Geotechnical Engineering Exploration and Analysis
Proposed 3-Story Public Storage Building
1330 East Cypress Street
Covina, California
Project No. 2G-2104006

Page 18 ends

_________________________________________________________________________ GILES ENGINEERING ASSOCIATES, INC.
low-expansive cohesive layer, or pavement, should be placed at the surface to help prevent surface water intrusion. A geotextile or filter fabric should be placed between the granular drainage layers and adjacent soils (excavated face or compacted materials) to prevent fines from migrating into the drainage layers.

Backfill should be placed in lifts not exceeding 8 inches in thickness, moisture conditioned to slightly above optimum moisture content, and mechanically compacted throughout to at least 90 percent of the maximum dry density as determined by Modified Proctor (ASTM D 1557). Retaining walls should be properly braced prior to placement and compaction of backfill should be performed with extreme care not to damage the walls.

6.7 New Pavement
The following recommendations for the new pavement (if needed) are intended for vehicular traffic associated with the hotel development within the subject property.

New Pavement Subgrades
Following completion of the recommended subgrade preparation procedures, the subgrade in areas of new pavement construction are expected to consist of existing on-site soil that exhibit a very low expansion potential and based on a USCS designation of SC. An R-value of 10 has been assumed in the preparation of the pavement design. It should however, be recognized that the City of Covina may require a specific R-value test to verify the use of the following design. It is recommended that this testing, if required, be conducted following completion of rough grading in the proposed pavement areas so that the R-value test results are indicative of the actual pavement subgrade soils.

Alternatively, a minimum code pavement section may be required if a specific R-value test is not performed. To use this R-value, all fill added to the pavement subgrade must have pavement support characteristics at least equivalent to the existing soils, and must be placed and compacted in accordance with the project specifications.

Asphalt Pavements
The following table presents recommended thicknesses for a new flexible pavement structure consisting of asphaltic concrete over a granular base, along with the appropriate CALTRANS specifications for proper materials and placement procedures. An alternate pavement section has been provided for use in parking stall areas due to the anticipated lower traffic intensity in these areas.

However, care must be used so that truck traffic is excluded from areas where the thinner pavement section is used, since premature pavement distress may occur. In the event that heavy vehicle traffic cannot be excluded from the specific areas, the pavement section recommended for drive lanes should be used throughout the parking lot.

Page 950 of 1828 ends

Geotechnical Engineering Exploration and Analysis
Proposed 3-Story Public Storage Building
1330 East Cypress Street
Covina, California
Project No. 2G-2104006

Page 19 ends

_________________________________________________________________________ GILES ENGINEERING ASSOCIATES, INC.

Pavement recommendations are based upon CALTRANS design parameters for a twenty-year design period and assume proper drainage and construction monitoring. It is, therefore, recommended that the geotechnical engineer monitors and tests subgrade preparation, and that the subgrade be evaluated immediately before pavement construction.

Portland Concrete Pavements
Portland Cement Concrete pavements are recommended in areas where traffic is concentrated such as the entrance/exit aprons as well as areas subjected to heavy loads such as the trash enclosure loading zone. The preparation of the subgrade soils within concrete pavement areas should be performed as previously described in this report. Portland Cement Concrete pavements in high stress areas are recommended to be at least 6 inches thick containing No. 3 bars at 18-inch on-center both ways placed at mid-height. The pavement should be constructed in accordance with Section 40 of the CALTRANS Standard Specifications. A minimum 4-inch thick layer of base course (CALTRANS Class 2) is recommended below the concrete pavement. This base course should be compacted to at least 95% of the material’s maximum dry density.

The maximum joint spacing within all of the Portland Cement Concrete pavements is recommended to be 15 feet to control shrinkage cracking. Load transfer reinforcing is recommended at construction joints perpendicular to traffic flow if construction joints are not properly keyed. In this event, ¾-inch diameter smooth dowel bars, 18 inches in length placed at 12 inches on-center are recommended where joints are perpendicular to the anticipated traffic flow. Expansion joints are recommended only where the pavement abuts fixed objects such as light standard foundations. Tie bars are recommended at the first joint within the perimeter of the concrete pavement area. Tie bars are recommended to be No. 4 bars at 42-inch on-center spacings and at least 48 inches in length.

ASPHALT PAVEMENTS
Materials Thickness (inches) CALTRANS
Parking Stalls Specifications
(TI=4.0)
Drive Lanes
(TI=5.0)
Asphaltic Concrete
Surface Course (b) 1 1 Section 39, (a)
Asphaltic Concrete
Binder Course (b) 2 2 Section 39, (a)
Crushed Aggregate
Base Course 6 9 Section 26, Class 2 (R-value at least 78) NOTES:
(a) Compaction to density between 95 and 100 percent of the 50-Blow Marshall Density (b) The surface and binder course may be combined as a single layer placed in one lift if similar materials are utilized.

Page 951 of 1828 ends

Geotechnical Engineering Exploration and Analysis
Proposed 3-Story Public Storage Building
1330 East Cypress Street
Covina, California
Project No. 2G-2104006

Page 20 ends

_________________________________________________________________________ GILES ENGINEERING ASSOCIATES, INC.

General Considerations
Pavement recommendations assume proper drainage and construction monitoring and are based on traffic loads as indicated previously. Pavement designs are based on either PCA or CALTRANS design parameters for twenty (20) year design period. However, these designs are also based on a routine pavement maintenance program and significant asphalt concrete pavement rehabilitation after about 8 to 10 years, in order to obtain a reasonable pavement service life.

6.8 Recommended Construction Materials Testing Services The report was prepared assuming that Giles will perform Construction Materials Testing (CMT) services during construction of the proposed development. In general, CMT services are recommended (and expected) to at least include observation and testing of foundation and pavement support soil and other construction materials. It might be necessary for Giles to provide supplemental geotechnical recommendations based on the results of CMT services and specific details of the project not known at this time.

6.9 Basis of Report
This report is based on Giles’ proposal, which is dated April 22, 2021 and is referenced by Giles’ proposal number 2GP-2104006. The actual services for the project varied somewhat from those described in the proposal because of the conditions that were encountered while performing the services and in consideration of the proposed project.

This report is strictly based on the project description given earlier in this report. Giles must be notified if any parts of the project description or our assumptions are not accurate so that this report can be amended, if needed. This report is based on the assumption that the facility will be designed and constructed according to the codes that govern construction at the site.

The conclusions and recommendations in this report are based on estimated subsurface conditions as shown on the Records of Subsurface Exploration. Giles must be notified if the subsurface conditions that are encountered during construction of the proposed development differ from those shown on the Records of Subsurface Exploration because this report will likely need to be revised.

General comments and limitations of this report are given in the appendix. © Giles Engineering Associates, Inc. 2021

Page 952 of 1828 ends

APPENDIX A

FIGURES AND TEST BORING LOGS
The Test Boring Location Plan contained herein was prepared based upon information supplied by Giles’ client, or others, along with Giles’ field measurements and observations. The diagram is presented for conceptual purposes only and is intended to assist the reader in report interpretation.

The Test Boring Logs and related information enclosed herein depict the subsurface (soil and water) conditions encountered at the specific boring locations on the date that the exploration was performed. Subsurface conditions may differ between boring locations and within areas of the site that were not explored with test borings. The subsurface conditions may also change at the boring locations over the passage of time.

Page 953 of 1828 ends

PROPOSED CURBING PROPOSED BUILDING ELEVATOR ELEVATOR STAIRS STAIRS N. GLENDORA AVE.
(2nd FLOOR F.F. = 0.0' = 76.0')
(1st FLOOR F.F. = -10.0' = 66.0')
(NO BASEMENT) PROPOSED ENCLOSURE DATE CAD No. 07-28-21 2G-2104006 TEST BORING LOCATION PLAN PROJECT NO.: COVINA, CALIFORNIA DESIGNED JLM PROPOSED PUBLIC STORAGE FIGURE 1 DRAWN SCALE approx. 1"=50' REVISED 2g2104006-blp -- 1330 E. CYPRESS STREET 0 25' 50' APPROXIMATE SCALE 1965 N. MAIN STREET ORANGE, CA 92865 (714)279-0817 NOTES: 1.) TEST BORING LOCATIONS ARE APPROXIMATE. 2.) BASE MAP DEVELOPED FROM THE "ATLA/NSPS LAND CRC ENGINEERING, INC. TITLE SURVEY", DATED 5-7-2021, PREPARED BY ILES NGINEERING SSOCIATES, INC. www.gilesengr.com

3.) PROPOSED FEATURES ARE APPROXIMATE BASED ON THE PREPARED BY KSP STUDIO. "CONCEPTUAL SITE PLAN" (SHEET 2), DATED 5-19-2021, LEGEND: GEOTECHNICAL TEST BORING PERCOLATION TEST BORING GEOTECHNICAL TEST BORING /

Page 954 of 1828 ends

Approximately 3 inches of asphaltic concrete
over 5 inches of aggregate base
Brown Silty fine Sand, trace Gravel - Moist
(Possible Fill)
Light Brown Gravelly fine to medium Sand -
Damp
Light Brown Gravelly fine to medium Sand -
Damp (Possible Cobbles and Boulders)
Boring Terminated at about 26.5 feet (EL.
643.5')
1-SS
2-SS
3-SS
4-SS
5-SS
6-SS
7-SS
EI=11
Very low bulk
sample (0-12
feet)
3 10
38 27
50/5"
35 63
8 4
2 2
3 3
3 Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-1 TEST BORING LOG
670 feet
05/11/21
Depth (ft)
5 10
15 20
25 Elevation
665
660
655
650
645

MATERIAL DESCRIPTION
SampleNo. & Type
SS = Standard Penetration Test
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 955 of 1828 ends

Approximately 3 inches of asphaltic concrete
over 6 inches of aggregate base
Brown Gravelly Sand and Silt - Moist (Fill)
Light Brown Silty Sand with Gravel - Dry
Brown Silty fine Sand with Gravel - Dry
(Possible Cobbles and Boulders)
Brown Silty fine Sand with Cobbles and
Gravel - Dry
Light Brown Gravel with Cobbles and
Possible Boulders - Damp
Boring Terminated at about 26.5 feet (EL.
644.5')
1-SS
2-SS
3-SS
4-SS
5-SS
6-SS
7-SS
6 25
28 33
50/6"
57 50/6"
8 2
2 1
3 2
1 Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-2 TEST BORING LOG
671 feet
05/11/21
Depth (ft)
10 20 Elevation
670
660
650

MATERIAL DESCRIPTION
SampleNo. & Type
SS = Standard Penetration Test
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 956 of 1828 ends

Approximately 3 inches of asphaltic concrete
over 5 inches of aggregate base
Brown Silty fine Sand, trace Clay - Moist (Fill)
Brown Silty fine Sand, trace Gravel - Moist
Brown coarse Sand with Gravel - Dry
Brown Silty fine Sand, trace Gravel - Moist
Boring Terminated at about 26.5 feet (EL.
642.5')
1-SS
2-SS
3-SS
4-SS
5-SS
6-SS
7-SS
5 6
7 9
55 57
24 19
6 6
12 3
1 13
Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-3 TEST BORING LOG
669 feet
05/11/21
Depth (ft)
5 10
15 20
25 Elevation
665
660
655
650
645

MATERIAL DESCRIPTION
SampleNo. & Type
SS = Standard Penetration Test
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 957 of 1828 ends

Approximately 3 inches of asphaltic concrete
over 5 inches of aggregate base
Brown Silty fine Sand coarse Gravel - Moist
(Fill)
Brown Silty fine to medium Sand, trace
Gravel - Moist
Light Brown coarse fine to medium Sand with
Gravel - Dry
Brown Silty fine Sand with Gravel and
Cobbles - Dry
Boring Terminated at about 26.5 feet (EL.
641.5')
1-SS
2-CS
3-CS
4-SS
5-SS
6-SS
7-SS
4 14
36 46
85 29
50/3"
6 3
1 1
1 3
Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-4/P-2 TEST BORING LOG
668 feet
05/11/21
Depth (ft)
10 20 Elevation
660
650

MATERIAL DESCRIPTION
SampleNo. & Type
CS = California Split Spoon
SS = Standard Penetration Test
Note: Percolation test performed at 5 feet below grade at a distance of about 5 feet from 0-4
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 958 of 1828 ends

Approximately 2 inches of asphaltic concrete
over 3 inches of aggregate base
Brown fine Sandy Silt, trace Gravel - Moist
(Fill)
Brown fine Sandy Silt, trace Gravel - Moist
(Possible Fill)
Brown Silty fine to medum Sand, trace
Gravel - Dry
Brown Silty fine Sand, trace Gravel - Moist
Brown coarse Sand with Gravel - Dry
Brown Silty fine Sand with Gravel - Moist
Boring Terminated at about 26.5 feet (EL.
639.5')
1-SS
2-SS
3-SS
4-SS
5-SS
6-SS
7-SS
5 5
12 10
44 27
46 8
11 1
5 1
2 1
Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-5 TEST BORING LOG
666 feet
05/11/21
Depth (ft)
5 10
15 20
25 Elevation
665
660
655
650
645
640

MATERIAL DESCRIPTION
SampleNo. & Type
SS = Standard Penetration Test
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 959 of 1828 ends

Approximately 2 inches of asphaltic concrete
over 3 inches of aggregate base
Brown Silty fine Sand - Damp (Possible Fill)
Brown Silty fine Sand, trace Gravel - Moist
Brown Silty fine Sand, trace Gravel - Dry
Light Brown Gravelly fine to coarse Sand -
Damp
Light Brown Silty fine Sand with Gravel - Dry
Brown Silty fine to medium Sand - Moist
Brown Silty fine Sand, trace Gravel - Dry
Boring Terminated at about 36.5 feet (EL.
627.5')
1-SS
2-SS
3-SS
4-SS
5-SS
6-SS
7-SS
8-SS
9-SS
5 6
13 15
40 24
57 47
61 2
5 18
2 3
1 2
1 1
Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-6 TEST BORING LOG
664 feet
05/11/21
Depth (ft)
10 20
30 Elevation
660
650
640
630

MATERIAL DESCRIPTION
SampleNo. & Type
SS = Standard Penetration Test
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 960 of 1828 ends

Approximately 4 inches of asphaltic concrete
over 4 inches of aggregate base
Brown Silty fine Sand, trace Gravel - Moist
(Fill)
Brown Silty fine Sand, trace Gravel - Moist
Light Brown Silty fine Sand with Gravel - Dry
Light Brown coarse Sand and Gravel - Dry
(Possible Cobbles and Boulders)
Boring Terminated at about 26.5 feet (EL.
639.5')
1-SS
2-SS
3-SS
4-SS
5-SS
6-SS
7-SS
6 4
19 24
75 50/5"
61 5
3 2
2 2
2 4
Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-7 TEST BORING LOG
666 feet
05/11/21
Depth (ft)
5 10
15 20
25 Elevation
665
660
655
650
645
640

MATERIAL DESCRIPTION
SampleNo. & Type
SS = Standard Penetration Test
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 961 of 1828 ends

Approximately 3 inches of asphaltic concrete
over 3 inches of aggregate base
Brown Silty fine Sand, with Gravel - Moist
(Fill)
Light Brown Silty fine to coarse Sand with
Gravel - Dry (Possible Cobbles and
Boulders)
Brown Silty fine Sand, trace Gravel - Damp
Brown Silty fine Sand with Gravel - Moist
Brown Silty fine Sand with Gravel and
Cobbles - Dry
Boring Terminated at about 36.5 feet (EL.
632.5')
1-SS
2-CS
3-CS
4-SS
5-SS
6-SS
7-SS
8-SS
9-SS
5 19
43 39
81 50/6"
37 44
50/4"
5 5
4 2
3 3
1 5
3 Water Observation Data

GILES ENGINEERING
ASSOCIATES, INC.

Remarks:

B-8/P-1 TEST BORING LOG
669 feet
05/11/21
Depth (ft)
10 20
30 Elevation
660
650
640

MATERIAL DESCRIPTION
SampleNo. & Type
CS = California Split Spoon
SS = Standard Penetration Test
Note: Percolation test performed at 5 feet below grade at a distance of about 5 feet from 0-4
PROJECT NO: 2G-2104006

PROPOSED PUBLIC STORAGE FACILITY
Changes in strata indicated by the lines are approximate boundary between soil types. The actual transition may be gradual and may vary considerably between test borings. Location of test boring is shown on the Boring Location Plan.

BORING NO. & LOCATION:

Water Level At End of Drilling:

Water Level After Drilling:

FIELD REP:

NOTES

ROBERT TORRES
N
1330 E. CYPRESS STREET

COVINA, CA
Qu
(tsf)
Qp
(tsf)
Qs
(tsf)
W
(%)
PID
SURFACE ELEVATION:

COMPLETION DATE:

Water Encountered During Drilling: None
Cave Depth At End of Drilling:

Cave Depth After Drilling: GILES LOG REPORT 2G-2104006.GPJ GILES.GDT 7/30/21

Page 962 of 1828 ends

APPENDIX B

FIELD PROCEDURES
The field operations were conducted in general accordance with the procedures recommended by the American Society for Testing and Materials (ASTM) designation D 420 entitled “Standard Guide for Sampling Rock and Rock” and/or other relevant specifications.

Soil samples were preserved and transported to Giles’ laboratory in general accordance with the procedures recommended by ASTM designation D 4220 entitled “Standard Practice for Preserving and Transporting Soil Samples.” Brief descriptions of the sampling, testing and field procedures commonly performed by Giles are provided herein.

Page 963 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

GENERAL FIELD PROCEDURES
Test Boring Elevations
The ground surface elevations reported on the Test Boring Logs are referenced to the assumed benchmark shown on the Boring Location Plan (Figure 1). Unless otherwise noted, the elevations were determined with a conventional hand-level and are accurate to within about 1 foot.

Test Boring Locations
The test borings were located on-site based on the existing site features and/or apparent property lines. Dimensions illustrating the approximate boring locations are reported on the Boring Location Plan (Figure 1).

Water Level Measurement
The water levels reported on the Test Boring Logs represent the depth of “free” water encountered during drilling and/or after the drilling tools were removed from the borehole. Water levels measured within a granular (sand and gravel) soil profile are typically indicative of the water table elevation. It is usually not possible to accurately identify the water table elevation with cohesive (clayey) soils, since the rate of seepage is slow. The water table elevation within cohesive soils must therefore be determined over a period of time with groundwater observation wells.

It must be recognized that the water table may fluctuate seasonally and during periods of heavy precipitation. Depending on the subsurface conditions, water may also become perched above the water table, especially during wet periods.

Borehole Backfilling Procedures
Each borehole was backfilled upon completion of the field operations. If potential contamination was encountered, and/or if required by state or local regulations, boreholes were backfilled with an “impervious” material (such as bentonite slurry).

Borings that penetrated pavements, sidewalks, etc. were “capped” with Portland Cement concrete, asphaltic concrete, or a similar surface material. It must, however, be recognized that the backfill material may settle, and the surface cap may subside, over a period of time. Further backfilling and/or re-surfacing by Giles’ client or the property owner may be required.

Page 964 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

FIELD SAMPLING AND TESTING PROCEDURES
Auger Sampling (AU)
Soil samples are removed from the auger flights as an auger is withdrawn above the ground surface. Such samples are used to determine general soil types and identify approximate soil stratifications. Auger samples are highly disturbed and are therefore not typically used for geotechnical strength testing.

Split-Barrel Sampling (SS) – (ASTM D-1586)
A split-barrel sampler with a 2-inch outside diameter is driven into the subsoil with a 140- pound hammer free-falling a vertical distance of 30 inches. The summation of hammerblows required to drive the sampler the final 12-inches of an 18-inch sample interval is defined as the “Standard Penetration Resistance” or N-value is an index of the relative density of granular soils and the comparative consistency of cohesive soils. A soil sample is collected from each SPT interval.

Shelby Tube Sampling (ST) – (ASTM D-1587)
A relatively undisturbed soil sample is collected by hydraulically advancing a thin-walled Shelby Tube sampler into a soil mass. Shelby Tubes have a sharp cutting edge and are commonly 2 to 5 inches in diameter.

Bulk Sample (BS)
A relatively large volume of soils is collected with a shovel or other manually-operated tool. The sample is typically transported to Giles’ materials laboratory in a sealed bag or bucket.

Dynamic Cone Penetration Test (DC) – (ASTM STP 399)
This test is conducted by driving a 1.5-inch-diameter cone into the subsoil using a 15- pound steel ring (hammer), free-falling a vertical distance of 20 inches. The number of hammer-blows required to drive the cone 1¾ inches is an indication of the soil strength and density, and is defined as “N”. The Dynamic Cone Penetration test is commonly conducted in hand auger borings, test pits and within excavated trenches. - Continued -

Page 965 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

Ring-Lined Barrel Sampling – (ASTM D 3550)
In this procedure, a ring-lined barrel sampler is used to collect soil samples for classification and laboratory testing. This method provides samples that fit directly into laboratory test instruments without additional handling/disturbance.

Sampling and Testing Procedures
The field testing and sampling operations were conducted in general accordance with the procedures recommended by the American Society for Testing and Materials (ASTM) and/or other relevant specifications. Results of the field testing (i.e. N-values) are reported on the Test Boring Logs. Explanations of the terms and symbols shown on the logs are provided on the appendix enclosure entitled “General Notes”.

Page 966 of 1828 ends

APPENDIX C

LABORATORY TESTING AND CLASSIFICATION
The laboratory testing was conducted under the supervision of a geotechnical engineer in accordance with the procedures recommended by the American Society for Testing and Materials (ASTM) and/or other relevant specifications. Brief descriptions of laboratory tests commonly performed by Giles are provided herein.

Page 967 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

LABORATORY TESTING AND CLASSIFICATION
Photoionization Detector (PID)
In this procedure, soil samples are “scanned” in Giles’ analytical laboratory using a Photoionization Detector (PID). The instrument is equipped with an 11.7 eV lamp calibrated to a Benzene Standard and is capable of detecting a minute concentration of certain Volatile Organic Compound (VOC) vapors, such as those commonly associated with petroleum products and some solvents. Results of the PID analysis are expressed in HNu (manufacturer’s) units rather than actual concentration.

Moisture Content (w) (ASTM D 2216)
Moisture content is defined as the ratio of the weight of water contained within a soil sample to the weight of the dry solids within the sample. Moisture content is expressed as a percentage.

Unconfined Compressive Strength (qu) (ASTM D 2166)
An axial load is applied at a uniform rate to a cylindrical soil sample. The unconfined compressive strength is the maximum stress obtained or the stress when 15% axial strain is reached, whichever occurs first.

Calibrated Penetrometer Resistance (qp)
The small, cylindrical tip of a hand-held penetrometer is pressed into a soil sample to a prescribed depth to measure the soils capacity to resist penetration. This test is used to evaluate unconfined compressive strength.

Vane-Shear Strength (qs)
The blades of a vane are inserted into the flat surface of a soil sample and the vane is rotated until failure occurs. The maximum shear resistance measured immediately prior to failure is taken as the vane-shear strength.

Loss-on-Ignition (ASTM D 2974; Method C)
The Loss-on-Ignition (L.O.I.) test is used to determine the organic content of a soil sample. The procedure is conducted by heating a dry soil sample to 440°C in order to burn-off or “ash” organic matter present within the sample. The L.O.I. value is the ratio of the weight loss due to ignition compared to the initial weight of the dry sample. L.O.I. is expressed as a percentage.

Page 968 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

Particle Size Distribution (ASTB D 421, D 422, and D 1140) This test is performed to determine the distribution of specific particle sizes (diameters) within a soil sample. The distribution of coarse-grained soil particles (sand and gravel) is determined from a “sieve analysis,” which is conducted by passing the sample through a series of nested sieves. The distribution of fine-grained soil particles (silt and clay) is determined from a “hydrometer analysis” which is based on the sedimentation of particles suspended in water.

Consolidation Test (ASTM D 2435)
In this procedure, a series of cumulative vertical loads are applied to a small, laterally confined soil sample. During each load increment, vertical compression (consolidation) of the sample is measured over a period of time. Results of this test are used to estimate settlement and time rate of settlement.

Classification of Samples
Each soil sample was visually-manually classified, based on texture and plasticity, in general accordance with the Unified Soil Classification System (ASTM D-2488-75). The classifications are reported on the Test Boring Logs.

Laboratory Testing
The laboratory testing operations were conducted in general accordance with the procedures recommended by the American Society for Testing and Materials (ASTM) and/or other relevant specifications. Results of the laboratory tests are provided on the Test Boring Logs or other appendix enclosures. Explanation of the terms and symbols used on the logs is provided on the appendix enclosure entitled “General Notes.”

Page 969 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

California Bearing Ratio (CBR) Test ASTM D-1833
The CBR test is used for evaluation of a soil subgrade for pavement design. The test consists of measuring the force required for a 3-square-inch cylindrical piston to penetrate 0.1 or 0.2 inch into a compacted soil sample. The result is expressed as a percent of force required to penetrate a standard compacted crushed stone.

Unless a CBR test has been specifically requested by the client, the CBR is estimated from published charts, based on soil classification and strength characteristics. A typical correlation chart is below.

Page 970 of 1828 ends

APPENDIX D

GENERAL INFORMATION

Page 971 of 1828 ends
Page 972 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

GENERAL COMMENTS
The soil samples obtained during the subsurface exploration will be retained for a period of thirty days. If no instructions are received, they will be disposed of at that time.

This report has been prepared exclusively for the client in order to aid in the evaluation of this property and to assist the architects and engineers in the design and preparation of the project plans and specifications. Copies of this report may be provided to contractor(s), with contract documents, to disclose information relative to this project.

The report, however, has not been prepared to serve as the plans and specifications for actual construction without the appropriate interpretation by the project architect, structural engineer, and/or civil engineer. Reproduction and distribution of this report must be authorized by the client and Giles.

This report has been based on assumed conditions/characteristics of the proposed development where specific information was not available. It is recommended that the architect, civil engineer and structural engineer along with any other design professionals involved in this project carefully review these assumptions to ensure they are consistent with the actual planned development. When discrepancies exist, they should be brought to our attention to ensure they do not affect the conclusions and recommendations provided herein. The project plans and specifications may also be submitted to Giles for review to ensure that the geotechnical related conclusions and recommendations provided herein have been correctly interpreted.

The analysis of this site was based on a subsoil profile interpolated from a limited subsurface exploration. If the actual conditions encountered during construction vary from those indicated by the borings, Giles must be contacted immediately to determine if the conditions alter the recommendations contained herein.

The conclusions and recommendations presented in this report have been promulgated in accordance with generally accepted professional engineering practices in the field of geotechnical engineering. No other warranty is either expressed or implied.

Page 973 of 1828 ends

With Dust
Palliative
With
Bituminous
Treatment
GW Good: tractor, rubber-tired, steel
wheel or vibratory roller
125-135 Almost none Good drainage,
pervious
Very stable Excellent Good Fair to
poor
Excellent
GP Good: tractor, rubber-tired, steel
wheel or vibratory roller
115-125 Almost none Good drainage,
pervious
Reasonably stable
Excellent to
good
Poor to fair Poor
GM Good: rubber-tired or light
sheepsfoot roller
120-135 Slight Poor drainage,
semipervious
Reasonably stable
Excellent to
good
Fair to poor Poor Poor to fair
GC Good to fair: rubber-tired or
sheepsfoot roller
115-130 Slight Poor drainage,
impervious
Reasonably stable
Good Good to fair
**
Excellent Excellent
SW Good: tractor, rubber-tired or
vibratory roller
110-130 Almost none Good drainage,
pervious
Very stable Good Fair to poor Fair to
poor
Good
SP Good: tractor, rubber-tired or
vibratory roller
100-120 Almost none Good drainage,
pervious
Reasonably stable when dense
Good to fair Poor Poor Poor to fair
SM Good: rubber-tired or sheepsfoot
roller
110-125 Slight Poor drainage,
impervious
Reasonably stable when dense
Good to fair Poor Poor Poor to fair
SC Good to fair: rubber-tired or
sheepsfoot roller
105-125 Slight to
mediu
m
Poor drainage, impervious
Reasonably stable
Good to fair Fair to poor Excellent Excellent
ML Good to poor: rubber-tired or
sheepsfoot roller
95-120 Slight to
medium
Poor drainage, impervious
Poor stability, high density required
Fair to poor Not suitable Poor Poor
CL Good to fair: sheepsfoot or rubbertired roller 95-120 Medium No drainage, impervious Good stability Fair to poor Not suitable Poor Poor OL Fair to poor: sheepsfoot or rubbertired roller 80-100 Medium to high Poor drainage, impervious Unstable, should not be used Poor Not suitable Not suitable Not suitable MH Fair to poor: sheepsfoot or rubbertired roller 70-95 High Poor drainage, impervious Poor stability, should not be used
Poor Not suitable Very poor Not suitable
CH Fair to poor: sheepsfoot roller 80-105 Very high No drainage, impervious
Fair stability, may soften on expansion
Poor to very poor
Not suitable Very poor Not suitable
OH Fair to poor: sheepsfoot roller 65-100 High No drainage, impervious
Unstable, should not be used
Very poor Not suitable Not
suitable
Not suitable
Pt Not suitable Very high Fair to poor
drainage
Should not be used
Not suitable Not suitable Not
suitable
Not suitable
* "The Unified Classification: Appendix A - Characteristics of Soil, Groups Pertaining to Roads and Airfields, and Appendix B - Characteristics of Soil Groups Pertaining to Embankments and Foundations," Technical Memorandum 357, U.S. Waterways Ixperiment Station, Vicksburg, 1953.** Not suitable if subject to frost.

GILES ENGINEERING ASSOCIATES, INC.

CHARACTERISTICS AND RATINGS OF UNIFIED SOIL SYSTEM CLASSES FOR SOIL CONSTRUCTION * Value as Temporary
Pavement
Class Compaction Characteristics
Max. Dry
Density
Standard
Proctor
(pcf)
Compressibility
and Expansion
Drainage and
Permeability
Value as an
Embankment
Material
Value as
Subgrade
When Not
Subject to
Frost
Value as Base
Course

Page 974 of 1828 ends

Giles Engineering Associates, Inc.

UNIFIED SOIL CLASSIFICATION SYSTEM (ASTM D-2487)
Major Divisions Group
Symbols Typical Names Laboratory Classifi cation Criteria Coarse-grained soils
(more than half of material is larger than No. 200 sieve size) Gravels
(More than half of coarse fraction is larger
than No. 4 sieve size)
Clean gravels
(little or no
fi nes)
GW
Well-graded gravels,
gravel-sand mixtures,
little or no fi nes
Determine percentages of sand and gravel from grain-size curve.

Depending on percentage of fi nes (fraction smaller than No. 200 sieve size), coarsegrained soils are classifi ed as follows:

Less than 5 percent: GW, GP, SW, SP More than 12 percent: GM, GC, SM, SC 5 to 12 percent: Borderline cases requiring dual symbolsb Cu = greater than 4; Cc = between 1 and 3
GP
Poorly graded gravels,
gravel-sand mixtrues,
little or no fi nes
Not meeting all gradation requirements for GW
Gravels with fi nes
(appreciable amount of
fi nes)
GMa
d
Silty gravels, gravelsand-silt mixtures
Atterberg limits
below “A” line or P.I.
less than 4
Limits plotting within shaded
area, above “A” line with P.I.
between 4 and 7 are
borderline cases requiring
use of dual symbols
u
GC Clayey gravels, gravelsand-clay mixtures
Atterberg limits
above “A” line or P.I.
greater than 7
Sands
(More than half of coarse fraction is
smaller than No. 4 sieve size)
Clean sands
(Little or no
fi nes)
SW
Well-graded sands,
gravelly sands, little or
no fi nes
Cu = greater than 4; Cc = between 1 and 3
SP
Poorly graded sands,
gravelly sands, little or
no fi nes
Not meeting all gradation requirements for SW
Sands with fi nes
(Appreciable amount
of fi nes)
SMa
d
Silty sands, sand-silt
mixtures
Atterberg limits
below “A” line or P.I.
less than 4
Limits plotting within shaded
area, above “A” line with P.I.
between 4 and 7 are
borderline cases requiring
use of dual symbols
u
SC Clayey sands, sand-clay
mixtures
Atterberg limits
above “A” line or P.I.
greater than 7
Fine-grained soils
(More than half material is smaller than No. 200 sieve size) Silts and clays
(Liquid limit less than 50)
ML
Inorganic silts and
very fi ne sands, rock
fl our, silty or clayey fi ne
sands, or clayey silts
with slight plasticity
CL
Inorganic clays of low
to medium plasticity,
gravelly clays, sandy
clays, silty clays
OL
Organic silts and
organic silty clays of
low plasticity
Silts and clays
(Liquid limit greater than 50)
MH
Inorganic silts, micaceous or diatomaceous
fi ne sandy or silty soils,
elastic silts
CH Inorganic clays of high
plasticity, fat clays
OH
Organic clays of
medium to high
plasticity, organic silts
Highly
organic
soils
Pt Peat and other highly
organic soils
D = greater than 4; C 60
D10
(D = between 1 and 3 30)
2 D10 x D60
D60 = greater than 4; C D10
(D = between 1 and 3 30)
2 D10 x D60
Plasticity Chart
Plasticity Index
0 10 20 30 40 50 60 70 80 90 100 0
10 50
60 40
20 30
CH
OH and MH
CL
ML and OL
CL-ML
“A” line
Liquid Limit
a Division of GM and SM groups into subdivisions of d and u are for roads and airfi elds only. Subdivision is based on Atterberg limits, suffi x d used when L.L. is 28 or less and the P.I. is 6 or less; the suffi x u is used when L.L. is greater than 28. b Borderline classifi cations, used for soils possessing characteristics of two groups, are designated by combinations of group sympols. For example GW-GC, well-graded gravel-sand mixture with clay binder.

Page 975 of 1828 ends

GILES ENGINEERING ASSOCIATES, INC.

GENERAL NOTES

SAMPLE IDENTIFICATION
All samples are visually classified in general accordance with the Unified Soil Classification System (ASTM D-2487-75 or D-2488-75) DESCRIPTIVE TERM (% BY DRY WEIGHT) PARTICLE SIZE (DIAMETER) Trace: 1-10% Boulders: 8 inch and larger
Little: 11-20% Cobbles: 3 inch to 8 inch
Some: 21-35% Gravel: coarse - ¾ to 3 inch
And/Adjective 36-50% fine – No. 4 (4.76 mm) to ¾ inch
Sand: coarse – No. 4 (4.76 mm) to No. 10 (2.0 mm)
medium – No. 10 (2.0 mm) to No. 40 (0.42 mm)
fine – No. 40 (0.42 mm) to No. 200 (0.074 mm)
Silt: No. 200 (0.074 mm) and smaller (non-plastic)
Clay: No 200 (0.074 mm) and smaller (plastic)

SOIL PROPERTY SYMBOLS DRILLING AND SAMPLING SYMBOLS
Dd: Dry Density (pcf) SS: Split-Spoon
LL: Liquid Limit, percent ST: Shelby Tube – 3 inch O.D. (except where noted) PL: Plastic Limit, percent CS: 3 inch O.D. California Ring Sampler PI: Plasticity Index (LL-PL) DC: Dynamic Cone Penetrometer per ASTM LOI: Loss on Ignition, percent Special Technical Publication No. 399 Gs: Specific Gravity AU: Auger Sample
K: Coefficient of Permeability DB: Diamond Bit
w: Moisture content, percent CB: Carbide Bit
qp: Calibrated Penetrometer Resistance, tsf WS: Wash Sample qs: Vane-Shear Strength, tsf RB: Rock-Roller Bit
qu: Unconfined Compressive Strength, tsf BS: Bulk Sample qc: Static Cone Penetrometer Resistance Note: Depth intervals for sampling shown on Record of (correlated to Unconfined Compressive Strength, tsf) Subsurface Exploration are not indicative of sample PID: Results of vapor analysis conducted on representative recovery, but position where sampling initiated samples utilizing a Photoionization Detector calibrated to a benzene standard. Results expressed in HNU-Units. (BDL=Below Detection Limit) N: Penetration Resistance per 12 inch interval, or fraction thereof, for a standard 2 inch O.D. (1⅜ inch I.D.) split spoon sampler driven with a 140 pound weight free-falling 30 inches. Performed in general accordance with Standard Penetration Test Specifications (ASTM D1586). N in blows per foot equals sum of N-Values where plus sign (+) is shown.

Nc: Penetration Resistance per 1¾ inches of Dynamic Cone Penetrometer. Approximately equivalent to Standard Penetration Test N-Value in blows per foot.

Nr: Penetration Resistance per 12 inch interval, or fraction thereof, for California Ring Sampler driven with a 140 pound weight free-falling 30 inches per ASTM D-3550. Not equivalent to Standard Penetration Test N-Value.

SOIL STRENGTH CHARACTERISTICS

COHESIVE (CLAYEY) SOILS NON-COHESIVE (GRANULAR) SOILS

UNCONFINED

COMPARATIVE BLOWS PER COMPRESSIVE RELATIVE BLOWS PER

CONSISTENCY FOOT (N) STRENGTH (TSF) DENSITY FOOT (N)
Very Soft 0 - 2 0 - 0.25 Very Loose 0 - 4
Soft 3 - 4 0.25 - 0.50 Loose 5 - 10
Medium Stiff 5 – 8 0.50 - 1.00 Firm 11 - 30
Stiff 9 – 15 1.00 - 2.00 Dense 31 - 50
Very Stiff 16 – 30 2.00 - 4.00 Very Dense 51+
Hard 31+ 4.00+

DEGREE OF

DEGREE OF EXPANSIVE

PLASTICITY PI POTENTIAL PI
None to Slight 0 - 4 Low 0 - 15
Slight 5 - 10 Medium 15 - 25
Medium 11 - 30 High 25+
High to Very High 31+

Page 976 of 1828 ends

Geotechnical-Engineering Report
Important Information about This
Subsurface problems are a principal cause of construction delays, cost overruns, claims, and disputes.

While you cannot eliminate all such risks, you can manage them. The following information is provided to help.

The Geoprofessional Business Association (GBA)
has prepared this advisory to help you – assumedly
a client representative – interpret and apply this
geotechnical-engineering report as effectively as
possible. In that way, you can benefit from a lowered
exposure to problems associated with subsurface
conditions at project sites and development of
them that, for decades, have been a principal cause
of construction delays, cost overruns, claims,
and disputes. If you have questions or want more
information about any of the issues discussed herein,
contact your GBA-member geotechnical engineer.

Active engagement in GBA exposes geotechnical
engineers to a wide array of risk-confrontation
techniques that can be of genuine benefit for
everyone involved with a construction project.

Understand the Geotechnical-Engineering Services
Provided for this Report
Geotechnical-engineering services typically include the planning, collection, interpretation, and analysis of exploratory data from widely spaced borings and/or test pits. Field data are combined with results from laboratory tests of soil and rock samples obtained from field exploration (if applicable), observations made during site reconnaissance, and historical information to form one or more models of the expected subsurface conditions beneath the site. Local geology and alterations of the site surface and subsurface by previous and proposed construction are also important considerations. Geotechnical engineers apply their engineering training, experience, and judgment to adapt the requirements of the prospective project to the subsurface model(s). Estimates are made of the subsurface conditions that will likely be exposed during construction as well as the expected performance of foundations and other structures being planned and/or affected by construction activities.

The culmination of these geotechnical-engineering services is typically a geotechnical-engineering report providing the data obtained, a discussion of the subsurface model(s), the engineering and geologic engineering assessments and analyses made, and the recommendations developed to satisfy the given requirements of the project. These reports may be titled investigations, explorations, studies, assessments, or evaluations.

Regardless of the title used, the geotechnical-engineering report is an engineering interpretation of the subsurface conditions within the context of the project and does not represent a close examination, systematic inquiry, or thorough investigation of all site and subsurface conditions.

Geotechnical-Engineering Services are Performed
for Specific Purposes, Persons, and Projects,
and At Specific Times
Geotechnical engineers structure their services to meet the specific needs, goals, and risk management preferences of their clients. A geotechnical-engineering study conducted for a given civil engineer will not likely meet the needs of a civil-works constructor or even a different civil engineer. Because each geotechnical-engineering study is unique, each geotechnical-engineering report is unique, prepared solely for the client.

Likewise, geotechnical-engineering services are performed for a specific project and purpose. For example, it is unlikely that a geotechnicalengineering study for a refrigerated warehouse will be the same as one prepared for a parking garage; and a few borings drilled during a preliminary study to evaluate site feasibility will not be adequate to develop geotechnical design recommendations for the project.

Do not rely on this report if your geotechnical engineer prepared it:
• for a different client;
• for a different project or purpose;
• for a different site (that may or may not include all or a portion of the original site); or
• before important events occurred at the site or adjacent to it; e.g., man-made events like construction or environmental remediation, or natural events like floods, droughts, earthquakes, or groundwater fluctuations.

Note, too, the reliability of a geotechnical-engineering report can be affected by the passage of time, because of factors like changed subsurface conditions; new or modified codes, standards, or regulations; or new techniques or tools. If you are the least bit uncertain about the continued reliability of this report, contact your geotechnical engineer before applying the recommendations in it. A minor amount of additional testing or analysis after the passage of time – if any is required at all – could prevent major problems.

Read this Report in Full
Costly problems have occurred because those relying on a geotechnicalengineering report did not read the report in its entirety. Do not rely on an executive summary. Do not read selective elements only. Read and refer to the report in full.

You Need to Inform Your Geotechnical Engineer
About Change
Your geotechnical engineer considered unique, project-specific factors when developing the scope of study behind this report and developing the confirmation-dependent recommendations the report conveys.

Typical changes that could erode the reliability of this report include those that affect:
• the site’s size or shape;
• the elevation, configuration, location, orientation,
function or weight of the proposed structure and
the desired performance criteria;
• the composition of the design team; or
• project ownership.

As a general rule, always inform your geotechnical engineer of project or site changes – even minor ones – and request an assessment of their impact. The geotechnical engineer who prepared this report cannot accept

Page 977 of 1828 ends

responsibility or liability for problems that arise because the geotechnical engineer was not informed about developments the engineer otherwise would have considered.

Most of the “Findings” Related in This Report
Are Professional Opinions
Before construction begins, geotechnical engineers explore a site’s subsurface using various sampling and testing procedures. Geotechnical engineers can observe actual subsurface conditions only at those specific locations where sampling and testing is performed. The data derived from that sampling and testing were reviewed by your geotechnical engineer, who then applied professional judgement to form opinions about subsurface conditions throughout the site. Actual sitewide-subsurface conditions may differ – maybe significantly – from those indicated in this report. Confront that risk by retaining your geotechnical engineer to serve on the design team through project completion to obtain informed guidance quickly, whenever needed.

This Report’s Recommendations Are
Confirmation-Dependent
The recommendations included in this report – including any options or alternatives – are confirmation-dependent. In other words, they are not final, because the geotechnical engineer who developed them relied heavily on judgement and opinion to do so. Your geotechnical engineer can finalize the recommendations only after observing actual subsurface conditions exposed during construction. If through observation your geotechnical engineer confirms that the conditions assumed to exist actually do exist, the recommendations can be relied upon, assuming no other changes have occurred. The geotechnical engineer who prepared this report cannot assume responsibility or liability for confirmation-dependent recommendations if you fail to retain that engineer to perform construction observation.

This Report Could Be Misinterpreted
Other design professionals’ misinterpretation of geotechnicalengineering reports has resulted in costly problems. Confront that risk by having your geotechnical engineer serve as a continuing member of the design team, to:
• confer with other design-team members;
• help develop specifications;
• review pertinent elements of other design professionals’ plans and specifications; and
• be available whenever geotechnical-engineering guidance is needed.

You should also confront the risk of constructors misinterpreting this report. Do so by retaining your geotechnical engineer to participate in prebid and preconstruction conferences and to perform constructionphase observations.

Give Constructors a Complete Report and Guidance
Some owners and design professionals mistakenly believe they can shift unanticipated-subsurface-conditions liability to constructors by limiting the information they provide for bid preparation. To help prevent the costly, contentious problems this practice has caused, include the complete geotechnical-engineering report, along with any attachments or appendices, with your contract documents, but be certain to note conspicuously that you’ve included the material for information purposes only. To avoid misunderstanding, you may also want to note that “informational purposes” means constructors have no right to rely on the interpretations, opinions, conclusions, or recommendations in the report. Be certain that constructors know they may learn about specific project requirements, including options selected from the report, only from the design drawings and specifications. Remind constructors that they may perform their own studies if they want to, and be sure to allow enough time to permit them to do so. Only then might you be in a position to give constructors the information available to you, while requiring them to at least share some of the financial responsibilities stemming from unanticipated conditions. Conducting prebid and preconstruction conferences can also be valuable in this respect.

Read Responsibility Provisions Closely
Some client representatives, design professionals, and constructors do not realize that geotechnical engineering is far less exact than other engineering disciplines. This happens in part because soil and rock on project sites are typically heterogeneous and not manufactured materials with well-defined engineering properties like steel and concrete. That lack of understanding has nurtured unrealistic expectations that have resulted in disappointments, delays, cost overruns, claims, and disputes.

To confront that risk, geotechnical engineers commonly include explanatory provisions in their reports. Sometimes labeled “limitations,” many of these provisions indicate where geotechnical engineers’ responsibilities begin and end, to help others recognize their own responsibilities and risks. Read these provisions closely. Ask questions.

Your geotechnical engineer should respond fully and frankly.

Geoenvironmental Concerns Are Not Covered
The personnel, equipment, and techniques used to perform an environmental study – e.g., a “phase-one” or “phase-two” environmental site assessment – differ significantly from those used to perform a geotechnical-engineering study. For that reason, a geotechnical-engineering report does not usually provide environmental findings, conclusions, or recommendations; e.g., about the likelihood of encountering underground storage tanks or regulated contaminants. Unanticipated subsurface environmental problems have led to project failures. If you have not obtained your own environmental information about the project site, ask your geotechnical consultant for a recommendation on how to find environmental risk-management guidance.

Obtain Professional Assistance to Deal with
Moisture Infiltration and Mold
While your geotechnical engineer may have addressed groundwater, water infiltration, or similar issues in this report, the engineer’s services were not designed, conducted, or intended to prevent migration of moisture – including water vapor – from the soil through building slabs and walls and into the building interior, where it can cause mold growth and material-performance deficiencies.

Accordingly, proper implementation of the geotechnical engineer’s recommendations will not of itself be sufficient to prevent moisture infiltration. Confront the risk of moisture infiltration by including building-envelope or mold specialists on the design team.

Geotechnical engineers are not building-envelope or mold specialists.

Copyright 2019 by Geoprofessional Business Association (GBA). Duplication, reproduction, or copying of this document, in whole or in part, by any means whatsoever, is strictly prohibited, except with GBA’s specific written permission. Excerpting, quoting, or otherwise extracting wording from this document is permitted only with the express written permission of GBA, and only for purposes of scholarly research or book review. Only members of GBA may use this document or its wording as a complement to or as an element of a report of any kind.

Any other firm, individual, or other entity that so uses this document without being a GBA member could be committing negligent or intentional (fraudulent) misrepresentation.

Telephone: 301/565-2733
e-mail: [email protected] www.geoprofessional.org

Page 978 of 1828 ends
Page 979 of 1828 ends

Appendix D
Paleontological Resources
Assessment

Page 980 of 1828 ends
Page 981 of 1828 ends
Page 982 of 1828 ends
Page 983 of 1828 ends
Page 984 of 1828 ends
Page 985 of 1828 ends

739422862.3
|

Page 986 of 1828 ends
Page 987 of 1828 ends

STATEMENT OF CONFIDENTIALITY
This report contains confidential paleontological resources location information and distribution of this report is restricted. Paleontological resources are nonrenewable, and their scientific, values can be significantly impaired by disturbance. To deter fossil hunting, and other activities that can damage paleontological resources, the locations of paleontological resources are confidential.

Public Resources Code Section 5097.5 and Section 30244 prohibit the removal of any paleontological site or feature from public lands without permission of the jurisdictional agency, define the removal of paleontological sites or features as a misdemeanor, and require reasonable mitigation of adverse impacts to paleontological resources from developments on public (state, county, city, district) lands.

Page 988 of 1828 ends
Page 989 of 1828 ends

City of Covina Public Storage Project i ESA / D202100759.02 Paleontological Resources Assessment February 2022

TABLE OF CONTENTS
City of Covina Public Storage Project 
Paleontological Resources Assessment
Page
Executive Summary ........................................................................................................... ES-1 Introduction .............................................................................................................................. 1 Project Location ................................................................................................................ 1 Project Description ........................................................................................................... 1 Regulatory Framework ............................................................................................................ 5 California Environmental Quality Act ................................................................................ 5 California Penal Code Section 622.5 ............................................................................... 5 California PRC Section 5097.5 ......................................................................................... 5 Los Angeles County General Plan ................................................................................... 6 Society for Vertebrate Paleontology Standard Guidelines ............................................... 6 Paleontological Resources Significance Criteria ............................................................. 6 Methods .................................................................................................................................... 8 Results ...................................................................................................................................... 8 Geologic Setting ............................................................................................................... 8 LACM Records Search ..................................................................................................... 9 Paleontological Sensitivity Analysis ............................................................................... 12 Conclusions and Recommendations .................................................................................. 12 References .............................................................................................................................. 12 Appendices
A. Personnel
B. LACM Records Search

Page 990 of 1828 ends

Table of Contents
Page
City of Covina Public Storage Project ii ESA / D202100759.02 Paleontological Resources Assessment February 2022
List of Figures
Figure 1 Regional Location Map .............................................................................................. 2 Figure 2 Local Vicinity Map ...................................................................................................... 3 Figure 3 Project Location ......................................................................................................... 4 Figure 4 Geologic Map ........................................................................................................... 10 List of Tables
Table 1 Fossil Localities Recorded in the Vicinity of Project Site ......................................... 11

Page 991 of 1828 ends

City of Covina Public Storage Project ES-1 ESA / D202100759.02 Paleontological Resources Assessment February 2022

EXECUTIVE SUMMARY
City of Covina Public Storage Project –
Paleontological Resources Assessment
Environmental Science Associates (ESA) has been retained by the City of Covina (City) to conduct a paleontological resources assessment for the City of Covina of Public Storage Project (Project). This assessment identifies and evaluates the potential impacts to paleontological resources associated with the Project for the purpose of complying with the California Environmental Quality Act (CEQA). The Project proposes the development of a 141,984 square foot 3-story public self-storage building within a 2.70-acre site (Project Site). The scope of work for this assessment included a geologic map review, review of the geotechnical study conducted for the Project, a paleontological resources records search through the Natural History Museum of Los Angeles County (LACM), and the recommendation of mitigation measures to reduce impacts from the Project to paleontological resources to a less than significant level.

Geologic mapping and the Geotechnical Report indicate that the Project Site is underlain entirely by Quaternary alluvium. The paleontological records search conducted through the LACM indicates that no known fossils were located in the Project Site. However, significant fossils have been recovered from Pleistocene units and older Miocene marine formations near the Project Site.

The geotechnical report specifically indicates that only younger, Quaternary alluvium was penetrated at depths down to 30 feet below ground surface (bgs). Excavations associated with the Project are not anticipated go below 10 feet bgs, thus Project excavation has a low potential to encounter the geological units of high paleontological sensitivity.

Based on these results, ESA does not recommend paleontological mitigation measures.

Page 992 of 1828 ends

Executive Summary
City of Covina Public Storage Project ES-2 ESA / D202100759.02 Paleontological Resources Assessment February 2022
This page intentionally left blank

Page 993 of 1828 ends

City of Covina Public Storage Project 1 ESA / D202100759.02 Paleontological Resources Assessment February 2022

CITY OF COVINA PUBLIC STORAGE

PROJECT
Paleontological Resources Assessment
Introduction
Environmental Science Associates (ESA) has been retained by the City of Covina (City) to conduct a paleontological resources assessment for the City of Covina Public Storage Project (Project) in support of an environmental document being prepared pursuant to the California Environmental Quality Act (CEQA). The Project proposes the development of a 141,984 square foot (sf) 3-story public self-storage building within a 2.70-acre site (Project Site). The City is the lead agency pursuant to the CEQA.

ESA personnel involved in this assessment are as follows: Candace Ehringer, M.A., RPA Project Manager; Russell Shapiro, Ph.D., Principal Investigator and report author; Fatima Clark, B.A., report contributor; and Stephan Geissler, GIS specialist. Resumes of key personnel are included in Appendix A of this report.

Project Location
The 2.70-acre Project Site is located at 1330 East Cypress Street (Assessor Parcel Number 8427- 001-006) within the northeastern portion of the City in Los Angeles County, California (Figure 1). The Project Site is bounded by East Cypress Street to the north, the Southern Pacific Railroad to the south, and commercial uses to the east and west (Figure 2). The Project Site is situated within Section 33 of Township 1 North, Range 9 West on the San Dimas, CA U.S.

Geological Survey (USGS) 7.5-minute topographic quadrangle (Figure 3).

Project Description
The Project Site is currently improved with an approximately 189,312 sf two-story commercial building occupied by “TT Electronics Power Solutions” which is used for electronics manufacturing. The remainder of the Project Site consists of asphalt-paved surface parking lots along the northern, eastern, and western portions of the Project Site.

The Project proposes the development of a 141,984 sf, 3-story public self-storage building (up to 30 feet, 7 inches in height). Project components would include a partial basement, a rental office, a temporary monopole cell tower, associated secured surface parking areas, pedestrian walkways, and landscaping. Project implementation would require the removal of 16 trees. Per the City’s Design Guidelines, one tree per 500 sf of landscaped area is required, resulting in 20 required trees. Ground disturbance associated with the Project will reach a maximum depth of 10 feet below ground surface (bgs).

Page 994 of 1828 ends

Alhambra
Monterey
Park
Altadena
asadena
Lakewood
Downey
2 2
Angeles
National Forest
Singing
Springs
60 39
210
2 210
San Gabriel
Wilderness Area
Monrovia
Wilderness
Preserve
Walnut City
Parkland
Vincent
Baldwin Park
Arcadia Glendora
Montebello
Rosemead Covina
Azusa
San Gabriel
El Monte West Covina
57 91
91 19
60 Firestone Boy
Scout
Reservation
Cerritos
Whittier
Buena Park
Bellflower Yorba Linda
Norwalk
Fullerton
Anaheim
Wrightwood
60 210
Upland
Montclair
Claremont
La Verne
Ontario
Pomona
83 91
Chino Hills State
Park
Chino Hills
Chino
Path: U:\GIS\GIS\Projects\2021xxx\D202100759_02_Covina_Public_Self_Storage\03_MXDs_Projects\PD.aprx, sgeissler 1/27/2022 SOURCE: ESRI
N
0 4
Miles
Ø
Project Area
Figure 1
Regional Location Map
City of Covina Public Storage Project
Project
Location

Page 995 of 1828 ends

E Covina Blvd Charter Oak N Damato Dr
N Jenifer Ave
E Wingate St
N Ivescrest Ave
N Bender Ave
E Colver Pl
E Edna Pl
N Glendora Ave
E Cypress St
Kahler Russell
Park
E Covina Blvd
St. Louise D
Marillac
Elementar
School
Charter Oak
High School
Charter Oak Creek
Southern Pacific RR
E Retford St
E Farland St
N Rimhurst Ave
E Colver Pl
N Banna Ave
N Mangrove Ave
E Cypress St
Sonrise
Christian
Charter Oak
High School
Path: U:\GIS\GIS\Projects\2021xxx\D202100759_02_Covina_Public_Self_Storage\03_MXDs_Projects\PD.aprx, sgeissler 1/27/2022 N
SOURCE: Mapbox, 2021 City of Covina Public Storage Project Figure 2
Local Vicinity Map
0 500
Feet
Project Site

Page 996 of 1828 ends

Path: U:\GIS\GIS\Projects\2021xxx\D202100759_02_Covina_Public_Self_Storage\03_MXDs_Projects\Cultural.aprx, sgeissler 12/2/2021 N
SOURCE: USGS Topoquads: Baldwin Park, San Dimas City of Covina Public Storage Project Figure 3
Project Location
0 2,000
Feet
Project Site

Page 997 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 5 ESA / D202100759.02 Paleontological Resources Assessment February 2022
Regulatory Framework
Paleontological resources are limited, nonrenewable resources of scientific, cultural, and educational value that are afforded protection under state laws and regulations. The following section summarizes the applicable state laws and regulations, as well as professional standards.

California Environmental Quality Act
The State CEQA Guidelines (Title 14, Chapter 3 of the California Code of Regulations, Section 15000 et seq.), define the procedures, types of activities, individuals, and public agencies required to comply with CEQA. As part of CEQA’s Initial Study process, one of the questions that must be answered by the lead agency relates to paleontological resources: “Will the proposed project directly or indirectly destroy a unique paleontological resource or site or unique geologic feature?” (State CEQA Guidelines, Appendix G, Section VII, Part f).

The loss of a significant paleontological resources which includes any identifiable fossil that is unique, unusual, rare, uncommon, diagnostically or stratigraphically important, and/or those that add to an existing body of knowledge in specific areas – stratigraphically, taxonomically, and/or regionally, would be a significant environmental impact. Direct impacts to paleontological resources primarily concern the potential destruction of nonrenewable paleontological resources and the loss of information associated with these resources. This includes the unauthorized collection of fossil remains. If potentially fossiliferous bedrock or surficial sediments are disturbed, the disturbance could result in the destruction of paleontological resources and subsequent loss of information.

The CEQA threshold of significance for a significant impact to paleontological resources is reached when a project is determined to “directly or indirectly destroy a significant paleontological resource or unique geologic feature” (State CEQA Guidelines Appendix G, Section VII, Part f). In general, for project sites that are underlain by paleontologically sensitive geologic units, the greater the amount of ground disturbance, the higher the potential for significant impacts to paleontological resources.

California Penal Code Section 622.5
California Penal Code Section 622.5 provides the following: “Every person, not the owner thereof, who willfully injures, disfigures, defaces, or destroys any object or thing of archeological or historical interest or value, whether situated on private lands or within any public park or place, is guilty of a misdemeanor.”
California PRC Section 5097.5
California PRC Section 5097.5 provides protection for paleontological resources on public lands, where Section 5097.5(a) states, in part, that:

No person shall knowingly and willfully excavate upon, or remove, destroy, injure, or deface, any historic or prehistoric ruins, burial grounds, paleontological or vertebrate paleontological site, including fossilized footprints,

Page 998 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 6 ESA / D202100759.02 Paleontological Resources Assessment February 2022
inscriptions made by human agency, rock art, or any other paleontological, paleontological or historical feature, situated on public lands, except with the express permission of the public agency having jurisdiction over the lands Los Angeles County General Plan
The City does not include any goals or policies for the protection of paleontological resources.

However, the Conservation and Natural Resources Element (the Element) of the Los Angeles County General Plan indicates that “Historic, cultural, and paleontological resources are an important part of Los Angeles County’s identity” (Los Angeles County General Plan, 2015:163).

The Element provides the following goal and policies for the treatment of historic resources:

Goal C/NR 14: Protected historic, cultural, and paleontological resources.

Policy C/NR 14.1: Mitigate all impacts from new development on or adjacent to historic, cultural, and paleontological resources to the greatest extent feasible.

Policy C/NR 14.2: Support an inter-jurisdictional collaborative system that protects and enhances historic, cultural, and paleontological resources.

Policy C/NR 14.3: Support the preservation and rehabilitation of historic buildings.

Policy C/NR 14.5: Promote public awareness of historic, cultural, and paleontological resources.

Policy C/NR 14.6: Ensure proper notification and recovery processes are carried out for development on or near historic, cultural, and paleontological resources.

Society for Vertebrate Paleontology Standard Guidelines The Society of Vertebrate Paleontology (SVP) Guidelines (SVP, 2010) outline professional protocols and practices for conducting paleontological resource assessments and surveys, monitoring and mitigation, data and fossil recovery, sampling procedures, specimen preparation, identification, analysis, and curation. Most practicing professional vertebrate paleontologists adhere closely to the SVP’s assessment, mitigation, and monitoring requirements as specifically provided in its standard guidelines. Most state and local regulatory agencies accept and use the professional standards set forth by the SVP.

Paleontological Resources Significance Criteria
As defined by the SVP (2010:11), significant nonrenewable paleontological resources are:

Fossils and fossiliferous deposits, here defined as consisting of identifiable vertebrate fossils, large or small, uncommon invertebrate, plant, and trace fossils, and other data that provide taphonomic, taxonomic, phylogenetic, paleoecologic, stratigraphic, and/or biochronologic information. Paleontological resources are considered to be older than recorded human history and/or older than middle Holocene (i.e., older than about 5,000 radiocarbon years).

Page 999 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 7 ESA / D202100759.02 Paleontological Resources Assessment February 2022
Numerous paleontological studies have further developed criteria for the assessment of significance for fossil discoveries (e.g., Eisenstraut and Cooper, 2002; Murphey and Daitch, 2007; Scott and Springer, 2003, etc.). In general, these studies assess fossils as significant if one or more of the following criteria apply:

1. The fossils provide information on the evolutionary relationships and developmental trends among organisms, living or extinct.

2. The fossils provide data useful in determining the age(s) of the rock unit or sedimentary stratum, including data important in determining the depositional history of the region and the timing of geologic events therein.

3. The fossils provide data regarding the development of biological communities or interaction between paleobotanical and paleozoological biotas.

4. The fossils demonstrate unusual or spectacular circumstances in the history of life.

5. The fossils are in short supply and/or in danger of being depleted or destroyed by the elements, vandalism, or commercial exploitation, and are not found in other geographic locations.

In summary, significant paleontological resources are determined to be fossils or assemblages of fossils that are unique, unusual, rare, uncommon, or diagnostically important (Eisenstraut and Cooper, 2002; Murphey and Daitch, 2007; Scott and Springer, 2003). Significant fossils can include remains of large to very small aquatic and terrestrial vertebrates or remains of plants and animals previously not represented in certain portions of the stratigraphy. Assemblages of fossils that might aid stratigraphic correlation, particularly those offering data for the interpretation of tectonic events, geomorphologic evolution, and paleoclimatology are also critically important (Scott and Springer, 2003; Scott et al., 2004).

Paleontological Potential
Paleontological potential is defined as the potential for a geologic unit to produce scientifically significant fossils. This is determined by rock type, the past history of the geologic unit in producing significant fossils, and the fossil localities recorded from that unit. Paleontological potential is derived from the known fossil data collected from the entire geologic unit and not just from one specific survey. In its “Standard Procedures for the Assessment and Mitigation of Adverse Impacts to Paleontological Resources,” the SVP (2010) defines four categories of paleontological sensitivity (potential) for rock units: high, low, undetermined, and no potential.  High Potential. Rock units from which vertebrate or significant invertebrate, plant, or trace fossils have been recovered are considered to have a high potential for containing additional significant paleontological resources. Rocks units classified as having high potential for producing paleontological resources include, but are not limited to, sedimentary formations and some volcaniclastic formations (e. g., ashes or tephras), and some low-grade metamorphic rocks which contain significant paleontological resources anywhere within their geographical extent, and sedimentary rock units temporally or lithologically suitable for the preservation of fossils (e. g., middle Holocene and older, fine-grained fluvial sandstones, argillaceous and carbonate-rich paleosols, cross-bedded point bar sandstones, fine-grained marine sandstones, etc.).

Page 1000 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 8 ESA / D202100759.02 Paleontological Resources Assessment February 2022
 Low Potential. Reports in the paleontological literature or field surveys by a qualified professional paleontologist may allow determination that some rock units have low potential for yielding significant fossils. Such rock units will be poorly represented by fossil specimens in institutional collections, or based on general scientific consensus only preserve fossils in rare circumstances and the presence of fossils is the exception not the rule, e. g. basalt flows or Recent colluvium. Rock units with low potential typically will not require impact mitigation measures to protect fossils.
 Undetermined Potential. Rock units for which little information is available concerning their paleontological content, geologic age, and depositional environment are considered to have undetermined potential. Further study is necessary to determine if these rock units have high or low potential to contain significant paleontological resources. A field survey by a qualified professional paleontologist to specifically determine the paleontological resource potential of these rock units is required before a paleontological resource impact mitigation program can be developed. In cases where no subsurface data are available, paleontological potential can sometimes be determined by strategically located excavations into subsurface stratigraphy.
 No Potential. Some rock units have no potential to contain significant paleontological resources, for instance high-grade metamorphic rocks (such as gneisses and schists) and plutonic igneous rocks (such as granites and diorites). Rock units with no potential require no protection nor impact mitigation measures relative to paleontological resources.

For geologic units with high potential, full-time monitoring is generally recommended during any project-related ground disturbance. For geologic units with low potential, monitoring will not generally be required. For geologic units with undetermined potential, field surveys by a qualified vertebrate paleontologist should be conducted to specifically determine the paleontological potential of the rock units present within the Project Site.

Methods
The Project Site was the subject of thorough background research and analysis to assess its paleontological sensitivity. The research included geologic map review, review of the Geotechnical Engineering Exploration and Analysis report (Geotechnical Report) prepared for the Project, and a paleontological records search conducted by the Natural History Museum of Los Angeles (LACM). Given the developed and paved nature of the Project Site, a paleontological resources pedestrian survey of the Project Site was not conducted. The results of these tasks are provided in the following section.

Results
Geologic Setting
The greater Los Angeles area comprises a set of tectonically-bound basins, filled with very thick sequences of marine and terrestrial sediment (Yerkes et al., 1965). The uplifted mountain ranges surround these basins are composed of bedrock of various ages and supply the sediment to the valleys below. The rates of erosion and deposition are linked to tectonic uplift as well as climate patterns. The fossils entombed in these valley sediments likewise show the variations in climate conditions as well as depositional environments.

Page 1001 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 9 ESA / D202100759.02 Paleontological Resources Assessment February 2022
The Project is located in what Yerkes et al. (1965) describe as the “Northeastern Block”. This depositional basin is bounded on the north by the Sierra Madre and San Gabriel Mountains. Just south of the Project, the San Jose Hills rise as a folded anticline, dividing the valley. The Project Site itself is underlain by alluvium eroded off the San Jose Hills and also seeing the influence of erosion of the San Gabriel Mountains. Mapping by Dibblee and Minch (2002) clearly show this influence as apron of older, Pleistocene alluvium at a higher elevation around the uplifted hills with younger alluvium filling in the valley between.

Near the Project, specifically, a blanket of older alluvium (Qoa) skirts the base of the San Jose Hills and likely continues in the subsurface below the Project (Dibblee and Minch, 2002) but at a depth below the proposed excavation. The surface is covered by younger Holocene-age alluvium (Qa) as is the rest of the San Gabriel Valley (Figure 4). The San Jose Hills to the south as well as uplifts to the north expose older, Miocene-age marine sediments and volcanic rocks. The following summarizes the only geologic unit within the Project Site that could be potentially impacted by Project implementation:

Geotechnical Report Review
Giles Engineering Associates performed a geotechnical exploration and analysis of the Project in 2021 (Giles Engineering Associates, 2021). The analysis included eight truck-mounted borings down to 36.5 feet bgs. The logs showed that the geology below artificial fill extended to a depth of 6 feet bgs, followed by a consistently unlithified brown silty sand to sand, with some gravels and cobbles. None of the borings pierced a significant change in sediments, suggesting that the potentially underlying older alluvium was not reached. Therefore, this report concurs that younger alluvium occurs at depth throughout the Project Site at least to the proposed excavation depths.

LACM Records Search
On December 3, 2021, ESA commissioned a paleontological resources records search through the LACM (Appendix B). This records search entailed an examination of current geologic maps and known fossil localities inside and within the general vicinity of the Project Site. The purpose of the records search is to determine whether or not there are previously recorded paleontological resources or fossiliferous geological formations within the Project Site that require evaluation.

The results also provide a basis for assessing the sensitivity of the Project Site for additional and buried resources.

Results of the paleontological resources records search conducted by the LACM indicated that no fossil localities lie directly within the Project Site; however, 11 fossil localities (LACM IP 4723, and LACM VP 1728, 3363, 6166, 6167, 6173, 7268, 7271, and 7508)) were identified nearby from sedimentary deposits occurring near the Project Site (Table 1).

Page 1002 of 1828 ends

Path: U:\GIS\GIS\Projects\2021xxx\D202100759_02_Covina_Public_Self_Storage\03_MXDs_Projects\Cultural.aprx, sgeissler 2/16/2022 SOURCE: Geologic map San Dimas and Ontario quadrangles, 2002; ESA, 2022 City of Covina Public Storage Project Figure 4
Geologic Map
N
0 2,000
Feet
Project Site
Qa: Holocene-aged alluvium
Qoa: Pleistocene-age (older) alluvium
Project
Site

Page 1003 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 11 ESA / D202100759.02 Paleontological Resources Assessment February 2022
TABLE 1

FOSSIL LOCALITIES RECORDED IN THE VICINITY OF PROJECT SITE Locality No. Formation Taxa Depth

LACM IP
4723
Puente Formation
(shale)
unspecified invertebrates Unknown

LACM VP
1728
Unknown (light
brown shale with
interbeds of very
coarse brown
sand; Pleistocene)
Horse (Equus), camel
(Camelops)
15-20 ft
bgs

LACM VP
3363
Unknown
Formation
(Pleistocene; sand
and silt)
Horse (Equus) Unknown

LACM VP
6166, 6167,
6173
Puente Formation
(shale)
Mako shark (Isurus
planus),Sturgeonfish
(Prionurus), extinct bony
fish (Etringus)
Unknown

LACM VP
7268, 7271
Unknown
(Pleistocene)
Horse (Equus) Unknown

LACM VP
7508
Unknown
formation
(Pleistocene)
Ground sloth
(Nothrotheriops);
elephant family
(Proboscidea); horse
(Equus)
Unknown

LACM VP
7701, 7702
Unknown
Formation
(Pleistocene; silt)
Fish (Gasterosteus);
Snake (Colubridae),
Rodents (Thomomys,
Microtus,
Reithrodontomys);
Rabbit (Sylvilagus)
30 ft bgs
VP = Vertebrate Paleontology; IP = Invertebrate Paleontology SOURCE: LACM, 2021
Localities LACM VP 6166, 6167, 6173 and LACM IP 4723 yielded fossil specimens of Mako shark (Isurus planus), Sturgeonfish (Prionurus), extinct bony fish (Etringus) and unspecified invertebrates within shale sediments of the Puente Formation at unknown depths. LACM VP 1728 produced fossil specimens of horse (Equus) and camel(Camelops) within Pleistocene deposits at depths between 15 and 20 feet bgs. LACM VP 7268 and 7271 yielded fossil specimens of horse (Equus) within Pleistocene deposits at unknown depths. LACM VP 7508 yielded fossil specimens of ground sloth (Nothrotheriops), elephant family (Proboscidea), and horse (Equus) within Pleistocene deposits at unknown depths. Localities LACM VP 7701 and 7702 yielded fossil specimens of fish (Gasterosteus), snake (Colubridae), rodents (Thomomys, Microtus, Reithrodontomys), and rabbit (Sylvilagus) at 30 feet bgs. LACM VP 3363 yielded a fossil specimen of horse within Pleistocene deposits at an unknown depth (Bell, 2021).

However, it should be noted that the detailed analysis of the geological map and Geotechnical Report suggests that Pleistocene alluvium, as well as the older Miocene marine units such as the Puente Formation, do not occur within the Project Site, and would not be encountered during Project implementation.

Page 1004 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 12 ESA / D202100759.02 Paleontological Resources Assessment February 2022
Paleontological Sensitivity Analysis
The geologic mapping and Geotechnical Report reviews, as well as the LACM records search results were used to assign paleontological sensitivity to the geologic unit at surface and underlying the Project Site, following the guidelines of the SVP (2010):

Fill Material: As indicated by the Geotechnical Report, fill material is present within the first 6 feet underlying the Project Site. It is unclear as to where the fill material came from and so assigning an age is impossible. Given the disturbed nature of the fill it is unlikely to contain intact fossiliferous deposits. Therefore, this unit is assigned No Potential to contain paleontological resources.

Qa: Underlying the fill material beyond 6 feet bgs is Holocene-age Quaternary alluvium, dating to 11,700 years ago to present. Fossil specimens have not been identified within nearby Holocene-age sediments by the LACM records search; however, SVP guidelines indicate that fossils can be as young as 5,000 years old, a time frame encompassing the age of these sediments.

While excavation into the uppermost (or more recent) layers of these Holocene deposits would not impact fossils, deep excavations into Holocene-age soils could encounter paleontological resources per the SVP’s minimum age threshold (e.g., 5,000 years) for what may constitute a fossil. Therefore, this unit is assigned a Low Potential to contain paleontological resources.

Based on the Geotechnical Report, no early Holocene or late Pleistocene alluvium was encountered. However, as the thickness of Qa has not been established, it should be assumed that Qoa underlies Qa and could be impacted by excavation activities (see below).

Conclusions and Recommendations
Project ground disturbing activities will include excavations extending to depths of 10 feet bgs.

Geotechnical testing indicates a layer of fill material extends from the surface to a depth of 6 feet bgs. Artificial fill has no paleontological potential, therefore excavations in this unit will not impact paleontological resources. The fill is underlain to a depth of 36 feet by Holocene-age Quaternary alluvium, which has low potential to contain paleontological resources. Given the low potential of the Quaternary alluvium, Project-related ground disturbance is unlikely to impact paleontological resources and no mitigation measures are recommended.

References
Bell, Alyssa. 2021. Results of a paleontological resources records search titled re: Paleontological resources for the Covina Public Self-Storage Facility Project (D202100759.02). Prepared by the Natural History Museum of Los Angeles County on December 10, 2021. Results letter on file at ESA.

Dibblee, T.W., and Minch, J.A. 2002. Geologic map of the San Dimas and Ontario quadrangles, Los Angeles and San Bernardino Counties, California. Dibblee Geological Foundation Map DF-91, scale 1:24,000.

Giles Engineering Associates, 2021, Geotechnical engineering exploration and analysis, proposed 3-story public storage building, 1330 East Cypress Street, Covina California.

Page 1005 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 13 ESA / D202100759.02 Paleontological Resources Assessment February 2022
Murphey, P. C., and D. Daitch. 2007. Paleontological overview of oil shale and tar sands areas in Colorado, Utah and Wyoming. Scale 1:500,000. U.S. Department of Energy, Argonne National Laboratory. Report prepared for the U.S. Department of Interior Bureau of Land Management.

Scott, E. and K. Springer. 2003. CEQA and Fossil Preservation in California. The Environmental Monitor.

Scott, E., K. Springer, and J. C. Sagebiel. 2004. Vertebrate paleontology in the Mojave Desert:
the continuing importance of “follow-through” in preserving paleontologic resources. In The human journey and ancient life in California’s deserts: Proceedings from the 2001 Millennium Conference. Ridgecrest: Maturango Museum Publication 15:65-70.

Society of Vertebrate Paleontology (SVP). 2010. Standard procedures for the assessment and mitigation of adverse impacts to paleontological resources.

Yerkes, R. F., T. H. McCulloh, J. E. Schollhamer, and J. G. Vedder. 1965. Geology of the Los Angeles Basin – an introduction. Geological Survey Professional Paper 420-A.

Page 1006 of 1828 ends

Paleontological Resources Assessment
City of Covina Public Storage Project 14 ESA / D202100759.02 Paleontological Resources Assessment February 2022
This page intentionally left blank

Page 1007 of 1828 ends
Page 1008 of 1828 ends
Page 1009 of 1828 ends

Candace is a cultural resources project manager with 22 years of experience in California. She provides technical and compliance oversight for archaeological survey, evaluation, and treatment; built environment studies, including the documentation and evaluation of buildings, structures, and districts; Tribal resources consultations; and paleontological resources survey and sensitivity assessments. Candace also has experience working with agencies and Tribes to identify Traditional Cultural Properties and tribal cultural resources. She is skilled in the evaluation, analysis of effects, and development of measures to avoid, minimize, or mitigate adverse effects for tribal, archaeological, historic, and paleontological resources under Section 106 and CEQA.

Candace manages multi-disciplinary cultural resources projects and is adept at building teams of specialists that are uniquely qualified for the project at hand.

Her project work includes experience in every county in Southern California, as well as many in the Central Coast, Central Valley, and Northern California regions. She is proficient in the areas of CEQA, NEPA, Section 106, and AB 52 compliance, and routinely provides planning and strategic guidance to clients on complex projects within the larger scope of state and federal regulations.

California Department of Water Resources, Cantua Creek Stream Group Improvements Project, Fresno County, CA. Project Manager. Candace managed the preparation of a Cultural Resource Inventory and Evaluation Report, Finding of Effect, and Paleontological Resources Report in compliance with Section 106 of the National Historic Preservation Act and CEQA. The California Department of Water Resources (DWR) proposes to implement the Cantua Creek Stream Group (CCSG) Improvements Project (Project). The CCSG is composed of five major creeks: Arroyo Hondo, Cantua, Salt, Martinez, and Domengine. The CCSG drains a portion of the Coast Range, located west of the Project area. Presently, floodwaters from the CCSG terminate at four locations (Basins 1-4) along an approximately 13-mile stretch of the San Luis Canal; Martinez Creek flows into Salt Creek about 3 miles upstream of the San Luis Canal.

Irvine Ranch Water District (IRWD), Syphon Reservoir Geotechnical Investigations MND, Orange County, CA. Cultural Resources Manager. Candace managed paleontological and archaeological monitoring of geotechnical work in compliance with the project’s mitigation measures. IRWD is conducting geotechnical investigations to support potential future enlargement of the existing Syphon Reservoir. Additionally, geotechnical explorations would verify the characteristics of the Center Valley Fault, which previously has been documented as inactive. The project has used exploratory test pits, borings, and geophysical surveys to characterize the subsurface conditions of the soil and bedrock at each exploration location.

EDUCATION
MA, Anthropology,
California State
University, Northridge
BA, Anthropology, East
Carolina University
22 YEARS OF

EXPERIENCE

AREAS OF

EXCELLENCE
CEQA, NEPA, Section
106, and AB 52
proficient
Manages multidisciplinary CRM
projects
Strong historic
resources research skills

QUALIFICATIONS
Register of Professional
Archaeologists, No.
15146
Meets Caltrans PQS for
Co-Principal
Investigator
Meets Secretary of the
Interior’s PQS for
Archaeology and
History
Orange County Certified
Archaeologist
CA State BLM
Permitted
HAZWOPER Certified

Page 1010 of 1828 ends

Irvine Ranch Water District (IRWD), Tustin Wells MND/EA, Orange County, CA.

Cultural Resources Project Manager. Candace conducted a Phase I cultural resources study for the Tustin Wells Project. She led the cultural resources survey and authored a technical report. The project will recover and treat impaired groundwater to augment local water supplies and increase water supply reliability.

Eastern Municipal Water District Local Groundwater Banking Project, San Jacinto, CA. Project Director. Candace directed the cultural resources component of the project, including historic, archaeological, and paleontological resources studies. ESA prepared an EIR for the proposed project, which would develop a water bank with storage capacity up to 128,000 acre feet. ESA is currently providing cultural resources monitoring during project construction.

Los Angeles Department of Water and Power (LADWP), East Hollywood District Yard Demolition, Los Angeles, CA. Cultural Resources Project Director. Candace directed the preparation of historic, archaeological, and paleontological studies and provided senior review of all deliverables. The project includes redevelopment of LADWP’s East Hollywood District Yard. The results of the analyses were incorporated into the IS/MND.

Corona-Keith 1220 Zone Potable Water Tank City of Corona, Keith 1220-Zone Potable Water Tank MND, City of Corona, CA. Cultural Resources Project Manager. Candace managed the preparation of cultural resources and paleontological resources assessments, which included archival research, survey, and preparation of technical reports. The project includes the construction of a tank on approximately 0.9 acre owned by the City of Corona on the southeast corner of the intersection of Nelson Street and Keith Street.

The project also included proposed utility lines (potable water, reclaimed water and drainage lines) that would extend from the proposed tank site along Nelson Street to Courtney Lane, east along Courtney Lane and north within Howe Street to Duncan Way.

County of Los Angeles Department of Public Works (County), Rancho Los Amigos South Campus EIR, Downey, CA. Cultural Resources Project Manager. Candace managed cultural resources studies in support of the EIR, including reevaluation of the historic district, archaeological and paleontological assessments, and assistance with AB 52 consultation. The County proposes redevelopment of a portion of the Rancho Los Amigos (RLA) South Campus which is located in the City of Downey. The 74-acre RLA South Campus was the home of the “Los Angeles County Poor Farm” that was established in 1880s to provide room and board to indigent citizens in exchange for agricultural labor, then served as an infirmary and later evolved into a hospital facility in 1932.

The RLA South Campus functioned as a major hospital complex from 1956 to the 1990s, when it was abandoned. The RLA South Campus is currently unoccupied and houses a National Register-eligible historic district. The County is proposing redevelopment of a 21-acre portion of the RLA South Campus with County uses, including a Sheriff’s Station Crime Laboratory, Internal Services Department Headquarters, and Probation Department Headquarters. The project will include supporting parking and installation of utilities and other features on a site that has been abandoned for nearly 30 years. Building demolition and/or repurposing or relocation of existing buildings will be required.

Page 1011 of 1828 ends

Russell S. Shapiro, PhD
Principal Investigator
As a Principal Investigator, Dr. Shapiro has been involved in review of paleontological resource reports and evaluating proposed mitigation plans.

Dr. Shapiro researches and prepares environmental impact reports regarding cultural resources (fossils), conducts field (geological and paleontological) surveys, and oversees ground disturbance at construction sites for Environmental Quality compliance (CEQA, NEPA, and the Paleontological Resources Preservation Act ). As a Qualified Paleontologist, Dr. Shapiro has also reviewed resource planning documents for several counties in California and was the lead on the Bureau of Land Management’s assessment of fossil resources of Northern California.

In his academic role as Professor of Geology, Dr. Shapiro teaches several paleontology courses including “Applied Paleontology” which is a modified “Cultural Resources” course, focusing on budgeting, CEQA and NEPA regulations, field surveys, GIS projections, fossil recovery, and curation. He also teaches in the annual Field Camp courses and manages the rock preparation lab and maintains the microscopes.

Relevant Experience
ReneSola Gentry Solar Project, Paleontological Resource Assessment Report, Lincoln, California. Principal Investigator, Mapping. Literature, geological map, and museum review for fossil resources. Field mapping of entire property. Final product included a mitigation and monitoring plan.

Paleontological Sensitivity Analysis Report, Elk Grove, California; Pacific Gas and Electric. Principal Investigator. Literature, geological map, and air photo archival report on the potential fossil yield for a proposed pipeline.

Recommendations based on searches of museum collections of relevant geological formations. Deliverables consisted of a sensitivity report and appendix of known fossil occurrences by taxa and location.

Mojave Solar Project Cultural Services; San Bernardino County, California; CH2M Hill. Principal Investigator. Reviewed technical report; advised on scientific analyses.

El Camino Real Bridge Replacement Environmental Services; San Luis Obispo County, California, Quincy Engineering. Principal Investigator. Reviewed technical report for CEQA/NEPA documentation, technical studies, and permitting, for the replacement of the El Camino Real bridge over Santa Margarita Creek in Atascadero.

EDUCATION
Ph.D., Geological
Sciences, University of
California, Santa
Barbara, 1998
B.S., Geology, Humboldt
State University, 1992
25 YEARS EXPERIENCE

CERTIFICATIONS/

REGISTRATION
U.S. Fish and Wildlife
Cultural Resources Use
Permit
U.S. Forest Service
Cultural Resources Use
Permit
Bureau of Land
Management Cultural
Resources Use Permit
Wilderness and Remote
First Aid (Red Cross
Certified)

PROFESSIONAL

AFFILIATIONS
Geobiology Society;
Treasurer
Society for Sedimentary
Geology (SEPM); VicePresident
Society for Vertebrate
Paleontology

Page 1012 of 1828 ends

Russell S. Shapiro, PhD

Page 2 ends

San Bernardino County General Plan Update: Paleontological Resources Technical Report. Primary Reviewer. External reviewer for general plan update.

Involved assessing all geological formations in San Bernardino County and museum records of significant fossils.

Recent Significant Excavations
Miocene Vertebrates of the Sheldon Wildlife National Refuge. Oversaw operations to conduct significant collection of Miocene-age fossils from volcanic sediments for the U.S. Fish and Wildlife Service. Duties included field collection and high-resolution GPS mapping, fossil preparation and identification, curation at the Gateway Science Museum.

Eocene Horses from Black Butte Lake Reservoir. Field jacketing and preparation of fossil horse skull material from the reservoir under the direction of the U.S. Army Corps of Engineers. Fossils were prepared, identified, and returned to the Army Corps for public display.

Pleistocene Camelid from Nevada. This project grew out of a paleontological resource assessment field survey. During the survey, a semi-articulated rear leg of a late Pleistocene camelid was collected and prepared. A manuscript was published in 2016.

Publications and Presentations
Shapiro, R. S., 2016, Camelid record of Mesquite Lake, California: impact of earliest Holocene climate change in Reynolds, R. E., ed., Going LOCO investigations along the Lower Colorado River, 2016 Desert Symposium Field Guide and Proceedings, p 41-47.

Shapiro, R. S. and Konhauser, K. O., 2014, Hematite-coated microfossils:

Ecological fingerprint or taphonomic oddity of the Paleoproterozoic? Geobiology, v. 13, p. 209-224.

Shapiro, R. S. and Spangler, E., 2009, Bacterial fossil record in whale falls: relation of taphonomy and paleoecology to depositional environment:

Palaeogeography, Palaeoclimatology, Palaeoecology, v. 274, p. 196-203.

Shapiro, R. S., Fricke, H., and Fox, K., 2009, Dinosaur-bearing oncoids from ephemeral lakes of the Lower Cretaceous Cedar Mountain Formation, Utah:

PALAIOS, v. 24, p. 51-58.

Shapiro, R. S., and Rowland, S. M., 2002, Fossil collecting in southern Nevada in Rowland, S. M. and Orndorff, R. L., eds., Geology of the Southern Nevada Region: National Association of Geoscience Teachers, Far Western Section Spring Field Conference Guidebook, p. 96-99.

Shapiro, R. S., 1998, Paleogene-Early Neogene macrofossils of southwestern Santa Cruz Island in Weigand, P. W., ed., Contributions to the Geology of the Northern Channel Islands, Southern California: Pacific Section, American Association of Petroleum Geologists, MP-45, p. 123-132.

Page 1013 of 1828 ends
Page 1014 of 1828 ends
Page 1015 of 1828 ends

Appendix E
Phase I Environmental Site
Assessment

Page 1016 of 1828 ends
Page 1017 of 1828 ends

PHASE I ENVIRONMENTAL SITE ASSESSMENT
conducted on
CA21222
1330 East Cypress Street
Covina, California
Apex Project No. 25021-021079.00
June 9, 2021
Prepared for:

PS Southern California One, Inc., a Delaware corporation; Public Storage, a Maryland real estate investment trust, and its affiliates
701 Western Avenue
Glendale, California 91201
Prepared by:

Apex Companies, LLC
1962 Freeman Avenue
Signal Hill, California 90755

Page 1018 of 1828 ends

TABLE OF CONTENTS

1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.2 Methodology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.3 Reliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.0 SUBJECT PROPERTY DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.1 Building Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

2.2 Site Reconnaissance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

2.3 Physical Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

2.4 Current Uses of Adjoining/ Nearby Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

3.0 HISTORICAL REVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3.1 Summary of Historical Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3.2 Aerial Photographs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

3.3 Topographic Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.4 Fire Insurance Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.5 City Directories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3.6 Recorded Land Title Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3.7 Agency Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

3.8 PREVIOUS ENVIRONMENTAL REPORTS OR OTHER DOCUMENTS . . . . . . . . . . . . 21

4.0 USER PROVIDED INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

5.0 INTERVIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

5.1 Interview with Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

5.2 Interviews with Others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

6.0 STANDARD ENVIRONMENTAL RECORDS SOURCES: FEDERAL, STATE, AND TRIBAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

7.0 TIER 1 VAPOR ENCROACHMENT SCREEN (VES) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

7.1 Tier 1 Screen Evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

7.2 Tier 1 Screening Findings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

8.0 EXCEPTIONS & LIMITING CONDITIONS OF ASSESSMENT . . . . . . . . . . . . . . . . . . . . . . . . . 28

8.1 Unavailable Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

8.2 Lack of Access / Reconnaissance Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

8.3 Data Gaps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

9.0 FINDINGS AND OPINIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Page 1019 of 1828 ends

10.0 CONCLUSIONS AND RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

11.0 SIGNATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

12.0 SOURCES AND REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Page 1020 of 1828 ends

TABLE OF APPENDICES
Site Plan
Site and Vicinity Plan
Photographs
Resumes
Aerial Photographs
Topographic Maps
Fire Insurance Maps
City Directories
Recorded Land Title Documents
Agency Documents
Previous Reports/Miscellaneous Documents
Regulatory Database Report

Page 1021 of 1828 ends

EXECUTIVE SUMMARY
PS Southern California One, Inc., a Delaware corporation; Public Storage, a Maryland real estate investment trust, and its affiliates retained Apex Companies, LLC (Apex) to conduct a Phase I Environmental Site Assessment (“ESA” or “Assessment”) for CA21222 located at 1330 East Cypress Street in Covina (Los Angeles County), California (the “subject property”). The objective of the Assessment was to provide an independent, professional opinion regarding recognized environmental conditions, as defined by ASTM, associated with the subject property. This Assessment was requested in association with Potential property transaction.

This Assessment was performed under the conditions of, and in accordance with Apex's Proposal Number 5307424776, dated May 20, 2021 and ASTM International Practice E1527-13, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. Any exceptions to, additions to, or deletions from the ASTM Practice are described in the report. Details of the work performed, sources of information, and findings are presented in the report. Limitations of the Assessment are described in Section 1.3.

The approximately 2.26-acre subject property is in a residential, commercial, and light industrial setting.

At the time of the walkthrough, the subject property was developed with two adjoining buildings in the center of the property that were occupied by TT Electronics. Building 1 (western building) and the first floor of Building 2 (eastern building) are primarily utilized for manufacturing, assembly, equipment repair, packing, shipping, and quality control of circuit boards for defense industry purposes. Equipment utilized in these processes include UV ovens/coating machines, environmental quality control chambers (e.g., heat stress and vibration chambers), a furnace, cleaning machines, and soldering machines. The second floor of Building 2 is utilized primarily for offices, storage, and an inactive laboratory. Two hazardous materials sheds, cooling towers, and a loading dock are located to the south of Building 1. Additionally, a liquid nitrogen AST and underground clarifier are located to the west of Building 1. Telecommunication antennas with associated equipment are located on the roof of Building 2. The remainder of the subject property consists of asphalt-paved parking lots and small landscaped planters. Access can be gained from East Cypress Avenue to the north.

Based on historical sources, the subject property was depicted as undeveloped land from at least 1894 in the topographic maps until sometime prior to 1928 when the property was developed agriculturally and with a residence in the northwest portion. Agricultural activities ceased and the residence was demolished circa 1964. By 1977, the westernmost building on the subject property was constructed. The easternmost building was constructed circa 1983. The configuration of the subject property has not changed since that time. Tenants of the subject property have included Perkin Elmer, EG&G Power Systems, Almond Instruments, and Excilitas Technologies. TT Electronics has occupied the subject property since June 2020.

A railroad was developed on the south adjoining property from at least 1894. At that time, the remaining adjoining properties were depicted as undeveloped in the topographic map until sometime prior to 1928 when all of the adjoining properties were developed agriculturally. A residence was developed on the east adjoining property circa 1948 and the southernmost west adjoining building was developed circa 1960.

By 1960, the existing north adjoining residences and sports field were developed. Agricultural activities ceased on the remaining adjoining properties and four buildings (commercial usage and gas station) were Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
1

Page 1022 of 1828 ends

developed on the west adjoining property circa 1964. A drycleaner has occupied the central west adjoining building since at least 1966. By 1964, the south adjoining residences were developed. An additional west adjoining commercial building and the existing east adjoining light industrial building were developed by 1972 and 1988, respectively. Between 2002 and 2009 the west adjoining gas station was demolished and the existing auto repair building was constructed.

This Assessment has revealed no evidence controlled recognized environmental conditions in connection with the subject property.

The following recognized environmental conditions were identified during this Assessment:
• Historical Onsite Use of Chlorinated Solvents
• West Adjoining Drycleaner
• Tier 1 Vapor Encroachment Screen
The following historic recognized environmental condition was identified during this Assessment:
• Former West Adjoining Gas Station
Based on Apex’s review of the environmental condition of the subject property, it is recommended that soil vapor sampling be conducted onsite to assess potential contamination from the adjoining drycleaner and the past use of chlorinated solvents onsite. Due to the sensitive nature of onsite activities, sampling will likely need to be conducted around the exterior of the building.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
2

Page 1023 of 1828 ends

1.0 INTRODUCTION
PS Southern California One, Inc., a Delaware corporation; Public Storage, a Maryland real estate investment trust, and its affiliates retained Apex Companies, LLC (Apex) to conduct a Phase I Environmental Site Assessment (“ESA” or “Assessment”) for CA21222 located at 1330 East Cypress Street in Covina (Los Angeles County), California (the “subject property”).

1.1 Purpose
The purpose of the assessment is to follow ASTM International Practice E1527-13 (practice), which defines good commercial and customary practice in the United States of America for conducting an environmental site assessment of a parcel of commercial real estate with respect to the range of contaminants within the scope of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) and petroleum products. As such, this practice is intended to permit a user to satisfy one of the requirements to qualify for the innocent landowner, contiguous property owner, or bona fide prospective purchaser limitation on CERCLA liability (the landowner liability protections or LLPs); that is, the practice that constitutes all appropriate inquiries into the previous ownership and uses of the property consistent with good commercial and customary practice as defined at 42 U.S.C. 9601(35)(B). The term recognized environmental conditions is defined as the presence or likely presence of any hazardous substances or petroleum products in, on, or at the property: (1) due to any release to the environment; (2) under conditions indicative of a release to the environment; or (3) under conditions that pose a material threat of a future release to the environment. De minimis conditions are not recognized environmental conditions.

1.2 Methodology
This Assessment was performed under the conditions of, and in accordance with Apex's Proposal Number 5307424776, dated May 20, 2021 and ASTM International Practice E1527-13, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. The United States Environmental Protection Agency (USEPA) has determined that the ASTM E1527-13 standard is consistent with the requirements for conducting All Appropriate Inquiry (AAI) and may be used to comply with the AAI regulations (40 Code of Federal Regulations [CFR] Part 312). The methods and terms are as defined in the ASTM standard and AAI regulations.

The Assessment included the following components:
• Review information provided by the client. This includes that information required by the Standard with respect to “User Responsibilities” as well as other information provided (e.g., Environmental Liens, Activity and Use Limitations [AULs], Specialized Knowledge). • Review selected information on general geology and topography of the subject property, local groundwater conditions, and proximity to ecologically sensitive receptors, such as streams, that might be impacted by recognized environmental conditions. • Investigate historical use of the subject property through reasonably ascertainable ASTM Standard Historical Sources for evidence of prior land use that could have led to recognized environmental conditions. These Standard Historical Sources may include: aerial photography, United States Geological Survey (USGS) topographic maps, fire insurance maps, local street Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
3

Page 1024 of 1828 ends

directories, property tax files, building department records and zoning/land use records. Unless otherwise specified by the client/proposal this did not include a review of recorded land title records.
• Review of environmental records available from the client, property owner or site contact for evidence of recognized environmental conditions and AULs. This includes helpful documents such as regulatory agency reports, permits, registrations, previous assessments, etc. • Review a commercial database summary of ASTM Standard Federal, State, and Tribal regulatory agency records pertinent to the subject property and offsite facilities located within ASTM-specified search distances from the subject property. • Review of reasonably ascertainable Federal, State, Tribal and Local environmental agency case files for onsite facilities and adjoining properties identified in the database summary report and/or during the site reconnaissance that have the potential to adversely impact the subject property. • Regulatory agency file reviews are required for the subject property and adjoining properties if identified in the environmental database. Also, reviews of previous reports/data for sites which have received "closure" is required, to verify that the closure meets current criteria and the level of closure (commercial, residential, restricted, unrestricted). Closed sites must meet residential unrestricted criteria to be a historical recognized environmental condition (HREC). • Conduct an interview with at least one staff member of any one of the following: local fire department, local health department, local building department, or State/Local environmental agency. This individual was asked about their personal knowledge of the subject property, with the questioning directed to identifying recognized environmental conditions. For example, if the site includes a known leaking underground storage tank (LUST) incident, the State agency LUST Program Project Manager for the facility may be the person interviewed under this portion of the scope of services.
• Conduct interviews with the subject property owner (or their designated Key Site Manager) and occupants regarding current and previous uses of the subject property, particularly with respect to activities involving hazardous substances and petroleum products. Past owners, operators and occupants were also interviewed to the extent they were identified and their information was not likely to be duplicative. In cases of abandoned properties, where there is evidence of uncontrolled access, this included interviews with Owners/Occupants of one or more neighboring properties (subject to availability).
• Conduct an onsite reconnaissance of the subject property for visual evidence of recognized environmental conditions, including, but not limited to: existing or potential soil and water contamination, as evidenced by soil or pavement staining or discoloration, unnaturally stressed vegetation, or indications of waste dumping or burial; pits, ponds, or lagoons; containers of hazardous substances or petroleum products; electrical and hydraulic equipment that may contain polychlorinated biphenyls (PCBs), such as electrical transformers and hydraulic hoists; underground and aboveground storage tanks (USTs and ASTs, respectively); etc. • A determination of the sources of water, power, and sewer service at the subject property. • Perform a subject property line visual reconnaissance of adjacent properties for evidence of potential offsite environmental conditions that may affect the subject property. • Evaluate information gathered during the Assessment to reach conclusions concerning recognized environmental conditions and prepare this report.

This Assessment did not include considerations of “Non-ASTM” issues (e.g., asbestos-containing building materials, radon, lead-based paint).

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
4

Page 1025 of 1828 ends

An Apex representative, Jennifer Woods, Associate Consultant III, conducted the site walkthrough portion of the Assessment on June 2, 2021, accompanied by Mr. Craig Auzenne, the Senior Maintenance Technician with TT Electronics. This Assessment was performed by (or under the responsible charge of) an Environmental Professional as defined in §312.10 of 40 CFR 312 (see Section 11.0).

Copies of selected relevant documents and supporting information are included in the applicable appendices. See the Table of Contents for a list of Appendices. Resumes for assessors and Environmental Professionals involved in this Assessment are included in the Appendices. Photographs taken at the time of the walkthrough are included behind the Photographs Tab.

1.3 Reliance
The information and opinions rendered in this report are exclusively for use by PS Southern California One, Inc., a Delaware corporation; Public Storage, a Maryland real estate investment trust, and its affiliates.

Apex will not distribute or publish this report without consent except as required by law or court order.

The information and opinions expressed in this report are given in response to a limited assignment and should be considered and implemented only in light of that assignment. The services provided by Apex in completing this project were consistent with normal standards of the profession. No other warranty, expressed or implied, is made.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
5

Page 1026 of 1828 ends

2.0 SUBJECT PROPERTY DESCRIPTION
A description of the current uses and improvement(s) (if any) at the subject property is presented in the following table(s):

Property Summary
Subject Property Address/Parcel Number: 1330 East Cypress Street, Covina, California APN: 8427-001-006
Owner: TT Electronics Power Solutions (US) Inc.

Property Size (approximate): 2.26 acres
Zoning: Zone M-1: Light Manufacturing Zone
Current Site Use: Circuit Board Manufacturing
Access/Egress: Access can be gained from East Cypress Street to the north.

Unimproved Areas: None
Landscaped Areas: Small landscaped planters containing trees are located throughout the subject property parking
lot.

2.1 Building Description
A description of the current buildings at the subject property is presented in the following tables:

Building Summary
Building Name: Building 1
Number of Floors: Single-story
Total Square Feet of Space (approximate): 23,800
Construction Completion Date (year): 1977
Heating Type: Electric
Current Tenant(s): TT Electronics
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
6

Page 1027 of 1828 ends

Building Summary
Current Use(s): Circuit Board Manufacturing
Utilities
Water: City of Covina
Wastewater/Sewer: City of Covina
Natural Gas: SoCal Gas
Electrical: Southern California Edison
Building Summary
Building Name: Building 2
Number of Floors: Two
Total Square Feet of Space (approximate): 36,200
Construction Completion Date (year): early 1980s
Heating Type: Electric
Current Tenant(s): TT Electronics
Current Use(s): Circuit Board Manufacturing
Utilities
Water: City of Covina
Wastewater/Sewer: City of Covina
Natural Gas: SoCal Gas
Electrical: Southern California Edison

2.2 Site Reconnaissance
The subject property was assessed on foot. At the time of the walkthrough, the subject property was developed with two adjoining buildings in the center of the property that were occupied by TT Electronics.

Building 1 (western building) and the first floor of Building 2 (eastern building) are primarily utilized for Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
7

Page 1028 of 1828 ends

manufacturing, assembly, equipment repair, packing, shipping, and quality control of circuit boards for defense industry purposes. Equipment utilized in these processes include UV ovens/coating machines, environmental quality control chambers (e.g., heat stress and vibration chambers), a furnace, cleaning machines, and soldering machines. The second floor of Building 2 is utilized primarily for offices, storage, and an inactive laboratory. Two hazardous materials sheds, cooling towers, and a loading dock are located to the south of Building 1. Additionally, a liquid nitrogen AST and underground clarifier are located to the west of Building 1. Telecommunication antennas with associated equipment are located on the roof of Building 2. The remainder of the subject property consists of asphalt-paved parking lots and small landscaped planters. Access can be gained from East Cypress Avenue to the north.

It should be noted that photographs could not be taken in production areas of the facility since manufactured materials are primarily for defense industry purposes.

The following site conditions were observed:

Issue Observed Comments
Stained Soil/Surface No
Distressed Vegetation No
Odors No
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
8

Page 1029 of 1828 ends

Issue Observed Comments
Chemical/Hazardous
Materials Storage
Yes Hazardous materials observed onsite during the site reconnaissance were as follows:
• One 1,500-gallon liquid nitrogen tank to the
west of the buildings.
• Approximately 30 one liter coating lab packs
located within flammable cabinets located in
the production area and the hazardous
materials shed.
• Various retail-sized containers of paints,
adhesives, acetone, isopropyl alcohol, and
cleaning chemicals located in the flammable
cabinets throughout the property.
• One 55-gallon drum of spent acetone in the
hazardous materials shed.
• One 55-gallon drum of oily debris in the
hazardous materials shed.
• One 55-gallon drum of ink cartridges in the
hazardous materials shed.
• One 55-gallon drum of shipping foam
packaging residue in the hazardous materials
shed.
• One 55-gallon drum of SMT stencil cleaner
with rinse water in the hazardous materials
shed.
• Approximately 15 one gallon containers of
detergent in the hazardous materials shed.
• Two 55-gallon drums of oily water in the
hazardous materials shed.
• Several accumulation containers located in
the production area and contain waste lead
solder and waste wiring.

All containers were observed in good condition with no
evidence of leaks or staining.

Unidentified Drums/
Substance Containers
No
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
9

Page 1030 of 1828 ends

Issue Observed Comments
Wastewater Yes Wastewater from the subject property originates from sinks, showers, and toilets and is discharged to
the municipal sewer system. Additionally, wastewater
from the cleaning machines and cooling towers are
discharged to a clarifier prior to being discharged to
the municipal sewer system.

Stormwater Yes The storm water runoff from the subject property flows via sheet flow and storm drains located throughout the
parking lot into a concrete drainage ditch along the
south side of the property.

Leachfields/Septic Tank No
Sumps/Floor Drains Yes A sump is located at the base of the loading dock and is used to pump stormwater from the loading dock into
the asphalt-paved parking lot to the east of the loading dock. No floor drains were observed.

Wells No
Waste Handling and
Disposal
Yes Currently, non-hazardous solid waste is generated
onsite. Waste is in the form of general refuse (e.g.,
paper, household trash) that is disposed of in
dumpsters located to the south of Building 2.

Additionally, hazardous waste is generated onsite and
consists of universal waste, oily water, SMT stencil
cleaner with rinse water, shipping foam packaging
residue, lead solder, oily debris, and spent acetone.

Hazardous waste is primarily stored within concrete
bermed sheds to the south of Building 1 in 55-gallon
drums and five-gallon containers. Additionally, small
containers containing hazardous waste were located
throughout the production area for daily accumulation.

These containers are transferred to the sheds once
full. All containers were observed in good condition
with no leaks or staining. Hazardous waste is picked
up on an as need basis by World Wide Recovery.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
10

Page 1031 of 1828 ends

Issue Observed Comments
Potential
PCB-Containing
Equipment
Yes One pad-mounted transformer is located to the south of Building 2. Additionally, one hydraulic elevator is
located in the onsite building. All equipment was
observed in good condition with no evidence of leaks
or staining.

Clarifier Yes One 750-gallon clarifier is located along the west side of Building 1. The clarifier is utilized for wastewater originating from the two cleaning machines and
cooling towers prior to being discharged to the
municipal sewer system. Hazardous substances are
not discharged into the clarifier. The clarifier is
inspected once per year by the City of Covina. Apex
has not received inspection records as of the date of
this report.

Aboveground Storage
Tanks (ASTs)
Yes One 1,500-gallon liquid nitrogen AST is located to the west of Building 1 on a concrete pad. No secondary
containment was observed. The AST was observed in
good condition with no leaks or staining.

Underground Storage
Tanks (USTs)
No

2.3 Physical Setting
The subsurface conditions under the subject property are interpreted from available data and may vary.

Estimated groundwater flow direction is based on topography and nearby water features unless otherwise noted. Topography is not always a reliable basis for predicting groundwater flow direction. The local groundwater gradient under the subject property may be influenced naturally by zones of higher or lower permeability, or artificially by nearby pumping or recharge, and may deviate from the regional trend.

General information on the topography, surface water, soils, bedrock and groundwater in the vicinity of the subject property is as follows:

Soil Type Urban land-Palmview-Tujunga complex, 0 to 5 percent slopes (websoilsurvey.nrcs.usda.gov).

Bedrock (Type and Depth) Quaternary alluvium and marine deposits (ERIS, 2021).

Nearby Surface Water/
Drainage Features
San Dimas Wash is approximately 4,357 feet north of the subject property (Google image).

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
11

Page 1032 of 1828 ends

Estimated Depth Shallow
Groundwater:

Groundwater is anticipated to be greater than 50 feet below ground surface (bgs) in the vicinity of the subject property
(www.geotracker.waterboards.ca.gov).

Estimated Shallow
Groundwater Flow Direction
Southwest (www.geotracker.waterboards.ca.gov).

2.4 Current Uses of Adjoining/ Nearby Properties
The area surrounding the subject property consists of commercial, residential, and light industrial development. Adjoining and nearby properties were observed (from the subject property or from public access areas) for evidence of potential recognized environmental conditions and their potential to pose an environmental concern to the subject property (Figure 1, Figures Tab). The uses and features of adjoining properties are described below (by relative compass direction and across adjoining roadways):

Direction Name Address
Type / Relevant
Observations
North Single-Family Residences
and Sports Field for Charter
Oak High School
1329-1335 Cypress Street
and 1430 East Covina
Boulevard
Residential & Institutional/
No concerns noted.

East Sunny Components Inc. 1370 Cypress Street Light Industrial/No concerns noted.

South Railroad followed by
Single-Family Residences
801-821 North Langham
Avenue
Residential/No concerns
noted.

West Covina Auto Repair & Smog
Services, HG Covina
Market, Senor Baja, Speedi
Cleaners, Domino's Pizza,
El Fino Mexican Food,
Firebird Liquors
810, 818, 826, 830, and 856
Glendora Avenue
Commercial/See Section

9.0. Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
12

Page 1033 of 1828 ends

3.0 HISTORICAL REVIEW
The following Sections detail Apex's review of available historical and related information. This includes a review of ASTM Standard Historical Sources, Agency/Department records/personnel interviews and other documents. The historical summary also incorporates information obtained from interviews and other components of the Assessment process.

3.1 Summary of Historical Review
The historical research presented in this Assessment has established the obvious uses of the subject property since 1894. In addition, information on historic uses of adjoining properties was also obtained.

A chronological summary of the historic use of the subject and adjoining/nearby properties is presented below. Please refer to the Exceptions & Limiting Conditions Section for a summary of significant data gaps (if any).

Based on historical sources, the subject property was depicted as undeveloped land from at least 1894 in the topographic maps until sometime prior to 1928 when the property was developed agriculturally and with a residence in the northwest portion. Agricultural activities ceased and the residence was demolished circa 1964. By 1977, the westernmost building on the subject property was constructed. The easternmost building was constructed circa 1983. The configuration of the subject property has not changed since that time. Tenants of the subject property have included Perkin Elmer, EG&G Power Systems, Almond Instruments, and Excilitas Technologies. TT Electronics has occupied the subject property since June 2020.

A railroad was developed on the south adjoining property from at least 1894. At that time, the remaining adjoining properties were depicted as undeveloped in the topographic map until sometime prior to 1928 when all of the adjoining properties were developed agriculturally. A residence was developed on the east adjoining property circa 1948 and the southernmost west adjoining building was developed circa 1960.

By 1960, the existing north adjoining residences and sports field were developed. Agricultural activities ceased on the remaining adjoining properties and four buildings (commercial usage and gas station) were developed on the west adjoining property circa 1964. A drycleaner has occupied the central west adjoining building since at least 1966. By 1964, the south adjoining residences were developed. An additional west adjoining commercial building and the existing east adjoining light industrial building were developed by 1972 and 1988, respectively. Between 2002 and 2009 the west adjoining gas station was demolished and the existing auto repair building was constructed.

3.2 Aerial Photographs
Aerial photographs, including the subject and adjoining properties, were obtained from ERIS - Environmental Risk Information Services for the years 1928 to 2020. Aerial photographs are summarized as follows:

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
13

Page 1034 of 1828 ends

Date Comments
1928
1938
The subject and adjoining properties were developed agriculturally. Additionally, a residential-like building was developed in the northwest portion of the subject property and a railroad was developed to the south of the subject property. 1948
1949
1952
There were no significant changes from the 1938 photograph, except that a residence was developed in the center of the east adjoining property. 1960 One small building was developed on the south portion of the west adjoining property. Agricultural activities had ceased on the north adjoining property.

Residences and a sports field were developed on the north adjoining property. No further changes were noted.
1964 Agricultural activities had ceased on the subject and remaining adjoining properties.

The residence on the subject property was demolished, leaving the property vacant.

Four additional buildings were developed on the west adjoining property.

Residences were developed on the south adjoining property. No further changes were noted.
1972 There were no significant changes from the 1964 photograph, except that an additional building was developed on the west adjoining property. 1980 There were no significant changes from the 1972 photograph, except that one building was developed on the west portion of the subject property. 1988
1995
A building was developed on the east portion of the subject property. The east adjoining residence was demolished and replaced with one larger building. No further changes were noted.
2002
2005
There were no significant changes from the 1995 photograph, except that two of the structures on the north portion of the west adjoining property were demolished. 2009
2010
2012
2014
2016
2018
2020
There were no significant changes from the 2005 photograph, except that the northernmost building on the west adjoining property was demolished and replaced with a slightly larger building.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
14

Page 1035 of 1828 ends

3.3 Topographic Maps
Topographic maps, including the subject and adjoining properties, were obtained from ERIS - Environmental Risk Information Services for the years 1894 to 2015. Topographic maps are summarized as follows:

Date Comments
1894
1897
1898
1904
1927
No structures or improvements were depicted on the subject and adjoining properties with the exception of a railroad on the south adjoining property. 1954 The subject and adjoining properties were depicted as agricultural land and a small structure was depicted on the east adjoining property. No further changes were noted.
1966
1972
1981
Agricultural land was no longer depicted on the subject and adjoining properties.

Additional structures were depicted on the west adjoining property. Charter Oak High School was depicted on the east portion of the north adjoining property. The west portion of the north adjoining property and the south adjoining property were shaded in pink, indicating an urban area.
2015 Individual structures were no longer depicted on the map.

3.4 Fire Insurance Maps
Sanborn fire insurance maps were not available for the area of the subject property, according to ERIS. A copy of the "No Coverage" letter is included in the Appendices.

3.5 City Directories
City directories covering the subject property and adjoining properties were obtained from ERIS - Environmental Risk Information Services for the period between 1931 and 2020 City directories are summarized as follows:

Address Year Occupant Listing
Subject Property
1330 East Cypress Street 1979-1986 Almond Instruments
1990-1991 Almond Instruments, EG&G Almond
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
15

Page 1036 of 1828 ends

Address Year Occupant Listing
1994-2001 EG&G Power Systems
2006-2012 Perkin Elmer Optoelectronics
2013-2020 Excelitas Technologies Corp.

Adjoining Properties
1370 East Cypress Street
(E)
1986 Hurley Thos B Jr.
1994-1995 Aire RE, Economy Processer Service
2000-2001 Advantage Construction & Maintenance, Classic Wood Works, Corona Vista Construction
2016-2020 Sunny Components
1329-1335 East Cypress
Street (N)
1986-2006 Private Residences
810 Glendora Avenue (W) 1990-2020 Firebird Liquors
818 Glendora Avenue (W) 1979 Peach Garden
1986 PJs Kountry Kitchen
1990-1991 Back Street Cafe
1994-1995 Chat & Choo
2000-2001 Sandors Place
2006 Decades Diner
2012-2016 Flavor Lounge
2020 El Fino Lounge
826 Glendora Avenue (W) 1966-1971 Checkmate Tavern
1975 The Dirty Shirt
1979 Sidepocket
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
16

Page 1037 of 1828 ends

Address Year Occupant Listing
1990-2020 Domino's Pizza
830 Glendora Avenue (W) 1966-1971 Vic's Cleaners
1975-1979 Charmay Cleaners
1986-2020 Speedy Cleaners
856 Glendora Avenue (W) 1979 Sam's Union
1986-1995 Glendora & Cypress 76
2006-2020 Covina Auto Repair & Service

3.6 Recorded Land Title Records
Information (if any) provided to Apex by the User with respect to environmental liens or AULs is discussed in Section 4.0. It should be noted that the ASTM Standard recommends that the User retain a title company or title professional to undertake a review of recorded land title records.

3.7 Agency Contacts
Apex contacted the Covina City Clerk, Los Angeles County Fire Department, South Coast Air Quality Management District, Los Angeles County Public Works Department, and Regional Water Quality Control Board, on May 26, 2021 to request information on the subject property. Information was requested with respect to historic use and various environmental-related issues, such as: permits, use of or complaints/ spills/violations involving hazardous substance and petroleum products, USTs, ASTs, etc. In addition, interviews were also conducted with available agency personnel. Interviews requested relevant personal knowledge regarding the past history of use of, and/or potential recognized environmental conditions associated with, the subject property.

Permits and records on file for the subject property are summarized as follows:

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
17

Page 1038 of 1828 ends

Agency Name
Date
Responded
Records
Available Comments
Covina City Clerk 05/27/21 Yes
• 10/27/1977 - A permit to add
approximately 8,000 square feet of
office space. The owner was listed
as Almond Instruments.
• 11/14/1977 - A permit to connect to
the municipal sewer system. The
owner was listed as Almond
Instruments.
• 12/15/1984 - A permit to change the
building use to manufacturing
operations.
• 7/20/1992 - A permit to install a
concrete foundation for one
1,500-gallon nitrogen tank. The
owner was listed as EG&G Almond
Instrument.
• 1/5/1993 - A permit to expand the
old lobby and add in a
storefront-type entrance. The owner
was listed as EG&G Power
Systems.
• 11/12/1998 - A permit to reroof the
buildings onsite. The owner was
listed as EG&G Power Systems.
• 11/7/2001 - A permit to install
roof-mounted antennas for a
telecommunications facility. The
owner was listed as Perkin Elmer.
• 1/10/2013 - A permit to install one
750-gallon clarifier along the west
side of the building. The owner was
listed as Lumen Technologies.
• 4/20/2020 - A permit to make
modifications to the existing
telecommunications facility. The
owner was listed as Lumen
Technologies.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
18

Page 1039 of 1828 ends

Agency Name
Date
Responded
Records
Available Comments
Los Angeles County Fire
Department
06/02/21 Yes
• Several Inspection Forms for
2000-2020. All violations are listed
in Section 6.0 and were corrected in
a timely manner. The most recent
inspection conducted in August
2020 did not note any violations.

Regional Water Quality
Control Board
06/07/21 Yes
• 8/10/2020 - A notice of intent permit
to discharge stormwater associated
with industrial activity for TT
Electronics.

Los Angeles County
Public Works Department
05/26/21 Yes
• 4/19/2000 - A Hazardous Materials
Storm Water System Inspection
Form for Perkin Elmer. No violations
were identified.
• 3/1/2001- A Hazardous Materials
Storm Water System Inspection
Form for Perkin Elmer. No violations
were identified; however, the
property was instructed to clean a
clogged storm drain near the
loading dock.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
19

Page 1040 of 1828 ends

Agency Name
Date
Responded
Records
Available Comments
South Coast Air Quality
Management District
05/28/21 Yes
• 9/3/1982 - A permit to operate a
degreaser that utilized organic
solvents. The owner was listed as
EG&G Almond Instruments.
• 10/4/1983 - A permit to operate a
spray booth owned by EG&G
Almond Instruments.
• 1/31/1985 - A permit to operate a
degreaser that utilized organic
solvents. The owner was listed as
EG&G Almond Instruments.
• 1/7/1988 - A permit to operate a
degreaser that utilized organic
solvents. The owner was listed as
EG&G Almond Instruments.
• 1/25/1990 - A permit to operate a
degreaser that utilized organic
solvents. The owner was listed as
EG&G Almond Instruments.
• 10/28/1992 - A permit to operate a
wave soldering machine owned by
EG&G Power System.
• 4/23/1993 - A permit to operate a
degreaser that utilized cleaning
solvents. The owner was listed as
EG&G Power System.
• 3/1/2010 - A notification to remove
asbestos-containing tile from the
lobby, hallway, and six restrooms.

The owner was listed as Perkin
Elmer.
• 3/1-3/2011 - A permit to operate a
soldering machine, solder reflow
oven, and spray booth owned by
Excelitas Technologies.
• 2/14/2020 - A permit to operate a
spray booth, soldering machine, and
solder reflow oven owned by TT
Electronics Power Solutions.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
20

Page 1041 of 1828 ends

3.8 PREVIOUS ENVIRONMENTAL REPORTS OR OTHER DOCUMENTS
Apex made requests to the client and the current property owner/site contact regarding the presence of previous environmental reports or other relevant documents for the subject property (e.g., previous Phase I or Phase II ESA, geotechnical report, MSDS, etc.).

The following previous environmental reports or other relevant documents were available for review during this Assessment:

Draft Phase I Environmental Site Assessment, Excelitas Technologies Corporation, 1330 East Cypress Street, Covina, California; dated August 19, 2019; prepared by ERM; prepared for TT Electronics.

At the time of this Assessment, the subject property was developed with two buildings occupied by Excelitas Technologies on 2.26 acres of land. Excelitas Technologies utilizes the property for the design, development, and manufacture photonic components, modules, and systems for the defense industry.

Operations generally include of mechanical and electrical assembly of metal components. Soldering and minor painting operations occur onsite within a designated spray booth. Two hazardous waste/material storage sheds are located to the south of the buildings. Hazardous materials onsite included paint, various gases, isopropanol alcohol, acetone, chemical wipes, metal clippings, and lead solder. Additionally, two resin beds were located to the west of the buildings to deionize meniscal water for the aqueous cleaning operations. No USTs or other inground equipment were noted during the site reconnaissance with the exception of a clarifier utilized for wastewater.

Based on historical sources, the subject property was originally developed for agricultural purposes with small residential and/or farm-related structures by at least 1928. By 1964, the property had been cleared and by 1977 one of the onsite buildings was constructed. The remaining building was constructed circa 1983. Tenants onsite have generally utilized the property for light industrial purposes; however, former operations onsite have included degreasing operations using chlorinated solvents (late 1970s-early 1990s) and magnetic coating operations (ceased in 2014). Limited information was available regarding degreasing operations; however, the onsite contact indicated that the reported quantity of historic chlorinated solvents remained below 55-gallons at a time. Magnetic coating operations were conducted under a hood to ensure proper ventilation; however, VOCs were likely emitted into the air.

No evidence of a recognized environmental condition was identified during this assessment; however, de minimis staining was noted on the epoxy-coated concrete floors in the hazardous materials shed. The historic operations at the property, possible asbestos-containing materials and polychlorinated biphenyls onsite due to the age of the buildings, and the west adjoining property (utilized as a gas station, auto repair, and drycleaners currently and historically) were considered "Other Potential Issues"; however, no recommendations were given.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
21

Page 1042 of 1828 ends

4.0 USER PROVIDED INFORMATION
ASTM E1527-13 defines “User” as the party seeking to use Practice E1527 to complete an environmental site assessment of the subject property. Apex understands that PS Southern California One, Inc., a Delaware corporation; Public Storage, a Maryland real estate investment trust, and its affiliates is the User as defined by ASTM E1527-13. ASTM E1527-13 specifies that certain tasks associated with identifying potential recognized environmental conditions at the subject property should be performed by the User and provided to the Environmental Professional (i.e., User Responsibilities). Accordingly, Apex provided the User a questionnaire, requesting specific information (see Appendices). Public Storage has not completed the User questionnaire as of the date of this report; however, title documents and previous reports were provided.

Based on Apex's review of the User provided information, the following information was found:

User Provided Information
Issue
Identified Comments
Title Records No The owner of the subject property is TT Electronics Power Solutions (US) Inc..

Environmental Liens or
Activity and Use Limitations
No No information provided.

Commonly Known or
Reasonably Ascertainable
Information
No No information provided.

Valuation Reduction for
Environmental Issues
No No information provided.

Previous Reports Yes See Section 3.8.

Owner, Property Manager
and Occupant Information
No No information provided.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
22

Page 1043 of 1828 ends

5.0 INTERVIEWS
Apex interviewed selected individuals associated with the subject property. The purpose of the interview(s) was to obtain additional information related to 1) the current and past operations at the subject and/ or adjoining properties that may result in recognized environmental conditions, and 2) the presence of Proceedings Involving the Property (e.g., litigation, regulatory agency rulings, violations, etc.).

5.1 Interview with Manager
Apex interviewed Mr. Craig Auzenne, the Senior Maintenance Technician with TT Electronics, on June 2, 2021, during the site reconnaissance. Mr. Auzenne provided general information regarding current operations at the subject property and indicated that TT Electronics acquired business operations at the subject property in June 2020. Mr. Auzenne is unaware of environmental issues of concern associated with the subject property, and stated that he was unaware of USTs historically or currently located on the subject property with the exception of the wastewater clarifier located onsite. Mr. Auzenne indicated that the City of Covina is responsible for inspecting and sampling the clarifier wastewater on an annual basis.

Mr. Auzenne provided additional information that is incorporated into appropriate sections of this report.

5.2 Interviews with Others
Previous owners were not interviewed during this assessment, because adequate information was obtained from other sources during this assessment.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
23

Page 1044 of 1828 ends

6.0 STANDARD ENVIRONMENTAL RECORDS SOURCES: FEDERAL, STATE,

AND TRIBAL
Available government database information prepared by ERIS - Environmental Risk Information Services was reviewed to evaluate both the subject property and listed sites within ASTM-recommended search distances. This included ASTM Standard Federal, State, and Tribal databases and may also include other types of records, subject to availability (e.g., local lists).

The regulatory database report also included an Unmappable Sites Section. Unmappable sites are sites that cannot be plotted with confidence, but can be located by zip code or city name. In general, a site cannot be geocoded due to inaccurate or missing information in the environmental database record provided by its applicable agency. Unmappable sites that were identified by Apex are included, as applicable, within the following paragraphs.

The subject property was identified in the RCRA TSD, RCRA SQG, FINDS/FRS, LA HMS, Haznet, Hist Manifest, Emissions, LA County CUPA, TRIS, RCRA NonGen, and CERS Haz databases reviewed as Excelitas Technologies Corp, EG&G Power Systems, EG&G Almond Instruments, Perkin Elmer, T-Mobile West, and TT Electronics Power Solutions. The subject property was identified in the FINDS/ FRS database as having an industrial storm water permit, being a hazardous waste generator, and being a hazardous air pollutant. The Cers Haz database indicated that several violations are on file for the subject property between 2000 and 2018. Violations have included inaccurate hazardous material inventory, failure to submit notification for onsite waste treatment, inaccurate CUPA submittal, and failure to maintain hazardous waste manifests. All violations were returned to compliance and were generally involving administrative matters.

According to the Haznet and Hist Manifest databases, the subject property has disposed of various amounts of aqueous solution with total organic residues less than 10 percent, off-specification/aged/ surplus inorganics, metal sludge, other inorganic solid waste, halogenated solvents, oxygenated solvents, unspecified solvent mixture, waste/mixed oil, unspecified oil-containing waste, polychlorinated biphenyls and material containing PCBs, polymeric resin waste, latex waste, unspecified organic liquid mixture, laboratory waste chemicals, empty containers less than 30 gallons, liquids with mercury, liquids with halogenated organic compounds, acidic liquids, other organic solids, and unspecified aqueous solution between 1982 and 2015. No further violations or evidence of a release were identified at the subject property.

A total of 62 listed sites and zero unmappable sites were identified in the databases reviewed.

The database information reviewed did indicate the presence of adjoining and/or nearby facilities within ASTM-recommended search distances of the subject property. However, it is Apex's opinion these facilities do not represent a significant threat of impact to the subject property. This opinion is supported by one or more of the following: intervening distance and/or orientation relative to the subject property; surface topography; known or suspected groundwater flow direction; regulatory status (e.g., only hold an operating permit [which does not imply a release], have been issued “No Further Action” status by the appropriate regulatory agency); and/or other available information. Accordingly, based on available information, it is Apex's opinion these facilities do not represent a recognized environmental condition, as defined by ASTM, with respect to the subject property.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
24

Page 1045 of 1828 ends

The following site was evaluated in greater detail:
• 76 Products Station #5012/Union Oil Service Station/Covina Auto Repair & Service, located at 856 Glendora Avenue, is the west adjoining downgradient property. The site was identified in the LUST, LA HMS, HHSS, Haznet, FINDS/FRS, Hist Tank, LA County CUPA, and UST Sweeps databases reviewed. The site formerly operated as a gas station with two gasoline and one waste oil USTs with an industrial waste permit. All USTs were installed in 1963 and were of single-walled carbon steel construction. A release was discovered during the removal of the USTs on March 16, 1990 and affected soil only. The incident received closure as of June 18, 1991. No further information was identified regarding the UST incident. This site is currently operating as an auto repair facility. Since this site immediately adjoins the subject property and closure was received, this is considered a historic recognized environmental condition.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
25

Page 1046 of 1828 ends

7.0 TIER 1 VAPOR ENCROACHMENT SCREEN (VES)
Apex conducted a Tier 1 VES during the Phase I ESA. The VES was conducted in accordance with ASTM E2600-15, Standard Guide for Vapor Encroachment Screening on Property Involved in Real Estate Transactions. The methods and terms are as defined in the ASTM standard.

The goal of a VES is to identify a vapor encroachment condition (VEC) at a subject property. A VEC is defined as the presence or likely presence of chemicals of concern (COC) vapors in the subsurface of a subject property caused by the release of vapors from contaminated soil or groundwater either on or near the subject property.

Information was obtained with respect to the following: planned additional structures; and significant natural or man-made “preferential pathways” of potential vapor migration. This information is summarized below:
• No information was provided on plans for the construction of additional buildings. The planned use for the subject property is development as a self storage facility. • The subject property is connected with several types of utilities, each of which has underground utility conduits.
• Based on available information soil was found to be Urban land-Palmview-Tujunga complex, 0 to 5 percent slopes and groundwater was found to be greater than 50 feet bgs.

7.1 Tier 1 Screen Evaluation
An evaluation of that information includes two tests: 1) a search distance test to evaluate the proximity of the target property to known or suspected “contaminated properties”, and 2) a chemicals of concern test to determine the likely presence of COCs at the subject or properties within the area of concern (AOC).

In evaluating the data, the distance and proximity to potentially contaminated offsite properties must be evaluated, including whether they are up-, cross-, or down-gradient relative to the subject property. A brief summary of relevant information considered for the Tier 1 screening follows:

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
26

Page 1047 of 1828 ends

Location of
Suspect
Contaminated
Properties Type of COC
Orientation
from Subject
Property Comments
Does
VEC
exist?
1330 East
Cypress
Street
Volatile Organic
Compounds
(VOCs)
Subject Property Former operations on the subject
property have included
degreasing operations using
chlorinated solvents (late
1970s-early 1990s). Limited
information was available
regarding degreasing operations;
however, the 2019 Phase I ESA
indicated that the reported
quantity of historic chlorinated
solvents remained below
55-gallons at a time. Subsurface
sampling has never been
conducted onsite to evaluate if
there are VOC impacts.

Yes
Speedy
Cleaners
830 Glendora
Avenue
Volatile Organic
Compounds
(VOCs)
West adjoining,
downgradient
property
A drycleaners has been located
on the west adjoining property
since at least 1966. Chlorinated
solvents may have historically or
currently be used in the
drycleaning process.

Yes
76 Products
Station
#5012/ Union
Oil Service
Station/
Covina Auto
Repair &
Service
856 Glendora
Avenue
Petroleum
hydrocarbons
West adjoining,
downgradient
property
The site formerly operated as a
gas station with two gasoline and
one waste oil USTs. A release
was discovered during the
removal of the USTs on March 16,
1990 and affected soil only. The
incident received closure as of
June 18, 1991.

No

7.2 Tier 1 Screening Findings
The vapor encroachment screen process has been completed in accordance with the Standard. Based on Apex's evaluation a VEC exists at the subject property due to previous operations at the subject property involving chlorinated solvents and the west adjoining drycleaner.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
27

Page 1048 of 1828 ends

8.0 EXCEPTIONS & LIMITING CONDITIONS OF ASSESSMENT
Information for the Assessment was obtained from the sources listed in the Appendices. This information, to the extent it was relied on to form our opinion, is assumed to be correct and complete. Apex is not responsible for the quality or content of information from these sources.

8.1 Unavailable Documentation
Requested documentation regarding the subject property was made available for review.

8.2 Lack of Access / Reconnaissance Limitations
Apex did not encounter significant access or reconnaissance limitations at the subject property; however, it should be noted that photographs were not allowed to be taken in the production area due to the sensitive nature of the work (defensive industry).

8.3 Data Gaps
The ASTM Standard requires that the report identify the following: 1) obvious uses of the subject property since 1940 or first development, whichever is earlier; and 2) significant “data gaps” which affect the ability of the Environmental Professional to identify recognized environmental conditions. The report is also to include information on the sources consulted to address the data gaps.

Historical subject property ownership and/or use information was obtained for the time period 1894 to present. Based on this information, Apex has established the history of obvious uses of the subject property since 1940 or first development, whichever is earlier. No significant data gaps (or other data gaps warranting discussion) were encountered during this Assessment, except the following:

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
28

Page 1049 of 1828 ends

Type of Data
Gap
Does this affect
the ability to
identify RECs? Rationale Sources consulted
No User
Questionnaire
No Requested information
was obtained from other
sources.

Apex obtained and review the
following reasonably
ascertainable records/
information: 1) ASTM Standard
Historical Sources (except
recorded land title records), 2)
selected local environmental
records sources, 3) interviewed
local government agency
personnel, 4) interviewed the
current owner, and 5) ASTM
Standard Environmental
Records Sources (through a
commercially available
database).

Historical
source gaps
greater than 5
years
No Information from other
sources verified
historical uses of the
property.

Apex obtained and reviewed the
following reasonably
ascertainable records/
information: 1) ASTM Standard
Historical Sources (except
recorded land title records), and
2) selected local environmental
records sources.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
29

Page 1050 of 1828 ends

9.0 FINDINGS AND OPINIONS
This section presents a summary of available information on known or suspected recognized environmental conditions, historical recognized environmental conditions and de minimis conditions (if any) at the subject property. It also includes Apex's opinion and rationale for concluding that a condition is, or is not, currently a recognized environmental condition. Based on a review of the information presented in this Assessment, Apex presents the following relevant findings and opinions:
• Historical Onsite Use of Chlorinated Solvents - Tenants onsite have generally utilized the property for light industrial purposes; however, former operations on the subject property have included degreasing operations using chlorinated solvents (late 1970s-early 1990s). Limited information was available regarding degreasing operations; however, the 2019 Phase I ESA indicated that the reported quantity of historic chlorinated solvents remained below 55-gallons at a time. Approximate locations of degreasing operations were indicated in the 2019 Phase I ESA; however, the site contact during Apex's Phase I ESA was not able to confirm these locations.

All approximate locations were located within the production area. No indication of floor drains, trenches, or pits were observed within this area during the site reconnaissance. Additionally, de minimis staining was noted on the epoxy-coated concrete floors in the hazardous materials shed during the 2019 Phase I ESA. No staining was observed during Apex's site reconnaissance. The former usage of chlorinated solvents onsite is considered a recognized environmental condition. • West Adjoining Drycleaner - Speedy Drycleaners is currently located in the central building on the west adjoining property. A drycleaner has been located in that tenant space since at least 1966 based on city directory listing. The drycleaner was not identified in the database review.

There is a possibility that chlorinated solvents could have and/or are currently being utilized onsite in the drycleaning process. Based on this usage and the close vicinity to the subject property, this is considered a recognized environmental condition.
• Former West Adjoining Gas Station - 76 Products Station #5012/Union Oil Service Station/ Covina Auto Repair & Service, located at 856 Glendora Avenue, is the west adjoining downgradient property. The site was identified in the LUST, LA HMS, HHSS, Haznet, FINDS/ FRS, Hist Tank, LA County CUPA, and UST Sweeps databases reviewed. The site formerly operated as a gas station with two gasoline and one waste oil USTs with an industrial waste permit. All USTs were installed in 1963 and were of single-walled carbon steel construction. A release was discovered during the removal of the USTs on March 16, 1990 and affected soil only. The incident received closure as of June 18, 1991. No further information was identified regarding the UST incident. This site is currently operating as an auto repair facility. Since this site immediately adjoins the subject property and closure was received, this is considered a historic recognized environmental condition.
• Former Agricultural Use - Based on the review of historical aerial photographs, the subject property was observed in agricultural use historically. Given this usage, it is possible that pesticides and/or herbicides were once used onsite and residual amounts may remain. Based on Apex's experience in sampling soils for residual pesticides and/or fertilizers that have been applied in conjunction with normal agricultural activities and the length of time since agricultural activity occurred onsite, the likelihood that residual chemicals will be found above cleanup levels Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
30

Page 1051 of 1828 ends

is low. Based on this evaluation, it is Apex's opinion that the potential past use of pesticides and/ or fertilizers does not present a recognized environmental condition to the subject property. • Tier 1 Vapor Encroachment Screen – Apex has conducted a Tier 1 Vapor Encroachment Screen, in accordance with ASTM Standard E2600-15. The nature of former site conditions and offsite properties of potential environmental concern were noted in the databases or other information reviewed, and based on the VES, Apex believes that a vapor encroachment condition does exist due to the past uses of chlorinated solvents onsite and the west adjoining drycleaner. This VEC does represent a recognized environmental condition to the subject property.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
31

Page 1052 of 1828 ends

10.0 CONCLUSIONS AND RECOMMENDATIONS
Apex has performed a Phase I Environmental Site Assessment in conformance with the scope and limitations of ASTM Practice E1527-13 of CA21222 located at 1330 East Cypress Street in Covina, California (the “subject property”). Any exceptions to, or deletions from, this practice are described in Sections 1.2 and 1.3 of this report.

This Assessment has revealed no evidence controlled recognized environmental conditions in connection with the subject property.

The following recognized environmental conditions were identified during this Assessment:
• Historical Onsite Use of Chlorinated Solvents
• West Adjoining Drycleaner
• Tier 1 Vapor Encroachment Screen
The following historic recognized environmental condition was identified during this Assessment:
• Former West Adjoining Gas Station
Based on Apex’s review of the environmental condition of the subject property, it is recommended that soil vapor sampling be conducted onsite to assess potential contamination from the adjoining drycleaner and the past use of chlorinated solvents onsite. Due to the sensitive nature of onsite activities, sampling will likely need to be conducted around the exterior of the building.

Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
32

Page 1053 of 1828 ends

11.0 SIGNATURES
This report was prepared, under the responsible charge of the Environmental Professional noted below:

Jennifer Woods
Associate Consultant III
Health, Safety and Environmental Services
Signal Hill Regional Office
Apex Companies, LLC
Environmental Professional’s Certification:

I declare that, to the best of my professional knowledge and belief, I meet the definition of Environmental Professional as defined in §312.10 of 40 CFR 312. I have the specific qualifications based on education, training, and experience to assess a property of the nature, history, and setting of the subject property.

I have developed and performed the all appropriate inquiries in conformance with the standards and practices set forth in 40 CFR Part 312.

Shannon Gillespie
Program Manager
Health, Safety and Environmental Services
Signal Hill Regional Office
Apex Companies, LLC
June 9, 2021
Phase I Environmental Site Assessment
CA21222
1330 East Cypress Street
Covina, California
Project No. 25021-021079.00
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
33

Page 1054 of 1828 ends

12.0 SOURCES AND REFERENCES
Documents & Previous Reports Reviewed
ASTM International, “Standard Guide for Vapor Encroachment Screening on Property Involved in Real Estate Transaction,” ASTM Designation E2600-15
ASTM International, "Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process," ASTM Designation E1527-13
Radius Map Report, ERIS, Inc.

City Directories, obtained from ERIS: 1931 through 2020 Aerial photographs, obtained from ERIS: 1928 through 2020 Historic topographic maps, obtained from ERIS: 1894 through 2015 Fire insurance maps, not available from ERIS
Draft Phase I Environmental Site Assessment, Excelitas Technologies Corporation, 1330 East Cypress Street, Covina, California; dated August 19, 2019; prepared by ERM; prepared for TT Electronics.

Persons/Agencies Contacted
Person/Agency Contacted Contact Information Date Contacted Covina City Clerk [email protected] 05/25/21
Los Angeles County Fire
Department
www.fire.lacounty.gov/ 05/25/21
Regional Water Quality Control
Board
WB-RB4-PublicRecords@water
boards.ca.gov
05/25/21
Los Angeles County Public
Works Department
https://dpw.lacounty.gov/epd/
CleanLA/OpenFileReview.aspx
05/25/21
South Coast Air Quality
Management District
http://www.aqmd.gov/nav/
online-services/public-records
05/25/21
Phase I Environmental Site Assessment
1330 East Cypress Street, Covina, California
Public Storage
June 9, 2021
34

Page 1055 of 1828 ends

Site Plan

Page 1056 of 1828 ends

SUBJECT

PROPERTY
PORTION OF 7.5-MINUTE
(TOPOGRAPHIC) MAP

UNITED STATES DEPARTMENT OF THE INTERIOR

GEOLOGICAL SURVEY

SCALE NOT TO SCALE SITE LOCATION
CA21222
1330 EAST CYPRESS STREET

COVINA, CALIFORNIA
PRJ NO. 25021-021079.00
DATE JUNE 2, 2021 1

SAN DIMAS, CA QUADRANGLE
(2015) N
FIGURE

Page 1057 of 1828 ends

Site and Vicinity Plan

Page 1058 of 1828 ends

SCALE NOT TO SCALE SITE VICINITY
CA21222
1330 EAST CYPRESS STREET

COVINA, CALIFORNIA
PRJ NO. 25021-021079.00
DATE JUNE 2, 2021 2
N
LEGEND

SUBJECT PROPERTY BOUNDARY

RESIDENTIAL

COVINA AUTO
REPAIR

RESIDENTIAL
SUNNY

COMPONENTS

CHARTER OAK

HIGH SCHOOL

SPORTS FIELDS

COMMERCIAL

BUILDINGS

COMMERCIAL

BUILDING WITH
SPEEDI

CLEANERS
FIGURE

Page 1059 of 1828 ends

Photographs

Page 1060 of 1828 ends

1 View of the subject property building facing southwest. 2 View of the eastern parking lot facing north.

Page 1061 of 1828 ends

3 General view of office space.
4 General view of conference rooms onsite.

Page 1062 of 1828 ends

5 View of general storage in the maintenance area.
6 View of the machine shop.

Page 1063 of 1828 ends

7 View of the inactive laboratory.
8 View of general site maintenance materials.

Page 1064 of 1828 ends

9 View of hazardous waste accumulation buckets located in the production area. 10 General view inside a flammable cabinet onsite.

Page 1065 of 1828 ends

11 View of the pad-mounted transformer facing north.
12 View of the loading dock with sump facing north.

Page 1066 of 1828 ends

13 View of the hazardous materials storage sheds facing northwest. 14 View of the interior of one of the hazardous materials storage sheds.

Page 1067 of 1828 ends

15 View of the oily water drums in the hazardous materials storage shed. 16 View of the cooling towers facing east.

Page 1068 of 1828 ends

17 View of the clarifier on the west side of the buildings facing northeast. 18 View of the liquid nitrogen AST facing northeast.

Page 1069 of 1828 ends

19 View of the stormwater drainage and south adjoining railroad facing east. 20 View of the east adjoining property facing southeast.

Page 1070 of 1828 ends

21 View of the north adjoining property facing north.
22 View of the west adjoining auto repair facility facing southwest.

Page 1071 of 1828 ends

23 View of the west adjoining commercial building facing southeast.

Page 1072 of 1828 ends

Resumes

Page 1073 of 1828 ends

Jennifer Woods

CONSULTANT III
1 • Jennifer Woods
Ms. Woods conducts Phase I Environmental Site Assessments (ESAs) for various financial, real estate, industrial, and commercial clients. Using American Society for Testing Materials (ASTM) standard practices as a guideline, Ms. Woods has conducted Phase I ESAs of industrials sites, commercial buildings, and undeveloped land throughout California, Arizona, Washington, Oregon, Nevada, Idaho, Montana, Colorado, Hawaii, and Texas. These have included performing historical research, interviewing owners, occupants, and local government officials, and generating reports. Ms. Woods also has participating in all phases of asbestos and lead projects. In addition, to assessing potential environmental conditions, Ms.

Woods participates in Phase II investigative activities, including soil sampling, groundwater sampling, and soil vapor sampling.

Education
BS, Environmental Science, University of California, San Diego (2015) Professional Registrations/Certification/Training
• Asbestos Hazard Emergency Response Act (AHERA) Building Inspector (6N10515) • Asbestos Contractor/Supervisor (5N12392)
• Asbestos Certified Site Surveillance Technician ( 17-6101) • Certified Lead Sampling Technician (28050)
• 40-Hour OSHA Hazwoper Trained
General Experience
2019 – Present Consultant III • Apex Companies, LLC
2015 – 2019 Consultant III • Bureau Veritas North America, Inc.

Project Experience
Phase I Environmental Site Assessment (ESAs)
Ms. Woods has conducted various Phase I ESAs throughout California, Arizona, Nevada, Oregon, Washington, Colorado, Hawaii, and Texas to satisfy due diligence investigations for real estate transactions, banks, real estate investment companies, developers, and property owners. Ms. Woods has conducted site inspections and investigated surrounding property usage; reviewed relevant regulatory files for investigations at the site or in the immediate area; and surveyed past site and surrounding property uses using aerial photographs, city directories, fire insurance maps, and government records.

Phase II Subsurface Investigations
Ms. Woods has conducted a variety of activities associated with Phase II Subsurface Investigations including field soil, groundwater, and soil vapor sample collection and lithology description, data quality control, and generating reports.

Asbestos and Lead Surveys
Ms. Woods has conducted a variety of asbestos and lead related services. Asbestos services include demolition to limited surveys of suspect asbestos-containing materials and air monitoring/oversight for asbestos abatement. Lead services include surveys for suspect lead paints by paint chip collection and XRF analyzer for direct readings of lead content.

Page 1074 of 1828 ends

Jennifer Woods
Consultant III
2 • Jennifer Woods
National Environmental Policy Act (NEPA)
Ms. Woods has conducted environmental assessments in Southern California in compliance with the National Environmental Protection Act (NEPA) for national telecommunication clients. Ms. Woods’ research includes consultation with several bureaus within the United States Department of Interior such as National Park Services (NPS), United States Fish & Wildlife Services and Bureau of Land Management (BLM). In addition, Ms. Woods contacts state and local agencies, federally and non-federally recognized Native American Tribes concerning religious areas, and the California Historic Preservation Office. Ms. Woods has investigated potential wildlife and wilderness preserves, wetlands, endangered or threatened species and habitats and Native American religious areas. Ms. Woods has knowledge of the Federal Communications Commission’s (FCC) Nationwide Programmatic Agreement (NPA).

Page 1075 of 1828 ends

Shannon Gillespie

PROGRAM MANAGER
1 • Shannon Gillespie
Ms. Gillespie has over 30 years of technical experience in conducting environmental assessments and currently works on a natural basis to maintain quality and consistency between offices. Ms. Gillespie supervises staff responsible for conducting Phase I Environmental Assessments and subsequent subsurface investigations and has final review of project deliverables.

She interacts with clients and is responsible for assuring report timeliness and maintaining project budgets. She prepares Phase I and subsurface investigation proposals and conducts business development.

Ms. Gillespie has coordinated, managed, and conducted Phase I Environmental Assessments of residential, commercial, and industrial properties as part of real estate transactions for due diligence investigations. The Phase I assessments include site visits to inspect current site and vicinity usage, review of relevant regulatory files for investigations at the site or in the area, personnel interviews, reviews of hazardous material and waste handling practices, identifying potential sources of contamination and asbestos-containing materials, and surveys of past site and vicinity usage.

Ms. Gillespie also reviews environmental assessment reports for financial institutions to assess business risk and assists clients in the preparation of Hazardous Materials Business Plans. Additionally, she conducts Phase II and Phase III assessments to locate and determine the extent of soil and groundwater contamination. Her responsibilities include soil boring installation, developing site-specific work plans and health and safety plans, interpreting analytical results, estimating volumes of impacted soil and groundwater, estimating remediation costs and report preparation.

Education
BS, Chemistry, Arizona State University (1986)
Professional Registrations/Certification/Training
• California Registered Environmental Assessor (REA-03582) • Certified Environmental Specialist (13564)
• OSHA 40-Hour Hazwoper
General Experience
2019 – Present Project Manager • Apex Companies, LLC
1989 – 2019 Program Manager • Bureau Veritas North America, Inc. 1988-1989 Rollins Chempak, Inc.
1987-1988 Disposal Control Service
1987 Maricopa County Landfill Department
1985 Salt River Project
Project Experience
CERCLA Preliminary Assessment – State of California Real Estate Division Ms. Gillespie prepared a CERCLA preliminary assessment for a 1,300-acre Department of Defense and California Army National Guard installation (Los Alamitos Armed Forces Reserve Center). The assessment included: a review of available files, personnel interviews, onsite and offsite reconnaissance, historical aerial photograph review and survey of potential sources of past and current contamination and contaminant sources. The preliminary assessment indicated that past and

Page 1076 of 1828 ends

Shannon Gillespie
Program Manager
2 • Shannon Gillespie
present operations at the installation had involved in use, storage, treatment, spillage, leakage, and disposal of materials and/or wastes that are now considered hazardous. These materials and wastes were used in a variety of aircraft and vehicle maintenance, fuel storage, landfilling, aircraft-washing, and other facility activities and operations. Based on this information, potential areas of concern at the installation requiring site investigation activities were identified. The Preliminary Assessment was conducted using guidelines developed by the U.S. Environmental Protection Agency (EPA), Waste Management Division, Region IX and California Department of Toxic Substances (DTSC).

The SI included twelve potential areas of concern identified in the Preliminary Assessment. The areas included two landfills, a flight line area, revetments, fuel tank farms, former rifle ranges, clarifiers, munitions bunkers, agricultural areas and a wastewater treatment plant. Investigation included the collection of air, surface water, groundwater, soil and soil vapor samples to assess the presence of various contaminants that were identified in the previous assessments. Ms.

Gillespie was an integral member of the team in the evaluation of data collected during the SI and generation of the remedial investigation work plan, health and safety plan, quality assurance project plan, and field sampling plan.

Phase I Environmental Site Assessment (ESAs) – Lending Institute Ms. Gillespie supervised the completion of a 45-site portfolio for a major lending institute to satisfy due diligence. The sites were located in California, Texas, and Arizona and required the coordination of staff from three other offices. All field work and written reports had to be completed within a four week period of time and within a tight budget. Ms. Gillespie solely maintained client contact and reviewed all deliverables prior to submittal to client. Some of the projects required subsequent Phase II investigations based on findings during the Phase I.

Phase I Environmental Site Assessment (ESAs) – Auto Manufacturing Company Ms. Gillespie conducting a Phase I ESA of a previously industrial buildings and adjacent agricultural field prior to the client purchasing properties. Based on the findings of the site inspection, a subsurface investigation was conducted simultaneous to the completion of the Phase I. The subsurface investigation had to be completed within five days and included 34 boreholes using direct push methods and over 160 samples. One report was submitted to the client that included both the Phase I and subsurface investigation.

Phase I Environmental Site Assessment (ESAs) – Cellular Communications Company Ms. Gillespie managed the completion of over 1,000 assessments for a cellular communications company since 2001 to satisfy due diligence. Completion of the project, which included Phase I ESAs and NEPA work, required the coordination of staff from five other offices. All fieldwork and written reports had to be completed within a quick turnaround and within a tight budget. Ms. Gillespie solely maintained client contact and reviewed all deliverables prior to submittal to client.

Page 1077 of 1828 ends

Aerial Photographs

Page 1078 of 1828 ends
Page 1079 of 1828 ends
Page 1080 of 1828 ends
Page 1081 of 1828 ends
Page 1082 of 1828 ends
Page 1083 of 1828 ends
Page 1084 of 1828 ends
Page 1085 of 1828 ends
Page 1086 of 1828 ends
Page 1087 of 1828 ends
Page 1088 of 1828 ends
Page 1089 of 1828 ends
Page 1090 of 1828 ends
Page 1091 of 1828 ends
Page 1092 of 1828 ends
Page 1093 of 1828 ends
Page 1094 of 1828 ends
Page 1095 of 1828 ends
Page 1096 of 1828 ends
Page 1097 of 1828 ends
Page 1098 of 1828 ends
Page 1099 of 1828 ends
Page 1100 of 1828 ends

Topographic Maps

Page 1101 of 1828 ends

Project Property:

Project No:

Requested By:

Order No:

Date Completed:

PS - Covina, CA
1330 Cypress Street
Covina CA 91724
25021-021079.00
Apex Companies, LLC
21052501639
May 25, 2021

Page 1102 of 1828 ends

Topographic Maps included in this report are produced by the USGS and are to be used for research purposes including a phase I report.

Maps are not to be resold as commercial property.

No warranty of Accuracy or Liability for ERIS: The information contained in this report has been produced by ERIS Information Inc.(in the US) and ERIS Information Limited Partnership (in Canada), both doing business as 'ERIS', using Topographic Maps produced by the USGS.

This maps contained herein does not purport to be and does not constitute a guarantee of the accuracy of the information contained herein.

Although ERIS has endeavored to present you with information that is accurate, ERIS disclaims, any and all liability for any errors, omissions, or inaccuracies in such information and data, whether attributable to inadvertence, negligence or otherwise, and for any consequences arising therefrom. Liability on the part of ERIS is limited to the monetary value paid for this report.

We have searched USGS collections of current topographic maps and historical topographic maps for the project property. Below is a list of maps found for the project property and adjacent area. Maps are from 7.5 and 15 minute topographic map series, if available.

Year Map Series

2015 7.5
1981 7.5
1972 7.5
1966 7.5
1954 7.5
1927 7.5
1904 15
1898 15
1897 15
1894 15

Page 1103 of 1828 ends

2015
Source: USGS 7.5 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): San Dimas,CA

Page 1104 of 1828 ends

1981
Source: USGS 7.5 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): San Dimas,CA

Page 1105 of 1828 ends

1972
Source: USGS 7.5 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): San Dimas,CA

Page 1106 of 1828 ends

1966
Source: USGS 7.5 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): San Dimas,CA

Page 1107 of 1828 ends

1954
Source: USGS 7.5 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): San Dimas,CA

Page 1108 of 1828 ends

1927
Source: USGS 7.5 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): Covina,CA

Page 1109 of 1828 ends

1904
Source: USGS 15 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): Pomona,CA

Page 1110 of 1828 ends

1898
Source: USGS 15 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): Pomona,CA

Page 1111 of 1828 ends

1897
Source: USGS 15 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): Pomona,CA

Page 1112 of 1828 ends

1894
Source: USGS 15 Minute Topographic Map
Order No. 21052501639
0 0.2 0.4 0.8
Miles
Quadrangle(s): Pomona,CA

Page 1113 of 1828 ends

Fire Insurance Maps

Page 1114 of 1828 ends

Project Property:

Project No:

Requested By:

Order No:

Date Completed:

PS - Covina, CA
1330 Cypress Street
Covina CA 91724
25021-021079.00
Apex Companies, LLC
21052501639
May 26, 2021
Please note that no information was found for your site or adjacent properties.

Page 1115 of 1828 ends

City Directories

Page 1116 of 1828 ends

Project Property: PS - Covina, CA
1330 Cypress Street
Covina, CA 91724
Project No: 25021-021079.00
Requested By: Apex Companies, LLC
Order No: 21052501639
Date Completed: May 28, 2021

Page 1117 of 1828 ends

Search Results Summary
Date Source Comment
2020 DIGITAL BUSINESS DIRECTORY
2016 DIGITAL BUSINESS DIRECTORY
2012 DIGITAL BUSINESS DIRECTORY
2006 HAINES
2000-2001 HAINES
1994-1995 HAINES
1990-1991 HAINES
1986 HAINES
1979 HAINES
1975 HAINES
1971 GENERAL TELEPHONE OF CALIFORNIIA
1966 GENERAL TELEPHONE OF CALIFORNIIA
1962 GENERAL TELEPHONE OF CALIFORNIIA
1950 PACIFIC DIRECTORY CO
1931 PACIFIC
May 28, 2021
RE: CITY DIRECTORY RESEARCH
PS - Covina, CA
1330 Cypress Street Covina, CA
Thank you for contacting ERIS for an City Directory Search for the site described above. Our staff has conducted a reverse listing City Directory search to determine prior occupants of the subject site and adjacent properties. We have provided the nearest addresses(s) when adjacent addresses are not listed. If we have searched a range of addresses, all addresses in that range found in the Directory are included.

Note: Reverse Listing Directories generally are focused on more highly developed areas. Newly developed areas may be covered in the more recent years, but the older directories will tend to cover only the "central" parts of the city. To complete the search, we have either utilized the ACPL, Library of Congress, State Archives, and/or a regional library or history center as well as multiple digitized directories. These do not claim to be a complete collection of all reverse listing city directories produced.

ERIS has made every effort to provide accurate and complete information but shall not be held liable for missing, incomplete or inaccurate information. To complete this search we used the general range(s) below to search for relevant findings. If you believe there are additional addresses or streets that require searching please contact us at 866-517-5204.

Search Criteria:
1250-1450 of E Cypress Street
800-875 of Glendora Avenue

Page 1118 of 1828 ends

Page: 2
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1330 EXCELITAS TECHNOLOGIES CORP...Electronic Equipment & Supplies-mfrs 1330 EXCELITAS TECHNOLOGIES CORP...Construction Companies 1330 EXCELITAS TECHNOLOGIES CORP...Federal Government Contractors 1330 EXCELITAS TECHNOLOGIES CORP...Radio Communication Equip & Systemswhls 1370 SUNNY COMPONENTS INC...Audio-visual Equipment & Supls (whls) 1370 SUNNY COMPONETS...Data Processing Software
1376 SPALIONE CARPET & LINOLEUM...Floor Laying Refinishing & Resurfacing 1376 TRUAX CO...Engineers-electrical
1400 CYPRESS AVE ANIMAL HOSPITAL...Veterinarians
1400 CYPRESS AVE ANIMAL HOSPITAL...Construction Companies 1400 CYPRESS AVE ANIMAL HOSPITAL...Animal Hospitals
1400 CYPRESS AVE ANIMAL HOSPITAL...Federal Government Contractors 1414 ELITE SPORTS APPAREL...Other Clothing Stores
1416 CERTIFIED TECHNICIAN...Plumbing Htg & Air-conditioning Contractors 1420 GENTECH COMPUTERS...Computers-wholesale
1422 ADVANTAGE CONSTRUCTION...Service Station Builders
1426 MR GEE'S BEAUTY SUPPLY...Cosmetics & Perfumes-retail 1426 MR GEE'S BEAUTY SUPPLY...Beauty Salons-equipment & Supls (whls) 2020 E CYPRESS STREET
SOURCE: DIGITAL BUSINESS DIRECTORY
803 AMERICAN WINDOW CO...Burglar Bars
803 AMERICAN WINDOW CO...Guards-door & Window
803 AMERICAN WINDOW CO...Glassauto Plate & Window & Etc 803 AMERICAN WINDOW CO...Window Replacement
809 GRAPHICS UNITED...Commercial Printing Nec (mfrs)
810 FIREBIRD LIQUORS...Convenience Stores
818 EL FINO LOUNGE...Cocktail Lounges
818 EL FINO LOUNGE...Billiard Parlors
826 DOMINO'S PIZZA...Foods-carry Out
826 DOMINO'S PIZZA...Pizza
826 DOMINO'S PIZZA...Cafes
826 DOMINO'S PIZZA...Hotels & Motels
827 SOARING USA...Printers (mfrs)
827 SOARING USA...Commercial Printing Nec (mfrs)
830 SPEEDY CLEANERS...Cleaners
832 SENOR BAJA...Restaurants
836 JAY'S MARKET...Convenience Stores
837 GLOBAL CONFERENCE ON DISASTER...Educational Service-business 837 OUR TRUCKING & TRACTOR SVC INC...Building Contractors 837 WILL CRUSHER CORP...Construction Management
856 COVINA AUTO REPAIR & SVC...Automobile Repairing & Service 2020 GLENDORA AVENUE
SOURCE: DIGITAL BUSINESS DIRECTORY

Page 1119 of 1828 ends

Page: 3
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1274 PROGRESSIVE REELS...Picture Frames-mfrs Supplies (whls) 1330 EXCELITAS TECHNOLOGIES CORP...Electronic Equipment & Supplies-mfrs 1330 EXCELITAS TECHNOLOGIES CORP...Federal Government Contractors 1370 SUNNY COMPONENTS INC...Audio-visual Equipment & Supls (whls) 1376 SPALIONE CARPET & LINOLEUM...Floor Laying Refinishing & Resurfacing 1376 TRUAX CO...Engineers-electrical
1400 CYPRESS AVE ANIMAL HOSPITAL...Animal Hospitals
1400 CYPRESS AVE ANIMAL HOSPITAL...Federal Government Contractors 1410 CALIFORNIA PALMS...Tents-retail
1414 ELITE SPORTS APPAREL...Other Clothing Stores
1416 CERTIFIED TECHNICIAN...Plumbing Htg & Air-conditioning Contractors 1420 GENTECH COMPUTERS...Computers-wholesale
1422 ADVANTAGE CONSTRUCTION...Service Station Builders
1422 BARNARD PRODUCTS INC...All Other Specialty Trade Contractors 1426 MR GEE'S BEAUTY SUPPLY...Cosmetics & Perfumes-retail 1428 JIANCHENG GAO...Nonclassified Establishments
2016 E CYPRESS STREET
SOURCE: DIGITAL BUSINESS DIRECTORY
803 AMERICAN WINDOW CO...Window Replacement
809 GRAPHICS UNITED...Lithographers (mfrs)
809 GRAPHICS UNITED...Commercial Printing Nec (mfrs)
809 GRAPHICS UNITED...Commercial Printing Nec (mfrs)
810 FIREBIRD LIQUORS...Convenience Stores
818 EL FINO LOUNGE...Cocktail Lounges
818 FLAVR LOUNGE...Restaurants
818 FLAVR LOUNGE...Bars
826 DOMINO'S PIZZA...Pizza
826 DOMINO'S PIZZA...Foods-carry Out
827 SOARING USA...Printers (mfrs)
830 SPEEDY CLEANERS...Cleaners
832 SENOR BAJA...Restaurants
836 JAY'S MARKET...Convenience Stores
837 GLOBAL CONFERENCE ON DISASTER...Educational Service-business 837 GLOBAL CONFERENCE ON DISASTER...Educational Service-business 837 OUR TRUCKING & TRACTOR SVC INC...Building Contractors 837 WILL CRUSHER CORP...Construction Management
856 COVINA AUTO REPAIR & SVC...Automobile Repairing & Service 2016 GLENDORA AVENUE
SOURCE: DIGITAL BUSINESS DIRECTORY

Page 1120 of 1828 ends

Page: 4
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1330 PERKIN ELMER OPTOELECTRONICS...Electronic Equipment & Supplies-mfrs 1376 SPALIONE CARPET & LINOLEUM...Floor Laying Refinishing & Resurfacing 1376 TRUAX CO...Engineers-electrical
1400 CYPRESS AVE ANIMAL HOSPITAL...Animal Hospitals
1410 CALIFORNIA PALMS...Tents-retail
1412 PESTCON EXTERMINATING...Pest Control
1420 GENTECH COMPUTERS...Computers-wholesale
1426 MR GEE'S BEAUTY SUPPLY...Cosmetics & Perfumes-retail 1428 JIANCHENG GAO...Nonclassified Establishments
2012 E CYPRESS STREET
SOURCE: DIGITAL BUSINESS DIRECTORY
803 AMERICAN WINDOW CO...Windows
809 GRAPHICS UNITED...Lithographers (mfrs)
810 FIREBIRD LIQUORS...Convenience Stores
818 FLAVR LOUNGE...Restaurants
826 DOMINO'S PIZZA...Pizza
827 SOARING USA...Printers (mfrs)
830 SPEEDY CLEANERS...Cleaners
832 EL TACO NAZO...Restaurants
836 JAY'S MARKET...Food Markets
837 OUR TRUCKING & TRACTOR SVC INC...Building Contractors 856 COVINA AUTO REPAIR & SVC...Automobile Repairing & Service 2012 GLENDORA AVENUE
SOURCE: DIGITAL BUSINESS DIRECTORY

Page 1121 of 1828 ends

Page: 5
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
2006 E CYPRESS STREET
SOURCE: HAINES
2006 GLENDORA AVENUE
SOURCE: HAINES

Page 1122 of 1828 ends

Page: 6
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
2000-2001 E CYPRESS STREET
SOURCE: HAINES
2000-2001 GLENDORA AVENUE - A
SOURCE: HAINES

Page 1123 of 1828 ends

Page: 7
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
2000-2001 GLENDORA AVENUE - B
SOURCE: HAINES
1994-1995 E CYPRESS STREET
SOURCE: HAINES

Page 1124 of 1828 ends

Page: 8
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1994-1995 GLENDORA AVENUE
SOURCE: HAINES
1990-1991 E CYPRESS STREET
SOURCE: HAINES

Page 1125 of 1828 ends

Page: 9
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1990-1991 GLENDORA AVENUE
SOURCE: HAINES
1986 E CYPRESS STREET
SOURCE: HAINES

Page 1126 of 1828 ends

Page: 10
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1986 GLENDORA AVENUE - A
SOURCE: HAINES
1986 GLENDORA AVENUE - B
SOURCE: HAINES

Page 1127 of 1828 ends

Page: 11
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1979 E CYPRESS STREET
SOURCE: HAINES
1979 GLENDORA AVENUE
SOURCE: HAINES

Page 1128 of 1828 ends

Page: 12
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1975 E CYPRESS STREET
SOURCE: HAINES
1975 GLENDORA AVENUE
SOURCE: HAINES

Page 1129 of 1828 ends

Page: 13
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1971 E CYPRESS STREET
SOURCE: GENERAL TELEPHONE OF CALIFORNIIA
1971 GLENDORA AVENUE
SOURCE: GENERAL TELEPHONE OF CALIFORNIIA

Page 1130 of 1828 ends

Page: 14
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com
1966 E CYPRESS STREET
SOURCE: GENERAL TELEPHONE OF CALIFORNIIA
1966 GLENDORA AVENUE
SOURCE: GENERAL TELEPHONE OF CALIFORNIIA

Page 1131 of 1828 ends

Page: 15
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com

NO LISTINGS IN RANGE
1962 E CYPRESS STREET
SOURCE: GENERAL TELEPHONE OF CALIFORNIIA

NO LISTINGS IN RANGE
1962 GLENDORA AVENUE
SOURCE: GENERAL TELEPHONE OF CALIFORNIIA

Page 1132 of 1828 ends

Page: 16
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com

NO LISTINGS IN RANGE
1950 E CYPRESS STREET
SOURCE: PACIFIC DIRECTORY CO

NO LISTINGS IN RANGE
1950 GLENDORA AVENUE
SOURCE: PACIFIC DIRECTORY CO

Page 1133 of 1828 ends

Page: 17
Report ID: 21052501639 - 5/28/2021
www.erisinfo.com

NO LISTINGS IN RANGE
1931 E CYPRESS STREET
SOURCE: PACIFIC

NO LISTINGS IN RANGE
1931 GLENDORA AVENUE
SOURCE: PACIFIC

Page 1134 of 1828 ends

--- END REPORT ---

Page 1135 of 1828 ends

Recorded Land Title Documents

Page 1136 of 1828 ends

1500 Quail Street, 3rd Floor
Newport Beach, CA 92660
Phone: (714) 289-3300
CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 1 Order No.: 00811029-021-KH1-DN1 Issuing Policies of Chicago Title Insurance Company
ORDER NO.: 00811029-021-DN1
Ticor Title Company of California
1500 Quail Street, 3rd Floor
Newport Beach, CA 92660
ATTN: Kim Hernandez
Email: [email protected]
Escrow/Customer Phone: (714) 289-3300
Title Officer: David Noble
Title Officer Phone: (714) 289-3379
Title Officer Fax: (949) 809-0676
Title Officer Email: [email protected]
PROPERTY: 1330 East Cypress Street, Covina, CA 91724

AMENDED PRELIMINARY REPORT
In response to the application for a policy of title insurance referenced herein, Ticor Title Company of California hereby reports that it is prepared to issue, or cause to be issued, as of the date hereof, a policy or policies of title insurance describing the land and the estate or interest therein hereinafter set forth, insuring against loss which may be sustained by reason of any defect, lien or encumbrance not shown or referred to as an exception herein or not excluded from coverage pursuant to the printed Schedules, Conditions and Stipulations or Conditions of said policy forms.

The printed Exceptions and Exclusions from the coverage and Limitations on Covered Risks of said policy or policies are set forth in Attachment One. The policy to be issued may contain an arbitration clause. When the Amount of Insurance is less than that set forth in the arbitration clause, all arbitrable matters shall be arbitrated at the option of either the Company or the Insured as the exclusive remedy of the parties. Limitations on Covered Risks applicable to the CLTA and ALTA Homeowner’s Policies of Title Insurance which establish a Deductible Amount and a Maximum Dollar Limit of Liability for certain coverages are also set forth in Attachment One.

Copies of the policy forms should be read. They are available from the office which issued this report.

This report (and any supplements or amendments hereto) is issued solely for the purpose of facilitating the issuance of a policy of title insurance and no liability is assumed hereby. If it is desired that liability be assumed prior to the issuance of a policy of title insurance, a Binder or Commitment should be requested.

The policy(s) of title insurance to be issued hereunder will be policy(s) of Chicago Title Insurance Company, a Florida Corporation.

Please read the exceptions shown or referred to herein and the exceptions and exclusions set forth in Attachment One of this report carefully. The exceptions and exclusions are meant to provide you with notice of matters which are not covered under the terms of the title insurance policy and should be carefully considered.

It is important to note that this preliminary report is not a written representation as to the condition of title and may not list all liens, defects and encumbrances affecting title to the land.

Countersigned:

By:

Authorized Signature

Page 1137 of 1828 ends

1500 Quail Street, 3rd Floor
Newport Beach, CA 92660
Phone: (714) 289-3300
CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 2 Order No.: 00811029-021-KH1-DN1

AMENDED PRELIMINARY REPORT
EFFECTIVE DATE: April 2, 2021 at 7:30 a.m., Amended: April 27, 2021, Amendment No. 1 ORDER NO.: 00811029-021-DN1
The form of policy or policies of title insurance contemplated by this report is:

ALTA Homeowners Policy of Title Insurance (12-2-13)
ALTA Extended Loan Policy (6-17-06)

1. THE ESTATE OR INTEREST IN THE LAND HEREINAFTER DESCRIBED OR REFERRED TO COVERED BY THIS REPORT IS:

Fee and Easement Estate

2. TITLE TO SAID ESTATE OR INTEREST AT THE DATE HEREOF IS VESTED IN:

TT Electronics Power Solutions (US) Inc., a Delaware corporation

3. THE LAND REFERRED TO IN THIS REPORT IS DESCRIBED AS FOLLOWS:

See Exhibit A attached hereto and made a part hereof.

Page 1138 of 1828 ends

PRELIMINARY REPORT Ticor Title Company of California
YOUR REFERENCE:

CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 3 Order No.: 00811029-021-KH1-DN1 EXHIBIT “A”

LEGAL DESCRIPTION

THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS:

PARCEL 1:

LOT 1 OF C. J. HEYLER TRACT, IN THE COUNTY OF LOS ANGELES, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 13, PAGE 42 OF MAPS, IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.

EXCEPT THE EASTERLY 135 FEET, MEASURED AT RIGHT ANGLES TO THE EASTERLY LINE OF SAID LOT.

ALSO EXCEPT THE WESTERLY 140 FEET, MEASURED ALONG THE NORTHERLY LINE OF SAID LOT.

ALSO EXCEPTING FROM THE REMAINDER OF SAID LAND, THAT PORTION DESCRIBED AS FOLLOWS:

BEGINNING AT THE NORTHWEST CORNER OF SAID LOT 1; THENCE SOUTHERLY ALONG THE WESTERLY LINE OF SAID LOT 1 TO THE NORTHERLY LINE OF THE SOUTHERLY 169 FEET MEASURED ALONG THE WESTERLY LINE OF SAID LOT; THENCE EASTERLY ALONG SAID NORTHERLY LINE TO THE EASTERLY LINE OF THE WESTERLY 150 FEET OF SAID LOT; THENCE NORTHERLY ALONG SAID EASTERLY LINE TO A POINT IN THE NORTHERLY LINE OF SAID LOT; THENCE WESTERLY ALONG SAID NORTHERLY LINE TO THE NORTHWEST CORNER OF SAID LOT 1.

PARCEL 2:

AN EASEMENT FOR PUBLIC UTILITY PURPOSES OVER THE SOUTHERLY 10 FEET OF THE NORTHERLY 150 FEET OF THE WESTERLY 150 FEET OF LOT 1.

APN: 8427-001-006

Page 1139 of 1828 ends

PRELIMINARY REPORT Ticor Title Company of California
YOUR REFERENCE:

CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 4 Order No.: 00811029-021-KH1-DN1

EXCEPTIONS

AT THE DATE HEREOF, ITEMS TO BE CONSIDERED AND EXCEPTIONS TO COVERAGE IN ADDITION TO THE PRINTED EXCEPTIONS AND EXCLUSIONS IN SAID POLICY FORM WOULD BE AS FOLLOWS:

1. Property taxes, which are a lien not yet due and payable, including any assessments collected with taxes to be levied for the fiscal year 2021 - 2022.

2. Property taxes, including any personal property taxes and any assessments collected with taxes, are as follows:

Tax Identification No.: 8427-001-006
Fiscal Year: 2020-2021
1st Installment: $48,828.08, paid.
2nd Installment: $48,828.06, Delinquent (Delinquent after April 10) Penalty and Cost: $4,892.80
Code Area: 02645

3. Any liens or other assessments, bonds, or special district liens including without limitation, Community Facility Districts, that arise by reason of any local, City, Municipal or County Project or Special District.

4. The lien of supplemental or escaped assessments of property taxes, if any, made pursuant to the provisions of Chapter 3.5 (commencing with Section 75) or Part 2, Chapter 3, Articles 3 and 4, respectively, of the Revenue and Taxation Code of the State of California as a result of the transfer of title to the vestee named in Schedule A or as a result of changes in ownership or new construction occurring prior to Date of Policy.

5. Water rights, claims or title to water, whether or not disclosed by the public records.

6. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document:

Granted to: County of Los Angeles
Purpose: Highway purposes
Recording Date: October 22, 1958
Recording No: 3334 of Official Records
Affects: A portion of said land as more particularly described in said document.

Reference is hereby made to said document for full particulars.

7. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document:

Granted to: County of Los Angeles
Purpose: Public road and highway
Recording Date: March 1, 1962
Recording No: 5732, Book D1529, Page 321 of Official Records Affects: A portion of said land as more particularly described in said document.

Reference is hereby made to said document for full particulars.

8. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document:

Granted to: Southern California Edison Company
Purpose: Pole lines and conduits
Recording Date: January 5, 1978
Recording No: 78-16590 of Official Records
Affects: A portion of said land as more particularly described in said document.

Page 1140 of 1828 ends

PRELIMINARY REPORT Ticor Title Company of California
YOUR REFERENCE:

EXCEPTIONS
(Continued)
CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 5 Order No.: 00811029-021-KH1-DN1 Reference is hereby made to said document for full particulars.

9. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document:

Granted to: City of Covina
Purpose: Sanitary sewers and storm drain
Recording Date: January 23, 19778
Recording No: 78-85264 of Official Records
Affects: A portion of said land as more particularly described in said document.

Reference is hereby made to said document for full particulars.

10. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document:

Granted to: Southern California Edison Company
Purpose: Public utilities
Recording Date: December 1, 1983
Recording No: 83-1416095 of Official Records
Affects: A portion of said land as more particularly described in said document.

Reference is hereby made to said document for full particulars

11. Easement(s) for the purpose(s) shown below and rights incidental thereto, as granted in a document:

Granted to: Southern California Edison Company
Purpose: Public utilities
Recording Date: November 25, 1986
Recording No: 86-1636249 of Official Records
Affects: A portion of said land as more particularly described in said document.

Reference is hereby made to said document for full particulars

12. Any rights, claims or interests that may exist or arise by reason of the following facts disclosed by a map dated December 19, 2019 of an ALTA/NSPS Land Title Survey completed October 21, 2019 prepared by or under the responsible charge of Casey Lynch LS 8380, of/for Partner Engineering and Science, Inc., Project/Job No. 19-261431.

A. There is a transformer, manholes, water valve, and fire hydrant on surveyed property.

B. The buildings on surveyed property extend onto an easement for pole lines and conduits recorded January 5, 1978 as Instrument No. 78-16590 of Official Records C. The buildings on surveyed property extend onto an easement for public utilities recorded December 1, 1983 as Instrument No. 83-1416095 of Official Records.

13. The search did not disclose any open mortgages or deeds of trust of record, therefore the Company reserves the right to require further evidence to confirm that the property is unencumbered, and further reserves the right to make additional requirements or add additional items or exceptions upon receipt of the requested evidence.

14. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other matters which a correct survey would disclose and which are not shown by the public records.

Page 1141 of 1828 ends

PRELIMINARY REPORT Ticor Title Company of California
YOUR REFERENCE:

EXCEPTIONS
(Continued)
CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 6 Order No.: 00811029-021-KH1-DN1

15. Any easements not disclosed by the public records as to matters affecting title to real property, whether or not said easements are visible and apparent.

16. Matters which may be disclosed by an inspection and/or by a correct ALTA/NSPS Land Title Survey of said Land that is satisfactory to the Company, and/or by inquiry of the parties in possession thereof.

17. Any rights of the parties in possession of a portion of, or all of, said Land, which rights are not disclosed by the public records.

The Company will require, for review, a full and complete copy of any unrecorded agreement, contract, license and/or lease, together with all supplements, assignments and amendments thereto, before issuing any policy of title insurance without excepting this item from coverage.

The Company reserves the right to except additional items and/or make additional requirements after reviewing said documents.

PLEASE REFER TO THE “INFORMATIONAL NOTES” AND “REQUIREMENTS” SECTIONS WHICH FOLLOW FOR INFORMATION NECESSARY TO COMPLETE THIS TRANSACTION.

END OF EXCEPTIONS

Page 1142 of 1828 ends

PRELIMINARY REPORT Ticor Title Company of California
YOUR REFERENCE:

CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 7 Order No.: 00811029-021-KH1-DN1

REQUIREMENTS SECTION

1. The Company will require the following documents for review prior to the issuance of any title insurance predicated upon a conveyance or encumbrance by the corporation named below:

Name of Corporation: TT Electronics Power Solutions (US) Inc., a Delaware corporation a) A Copy of the corporation By-laws and Articles of Incorporation b) An original or certified copy of a resolution authorizing the transaction contemplated herein c) If the Articles and/or By-laws require approval by a ‘parent’ organization, a copy of the Articles and By-laws of the parent
The Company reserves the right to add additional items or make further requirements after review of the requested documentation.

2. Unrecorded matters which may be disclosed by an Owner’s Affidavit or Declaration. A form of the Owner’s Affidavit/Declaration is attached to this Preliminary Report/Commitment. This Affidavit/Declaration is to be completed by the record owner of the land and submitted for review prior to the closing of this transaction. Your prompt attention to this requirement will help avoid delays in the closing of this transaction. Thank you.

The Company reserves the right to add additional items or make further requirements after review of the requested Affidavit/Declaration.

3. Furnish for review a full and complete copy of any unrecorded agreement, contract, license and/or lease together with all supplements, assignments and amendments thereto, prior to the close of this transaction.

The Company reserves the right to add additional items or make further requirements after review of the requested documentation.

4. In order to complete this report, the Company requires a Statement of Information to be completed by the following party(s),
Party(s): All Parties
The Company reserves the right to add additional items or make further requirements after review of the requested Statement of Information.

NOTE: The Statement of Information is necessary to complete the search and examination of title under this order. Any title search includes matters that are indexed by name only, and having a completed Statement of Information assists the Company in the elimination of certain matters which appear to involve the parties but in fact affect another party with the same or similar name.

Be assured that the Statement of Information is essential and will be kept strictly confidential to this file.

END OF REQUIREMENTS

Page 1143 of 1828 ends

PRELIMINARY REPORT Ticor Title Company of California
YOUR REFERENCE:

CLTA Preliminary Title Report
lPrelm (DSI Rev. 8/15/16) Page 1 Order No.: 00811029-021-KH1-DN1

INFORMATIONAL NOTES SECTION

1. Note: The only conveyance(s) affecting said Land, which recorded within 24 months of the date of this report, are as follows:

Grantor: Excelitas Technologies, Corp., a Delaware Corporation Grantee: TT Electronics Power Solutions (US) Inc., a Delaware corporation Recording Date: January 06, 2020
Recording No: 2020-10464, of Official Records

2. None of the items shown in this report will cause the Company to decline to attach ALTA Endorsement Form 9 to an Extended Coverage Loan Policy, when issued.

3. The Company is not aware of any matters which would cause it to decline to attach CLTA Endorsement Form 116 indicating that there is located on said Land Commercial properties, known as 1330 East Cypress Street, located within the city of Covina, California, 91724, to an Extended Coverage Loan Policy.

4. Note: The policy of title insurance will include an arbitration provision. The Company or the insured may demand arbitration. Arbitrable matters may include, but are not limited to, any controversy or claim between the Company and the insured arising out of or relating to this policy, any service of the Company in connection with its issuance or the breach of a policy provision or other obligation. Please ask your escrow or title officer for a sample copy of the policy to be issued if you wish to review the arbitration provisions and any other provisions pertaining to your Title Insurance coverage.

5. Notice: Please be aware that due to the conflict between federal and state laws concerning the cultivation, distribution, manufacture or sale of marijuana, the Company is not able to close or insure any transaction involving Land that is associated with these activities.

6. Pursuant to Government Code Section 27388.1, as amended and effective as of 1-1-2018, a Documentary Transfer Tax (DTT) Affidavit may be required to be completed and submitted with each document when DTT is being paid or when an exemption is being claimed from paying the tax. If a governmental agency is a party to the document, the form will not be required. DTT Affidavits may be available at a Tax Assessor-County Clerk-Recorder.

END OF INFORMATIONAL NOTES
David Noble/am2

Page 1144 of 1828 ends

Wire Fraud Alert Page 1
Original Effective Date: 5/11/2017
Current Version Date: 5/11/2017 WIRE0016 (DSI Rev. 12/07/17) TM and © Fidelity National Financial, Inc. and/or an affiliate. All rights reserved Wire Fraud Alert
This Notice is not intended to provide legal or professional advice. If you have any questions, please consult with a lawyer.

All parties to a real estate transaction are targets for wire fraud and many have lost hundreds of thousands of dollars because they simply relied on the wire instructions received via email, without further verification. If funds are to be wired in conjunction with this real estate transaction, we strongly recommend verbal verification of wire instructions through a known, trusted phone number prior to sending funds.

In addition, the following non‐exclusive self‐protection strategies are recommended to minimize exposure to possible wire fraud.
 NEVER RELY on emails purporting to change wire instructions. Parties to a transaction rarely change wire instructions in the course of a transaction.
 ALWAYS VERIFY wire instructions, specifically the ABA routing number and account number, by calling the party who sent the instructions to you. DO NOT use the phone number provided in the email containing the instructions, use phone numbers you have called before or can otherwise verify. Obtain the phone number of relevant parties to the transaction as soon as an escrow account is opened. DO NOT send an email to verify as the email address may be incorrect or the email may be intercepted by the fraudster.  USE COMPLEX EMAIL PASSWORDS that employ a combination of mixed case, numbers, and symbols. Make your passwords greater than eight (8) characters. Also, change your password often and do NOT reuse the same password for other online accounts.
 USE MULTI-FACTOR AUTHENTICATION for email accounts. Your email provider or IT staff may have specific instructions on how to implement this feature.

For more information on wire‐fraud scams or to report an incident, please refer to the following links:

Federal Bureau of Investigation: Internet Crime Complaint Center:
http://www.fbi.gov http://www.ic3.gov

Page 1145 of 1828 ends

1500 Quail Street, 3rd Floor
Newport Beach, CA 92660
Phone: (714) 289-3300
Notice of Available Discounts (Rev. 01-15-20) Last Saved: April 27, 2021 by AJ2 MISC0343 (DSI Rev. 03/12/20) Escrow No.: 00811029-021-KH1-DN1 Notice of Available Discounts
Pursuant to Section 2355.3 in Title 10 of the California Code of Regulations Fidelity National Financial, Inc. and its subsidiaries ("FNF") must deliver a notice of each discount available under our current rate filing along with the delivery of escrow instructions, a preliminary report or commitment. Please be aware that the provision of this notice does not constitute a waiver of the consumer's right to be charged the filed rate. As such, your transaction may not qualify for the below discounts.

You are encouraged to discuss the applicability of one or more of the below discounts with a Company representative. These discounts are generally described below; consult the rate manual for a full description of the terms, conditions and requirements for such discount. These discounts only apply to transactions involving services rendered by the FNF Family of Companies. This notice only applies to transactions involving property improved with a one-to-four family residential dwelling.

Not all discounts are offered by every FNF Company. The discount will only be applicable to the FNF Company as indicated by the named discount.

FNF Underwritten Title Company Underwritten by FNF Underwriters CTC – Chicago Title company CTIC – Chicago Title Insurance Company CLTC – Commonwealth Land Title Company CLTIC - Commonwealth Land Title Insurance Company FNTC – Fidelity National Title Company of California FNTIC – Fidelity National Title Insurance Company FNTCCA - Fidelity National Title Company of California FNTIC - Fidelity National Title Insurance Company TICOR – Ticor Title Company of California CTIC – Chicago Title Insurance Company LTC – Lawyer’s Title Company CLTIC – Commonwealth Land Title Insurance Company SLTC – ServiceLink Title Company CTIC – Chicago Title Insurance Company Available Discounts

DISASTER LOANS (CTIC, CLTIC, FNTIC)
The charge for a Lender's Policy (Standard or Extended coverage) covering the financing or refinancing by an owner of record, within twenty-four (24) months of the date of a declaration of a disaster area by the government of the United States or the State of California on any land located in said area, which was partially or totally destroyedin the disaster, will be fifty percent (50%) of the appropriatetitle insurance rate.

CHURCHES OR CHARITABLE NON-PROFIT ORGANIZATIONS (CTIC, FNTIC) On properties used as a church or for charitable purposes within the scope of the normal activities of such entities, provided said charge is normally the church's obligation the charge for an owner's policy shall be fifty percent (50%) to seventy percent (70%) of the appropriate title insurance rate, depending on the type of coverage selected. The charge for a lender's policy shall be forty (40%) to fifty percent (50%) of the appropriate title insurance rate, depending on the type of coverage selected.

Page 1146 of 1828 ends

FNF Privacy Statement (Eff. January 1, 2021) Copyright © 2021. Fidelity National Financial, Inc. All Rights Reserved MISC0219 (DSI Rev. 01/29/21) Page 1 Order No. 00811029-021-KH1-DN1 FIDELITY NATIONAL FINANCIAL, INC.

PRIVACY NOTICE
Effective January 1, 2021
Fidelity National Financial, Inc. and its majority-owned subsidiary companies (collectively, “FNF,” “our,” or “we”) respect and are committed to protecting your privacy. This Privacy Notice explains how we collect, use, and protect personal information, when and to whom we disclose such information, and the choices you have about the use and disclosure of that information.

A limited number of FNF subsidiaries have their own privacy notices. If a subsidiary has its own privacy notice, the privacy notice will be available on the subsidiary’s website and this Privacy Notice does not apply.

Collection of Personal Information
FNF may collect the following categories of Personal Information:
 contact information (e.g., name, address, phone number, email address);  demographic information (e.g., date of birth, gender, marital status);  identity information (e.g. Social Security Number, driver’s license, passport, or other government ID number);  financial account information (e.g. loan or bank account information); and  other personal information necessary to provide products or services to you.

We may collect Personal Information about you from:
 information we receive from you or your agent;
 information about your transactions with FNF, our affiliates, or others; and  information we receive from consumer reporting agencies and/or governmental entities, either directly from these entities or through others.

Collection of Browsing Information
FNF automatically collects the following types of Browsing Information when you access an FNF website, online service, or application (each an “FNF Website”) from your Internet browser, computer, and/or device:
 Internet Protocol (IP) address and operating system;
 browser version, language, and type;
 domain name system requests; and
 browsing history on the FNF Website, such as date and time of your visit to the FNF Website and visits to the pages within the FNF Website.

Like most websites, our servers automatically log each visitor to the FNF Website and may collect the Browsing Information described above. We use Browsing Information for system administration, troubleshooting, fraud investigation, and to improve our websites.

Browsing Information generally does not reveal anything personal about you, though if you have created a user account for an FNF Website and are logged into that account, the FNF Website may be able to link certain browsing activity to your user account.

Other Online Specifics
Cookies. When you visit an FNF Website, a “cookie” may be sent to your computer. A cookie is a small piece of data that is sent to your Internet browser from a web server and stored on your computer’s hard drive. Information gathered using cookies helps us improve your user experience. For example, a cookie can help the website load properly or can customize the display page based on your browser type and user preferences. You can choose whether or not to accept cookies by changing your Internet browser settings. Be aware that doing so may impair or limit some functionality of the FNF Website.

Web Beacons. We use web beacons to determine when and how many times a page has been viewed. This information is used to improve our websites.

Do Not Track. Currently our FNF Websites do not respond to “Do Not Track” features enabled through your browser.

Links to Other Sites. FNF Websites may contain links to unaffiliated third-party websites. FNF is not responsible for the privacy practices or content of those websites. We recommend that you read the privacy policy of every website you visit.

Use of Personal Information
FNF uses Personal Information for three main purposes:
 To provide products and services to you or in connection with a transaction involving you.  To improve our products and services.
 To communicate with you about our, our affiliates’, and others’ products and services, jointly or independently.

When Information Is Disclosed
We may disclose your Personal Information and Browsing Information in the following circumstances:
 to enable us to detect or prevent criminal activity, fraud, material misrepresentation, or nondisclosure;  to nonaffiliated service providers who provide or perform services or functions on our behalf and who agree to use the information only to provide such services or functions;

Page 1147 of 1828 ends

FNF Privacy Statement (Eff. January 1, 2021) Copyright © 2021. Fidelity National Financial, Inc. All Rights Reserved MISC0219 (DSI Rev. 01/29/21) Page 2 Order No. 00811029-021-KH1-DN1  to nonaffiliated third party service providers with whom we perform joint marketing, pursuant to an agreement with them to jointly market financial products or services to you;
 to law enforcement or authorities in connection with an investigation, or in response to a subpoena or court order; or  in the good-faith belief that such disclosure is necessary to comply with legal process or applicable laws, or to protect the rights, property, or safety of FNF, its customers, or the public.

The law does not require your prior authorization and does not allow you to restrict the disclosures described above. Additionally, we may disclose your information to third parties for whom you have given us authorization or consent to make such disclosure. We do not otherwise share your Personal Information or Browsing Information with nonaffiliated third parties, except as required or permitted by law. We may share your Personal Information with affiliates (other companies owned by FNF) to directly market to you. Please see “Choices with Your Information” to learn how to restrict that sharing.

We reserve the right to transfer your Personal Information, Browsing Information, and any other information, in connection with the sale or other disposition of all or part of the FNF business and/or assets, or in the event of bankruptcy, reorganization, insolvency, receivership, or an assignment for the benefit of creditors. By submitting Personal Information and/or Browsing Information to FNF, you expressly agree and consent to the use and/or transfer of the foregoing information in connection with any of the above described proceedings.

Security of Your Information
We maintain physical, electronic, and procedural safeguards to protect your Personal Information.

Choices With Your Information
If you do not want FNF to share your information among our affiliates to directly market to you, you may send an “opt out” request as directed at the end of this Privacy Notice. We do not share your Personal Information with nonaffiliates for their use to direct market to you without your consent.

Whether you submit Personal Information or Browsing Information to FNF is entirely up to you. If you decide not to submit Personal Information or Browsing Information, FNF may not be able to provide certain services or products to you.

For California Residents: We will not share your Personal Information or Browsing Information with nonaffiliated third parties, except as permitted by California law. For additional information about your California privacy rights, please visit the “California Privacy” link on our website (https://fnf.com/pages/californiaprivacy.aspx) or call (888) 413-1748.

For Nevada Residents: You may be placed on our internal Do Not Call List by calling (888) 934-3354 or by contacting us via the information set forth at the end of this Privacy Notice. Nevada law requires that we also provide you with the following contact information: Bureau of Consumer Protection, Office of the Nevada Attorney General, 555 E. Washington St., Suite 3900, Las Vegas, NV 89101; Phone number: (702) 486-3132; email: [email protected].

For Oregon Residents: We will not share your Personal Information or Browsing Information with nonaffiliated third parties for marketing purposes, except after you have been informed by us of such sharing and had an opportunity to indicate that you do not want a disclosure made for marketing purposes.

For Vermont Residents: We will not disclose information about your creditworthiness to our affiliates and will not disclose your personal information, financial information, credit report, or health information to nonaffiliated third parties to market to you, other than as permitted by Vermont law, unless you authorize us to make those disclosures.

Information From Children
The FNF Websites are not intended or designed to attract persons under the age of eighteen (18).We do not collect Personal Information from any person that we know to be under the age of thirteen (13) without permission from a parent or guardian.

International Users
FNF’s headquarters is located within the United States. If you reside outside the United States and choose to provide Personal Information or Browsing Information to us, please note that we may transfer that information outside of your country of residence. By providing FNF with your Personal Information and/or Browsing Information, you consent to our collection, transfer, and use of such information in accordance with this Privacy Notice.

FNF Website Services for Mortgage Loans
Certain FNF companies provide services to mortgage loan servicers, including hosting websites that collect customer information on behalf of mortgage loan servicers (the “Service Websites”). The Service Websites may contain links to both this Privacy Notice and the mortgage loan servicer or lender’s privacy notice. The sections of this Privacy Notice titled When Information is Disclosed, Choices with Your Information, and Accessing and Correcting Information do not apply to the Service Websites. The mortgage loan servicer or lender’s privacy notice governs use, disclosure, and access to your Personal Information. FNF does not share Personal Information collected through the Service Websites, except as required or authorized by contract with the mortgage loan servicer or lender, or as required by law or in the good-faith belief that such disclosure is necessary: to comply with a legal process or applicable law, to enforce this Privacy Notice, or to protect the rights, property, or safety of FNF or the public.

Page 1148 of 1828 ends

FNF Privacy Statement (Eff. January 1, 2021) Copyright © 2021. Fidelity National Financial, Inc. All Rights Reserved MISC0219 (DSI Rev. 01/29/21) Page 3 Order No. 00811029-021-KH1-DN1 Your Consent To This Privacy Notice; Notice Changes; Use of Comments or Feedback By submitting Personal Information and/or Browsing Information to FNF, you consent to the collection and use of the information in accordance with this Privacy Notice. We may change this Privacy Notice at any time. The Privacy Notice’s effective date will show the last date changes were made. If you provide information to us following any change of the Privacy Notice, that signifies your assent to and acceptance of the changes to the Privacy Notice.

Accessing and Correcting Information; Contact Us
If you have questions, would like to correct your Personal Information, or want to opt-out of information sharing for affiliate marketing, visit FNF’s Opt Out Page or contact us by phone at (888) 934-3354 or by mail to:

Fidelity National Financial, Inc.
601 Riverside Avenue
Jacksonville, Florida 32204
Attn: Chief Privacy Officer

Page 1149 of 1828 ends

Attachment One – CA (Rev. 05-06-16) Page 1
© California Land Title Association. All rights reserved.

The use of this Form is restricted to CLTA subscribers in good standing as of the date of use. All other uses are prohibited. Reprinted under license or express permission from the California Land Title Association.

ATTACHMENT ONE (Revised 05-06-16)

CALIFORNIA LAND TITLE ASSOCIATION
STANDARD COVERAGE POLICY – 1990

EXCLUSIONS FROM COVERAGE
The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys' fees or expenses which arise by reason of:

1. (a) Any law, ordinance or governmental regulation (including but not limited to building or zoning laws, ordinances, or regulations) restricting, regulating, prohibiting or relating (i) the occupancy, use, or enjoyment of the land; (ii) the character, dimensions or location of any improvement now or hereafter erected on the land; (iii) a separation in ownership or a change in the dimensions or area of the land or any parcel of which the land is or was a part; or (iv) environmental protection, or the effect of any violation of these laws, ordinances or governmental regulations, except to the extent that a notice of the enforcement thereof or a notice of a defect, lien, or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy. (b) Any governmental police power not excluded by (a) above, except to the extent that a notice of the exercise thereof or notice of a defect, lien or encumbrance resulting from a violation or alleged violation affecting the land has been recorded in the public records at Date of Policy.

2. Rights of eminent domain unless notice of the exercise thereof has been recorded in the public records at Date of Policy, but not excluding from coverage any taking which has occurred prior to Date of Policy which would be binding on the rights of a purchaser for value without knowledge.

3. Defects, liens, encumbrances, adverse claims or other matters:
(a) whether or not recorded in the public records at Date of Policy, but created, suffered, assumed or agreed to by the insured claimant; (b) not known to the Company, not recorded in the public records at Date of Policy, but known to the insured claimant and not disclosed in writing to the Company by the insured claimant prior to the date the insured claimant became an insured under this policy; (c) resulting in no loss or damage to the insured claimant; (d) attaching or created subsequent to Date of Policy; or (e) resulting in loss or damage which would not have been sustained if the insured claimant had paid value for the insured mortgage or for the estate or interest insured by this policy.

4. Unenforceability of the lien of the insured mortgage because of the inability or failure of the insured at Date of Policy, or the inability or failure of any subsequent owner of the indebtedness, to comply with the applicable doing business laws of the state in which the land is situated.

5. Invalidity or unenforceability of the lien of the insured mortgage, or claim thereof, which arises out of the transaction evidenced by the insured mortgage and is based upon usury or any consumer credit protection or truth in lending law.

6. Any claim, which arises out of the transaction vesting in the insured the estate of interest insured by this policy or the transaction creating the interest of the insured lender, by reason of the operation of federal bankruptcy, state insolvency or similar creditors' rights laws.

EXCEPTIONS FROM COVERAGE - SCHEDULE B, PART I
This policy does not insure against loss or damage (and the Company will not pay costs, attorneys' fees or expenses) which arise by reason of:

1. Taxes or assessments which are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the public records.

Proceedings by a public agency which may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the public records.

2. Any facts, rights, interests, or claims which are not shown by the public records but which could be ascertained by an inspection of the land or which may be asserted by persons in possession thereof.

3. Easements, liens or encumbrances, or claims thereof, not shown by the public records.

4. Discrepancies, conflicts in boundary lines, shortage in area, encroachments, or any other facts which a correct survey would disclose, and which are not shown by the public records.

5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b) or (c) are shown by the public records.

6. Any lien or right to a lien for services, labor or material not shown by the public records.

CLTA HOMEOWNER'S POLICY OF TITLE INSURANCE (12-02-13)

ALTA HOMEOWNER'S POLICY OF TITLE INSURANCE

EXCLUSIONS
In addition to the Exceptions in Schedule B, You are not insured against loss, costs, attorneys' fees, and expenses resulting from:

1. Governmental police power, and the existence or violation of those portions of any law or government regulation concerning:
a. building;
b. zoning;
c. land use;
d. improvements on the Land;
e. land division; and
f. environmental protection.

This Exclusion does not limit the coverage described in Covered Risk 8.a., 14, 15, 16, 18, 19, 20, 23 or 27.

2. The failure of Your existing structures, or any part of them, to be constructed in accordance with applicable building codes. This Exclusion does not limit the coverage described in Covered Risk 14 or 15.

3. The right to take the Land by condemning it. This Exclusion does not limit the coverage described in Covered Risk 17.

4. Risks:
a. that are created, allowed, or agreed to by You, whether or not they are recorded in the Public Records; b. that are Known to You at the Policy Date, but not to Us, unless they are recorded in the Public Records at the Policy Date;

Page 1150 of 1828 ends

Attachment One – CA (Rev. 05-06-16) Page 2
© California Land Title Association. All rights reserved.

The use of this Form is restricted to CLTA subscribers in good standing as of the date of use. All other uses are prohibited. Reprinted under license or express permission from the California Land Title Association. c. that result in no loss to You; or
d. that first occur after the Policy Date - this does not limit the coverage described in Covered Risk 7, 8.e., 25, 26, 27 or 28.

5. Failure to pay value for Your Title.

6. Lack of a right:
a. to any land outside the area specifically described and referred to in paragraph 3 of Schedule A; and b. in streets, alleys, or waterways that touch the Land.

This Exclusion does not limit the coverage described in Covered Risk 11 or 21.

7. The transfer of the Title to You is invalid as a preferential transfer or as a fraudulent transfer or conveyance under federal bankruptcy, state insolvency, or similar creditors’ rights laws.

8. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence.

9. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances.

LIMITATIONS ON COVERED RISKS
Your insurance for the following Covered Risks is limited on the Owner’s Coverage Statement as follows:
 For Covered Risk 16, 18, 19, and 21 Your Deductible Amount and Our Maximum Dollar Limit of Liability shown in Schedule A.

The deductible amounts and maximum dollar limits shown on Schedule A are as follows:

Your Deductible Amount
Our Maximum Dollar
Limit of Liability
Covered Risk 16: 1.00% of Policy Amount Shown in Schedule A or $2,500.00 (whichever is less)
$ 10,000.00
Covered Risk 18: 1.00% of Policy Amount Shown in Schedule A or $5,000.00 (whichever is less)
$ 25,000.00
Covered Risk 19: 1.00% of Policy Amount Shown in Schedule A or $5,000.00 (whichever is less)
$ 25,000.00
Covered Risk 21: 1.00% of Policy Amount Shown in Schedule A or $2,500.00 (whichever is less)
$ 5,000.00
2006 ALTA LOAN POLICY (06-17-06)

EXCLUSIONS FROM COVERAGE
The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, costs, attorneys' fees, or expenses that arise by reason of:

1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to
(i) the occupancy, use, or enjoyment of the Land;
(ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or
(iv) environmental protection;
or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify or limit the coverage provided under Covered Risk 5.
(b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 6.

2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8.

3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 11, 13 or 14); or
(e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Insured Mortgage.

4. Unenforceability of the lien of the Insured Mortgage because of the inability or failure of an Insured to comply with applicable doing-business laws of the state where the Land is situated.

5. Invalidity or unenforceability in whole or in part of the lien of the Insured Mortgage that arises out of the transaction evidenced by the Insured Mortgage and is based upon usury or any consumer credit protection or truth-in-lending law.

6. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors’ rights laws, that the transaction creating the lien of the Insured Mortgage, is
(a) a fraudulent conveyance or fraudulent transfer, or
(b) a preferential transfer for any reason not stated in Covered Risk 13(b) of this policy.

7. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the Insured Mortgage in the Public Records. This Exclusion does not modify or limit the coverage provided under Covered Risk 11(b).

The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage:

EXCEPTIONS FROM COVERAGE
{Except as provided in Schedule B - Part II,{ t{or T}his policy does not insure against loss or damage, and the Company will not pay costs, attorneys’ fees or expenses, that arise by reason of:

Page 1151 of 1828 ends

Attachment One – CA (Rev. 05-06-16) Page 3
© California Land Title Association. All rights reserved.

The use of this Form is restricted to CLTA subscribers in good standing as of the date of use. All other uses are prohibited. Reprinted under license or express permission from the California Land Title Association. {PART I
{The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage:

1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records.

2. Any facts, rights, interests, or claims that are not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land.

3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records.

4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records.

5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records.

6. Any lien or right to a lien for services, labor or material not shown by the Public Records.}

PART II
In addition to the matters set forth in Part I of this Schedule, the Title is subject to the following matters, and the Company insures against loss or damage sustained in the event that they are not subordinate to the lien of the Insured Mortgage:} 2006 ALTA OWNER’S POLICY (06-17-06)

EXCLUSIONS FROM COVERAGE
The following matters are expressly excluded from the coverage of this policy, and the Company will not pay loss or damage, costs, attorneys' fees, or expenses that arise by reason of:

1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to
(i) the occupancy, use, or enjoyment of the Land;
(ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or
(iv) environmental protection;
or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify or limit the coverage provided under Covered Risk 5.
(b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 6.

2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8.

3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 9 and 10); or
(e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Title.

4. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors’ rights laws, that the transaction vesting the Title as shown in Schedule A, is
(a) a fraudulent conveyance or fraudulent transfer; or
(b) a preferential transfer for any reason not stated in Covered Risk 9 of this policy.

5. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching between Date of Policy and the date of recording of the deed or other instrument of transfer in the Public Records that vests Title as shown in Schedule A.

The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage:

EXCEPTIONS FROM COVERAGE
This policy does not insure against loss or damage, and the Company will not pay costs, attorneys’ fees or expenses, that arise by reason of:
{The above policy form may be issued to afford either Standard Coverage or Extended Coverage. In addition to the above Exclusions from Coverage, the Exceptions from Coverage in a Standard Coverage policy will also include the following Exceptions from Coverage:

1. (a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records.

2. Any facts, rights, interests, or claims that are not shown in the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land.

3. Easements, liens or encumbrances, or claims thereof, not shown by the Public Records.

4. Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and that are not shown by the Public Records.

5. (a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water, whether or not the matters excepted under (a), (b), or (c) are shown by the Public Records.

6. Any lien or right to a lien for services, labor or material not shown by the Public Records. }

7. {Variable exceptions such as taxes, easements, CC&R’s, etc. shown here.}

Page 1152 of 1828 ends

Attachment One – CA (Rev. 05-06-16) Page 4
© California Land Title Association. All rights reserved.

The use of this Form is restricted to CLTA subscribers in good standing as of the date of use. All other uses are prohibited. Reprinted under license or express permission from the California Land Title Association.

ALTA EXPANDED COVERAGE RESIDENTIAL LOAN POLICY – ASSESSMENTS PRIORITY (04-02-15)

EXCLUSIONS FROM COVERAGE
The following matters are expressly excluded from the coverage of this policy and the Company will not pay loss or damage, costs, attorneys’ fees or expenses which arise by reason of:

1. (a) Any law, ordinance, permit, or governmental regulation (including those relating to building and zoning) restricting, regulating, prohibiting, or relating to
(i) the occupancy, use, or enjoyment of the Land;
(ii) the character, dimensions, or location of any improvement erected on the Land; (iii) the subdivision of land; or
(iv) environmental protection;
or the effect of any violation of these laws, ordinances, or governmental regulations. This Exclusion 1(a) does not modify or limit the coverage provided under Covered Risk 5, 6, 13(c), 13(d), 14 or 16. (b) Any governmental police power. This Exclusion 1(b) does not modify or limit the coverage provided under Covered Risk 5, 6, 13(c), 13(d), 14 or 16.

2. Rights of eminent domain. This Exclusion does not modify or limit the coverage provided under Covered Risk 7 or 8.

3. Defects, liens, encumbrances, adverse claims, or other matters (a) created, suffered, assumed, or agreed to by the Insured Claimant; (b) not Known to the Company, not recorded in the Public Records at Date of Policy, but Known to the Insured Claimant and not disclosed in writing to the Company by the Insured Claimant prior to the date the Insured Claimant became an Insured under this policy; (c) resulting in no loss or damage to the Insured Claimant; (d) attaching or created subsequent to Date of Policy (however, this does not modify or limit the coverage provided under Covered Risk 11, 16, 17, 18, 19, 20, 21, 22, 23, 24, 27 or 28); or
(e) resulting in loss or damage that would not have been sustained if the Insured Claimant had paid value for the Insured Mortgage.

4. Unenforceability of the lien of the Insured Mortgage because of the inability or failure of an Insured to comply with applicable doing-business laws of the state where the Land is situated.

5. Invalidity or unenforceability in whole or in part of the lien of the Insured Mortgage that arises out of the transaction evidenced by the Insured Mortgage and is based upon usury, or any consumer credit protection or truth-in-lending law. This Exclusion does not modify or limit the coverage provided in Covered Risk 26.

6. Any claim of invalidity, unenforceability or lack of priority of the lien of the Insured Mortgage as to Advances or modifications made after the Insured has Knowledge that the vestee shown in Schedule A is no longer the owner of the estate or interest covered by this policy. This Exclusion does not modify or limit the coverage provided in Covered Risk 11.

7. Any lien on the Title for real estate taxes or assessments imposed by governmental authority and created or attaching subsequent to Date of Policy. This Exclusion does not modify or limit the coverage provided in Covered Risk 11(b) or 25.

8. The failure of the residential structure, or any portion of it, to have been constructed before, on or after Date of Policy in accordance with applicable building codes. This Exclusion does not modify or limit the coverage provided in Covered Risk 5 or 6.

9. Any claim, by reason of the operation of federal bankruptcy, state insolvency, or similar creditors’ rights laws, that the transaction creating the lien of the Insured Mortgage, is
(a) a fraudulent conveyance or fraudulent transfer, or
(b) a preferential transfer for any reason not stated in Covered Risk 27(b) of this policy.

10. Contamination, explosion, fire, flooding, vibration, fracturing, earthquake, or subsidence.

11. Negligence by a person or an Entity exercising a right to extract or develop minerals, water, or any other substances.

Page 1153 of 1828 ends
Page 1154 of 1828 ends
Page 1155 of 1828 ends

Owner’s Declaration Printed: 6/27/2017 2:26 PM by AJ2
MISC0220 (DSI Rev. 10/17/17) Page 3
Escrow No. : 00811029-021-KH1

OWNER'S DECLARATION
Escrow No.: 00811029-021-KH1-DN1
Property Address: 1330 East Cypress Street
Covina, CA 91724
The undersigned hereby declares as follows:

1. (Fill in the applicable paragraph and strike the other) a. Declarant ("Owner") is the owner or lessee, as the case may be, of certain premises located at 1330 East Cypress Street, Covina, CA 91724, further described as follows: See Preliminary Report/Commitment No. for full legal description (the "Land").
b. Declarant is the ______________________________ of ____________________________________ ("Owner"), which is the owner or lessee, as the case may be, of certain premises located at 1330 East Cypress Street, Covina, CA 91724, further described as follows: See Preliminary Report/Commitment No. for full legal description (the "Land").

2. (Fill in the applicable paragraph and strike the other) a. During the period of six months immediately preceding the date of this declaration no work has been done, no surveys or architectural or engineering plans have been prepared, and no materials have been furnished in connection with the erection, equipment, repair, protection or removal of any building or other structure on the Land or in connection with the improvement of the Land in any manner whatsoever. b. During the period of six months immediately preceding the date of this declaration certain work has been done and materials furnished in connection with _________________________ upon the Land in the approximate total sum of $__________, but no work whatever remains to be done and no materials remain to be furnished to complete the construction in full compliance with the plans and specifications, nor are there any unpaid bills incurred for labor and materials used in making such improvements or repairs upon the Land, or for the services of architects, surveyors or engineers, except as follows:
___________________________________________. Owner, by the undersigned Declarant, agrees to and does hereby indemnify and hold harmless Ticor Title Company of California against any and all claims arising therefrom.

3. Owner has not previously conveyed the Land; is not a debtor in bankruptcy (and if a partnership, the general partner thereof is not a debtor in bankruptcy); and has not received notice of any pending court action affecting the title to the Land.

4. Except as shown in the above-referenced Preliminary Report/Commitment, there are no unpaid or unsatisfied mortgages, deeds of trust, Uniform Commercial Code financing statements, regular assessments, special assessments, periodic assessments or any assessment from any source, claims of lien, special assessments, or taxes that constitute a lien against the Land or that affect the Land but have not been recorded in the public records. There are no violations of the covenants, conditions and restrictions as shown in the above-referenced Preliminary Report/Commitment.

5. The Land is currently in use as _____________________; _______________________ occupy/occupies the Land; and the following are all of the leases or other occupancy rights affecting the Land:
___________________________________________________________________________________

6. There are no other persons or entities that assert an ownership interest in the Land, nor are there unrecorded easements, claims of easement, or boundary disputes that affect the Land.

7. There are no outstanding options to purchase or rights of first refusal affecting the Land.

8. Between the most recent Effective Date of the above-referenced Preliminary Report/Commitment and the date of recording of the Insured Instrument(s), Owner has not taken or allowed, and will not take or allow, any action or inaction to encumber or otherwise affect title to the Land.

This declaration is made with the intention that Ticor Title Company of California (the "Company") and its policy issuing agents will rely upon it in issuing their title insurance policies and endorsements. Owner, by the undersigned Declarant, agrees to indemnify the Company against loss or damage (including attorneys fees, expenses, and costs) incurred by the Company as a result of any untrue statement made herein.

I declare under penalty of perjury that the foregoing is true and correct and that this declaration was executed on ______________________________________________ at _________________________________.

Signature: ________________________________

Page 1156 of 1828 ends

Statement of Information Printed: 6/27/2017 2:26 PM by AJ2 MISC0008 (DSI Rev. 02/08/17) Page 4 Escrow No. : 00811029-021-KH1 Ticor Title Company of California Statement Of Information CONFIDENTIAL - TO BE USED ONLY IN CONNECTION WITH Transaction Number: 00811029-021-DN1 NOTE: This form is very important. It is needed to verify your identity and to eliminate judgments and liens against people with similar names.

THE STREET ADDRESS of the property in this transaction is: (If none, please leave blank) ADDRESS: CITY and STATE:

1. Improvements:  Single Residence  Multiple Residence  Commercial  Vacant Land

2. Occupied By:  Owner  Tenants 3. ANY CONSTRUCTION WITHIN THE LAST 6 MONTHS?  YES  NO

4. IF YES to No. 3, STATE NATURE WORK DONE:

PARTY 1 PARTY 2

First Middle Last First Middle Last

Former Last Name(s), if any Former Last Name(s), if any

Birthplace Birth Date Birthplace Birth Date

Social Security Number Driver’s License No. Social Security Number Driver’s License No.

I  am single  am married  have a registered domestic partner I  am single  am married  have a registered domestic partner Current Spouse or Registered Domestic Partner (Other Than Party 2): Current Spouse or Registered Domestic Partner (Other Than Party 1):

Name: Name:

Former spouse/domestic partner (if none – check this box ) Former spouse/domestic partner (if none – check this box  )  Deceased Date: Where:  Deceased Date: Where:
 Divorce/Dissolution Date: Where:  Divorce/Dissolution Date: Where:

Children from current and/or former marriages and/or domestic partnerships Children from current and/or former marriages and/or domestic partnerships Child Name: DOB Child Name: DOB
Child Name: DOB Child Name: DOB
Marriage or Domestic Partnership Between Parties 1 and 2 Are Parties 1 and 2:  Married? Date:  Registered Domestic Partners? Date:

Party 1 - Occupations For Last 10 Years (attach an additional page, if necessary)

Present Occupation Firm Name Address From To

Prior Occupation Firm Name Address From To
Party 1 - Residences For Last 10 Years (attach an additional page, if necessary)

Number And Street City, State, Zip Code From To

Number And Street City, State, Zip Code From To
Party 2 - Occupations For Last 10 Years (attach an additional page, if necessary)

Present Occupation Firm Name Address From To

Prior Occupation Firm Name Address From To
Party 2 - Residences For Last 10 Years (attach an additional page, if necessary)

Number And Street City, State, Zip Code From To

Number And Street City, State, Zip Code From To
Have any of the above parties owned or operated a business?  No  Yes If yes, please list name(s):

I have never been adjudged, bankrupt nor are there any unsatisfied judgments or other matters pending against me which might affect my title to this property except as follows:

The undersigned declare under penalty of perjury that the above information is true and correct (all parties must sign) Phone(s) # Phone(s) #
E-Mail: E-Mail:

Party 1 Signature Date Party 2 Signature Date

Page 1157 of 1828 ends

Agency Documents

Page 1158 of 1828 ends
Page 1159 of 1828 ends
Page 1160 of 1828 ends
Page 1161 of 1828 ends
Page 1162 of 1828 ends
Page 1163 of 1828 ends
Page 1164 of 1828 ends
Page 1165 of 1828 ends
Page 1166 of 1828 ends
Page 1167 of 1828 ends
Page 1168 of 1828 ends
Page 1169 of 1828 ends
Page 1170 of 1828 ends
Page 1171 of 1828 ends
Page 1172 of 1828 ends
Page 1173 of 1828 ends
Page 1174 of 1828 ends
Page 1175 of 1828 ends
Page 1176 of 1828 ends
Page 1177 of 1828 ends
Page 1178 of 1828 ends
Page 1179 of 1828 ends
Page 1180 of 1828 ends
Page 1181 of 1828 ends
Page 1182 of 1828 ends
Page 1183 of 1828 ends
Page 1184 of 1828 ends
Page 1185 of 1828 ends
Page 1186 of 1828 ends
Page 1187 of 1828 ends
Page 1188 of 1828 ends
Page 1189 of 1828 ends
Page 1190 of 1828 ends
Page 1191 of 1828 ends
Page 1192 of 1828 ends
Page 1193 of 1828 ends
Page 1194 of 1828 ends

L.A. COUNTY DPW HAZARDOUS MATERIALS SYSTEM REPORT: PWR050.001 DATE COMPILED: 06/25/99 IW INSPECTION JOB ORDER INSP~~: 1000310193 RUN DATE: 02/07/01 18:05:53 STORMWATER PC INSPECTION, NON- ASSC~~:

PAGE: 1
FILE ~~: 021302-030142 NAME:

ADD: 1330 E CYPRESS ST
COVINA, CA 91724 AREA: 6B SMD: 95
XSTREET: GLENDORA AVE THOMAS GUIDE: 0599-E4
CONTACT: MONTY JONES TEL: 626 967 9521
PROC: STORMWATER SAMPLE REQUIRED? N SAMPLE ~~:

INSP INFO: 2ND ROUND.

ASSGN T0: SAN DIMAS FIELD OFFICE SECT: FIELD INSPECTION UNIT RESULTS:

REMARKS:

INSPECTOR
DISP
~~;

Page 1195 of 1828 ends

~~~OE t
G,y
~ aue~c woiucs
~Q ~ ,~ ~o
S°tile t~~
COUNTY OF LOS ANGF,LES • DEPARTMEN7~ OF PUBLIC WORKS Site/File ~~~ 3 ' U2 ~3 ~ ~ ~ °t`

ENVIRONMENTAL PROGRAMS DIVISION G
Storm Water Facility Inspection/Site Visit Report Form Inspection Work Order (I) `~~'~' ~~` ~-!~ ~.~ ~~J D
❑ Firs[ Inspection outine Inspection o Response to Complaint ❑Facility has closed or new Facility Information (see attached) Facility Name: ~ ~~~,~Q~ Site Address: 3 ~j t} G • C~ ~ j/`.~•~-- g Contact Name: r ~ ~ J ~p~yn done: ~~1-~~ `~ (~ ~~S `~'~ Business Type/Activity: r~,(,~C c~~N~~ 7 a~~ i. ~~„
Is [he facility within the County unincorporated area ? ❑Yes ❑ City: ~~ ` ~~ Is th i ty covered under any other permits`' heck all that apply) A uality azmat business plan
ire Dept. (Storage) ❑Hazardous waste generator
Area (R/C) Code: ~~
SIC: ~~
❑None ❑Industrial Waste
Underground Storage Tanks ❑Aboveground storage tanks
❑ Other:

Is the facility covered under a storm water permit? woes not need coverage ❑ No, but may need to (Refer to Regional Board) ❑General (filed NOI) ❑Individual NPDES
Does the facility have a SWPPP? ❑Yes o

ACTIVITIES ASSESSMENT CHECKLIST
ACTIVITIES -Check each activity present at the site and evaluate its potential for APPLICABLE EFFECTIVENESS pollutant discharge (PPD): 1 =low potential, 2 = medium potential, 3 =high ACTIVITY RATING* potential Yes No PPD
-1 Circled BMPs require your immediate attention -see back of this report.

A. MINIMUM BMPs - APPLICABLE TO L FACILITIES [ ✓ ] [ ] [ ] O D O O D BMPs employed: ~ ~ ~ ~ ~j
B. VEHICLE AND EQU PMENT FU L[NG [ ] L C l OO OO OO 4O D BMPs employed:

C. VEHICLE AND EQUIPMENT WASHINGlSTEAM CLEANING [ ] [ [ ] O O O O O BMPs employed:

D. VEHICLE AND EQUIPMENT MAINTENANCE AND REPAIR [ ] [ [ ] O O O O D BMPs employed:

E. OUTDOOR LOADING/iJNLOADING OF MATERIALS [ [ ] [ ~ l OO OO OO i D BMPs employed: ~j
F. OUTDOOR PROCESS EQUI MENT OPERATIONS AND MAINTENANCE [ ] [ ] ( ] O D O O O BMPs employed:

G. OUTDOOR STORAGE OF RAW M TERIALS/PRODUCTS/CONTAINERS [ [ ] [ (] OO D OO 4O ~ BMPs employed: ( 02 g
H. WASTE HANDLING ND I~ISPOSAL
~ ~j ~
[ [ I C ~~ OO D OO ~ D
BMPs employed: ~
I. CONTAMINATED OR ERODIBLE URFACE AREAS [ ] [ ' [ ] O D O O D BMPs employed:

J. BUILDING AND GROUNDS MAINTENANCE [ • [ ] [ r ] OO D OO ~ D BMPs employed:

K. ROOFTOP EQUIPMENT [ L ; " l r) OO ~ OO ~ D
BMPs employed:

I
L. OUTDOOR DRAINAGE FROM INDOOR AREAS [ ] ~[[ ] OO D OO 4O D BMPs employed':

M. OTHER (describe): l ~ ~ C ~ OO ~ OO OO ~
*~ No BMPs used and stormwater pollution likely ~ Some BMPs used but not effective ~ Some BMPs used and moderately effective ~ Source control BMPs used and very effective/structural BMPs needed ~ All necessary BMPs used and very effective This report is not a citation. It is furnished to the. facility representative to assist in designing and eva ing Best Management Practices to prevent the runoff of pollutants to the storm drainage system A reinspection of your facility (o is required) ~s not required) to review correction of deficiencies noted above. Please call ( ) _ by between 8:00 a.m. to 9:30 a.m. to arrange for a reinspection.

Facility Representative Signature: ~ ,---- Date: 3 D
Print name of Facility Representative: / — --Z~ Inspector: ~ ~ ~ ~ ~ ~~~ 40-0056 DPW 10/99

OFFICE COPY

Page 1196 of 1828 ends

L.A. COUNTY DPW HAZARDOUS MATERIALS SYSTEM REPORT: PWRO50.001 DATE COMPILED: 06/25/99 IW INSPECTION JOB ORDER INSP~~: I000268274 RUN DATE: 09/22/99 09:09:27 STORMWATER PC INSPECTION, NON- ASSC~~:

PAGE: 1
FK.Y/~/ ~L M~
FILE ~~: 021302-030142 NAME: -E~ A3VD G--SOWER SYSTEM
ADD: 1330 E CYPRESS ST
COVINA, CA 91724 AREA: 6B SMD: 95
XSTREET: ~LEi✓~~E'..gJ ~JVE. THOMAS GUIDE: -0000-00 J ~5' j' --- L=; CONTACT: JOAN RAUSEO TEL: 626 967 9521
f r ~on~T~ tJ cnl~~
PROC: STORMWATER SAMPLE REQUIRED? N SAMPLE ~~:

INSP INFO: CONDUCT STORMWATER SURVEY
ASSGN T0: SAN DIMAS FIELD OFFICE SECT: FIELD INSPECTION UNIT RESULTS: -L
i ~'
,, ~ /~ ~ v
~ `,
_ ~ i
C,
REMARKS: ~1~iv~ i f"'`~ -r G"` t ~ ~c c '~G .-i F.~
~_ % i /
INSPECTOR: ~~//~ -~ ~ ,_ -`~~, L ,cl,-G~L INSPECTION DATE: i`~ f ~ GG ;'
DISP: ~ ~'~~~
~ D `I'

Page 1197 of 1828 ends

oy~~ELES ~pGy`
COUNTY OF LOS ANGELES ~ DEPARTMENT OF PUBLIC WORKS Site/File~,E~G~ I.v~~ /~ ~ PUBLIC WORKS e ENVIRONMENTAL PROGRAMS DIVISION
~°~~ a~° Storm Water Facility Inspection/Site Visit Report Form Inspection Work Order (I) ~ cf~1 f sB•vlce rn~
First Ins ection ❑Routine Ins ection ❑Res onse to Com laint ❑ Facili has closed or new Facilit Information see attached Facility Name: ~c~,~~~ ~;.,Lm~~ Site Address: ~33c~ E• Cy~RE~ lea (R/C) Code:

Contact Name: /rjon?)/ ~~~ Phone:~2, ~ 9~ S~a/Business Type/Activity: ~"L.~C7'~C~~C. i'h /~6.

Is the facility within the County unincorporated area ? ❑Yes ~IIo City: ~ a ~~ ~ ~' sic:, ~3'~ 9
Is the facility covered under any other permits? (Check all that apply) ❑None ❑Industrial Waste Air Quality ~Hazmat business plan ❑Underground Storage Tanks ❑Aboveground storage tanks ❑ Fire Dept. (Storage) ❑Hazardous waste generator ❑Other:

Is the facility covered under a storm water permit? Does not need coverage ❑ No, but may need to (Refer to Regional Board) General (filed NOI) ❑Individual NPDES
Does the facility have a SWPPP? ❑Yes. ~No

ACTIVITIES ASSESSMENT CHECKLIST
ACTIVITIES -Check each activity present at the site and evaluate its potential for APPLICABLE EFFECTIVENESS pollutant discharge (PPD): 1 =low potential, 2 =medium potential, 3 =high ACTIVITY RATING* potential Yes No PPD
—~ Circled BMPs require your immediate attention -see back of this report.

A. MINIMUM BMPs - APPLICABLE TQ
`~
ALL CILI~ES L ✓~ L l C ~ I OO OO OO 4O
BMPs employed: f ,Z 3
~ `~
~
B. VEHICLE AND EQUIPMENT FUELING [ ) [ ) L I OO OO OO 4O 5O BMPs employed:

C. VEHICLE AND EQUIPMENT WASHING/STEAM CLEANING [ ] [ C l O O O O O BMPs employed:

D. VEHICLE AND EQUIPMENT MAINTENANCE AND REPAIR [ ] [ ] [ ] O O O O O BMPs employed:

E. OUTDOOR LOADING/UNLOADING OF MATERIALS [ ] [ ] C l O O O O O BMPs employed:

F. OUTDOOR PROCESS EQUIPMENT OPERATIONS AND MAINTENANCE [ [ ] [ 1 ] O O O O BMPs employed:,
G. OUTDOOR STO~GE OF RAW MATERIALS/PRODUCTS/CONTAINERS [ ] [ ] C ~~ OO OO OO 4O BMPs employed:

H. WASTE HANDLING AND DISPOSAL [ ] C ] C I ] OO OO OO 4O BMPs employed: ~ ~ 2 ~ ~ ~ ~ ~
I. CONTAMINATED OR ERODIBLE SU ACE AR AS [ ] [ • ~ C 1 I O O O O BMPs employed: p~
J. BUILDING AND GR~UNDS MAINTENANCE [ ] [ ] C ,) OO OO OO 4O BMPs employed:

K. ROOFTOP EQUIPMENT C ) I I I ~ OO OO OO 4O
BMPs employed:

L. OUTDOOR DRAINAGE FROM INDOOR AREAS [ 1 C I ~ O O O O O BMPs employed:

M. OTHER (describe): ~ ~ ~ ) ~ ~ ~ ~ ~ 0 ~
*0 No BMPs used and stormwater pollution likely ~ Some BMPs used but not effective ~ Some BMPs used and moderately effective Source control BMPs used and very effectivelstructural BMPs needed ~ All necessary BMPs u~ and very effective This repoR is not a citation. It is furnished to the facility representative to assist in designing and eva ling Best Management Practices to prevent the runoff of pollutants to the storm drainage system. A reinspection of your facility (o is required)( ~s not required) to review correction of deficiencies noted above. Please call ( ) by between 8:00 a.m. to 9:30 a.m. tc Facility Representative Signature: /r I Date: _
Print name of Facility Representative: .~py1,T1~ ~. J-oNGs Inspector:
40-0056 DPW 10/99
OFFICE CC3P1'

Page 1198 of 1828 ends

CITY OF COVINA

VIA ELECTRONIC MAIL
May 27,2021
Jennifer Woods
3621 S. Harbor Blvd., Ste. 115
Santa Ana, CA 92705
[email protected]
Re: Public Records Act Request PRR 21-146
Dear Ms. Woods:

On May 25, 2021, the City of Covina ("City") received your request for public records. In accordance with Government Code Sections 6253(c) and 6255(b), this letter serves as the City's written response to your request. Your request is as follows:
• Building permit records available for 1330 Cypress St.

The City's response is as follows:

Attached are the documents determined to be responsive to your request as stated above.

Should you have any questions or require additional information, please contact our office at 626-384-5430 or [email protected].

Respectfully,
Fabian Velez
Records Technician

Page 1199 of 1828 ends
Page 1200 ends

1828

Page 1201 of 1828 ends
Page 1202 of 1828 ends
Page 1203 of 1828 ends
Page 1204 of 1828 ends
Page 1205 of 1828 ends
Page 1206 of 1828 ends
Page 1207 of 1828 ends
Page 1208 of 1828 ends
Page 1209 of 1828 ends
Page 1210 of 1828 ends
Page 1211 of 1828 ends
Page 1212 of 1828 ends
Page 1213 of 1828 ends
Page 1214 of 1828 ends
Page 1215 of 1828 ends
Page 1216 of 1828 ends
Page 1217 of 1828 ends
Page 1218 of 1828 ends
Page 1219 of 1828 ends
Page 1220 of 1828 ends
Page 1221 of 1828 ends
Page 1222 of 1828 ends
Page 1223 of 1828 ends
Page 1224 of 1828 ends
Page 1225 of 1828 ends
Page 1226 of 1828 ends
Page 1227 of 1828 ends
Page 1228 of 1828 ends
Page 1229 of 1828 ends
Page 1230 of 1828 ends
Page 1231 of 1828 ends
Page 1232 of 1828 ends
Page 1233 of 1828 ends
Page 1234 of 1828 ends
Page 1235 of 1828 ends
Page 1236 of 1828 ends
Page 1237 of 1828 ends
Page 1238 of 1828 ends
Page 1239 of 1828 ends
Page 1240 of 1828 ends
Page 1241 of 1828 ends
Page 1242 of 1828 ends
Page 1243 of 1828 ends

Situs Address 1330 E Cypress St
Permit # Permit Type Plumbing B00-007-124
Permit Type
1330 E Cypress St
Installation of a 3" Backflow Prevention Device on Water Supply.

Plumbing Permit No B00-007-124 System Status Final
Situs Address Agency Status Finaled
Situs City Covina, CA 91724
Parcel No 8427-001-006
Project No
Tract No
TRA
Use
No of Units
No of Stories
Description
Geo Area
Case No
Block No
Zoning
Occup Grp
Square Feet
02645
3100 - Light Manufacturing, 1 Story CVM1
0 0 54,672
Application Date
Issue Date
Expire Date
Final Date
Census Occupancy
Valuation $0.00
10/22/2012
09/27/2012
09/27/2012
04/20/2013
Lot No
# Bathrms
# Bedrms 0

0.00 Constr. Type
Sprinklered No
Owner
940 Winter St
Waltham, MA 02451
PHONE NO.

FAX NO.

Lumen Technologies Inc
Applicant

NO ACTIVE APPLICANTS
Tenant

NO ACTIVE TENANTS
Service Provider
Perusse, Dan
708 S Corrida Dr 468055
C36
01/31/2013
Covina, CA 91724
Perusse Plumbing Corp.

License Information
State License No.

Type:

Expires
City License No. 035220 Expires 12/31/2012
Service Provider Type
Contact
Title
Company
Contractor
Address
Mailing Address
708 S Corrida Dr
Covina, CA 91724
(626) 915-3964
Email Address
Phone
Fax
Status
Active
Active
Yes

Page 1244 of 1828 ends