD DE VIVIENDA ACCESORIA JUNIOR (JADU). Una JADU
es una unidad de no más de 500 pies cuadrados en tamaño y contenida completamente dentro de una vivienda unifamiliar. Puede incluir instalaciones sanitarias propias o compartirlas con la estructura existente. ¿Qué es una ADU?
Source: Google Earth
Separada. Estructura independiente en
una propiedad residencial existente con
vivienda principal
503
8 9City of Wildomar
ADU Guidebook
Adición sobre garaje. adición al
garaje existente.
Beneficios de las ADU
BENEFICIOS PRIVADOS
•Las ADU pueden proporcionar una fuente de ingresos para los propietarios de viviendas.
•Las ADU permiten que las familias extendidas estén cerca unas de otras y al mismo tiempo mantengan la privacidad.
•Las ADU brindan a los propietarios la flexibilidad para compartir áreas de vivienda independientes, facilitando el envejecimiento de adultos mayores en casa y cierta independencia para jóvenes. 1 Departamento de Vivienda y Desarrollo Comunitario de California, Manual de Unidades de Vivienda Accesorias: enero de 2025, 9 de septiembre de 2025, p. 4.
Las ADU son un tipo de vivienda asequible que permite mayores opciones y oportunidades de viviendas. Por sus costos asequibles combinada con la relativa facilidad con la que se puede agregar a una propiedad residencial existente, lo convierten en un contribuyente significativo para abordar la escasez de oferta de viviendas en todo el estado. Según el Departamento de Vivienda y Desarrollo Comunitario de California, en los últimos diez años, el número de ADU en California se ha multiplicado por 20 y el 21% de las viviendas permitidas en 2023 fueron tipo ADU1. La imagen a continuación muestra cómo se puede desarrollar fácilmente un vecindario tradicional con significativamente más unidades de vivienda agregando unidades adicionales de vivienda (ADU).
BENEFICIOS COMUNITARIOS
•Las ADU son un tipo de vivienda flexible que puede ser ideal para personas, parejas, familias pequeñas, amigos, jóvenes y adultos mayores por igual.
•Las ADU pueden ofrecer tanto espacio como muchos
apartamentos y condominios nuevos, con amplio espacio abierto privado.
•Las ADU son más económicas de construir en California porque la propiedad ya cuenta con servicios de utilidad (electricidad, agua, alcantarillado, etc.).
•Las ADU frecuentemente son construidas con estructura de madera, que es significativamente menos costosa que una casa en un edificio multifamiliar nuevo. Conversión interior. conversión de espacio dentro de la vivienda existente.
Adjunta. adición a la
vivienda principal.
Conversión de garaje.
conversión del garaje existente.
504
10 11City of Wildomar
ADU Guidebook
Cómo Empezar
¿PUEDO CONSTRUIR UNA ADU EN MI PROPIEDAD?
Depende. Lo primero que debe verificar al considerar construir una ADU en su propiedad es en qué distrito de zonificación se encuentra. Para encontrar el distrito de zonificación de su propiedad, acceda el sito de Información de Parcelas, disponible en el sitio web de la Ciudad. Escriba la dirección de su propiedad o el Número de Parcela del Tasador (APN) en la barra de búsqueda para localizar su propiedad. Luego, revise los resultados de la búsqueda para el distrito de zonificación de su propiedad. En general, las ADU solo se permiten en distritos con zonificación residencial, que se indican con una “R” (por ejemplo, RM o R1). Para obtener una lista completa de los distritos con zonificación residencial de la Ciudad, consulte la Tabla
17.25.020-1 del Código de Desarrollo de Wildomar.
ESTÁNDARES DE DESARROLLO
Una vez que haya determinado si se permite una ADU en su propiedad, deberá verificar si cumple con todos los estándares y requisitos para una ADU en su propiedad. El estado ha facilitado el cumplimiento de estos estándares y requisitos para los propietarios, pero hay una serie de detalles a tener en cuenta, que se detallan en la tabla a continuación. Asegúrese de confirmar los requisitos con el Departamento de Planificación.
Encuentra tu zonificación:
Usa el sitio de Información de Parcelas para encontrar el distrito de zonificación de su propiedad
Encuentra los estándares de tu
zonificación:
Utilice el Código Municipal de la Ciudad para encontrar los estándares de desarrollo para la zonificación de su propiedad, así como otra información clave
Para asistencia con la planificación y
permisos:
Comuníquese con un planificador al (951) 677-7751 o visite el Departamento de Planificación
Adjunta. adición a
la vivienda principal.
Conversión de garaje.
conversión del garaje existente.
Adición sobre garaje.
adición al garaje
existente.
Conversión interior. conversión de
espacio dentro de la vivienda existente
Separada. estructura separada de la
vivienda existente.
505
12 13City of Wildomar ADU Guidebook
Estándares de Desarrollo Estándares de Desarrollo
Viviendas unifamiliares. Viviendas de
baja densidad, generalmente compuestas
por viviendas unifamiliares con parcelas
separadas
Viviendas multifamiliares. Viviendas de
baja densidad, generalmente compuestas
por viviendas unifamiliares con parcelas
separadas
Viviendas multifamiliares. Viviendas
de densidad media, generalmente casas
adosadas con garajes separados o
adjuntos
Límite de lote o límite de propiedad. Define el alcance de una propiedad. Normalmente, este límite se encuentra más atrás que el borde de la
banqueta o calle frente a la casa
Servidumbre de servicios
públicos. Normalmente, un área de 5
a7 pies de ancho adyacente al límite
de la propiedad donde no se pueden
construir estructuras
Área edificable de la estructura
principal. Esta es el área donde
se puede ubicar una estructura
principal. Esta área se determina
según las distancias mínimas y
las servidumbres de servicios de
utilidad.
Área edificable de estructura
auxiliar. Esta es el área donde
se puede ubicar una nueva ADU
separada. Esta área se determina
según las distancias mínimas y las
servidumbres de servicios de utilidad.
ADUs dentro el retranqueo del
patio delantero.
permitido solo si la ADU es de 800
pies cuadrados o menos y no cabe en
otro lugar en la propiedad
TAMAÑO DE UNIDAD
Separada
Adjunta 50% del tamaño de la vivienda
principal o un máximo de 1,200
pies cuadrados, lo que sea menor
Hasta 1,200 pies cuadrados
ALTURA DE ESTRUCTURA
16 pies estándar
8–20 pies cerca de tránsito
25 pies máximo
Todos ADU
ADU o JADU dentro de una
estructura existente
No se requieren para
conversiones dentro del área
habitable existente ni en estructuras
auxiliares existentes
DISTANCIAS MINIMAS + SEPARACIÓN
ADU adjunta o separada
nueva
Máximo 4 pies desde linderos
laterales y traseros de la
propiedad
ADU reemplazando la
estructura existente
No se requieren distancias
mínimas si se construye en la
misma ubicación y con las mismas
dimensiones
Retranqueo del patio
delantero
Permitido en el retranqueo del
patio delantero, pero solo si la
ADU es de 800 pies cuadrados o
menos y no cabe en otro lugar en
la propiedad
DISEÑO
Estándares objetivos aplican a
todas las ADU
Todos ADU
Conversión de garaje No se requiere estacionamiento
de reemplazo
ESTACIONAMIENTO
ADU Estándar máximo 1 espacio por unidad o
dormitorio (lo que sea menor);
puede ser en tándem o dentro de
los retranqueos, a menos que no
sea viable debido a la topografía
o a la seguridad contra incendios
o de vida
Unidades de eficiencia y
Estudios
JADUs No se requiere estacionamiento
No se requiere estacionamiento
adicional
Todos ADU No se requiere estacionamiento
de reemplazo si se convierte el
garaje o la cochera
DENSIDAD DE UNIDADES
1 ADU + 1 JADU por
propiedad
Propiedad unifamiliar
hasta 8 ADU separadas +
conversiones interiores de hasta
25% de las unidades existentes
Desarrollo multifamiliar
ZONAS
Todos ADU Solo en distritos residencial
ROCIADORES
Si la vivienda existente tiene
rociadores, la ADU también los
requiere
Varía
BAÑOS
ADU baño completo
JADU puede ser compartido con la
residencia principal
SERVICIOS DE UTILIDAD
No se requerirán nuevas
conexiones de agua,
alcantarillado, electricidad ni
gas para las conversiones
Todos Proyectos
COCINAS
ADU cocina completa
JADU cocina eficiente
2 1 En algunos casos pueden lograrse tres J/ADU.
2 Se pueden agregar hasta 8 ADU a una propiedad multifamiliar, siempre que la cantidad de ADU no exceda la cantidad de unidades de vivienda existentes en la propiedad.
3 No se puede impedir una ADU menos de 800 pies
cuadrados incluso si la ADU estuviera dentro del retroceso frontal
Separada
Adjunta 50% del tamaño de la vivienda
principal o un máximo de 1,200
pies cuadrados, lo que sea menor
Hasta 1,200 pies cuadrados
ADU o JADU dentro de una
estructura existente
No se requieren para
conversiones dentro del área
habitable existente ni en estructuras
auxiliares existentes
DISTANCIAS MINIMAS + SEPARACIÓN
ADU adjunta o separada
nueva
Máximo 4 pies desde linderos
laterales y traseros de la
propiedad
ADU reemplazando la
estructura existente
No se requieren distancias
mínimas si se construye en la
misma ubicación y con las mismas
dimensiones
Retranqueo del patio
delantero
Permitido en el retranqueo del
patio delantero, pero solo si la
ADU es de 800 pies cuadrados o
menos y no cabe en otro lugar en
la propiedad
Distancia entre estructuras 7 o 10 pies (según distrito de zonificación), donde sea factible
DISEÑO
Estándares objetivos aplican a
todas las ADU
Todos ADU
Conversión de garaje No se requiere estacionamiento
de reemplazo
Unidades de eficiencia y
Estudios
JADUs No se requiere estacionamiento
No se requiere estacionamiento
adicional
de reemplazo si se convierte el
garaje o la cochera
SERVICIOS
Todos Proye
3 1
habitable existente ni en estructuras
auxiliares existentes
ADU reemplazando la
estructura existente
No se requieren distancias
mínimas si se construye en la
misma ubicación y con las mismas
dimensiones
Retranqueo del patio
delantero
Permitido en el retranqueo del
patio delantero, pero solo si la
ADU es de 800 pies cuadrados o
menos y no cabe en otro lugar en
la propiedad
Distancia entre estructuras 7 o 10 pies (según distrito de zonificación), donde sea factible
Todos ADU
506
14 15City of Wildomar ADU Guidebook
Estándares de Desarrollo
TAMAÑO DE UNIDAD
Separada
Adjunta 50% del tamaño de la vivienda
principal o un máximo de 1,200
pies cuadrados, lo que sea menor
Hasta 1,200 pies cuadrados
ALTURA DE ESTRUCTURA
16 pies estándar
8–20 pies cerca de tránsito
25 pies máximo
Todos ADU
ADU o JADU dentro de una
estructura existente
No se requieren para
conversiones dentro del área
habitable existente ni en estructuras
auxiliares existentes
DISTANCIAS MINIMAS + SEPARACIÓN
ADU adjunta o separada
nueva
Máximo 4 pies desde linderos
laterales y traseros de la
propiedad
ADU reemplazando la
estructura existente
No se requieren distancias
mínimas si se construye en la
misma ubicación y con las mismas
dimensiones
Retranqueo del patio
delantero
Permitido en el retranqueo del
patio delantero, pero solo si la
ADU es de 800 pies cuadrados o
menos y no cabe en otro lugar en
la propiedad
DISEÑO
Estándares objetivos aplican a
todas las ADU
Todos ADU
Conversión de garaje No se requiere estacionamiento
de reemplazo
ESTACIONAMIENTO
ADU Estándar máximo 1 espacio por unidad o
dormitorio (lo que sea menor);
puede ser en tándem o dentro de
los retranqueos, a menos que no
sea viable debido a la topografía
o a la seguridad contra incendios
o de vida
Unidades de eficiencia y
Estudios
JADUs No se requiere estacionamiento
No se requiere estacionamiento
adicional
Todos ADU No se requiere estacionamiento
de reemplazo si se convierte el
garaje o la cochera
DENSIDAD DE UNIDADES
1 ADU + 1 JADU por
propiedad
Propiedad unifamiliar
hasta 8 ADU separadas +
conversiones interiores de hasta
25% de las unidades existentes
Desarrollo multifamiliar
ZONAS
Todos ADU Solo en distritos residencial
ROCIADORES
Si la vivienda existente tiene
rociadores, la ADU también los
requiere
Varía
BAÑOS
ADU baño completo
JADU puede ser compartido con la
residencia principal
SERVICIOS DE UTILIDAD
No se requerirán nuevas
conexiones de agua,
alcantarillado, electricidad ni
gas para las conversiones
Todos Proyectos
COCINAS
ADU cocina completa
JADU cocina eficiente
Estándares de Desarrollo
TAMAÑO DE UNIDAD
Separada
Adjunta 50% del tamaño de la vivienda
principal o un máximo de 1,200
pies cuadrados, lo que sea menor
Hasta 1,200 pies cuadrados
ADU o JADU dentro de una
estructura existente
No se requieren para
conversiones dentro del área
habitable existente ni en estructuras
auxiliares existentes
DISTANCIAS MINIMAS + SEPARACIÓN
ADU adjunta o separada
nueva
Máximo 4 pies desde linderos
laterales y traseros de la
propiedad
ADU reemplazando la
estructura existente
No se requieren distancias
mínimas si se construye en la
misma ubicación y con las mismas
dimensiones
Retranqueo del patio
delantero
Permitido en el retranqueo del
patio delantero, pero solo si la
ADU es de 800 pies cuadrados o
menos y no cabe en otro lugar en
la propiedad
Distancia entre estructuras 7 o 10 pies (según distrito de zonificación), donde sea factible
DISEÑO
Estándares objetivos aplican a
todas las ADU
Todos ADU
Conversión de garaje No se requiere estacionamiento
de reemplazo
ESTACIONAMIENTO
ADU Estándar máximo 1 espacio por unidad o
dormitorio (lo que sea menor);
puede ser en tándem o dentro de
los retranqueos, a menos que no
sea viable debido a la topografía
o a la seguridad contra incendios
o de vida
Unidades de eficiencia y
Estudios
JADUs No se requiere estacionamiento
No se requiere estacionamiento
adicional
Todos ADU No se requiere estacionamiento
de reemplazo si se convierte el
garaje o la cochera
1 ADU + 1 JADU por
propiedad
Propiedad unifamiliar
hasta 8 ADU separadas +
conversiones interiores de hasta
25% de las unidades existentes
Desarrollo multifamiliar
ROCIADORES
Si la vivienda existente tiene
rociadores, la ADU también los
requiere
Varía
BAÑOS
ADU baño completo
JADU puede ser compartido con la
residencia principal
SERVICIOS DE UTILIDAD
No se requerirán nuevas
conexiones de agua,
alcantarillado, electricidad ni
gas para las conversiones
Todos Proyectos
Altura De Estructura. La mayoría de
las ADU no deben tener más de 16
pies de altura total
Estacionamiento. En la mayoría
de los casos, se puede proporcionar
un espacio de estacionamiento
descubierto en la entrada
Cocina completa típica. Tiene
fregadero, estufa y horno, lavaplatos y
refrigerador
Baño. Un baño debe tener inodoro y
ducha o una combinación de ducha y
bañera
Cocina eficiente típica. Fregadero,
estufa y refrigerador pequeño.
ALTURA DE ESTRUCTURA
16 pies estándar
8–20 pies cerca de tránsito
25 pies máximo
Todos ADU
DISEÑO
Estándares objetivos aplican a
todas las ADU
Todos ADU
Conversión de garaje No se requiere estacionamiento
de reemplazo
ESTACIONAMIENTO
ADU Estándar máximo 1 espacio por unidad o
dormitorio (lo que sea menor);
puede ser en tándem o dentro de
los retranqueos, a menos que no
sea viable debido a la topografía
o a la seguridad contra incendios
o de vida
Unidades de eficiencia y
Estudios
JADUs No se requiere estacionamiento
No se requiere estacionamiento
adicional
Todos ADU No se requiere estacionamiento
de reemplazo si se convierte el
garaje o la cochera
ROCIADORES
Si la vivienda existente tiene
rociadores, la ADU también los
requiere
Varía
BAÑOS
ADU baño completo
JADU puede ser compartido con la
residencia principal
SERVICIOS DE UTILIDAD
No se requerirán nuevas
conexiones de agua,
alcantarillado, electricidad ni
gas para las conversiones
Todos Proyectos
COCINAS
ADU cocina completa
JADU cocina eficiente
5 4 A menos de 0.5 millas del transporte público; En un distrito histórico; Parte de la residencia principal existente o propuesta o estructura auxiliar; Cuando se requieren permisos de estacionamiento en la calle, pero no se ofrecen al ocupante de la ADU; Cuando un vehículo de uso compartido se encuentra a menos de una cuadra; Cuando se presenta con un permiso para una nueva vivienda unifamiliar o multifamiliar
5 Las agencias locales pueden imponer estándares objetivos, pero no si restringen irrazonablemente la creación de ADU
4 507
16 17City of Wildomar ADU Guidebook
¿Debería contratar a un profesional?
El desarrollo puede ser una tarea abrumadora, y muchas personas optan por contratar profesionales para que les ayuden a crear una solicitud de ADU y navegar el proceso de permisos. Trabajar con un contratista, arquitecto, ingeniero, arquitecto de paisaje o topógrafo licenciado puede brindar una guía invaluable en las distintas etapas del proceso de diseño y construcción.
Estos profesionales licenciados ofrecen diferentes servicios que pueden ayudarle con su proyecto.
Un contratista es una excelente opción para construir su unidad.
Frecuentemente, un contratista trabaja en una empresa de diseño y construcción que ofrece servicios de diseño, ingeniería, paisajismo y topografía en un solo lugar. El contratista debe tener licencia del Estado de California.
Un arquitecto ofrece servicios generales de diseño, planificación de pisos y construcción.
Un diseñador ofrece servicios de diseño, pisos y, en ocasiones, diseño de paisajes, pero no es un profesional con licencia.
Un ingeniero ofrece cálculos estructurales, diseño de servicios públicos, drenaje del sitio y otros servicios según la necesidad y su área de especialidad.
Un arquitecto de paisaje ofrece planificación de riego, diseño de jardines, selección de plantas y cuidado de árboles existentes.
Un topógrafo ofrece servicios para localizar el límite de su propiedad, lo cual es esencial para garantizar que la construcción no se realice en servidumbres dentro de su propiedad o fuera de su límite de propiedad.
Es muy recomendable que los profesionales que contrate para su ADU tengan licencia y que se verifiquen sus referencias antes de firmar cualquier contrato.
A pesar de su pequeño tamaño, las ADU son inversiones significativas. Es necesario una planificación presupuestaria inicial para garantizar un proyecto exitoso. La siguiente estimación de costos y tarifas brindan una idea sobre qué costos considerar para su proyecto de ADU, además de los costos de mano de obra y materiales para la construcción.
ESTIMANDO EL COSTO PARA CREAR UNA SOLICITUD DE PERMISO
Uno de los costos más significativos, aparte de la construcción, son los planos o dibujos que muestren el aspecto de su ADU, su ubicación y cómo se construirá.
Contratar a un arquitecto puede costar entre $3,000 y $10,000 para crear los planos, realizar las revisiones necesarias y ayudar con el proceso de permisos. Alternativamente, los Planos Preaprobados están disponibles de la ciudad sin costo (consulte la sección Planos Preaprobados a continuación).
TARIFAS DE PERMISO
Las tarifas de los permisos cubren el costo del tiempo que el personal municipal dedica a revisar los planos presentados. Las tarifas se cobran al momento de la presentación del permiso de construcción, al presentar las revisiones, al emitir el permiso de construcción final y al emitir el certificado de ocupación.
Consulte con el personal municipal sobre el cálculo del costo total de la revisión y en qué puntos del proceso de revisión se deben pagar las tarifas. ¿Cuánto Cuesta una ADU?
Source: City of Bakersfield
508
18 19City of Wildomar ADU Guidebook
Costos y Tarifas Estimados
TARIFAS DE IMPACTO DE DESARROLLO
Las tarifas de impacto del desarrollo cubren los costos de la nueva vivienda para fondos de capital para carreteras, escuelas, servicios públicos, servicios de emergencia y otros servicios públicos. Solo las unidades de 750 pies cuadrados o más deben pagar las tarifas de impacto del desarrollo al momento de la emisión del permiso de construcción..
TARFIAS DE INSPECCION
Inspection fees cover the cost of staff time to travel to the project site, inspect the installation, and review the plans submitted. Fees are collected at the time when the final building permit is issued, and when the certificate of occupancy is issued. Consult with City staff on estimating total fees and at which points of the construction process fees are due.
TARIFAS DE CONEXIÓN
Al igual que las tarifas de impacto, los proveedores de servicios públicos cobran una tarifa de conexión para compensar los costos de brindar nuevos servicios a una propiedad. Para determinar el costo de la tarifa de conexión, comuníquese con las siguientes entidades:
FUENTES DE FINANCIACIÓN
Existen diversas fuentes de financiamiento para ayudar a agregar ADUs a propiedades existentes, especialmente en casos en que la unidad se utilizará para hogares de bajos ingresos o si el propietario actual se considera de bajos ingresos. Dos fuentes de financiamiento clave disponibles para propietarios elegibles son el Programa de Subvenciones para ADU de la Agencia de Financiamiento de Viviendas de California (CalHFA), que proporciona fondos directos a los propietarios que califican, y el Programa CalHome, que otorga subvenciones a jurisdicciones locales y organizaciones sin fines de lucro como Habitat for Humanity para la construcción de ADUs.
Posibles fuentes de financiación de
ADU:
CalHFA | Agencia de Financiamiento de Viviendas de
California al (877) 9CALHFA o visita el sitio CalHFA
Habitat for Humanity | Llame al 951-787-6764, envíe un
correo electrónico a [email protected] o visita el sitio Riverside Habitat for Humanity
hasta $31,479 Tarifa de Impacto Urbano - para
unidades de 750 pies cuadrados
o mas
TARIFAS DE IMPACTO DE DESARROLLO
$0 Tarifa de Impacto Urbano - para
unidades de 749 pies cuadrados
o menos
$0 Tarifa de Impacto Escolar - para
unidades de 500 pies cuadrados
o menos
$6,204 Tarifa de Impacto Escolar - para
unidades de 501 pies cuadrados
o mas
TARIFAS DE LA SOLICITUD DE PERMISO
$0 Tarifa de Planificación
hasta $5,759.57 Tarifa de construcción
COSTOS DE LOS PLANOS
Planos personalizados creados
por un arquitecto
$15,000
Planos Preaprobados
disponibles en el sitio web de la
ciudad
$0
$796 Riverside County Department of
Environmental Health - solo si se
propone un pozo o un tanque
séptico
TARIFAS DE CONEXIÓN
$170 Elsinore Valley Municial Water
District - para agua y
alcantarillado, a menos que se
utilice una fuente de agua privada
$(5,700) Southern California Edison – Los
costos varían entre $3,000 y
$30,000, según el proyecto. Los
proyectos que expanden el
servicio existente cuestan
aproximadamente entre $3,000 y
$5,000. Si la ADU propone tener
totalmente energía eléctrica, se
pueden acreditar hasta $5,700
para la tarifa de conexión del
servicio
Por favor póngase en
contacto con Riverside
County Department of
Environmental Health
Riverside County Department of
Environmental Health - Varía.
Por favor, contáctenos para
verificar si su lote cumple con los
requisitos para un sistema séptico
Por favor póngase en
contacto con SoCal Gas
SoCal Gas - Si se utilizará gas
TARFIAS DE INSPECCION
Mecánica, Eléctrica, Plomería,
Estructural
hasta $2,327.70
GASTOS TOTALES
Si la ADU tiene menos de 499
pies cuadrados, utiliza los
Planos Preaprobados,
expanden el servicio de agua,
alcantarillado y electricidad
existente, y utiliza solo
electricidad en la ADU
$4,748.13
Si la ADU tiene 500 pies
cuadrados o mas, utiliza los
Planos Preaprobados,
expanden el servicio de agua,
alcantarillado y electricidad
existente, y utiliza solo
electricidad en la ADU
$14,461.27
El presupuesto de ejemplo ayuda a crear una estimación aproximada de las tarifas enumeradas anteriormente, vigentes a noviembre de 2025. Consulte con la ciudad y los proveedores de servicios para obtener una estimación actualizada de las tarifas aplicables.
hasta $31,479 Tarifa de Impacto Urbano - para
unidades de 750 pies cuadrados
o mas
TARIFAS DE IMPACTO DE DESARROLLO
$0 Tarifa de Impacto Urbano - para
unidades de 749 pies cuadrados
o menos
$0 Tarifa de Impacto Escolar - para
unidades de 500 pies cuadrados
o menos
$6,204 Tarifa de Impacto Escolar - para
unidades de 501 pies cuadrados
o mas
TARIFAS DE LA SOLICITUD DE PERMISO
$0 Tarifa de Planificación
hasta $5,759.57 Tarifa de construcción
COSTOS DE LOS PLANOS
Planos personalizados creados
por un arquitecto
$15,000
Planos Preaprobados
disponibles en el sitio web de la
ciudad
$0
$796 Riverside County Department of
Environmental Health - solo si se
propone un pozo o un tanque
séptico
TARIFAS DE CONEXIÓN
$170 Elsinore Valley Municial Water
District - para agua y
alcantarillado, a menos que se
utilice una fuente de agua privada
$(5,700) Southern California Edison – Los
costos varían entre $3,000 y
$30,000, según el proyecto. Los
proyectos que expanden el
servicio existente cuestan
aproximadamente entre $3,000 y
$5,000. Si la ADU propone tener
totalmente energía eléctrica, se
pueden acreditar hasta $5,700
para la tarifa de conexión del
servicio
Por favor póngase en
contacto con Riverside
County Department of
Environmental Health
Riverside County Department of
Environmental Health - Varía.
Por favor, contáctenos para
verificar si su lote cumple con los
requisitos para un sistema séptico
Por favor póngase en
contacto con SoCal Gas
SoCal Gas - Si se utilizará gas
TARFIAS DE INSPECCION
Mecánica, Eléctrica, Plomería,
Estructural
hasta $2,327.70
GASTOS TOTALES
Si la ADU tiene menos de 499
pies cuadrados, utiliza los
Planos Preaprobados,
expanden el servicio de agua,
alcantarillado y electricidad
existente, y utiliza solo
electricidad en la ADU
$4,748.13
Si la ADU tiene 500 pies
cuadrados o mas, utiliza los
Planos Preaprobados,
expanden el servicio de agua,
alcantarillado y electricidad
existente, y utiliza solo
electricidad en la ADU
$14,461.27
El presupuesto de ejemplo ayuda a crear una estimación aproximada de las tarifas enumeradas anteriormente, vigentes a noviembre de 2025. Consulte con la ciudad y los proveedores de servicios para obtener una estimación actualizada de las tarifas aplicables.
hasta $31,479 Tarifa de Impacto Urbano - para
unidades de 750 pies cuadrados
o mas
TARIFAS DE IMPACTO DE DESARROLLO
$0 Tarifa de Impacto Urbano - para
unidades de 749 pies cuadrados
o menos
$0 Tarifa de Impacto Escolar - para
unidades de 500 pies cuadrados
o menos
$6,204 Tarifa de Impacto Escolar - para
unidades de 501 pies cuadrados
o mas
TARIFAS DE LA SOLICITUD DE PERMISO
$0 Tarifa de Planificación
hasta $5,759.57 Tarifa de construcción
COSTOS DE LOS PLANOS
Planos personalizados creados
por un arquitecto
$15,000
Planos Preaprobados
disponibles en el sitio web de la
ciudad
$0
$796 Riverside County Department of
Environmental Health - solo si se
propone un pozo o un tanque
séptico
TARIFAS DE CONEXIÓN
$170 Elsinore Valley Municial Water
District - para agua y
alcantarillado, a menos que se
utilice una fuente de agua privada
$(5,700) Southern California Edison – Los
costos varían entre $3,000 y
$30,000, según el proyecto. Los
proyectos que expanden el
servicio existente cuestan
aproximadamente entre $3,000 y
$5,000. Si la ADU propone tener
totalmente energía eléctrica, se
pueden acreditar hasta $5,700
para la tarifa de conexión del
servicio
Por favor póngase en
contacto con Riverside
County Department of
Environmental Health
Riverside County Department of
Environmental Health - Varía.
Por favor, contáctenos para
verificar si su lote cumple con los
requisitos para un sistema séptico
Por favor póngase en
contacto con SoCal Gas
SoCal Gas - Si se utilizará gas
TARFIAS DE INSPECCION
Mecánica, Eléctrica, Plomería,
Estructural
hasta $2,327.70
GASTOS TOTALES
Si la ADU tiene menos de 499
pies cuadrados, utiliza los
Planos Preaprobados,
expanden el servicio de agua,
alcantarillado y electricidad
existente, y utiliza solo
electricidad en la ADU
$4,748.13
Si la ADU tiene 500 pies
cuadrados o mas, utiliza los
Planos Preaprobados,
expanden el servicio de agua,
alcantarillado y electricidad
existente, y utiliza solo
electricidad en la ADU
$14,461.27
El presupuesto de ejemplo ayuda a crear una estimación aproximada de las tarifas enumeradas anteriormente, vigentes a noviembre de 2025. Consulte con la ciudad y los proveedores de servicios para obtener una estimación actualizada de las tarifas aplicables.
509
20 21City of Wildomar
ADU Guidebook
ALQUILAR TU ADU
Asegúrese de obtener una estimación precisa de los ingresos potenciales por alquiler su ADU y considere los impuestos sobre los ingresos por alquiler.
Trabajar con un agente inmobiliario de confianza le proporcionará una estimación precisa de los ingresos potenciales por alquiler de su nueva ADU.
Mientras puede consultar las tarifas de alquiler de unidades similares en su zona en Zillow, Redfin y otras plataformas, se recomienda que un agente inmobiliario le proporcione información sobre estas estimaciones. Los agentes inmobiliarios también pueden ayudarle a alquilar la unidad mientras está en construcción para garantizar que se alquile tan pronto como esté habitable. El impuesto sobre la renta sobre los pagos de alquiler oscila entre el 10% y el 37% del monto de los ingresos, dependiendo de los ingresos totales y el estado civil del propietario. Un especialista en impuestos puede proporcionarle una estimación precisa del impuesto sobre la renta que deberá pagar por sus ingresos por alquiler, o puede realizar una declaración de impuestos simulada con un software de impuestos disponible para obtener estimaciones.
Contactos Para Tarifas Actualizadas:
TARIFAS DE CONSTRUCCIÓN Y SEGURIDAD. Visite el sitio
Building + Safety
*Nota: Las tarifas se actualizan anualmente. Los solicitantes deben consultar con la Cuidad para obtener las tarifas más actualizadas.
TARIFAS ESCOLAR. Lake Elsinore Valley Unified School District (951) 353-7015 o visite el sitio LEVUSD
SERVICIO DE AGUA Y ALCANTARILLADO. Elsinore Valley
Municipal Water District (EVMWD) (951) 674-3146 or visite el sitio EVMWD
SERVICIO DE GAS. Southern California Gas Company (SoCal Gas) (800) 228-7377 o visite el sitio SoCal Gas
SERVICIO DE ELECTRICIDAD. Southern California Edison
(SCE/Edison) (800) 644-4555 |o visite el sitio SCE
HEALTH DEPARTMENT. County Department of Environmental
Health (RivCoEH) at (951) 955-8980 or visit RivCoEh
Source: City of Bakersfield
510
22 23City of Wildomar ADU Guidebook
Obtener Un Permiso De
Construcción
Obtener un permiso de construcción es un proceso colaborativo que incluye conversación con el personal municipal. El personal se compromete a brindar la orientación y el apoyo necesarios para que los residentes puedan completar con éxito el proceso de solicitud. A continuación, encontrará información útil que le ayudará a prepararse para presentar su solicitud de permiso de construcción.
PASO 1
Completar los requisitos
de solicitud del permiso de
construcción
PASO 2
Presentar la solicitud y pagar
las tarifas requeridas
PASO 3
Responda a cualquier comentario de
la Ciudad de forma completa y lo más
rápido posible para facilitar la rápida
aprobación de su solicitud
PASO 4
Obtener el permiso de construcción
y pagar las tarifas restantes,
incluidas las tarifas de impacto del
desarrollo, las tarifas de conexión y
las tarifas de inspección
PASO 6
¡Obtén el certificado de
ocupación y múdate!
PASO 5
Completar la construcción y las
inspecciones en los intervalos
requeridos
REQUISITOS PARA LA SOLICITUD DE PERMISO
Esta sección incluye listas de verificación útiles que le guiarán por los pasos clave para solicitar un permiso de construcción. Encontrará una lista con los requisitos generales y otra centrada en el plano del sitio. Estas listas no son exhaustivas, pero son un excelente punto de partida. Asegúrese de consultar con el personal municipal sobre cualquier requisito adicional que pueda aplicarse a su proyecto.
PRESENTANDO SU SOLICITUD DE PERMISO
Los solicitantes pueden presentar su solicitud en línea a través del Departamento de Construcción y Seguridad. Consulte al sitio Building + Safety Department para obtener la información más reciente sobre cómo presentar. .
CUÁNDO ESPERAR UNA RESPUESTA
Una vez presentada la solicitud completa y pagadas todas las tarifas de revisión de planos, el personal revisará la solicitud para verificar su cumplimiento con el Código Municipal y el Código de Desarrollo. Revisores de Planificación, Edificación, Obras Públicas, Ingeniería, Bomberos, Paisajismo y otros departamentos y divisiones revisarán su solicitud y le enviarán una carta con los comentarios necesarios para lograr el cumplimiento total. Este proceso suele tardar unas dos semanas desde la fecha de presentación y no debe durar más de 15 días.
¿QUÉ HACER SI RECIBE COMENTARIOS DEL MUNICIPIO?
Una vez recibida la carta de comentarios, será necesario revisar la documentación de la solicitud para abordar todos los comentarios. Una vez revisada, se podrá volver a enviar a la Ciudad para su revisión. Normalmente, una solicitud de permiso recibe una o dos cartas de comentarios antes de la aprobación del permiso de construcción. Sin embargo, la Ciudad debe emitir una decisión final dentro de los 60 days posteriores a la presentación de la solicitud.
Verifique antes de aplicar:
Consulte la página web del Programa de ADU Preaprobadas de la Ciudad para obtener la información más actualizada sobre cómo solicitar un permiso.
Planos Preaprobados
511
24 25City of Wildomar ADU Guidebook
SOLICITUD DE PERMISO DE CONSTRUCCIÓN
Formulario proporcionado por
la Ciudad con información
básica sobre el propietario, la
propiedad y la propuesta del
proyecto
Formulario De
Solicitud
Formulario proporcionado por
la Ciudad que solo es
necesario si se demuele o
modifica una estructura
existente como parte de la
construcción de la vivienda
accesoria
Formulario De
Solicitud De
Permiso De
Demolición
Carta del propietario que
describa cómo se usará la ADU
e indica si la vivienda auxiliar se
usará para familiares o para
fines de alquiler
Declaración
Escrita
Carta obtenida de EVMWD
que certifica que existe la
disponibilidad y capacidad
adecuadas para los servicios
de agua y alcantarillado para
la unidad de vivienda adicional
propuesta
Carta De
Compromiso De
Servicio
Plano personalizado creado
para el propietario por un
arquitecto, o, puede optar por
utilizar uno de los Planos
Plano Del Sitio
Carta obtenida de EVMWD
que confirma que se han
cumplido sus requisitos
Carta De
Verificación
PLANO DEL SITIO
Nombre, dirección e información de contacto del
solicitante
Nombre, dirección e información de contacto del
propietario del inmueble, si es diferente del solicitante Número de parcela catastral de la propiedad donde
se propone la ADU
Dimensiones de la propiedad
Ubicación y dimensiones de todas las estructuras
existentes y propuestas
Ubicación y dimensiones de todas las servidumbres,
pozos, fosas sépticas, líneas de drenaje, pozos de
infiltración existentes, estructuras de drenaje y servicios públicos
Dimensiones, ubicación y nombres de todas las calles
adyacentes, ya sean públicas o privadas, indicando la
ubicación del eje de la calle y todas las mejoras
existentes, como banquetas, canalones, y cortes de
acera
Líneas topográficas o ubicación y dirección de la
pendiente
Retranqueos desde todos los límites de la propiedad
Métodos de circulación, incluyendo entrada y salida,
acceso, patios, caminos de acceso, áreas de
estacionamiento, paisajismo, muros o cercas
Acceso independiente a la unidad exterior desde la
calle. No es posible acceder a ella desde el interior
de la vivienda principal
Se utilizarán muros, paisajismo, elementos
arquitectónicos y otros métodos para garantizar que la
ADU sea compatible con el vecindario
Las viviendas ubicadas a 150 pies o más de una calle
pública deberán contar con acceso transitable en
cualquier condición climática para vehículos de
emergencia, según lo exige el Departamento de
Bomberos del Condado de Riverside
Indique el tamaño del subpanel y proporcione un
cálculo de carga eléctrica del panel existente para
verificar que la capacidad del panel existente sea
suficiente para soportar la carga existente y el nuevo
subpanel
Lista De Verificación De La
Solicitud
SOLICITUD DE PERMISO DE CONSTRUCCIÓN
Formulario proporcionado por
la Ciudad con información
básica sobre el propietario, la
propiedad y la propuesta del
proyecto
Formulario De
Solicitud
Formulario proporcionado por
la Ciudad que solo es
necesario si se demuele o
modifica una estructura
existente como parte de la
construcción de la vivienda
accesoria
Formulario De
Solicitud De
Permiso De
Demolición
Carta del propietario que
describa cómo se usará la ADU
e indica si la vivienda auxiliar se
usará para familiares o para
fines de alquiler
Declaración
Escrita
Carta obtenida de EVMWD
que certifica que existe la
disponibilidad y capacidad
adecuadas para los servicios
de agua y alcantarillado para
la unidad de vivienda adicional
propuesta
Carta De
Compromiso De
Servicio
Plano personalizado creado
para el propietario por un
arquitecto, o, puede optar por
utilizar uno de los Planos
Plano Del Sitio
Carta obtenida de EVMWD
que confirma que se han
cumplido sus requisitos
Carta De
Verificación
PLANO DEL SITIO
Nombre, dirección e información de contacto del
solicitante
Nombre, dirección e información de contacto del
propietario del inmueble, si es diferente del solicitante Número de parcela catastral de la propiedad donde
se propone la ADU
Dimensiones de la propiedad
Ubicación y dimensiones de todas las estructuras
existentes y propuestas
Ubicación y dimensiones de todas las servidumbres,
pozos, fosas sépticas, líneas de drenaje, pozos de
infiltración existentes, estructuras de drenaje y servicios públicos
Dimensiones, ubicación y nombres de todas las calles
adyacentes, ya sean públicas o privadas, indicando la
ubicación del eje de la calle y todas las mejoras
existentes, como banquetas, canalones, y cortes de
acera
Líneas topográficas o ubicación y dirección de la
pendiente
Retranqueos desde todos los límites de la propiedad
Métodos de circulación, incluyendo entrada y salida,
acceso, patios, caminos de acceso, áreas de
estacionamiento, paisajismo, muros o cercas
Acceso independiente a la unidad exterior desde la
calle. No es posible acceder a ella desde el interior
de la vivienda principal
Se utilizarán muros, paisajismo, elementos
arquitectónicos y otros métodos para garantizar que la
ADU sea compatible con el vecindario
Las viviendas ubicadas a 150 pies o más de una calle
pública deberán contar con acceso transitable en
cualquier condición climática para vehículos de
emergencia, según lo exige el Departamento de
Bomberos del Condado de Riverside
Indique el tamaño del subpanel y proporcione un
cálculo de carga eléctrica del panel existente para
verificar que la capacidad del panel existente sea
suficiente para soportar la carga existente y el nuevo
subpanel
Los formularios necesarios están
disponibles en el sitio web del
Departamento de Edificación y
Seguridad
Los Planos Preaprobados están
disponibles en el sitio web
PRADU de la Ciudad
Después De Que Envíes Tu Permiso:
La ciudad tiene 60 días para aprobar o denegar su solicitud. Si se necesitan modificaciones, recibirá una respuesta en un plazo de 15 días—para que nunca se quede con la duda de qué sucederá a continuación.
Lista De Verificación De La
Solicitud
q
Carta obtenida de EVMWD
que certifica que existe la
disponibilidad y capacidad
adecuadas para los servicios
de agua y alcantarillado para
la unidad de vivienda adicional
propuesta
Carta De
Compromiso De
Servicio
Plano personalizado creado
para el propietario por un
arquitecto, o, puede optar por
utilizar uno de los Planos
Preaprobados por la ciudad
Plano Del Sitio
Plano personalizado creado
para el propietario por un
arquitecto, o, puede optar por
utilizar uno de los Planos
Preaprobados por la ciudad
Alzados
Carta obtenida de EVMWD
que confirma que se han
cumplido sus requisitos
Carta De
Verificación
ubicación del eje de la calle y todas las mejoras
existentes, como banquetas, canalones, y cortes de
acera
Líneas topográficas o ubicación y dirección de la
pendiente
Retranqueos desde todos los límites de la propiedad
cálculo de carga eléctrica del panel existente para
verificar que la capacidad del panel existente sea
suficiente para soportar la carga existente y el nuevo
subpanel
512
26 27City of Wildomar ADU Guidebook
Programa de ADU
Preaprobados
El Programa de Planes de ADU Preaprobados de la Ciudad proporciona planos de ADU preaprobados que se han puesto a disposición del público de forma gratuita para que cualquier persona pueda utilizarlos. A través del Programa de ADU Preaprobados, la Ciudad ofrece planos de ADU gratuitos que ya han sido preaprobados por el personal de la Ciudad, lo que agiliza el proceso de revisión de permisos. Estos planos son un gran beneficio para la comunidad, ya que ahorran al propietario del inmueble costos y tiempo significativos. Los propietarios no necesitan contratar consultores privados para crear un conjunto de planos, no necesitan dedicar tiempo al desarrollo del diseño y, dado que los Planes Preaprobados ya han sido revisados por la Ciudad, se reduce el tiempo que su solicitud de permiso permanece en revisión
CONJUNTOS DE PLANOS DE ADU PREAPROBADOS
Aquí tiene un vistazo a los planos de construcción preaprobados de la Ciudad.
Puede elegir entre tres estilos arquitectónicos con opciones de estudio, 1, 2 o 3 dormitorios, y dos diseños de porche. Los planos completos están disponibles con un solo clic en el sitio web de la Ciudad, con enlaces junto a cada vista previa.
USO DE PLANES PREAPROBADOS
Los Planes Preaprobados son simples y fáciles de usar. Comience seleccionando un estilo arquitectónico, luego una distribución (floor plan), y después siga los procedimientos de revisión de permisos al final de esta sección.
Los Planos Preaprobados
están disponibles en el sitio
web PRADU de la ciudad
Source: Google Earth
513
28 29City of Wildomar ADU Guidebook
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
Tamaño de la Unidad
ESTUDIO
493 pies cuadrados
1 DORMITORIO
646 pies cuadrados
A continuación, seleccione el diseño de unidad que prefiere. Hay seis diseños diferentes con una variedad de números de dormitorios.
También está disponible la opción de agregar un porche frontal.
Astilo Arquitectónico
Los Planes Preaprobados están disponibles en uno de los tres estilos que se muestran a continuación. Seleccione cuál de los tres estilos prefiere. 2 DORMITORIOS
749-1086 pies cuadrados
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
3 DORMITORIOS
994-1195 pies cuadrados
CRAFTSMAN MONTEREY FARMHOUSE MODERNO
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
514
30 31City of Wildomar
ADU Guidebook
Craftsman | Estudio
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
ESTUDIO
493 pies cuadrados
Craftsman | 1 Dormitorio
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
1 DORMITORIO
646 pies cuadrados
515
32 33City of Wildomar ADU Guidebook
Craftsman | 2 Dormitorios Opción A
2 DORMITORIOS | Opción A
749 pies cuadrados
Craftsman | 2 Dormitorios Opción A c/porche
2 DORMITORIOS | Opción A c/porche
1104 pies cuadrados
REF.
135 SF
BEDROOM
136 SF
BEDROOM
BATH
LIVING
KITCHEN
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
14' - 9"
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
516
34 35City of Wildomar ADU Guidebook
Craftsman | 2 Dormitorios Opción B
2 DORMITORIOS | Opción B
1139 pies cuadrados
Craftsman | 3 Dormitorios Opción A
3 DORMITORIOS | Opción A
994 pies cuadrados
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
D W
REF.
LIVING
BATH
BATH
KITCHEN
ALTERNATE
WALK-IN CLOSET
126 SF / 150 SF
BEDROOM
130 SF
BEDROOM
31' - 0"
34' - 0"
517
36 37City of Wildomar ADU Guidebook
Craftsman | 3 Dormitorios Opción A c/porche Craftsman | 3 Dormitorios Opción B 3 DORMITORIOS | Opción A c/porche
1104 pies cuadrados
3 DORMITORIOS | Opción B
1195 pies cuadrados
D
W
REF.
BEDROOM
154 SF
BEDROOM
144 SF
BEDROOM
LIVING
BATH
BATH
KITCHEN
31' - 0"
43' - 0"
15' - 4" 15' - 8"
9' - 0" 34' - 0"
126 SF / 150 SF
27' - 10"
ALTERNATE
WALK-IN CLOSET
REF.
BATH 143 SF
BEDROOM
151 SF
BEDROOM
146 SF
BEDROOM
LIVING
KITCHEN
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
15' - 1 1/2"
518
38 39City of Wildomar ADU Guidebook
Monterey | Estudio
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
ESTUDIO
493 pies cuadrados
Monterey | 1 Dormitorio
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
1 DORMITORIO
646 pies cuadrados
519
40 41City of Wildomar
ADU Guidebook
Monterey | 2 Dormitorios Opción A
2 DORMITORIOS | Opción A
749 pies cuadrados
Monterey | 2 Dormitorios Opción A c/porche
2 DORMITORIOS | Opción A c/porche
1067 pies cuadrados
REF.
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
14' - 9"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
520
42 43City of Wildomar ADU Guidebook
Monterey | 2 Dormitorios Opción B Monterey | 3 Dormitorios Opción A 2 DORMITORIOS | Opción B
1054 pies cuadrados
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
3 DORMITORIOS | Opción A
994 pies cuadrados
D W
REF.
LIVING
BATH
BATH
KITCHEN
126 SF / 150 SF
BEDROOM
BEDROOM
31' - 0"
34' - 0"
130 SF
ALTERNATE
WALK-IN CLOSET
521
44 45City of Wildomar ADU Guidebook
Monterey | 3 Dormitorios Opción A c/porche Monterey | 3 Dormitorios Opción B 3 DORMITORIOS | Opción A c/porche
1067 pies cuadrados
3 DORMITORIOS | Opción B
1195 pies cuadrados
D W
REF.
BEDROOM
154 SF
BEDROOM
144 SF
BEDROOM
LIVING
BATH
BATH
KITCHEN
31' - 0"
43' - 0"
15' - 4" 15' - 8"
9' - 0" 34' - 0"
126 SF / 150 SF
27' - 10"
ALTERNATE
WALK-IN CLOSET
REF.
BATH
LIVING
KITCHEN
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
15' - 1 1/2"
522
46 47City of Wildomar ADU Guidebook
Farmhouse Moderno | Estudio
REF.
BATH
LIVING
KITCHEN 19' - 5 1/2"
17' - 0"
29' - 0"
ESTUDIO
493 pies cuadrados
Farmhouse Moderno | 1 Dormitorio
REF.
BEDROOM
BATH
KITCHEN
LIVING
15' - 1 1/2"
177 SF
38' - 0"
17' - 0"
1 DORMITORIO
646 pies cuadrados
523
48 49City of Wildomar ADU Guidebook
Farmhouse Moderno | 2 Dormitorios Opción A
2 DORMITORIOS | Opción A
749 pies cuadrados
Farmhouse Moderno | 2 Dormitorios Opción A c/porche
2 DORMITORIOS | Opción A c/porche
1086 pies cuadrados
REF.
LIVING
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
14' - 9"
BEDROOM BEDROOM
BATH
KITCHEN
135 SF 136 SF
REF.
14' - 9"
28' - 0"
14' - 0" 21' - 0"
17' - 0" 11' - 0"
35' - 0"
BEDROOM BEDROOM
BATH
LIVING
KITCHEN
135 SF 136 SF
524
50 51City of Wildomar
ADU Guidebook
Farmhouse Moderno | 3 Dormitorios Opción A
REF.
BATH
LIVING
KITCHEN
15' - 1 1/2"
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
3 DORMITORIOS | Opción A
994 pies cuadrados
Farmhouse Moderno | 2 Dormitorios Opción B
2 DORMITORIOS | Opción B
1123 pies cuadrados
D W
REF.
LIVING
BATH
BATH
KITCHEN
126 SF / 150 SF
BEDROOM
BEDROOM
31' - 0"
34' - 0"
130 SF
ALTERNATE
WALK-IN CLOSET
525
52 53City of Wildomar ADU Guidebook
Farmhouse Moderno | 3 Dormitorios Opción B
3 DORMITORIOS | Opción B
1195 pies cuadrados
Farmhouse Moderno | 3 Dormitorios Opción A c/porche
3 DORMITORIOS | Opción A c/porche
1086 pies cuadrados
REF.
BATH
LIVING
KITCHEN
29' - 0"
29' - 0" 9' - 0"
17' - 0" 12' - 0"
38' - 0"
BEDROOM
BEDROOM BEDROOM
146 SF 151 SF
143 SF
15' - 1 1/2"
D W
REF.
BEDROOM
154 SF
BEDROOM
144 SF
BEDROOM
LIVING
BATH
BATH
KITCHEN
31' - 0"
43' - 0"
15' - 4" 15' - 8"
9' - 0" 34' - 0"
126 SF / 150 SF
27' - 10"
ALTERNATE
WALK-IN CLOSET
526
54 55City of Wildomar ADU Guidebook
PASOS CLAVE
Revise los planos disponibles para determinar si son
adecuados para su propiedad. Si tiene dudas o
preguntas, comuníquese con el Departamento de
Planificación.
Descargue los planos preaprobados que ha
seleccionado y los formularios de solicitud necesarios
Personalice los planos preaprobados completando los
campos obligatorios y seleccionando las opciones
disponibles en los planos
Complete y firme los planos preaprobados y los
formularios de solicitud correspondientes
Presente los planos preaprobados, los formularios de
solicitud completos y las tarifas correspondientes al
Departamento de Edificación y Seguridad para su
revisión
Responda a los comentarios de la revisión municipal y
vuelva a enviar la solicitud
Una vez que la solicitud esté lista para su aprobación, cualquier JADU deberán firmar una escritura de
restricción que se registrará en la propiedad
Complete una solicitud de dirección para la nueva
unidad según sea necesario
1 2
3 4
5 6
7 8
La cuidad emitirá su permiso de construcción una vez
que se haya aprobado la solicitud de permiso, se
hayan registrado las escrituras y se hayan pagado las
tarifas correspondientes
Construye tu ADU
Haga que se inspeccione la construcción según lo
exige el Departamento de Edificación y Seguridad
Una vez finalizadas las inspecciones y abonadas las
tarifas correspondientes, se emitirá un Certificado de
Ocupación
¡Felicidades por tu nueva ADU! Ya puedes mudarte
9 10
11 12
13 Uso De Planos
Preaprobados
Preguntas Frecuentes (FAQs)
¿QUÉ ES UNA ADU?
Una ADU (Unidad de Vivienda Accesoria) es una unidad de vivienda secundaria ubicada en una propiedad residencial. Puede ser:
Separada. Una estructura separada de la casa principal, generalmente ubicada en el patio trasero.
Adjunta. Una adición a una vivienda existente que comparte una pared con la vivienda principal.
Conversión interior. Conversión de espacio dentro de la vivienda existente, como un sótano.
Conversión de garaje. Conversión del garaje existente.
Adición sobre garaje. Una adición de un garaje existente que comparte una pared con el garaje.
Junior ADU (JADU). Una unidad más pequeña, de no más de 500 pies cuadrados, que consiste en un espacio acondicionado dentro de las paredes de una vivienda ya existente.
¿PUEDO CONSTRUIR MÁS DE UNA ADU?
Sí. Los terrenos para viviendas unifamiliares pueden permitir una ADU y una JADU. Los terrenos para viviendas multifamiliares pueden permitir hasta dos ADUs separadas.
¿PUEDO CONSTRUIR UNA ADU EN MI PATIO DELANTERO?
Solo si el patio trasero no dispone de espacio suficiente (un mínimo de 800 pies cuadrados con un margen de separación de 4 pies respecto al límite de la propiedad).
¿NECESITO VIVIR EN LA PROPIEDAD?
No se exige que el propietario resida en la vivienda en el caso de las ADU, pero sí es un requisito para las JADU.
¿PUEDO VENDER MI ADU DE FORMA INDEPENDIENTE?
En California, una legislación reciente (AB 1033) permite que las ADUs se vendan por separado como condominios bajo ciertas condiciones. ¿EXISTEN REQUISITOS DE ESTACIONAMIENTO?
Frecuentemente se exime de este requisito si la vivienda accesoria está cerca del transporte público. En caso contrario, pueden aplicarse las normativas locales.
¿EXISTEN REQUISITOS DE DISTANCIA O DE ALTURA?
Sí. Normalmente, se requieren retiros laterales y traseros de 4 pies. Los límites de altura varían según la jurisdicción.
527
56 57City of Wildomar ADU Guidebook
¿QUÉ TAMAÑO PUEDE TENER MI ADU?
Adjunta: ≤50% del la vivienda principal o 1,200 pies cuadrados (lo que sea menor).
Separada: ≤1,200 pies cuadrados
¿PUEDO CONVERTIR MI GARAJE O COBERTIZO EN UNA ADU?
Sí, siempre y cuando cumpla con las normas del código de construcción en materia de saneamiento, vías de evacuación y seguridad. ¿PUEDE UNA ADU SER DOS HISTORIAS O TENER UN SÓTANO?
Sí, dependiendo de las normas de zonificación y construcción locales. ¿SON MÁS BARATAS LAS ADU PREFABRICADAS?
Frecuentemente sí, gracias a la eficiencia de la producción en fábrica, pero los costos de preparación del sitio e instalación siguen siendo aplicables. ¿SON MÁS BARATOS LOS PLANOS ADU PREAPROBADOS?
Sí, debido a que no hay ningún costo por crear los planos. ¿AUMENTARÁN MIS IMPUESTOS SOBRE LA PROPIEDAD?
Lo más probable. Solo se evalúa la superficie nueva construida. Las áreas existentes que no se modifican no se someten a una nueva evaluación. ¿CUÁNTO CUESTA CONSTRUIR UNA ADU?
El costo varía considerablemente según el alcance del trabajo, las condiciones del terreno y si se aprovechan beneficios financieros como Planos Preaprobados o la exención de la tarifa de conexión al servicio eléctrico. Los costos pueden oscilar entre aproximadamente $50,000 a más de $300,000. ¿PUEDO FINANCIAR UNA ADU CON UN PRÉSTAMO DE CAPITAL
PARA EL HOGAR?
Sí. Otras opciones incluyen préstamos para la construcción y programas gubernamentales.
¿NECESITO UN SEGURO POR SEPARADO?
Sí, y los inquilinos deberían contratar un seguro de inquilino. ¿PUEDO UTILIZAR MI ADU COMO ALOJAMIENTO DE ALQUILER A
CORTO PLAZO?
No. Los alquileres deben ser superiores a 30 días.
¿PUEDO UTILIZAR MI ADU PARA FAMILIARES O INVITADOS?
Sí. Las viviendas accesorias son ideales para la convivencia de varias generaciones.
¿SON LAS ADU ADECUADAS PARA LAS PERSONAS MAYORES?
Absolutamente. Ofrecen privacidad, cercanía a la familia y la posibilidad de envejecer en el propio hogar.
Contactos de la Ciudad
Departamento De
Construcción Y Seguridad
[email protected]
CITY CONTACTS
Ciudad de Wildomar (951) 677-7751
M-F 7:30AM – 6:00PM
Departamento De Obras
Públicas Y Servicios De
Ingeniería
developmentengineering
@wildomar.gov
Departamento De
Planificación
[email protected]
Códig
CIUDAD
Planos
Web
Inform
ESTADO
Califo
Housin
Comm
2025
AARP
Devel
Occup
Remov
ADU C
528
58 59City of Wildomar ADU Guidebook
References
FINANCIACIÓN LOCAL
CalHFA https://www.calhfa.ca.gov/apps
/rates/
Habitat for Humanity
Riverside
https://www.habitatriverside.org/
Código Municipal https://ecode360.com/4412913
9 CIUDAD DE WILDOMAR
Planos Preapobado Página
Web
https://www.wildomar.gov/439/
Pre-Approved-ADU-Program-PRA
DU
Información De Parcelas https://wildomar.maps.arcgis.com /apps/webapp
viewer/index.html?id=e9ca066fe
bb2435bbbafa68a
5fe5ae1
ESTADO DE CALIFORNIA
California Department of
Housing and
CommunityDevelopment’s
2025 ADU Handbook
https://www.hcd.ca.gov/policy-a
nd-research/accessory-dwelling-u
nits
AARP Expanding ADU
Development and
Occupancy: Solutions for
Removing Local Barriers to
ADU Construction
https://www.aarp.org/livable-co
mmunities/housing/info-2021/ad
u-model-state-act-and-local-ordin
ance.html?msockid=25d21330bbf
1635f3be10543ba1d622f
California Tenants: A Guide
to Residential Tenants’ and
Landlords’ Rights and
Responsibilities
https://www4.courts.ca.gov/doc
uments/California-Tenants-Guide.
pdf
FINANCIACIÓN LOCAL
CalHFA https://www.calhfa.ca.gov/apps
/rates/
Habitat for Humanity
Riverside
https://www.habitatriverside.org/
Código Municipal https://ecode360.com/4412913
9 CIUDAD DE WILDOMAR
Planos Preapobado Página
Web
https://www.wildomar.gov/439/
Pre-Approved-ADU-Program-PRA
DU
Información De Parcelas https://wildomar.maps.arcgis.com /apps/webapp
viewer/index.html?id=e9ca066fe
bb2435bbbafa68a
5fe5ae1
ESTADO DE CALIFORNIA
California Department of
Housing and
CommunityDevelopment’s
2025 ADU Handbook
https://www.hcd.ca.gov/policy-a
nd-research/accessory-dwelling-u
nits
AARP Expanding ADU
Development and
Occupancy: Solutions for
Removing Local Barriers to
ADU Construction
https://www.aarp.org/livable-co
mmunities/housing/info-2021/ad
u-model-state-act-and-local-ordin
ance.html?msockid=25d21330bbf
1635f3be10543ba1d622f
California Tenants: A Guide
to Residential Tenants’ and
Landlords’ Rights and
Responsibilities
https://www4.courts.ca.gov/doc
uments/California-Tenants-Guide.
pdf
Glosario
Unidad de vivienda accesoria (ADU). El Departamento de Vivienda y Desarrollo del Estado de California define una ADU como: “accesorio a una residencia principal y cuenta con instalaciones independientes de vivienda completa para una o más personas. Las ADU están “separadas de”, “adjuntas a” o ubicadas dentro la vivienda principal propuesta o existente. Esto incluye garajes adjuntos, áreas de almacenamiento o espacios similares, y estructuras auxiliares. La ADU también puede ser separada de la vivienda principal, incluidas los garajes, propuesta o existente, siempre que estén ubicados en el mismo lote” (HCD ADU Handbook: 21).
Estructura accesoria. Una estructura subordinada más pequeña a una estructura primaria. Un cobertizo, terraza o ADU es una estructura auxiliar en una propiedad residencial con una vivienda principal.
Número de Parcela del Tasador (APN). Un identificador numérico asignado a cada parcela en la ciudad que se utiliza principalmente para fines de impuestos a la propiedad.
Tarifas de Impacto en el Desarrollo. Tarifas que se cobran antes de la emisión de un permiso de construcción que cubre los impactos del desarrollo.
Por ejemplo, una nueva casa de más de 750 pies cuadrados pagará las tarifas de impacto escolar, ya que la casa será parte del distrito escolar y cualquier niño que viva en el hogar se beneficiará de los servicios educativos prestados.
Unidad de Vivienda. Vivienda donde hay dormitorios, cocina, baño, y otras instalaciones y servicios. Una unidad de vivienda puede ser una ADU, un apartamento, casa adosada, casa unifamiliar y otras.
Servidumbre. Un área restringida legalmente vinculante en una propiedad.
Las servidumbres son generalmente presentes en propiedades residenciales a lo largo de los patios laterales y traseros para servicios públicos, como electricidad e internet. Estas áreas no pueden tener una estructura colocada en ellas, y en caso de trabajos de mantenimiento de los servicios en ellas, cualquier árbol, arbusto, pavimento, y estructura serán removidas como parte del mantenimiento.
Desarrollo de relleno. Desarrollo que ocurre en propiedades que ya tienen servicios públicos, como agua y electricidad. El nuevo desarrollo aprovecha la infraestructura existente y es un mejor uso que el uso del sitio actual.
Entrada y salida. Entrada significa entrada o punto de acceso al sitio o edificio, y salida significa el punto de salida del sitio o edificio.
Unidad de Vivienda Auxiliar Junior (JADU). El Departamento de Vivienda y Desarrollo del Estado de California define una JADU como: “una […] unidad que no tiene más de 500 pies cuadrados de tamaño y está contenida completamente dentro de una casa unifamiliar. Una JADU puede incluir instalaciones sanitarias separadas o puede compartir las instalaciones sanitarias con la estructura existente” (HCD ADU Handbook: 9).
Vivienda principal. La estructura y/o uso predominante en el sitio. Una vivienda unifamiliar que es más grande que una unidad secundaria en la propiedad es la principal, donde la unidad secundaria es la unidad de vivienda accesoria.
529
60 61City of Wildomar
ADU Guidebook
Retranqueo. Una distancia dentro de una propiedad que delinea qué tan cerca puede estar una estructura al límite de la propiedad. Por ejemplo, un retranqueo de 5 pies significa que la estructura no puede estar a menos de 5 pies de esa línea de propiedad.
Topografía. Una forma de medir y representar los cambios en la elevación del terreno. Un mapa topográfico se compone de una serie de líneas dibujadas a intervalos regulares entre sí, como intervalos de 5 pies. Cuando más cerca estén las líneas, más empinadas será la pendiente del terreno.
Cuando más lejos están las líneas, la pendiente del terreno será más plana.
Zonificación. Un área geográfica que establece la densidad de unidades de vivienda, el retranqueo, la altura, y otras normas de desarrollo para la propiedad dentro del área definida.
*Las definiciones anteriores no son definiciones legales.
Esta sección está escrita en cumplimiento parcial de los requisitos de financiación de la Asociación de Gobiernos del Sur de California.
DEFINICIÓN DEL LÍMITE DEL ÁREA DEL PROYECTO
El límite del área del proyecto está definido por el límite de la ciudad, excluyendo las zonas que no permiten unidades de vivienda accesorias o las zonas que no permiten el uso residencial. Las zonas excluidas incluyen Comercial General (C-G), Comercial de Carretera (C-H), Centro Médico (M-C), Manufactura/Industrial (M-I), Zona de Áreas Abiertas (O-S) y Servicios Públicos (P-F). Gran parte de las zonas residenciales de baja densidad de la ciudad no cumplen con la definición de desarrollo de relleno urbano de REAP 1.0 —Residencial Montañosa (R-M), Residencial Agrícola (R-A), Residencial Rural (R-R), Residencial Baja (R-1) y Subdivisiones de Casas Móviles y Parques de Casas Móviles (R-T)— sin embargo, estas zonas están incluidas dentro del límite del proyecto para cumplir con la legislación estatal.
La Sección 66310 del Código Gubernamental exige que las jurisdicciones locales permitan unidades de vivienda accesorias en todas las zonas que permiten usos unifamiliares y multifamiliares. Además, partes de la Zona Residencial Montañosa (R-M) en el extremo sur de la ciudad se encuentran dentro de terrenos protegidos por el Servicio Forestal de los Estados Unidos y la Comisión de Tierras del Estado de California; estas áreas han sido excluidas del límite del área del proyecto, ya que no se permite el desarrollo residencial privado en estos terrenos protegidos.
CARRETERAS PRINCIPALES
El área del proyecto está dividida por la Interestatal 15 (también conocida como Autopista del Valle de Temecula), que atraviesa la ciudad de forma central, desde el noroeste hasta el sureste. Otras carreteras importantes incluyen Clinton Keith Road, con una orientación general este-oeste; Bundy Canyon Road, también con orientación general este-oeste; Grand Avenue, que va del noroeste al suroeste; Palomar Street, que también va del noroeste al suroeste; Mission Trail, que recorre la mitad norte de la ciudad de norte a sur y termina en Palomar Street; y Corydon Road, que va del suroeste al noreste.
PRINCIPALES LUGARES DE INTERÉS
Entre los principales puntos de referencia de la ciudad se encuentran las estribaciones de las montañas Santa Ana y Santa Rosa al sur, Memorial Hill y una zona de espacios verdes al norte, el hospital Southwest Healthcare Inland Valley, ubicado en la parte sur de la ciudad, junto a la Interestatal 15, que marca la entrada a la ciudad desde el sur, y la escuela secundaria Elsinore High School, en la parte norte de la ciudad, junto a Bundy Canyon Road.
TIERRAS AGRÍCOLAS, NATURALES Y DE USO PRODUCTIVO
En la ciudad no se han identificado terrenos agrícolas. Partes del distrito de zona residencial montañosa (R-M), en la zona más meridional de la ciudad, se encuentran dentro de terrenos protegidos por el Servicio Forestal de los Estados Unidos y la Comisión de Tierras del Estado de California. Estas áreas se han excluido del área del proyecto, ya que no se permite el desarrollo residencial privado en zonas de conservación.
CARACTERÍSTICAS URBANAS
Entre los principales destinos de la ciudad se encuentran el Southwest Healthcare Inland Valley Hospital, la escuela secundaria Elsinore High School, así como la variedad de establecimientos comerciales a lo largo del corredor de la Interestatal 15 que ofrecen restaurantes, supermercados, servicios de reparación del hogar, servicios médicos, gimnasios y una variedad de otros comercios y servicios. La ciudad de Wildomar cuenta con las rutas 8 y 23 de la Autoridad de Tránsito de Riverside. La ruta 8 conecta Wildomar con la ciudad de Lake Elsinore a través de Wildomar Trail y Palomar Street. La ruta 23 conecta Wildomar con Murrieta a través de Palomar Street y Wildomar Trail. La ciudad está mayormente urbanizada, aunque presenta zonas sin desarrollar en los extremos suroeste y noreste. Grandes áreas en las estribaciones de las montañas Santa Ana y Santa Rosa tienen infraestructura o desarrollo de construcción limitados o inexistentes. Además, las zonas de ladera al noreste de la ciudad incluyen una combinación de espacios verdes protegidos localmente y zonas residenciales de baja densidad, muchas de las cuales tienen infraestructura y desarrollo limitados o inexistentes. La mayor parte del desarrollo comercial de la ciudad se concentra a lo largo del corredor de la Interestatal 15 y las carreteras principales que lo cruzan. Estas intersecciones con la Interestatal 15 constituyen los centros urbanos de la ciudad. Los parques de la ciudad incluyen el Parque Marna O’Brien, el Parque Málaga, el Parque Windsong y el Parque Regency Heritage.
530
62 Source: Google Earth
531
ACCESSORY DWELLING
UNIT (ADU)
PERMIT-READY, PRE-APPROVED
ADU ARCHITECURAL PLANS AND GUIDANCE HANDBOOK
Wildomar City Council
3/11/2026
Prepared for:
Prepared by:
532
493 SF
BATH
LIVING
29' - 0"
17' - 0"
10' - 7" 24" 10' - 11 1/2" 9' - 10" KITCHEN
BR
BATH
LIVING
38' - 0"
17' - 0"
12' - 7 1/2"
13' - 3 1/2"
TYP.
24"
646 SF
15' - 2 1/2"
KITCHEN
994 SF
LIVING
BR
BATH
BR BR
29' - 0"
38' - 0"
17' - 0" 12' - 0"
10' - 10"
12' - 7 1/2"
11' - 7 1/2"
12' - 5"
9' - 0" 29' - 0"
15' - 2 1/2"
TYP.
24"
KITCHEN
14' - 10"
749 SF
28' - 0"
35' - 0"
10' - 1" 10' - 7 1/2"
12' - 7 1/2"
17' - 0" 11' - 0"
14' - 0" 21' - 0" BR BR
LIVING
BATH
KITCHEN
WRCOG - WILDOMAR ADU
FLOOR PLANS (1 BATH) A1
09/18/25
STUDIO 1 BEDROOM 1 BATH 3 BEDROOM 1 BATH
0 SCALE:
4' - 0" 8' - 0" 16' - 0"
1/8" = 1' - 0"
2 BEDROOM 1 BATH
533
D
W
D
W
12' - 8"
14' - 8"
WALK-IN CLOSET
(ADD ALTERNATE)
1,198 SF
31' - 0"
34' - 0" 9' - 0"
10' - 1"
10' - 0 1/2"
14' - 8"
13' - 10"
12' - 3"
11' - 6"
TYP.
24"
13' - 10 1/2" 27' - 5"
43' - 0"
15' - 0" 16' - 0"
4' - 0"
BR BR
LIVING
BR
BATH
BATH
KITCHEN
1,054 SF
BR
BR
BATH
LIVING
14' - 8"
WALK 12' - 8" -IN CLOSET
(ADD ALTERNATE)
BATH
12' - 3"
10' - 1"
10' - 1"
12' - 8"
TYP.
24" 14' - 3"
31' - 0"
34' - 0"
4' - 0"
KITCHEN
WRCOG - WILDOMAR ADU
FLOOR PLANS (2 BATH) A2
09/18/25
2 BEDROOM 2 BATH 3 BEDROOM 2 BATH 0
SCALE:
4' - 0" 8' - 0" 16' - 0"
1/8" = 1' - 0"
31' - 0"
34' - 0"
534
EXPOSED SHINGLE ROOF RAFTERS
MASONRY
VENEER BASE
CONTRASTING
WINDOW TRIM
DIVIDED TOP LITE
WINDOWS
PANEL DOOR
SIDING
535
TILE ROOF AWNING
TILE ROOF WITH EXPOSED SUPPORTS STUCCO
DIVIDED LITE
WINDOWS
WOOD TONE DOOR
536
SHINGLE ROOF
ALTERNATE STANDING
SEAM METAL ROOF
EXPOSED FRAMING DIVIDED LITE
WINDOWS
DIVIDED LITE DOOR
BOARD AND
TONE ON TONE BATTEN SIDING
WINDOW TRIM
537
EXPOSED SHINGLE ROOF RAFTERS
MASONRY
VENEER BASE
CONTRASTING
WINDOW TRIM
DIVIDED TOP LITE
WINDOWS
PANEL DOOR
SIDING
538
TILE ROOF AWNING
TILE ROOF WITH EXPOSED SUPPORTS STUCCO
DIVIDED LITE
WINDOWS
WOOD TONE DOOR
539
SHINGLE ROOF
ALTERNATE STANDING
SEAM METAL ROOF
EXPOSED FRAMING DIVIDED LITE
WINDOWS
DIVIDED LITE DOOR
BOARD AND
TONE ON TONE BATTEN SIDING
WINDOW TRIM
540
SHINGLE ROOF
EXPOSED
FRAMING
MASONRY
VENEER BASE
AND PIERS
CONTRASTING
WINDOW TRIM DIVIDED TOP LITE
WINDOWS SIDING
541
TILE ROOF AND
COVERED PORCH
WITH EXPOSED SUPPORTS
STUCCO
DIVIDED LITE
WOOD TONE DOOR SLIDING DOOR WINDOWS
542
STANDING SEAM
METAL ROOF
ALTERNATE SHINGLE ROOF
EXPOSED FRAMING DIVIDED LITE
WINDOWS
DIVIDED LITE DOOR
BOARD AND
BATTEN SIDING
TONE ON TONE
WINDOW TRIM TRELLIS FRAMING
543
:eE
0 0
0:::
C
w
m
�
0 0
0:::
C
w
m
N
CRAFTSMAN MONTERREY MODERN FARMHOUSE
WRCOG - WILDOMAR ADU
RENDERINGS
09/18/25
A6
544
CITY OF WILDOMAR
CITY COUNCIL REGULAR MEETING
GENERAL BUSINESS
Agenda Staff Report # 3.3
Meeting Date: March 11, 2026
SUBJECT: Introduce and conduct the first reading of an Ordinance that adds a chapter under Title 10 (Vehicles and Traffic) of the Municipal Code relating to bicycles and e-conveyances,
including E-Bikes.
SUBMITTED BY: Abdu Lachgar, Principal Planner
PREPARED BY: Abdu Lachgar, Principal Planner
ACTION:
1. Determine that Ordinance No. _____, is exempt under the California Environmental Quality Act (CEQA) and CEQA Guidelines, pursuant to the common-sense exemption, Section 15061(b)(3) of the CEQA Guidelines, under the general rule making provision.
2. Introduce and conduct the first reading by title only, based on the necessary finding within, for an ordinance entitled:
ORDINANCE NO. ____
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF WILDOMAR, CALIFORNIA, ADDING CHAPTER 10.56 (BIKES, E-BIKES, E-SCOOTERS AND E-SKATEBOARDS) TO TITLE 10 (VEHICLES AND TRAFFIC) OF THE WILDOMAR MUNICIPAL CODE RELATING
TO BICYCLES, ELECTRIC BICYCLES, ELECTRIC SCOOTERS AND ELECTRIC
SKATEBOARDS
3. Direct the City Clerk to schedule the second reading of the Ordinance at the next regular City Council meeting or as soon thereafter as feasible.
SUMMARY:
The City of Wildomar is proposing the adoption of an ordinance which would add Chapter
10.56 to Title 10 of the Wildomar Municipal Code. This ordinance aims to regulate bicycles, electric bicycles (“E-Bikes”), electric scooters (“E-Scooters”), and electric skateboards (“ESkateboards”) (collectively referred to as “E-Conveyances”), in response to increasing public safety concerns.
BACKGROUND:
Over the last few years, the City and the region as a whole have experienced a rise in the number of E-Conveyances operating on streets and bike paths. Common concerns noted in the region include a lack of helmets by E-Conveyance operators, reckless speeds, inattention, carrying too many passengers, and the increased potential for collisions due to use on sidewalks and roadways. The proposed ordinance establishes operational rules, safety requirements, penalties, and enforcement measures to improve public safety and address the risks associated with E-Conveyance use in the community. 545
Prior to preparing this ordinance, the Planning Department thoroughly researched local regulations pertaining to E-Conveyances and contacted other neighboring jurisdictions. Staff found that multiple jurisdictions throughout Southern California were either in the process of implementing similar ordinances, had already adopted them, or were amending existing ordinances to improve safety for their communities and to address the rising concerns related to E-Conveyances. These findings assisted in the development of the proposed ordinance, ensuring alignment with regional safety efforts and incorporating best practices.
DISCUSSION:
The proposed ordinance introduces several key provisions to ensure the safe and responsible operation of bicycles and E-Conveyances. Riders would be required to comply with all traffic laws and traffic-control devices, including stop signs and traffic signals. Helmets would be mandatory for riders, and the use of headphones, earbuds, or other similar audio devices in both ears while operating E-Conveyances would be prohibited, ensuring riders could maintain focus and attentiveness. E-Conveyances must also be equipped with essential safety features, such as a front-facing white light for night riding, as well as reflectors on both wheels and the rear of all bicycles and E-bikes. Riders would be required to park responsibly, avoiding obstructions on sidewalks or public rights-of-way, and utilize designated parking areas.
Parents of minors would be responsible for any fees or penalties associated with a violation of this chapter.
Additionally, riders would be required to stay as close as practicable to the right-hand curb or utilize designated bike lanes. The ordinance would prohibit operating bicycles or EConveyances with more passengers than the device is designed to carry, directly addressing safety concerns related to instability caused by overloading. Riders are restricted from operating bicycles or E-Conveyances at speeds greater than what is reasonable and prudent under the conditions and must avoid endangering people or property. The ordinance would make it unlawful to tamper with or modify an E-bike to increase its speed capability without appropriately replacing the classification label. Persons under the age of 16 would be prohibited from operating a Class 3 E-bike. The ordinance also addresses bike lanes and path usage and would allow riding unless explicitly prohibited by posted signage, with an emphasis on yielding to pedestrians and persons on horseback. This ordinance also prohibits riding or operating a bicycle or E-Conveyance upon any playground, park, or school ground not specifically designated as a bicycle path or route, unless specifically posted as authorized for such use.
Engaging in unsafe actions or reckless behavior is strictly prohibited. Violations of these provisions would be classified as infractions and would be punishable by fines of up to $500.
Additionally, the ordinance may also be enforced through administrative or civil actions as authorized by the Municipal Code. These penalties align with California Vehicle Code standards, ensuring consistent enforcement across the City. These measures collectively aim to enhance public safety, reduce risks to riders and pedestrians, and ensure the responsible use of bicycles and E-Conveyances throughout the City.
The ordinance would establish a comprehensive framework for safer operations of bicycles and E-Conveyances, helping to reduce collisions, and enhance public safety, while remaining in full compliance with state law. The provision of clear guidelines for e-bike usage is critical to the safe of all users of sidewalks and trails within Wildomar. The passage of this ordinance would promote responsible e-bike use while protecting pedestrians, cyclists, and motorists. 546
ENVIRONMENTAL ANALYSIS:
In accordance with the requirements of the California Environmental Quality Act (“CEQA”), Public Resources Code § 21000, et seq., and the CEQA Guidelines, Section § 15000, et seq., Ordinance No. [next in order] is exempt from further environmental review, based on the common sense exemption, CEQA Guideline Section 15061(b)(3), in that the amendments involve general policy and procedure making and it can be seen with certainty that there is no possibility that this code amendment and ordinance adoption may have a significant effect on the environment.
FISCAL IMPACT:
The fiscal impacts associated with the drafting, legal review, and implementation of this ordinance are covered by the Department’s Operating Budget of General Fund.
ATTACHMENTS:
Attach A - MCA 2026-01 Ordinance.docx
Attach B - PPT Final [3-11-26].pdf
547
ORDINANCE NO. ____
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
WILDOMAR, CALIFORNIA, ADDING CHAPTER 10.56 (BIKES,
E-BIKES, E-SCOOTERS AND E-SKATEBOARDS) TO TITLE
10 (VEHICLES AND TRAFFIC) OF THE WILDOMAR
MUNICIPAL CODE RELATING TO BICYCLES, ELECTRIC
BICYCLES, ELECTRIC SCOOTERS AND ELECTRIC
SKATEBOARDS
WHEREAS, electric bicycles, electric scooters, and electric skateboards (collectively, " E-Conveyances") are an ever- growing public safety concern. With the increasing popularity and usage of E- Conveyances, traffic accidents involving individuals operating E- Conveyances and motor vehicles have increased, necessitating rules and regulations applicable to these devices to ensure a safer community; and WHEREAS, individuals involved in E-Conveyance traffic accidents tend to suffer more serious injuries when compared to traditional bicycle accidents; and WHEREAS, collisions involving E-Conveyances and motor vehicles result in greater damage to all vehicles and property involved; and WHEREAS, in accordance with the Wildomar Municipal Code, the City Council has the authority to take action on the proposed municipal code amendment to Title 10 of the Wildomar Municipal Code; and
WHEREAS, in accordance with the Wildomar Municipal Code, the City Council conducted a public meeting on March 11, 2026, at which time interested persons had an opportunity to testify in support of, or opposition to the proposed amendment to Title 10 of the WMC, and at which time the City Council received public testimony concerning said amendment.
THE CITY COUNCIL OF THE CITY OF WILDOMAR HEREBY DOES ORDAIN AS FOLLOWS:
SECTION 1: AMENDMENT OF TITLE 10 OF THE WILDOMAR MUNICIPAL CODE.
Title 10 (Vehicles and Traffic) of the Wildomar Municipal Code is hereby amended to read as illustrated in Exhibit 1 of this Ordinance.
SECTION 2. SEVERABILITY
If any Chapter, subsection, subdivision, sentence, clause, phrase, or portion of this ordinance, is for any reason held to be invalid or unconstitutional by the decision of any 548
court of competent jurisdiction, such decision will not affect the validity of the remaining portions of this ordinance. The City Council hereby declares that it would have adopted this ordinance, and each Chapter, subsection, subdivision, sentence, clause, phrase, or portion thereof, irrespective of the fact that any one or more Sections, subsections, subdivisions, sentences, clauses, phrases, or portions thereof be declared invalid or unconstitutional.
SECTION 3. EFFECTIVE DATE.
This ordinance shall take effect thirty (30) days after its passage by the City Council.
SECTION 4. CITY CLERK ACTION
The City Clerk is authorized and directed to cause this Ordinance to be published within fifteen (15) days after its passage in a newspaper of general circulation and circulated within the City in accordance with Government Code Chapter 36933(a) or, to cause this Ordinance to be published in the manner required by law using the alternative summary and posting procedure authorized under Government Code Chapter 36933(c).
INTRODUCED AND APPROVED FOR FIRST READING this 11th, day of March 2026.
_____________________
Carlos Marquez
Mayor
APPROVED AS TO FORM: ATTEST:
____________________________ ___________________________ Thomas D. Jex Janet Morales, CMC
City Attorney City Clerk
549
EXHIBIT 1
CHAPTER 10.56 (BIKES, E-BIKES, E-SCOOTERS AND E-SKATEBOARDS) OF THE WMC
550
Sections:
10.56.010 Purpose and Intent
10.56.020 Applicability of Traffic Laws
10.56.030 Obedience to Traffic-Control Devices
10.56.040 Riding on Roadway and Bicycle Lanes
10.56.050 Use of Streets Restricted
10.56.060 Yielding Right-Of-Way
10.56.070 Leaving Bicycle Lane
10.56.080 Riding and Operation
10.56.090 Parking
10.56.100 Method of Riding; Number of Riders
10.56.110 Speed
10.56.120 Equipment
10.56.130 Age Restrictions
10.56.140 Use of Headphones or Earbuds
10.56.150 Lights and Reflectors
10.56.160 Designation
10.56.170 Motor Vehicle Usage
10.56.180 Definitions
10.56.190 Enforcement
§ 10.56.010 PURPOSE AND INTENT.
This chapter shall apply to the use of bicycles and E-Conveyances, as defined herein, in conformity with State law, and shall apply to any bicycle or E-Conveyance operated upon any street or sidewalk, right-of-way, public property, or upon any public path set aside for the use of bicycles or E-Conveyances within the City' s jurisdiction. The provisions contained herein are enacted pursuant to Vehicle Code Division 16.7 (Vehicle Code § 39000 et seq.), and any rules and regulations adopted thereunder pertaining to the licensing of bicycles, and California Vehicle Code § 21206 pertaining to the regulation of the operation, use and equipment of bicycles. This chapter is not intended to conflict in any way with the provisions thereof. § 10.56.020 APPLICABILITY OF TRAFFIC LAWS.
Except where California law expressly provides otherwise, every person riding a bicycle or EConveyance upon a street or sidewalk shall be granted or E-Conveyance upon a street or sidewalk shall be granted all of the rights and shall be subject to all of the duties applicable to the 551
driver of a vehicle by the laws of the State pertaining to the rules of the road, or by the terms of this code or other ordinances of this City applicable to the driver of a vehicle, except as to those provisions which by their nature can have no application to bicycles or E-Conveyances, and except as otherwise provided in this Chapter.
§ 10.56.030 OBEDIENCE TO TRAFFIC-CONTROL DEVICES.
It shall be unlawful for any person operating a bicycle or E-Conveyance to fail to obey the instructions of official traffic-control signs and other traffic-control devices applicable to vehicles or bicycles, unless otherwise directed by a police officer. § 10.56.040 RIDING ON ROADWAYS AND BICYCLE LANES.
A) Any person operating a bicycle or E-Conveyance upon a roadway at a speed less than the normal speed of traffic moving in the same direction at such time shall ride as close as practicable to the right- hand curb, edge of the roadway, or bike lane, except under any of the following situations:
1) When overtaking and passing another bicycle, E-Conveyance or vehicle proceeding in the same direction.
2) When preparing for a left turn at an intersection or onto a private road or driveway. 3) When reasonably necessary to avoid conditions (including, but not limited to, fixed or moving objects, vehicles, bicycles, pedestrians, animals, surface hazards, or substandard width lanes) that make it unsafe to continue along the right- hand curb or edge.
B) Any person operating a bicycle or E-Conveyance upon a roadway or a highway, which highway carries traffic in one direction only and has two or more marked traffic lanes, may ride as near the left-hand curb or edge of such roadway as practicable.
C) Persons riding bicycles or E-Conveyances upon a roadway or bike lane shall not ride more than two abreast.
§ 10.56.050 USE OF STREETS RESTRICTED.
Riding or operating a bicycle or E-Conveyance on any street within the City is permitted in accordance with the California Vehicle Code, unless specifically prohibited by this Chapter. § 10.56.060 YIELDING RIGHT-OF-WAY.
The operator of a bicycle or E-Conveyance emerging from an alley, driveway, bicycle path, building or otherwise approaching a sidewalk or sidewalk area shall yield the right-of-way to all pedestrians on such sidewalk or sidewalk area, and upon entering a bicycle lane or roadway, shall yield the right-of-way to all vehicles or bicycles on the roadway. § 10.56.070 LEAVING BICYCLE LANE.
A) Whenever a bicycle lane has been established, any person operating a bicycle or EConveyance upon the roadway at a speed of less than the normal speed of traffic moving in the same direction shall ride within the bicycle lane, except that such person may move 552
out of the lane under any of the following situations:
1) When overtaking and passing another bicycle, vehicle, E- Conveyance or pedestrian within the lane or about to enter the lane if such overtaking and passing cannot be done safely within the lane.
2) When preparing for a left turn at an intersection or onto a private road or driveway. 3) When it is reasonably necessary to leave the bicycle lane to avoid debris or other hazardous conditions (including, but not limited to, fixed or moving objects, vehicles, bicycles, pedestrians, animals, surface hazards, or substandard width lanes). 4) When approaching a place where a right turn is authorized.
B) No person operating a bicycle or E- Conveyance within a bicycle lane shall leave such lane until movement can be made with reasonable safety, and then only after giving the appropriate signal in the manner provided in Vehicle Code Division 11, Chapter 6 (Vehicle Code § 22100 et seq.) in the event that any vehicle may be affected by the movement. § 10.56.080 RIDING AND OPERATION.
A) Riding bicycles and E- Conveyances on any sidewalk, bicycle path, bicycle trail, multi-use trail, or roadway is permitted unless prohibited by appropriate signs authorized by the terms of this Chapter.
B) Whenever any person is riding a bicycle or E-Conveyance upon a bicycle path, or bicycle trail, such person shall yield the right- of-way to any pedestrian or person on horseback and shall give an audible signal before overtaking and passing pedestrians.
C) No person shall ride or operate a bicycle or E-Conveyance upon any playground, park, or school ground not specifically designated as a bicycle path or route, unless specifically posted as authorized for such use.
D) No person shall operate a bicycle or E-Conveyance on a bicycle path or bicycle trail at a speed greater than 20 miles per hour, and in no event at a speed greater than is reasonable or prudent under the existing conditions, or at a speed greater than a posted speed limit, or at a speed which endangers the safety of persons and/ or property.
E) When posted, no person shall operate a bicycle or E-Conveyance at any City special events.
F) The operator of a bicycle or E-Conveyance shall travel in the same direction as vehicles are required to be driven upon the roadway, regardless of whether or not the operator is in the roadway or in a bike lane.
G) The operator of a bicycle or E-Conveyance shall not allow a person riding as a passenger, and a person shall not ride as a passenger, on a bicycle or E-Conveyance upon a highway other than upon or astride a separate seat attached thereto. The section does not apply 553
to any type of bicycle or E-Conveyance with an original factory seat designed to collectively accommodate the operator and passenger. If the passenger is four years of age or younger, or weighs 40 pounds or less, the seat shall have adequate provision for retaining the passenger in place and for protecting the passenger from the moving parts of the bicycle.
H) The City may prohibit the riding or operation of bicycles and E-Conveyances on designated sidewalks or sidewalk segments by posting appropriate signs in accordance with this chapter.
Where such signs are posted, no person may ride or operate a bicycle or E-Conveyance on the posted sidewalk or sidewalk segment.
§ 10.56.090 PARKING.
No person shall leave a bicycle or E-Conveyance lying on its side on any sidewalk, nor park a bicycle or E-Conveyance upon the public right- of-way, including bike lanes and paths, or against a building or at a curb, except in such a manner as to afford the least obstruction to pedestrian traffic. Where appropriate signs are posted, no person shall park a bicycle or E-Conveyance on a public highway in the area designated by those signs. § 10.56.100 METHOD OF RIDING; NUMBER OF RIDERS.
No person operating a bicycle or E-Conveyance shall allow more persons at one time than the number for which the bicycle or E-Conveyance is designed and equipped. § 10.56.110 SPEED.
No person may operate a bicycle or E-Conveyance at a speed greater than is reasonable and prudent under the existing conditions, and in no event at a speed which endangers the safety of persons or property. Posted speed limits govern where installed. In the absence of a posted limit, the reasonable and prudent standard applies. On City-owned trails, paths, and parks, each bicycle and E-Conveyance operator must comply with any speed limit that is posted for that facility, and must not travel at a speed greater than is reasonable and prudent under existing conditions or that endangers the safety of persons or property. § 10.56.120 EQUIPMENT.
Every bicycle, Electric Bicycle, Motorized Bicycle, and other E-Conveyance, when operated within the City, must comply with all applicable equipment requirements of the California Vehicle Code, including, without limitation, section 21201 and any device-specific provisions required under California law, as well as any additional requirements set forth in this chapter. § 10.56.130 AGE RESTRICTIONS.
A) Minors under 18. A person under 18 years of age must wear a properly fitted and fastened bicycle helmet that meets applicable safety standards when operating a bicycle or Electric Bicycle, or riding as a passenger on a bicycle or Electric Bicycle, on any street, bikeway, or other public bicycle path or trail within the City, including when riding in a child seat or in a trailer towed by a bicycle. This subsection is intended to be consistent with Vehicle Code section 21212, as that section may be amended from time to time.
B) Class 3 Electric Bicycles – age and helmet. A person under 16 years of age must not operate a Class 3 Electric Bicycle. A person must not operate a Class 3 Electric Bicycle, or ride as a passenger on a Class 3 Electric Bicycle, on any street, bikeway, or other public bicycle path or trail within the City unless that person is wearing a properly fitted and fastened bicycle helmet that 554
meets applicable safety standards. This subsection is intended to be consistent with Vehicle Code section 21213, as that section may be amended from time to time.
C) Sale of Electric Bicycles to minors. No person may sell a Class 3 Electric Bicycle to a person under 16 years of age. This subsection is intended to be consistent with Vehicle Code section 21212.5, as that section may be amended from time to time.
D) Enforcement. The helmet and age requirements in this section may be enforced through citations issued under state law or this code, including any diversion or correction procedures that may be provided in Vehicle Code section 21212 or similar state provisions, as those provisions may be amended from time to time.
§ 10.56.140 USE OF HEADPHONES OR EARBUDS.
A) A person operating a bicycle or E-Conveyance must not wear headphones, earphones, earbuds, earplugs, or any similar device in a way that covers, rests on, or is inserted in both ears while operating on any street, highway, bikeway, or bicycle path within the City.
B) A person operating a bicycle or E-Conveyance may use a single earbud, earphone, or similar device in one ear, so long as the other ear remains unobstructed and the device is not otherwise prohibited by California law.
C) This section is intended to be consistent with California Vehicle Code section 27400, as that section may be amended from time to time.
§ 10.56.150 LIGHTS AND REFLECTORS.
Every bicycle and Electric Bicycle operated within the City shall comply with the lighting and reflector requirements set forth in California Vehicle Code section 21201, as that section may be amended from time to time. These requirements generally include, among other things, the use of a white front light, a red rear reflector or light, and wheel or side reflectors when operated during hours of darkness.
§ 10.56.160 DESIGNATION.
A) The City's Director of Public Works/City Engineer is authorized to erect or place and maintain signs on any sidewalk, roadway, or public property prohibiting the riding of bicycles and/or EConveyances by any person thereon.
B) The City' s Director of Public Works is authorized to erect or place and maintain signs upon any street, or adjacent to any street in the City, indicating the existence of a bicycle path, lane or route, or otherwise regulating the operation and use of vehicles, bicycles, and E-Conveyances with respect thereto, as long as the same are consistent with this Chapter.
Where such a sign is erected, such other designation, including but not limited to appropriate painting or such other devices as the City' s Director of Public Works shall determine, will provide sufficient notice of the existence of the bicycle path, lane or route. Said signage shall conform with the provisions established by the California Manual on Uniform Traffic Control Devices. § 10.56.170 MOTOR VEHICLE USAGE.
No person shall operate any motorized vehicle upon any bicycle lane or path, except to park when permitted, or to enter or leave the roadway, or to prepare for a turn within a distance of 200 feet from the intersection. Nothing in this section shall be deemed or construed to prohibit any bus 555
owned and operated by a public transportation district or other authorized transportation agencies from driving upon such bicycle lanes within 150 feet of any bus stop approved by the City. Motor vehicle parking is prohibited in bicycle lanes, provided such restriction is appropriately posted.
This section does not prohibit the use of a motorized bicycle in a bicycle lane, pursuant to Vehicle Code § 21207.5, at a speed no greater than is reasonable or prudent, having due regard for visibility, traffic conditions, and the condition of the roadway surface of the bicycle lane, and in a manner which does not endanger the safety of persons or property. § 10.56.180 DEFINITIONS.
For purposes of this chapter, the following terms have the meanings set forth in this section.
Where a term is defined in the California Vehicle Code, that statutory definition governs and is incorporated here by reference, as it may be amended from time to time.
BICYCLE. Any device upon which a person may ride which is propelled by human power through a system of belts, chains or gears, and having one or more wheels. " Bike" shall mean the same as " Bicycle," and the terms may be used interchangeably.
BICYCLE LANE. The portion of the roadway which has been separated from any vehicular lanes by a solid white line or other pavement marking or defined for bike riders by appropriate signage.
BICYCLE PATH OR BICYCLE TRAIL. A path that provides a completely separated right- of-way from vehicular traffic designated for the exclusive use of bicycles and pedestrians with crossflows by motorists minimized.
BICYCLE ROUTE. A suggested route of travel for bicycle riders. A " bicycle route" may offer no physical protection to the bike rider and is normally defined for the bicycle rider only by a sign indicating " bike route," which defines a suggested route of a bicycle system and provides a certain awareness for the motorist that bicycle riders are sharing the roadway.
E-CONVEYANCE. Includes any Electric Bicycle, Electric Scooter, Electric Skateboard, Electrically motorized Board, or other device propelled by an electric motor and designed to transport 1 or more persons, as defined in the California Vehicle Code.
ELECTRIC BICYCLE. An electric bicycle, or " E-Bike", which is a bicycle equipped with fully operable pedals and an electric motor of less than 750 watts, and is categorized by the following, per California Vehicle Code section 312.5, as may be amended:
1) Class 1 - an electric bicycle equipped with a motor that provides assistance only when the rider is pedaling, and that ceases to provide assistance when the bicycle reaches a speed of 20 miles per hour.
2) Class 2 - an electric bicycle equipped with a motor that may be used exclusively to propel the bicycle, and that is not capable of providing assistance when the bicycle reaches a speed of 20 miles per hour.
556
3) Class 3 - an electric bicycle equipped with a motor that provides assistance only when the rider is pedaling, and that ceases to provide assistance when the bicycle reaches a speed of 28 miles per hour and is equipped with a speedometer.
ELECTRIC SCOOTER OR E-SCOOTER. A two or three -wheeled device that has handlebars, a floorboard that is designed to be stood on while riding and is powered by an electric motor. This device may also have a driver seat that does not interfere with the ability of the rider to stand and ride, and may also be designed to be powered by human propulsion.
ELECTRIC SKATEBOARD OR E-SKATEBOARD. An up to four-wheeled device that has a floorboard that is designed to be stood on while riding and is powered by an electric motor.
ELECTRICALLY MOTORIZED BOARD. Has the same meaning as set forth in California Vehicle Code section 313.5, as that section may be amended.
HIGHWAY. A way or place of whatever nature, publicly maintained and open to the use of the public for purposes of vehicular travel. Highway includes street.
MOTORIZED BICYCLE. Any two -wheeled or three -wheeled device having fully operative pedals for propulsion by human power or having no pedals if powered solely by electrical energy, has an automatic transmission, and a motor which produces less than four gross brake horsepower and is capable of propelling the device at a maximum speed of not more than 30 miles per hour on level ground, per California Vehicle Code section 406, as may be amended. § 10.56.190 ENFORCEMENT.
A) Parental responsibility. The parent of any child and the guardian of any ward shall not authorize or knowingly permit any minor child or ward to violate any of the provisions of this Chapter.
B) Penalty for violations. Every person violating any provisions of this Chapter shall be subject to the penalties provided for in Chapter 1.16 of the Wildomar Municipal Code.
C) Infraction, Fines, and Penalties. Any person who violates this chapter is guilty of an infraction and punishable by a fine as set forth in Chapter 1.16 of the Wildomar Municipal Code. This chapter may also be enforced via administrative or civil actions as authorized by Chapter 1.16 of the Wildomar Municipal Code.
D) An electric bike shall meet the following criteria consistent with California Vehicle Code sections 312.5 and 24016, as those sections may be amended:
1) Comply with the equipment and manufacturing requirements for bicycles adopted by the United States Consumer Product Safety Commission (16 C. F. R. 1512. 1, et seq.). 2) Operate in a manner so that the electric motor is disengaged or ceases to function when the brakes are applied or operate in a manner such that the motor is engaged through a switch or mechanism that, when released or deactivated, will cause the electric motor to disengage or cease to function.
557
3) A person shall not tamper with or modify an electric bicycle so as to change the speed capability of the device, unless he or she appropriately replaces the label indicating the appropriate classification.
4) A device that has been modified so that it no longer meets the definition of an “electric bicycle” under California Vehicle Code section 312.5 is not considered an electric bicycle for purposes of this Chapter and must comply with any other applicable California law governing motorized devices
558
E-Bike and E-Conveyance Ordinance
City Council - March 11, 2026
Abdu Lachgar, AICP, Principal Planner
559
Over the last few years, the Region has experienced a rise in the number of E-Conveyances (E-Bikes, E-Scooters, and E-Skateboards) operating on streets and bike paths.
Common concerns include a lack of helmets, reckless speeds, inattention, carrying too many passengers, and the increased potential for collisions and major injury.
Staff thoroughly researched local regulations pertaining to EConveyances and contacted other neighboring jurisdictions as well Multiple jurisdictions throughout Southern California are in the process of implementing similar ordinances or have done so already. The proposed ordinance aims to improve public safety and address the risks associated with E-Conveyance use while remaining compliant with state law. 560
561
E-Motorcycle
562
SUMMARY OF CHAPTER
Adding a completely new Chapter 10.56 to Title 10 of the WMC, which introduces several key provisions to ensure safety including but not limited to:
Riders would be required to comply with all traffic laws and traffic-control devices.
Helmets would be mandatory for riders under the age of 18. E-Conveyances must also be equipped with essential safety features such as lights and reflectors.
Persons under the age of 16 would be prohibited from operating a Class 3 E-bike. Prohibits riding upon any playground, park, or school ground not specifically designated as a bicycle path or route, unless specifically posted. Parents of minors would be responsible for any fees or penalties associated with a violation.
Engaging in unsafe actions or reckless behavior would be strictly prohibited. 563
RECOMMENDATION
The Community Development Department recommends the
City Council take the following actions:
1) Determine that Ordinance No. _____, is exempt under the California Environmental Quality Act (CEQA) and CEQA
Guidelines, pursuant to the common-sense exemption, Section 15061(b)(3) of the CEQA Guidelines, under the general rule making provision.
2) Introduce and conduct the first reading by title only Ordinance No. _____
3) Direct the City Clerk to schedule the second reading of the Ordinance at the next regular City Council meeting or as soon thereafter as feasible. 564