Note that portions of Planning Areas 3A and 4A within the Project site have been developed.
Planning Areas 2, 3, 4A, 5C, 6, 10, and portions of 7, 8, and 9 are anticipated to be developed as part of the first phase with an anticipated Opening Year of 2024. Project Buildout and of Phase 2 is anticipated in Year 2027. Project Planning Areas and Phases are illustrated at Exhibit 1-B.
The on-site Project-related noise sources are expected to include: loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, truck movements and park activities. This noise analysis is intended to describe noise level impacts associated with the expected typical operational activities at the Project site. 5926
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
5 EXHIBIT 1-B: LAND USE PLAN
5927
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
6 1.2 RECOMMENDED CONDITIONS OF APPROVAL
As substantiated in this analysis, all Project-source noise and vibration impacts would be lessthan-significant. . The following measures would further reduce Project noise impacts. To ensure that Project noise impacts remain at levels that would be less-than-significant, it is recommended that the following noise abatement measures be incorporated as Project Conditions of Approval
1.2.1: Prior to Grading Permit issuance, the Applicant shall demonstrate that the project complies with the following:
• All construction equipment, fixed or mobile, shall be equipped with properly operating and maintained mufflers, to the satisfaction of the Noise Control Officer; • During construction, stationary construction equipment shall be placed such that emitted noise is directed away from sensitive noise receiversto the satisfaction of the City Planner; and
• During construction and to the satisfaction of the City Planner, stockpiling and vehicle staging areas shall be located as far as practical from noise sensitive receptors during construction activities.
1.2.2: Operating or causing the operation of any tools or equipment used in construction, drilling, repair, alteration, or demolition work between the hours of 10:00 p.m. and 7:00 a.m. during is prohibited. The City Planner may approve additional hours when it can be found that such additional hours will not generate additional disturbance, or that mitigation measures will ensure compatibility with nearby residential areas.
1.2.3: Prior to the construction of residential development along Riverside Drive, Haven Avenue, Mill Creek Avenue, Edison Avenue, and Milliken Avenue, an acoustical noise analysis should be prepared prior to the submittal of final tentative tract maps to ensure that exterior and interior noise levels are met. The acoustical analysis shall demonstrate that the buildings have been designed to limit interior noise levels to 45 dBA CNEL and exterior noise (backyards and habitable balconies and patios) to less than 65 dBA CNEL. Individual developments shall, to the extent feasible, implement site‐planning techniques.
1.2.4: Prior to final development plan approval, on a project‐by‐project basis and to the discretion of the Ontario Planning Department, subsequent noise studies shall be prepared, which demonstrates the site placement of stationary noise sources would not exceed criteria established in the City of Ontario Municipal Code. The analysis shall verify that loading dock facilities, rooftop equipment, trash compactors and other stationary noise sources are adequately shielded and/or located at an adequate distance from residential areas in order to comply with the City’s noise standards.
1.2.5: Prior to Building Permit issuance and to the satisfaction of the Ontario Planning Department, the Project Applicants, on a project‐by‐project basis, shall demonstrate compliance with the following with respect to mechanical equipment:
• Mechanical equipment shall include specifications of quiet equipment; 5928
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
7 • Mechanical equipment shall be properly selected and installed, and shall include sound attenuation packages;
• To the extent possible, mechanical equipment shall be oriented away from the nearest noise sensitive receptors; and
• The need for sound attenuation measures, and design of, such measures shall be determined as part of the final engineering design on a project‐by‐project basis.
1.2.6: Where a commercial zone abuts a residential zone or residential use, all deliveries of goods and supplies; trash pick‐up, including the use of parking lot trash sweepers; and the operation of machinery or mechanical equipment which emits noise levels in excess of 65 dBA, as measured from the closest property line to the equipment, shall only be allowed between the hours of 7:00 a.m. and 10:00 p.m., unless otherwise specified in an approved conditional use permit or other discretionary approval.
1.2.7: Prior to final development plan approval, on a project‐by‐project basis, a subsequent noise analysis shall be prepared, to the satisfaction of the Ontario Planning Department, which demonstrates that all feasible sound attenuation has been incorporated into the parking areas (i.e., landscaping and brushed driving surfaces), such that noise from parking area has been minimized to the greatest extent practicable. 5929
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
8 This page intentionally left blank
5930
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
9 2 FUNDAMENTALS
Noise is simply defined as "unwanted sound." Sound becomes unwanted when it interferes with normal activities, when it causes actual physical harm or when it has adverse effects on health.
Noise is measured on a logarithmic scale of sound pressure level known as a decibel (dB). Aweighted decibels (dBA) approximate the subjective response of the human ear to broad frequency noise source by discriminating against very low and very high frequencies of the audible spectrum. They are adjusted to reflect only those frequencies which are audible to the human ear. Exhibit 2-A presents a summary of the typical noise levels and their subjective loudness and effects that are described in more detail below.
EXHIBIT 2-A: TYPICAL NOISE LEVELS
Source: Environmental Protection Agency Office of Noise Abatement and Control, Information on Levels of Environmental Noise Requisite to Protect Public Health and Welfare with an Adequate Margin of Safety (EPA/ONAC 550/9-74-004) March 1974.
2.1 RANGE OF NOISE
Since the range of intensities that the human ear can detect is so large, the scale frequently used to measure intensity is a scale based on multiples of 10, the logarithmic scale. The scale for measuring intensity is the decibel scale. Each interval of 10 decibels indicates a sound energy ten times greater than before, which is perceived by the human ear as being roughly twice as loud. (2) The most common sounds vary between 40 dBA (very quiet) to 100 dBA (very loud). Normal conversation at three feet is roughly at 60 dBA, while loud jet engine noises equate to 110 dBA 5931
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
10 at approximately 1,000 feet, which can cause serious discomfort. (3) Another important aspect of noise is the duration of the sound and the way it is described and distributed in time.
2.2 NOISE DESCRIPTORS
Environmental noise descriptors are generally based on averages, rather than instantaneous, noise levels. The most used metric is the equivalent level (Leq). Equivalent sound levels are not measured directly but are calculated from sound pressure levels typically measured in Aweighted decibels (dBA). The equivalent sound level (Leq) represents a steady state sound level containing the same total energy as a time varying signal over a given sample period and is commonly used to describe the “average” noise levels within the environment.
Peak hour or average noise levels, while useful, do not completely describe a given noise environment. Noise levels lower than peak hour may be disturbing if they occur during times when quiet is most desirable, namely evening and nighttime (sleeping) hours. To account for this, the Community Noise Equivalent Level (CNEL), representing a composite 24-hour noise level is utilized. The CNEL is the weighted average of the intensity of a sound, with corrections for time of day, and averaged over 24 hours. The time-of-day corrections require the addition of 5 decibels to dBA Leq sound levels in the evening from 7:00 p.m. to 10:00 p.m., and the addition of 10 decibels to dBA Leq sound levels at night between 10:00 p.m. and 7:00 a.m. These additions are made to account for the noise sensitive time periods during the evening and night hours when noise can become more intrusive. CNEL does not represent the actual sound level heard at any time, but rather represents the total sound exposure. The City of Ontario relies on the 24- hour CNEL level to assess land use compatibility with transportation related noise sources.
2.3 SOUND PROPAGATION
When sound propagates over a distance, it changes in level and frequency content. The way noise reduces with distance depends on the following factors.
2.3.1 GEOMETRIC SPREADING
Sound from a localized source (i.e., a stationary point source) propagates uniformly outward in a spherical pattern. The sound level attenuates (or decreases) at a rate of 6 dB for each doubling of distance from a point source. Highways consist of several localized noise sources on a defined path and hence can be treated as a line source, which approximates the effect of several point sources. Noise from a line source propagates outward in a cylindrical pattern, often referred to as cylindrical spreading. Sound levels attenuate at a rate of 3 dB for each doubling of distance from a line source. (2)
2.3.2 GROUND ABSORPTION
The propagation path of noise from a highway to a receiver is usually very close to the ground.
Noise attenuation from ground absorption and reflective wave canceling adds to the attenuation associated with geometric spreading. Traditionally, the excess attenuation has also been expressed in terms of attenuation per doubling of distance. This approximation is usually 5932
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
11 sufficiently accurate for distances of less than 200 ft. For acoustically hard sites (i.e., sites with a reflective surface between the source and the receiver, such as a parking lot or body of water), no excess ground attenuation is assumed. For acoustically absorptive or soft sites (i.e., those sites with an absorptive ground surface between the source and the receiver such as soft dirt, grass, or scattered bushes and trees), an excess ground attenuation value of 1.5 dB per doubling of distance is normally assumed. When added to the cylindrical spreading, the excess ground attenuation results in an overall drop-off rate of 4.5 dB per doubling of distance from a line source. (4)
2.3.3 ATMOSPHERIC EFFECTS
Receivers located downwind from a source can be exposed to increased noise levels relative to calm conditions, whereas locations upwind can have lowered noise levels. Sound levels can be increased at large distances (e.g., more than 500 feet) due to atmospheric temperature inversion (i.e., increasing temperature with elevation). Other factors such as air temperature, humidity, and turbulence can also have significant effects. (2)
2.3.4 SHIELDING
A large object or barrier in the path between a noise source and a receiver can substantially attenuate noise levels at the receiver. The amount of attenuation provided by shielding depends on the size of the object and the frequency content of the noise source. Shielding by trees and other such vegetation typically only has an “out of sight, out of mind” effect. That is, the perception of noise impact tends to decrease when vegetation blocks the line-of-sight to nearby residents. However, for vegetation to provide a substantial, or even noticeable, noise reduction, the vegetation area must be at least 15 feet in height, 100 feet wide and dense enough to completely obstruct the line-of-sight between the source and the receiver. This size of vegetation may provide up to 5 dBA of noise reduction. The Federal Highway Administration (FHWA) does not consider the planting of vegetation to be a noise abatement measure. (5)
2.4 NOISE CONTROL
Noise control is the process of obtaining an acceptable noise environment for an observation point or receiver by controlling the noise source, transmission path, receiver, or all three. This concept is known as the source-path-receiver concept. In general, noise control measures can be applied to these three elements.
2.5 NOISE BARRIER ATTENUATION
Effective noise barriers can reduce noise levels by 10 to 15 dBA, cutting the loudness of traffic noise in half. A noise barrier is most effective when placed close to the noise source or receiver.
Noise barriers, however, do have limitations. For a noise barrier to work, it must block the lineof-sight path of sound from the noise source. 5933
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
12 2.6 LAND USE COMPATIBILITY WITH NOISE
Some land uses are more tolerant of noise than others. For example, schools, hospitals, churches, and residences are more sensitive to noise intrusion than are commercial or industrial developments and related activities. As ambient noise levels affect the perceived amenity or livability of a development, so too can the mismanagement of noise impacts impair the economic health and growth potential of a community by reducing the area’s desirability as a place to live, shop and work. For this reason, land use compatibility with the noise environment is an important consideration in the planning and design process. The FHWA encourages State and Local government to regulate land development in such a way that noise-sensitive land uses are either prohibited from being located adjacent to a highway, or that the developments are planned, designed, and constructed in such a way that noise impacts are minimized. (6)
2.7 COMMUNITY RESPONSE TO NOISE
Approximately sixteen percent of the population has a very low tolerance for noise and will object to any noise not of their making. Consequently, even in the quietest environment, some complaints may occur. Twenty to thirty percent of the population will not complain even in very severe noise environments. (7 pp. 8-6) Thus, a variety of reactions can be expected from people exposed to any given noise environment.
Surveys have shown that community response to noise varies from no reaction to vigorous action for newly introduced noises averaging from 10 dB below existing to 25 dB above existing. (8) According to research originally published in the Noise Effects Handbook (7), the percentage of high annoyance ranges from approximately 0 percent at 45 dB or less, 10 percent are highly annoyed around 60 dB, and increases rapidly to approximately 70 percent being highly annoyed at approximately 85 dB or greater. Despite this variability in behavior on an individual level, the population can be expected to exhibit the following responses to changes in noise levels as shown on Exhibit 2-B. A change of 3 dBA is considered barely perceptible, and changes of 5 dBA are considered readily perceptible. (4)
EXHIBIT 2-B: NOISE LEVEL INCREASE PERCEPTION
0 1 2 3 4 5 6 7 8 9 10
Just Perceptible
Barely Perceptible
Readily Perceptible
Twice as Loud
Noise Level Increase (dBA)
5934
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
13 2.8 VIBRATION
Per the Federal Transit Administration (FTA) Transit Noise Impact and Vibration Impact Assessment Manual (8), vibration is the periodic oscillation of a medium or object. The rumbling sound caused by the vibration of room surfaces is called structure-borne noise. Sources of ground-borne vibrations include natural phenomena (e.g., earthquakes, volcanic eruptions, sea waves, landslides) or human-made causes (e.g., explosions, machinery, traffic, trains, construction equipment). Vibration sources may be continuous, such as factory machinery, or transient, such as explosions. As is the case with airborne sound, ground-borne vibrations may be described by amplitude and frequency.
There are several different methods that are used to quantify vibration. The peak particle velocity (PPV) is defined as the maximum instantaneous peak of the vibration signal. The PPV is most frequently used to describe vibration impacts to buildings but is not always suitable for evaluating human response (annoyance) because it takes some time for the human body to respond to vibration signals. Instead, the human body responds to average vibration amplitude often described as the root mean square (RMS). The RMS amplitude is defined as the average of the squared amplitude of the signal and is most frequently used to describe the effect of vibration on the human body. Decibel notation (VdB) is commonly used to measure RMS. Decibel notation (VdB) serves to reduce the range of numbers used to describe human response to vibration.
Typically, ground-borne vibration generated by man-made activities attenuates rapidly with distance from the source of the vibration. Sensitive receivers for vibration include structures (especially older masonry structures), people (especially residents, the elderly, and sick), and vibration-sensitive equipment and/or activities.
The background vibration-velocity level in residential areas is generally 50 VdB. Ground-borne vibration is normally perceptible to humans at approximately 65 VdB. For most people, a vibration-velocity level of 75 VdB is the approximate dividing line between barely perceptible and distinctly perceptible levels. Typical outdoor sources of perceptible ground-borne vibration are construction equipment, steel-wheeled trains, and traffic on rough roads. If a roadway is smooth, the ground-borne vibration is rarely perceptible. The range of interest is from approximately 50 VdB, which is the typical background vibration-velocity level, to 100 VdB, which is the general threshold where minor damage can occur in fragile buildings. Exhibit 2-C illustrates common vibration sources and the human and structural response to ground-borne vibration. 5935
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
14 EXHIBIT 2-C: TYPICAL LEVELS OF GROUND-BORNE VIBRATION Source: Federal Transit Administration (FTA) Transit Noise and Vibration Impact Assessment Manual. 5936
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
15 3 REGULATORY SETTING
The federal government, the State of California, various county governments, and most municipalities in the state have established standards and ordinances to control noise. In most areas, automobile and truck traffic is the major source of environmental noise. Traffic activity generally produces an average sound level that remains constant with time. Air and rail traffic, and commercial and industrial activities are also major sources of noise in some areas. Federal, state, and local agencies regulate different aspects of environmental noise. Federal and state agencies generally set noise standards for mobile sources such as aircraft and motor vehicles, while regulation of stationary sources is left to local agencies.
3.1 STATE OF CALIFORNIA NOISE REQUIREMENTS
The State of California regulates freeway noise, sets standards for sound transmission, provides occupational noise control criteria, identifies noise standards, and provides guidance for local land use compatibility. State law requires that each county and city adopt a General Plan that includes a Noise Element which is to be prepared per guidelines adopted by the Governor’s Office of Planning and Research (OPR). (9) The purpose of the Noise Element is to limit the exposure of the community to excessive noise levels. In addition, the California Environmental Quality Act (CEQA) requires that all known environmental effects of a project be analyzed, including environmental noise impacts.
3.2 CITY OF ONTARIO GENERAL PLAN NOISE ELEMENT
The City of Ontario General Plan (Policy Plan) identifies several policies to minimize the impacts of excessive noise levels throughout the community. Policy Plan Section S4, Noise Hazards, establishes a goal of maintaining an environment where noise does not adversely affect the public’s health, safety, and welfare. (10) To satisfy this goal, the Policy Plan identifies seven policies related to: noise mitigation; coordination with transportation authorities; noise mitigation; truck traffic; roadway design; airport noise compatibility and rail noise mitigation.
The noise criteria identified on Table 5-13-3 of The Ontario Plan 2050 Final Supplemental Environmental Impact Report (FSEIR) (11) provide guidelines to evaluate land use compatibility within various noise environments. Table 5-13-3 is reproduced here as Exhibit 3-A Ontario Noise Level Exposure and Land Use Compatibility Guidelines.
5937
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
16 EXHIBIT 3-A: ONTARIO NOISE LEVEL EXPOSURE AND LAND USE COMPATIBILITY GUIDELINES Source: The Ontario Plan 2050 Draft SEIR (Table 5.13-3).
3.3 OPERATIONAL NOISE STANDARDS
To analyze noise impacts originating from a designated fixed location or private property such as the Rich-Haven Specific Plan-2022 Amendment, stationary-source (operational) noise levels are evaluated against standards established under a City’s Municipal Code. The City of Ontario requires that noise from new stationary sources in the City comply with the City’s Noise Ordinance, which limits the acceptable noise at the property line of the impacted property, to reduce nuisances to sensitive land uses. Compliance with the City’s Noise Ordinance would result in noise levels that are acceptable to the City and would result in less than significant noise impacts from stationary sources. The City of Ontario Municipal Code, Title 5, Chapter 29 noise standards are included in Appendix 3.1.
Section 5-29.04(a) identifies the allowable daytime and nighttime ambient exterior noise standards for each land use type. For Manufacturing and Industrial land uses (Noise Zone V), such as the Project, ambient exterior noise levels may not exceed 70 dBA Leq. For residential land uses (Noise Zone I), ambient exterior noise levels may not exceed 65 dBA Leq during the daytime hours (7:00 a.m. to 10:00 p.m.) and may not exceed 45 dBA Leq during the nighttime hours (10:00 5938
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
17 p.m. to 7:00 a.m.) (12). The lower noise level standard shall apply on the boundary between two (2) different noise zones. If the ambient noise level exceeds the resulting standard, the ambient noise level shall be the standard. The maximum acceptable Project-related operational noise levels received at off-site land uses in the City of Ontario are identified on Table 3-1.
TABLE 3-1: OPERATIONAL NOISE STANDARDS
Noise Zone Land Use
Exterior Noise Levels (dBA Leq)2
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
I Single-Family Residential 65 45
II Multi-Family Residential 65 50
III Commercial 65 60
IV Residential Mixed-Use 70 70
V Manufacturing and Industrial 70 70
1 Source: Section 5-29.04 of the City of Ontario Municipal Code (Appendix 3.1). 2 Leq represents a steady state sound level containing the same total energy as a time varying signal over a given period.
3.4 CONSTRUCTION NOISE STANDARDS
The City of Ontario has set restrictions to control noise impacts associated with construction.
Section 5-29.09 of the Municipal Code states: No person, while engaged in construction, remodeling, digging, grading, demolition or any other related building activity, shall operate any tool, equipment or machine in a manner that produces loud noise that disturbs a person of normal sensitivity who works or resides in the vicinity, or a Police or Code Enforcement Officer, on any weekday except between the hours of 7:00 a.m. and 6:00 p.m. or on Saturday or Sunday between the hours of 9:00 a.m. and 6:00 p.m. (12) While the City establishes limits to the hours during which construction activity may take place, it does not identify specific noise level limits for construction noise levels at potentially affected receiver locations for CEQA analysis purposes.
Construction noise would be considered significant if construction activities occurring outside of the hours specified (7:00 AM and 6:00 PM weekdays and 9:00 AM to 6:00 PM weekends, excluding federal holidays) or if construction activities substantially elevate the ambient noise environment at noise-sensitive uses for a substantial period. It is assumed that the Modified Project construction activities would comply with the City’s hour of activity restrictions, thereby precluding construction activities during noise-sensitive time periods. However, neither the City of Ontario General Plan Noise Element or Municipal Codes establish numeric maximum acceptable construction source noise levels at potentially affected receivers, which would allow for a quantified determination of what CEQA constitutes a substantial temporary or permanent increase in ambient noise levels. Therefore, a numerical construction threshold based on Federal Transit Administration (FTA) Transit Noise and Vibration Impact Assessment Manual is used for analysis of daytime construction impacts. The FTA considers a daytime exterior construction noise level of 80 dBA Leq as a reasonable threshold for noise sensitive land use. (8 p. 179) 5939
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
18 3.5 VIBRATION STANDARDS
Construction activity can result in varying degrees of ground-borne vibration, depending on the equipment and methods used, distance to the affected structures and soil type. Construction vibration is generally associated with pile driving and rock blasting. Other construction equipment such as air compressors, light trucks, hydraulic loaders, etc., generates little or no ground vibration. (8) To analyze vibration impacts originating from the operation and construction of Rich-Haven Specific Plan-2022 Amendment, vibration-generating activities are appropriately evaluated against standards established under a City’s Municipal Code, if such standards exist. However, the City of Ontario does not identify specific vibration level limits.
Therefore, for analysis purposes, the Caltrans Transportation and Construction Vibration Guidance Manual, (13 p. 38) Table 19, vibration damage are used in this noise study to assess potential temporary construction-related impacts at adjacent building locations. The nearest noise sensitive buildings adjacent to the Project site can best be described as “older residential structures” with a maximum acceptable continuous vibration threshold of 0.3 PPV (in/sec).
3.6 AIRPORT LAND USE COMPATIBILITY
The Project site is located approximately 2.4 miles south of the Ontario International Airport (ONT). This places the Project site within the ONT Airport Influence Area according to Policy Map 2-1 of the Ontario International Airport Land Use Compatibility Plan (ONT ALUCP). The ONT ALUCP was amended July 2018 to promote compatibility between airport and the land uses that surround it (14). Since the Project site is located within the ONT Airport Influence Area, the Project is subject to the Noise Criteria established on Table 2-3 in the ONT ALUCP. As shown on Exhibit 3-B, the Project site is located within the ONT Airport Influence Area but outside the 60 dBA CNEL airport noise impact zone consistent with Policy Map 2-3. According to Table 2-3 of the ONT ALUCP, the Rich-Haven Specific Plan-2022 Amendment, residential, commercial, light industrial and community facilities land uses located outside the 60 dBA CNEL, are considered normally compatible land use. For normally compatible land use, either the activities associated with the land use are inherently noisy or standard construction methods will sufficiently attenuate exterior noise to an acceptable indoor community noise equivalent level (CNEL). 5940
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
19 EXHIBIT 3-B: ONT FUTURE AIRPORT NOISE CONTOURS
5941
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
20 This page intentionally left blank
5942
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
21 4 SIGNIFICANCE CRITERIA
The following significance criteria are based on currently adopted guidance provided by Appendix G of the California Environmental Quality Act (CEQA) Guidelines. (1) For the purposes of this report, impacts would be potentially significant if the Project results in or causes:
A. Generation of a substantial temporary or permanent increase in ambient noise levels in the vicinity of the project in excess of standards established in the local general plan or noise ordinance, or applicable standards of other agencies?
B. Generation of excessive ground-borne vibration or ground-borne noise levels? C. For a project located within the vicinity of a private airstrip or an airport land use plan or, where such a plan has not been adopted, within two miles of a public airport or public use airport, would the project expose people residing or working in the project area to excessive noise levels?
4.1 NOISE LEVEL INCREASES (THRESHOLD A)
Noise level increases resulting from the Project are evaluated based on the Appendix G CEQA Guidelines described above at the closest sensitive receiver locations. Under CEQA, consideration must be given to the magnitude of the increase, the existing baseline ambient noise levels, and the location of noise-sensitive receivers to determine if a noise increase represents a significant adverse environmental impact. This approach recognizes that there is no single noise increase that renders the noise impact significant. (16) This is primarily because of the wide variation in individual thresholds of annoyance and differing individual experiences with noise. Thus, an important way of determining a person’s subjective reaction to a new noise is the comparison of it to the existing environment to which one has adapted—the so-called ambient environment. In general, the more a new noise exceeds the previously existing ambient noise level, the less acceptable the new noise will typically be judged.
4.1.1 NOISE-SENSITIVE RECEIVERS
The Federal Interagency Committee on Noise (FICON) (17) developed guidance to be used for the assessment of project-generated increases in noise levels that consider the ambient noise level.
The FICON recommendations are based on studies that relate aircraft noise levels to the percentage of persons highly annoyed by aircraft noise. Although the FICON recommendations were specifically developed to assess aircraft noise impacts, these recommendations are often used in environmental noise impact assessments involving the use of cumulative noise exposure metrics, such as the average-daily noise level (CNEL) and equivalent continuous noise level (Leq).
As previously stated, the approach used in this noise study recognizes that there is no single noise increase that renders the noise impact significant, based on a 2008 California Court of Appeal ruling on Gray v. County of Madera. (16) For example, if the ambient noise environment is quiet (<60 dBA) and the new noise source greatly increases the noise levels, an impact may occur if the noise criteria may be exceeded. Therefore, for this analysis, a readily perceptible 5 dBA or greater project-related noise level increase is considered a significant impact when the without project noise levels are below 60 dBA. Per the FICON, in areas where the without project noise levels 5943
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
22 range from 60 to 65 dBA, a 3 dBA barely perceptible noise level increase appears to be appropriate for most people. When the without project noise levels already exceed 65 dBA, any increase in community noise louder than 1.5 dBA or greater is considered a significant impact if the noise criteria for a given land use is exceeded, since it likely contributes to an existing noise exposure exceedance. The FICON guidance provides an established source of criteria to assess the impacts of substantial temporary or permanent increase in baseline ambient noise levels.
Based on the FICON criteria, the amount to which a given noise level increase is considered acceptable is reduced when the without Project (baseline) noise levels are already shown to exceed certain land-use specific exterior noise level criteria. The specific levels are based on typical responses to noise level increases of 5 dBA or readily perceptible, 3 dBA or barely perceptible, and 1.5 dBA depending on the underlying without Project noise levels for noisesensitive uses. These levels of increases and their perceived acceptance are consistent with guidance provided by both the Federal Highway Administration (4 p. 9) and Caltrans (18 p. 2_48).
4.1.2 NON-NOISE-SENSITIVE RECEIVERS
The Ontario Noise Level Exposure and Land Use Compatibility Guidelines were used to establish the satisfactory noise levels of significance for the non-noise-sensitive land uses in the Project study area. As previously shown on Exhibit 3-A, the normally acceptable exterior noise level for non-noise-sensitive general industrial land uses is 75 dBA CNEL. Noise levels greater than 75 dBA CNEL are considered normally unacceptable. (10)
To determine if Project-related traffic noise level increases are significant at off-site non-noisesensitive general industrial land uses, a barely perceptible 3 dBA criteria is used. When the without Project noise levels are greater than the normally acceptable 75 dBA CNEL land use compatibility criteria, a barely perceptible 3 dBA or greater noise level increase is considered a significant impact since the noise level criteria is already exceeded. The noise level increases used to determine significant impacts for non-noise-sensitive land uses is generally consistent with the FICON noise level increase thresholds for noise-sensitive land uses but instead rely on Ontario Noise Level Exposure and Land Use Compatibility Guidelines normally acceptable 75 dBA CNEL exterior noise level criteria for non-noise sensitive general industrial land uses.
4.2 VIBRATION (THRESHOLD B)
As described in Section 3.5, the vibration impacts originating from the construction of the RichHaven Specific Plan-2022 Amendment, vibration-generating activities are appropriately evaluated using the Caltrans vibration damage thresholds to assess potential temporary construction-related impacts at adjacent building locations. The nearest noise sensitive buildings adjacent to the Project site can best be described as “older residential structures” with a maximum acceptable continuous vibration threshold of 0.3 PPV (in/sec).
4.3 CEQAGUIDELINES NOT FURTHER ANALYZED (THRESHOLD C)
CEQA Noise Threshold C applies when there are nearby public and private airports and/or air strips and focuses on land use compatibility of the Project to nearby airports and airstrips. The closest airport which would require additional noise analysis under CEQA guideline C is the 5944
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
23 Ontario International Airport. As previously indicated in Section 3.6, the Project site is located within the ONT Airport Influence Area but is located outside the 60 dBA CNEL airport noise impact zone. Therefore, airport noise impacts are considered less than significant, and no further noise analysis is provided under Guideline C.
4.4 SIGNIFICANCE CRITERIA SUMMARY
Noise impacts shall be considered significant if any of the following occur as a direct result of the proposed development. Table 4-1 shows the significance criteria summary matrix that includes the allowable criteria used to identify potentially significant incremental noise level increases.
TABLE 4-1: SIGNIFICANCE CRITERIA SUMMARY
Analysis Land Use Condition(s)
Significance Criteria
Daytime Nighttime
Off-Site
NoiseSensitive1
if ambient is < 60 dBA CNEL ≥ 5 dBA CNEL Project increase if ambient is 60 - 65 dBA CNEL ≥ 3 dBA CNEL Project increase if ambient is > 65 dBA CNEL ≥ 1.5 dBA CNEL Project increase Non-Noise
Sensitive2
if ambient is > 75 dBA CNEL ≥ 3 dBA CNEL Project increase Operational
Residential Exterior Noise Level Limit3 55 dBA Leq 45 dBA Leq NoiseSensitive1
if ambient is < 60 dBA Leq ≥ 5 dBA Leq Project increase if ambient is 60 - 65 dBA Leq ≥ 3 dBA Leq Project increase if ambient is > 65 dBA Leq ≥ 1.5 dBA Leq Project increase Construction NoiseSensitive
Noise Level Threshold4 80 dBA Leq 70 dBA Leq
Vibration Level Threshold5 0.3 PPV (in/sec) n/a
1 FICON, 1992.
2 Table 5-13-3 of The Ontario Plan 2050 Final Supplemental Environmental Impact Report (FSEIR) (Exhibit 3-A) 3 City of Ontario Municipal Code Section 5-29.09(a)(Appendix 3.2) 4 Federal Transit Administration, Transit Noise and Vibration Impact Assessment Manual. 5 Caltrans Transportation and Construction Vibration Manual, April 2020 Table 19. "Daytime" = 7:00 a.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m. "n/a" = construction activities are not planned during the nighttime hours; "PPV" = peak particle velocity.
5945
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
24 This page intentionally left blank
5946
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
25 5 EXISTING NOISE LEVEL MEASUREMENTS
To assess the existing noise level environment, 24-hour noise level measurements were taken at eight locations in the Project study area. The receiver locations were selected to describe and document the existing noise environment within the Project study area. Exhibit 5-A provides the boundaries of the Project study area and the noise level measurement locations. To fully describe the existing noise conditions, noise level measurements were collected by Urban Crossroads, Inc. on Friday, September 30, 2022. Appendix 5.1 includes study area photos.
5.1 MEASUREMENT PROCEDURE AND CRITERIA
To describe the existing noise environment, the hourly noise levels were measured during typical weekday conditions over a 24-hour period. By collecting individual hourly noise level measurements, it is possible to describe the daytime and nighttime hourly noise levels and calculate the 24-hour CNEL. The long-term noise readings were recorded using Piccolo Type 2 integrating sound level meter and dataloggers. The Piccolo sound level meters were calibrated using a Larson-Davis calibrator, Model CAL 150. All noise meters were programmed in "slow" mode to record noise levels in "A" weighted form. The sound level meters and microphones were equipped with a windscreen during all measurements. All noise level measurement equipment satisfies the American National Standards Institute (ANSI) standard specifications for sound level meters ANSI S1.4-2014/IEC 61672-1:2013. (19)
5.2 NOISE MEASUREMENT LOCATIONS
The long-term noise level measurements were positioned as close to the nearest sensitive receiver locations as possible to assess the existing ambient hourly noise levels surrounding the Project site. Both Caltrans and the FTA recognize that it is not reasonable to collect noise level measurements that can fully represent every part of a private yard, patio, deck, or balcony normally used for human activity when estimating impacts for new development projects. This is demonstrated in the Caltrans general site location guidelines which indicate that, sites must be free of noise contamination by sources other than sources of interest. Avoid sites located near sources such as barking dogs, lawnmowers, pool pumps, and air conditioners unless it is the express intent of the analyst to measure these sources. (2) Further, FTA guidance states, that it is not necessary nor recommended that existing noise exposure be determined by measuring at every noise-sensitive location in the project area. Rather, the recommended approach is to characterize the noise environment for clusters of sites based on measurements or estimates at representative locations in the community. (8)
Based on recommendations of Caltrans and the FTA, it is not necessary to collect measurements at each individual building or residence, because each receiver measurement represents a group of buildings that share acoustical equivalence. (8) In other words, the area represented by the receiver shares similar shielding, terrain, and geometric relationship to the reference noise source. Receivers represent a location of noise sensitive areas and are used to estimate the future noise level impacts. Collecting reference ambient noise level measurements at the nearby sensitive receiver locations allows for a comparison of the before and after Project noise levels 5947
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
26 and is necessary to assess potential noise impacts due to the Project’s contribution to the ambient noise levels.
5.3 NOISE MEASUREMENT RESULTS
The noise measurements presented below focus on the average or equivalent sound levels (Leq).
The equivalent sound level (Leq) represents a steady state sound level containing the same total energy as a time varying signal over a given sample period. Table 5-1 identifies the hourly daytime (7:00 a.m. to 10:00 p.m.) and nighttime (10:00 p.m. to 7:00 a.m.) noise levels at each noise level measurement location.
TABLE 5-1: 24-HOUR AMBIENT NOISE LEVEL MEASUREMENTS
Location1 Description
Energy Average
Noise Level
(dBA Leq)
2 Daytime Nighttime
L1 Located near the northwest corner of the Project Site near the Colony High School Football Field 56.0 55.6
L2 Located east of the Project Site just south of the
existing residence at 3271 S Quincy Way. 48.9 48.4
L3 Located within the Rich Haven Specific Plan north of Ontario Ranch Road. 69.1 64.0
L4 Located south of the Project Site near the existing
residence at 10823 Edison Avenue. 56.3 52.1
L5 Located within the Rich Haven Specific Plan near the existing residence at 3965 S Sunrise Avenue. 63.1 55.1
L6 Located west of the Project Site near the existing
residence at 3860 S Oasis Paseo 68.8 62.4
L7 Located west of the Project Site near the existing
residence at 3393 Clover Place 65.4 60.2
L8 Located north of the Project Site near the existing
residence at 2943 S Alder Creek Drive. 68.5 64.3
1 See Exhibit 5-A for the noise level measurement locations. 2 Energy (logarithmic) average levels. The long-term 24-hour measurement worksheets are included in Appendix 5.2. "Daytime" = 7:00 a.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m.
Table 5-1 provides the (energy average) noise levels used to describe the daytime and nighttime ambient conditions. These daytime and nighttime energy average noise levels represent the average of all hourly noise levels observed during these time periods expressed as a single number. Appendix 5.2 provides summary worksheets of the noise levels for each hour as well as the minimum, maximum, L1, L2, L5, L8, L25, L50, L90, L95, and L99 percentile noise levels observed during the daytime and nighttime periods.
5948
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
27 EXHIBIT 5-A: NOISE MEASUREMENT LOCATIONS
5949
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
28 This page intentionally left blank
5950
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
29 6 TRAFFIC NOISE METHODS AND PROCEDURES
The following section outlines the methods and procedures used to estimate and analyze the future traffic noise environment. Consistent with City of Ontario Noise Level Exposure and Land Use Compatibility Guidelines (see Exhibit 3-A), all transportation related noise levels are presented in terms of the 24-hour CNEL’s.
6.1 FHWA TRAFFIC NOISE PREDICTION MODEL
The expected roadway noise level increases from vehicular traffic were calculated by Urban Crossroads, Inc. using a computer program that replicates the Federal Highway Administration (FHWA) Traffic Noise Prediction Model- FHWA-RD-77-108. (20) The FHWA Model arrives at a predicted noise level through a series of adjustments to the Reference Energy Mean Emission Level (REMEL). In California the national REMELs are substituted with the California Vehicle Noise (Calveno) Emission Levels. (21) Adjustments are then made to the REMEL to account for: the roadway classification (e.g., collector, secondary, major or arterial), the roadway active width (i.e., the distance between the center of the outermost travel lanes on each side of the roadway), the total average daily traffic (ADT), the travel speed, the percentages of automobiles, medium trucks, and heavy trucks in the traffic volume, the roadway grade, the angle of view (e.g., whether the roadway view is blocked), the site conditions ("hard" or "soft" relates to the absorption of the ground, pavement, or landscaping), and the percentage of total ADT which flows each hour throughout a 24-hour period. Research conducted by Caltrans has shown that the use of soft site conditions is appropriate for the application of the FHWA traffic noise prediction model used in this analysis. (22)
6.1.1 OFF-SITE TRAFFIC NOISE PREDICTION MODEL INPUTS
Table 6-1 presents the roadway parameters used to assess the Project’s off-site transportation noise impacts. Table 6-1 identifies the 18 off-site study area roadway segments, the distance from the centerline to adjacent land use based on the functional roadway classifications per the City of Ontario General Plan and Circulation Element, and the posted vehicle speeds. The ADT volumes used in this study area presented on Table 6-2 are based on Rich-Haven Specific Plan2022 Amendment Traffic Analysis, prepared by Urban Crossroads, Inc. for the following traffic scenarios. (23)
• Existing 2022 Traffic Conditions
• Existing Plus Project 2022 Traffic Conditions
• Opening Year Cumulative (OYC) 2027 Without Project
• Opening Year Cumulative (OYC) 2027 With Project
• Horizon Year (HY) 2050 Without Project
• Horizon Year (HY) 2050 With Project
5951
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
30 The ADT volumes vary for each roadway segment based on the existing traffic volumes and the combination of project traffic distributions. This analysis relies on a comparative evaluation of the off-site traffic noise impacts at the boundary of the right-of-way of the receiving adjacent land use, without and with project ADT traffic volumes from the Project traffic study.
TABLE 6-1: OFF-SITE ROADWAY PARAMETERS
ID Roadway Segment Classification1 Receiving
Land Use2
Distance
from
Centerline to
Receiving
Land Use
(Feet)3
Vehicle
Speed
(mph)
1 Archibald Av. n/o Ontario Ranch Rd. Principal Arterial Sensitive 60' 55 2 Haven Av. n/o Riverside Dr. Principal Arterial Sensitive 60' 55 3 Haven Av. s/o Riverside Dr. Principal Arterial Sensitive 50' 50 4 Haven Av. n/o Ontario Ranch Rd. Principal Arterial Sensitive 50' 50 5 Mill Creek Av. s/o Chino Av. Collector Sensitive 44' 45 6 Milliken Av. n/o Riverside Dr. Principal Arterial Non-Sensitive 60' 55 7 Milliken Av. s/o Riverside Dr. Principal Arterial Non-Sensitive 60' 55 8 Hamner Av. s/o Chino Av. Principal Arterial Non-Sensitive 60' 55 9 Hamner Av. s/o Ontario Ranch Rd. Principal Arterial Non-Sensitive 60' 55 10 Riverside Dr. w/o Haven Av. Minor Arterial Sensitive 60' 50 11 Riverside Dr. w/o Milliken Av. Minor Arterial Sensitive 60' 50 12 Chino Av. e/o Archibald Av. Collector Sensitive 44' 40 13 Ontario Ranch Rd. w/o Archibald Av. Principal Arterial Sensitive 84' 55 14 Ontario Ranch Rd. e/o Archibald Av. Principal Arterial Sensitive 84' 55 15 Ontario Ranch Rd. w/o Haven Av. Principal Arterial Sensitive 84' 55 16 Ontario Ranch Rd. e/o Haven Av. Principal Arterial Sensitive 84' 55 17 Ontario Ranch Rd. w/o Hamner Av. Principal Arterial Non-Sensitive 84' 55 18 Ontario Ranch Rd. e/o Hamner Av. Principal Arterial Non-Sensitive 84' 55 1 City of Ontario General Plan Circulation Element.
2 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 3 Distance to receiving land use is based upon the right-of-way distances.
To quantify the off-site noise levels, the Project related truck trips were added to the heavy truck category in the FHWA noise prediction model. The addition of the Project related truck trips increases the percentage of heavy trucks in the vehicle mix. This approach recognizes that the FHWA noise prediction model is significantly influenced by the number of heavy trucks in the vehicle mix.
5952
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
31 TABLE 6-2: AVERAGE DAILY TRAFFIC VOLUMES
ID Roadway Segment
Average Daily Traffic Volumes1
Existing (2022) OYC (2027) HY (2050)
Without
Project
With
Project
Without
Project
With
Project
Without
Project
With
Project
1 Archibald Av. n/o Ontario Ranch Rd. 21,909 26,968 26,337 31,396 37,904 42,963 2 Haven Av. n/o Riverside Dr. 18,527 34,509 26,968 42,951 33,655 49,637 3 Haven Av. s/o Riverside Dr. 10,432 28,244 20,983 38,795 28,411 46,224 4 Haven Av. n/o Ontario Ranch Rd. 13,491 40,050 18,453 45,012 24,005 50,564 5 Mill Creek Av. s/o Chino Av. 2,866 9,207 3,164 9,505 7,391 13,732 6 Milliken Av. n/o Riverside Dr. 19,818 33,876 22,416 36,475 53,343 67,401 7 Milliken Av. s/o Riverside Dr. 18,436 28,604 21,431 31,599 41,531 51,699 8 Hamner Av. s/o Chino Av. 18,514 28,300 20,979 30,765 42,863 52,650 9 Hamner Av. s/o Ontario Ranch Rd. 26,376 34,332 29,827 37,783 31,170 39,126 10 Riverside Dr. w/o Haven Av. 15,880 17,898 18,998 21,016 32,988 35,006 11 Riverside Dr. w/o Milliken Av. 9,308 16,275 13,501 20,468 36,188 43,155 12 Chino Av. e/o Archibald Av. 5,409 8,054 9,529 12,173 11,003 13,647 13 Ontario Ranch Rd. w/o Archibald Av. 13,582 20,888 16,875 24,182 18,501 25,807 14 Ontario Ranch Rd. e/o Archibald Av. 16,280 33,653 19,855 37,228 19,774 37,147 15 Ontario Ranch Rd. w/o Haven Av. 18,294 39,277 22,078 43,061 52,058 73,041 16 Ontario Ranch Rd. e/o Haven Av. 23,755 49,864 27,304 53,412 41,417 67,526 17 Ontario Ranch Rd. w/o Hamner Av. 22,522 54,967 33,350 65,795 45,327 77,772 18 Ontario Ranch Rd. e/o Hamner Av. 27,822 51,979 38,968 63,124 50,098 74,255 1 Rich Haven Specific Plan Traffic Analysis, Urban Crossroads, Inc.
Table 6-3 provides the time of day (daytime, evening, and nighttime) vehicle splits. The daily Project truck trip-ends were assigned to the individual off-site study area roadway segments based on the Project truck trip distribution percentages documented in the Rich-Haven Specific Plan-2022 Amendment Traffic Analysis.
TABLE 6-3: TIME OF DAY VEHICLE SPLITS
Vehicle Type
Time of Day Splits1
Total of Time of
Daytime Evening Nighttime Day Splits
Autos 70.72% 11.77% 17.51% 100.00%
Medium Trucks 82.20% 3.49% 14.31% 100.00%
Heavy Trucks 70.82% 6.23% 22.95% 100.00%
1 Based on an existing vehicle count taken on Ontario Ranch Road west of Hamner Avenue (Rich Haven Specific Plan Traffic Analysis, Urban Crossroads, Inc.). Vehicle mix percentage values rounded to the nearest one-hundredth. "Daytime" = 7:00 a.m. to 7:00 p.m.; "Evening" = 7:00 p.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m. 5953
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
32 Using the Project truck trips in combination with the Project trip distribution, Urban Crossroads, Inc. calculated the number of additional Project truck trips and vehicle mix percentages for each of the study area roadway segments. Table 6-4 shows the traffic flow by vehicle type (vehicle mix) used for all without Project traffic scenarios, and Tables 6-5 to 6-7 show the vehicle mixes used for the with Project traffic scenarios.
TABLE 6-4: WITHOUT PROJECT VEHICLE MIX
Classification
Total % Traffic Flow
Total
Autos Medium Trucks Heavy Trucks
All Segments 86.53% 2.42% 11.05% 100.00%
Based on an existing vehicle count taken on Ontario Ranch Road west of Hamner Avenue (Rich Haven Specific Plan Traffic Analysis, Urban Crossroads, Inc.) Vehicle mix percentage values rounded to the nearest one-hundredth.
Due to the added Project truck trips, the increase in Project traffic volumes and the distributions of trucks on the study area road segments, the percentage of autos, medium trucks and heavy trucks will vary for each of the traffic scenarios. This explains why the existing and future traffic volumes and vehicle mixes vary between seemingly identical study area roadway segments.
TABLE 6-5: EXISTING (2022) WITH PROJECT VEHICLE MIX
ID Roadway Segment
With Project1
Autos Medium
Trucks
Heavy
Trucks Total2
1 Archibald Av. n/o Ontario Ranch Rd. 89.06% 1.97% 8.97% 100.00% 2 Haven Av. n/o Riverside Dr. 92.77% 1.30% 5.93% 100.00% 3 Haven Av. s/o Riverside Dr. 95.03% 0.89% 4.08% 100.00% 4 Haven Av. n/o Ontario Ranch Rd. 95.46% 0.82% 3.72% 100.00% 5 Mill Creek Av. s/o Chino Av. 95.81% 0.75% 3.44% 100.00% 6 Milliken Av. n/o Riverside Dr. 91.28% 1.55% 7.17% 100.00% 7 Milliken Av. s/o Riverside Dr. 90.32% 1.72% 7.96% 100.00% 8 Hamner Av. s/o Chino Av. 90.18% 1.74% 8.08% 100.00%
9 Hamner Av. s/o Ontario Ranch Rd. 89.65% 1.86% 8.49% 100.00% 10 Riverside Dr. w/o Haven Av. 88.05% 2.15% 9.80% 100.00% 11 Riverside Dr. w/o Milliken Av. 92.30% 1.38% 6.32% 100.00% 12 Chino Av. e/o Archibald Av. 90.95% 1.63% 7.42% 100.00% 13 Ontario Ranch Rd. w/o Archibald Av. 90.42% 1.70% 7.87% 100.00% 14 Ontario Ranch Rd. e/o Archibald Av. 92.98% 1.25% 5.77% 100.00% 15 Ontario Ranch Rd. w/o Haven Av. 93.29% 1.20% 5.51% 100.00% 16 Ontario Ranch Rd. e/o Haven Av. 93.24% 1.21% 5.55% 100.00% 17 Ontario Ranch Rd. w/o Hamner Av. 93.13% 1.21% 5.66% 100.00% 18 Ontario Ranch Rd. e/o Hamner Av. 91.47% 1.51% 7.02% 100.00% 1 Total of vehicle mix percentage values rounded to the nearest one-hundredth. 5954
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
33 TABLE 6-6: OYC (2027) WITH PROJECT VEHICLE MIX
ID Roadway Segment
With Project1
Autos Medium
Trucks
Heavy
Trucks Total2
1 Archibald Av. n/o Ontario Ranch Rd. 88.70% 2.03% 9.27% 100.00% 2 Haven Av. n/o Riverside Dr. 91.54% 1.52% 6.94% 100.00% 3 Haven Av. s/o Riverside Dr. 92.72% 1.31% 5.97% 100.00% 4 Haven Av. n/o Ontario Ranch Rd. 94.48% 0.99% 4.53% 100.00% 5 Mill Creek Av. s/o Chino Av. 95.52% 0.81% 3.68% 100.00% 6 Milliken Av. n/o Riverside Dr. 90.94% 1.61% 7.45% 100.00% 7 Milliken Av. s/o Riverside Dr. 89.96% 1.79% 8.25% 100.00% 8 Hamner Av. s/o Chino Av. 89.89% 1.80% 8.31% 100.00%
9 Hamner Av. s/o Ontario Ranch Rd. 89.37% 1.91% 8.72% 100.00% 10 Riverside Dr. w/o Haven Av. 87.83% 2.19% 9.99% 100.00% 11 Riverside Dr. w/o Milliken Av. 91.12% 1.60% 7.29% 100.00% 12 Chino Av. e/o Archibald Av. 89.46% 1.89% 8.65% 100.00% 13 Ontario Ranch Rd. w/o Archibald Av. 89.89% 1.80% 8.31% 100.00% 14 Ontario Ranch Rd. e/o Archibald Av. 92.36% 1.36% 6.28% 100.00% 15 Ontario Ranch Rd. w/o Haven Av. 92.70% 1.30% 6.00% 100.00% 16 Ontario Ranch Rd. e/o Haven Av. 92.79% 1.29% 5.92% 100.00% 17 Ontario Ranch Rd. w/o Hamner Av. 92.04% 1.41% 6.55% 100.00% 18 Ontario Ranch Rd. e/o Hamner Av. 90.60% 1.67% 7.73% 100.00% 1 Total of vehicle mix percentage values rounded to the nearest one-hundredth. 5955
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
34 TABLE 6-7: HY (2050) WITH PROJECT VEHICLE MIX
ID Roadway Segment
With Project1
Autos Medium
Trucks
Heavy
Trucks Total2
1 Archibald Av. n/o Ontario Ranch Rd. 88.12% 2.14% 9.75% 100.00% 2 Haven Av. n/o Riverside Dr. 90.87% 1.64% 7.49% 100.00% 3 Haven Av. s/o Riverside Dr. 91.72% 1.49% 6.79% 100.00% 4 Haven Av. n/o Ontario Ranch Rd. 93.61% 1.15% 5.24% 100.00% 5 Mill Creek Av. s/o Chino Av. 92.75% 1.30% 5.95% 100.00% 6 Milliken Av. n/o Riverside Dr. 88.92% 1.98% 9.10% 100.00% 7 Milliken Av. s/o Riverside Dr. 88.63% 2.03% 9.34% 100.00% 8 Hamner Av. s/o Chino Av. 88.49% 2.06% 9.45% 100.00%
9 Hamner Av. s/o Ontario Ranch Rd. 89.27% 1.93% 8.80% 100.00% 10 Riverside Dr. w/o Haven Av. 87.31% 2.28% 10.41% 100.00% 11 Riverside Dr. w/o Milliken Av. 88.71% 2.03% 9.26% 100.00% 12 Chino Av. e/o Archibald Av. 89.14% 1.95% 8.91% 100.00% 13 Ontario Ranch Rd. w/o Archibald Av. 89.68% 1.84% 8.48% 100.00% 14 Ontario Ranch Rd. e/o Archibald Av. 92.37% 1.36% 6.27% 100.00% 15 Ontario Ranch Rd. w/o Haven Av. 90.17% 1.76% 8.07% 100.00% 16 Ontario Ranch Rd. e/o Haven Av. 91.49% 1.52% 6.99% 100.00% 17 Ontario Ranch Rd. w/o Hamner Av. 91.20% 1.56% 7.24% 100.00% 18 Ontario Ranch Rd. e/o Hamner Av. 89.99% 1.78% 8.23% 100.00% 1 Total of vehicle mix percentage values rounded to the nearest one-hundredth. 5956
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
35 7 OFF-SITE TRAFFIC NOISE ANALYSIS
To assess the off-site transportation CNEL noise level impacts associated with development of the proposed Project, noise contours were developed based on the Rich-Haven Specific Plan2022 Amendment Traffic Analysis prepared by Urban Crossroads, Inc. (23) Noise contour boundaries represent the equal levels of noise exposure and are measured in CNEL from the center of the roadway.
7.1 TRAFFIC NOISE CONTOURS
Noise contours were used to assess the Project's incremental traffic-related noise impacts at land uses adjacent to roadways conveying Project traffic. The noise contours represent the distance to noise levels of a constant value and are measured from the center of the roadway for the 70, 65, and 60 dBA noise levels. The noise contours do not consider the effect of any existing noise barriers or topography that may attenuate ambient noise levels.
In addition, because the noise contours reflect modeling of vehicular noise on area roadways, they appropriately do not reflect noise contributions from the surrounding stationary noise sources within the Project study area. Tables 7-1 to 7-6 present a summary of the exterior traffic noise levels for each traffic condition. Appendix 7.1 includes the traffic noise level contours worksheets for each traffic condition.
TABLE 7-1: EXISTING (2022) WITHOUT PROJECT CONTOURS
ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 79.3 251 542 1167 2 Haven Av. n/o Riverside Dr. Sensitive 78.6 225 484 1043 3 Haven Av. s/o Riverside Dr. Sensitive 76.2 130 281 605 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 77.4 155 333 718 5 Mill Creek Av. s/o Chino Av. Sensitive 69.7 RW 90 195 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 78.9 235 507 1091 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 78.6 224 483 1040 8 Hamner Av. s/o Chino Av. Non-Sensitive 78.6 225 484 1043 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.1 284 613 1320 10 Riverside Dr. w/o Haven Av. Sensitive 77.2 182 391 843 11 Riverside Dr. w/o Milliken Av. Sensitive 74.9 127 274 590 12 Chino Av. e/o Archibald Av. Sensitive 71.1 52 112 240 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 79.1 340 733 1578 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 79.9 384 827 1781 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 80.4 415 894 1925 5957
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
36 ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
16 Ontario Ranch Rd. e/o Haven Av. Sensitive 81.5 494 1064 2291 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 81.3 476 1026 2211 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 82.2 549 1182 2546 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road.
TABLE 7-2: EXISTING (2022) WITH PROJECT CONTOURS
ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 79.5 259 559 1204 2 Haven Av. n/o Riverside Dr. Sensitive 79.3 251 541 1166 3 Haven Av. s/o Riverside Dr. Sensitive 77.5 157 339 729 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 78.7 191 412 887 5 Mill Creek Av. s/o Chino Av. Sensitive 71.1 52 112 241 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 79.8 271 583 1257 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 79.4 254 548 1180 8 Hamner Av. s/o Chino Av. Non-Sensitive 79.4 254 548 1180 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.4 296 639 1376 10 Riverside Dr. w/o Haven Av. Sensitive 77.3 185 398 857 11 Riverside Dr. w/o Milliken Av. Sensitive 75.5 139 300 645 12 Chino Av. e/o Archibald Av. Sensitive 71.4 54 117 252 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 79.9 382 822 1771 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 81.0 454 978 2108 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 81.5 493 1063 2290 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 82.6 580 1250 2693 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 83.1 624 1345 2897 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 83.5 663 1429 3079 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road. 5958
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
37 TABLE 7-3: OYC (2027) WITHOUT PROJECT CONTOURS
ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 80.1 284 612 1319 2 Haven Av. n/o Riverside Dr. Sensitive 80.2 289 622 1340 3 Haven Av. s/o Riverside Dr. Sensitive 79.3 208 447 963 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 78.7 191 410 884 5 Mill Creek Av. s/o Chino Av. Sensitive 70.1 45 97 208 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 79.4 255 550 1185 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 79.2 248 534 1150 8 Hamner Av. s/o Chino Av. Non-Sensitive 79.1 244 526 1133 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.7 309 665 1433 10 Riverside Dr. w/o Haven Av. Sensitive 78.0 205 441 950 11 Riverside Dr. w/o Milliken Av. Sensitive 76.5 163 351 757 12 Chino Av. e/o Archibald Av. Sensitive 73.5 76 163 350 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 80.1 393 847 1824 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 80.8 438 944 2033 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 81.2 470 1013 2182 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 82.1 542 1167 2514 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 83.0 619 1333 2873 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 83.7 687 1479 3187 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road.
TABLE 7-4: OYC (2027) WITH PROJECT CONTOURS
ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 80.3 292 629 1355 2 Haven Av. n/o Riverside Dr. Sensitive 80.7 312 673 1450 3 Haven Av. s/o Riverside Dr. Sensitive 79.9 229 494 1065 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 79.8 224 482 1039 5 Mill Creek Av. s/o Chino Av. Sensitive 71.4 55 117 253 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 80.3 290 624 1344 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 80.0 277 596 1284 8 Hamner Av. s/o Chino Av. Non-Sensitive 79.9 273 587 1265 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.9 320 690 1486 5959
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
38 ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
10 Riverside Dr. w/o Haven Av. Sensitive 78.1 207 447 963 11 Riverside Dr. w/o Milliken Av. Sensitive 76.9 174 374 805 12 Chino Av. e/o Archibald Av. Sensitive 73.7 78 167 360 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 80.7 432 930 2004 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 81.7 504 1087 2341 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 82.2 544 1173 2527 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 83.1 625 1346 2900 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 84.3 751 1619 3488 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 84.6 791 1703 3669 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road.
TABLE 7-5: HY (2050) WITHOUT PROJECT CONTOURS
ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 81.7 362 780 1681 2 Haven Av. n/o Riverside Dr. Sensitive 81.2 335 721 1553 3 Haven Av. s/o Riverside Dr. Sensitive 80.6 254 547 1179 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 79.9 227 489 1054 5 Mill Creek Av. s/o Chino Av. Sensitive 73.8 79 170 366 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 83.2 455 980 2112 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 82.1 385 829 1787 8 Hamner Av. s/o Chino Av. Non-Sensitive 82.2 393 847 1825 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.9 318 685 1476 10 Riverside Dr. w/o Haven Av. Sensitive 80.4 296 637 1372 11 Riverside Dr. w/o Milliken Av. Sensitive 80.8 314 678 1460 12 Chino Av. e/o Archibald Av. Sensitive 74.1 83 179 386 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 80.5 418 900 1940 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 80.7 437 941 2028 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 84.9 833 1794 3866 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 84.0 715 1541 3319 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 84.3 759 1636 3525 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 84.8 812 1749 3768 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road. 5960
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
39 TABLE 7-6: HY (2050) WITH PROJECT CONTOURS
ID Road Segment Receiving
Land Use1
CNEL at
Receiving
Land Use
(dBA)2
Distance to Contour from
Centerline (Feet)
70 dBA
CNEL
65 dBA
CNEL
60 dBA
CNEL
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 81.8 369 795 1713 2 Haven Av. n/o Riverside Dr. Sensitive 81.6 357 768 1655 3 Haven Av. s/o Riverside Dr. Sensitive 81.1 274 590 1271 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 80.7 258 556 1197 5 Mill Creek Av. s/o Chino Av. Sensitive 74.4 86 186 401 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 83.6 481 1037 2233 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 82.5 408 880 1896 8 Hamner Av. s/o Chino Av. Non-Sensitive 82.6 416 896 1931 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 81.1 329 709 1528 10 Riverside Dr. w/o Haven Av. Sensitive 80.4 298 642 1383 11 Riverside Dr. w/o Milliken Av. Sensitive 80.9 322 694 1495 12 Chino Av. e/o Archibald Av. Sensitive 74.3 85 183 395 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 81.0 456 982 2115 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 81.7 503 1084 2336 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 85.4 890 1917 4130 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 84.6 788 1698 3659 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 85.3 880 1897 4087 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 85.5 908 1956 4215 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of the receiving adjacent land use. "RW" = Location of the respective noise contour falls within the right-of-way of the road.
7.2 EXISTING (2022) PROJECT TRAFFIC NOISE LEVEL INCREASES An analysis of existing traffic noise levels plus traffic noise generated by the proposed Project has been included in this report for informational purposes and to fully analyze all the existing traffic scenarios identified in the Traffic Analysis prepared by Urban Crossroads, Inc. However, the analysis of existing off-site traffic noise levels plus traffic noise generated by the proposed Project scenario will not actually occur since the Project would not be fully constructed and operational until Year 2027 conditions. Table 7-1 shows the Existing without Project conditions CNEL noise levels. The Existing without Project exterior noise levels range from 69.7 to 82.2 dBA CNEL, without accounting for any noise attenuation features such as noise barriers or topography.
Table 7-2 shows the Existing with Project conditions ranging from 71.1 to 83.5 dBA CNEL. Table 7-7 shows that the Project off-site traffic noise level increases range from 0.1 to 1.8 dBA CNEL on the study area roadway segments. Based on the significance criteria for off-site traffic noise presented in Table 4-1, land uses adjacent to the study area roadway segments would experience less than significant noise level increases on receiving land uses due to the Project-related traffic. 5961
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
40 TABLE 7-7: EXISTING (2022) WITH PROJECT TRAFFIC NOISE LEVEL INCREASES ID Road Segment Receiving
Land Use1
CNEL at Receiving
Land Use (dBA)2
Incremental Noise
Level Increase
Threshold3
No
Project
With
Project
Project
Addition Limit Exceeded?
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 79.3 79.5 0.2 1.5 No 2 Haven Av. n/o Riverside Dr. Sensitive 78.6 79.3 0.7 1.5 No 3 Haven Av. s/o Riverside Dr. Sensitive 76.2 77.5 1.3 1.5 No 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 77.4 78.7 1.3 1.5 No 5 Mill Creek Av. s/o Chino Av. Sensitive 69.7 71.1 1.4 1.5 No 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 78.9 79.8 0.9 3.0 No 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 78.6 79.4 0.8 3.0 No 8 Hamner Av. s/o Chino Av. Non-Sensitive 78.6 79.4 0.8 3.0 No 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.1 80.4 0.3 3.0 No 10 Riverside Dr. w/o Haven Av. Sensitive 77.2 77.3 0.1 1.5 No 11 Riverside Dr. w/o Milliken Av. Sensitive 74.9 75.5 0.6 1.5 No 12 Chino Av. e/o Archibald Av. Sensitive 71.1 71.4 0.3 1.5 No 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 79.1 79.9 0.8 1.5 No 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 79.9 81.0 1.1 1.5 No 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 80.4 81.5 1.1 1.5 No 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 81.5 82.6 1.1 1.5 No 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 81.3 83.1 1.8 3.0 No 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 82.2 83.5 1.3 3.0 No 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of each roadway and the property line of the receiving land use. 3 Does the Project create an incremental noise level increase exceeding the significance criteria (Table 4-1)?
7.3 OYC (2027) TRAFFIC NOISE LEVEL INCREASES
Table 7-3 presents the OYC without Project conditions CNEL noise levels. The OYC without Project exterior noise levels range from 70.1 to 83.7 dBA CNEL, without accounting for any noise attenuation features such as noise barriers or topography. Table 7-4 shows that the OYC with Project conditions will range from 71.4 to 84.6 dBA CNEL. Table 7-8 shows that the Project offsite traffic noise level increases range from 0.1 to 1.3 dBA CNEL. Based on the significance criteria for off-site traffic noise presented in Table 4-1, land uses adjacent to the study area roadway segments would experience less than significant noise level increases on receiving land uses due to the Project-related traffic.
5962
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
41 TABLE 7-8: OYC (2027) WITH PROJECT TRAFFIC NOISE LEVEL INCREASES ID Road Segment Receiving
Land Use1
CNEL at Receiving
Land Use (dBA)2
Incremental Noise
Level Increase
Threshold3
No
Project
With
Project
Project
Addition Limit Exceeded?
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 80.1 80.3 0.2 1.5 No 2 Haven Av. n/o Riverside Dr. Sensitive 80.2 80.7 0.5 1.5 No 3 Haven Av. s/o Riverside Dr. Sensitive 79.3 79.9 0.6 1.5 No 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 78.7 79.8 1.1 1.5 No 5 Mill Creek Av. s/o Chino Av. Sensitive 70.1 71.4 1.3 1.5 No 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 79.4 80.3 0.9 3.0 No 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 79.2 80.0 0.8 3.0 No 8 Hamner Av. s/o Chino Av. Non-Sensitive 79.1 79.9 0.8 3.0 No 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.7 80.9 0.2 3.0 No 10 Riverside Dr. w/o Haven Av. Sensitive 78.0 78.1 0.1 1.5 No 11 Riverside Dr. w/o Milliken Av. Sensitive 76.5 76.9 0.4 1.5 No 12 Chino Av. e/o Archibald Av. Sensitive 73.5 73.7 0.2 1.5 No 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 80.1 80.7 0.6 1.5 No 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 80.8 81.7 0.9 1.5 No 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 81.2 82.2 1.0 1.5 No 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 82.1 83.1 1.0 1.5 No 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 83.0 84.3 1.3 3.0 No 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 83.7 84.6 0.9 3.0 No 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of each roadway and the property line of the receiving land use. 3 Does the Project create an incremental noise level increase exceeding the significance criteria (Table 4-1)?
7.4 HY (2050) TRAFFIC NOISE LEVEL INCREASES
Table 7-5 presents the HY without Project conditions CNEL noise levels. The HY without Project exterior noise levels range from 73.8 to 84.9 dBA CNEL, without accounting for any noise attenuation features such as noise barriers or topography. Table 7-6 shows that the HY with Project conditions will range from 74.3 to 85.5 dBA CNEL. Table 7-8 shows that the Project offsite traffic noise level increases range from 0.0 to 1.0 dBA CNEL. Based on the significance criteria for off-site traffic noise presented in Table 4-1, land uses adjacent to the study area roadway segments would experience less than significant noise level increases on receiving land uses due to the Project-related traffic.
5963
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
42 TABLE 7-9: HY (2050) WITH PROJECT TRAFFIC NOISE LEVEL INCREASES ID Road Segment Receiving
Land Use1
CNEL at Receiving
Land Use (dBA)2
Incremental Noise
Level Increase
Threshold3
No
Project
With
Project
Project
Addition Limit Exceeded?
1 Archibald Av. n/o Ontario Ranch Rd. Sensitive 81.7 81.8 0.1 1.5 No 2 Haven Av. n/o Riverside Dr. Sensitive 81.2 81.6 0.4 1.5 No 3 Haven Av. s/o Riverside Dr. Sensitive 80.6 81.1 0.5 1.5 No 4 Haven Av. n/o Ontario Ranch Rd. Sensitive 79.9 80.7 0.8 1.5 No 5 Mill Creek Av. s/o Chino Av. Sensitive 73.8 74.4 0.6 1.5 No 6 Milliken Av. n/o Riverside Dr. Non-Sensitive 83.2 83.6 0.4 3.0 No 7 Milliken Av. s/o Riverside Dr. Non-Sensitive 82.1 82.5 0.4 3.0 No 8 Hamner Av. s/o Chino Av. Non-Sensitive 82.2 82.6 0.4 3.0 No 9 Hamner Av. s/o Ontario Ranch Rd. Non-Sensitive 80.9 81.1 0.2 3.0 No 10 Riverside Dr. w/o Haven Av. Sensitive 80.4 80.4 0.0 1.5 No 11 Riverside Dr. w/o Milliken Av. Sensitive 80.8 80.9 0.1 1.5 No 12 Chino Av. e/o Archibald Av. Sensitive 74.1 74.3 0.2 1.5 No 13 Ontario Ranch Rd. w/o Archibald Av. Sensitive 80.5 81.0 0.5 1.5 No 14 Ontario Ranch Rd. e/o Archibald Av. Sensitive 80.7 81.7 1.0 1.5 No 15 Ontario Ranch Rd. w/o Haven Av. Sensitive 84.9 85.4 0.5 1.5 No 16 Ontario Ranch Rd. e/o Haven Av. Sensitive 84.0 84.6 0.6 1.5 No 17 Ontario Ranch Rd. w/o Hamner Av. Non-Sensitive 84.3 85.3 1.0 3.0 No 18 Ontario Ranch Rd. e/o Hamner Av. Non-Sensitive 84.8 85.5 0.7 3.0 No 1 Based on a review of existing aerial imagery. Noise sensitive uses limited to existing residential land uses. 2 The CNEL is calculated at the boundary of the right-of-way of each roadway and the property line of the receiving land use. 3 Does the Project create an incremental noise level increase exceeding the significance criteria (Table 4-1)? 5964
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
43 8 ON-SITE TRAFFIC NOISE ANALYSIS
As outlined in Section 7, noise levels at the roadways bordering the proposed project along Haven Avenue, Mill Creek Avenue, Hamner Avenue, Riverside Drive, Chino Avenue and Ontario Ranch Road would have noise levels above 65 dBA. Therefore, on‐site residential land uses located along these roadways would require additional noise attenuation to ensure that noise levels comply with the City’s exterior and interior noise standards of 65 dBA CNEL and 45 dBA CNEL.
As the development phasing would be implemented through the approval of tentative tract maps and development permits, the proposed project would be required to implement noise abatement measure 1.2.4, which requires that an acoustical analysis be required for residential units upon submittal final site design plans. Noise abatement measure 1.2.4 includes providing attenuation measures such as soundwalls or increasing the distance between habitable spaces and roadways. With compliance with noise abatement measures, impacts from roadways noise to on‐site residential homes would be less than significant. 5965
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
44 This page intentionally left blank
5966
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
45 9 RECEIVER LOCATIONS
To assess the potential for long-term operational and short-term construction noise impacts, the following sensitive receiver locations, as shown on Exhibit 9-A, were identified as representative locations for analysis. Sensitive receivers are generally defined as locations where people reside or where the presence of unwanted sound could otherwise adversely affect the use of the land.
Noise-sensitive land uses are generally considered to include schools, hospitals, single-family dwellings, mobile home parks, churches, libraries, and recreation areas. Moderately noisesensitive land uses typically include multi-family dwellings, hotels, motels, dormitories, outpatient clinics, cemeteries, golf courses, country clubs, athletic/tennis clubs, and equestrian clubs. Land uses that are considered relatively insensitive to noise include business, commercial, and professional developments. Land uses that are typically not affected by noise include:
industrial, manufacturing, utilities, agriculture, undeveloped land, parking lots, warehousing, liquid and solid waste facilities, salvage yards, and transit terminals.
To describe the potential off-site Project noise levels, eight receiver locations in the vicinity of the Project site were identified. The selection of receiver locations is based on FHWA guidelines and is consistent with additional guidance provided by Caltrans and the FTA, as previously described in Section 5.2. Other sensitive land uses in the Project study area that are located at greater distances than those identified in this noise study will experience lower noise levels than those presented in this report due to the additional attenuation from distance and the shielding of intervening structures. Distance is measured in a straight line from the project boundary to each receiver location.
R1: Location R1 represents the Colony High School Football Stadium, approximately 76 feet north of the Project site. Receiver R1 is placed in the bleachers just north of Planning Area (PA) 1. A 24-hour noise measurement was taken near this location, L1, to describe the existing ambient noise environment.
R2: Location R2 represents the existing noise sensitive residence at 3271 S Quincy Way, approximately 219 feet east of the Project site. Receiver R2 is placed in the private outdoor living areas facing the Project site. A 24-hour noise measurement was taken near this location, L2, to describe the existing ambient noise environment.
R3: Location R3 represents an on-site receiver location within the planned PA7 residential mixed use overlay area. Receiver R3 is placed approximately 460 feet south of the light industrial use within PA 6A. A 24-hour noise measurement was taken near this location, L3, to describe the existing ambient noise environment.
R4: Location R4 represents the existing noise sensitive residence at 10823 Edison Avenue, approximately 94 feet south of the Project site. Since there are no private outdoor living areas (backyard) facing the Project site, receiver R4 is placed at the building’s façade. A 24-hour noise measurement was taken near this location, L4, to describe the existing ambient noise environment.
5967
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
46 EXHIBIT 9-A: RECEIVER LOCATIONS
5968
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
47 R5: Location R5 represents the existing on-site noise sensitive residence at 3959 S Sunrise Avenue within the standalone residential overlay (PA4). Receiver R5 is placed in the private outdoor living areas facing the light industrial use within PA5A. A 24-hour noise measurement was taken near this location, L5, to describe the existing ambient noise environment.
R6: Location R6 represents the existing noise sensitive residence at 3455 Pine Ridge Loop, approximately 150 feet west of the Project site. Receiver R6 is placed in the private outdoor living areas facing the Project site. A 24-hour noise measurement was taken near this location, L6, to describe the existing ambient noise environment.
R7: Location R7 represents the existing noise sensitive residence at 3379 S Myrtle Drive, approximately 156 feet west of the Project site. Receiver R7 is placed in the private outdoor living areas facing the Project site. A 24-hour noise measurement was taken near this location, L7, to describe the existing ambient noise environment.
R8: Location R8 represents the existing noise sensitive residence at 2943 S Alder Creek Drive, approximately 189 feet north of the Project site. Receiver R8 is placed in the private outdoor living areas facing the Project site. A 24-hour noise measurement was taken near this location, L8, to describe the existing ambient noise environment. 5969
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
48 This page intentionally left blank
5970
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
49 10 OPERATIONAL NOISE ANALYSIS
This section analyzes the potential stationary-source operational noise impacts at the nearby receiver locations, identified in Section 9, resulting from the operation of the proposed RichHaven Specific Plan-2022 Amendment Project. It is expected that the primary noise source activities will be related to the light industrial and commercial land uses within planning areas 2C, 3C, 5A, 6A, 6B, 8 and 10B. The residential planning areas within the Rich-Haven Specific Plan2022 Amendment are considered a noise-sensitive receiving land use. Therefore, no potential operational noise impacts for the residential land use are analyzed in the noise study. Exhibit 10- A identifies the noise source locations used to assess the operational noise levels.
10.1 OPERATIONAL NOISE SOURCES
This operational noise analysis is intended to describe noise level impacts associated with the expected typical of daytime and nighttime activities at the Project site. To present the potential worst-case noise conditions, this analysis assumes the Project would be operational 24 hours per day, seven days per week. The on-site Project-related noise sources are expected to include:
loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, truck movements and park activities.
10.2 REFERENCE NOISE LEVELS
To estimate the Project operational noise impacts, reference noise level measurements were collected from similar types of activities to represent the noise levels expected with the development of the proposed Project. This section provides a detailed description of the reference noise level measurements shown on Table 10-1 used to estimate the Project operational noise impacts. It is important to note that the following projected noise levels assume the worst-case noise environment with the loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, truck movements and park activities all operating at the same time. These sources of noise activity will likely vary throughout the day.
10.2.1 MEASUREMENT PROCEDURES
The reference noise level measurements presented in this section were collected using a Larson Davis LxT Type 1 precisions sound level meter (serial number 01146). The LxT sound level meter was calibrated using a Larson-Davis calibrator, Model CAL 200, was programmed in "slow" mode to record noise levels in "A" weighted form and was located at approximately five feet above the ground elevation for each measurement. The sound level meters and microphones were equipped with a windscreen during all measurements. All noise level measurement equipment satisfies the American National Standards Institute (ANSI) standard specifications for sound level meters ANSI S1.4-2014/IEC 61672-1:2013. (19)
5971
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
50 EXHIBIT 10-A: OPERATIONAL NOISE SOURCE LOCATIONS
5972
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
51 TABLE 10-1: REFERENCE NOISE LEVEL MEASUREMENTS
Noise Source1
Noise
Source
Height
(Feet)
Min./
Hour2
Reference
Noise Level
(dBA Leq)
@ 50 Feet
Sound
Power
Level
(dBA) Day Night 3
Loading Dock Activity 8' 60 60 62.8 103.4
Roof-Top Air Conditioning Units 5' 39 28 57.2 88.9
Trash Enclosure Activity 5' 60 30 57.3 89.0
Parking Lot Vehicle Movements 5' 60 60 52.6 81.1
Truck Movements 8' 60 60 59.8 93.2
Park Activities 5' 60' 0' 52.9 81.4
1 As measured by Urban Crossroads, Inc.
2 Anticipated duration (minutes within the hour) of noise activity during typical hourly conditions expected at the Project site. "Daytime" = 7:00 a.m. - 10:00 p.m.; "Nighttime" = 10:00 p.m. - 7:00 a.m. 3 Sound power level represents the total amount of acoustical energy (noise level) produced by a sound source independent of distance or surroundings. Sound power levels calculated using the CadnaA noise model at the reference distance to the noise source. Numbers may vary due to size differences between point and area noise sources.
10.2.2 LOADING DOCK ACTIVITY
Noise sources at loading docks located with the Light Industrial may include maneuvering and idling trucks, truck refrigeration units, forklifts, banging and clanging of equipment (i.e., hand carts and roll‐up doors), noise from public address systems, and voices of truck drivers and employees. The project proposes commercial uses, as described above that may contain loading docks. The reference loading dock activities are intended to describe the typical operational noise source levels associated with the Project. This includes truck idling, deliveries, backup alarms, unloading/loading, docking including a combination of tractor trailer semi-trucks, twoaxle delivery trucks, and background forklift operations.
At a uniform reference distance of 50 feet, Urban Crossroads collected a reference noise level of
62.8 dBA Leq. The loading dock activity noise level measurement was taken over a fifteen-minute period and represents multiple noise sources taken from the center of activity. The reference noise level measurement includes employees unloading a docked truck container included the squeaking of the truck’s shocks when weight was removed from the truck, employees playing music over a radio, as well as a forklift horn and backup alarm. In addition, during the noise level measurement a truck entered the loading dock area and proceeded to reverse and dock in a nearby loading bay, adding truck engine, idling, air brakes noise, in addition to on-going idling of an already docked truck. Loading dock activity is estimated during all the daytime, evening, and nighttime hours.
Noise generated by loading docks could exceed the City’s 65 dBA noise standard for residential and/or other sensitive noise receivers. Loading dock noise impacts are considered less than significant following compliance with the provisions of Ontario Municipal Code as specified in noise abatement measure 1.3.6, which would reduce noise impacts from loading docks to less than significant levels.
5973
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
52 10.2.3 ROOF-TOP AIR CONDITIONING UNITS
Mechanical equipment, such as generators, trash compactors, heating, ventilation and air conditioning (HVAC) units would be included as part of the proposed improvements. Mechanical equipment would be utilized in commercial as well as institutional areas. The noise level measurements describe a single mechanical roof-top air conditioning unit. The reference noise level represents a Lennox SCA120 series 10-ton model packaged air conditioning unit. At the uniform reference distance of 50 feet, the reference noise levels are 57.2 dBA Leq. Based on the typical operating conditions observed over a four-day measurement period, the roof-top air conditioning units are estimated to operate for and average 39 minutes per hour during the daytime hours, and 28 minutes per hour during the nighttime hours. These operating conditions reflect peak summer cooling requirements with measured temperatures approaching 96 degrees Fahrenheit (°F) with average daytime temperatures of 82°F. For this noise analysis, the air conditioning units are expected to be located on the roof of the Project buildings.
Noise generated from mechanical equipment could impact residential uses and other sensitive receivers within the project vicinity by exceeding the City’s 65 dBA noise standard. However, the proposed project would be subject to the provisions of Ontario Municipal Code, which requires that noise levels emitted from such equipment not exceed 65 dBA at any property line within a residential zone, residential use, or other noise‐sensitive use. Noise levels from mechanical equipment would be further minimized with implementation of mitigation requiring the orientation of equipment away from any sensitive receivers, proper selection of equipment, and installation of equipment with proper acoustical shielding; refer to noise abatement measure
1.2.5. With implementation of noise abatement measure 1.2.5 and compliance with Ontario Municipal Code provisions, potential impacts from mechanical equipment are considered less than significant.
10.2.5 TRASH ENCLOSURE ACTIVITY
To describe the noise levels associated with a trash enclosure activity, Urban Crossroads collected a reference noise level measurement at an existing trash enclosure containing two dumpster bins. The trash enclosure noise levels describe metal gates opening and closing, metal scraping against concrete floor sounds, dumpster movement on metal wheels, and trash dropping into the metal dumpster. The reference noise levels describe trash enclosure noise activities when trash is dropped into an empty metal dumpster, as would occur at the Project Site. The measured reference noise level at the uniform 50-foot reference distance is 57.3 dBA Leq for the trash enclosure activity. The reference noise level describes the expected noise source activities associated with the trash enclosures for the Project’s proposed building.
10.2.6 PARKING LOT ACTIVITY
The commercial and institutional uses proposed by the project would include designated parking areas. Traffic associated with parking lots is not of sufficient volume to exceed community noise standards that are based on a time averaged scale such as the CNEL scale. However, the instantaneous maximum sound levels generated by a car door slamming, an engine starting up, and car passing by may be an annoyance to adjacent sensitive receivers. Noise abatement 5974
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
53 measure 1.2.7 has been recommended requiring that subsequent noise analyses be prepared for future uses, as determined necessary by the City of Ontario, which demonstrate that all feasible sound attenuation has been incorporated into proposed parking areas (i.e., landscaping and brushed driving surfaces), so that noise from the parking areas has been minimized to the greatest extent practicable. Following mitigation, noise generated by parking lots is not expected to exceed the 65 dBA noise standard and a less than significant impact would occur in this regard.
Also, it should be noted that noise attenuation from existing walls and intervening vegetation and topography would further lessen potential impacts.
To describe the on-site parking lot activity, a long-term 29-hour reference noise level measurement was collected in the center of activity within the staff parking lot of an Amazon warehouse distribution center. At 50 feet from the center of activity, the parking lot produced a reference noise level of 52.6 dBA Leq. Parking activities are expected to take place during the full hour (60 minutes) throughout the daytime and evening hours. The parking lot noise levels are mainly due cars pulling in and out of parking spaces in combination with car doors opening and closing.
10.2.7 TRUCK MOVEMENTS
It is anticipated that truck deliveries would occur at the proposed commercial uses and industrial land uses. Noise generated by delivery trucks on the project site could exceed the City’s 65 dBA noise standard and a significant impact could occur unless mitigated. Delivery truck noise impacts would be minimized through compliance with the provisions of Ontario Municipal Code, as specified in noise abatement measure 1.2.6, which includes limitations on hours of operation when a commercial zone abuts a residential zone or residential use, would reduce noise impacts from trucks to less than significant levels.
The truck movements reference noise level measurement was collected over a period of 1 hour and 28 minutes and represents multiple heavy trucks entering and exiting the outdoor loading dock area producing a reference noise level of 59.8 dBA Leq at 50 feet. The noise sources included at this measurement location account for trucks entering and existing the Project driveways and maneuvering in and out of the outdoor loading dock activity area.
10.2.8 PARK ACTIVITIES
The project proposes parks that would include both active and passive uses. The parks would include picnic areas, basketball courts, tot lots, football, soccer, or softball facilities. Activities at the park could expose surrounding receivers to noise impacts from events at these facilities.
Since the residential land use would be located at a minimum of 50 feet from the proposed park facilities, noise generated from people utilizing the park would not exceed the City’s 65 dBA noise standard. Furthermore, potential park activities would be limited to operation during daytime hours. Impacts in this regard are considered less than significant.
To represent the potential noise level impacts associated with the Project’s Park activities, a reference noise level measurement was collected at the Founders Park in the unincorporated community of Ladera Ranch in the County of Orange. The reference noise levels collected at the 5975
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
54 Founders Park are expected to reflect the noise level activities within the open space-recreation land use areas of the Project site, since the reference noise level measurement includes girls’ youth soccer games, coaches shouting instructions, and parents speaking on cell phones at five feet from the noise level measurement location, and background noise levels from kids playing on swing sets and people cheering and clapping at 50 feet from the noise level measurement location. Using the uniform reference distance of 50 feet, the reference park activity noise level is 49.4 dBA Leq. The playground activities are estimated to occur for 60 minutes during the peak hour conditions.
10.3 CADNAANOISE PREDICTION MODEL
To fully describe the exterior operational noise levels from the Project, Urban Crossroads, Inc. developed a noise prediction model using the CadnaA (Computer Aided Noise Abatement) computer program. CadnaA can analyze multiple types of noise sources using the spatially accurate Project site plan, georeferenced Nearmap aerial imagery, topography, buildings, and barriers in its calculations to predict outdoor noise levels.
Using the ISO 9613-2 protocol, CadnaA will calculate the distance from each noise source to the noise receiver locations, using the ground absorption, distance, and barrier/building attenuation inputs to provide a summary of noise level at each receiver and the partial noise level contributions by noise source. Consistent with the ISO 9613-2 protocol, the CadnaA noise prediction model relies on the reference sound power level (Lw) to describe individual noise sources. While sound pressure levels (e.g., Leq) quantify in decibels the intensity of given sound sources at a reference distance, sound power levels (Lw) are connected to the sound source and are independent of distance. Sound pressure levels vary substantially with distance from the source and diminish because of intervening obstacles and barriers, air absorption, wind, and other factors. Sound power is the acoustical energy emitted by the sound source and is an absolute value that is not affected by the environment.
The operational noise level calculations provided in this noise study account for the distance attenuation provided due to geometric spreading, when sound from a localized stationary source (i.e., a point source) propagates uniformly outward in a spherical pattern. A default ground attenuation factor of 0.5 was used in the CadnaA noise analysis to account for mixed ground representing a combination of hard and soft surfaces. Appendix 10.1 includes the detailed noise model inputs used to estimate the Project operational noise levels presented in this section.
10.4 PROJECT OPERATIONAL NOISE LEVELS
Using the reference noise levels to represent the proposed Project operations that include loading dock activity, roof-top air conditioning units, trash enclosure activity, parking lot vehicle movements, truck movements and park activities, Urban Crossroads, Inc. calculated the operational source noise levels that are expected to be generated at the Project site and the Project-related noise level increases that would be experienced at each of the sensitive receiver locations. Table 10-2 shows the Project operational noise levels during the daytime hours of 7:00 5976
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
55 a.m. to 10:00 p.m. The daytime hourly noise levels at the off-site receiver locations are expected to range from 33.1 to 45.8 dBA Leq.
TABLE 10-2: DAYTIME PROJECT OPERATIONAL NOISE LEVELS
Noise Source1
Operational Noise Levels by Receiver Location (dBA Leq) R1 R2 R3 R4 R5 R6 R7 R8
Loading Dock Activity 44.6 44.4 40.6 41.7 39.3 38.6 34.1 32.3 Roof-Top Air Conditioning Units 29.2 30.0 42.0 32.6 36.1 30.3 28.7 21.9 Trash Enclosure Activity 24.1 24.5 37.5 27.2 20.4 21.3 17.8 16.0 Parking Lot Vehicle Movements 27.3 29.2 36.8 29.2 37.4 26.7 25.9 19.8 Truck Movements 27.2 28.6 27.8 30.1 30.4 23.3 20.9 17.6 Park Activities 24.6 22.6 26.1 23.5 28.5 28.8 31.5 20.5 Total (All Noise Sources) 44.9 44.8 45.8 42.8 42.9 39.6 35.9 33.1 1 See Exhibit 10-A for the noise source locations. CadnaA noise model calculations are included in Appendix 10.1.
Table 10-3 shows the Project operational noise levels during the nighttime hours of 10:00 p.m. to 7:00 a.m. The nighttime hourly noise levels at the off-site receiver locations are expected to range from 32.9 to 44.8 dBA Leq. The differences between the daytime and nighttime noise levels are largely related to the estimated duration of noise activity as outlined in Table 10-1 and Appendix 10.1.
TABLE 10-3: NIGHTTIME PROJECT OPERATIONAL NOISE LEVELS
Noise Source1
Operational Noise Levels by Receiver Location (dBA Leq) R1 R2 R3 R4 R5 R6 R7 R8
Loading Dock Activity 44.6 44.4 40.6 41.7 39.3 38.6 34.1 32.3 Roof-Top Air Conditioning Units 26.8 27.5 39.6 30.2 33.7 27.9 26.3 19.5 Trash Enclosure Activity 20.1 20.5 33.5 23.2 16.4 17.3 13.9 12.1 Parking Lot Vehicle Movements 27.3 29.2 36.8 29.2 37.4 26.7 25.9 19.8 Truck Movements 27.2 28.6 27.8 30.1 30.4 23.3 20.9 17.6 Park Activities 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Total (All Noise Sources) 44.8 44.7 44.5 42.5 42.4 39.3 35.5 32.9 1 See Exhibit 10-A for the noise source locations. CadnaA noise model calculations are included in Appendix 10.1.
10.5 PROJECT OPERATIONAL NOISE LEVEL COMPLIANCE
To demonstrate compliance with local noise regulations, the Project-only operational noise levels are evaluated against exterior noise level thresholds based on the City of Ontario exterior noise level standards at nearby noise-sensitive receiver locations. Table 10-4 shows the operational noise levels associated with Rich-Haven Specific Plan-2022 Amendment Project will satisfy the City of Ontario 70 dBA Leq daytime and 65 dBA Leq nighttime exterior noise level standards at the 5977
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
56 nearest receiver locations. Therefore, the operational noise impacts are considered less than significant at the nearby noise-sensitive receiver locations.
TABLE 10-4: OPERATIONAL NOISE LEVEL COMPLIANCE
Receiver
Location1
Project Operational
Noise Levels (dBA Leq)2
Noise Level Standards
(dBA Leq)3
Noise Level Standards
Exceeded?4
Daytime Nighttime Daytime Nighttime Daytime Nighttime
R1 44.9 44.8 65.0 45.0 No No
R2 44.8 44.7 65.0 45.0 No No
R3 45.8 44.5 65.0 45.0 No No
R4 42.8 42.5 65.0 45.0 No No
R5 42.9 42.4 65.0 45.0 No No
R6 39.6 39.3 65.0 45.0 No No
R7 35.9 35.5 65.0 45.0 No No
R8 33.1 32.9 65.0 45.0 No No
1 See Exhibit 9-A for the receiver locations.
2 Proposed Project operational noise level calculations are included in Appendix 10-1. 3 Section 5-29.04 of the City of Ontario Municipal Code (Appendix 3.1). 4 Do the estimated Project operational noise source activities exceed the noise level standards? "Daytime" = 7:00 a.m. to 10:00 p.m.; "Nighttime" = 10:00 p.m. to 7:00 a.m.
10.6 PROJECT OPERATIONAL NOISE LEVEL INCREASES
To describe the Project operational noise level increases, the Project operational noise levels are combined with the existing ambient noise levels measurements for the nearby receiver locations potentially impacted by Project operational noise sources. Since the units used to measure noise, decibels (dB), are logarithmic units, the Project-operational and existing ambient noise levels cannot be combined using standard arithmetic equations. (2) Instead, they must be logarithmically added using the following base equation:
SPLTotal = 10log10[10SPL1/10 + 10SPL2/10 + … 10SPLn/10] Where “SPL1,” “SPL2,” etc. are equal to the sound pressure levels being combined, or in this case, the Project-operational and existing ambient noise levels. The difference between the combined Project and ambient noise levels describes the Project noise level increases to the existing ambient noise environment. As indicated on Table 10-5, the Project will generate a daytime noise level increase ranging from 0.0 to 1.4 dBA Leq operational noise level increase at the nearest receiver locations. Table 10-6 shows that the Project will generate a nighttime operational noise level increase ranging from 0.0 to 1.6 dBA Leq at the nearest receiver locations.
The Project-related operational noise level increases will satisfy the operational noise level increase significance criteria presented on Table 4-1. Therefore, the incremental Project operational noise level increase is considered less than significant at all receiver locations. 5978
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
57 TABLE 10-5: DAYTIME PROJECT OPERATIONAL NOISE LEVEL INCREASES Receiver
Location1
Total Project
Operational
Noise Level2
Measurement
Location3
Reference
Ambient
Noise Levels4
Combined
Project
and
Ambient5
Project
Increase6
Increase
Criteria7
Increase
Criteria
Exceeded?
R1 44.9 L1 56.0 56.3 0.3 5.0 No
R2 44.8 L2 48.9 50.3 1.4 5.0 No
R3 45.8 L3 69.1 69.1 0.0 1.5 No
R4 42.8 L4 56.3 56.5 0.2 5.0 No
R5 42.9 L5 63.1 63.1 0.0 5.0 No
R6 39.6 L6 68.8 68.8 0.0 1.5 No
R7 35.9 L7 65.4 65.4 0.0 1.5 No
R8 33.1 L8 68.5 68.5 0.0 1.5 No
1 See Exhibit 9-A for the receiver locations.
2 Total Project daytime operational noise levels as shown on Table 10-2. 3 Reference noise level measurement locations as shown on Exhibit 5-A. 4 Observed daytime ambient noise levels as shown on Table 5-1. 5 Represents the combined ambient conditions plus the Project activities. 6 The noise level increase expected with the addition of the proposed Project activities. 7 Significance increase criteria as shown on Table 4-1.
TABLE 10-6: NIGHTTIME OPERATIONAL NOISE LEVEL INCREASES Receiver
Location1
Total Project
Operational
Noise Level2
Measurement
Location3
Reference
Ambient
Noise Levels4
Combined
Project
and
Ambient5
Project
Increase6
Increase
Criteria7
Increase
Criteria
Exceeded?
R1 44.9 L1 55.6 56.0 0.4 5.0 No
R2 44.8 L2 48.4 50.0 1.6 5.0 No
R3 45.8 L3 64.0 64.1 0.1 5.0 No
R4 42.8 L4 52.1 52.6 0.5 5.0 No
R5 42.9 L5 55.1 55.4 0.3 5.0 No
R6 39.6 L6 62.4 62.4 0.0 5.0 No
R7 35.9 L7 60.2 60.2 0.0 5.0 No
R8 33.1 L8 64.3 64.3 0.0 5.0 No
1 See Exhibit 9-A for the receiver locations.
2 Total Project nighttime operational noise levels as shown on Table 10-3. 3 Reference noise level measurement locations as shown on Exhibit 5-A. 4 Observed nighttime ambient noise levels as shown on Table 5-1. 5 Represents the combined ambient conditions plus the Project activities. 6 The noise level increase expected with the addition of the proposed Project activities. 7 Significance increase criteria as shown on Table 4-1. 5979
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
58 This page intentionally left blank
5980
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
59 11 CONSTRUCTION IMPACTS
This section analyzes potential impacts resulting from the short-term construction activities associated with the development of the Project. Exhibit 11-A shows the construction noise source locations in relation to the nearest sensitive receiver locations previously described in Section 9. The Project Conditions of Approval identified at Section 1.3, would minimize or eliminate a construction-source noise impacts. It is recommended that the City consider these noise abatement measures in their deliberations regarding the Project i While the City establishes limits to the hours during which construction activity may take place, it does not identify specific noise level limits for construction noise levels at potentially affected receiver locations for CEQA analysis purposes. In addition, since neither the City of Ontario General Plan or Municipal Code establish numeric maximum acceptable construction source noise levels at potentially affected receivers for CEQA analysis purposes, a numerical construction threshold based on Federal Transit Administration (FTA) Transit Noise and Vibration Impact Assessment Manual is used for analysis of daytime construction impacts. The FTA considers a daytime exterior construction noise level of 80 dBA Leq as a reasonable threshold for noise sensitive residential land use (8 p. 179).
11.1 CONSTRUCTION NOISE LEVELS
The FTA Transit Noise and Vibration Impact Assessment Manual recognizes that construction projects are accomplished in several different stages and outlines the procedures for assessing noise impacts during construction. Each stage has a specific equipment mix, depending on the work to be completed during that stage. As a result of the equipment mix, each stage has its own noise characteristics; some stages have higher continuous noise levels than others, and some have higher impact noise levels than others. The Project construction activities are expected to occur in the following stages:
• Site Preparation
• Grading
• Building Construction
• Paving
• Architectural Coating
11.2 CONSTRUCTION REFERENCE NOISE LEVELS
To describe construction noise activities, this construction noise analysis was prepared using reference construction equipment noise levels from the Federal Highway Administration (FHWA) published the Roadway Construction Noise Model (RCNM), which includes a national database of construction equipment reference noise emission levels. (24) The RCNM equipment database, provides a comprehensive list of the noise generating characteristics for specific types of construction equipment. In addition, the database provides an acoustical usage factor to estimate the fraction of time each piece of construction equipment is operating at full power (i.e., its loudest condition) during a construction operation. 5981
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
60 EXHIBIT 11-A: CONSTRUCTION NOISE SOURCE AND RECEIVER LOCATIONS 5982
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
61 11.3 CONSTRUCTION NOISE ANALYSIS
Using the reference construction equipment noise levels and the CadnaA noise prediction model, calculations of the Project construction noise level impacts at the nearby sensitive receiver locations were completed. Consistent with FTA guidance for general construction noise assessment, Table 11-1 presents the combined noise levels for the loudest construction equipment, assuming they operate at the same time. As shown on Table 11-2, the construction noise levels are expected to range from 46.5 to 63.8 dBA Leq at the nearby receiver locations.
Appendix 11.1 includes the detailed CadnaA construction noise model inputs.
TABLE 11-1: CONSTRUCTION REFERENCE NOISE LEVELS
Construction
Stage
Reference
Construction Activity
Reference Noise
Level @ 50 Feet
(dBA Leq)
1 Combined
Noise Level
(dBA Leq)
2 Combined Sound
Power Level
(PWL)3
Demolition
Demolition Equipment 82
Backhoes 74 83 115
Hauling Trucks 72
Site
Preparation
Crawler Tractors 78
Hauling Trucks 72 80 112
Rubber Tired Dozers 75
Grading
Graders 81
Excavators 77 83 115
Compactors 76
Building
Construction
Cranes 73
Tractors 80 81 113
Welders 70
Paving
Pavers 74
Paving Equipment 82 83 115
Rollers 73
Architectural
Coating
Cranes 73
Air Compressors 74 77 109
Generator Sets 70
1 FHWA Roadway Construction Noise Model (RCNM).
2 Represents the combined noise level for all equipment assuming they operate at the same time consistent with FTA Transit Noise and Vibration Impact Assessment guidance.
3 Sound power level represents the total amount of acoustical energy (noise level) produced by a sound source independent of distance or surroundings. Sound power levels calibrated using the CadnaA noise model at the reference distance to the noise source. 5983
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
62 TABLE 11-2: CONSTRUCTION EQUIPMENT NOISE LEVEL SUMMARY Receiver
Location1
Construction Noise Levels (dBA Leq)
Site
Preparation Grading BuildingConstruction Paving ArchitecturalCoating Highest
Levels2
R1 53.0 56.0 54.0 56.0 50.0 56.0
R2 50.3 53.3 51.3 53.3 47.3 53.3
R3 60.7 63.7 61.7 63.7 57.7 63.7
R4 52.8 55.8 53.8 55.8 49.8 55.8
R5 60.8 63.8 61.8 63.8 57.8 63.8
R6 52.1 55.1 53.1 55.1 49.1 55.1
R7 51.8 54.8 52.8 54.8 48.8 54.8
R8 49.5 52.5 50.5 52.5 46.5 52.5
1 Noise receiver locations are shown on Exhibit 11-A.
2 Construction noise level calculations based on distance from the construction activity, which is measured from the Project site boundary to the nearest receiver locations. CadnaA construction noise model inputs are included in Appendix 11.1.
11.4 CONSTRUCTION NOISE LEVEL COMPLIANCE
To evaluate whether the Project will generate potentially significant short-term noise levels at nearest receiver locations, a construction-related daytime noise level threshold of 80 dBA Leq is used as a reasonable threshold to assess the daytime construction noise level impacts. The construction noise analysis shows that the nearest receiver locations will satisfy the reasonable daytime 80 dBA Leq significance threshold during Project construction activities as shown on Table 11-3. With the implementation of mitigation measures N-1 and N-2, construction noise impacts would be less than significant.
TABLE 11-3: CONSTRUCTION NOISE LEVEL COMPLIANCE
Receiver
Location1
Construction Noise Levels (dBA Leq)
Highest Construction
Noise Levels2
Threshold3
Threshold
Exceeded?4
R1 56.0 80 No
R2 53.3 80 No
R3 63.7 80 No
R4 55.8 80 No
R5 63.8 80 No
R6 55.1 80 No
R7 54.8 80 No
R8 52.5 80 No
1 Noise receiver locations are shown on Exhibit 11-A.
2 Highest construction noise level calculations based on distance from the construction noise source activity to the nearest receiver locations as shown on Table 11-2.
3 Construction noise level thresholds as shown on Table 4-1. 4 Do the estimated Project construction noise levels exceed the construction noise level threshold? 5984
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
63 11.6 CONSTRUCTION VIBRATION ANALYSIS
Construction activity can result in varying degrees of ground vibration, depending on the equipment and methods employed. Operation of construction equipment causes ground vibrations that spread through the ground and diminish in strength with distance. Ground vibration levels associated with various types of construction equipment are summarized on Table 11-4. Based on the representative vibration levels presented for various construction equipment types, it is possible to estimate the potential for human response (annoyance) and building damage using the following vibration assessment methods defined by the FTA. To describe the vibration impacts the FTA provides the following equation: PPVequip = PPVref x (25/D)1.5
TABLE 11-4: VIBRATION SOURCE LEVELS FOR CONSTRUCTION EQUIPMENT Equipment PPV (in/sec)
at 25 feet
Small bulldozer 0.003
Jackhammer 0.035
Loaded Trucks 0.076
Large bulldozer 0.089
Vibratory Roller 0.210
Federal Transit Administration, Transit Noise and Vibration Impact Assessment Manual Table 11-5 presents the expected Project related vibration levels at the nearby receiver locations.
At distances ranging from 30 to 219 feet from Project construction activities, construction vibration velocity levels are estimated to range from 0.003 to 0.068 in/sec PPV. Based on maximum acceptable continuous vibration threshold of 0.3 PPV (in/sec), the typical Project construction vibration levels will fall below the building damage thresholds at all the noise sensitive receiver locations.
It is not anticipated that short-term construction operations or long-term operations for the proposed project would result in excessive groundborne vibration or ground borne noise levels.
Vibration producing construction equipment such as pile drivers is not typically used for the type of residential homes and commercial buildings that would be developed as part of the RichHaven Specific Plan. Although the proposed project would include the use of heavy-duty construction equipment, vibration impacts that would be generated would not damage structures within the project vicinity. In addition, long-term operation at residential units typically would not produce excessive ground vibration. Therefore, the Project-related vibration impacts are considered less than significant during typical construction activities at the Project site. 5985
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
64 TABLE 11-5: PROJECT CONSTRUCTION VIBRATION LEVELS
Receiver1
Distance
to
Const.
Activity
(Feet)2
Typical Construction Vibration Levels
PPV (in/sec)3 Thresholds
PPV
(in/sec)4
Thresholds
Exceeded?5
Small
bulldozer Jackhammer Loaded Trucks
Large
bulldozer
Highest
Vibration
Level
R1 76' 0.001 0.007 0.014 0.017 0.017 0.3 No
R2 219' 0.000 0.001 0.003 0.003 0.003 0.3 No
R3 30' 0.002 0.027 0.058 0.068 0.068 0.3 No
R4 94' 0.000 0.005 0.010 0.012 0.012 0.3 No
R5 30' 0.002 0.027 0.058 0.068 0.068 0.3 No
R6 150' 0.000 0.002 0.005 0.006 0.006 0.3 No
R7 156' 0.000 0.002 0.005 0.006 0.006 0.3 No
R8 189' 0.000 0.002 0.004 0.004 0.004 0.3 No
1 Receiver locations are shown on Exhibit 11-A.
2 Distance from receiver location to Project construction boundary (Project site boundary). 3 Based on the Vibration Source Levels of Construction Equipment (Table 11-4). 4 Caltrans Transportation and Construction Vibration Manual, April 2020 Table 19. 5 Does the peak vibration exceed the acceptable vibration thresholds? "PPV" = Peak Particle Velocity
5986
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
65 12 REFERENCES
1. State of California. California Environmental Quality Act, Environmental Checklist Form Appendix G. 2021.
2. California Department of Transportation Environmental Program. Technical Noise Supplement - A Technical Supplement to the Traffic Noise Analysis Protocol. Sacramento, CA : s.n., September 2013.
3. Environmental Protection Agency Office of Noise Abatement and Control. Information on Levels of Environmental Noise Requisite to Protect Public Health and Welfare with an Adequate Margin of Safety. March 1974. EPA/ONAC 550/9/74-004.
4. U.S. Department of Transportation, Federal Highway Administration, Office of Environment and Planning, Noise and Air Quality Branch. Highway Traffic Noise Analysis and Abatement Policy and Guidance. December 2011.
5. U.S. Department of Transportation Federal Highway Administration. Highway Noise Barrier Design Handbook. 2001.
6. U.S. Department of Transportation, Federal Highway Administration. Highway Traffic Noise in the United States, Problem and Response. April 2000. p. 3.
7. U.S. Environmental Protection Agency Office of Noise Abatement and Control. Noise Effects Handbook-A Desk Reference to Health and Welfare Effects of Noise. October 1979 (revised July 1981).
EPA 550/9/82/106.
8. U.S. Department of Transportation, Federal Transit Administration. Transit Noise and Vibration Impact Assessment Manual. September 2018.
9. Office of Planning and Research. State of California General Plan Guidlines. October 2019.
10. City of Ontario. Policy Plan Safety Element, S4, Noise Hazards. August 2022.
11. The City of Ontario. The Ontario Plan 2050 Final Supplemental Environmental Impact Report (FSEIR).
August 2022.
12. City of Ontario. Municipal Code, Chapter 29, Section 5- Noise.
13. California Department of Transportation. Transportation and Construction Vibration Guidance Manual. April 2020.
14. City of Ontario. Ontario International Airport Land Use Compatibility Plan. July 2018.
15. State of California. California Environmental Quality Act, Appendix G. 2018.
16. California Court of Appeal. Gray v. County of Madera, F053661. 167 Cal.App.4th 1099; - Cal.Rptr.3d, October 2008.
17. Federal Interagency Committee on Noise. Federal Agency Review of Selected Airport Noise Analysis Issues. August 1992.
18. California Department of Transportation. Technical Noise Supplement. November 2009.
19. American National Standards Institute (ANSI). Specification for Sound Level Meters ANSI S1.4- 2014/IEC 61672-1:2013.
20. U.S. Department of Transportation, Federal Highway Administration. FHWA Highway Traffic Noise Prediction Model. December 1978. FHWA-RD-77-108.
5987
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
66 21. California Department of Transportation Environmental Program, Office of Environmental Engineering. Use of California Vehicle Noise Reference Energy Mean Emission Levels (Calveno REMELs) in FHWA Highway Traffic Noise Prediction. September 1995. TAN 95-03.
22. California Department of Transportation. Traffic Noise Attenuation as a Function of Ground and Vegetation Final Report. June 1995. FHWA/CA/TL-95/23.
23. Urban Crossroads. Rich Haven Specific Plan. October 2022.
24. U.S. Department of Transportation, Federal Highway Administration, Office of Environment and Planning. FHWA Roadway Construction Noise Model. January, 2006. 5988
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
67 13 CERTIFICATIONS
The contents of this noise study report represent an accurate depiction of the noise environment and impacts associated with the proposed Rich-Haven Specific Plan-2022 Amendment Project.
The information contained in this noise study report is based on the best available data at the time of preparation. If you have any questions, please contact me directly at (949) 584-3148.
Bill Lawson, P.E., INCE
Principal
URBAN CROSSROADS, INC.
260 E. Baker Street, Suite 200
Costa Mesa, CA 92626
(949) 336-5979
[email protected]
EDUCATION
Master of Science in Civil and Environmental Engineering California Polytechnic State University, San Luis Obispo • December, 1993 Bachelor of Science in City and Regional Planning
California Polytechnic State University, San Luis Obispo • June, 1992
PROFESSIONAL REGISTRATIONS
PE – Registered Professional Traffic Engineer – TR 2537 • January, 2009 AICP – American Institute of Certified Planners – 013011 • June, 1997–January 1, 2012 PTP – Professional Transportation Planner • May, 2007 – May, 2013 INCE – Institute of Noise Control Engineering • March, 2004
PROFESSIONAL AFFILIATIONS
ASA – Acoustical Society of America
ITE – Institute of Transportation Engineers
PROFESSIONAL CERTIFICATIONS
Certified Acoustical Consultant – County of Orange • February, 2011 FHWA-NHI-142051 Highway Traffic Noise Certificate of Training • February, 2013 5989
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
68 This page intentionally left blank
5990
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
APPENDIX 3.1:
CITY OF ONTARIO DEVELOPMENT CODE
69 5991
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
70 5992
CHAPTER 29: NOISE
5-29.01 Declaration of findings and policy
5-29.02 Definitions
5-29.03 Designated noise zones
5-29.04 Exterior noise standards
5-29.05 Interior noise standards
5-29.06 Exemptions
5-29.07 Loud and disturbing noise
5-29.08 Real property maintenance noise regulations
5-29.09 Construction activity noise regulations
5-29.10 Other public agency exceptions
5-29.11 Schools, day care centers, churches, libraries, museums, health care institutions; Special provisions
5-29.12 Sound amplifying equipment
5-29.13 Amplified sound
5-29.14 Motor vehicles
5-29.15 Noise level measurement
5-29.16 Prima facie violation
5-29.17 Penalty
5-29.18 Enforcement and administration
5-29.19 City Manager waiver
5-29.20 Noise abatement program
Sec. 5-29.01. Declaration of findings and policy.
It is hereby found and declared that:
(a) The making and creation of excessive, unnecessary or unusually loud noises within the limits of the City is a condition that has existed for some time, however, the extent and volume of such noises is increasing; (b) The making, creation or maintenance of such excessive, unnecessary, unnatural or unusually loud noises that are prolonged, unusual and unnatural in their time, place and use affect and are a detriment to public health, comfort, convenience, safety, welfare and prosperity of the residents of the City; and (c) The necessity in the public interest for the provisions and prohibitions hereinafter contained and enacted, is declared as a matter of legislative determination and public policy, and it is further declared that the provisions and prohibitions hereinafter contained and enacted are in pursuance of and for the purpose of securing and promoting the public health, comfort, convenience, safety, welfare and prosperity and the peace and quiet of the residents of the City. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.02. Definitions.
As used in this chapter, specific words and phrases are defined as follows:
(a) "Ambient noise level" shall mean the all-encompassing noise level associated with a given environment and is a composite of sounds from all sources, excluding the alleged offensive noise or excessive sound, at the location and approximate time at which a comparison with the alleged offensive noise is to be made. (b) "Applicable (noise) zone" shall mean the noise zone category based on the actual use of the property, provided that the actual use is a legal use in the City.
(c) "A-weighted sound level" shall mean the sound pressure level in decibels (dBAs) as measured with a sound level meter using the A-weighted filter network (scale) at slow response and at a pressure of twenty (20) micropascals. The Aweighted filter de-emphasizes the very low and a very high frequency component of sound in a manner similar to the response of the human ear, and is a numerical method of rating human judgment of loudness. (d) "Decibel (dBA)" shall mean a unit for measuring the amplitude of a sound, equal to twenty (20) times the logarithm to the base ten (10) of the ratio of pressure of the sound measured to the reference pressure of twenty (20) micropascals. 71 5993
(e) "Equivalent sound or noise level (Leq)" shall mean the International Electrotechnical Commission (IEC) 60804 Standard for measurement, or the most recent revision thereof, for the sound level corresponding to a steady state noise level over a given sample period with the same amount of acoustic energy as the actual time varying noise level or the energy average noise level during the sample period. The measurement period for the purposes of this chapter is fifteen (15) minutes.
(f) "Impulsive noise" shall mean a noise of short duration usually less than one (1) second and of high intensity, with an abrupt onset and rapid decay. Such objectionable noises may also be repetitive. (g) "Intrusive noise" shall mean that noise that intrudes over and above the ambient noise at a given location. The relative intrusiveness of a sound depends upon its amplitude, duration, frequency, time of occurrence and tonal information content, as well as the prevailing ambient noise level. (h) "Maintenance" shall mean the upkeep, repair or preservation of existing property or structures. (i) "Noise" shall mean any unwanted sound or sound that is undesirable because it interferes with speech and hearing, or is intense enough to damage hearing or is otherwise annoying. (j) "Noise level (sound level)" shall mean the weighted sound pressure level obtained by use of a sound level meter having a standard frequency filter for attenuating part of the sound spectrum. For purposes of this chapter, all noise levels (sound levels) shall be A-weighted sound pressure level. (k) "Noise (sound) level meter" shall mean an instrument, including a microphone, an amplifier, an output meter and frequency weighting networks for the measurement and determination of noise and sound levels. For the purposes of this chapter, the sound level meter must meet the International Electrotechnical Commission (IEC) 60651 and 60804 Standards, or the most recent revisions thereof, for Type 1 sound level meters or an instrument and the associated recording and analyzing equipment that will provide equivalent data.
(§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.03. Designated noise zones.
The properties hereinafter described shall be assigned to the following noise zones:
Noise Zone I: All single-family residential properties; Noise Zone II: All multi-family residential properties and mobile home parks;
Noise Zone III: All commercial property;
Noise Zone IV: The residential portion of mixed use properties; Noise Zone V: All manufacturing or industrial properties and all other uses.
The actual use of the property, and not necessarily its zoning designation, shall be the determining factor in establishing whether a property is in Noise Zone I, II, III, IV or V, provided that the actual use is a legal use within the applicable zone. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.04. Exterior noise standards.
(a) The following exterior noise standards, unless otherwise specifically indicated, shall apply to all properties within a designated noise zone.
Allowable Exterior Noise Level (1) Allowed Equivalent Noise Level, Leq. (2)
Noise
Zone Type of Land Use 7 a.m. to 10 p.m. 10 p.m. to 7 a.m.
I Single-Family Residential 65 dBA 45 dBA
II Multi-Family Residential, Mobile
Home Parks 65 dBA 50 dBA
III Commercial Property 65 dBA 60 dBA
IV Residential Portion of Mixed Use 70 dBA 70 dBA
V Manufacturing and Industrial, Other
Uses 70 dBA 70 dBA
(1) If the ambient noise level exceeds the resulting standard, the ambient noise level shall be the standard. 72 5994
(2) Measurements for compliance are made on the affected property pursuant to § 5-29.15. (b) It is unlawful for any person at any location within the incorporated area of the City to create noise, or to allow the creation of any noise on property owned, leased, occupied or otherwise controlled by such person, which noise causes the noise level, when measured at any location on any other property, to exceed either of the following:
(1) The noise standard for the applicable zone for any fifteen-minute (15) period; and (2) A maximum instantaneous (single instance) noise level equal to the value of the noise standard plus twenty (20) dBA for any period of time (measured using A-weighted slow response). (c) In the event the ambient noise level exceeds the noise standard, the maximum allowable noise level under such category shall be increased to reflect the maximum ambient noise level. (d) The Noise Zone IV standard shall apply to that portion of residential property falling within one hundred (100) feet of a commercial property or use, if the noise originates from that commercial property or use. (e) If the measurement location is on a boundary between two (2) different noise zones, the lower noise level standard applicable to the noise zone shall apply.
(§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.05. Interior noise standards.
(a) The following interior noise standards, unless otherwise specifically indicated, shall apply to all properties within a designated noise zone.
Allowable Interior Noise Level (1) Allowed Equivalent Noise Level, Leq. (2) Noise Zone Type of Land Use 7 a.m. to 10 p.m. 10 p.m. to 7 a.m.
I Single-Family Residential 45 dBA 40 dBA
II Multi-Family Residential, Mobile
Home Parks 45 dBA 40 dBA
IV Residential Portion of Mixed Use 45 dBA 40 dBA
(1) If the ambient noise level exceeds the resulting standard, the ambient noise level shall be the standard. (2) Measurements for compliance are made on the affected property pursuant to § 5-29.15. (b) It is unlawful for any person at any location within the incorporated area of the City to create noise, or to allow the creation of any noise on property owned, leased, occupied or otherwise controlled by such person, which noise causes the noise level, when measured at any location on any other property, to exceed either of the following:
(1) The noise standard for the applicable zone for any fifteen-minute (15) period; (2) A maximum instantaneous (single instance) noise level equal to the value of the noise standard plus twenty (20) dBA for any period of time (measured using A-weighted slow response). (c) In the event the ambient noise level exceeds the noise standard, the maximum allowable noise level under such category shall be increased to reflect the maximum ambient noise level. (d) The Noise Zone IV standard shall apply to that portion of residential property falling within one hundred (100) feet of a commercial property or use, if the noise originates from that commercial property or use. (e) If the measurement location is on a boundary between two (2) different noise zones, the lower noise level standard applicable to the noise zone shall apply.
(§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.06. Exemptions.
The following activities shall be exempted from the provisions of this chapter:
(a) Any activity conducted on public property, or on private property with the consent of the owner, by any public entity or its officers, employees, representatives, agents, subcontractors, permittees, licensees or lessees that the public entity has authorized are exempt from the provisions of this chapter. This includes, without limitation, sporting and recreational activities that are sponsored, co-sponsored, permitted or allowed by the City or any school district within the City's jurisdictional boundaries. This also includes, without limitation, occasional outdoor gatherings, public dances, shows or sporting and entertainment events, provided such events are conducted pursuant to an approval, authorization, contract, lease, permit or sublease by the appropriate public entity, specifically the planning commission or City Council; (b) Occasional outdoor gatherings, public dances, show, sporting and entertainment events, provided said events are 73 5995
conducted pursuant to a permit or license issued by the appropriate jurisdiction relative to the staging of said events; (c) Any mechanical device, apparatus or equipment used, related to or connected with emergency machinery, vehicle, work or warning alarm or bell, provided the sounding of any bell or alarm on any building or motor vehicle shall terminate its operation within forty-five (45) minutes in any hour of its being activated; (d) Noise sources associated with construction, repair, remodeling, demolition or grading of any real property. Such activities shall instead be subject to the provisions of § 5-29.09; (e) Noise sources associated with construction, repair, remodeling, demolition or grading of public rights-of-way or during authorized seismic surveys;
(f) All mechanical devices, apparatus or equipment associated with agriculture operations provided that:
(1) Operations do not take place between 8:00 p.m. and 7:00 a.m.; (2) Such operations and equipment are utilized for the protection or salvage of agricultural crops during periods of potential or actual frost damage or other adverse weather conditions; or (3) Such operations and equipment are associated with agricultural pest control through pesticide application, provided the application is made in accordance with permits issued by or regulations enforced by the California Department of Agriculture;
(g) Noise sources associated with the maintenance of real property. Such activities shall instead be subject to the provisions of § 5-29.08;
(h) Any activity to the extent regulation thereof has been preempted by state or federal law; (i) Any noise sources associated with people and/or music associated with a party at a residential property. Such noise shall be subject to the provisions of OMC § 5-29.07;
(j) Any noise source emanating from an ice cream truck within the City. Such noise shall be subject to the provisions of OMC § 4-18.04;
(k) Any noise sources associated with barking dogs or other intermittent noises made by animals on any properly within the City. Such noise shall be subject to the provisions of OMC Chapter 1, Title 6; (l) Noise sources related to uses approved by a permit or development agreement adopted prior to the date of adoption of this chapter and that contains acoustic or noise standard conditions of approval. This exemption shall only be applicable during the effective period of the City-approved permit or development agreement. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.07. Loud and disturbing noise.
(a) It is unlawful for any person or property owner within the City to make, cause or allow to be made any loud, excessive, impulsive or intrusive noise, disturbance or commotion that disturbs the peace or quiet of any area or that causes discomfort or annoyance to any reasonable person of normal sensitivities in the area, after a Police or Code Enforcement Officer has first requested that the person or property owner cease and desist from making such noise. The types of loud, disturbing, excessive, impulsive or intrusive noise may include, but shall not be limited to, yelling, shouting, hooting, whistling, singing, playing a musical instrument, or emitting or transmitting any loud music or noise from any mechanical or electrical sound making or sound-amplifying device.
(b) The factors, standards, and conditions that may be considered in determining whether a violation of the provisions of this section has been committed, included, but not limited to, the following:
(1) The level of the noise;
(2) The level and intensity of the background (ambient) noise, if any; (3) The proximity of the noise to residential or commercial sleeping areas; (4) The nature and zoning of the area within which the noise emanates; (5) The density of inhabitation of the area within which the noise emanates; (6) The time of day and night the noise occurs;
(7) The duration of the noise;
(8) Whether the noise is constant, recurrent or intermittent; (9) Whether the noise is produced by a commercial or noncommercial activity; and (10) Whether the use is lawful under the provisions of Title 5 of this Code and whether the noise is one that could reasonably be expected from the activity or allowed use. (§ 2, Ord. 2888, eff. March 6, 2008)
74 5996
Sec. 5-29.08. Real property maintenance noise regulations. (a) No person, while engaged in maintenance of real property, shall operate any tool, equipment or machine in a manner that produces loud noise that disturbs a person of normal sensitivity who works or resides in the vicinity, or a Police or Code Enforcement Officer, except between the hours of 8:00 a.m. and 6:00 p.m. (b) Trimming or pruning that requires the use of chainsaws or mulching machines shall only be allowed between the hours of 8:00 a.m. and 6:00 p.m. on a weekday and between the hours of 9:00 a.m. and 5:00 p.m. on Saturday or Sunday. (c) The use of electrical or gasoline powered blowers, such as commonly used by gardeners or other persons for cleaning lawns, yards, driveways, gutters and other property shall only be allowed between the hours of 8:00 a.m. and 6:00 p.m. on a weekday and between the hours of 9:00 a.m. and 5:00 p.m. on Saturday or Sunday. (d) No landowner, gardener, property maintenance service, contractor, subcontractor or employer shall permit or allow any person or persons working under his or her direction or control to operate any tool, equipment or machine in violation of the provisions of this section.
(e) Exceptions. The provisions of this section shall not apply to the following:
(1) Emergency property maintenance required by the building official; (2) The maintenance, repair or improvement of any public work or facility by public employees, by any person or persons acting pursuant to a public works contract, or by any person or persons performing such work or pursuant to the direction of, or on behalf of, any public agency; provided, however, this exception shall not apply to the City, or its employees, contractors or agents, unless:
(i) The City Manager or department head determines that the maintenance, repair or improvement is immediately necessary to maintain public service,
(ii) The maintenance, repair or improvement is of a nature that cannot feasibly be conducted during normal business hours, or
(iii) The City Council has approved project specifications, contract provisions, or an environmental document that specifically authorizes maintenance during hours of the day that would otherwise be prohibited pursuant to this section; and (3) Any maintenance that complies with the noise limits specified in § 5-29.04. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.09. Construction activity noise regulations.
(a) No person, while engaged in construction, remodeling, digging, grading, demolition or any other related building activity, shall operate any tool, equipment or machine in a manner that produces loud noise that disturbs a person of normal sensitivity who works or resides in the vicinity, or a Police or Code Enforcement Officer, on any weekday except between the hours of 7:00 a.m. and 6:00 p.m. or on Saturday or Sunday between the hours of 9:00 a.m. and 6:00 p.m. (b) No landowner, construction company owner, contractor, subcontractor, or employer shall permit or allow any person or persons working under their direction and control to operate any tool, equipment or machine in violation of the provisions of this section.
(c) Exceptions.
(1) The provisions of this section shall not apply to emergency construction work performed by a private party when authorized by the City Manager or his or her designee;
(2) The maintenance, repair or improvement of any public work or facility by public employees, by any person or persons acting pursuant to a public works contract, or by any person or persons performing such work or pursuant to the direction of, or on behalf of, any public agency; provided, however, this exception shall not apply to the City, or its employees, contractors or agents, unless:
(i) The City Manager or a department head determines that the maintenance, repair or improvement is immediately necessary to maintain public services,
(ii) The maintenance, repair or improvement is of a nature that cannot feasibly be conducted during normal business hours, or
(iii) The City Council has approved project specifications, contract provisions, or an environmental document that specifically authorizes construction during hours of the day that would otherwise be prohibited pursuant to this section; and (3) Any construction that complies with the noise limits specified in §§ 5-29.04 or 5-29.05. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.10. Other public agency exceptions.
The provisions of this chapter shall not be construed to prohibit any work at different hours by or under the direction of any other public agency or public or private utility companies in cases of necessity or emergency. 75 5997
(§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.11. Schools, day care centers, churches, libraries, museums, health care institutions; Special provisions.
It is unlawful for any person to create any noise that causes the outdoor noise level at any school, day care center, hospital or similar health care institution, church, library or museum while the same is in use, to exceed the noise standards specified in § 5-29.04 prescribed for the assigned Noise Zone I. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.12. Sound amplifying equipment.
Loudspeakers, sound amplifiers, public address systems or similar devices used to amplify sounds shall be subject to the provisions of § 5-29.13. Such sound amplifying equipment shall not be construed to include electronic devices, including but not limited to, radios, tape players, tape recorders, compact disc players, MP3 players, electric keyboards, music synthesizers, record players or televisions, which are designed and operated for personal use, or used entirely within a building and are not designed or used to convey the human voice, music or any other sound to an audience outside such building, or which are used in vehicles and heard only by occupants of the vehicle in which installed. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.13. Amplified sound.
(a) The City Council enacts the following legislation for the sole purpose of securing and promoting the public health, comfort, safety and welfare for its citizenry. While recognizing that the use of sound amplifying equipment may be entitled to certain protection by the constitutional rights of freedom of speech and assembly, the City Council finds that in order to protect the public safety and the correlative rights of the citizens of this community to privacy and freedom from public nuisance of loud and unnecessary noise, reasonable regulation of the time, place and manner of the use of amplifying equipment is necessary. In no event shall approval or authorization required herein be withheld by reason of the constitutionally protected content of any material proposed to be broadcast through amplifying equipment. (b) It is unlawful for any person, other than personnel of law enforcement or governmental agencies, to install, use or operate a loudspeaker or sound amplifying device in a fixed or movable position or mounted upon any vehicle within the City for the purpose of giving instructions, directions, talks, addresses or lectures to any persons or assemblages of persons in or upon any street, alley, sidewalk, park, place or public property without a permit to do so from the Police Chief or his or her designee. Notwithstanding any other provision of this chapter, the provisions of this section shall also apply to the use of sound amplifying equipment upon public or private property when used in connection with outdoor or indoor public or private events, whether or not admission is charged or food or beverages are sold, when such activity is to be attended by more than one hundred (100) persons and the noise emanating from the event will be audible at the property plane, or in the case of a street dance or concert on the nearest residential property. Those activities listed in § 5-29.06(a) are exempt from the requirements of this section.
(c) The Police Chief or his or her designee is authorized to approve and issue permits under this section. (d) An application for a permit required by this section shall be filed with the Police Chief at least sixteen (16) days and no more than one hundred twenty (120) days prior to the date on which the sound amplifying equipment is intended to be used. Applications for events covered by the First Amendment of the United States Constitution are exempt from the time requirements of this section if it is shown that circumstances require a shorter filing period and the event will not constitute an unsafe condition. The application shall contain the following information:
(1) The name, address and telephone number of both the owner and the user of the sound amplifying equipment; (2) The license number, if a sound truck is to be used; (3) A general description of the sound amplifying equipment which is to be used; (4) Whether sound amplifying equipment will be used for commercial or noncommercial purpose; (5) The dates and times upon and within which, and the streets or property over or upon which, the equipment is proposed to be operated;
(6) The name or names of one (1) or more persons who will be present during the conduct of any activities for which registration is sought and who will have authority to reduce the volume of any sound amplifying equipment during the course of the activities if required pursuant to this chapter and, otherwise, to insure compliance with the provisions of this chapter; (7) A statement by the applicant that he or she is willing and able to comply with the provisions of this chapter and the conditions of the permit; and
(8) A sketch of the area or facilities within which the activities are to be conducted, with approximate dimensions and illustration of the location and orientation of all sound-amplifying equipment. (e) The Police Chief shall deny the permit application or revoke any permit if the chief finds any of the following:
(1) The application contains materially false or intentionally misleading information; (2) The use of sound amplifying equipment at an event or activity proposed will be located in or upon a premises, 76 5998
building or structure that is hazardous to the health or safety of the employees or patrons of the premises, business, activity, or event, or the general public, under the standards established by the Uniform Building or Fire Codes, or other applicable codes, as set forth in OMC Titles 4 and 8;
(3) The use of sound amplifying equipment at an event or activity proposed in or upon a premises, building or structure that lacks adequate on-site parking for participants attending the proposed event or activity under the applicable standards set forth in OMC Title 9;
(4) The conditions of any motor vehicle movement are such that, in his or her opinion, the use of the equipment would constitute an unreasonable interference with traffic safety; (5) The conditions of pedestrian movement are such that the use of the equipment would constitute a detriment to traffic safety;
(6) The application submitted by the applicant reveals that the applicant would violate the provisions of this section or any other provision of federal, state and/or local law; (7) The applicant is unwilling or unable to comply with the provisions of this chapter or any conditions imposed upon any permit issued;
(8) There had already been a permitted event at the intended location, or within a two hundred (200) yard radius of the intended location and the prior permitted event was located on residentially zoned property or on a street, alley, public parking lot or neighborhood park within three (3) months prior to the intended event. Community parks are exempt from this subsection (8); or
(9) The applicant or location has had previous violations within the past calendar year, and in the judgment of the Police Chief, issuance would be contrary to the intent of this section. (f) In determining whether the use of the equipment would constitute an unreasonable interference with or detriment to traffic safety, the Police Chief shall consider, but shall not necessarily be limited to:
(1) The volumes, patterns and speed of vehicular and pedestrian traffic in the proposed area of use; (2) The relationship of the proposed use of equipment and potential impacts upon traffic patterns; (3) Availability of sufficient room for the operation of the equipment without significantly interfering with the traffic patterns;
(4) Proximity to schools, playgrounds and similar facilities where use of such equipment might attract children into traffic patterns; or
(5) Proximity to busy intersections or other potentially hazardous conditions where use of such equipment might constitute a hazard by reason of its tendency to distract drivers of vehicles or pedestrians. (g) Issuance or denial.
(1) If the application is approved, the Police Chief shall return an approved copy of the application to the applicant and shall issue a permit. The permit shall constitute permission for the use of the sound amplifying equipment as requested. (2) Any application filed shall be either approved or disapproved within five (5) days of the filing thereof. (3) If the application is disapproved, the Police Chief shall return a disapproved copy forthwith to the applicant with a written statement on the reason for disapproval.
(i) Any person aggrieved by a decision of the Police Chief or his or her designee may file an appeal to the City Manager. A complete and proper appeal shall be filed with the City Clerk within ten (10) calendar days of the action that is the subject of the appeal. If the applicant fails to file an appeal within the ten (10) day filing period provided herein, denial shall take effect immediately upon expiration of such filing period. All appeals shall be in writing and shall contain the following information: (a) name(s) of the person filing the appeal, (b) a brief statement in ordinary and concise language of the relief sought, and (c) the signatures of all parties named as appellants and their mailing addresses. After receiving the appeal, the City Clerk shall immediately forward the matter to the City Manager for handling. (ii) The City Manager shall, upon receipt of the appeal, set the matter for hearing before the City Manager or a hearing officer. Any hearing officer shall be a licensed attorney or recognized mediator designated by the City Manager.
The hearing shall be set for not more than ten (10) calendar days after the receipt of the appeal unless a longer time is requested or consented to by the appellant. Notice of such hearing shall be given in writing and mailed at least five (5) calendar days prior to the date of the hearing, by U.S. mail, with a proof of service attached, addressed to the address listed on the permit application, or the written appeal if different from the permit application. The notice shall state the grounds of the complaint or reason for the denial and shall state the time and place where such hearing will be held. (iii) The City Manager or hearing officer shall, within ten (10) calendar days following the conclusion of the hearing, make a written finding and decision, which shall be delivered to the City and the appellant by first class mail.
Notwithstanding any provision in this Code, the decision of the City Manager or hearing officer shall be the final administrative decision of the City. Any party dissatisfied with the decision of the City Manager or hearing officer may seek review of such decision under the provisions of Code Civil Procedure, §§ 1094.5 and 1094.8, as amended from time to time. 77 5999
(h) In addition to any other provisions of this Code, the use of sound-amplifying equipment and sound trucks in the City shall be subject to the following regulations:
(1) The only sounds permitted are music and human speech; (2) Sound shall not be emitted within one hundred (100) yards of hospitals, churches, schools and City Hall; (3) The volume of sound shall be controlled so that it will not be audible for a distance in excess of one hundred (100) feet from the sound amplifying equipment or sound truck, and so that the volume is not unreasonably loud, raucous, jarring, disturbing or a nuisance to persons within the range of allowed audibility; or (4) The sound amplifying equipment or sound truck shall not be used between the hours of 8:00 p.m. and 8:00 a.m. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.14. Motor vehicles.
The use of any motor vehicle in such a condition as to create excessive, impulsive or intrusive noises is prohibited. The discharge into the open air of the exhaust of any internal combustion engine, stationary or mounted on wheels, motorboat or motor vehicle, including motor cycle, whether or not discharged through a muffler or other similar device, which discharge creates excessive, unusual, impulsive or intrusive noise is prohibited. Motor vehicles shall comply with the noise regulations of the California Vehicle Code.
(§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.15. Noise level measurement.
(a) The location selected for measuring exterior noise levels in a residential area shall be at any part of a private yard, patio, deck or balcony normally used for human activity and identified by the owner or, if occupied by someone other than the owner, the occupant of the affected property as suspected of exceeding the noise level standard. This location may be the closest point in the private yard or patio, or on the deck or balcony, to the noise source, but should not be located in nonhuman activity areas such as trash container storage areas, planter beds, above or contacting a property line fence, or other areas not normally used as part of the yard, patio, deck or balcony. The location selected for measuring exterior noise levels in a nonresidential area shall be at the closest point to the noise source. The measurement microphone height shall be five (5) feet above finish elevation or, in the case of a deck or balcony, the measurement microphone height shall be five (5) feet above the finished floor level.
(b) The location selected for measuring interior noise levels shall be made within the affected residential unit. The measurements shall be made at a point at least four (4) feet from the wall, ceiling or floor, or within the frame of a window opening, nearest the noise source. The measurements shall be made with windows in an open position. (c) Any decibel measurement made pursuant to the provisions of this chapter shall be measured in decibels (dBAs) as measured with a sound level meter using the A-weighted sound pressure level. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.16. Prima facie violation.
Any noise exceeding the noise level standard as specified in §§ 5-29.04 and 5-29.05, shall be deemed to be prima facie evidence of a violation of the provisions of this chapter. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.17. Penalty.
(a) Any person who negligently or knowingly violates any provision of this chapter shall be guilty of an infraction and upon conviction shall be punishable by a fine specified in OMC § 1-2.01. Each day a violation occurs shall constitute a separate offense and shall be punishable as such.
(b) Any person who negligently or knowingly violates any provision of this chapter may also be subject to fine(s) specified in the administrative citation schedule of fines set forth in OMC § 1-5.04. The manner of issuing administrative citations shall comply with all the procedures specified in OMC Chapter 5, Title 1. (c) As an additional remedy, the operation or maintenance of any device, instrument, vehicle or machinery in violation of any provisions of this chapter, which operation or maintenance causes or creates sound levels exceeding the allowable standards as specified in this chapter, shall be deemed and is declared to be a public nuisance and may be subject to abatement by a restraining order or injunction issued by a court of competent jurisdiction. (d) Any violation of this chapter is declared to be a public nuisance and may be abated in accordance with law. The expense of enforcing this chapter is declared to be public nuisance and may be by resolution of the City Council declared to be a lien and special assessment against the property on which such nuisance is maintained, and any such charge shall also be a personal obligation of the property owner.
(§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.18. Enforcement and administration.
78 6000
(a) It shall be the responsibility of Police or Code Enforcement Officers to enforce the provisions of this chapter and to perform all other functions required by this chapter. Such duties shall include, but not be limited to investigating potential violations, issuing warning notices and citations, and providing evidence to the City prosecutor for legal action. (b) For violations of § 5-29.07, Police or Code Enforcement Officers shall obtain a declaration under penalty of perjury from two (2) declarants living in separate households within a sixty (60) day period stating in detail all of the following:
(1) That the declarant is a resident of a residential neighborhood located within two hundred (200) yards of the noise source; and
(2) Within the past month declarant has heard noise for substantially long periods to the extreme annoyance of the declarant.
(3) Declarations from two (2) declarants are required to prove a violation of § 5-29.07, but are not required to prove that a person has violated any other provision of this chapter. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.19. City Manager waiver.
The City Manager is authorized to grant a temporary waiver to the provisions of this chapter for a period of time necessary to correct the violations of this chapter, if such temporary waiver would be in the public interest and there is no feasible and prudent alternative to the activity, or the method of conducting the activity, for which the temporary waiver is sought. This time period may include a commitment to a program that includes placing necessary orders and entering into necessary contracts within thirty (30) days for repair or installation. (§ 2, Ord. 2888, eff. March 6, 2008)
Sec. 5-29.20. Noise abatement program.
(a) In circumstances where adopted community-wide noise standards and policies prove impractical in controlling noise generated from a specific source, the City Council may establish a noise abatement program that recognizes the characteristics of the noise source and affected property and that incorporates specialized mitigation measures. (b) Noise abatement programs shall set forth in detail the approved terms, conditions and requirements for achieving maximum compliance with noise standards and policies. Said terms, conditions and requirements may include, but shall not be limited to, limitations, restrictions, or prohibitions on operating hours, location of operations, and the types of equipment. (§ 2, Ord. 2888, eff. March 6, 2008)
79 6001
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
80 6002
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
APPENDIX 5.1:
STUDY AREA PHOTOS
81 6003
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
82 6004
JN:14822
14822_L1_A 1.North
34, 0' 52.160000"117, 34' 1.810000"
14822_L1_A 2.South
34, 0' 52.010000"117, 34' 1.700000"
14822_L1_A 3.East
34, 0' 52.050000"117, 34' 1.700000"
14822_L1_A 4.West
34, 0' 51.970000"117, 34' 1.780000"
83 6005
JN:14822
14822_L2_E 1.North
34, 0' 47.870000"117, 33' 58.180000"
14822_L2_E 2.South
34, 0' 47.900000"117, 33' 58.160000"
14822_L2_E 3.East
34, 0' 47.930000"117, 33' 58.160000"
14822_L2_E 4.West
34, 0' 47.940000"117, 33' 58.160000"
84 6006
JN:14822
14822_L3_H 1.North
34, 0' 3.560000"117, 33' 58.930000"
14822_L3_H 2.South
34, 0' 3.560000"117, 33' 58.900000"
14822_L3_H 3.East
34, 0' 3.560000"117, 33' 58.930000"
14822_L3_H 4.West
34, 0' 3.520000"117, 33' 58.930000"
85 6007
JN:14822
14822_L4_I 1.North
33, 59' 49.970000"117, 34' 8.100000"
14822_L4_I 2.South
33, 59' 49.990000"117, 34' 8.100000"
14822_L4_I 3.East
33, 59' 49.990000"117, 34' 7.910000"
14822_L4_I 4.West
33, 59' 49.970000"117, 34' 7.990000"
86 6008
JN:14822
14822_L5_G 1.North
34, 0' 6.940000"117, 34' 15.620000"
14822_L5_G 2.South
34, 0' 6.850000"117, 34' 15.620000"
14822_L5_G 3.East
34, 0' 6.830000"117, 34' 15.600000"
14822_L5_G 4.West
34, 0' 6.800000"117, 34' 15.680000"
87 6009
JN:14822
14822_L6_S 1.North
34, 0' 14.360000"117, 34' 32.710000"
14822_L6_S 2.South
34, 0' 14.250000"117, 34' 32.650000"
14822_L6_S 3.East
34, 0' 14.250000"117, 34' 32.630000"
14822_L6_S 4.West
34, 0' 14.240000"117, 34' 32.710000"
88 6010
JN:14822
14822_L7_X 1.North
34, 0' 42.380000"117, 34' 33.750000"
14822_L7_X 2.South
34, 0' 42.340000"117, 34' 33.750000"
14822_L7_X 3.East
34, 0' 42.370000"117, 34' 33.640000"
14822_L7_X 4.West
34, 0' 42.410000"117, 34' 33.670000"
89 6011
JN:14822
14822_L8_Z 1.North
34, 1' 8.990000"117, 34' 31.010000"
14822_L8_Z 2.South
34, 1' 8.970000"117, 34' 31.010000"
14822_L8_Z 3.East
34, 1' 8.970000"117, 34' 31.010000"
14822_L8_Z 4.West
34, 1' 8.910000"117, 34' 31.090000"
90 6012
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
APPENDIX 5.2:
NOISE LEVEL MEASUREMENT WORKSHEETS
91 6013
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
92 6014
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 57.3 61.7 55.8 61.5 61.2 60.0 59.1 57.2 56.7 56.2 56.0 55.9 57.3 10.0 67.3 1 56.5 59.5 55.2 59.3 59.1 58.5 57.8 56.7 56.1 55.6 55.5 55.3 56.5 10.0 66.5 2 56.4 66.5 46.9 65.0 63.7 62.4 61.4 58.3 49.0 47.5 47.3 47.1 56.4 10.0 66.4 3 51.6 55.9 49.9 55.7 55.3 54.5 53.4 51.7 51.0 50.4 50.2 50.0 51.6 10.0 61.6 4 47.3 55.9 37.4 55.5 55.0 53.7 52.3 48.3 43.0 38.0 37.8 37.5 47.3 10.0 57.3 5 55.2 67.3 38.7 66.8 66.0 62.6 59.8 54.0 46.1 39.6 39.2 38.8 55.2 10.0 65.2 6 58.8 64.6 55.6 64.4 64.1 63.2 62.5 59.1 57.1 56.1 56.0 55.8 58.8 10.0 68.8 7 53.2 63.9 40.3 63.5 62.8 60.9 59.3 51.4 45.5 41.3 40.9 40.4 53.2 0.0 53.2 8 53.2 63.0 43.8 62.7 62.0 59.8 57.8 52.7 49.3 45.2 44.5 44.0 53.2 0.0 53.2 9 54.6 65.3 43.5 65.0 64.3 61.9 59.4 53.4 49.2 45.1 44.5 43.7 54.6 0.0 54.6 10 58.3 65.4 50.0 65.1 64.6 63.1 61.8 58.9 57.1 52.0 51.3 50.2 58.3 0.0 58.3 11 51.5 63.1 39.9 62.8 62.1 59.4 56.6 49.0 43.9 40.7 40.4 40.0 51.5 0.0 51.5 12 58.9 67.1 48.9 66.7 66.2 64.2 62.5 59.1 57.3 53.7 51.4 49.1 58.9 0.0 58.9 13 55.8 65.9 49.2 65.4 64.6 61.7 59.4 54.9 53.0 50.2 49.9 49.4 55.8 0.0 55.8 14 53.4 64.0 43.1 63.7 63.0 60.8 58.8 52.1 47.8 44.2 43.8 43.3 53.4 0.0 53.4 15 55.9 65.7 45.0 65.3 64.8 62.9 61.3 55.0 51.3 46.5 45.9 45.1 55.9 0.0 55.9 16 57.3 68.5 44.4 68.1 67.6 66.2 63.6 53.5 48.5 45.3 44.8 44.4 57.3 0.0 57.3 17 56.2 67.1 44.3 66.6 66.1 64.1 61.9 53.9 49.3 45.0 44.7 44.4 56.2 0.0 56.2 18 60.5 75.8 44.9 74.3 72.0 67.8 63.8 55.0 49.2 45.6 45.3 45.0 60.5 0.0 60.5 19 51.8 60.3 45.4 60.1 59.7 58.3 56.8 51.3 48.1 45.9 45.7 45.5 51.8 5.0 56.8 20 54.2 64.7 44.1 64.2 63.8 61.8 59.4 52.8 48.0 44.6 44.4 44.2 54.2 5.0 59.2 21 53.7 63.1 44.6 62.7 62.2 60.6 59.1 53.3 48.9 45.2 44.9 44.7 53.7 5.0 58.7 22 56.0 66.3 51.6 65.8 65.2 62.2 59.3 54.3 53.0 52.1 51.9 51.7 56.0 10.0 66.0 23 52.3 62.9 46.5 62.6 61.9 59.2 56.5 50.5 48.5 47.1 46.9 46.7 52.3 10.0 62.3 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 51.5 60.3 39.9 60.1 59.7 58.3 56.6 49.0 43.9 40.7 40.4 40.0 Max 60.5 75.8 50.0 74.3 72.0 67.8 63.8 59.1 57.3 53.7 51.4 50.2
56.0 65.1 64.4 62.2 60.1 53.8 49.8 46.0 45.5 44.9
Min 47.3 55.9 37.4 55.5 55.0 53.7 52.3 48.3 43.0 38.0 37.8 37.5 Max 58.8 67.3 55.8 66.8 66.0 63.2 62.5 59.1 57.1 56.2 56.0 55.9
55.6 61.8 61.3 59.6 58.0 54.4 51.2 49.2 49.0 48.7
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
62.2 56.0 55.6
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L1 - Located near the northwest corner of the Project Site near the Colony High School Football Field
57.3 56.5
56.4 51.647.3
55.2 58.8
53.253.2
54.6 58.3
51.5 58.9
55.8 53.4
55.9 57.3
56.2 60.5
51.8 54.2
53.7 56.0
52.3 35.0
40.0 45.0
50.0 55.0
60.0 65.0
70.0 75.0
80.0 85.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L1_A 93 6015
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 46.9 55.3 37.4 55.1 55.0 54.5 53.9 45.4 39.1 37.6 37.5 37.4 46.9 10.0 56.9 1 39.7 47.7 37.0 47.2 46.7 44.5 42.4 39.3 38.2 37.3 37.2 37.1 39.7 10.0 49.7 2 38.0 38.9 37.4 38.8 38.7 38.5 38.4 38.2 37.9 37.6 37.5 37.4 38.0 10.0 48.0 3 40.6 45.9 39.0 45.7 45.4 44.3 43.1 40.1 39.6 39.2 39.1 39.1 40.6 10.0 50.6 4 41.6 46.4 39.7 46.2 46.0 45.0 44.3 42.0 40.5 40.0 39.9 39.8 41.6 10.0 51.6 5 50.6 58.4 37.9 58.0 57.7 57.0 56.1 51.4 46.1 38.3 38.1 38.0 50.6 10.0 60.6 6 52.2 61.3 38.7 60.9 60.6 59.8 58.5 52.1 43.7 39.3 39.0 38.8 52.2 10.0 62.2 7 49.2 57.4 45.2 57.1 56.7 54.5 52.5 48.8 47.4 45.8 45.6 45.4 49.2 0.0 49.2 8 52.4 64.5 44.1 64.1 63.3 59.0 55.7 49.1 46.7 44.8 44.5 44.2 52.4 0.0 52.4 9 47.7 55.2 43.0 54.5 53.8 52.2 51.2 48.0 46.1 44.0 43.6 43.2 47.7 0.0 47.7 10 44.7 55.9 40.8 53.8 52.6 49.7 48.0 43.8 42.6 41.3 41.1 40.9 44.7 0.0 44.7 11 45.3 54.0 39.9 53.5 52.8 51.1 49.7 45.0 42.5 40.6 40.3 40.0 45.3 0.0 45.3 12 46.2 55.6 40.3 55.0 54.1 51.4 50.1 45.8 43.7 41.0 40.6 40.4 46.2 0.0 46.2 13 51.6 62.0 41.9 61.7 59.9 57.4 56.8 51.3 47.0 43.1 42.6 42.1 51.6 0.0 51.6 14 44.8 54.1 40.2 53.2 52.0 49.4 48.1 44.7 43.1 41.2 40.9 40.4 44.8 0.0 44.8 15 48.1 58.1 41.1 57.2 56.4 53.9 52.4 48.2 44.4 41.9 41.6 41.2 48.1 0.0 48.1 16 47.7 56.6 42.4 56.1 55.4 53.3 51.7 47.4 45.2 43.1 42.9 42.5 47.7 0.0 47.7 17 47.0 56.1 41.6 55.4 54.8 53.0 51.4 46.4 44.3 42.1 41.9 41.6 47.0 0.0 47.0 18 50.5 57.9 45.0 57.5 57.0 55.6 54.0 50.9 48.9 46.0 45.5 45.1 50.5 0.0 50.5 19 48.4 56.8 43.4 56.0 55.3 54.0 52.4 48.3 46.3 43.9 43.7 43.5 48.4 5.0 53.4 20 50.1 58.9 44.0 57.8 56.7 54.7 53.3 50.5 48.7 46.0 45.6 44.2 50.1 5.0 55.1 21 50.9 59.4 43.3 58.7 58.2 56.7 55.4 51.5 48.3 44.0 43.8 43.4 50.9 5.0 55.9 22 49.4 56.2 46.5 55.8 55.1 53.2 51.6 49.6 48.1 47.5 47.4 47.0 49.4 10.0 59.4 23 52.2 56.1 50.9 55.9 55.5 54.8 54.4 52.3 51.4 51.2 51.1 51.0 52.2 10.0 62.2 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 44.7 54.0 39.9 53.2 52.0 49.4 48.0 43.8 42.5 40.6 40.3 40.0 Max 52.4 64.5 45.2 64.1 63.3 59.0 56.8 51.5 48.9 46.0 45.6 45.4
48.9 56.8 55.9 53.7 52.2 48.0 45.7 43.3 42.9 42.5
Min 38.0 38.9 37.0 38.8 38.7 38.5 38.4 38.2 37.9 37.3 37.2 37.1 Max 52.2 61.3 50.9 60.9 60.6 59.8 58.5 52.3 51.4 51.2 51.1 51.0
48.4 51.5 51.2 50.2 49.2 45.6 42.7 40.9 40.8 40.6
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L2 - Located east of the Project Site just south of the existing residence at 3271 S Quincy Way.
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
55.3 48.9 48.4
46.939.738.040.641.650.652.249.252.447.744.745.346.251.644.848.147.747.050.548.450.150.949.452.2
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L2_E 94 6016
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 60.9 72.3 39.2 71.8 71.1 68.7 66.6 58.7 51.5 41.0 39.9 39.3 60.9 10.0 70.9 1 61.2 73.6 38.9 73.1 72.3 69.3 66.8 57.2 48.9 40.6 39.7 39.0 61.2 10.0 71.2 2 59.2 70.1 39.3 69.8 69.4 67.7 65.6 55.8 47.7 40.5 40.0 39.4 59.2 10.0 69.2 3 63.4 76.3 38.3 75.9 74.9 71.1 68.1 59.7 50.4 39.8 39.0 38.4 63.4 10.0 73.4 4 63.0 73.7 41.6 73.4 72.9 70.9 69.1 61.4 53.6 43.7 42.9 41.8 63.0 10.0 73.0 5 65.7 76.0 43.9 75.7 75.3 73.2 71.4 65.2 57.8 46.6 45.3 44.1 65.7 10.0 75.7 6 66.7 76.3 47.4 76.0 75.5 73.5 72.0 67.3 60.3 50.5 48.8 47.5 66.7 10.0 76.7 7 67.7 77.1 50.2 76.9 76.4 74.4 72.9 68.0 62.5 53.4 51.9 50.4 67.7 0.0 67.7 8 68.5 77.2 52.1 77.0 76.6 75.0 74.0 69.3 64.2 55.3 53.9 52.4 68.5 0.0 68.5 9 68.8 77.7 53.1 77.5 77.1 75.1 73.8 69.6 65.0 56.4 54.9 53.4 68.8 0.0 68.8 10 68.8 76.9 52.9 76.6 76.3 74.6 73.4 70.1 65.7 56.7 55.0 53.3 68.8 0.0 68.8 11 69.5 77.2 52.1 76.9 76.5 74.9 74.1 71.0 66.8 56.6 54.6 52.5 69.5 0.0 69.5 12 69.5 76.8 55.8 76.6 76.2 74.8 74.0 70.8 67.2 59.1 57.4 56.0 69.5 0.0 69.5 13 69.3 77.0 53.5 76.8 76.4 74.8 73.9 70.5 66.7 58.0 55.8 53.8 69.3 0.0 69.3 14 69.2 76.9 56.1 76.6 76.2 74.9 73.7 70.4 66.7 59.8 58.1 56.4 69.2 0.0 69.2 15 69.5 76.3 57.1 76.1 75.7 74.4 73.6 70.9 68.0 60.6 58.9 57.3 69.5 0.0 69.5 16 69.8 78.0 56.7 77.7 77.0 74.9 73.7 70.9 67.8 60.8 58.7 57.0 69.8 0.0 69.8 17 70.1 76.8 58.5 76.5 76.1 74.9 74.0 71.3 68.7 62.1 60.7 58.9 70.1 0.0 70.1 18 69.4 76.7 57.6 76.3 75.9 74.4 73.4 70.6 67.8 60.8 59.4 58.0 69.4 0.0 69.4 19 69.6 79.1 53.7 78.6 77.7 75.1 73.6 70.6 66.7 58.0 56.2 54.0 69.6 5.0 74.6 20 68.5 77.5 52.5 77.2 76.7 74.7 73.3 69.4 64.8 55.5 54.2 52.7 68.5 5.0 73.5 21 68.3 80.1 48.8 79.3 78.0 74.7 72.3 68.3 63.5 52.3 50.5 48.9 68.3 5.0 73.3 22 65.8 75.3 47.7 74.9 74.4 72.5 71.3 66.3 60.0 50.5 49.1 48.0 65.8 10.0 75.8 23 64.7 74.4 45.9 74.1 73.8 71.9 70.3 64.7 58.3 48.9 47.3 46.1 64.7 10.0 74.7 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 67.7 76.3 48.8 76.1 75.7 74.4 72.3 68.0 62.5 52.3 50.5 48.9 Max 70.1 80.1 58.5 79.3 78.0 75.1 74.1 71.3 68.7 62.1 60.7 58.9
69.1 77.1 76.6 74.8 73.6 70.1 66.1 57.7 56.0 54.3
Min 59.2 70.1 38.3 69.8 69.4 67.7 65.6 55.8 47.7 39.8 39.0 38.4 Max 66.7 76.3 47.7 76.0 75.5 73.5 72.0 67.3 60.3 50.5 49.1 48.0
64.0 73.9 73.3 71.0 69.0 61.8 54.3 44.7 43.5 42.6
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
72.2 69.1 64.0
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L3 - Located within the Rich Haven Specific Plan north of Ontario Ranch Road.
60.9 61.2
59.2 63.4
63.0 65.7
66.7 67.7
68.5 68.8
68.8 69.569.5
69.3 69.2
69.5 69.8
70.1 69.4
69.6 68.5
68.3 65.8
64.7 35.0
40.0 45.0
50.0 55.0
60.0 65.0
70.0 75.0
80.0 85.0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L3_H 95 6017
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 45.4 51.4 40.9 51.2 51.0 50.1 49.3 46.7 42.4 41.4 41.2 41.0 45.4 10.0 55.4 1 42.7 45.3 41.2 45.0 44.8 44.2 43.8 43.0 42.5 41.6 41.5 41.3 42.7 10.0 52.7 2 42.8 46.7 40.7 46.4 46.0 45.2 44.7 43.4 42.2 41.2 41.0 40.9 42.8 10.0 52.8 3 43.0 46.3 41.1 46.0 45.7 45.1 44.8 43.5 42.6 41.6 41.4 41.2 43.0 10.0 53.0 4 44.3 48.8 42.0 48.4 48.0 47.1 46.5 44.7 43.8 42.6 42.4 42.1 44.3 10.0 54.3 5 53.0 62.6 45.3 62.2 61.6 59.4 57.5 53.3 49.4 45.9 45.6 45.4 53.0 10.0 63.0 6 59.9 72.1 49.8 71.7 70.7 66.9 63.8 57.4 53.9 50.7 50.4 50.0 59.9 10.0 69.9 7 59.2 71.2 49.9 70.7 70.0 66.8 63.4 56.0 52.7 50.6 50.3 50.0 59.2 0.0 59.2 8 57.0 70.0 47.9 69.5 68.5 64.1 60.6 52.5 50.0 48.6 48.4 48.0 57.0 0.0 57.0 9 57.4 70.7 46.2 70.1 69.1 65.4 61.4 51.4 48.7 46.9 46.7 46.4 57.4 0.0 57.4 10 59.8 71.5 48.4 71.0 70.3 67.3 64.1 58.0 54.1 49.8 49.3 48.7 59.8 0.0 59.8 11 57.1 70.7 43.9 69.7 68.4 64.9 61.7 51.9 48.2 45.1 44.6 44.1 57.1 0.0 57.1 12 59.1 71.7 44.4 71.3 70.6 67.7 64.2 53.3 48.8 45.4 45.1 44.5 59.1 0.0 59.1 13 54.7 66.1 43.3 65.9 65.2 62.5 59.9 52.0 47.4 44.3 43.9 43.5 54.7 0.0 54.7 14 56.9 69.3 46.0 68.9 68.1 64.4 61.0 53.3 49.9 47.0 46.6 46.1 56.9 0.0 56.9 15 55.8 67.6 44.4 67.3 66.7 63.4 60.3 52.6 48.6 45.3 44.9 44.5 55.8 0.0 55.8 16 53.3 65.6 44.0 65.2 64.4 61.0 57.7 49.4 46.7 44.8 44.5 44.1 53.3 0.0 53.3 17 52.2 62.9 44.9 62.3 61.3 59.3 57.6 50.4 47.6 45.6 45.3 45.0 52.2 0.0 52.2 18 54.6 66.6 47.4 66.1 65.0 61.2 57.6 52.2 50.2 48.1 47.9 47.5 54.6 0.0 54.6 19 52.2 62.0 47.6 61.6 60.7 57.8 55.6 51.5 49.7 48.2 47.9 47.7 52.2 5.0 57.2 20 49.9 58.6 46.6 58.2 57.7 55.1 52.7 48.9 48.1 47.1 46.9 46.7 49.9 5.0 54.9 21 52.3 62.4 45.8 62.0 61.2 58.4 56.3 51.6 48.6 46.4 46.2 45.9 52.3 5.0 57.3 22 50.9 61.5 44.7 61.1 60.4 57.4 55.0 49.7 46.6 45.2 45.0 44.8 50.9 10.0 60.9 23 45.4 52.4 42.7 52.2 51.7 49.9 48.3 45.0 44.0 43.1 43.0 42.8 45.4 10.0 55.4 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 49.9 58.6 43.3 58.2 57.7 55.1 52.7 48.9 46.7 44.3 43.9 43.5 Max 59.8 71.7 49.9 71.3 70.6 67.7 64.2 58.0 54.1 50.6 50.3 50.0
56.3 66.7 65.8 62.6 59.6 52.3 49.3 46.9 46.6 46.2
Min 42.7 45.3 40.7 45.0 44.8 44.2 43.8 43.0 42.2 41.2 41.0 40.9 Max 59.9 72.1 49.8 71.7 70.7 66.9 63.8 57.4 53.9 50.7 50.4 50.0
52.1 53.8 53.3 51.7 50.4 47.4 45.3 43.7 43.5 43.3
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L4 - Located south of the Project Site near the existing residence at 10823 Edison Avenue.
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
59.6 56.3 52.1
45.442.742.843.044.353.0
59.9 59.2
57.0 57.4
59.8 57.1
59.1 54.7
56.9 55.8
53.3 52.2
54.6 52.249.952.350.945.4
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L4_I 96 6018
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 50.6 61.0 40.1 60.8 60.2 57.8 55.8 49.9 43.8 40.5 40.3 40.1 50.6 10.0 60.6 1 48.8 58.7 39.7 58.4 57.9 55.7 54.2 47.6 43.1 40.4 40.1 39.8 48.8 10.0 58.8 2 49.2 60.5 38.8 60.2 59.6 56.6 54.4 47.0 42.3 39.3 39.1 38.9 49.2 10.0 59.2 3 52.4 63.1 39.9 62.8 62.3 60.0 57.8 51.0 45.5 40.9 40.4 40.0 52.4 10.0 62.4 4 56.2 67.2 41.9 66.8 66.2 63.8 61.6 55.0 48.9 42.9 42.4 42.0 56.2 10.0 66.2 5 56.3 66.5 41.4 66.1 65.6 63.4 61.9 55.6 50.3 43.5 42.3 41.6 56.3 10.0 66.3 6 58.9 69.2 44.1 68.9 68.3 66.2 64.5 58.1 53.7 46.3 45.3 44.3 58.9 10.0 68.9 7 59.3 70.3 45.9 70.0 69.1 66.2 64.2 58.3 54.2 48.1 47.2 46.1 59.3 0.0 59.3 8 61.3 71.9 48.1 71.4 70.7 68.1 66.2 60.9 56.5 50.3 49.4 48.4 61.3 0.0 61.3 9 60.8 70.4 49.2 70.0 69.2 66.7 65.2 61.0 57.6 51.6 50.6 49.5 60.8 0.0 60.8 10 60.5 70.4 45.2 70.1 69.5 67.3 65.6 60.2 56.0 48.4 46.6 45.4 60.5 0.0 60.5 11 63.2 73.5 51.8 73.1 72.5 69.8 67.8 62.4 59.4 53.7 52.9 52.1 63.2 0.0 63.2 12 62.3 72.4 49.2 72.1 71.4 69.0 67.1 61.9 57.9 52.0 50.7 49.5 62.3 0.0 62.3 13 60.5 70.6 48.8 70.3 69.7 67.5 65.3 59.7 56.5 50.7 49.9 49.1 60.5 0.0 60.5 14 64.8 77.4 50.2 77.0 76.1 71.8 68.1 62.2 58.2 52.5 51.6 50.5 64.8 0.0 64.8 15 66.1 75.4 54.3 74.9 74.2 71.6 70.3 66.4 63.4 57.8 55.6 54.6 66.1 0.0 66.1 16 66.1 77.7 52.6 77.3 76.5 74.1 71.1 64.0 59.9 54.7 53.8 52.8 66.1 0.0 66.1 17 62.6 72.2 52.8 71.8 70.9 68.4 66.7 62.7 59.7 54.9 53.7 53.0 62.6 0.0 62.6 18 62.8 71.3 52.3 71.0 70.5 68.7 67.3 63.3 60.3 54.2 53.3 52.6 62.8 0.0 62.8 19 63.7 75.9 51.9 75.4 74.6 71.1 68.0 61.1 57.9 53.4 52.8 52.1 63.7 5.0 68.7 20 59.9 70.6 48.0 70.3 69.7 67.4 65.0 58.8 54.8 49.7 48.8 48.1 59.9 5.0 64.9 21 64.3 76.7 55.6 76.0 75.3 70.2 67.4 62.0 59.9 56.6 56.1 55.7 64.3 5.0 69.3 22 57.3 67.2 44.9 66.9 66.2 63.9 62.2 57.3 52.1 46.1 45.5 45.0 57.3 10.0 67.3 23 54.5 65.4 41.6 65.1 64.5 61.9 59.6 53.5 48.1 42.4 42.0 41.7 54.5 10.0 64.5 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 59.3 70.3 45.2 70.0 69.1 66.2 64.2 58.3 54.2 48.1 46.6 45.4 Max 66.1 77.7 55.6 77.3 76.5 74.1 71.1 66.4 63.4 57.8 56.1 55.7
63.1 72.7 72.0 69.2 67.0 61.7 58.2 52.6 51.5 50.6
Min 48.8 58.7 38.8 58.4 57.9 55.7 54.2 47.0 42.3 39.3 39.1 38.9 Max 58.9 69.2 44.9 68.9 68.3 66.2 64.5 58.1 53.7 46.3 45.5 45.0
55.1 64.0 63.4 61.0 59.1 52.8 47.5 42.5 41.9 41.5
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
64.8 63.1 55.1
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L5 - Located within the Rich Haven Specific Plan near the existing residence at 3965 S Sunrise Avenue.
50.648.849.252.4
56.2 56.3
58.9 59.3
61.3 60.8
60.5 63.2
62.3 60.5
64.8 66.1
66.1 62.6
62.8 63.7
59.9 64.3
57.3 54.5
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L5_G 97 6019
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 57.3 69.1 39.5 68.6 67.9 65.2 62.9 54.3 47.1 40.4 39.9 39.5 57.3 10.0 67.3 1 52.5 64.6 38.2 64.2 63.7 60.7 58.0 47.1 40.9 38.7 38.5 38.3 52.5 10.0 62.5 2 54.8 67.4 37.2 66.8 66.3 63.3 60.3 48.7 41.6 37.8 37.5 37.3 54.8 10.0 64.8 3 53.7 66.2 37.0 65.6 65.1 62.0 59.3 48.6 42.2 37.7 37.5 37.1 53.7 10.0 63.7 4 59.8 71.4 39.0 71.0 70.5 67.8 65.8 57.0 49.0 40.8 40.0 39.2 59.8 10.0 69.8 5 64.0 74.6 45.2 74.1 73.4 71.2 69.6 63.5 57.1 47.5 46.0 45.3 64.0 10.0 74.0 6 64.8 74.2 48.6 73.8 73.3 71.3 70.2 65.5 59.1 50.5 49.6 48.7 64.8 10.0 74.8 7 67.8 77.4 51.9 77.0 76.3 74.4 72.8 68.4 63.6 54.8 53.4 52.3 67.8 0.0 67.8 8 66.9 75.9 50.9 75.4 74.9 73.3 71.9 67.9 62.7 53.6 52.1 51.1 66.9 0.0 66.9 9 67.7 76.7 50.8 76.3 75.8 74.0 72.8 68.8 63.3 53.1 52.0 51.0 67.7 0.0 67.7 10 66.8 75.8 50.3 75.3 74.8 73.0 71.8 68.0 62.7 52.8 51.5 50.5 66.8 0.0 66.8 11 69.7 79.3 52.0 78.9 78.3 76.3 74.9 70.3 65.2 55.4 53.7 52.3 69.7 0.0 69.7 12 68.3 76.6 52.2 76.1 75.5 74.0 73.0 69.8 65.1 55.6 53.8 52.6 68.3 0.0 68.3 13 68.1 77.1 51.7 76.6 76.2 74.6 73.1 69.1 64.0 55.5 53.8 52.1 68.1 0.0 68.1 14 69.1 78.1 53.3 77.6 77.1 75.1 73.6 70.0 65.9 56.7 54.8 53.5 69.1 0.0 69.1 15 68.9 78.0 55.4 77.6 76.9 74.5 73.4 69.8 66.1 58.0 56.9 55.6 68.9 0.0 68.9 16 69.1 77.8 54.9 77.4 77.1 75.1 73.6 70.0 66.0 58.0 56.3 55.1 69.1 0.0 69.1 17 69.2 80.3 56.0 79.6 78.5 75.8 73.7 69.1 64.9 58.1 57.0 56.2 69.2 0.0 69.2 18 69.5 81.2 55.4 80.5 79.2 76.3 74.0 68.6 64.5 57.6 56.6 55.6 69.5 0.0 69.5 19 68.1 75.9 54.4 75.5 75.1 73.9 72.9 69.4 65.2 57.0 55.6 54.6 68.1 5.0 73.1 20 71.4 83.4 53.0 83.0 82.2 79.2 75.4 69.5 64.1 55.6 54.3 53.2 71.4 5.0 76.4 21 69.6 79.1 51.7 78.8 78.2 76.6 75.3 69.8 63.1 54.0 52.7 51.8 69.6 5.0 74.6 22 66.6 76.6 48.1 76.1 75.6 73.7 72.4 66.6 60.6 51.1 49.6 48.4 66.6 10.0 76.6 23 65.1 75.7 45.0 75.2 74.6 72.4 70.6 64.9 56.7 47.0 45.8 45.1 65.1 10.0 75.1 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 66.8 75.8 50.3 75.3 74.8 73.0 71.8 67.9 62.7 52.8 51.5 50.5 Max 71.4 83.4 56.0 83.0 82.2 79.2 75.4 70.3 66.1 58.1 57.0 56.2
68.8 77.7 77.1 75.1 73.5 69.2 64.4 55.7 54.3 53.2
Min 52.5 64.6 37.0 64.2 63.7 60.7 58.0 47.1 40.9 37.7 37.5 37.1 Max 66.6 76.6 48.6 76.1 75.6 73.7 72.4 66.6 60.6 51.1 49.6 48.7
62.4 70.6 70.0 67.5 65.5 57.4 50.5 43.5 42.7 42.1
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
71.4 68.8 62.4
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L6 - Located west of the Project Site near the existing residence at 3860 S Oasis Paseo
57.3 52.5
54.8 53.7
59.8 64.0
64.8 67.8
66.9 67.7
66.8 69.7
68.3 68.1
69.1 68.9
69.1 69.2
69.5 68.1
71.4 69.6
66.6 65.1
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L6_S 98 6020
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 54.7 66.4 38.8 66.1 65.4 62.3 60.3 52.1 43.6 39.4 39.1 38.9 54.7 10.0 64.7 1 50.8 62.8 40.5 62.4 61.7 58.8 56.1 47.0 42.3 40.9 40.7 40.6 50.8 10.0 60.8 2 55.5 68.6 40.8 68.2 67.3 64.1 60.0 48.6 42.6 41.2 41.1 40.9 55.5 10.0 65.5 3 51.2 62.3 41.6 62.0 61.6 59.4 56.7 47.9 43.2 42.1 42.0 41.7 51.2 10.0 61.2 4 58.0 69.0 41.6 68.7 68.1 66.2 64.2 55.8 48.4 42.6 42.1 41.8 58.0 10.0 68.0 5 63.0 73.3 46.6 73.0 72.6 70.3 68.4 62.7 56.2 47.8 47.1 46.7 63.0 10.0 73.0 6 63.6 71.3 52.8 71.0 70.6 69.3 68.3 65.0 60.6 54.2 53.6 52.9 63.6 10.0 73.6 7 65.8 74.6 53.8 74.3 73.9 72.2 70.5 66.2 62.8 56.5 55.0 53.9 65.8 0.0 65.8 8 66.4 78.9 53.0 78.0 76.6 71.6 69.6 65.5 61.8 55.5 54.4 53.3 66.4 0.0 66.4 9 64.3 73.9 48.8 73.6 73.1 71.1 69.3 64.8 59.5 51.2 50.1 49.0 64.3 0.0 64.3 10 63.4 72.1 48.5 71.9 71.3 69.3 67.9 64.4 59.9 50.9 49.6 48.7 63.4 0.0 63.4 11 63.7 74.2 46.2 73.7 72.7 70.1 68.2 64.2 59.5 49.6 48.1 46.6 63.7 0.0 63.7 12 62.2 70.2 45.2 70.0 69.5 67.9 66.7 63.7 59.5 48.8 46.9 45.5 62.2 0.0 62.2 13 65.9 78.1 52.5 77.2 76.1 72.8 69.5 64.6 61.1 55.1 53.9 52.8 65.9 0.0 65.9 14 66.2 76.5 53.8 76.0 75.2 72.8 70.9 65.8 62.4 56.4 55.3 54.1 66.2 0.0 66.2 15 66.8 77.7 53.7 77.3 76.6 73.9 71.1 65.9 62.3 56.3 55.0 54.0 66.8 0.0 66.8 16 67.6 79.7 53.2 79.4 78.2 74.1 71.2 66.0 63.0 56.7 55.1 53.6 67.6 0.0 67.6 17 64.5 72.7 52.6 72.2 71.4 69.6 68.6 65.6 62.6 55.9 54.5 52.9 64.5 0.0 64.5 18 66.4 77.5 53.3 76.9 76.1 72.5 70.5 65.7 62.5 56.1 54.9 53.6 66.4 0.0 66.4 19 65.7 76.7 52.6 76.2 75.4 72.5 69.6 65.2 62.0 55.2 54.0 53.0 65.7 5.0 70.7 20 64.4 75.2 47.5 74.8 74.2 71.3 68.7 64.1 59.9 50.8 49.4 47.8 64.4 5.0 69.4 21 64.5 75.9 47.8 75.6 75.0 71.8 68.9 63.6 58.5 49.6 48.7 47.9 64.5 5.0 69.5 22 63.2 75.4 45.9 74.7 73.5 70.2 68.2 62.2 56.2 47.2 46.5 46.0 63.2 10.0 73.2 23 61.7 72.4 43.8 72.0 71.4 69.2 67.0 61.3 54.9 45.3 44.6 44.0 61.7 10.0 71.7 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 62.2 70.2 45.2 70.0 69.5 67.9 66.7 63.6 58.5 48.8 46.9 45.5 Max 67.6 79.7 53.8 79.4 78.2 74.1 71.2 66.2 63.0 56.7 55.3 54.1
65.4 75.1 74.4 71.6 69.4 65.0 61.2 53.6 52.3 51.1
Min 50.8 62.3 38.8 62.0 61.6 58.8 56.1 47.0 42.3 39.4 39.1 38.9 Max 63.6 75.4 52.8 74.7 73.5 70.3 68.4 65.0 60.6 54.2 53.6 52.9
60.2 68.7 68.0 65.5 63.2 55.8 49.8 44.5 44.1 43.7
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
68.4 65.4 60.2
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L7 - Located west of the Project Site near the existing residence at 3393 Clover Place
54.7 50.8
55.5 51.2
58.0 63.0
63.6 65.8
66.4 64.3
63.4 63.7
62.2 65.9
66.2 66.8
67.6 64.5
66.4 65.7
64.4 64.5
63.2 61.7
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L7_X 99 6021
Date: Location: Meter: Piccolo II JN: 14822
Project: Rich Haven SP Source: Analyst: B. Lawson
Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% L eq Adj. Adj. L eq 0 59.2 70.5 47.0 70.2 69.5 66.8 64.4 57.4 51.8 48.0 47.6 47.1 59.2 10.0 69.2 1 57.1 68.4 44.4 68.1 67.6 65.2 62.7 54.2 49.0 45.6 45.1 44.6 57.1 10.0 67.1 2 56.5 68.3 42.5 68.0 67.5 64.8 62.0 52.1 47.9 43.5 43.0 42.6 56.5 10.0 66.5 3 59.8 70.8 45.2 70.5 70.0 67.9 65.6 57.3 51.3 46.4 45.8 45.3 59.8 10.0 69.8 4 63.1 73.5 50.6 73.3 72.8 70.2 68.4 62.0 57.0 51.7 51.1 50.7 63.1 10.0 73.1 5 65.6 75.1 54.1 74.7 74.1 72.1 70.9 65.9 61.3 55.8 54.9 54.2 65.6 10.0 75.6 6 66.9 75.7 56.3 75.4 74.8 72.9 71.6 67.4 63.8 57.8 57.0 56.5 66.9 10.0 76.9 7 68.4 77.0 59.9 76.6 75.8 73.8 72.5 69.1 66.2 61.4 60.6 60.0 68.4 0.0 68.4 8 68.4 76.4 60.3 76.0 75.4 73.7 72.5 69.2 66.0 61.7 61.1 60.5 68.4 0.0 68.4 9 67.1 75.7 55.4 75.3 74.8 73.1 71.9 67.9 63.9 57.4 56.5 55.6 67.1 0.0 67.1 10 68.1 77.5 56.0 77.1 76.5 74.2 72.8 68.6 64.1 58.1 57.2 56.2 68.1 0.0 68.1 11 68.5 78.3 56.3 77.8 77.1 74.9 73.2 68.9 64.8 58.3 57.4 56.5 68.5 0.0 68.5 12 66.8 76.2 55.9 75.9 75.2 73.5 71.8 66.8 62.8 57.4 56.6 56.1 66.8 0.0 66.8 13 66.1 75.2 56.3 74.5 73.8 71.7 70.4 66.8 63.1 57.8 57.0 56.5 66.1 0.0 66.1 14 68.5 77.7 57.7 77.3 76.8 74.5 73.2 68.6 65.2 59.6 58.8 57.9 68.5 0.0 68.5 15 67.9 76.6 60.4 76.1 75.2 72.7 71.5 68.3 66.1 62.0 61.3 60.6 67.9 0.0 67.9 16 68.7 78.8 58.5 78.3 77.5 75.0 73.1 68.4 65.3 60.2 59.4 58.7 68.7 0.0 68.7 17 71.7 84.5 59.3 83.9 82.9 76.9 75.0 69.6 65.8 60.9 60.1 59.4 71.7 0.0 71.7 18 69.6 81.1 58.5 80.7 79.8 76.4 73.4 68.4 65.2 60.0 59.4 58.7 69.6 0.0 69.6 19 68.2 79.0 57.3 78.5 77.7 75.1 72.6 67.3 63.7 58.7 58.1 57.5 68.2 5.0 73.2 20 68.5 82.1 55.2 80.6 79.2 75.4 71.9 66.4 62.1 56.9 56.1 55.4 68.5 5.0 73.5 21 68.0 78.5 54.3 78.1 77.6 75.8 73.8 66.1 61.4 55.8 55.0 54.5 68.0 5.0 73.0 22 65.2 75.0 53.5 74.7 74.1 71.7 70.1 65.2 60.7 55.2 54.4 53.7 65.2 10.0 75.2 23 68.8 81.0 55.5 80.6 79.9 77.0 73.4 65.2 60.8 56.5 56.0 55.6 68.8 10.0 78.8 Timeframe Hour L eq L max L min L1% L2% L5% L8% L25% L50% L90% L95% L99% Min 66.1 75.2 54.3 74.5 73.8 71.7 70.4 66.1 61.4 55.8 55.0 54.5 Max 71.7 84.5 60.4 83.9 82.9 76.9 75.0 69.6 66.2 62.0 61.3 60.6
68.5 77.8 77.0 74.4 72.6 68.0 64.4 59.1 58.3 57.6
Min 56.5 68.3 42.5 68.0 67.5 64.8 62.0 52.1 47.9 43.5 43.0 42.6 Max 68.8 81.0 56.3 80.6 79.9 77.0 73.4 67.4 63.8 57.8 57.0 56.5
64.3 72.8 72.3 69.8 67.7 60.7 55.9 51.2 50.5 50.0
24-Hour Noise Level Measurement Summary
Hourly L eq dBA Readings (unadjusted)
Night
Friday, September 30, 2022 L8 - Located north of the Project Site near the existing residence at 2943 S Alder Creek Drive.
Night
Day
Leq (dBA) 24-Hour
Day CNEL
Night
Energy Average
Energy Average Average:
Average:
Daytime
(7am-10pm)
Nighttime
(10pm-7am)
72.1 68.5 64.3
59.2 57.1
56.5 59.8
63.1 65.6
66.9 68.4
68.4 67.1
68.1 68.5
66.8 66.1
68.5 67.9
68.7 71.7
69.6 68.2
68.5 68.0
65.2 68.8
35.0 40.0
45.0 50.0
55.0 60.0
65.0 70.0
75.0 80.0
85.0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Hourly Leq (dBA)
Hour Beginning
Z:\Shared\UcJobs\_14600-15000\_14800\14822\04_Noise\Fieldwork\Measurements\14822_L8_Z 100
6022
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
APPENDIX 7.1:
OFF-SITE TRAFFIC NOISE CONTOURS
101
6023
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
102
6024
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Archibald Av.
Scenario: E
21,909
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,733 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.95
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.48 0.61 -1.20 0.000 0.000
86.40 -9.89 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.2 68.9 67.2 64.1 71.5 71.9
65.3 75.9
64.7 57.0 58.4 66.1 66.3
74.6 70.1 71.0 78.0 78.2
Vehicle Noise: 77.2 76.0 72.0 72.0 79.1 79.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
243 523 1,127 2,429
251 542 1,167 2,514
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Archibald Av.
Scenario: E+P
26,968
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,133 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.08 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.06%
82.2% 3.5% 14.3% 1.97%
70.8% 6.2% 23.0% 8.97%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.48 0.61 -1.20 0.000 0.000
86.40 -9.89 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.2 70.0 68.2 65.2 72.6 73.0
65.3 75.9
64.7 57.0 58.4 66.1 66.3
74.6 70.1 71.0 78.0 78.2
Vehicle Noise: 77.5 76.2 72.4 72.2 79.3 79.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
250 539 1,162 2,504
259 559 1,204 2,595
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Archibald Av.
Scenario: OY
26,337
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,083 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.68 0.61 -1.20 0.000 0.000
86.40 -9.09 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.0 69.7 68.0 64.9 72.3 72.7
66.1 76.7
65.5 57.8 59.2 66.9 67.1
75.4 70.9 71.8 78.8 79.0
Vehicle Noise: 78.0 76.8 72.8 72.8 79.9 80.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
275 592 1,274 2,746
284 612 1,319 2,842
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Archibald Av.
Scenario: OY+P
31,396
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,483 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.72 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.70%
82.2% 3.5% 14.3% 2.03%
70.8% 6.2% 23.0% 9.27%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.68 0.61 -1.20 0.000 0.000
86.40 -9.09 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.9 70.6 68.8 65.8 73.2 73.6
66.1 76.7
65.5 57.8 59.2 66.9 67.1
75.4 70.9 71.8 78.8 79.0
Vehicle Noise: 78.2 77.0 73.1 73.0 80.1 80.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
282 607 1,307 2,816
292 629 1,355 2,918
Friday, October 14, 2022
103
6025
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Archibald Av.
Scenario: HY
37,904
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,998 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.43 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.10 0.61 -1.20 0.000 0.000
86.40 -7.51 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.6 71.3 69.6 66.5 73.9 74.3
67.7 78.3
67.1 59.4 60.7 68.5 68.7
77.0 72.5 73.4 80.4 80.6
Vehicle Noise: 79.6 78.4 74.4 74.4 81.5 81.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
350 754 1,625 3,500
362 780 1,681 3,623
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Archibald Av.
Scenario: HY+P
42,963
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,398 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.05 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.12%
82.2% 3.5% 14.3% 2.14%
70.8% 6.2% 23.0% 9.75%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.10 0.61 -1.20 0.000 0.000
86.40 -7.51 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.2 71.9 70.2 67.1 74.5 75.0
67.7 78.3
67.1 59.4 60.7 68.5 68.7
77.0 72.5 73.4 80.4 80.6
Vehicle Noise: 79.8 78.5 74.6 74.5 81.6 81.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
356 768 1,654 3,563
369 795 1,713 3,690
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Haven Av.
Scenario: E
18,527
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,465 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.68
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.21 0.61 -1.20 0.000 0.000
86.40 -10.62 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.5 68.2 66.4 63.4 70.8 71.2
64.6 75.2
64.0 56.3 57.6 65.4 65.6
73.9 69.4 70.3 77.3 77.5
Vehicle Noise: 76.5 75.3 71.3 71.3 78.4 78.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
217 468 1,008 2,172
225 484 1,043 2,248
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Haven Av.
Scenario: E+P
34,509
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,730 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.33 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.77%
82.2% 3.5% 14.3% 1.30%
70.8% 6.2% 23.0% 5.93%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.21 0.61 -1.20 0.000 0.000
86.40 -10.62 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.5 71.2 69.4 66.4 73.8 74.2
64.6 75.2
64.0 56.3 57.6 65.4 65.6
73.9 69.4 70.3 77.3 77.5
Vehicle Noise: 77.3 76.1 72.5 71.9 79.1 79.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
242 521 1,122 2,418
251 541 1,166 2,513
Friday, October 14, 2022
104
6026
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Haven Av.
Scenario: OY
26,968
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,133 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.05
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.58 0.61 -1.20 0.000 0.000
86.40 -8.99 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.1 69.8 68.1 65.0 72.4 72.9
66.2 76.8
65.6 57.9 59.3 67.0 67.2
75.5 71.0 71.9 78.9 79.1
Vehicle Noise: 78.1 76.9 72.9 72.9 80.0 80.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
279 601 1,295 2,789
289 622 1,340 2,887
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Haven Av.
Scenario: OY+P
42,951
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,397 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.22 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.54%
82.2% 3.5% 14.3% 1.52%
70.8% 6.2% 23.0% 6.94%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.58 0.61 -1.20 0.000 0.000
86.40 -8.99 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.4 72.1 70.3 67.3 74.7 75.1
66.2 76.8
65.6 57.9 59.3 67.0 67.2
75.5 71.0 71.9 78.9 79.1
Vehicle Noise: 78.7 77.5 73.8 73.4 80.5 80.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
301 648 1,396 3,008
312 673 1,450 3,123
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Haven Av.
Scenario: HY
33,655
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,662 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.92 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.62 0.61 -1.20 0.000 0.000
86.40 -8.02 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.1 70.8 69.0 66.0 73.4 73.8
67.2 77.8
66.6 58.9 60.2 68.0 68.1
76.5 72.0 72.9 79.9 80.0
Vehicle Noise: 79.1 77.9 73.9 73.9 81.0 81.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
323 697 1,501 3,233
335 721 1,553 3,347
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Haven Av.
Scenario: HY+P
49,637
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,926 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.82 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.87%
82.2% 3.5% 14.3% 1.64%
70.8% 6.2% 23.0% 7.49%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.62 0.61 -1.20 0.000 0.000
86.40 -8.02 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.0 72.7 70.9 67.9 75.3 75.7
67.2 77.8
66.6 58.9 60.2 68.0 68.1
76.5 72.0 72.9 79.9 80.0
Vehicle Noise: 79.6 78.3 74.6 74.2 81.4 81.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
344 741 1,595 3,437
357 768 1,655 3,567
Friday, October 14, 2022
105
6027
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Haven Av.
Scenario: E
10,432
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 825 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
-3.76
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -19.29 1.46 -1.20 0.000 0.000
85.38 -12.70 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.7 65.4 63.6 60.6 68.0 68.4
62.0 72.9
61.3 53.6 55.0 62.8 62.9
71.7 67.1 68.0 75.0 75.2
Vehicle Noise: 74.1 72.9 68.9 68.9 76.0 76.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
126 271 584 1,259
130 281 605 1,303
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Haven Av.
Scenario: E+P
28,244
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,234 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
0.97 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 95.03%
82.2% 3.5% 14.3% 0.89%
70.8% 6.2% 23.0% 4.08%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -19.29 1.46 -1.20 0.000 0.000
85.38 -12.70 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.4 70.1 68.4 65.3 72.7 73.1
62.0 72.9
61.3 53.6 55.0 62.8 62.9
71.7 67.1 68.0 75.0 75.2
Vehicle Noise: 75.4 74.2 70.9 70.0 77.2 77.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
151 325 700 1,509
157 339 729 1,571
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Haven Av.
Scenario: OY
20,983
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,660 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
-0.72
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -16.26 1.46 -1.20 0.000 0.000
85.38 -9.66 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.7 68.4 66.7 63.6 71.0 71.4
65.0 76.0
64.4 56.7 58.0 65.8 66.0
74.7 70.2 71.1 78.1 78.2
Vehicle Noise: 77.2 75.9 71.9 72.0 79.1 79.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
201 432 931 2,007
208 447 963 2,076
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Haven Av.
Scenario: OY+P
38,795
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,069 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
2.25 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.72%
82.2% 3.5% 14.3% 1.31%
70.8% 6.2% 23.0% 5.97%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -16.26 1.46 -1.20 0.000 0.000
85.38 -9.66 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.7 71.4 69.6 66.6 74.0 74.4
65.0 76.0
64.4 56.7 58.0 65.8 66.0
74.7 70.2 71.1 78.1 78.2
Vehicle Noise: 77.9 76.6 73.0 72.5 79.7 79.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
221 476 1,025 2,209
229 494 1,065 2,294
Friday, October 14, 2022
106
6028
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Haven Av.
Scenario: HY
28,411
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,247 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
0.59 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -14.94 1.46 -1.20 0.000 0.000
85.38 -8.35 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.0 69.7 68.0 64.9 72.3 72.8
66.3 77.3
65.7 58.0 59.4 67.1 67.3
76.0 71.5 72.4 79.4 79.6
Vehicle Noise: 78.5 77.3 73.2 73.3 80.4 80.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
246 529 1,140 2,456
254 547 1,179 2,540
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Haven Av.
Scenario: HY+P
46,224
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,656 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
2.96 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.72%
82.2% 3.5% 14.3% 1.49%
70.8% 6.2% 23.0% 6.79%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -14.94 1.46 -1.20 0.000 0.000
85.38 -8.35 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.4 72.1 70.3 67.3 74.7 75.1
66.3 77.3
65.7 58.0 59.4 67.1 67.3
76.0 71.5 72.4 79.4 79.6
Vehicle Noise: 79.0 77.8 74.1 73.7 80.8 81.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
264 569 1,225 2,640
274 590 1,271 2,739
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Haven Av.
Scenario: E
13,491
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,067 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
-2.64
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -18.17 1.46 -1.20 0.000 0.000
85.38 -11.58 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.8 66.5 64.7 61.7 69.1 69.5
63.1 74.1
62.5 54.8 56.1 63.9 64.0
72.8 68.2 69.1 76.1 76.3
Vehicle Noise: 75.2 74.0 70.0 70.0 77.1 77.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
149 322 694 1,495
155 333 718 1,546
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Haven Av.
Scenario: E+P
40,050
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,168 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
2.51 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 95.46%
82.2% 3.5% 14.3% 0.82%
70.8% 6.2% 23.0% 3.72%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -18.17 1.46 -1.20 0.000 0.000
85.38 -11.58 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.9 71.7 69.9 66.8 74.3 74.7
63.1 74.1
62.5 54.8 56.1 63.9 64.0
72.8 68.2 69.1 76.1 76.3
Vehicle Noise: 76.7 75.5 72.2 71.3 78.5 78.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
183 395 851 1,834
191 412 887 1,912
Friday, October 14, 2022
107
6029
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Haven Av.
Scenario: OY
18,453
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,460 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
-1.28
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -16.81 1.46 -1.20 0.000 0.000
85.38 -10.22 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.1 67.9 66.1 63.1 70.5 70.9
64.4 75.4
63.8 56.1 57.5 65.3 65.4
74.1 69.6 70.5 77.5 77.7
Vehicle Noise: 76.6 75.4 71.3 71.4 78.5 78.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
184 397 855 1,842
191 410 884 1,905
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Haven Av.
Scenario: OY+P
45,012
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,560 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
2.97 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 94.48%
82.2% 3.5% 14.3% 0.99%
70.8% 6.2% 23.0% 4.53%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -16.81 1.46 -1.20 0.000 0.000
85.38 -10.22 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.4 72.1 70.4 67.3 74.7 75.1
64.4 75.4
63.8 56.1 57.5 65.3 65.4
74.1 69.6 70.5 77.5 77.7
Vehicle Noise: 77.7 76.5 73.1 72.3 79.5 79.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
215 463 999 2,151
224 482 1,039 2,239
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Haven Av.
Scenario: HY
24,005
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,899 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
-0.14
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -15.67 1.46 -1.20 0.000 0.000
85.38 -9.08 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.3 69.0 67.2 64.2 71.6 72.0
65.6 76.6
65.0 57.3 58.6 66.4 66.5
75.3 70.8 71.6 78.6 78.8
Vehicle Noise: 77.8 76.5 72.5 72.5 79.6 79.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
219 473 1,019 2,195
227 489 1,054 2,270
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Ontario Ranch Rd.
Road Name: Haven Av.
Scenario: HY+P
50,564
7.91%
50.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,000 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 50.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 62 feet
REMEL Traffic Flow Distance
3.44 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 93.61%
82.2% 3.5% 14.3% 1.15%
70.8% 6.2% 23.0% 5.24%
1.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -15.67 1.46 -1.20 0.000 0.000
85.38 -9.08 1.46 -1.20 0.000 0.000
-4.65
-4.87
-5.43
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
39.547
39.323
39.345
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.9 72.6 70.8 67.8 75.2 75.6
65.6 76.6
65.0 57.3 58.6 66.4 66.5
75.3 70.8 71.6 78.6 78.8
Vehicle Noise: 78.6 77.4 73.9 73.3 80.4 80.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
248 534 1,151 2,481
258 556 1,197 2,579
Friday, October 14, 2022
108
6030
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Mill Creek Av.
Scenario: E
2,866
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 227 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 36 feet
REMEL Traffic Flow Distance
-8.91
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.28 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -24.44 1.31 -1.20 0.000 0.000
84.25 -17.85 1.31 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
40.460
40.241
40.262
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
59.6 58.3 56.6 53.5 61.0 61.4
55.1 66.5
54.5 46.8 48.1 55.9 56.1
65.2 60.7 61.6 68.6 68.8
Vehicle Noise: 67.6 66.3 62.2 62.4 69.5 69.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
41 87 188 406
42 90 195 420
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Mill Creek Av.
Scenario: E+P
9,207
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 728 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 36 feet
REMEL Traffic Flow Distance
-3.40
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 95.81%
82.2% 3.5% 14.3% 0.75%
70.8% 6.2% 23.0% 3.44%
1.28 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -24.44 1.31 -1.20 0.000 0.000
84.25 -17.85 1.31 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
40.460
40.241
40.262
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
65.1 63.9 62.1 59.0 66.5 66.9
55.1 66.5
54.5 46.8 48.1 55.9 56.1
65.2 60.7 61.6 68.6 68.8
Vehicle Noise: 69.1 67.8 64.5 63.6 70.8 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
50 107 231 498
52 112 241 519
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Mill Creek Av.
Scenario: OY
3,164
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 250 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 36 feet
REMEL Traffic Flow Distance
-8.48
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.28 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -24.01 1.31 -1.20 0.000 0.000
84.25 -17.42 1.31 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
40.460
40.241
40.262
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
60.1 58.8 57.0 54.0 61.4 61.8
55.5 66.9
54.9 47.2 48.6 56.4 56.5
65.7 61.1 62.0 69.0 69.2
Vehicle Noise: 68.0 66.8 62.7 62.8 69.9 70.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
43 93 201 434
45 97 208 448
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Mill Creek Av.
Scenario: OY+P
9,505
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 752 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 36 feet
REMEL Traffic Flow Distance
-3.28
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 95.52%
82.2% 3.5% 14.3% 0.81%
70.8% 6.2% 23.0% 3.68%
1.28 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -24.01 1.31 -1.20 0.000 0.000
84.25 -17.42 1.31 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
40.460
40.241
40.262
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
65.3 64.0 62.2 59.2 66.6 67.0
55.5 66.9
54.9 47.2 48.6 56.4 56.5
65.7 61.1 62.0 69.0 69.2
Vehicle Noise: 69.4 68.1 64.8 64.0 71.1 71.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
52 113 243 523
55 117 253 545
Friday, October 14, 2022
109
6031
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Mill Creek Av.
Scenario: HY
7,391
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 585 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 36 feet
REMEL Traffic Flow Distance
-4.80
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
1.28 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -20.33 1.31 -1.20 0.000 0.000
84.25 -13.74 1.31 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
40.460
40.241
40.262
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.7 62.5 60.7 57.6 65.1 65.5
59.2 70.6
58.6 50.9 52.3 60.0 60.2
69.4 64.8 65.7 72.7 72.9
Vehicle Noise: 71.7 70.5 66.4 66.5 73.6 73.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
76 165 354 764
79 170 366 789
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Mill Creek Av.
Scenario: HY+P
13,732
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,086 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 45 mph
Near/Far Lane Distance: 36 feet
REMEL Traffic Flow Distance
-1.81
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.75%
82.2% 3.5% 14.3% 1.30%
70.8% 6.2% 23.0% 5.95%
1.28 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
79.45 -20.33 1.31 -1.20 0.000 0.000
84.25 -13.74 1.31 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
68.46 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
40.460
40.241
40.262
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.7 65.5 63.7 60.6 68.1 68.5
59.2 70.6
58.6 50.9 52.3 60.0 60.2
69.4 64.8 65.7 72.7 72.9
Vehicle Noise: 72.3 71.1 67.4 67.0 74.2 74.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
83 179 387 833
86 186 401 864
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Milliken Av.
Scenario: E
19,818
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,568 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.38
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.92 0.61 -1.20 0.000 0.000
86.40 -10.32 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.8 68.5 66.7 63.7 71.1 71.5
64.9 75.5
64.3 56.6 57.9 65.7 65.8
74.2 69.7 70.6 77.6 77.7
Vehicle Noise: 76.8 75.6 71.6 71.6 78.7 78.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
227 489 1,054 2,271
235 507 1,091 2,351
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Milliken Av.
Scenario: E+P
33,876
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,680 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.18 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.28%
82.2% 3.5% 14.3% 1.55%
70.8% 6.2% 23.0% 7.17%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.52 0.61 -1.20 0.000 0.000
86.40 -9.87 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.3 71.1 69.3 66.2 73.7 74.1
65.3 75.9
64.7 57.0 58.3 66.1 66.2
74.7 70.1 71.0 78.0 78.2
Vehicle Noise: 77.8 76.5 72.9 72.4 79.6 79.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
261 562 1,211 2,608
271 583 1,257 2,707
Friday, October 14, 2022
110
6032
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Milliken Av.
Scenario: OY
22,416
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,773 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.85
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.38 0.61 -1.20 0.000 0.000
86.40 -9.79 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.3 69.0 67.3 64.2 71.6 72.0
65.4 76.0
64.8 57.1 58.5 66.2 66.4
74.7 70.2 71.1 78.1 78.3
Vehicle Noise: 77.3 76.1 72.1 72.1 79.2 79.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
247 531 1,145 2,466
255 550 1,185 2,552
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Milliken Av.
Scenario: OY+P
36,475
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,885 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.48 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.94%
82.2% 3.5% 14.3% 1.61%
70.8% 6.2% 23.0% 7.45%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.03 0.61 -1.20 0.000 0.000
86.40 -9.39 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.6 71.4 69.6 66.6 74.0 74.4
65.8 76.4
65.2 57.5 58.8 66.6 66.7
75.1 70.6 71.5 78.5 78.7
Vehicle Noise: 78.2 77.0 73.3 72.9 80.0 80.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
279 601 1,295 2,790
290 624 1,344 2,896
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Milliken Av.
Scenario: HY
53,343
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,219 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.92 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.62 0.61 -1.20 0.000 0.000
86.40 -6.02 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.1 72.8 71.0 68.0 75.4 75.8
69.2 79.8
68.6 60.9 62.2 70.0 70.1
78.5 74.0 74.9 81.9 82.0
Vehicle Noise: 81.1 79.9 75.9 75.9 83.0 83.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
440 947 2,040 4,395
455 980 2,112 4,549
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: n/o Riverside Dr.
Road Name: Milliken Av.
Scenario: HY+P
67,401
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 5,331 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
4.05 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.92%
82.2% 3.5% 14.3% 1.98%
70.8% 6.2% 23.0% 9.10%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.47 0.61 -1.20 0.000 0.000
86.40 -5.85 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
75.2 73.9 72.2 69.1 76.5 76.9
69.3 80.0
68.7 61.0 62.4 70.2 70.3
78.7 74.1 75.0 82.0 82.2
Vehicle Noise: 81.5 80.3 76.4 76.2 83.3 83.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
464 1,000 2,155 4,643
481 1,037 2,233 4,811
Friday, October 14, 2022
111
6033
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Milliken Av.
Scenario: E
18,436
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,458 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.70
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.23 0.61 -1.20 0.000 0.000
86.40 -10.64 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.5 68.2 66.4 63.4 70.8 71.2
64.6 75.2
64.0 56.3 57.6 65.4 65.5
73.9 69.4 70.3 77.2 77.4
Vehicle Noise: 76.5 75.3 71.3 71.3 78.4 78.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
216 466 1,005 2,165
224 483 1,040 2,240
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Milliken Av.
Scenario: E+P
28,604
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,263 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.39 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.32%
82.2% 3.5% 14.3% 1.72%
70.8% 6.2% 23.0% 7.96%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.81 0.61 -1.20 0.000 0.000
86.40 -10.15 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.6 70.3 68.5 65.5 72.9 73.3
65.0 75.7
64.4 56.7 58.0 65.8 66.0
74.4 69.8 70.7 77.7 77.9
Vehicle Noise: 77.3 76.1 72.4 72.0 79.2 79.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
245 528 1,138 2,451
254 548 1,180 2,542
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Milliken Av.
Scenario: OY
21,431
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,695 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.04
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.58 0.61 -1.20 0.000 0.000
86.40 -9.98 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.1 68.8 67.1 64.0 71.4 71.9
65.2 75.8
64.6 56.9 58.3 66.0 66.2
74.5 70.0 70.9 77.9 78.1
Vehicle Noise: 77.1 75.9 71.9 71.9 79.0 79.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
239 516 1,111 2,393
248 534 1,150 2,477
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Milliken Av.
Scenario: OY+P
31,599
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,499 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.81 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.96%
82.2% 3.5% 14.3% 1.79%
70.8% 6.2% 23.0% 8.25%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.21 0.61 -1.20 0.000 0.000
86.40 -9.56 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.0 70.7 68.9 65.9 73.3 73.7
65.6 76.2
65.0 57.3 58.6 66.4 66.6
75.0 70.4 71.3 78.3 78.5
Vehicle Noise: 77.9 76.7 72.9 72.6 79.7 80.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
267 575 1,238 2,667
277 596 1,284 2,765
Friday, October 14, 2022
112
6034
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Milliken Av.
Scenario: HY
41,531
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,285 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.83 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.71 0.61 -1.20 0.000 0.000
86.40 -7.11 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.0 71.7 69.9 66.9 74.3 74.7
68.1 78.7
67.5 59.8 61.1 68.9 69.1
77.4 72.9 73.8 80.8 81.0
Vehicle Noise: 80.0 78.8 74.8 74.8 81.9 82.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
372 801 1,727 3,720
385 829 1,787 3,850
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Riverside Dr.
Road Name: Milliken Av.
Scenario: HY+P
51,699
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,089 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.88 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.63%
82.2% 3.5% 14.3% 2.03%
70.8% 6.2% 23.0% 9.34%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.51 0.61 -1.20 0.000 0.000
86.40 -6.89 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.0 72.8 71.0 68.0 75.4 75.8
68.3 78.9
67.7 60.0 61.3 69.1 69.3
77.6 73.1 74.0 81.0 81.2
Vehicle Noise: 80.4 79.2 75.3 75.1 82.3 82.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
394 849 1,830 3,942
408 880 1,896 4,084
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Hamner Av.
Scenario: E
18,514
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,464 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.68
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.21 0.61 -1.20 0.000 0.000
86.40 -10.62 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.5 68.2 66.4 63.4 70.8 71.2
64.6 75.2
64.0 56.3 57.6 65.4 65.6
73.9 69.4 70.3 77.3 77.5
Vehicle Noise: 76.5 75.3 71.3 71.3 78.4 78.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
217 468 1,008 2,171
225 484 1,043 2,247
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Hamner Av.
Scenario: E+P
28,300
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,239 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.34 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.18%
82.2% 3.5% 14.3% 1.74%
70.8% 6.2% 23.0% 8.08%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.79 0.61 -1.20 0.000 0.000
86.40 -10.14 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.5 70.2 68.5 65.4 72.8 73.2
65.0 75.7
64.4 56.7 58.1 65.8 66.0
74.4 69.9 70.8 77.7 77.9
Vehicle Noise: 77.3 76.1 72.3 72.0 79.2 79.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
245 528 1,138 2,451
254 548 1,180 2,542
Friday, October 14, 2022
113
6035
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Hamner Av.
Scenario: OY
20,979
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,659 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.14
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.67 0.61 -1.20 0.000 0.000
86.40 -10.08 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.0 68.7 67.0 63.9 71.4 71.8
65.1 75.7
64.5 56.8 58.2 66.0 66.1
74.5 69.9 70.8 77.8 78.0
Vehicle Noise: 77.1 75.8 71.8 71.8 78.9 79.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
236 508 1,095 2,359
244 526 1,133 2,442
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Hamner Av.
Scenario: OY+P
30,765
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,434 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.69 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.89%
82.2% 3.5% 14.3% 1.80%
70.8% 6.2% 23.0% 8.31%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.30 0.61 -1.20 0.000 0.000
86.40 -9.65 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.9 70.6 68.8 65.8 73.2 73.6
65.5 76.2
64.9 57.2 58.6 66.3 66.5
74.9 70.3 71.2 78.2 78.4
Vehicle Noise: 77.8 76.6 72.8 72.5 79.6 79.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
263 566 1,220 2,629
273 587 1,265 2,726
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Hamner Av.
Scenario: HY
42,863
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,390 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.97 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.57 0.61 -1.20 0.000 0.000
86.40 -6.97 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.1 71.9 70.1 67.0 74.5 74.9
68.2 78.8
67.6 59.9 61.3 69.1 69.2
77.6 73.0 73.9 80.9 81.1
Vehicle Noise: 80.2 78.9 74.9 74.9 82.0 82.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
380 818 1,763 3,799
393 847 1,825 3,932
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Chino Av.
Road Name: Hamner Av.
Scenario: HY+P
52,650
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,165 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.96 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.49%
82.2% 3.5% 14.3% 2.06%
70.8% 6.2% 23.0% 9.45%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.38 0.61 -1.20 0.000 0.000
86.40 -6.76 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.1 72.8 71.1 68.0 75.4 75.9
68.4 79.0
67.8 60.1 61.5 69.2 69.4
77.8 73.2 74.1 81.1 81.3
Vehicle Noise: 80.5 79.3 75.4 75.3 82.4 82.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
401 865 1,863 4,015
416 896 1,931 4,159
Friday, October 14, 2022
114
6036
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Ontario Ranch Rd.
Road Name: Hamner Av.
Scenario: E
26,376
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,086 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.14
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.68 0.61 -1.20 0.000 0.000
86.40 -9.08 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.0 69.7 68.0 64.9 72.3 72.8
66.1 76.7
65.5 57.8 59.2 66.9 67.1
75.5 70.9 71.8 78.8 79.0
Vehicle Noise: 78.0 76.8 72.8 72.8 79.9 80.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
275 592 1,276 2,748
284 613 1,320 2,845
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Ontario Ranch Rd.
Road Name: Hamner Av.
Scenario: E+P
34,332
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,716 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.16 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.65%
82.2% 3.5% 14.3% 1.86%
70.8% 6.2% 23.0% 8.49%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.68 0.61 -1.20 0.000 0.000
86.40 -9.08 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.3 71.0 69.3 66.2 73.6 74.1
66.1 76.7
65.5 57.8 59.2 66.9 67.1
75.5 70.9 71.8 78.8 79.0
Vehicle Noise: 78.3 77.1 73.3 73.0 80.2 80.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
286 616 1,327 2,859
296 639 1,376 2,964
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Ontario Ranch Rd.
Road Name: Hamner Av.
Scenario: OY
29,827
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,359 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.39 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.14 0.61 -1.20 0.000 0.000
86.40 -8.55 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.6 70.3 68.5 65.5 72.9 73.3
66.7 77.3
66.0 58.3 59.7 67.5 67.6
76.0 71.4 72.3 79.3 79.5
Vehicle Noise: 78.6 77.4 73.4 73.3 80.4 80.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
298 643 1,385 2,983
309 665 1,433 3,088
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Ontario Ranch Rd.
Road Name: Hamner Av.
Scenario: OY+P
37,783
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,989 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.56 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.37%
82.2% 3.5% 14.3% 1.91%
70.8% 6.2% 23.0% 8.72%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.14 0.61 -1.20 0.000 0.000
86.40 -8.55 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.7 71.4 69.7 66.6 74.0 74.5
66.7 77.3
66.0 58.3 59.7 67.5 67.6
76.0 71.4 72.3 79.3 79.5
Vehicle Noise: 78.8 77.6 73.8 73.6 80.7 80.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
309 666 1,434 3,090
320 690 1,486 3,203
Friday, October 14, 2022
115
6037
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Ontario Ranch Rd.
Road Name: Hamner Av.
Scenario: HY
31,170
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,466 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
0.58 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.95 0.61 -1.20 0.000 0.000
86.40 -8.36 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.7 70.5 68.7 65.7 73.1 73.5
66.9 77.4
66.2 58.5 59.9 67.7 67.8
76.2 71.6 72.5 79.5 79.7
Vehicle Noise: 78.8 77.5 73.6 73.5 80.6 80.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
307 662 1,426 3,072
318 685 1,476 3,180
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: s/o Ontario Ranch Rd.
Road Name: Hamner Av.
Scenario: HY+P
39,126
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,095 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.70 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.27%
82.2% 3.5% 14.3% 1.93%
70.8% 6.2% 23.0% 8.80%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.95 0.61 -1.20 0.000 0.000
86.40 -8.36 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.9 71.6 69.8 66.8 74.2 74.6
66.9 77.4
66.2 58.5 59.9 67.7 67.8
76.2 71.6 72.5 79.5 79.7
Vehicle Noise: 79.0 77.8 74.0 73.7 80.9 81.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
318 684 1,475 3,177
329 709 1,528 3,293
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Riverside Dr.
Scenario: E
15,880
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,256 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.93
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -17.47 0.61 -1.20 0.000 0.000
85.38 -10.87 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
67.7 66.4 64.6 61.6 69.0 69.4
62.9 73.9
62.3 54.6 56.0 63.8 63.9
72.6 68.1 69.0 76.0 76.2
Vehicle Noise: 75.1 73.9 69.8 69.9 77.0 77.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
176 378 815 1,756
182 391 843 1,816
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Riverside Dr.
Scenario: E+P
17,898
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,416 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.34
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.05%
82.2% 3.5% 14.3% 2.15%
70.8% 6.2% 23.0% 9.80%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -17.47 0.61 -1.20 0.000 0.000
85.38 -10.87 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.2 67.0 65.2 62.2 69.6 70.0
62.9 73.9
62.3 54.6 56.0 63.8 63.9
72.6 68.1 69.0 76.0 76.2
Vehicle Noise: 75.2 74.0 70.0 70.0 77.1 77.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
178 384 827 1,783
185 398 857 1,845
Friday, October 14, 2022
116
6038
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Riverside Dr.
Scenario: OY
18,998
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,503 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.15
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -16.69 0.61 -1.20 0.000 0.000
85.38 -10.09 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.4 67.2 65.4 62.3 69.8 70.2
63.7 74.7
63.1 55.4 56.8 64.5 64.7
73.4 68.9 69.8 76.8 77.0
Vehicle Noise: 75.9 74.7 70.6 70.7 77.8 78.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
198 426 918 1,978
205 441 950 2,047
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Riverside Dr.
Scenario: OY+P
21,016
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,662 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.65
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 87.83%
82.2% 3.5% 14.3% 2.19%
70.8% 6.2% 23.0% 9.99%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -16.69 0.61 -1.20 0.000 0.000
85.38 -10.09 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.9 67.7 65.9 62.8 70.3 70.7
63.7 74.7
63.1 55.4 56.8 64.5 64.7
73.4 68.9 69.8 76.8 77.0
Vehicle Noise: 76.0 74.8 70.8 70.8 77.9 78.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
200 432 930 2,004
207 447 963 2,074
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Riverside Dr.
Scenario: HY
32,988
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,609 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.24 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -14.29 0.61 -1.20 0.000 0.000
85.38 -7.70 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.8 69.6 67.8 64.7 72.2 72.6
66.1 77.1
65.5 57.8 59.2 66.9 67.1
75.8 71.3 72.2 79.2 79.4
Vehicle Noise: 78.3 77.1 73.0 73.1 80.2 80.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
286 616 1,327 2,858
296 637 1,372 2,957
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Riverside Dr.
Scenario: HY+P
35,006
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,769 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.54 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 87.31%
82.2% 3.5% 14.3% 2.28%
70.8% 6.2% 23.0% 10.41%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -14.29 0.61 -1.20 0.000 0.000
85.38 -7.70 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.1 69.8 68.1 65.0 72.5 72.9
66.1 77.1
65.5 57.8 59.2 66.9 67.1
75.8 71.3 72.2 79.2 79.4
Vehicle Noise: 78.3 77.1 73.1 73.1 80.2 80.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
288 620 1,337 2,879
298 642 1,383 2,980
Friday, October 14, 2022
117
6039
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Milliken Av.
Road Name: Riverside Dr.
Scenario: E
9,308
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 736 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-4.25
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -19.79 0.61 -1.20 0.000 0.000
85.38 -13.19 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
65.3 64.1 62.3 59.2 66.7 67.1
60.6 71.6
60.0 52.3 53.7 61.4 61.6
70.3 65.8 66.7 73.7 73.9
Vehicle Noise: 72.8 71.6 67.5 67.6 74.7 74.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
123 265 571 1,230
127 274 590 1,272
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Milliken Av.
Road Name: Riverside Dr.
Scenario: E+P
16,275
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,287 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-1.55
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.30%
82.2% 3.5% 14.3% 1.38%
70.8% 6.2% 23.0% 6.32%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -19.79 0.61 -1.20 0.000 0.000
85.38 -13.19 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
68.0 66.8 65.0 61.9 69.4 69.8
60.6 71.6
60.0 52.3 53.7 61.4 61.6
70.3 65.8 66.7 73.7 73.9
Vehicle Noise: 73.4 72.2 68.5 68.1 75.2 75.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
134 289 622 1,339
139 300 645 1,390
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Milliken Av.
Road Name: Riverside Dr.
Scenario: OY
13,501
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,068 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-2.64
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -18.17 0.61 -1.20 0.000 0.000
85.38 -11.58 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
66.9 65.7 63.9 60.9 68.3 68.7
62.2 73.2
61.6 53.9 55.3 63.1 63.2
71.9 67.4 68.3 75.3 75.5
Vehicle Noise: 74.4 73.2 69.1 69.2 76.3 76.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
158 339 731 1,576
163 351 757 1,630
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Milliken Av.
Road Name: Riverside Dr.
Scenario: OY+P
20,468
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,619 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
-0.61
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.12%
82.2% 3.5% 14.3% 1.60%
70.8% 6.2% 23.0% 7.29%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -18.17 0.61 -1.20 0.000 0.000
85.38 -11.58 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
69.0 67.7 65.9 62.9 70.3 70.7
62.2 73.2
61.6 53.9 55.3 63.1 63.2
71.9 67.4 68.3 75.3 75.5
Vehicle Noise: 74.8 73.6 69.9 69.6 76.7 76.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
167 360 777 1,673
174 374 805 1,735
Friday, October 14, 2022
118
6040
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Milliken Av.
Road Name: Riverside Dr.
Scenario: HY
36,188
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,862 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
1.64 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -13.89 0.61 -1.20 0.000 0.000
85.38 -7.30 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.2 70.0 68.2 65.1 72.6 73.0
66.5 77.5
65.9 58.2 59.6 67.3 67.5
76.2 71.7 72.6 79.6 79.8
Vehicle Noise: 78.7 77.5 73.4 73.5 80.6 80.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
304 655 1,411 3,040
314 678 1,460 3,145
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Milliken Av.
Road Name: Riverside Dr.
Scenario: HY+P
43,155
7.91%
60.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,414 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 60.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 50 mph
Near/Far Lane Distance: 80 feet
REMEL Traffic Flow Distance
2.52 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 88.71%
82.2% 3.5% 14.3% 2.03%
70.8% 6.2% 23.0% 9.26%
0.58 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
81.00 -13.89 0.61 -1.20 0.000 0.000
85.38 -7.30 0.61 -1.20 0.000 0.000
-4.69
-4.88
-5.34
Medium Trucks:
Heavy Trucks:
Autos:
70.20 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
45.000
44.803
44.822
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.1 70.8 69.1 66.0 73.4 73.8
66.5 77.5
65.9 58.2 59.6 67.3 67.5
76.2 71.7 72.6 79.6 79.8
Vehicle Noise: 78.9 77.6 73.7 73.6 80.7 80.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
311 670 1,444 3,111
322 694 1,495 3,221
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Chino Av.
Scenario: E
5,409
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 428 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 12 feet
REMEL Traffic Flow Distance
-5.64
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.75 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -21.17 0.78 -1.20 0.000 0.000
82.99 -14.58 0.78 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
43.875
43.673
43.692
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
60.4 59.1 57.4 54.3 61.7 62.2
56.1 68.0
55.5 47.8 49.2 56.9 57.1
66.7 62.2 63.1 70.1 70.3
Vehicle Noise: 68.9 67.7 63.5 63.8 70.8 71.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
50 108 233 501
52 112 240 518
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Chino Av.
Scenario: E+P
8,054
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 637 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 12 feet
REMEL Traffic Flow Distance
-3.70
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.95%
82.2% 3.5% 14.3% 1.63%
70.8% 6.2% 23.0% 7.42%
0.75 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -21.17 0.78 -1.20 0.000 0.000
82.99 -14.58 0.78 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
43.875
43.673
43.692
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
62.4 61.1 59.3 56.3 63.7 64.1
56.1 68.0
55.5 47.8 49.2 56.9 57.1
66.7 62.2 63.1 70.1 70.3
Vehicle Noise: 69.3 68.0 64.1 64.0 71.1 71.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
52 113 243 524
54 117 252 542
Friday, October 14, 2022
119
6041
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Chino Av.
Scenario: OY
9,529
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 754 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 12 feet
REMEL Traffic Flow Distance
-3.18
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.75 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -18.72 0.78 -1.20 0.000 0.000
82.99 -12.12 0.78 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
43.875
43.673
43.692
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
62.9 61.6 59.8 56.8 64.2 64.6
58.6 70.4
58.0 50.2 51.6 59.4 59.5
69.2 64.6 65.5 72.5 72.7
Vehicle Noise: 71.4 70.1 66.0 66.2 73.3 73.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
73 157 339 731
76 163 350 755
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Chino Av.
Scenario: OY+P
12,173
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 963 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 12 feet
REMEL Traffic Flow Distance
-1.97
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.46%
82.2% 3.5% 14.3% 1.89%
70.8% 6.2% 23.0% 8.65%
0.75 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -18.72 0.78 -1.20 0.000 0.000
82.99 -12.12 0.78 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
43.875
43.673
43.692
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.1 62.8 61.0 58.0 65.4 65.8
58.6 70.4
58.0 50.2 51.6 59.4 59.5
69.2 64.6 65.5 72.5 72.7
Vehicle Noise: 71.6 70.3 66.3 66.4 73.5 73.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
75 162 348 750
78 167 360 776
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Chino Av.
Scenario: HY
11,003
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 870 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 12 feet
REMEL Traffic Flow Distance
-2.56
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
0.75 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -18.09 0.78 -1.20 0.000 0.000
82.99 -11.50 0.78 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
43.875
43.673
43.692
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
63.5 62.2 60.5 57.4 64.8 65.2
59.2 71.1
58.6 50.9 52.2 60.0 60.2
69.8 65.3 66.2 73.2 73.3
Vehicle Noise: 72.0 70.8 66.6 66.9 73.9 74.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
80 173 373 804
83 179 386 831
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Chino Av.
Scenario: HY+P
13,647
7.91%
44.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,080 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 44.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 40 mph
Near/Far Lane Distance: 12 feet
REMEL Traffic Flow Distance
-1.49
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.14%
82.2% 3.5% 14.3% 1.95%
70.8% 6.2% 23.0% 8.91%
0.75 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
77.72 -18.09 0.78 -1.20 0.000 0.000
82.99 -11.50 0.78 -1.20 0.000 0.000
-4.61
-4.87
-5.50
Medium Trucks:
Heavy Trucks:
Autos:
66.51 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
43.875
43.673
43.692
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
64.6 63.3 61.5 58.5 65.9 66.3
59.2 71.1
58.6 50.9 52.2 60.0 60.2
69.8 65.3 66.2 73.2 73.3
Vehicle Noise: 72.2 70.9 66.9 67.0 74.1 74.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
82 177 382 823
85 183 395 851
Friday, October 14, 2022
120
6042
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: E
13,582
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,074 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-3.03
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -18.56 2.47 -1.20 0.000 0.000
86.40 -11.97 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.0 68.7 66.9 63.9 71.3 71.7
65.1 75.7
64.5 56.8 58.1 65.9 66.1
74.4 69.9 70.8 77.8 78.0
Vehicle Noise: 77.0 75.8 71.8 71.8 78.9 79.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
329 708 1,525 3,286
340 733 1,578 3,401
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: E+P
20,888
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,652 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-0.97
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.42%
82.2% 3.5% 14.3% 1.70%
70.8% 6.2% 23.0% 7.87%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -18.21 2.47 -1.20 0.000 0.000
86.40 -11.57 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.0 70.8 69.0 65.9 73.4 73.8
65.5 76.1
64.8 57.1 58.5 66.3 66.4
74.8 70.3 71.2 78.2 78.4
Vehicle Noise: 77.8 76.6 72.8 72.5 79.6 79.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
368 792 1,707 3,678
382 822 1,771 3,815
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: OY
16,875
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,335 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-2.08
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.62 2.47 -1.20 0.000 0.000
86.40 -11.02 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.9 69.6 67.9 64.8 72.2 72.7
66.1 76.6
65.4 57.7 59.1 66.9 67.0
75.4 70.8 71.7 78.7 78.9
Vehicle Noise: 78.0 76.7 72.7 72.7 79.8 80.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
380 818 1,763 3,797
393 847 1,824 3,930
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: OY+P
24,182
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,913 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-0.36
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.89%
82.2% 3.5% 14.3% 1.80%
70.8% 6.2% 23.0% 8.31%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.33 2.47 -1.20 0.000 0.000
86.40 -10.70 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.6 71.4 69.6 66.6 74.0 74.4
66.3 77.0
65.7 58.0 59.4 67.2 67.3
75.7 71.2 72.0 79.0 79.2
Vehicle Noise: 78.6 77.4 73.6 73.3 80.4 80.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
416 897 1,933 4,165
432 930 2,004 4,318
Friday, October 14, 2022
121
6043
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: HY
18,501
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,463 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-1.68
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.22 2.47 -1.20 0.000 0.000
86.40 -10.62 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.3 70.0 68.3 65.2 72.6 73.1
66.5 77.0
65.8 58.1 59.5 67.3 67.4
75.8 71.2 72.1 79.1 79.3
Vehicle Noise: 78.4 77.1 73.1 73.1 80.2 80.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
404 870 1,874 4,037
418 900 1,940 4,179
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: HY+P
25,808
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,041 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-0.08
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.68%
82.2% 3.5% 14.3% 1.84%
70.8% 6.2% 23.0% 8.48%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.96 2.47 -1.20 0.000 0.000
86.40 -10.33 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.9 71.6 69.9 66.8 74.2 74.7
66.7 77.3
66.1 58.4 59.7 67.5 67.7
76.1 71.5 72.4 79.4 79.6
Vehicle Noise: 78.9 77.7 73.9 73.7 80.8 81.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
439 947 2,040 4,394
456 982 2,115 4,556
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: E
16,280
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,288 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-2.24
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.77 2.47 -1.20 0.000 0.000
86.40 -11.18 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
70.8 69.5 67.7 64.7 72.1 72.5
65.9 76.5
65.3 57.6 58.9 66.7 66.9
75.2 70.7 71.6 78.6 78.8
Vehicle Noise: 77.8 76.6 72.6 72.6 79.7 79.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
371 799 1,721 3,708
384 827 1,781 3,837
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: E+P
33,653
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,662 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
1.23 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.98%
82.2% 3.5% 14.3% 1.25%
70.8% 6.2% 23.0% 5.77%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.48 2.47 -1.20 0.000 0.000
86.40 -10.84 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.2 73.0 71.2 68.1 75.6 76.0
66.2 76.8
65.6 57.9 59.2 67.0 67.1
75.5 71.0 71.9 78.9 79.1
Vehicle Noise: 79.0 77.7 74.2 73.6 80.7 81.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
437 941 2,027 4,368
454 978 2,108 4,541
Friday, October 14, 2022
122
6044
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: OY
19,855
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,570 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-1.38
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.91 2.47 -1.20 0.000 0.000
86.40 -10.32 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.6 70.3 68.6 65.5 72.9 73.4
66.8 77.3
66.1 58.4 59.8 67.6 67.7
76.1 71.5 72.4 79.4 79.6
Vehicle Noise: 78.7 77.4 73.5 73.4 80.5 80.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
423 912 1,964 4,232
438 944 2,033 4,380
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: OY+P
37,228
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,945 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
1.64 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.36%
82.2% 3.5% 14.3% 1.36%
70.8% 6.2% 23.0% 6.28%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.67 2.47 -1.20 0.000 0.000
86.40 -10.04 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.6 73.4 71.6 68.5 76.0 76.4
67.0 77.6
66.4 58.7 60.0 67.8 68.0
76.4 71.8 72.7 79.7 79.9
Vehicle Noise: 79.6 78.4 74.8 74.3 81.4 81.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
485 1,046 2,253 4,854
504 1,087 2,341 5,044
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: HY
19,774
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,564 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-1.39
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.93 2.47 -1.20 0.000 0.000
86.40 -10.33 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.6 70.3 68.6 65.5 72.9 73.3
66.7 77.3
66.1 58.4 59.8 67.6 67.7
76.1 71.5 72.4 79.4 79.6
Vehicle Noise: 78.6 77.4 73.4 73.4 80.5 80.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
422 909 1,959 4,221
437 941 2,028 4,368
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Archibald Av.
Road Name: Ontario Ranch Rd.
Scenario: HY+P
37,147
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,938 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
1.63 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.37%
82.2% 3.5% 14.3% 1.36%
70.8% 6.2% 23.0% 6.27%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.69 2.47 -1.20 0.000 0.000
86.40 -10.06 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.6 73.4 71.6 68.5 76.0 76.4
67.0 77.6
66.4 58.7 60.0 67.8 67.9
76.3 71.8 72.7 79.7 79.9
Vehicle Noise: 79.6 78.4 74.8 74.3 81.4 81.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
484 1,044 2,248 4,844
503 1,084 2,336 5,032
Friday, October 14, 2022
123
6045
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: E
18,294
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,447 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-1.73
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.27 2.47 -1.20 0.000 0.000
86.40 -10.67 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
71.3 70.0 68.2 65.2 72.6 73.0
66.4 77.0
65.8 58.1 59.4 67.2 67.4
75.7 71.2 72.1 79.1 79.3
Vehicle Noise: 78.3 77.1 73.1 73.1 80.2 80.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
401 863 1,860 4,007
415 894 1,925 4,148
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: E+P
39,277
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,107 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
1.91 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 93.29%
82.2% 3.5% 14.3% 1.20%
70.8% 6.2% 23.0% 5.51%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -17.00 2.47 -1.20 0.000 0.000
86.40 -10.37 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.9 73.6 71.9 68.8 76.2 76.6
66.7 77.3
66.0 58.3 59.7 67.5 67.6
76.0 71.5 72.4 79.4 79.6
Vehicle Noise: 79.5 78.3 74.8 74.1 81.3 81.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
474 1,022 2,202 4,743
493 1,063 2,290 4,933
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: OY
22,078
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,746 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-0.92
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.45 2.47 -1.20 0.000 0.000
86.40 -9.86 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.1 70.8 69.0 66.0 73.4 73.8
67.2 77.8
66.6 58.9 60.3 68.0 68.2
76.5 72.0 72.9 79.9 80.1
Vehicle Noise: 79.1 77.9 73.9 73.9 81.0 81.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
454 979 2,108 4,542
470 1,013 2,182 4,701
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: OY+P
43,061
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,406 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
2.28 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.70%
82.2% 3.5% 14.3% 1.30%
70.8% 6.2% 23.0% 6.00%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.23 2.47 -1.20 0.000 0.000
86.40 -9.61 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
75.3 74.0 72.2 69.2 76.6 77.0
67.4 78.1
66.8 59.1 60.5 68.3 68.4
76.8 72.2 73.1 80.1 80.3
Vehicle Noise: 80.1 78.9 75.4 74.8 81.9 82.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
524 1,129 2,431 5,238
544 1,173 2,527 5,444
Friday, October 14, 2022
124
6046
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: HY
52,058
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,118 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
2.81 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.72 2.47 -1.20 0.000 0.000
86.40 -6.13 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
75.8 74.5 72.8 69.7 77.1 77.5
71.0 81.5
70.3 62.6 64.0 71.8 71.9
80.3 75.7 76.6 83.6 83.8
Vehicle Noise: 82.9 81.6 77.6 77.6 84.7 84.9
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
805 1,734 3,735 8,047
833 1,794 3,866 8,329
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: HY+P
73,041
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 5,778 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
4.46 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.17%
82.2% 3.5% 14.3% 1.76%
70.8% 6.2% 23.0% 8.07%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.63 2.47 -1.20 0.000 0.000
86.40 -6.02 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
77.5 76.2 74.4 71.4 78.8 79.2
71.0 81.6
70.4 62.7 64.1 71.9 72.0
80.4 75.8 76.7 83.7 83.9
Vehicle Noise: 83.3 82.1 78.3 78.0 85.1 85.4
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
858 1,849 3,983 8,581
890 1,917 4,130 8,899
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: E
23,755
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,879 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-0.60
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.13 2.47 -1.20 0.000 0.000
86.40 -9.54 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.4 71.1 69.4 66.3 73.7 74.1
67.5 78.1
66.9 59.2 60.6 68.4 68.5
76.9 72.3 73.2 80.2 80.4
Vehicle Noise: 79.4 78.2 74.2 74.2 81.3 81.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
477 1,028 2,214 4,770
494 1,064 2,291 4,937
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: E+P
49,864
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,944 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
2.95 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 93.24%
82.2% 3.5% 14.3% 1.21%
70.8% 6.2% 23.0% 5.55%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.93 2.47 -1.20 0.000 0.000
86.40 -9.30 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
75.9 74.7 72.9 69.9 77.3 77.7
67.7 78.4
67.1 59.4 60.8 68.6 68.7
77.1 72.5 73.4 80.4 80.6
Vehicle Noise: 80.6 79.3 75.8 75.2 82.3 82.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
558 1,202 2,590 5,579
580 1,250 2,693 5,802
Friday, October 14, 2022
125
6047
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: OY
27,304
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,160 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
0.01 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.53 2.47 -1.20 0.000 0.000
86.40 -8.93 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.0 71.7 70.0 66.9 74.3 74.7
68.1 78.7
67.5 59.8 61.2 69.0 69.1
77.5 72.9 73.8 80.8 81.0
Vehicle Noise: 80.0 78.8 74.8 74.8 81.9 82.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
523 1,128 2,429 5,234
542 1,167 2,514 5,417
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: OY+P
53,412
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,225 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
3.22 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.79%
82.2% 3.5% 14.3% 1.29%
70.8% 6.2% 23.0% 5.92%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.35 2.47 -1.20 0.000 0.000
86.40 -8.73 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
76.2 74.9 73.2 70.1 77.6 78.0
68.3 78.9
67.7 60.0 61.4 69.1 69.3
77.7 73.1 74.0 81.0 81.2
Vehicle Noise: 81.0 79.8 76.3 75.7 82.8 83.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
601 1,295 2,790 6,010
625 1,346 2,900 6,247
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: HY
41,417
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,276 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
1.82 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.72 2.47 -1.20 0.000 0.000
86.40 -7.12 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.8 73.5 71.8 68.7 76.1 76.6
70.0 80.5
69.3 61.6 63.0 70.8 70.9
79.3 74.7 75.6 82.6 82.8
Vehicle Noise: 81.9 80.6 76.6 76.6 83.7 84.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
691 1,489 3,207 6,909
715 1,541 3,319 7,151
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Haven Av.
Road Name: Ontario Ranch Rd.
Scenario: HY+P
67,526
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 5,341 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
4.18 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.49%
82.2% 3.5% 14.3% 1.52%
70.8% 6.2% 23.0% 6.99%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.60 2.47 -1.20 0.000 0.000
86.40 -6.99 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
77.2 75.9 74.1 71.1 78.5 78.9
70.1 80.7
69.4 61.7 63.1 70.9 71.0
79.4 74.9 75.8 82.8 82.9
Vehicle Noise: 82.5 81.3 77.6 77.2 84.3 84.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
759 1,636 3,524 7,593
788 1,698 3,659 7,883
Friday, October 14, 2022
126
6048
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: E
22,522
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 1,781 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
-0.83
VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -16.36 2.47 -1.20 0.000 0.000
86.40 -9.77 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
72.2 70.9 69.1 66.1 73.5 73.9
67.3 77.9
66.7 59.0 60.3 68.1 68.3
76.6 72.1 73.0 80.0 80.2
Vehicle Noise: 79.2 78.0 74.0 74.0 81.1 81.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
460 992 2,137 4,603
476 1,026 2,211 4,764
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: E+P
54,967
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,348 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
3.36 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 93.13%
82.2% 3.5% 14.3% 1.21%
70.8% 6.2% 23.0% 5.66%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.51 2.47 -1.20 0.000 0.000
86.40 -8.80 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
76.4 75.1 73.3 70.3 77.7 78.1
68.2 78.9
67.5 59.8 61.2 69.0 69.1
77.6 73.1 73.9 80.9 81.1
Vehicle Noise: 81.0 79.8 76.3 75.7 82.8 83.1
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
600 1,293 2,786 6,003
624 1,345 2,897 6,242
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: OY
33,350
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,638 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
0.88 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.66 2.47 -1.20 0.000 0.000
86.40 -8.06 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.9 72.6 70.8 67.8 75.2 75.6
69.0 79.6
68.4 60.7 62.0 69.8 70.0
78.3 73.8 74.7 81.7 81.9
Vehicle Noise: 80.9 79.7 75.7 75.7 82.8 83.0
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
598 1,288 2,776 5,980
619 1,333 2,873 6,189
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: OY+P
65,795
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 5,204 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
4.09 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 92.04%
82.2% 3.5% 14.3% 1.41%
70.8% 6.2% 23.0% 6.55%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.06 2.47 -1.20 0.000 0.000
86.40 -7.38 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
77.1 75.8 74.1 71.0 78.4 78.8
69.6 80.3
69.0 61.3 62.6 70.4 70.6
79.0 74.5 75.4 82.4 82.5
Vehicle Noise: 82.2 81.0 77.4 76.9 84.0 84.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
723 1,558 3,358 7,234
751 1,619 3,488 7,514
Friday, October 14, 2022
127
6049
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: HY
45,327
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,585 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
2.21 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.33 2.47 -1.20 0.000 0.000
86.40 -6.73 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
75.2 73.9 72.2 69.1 76.5 76.9
70.3 80.9
69.7 62.0 63.4 71.2 71.3
79.7 75.1 76.0 83.0 83.2
Vehicle Noise: 82.3 81.0 77.0 77.0 84.1 84.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
734 1,581 3,406 7,338
759 1,636 3,525 7,594
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: w/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: HY+P
77,772
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 6,152 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
4.78 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.20%
82.2% 3.5% 14.3% 1.56%
70.8% 6.2% 23.0% 7.24%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.88 2.47 -1.20 0.000 0.000
86.40 -6.22 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
77.8 76.5 74.7 71.7 79.1 79.5
70.8 81.4
70.2 62.5 63.8 71.6 71.7
80.2 75.6 76.5 83.5 83.7
Vehicle Noise: 83.3 82.0 78.3 77.9 85.1 85.3
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
848 1,828 3,938 8,483
880 1,897 4,087 8,805
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: E
27,822
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 2,201 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
0.09 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -15.45 2.47 -1.20 0.000 0.000
86.40 -8.85 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
73.1 71.8 70.0 67.0 74.4 74.8
68.2 78.8
67.6 59.9 61.3 69.0 69.2
77.5 73.0 73.9 80.9 81.1
Vehicle Noise: 80.1 78.9 74.9 74.9 82.0 82.2
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
530 1,142 2,460 5,300
549 1,182 2,546 5,485
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: E+P
51,979
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,112 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
3.04 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 91.47%
82.2% 3.5% 14.3% 1.51%
70.8% 6.2% 23.0% 7.02%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -14.79 2.47 -1.20 0.000 0.000
86.40 -8.10 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
76.0 74.8 73.0 70.0 77.4 77.8
68.9 79.6
68.3 60.6 61.9 69.7 69.8
78.3 73.7 74.6 81.6 81.8
Vehicle Noise: 81.4 80.2 76.5 76.1 83.2 83.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
639 1,376 2,965 6,389
663 1,429 3,079 6,632
Friday, October 14, 2022
128
6050
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: OY
38,968
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,082 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
1.55 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.98 2.47 -1.20 0.000 0.000
86.40 -7.39 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
74.6 73.3 71.5 68.5 75.9 76.3
69.7 80.3
69.1 61.4 62.7 70.5 70.6
79.0 74.5 75.4 82.4 82.5
Vehicle Noise: 81.6 80.4 76.4 76.4 83.5 83.7
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
663 1,429 3,079 6,634
687 1,479 3,187 6,866
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: OY+P
63,124
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 4,993 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
3.85 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 90.60%
82.2% 3.5% 14.3% 1.67%
70.8% 6.2% 23.0% 7.73%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -13.50 2.47 -1.20 0.000 0.000
86.40 -6.84 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
76.8 75.6 73.8 70.8 78.2 78.6
70.2 80.8
69.5 61.8 63.2 71.0 71.1
79.5 75.0 75.9 82.9 83.1
Vehicle Noise: 82.5 81.3 77.6 77.2 84.4 84.6
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
762 1,642 3,537 7,620
791 1,703 3,669 7,905
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: HY
50,098
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 3,963 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
2.64 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 86.53%
82.2% 3.5% 14.3% 2.42%
70.8% 6.2% 23.0% 11.05%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.89 2.47 -1.20 0.000 0.000
86.40 -6.30 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
75.6 74.4 72.6 69.6 77.0 77.4
70.8 81.4
70.2 62.5 63.8 71.6 71.7
80.1 75.6 76.4 83.4 83.6
Vehicle Noise: 82.7 81.5 77.5 77.4 84.6 84.8
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
784 1,690 3,641 7,844
812 1,749 3,768 8,118
Friday, October 14, 2022
FHWA-RD-77-108 HIGHWAY NOISE PREDICTION MODEL (9/12/2021)
SITE SPECIFIC INPUT DATA
Project Name: Rich Haven Specific Plan
Job Number: 14822
Road Segment: e/o Hamner Av.
Road Name: Ontario Ranch Rd.
Scenario: HY+P
74,255
7.91%
84.0 NOISE MODEL INPUTS
Average Daily Traffic (Adt):
Peak Hour Percentage:
Peak Hour Volume: 5,874 vehicles
Centerline Dist. to Barrier:
Centerline Dist. to Observer: 84.0
Highway Data
feet
feet
vehicles
Road Elevation: 0.0
Road Grade: 0.0%
Pad Elevation: 0.0
Site Data
Site Conditions (Hard = 10, Soft = 15)
Medium Trucks (2 Axles): 15
Heavy Trucks (3+ Axles): 15
Autos: 15
Vehicle Mix
feet
feet Lane Equivalent Distance (in feet)
Barrier Height: 0.0
Observer Height (Above Pad): 5.0 feet
feet
Vehicle Speed: 55 mph
Near/Far Lane Distance: 154 feet
REMEL Traffic Flow Distance
4.52 VehicleType Day Evening Night Daily
Medium Trucks:
Heavy Trucks:
Autos: 70.7% 11.8% 17.5% 89.99%
82.2% 3.5% 14.3% 1.78%
70.8% 6.2% 23.0% 8.23%
2.42 Finite Road
-1.20
Left View: -90.0
Right View: 90.0
degrees
degrees
Barrier Atten
FHWA Noise Model Calculations
Barrier Distance to Observer: 0.0 feet
Barrier Type (0-Wall, 1-Berm): 0.0
0.000 0.000
Fresnel Berm Atten
Medium Trucks:
Heavy Trucks:
Autos:
VehicleType
82.40 -12.51 2.47 -1.20 0.000 0.000
86.40 -5.87 2.47 -1.20 0.000 0.000
-4.75
-4.88
-5.21
Medium Trucks:
Heavy Trucks:
Autos:
71.78 Noise Source Elevations (in feet)
Medium Trucks:
Heavy Trucks:
Autos: 0.000
2.297
8.004
33.941
33.679
33.705
Grade Adjustment: 0.0
Unmitigated Noise Levels (without Topo and barrier attenuation) Medium Trucks:
Heavy Trucks:
Autos:
VehicleType Leq Peak Hour Leq Day Leq Evening Leq Night Ldn CNEL
77.5 76.2 74.5 71.4 78.8 79.3
71.2 81.8
70.5 62.8 64.2 72.0 72.1
80.5 76.0 76.9 83.9 84.1
Vehicle Noise: 83.4 82.2 78.4 78.1 85.3 85.5
Centerline Distance to Noise Contour (in feet)
CNEL:
Ldn:
70 dBA 65 dBA 60 dBA 55 dBA
876 1,887 4,065 8,758
908 1,956 4,215 9,081
Friday, October 14, 2022
129
6051
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
130
6052
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
APPENDIX 10.1:
CADNAAOPERATIONAL NOISE MODEL INPUTS
131
6053
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
132
6054
14822 - Rich Haven Specific Plan
CadnaA Noise Prediction Model: 14822-02A.cna
Date: 17.10.22
Analyst: B. Lawson
Calculation Configuration
Configuration
Parameter Value
General
Max. Error (dB) 0.00
Max. Search Radius (#(Unit,LEN)) 2000.01
Min. Dist Src to Rcvr 0.00
Partition
Raster Factor 0.50
Max. Length of Section (#(Unit,LEN)) 999.99
Min. Length of Section (#(Unit,LEN)) 1.01
Min. Length of Section (%) 0.00
Proj. Line Sources On
Proj. Area Sources On
Ref. Time
Reference Time Day (min) 960.00
Reference Time Night (min) 480.00
Daytime Penalty (dB) 0.00
Recr. Time Penalty (dB) 5.00
Night-time Penalty (dB) 10.00
DTM
Standard Height (m) 0.00
Model of Terrain Triangulation
Reflection
max. Order of Reflection 2
Search Radius Src 100.00
Search Radius Rcvr 100.00
Max. Distance Source - Rcvr 1000.00 1000.00
Min. Distance Rvcr - Reflector 1.00 1.00
Min. Distance Source - Reflector 0.10
Industrial (ISO 9613)
Lateral Diffraction some Obj
Obst. within Area Src do not shield On
Screening Incl. Ground Att. over Barrier
Dz with limit (20/25)
Barrier Coefficients C1,2,3 3.0 20.0 0.0
Temperature (#(Unit,TEMP)) 10
rel. Humidity (%) 70
Ground Absorption G 0.50
Wind Speed for Dir. (#(Unit,SPEED)) 3.0
Roads (TNM)
Railways (FTA/FRA)
Aircraft (???)
Strictly acc. to AzB
Receiver Noise Levels
Name M. ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) (ft) (ft) (ft) (ft) RECEIVERS R1 44.9 44.8 51.5 65.0 45.0 0.0 5.00 a 6161938.34 2315328.19 5.00 RECEIVERS R2 44.8 44.7 51.4 65.0 45.0 0.0 5.00 a 6162735.95 2314875.32 5.00 RECEIVERS R3 45.9 44.5 51.2 65.0 45.0 0.0 5.00 a 6163483.69 2310238.26 5.00 RECEIVERS R4 42.8 42.5 49.2 65.0 45.0 0.0 5.00 a 6162048.86 2308936.45 5.00 RECEIVERS R5 43.0 42.4 49.1 65.0 45.0 0.0 5.00 a 6161471.50 2310774.52 5.00 RECEIVERS R6 40.0 39.4 46.1 65.0 45.0 0.0 5.00 a 6159739.11 2311421.01 5.00 RECEIVERS R7 37.3 35.5 42.4 65.0 45.0 0.0 5.00 a 6159775.06 2314442.86 5.00 RECEIVERS R8 33.4 33.0 39.7 65.0 45.0 0.0 5.00 a 6160277.95 2317097.00 5.00 Point Source(s)
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) POINTSOURCE TRASH26 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6161900.94 2312817.25 5.00 POINTSOURCE TRASH25 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6161896.66 2312112.21 5.00 POINTSOURCE TRASH24 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6161930.85 2313706.03 5.00 POINTSOURCE TRASH23 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6161922.30 2313139.86 5.00 POINTSOURCE TRASH22 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6161967.45 2310918.08 5.00 POINTSOURCE TRASH21 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6162681.62 2310733.34 5.00 POINTSOURCE TRASH20 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6162993.21 2310719.55 5.00 POINTSOURCE TRASH19 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6162698.16 2310603.74 5.00 POINTSOURCE TRASH18 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163166.92 2310476.90 5.00 POINTSOURCE TRASH17 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163588.81 2310716.79 5.00 Urban Crossroads, Inc.
133
6055
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) POINTSOURCE TRASH16 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163610.87 2310474.14 5.00 POINTSOURCE TRASH15 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163892.12 2310722.31 5.00 POINTSOURCE TRASH14 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164272.65 2310711.28 5.00 POINTSOURCE TRASH13 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163914.18 2310482.41 5.00 POINTSOURCE TRASH12 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164366.40 2310446.57 5.00 POINTSOURCE TRASH11 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164462.91 2310443.81 5.00 POINTSOURCE TRASH10 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164713.83 2310540.32 5.00 POINTSOURCE TRASH09 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164815.86 2310554.10 5.00 POINTSOURCE TRASH08 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164771.74 2310708.52 5.00 POINTSOURCE TRASH07 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164664.20 2310766.43 5.00 POINTSOURCE TRASH06 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163062.14 2310782.97 5.00 POINTSOURCE TRASH05 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163208.28 2311610.20 5.00 POINTSOURCE TRASH04 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164735.89 2311590.89 5.00 POINTSOURCE TRASH03 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6163842.22 2309695.88 5.00 POINTSOURCE TRASH02 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164810.66 2309683.88 5.00 POINTSOURCE TRASH01 89.0 89.0 89.0 Lw 89 900.00 0.00 270.00 5.00 a 6164678.13 2309626.45 5.00 POINTSOURCE AC01 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163164.50 2311175.81 50.00 POINTSOURCE AC02 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163289.94 2311386.92 50.00 POINTSOURCE AC03 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163418.44 2311172.76 50.00 POINTSOURCE AC04 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163577.53 2311365.50 50.00 POINTSOURCE AC05 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163693.79 2311175.81 50.00 POINTSOURCE AC06 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163816.16 2311356.32 50.00 POINTSOURCE AC07 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163938.54 2311160.52 50.00 POINTSOURCE AC08 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164060.92 2311356.32 50.00 POINTSOURCE AC09 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164186.36 2311157.46 50.00 POINTSOURCE AC10 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164317.91 2311368.56 50.00 POINTSOURCE AC11 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164446.41 2311166.64 50.00 POINTSOURCE AC12 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164565.73 2311368.56 50.00 POINTSOURCE AC13 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164703.40 2311175.81 50.00 POINTSOURCE AC14 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164584.08 2310976.95 50.00 POINTSOURCE AC15 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164317.91 2310980.01 50.00 POINTSOURCE AC16 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164051.74 2310980.01 50.00 POINTSOURCE AC17 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163819.22 2310983.07 50.00 POINTSOURCE AC18 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163565.29 2310989.19 50.00 POINTSOURCE AC19 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163277.70 2310998.37 50.00 POINTSOURCE AC20 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161720.45 2310921.88 50.00 POINTSOURCE AC21 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161732.69 2311148.28 50.00 POINTSOURCE AC22 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6162001.92 2311163.58 50.00 POINTSOURCE AC23 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161864.24 2311282.89 50.00 POINTSOURCE AC24 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161732.69 2311405.27 50.00 POINTSOURCE AC25 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161588.89 2312142.60 50.00 POINTSOURCE AC26 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161695.97 2312271.09 50.00 POINTSOURCE AC27 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161579.71 2312387.35 50.00 POINTSOURCE AC28 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161683.73 2312567.86 50.00 POINTSOURCE AC29 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161552.18 2312708.59 50.00 POINTSOURCE AC30 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161503.23 2313678.44 50.00 POINTSOURCE AC31 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161503.23 2313225.64 50.00 POINTSOURCE AC32 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161356.37 2313302.12 50.00 POINTSOURCE AC33 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161643.96 2313323.54 50.00 POINTSOURCE AC34 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161490.99 2313433.68 50.00 POINTSOURCE AC35 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161350.26 2313559.12 50.00 POINTSOURCE AC36 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161643.96 2313565.24 50.00 POINTSOURCE AC37 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164757.93 2309454.12 30.00 POINTSOURCE AC38 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164760.47 2309572.12 30.00 POINTSOURCE AC39 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164794.17 2310054.17 30.00 POINTSOURCE AC40 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164786.67 2309796.32 30.00 POINTSOURCE AC41 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164620.27 2309794.82 30.00 POINTSOURCE AC42 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164378.91 2309800.81 30.00 POINTSOURCE AC43 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164121.06 2309803.81 30.00 POINTSOURCE AC44 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163881.20 2309814.31 30.00 POINTSOURCE AC45 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163872.21 2310088.65 30.00 POINTSOURCE AC46 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164942.70 2310526.53 30.00 POINTSOURCE AC47 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164835.16 2310463.11 30.00 POINTSOURCE AC48 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164716.59 2310460.35 30.00 POINTSOURCE AC49 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164545.63 2310493.44 30.00 POINTSOURCE AC50 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164658.69 2310678.19 30.00 POINTSOURCE AC51 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164245.07 2310463.11 30.00 POINTSOURCE AC52 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164189.92 2310595.47 30.00 POINTSOURCE AC53 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164013.45 2310498.96 30.00 POINTSOURCE AC54 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163820.43 2310689.22 30.00 POINTSOURCE AC55 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163710.13 2310689.22 30.00 POINTSOURCE AC56 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163519.87 2310474.14 30.00 POINTSOURCE AC57 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163279.98 2310490.68 30.00 POINTSOURCE AC58 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163081.44 2310680.95 30.00 POINTSOURCE AC59 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6162896.70 2310658.89 30.00 POINTSOURCE AC60 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6162731.25 2310487.93 30.00 POINTSOURCE AC61 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6162579.59 2310620.28 30.00 Urban Crossroads, Inc.
134
6056
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) POINTSOURCE AC62 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164807.59 2310970.47 50.00 POINTSOURCE AC63 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6164804.83 2311397.87 50.00 POINTSOURCE AC64 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6162998.72 2311006.32 50.00 POINTSOURCE AC65 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6163106.26 2311397.87 50.00 POINTSOURCE AC66 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161711.01 2310725.06 50.00 POINTSOURCE AC67 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161981.23 2311428.21 50.00 POINTSOURCE AC68 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161717.20 2312022.48 50.00 POINTSOURCE AC69 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161548.42 2312020.34 50.00 POINTSOURCE AC70 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161693.70 2312806.57 50.00 POINTSOURCE AC71 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161428.78 2312819.39 50.00 POINTSOURCE AC72 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161345.45 2313116.36 50.00 POINTSOURCE AC73 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161648.83 2313118.49 50.00 POINTSOURCE AC74 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161668.06 2313782.94 50.00 POINTSOURCE AC75 88.9 88.9 88.9 Lw 88.9 585.00 0.00 252.00 5.00 g 6161341.18 2313789.35 50.00 POINTSOURCE CAR00 81.1 81.1 81.1 Lw 81.1 5.00 a 6164757.95 2310543.07 5.00 POINTSOURCE CAR01 81.1 81.1 81.1 Lw 81.1 5.00 a 6164854.46 2310543.07 5.00 POINTSOURCE CAR01 81.1 81.1 81.1 Lw 81.1 5.00 a 6164899.69 2309600.13 5.00 POINTSOURCE CAR02 81.1 81.1 81.1 Lw 81.1 5.00 a 6164818.62 2310661.64 5.00 POINTSOURCE CAR02 81.1 81.1 81.1 Lw 81.1 5.00 a 6164841.97 2309560.23 5.00 POINTSOURCE CAR03 81.1 81.1 81.1 Lw 81.1 5.00 a 6164895.82 2310667.16 5.00 POINTSOURCE CAR03 81.1 81.1 81.1 Lw 81.1 5.00 a 6164892.05 2309518.64 5.00 POINTSOURCE CAR04 81.1 81.1 81.1 Lw 81.1 5.00 a 6164950.97 2310951.17 5.00 POINTSOURCE CAR04 81.1 81.1 81.1 Lw 81.1 5.00 a 6164847.91 2309454.12 5.00 POINTSOURCE CAR05 81.1 81.1 81.1 Lw 81.1 5.00 a 6164953.73 2311066.98 5.00 POINTSOURCE CAR05 81.1 81.1 81.1 Lw 81.1 5.00 a 6164880.17 2309383.66 5.00 POINTSOURCE CAR06 81.1 81.1 81.1 Lw 81.1 5.00 a 6164956.49 2311199.34 5.00 POINTSOURCE CAR06 81.1 81.1 81.1 Lw 81.1 5.00 a 6164791.04 2309381.12 5.00 POINTSOURCE CAR07 81.1 81.1 81.1 Lw 81.1 5.00 a 6164953.73 2311339.97 5.00 POINTSOURCE CAR07 81.1 81.1 81.1 Lw 81.1 5.00 a 6164679.83 2309399.79 5.00 POINTSOURCE CAR08 81.1 81.1 81.1 Lw 81.1 5.00 a 6162882.91 2310959.44 5.00 POINTSOURCE CAR08 81.1 81.1 81.1 Lw 81.1 5.00 a 6164677.28 2309493.17 5.00 POINTSOURCE CAR09 81.1 81.1 81.1 Lw 81.1 5.00 a 6162758.82 2310953.93 5.00 POINTSOURCE CAR09 81.1 81.1 81.1 Lw 81.1 5.00 a 6164678.13 2309575.51 5.00 POINTSOURCE CAR10 81.1 81.1 81.1 Lw 81.1 5.00 a 6162827.76 2311039.41 5.00 POINTSOURCE CAR10 81.1 81.1 81.1 Lw 81.1 5.00 a 6164893.11 2310111.13 5.00 POINTSOURCE CAR11 81.1 81.1 81.1 Lw 81.1 5.00 a 6162893.94 2311124.89 5.00 POINTSOURCE CAR11 81.1 81.1 81.1 Lw 81.1 5.00 a 6164890.11 2309974.71 5.00 POINTSOURCE CAR12 81.1 81.1 81.1 Lw 81.1 5.00 a 6162472.05 2311237.94 5.00 POINTSOURCE CAR12 81.1 81.1 81.1 Lw 81.1 5.00 a 6164887.11 2309842.79 5.00 POINTSOURCE CAR13 81.1 81.1 81.1 Lw 81.1 5.00 a 6162455.51 2311339.97 5.00 POINTSOURCE CAR13 81.1 81.1 81.1 Lw 81.1 5.00 a 6164872.12 2309700.37 5.00 POINTSOURCE CAR14 81.1 81.1 81.1 Lw 81.1 5.00 a 6162436.21 2311464.05 5.00 POINTSOURCE CAR14 81.1 81.1 81.1 Lw 81.1 5.00 a 6164735.70 2309704.87 5.00 POINTSOURCE CAR15 81.1 81.1 81.1 Lw 81.1 5.00 a 6162571.32 2311466.81 5.00 POINTSOURCE CAR15 81.1 81.1 81.1 Lw 81.1 5.00 a 6164582.79 2309709.37 5.00 POINTSOURCE CAR16 81.1 81.1 81.1 Lw 81.1 5.00 a 6162640.26 2311160.74 5.00 POINTSOURCE CAR16 81.1 81.1 81.1 Lw 81.1 5.00 a 6164444.87 2309710.87 5.00 POINTSOURCE CAR17 81.1 81.1 81.1 Lw 81.1 5.00 a 6162670.59 2311279.31 5.00 POINTSOURCE CAR17 81.1 81.1 81.1 Lw 81.1 5.00 a 6164302.45 2309709.37 5.00 POINTSOURCE CAR18 81.1 81.1 81.1 Lw 81.1 5.00 a 6162725.74 2311386.84 5.00 POINTSOURCE CAR18 81.1 81.1 81.1 Lw 81.1 5.00 a 6164181.03 2309710.87 5.00 POINTSOURCE CAR19 81.1 81.1 81.1 Lw 81.1 5.00 a 6162797.43 2311475.08 5.00 POINTSOURCE CAR19 81.1 81.1 81.1 Lw 81.1 5.00 a 6164035.61 2309715.37 5.00 POINTSOURCE CAR20 81.1 81.1 81.1 Lw 81.1 5.00 a 6162778.13 2311251.73 5.00 POINTSOURCE CAR20 81.1 81.1 81.1 Lw 81.1 5.00 a 6163891.70 2309713.87 5.00 POINTSOURCE CAR21 81.1 81.1 81.1 Lw 81.1 5.00 a 6162858.09 2311356.51 5.00 POINTSOURCE CAR21 81.1 81.1 81.1 Lw 81.1 5.00 a 6163773.27 2309727.36 5.00 POINTSOURCE CAR22 81.1 81.1 81.1 Lw 81.1 5.00 a 6162935.30 2311464.05 5.00 POINTSOURCE CAR22 81.1 81.1 81.1 Lw 81.1 5.00 a 6163770.27 2309851.78 5.00 POINTSOURCE CAR23 81.1 81.1 81.1 Lw 81.1 5.00 a 6163051.11 2311599.17 5.00 POINTSOURCE CAR23 81.1 81.1 81.1 Lw 81.1 5.00 a 6163770.27 2309967.22 5.00 POINTSOURCE CAR24 81.1 81.1 81.1 Lw 81.1 5.00 a 6162904.97 2311596.41 5.00 POINTSOURCE CAR24 81.1 81.1 81.1 Lw 81.1 5.00 a 6163773.27 2310090.15 5.00 POINTSOURCE CAR25 81.1 81.1 81.1 Lw 81.1 5.00 a 6162598.89 2311604.68 5.00 POINTSOURCE CAR25 81.1 81.1 81.1 Lw 81.1 5.00 a 6164791.17 2310148.61 5.00 POINTSOURCE CAR26 81.1 81.1 81.1 Lw 81.1 5.00 a 6161923.33 2310595.47 5.00 POINTSOURCE CAR26 81.1 81.1 81.1 Lw 81.1 5.00 a 6163893.19 2310159.10 5.00 POINTSOURCE CAR27 81.1 81.1 81.1 Lw 81.1 5.00 a 6162229.40 2311102.83 5.00 POINTSOURCE CAR27 81.1 81.1 81.1 Lw 81.1 5.00 a 6164113.57 2310154.61 5.00 POINTSOURCE CAR28 81.1 81.1 81.1 Lw 81.1 5.00 a 6162212.86 2311304.12 5.00 POINTSOURCE CAR28 81.1 81.1 81.1 Lw 81.1 5.00 a 6164294.96 2310157.61 5.00 POINTSOURCE CAR29 81.1 81.1 81.1 Lw 81.1 5.00 a 6162113.59 2311574.35 5.00 POINTSOURCE CAR29 81.1 81.1 81.1 Lw 81.1 5.00 a 6164480.85 2310151.61 5.00 POINTSOURCE CAR30 81.1 81.1 81.1 Lw 81.1 5.00 a 6161826.82 2311568.83 5.00 POINTSOURCE CAR30 81.1 81.1 81.1 Lw 81.1 5.00 a 6164635.26 2310156.11 5.00 POINTSOURCE CAR31 81.1 81.1 81.1 Lw 81.1 5.00 a 6161575.89 2311577.11 5.00 POINTSOURCE CAR31 81.1 81.1 81.1 Lw 81.1 5.00 a 6164630.76 2310007.69 5.00 Urban Crossroads, Inc.
135
6057
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) POINTSOURCE CAR32 81.1 81.1 81.1 Lw 81.1 5.00 a 6161584.16 2311331.70 5.00 POINTSOURCE CAR32 81.1 81.1 81.1 Lw 81.1 5.00 a 6164569.30 2310079.65 5.00 POINTSOURCE CAR33 81.1 81.1 81.1 Lw 81.1 5.00 a 6161584.16 2311072.50 5.00 POINTSOURCE CAR33 81.1 81.1 81.1 Lw 81.1 5.00 a 6164573.80 2309907.25 5.00 POINTSOURCE CAR34 81.1 81.1 81.1 Lw 81.1 5.00 a 6161581.41 2310788.49 5.00 POINTSOURCE CAR34 81.1 81.1 81.1 Lw 81.1 5.00 a 6164393.90 2309908.75 5.00 POINTSOURCE CAR35 81.1 81.1 81.1 Lw 81.1 5.00 a 6161575.89 2310548.59 5.00 POINTSOURCE CAR35 81.1 81.1 81.1 Lw 81.1 5.00 a 6164462.86 2309995.70 5.00 POINTSOURCE CAR36 81.1 81.1 81.1 Lw 81.1 5.00 a 6162041.95 2312159.21 5.00 POINTSOURCE CAR36 81.1 81.1 81.1 Lw 81.1 5.00 a 6164387.90 2310084.15 5.00 POINTSOURCE CAR37 81.1 81.1 81.1 Lw 81.1 5.00 a 6162146.63 2312261.77 5.00 POINTSOURCE CAR37 81.1 81.1 81.1 Lw 81.1 5.00 a 6164294.96 2309994.20 5.00 POINTSOURCE CAR38 81.1 81.1 81.1 Lw 81.1 5.00 a 6162071.86 2312372.86 5.00 POINTSOURCE CAR38 81.1 81.1 81.1 Lw 81.1 5.00 a 6164208.01 2309904.25 5.00 POINTSOURCE CAR39 81.1 81.1 81.1 Lw 81.1 5.00 a 6162035.54 2312518.14 5.00 POINTSOURCE CAR39 81.1 81.1 81.1 Lw 81.1 5.00 a 6164206.51 2310087.15 5.00 POINTSOURCE CAR40 81.1 81.1 81.1 Lw 81.1 5.00 a 6162172.27 2312573.69 5.00 POINTSOURCE CAR40 81.1 81.1 81.1 Lw 81.1 5.00 a 6164112.07 2309994.20 5.00 POINTSOURCE CAR41 81.1 81.1 81.1 Lw 81.1 5.00 a 6162080.40 2312716.84 5.00 POINTSOURCE CAR41 81.1 81.1 81.1 Lw 81.1 5.00 a 6164014.62 2309902.76 5.00 POINTSOURCE CAR42 81.1 81.1 81.1 Lw 81.1 5.00 a 6162195.77 2312838.62 5.00 POINTSOURCE CAR42 81.1 81.1 81.1 Lw 81.1 5.00 a 6164013.12 2310102.14 5.00 POINTSOURCE CAR43 81.1 81.1 81.1 Lw 81.1 5.00 a 6162007.76 2312874.94 5.00 POINTSOURCE CAR43 81.1 81.1 81.1 Lw 81.1 5.00 a 6162040.42 2310723.02 5.00 POINTSOURCE CAR44 81.1 81.1 81.1 Lw 81.1 5.00 a 6162114.59 2313056.54 5.00 POINTSOURCE CAR44 81.1 81.1 81.1 Lw 81.1 5.00 a 6162095.53 2310808.74 5.00 POINTSOURCE CAR45 81.1 81.1 81.1 Lw 81.1 5.00 a 6162266.28 2313182.59 5.00 POINTSOURCE CAR45 81.1 81.1 81.1 Lw 81.1 5.00 a 6162169.01 2310911.30 5.00 POINTSOURCE CAR46 81.1 81.1 81.1 Lw 81.1 5.00 a 6162101.77 2313206.09 5.00 POINTSOURCE CAR46 81.1 81.1 81.1 Lw 81.1 5.00 a 6162193.50 2310989.37 5.00 POINTSOURCE CAR47 81.1 81.1 81.1 Lw 81.1 5.00 a 6162123.13 2313342.82 5.00 POINTSOURCE CAR47 81.1 81.1 81.1 Lw 81.1 5.00 a 6162169.01 2311148.57 5.00 POINTSOURCE CAR48 81.1 81.1 81.1 Lw 81.1 5.00 a 6162157.32 2313532.97 5.00 POINTSOURCE CAR48 81.1 81.1 81.1 Lw 81.1 5.00 a 6162173.60 2311402.67 5.00 POINTSOURCE CAR49 81.1 81.1 81.1 Lw 81.1 5.00 a 6162146.63 2313735.94 5.00 POINTSOURCE CAR49 81.1 81.1 81.1 Lw 81.1 5.00 a 6162221.05 2311194.49 5.00 POINTSOURCE CAR50 81.1 81.1 81.1 Lw 81.1 5.00 a 6162189.36 2312114.35 5.00 POINTSOURCE CAR50 81.1 81.1 81.1 Lw 81.1 5.00 a 6162098.59 2311505.23 5.00 POINTSOURCE CAR51 81.1 81.1 81.1 Lw 81.1 5.00 a 6162272.69 2312248.95 5.00 POINTSOURCE CAR51 81.1 81.1 81.1 Lw 81.1 5.00 a 6161970.01 2311564.93 5.00 POINTSOURCE CAR52 81.1 81.1 81.1 Lw 81.1 5.00 a 6162229.96 2312428.41 5.00 POINTSOURCE CAR52 81.1 81.1 81.1 Lw 81.1 5.00 a 6161706.72 2311567.99 5.00 POINTSOURCE CAR53 81.1 81.1 81.1 Lw 81.1 5.00 a 6162334.64 2312567.28 5.00 POINTSOURCE CAR53 81.1 81.1 81.1 Lw 81.1 5.00 a 6161584.26 2311459.31 5.00 POINTSOURCE CAR54 81.1 81.1 81.1 Lw 81.1 5.00 a 6162264.14 2312727.52 5.00 POINTSOURCE CAR54 81.1 81.1 81.1 Lw 81.1 5.00 a 6161585.79 2311199.08 5.00 POINTSOURCE CAR55 81.1 81.1 81.1 Lw 81.1 5.00 a 6161674.47 2313020.22 5.00 POINTSOURCE CAR55 81.1 81.1 81.1 Lw 81.1 5.00 a 6161587.32 2310920.49 5.00 POINTSOURCE CAR56 81.1 81.1 81.1 Lw 81.1 5.00 a 6161546.28 2312917.66 5.00 POINTSOURCE CAR56 81.1 81.1 81.1 Lw 81.1 5.00 a 6161582.73 2310660.26 5.00 POINTSOURCE CAR57 81.1 81.1 81.1 Lw 81.1 5.00 a 6161433.05 2313024.49 5.00 POINTSOURCE CAR57 81.1 81.1 81.1 Lw 81.1 5.00 a 6161686.82 2310599.03 5.00 POINTSOURCE CAR58 81.1 81.1 81.1 Lw 81.1 5.00 a 6162368.83 2312849.30 5.00 POINTSOURCE CAR58 81.1 81.1 81.1 Lw 81.1 5.00 a 6161697.54 2310505.65 5.00 POINTSOURCE CAR59 81.1 81.1 81.1 Lw 81.1 5.00 a 6162212.86 2311958.39 5.00 POINTSOURCE CAR59 81.1 81.1 81.1 Lw 81.1 5.00 a 6161764.89 2310608.21 5.00 POINTSOURCE CAR60 81.1 81.1 81.1 Lw 81.1 5.00 a 6162024.85 2311969.07 5.00 POINTSOURCE CAR60 81.1 81.1 81.1 Lw 81.1 5.00 a 6162002.15 2310608.21 5.00 POINTSOURCE CAR61 81.1 81.1 81.1 Lw 81.1 5.00 a 6161819.75 2311973.34 5.00 POINTSOURCE CAR61 81.1 81.1 81.1 Lw 81.1 5.00 a 6161963.89 2310677.10 5.00 POINTSOURCE CAR62 81.1 81.1 81.1 Lw 81.1 5.00 a 6161409.55 2311996.84 5.00 POINTSOURCE CAR62 81.1 81.1 81.1 Lw 81.1 5.00 a 6161913.37 2310530.15 5.00 POINTSOURCE CAR63 81.1 81.1 81.1 Lw 81.1 5.00 a 6161490.73 2312154.94 5.00 POINTSOURCE CAR63 81.1 81.1 81.1 Lw 81.1 5.00 a 6162802.94 2310565.13 5.00 POINTSOURCE CAR64 81.1 81.1 81.1 Lw 81.1 5.00 a 6161405.27 2312310.90 5.00 POINTSOURCE CAR64 81.1 81.1 81.1 Lw 81.1 5.00 a 6162689.89 2310565.13 5.00 POINTSOURCE CAR65 81.1 81.1 81.1 Lw 81.1 5.00 a 6161467.23 2312492.51 5.00 POINTSOURCE CAR65 81.1 81.1 81.1 Lw 81.1 5.00 a 6162692.65 2310683.70 5.00 POINTSOURCE CAR66 81.1 81.1 81.1 Lw 81.1 5.00 a 6161309.13 2312545.92 5.00 POINTSOURCE CAR66 81.1 81.1 81.1 Lw 81.1 5.00 a 6162739.52 2310609.25 5.00 POINTSOURCE CAR67 81.1 81.1 81.1 Lw 81.1 5.00 a 6161298.45 2312723.25 5.00 POINTSOURCE CAR67 81.1 81.1 81.1 Lw 81.1 5.00 a 6162789.16 2310667.16 5.00 POINTSOURCE CAR68 81.1 81.1 81.1 Lw 81.1 5.00 a 6161198.04 2312815.11 5.00 POINTSOURCE CAR68 81.1 81.1 81.1 Lw 81.1 5.00 a 6162995.96 2310642.34 5.00 POINTSOURCE CAR69 81.1 81.1 81.1 Lw 81.1 5.00 a 6161277.09 2312909.12 5.00 POINTSOURCE CAR69 81.1 81.1 81.1 Lw 81.1 5.00 a 6162938.06 2310595.47 5.00 POINTSOURCE CAR70 81.1 81.1 81.1 Lw 81.1 5.00 a 6162287.64 2313060.81 5.00 Urban Crossroads, Inc.
136
6058
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) POINTSOURCE CAR70 81.1 81.1 81.1 Lw 81.1 5.00 a 6162940.81 2310485.17 5.00 POINTSOURCE CAR71 81.1 81.1 81.1 Lw 81.1 5.00 a 6162373.10 2313223.18 5.00 POINTSOURCE CAR71 81.1 81.1 81.1 Lw 81.1 5.00 a 6163001.48 2310556.86 5.00 POINTSOURCE CAR72 81.1 81.1 81.1 Lw 81.1 5.00 a 6162272.69 2313351.37 5.00 POINTSOURCE CAR72 81.1 81.1 81.1 Lw 81.1 5.00 a 6163006.99 2310487.93 5.00 POINTSOURCE CAR73 81.1 81.1 81.1 Lw 81.1 5.00 a 6162368.83 2313515.88 5.00 POINTSOURCE CAR73 81.1 81.1 81.1 Lw 81.1 5.00 a 6163084.20 2310562.38 5.00 POINTSOURCE CAR74 81.1 81.1 81.1 Lw 81.1 5.00 a 6162274.82 2313644.07 5.00 POINTSOURCE CAR74 81.1 81.1 81.1 Lw 81.1 5.00 a 6163097.99 2310479.65 5.00 POINTSOURCE CAR75 81.1 81.1 81.1 Lw 81.1 5.00 a 6162366.69 2313755.16 5.00 POINTSOURCE CAR75 81.1 81.1 81.1 Lw 81.1 5.00 a 6163153.14 2310534.80 5.00 POINTSOURCE CAR76 81.1 81.1 81.1 Lw 81.1 5.00 a 6162240.64 2313894.04 5.00 POINTSOURCE CAR76 81.1 81.1 81.1 Lw 81.1 5.00 a 6163279.98 2310576.16 5.00 POINTSOURCE CAR77 81.1 81.1 81.1 Lw 81.1 5.00 a 6162071.86 2313894.04 5.00 POINTSOURCE CAR77 81.1 81.1 81.1 Lw 81.1 5.00 a 6163200.01 2310609.25 5.00 POINTSOURCE CAR78 81.1 81.1 81.1 Lw 81.1 5.00 a 6161926.58 2313921.81 5.00 POINTSOURCE CAR78 81.1 81.1 81.1 Lw 81.1 5.00 a 6163202.77 2310703.01 5.00 POINTSOURCE CAR79 81.1 81.1 81.1 Lw 81.1 5.00 a 6161791.98 2313853.44 5.00 POINTSOURCE CAR79 81.1 81.1 81.1 Lw 81.1 5.00 a 6163266.19 2310647.86 5.00 POINTSOURCE CAR80 81.1 81.1 81.1 Lw 81.1 5.00 a 6161638.15 2313930.36 5.00 POINTSOURCE CAR80 81.1 81.1 81.1 Lw 81.1 5.00 a 6163340.64 2310603.74 5.00 POINTSOURCE CAR81 81.1 81.1 81.1 Lw 81.1 5.00 a 6161488.60 2313874.81 5.00 POINTSOURCE CAR81 81.1 81.1 81.1 Lw 81.1 5.00 a 6163337.88 2310700.25 5.00 POINTSOURCE CAR82 81.1 81.1 81.1 Lw 81.1 5.00 a 6161339.04 2313926.08 5.00 POINTSOURCE CAR82 81.1 81.1 81.1 Lw 81.1 5.00 a 6163580.54 2310565.13 5.00 POINTSOURCE CAR83 81.1 81.1 81.1 Lw 81.1 5.00 a 6161195.90 2313054.40 5.00 POINTSOURCE CAR83 81.1 81.1 81.1 Lw 81.1 5.00 a 6163492.30 2310573.41 5.00 POINTSOURCE CAR84 81.1 81.1 81.1 Lw 81.1 5.00 a 6161264.27 2313201.82 5.00 POINTSOURCE CAR84 81.1 81.1 81.1 Lw 81.1 5.00 a 6163511.60 2310675.43 5.00 POINTSOURCE CAR85 81.1 81.1 81.1 Lw 81.1 5.00 a 6161193.76 2313312.91 5.00 POINTSOURCE CAR85 81.1 81.1 81.1 Lw 81.1 5.00 a 6163599.84 2310672.67 5.00 POINTSOURCE CAR86 81.1 81.1 81.1 Lw 81.1 5.00 a 6161259.99 2313481.70 5.00 POINTSOURCE CAR86 81.1 81.1 81.1 Lw 81.1 5.00 a 6163677.04 2310512.74 5.00 POINTSOURCE CAR87 81.1 81.1 81.1 Lw 81.1 5.00 a 6161200.17 2313622.70 5.00 POINTSOURCE CAR87 81.1 81.1 81.1 Lw 81.1 5.00 a 6163754.25 2310570.65 5.00 POINTSOURCE CAR88 81.1 81.1 81.1 Lw 81.1 5.00 a 6161255.72 2313757.30 5.00 POINTSOURCE CAR88 81.1 81.1 81.1 Lw 81.1 5.00 a 6163759.77 2310493.44 5.00 POINTSOURCE CAR89 81.1 81.1 81.1 Lw 81.1 5.00 a 6161206.58 2313896.17 5.00 POINTSOURCE CAR89 81.1 81.1 81.1 Lw 81.1 5.00 a 6163831.46 2310567.89 5.00 POINTSOURCE CAR90 81.1 81.1 81.1 Lw 81.1 5.00 a 6163853.52 2310485.17 5.00 POINTSOURCE CAR91 81.1 81.1 81.1 Lw 81.1 5.00 a 6163922.45 2310548.59 5.00 POINTSOURCE CAR92 81.1 81.1 81.1 Lw 81.1 5.00 a 6163916.94 2310689.22 5.00 POINTSOURCE CAR93 81.1 81.1 81.1 Lw 81.1 5.00 a 6164018.96 2310691.98 5.00 POINTSOURCE CAR94 81.1 81.1 81.1 Lw 81.1 5.00 a 6164432.58 2310592.71 5.00 POINTSOURCE CAR95 81.1 81.1 81.1 Lw 81.1 5.00 a 6164314.01 2310548.59 5.00 POINTSOURCE CAR96 81.1 81.1 81.1 Lw 81.1 5.00 a 6164443.61 2310507.23 5.00 POINTSOURCE CAR97 81.1 81.1 81.1 Lw 81.1 5.00 a 6164327.80 2310667.16 5.00 POINTSOURCE CAR98 81.1 81.1 81.1 Lw 81.1 5.00 a 6164418.79 2310669.92 5.00 POINTSOURCE CAR99 81.1 81.1 81.1 Lw 81.1 5.00 a 6164515.30 2310669.92 5.00 POINTSOURCE DOCK01 103.4 103.4 103.4 Lw 103.4 8.00 a 6161950.11 2310830.17 8.00 POINTSOURCE DOCK02 103.4 103.4 103.4 Lw 103.4 8.00 a 6161996.03 2311076.62 8.00 POINTSOURCE DOCK03 103.4 103.4 103.4 Lw 103.4 8.00 a 6161928.68 2310977.13 8.00 POINTSOURCE DOCK04 103.4 103.4 103.4 Lw 103.4 8.00 a 6161847.55 2310948.04 8.00 POINTSOURCE DOCK13 103.4 103.4 103.4 Lw 103.4 8.00 a 6164570.45 2311585.38 8.00 POINTSOURCE DOCK14 103.4 103.4 103.4 Lw 103.4 8.00 a 6164336.07 2311590.89 8.00 POINTSOURCE DOCK15 103.4 103.4 103.4 Lw 103.4 8.00 a 6164093.41 2311590.89 8.00 POINTSOURCE DOCK16 103.4 103.4 103.4 Lw 103.4 8.00 a 6163892.12 2311593.65 8.00 POINTSOURCE DOCK17 103.4 103.4 103.4 Lw 103.4 8.00 a 6163682.56 2311599.17 8.00 POINTSOURCE DOCK18 103.4 103.4 103.4 Lw 103.4 8.00 a 6163478.51 2311596.41 8.00 POINTSOURCE DOCK19 103.4 103.4 103.4 Lw 103.4 8.00 a 6163285.49 2311596.41 8.00 POINTSOURCE DOCK30 103.4 103.4 103.4 Lw 103.4 8.00 a 6164666.96 2311466.81 8.00 POINTSOURCE DOCK31 103.4 103.4 103.4 Lw 103.4 8.00 a 6164435.33 2311475.08 8.00 POINTSOURCE DOCK32 103.4 103.4 103.4 Lw 103.4 8.00 a 6164209.23 2311472.32 8.00 POINTSOURCE DOCK33 103.4 103.4 103.4 Lw 103.4 8.00 a 6163980.36 2311477.84 8.00 POINTSOURCE DOCK34 103.4 103.4 103.4 Lw 103.4 8.00 a 6163776.31 2311483.35 8.00 POINTSOURCE DOCK35 103.4 103.4 103.4 Lw 103.4 8.00 a 6163577.78 2311483.35 8.00 POINTSOURCE DOCK36 103.4 103.4 103.4 Lw 103.4 8.00 a 6163393.03 2311491.63 8.00 POINTSOURCE DOCK38 103.4 103.4 103.4 Lw 103.4 8.00 a 6161870.94 2310876.72 8.00 POINTSOURCE DOCK39 103.4 103.4 103.4 Lw 103.4 8.00 a 6162006.05 2311011.84 8.00 POINTSOURCE DOCK40 103.4 103.4 103.4 Lw 103.4 8.00 a 6161887.48 2311053.20 8.00 POINTSOURCE DOCK41 103.4 103.4 103.4 Lw 103.4 8.00 a 6161937.26 2312148.53 8.00 POINTSOURCE DOCK42 103.4 103.4 103.4 Lw 103.4 8.00 a 6161787.70 2312206.22 8.00 POINTSOURCE DOCK43 103.4 103.4 103.4 Lw 103.4 8.00 a 6161937.26 2312298.09 8.00 POINTSOURCE DOCK44 103.4 103.4 103.4 Lw 103.4 8.00 a 6161785.57 2312389.95 8.00 POINTSOURCE DOCK45 103.4 103.4 103.4 Lw 103.4 8.00 a 6161939.39 2312481.82 8.00 POINTSOURCE DOCK46 103.4 103.4 103.4 Lw 103.4 8.00 a 6161783.43 2312558.74 8.00 POINTSOURCE DOCK47 103.4 103.4 103.4 Lw 103.4 8.00 a 6161939.39 2312676.24 8.00 Urban Crossroads, Inc.
137
6059
Name M. ID Result. PWL Lw / Li Operating Time Height Coordinates Day Evening Night Type Value norm. Day Special Night X Y Z (dBA) (dBA) (dBA) dB(A) (min) (min) (min) (ft) (ft) (ft) (ft) POINTSOURCE DOCK48 103.4 103.4 103.4 Lw 103.4 8.00 a 6161779.16 2312742.47 8.00 POINTSOURCE DOCK55 103.4 103.4 103.4 Lw 103.4 8.00 a 6161802.66 2313122.77 8.00 POINTSOURCE DOCK56 103.4 103.4 103.4 Lw 103.4 8.00 a 6161740.70 2313214.64 8.00 POINTSOURCE DOCK57 103.4 103.4 103.4 Lw 103.4 8.00 a 6161811.21 2313355.64 8.00 POINTSOURCE DOCK58 103.4 103.4 103.4 Lw 103.4 8.00 a 6161749.25 2313468.88 8.00 POINTSOURCE DOCK59 103.4 103.4 103.4 Lw 103.4 8.00 a 6161811.21 2313603.47 8.00 POINTSOURCE DOCK60 103.4 103.4 103.4 Lw 103.4 8.00 a 6161762.07 2313742.35 8.00 POINTSOURCE PARK01 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6163785.18 2309430.76 5.00 POINTSOURCE PARK02 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6163649.65 2309423.98 5.00 POINTSOURCE PARK03 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6163724.19 2309539.19 5.00 POINTSOURCE PARK04 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160661.03 2309823.82 5.00 POINTSOURCE PARK05 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160694.91 2309722.17 5.00 POINTSOURCE PARK06 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160566.15 2309762.83 5.00 POINTSOURCE PARK07 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160722.02 2311158.87 5.00 POINTSOURCE PARK08 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160708.47 2311043.66 5.00 POINTSOURCE PARK09 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160606.81 2311145.32 5.00 POINTSOURCE PARK10 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6161054.09 2312466.82 5.00 POINTSOURCE PARK11 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160986.32 2312358.39 5.00 POINTSOURCE PARK12 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160935.18 2312478.06 5.00 POINTSOURCE PARK13 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160467.36 2313605.61 5.00 POINTSOURCE PARK14 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160465.22 2313276.59 5.00 POINTSOURCE PARK15 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160674.60 2313225.32 5.00 POINTSOURCE PARK16 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160460.95 2313424.01 5.00 POINTSOURCE PARK17 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160646.82 2313609.88 5.00 POINTSOURCE PARK18 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160283.62 2313631.25 5.00 POINTSOURCE PARK19 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160247.30 2313270.18 5.00 POINTSOURCE PARK20 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160832.70 2313601.34 5.00 POINTSOURCE PARK21 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160695.96 2313398.37 5.00 POINTSOURCE PARK22 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160841.24 2313206.09 5.00 POINTSOURCE PARK23 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160762.19 2313037.31 5.00 POINTSOURCE PARK24 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160516.50 2313114.22 5.00 POINTSOURCE PARK25 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160326.35 2313030.90 5.00 POINTSOURCE PARK26 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160012.29 2313020.22 5.00 POINTSOURCE PARK27 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160155.43 2313101.40 5.00 POINTSOURCE PARK28 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160012.29 2313272.32 5.00 POINTSOURCE PARK29 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160166.12 2313473.15 5.00 POINTSOURCE PARK30 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160022.97 2313622.70 5.00 POINTSOURCE PARK31 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160768.60 2313789.35 5.00 POINTSOURCE PARK32 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160610.50 2313908.99 5.00 POINTSOURCE PARK33 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160441.72 2313793.62 5.00 POINTSOURCE PARK34 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160319.94 2313923.95 5.00 POINTSOURCE PARK35 81.4 81.4 81.4 Lw 81.4 900.00 0.00 0.00 5.00 a 6160166.12 2313802.17 5.00 Line Source(s)
Name M. ID Result. PWL Result. PWL' Lw / Li Operating Time Moving Pt. Src Height Day Evening Night Day Evening Night Type Value norm. Day Special Night Number Speed (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) Day Evening Night (mph) (ft) LINESOURCE TRUCK01 93.2 93.2 93.2 63.8 63.8 63.8 Lw 93.2 8 a LINESOURCE TRUCK02 93.2 93.2 93.2 70.6 70.6 70.6 Lw 93.2 8 a LINESOURCE TRUCK03 93.2 93.2 93.2 64.1 64.1 64.1 Lw 93.2 8 a LINESOURCE TRUCK04 93.2 93.2 93.2 64.2 64.2 64.2 Lw 93.2 8 a LINESOURCE TRUCK05 93.2 93.2 93.2 75.8 75.8 75.8 Lw 93.2 8 a LINESOURCE TRUCK06 93.2 93.2 93.2 67.9 67.9 67.9 Lw 93.2 8 a Name Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
LINESOURCE 8.00 a 6162426.51 2313832.08 8.00 0.00
6161851.80 2313838.49 8.00 0.00
6161817.62 2312031.03 8.00 0.00
6162276.96 2312022.48 8.00 0.00
LINESOURCE 8.00 a 6161835.47 2312975.17 8.00 0.00
6162426.51 2312964.67 8.00 0.00
LINESOURCE 8.00 a 6162372.79 2311524.72 8.00 0.00
6165032.50 2311519.05 8.00 0.00
LINESOURCE 8.00 a 6165027.47 2310818.74 8.00 0.00
6162441.72 2310843.63 8.00 0.00
LINESOURCE 8.00 a 6161829.58 2310452.08 8.00 0.00
6161840.60 2310631.31 8.00 0.00
LINESOURCE 8.00 a 6162287.31 2311530.23 8.00 0.00
6162119.10 2311439.24 8.00 0.00
6162108.07 2310901.54 8.00 0.00
6161840.60 2310631.31 8.00 0.00
Area Source(s)
Urban Crossroads, Inc.
138
6060
Name M. ID Result. PWL Result. PWL'' Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm. Day Special Night (ft) (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) 103.4 103.4 103.4 59.4 59.4 59.4 Lw 103.4 0 r
Name Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
0.00 r 6163052.42 2310942.36 0.00 0.00
6163048.57 2310782.69 0.00 0.00
6164706.79 2310755.76 0.00 0.00
6164710.64 2310919.28 0.00 0.00
Barrier(s)
Name M. ID Absorption Z-Ext. Cantilever Height Coordinates left right horz. vert. Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft) (ft) (ft) (ft)
BARRIERPLANNED 0 14.00 a 6163036.39 2310814.91 14.00 0.00 6163036.39 2310755.51 14.00 0.00
6164725.56 2310743.63 14.00 0.00
6164725.56 2310774.52 14.00 0.00
BARRIERPLANNED 0 14.00 a 6162071.52 2313792.99 14.00 0.00 6162063.63 2313087.96 14.00 0.00
BARRIERPLANNED 0 14.00 a 6161996.13 2312835.26 14.00 0.00 6161987.52 2312101.61 14.00 0.00
BARRIERPLANNED 0 14.00 a 6162055.58 2311097.23 14.00 0.00 6162049.44 2310900.62 14.00 0.00
6161876.18 2310727.36 14.00 0.00
BARRIERPLANNED 0 14.00 a 6163235.14 2311631.71 14.00 0.00 6164719.26 2311616.25 14.00 0.00
BARRIERPLANNED 0 14.00 a 6162074.07 2313797.59 14.00 0.00 6161912.18 2313799.97 14.00 0.00
BARRIERPLANNED 0 14.00 a 6161715.77 2313808.30 14.00 0.00 6161800.29 2313805.92 14.00 0.00
BARRIERPLANNED 0 6.00 a 6161504.62 2311329.71 6.00 0.00 6161503.10 2310491.48 6.00 0.00
BARRIERPLANNED 0 6.00 a 6162652.85 2310290.23 6.00 0.00 6164170.64 2310284.46 6.00 0.00
Building(s)
Name M. ID RB Residents Absorption Height Coordinates
Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
BUILDING BUILDING00001 x 0 45.00 a 6161356.14 2312883.48 45.00 0.00 6161753.52 2312879.21 45.00 0.00
6161747.11 2311969.07 45.00 0.00
6161520.64 2311975.48 45.00 0.00
6161522.78 2312471.14 45.00 0.00
6161356.14 2312708.29 45.00 0.00
BUILDING BUILDING00002 x 0 45.00 a 6161279.22 2313855.58 45.00 0.00 6161715.06 2313851.31 45.00 0.00
6161700.11 2313067.22 45.00 0.00
6161268.54 2313062.95 45.00 0.00
BUILDING BUILDING00003 x 0 45.00 a 6161664.13 2311491.63 45.00 0.00 6162050.25 2311485.75 45.00 0.00
6162044.65 2311122.13 45.00 0.00
6161799.24 2311127.65 45.00 0.00
6161788.16 2310660.74 45.00 0.00
6161642.07 2310658.89 45.00 0.00
BUILDING BUILDING00004 x 0 45.00 a 6162960.12 2311287.58 45.00 0.00 6163081.44 2311453.02 45.00 0.00
6164871.01 2311436.48 45.00 0.00
6164854.46 2310929.11 45.00 0.00
6162957.36 2310953.93 45.00 0.00
BUILDING BUILDING00005 x 0 25.00 a 6162557.53 2310703.01 25.00 0.00 6162620.95 2310700.25 25.00 0.00
6162615.44 2310543.07 25.00 0.00
6162552.02 2310551.35 25.00 0.00
BUILDING BUILDING00006 x 0 25.00 a 6162631.98 2310518.26 25.00 0.00 6162825.00 2310512.74 25.00 0.00
6162825.00 2310463.11 25.00 0.00
6162629.23 2310465.87 25.00 0.00
BUILDING BUILDING00007 x 0 25.00 a 6162830.52 2310686.46 25.00 0.00 6162957.36 2310689.22 25.00 0.00
6162954.60 2310631.31 25.00 0.00
6162838.79 2310631.31 25.00 0.00
BUILDING BUILDING00008 x 0 25.00 a 6163026.29 2310736.09 25.00 0.00 6163122.80 2310741.61 25.00 0.00
Urban Crossroads, Inc.
139
6061
Name M. ID RB Residents Absorption Height Coordinates
Begin x y z Ground
(ft) (ft) (ft) (ft) (ft)
6163117.29 2310636.83 25.00 0.00
6163026.29 2310636.83 25.00 0.00
BUILDING BUILDING00009 x 0 25.00 a 6163244.13 2310512.74 25.00 0.00 6163326.85 2310509.99 25.00 0.00
6163329.61 2310463.11 25.00 0.00
6163235.86 2310465.87 25.00 0.00
BUILDING BUILDING00010 x 0 25.00 a 6163453.69 2310501.71 25.00 0.00 6163583.29 2310509.99 25.00 0.00
6163583.29 2310449.32 25.00 0.00
6163448.18 2310452.08 25.00 0.00
BUILDING BUILDING00011 x 0 25.00 a 6163652.23 2310725.06 25.00 0.00 6163859.03 2310730.58 25.00 0.00
6163861.79 2310639.58 25.00 0.00
6163652.23 2310642.34 25.00 0.00
BUILDING BUILDING00012 x 0 25.00 a 6163980.36 2310543.07 25.00 0.00 6164027.24 2310540.32 25.00 0.00
6164027.24 2310454.84 25.00 0.00
6163991.39 2310452.08 25.00 0.00
BUILDING BUILDING00013 x 0 25.00 a 6164165.11 2310664.40 25.00 0.00 6164220.26 2310656.13 25.00 0.00
6164217.50 2310532.05 25.00 0.00
6164165.11 2310537.56 25.00 0.00
BUILDING BUILDING00014 x 0 25.00 a 6164187.17 2310487.93 25.00 0.00 6164300.22 2310493.44 25.00 0.00
6164300.22 2310438.29 25.00 0.00
6164178.89 2310441.05 25.00 0.00
BUILDING BUILDING00015 x 0 25.00 a 6164595.26 2310719.55 25.00 0.00 6164722.11 2310716.79 25.00 0.00
6164716.59 2310634.07 25.00 0.00
6164598.02 2310639.58 25.00 0.00
BUILDING BUILDING00016 x 0 25.00 a 6164512.54 2310529.29 25.00 0.00 6164567.69 2310540.32 25.00 0.00
6164567.69 2310449.32 25.00 0.00
6164520.81 2310452.08 25.00 0.00
BUILDING BUILDING00017 x 0 25.00 a 6164669.71 2310493.44 25.00 0.00 6164749.68 2310487.93 25.00 0.00
6164749.68 2310435.54 25.00 0.00
6164672.47 2310432.78 25.00 0.00
BUILDING BUILDING00018 x 0 25.00 a 6164791.04 2310487.93 25.00 0.00 6164882.04 2310479.65 25.00 0.00
6164882.04 2310430.02 25.00 0.00
6164780.01 2310427.26 25.00 0.00
BUILDING BUILDING00019 x 0 25.00 a 6164915.13 2310548.59 25.00 0.00 6164967.52 2310548.59 25.00 0.00
6164967.52 2310487.93 25.00 0.00
6164909.61 2310498.96 25.00 0.00
BUILDING BUILDING00020 x 0 25.00 a 6163810.74 2310118.63 25.00 0.00 6163939.67 2310118.63 25.00 0.00
6163938.17 2309863.78 25.00 0.00
6164696.72 2309857.78 25.00 0.00
6164699.72 2310102.14 25.00 0.00
6164860.13 2310097.64 25.00 0.00
6164846.64 2309736.35 25.00 0.00
6163807.74 2309755.84 25.00 0.00
BUILDING BUILDING00021 x 0 25.00 a 6164710.39 2309609.47 25.00 0.00 6164808.86 2309606.92 25.00 0.00
6164807.16 2309401.49 25.00 0.00
6164706.15 2309404.04 25.00 0.00
Ground Absorption(s)
Name M. ID G Coordinates
x y
(ft) (ft)
GROUND 0 0.5 6160145.98 2315191.14
6162423.03 2315191.14
6162416.25 2314005.18
6160071.44 2314059.39
GROUND 0 0.5 6162599.22 2314818.41
6163127.82 2314791.30
6163107.49 2314188.15
6164164.69 2314167.82
6164130.81 2311714.58
6162538.23 2311707.80
Urban Crossroads, Inc.
140
6062
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
APPENDIX 11.1:
CADNAA CONSTRUCTION NOISE MODEL INPUTS
141
6063
Rich-Haven Specific Plan-2022 Amendment Noise and Vibration Analysis 14822-04 Noise Study
This page intentionally left blank
142
6064
14822 - Rich Haven Specific Plan
CadnaA Noise Prediction Model: 14822-02_Construction.cna Date: 17.10.22
Analyst: B. Lawson
Calculation Configuration
Configuration
Parameter Value
General
Max. Error (dB) 0.00
Max. Search Radius (#(Unit,LEN)) 2000.01
Min. Dist Src to Rcvr 0.00
Partition
Raster Factor 0.50
Max. Length of Section (#(Unit,LEN)) 999.99
Min. Length of Section (#(Unit,LEN)) 1.01
Min. Length of Section (%) 0.00
Proj. Line Sources On
Proj. Area Sources On
Ref. Time
Reference Time Day (min) 960.00
Reference Time Night (min) 480.00
Daytime Penalty (dB) 0.00
Recr. Time Penalty (dB) 5.00
Night-time Penalty (dB) 10.00
DTM
Standard Height (m) 0.00
Model of Terrain Triangulation
Reflection
max. Order of Reflection 2
Search Radius Src 100.00
Search Radius Rcvr 100.00
Max. Distance Source - Rcvr 1000.00 1000.00
Min. Distance Rvcr - Reflector 1.00 1.00
Min. Distance Source - Reflector 0.10
Industrial (ISO 9613)
Lateral Diffraction some Obj
Obst. within Area Src do not shield On
Screening Incl. Ground Att. over Barrier
Dz with limit (20/25)
Barrier Coefficients C1,2,3 3.0 20.0 0.0
Temperature (#(Unit,TEMP)) 10
rel. Humidity (%) 70
Ground Absorption G 0.50
Wind Speed for Dir. (#(Unit,SPEED)) 3.0
Roads (TNM)
Railways (FTA/FRA)
Aircraft (???)
Strictly acc. to AzB
Receiver Noise Levels
Name M. ID Level Lr Limit. Value Land Use Height Coordinates Day Night CNEL Day Night CNEL Type Auto Noise Type X Y Z (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) (ft) (ft) (ft) (ft) RECEIVERS R1 56.0 -51.0 53.0 65.0 45.0 0.0 5.00 a 6161938.34 2315328.19 5.00 RECEIVERS R2 53.3 -53.6 50.3 65.0 45.0 0.0 5.00 a 6162735.95 2314875.32 5.00 RECEIVERS R3 63.7 -43.3 60.7 65.0 45.0 0.0 5.00 a 6163483.69 2310238.26 5.00 RECEIVERS R4 55.8 -51.1 52.8 65.0 45.0 0.0 5.00 a 6162048.86 2308936.45 5.00 RECEIVERS R5 63.8 -43.2 60.8 65.0 45.0 0.0 5.00 a 6161471.50 2310774.52 5.00 RECEIVERS R6 55.1 -51.9 52.1 65.0 45.0 0.0 5.00 a 6159739.11 2311421.01 5.00 RECEIVERS R7 54.8 -52.2 51.8 65.0 45.0 0.0 5.00 a 6159775.06 2314442.86 5.00 RECEIVERS R8 52.5 -54.5 49.5 65.0 45.0 0.0 5.00 a 6160277.95 2317097.00 5.00 Area Source(s)
Name M. ID Result. PWL Result. PWL'' Lw / Li Operating Time Height Day Evening Night Day Evening Night Type Value norm. Day Special Night (ft) (dBA) (dBA) (dBA) (dBA) (dBA) (dBA) dB(A) (min) (min) (min) SITEBOUNDARY CONSRUCTION 122.0 15.0 15.0 58.3 -48.6 -48.6 PWL-Pt 115 8 a Name Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
SITEBOUNDARY 8.00 a 6159965.00 2316909.01 8.00 0.00
6161260.25 2316906.76 8.00 0.00
6161230.46 2315263.96 8.00 0.00
6162521.69 2315243.59 8.00 0.00
6162473.69 2311651.45 8.00 0.00
Urban Crossroads, Inc.
143
6065
Name Height Coordinates
Begin End x y z Ground
(ft) (ft) (ft) (ft) (ft) (ft)
6165033.26 2311624.61 8.00 0.00
6165014.25 2308981.07 8.00 0.00
6159855.93 2309066.93 8.00 0.00
Urban Crossroads, Inc.
144
6066
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-1
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc
5.5 - HAZARDS
5.5.1 - Introduction
Information in this section is derived from the following site-specific technical studies, other reference documents, and correspondence received.
• Phase I Environmental Site Assessment, Approximate 77-Acre Property, Rich Haven Specific Plan Mixed Use District, RBF Consulting, October 3, 2005. • Phase I Environmental Site Assessment, Approximate 106-Acre Property, Rich Haven Specific Plan Mixed Use District, RBF Consulting, October 3, 2005. • Phase I Environmental Site Assessment, Visser Property, GeoKinetics, February 1, 2003. • Phase I Environmental Site Assessment, Randall Property, GeoKinetics, January 17, 2005. • Phase I Environmental Site Assessment, Di Tommaso Property, GeoKinetics, February 18, 2004.
• Preliminary Subsurface Methane Gas Investigation, Randall Property, GeoKinetics, January 31, 2005.
• Subsurface Methane Gas Investigation, Scritsmier Property, GeoKinetics, January 26, 2004. • Subsurface Methane Gas Investigation, Visser Property, GeoKinetics, February 1, 2003. • Subsurface Methane Gas Investigation, Di Tommaso Property, GeoKinetics, February 18, 2004.
• Subsurface Methane Gas Investigation, Van Der Eyk Property, GeoKinetics, November 25, 2002.
• Letter from the California Department of Toxic Substances Control, June 12, 2006. • NMC Final EIR, City of Ontario, October 1997.
• 1992 General Plan, City of Ontario, September 1992.
The NMC Final EIR identified that hazardous materials and hazardous waste generation are primarily associated with fuels such as gasoline, diesel, and heating oil, and pesticides, and identified a number of recorded sites. The NMC Final EIR concluded that potential impacts regarding hazardous waste sites within the NMC would become fully known when individual subareas are developed through the preparation of Phase I Environmental Site Assessments and, if applicable, the preparation of Phase II Environmental Site Investigations.
6067
Hazards Rich Haven Specific Plan - Draft EIR
5.5-2 Michael Brandman Associates
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc In addition, the NMC Final EIR referenced the likelihood that buildings located within the NMC would contain asbestos and lead-based paints, if constructed prior to 1979 and concluded that leadbased paint and asbestos surveys would be required prior to demolition.
Preparation of this section of the Draft EIR conforms to the recommendations contained in the NMC Final EIR and evaluates additional information specific to the project site that may not have been included in the broad, program-level evaluation of the NMC Final EIR.
5.5.2 - Existing Conditions
Phase I Environmental Site Assessments (ESA) and Subsurface Methane Gas Investigations were conducted for all properties on the site except for the following Assessor’s Parcel Numbers, for which methane studies were not directly indicated:
• 0218-211-25
• 0218-211-12
• 0218-211-21
• 0218-211-15
• 0218-161-04
• 0218-161-05
• 0218-161-01
• 0218-161-11
Hazardous Materials and Risk of Upset
The presence of suspected or known hazardous waste contamination sites within the project site and immediate vicinity was determined through various Phase I ESAs performed by RBF Consulting and GeoKinetics in 2002, 2003, 2004, and 2005. These analyses included a computerized database search of various governmental agency lists. The CEQA Guidelines require a lead agency to consult the lists of hazardous waste sites compiled by various state agencies (Cal EPA, the Department of Health Services, the State Water Resources Control Board, and the California Integrated Waste Management Board) pursuant to Governmental Code Section 65962.5 (California Public Resources Section 21092.6). The database searches included review of all of the required state lists and a search of various federal (EPA) and local (San Bernardino County Fire Department) hazardous waste site lists.
The following environmental issues were discussed within the Phase I ESAs for the project site:
• The potential for asbestos in onsite structures built before the early 1970s. • The potential for lead-based paint on structures that were built before 1978. • Miscellaneous debris (e.g. trash, 55 gallon drums, paint cans, agriculture-related debris) that had been abandoned onsite.
6068
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-3
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc • Utilities such as petroleum lines found onsite.
• Pole-mounted transformers that may contain polychlorinated biphenyls (PCBs). • The potential for onsite septic systems.
• The potential for methane gas onsite in excess of 55,000 parts per million (ppm), which poses an explosion hazard, due to the project site’s past use for dairy and hog farming. • Storage tanks were noted on and near the project site, which may have contained agriculturalrelated chemicals. • The project site was evaluated for the potential presence of radon gas. • The potential for hazardous wastes, such as petroleum waste.
Historically, the project site was comprised of vacant land, onsite structures, agricultural uses, dairy farms, residences, wells, unimproved roads, and power transmission lines. Numerous local, state, and federal databases were searched in preparation for the Phase I ESAs. Databases included the Records of Decision database maintained by the EPA (ROD), CAL-SITES maintained by the California Department of Toxic Substance Control, and the Listing of Underground Tank Cleanup Sites maintained by the County of Riverside. Appendix D, Phase I ESAs and Phase II ESAs, contains the hazardous materials technical reports.
Information obtained by the data base search and contact with relevant governmental agencies indicated the following results:
• The nearby Heritage Dairy (target property) had a cleanup and abatement order issued for it by the California Waste Discharge System database (CAWDS) regarding the discharge of wastes associated with dairy farming operations. The facility is required to allow no waste discharge and water runoff onto surrounding properties. All dairy wastewater and stormwater must be contained and managed onsite. There is no indication as to whether or not the target property has violated the waste discharge requirements.
• The Aspen Dairy at 10241 Edison Avenue had a cleanup and abatement order issued for it that was identical to that issued for Heritage Dairy, per the CAWDS database. There is no indication as to whether or not the target property has violated the waste discharge requirements.
• Crossroad Classic Mustang at 12421 Riverside Avenue, Unit B, Mira Loma, California, was also issued a cleanup and abatement order, per the CAWDS database. There is no indication as to whether or not the target property has violated the waste discharge requirements. 6069
Hazards Rich Haven Specific Plan - Draft EIR
5.5-4 Michael Brandman Associates
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc • An unnamed facility located at 3176 Pony Drive reported a release of muratic acid on September 19, 2002. The release occurred as a result of a container being crushed inside a City trash truck. No other information regarding this site was identified in the listing. • The Simon Koolhaas Dairy at 14717 Haven Avenue is permitted for Underground Storage Tanks (USTs) and as a Hazardous Material Handler, Underground Tank Only. • The Martin Dairy at 10129 Edison Avenue is permitted as an Agricultural Hazardous Material Handler.
• The following sites appeared on the CORTESE database as having contaminated public drinking water wells, for which clean up and abatement orders were issued: Simon Koolhaas Dairy (14717 Haven Avenue), Martin Dairy (10129 Edison Avenue), Aspen Dairy (10241 Edison Avenue), Westra Dairy Farms (11009 Eucalyptus Avenue), Crossroad Classic Mustang (12421 Riverside Avenue, Unit B, Mira Loma, California). • LUST: The Leaking Underground Storage Tank (LUST) Information System database listed the Westra Dairy Farms (11009 Eucalyptus Avenue) as a facility that had a known release from a UST.
• The Dykstra Bros. Dairy (11091 E. Edison Avenue) is known to have two historical USTs.
This facility is also known to have obtained a San Bernardino County permit as a Hazardous Material Handler.
• The AG-J&J Cattle Co. (11250 E. Edison Avenue) has one reported UST location, and has a San Bernardino County permit as a Hazardous Material Handler. • The Westra Dairy (11009 Eucalyptus Avenue) is reported as having a LUST, case closed April 24, 2000.
• The Department of Health Services conducted a California State Radon Survey, and found that radon gas is not an issue at the project site or in the project area. • No federal National Priorities List (NPL), proposed NPL, Comprehensive Environmental Response and Cleanup Liability Information System (CERCLIS), Resource Conservation and Recovery (Act) Information System (RCRIS), or Emergency Response Notification System (ERNS) facilities are located within one mile of the dairy property.
The Phase I ESAs for the project site offered the following conclusions:
• Due to past use of the project site as a dairy farm and hog farm, the potential exists for elevated soil organic levels and the associated generation of subsurface methane gas. 6070
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-5
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc • The potential for asbestos containing materials and lead-based paint on the project site exists because of some structures built before 1978.
• Based on the past and present agricultural usage of portions of the site, the potential exists for the presence of organic pesticides within the onsite soils. Soil samples should be collected and analyzed for organic pesticides in order to screen for their presence. • Several homes present on the project site reportedly use onsite sewage disposal systems. • The residences and other structures onsite may contain lead-based paint and asbestoscontaining materials. • Water supply wells were identified onsite, and it is necessary to verify that they have been properly abandoned.
• A 500-gallon diesel fuel aboveground storage tank (AST) is onsite, and should be deactivated and properly disposed of in conjunction with the site development activities. • A debris pile with improperly disposed of waste oil was observed onsite. • A concrete wastewater collection sump and associated underground water distribution piping, as well as an abandoned manufactured home are onsite.
• A Southern California Edison transmission line exists onsite with triple high-tension lines, which may impose some restrictions on development.
Based on the findings of the Phase I ESAs described previously, several methane studies were conducted for the properties that were used as dairies. Out of the 96 gas probes that were installed as a part of the methane studies, only 3 revealed elevated methane concentrations. These methane studies contained the following recommendations:
• Careful clearing, grubbing, segregation, and stockpiling or disposal of the near surface organicrich soils at the site prior to the initiation of mass grading activities should occur. • Identification and segregation/stockpiling or disposal of deeper soils which contain elevated levels of organic material should be conducted.
• Soils with organic contents in excess of 0.4 percent should not be placed as “deep” fill.
Ideally, soils with significant levels of organic material should be placed in open areas within approximately two feet of the finished ground surface.
• Soils with organic contents in excess of 2 percent should typically not be placed as structural fill—even at shallow depths. The project geotechnical engineer should provide more specific recommendations in this regard.
6071
Hazards Rich Haven Specific Plan - Draft EIR
5.5-6 Michael Brandman Associates
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc No additional investigation of the project site was recommended.
Other Risk Management Issues
Additional hazards that potentially affect the project site include vector control issues associated with existing dairy operations, and electromagnetic fields associated with electrical lines crossing the project site. These conditions are discussed below.
Vector Control. The project site is contained within the historic San Bernardino Agricultural Preserve, which has been home to one of the largest dairy cattle populations in the world. The combined dairy operations in this area have resulted in the generation of millions of tons of manure each year. It is estimated that there are 2 million tons of manure stockpiled within that area. As a result of manure stockpiling, there has been an increase in the fly population. To control the increasing fly population, chemical treatments are typically used. The West Valley Mosquito and Vector Control District promotes the practice of routine application of adulticiding chemicals, in the absence of the ability to practice proper composting. However, the continued use of these chemicals has resulted in minor to severe resistance in the adult fly populations.
Activities that would increase the potential for standing water, especially during the summer months, have the potential to increase the mosquito population. As pesticides are used to control the increasing fly population, herbicides are also used by dairies to control plant and algae population in the numerous dairy manure ponds and water ponds.
Electrical Power Facilities/Transmission Lines and Electromagnetic Fields. Southern California Edison (SCE) provides electrical services to the City and the surrounding areas.
The SCE Mira Loma substation is located immediately east of Mill Creek Avenue adjacent the project site. SCE high-voltage transmission line right-of-ways (SCE Corridor) appear at several locations onsite containing high Kv electrical transmission lines. Long-term direct exposure to electric and magnetic fields (electromagnetic fields [EMF]) has been identified as a possible risk to human health.
Electric fields are produced in electrical lines as a result of voltage applied to wiring, and are measured in volts per meter (V/m) or kilovolts per meter (Kv/m). Electric field strengths greatly diminish with distance from the source and many structures including trees and houses shield these fields. Most exposure to residential electric fields is the result of internal household appliance use. Magnetic fields are the result of the movement (current) of electricity. These fields are measured in Gauss; however, this measure is extremely large, and fields from electrical lines are generally referred to in milligaus (mg). As with electric fields, magnetic field strengths decrease dramatically with distance from the source; however, 6072
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-7
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc structures such as trees or houses, unlike electrical fields, do not shield magnetic fields.
Exposure to EMFs from power lines or electrical substations is typically in the extremely low frequency (ELF) range of the electromagnetic spectrum.
Within the project site, possible concern with EMFs resides with the major SCE power line corridor that traverses the site diagonally between Planning Areas 17 (a, b) and 20, the SCE substation immediately east of Mill Creek Avenue, and the types of uses planned within or directly adjacent to the corridor and/or substation. No U.S. federal agency has yet set ELF EMF standards. Presently, neither the State nor the County of San Bernardino has provisions or codes regulating development near major transmission lines or substations. The NMC Final EIR identifies setback requirements for educational facilities from high-voltage lines.
Ontario Airport Operations
The project site was originally estimated to be within two miles of Ontario International Airport (ONT), which is the criteria set forth in the CEQA Guidelines thresholds. This standard was used because an airport land use plan has not been adopted. Upon further investigation, the airport runways are more than two miles from the northern end of the project site along E. Riverside Drive.
The 1992 General Plan discusses current and future operations at ONT. According to the 1992 General Plan, the project site does not directly lie within the flight path of ONT. Aircraft approach ONT from the east and depart to the west, and do not fly over the general project area. The Chino Airport is located approximately 4 miles southwest of the project site.
Existing Regulations and Standard Conditions:
The City of Ontario Municipal Code Section 9-1.3330 includes Environmental Performance Standards that require: “The use, handling, storage, and transportation of combustibles and explosives shall comply with applicable provisions of the Uniform Fire Code, the City of Ontario Hazardous Waste Ordinance and all other local, state and federal regulations.”
5.5.3 - Thresholds of Significance
According to the Initial Study, the project could have a significant effect on the environment if it would:
• Create a significant hazard to the public or the environment through the routine transport, use, or disposal of hazardous materials.
• Create a hazard to the public or environment through reasonably foreseeable upset and accident conditions involving the release of hazardous materials into the environment. 6073
Hazards Rich Haven Specific Plan - Draft EIR
5.5-8 Michael Brandman Associates
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc • Be located on a site which is included on a list of hazardous materials sites compiled pursuant to Government Code Section 65962.5 and, as a result, would it create a significant hazard to the public or the environment.
• If the area was located within an airport land use plan, or where such a plan has not been adopted, within two miles of a public airport, result in a safety hazard for people that reside or work in the project area.
As previously referenced, the NMC Final EIR referenced distance setbacks developed by the State Department of Education for educational facilities from high-voltage transmission lines. Although these requirements apply only to educational facilities, the NMC Final EIR suggested that they could be applied to residential development. These setback distances are as follows: 100 feet from a 50-133 Kv line; 150 feet from a 220-230 Kv line; and 350 feet from a 500-550 Kv line. However, the State Department of Education revised policy in 2003 allows school districts to encroach within these setbacks based upon specific findings made in an EMF Management Plan.
5.5.4 - Project Impacts
The proposed project would have the potential to pose various hazards. Following is a discussion of the project impacts that correspond to the thresholds of significance previously identified in Section
5.5.3. Hazardous Materials
Short-Term Construction Impacts
In the short term, the proposed project will involve storing limited quantities of petroleum products onsite during construction-related activities. With the mandatory compliance of the City’s Environmental Performance Standards (City of Ontario 2000), the proposed project will not create a health hazard or use, produce, or dispose of materials that pose a hazard to human, animal, or plant populations within the project area. The Environmental Performance Standards are contained in the City’s Municipal Code, Article 33, Section 9-1.3300. No impact from the temporary storage of hazardous materials during the construction phase is anticipated.
As previously referenced, potential impacts from exposure to lead-based paints and asbestos from demolition activities has the potential to occur. The Phase I ESA concluded that potential impacts related to asbestos exposure and lead-based paint exist, due to the existence of older residences and structures onsite. Because the construction dates for the dairy related structures are estimated and are close to the cut-off date as referenced in the NMC Final EIR, and because it is highly likely that some 6074
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-9
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc structures were constructed prior to 1979, given the historic use of the property, it is assumed for the purposes of this analysis that all structures located on the project site were constructed prior to 1978.
Long-Term Operational Impacts
The proposed project introduces new land uses within the project area: residential, commercial, and recreation. Hazardous materials commonly associated with residential use include household cleaning and janitorial products, herbicides, insecticides, and solvents. Residential handling and disposal of hazardous materials is regulated at the federal, state, and local levels.
The proposed project provides for the development of regional commercial uses. Commercial uses that could be developed include large-scale retail commercial uses such as garden supply, furniture warehouses, discount centers, retailers, and other similar uses. Commercial development could also include professional offices, entertainment, dining, hotel, and conference facilities, supporting retail sales, product exhibition, art galleries, financial institutions, restaurants, health clubs, personal services, day-care, and professional offices. Use and storage of hazardous materials associated with allowed commercial uses will occur as a result of project implementation. In order to minimize risks to life and property, the proposed project will be required to demonstrate compliance with all applicable federal, state and local laws and regulations governing the handling, transport, treatment, generation and storage of hazardous materials.
Colony High School is adjacent to proposed single-family residential uses within Planning Areas 2, 3, 5 and 6 on the project site. Hazardous emissions or hazardous or acutely hazardous materials, substances, or waste will not intentionally be emitted. Use and storage of hazardous materials on the project site will adhere to all applicable regulations, as previously cited.
Generation and use of hazardous materials by residential, commercial, and light industrial usage within the project site is considered to have a less than significant impact due to the mandatory compliance with the City’s Environmental Performance Standards (City of Ontario 2000). The Environmental Performance Standards are contained in the City’s Municipal Code, Article 33, Section 9-1.3300.
Methane in Manure and Organic Soils
Surface organic residue (e.g., manure and other organic deposition) within the soils may remain after discontinuation of dairy operations and, in some instances, after clearing and grading. The potential for possible exposure of new development and human populations to explosive concentrations of methane released from such soils was investigated in the Phase I ESAs and methane studies. While 6075
Hazards Rich Haven Specific Plan - Draft EIR
5.5-10 Michael Brandman Associates
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc the incidence of methane gas was low, this is a potentially significant impact due to the explosion hazard in a soon-to-be highly populated area.
Vector Control
Development of the proposed project will systemically reduce the volume of standing water and other sources associated with the dairies, where mosquitoes can breed.
With the abundance of manure and the presence of stagnant water, these populations may continue to breed during the dairy transition to urban uses, and buildout of the Chino/Ontario areas. Control of these populations can be achieved with non-chemical methods (i.e. mechanical methods) and the use of pesticides. With proper vector control practices, health and safety impacts are not expected to be significant. Past and present uses of pesticides and herbicides in agricultural operations can leave measurable residues in soils. The Phase 1 ESAs for the project site addressed the possible presence of chemical residues in the soil and concluded that future uses of the project site would not be adversely affected by past agricultural use. Hazard impacts on the project site from vectors and past agricultural use are considered less than significant.
Electromagnetic Fields
Within the project site, possible concerns with EMFs are associated with the high-voltage electrical transmission lines that cross the project site. The NMC Final EIR identifies setbacks for educational facilities from high-voltage lines and indicates that could be applied to residential development. No U.S. federal agency has yet set Extremely Low Frequency EMF standards. Presently, no state, county, or City has provisions or codes regulating development near major transmission lines or substations. In addition, SCE does not have published standards regulating development adjacent to high-voltage transmission line rights-of-way (Southern California Edison 2005).
The proposed land use plan locates residential areas in Planning Areas 17 (a, b) and 20 adjacent to the major high-voltage line easement that diagonally traverses the project site. Because 1) the setback standards previously identified apply to educational facilities and are not required to be applied to residential development, 2) no definitive standards have been established by a federal agency, and 3) neither the City nor SCE have established setback requirements, potential impacts resulting from the proximity to the high-voltage transmission lines are considered less than significant.
Hazardous Materials
According to the Phase I ESAs prepared for the project, the various databases indicate that only one site lying near or within the project site boundaries exhibits the presence of hazardous materials. This 6076
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-11
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc is the Martin Dairy at 10129 Edison Avenue that has a San Bernardino County Permit as an Agricultural Hazardous Material Handler. The site experienced an isolated spill event in July 1999.
The Phase I ESAs concluded that the conditions associated with this individual site did not present a hazard for the project site.
No evidence of any significant soil and/or groundwater contamination has been identified within the overall project site, and the site is not identified as within the Border Zone of a Contaminated Property.
Ontario Airport Operations
As previously stated, ONT is not within 2 miles of the project site. The 1992 General Plan discusses current and future operations at ONT and describes impacts associated with those operations.
Examination of this information reveals that the project site does not directly lie within the flight path of ONT and that no impacts are anticipated related to penetrations of air space, safety zones, or other protection areas. The only anticipated impact from ONT would be sporadic occurrences of aircraft flying over the general area in a southeasterly direction away from the Airport. At this distance, the maximum heights of the proposed structures would not penetrate any of the building height restrictions contained in the Federal Aviations Administration’s Part 77 regulations.
5.5.5 - Cumulative Impacts
Implementation of the proposed plan will provide for a variety of residential, commercial, and open space related uses. In general, the types of uses allowed do not include those that would result in the generation of substantial quantities of hazardous wastes or toxic materials. Compliance with federal, state, and local regulations concerning the handling, transport, and disposal of hazardous materials and wastes would reduce impacts to less than significant levels. As related projects in the project vicinity will be required to mitigate their own hazardous materials impacts, no significant cumulative impacts related to hazardous materials are anticipated.
With cumulative development within the ONT vicinity, additional populations could be exposed to some level of risk associated with aircraft activities and hazards. However, safety zones have been established to protect future uses and reduce hazards to an acceptable level of risk, and future development could be subject to review by the Airport Comprehensive Land Use Plan (ACLUP) to assure compatibility, should an ACLUP for ONT be developed. No significant cumulative impact is anticipated.
6077
Hazards Rich Haven Specific Plan - Draft EIR
5.5-12 Michael Brandman Associates
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc
5.5.6 - Mitigation Measures
The Risk of Upset Section of the NMC Final EIR identified mitigation measures related to hazardous materials (Mitigation measures HM-1 through HM-3) and a mitigation measure (EMF-1) related to electromagnetic fields. Mitigation measure HM-1 required the preparation of Phase 1 ESAs on all future developments in conformance with the American Society for Testing and Materials.
Mitigation measure HM-2 required documentation that structures on the project site subject to renovation or demolition from a proposed project did not contain lead-based paints or asbestos or that if these materials were present, appropriate remedial actions for lead-based paints and asbestos would be used. Mitigation measure HM-3 required projects that proposed to handle, transport, process, or store hazardous materials to comply with the policies related to hazardous materials contained in the NMC General Plan. Mitigation measure EMF-1 required residential units and education facilities to be setback from high-voltage electrical transmission lines in accordance with the California Department of Education Guidelines.
Implementation of the NMC Final EIR mitigation measures and the following recommended mitigation measures would reduce potentially significant impacts to a less than significant level.
HM-1 Prior to the issuance of permits by the City of Ontario for any structural demolition activities on the project site, the project developer will be required to submit documentation to the City of Ontario Building Department that asbestos and lead-based paint issues are not applicable to their property or that appropriate remediation actions will be undertaken to correct any lead-based paint or asbestos issues, in conformance with the regulations of the South Coast Air Quality Management District and the State of California, Division of Occupational Health and Safety.
HM-2 Subsequent to grading activities, testing for the presence of methane in the soil shall be performed. This testing shall conform to applicable City of Ontario standards. If methane is detected, mitigation would include the installation of under-slab methane vents, methane barrier, and sealing utilities in locations where they enter a structure and penetrate the methane barrier.
HM-3 Post-grading methane gas investigation should take place near the former Scritsmier Hog Ranch (13571 Haven Avenue) where subsurface methane levels exceed 5,000 ppm. A passive vent system and gas membrane beneath the floor slab should be installed, along with utility trench dams and conduit seals.
HM-4 Careful clearing, grubbing, segregation, and stockpiling or proper disposal of the near surface organic-rich soils at the site prior to the initiation of mass grading activities should occur.
6078
Rich Haven Specific Plan - Draft EIR Hazards
Michael Brandman Associates 5.5-13
H:\Client (PN-JN)\0116\01160021\DEIR\01160021_Sec05-05_Hazards.doc HM-5 Identification and segregation/stockpiling or proper disposal of deeper soils which contain elevated levels of organic material should be conducted.
HM-6 Prior to approval of a discretionary permit or approval for development of proposed residential uses on the Hillardis property, such as a parcel map or tentative tract map, a Phase 1 Environmental Site Assessment (ESA) shall be conducted and the results of that ESA implemented. The Phase 1 ESA shall be provided to the City of Ontario and shall be included in any CEQA analysis prepared in connection with the consideration of a discretionary approval for development of the eastern half of the project site.
5.5.7 - Level of Significance After Mitigation
Mitigation measure HM-1 requires implementation prior to permit issuance. This eliminates the potential for construction-related activities to commence without the benefit of the recommended mitigation measure and would prevent any building materials that may contain lead and/or asbestos from being released into the environment. Therefore, the effects will be less than significant.
Mitigation measures HM-2 through HM-5 should be implemented between the site preparation phase and the building construction phase and would prevent methane gas if present in the soil, from penetrating any of the structures built on the project site. The effects would be less than significant.
Mitigation measure HM-6 would require the preparation of a Phase 1 ESA on the Hillardis property that would determine the presence or absence of any hazardous materials on that portion of the project site prior to the approvals of any development permits. Because all necessary Phase I ESAs have been prepared, and mitigation measures developed, the effects would be less than significant.
With the incorporation of the recommended mitigation measures, implementation of the proposed project would result in less than significant impacts related to hazardous materials. 6079
6080
RICH-HAVEN SPECIFIC PLAN
ONTARIO, CALIFORNIA
HYDROLOGY REPORT
PREPARED FOR:
[Name]
[Address1]
[Address2]
[phone]
Date Prepared: September, 2022
Date Revised:
PREPARED BY:
X Engineering & Consulting, Inc.
6 Hutton Centre Drive, Suite 650
Santa Ana, California 92707
949.522.7100
Project Manager: Puneet Comar
Project Number: 142-001
6081
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 1
This report was prepared by or under the supervision of the undersigned registered civil engineer who attests to the technical information contained herein. ___________________________________ _____________
Puneet Comar, PE, QSD Date
6082
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 2
TABLE OF CONTENTS
I. INTRODUCTION ...............................................................................................................................4 II. RICH-HAVEN WATERSHED ..............................................................................................................5 PROPOSED DRAINAGE FACILITIES .................................................................................................5
1. Haven Avenue Storm Drain.........................................................................5
2. Mill Creek Avenue Storm Drain ..................................................................6
3. Milliken Avenue Storm Drain........................................................................6 STORM DRAIN FACILITIES DRAINAGE AREA .................................................................................6 LAND USE ........................................................................................................................7 III. HYDROLOGY AND HYDRAULICS .................................................................................................10 2012 MPOD STUDY ......................................................................................................................10 STUDY OBJECTIVES ......................................................................................................................10
1. Hydrology analysis......................................................................................10
2. Peak flow mitigation...................................................................................10
3. Hydraulic Analysis.......................................................................................10 HYDROLOGY ANALYSIS ...............................................................................................................10
1. Hydrologic Study Approach .....................................................................10
2. San Bernardino County Hydrology Methodology ..................................12
3. Implementation of Rational Method Analysis.........................................13
4. Hydrologic Study Criteria...........................................................................13 PEAK FLOW RATE MITIGATION ANALYSIS ...................................................................................13 HYDRAULIC ANALYSIS..................................................................................................................13 IV. FINDINGS/RECOMMENDATIONS.................................................................................................14 HYDROLOGY ANALYSIS ...............................................................................................................14
1. Modeling approach...................................................................................14
2. Haven SD .....................................................................................................15
3. Mill Creek SD................................................................................................15
4. Milliken SD ....................................................................................................16 PEAK STORM FLOW RATE MITIGATION ANALYSIS ......................................................................16
5. Haven SD .....................................................................................................16
6. Mill Creek SD................................................................................................16
7. Milliken SD ....................................................................................................17 HYDRAULIC ANALYSIS..................................................................................................................17
8. Haven SD .....................................................................................................17 6083
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 3
9. Mill Creek SD................................................................................................17
10. Milliken SD ....................................................................................................18 V. CONCLUSION ...............................................................................................................................18 VI. REFERENCES...................................................................................................................................18
FIGURES
Figure 1: Rich-Haven Specific Plan Vicinity Map
Figure 2: Proposed Rich-Haven Specific Plan- Proposed land uses and Planning Area Designation
APPENDICES
Appendix A: Exhibits and Hydrology Map
Appendix B: Hydrology Calculations
Appendix C: Hydraulic Calculations
6084
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 4
I. INTRODUCTION
The Rich-Haven Specific Plan includes approximately 584.2 gross acres of land in the southwestern portion of the City of Ontario, within the Ontario Ranch (formerly known as ‘New Model Colony’ or NMC). The project site, hereafter referred to as Rich-Haven, is bounded to the north by Riverside Drive, Colony High School, and SCE Mira Loma substation, to the east by Hamner Avenue, to the West by Haven Avenue, and to the south by Old Edison Road. Under the specific plan, Rich-Haven is to be developed as a cohesive community that incorporates diverse land uses that include residential of various densities, industrial, mixed-use, open space non recreation, and open space parkland (See Figure 1 herein).
Figure 1. Rich-Haven Specific Plan Vicinity Map (Source: City Council Approved Specific Plan Amendment (File No. PSPA19-006): May 18, 2021 Resolution No’s 2021-047) The Rich-Haven Specific Plan was first approved by the City Council on December 4th, 2007, and has since been amended multiple times that oversaw changes in its planned land uses and coverage. The latest amendment was adopted on May 18th, 2021; notable changes of which 6085
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 5
include an increase of 72.1 acres in the project’s land coverage and changes in planned land uses that reflect the current market trend. These changes redefine the hydrologic patterns of the project site, which was previously evaluated in the 2012 City of Ontario’s Master Plan of Drainage (hereafter, MPoD, unless stated otherwise) for sizing and planning of storm drain facilities. It is therefore important to validate the adequacy of the planned and constructed master-planned storm drain facilities in supporting developments within the amended Rich-Haven Specific Plan area. Consequently, the purpose of this study is to assess the hydrologic changes of the project and its implications on the planned storm drain facilities, using the MPoD study as comparison baseline (See Exhibit 1 in Appendix A).
II. RICH-HAVEN WATERSHED
According to the 2012 MPoD, The Rich-Haven Specific Plan area is located within Drainage Area X, which covers approximately 4.5 square miles (2,880 acres). Drainage Area X is tributary to the County Line Channel, which is owned and maintained by the San Bernardino County Flood Control District and runs along the southerly edge of Ontario Ranch.
Rich-Haven is located within the northeastern portion of Drainage Area X, which is described as the following land area. The upstream or study area of drainage area X is bounded to the north by SR60, to the east by Milliken/Hamner Avenue, to the west by the approximate westerly edge of landscape buffer of Haven Avenue, and to the south by old Edison Avenue, covering a total of 1,062 acres (See Exhibit 2 in Appendix A). Drainage among this sub watershed is further divided into three separate subareas, the drainage of each subarea will be intercepted and conveyed by the regional backbone drainage system as outlined below.
PROPOSED DRAINAGE FACILITIES
Drainage from the Rich-Haven project area will be conveyed by three main planned backbone storm drain lines, namely: 1) Haven Avenue Storm Drain, 2) Mill Creek Avenue Storm Drain, and 3) Milliken Avenue Storm Drain, all of which drain from north to south and connect to the County Line Channel (See Exhibit 2 in Appendix A). Description of each backbone storm drain lines and its current implementation status are outlined as follows.
1. Haven Avenue Storm Drain
Haven Avenue Storm Drain (hereafter, Haven SD) is a network of storm drain lines 48” to 84”in size, with a mainline (HAVN-X-1) that runs north from Bellegrave Avenue to Riverside Drive along Haven Avenue and branches to storm drain line (HAVN-X-2, -X3, and -X4) and several unnamed laterals that extend from planned/future development within Rich-Haven (See Figure 2 under Section C for Planning Area (PA) designation).
Storm Drain Line Location Construction status as of writing HAVN-X-1 Runs north from Bellegrave Avenue to
Riverside Drive along Haven Avenue
Partially constructed to southerly lot
line of Rich-Haven Planning Area 3
(PA-3) (Public Park). See Figure 2.
HAVN-X-2 Branches westerly off HAVN-X-1 in Ontario
Ranch Road
Constructed
HAVN-X-3
(Twinkle Storm Drain)
Branches from HAVN-X-1 through PA 5
and drains portions of PA 1, 2, 3, 4, and
Colony High school
Constructed to north lot line of
Rich-Haven PA 5, not constructed
north of PA 5
6086
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 6
Storm Drain Line Location Construction status as of writing HAVN-X-4 Branches easterly off HAVN-X-1 in Chino
Avenue and drains portion of PA 1
Not Constructed
2. Mill Creek Avenue Storm Drain
Mill Creek Avenue Storm Drain (hereafter, Mill Creek SD) is a network of storm drain pipes ranging in size from 48” to a 10’ x 8’ box , with a mainline (MLCR-X-1) that runs north from Bellegrave Avenue to Chino Avenue along Mill Creek Avenue, and extends to the east in Chino Avenue. MLCR-X-1 branches to MLCR-X-4, -5, and -6 and minor laterals that extend from planned/future development within Rich-Haven along Mill Creek Avenue (See Figure 2 under Section C for Planning Area (PA) designation).
Storm Drain Line Location Construction status as of writing MLCR-X-1 Runs north from Bellegrave Avenue to
Chino Avenue along Mill Creek Avenue
and turns east along Chino Avenue
Constructed north from Bellegrave
Avenue to Eucalyptus (outside of
Rich-Haven limit)
MLCR-X-4 Branches easterly off MLCR-X-1 in Ontario
Ranch Road and drains PA 7
Constructed
MLCR-X-5 Branches westerly off MCLR-X-1 in Ontario
Ranch Road and drains PA 6
Constructed
MLCR-X-6 Branches easterly off MLCR-X-1 in SCE
access road and drains SCE Mira Loma
Substation
Not Constructed
3. Milliken Avenue Storm Drain
Milliken Avenue Storm Drain (hereafter, Milliken Avenue SD) is a main line storm drain that varies in size from 36” to 54” that drains south from Ontario Ranch Road to Bellegrave Avenue along Hamner Avenue (also known as Milliken Avenue). Storm drain laterals extend from planned development within a minor portion of the southeastern area of Rich-Haven.
Storm Drain Line Location Construction status as of writing MLKN-X-1 Runs north from Bellegrave Avenue to
Riverside Drive along Milliken/Hamner
Avenue
Constructed
STORM DRAIN FACILITIES DRAINAGE AREA
The tributary drainage area for each regional backbone drainage system per 2012 MPoD (Master Plan of Drainage) is summarized in the following table:
Drainage System Tributary drainage area (MPoD 2012)
Haven Storm drain 352.2 acres
Mill Creek Storm drain 659.9 acres
Milliken Storm drain 50.0acres
6087
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 7
LAND USE
The current designated land uses within the Rich-Haven area are outlined in the proposed RichHaven Specific Plan (See Figure 2 herein). These updated land uses are compared to the land uses approved by the City Council under the 2010’s City of Ontario’s Revised Land Use Plan, which were used as the basis of hydrologic study for the 2012 MPoD.
Figure 2. Proposed Rich-Haven Specific Plan- Proposed land uses and Planning Area Designation
6088
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 8
A summary of the land use change is shown as follows, with references to the planning areas within the Rich-Haven area (also See Exhibit 1 in Appendix A).
PLANNING AREA/
PROJECT NAME
LAND USES
2010 CITY’S REVISED LAND USE
PLAN
PROPOSED RICH-HAVEN SPECIFIC
PLAN LAND USES
PA-1A Residential (2.1-5DU/AC) Residential (0-5 DU/AC)
PA-1B Residential (2.1-5DU/AC) Residential (5.1-12DU/AC) PA-1C Residential (2.1-5DU/AC) &
Commercial
Residential (12.1-25DU/AC)
PA-2 Open Space- Non Recreation Open Space- Non Recreation PA-3/ Sports Park Public Park & Open SpaceNon RecreationPublic Park PA-4A/ MCBC- Colonial Open Space- Non Recreation Light Industrial PA-4B/ Colonial Residential (2.1-5DU/AC) Residential (5.1-12DU/AC) PA-4C Residential (11.1-25DU/AC) Public Park
PA-5A and -5C/
Neuhouse
Residential (11.1-25DU/AC) Residential (12.1-25DU/AC)
PA-5B/ MCBCVanderEykResidential (11.1-25DU/AC) Light Industrial PA-5D/ VanderEyk Residential (11.1-25DU/AC) Residential (12.1-25DU/AC) PA-5E and -5F/ SCE
Easement
Open Space- Non Recreation Open Space- Non Recreation
PA-6A/ Canvas Park Mixed Use Residential – Stand Alone
PA-6B/ Randall North Mixed Use Light Industrial
PA-6C Open Space- Non Recreation Open Space- Non Recreation PA-6D/ Randall North Open Space- Non Recreation Commercial PA-7A/ Visser Demody Mixed Use Light Industrial
PA-7B/ Visser Richland Mixed Use Commercial
PA-8A/ Community
College & Wood
Investments
Mixed Use Mixed Use
6089
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 9
PLANNING AREA/
PROJECT NAME
LAND USES
2010 CITY’S REVISED LAND USE
PLAN
PROPOSED RICH-HAVEN SPECIFIC
PLAN LAND USES
PA-8B/ Pietersma Mixed Use Residential - Stand Alone
Commercial
PA-9A/ Regions South Mixed Use & Open SpaceNon RecreationResidential - Stand Alone, Open Space- Non Recreation, &
Commercial
PA-9B/ Randall South Mixed Use & Open SpaceNon RecreationResidential - Stand Alone, Open Space- Non Recreation, &
Commercial
6090
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 10
III. HYDROLOGY AND HYDRAULICS
2012 MPOD STUDY
The ultimate condition hydrology of the Rich-Haven area was evaluated in the 2012 City’s MPoD, with designated land uses that align with the Revised Land Use Plan adopted by the City Council in January 2010 (Refer to Appendix A, Exhibit 1).
However, the proposed land uses in some planning areas under the proposed Rich-Haven Specific Plan are generally denser or more impervious than the previously planned land use under the City’s 2010 Revised Land Use Plan, such as the conversion of a low-density residential land use to high-density residential land use (See Section II.C- Land Use). Land use with more impervious areas typically generate higher peak flow with a shorter time of concentration. In addition, the tributary drainage areas of the master-planned regional backbone storm drainage systems have also changed since the MPoD study. Altogether, these changes present important implications in the planning and sizing of storm drain facilities, which necessitates a hydrology and hydraulic study.
STUDY OBJECTIVES
The overarching goal of this study is to ensure that there will be no significant adverse impacts to down stream storm drain facilities within the study area as a result of this project.
Towards this goal, three objectives are further scoped, in order, as below:
1. Hydrology analysis
- Reassess the hydrologic characteristics of the Rich-Haven area based on its latest proposed land uses and changes in the master-planned storm drain watersheds (Haven SD, Mill Creek SD, and Millken/Hamner SD watersheds).
2. Peak flow mitigation analysis
- Determine the properties within Rich-Haven that may require peak flow mitigation. - Designate the allowable mainline peak flow within each storm drain mainline at storm drain connection point for each property.
3. Hydraulic Analysis
- Based on the preceding analyses, identify the storm drain mainline(s) that requires further hydraulic analysis.
- Analyze the proposed/existing storm drain for hydraulic capacity as needed
HYDROLOGY ANALYSIS
The following subsection outlines the hydrologic study components.
1. Hydrologic Study Approach
6091
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 11
A main objective of this study is to update the 2012 MPoD hydrology analysis with updated inputs that reflect the latest Rich-Haven Specific Plan and any changes that may have occurred.
To ensure accurate comparison between this study and the 2012 MPoD study, a detailed review of the latter’s hydrologic calculations was conducted to identify and preserve information that remains unchanged since the was completed. These include hydrologic data for existing development that were included as part of the 2012 MPoD study, planned storm drain facilities and its location.
Hydrologic parameters from planning areas and storm drains within Rich-Haven that were constructed, and changes in tributary area of the regional storm drains since the MPoD study are also incorporated into this study to reflect the latest conditions of the Rich-Haven to the maximum extent possible.
The following table summarizes the items in the 2012 MPoD that were reused in this study.
Item Description
Hydrologic Node 5115
Confluenced Peak Flow rate, Max Loss Rate, and associated Tc from upstream-most drainage area of Rich-Haven Drainage Area
Hydrologic Node 5210 Confluenced Peak Flow rate, Max Loss Rate, and associated Tc from the Mira Loma SCE Substation Drainage Area
Hydrologic Nodes 5115,
5141, 5215, 5248, 5300,
5305, and 5330
Hydrologic nodes for the Mill Creek Storm Drain Drainage Area Hydrologic Nodes 4070,
4080, 4075, 4120, 4170,
4171, and 4200
Hydrologic nodes for the Haven Storm Drain Drainage Area Hydrologic Nodes 6050 Hydrologic node for the Milliken Storm Drain Drainage Area The following table summarizes the parameters of projects within Rich-Haven area used in this study:
Item Description
Hydrologic Nodes 4070
and 4080
Confluenced Peak Flow rate, Max Loss Rate, and associated Tc at referenced node per TTM 20526, PA 1 project (Node 508 and 312, respectively)
Hydrologic Node 416
Confluenced Peak Flow rate, Max Loss Rate, and associated Tc at referenced node per TM 20530, PA 5D (Vander Eyk)
Project (Node 312)
6092
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 12
Item Description
Hydrologic Node 440 Hydrologic node at referenced node per TTM 20081, PA 6A (Regions North) project (Node 505)
Hydrologic Nodes 445,
450, and 4170
Pre-confluenced Peak Flow rate, Max Loss Rate, and
associated Tc at referenced node per TTM 20081, PA 6A
(Regions North) project (Node 5001, 5002, and 4170,
respectively)
Hydrologic Nodes 455
Pre-confluenced Peak Flow rate, Max Loss Rate, and
associated Tc at referenced node per PM19978, New Haven Commercial Development project (not part of Rich-Haven
areas) (Node 37)
Hydrologic Nodes 465
Pre-confluenced Peak Flow rate, Max Loss Rate, and
associated Tc at referenced node per TM20076, New Haven Residential Development project (not part of Rich-Haven areas) (Node 20)
Hydrologic Nodes 460
and 4171
Pre-confluenced Peak Flow rate, Max Loss Rate, and
associated Tc at referenced node per TM 20449, PA 9A
(Regions South) Project (Node 517 and 415, respectively)
2. San Bernardino County Hydrology Methodology
The hydrology methodologies accepted by the City of Ontario are documented in the San Bernardino County’s Hydrology Manual (1986) and subsequent addenda. Two methods are primarily used:
a) Rational Method
b) Unit Hydrograph Method
Peak flow and time of concentration are typically the outcomes of interest from these methods. Selection of methodology is dependent on the drainage size to be studied.
Rational method is typically used for drainage area that is approximately 1 square mile (640 acres) or less, beyond which the method may become less reliable due to the higher variation in point precipitation over a larger area. Unit hydrograph is then used for continuation of drainage study beyond 1 square mile, using the time of concentration estimated by Rational Method and area-averaged point rainfall over the entire drainage area as inputs.
The 2012 MDoP used both methods for its hydrology analysis, starting off with Rational Method for all drainage area studies, and switching to the Unit Hydrograph Method should the drainage area exceed 1 square mile.
This study adopts similar methodology basis as the MDoP, however, due to the relatively smaller drainage area of the Rich-Haven (i.e. ~644 acres for the largest sub drainage are), only Rational method is used.
6093
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 13
3. Implementation of Rational Method Analysis
The Rational Method for this study is implemented using RSBC software, 2018 version, developed by Civil Design® Corporation and Joseph E. Bonadiman and Associates Inc.
RSBC software is accepted by the County of San Bernardino for hydrologic study purposes.
The software implements the various modeling approaches of the County’s Rational Method as documented in the County’s Hydrology Manual, which includes initial subarea time of concentration estimation, subarea addition, pipe and street flow time, and confluence analysis of adjoining streams.
4. Hydrologic Study Criteria
The parameters used for this study adhere to the 100-year storm study criteria used in MDoP and are summarized as follows.
Storm Return Frequency 100-yr
1-hour rainfall depth 1.2 in
Log-Log Slope for Rational
Method Hydrology Studies 0.6
AMC Condition II
PEAK FLOW RATE MITIGATION ANALYSIS
Peak flow mitigation is typically required if the peak flow rate as determined by this report’s hydrology analysis exceeds the existing/proposed storm drain capacities. The individual developers of each planning area will be responsible for complying with mainline storm drain allowable flow rates as designated in this report or determining other methods of not adversely impacting the storm drain system capacity.
This study aims to determine an allowable peak flow Q for various planning areas, represented by the allowable peak flow at different points of the storm drain main line in relation to times of concentration, taking into account the existing and planned built-out conditions of the Rich-Haven area.
HYDRAULIC ANALYSIS
Hydraulic study of a drainage system acts as validation of the engineering design of the drainage system. This level of study typically is conducted with the availability of more detailed information, which include outputs from the preceding analyses.
Hydraulic parameters of the planned regional backbone storm drainage systems, such as the hydraulic grade line (HGL) and velocity, are shown on various approved storm drain improvement plans for the City of Ontario. The hydrologic data used for the hydraulic design of these storm drains are derived from different sources. For instance, the Haven Storm Drain hydraulic design is based upon the 2012 MPoD’s hydrologic outputs. Whereas 6094
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 14
the Mill Creek Storm Drain hydraulic design is based upon a combination of hydrologic outputs from 2007 MPoD’s hydrologic outputs and approved final engineering studies from developed planning areas within Rich-Haven, and the Huitt-Zollars Mill Creek Hydraulic Study dated July 11th, 2022, which when looked at holisitically, allows for possible reconfiguration of storm drain to accommodate field conditions and updated design constraints.
The hydraulic parameters as shown approved storm drain plans may be utilized to assess the need for conducting a, updated hydraulic analysis of the proposed storm drain system.
For example, if the peak flow along the mainline as estimated by the updated hydrology analysis remains consistently lower than the peak flow shown on the existing approved storm drain plans throughout all segments of the main lines, it can be inferred that the updated HGL will be lower than the existing HGL and any adverse impacts to the downstream storm drain(s) in the study area are not anticipated. Therefore, a hydraulic analysis of the subject storm drain is not provided in this study. However, if any of the storm drain segments is expected to convey a higher flow than shown on the existing storm drain plan, a detailed hydraulic analysis will be provided in this study to ensure that adequate capacity of the proposed storm drain to handle the updated hydrologic conditions.
The outcomes from this hydraulic analysis serve to determine the critical section along the storm drain mainline in terms of water surface elevation, which must not rise above 6” below finished surface or lip of catch basin for a 100-year storm, per the City of Ontario’s storm drain design goals.
IV. FINDINGS/RECOMMENDATIONS
HYDROLOGY ANALYSIS
1. Modeling approach
This study’s hydrology modeling approach varied slightly from that of the MPoD. The subarea addition approach, as used extensively in MPoD, is sensitive to the subarea size definition, which may either discount flow contribution of a subarea entirely or significantly amplify the estimated flow addition. This shortcoming is also acknowledged by the County’s Hydrology Manual (Section D.11, Step 5). For example, an estimated 101 cfs from 53 acres of drainage area (out of a total of 660 acres) was not accounted in the MPoD’s Mill Creek SD peak flow (within the study area) as a result of using the subarea addition approach (See Nodes 5116, 5117, 5141, 5215, 5248, 5300, and 5330 in MDoP Hydrology Calculations). While this modeling approach is generally accepted for planning level study such as Master Drainage Plan, it may not be suitable for storm drain design.
To circumvent this issue, this study used confluence analysis (County’s Hydrology Manual, Section D.8) for any major subarea flow addition to the mainline, such as flow contribution from a Planning Area. Confluence analysis is a deliberate method that estimates the peak flow contribution of two or more streams joining at a physical location but at different times of concentration. This method allows for more specific understanding of the mainline flow contribution of a particular area, from which mitigation of peak flow can be determined .
Peak flow estimated from confluence analysis is also generally higher than simple subarea 6095
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 15
addition, as the former may partially discount peak flow based on time of concentration of the adjoining streams, but never the entire flow as the latter may discount as mentioned above.
The estimated peak flow from this study is presumed to be comparable to MPoD for further analysis of the planned storm drain system.
2. Haven SD
Although the drainage delineation for Haven SD (within Rich-Haven) has changed since the MPoD study, its tributary drainage area has remained the same (353 acres vs 352 acres at node 4200). However, the peak flow generated within the Haven SD has increased from 504 cfs to 603 cfs, a 101 cfs (20%) increase, at the downstream most point of the Haven SD watershed node 4200 (See Appendix A- Exhibit 3 and Appendix B- Hydrology Calculations for more information). This increase in peak flow is attributed to the densification and increase of impervious area of PA-1B, -1C, and -4B as a result of their new proposed land uses (denser residential uses). Exceedance of MPoD’s peak flow is observed at the confluence of HAVN-X-3 and the main line HAVN-X-1. HAVN-X-3 conveys a significant stormwater flow rate (121cfs) from PA-1—including runoff from the existing detention basin at the southwest corner of Colony High School—and all runoff from PA-4B before joining the mainline.
3. Mill Creek SD
Mill Creek SD (within Rich-Haven) shares a watershed boundary with Haven SD and Milliken SD. The tributary drainage area of Mill Creek SD is reduced slightly from 660 acres to 644 acres since the MPoD study. This reduction is presumably carried over from the neighborhood edge adjustment of properties within the adjacent Haven SD and Milliken SD watershed, and the redirection of flow from PA-4B and 5C from Mill Creek SD watershed to Haven SD watershed. In the context of the large scope of the study, this acreage change is negligible.
The peak flow generated within the Mill Creek SD increased from 1,021cfs per the MPoD to 1,160cfs in this study, a 139 cfs (14%) increase, at node 5330, the downstream most point of the Mill Creek SD watershed study area (See Appendices A and B). This increase in peak flow is due to the addition of flow contribution from a portion of PA-1 that was to be conveyed by Haven SD (in 2012 MPoD) and the increase of impervious area of PA-4A, -5B, 6B, -6D, -7A, and -7B, as a result of the new proposed land uses (Industrial and commercial use). The initial exceedance of MPoD’s peak flow is observed at the joining of the storm drain lateral from PA-1 to the mainline node 5115, which propagates downstream and gradually add up with the addition of runoff from storm drain laterals from PA-4A, -5B, -6B, -7A, -7B, -8A, -8B, -9A and -9B (See Appendix A- Exhibit 3 and Appendix B- Hydrology Calculations for more information).
6096
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 16
4. Milliken SD
Milliken SD (within Rich-Haven) does not have any changes in land use, drainage area, or planned storm drain. A slightly larger area of 52 acres (vs. 50 acre in MPoD) as measured in this study’s CAD file is due to adjustment for neighborhood edge and the linework precision between the CAD drawing and its MPoD counterpart. This difference is considered negligible for drainage study of this level. The peak flow at the downstream most point of the Milliken SD is estimated at 73.3 cfs per the MPoD study node 6050.
Since the input data remains the same, the Milliken SD watershed was not studied.
PEAK STORM FLOW RATE MITIGATION ANALYSIS
Based on the hydrology analysis result, the peak flow rate from certain planning areas withinin the Haven SD and Mill Creek drainage area needs to be mitigated to ensure adequate storm water conveyance and flood protection along the mainlines upstream of the County Line Channel. The acceptable flow rate is defined by the allowable peak flow rate, Qallow, along the mainline, which is determined by an iterative modeling approach of the preceding hydrology analysis by assigning a controlled flow rate contribution from the planning area(s) that would ultimately require peak flow mitigation to prevent significant adverse impacts to the downstream storm drain facilities.
The allowable flow rate along the mainline as designated by this report shall not be exceeded when flow is added from the planning areas requiring peak flow mitigation, as supported by a confluence analysis of the main line with the adjoining stream from each planning area. Planning area-specific studies may be performed to demonstrate that no adverse impact to the storm drain system is caused.
5. Haven SD
Peak flow mitigation solutions shall be ideally implemented within PA-1, which is the upstream-most portion of the Haven SD drainage area within Rich-Haven. PA-1 contributes significant flow to the Haven SD, both directly to HAVN-X-1 and indirectly through HAVNX-3. The large land area of PA-1 also provides for flexible peak flow mitigation options, as compared to the planning areas downstream, which are either under construction or builtout. In addition, the existing detention basin at the southwest corner of Colony High School, is an ideal peak flow mitigation solution if remaining. Refer to Exhibit 3 in Appendix A for locations of potential flow mitigation solutions and allowable flowrates along the Haven SD mainline.
6. Mill Creek SD
Peak flow rate shall be mitigated within PA-4A, -5B, -6B, -7B, -8A, -8B, -9A and -9B, which are deemed to be the main contributors to the increase in peak flow along the mainline. 6097
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 17
Refer to Exhibit 3 in Appendix A for location of potential peak flow mitigation facilities and allowable flow rates in the Mill Creek SD mainline.
7. Milliken SD
Peak flow mitigation is not required for Milliken SD, considering that the Milliken SD watershed remains unchanged since the MPoD study.
HYDRAULIC ANALYSIS
8. Haven SD
Based on the existing approved storm drain plans for Haven SD and the allowable flow rates from the preceding peak flow mitigation analysis, it is observed that the allowable flow rates are consistently lower than the flow rates shown on the existing approved storm drain plans throughout all segments of the Haven SD, as summarized in the following table (See Exhibit 4 in Appendix A).
Stationing on
SD
Node on
Exhibit 3
Q in Storm Drain Plan Allowable Q in
Exhibit 3
114+75.39 4070 160 cfs 73 cfs
108+13.69 4075 189 cfs 100 cfs
98+15.73 4120 422 cfs 250 cfs
74+85.76 4170 504 cfs 411 cfs
62+13.65 4171 504 cfs 504 cfs
61+34.99 4200 553 cfs 504 cfs
Based upon the above allowable Q, the existing/proposed Haven SD will have capacity to adequately convey the updated flow.
9. Mill Creek SD
As certain segments of the Mill Creek SD will be experiencing higher peak flow as compared to the approved storm drain plans regardless of the implementation of peak flow mitigation (See Exhibit 3 in Appendix A), a detailed updated hydraulic analysis is provided in this report for Mill Creek SD.
Hydraulic analysis of Mill Creek storm drain is an extension to the supporting study for the 2022 Mill Creek Storm Drain Delta 4 (M-1183) prepared by Huitt-Zollars Inc, for the construction of Mill Creek storm drain segment between Ontario Ranch Road and Chino Avenue to incorporate the whole Rich-Haven area. The input file for WSPGW—a commercial software package for analyzing hydraulic capacity of storm drains—from Huitt-Zollars Inc’s study was utilized and modified with peak flow output as yielded by this study’s hydrology analysis.
The hydraulic analysis of the Mill Creek SD was conducted using the Qallow as determined in the preceding peak flow mitigation analysis. Peak flow contribution from each planning 6098
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 18
area requiring mitigation is determined as the difference between the peak flow immediately upstream of the point of confluence and the Qallow at the point of confluence.
The hydraulic grade line (HGL) analysis indicates that the Qallow is adequate in ensuring the adequate flood protection within the mainline upstream of County Line Channel (See Appendix A- Exhibit 5 and Appendix C-Hydraulic Calcs). Any deviation that causes exceedance of the Qallow shall be supported by a similar analysis that ensure less than significant impacts to the storm drain facilities.
10. Milliken SD
Since peak flow mitigation is not required for Milliken SD, a hydraulic analysis of the storm drain is not conducted.
V. CONCLUSION
This report has determined where peak storm flow rates in mainline storm drain systems have increased with the updated Rich-Haven Specific Plan land uses and watersheds. Furthermore, it has also be determined where the existing/proposed storm drain facilities will have capacity deficiencies due to the proposed project. To reduce storm flows to a level that will be adequately conveyed by the mainline storm drain system, an allowable flow rate has been provided for each applicable property within the study area. The designated property owners shall mitigate their storm water discharges to not exceed their allowable mainline flow rates as provided herein, to prevent any significant adverse impacts to the downstream storm drain facilities in the study area. Any increase to the allowable flow rate may require additional planning area-specific analysis to ensure adequate flood control protection is provided.
VI. REFERENCES
1. Hydraulics Report for Mill Creek Storm Drain Delta 4 (M-1183), HZ Project No.
R310721.02 (July 2022)
2. TM 20529 & 20530, Colonial & Vander Eyk, Ontario, California, Preliminary Hydrology Report (July 2022)
3. TM 20449, Regions South, Ontario, California, Preliminary Hydrology Report (July 2022)
4. TTM 20526, Ontario, California, Preliminary Hydrology Report (March 2022)
5. PM19978, Ontario, California, Hydrology Report (March 2019)
6. Drainage Report for Onsite Improvement Plan, Tentative Tract Map No. 20081, City of Ontario, California (February 2019)
7. Drainage Report for New Haven in New Model Colony, Tract 20076, City of Ontario, California (November 2017)
8. Master Plan of Drainage, City of Ontario, Final Report (March 2012)
9. San Bernardino County, Hydrology Manual (1986)
6099
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc.
APPENDIX A
EXHIBITS AND HYDROLGY MAP
6100
NOT TO SCALE
PROPOSED RICH-HAVEN SPECIFIC PLAN
PLANNNING AREA AND PROPOSED LAND USE
2012 MASTER PLAN OF DRAINAGE
LAND USES
EXHIBIT 1
MPoD LAND USES VS. RICH-HAVEN
SPECIFIC PLAN LAND USES NOT TO SCALE
HAVEN AVE
Mixed Use
Mixed Use
Open Space - Non Recreation
Open Space - Parkland
Other
Residential
Low Density
Low - Medium Density
Medium Density
ADOPTED BY CITY COUNCIL
*
ON JANUARY 27, 2010
RICH-HAVEN SPECIFIC
PLAN AREA
(2.1-5DU/AC)
(5.1-11DU/AC)
(11.1-25DU/AC)
6101
X
72"
48"
36"
60" 84" 96" 96" 84"
48" 60"
48"
48"
48"
72"
60"
96"
10'x8' 108" 108"
54"
84"
60"
84"
72"
72"
54" 48" 36"
54"
36" 36"
48" 48"
SCALE 1" =1200'
CHINO AIRPORT
X"
X
MPoD RICH-HAVEN WATERSHED
(1,062.1 ACRES)
RICH-HAVEN PROJECT AREA
(584.2 ACRES) MARKED UP
EXHIBIT 2 6102
LEGEND
PROPOSED HYDROLOGY MAP
RICH-HAVEN SPECIFIC PLAN
HAVEN AVENUE STORM DRAIN
MILL CREEK AVENUE STORM DRAIN
EXHIBIT 3
2022-09-12
CHINO AVENUE
ONTARIO RANCH ROAD HAVEN AVENUE
MILL CREEK AVENUE TWINKLE AVENUE
RIVERSIDE DRIVE HAMNER AVENUE
6103
PROPOSED END CONSTRUCTION
ONTARIO RANCH
ROAD
ONTARIO RANCH
ROAD NOT A PART
PROPOSED IMPROVEMENT OLD EDISON AVENUE OLD EDISON AVENUE
NOT A PART IMPROVEMENT RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 SHEETS: 3-8, 10, 11, 18-20, & 22 6104
1 CONSTRUCT MANHOLE CONE TO PROPOSED GRADE
AND EXTEND MANHOLE BY RINGS TO THE EXISTING
GROUND. 10
STA. 00+09.52
25 EXISTING CONCRETE
ENCASEMENT 25 10 659.52 INV
11+11.55 9
ULTIMATE CATCH BASIN
LOCATION (LOCATED 10'
NORTH OF BCR TO CREATE
GREATER CONNECTION LENTH)
ULTIMATE DEPTH=15'
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
11+35.62 EC(659.62 INV.)
(659.62 INV.) 11+45.62
659.69 INV.
N1°51'00"E
11+37.82 11+35.62 EC 10+88.24 BC 667.37 INV.
667.37 INV. 660.58
KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6105
1 CONSTRUCT MANHOLE CONE TO PROPOSED GRADE
AND EXTEND MANHOLE BY RINGS TO THE EXISTING
GROUND. STA. 10
00+11.72
25 25 RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
660.58 JOIN APPROVED ALIGNMENT
STA. 13+82.97661.46 INV
KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6106
4 1
1 25 25
CONSTRUCT MANHOLE CONE TO PROPOSED GRADE
AND EXTEND MANHOLE BY RINGS TO THE EXISTING
GROUND. 10END
STA. 00+11.07 1
10 END STA.
00+17.15
10 END STA.
00+11.07
10 END
STA.
00+11.07
25 25 RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6107
3 25 25 25 25
CONSTRUCT MANHOLE CONE TO PROPOSED GRADE
AND EXTEND MANHOLE BY RINGS TO THE EXISTING
GROUND. 25 10 END
STA. 00+14.73
END 10
STA. 00+11.72
END 10
STA. 00+11.72
20 3 3
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
36+55.35
683.55 INV
36+65.68
683.62 INV
36+79.30
683.71 INV
36+84.80
683.75 INV
SEE LATERAL
ON SHEET 14
35+93.87
700.63 RIM
36+62.60
701.83 RIM
LATERAL A1-3
LATERAL
A1-5
LATERAL
A1-6
36+82.05 CL INT.
1+00 LAT HAVEN-A1-6
SEE LATERAL ON SHEET 20
12 G 36+59.10 CL INT. 1+00.00 LAT A1-5
SEE LATERAL ONSHEET 20
CONSTRUCT 4.00 LF OF
36" RCP D LOAD=2250 1+11.79 685.22 INV
PROP FINISHED SURFACE
@ CL PIPE
EXIST GROUND
HAVEN
90" RCP
INV=682.32 1+15.79 685.26 INV
LATERAL A1-3 STA. 1+15.79 690 700 10 G
18°59'43" 22.61' 7.49' 3.78' KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6108
1 1
4 25 25
CONSTRUCT MANHOLE CONE TO PROPOSED GRADE
AND EXTEND MANHOLE BY RINGS TO THE EXISTING
GROUND. 25 END
STA. 00+11.72
10 END STA.
00+11.07
10 END STA.
00+15.79
10 RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6109
STA. 68+45.03 CL INT
0+00.00 LAT HAVEN N1
14 62+15.60 CL INT.
1+00 LAT HAVEN-A8
14 MH NO. 14
62+19.13
717.03 RIM
LAT HAVEN-A8
42" RCP
703.12 INV
62+13.65
701.37 INV
62+125.65
701.45 INV
113.65 LF 61.08 LF 68+43.13 705.25 INV 68+53.13 705.31 INV LAT N1
36" RCP
707.98 INV
CONSTRUCT 295.67 LF OF 84" RCP
D LOAD=2100
CONSTRUCT 115.85 LF
OF 84" RCP
D LOAD=2100
STA. 69+15.25 CL INT
0+00.00 LAT HAVEN N2
0+00.00 LAT HAVEN N4
14 69+13.64
705.69 INV 69+23.64 705.75 INV
LAT N2 &N4
18" RCP
708.44 INV
CONSTRUCT 60.51 LF OF 84" RCP
D LOAD=2100
25 25 25 25
CONSTRUCT MANHOLE CONE TO PROPOSED GRADE
AND EXTEND MANHOLE BY RINGS TO THE EXISTING
GROUND.
25 10
STA. 00+95.87
10 STA. 01+61.19
MH NO. N1
68+50.10
720.06 RIM
MH NO. N2
69+20.56
720.58 RIM
PROPOSED LAT N1
3 86.07 LF
49.40 LF
4 ONTARIO RANCH ROAD
2410
STA. 01+61.19 49.40 LF 64+21.63 CL INT. 1+00 LAT HAVEN-N3 14 LAT N3
30" RCP
704.94 INV
64+19.72
702.63 INV 64+31.72
702.70 INV
25 MH NO. N3
64+28.44
718.00 RIM
CONSTRUCT 127.49 LF
OF 84" RCP
D LOAD=2100
CONSTRUCT 115.74 LF
OF 84" RCP
D LOAD=2100 24
CONSTRUCT 30" RCP (D-LOAD PER PROFILE).
N1 STA. 0+39.29 EC STA. 0+15.73 BC
CL CB #N4
ST STA 158+92.30
W=7', V=6.2', H=4" 15
CL CB #N2
ST STA 159+15.63
W=7', V=8.3', H=4"
15 LAT HAVEN N4
SEE SHEET 15
L=42.73 LF
N89°40'13"E 1
PROPOSED LAT N2
21.40 LF
1 70+39.49
706.46 INV
MH NO. 16
70+46.40
720.24 RIM
70+49.49
706.52 INV
50.51 LF
LAT N5
36" RCP
709.19 INV
STA. 01+55.50 3
STA. 0+15.74 BC 44.74 LF STA. 1+33.45 EC N5
STA. 70+41.10 CL INT
1+00.00 LAT HAVEN N5
14 STA. 0+20.92 BC
N2 3
CONSTRUCT 36" RCP (D-LOAD PER PROFILE). RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF. STA. 1+17.89 BC STA. 1+53.28 EC STA. 1+15.20 BC
STA. 1+32.87 EC
CMP INLET
(710.65 INV.)
CMP INLET(708.00 INV.)
CMP INLET(710.87 INV.)
A1-34 A1-35
LAT HAVEN-A1-35
30" RCP
704.06 INV N3 A8 N1
N2 N3 45°03'50" 45.00' 35.39' 18.67' 27°35'32" 22.50' 10.84' 5.52' 44°59'45" 30.00' 23.56' 12.43' N5
45°07'03" 22.50' 17.72' 9.35' A8 45°59'37" 22.50' 17.67' 9.32' KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6110
STA. 75+05.76
REMOVE BRICK
& MORTAR PLUG
BEGIN CONSTRUCTION
ONTARIO RANCH ROAD ONTARIO RANCH ROAD
CONSTRUCT
405.76 LF OF 84" RCP
D LOAD=2100
INSTALL 4' OF 18" RCP AT END OF CATCH BASIN
CONSTRUCT BRICK & MORTAR PLUG END CONSTRUCTION
715.35 INV
1 10
ONTARIO RANCH ROAD
120' ± S/O
ONTARIO RANCH ROAD STA 75+05.76
RECORD DRAWINGS
THESE RECORD DRAWINGS HAVE BEEN PREPARED IN
PART ON THE BASIS OF INFORMATION COMPILED AND
FURNISHED BY OTHERS. THE ENGINEER WILL NOT BE
RESPONSIBLE FOR ANY ERRORS OR OMISSIONS
WHICH HAVE BEEN INCORPORATED INTO THESE
DOCUMENTS AS A RESULT THEREOF.
STA. 74+05.76
REMOVE BRICK
& MORTAR PLUG
& JOIN EXISTING 84"
NOT A PART
EXISTING
IMPROVEMENT
PROPOSED
IMPROVEMENT
NOT A PART
EXISTING
IMPROVEMENT
PROPOSED
IMPROVEMENT
EXISTING GROUND
STA 74+05.76
KHOI DO, P.E./ CITY ENGINEER BRYAN LIRLEY, P.E./ PRINCIPAL ENGINEER RECOMMENDED BY: ACCEPTED BY: DATE DATE 1 11/4/19 HZ RCE CA 46049 6111
SCALE:
HOR. 1":40'
VERT1": 4'
MILL CREEK STORM DRAIN PLAN
SHEET 1 OF 4- BELLEGRAVE AVENUE TO NORTH OF MERRILL AVENUE
BELLGRAVE
AVENUE
MERRILL
AVENUE
6117
SCALE:
HOR. 1":40'
VERT1": 4'
MILL CREEK STORM DRAIN PLAN
SHEET 2 OF 4- NORTH OF MERRILL AVENUE TO NORTH OF OLD EDISON AVENUE OLD
EDISON
AVENUE
6118
SCALE:
HOR. 1":40'
VERT1": 4'
MILL CREEK STORM DRAIN PLAN
SHEET 3 OF 4- NORTH OF OLD EDISON AVENUE TO MID OF MIRALOMA SUBSTATION
MIRALOMA
SUBSTATION
ACCESS ROAD
ONTARIO
RANCH ROAD
6119
SCALE:
HOR. 1":40'
VERT1": 4'
MILL CREEK STORM DRAIN PLAN
SHEET 4 OF 4- MID OF MIRALOMA SUBSTATION TO CHINO AVENUE CHINO
AVENUE
6120
Rich-Haven Specific Plan Hydrology Report Ontario, CA
September, 2022
X Engineering & Consulting, Inc. 2
APPENDIX B
HYDROLGY CALCULATIONS
6121
San Bernardino County Rational Hydrology Program
(Hydrology Manual Date - August 1986)
CIVILCADD/CIVILDESIGN Engineering Software, (c) 1989-2018 Version 9.0 Rational Hydrology Study Date: 09/08/22
------------------------------------------------------------------------ Rich-Haven Specific Plan
Hydrology Study
100-yr Storm
Haven Storm Drain
------------------------------------------------------------------------ Program License Serial Number 6440
------------------------------------------------------------------------ ********* Hydrology Study Control Information ********** ------------------------------------------------------------------------ Rational hydrology study storm event year is 100.0
Computed rainfall intensity:
Storm year = 100.00 1 hour rainfall = 1.200 (In.)
Slope used for rainfall intensity curve b = 0.6000
Soil antecedent moisture condition (AMC) = 2
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4070.000 to Point/Station 4070.000 **** USER DEFINED FLOW INFORMATION AT A POINT ****
______________________________________________________________________ Soil classification AP and SCS values input by user
USER INPUT of soil data for subarea
SCS curve number for soil(AMC 2) = 32.46
Pervious ratio(Ap) = 0.3620 Max loss rate(Fm)= 0.353(In/Hr) Rainfall intensity = 2.348(In/Hr) for a 100.0 year storm User specified values are as follows:
TC = 19.60 min. Rain intensity = 2.35(In/Hr)
Total area this stream = 67.70(Ac.)
Total Study Area (Main Stream No. 1) = 67.70(Ac.)
Total runoff = 121.60(CFS)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4070.000 to Point/Station 4075.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 744.000(Ft.)
Downstream point/station elevation = 740.000(Ft.)
Pipe length = 660.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 121.600(CFS)
Given pipe size = 54.00(In.)
Calculated individual pipe flow = 121.600(CFS)
Normal flow depth in pipe = 36.33(In.)
6122
Flow top width inside pipe = 50.67(In.)
Critical Depth = 38.94(In.)
Pipe flow velocity = 10.68(Ft/s)
Travel time through pipe = 1.03 min.
Time of concentration (TC) = 20.63 min.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4070.000 to Point/Station 4075.000 **** CONFLUENCE OF MAIN STREAMS ****
______________________________________________________________________ The following data inside Main Stream is listed:
In Main Stream number: 1
Stream flow area = 67.700(Ac.)
Runoff from this stream = 121.600(CFS)
Time of concentration = 20.63 min.
Rainfall intensity = 2.277(In/Hr)
Area averaged loss rate (Fm) = 0.3530(In/Hr)
Area averaged Pervious ratio (Ap) = 0.3620
Program is now starting with Main Stream No. 2
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 401.000 to Point/Station 402.000 **** INITIAL AREA EVALUATION ****
______________________________________________________________________ PARK subarea
Decimal fraction soil group A = 1.000
Decimal fraction soil group B = 0.000
Decimal fraction soil group C = 0.000
Decimal fraction soil group D = 0.000
SCS curve number for soil(AMC 2) = 32.00
Pervious ratio(Ap) = 0.8500 Max loss rate(Fm)= 0.831(In/Hr) Initial subarea data:
Initial area flow distance = 640.000(Ft.)
Top (of initial area) elevation = 765.000(Ft.)
Bottom (of initial area) elevation = 761.000(Ft.)
Difference in elevation = 4.000(Ft.)
Slope = 0.00625 s(%)= 0.63
TC = k(0.483)*[(length^3)/(elevation change)]^0.2
Initial area time of concentration = 17.670 min.
Rainfall intensity = 2.499(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.601 Subarea runoff = 7.264(CFS)
Total initial stream area = 4.840(Ac.)
Pervious area fraction = 0.850
Initial area Fm value = 0.831(In/Hr)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 402.000 to Point/Station 403.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 753.000(Ft.)
Downstream point/station elevation = 747.000(Ft.)
6123
Pipe length = 760.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 7.264(CFS)
Given pipe size = 36.00(In.)
Calculated individual pipe flow = 7.264(CFS)
Normal flow depth in pipe = 8.51(In.)
Flow top width inside pipe = 30.59(In.)
Critical Depth = 10.15(In.)
Pipe flow velocity = 5.69(Ft/s)
Travel time through pipe = 2.23 min.
Time of concentration (TC) = 19.90 min.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 402.000 to Point/Station 403.000 **** SUBAREA FLOW ADDITION ****
______________________________________________________________________ PARK subarea
Decimal fraction soil group A = 1.000
Decimal fraction soil group B = 0.000
Decimal fraction soil group C = 0.000
Decimal fraction soil group D = 0.000
SCS curve number for soil(AMC 2) = 32.00
Pervious ratio(Ap) = 0.8500 Max loss rate(Fm)= 0.831(In/Hr) Time of concentration = 19.90 min.
Rainfall intensity = 2.327(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.579
Subarea runoff = 14.841(CFS) for 11.580(Ac.)
Total runoff = 22.106(CFS)
Effective area this stream = 16.42(Ac.)
Total Study Area (Main Stream No. 2) = 84.12(Ac.)
Area averaged Fm value = 0.831(In/Hr)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 403.000 to Point/Station 4075.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 747.000(Ft.)
Downstream point/station elevation = 740.000(Ft.)
Pipe length = 20.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 22.106(CFS)
Given pipe size = 36.00(In.)
Calculated individual pipe flow = 22.106(CFS)
Normal flow depth in pipe = 5.78(In.)
Flow top width inside pipe = 26.44(In.)
Critical Depth = 18.14(In.)
Pipe flow velocity = 30.09(Ft/s)
Travel time through pipe = 0.01 min.
Time of concentration (TC) = 19.91 min.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 403.000 to Point/Station 4075.000 **** SUBAREA FLOW ADDITION ****
6124
______________________________________________________________________ COMMERCIAL subarea type
Decimal fraction soil group A = 1.000
Decimal fraction soil group B = 0.000
Decimal fraction soil group C = 0.000
Decimal fraction soil group D = 0.000
SCS curve number for soil(AMC 2) = 32.00
Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Time of concentration = 19.91 min.
Rainfall intensity = 2.326(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.619
Subarea runoff = 5.444(CFS) for 2.720(Ac.)
Total runoff = 27.549(CFS)
Effective area this stream = 19.14(Ac.)
Total Study Area (Main Stream No. 2) = 86.84(Ac.)
Area averaged Fm value = 0.727(In/Hr)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 401.000 to Point/Station 4075.000 **** CONFLUENCE OF MAIN STREAMS ****
______________________________________________________________________ The following data inside Main Stream is listed:
In Main Stream number: 2
Stream flow area = 19.140(Ac.)
Runoff from this stream = 27.549(CFS)
Time of concentration = 19.91 min.
Rainfall intensity = 2.326(In/Hr)
Area averaged loss rate (Fm) = 0.7269(In/Hr)
Area averaged Pervious ratio (Ap) = 0.7434
Summary of stream data:
Stream Flow rate Area TC Fm Rainfall Intensity
No. (CFS) (Ac.) (min) (In/Hr) (In/Hr)
1 121.60 67.700 20.63 0.353 2.277
2 27.55 19.140 19.91 0.727 2.326
Qmax(1) =
1.000 * 1.000 * 121.600) +
0.969 * 1.000 * 27.549) + = 148.302
Qmax(2) =
1.026 * 0.965 * 121.600) +
1.000 * 1.000 * 27.549) + = 147.895
Total of 2 main streams to confluence:
Flow rates before confluence point:
122.600 28.549
Maximum flow rates at confluence using above data:
148.302 147.895
Area of streams before confluence:
67.700 19.140
Effective area values after confluence:
86.840 84.472
6125
Results of confluence:
Total flow rate = 148.302(CFS)
Time of concentration = 20.630 min.
Effective stream area after confluence = 86.840(Ac.)
Study area average Pervious fraction(Ap) = 0.446
Study area average soil loss rate(Fm) = 0.435(In/Hr)
Study area total = 86.84(Ac.)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4075.000 to Point/Station 4120.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 740.000(Ft.)
Downstream point/station elevation = 729.300(Ft.)
Pipe length = 990.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 148.302(CFS)
Given pipe size = 60.00(In.)
Calculated individual pipe flow = 148.302(CFS)
Normal flow depth in pipe = 31.69(In.)
Flow top width inside pipe = 59.91(In.)
Critical Depth = 41.86(In.)
Pipe flow velocity = 14.11(Ft/s)
Travel time through pipe = 1.17 min.
Time of concentration (TC) = 21.80 min.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4120.000 to Point/Station 4120.000 **** CONFLUENCE OF MINOR STREAMS ****
______________________________________________________________________ Along Main Stream number: 1 in normal stream number 1
Stream flow area = 86.840(Ac.)
Runoff from this stream = 148.302(CFS)
Time of concentration = 21.80 min.
Rainfall intensity = 2.203(In/Hr)
Area averaged loss rate (Fm) = 0.4354(In/Hr)
Area averaged Pervious ratio (Ap) = 0.4461
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4075.000 to Point/Station 4120.000 **** INITIAL AREA EVALUATION ****
______________________________________________________________________ COMMERCIAL subarea type
Decimal fraction soil group A = 1.000
Decimal fraction soil group B = 0.000
Decimal fraction soil group C = 0.000
Decimal fraction soil group D = 0.000
SCS curve number for soil(AMC 2) = 32.00
Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Initial subarea data:
Initial area flow distance = 990.000(Ft.)
6126
Top (of initial area) elevation = 740.000(Ft.)
Bottom (of initial area) elevation = 729.300(Ft.)
Difference in elevation = 10.700(Ft.)
Slope = 0.01081 s(%)= 1.08
TC = k(0.304)*[(length^3)/(elevation change)]^0.2
Initial area time of concentration = 11.868 min.
Rainfall intensity = 3.173(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.872 Subarea runoff = 8.745(CFS)
Total initial stream area = 3.160(Ac.)
Pervious area fraction = 0.100
Initial area Fm value = 0.098(In/Hr)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4120.000 to Point/Station 4120.000 **** CONFLUENCE OF MINOR STREAMS ****
______________________________________________________________________ Along Main Stream number: 1 in normal stream number 2
Stream flow area = 3.160(Ac.)
Runoff from this stream = 8.745(CFS)
Time of concentration = 11.87 min.
Rainfall intensity = 3.173(In/Hr)
Area averaged loss rate (Fm) = 0.0978(In/Hr)
Area averaged Pervious ratio (Ap) = 0.1000
Summary of stream data:
Stream Flow rate Area TC Fm Rainfall Intensity
No. (CFS) (Ac.) (min) (In/Hr) (In/Hr)
1 148.30 86.840 21.80 0.435 2.203
2 8.75 3.160 11.87 0.098 3.173
Qmax(1) =
1.000 * 1.000 * 148.302) +
0.685 * 1.000 * 8.745) + = 154.290
Qmax(2) =
1.549 * 0.544 * 148.302) +
1.000 * 1.000 * 8.745) + = 133.786
Total of 2 streams to confluence:
Flow rates before confluence point:
148.302 8.745
Maximum flow rates at confluence using above data:
154.290 133.786
Area of streams before confluence:
86.840 3.160
Effective area values after confluence:
90.000 50.436
Results of confluence:
Total flow rate = 154.290(CFS)
Time of concentration = 21.800 min.
Effective stream area after confluence = 90.000(Ac.)
Study area average Pervious fraction(Ap) = 0.434
Study area average soil loss rate(Fm) = 0.424(In/Hr)
6127
Study area total (this main stream) = 90.00(Ac.)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4075.000 to Point/Station 4120.000 **** CONFLUENCE OF MAIN STREAMS ****
______________________________________________________________________ The following data inside Main Stream is listed:
In Main Stream number: 1
Stream flow area = 90.000(Ac.)
Runoff from this stream = 154.290(CFS)
Time of concentration = 21.80 min.
Rainfall intensity = 2.203(In/Hr)
Area averaged loss rate (Fm) = 0.4236(In/Hr)
Area averaged Pervious ratio (Ap) = 0.4339
Program is now starting with Main Stream No. 2
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4080.000 to Point/Station 4080.000 **** USER DEFINED FLOW INFORMATION AT A POINT ****
______________________________________________________________________ Soil classification AP and SCS values input by user
USER INPUT of soil data for subarea
SCS curve number for soil(AMC 2) = 32.04
Pervious ratio(Ap) = 0.3570 Max loss rate(Fm)= 0.349(In/Hr) Rainfall intensity = 2.612(In/Hr) for a 100.0 year storm User specified values are as follows:
TC = 16.41 min. Rain intensity = 2.61(In/Hr)
Total area this stream = 68.90(Ac.)
Total Study Area (Main Stream No. 2) = 158.90(Ac.)
Total runoff = 121.80(CFS)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4080.000 to Point/Station 410.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 747.700(Ft.)
Downstream point/station elevation = 745.890(Ft.)
Pipe length = 360.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 121.800(CFS)
Given pipe size = 60.00(In.)
Calculated individual pipe flow = 121.800(CFS)
Normal flow depth in pipe = 35.58(In.)
Flow top width inside pipe = 58.95(In.)
Critical Depth = 37.83(In.)
Pipe flow velocity = 10.05(Ft/s)
Travel time through pipe = 0.60 min.
Time of concentration (TC) = 17.01 min.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 4080.000 to Point/Station 410.000 **** CONFLUENCE OF MINOR STREAMS ****
6128
______________________________________________________________________ Along Main Stream number: 2 in normal stream number 1
Stream flow area = 68.900(Ac.)
Runoff from this stream = 121.800(CFS)
Time of concentration = 17.01 min.
Rainfall intensity = 2.557(In/Hr)
Area averaged loss rate (Fm) = 0.3490(In/Hr)
Area averaged Pervious ratio (Ap) = 0.3570
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 406.000 to Point/Station 407.000 **** INITIAL AREA EVALUATION ****
______________________________________________________________________ PARK subarea
Decimal fraction soil group A = 1.000
Decimal fraction soil group B = 0.000
Decimal fraction soil group C = 0.000
Decimal fraction soil group D = 0.000
SCS curve number for soil(AMC 2) = 32.00
Pervious ratio(Ap) = 0.8500 Max loss rate(Fm)= 0.831(In/Hr) Initial subarea data:
Initial area flow distance = 400.000(Ft.)
Top (of initial area) elevation = 765.000(Ft.)
Bottom (of initial area) elevation = 762.000(Ft.)
Difference in elevation = 3.000(Ft.)
Slope = 0.00750 s(%)= 0.75
TC = k(0.483)*[(length^3)/(elevation change)]^0.2
Initial area time of concentration = 14.118 min.
Rainfall intensity = 2.859(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.638 Subarea runoff = 4.344(CFS)
Total initial stream area = 2.380(Ac.)
Pervious area fraction = 0.850
Initial area Fm value = 0.831(In/Hr)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 407.000 to Point/Station 410.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 749.000(Ft.)
Downstream point/station elevation = 745.890(Ft.)
Pipe length = 100.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 4.344(CFS)
Given pipe size = 24.00(In.)
Calculated individual pipe flow = 4.344(CFS)
Normal flow depth in pipe = 5.35(In.)
Flow top width inside pipe = 19.98(In.)
Critical Depth = 8.77(In.)
Pipe flow velocity = 8.33(Ft/s)
Travel time through pipe = 0.20 min.
Time of concentration (TC) = 14.32 min.
6129
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 407.000 to Point/Station 410.000 **** SUBAREA FLOW ADDITION ****
______________________________________________________________________ COMMERCIAL subarea type
Decimal fraction soil group A = 1.000
Decimal fraction soil group B = 0.000
Decimal fraction soil group C = 0.000
Decimal fraction soil group D = 0.000
SCS curve number for soil(AMC 2) = 32.00
Pervious ratio(Ap) = 0.1000 Max loss rate(Fm)= 0.098(In/Hr) Time of concentration = 14.32 min.
Rainfall intensity = 2.835(In/Hr) for a 100.0 year storm Effective runoff coefficient used for area,(total area with modified rational method)(Q=KCIA) is C = 0.676
Subarea runoff = 1.156(CFS) for 0.490(Ac.)
Total runoff = 5.499(CFS)
Effective area this stream = 2.87(Ac.)
Total Study Area (Main Stream No. 2) = 161.77(Ac.)
Area averaged Fm value = 0.706(In/Hr)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 406.000 to Point/Station 410.000 **** CONFLUENCE OF MINOR STREAMS ****
______________________________________________________________________ Along Main Stream number: 2 in normal stream number 2
Stream flow area = 2.870(Ac.)
Runoff from this stream = 5.499(CFS)
Time of concentration = 14.32 min.
Rainfall intensity = 2.835(In/Hr)
Area averaged loss rate (Fm) = 0.7059(In/Hr)
Area averaged Pervious ratio (Ap) = 0.7220
Summary of stream data:
Stream Flow rate Area TC Fm Rainfall Intensity
No. (CFS) (Ac.) (min) (In/Hr) (In/Hr)
1 121.80 68.900 17.01 0.349 2.557
2 5.50 2.870 14.32 0.706 2.835
Qmax(1) =
1.000 * 1.000 * 121.800) +
0.869 * 1.000 * 5.499) + = 126.581
Qmax(2) =
1.126 * 0.842 * 121.800) +
1.000 * 1.000 * 5.499) + = 120.958
Total of 2 streams to confluence:
Flow rates before confluence point:
121.800 5.499
Maximum flow rates at confluence using above data:
126.581 120.958
Area of streams before confluence:
68.900 2.870
6130
Effective area values after confluence:
71.770 60.874
Results of confluence:
Total flow rate = 126.581(CFS)
Time of concentration = 17.007 min.
Effective stream area after confluence = 71.770(Ac.)
Study area average Pervious fraction(Ap) = 0.372
Study area average soil loss rate(Fm) = 0.363(In/Hr)
Study area total (this main stream) = 71.77(Ac.)
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Process from Point/Station 410.000 to Point/Station 415.000 **** PIPEFLOW TRAVEL TIME (User specified size) ****
______________________________________________________________________ Upstream point/station elevation = 745.890(Ft.)
Downstream point/station elevation = 741.230(Ft.)
Pipe length = 930.00(Ft.) Manning's N = 0.013
No. of pipes = 1 Required pipe flow = 126.581(CFS)
Given pipe size = 60.00(In.)
Calculated individual pipe flow = 126.581(CFS)
Normal flow depth in pipe = 36.52(In.)
Flow top width inside pipe = 58.57(In.)
Critical Depth = 38.63(In.)
Pipe flow velocity = 10.12(Ft/s)
Travel time through pipe = 1.53 min.