REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
3P
MCP
FVNR
SLUDGE
65 KAIC
SIZE 1
15 AC

SECONDARY
PUMP NO. 1
5 3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 1
3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 2
3P
MCP
FVNR
3/4
65 KAIC
SIZE 1
3 AC

HOT WATER
PUMP
HWCP-5
3P
MCP
FVNR

1.5 65 KAIC
SIZE 1
7 AC

RAPID MIX
PUMP
5 3P
MCP

7.5 3
-#12
(Ø
)
& 1-#12
(G
)
15 AC 65 KAIC

RAPID MIX
PUMP
PMP-85104
3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 3
3P
MCP
50 RVSS
100 AC 65 KAIC
BLOWER NO. 1
3P
MCP
50 RVSS
100 AC 65 KAIC
BLOWER NO. 2
3P
MCP
60 FILTER
65 KAIC
SIZE 4
100 AC
PUMP NO. 1

BACKWASH
3P
TM
15 AT 65 KAIC

UNIT HEATER
UH-9
KW
3 3P
TM
15 AT 65 KAIC

ROLL UP DOOR
HP
2 3P
MCP
60 FILTER
65 KAIC
SIZE 4
100 AC
PUMP NO. 2

BACKWASH
3P
MCP
FVNR
65 KAIC
SIZE 2
15 AC
AIR

COMPRESSOR
5 3P
MCP
FVNR
65 KAIC
SIZE 2
30 AC
3P
TM
30 KVA

50 AT 65 KAIC
XFMR-A
208/120 V
480 V

LIGHTING

PANELBOARD
PNL-A
3 PH
TM
3P
60 AT 65 KAIC
DP1

DISTRIBUTION
PANEL 1
3P
MCP
FVNR
15 FILTER
65 KAIC
SIZE 2
30 AC
PUMP

SURFACE WASH
3P
MCP
FVNR
65 KAIC
SIZE 2
30 AC
3P
TM
300 AT 65 KAIC
400 AF
MCC-C, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS CON
TINU
ED
AT
UPPER
R
IGH
T
CON
TINU
ED
AT
LO
W

ER LEFT
# KEY NOTES:
1 1 1
REMAIN IN PLACE.

UNDERGROUND AND CONCRETE EMBEDDED CONDUITS SHALL
WHICH ARE MARKED ON THIS DRAWING FOR DEMOLITION.

1. DEMOLISH EXPOSED CONDUITS, AND ALL CABLES FOR CIRCUITS 3P
TM
400 AT 65 KAIC
400 AF
SPD
MAIN BREAKER 1 MAIN BREAKER 2
3P K K
TM
65 KAIC
DP2

DISTRIBUTION
PANEL 2
CON
TINU
ED ON
N
EXT
S
HEET
06N05
6 06N06
6 06N06
6 06N06

SPARE SPARE

AIR WASH AIR WASH
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 1

AIR WASH
50 AC
BLO-85106
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 3

AIR WASH
50 AC
BLO-85108
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 2

AIR WASH
50 AC
BLO-85107
100 AT
3 -#2
(Ø
)
& 1-#8
(G
)
P
lotD
ate: 05
-APR
-2023 1:11:46
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E11
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E11.dgn

MCC-C MODIFIED
ONE-LINE DIAGRAM 1
JGB
103
bshepard
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:33:45-07'00'
200

Page 342 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®

CONTINUED ON PREVIOUS SHEET
3P
MCP
1/2
3-#12(Ø)& 1-#12(G)
3 AC 65 KAIC
FAN-85109
FVNR
SIZE 1
FAN NO. 1
3P
MCP
1/2
3-#12(Ø)& 1-#12(G)
3 AC 65 KAIC
FAN-85110
FVNR
SIZE 1
FAN NO. 2
3P
MCP
1/2
3-#12(Ø)& 1-#12(G)
3 AC 65 KAIC
FAN-85111
FVNR
SIZE 1
FAN NO. 3
MCC-C, 600 AMPS, 480 V, 3 Ø, 3 WIRE, 60HZ, 65KASC RMS

AIR WASH BLOWER AIR WASH BLOWER AIR WASH BLOWER
3P
MCP
1/2
3-#10(Ø)& 1-#12(G)
3 AC 65 KAIC
PMP-87134
FVNR
SIZE 1

BACKWASH

CHLORINE SAMPLE PUMP
PlotDate: 05-APR-2023 1:12:34PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 03E12
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
SMB

ELECTRICAL
8660F10 8660F1003E12.dgn

MCC-C MODIFIED
ONE-LINE DIAGRAM 2
JGB
104
ggraham
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:30:42-07'00'
200

Page 343 of 1800 ends

20"
90"
20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
5 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
#
GENERAL NOTES:

KEY NOTES:

1. EXISTING MCC IS SQUARE D MODEL 6.

2. PROVIDE NEW COVER.

SCHEMATICS, AND SPECIFICATIONS.

EQUIPMENT ACCORDING TO ONE-LINE DIAGRAMS, CONTROL

1. PROVIDE NEW BREAKER, DRIVES AND ALL THE NECESSARY
3/4" = 1'-0"
8660F1003E0622
3/4" = 1'-0"
8660F1003E0622
5A- SPACE
5C- GDR75112
SLUDGE

GRINDER
DIGESTER 1
5D- P97101

DRAINAGE
PUMP 1
5E- PMP-89100

CAROUSEL
PUMP NO. 1
5F- FV-60100
DCL

STRUCTURE
VALVE 1
5G- FV-60102
DCL

STRUCTURE
VALVE 2
5H- SPACE
5J- SPACE
P
lotD
ate: 05
-APR
-2023 1:11:38
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E18
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1003E18.dgn
MCC70291 PARTIAL ELEVATION
2 1
JGB
2 ggraham
105
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:03-07'00'
200

Page 344 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
CON
TINU
ED
AT
LO
W

ER LEFT
CON
TINU
ED
AT
UPPER
R
IGH
T
3P
TM
10 20 AT 65 KAIC

DAFT AIR
COMPRESSOR 1
LCP70201
HP
3P
MCP
FVNR
1/2
SAMPLE
PUMP 1
65 KAIC
SIZE 1
3 AC

CHLORINE

RESIDUAL
P60211
3P
MCP
FVNR
40 PUMP 1
65 KAIC
SIZE 3
100 AC

PRESSURIZATION
P70221
3P
MCP
FVNR
65 KAIC
SIZE 1
15 AC
DIGESTER 1
PUMP

CIRCULATION
P75111
5 3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC

RECLAIMED
FEED PUMP 1

WATER FILTER
P80111
3P
TM
UNIT 1

POLYMER
20 AT 65 KAIC

BLENDING
PNL70251
AMP
1 3P
TM

GRINDER
SLUDGE
15 AT 65 KAIC
DIGESTER 1
GDR75112
HP
3 SPD
3 MCC70291, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS SSM
3 SSM
SWB70281
MLO
SWB70282
MLO
3P
TM
FVNR

1.5 SLUDGE
DAFT 1
15 AT 65 KAIC
SIZE 1
COL70121B

COLLECTOR
3P
MCP

7.5 15 AT 65 KAIC
MX75101
DIGESTER 1
MIXER

7.5 3P
TM
VFD
20 AT 65 KAIC
P70131

THICKENED
SLUDGE
PUMP 1
VFD70131
3P
TM
35 AT 65 KAIC
HP
20 P97101

DRAINAGE
PUMP 1
3 PHASE
15 KVA
TM
3P

480V
208/120V
45 AT 65 KAIC
XFMR70271 PNL70271
SPARE
SIZE 1
FVNR
MCP
3P
15 AT 65 KAIC
SPARE
TM
3P
20 AT 65 KAIC
LL
40 3P
TM
80 AT 65 KAIC

CAROUSEL
VFD-89100
PMP-89100
PUMP NO. 1
VFD-6
VFD
DV/DT
3P
TM
VALVE 2
3 -#10
(Ø
)
& 1-#10
(G
)
3 -#10
(Ø
)
& 1-#10
(G
)
15 AT 65 KAIC
5 HP
FV-60102

DCL STRUCTURE
3P
TM
VALVE 1
3 -#10
(Ø
)
& 1-#10
(G
)
3 -#10
(Ø
)
& 1-#10
(G
)
15 AT 65 KAIC
5 HP
FV-60100

DCL STRUCTURE
VFD-6
3/4
3P
15 AT 65 KAIC
TM
COL70121A
DAFT 1 FLOAT

COLLECTOR
3 -#6
(Ø
)
& 1-#8
(G
)
[3
-#4
(Ø
)
&
INTEG
R
AL
(G)]:VFD

1. EXISTING MCC IS SQUARE D MODEL 6.
#
H040S2BLG.

CORPORATION, MODEL# BF48A, AND CATALOG#:

AND 16262. EXISTING MOTOR IS MADE BY NIDEC MOTOR
MANUFACTURER, AND SPECIFICATION SECTIONS 16222

SHALL BE COORDINATED WITH THE EXISTING PUMP
WITH NEW VFD DUTY RATED MOTOR. MOTOR SELECTION

1. REPLACE EXISTING MOTOR FOR THE EXISTING PUMP
GENERAL NOTES:

KEY NOTES:
1 P
lotD
ate: 05
-APR
-2023 1:10:49
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E19
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
MCC70291 ONE-LINE DIAGRAM
8660F10 8660F1003E19.dgn
3 06N03
JGB
avates
106
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:37:54-07'00'
200

Page 345 of 1800 ends

20"
90"
20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
6 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
#
GENERAL NOTES:

KEY NOTES:

1. EXISTING MCC IS SQUARE D MODEL 6.
1 SPECIFICATIONS.

ACCORDING TO ONE-LINE DIAGRAMS, CONTROL SCHEMATICS, AND

1. PROVIDE NEW BREAKER AND ALL THE NECESSARY EQUIPMENT
6A- POLYMER
BLENDING UNIT 2
PNL70272
6B- 20A SPARE

BREAKER
6C- LCP70202
DAFT AIR COMP 2
6D- SPARE
STARTER - SIZE 1
6F- GDR75122
DIGESTER 2

SLUDGE GRINDER
6G- PMP-89101
CAROUSEL PUMP NO. 2
6H- SPACE
6J- SWB70282
3/4" = 1'-0"
8660F1003E0623
3/4" = 1'-0"
8660F1003E0623
P
lotD
ate: 05
-APR
-2023
3:23:29
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E20
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1003E20.dgn
MCC70292 PARTIAL ELEVATION
JGB
107
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:40:09-07'00'
200

Page 346 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
CON
TINU
ED
AT
LO
W

ER LEFT
CON
TINU
ED
AT
UPPER
R
IGH
T
MLO
MLO
3P
MCP
FVNR

1.5 SLUDGE
DAFT 2
65 KAIC
SIZE 1
7 AC

COLLECTOR
COL70122B
3P
TM
10 20 AT 65 KAIC

DAFT AIR
COMPRESSOR 2
LCP70202
HP
3P
MCP
FVNR
1/2
SODIUM
65 KAIC
SIZE 1
3 AC
UNIT

INDUCTION

HYPOCHLORITE
MME60202
3P
MCP
FVNR
1/2
SODIUM
65 KAIC
SIZE 1
3 AC
UNIT

INDUCTION

BISULFITE
MME60401
3P
TM
UNIT 2

POLYMER
15 AT 65 KAIC

BLENDING
MME70252
HP
1 3P
MCP
FVNR
1/2
SAMPLE
PUMP 2
65 KAIC
SIZE 1
3 AC

CHLORINE

RESIDUAL
P60213
3P
MCP
FVNR
40 PUMP 2
65 KAIC
SIZE 3
100 AC

PRESSURIZATION
P70222
3P
MCP
FVNR

7.5 65 KAIC
SIZE 1
15 AC
DIGESTER 2
PUMP

CIRCULATION
P75121
3P
TM
SLUDGE

GRINDER
15 AT 65 KAIC
DIGESTER 2
PNL75122
HP
3 SPD
SSM
3 SWB70281
SSM
3 SWB70282
MCC70292, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC

RECLAIMED
FEED PUMP 2

WATER FILTER
P80112
VFD-6
LL
40 3P
TM
65 KAIC

CAROUSEL
VFD-89101
80 AT
PMP-89101
3P
TM

7.5 20 AT 65 KAIC
MX75102
DIGESTER 2
MIXER

7.5 3P
TM
20 AT 65 KAIC

THICKENED
SLUDGE
PUMP 2
P70132
DV/DT
3 PHASE
15 KVA
TM
3P

480 V
120/2080 V
45 AT 65 KAIC
XFMR70272 PNL-70272
VFD
VFD
SPARE
TM
3P
20 AT 65 KAIC
SPARE
SIZE 1
FVNR
MCP
3P
15 AC 65 KAIC
[3
-#4
(Ø
)
&
INTEG
R
AL
(G)]:VFD
3 -#6
(Ø
)
& 1-#8
(G
)
HP
3P
TM
COL70122A
DAFT 2 FLOAT

COLLECTOR
VFD

1. EXISTING MCC IS SQUARE D MODEL 6.
#
H040S2BLG.

CORPORATION, MODEL# BF48A, AND CATALOG#:

AND 16262. EXISTING MOTOR IS MADE BY NIDEC MOTOR
MANUFACTURER, AND SPECIFICATION SECTIONS 16222

SHALL BE COORDINATED WITH THE EXISTING PUMP
WITH NEW VFD DUTY RATED MOTOR. MOTOR SELECTION

1. REPLACE EXISTING MOTOR FOR THE EXISTING PUMP
GENERAL NOTES:

KEY NOTES:
1 3
06N03
PUMP NO. 2

P
lotD
ate: 05
-APR
-2023 1:11:28
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E21
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
MCC70292 ONE-LINE DIAGRAM
8660F10 8660F1003E21.dgn
JGB
108
ggraham
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:34:59-07'00'
200

Page 347 of 1800 ends

20"
90"
20"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

FRONT VIEW SIDE VIEW
FILE:

SCALE:

FILE:

SCALE:
7 A -
B -
C -
D -
E -
F -
G -
H -
I -
J -
K -
L -
#
GENERAL NOTES:

KEY NOTES:

1. EXISTING MCC IS SQUARE D MODEL 6.

2. PROVIDE NEW COVER.

ACCORDING TO SINGLE LINE DIAGRAMS AND SPECIFICATIONS.

1. PROVIDE NEW BREAKER AND ALL THE NECESSARY EQUIPMENT
1 2
7A- SPACE
7B- 30A SPARE

BREAKER
7C- UH70244
DAFT EQUIP. ROOM

UNIT HEATER
7D- EDR-99101
EDR-99102

FLOW CONTROL
VALVES NO. 1 AND NO. 2
7E- PMP-89102
CAROUSEL PUMP NO. 3
7F- PMP-91100
PAU PUMP NO. 1
7G- SPACE
7I- METERING
7J- 600A MLO
3/4" = 1'-0"
8660F1003E0624
3/4" = 1'-0"
8660F1003E0624
P
lotD
ate: 05
-APR
-2023
3:20:02
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E22
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1003E22.dgn
MCC70293 PARTIAL ELEVATION
JGB
109
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:16-07'00'
200

Page 348 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
CON
TINU
ED
AT
LO
W

ER LEFT
CON
TINU
ED
AT
UPPER
R
IGH
T
MLO
MLO
SSM
3 SWB70281
SSM
3 SWB70282
3P
TM
10 20 AT 65 KAIC
DAFT
UNIT

HANDLING

BUILDING AIR
AHU70246
KW
3P
TM

1.5 DAFT 3
SLUDGE
FUTURE
15 AT 65 KAIC

COLLECTOR
HP
3P
TM
10 20 AT 65 KAIC

DAFT AIR
COMPRESSOR 3
LCP70203
HP
3P
MCP
FVNR
1/2
UNIT 1
SODIUM
65 KAIC
SIZE 1
3 AC

INDUCTION

HYPOCHLORITE
MME60201
3P
MCP
FVNR
1/2
SAMPLE
PUMP 4
65 KAIC
SIZE 1
3 AC

CHLORINE

RESIDUAL
P60411
3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC

RECLAIMED
FEED PUMP 3

WATER FILTER
P80113
3P
TM

POLYMER
UNIT 3
FUTURE
15 AT 65 KAIC

BLENDING
PLC70299
HP
1 SPD
TM
3P
65 KAIC
2 STORM DRAIN
PUMP 1
MCC70293, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3P
TM
3/4
FUTURE
15 AT 65 KAIC
DAFT 3 FLOAT

COLLECTOR
VCP-SD
2 STORM DRAIN
PUMP 2
3P
MCP
FVNR
20 BLOWER
50 AC 65 KAIC
SIZE 2

CHLORINATION

AERATION
B60221
3P
MCP
FVNR
1/2
SAMPLE
3 AC 65 KAIC
SIZE 1

RESIDUAL
P60215

CHLORINE
PUMP 3
PUMP

7.5 3P
TM
15 AT 65 KAIC

THICKENED
SLUDGE
VFD
P70133
3P
MCP
FVNR
40 65 KAIC
SIZE 3
P70223
100 AC

PRESSURIZATION
PUMP 3
3P
TM
20 PUMP 2
35 AT 65 KAIC
HP
P97102
3P
TM
15 AT 65 KAIC
KVA
5 PNL80114

RECLAIMED

WATER FILTER

CONTROL
PANEL
VFD-6
LL
10 3P
TM
25 AT 65 KAIC
3 -#10
(Ø
)
& 1-#10
(G
)
DV/DT
PMP-91100
VFD-91100
PAU PUMP NO. 1
VFD-6
LL
40 3P
TM
65 KAIC
DV/DT
PMP-89102
VFD-89102

CAROUSEL
3P
TM
20 AT 65 KAIC
RIVER

DISCHARGE

CONTROL VALVE
3 PHASE
15 KVA
TM
3P

480 V
120/208 V
45 AT 65 KAIC
XFMR70273 PNL70273
VFD

DRAINAGE
80 AT
TM
3P
HP HP
VALVE NO. 1

CONTROL
FLOW
EDR-99101
VALVE NO. 2

CONTROL
FLOW
EDR-99102
15 AT 65 KAIC
[3
-#8
(Ø
)
&
INTEG
R
AL
(G)]:VFD
[3
-#4
(Ø
)
&
INTEG
R
AL
(G)]:VFD
3 -#6
(Ø
)
& 1-#8
(G
)
3 -#10
(Ø
)
& 1-#10
(G
)

1. EXISTING MCC IS SQUARE D MODEL 6.

GENERAL NOTES:
4 06N04
3 06N04
PUMP NO. 3
P
lotD
ate: 05
-APR
-2023 1:11:18
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
03E23
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
MCC70293 ONE-LINE DIAGRAM
8660F10 8660F1003E23.dgn
bshepard
JGB
110
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:30-07'00'
200

Page 349 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
PANEL PNL-RWPS-L 3/6/2023
LIRWPS
LOCATION: RECYCLED WATER PUMP STATION ELECTRICAL BUILDING NEMA: 1 PH A WEIGHTED VA 6195 VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 4035
PHASE & WIRE: 3 PH 4W MTG. SURFACE PH C WEIGHTED VA 7613 INTERRUPT: 10 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 22838
MAIN RATING: 125 AF 100 AT PANEL AMPS 63.4

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C RECYCLED WATER ELECTRICAL BUILDING LIGHTING 280 20A-1P 1 A 2 20A-1P 720 RECYCLED WATER ELECTRICAL BUILDING RECEPTACLES I I RECYCLED WATER ELECTRICAL BUILDING RECEPTACLES 360 20A-1P 3 B 4 20A-1P 340 RECYCLED WATER PUMP STATION LIGHTING C I RECYCLED WATER PUMP STATION RECEPTACLES 900 20A-1P 5 C 6 35A-2P 2600 CU-99422 - OUTDOOR CONDENSER UNIT NO. 2 C C PCM-99400 POWER FEED NO. 1 1500 20A-1P 7 A 8 2600 FCU-99422 C S PCM-99400 POWER FEED NO. 2 1500 20A-1P 9 B 10 35A-2P 2600 CU-99421 - OUTDOOR CONDENSER UNIT NO. 1 C C RECYCLED WATER STORAGE LIGHTING 170 20A-1P 11 C 12 2600 FCU-99421 C SPARE 20A-1P 13 A 14 20A-1P SPARE
SPARE 20A-1P 15 B 16 20A-1P SPARE
SPARE 20A-1P 17 C 18 20A-1P SPARE
SPARE 20A-1P 19 A 20 20A-1P SPARE
SPARE 20A-1P 21 B 22 20A-1P SPARE
SPARE 20A-1P 23 C 24 20A-1P SPARE
SPARE 20A-1P 25 A 26 20A-1P SPARE
SPARE 20A-1P 27 B 28 20A-1P SPARE
SPARE 20A-1P 29 C 30 20A-1P SPARE
PANEL DP2 3/30/2023
LOCATION: ADVANCE WATER TREATMENT (AWT) NEMA: 1 PH A WEIGHTED VA 13334 VOLTS: 480 FEED: TOP PH B WEIGHTED VA 13334
PHASE & WIRE: 3 PH 3W MTG. SURFACE PH C WEIGHTED VA 13334 INTERRUPT: 65 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 40002
MAIN RATING: 100 AF 100 AT PANEL AMPS 48.1

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S I 1469 1 A 2 1719 I
I FCV-85211 & FV-85212 & FV-85214 - FILTER 1 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 3 B 4 15A-3P 1719 FV-85217 & FCV-85218 & FV-85219 - FILTER 1 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 5 C 6 1719 I
I 1469 7 A 8 1719 I
I FCV-85221 & FV-85222 & FV-85224 - FILTER 2 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 9 B 10 15A-3P 1719 FV-85227 & FCV-85228 & FV-85229 - FILTER 2 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 11 C 12 1719 I
I 1469 13 A 14 1719 I
I FCV-85231 & FV-85232 & FV-85234 - FILTER 3 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 15 B 16 15A-3P 1719 FV-85237 & FCV-85238 & FV-85239 - FILTER 3 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 17 C 18 1719 I
I 1469 19 A 20 1719 I
I FCV-85241 & FV-85242 & FV-85244 - FILTER 4 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 21 B 22 15A-3P 1719 FV-85247 & FCV-85248 & FV-85249 - FILTER 4 BACKWASH & EFFLUENT & AIR SCOUR VALVES I I 1469 23 C 24 1719 I
I 582 25 A 26
I FV-87130 - HIGH RATE BACKWASH VALVE 582 15A-3P 27 B 28 15A-3P SPARE I 582 29 C 30
31 A 32
SPARE 15A-3P 33 B 34 15A-3P SPARE
35 C 36
37 A 38
SPARE 15A-3P 39 B 40 15A-3P SPARE
41 C 42
P
lotD
ate: 05
-APR
-2023
3:18:03
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
04E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1004E01.dgn
JGB
PANELBOARD SCHEDULES 1
avates
111
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:21:49-07'00'
200

Page 350 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
# KEY NOTES:
3 2
4 1
1 1

4. EXISTING PANELBOARD IS SQUARE D TYPE NQOD.

3. EXISTING PANELBOARD IS SQUARE D TYPE NQOD.

ACCORDINGLY.

CHANGES TO PANEL CIRCUIT SCHEDULE IN THE FIELD

2. PROVIDE NEW CIRCUIT FOR THE NEW LOADS. REFLECT
PROVIDED PANEL BOARD SCHEDULE.

RELOCATE CIRCUIT BREAKERS AS NEEDED TO MATCH

1. RENAME THIS CIRCUIT IN THE PANEL CIRCUIT SCHEDULE.

PA PNL-A 3/9/2023
LOCATION: AWT BUILDING NEMA: 1 PH A WEIGHTED VA 8863
VOLTS: 208/120 FEED: TOP PH B WEIGHTED VA 9933
PHASE & WIRE: 3 PH 4W MTG. SURFACE PH C WEIGHTED VA 9496 INTERRUPT: 10 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 29798
MAIN RATING: 100 AF 100 AT PANEL AMPS 82.7

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C LTS-CONTROL/BLOWER ROOM 500 20A-1P 1 A 2 20A-1P 700 RCPT-CONTROL/BLOWER ROOM I C LTS-CHEMICAL FEED ROOM 1000 20A-1P 3 B 4 20A-1P 800 RCPT-CHEMICAL FEED ROOM I C LTS-AWT CLARIFIER/FILTER 1000 20A-1P 5 C 6 20A-1P 800 RCPT - AWT CLARIFIER/FILTER I C LTS-EXTERIOR 300 20A-1P 7 A 8 20A-1P 500 RCPT - AWT CLARIFIER/FILTER I C EF-5 CHEMICAL FEED 670 20A-1P 9 B 10 20A-1P 450 UH-6, UH-7, UH-8 C C EF-6 CHEMICAL FEED 670 20A-1P 11 C 12 20A-1P SPARE
C EF-7 CONTROL ROOM 670 20A-1P 13 A 14 15A-1P 1000 EWH-1 C C EF-8 BLOWER ROOM 670 20A-1P 15 B 16 20A-1P 1100 COAGULANT AID POLYMER FEEDER #1 C C AWT BUILDING CONTROL PANEL 1000 20A-1P 17 C 18 20A-1P 1100 COAGULANT AID POLYMER FEEDER #2 S C CAUSTIC LEAK PANEL 500 20A-1P 19 A 20 20A-1P 830 FILTER AID POLYMER FEEDER C C COAGULANT LEAK PANEL 500 20A-1P 21 B 22 20A-1P 1186 VCP-85183 - COAGULANT FEED CONTROL PANEL NO. 3 C C AIT-108/ AIT-109 200 20A-1P 23 C 24 20A-1P 1186 VCP-85182 - COAGULANT FEED CONTROL PANEL NO. 2 S C AIT-110/ AIT-111 200 20A-1P 25 A 26 20A-1P 1186 VCP-85181 - COAGULANT FEED CONTROL PANEL NO. 1 S SPARE 20A-1P 27 B 28 20A-1P 1100 CAUSTIC FEED PUMP #2 S C VCP-3 - AWT CLARIFIER/FILTER CONTROL PANEL 1000 20A-1P 29 C 30 20A-1P 1100 CAUSTIC FEED PUMP #1 C I LTG & RCPT AWT & BACKWASH PS 500 20A-1P 31 A 32 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 1 1130 20A-1P 33 B 34 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 2 1587 20A-1P 35 C 36 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 3 1130 20A-1P 37 A 38 20A-1P 300 HEAT TAPE C SPARE 20A-1P 39 B 40 20A-1P 300 HEAT TAPE C
SPARE 20A-1P 41 C 42 15A-1P 100 BINKLEY ALARM C
PANEL PNL70271 4/4/2023
LOCATION: DAFT BUILDING - MCC70271 NEMA: 1 PH A WEIGHTED VA 4568 VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 4173
PHASE & WIRE: 3 PH 4W MTG. MCC PH C WEIGHTED VA 3721
INTERRUPT: 10 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: CB EQUIP SIZING VA 13703
MAIN RATING: 100 AF 60 AT PANEL AMPS 38.0

I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C P60321 (PNL60321) 600 20A-1P 1 A 2 20A-1P 100 FIT7521 C C P60341 (PNL60341) 100 20A-1P 3 B 4 20A-1P 100 FIT7025 C C LTG-DIGESTERS 173 20A-1P 5 C 6 20A-1P 100 FIT7041 C
C RECPT-DIGESTERS 180 20A-1P 7 A 8 20A-1P 248 DAFT DECK LIGHTNING C C FIT6031 100 20A-1P 9 B 10 20A-1P 850 DAFT TANK LIGHTNING C C LIT6011 100 20A-1P 11 C 12 20A-1P 360 DAFT TANK RECEPTACLE I C PNL60301 600 20A-1P 13 A 14 20A-1P 650 DAFT BLDG INTERIOR LTG C C PNL60331 600 20A-1P 15 B 16 20A-1P 650 DAFT BLDG INTERIOR LTG C C FIT8001 100 20A-1P 17 C 18 20A-1P 720 DAFT BLDG INTERIOR RECEP I C FIT8002 100 20A-1P 19 A 20 20A-1P 720 DAFT BLDG INTERIOR RECEP I C MME60212 (AIT6004) 100 20A-1P 21 B 22 20A-1P 500 RESTROOM MINI WATER HTR C C NJB-60001 - ETHERNET SWITCH 100 15A-1P 23 C 24 20A-1P 100 LCP70272 C C FIT-99105 - METERING VAULT FLOW METER 100 20A-1P 25 A 26 20A-1P 500 PNL70241 C I CAROUSEL AND PAU RECEPTACLES 360 20A-1P 27 B 28 20A-1P 50 CV70261 C C CAROUSEL AND PAU LIGHTING 360 20A-1P 29 C 30 20A-1P 1080 PLC70299 C P
lotD
ate: 05
-APR
-2023
3:12:20
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
04E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1004E02.dgn
JGB
PANELBOARD SCHEDULES 2
112
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:39:21-07'00'
200

Page 351 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
DISCONNECT SCHEDULE 11/17/2022

TAG VOLTAGE POLES AMPS NEMA TYPE TYPE HORSEPOWER FUSE SIZE BREAKER AF/AT ACCESSORIES B 600 VAC 3P 30A 4X-SS NON-FUSED
E 600 VAC 3P 60A 4X-SS NON-FUSED 4
S 600 VAC 3P 200A 4X-SS NON-FUSED 4
T 600 VAC 2P 60A 4X-SS NON-FUSED
ACCESSORIES 1="B" TYPE ELECTRICAL INTERLOCK FOR POSITION INDICATION 2=INSULATED GROUNDABLE NEUTRAL KIT
3=DRAIN AND BREATHER KIT WHEN OUTDOORS
4=EARLY BREAK AUXILIARY CONTACT
LUMINAIRE SCHEDULE 3/8/2023

ITEM DESCRIPTION MOUNTING LAMP LUMINAIRE SPECIFICATIONS

METHOD QUANTITY TYPE MANUFACTURER CATALOG VOLTS VA
A

AUTOBAHN SERIES ATBM POLE LIGHT, ROADWAY TYPE III DISTRIBUTION FOUR-BOLT MAST ARM MOUNT FOR 1.25 TO 2 INCH OD POLE
w/ROUND TAPERED POLE WITH MOUNTING ARM

PROVIDE MOUNTING FOR TWO HEADS/ARMS ON A SINGLE POLE WHERE SHOWN COLOR TO MATCH EXISTING LIGHT POLES AND ANODIZED ALUMINUM, 12'-0" HIGH, 4" DIA 7 PIN INTEGRAL PHOTOCELL SENSOR AND CONTROL WITH DIMMABLE DRIVE

PROVIDE EMBEDDED GFCI RECEPTACLE WITH WEATHER PROOFING COVER WHERE SHOWN POLE
MOUNT
N/A
LED
4000 CCT
10,675 LUMENS

AMERICAN

ELECTRIC

LIGHTING
ATBM P10 MVOLT R3 4B UMR-XX P7 120 81
B

SEALED, AND GASKETED LED LUMINAIRE, CLEAR POLYCARBONATE LENS 80 CRI, SUITABLE FOR WET LOCATIONS, w/ HIGH EFFICIENCY LEDs FOR AMBIENT TEMPERATURES -29 TO 40 DEG C, L80 AT 75,000 HOURS

CALIFORNIA ENERGY CODE COMPLIANT BUILT-IN EMERGENCY BACKUP WHERE SHOWN

CEILING MOUNT

OR SUSPENDED

AS NEEDED
N/A
LED
4000K CCT
6,643 LUMENS
HOLOPHANE EVT4 6000LM PCL WD MVOLT 40K 80 120 71
C

DELEON TL SINGLE FACE EXIT SIGN, UL WET LOCATION LISTED, SELF DIAGNOSTICS AMBIENT TEMPERATURES -40 TO 45 DEG C
DUAL VOLTAGE 120/277 w/GREEN EXIT LETTERS

SELF-CONTAINED, SEALED MAINTENANCE FREE NICKEL CADMIUM BATTERIES WALL

OR CEILING
MOUNT
N/A LED HOLOPHANE LNTLL NC W SG S 120 4.8
D

BUILDING-MOUNTED LUMINAIRE WITH ALUMINUM HOUSING SEALED AGAINST

MOISTURE AND ENVIRONMENTAL CONTAMINANTS
70 CRI, TYPE IV LIGHT DISTRIBUTION, HIGH EFFICIENCY LEDs w/ MOTION/AMBIENT LIGHT SENSOR, DARK BRONZE WITH BATTERY PACK

WALL MOUNT N/A
LED
4000K CCT
2,000 LUMENS

LITHONIA
MRW LED P1 40K SR4 MVOLT PIR DDBXD
E20WC
120 28.8
ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE 4/3/2023
TAG NO

MINIMUM INTERIOR

DIMENSIONS (INCHES) CONSTRUCTION

TYPICAL
DETAIL

SURFACE

LOADING

COMMENTS

WIDTH LENGTH DEPTH
COUED-4 60 60 48 60" ROUND PRECAST ROADWAY COUED "504" CUSTOM CONSTRUCTION FOR MV VAULT HH-1 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-2 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-3 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-4 52 52 62 PRECAST CONCRETE EM056 SIDEWALK
HH-10 52 52 62 PRECAST CONCRETE EM056 ROADWAY
HH-11 44 44 54 PRECAST CONCRETE EM056 ROADWAY
MH-12 60 60 84 PRECAST CONCRETE EM062 ROADWAY
HH-13 44 44 54 PRECAST CONCRETE EM056 ROADWAY
HH-20 48 48 54 PRECAST CONCRETE EM056 ROADWAY
HH-21 48 48 54 PRECAST CONCRETE EM056 ROADWAY
NOTES:

1. SEE SPECIFICATION 02581 FOR PRECAST ELECTRICAL HANDHOLES AND MANHOLES.

2. ALTERNATES: PROVIDE PER TYPICAL DETAIL EM062 IF INDICATED UNDER "COMMENTS".

P
lotD
ate: 05
-APR
-2023 1:21:58
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
05E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1005E01.dgn
JGB
# KEY NOTES:

EFFICIENCY STANDARD SECTION 130.0(c).

1. LUMINAIRE SHALL BE FACTORY LABELED PER 2019 BUILDING 1 AND DISCONNECT SCHEDULES

LUMINAIRE, MANHOLE/HANDHOLE,
avates
113
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:31:43-07'00'
200

Page 352 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 3:12:41PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 05E02
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1005E02.dgn
TITLE 24 COMPLIANCE SHEETS 1
114
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:08-07'00'
200

Page 353 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 2:35:49PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 05E03
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1005E03.dgn
TITLE 24 COMPLIANCE SHEETS 2
115
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:25-07'00'
200

Page 354 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 2:36:14PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 05E04
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL
8660F10 8660F1005E04.dgn
TITLE 24 COMPLIANCE SHEETS 3
116
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:40-07'00'
200

Page 355 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023
2:29:10
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
12E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL

POWER GENERATION BUILDING
8660F10 8660F1012E01.dgn
A
01E02
#
GENERAL NOTES:

KEY NOTES:

TYP
EM902
1 TYP
EM173
(TYP)
PLC12199
ANT1-99400 N-5100 2 RAD1-99400 3 N-5000 2

PARTIAL COMMUNICATION PLAN
8660F1012E0101
avates
INSTALLATION.

ADDITIONAL INFORMATION WITH REGARDS TO RADIO EQUIPMENT

2. REFER TO NETWORK BLOCK DIAGRAM DRAWING 04N01 FOR
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PANEL MINIMUM DIMENSIONS SHALL BE 20" H x 20" W x 12" D.

DIMENSIONS AND MANUFACTURER RECOMMENDATIONS. RADIO
OWNER. SIZE RADIO PANEL ACCORDING TO RADIO EQUIPMENT

3. COORDINATE THE EXACT LOCATION FOR RADIO PANEL WITH
ACCORDING TO EA080/TYP.

2. SUPPORT CONDUIT ON WALL WITH PREFORMED CHANNEL
PROVIDE MINIMUM TWO POINT OF SUPPORT FOR MAST POLE.

CHANNEL. WALL ATTACHMENT SHALL BE ACCORDING TO EA080/TYP.

1. MOUNT ANTENNA MAST POLE ON WALL WITH PREFORMED
117
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:32:56-07'00'
200

Page 356 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
B
B
P
lotD
ate: 05
-APR
-2023 1:21:50
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
60E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1060E01.dgn

DECHLORINATION STRUCTURE

POWER, CONTROL AND LIGHTING PLAN

STRUCTURE

DECHLORINATION
LCP-60102
DISC-60102
FV-60102
FV-60100
DISC-60100
LCP-60100
A
12'-0"
GENERAL NOTES:

GFCI-WP
A
01E02 3/8" = 1'-0"
# KEY NOTES:

AIT-60101 5
1 3
4 PB-6001
P-60-105
N-60-105
TYP
EM015
P-60-106
C-60-105
2 L-60-110
TYP
EM103
TYP
EM001
TYP
EM211
(TYP)
P-60-107
L
02E02
DWG 01E02

CONTINUED ON
N-60-100
P-60-100
C-60-100
P-60-101
P-60-102
TYP
EL507
PBL70271-29
PNL70271-27
NJB-60001
JGB
SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 3/4".

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

5. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
IN THE SAME RACEWAY FOR VOLTAGE DROP.

AND SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS

BE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,

4. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

3. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS CONDUITS AND WIRING IN A SIMILAR MANNER.

ROUTING AS A GUIDE TO INSTALL LIGHTING AND RECEPTACLE
SHOWN. USE THE PROCESS POWER AND CONTROL CONDUIT

2. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER 8660F1060E0101
AND SIGNAL CIRCUITS TO THE NEW UNIT.

EQUIPMENT MOUNTING STAND, AND RECONNECT EXISTING POWER

5. MOUNT NEW ANALYZER UNIT INSIDE THE EXISTING CABINET, ON JUNCTION BOX ACCORDING TO NEC.

INTERNAL WIRING AND DEVICE INFORMATION. SIZE NETWORK

4. REFER TO DRAWING 04N03 FOR NETWORK JUNCTION BOX
NEC. PULL BOX MINIMUM SIZE SHALL BE 12'W X 8"D X 12"H.

3. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO

2. TO LIGHTING FIXTURES AND RECEPTACLES.

DETAIL EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO

1. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING L-60-111
P-60-120
X-60-100
N-60-110
X-60-105
avates
L-60-109
118
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:39:06-07'00'
200

Page 357 of 1800 ends

PB-7001
PB-7002
#4/0 SDBC

STATION

SCADA CONTROL

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
P
lotD
ate: 05
-APR
-2023
2:27:15
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
70E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

AB
ASH

ELECTRICAL
8660F10 8660F1070E01.dgn
MCC70292
MCC70291
MCC70293

ELECTRICAL ROOM

RESTROOM
FUTURE
GENERAL NOTES:

DAFT BUILDING ELECTRICAL ROOM
4 TYP
(TYP)
X-89-111
X-89-113
C-89-120
P-89-121
P-89-111
P-89-101
L-89-113
P-89-133
C-91-111
P-91-101
1 TYP
(TYP)
EM001
TYP
EM020
(TYP)
2 S-89-102
X-89-103
EM173
L-89-114
C-91-112
P-91-102
P-89-121
P-89-111
C-89-120
P-89-101
P-89-134
S-89-103
TYP
EM102
(TYP)
C-89-140
C-89-132
C-89-131
C-89-130
N-70-101
N-70-102
N-70-103
N-70-100
N-70-104
S-80-101
C-87-103
P-89-136
P-89-135
P-89-105
P-89-115
P-91-105
P-89-125
X-80-100
X-80-101
1 4
M
02E03
DWG 01E02

CONTINUED ON
TYP
EM105
4 D
W
G 01
E02
CON
TINU
ED ON
K
02E02
VFD-89102
VFD-89101
VFD-89100
VFD-91100
PLC70299
SWB70282
SWB70281
TYP
(TYP)
EG101
# KEY NOTES:

A
01E02 1/4" = 1'-0"
8660F1001E0101
N-60-113
N-60-114
JGB
1 1
3 S350/TYP.

MOUNTED ELECTRICAL EQUIPMENT ACCORDING TO DETAIL

2. PROVIDE EQUIPMENT HOUSEKEEPING PAD FOR NEW FLOOR
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PER DETAIL EG152/TYP.

DETAIL EG101/TYP AND EXOTHERMIC CONNECTION SHALL BE
CONNECTIONS. COMPRESSION CONNECTION SHALL BE PER

CABLE CONNECTION TYPE AND FOLLOW IT TO MAKE THE NEW
RING AND BOND NEW EQUIPMENT TO IT. VERIFY EXISTING

4. FIELD VERIFY AND LOCATE EXISTING GROUNDING ELECTRODE CONDUCTORS INSTALLATION.

EXISTING CIRCUITS IN PLACE DURING NEW CONDUITS AND

3. EXISTING SIGNAL AND COMMUNICATION PULL BOX. PROTECT
BUILDING.

MOUNT PULL BOX ON THE EXTERIOR WALL OF THE DAFT
NEC. PULL BOX MINIMUM SIZE SHALL BE 36"W X 26"D X 36"H.

2. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO ACCORDING TO DETAIL EM219/TYP.

TRANSITIONING BETWEEN DUCT BANK TO EXPOSED ROUTING

1. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS

POWER, CONTROL, AND GROUNDING PLAN
avates
119
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:33:13-07'00'
200

Page 358 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:23:21
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
80E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HR
SMB

ELECTRICAL
8660F10 8660F1080E01.dgn
A
01E02
LIT-80100
GENERAL NOTES:

SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PB-8001
TYP
EM103
TYP
EM001
S-80-100
S-80-101
X-80-100
X-80-101
D
W
G 01
E02
CON
TINU
ED ON
2 1
M
02E03
# KEY NOTES:

JGB
evandoorn
STRUCTURE 80 PLAN
8660F1080E0101

NO SCALE
ACCORDING TO DETAIL EM219/TYP.

TRANSITIONING BETWEEN DUCT BANK TO EXPOSED ROUTING

2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS
10"D X 18"H.

ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 18"W X

1. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
120
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:38:39-07'00'
200

Page 359 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
PlotDate: 05-APR-2023 2:25:12PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 85E01
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1085E01.dgn
A
01E02
8660F1085E0101
C
85E02 85E03 B

AWT BUILDING OVERALL PLAN
3/16" = 1'-0"
JGB
121
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:33:28-07'00'
200

Page 360 of 1800 ends

HMI WORKSTATION

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
J
J
J
P
lotD
ate: 05
-APR
-2023 1:20:01
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1085E02.dgn
AWT BUILDING POWER AND CONTROL PLAN 1
M
ATC
H
LIN
E
SEE
D
W
G 85E03
B
85E01
8660F1085E0101
MCC-C
PCM-4
PNL-A
XFMR-A
DP2

STATION
WORK
PMP-85104
PMP-85183
VCP-85183
LCP-85104
S-85-540
C-85-542
C-85-550
S-85-475
S-85-415
C-85-402
C-85-457
P-85-221
P-85-421
C-85-401
S-85-411
C-85-145
P-85-275
P-85-475
C-85-455
S-85-471
C-85-614
C-85-620
C-85-616
PB-8502
PB-8501
PB-8530
2 3
2 P-85-501
C-85-510
C-85-520
C-85-530
S-85-510
S-85-520
S-85-530
C-85-501
C-85-507
C-85-503
C-85-505
C-85-511
C-85-517
C-85-515
C-85-513
P-85-521
C-85-523
C-85-521
P-85-511
C-85-525
C-85-527 C-85-540
P-85-710
P-85-612
C-85-612
P-85-610
C-85-610
1 1
TYP
EM201
TYP
(TYP)
EM102
TYP
(TYP)
EM163
4 JGB
N-85-500
N-85-510
1/4" = 1'-0" -
1 1/2" = 1'-0"
8660F1085E0101
PDSH-85106
BLO-85106
FAN-85109
LCP-85108
FAN-85111
BLO-85108
PDSH-85108
PSH-85108
PIT-85108
LCP-85106
PSH-85106
PIT-85106
PIT-85107
PSH-85107
LCP-85107
PDSH-85107
BLO-85107
FAN-85110
PSL-85100
1 -
P-85-477
P-85-277
P-85-422
P-85-222
C-85-542
P-85-501
P-85-511
P-87-115
C-87-115
S-88-110
L-88-105
C-85-545
P-85-521
C-87-119
P-87-117
P-87-117
S-88-112
C-85-545
S-85-540
VERIFY WHERE NEEDED.

FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL FIELD

DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND SIZES

1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
#
WORK.

CONDUIT, CONDUCTORS, AND SWITCH BOXES TO COMPLETE THE
PANELBOARD. PROVIDE ALL THE NECESSARY EQUIPMENT SUCH AS

4. RELOCATE EXISTING LIGHTING SWITCH TO MAKE ROOM FOR NEW X 12"H.

ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D

3. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
NEC. PULL BOX MINIMUM SIZE SHALL BE 20"W X 12"D X 20"H.

2. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO CONDUCTORS TO THE NEW EQUIPMENT.

EXISTING POWER, CONTROL, AND SIGNAL CONDUITS AND
LOCATED INSIDE VENDOR CONTROL PANEL WITH NEW. RECONNECT

1. REPLACE EXISTING PUMP LOCATED ON PEDESTAL AND PUMP DRIVE GENERAL NOTES:

KEY NOTES:
avates
VCP-3
122
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:38:22-07'00'
200

Page 361 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
B

J B B B J B B B B B J B J B B B

B B J B B J B J
B
B J
B
B

J J J J
B B
P
lotD
ate: 05
-APR
-2023
2:23:56
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
85E03
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
EYJ

ELECTRICAL
8660F10 8660F1085E03.dgn
AWT BUILDING POWER AND CONTROL PLAN 2
M
ATC
H
LIN
E
SEE
D
W
G 85E02
C
85E01
8660F1085E0101
DISC-85248
DISC-85249
FV-85249
FCV-85248
FV-85247
FV-85239
FV-85237
FV-85217
FCV-85218
LSH-85104
LSH-85103 LSH-85102 LSH-85101
DISC-85241
DISC-85232
DISC-85231
DISC-85221
DISC-85222
DISC-85211
DISC-85212
FV-85222
FV-85212
FCV-85221
FCV-85241 FCV-85231
FV-85242
FCV-85211
LSL-85104
LSL-85103 LSL-85102 LSL-85101
DISC-85247
PB-8514
DISC-85239
DISC-85237
DISC-85238
PB-8513 PB-8512
FV-85219
PB-8511
DISC-85219
DISC-85217
DISC-85218
DISC-85227
DISC-85228
FV-85227
DISC-85229
FCV-85228
FV-85229
FV-85244 FV-85234 FV-85224 FV-85214
PB-8524
PB-8523
PB-8522
PB-8521
DISC-85214
DISC-85244 DISC-85234 DISC-85224
P-85-400
P-85-405
S-85-405
S-85-410
P-85-410
P-85-420
C-85-400
P-85-406
P-85-401
P-85-411
P-85-300
P-85-305
S-85-305
P-85-310
P-85-320
C-85-300
S-85-311
C-85-133
C-85-301
P-85-306
P-85-311
P-85-301
P-85-201
P-85-220
C-85-200
S-85-210
P-85-206
P-85-200
P-85-210
C-85-201
S-85-211
C-85-123
P-85-205
S-85-205
P-85-100
P-85-105
S-85-105
P-85-110
S-85-110
P-85-101
P-85-111
P-85-106
P-85-120
C-85-100
C-85-111
C-85-110
C-85-112
C-85-121
C-85-120
C-85-122
C-85-131
C-85-130
C-85-132
C-85-141
C-85-140
C-85-142
FILTER NO. 4 FILTER NO. 3 FILTER NO. 2 FILTER NO. 1
CLARIFIER NO. 4 CLARIFIER NO. 3 CLARIFIER NO. 2 CLARIFIER NO. 1 P-85-150
P-85-155
P-85-160
S-85-150
S-85-170
C-85-150
P-85-170
P-85-161
S-85-270
P-85-156
P-85-151
P-85-260
P-85-261
P-85-250
S-85-250
P-85-255
P-85-256
P-85-251
S-85-271
C-85-251
C-85-250
S-85-370
P-85-360
P-85-361
P-85-355
P-85-350
P-85-351
P-85-356
S-85-371
C-85-351
S-85-350
P-85-370
S-85-470
P-85-460
P-85-461
P-85-455
P-85-450
P-85-451
P-85-456
P-85-470
C-85-450
S-85-450
#
GENERAL NOTES:

KEY NOTES:
1 3
4 6 6
6 TYP (TYP)
EM211

TYP (TYP)
EM221
6 6
5 5
4 5
6 6
5 6
1 2
JGB
7 7 7 7
P-85-221
P-85-421
C-85-401
S-85-411
C-85-145
P-85-275
P-85-475
C-85-455
S-85-471 TYP
EM102
FCV-85238
P-85-211
S-85-310
DISC-85242
FV-85232
C-85-350
1/4" = 1'-0"
P-85-270
C-87-115
S-88-110
P-87-115
S-85-400
LIT-85241 LIT-85221 LIT-85211
S-85-300 S-85-200
LIT-85231
S-85-100
P-87-112
C-87-110
C-87-101
P-87-101
S-88-105
S-87-100
PB-8535
R
02E03
8 9 PB-8530
10 ELECTRICAL AND PROCESS EQUIPMENT.

MAINTENANCE AND REPAIR IS PROVIDED AROUND AWT FILTER

THE OWNER AND ENSURE ADEQUATE SPACE FOR

2. COORDINATE EQUIPMENT MOUNTING STAND LOCATIONS WITH
FIELD VERIFY WHERE NEEDED.

SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL

DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND

1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
avates
TYP
EM102
8"D X 12"H.

ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X

10. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D X 12"H.

9. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING

8. DUCT BANKS CONTINUES ONTO DRAWING 01E02.

STRIPS INSIDE THE JUNCTION BOX.

CONTRACTOR PROVIDED CONDUCTORS, USING TERMINAL
FILTER WALL. TERMINATE LEVEL FLOAT SWITCH CABLE TO

7. PROVIDE A TERMINATION JUNCTION BOX, MOUNTED AT TOP
TO PANELBOARD DP2 SCHEDULE.

INSIDE PULL BOX, TO FEED ASSOCIATED ACTUATOR ACCORDING

PANELBOARD SHALL SPLICE TO THREE DIFFERENT CIRCUITS

ACTUATOR POWER FEEDER CIRCUIT COMING FROM
TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D X 12"H.

6. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING
WITH PREFORMED CHANNEL ACCORDING TO DETAIL EA030/TYP.

5. MOUNT DISCONNECT SWITCH ON THE FILTER EXTERIOR WALL
WASTE GATES.

ASSOCIATED WITH ALL FILTERS, LEVEL INSTRUMENTS, AND
FILTER EXTERIOR WALLS. THIS IS TYPICAL FOR CONDUITS

4. SUPPORT CONDUITS WITH PREFORMED CHANNELS ON THE
THE FILTER EXTERIOR WALL ACCORDING TO DETAIL EA030/TYP.

EM104/TYP. OR SUPPORTED WITH PREFORMED CHANNEL ON

SUPPORTED ON THE GROUND ACCORDING TO DETAIL

3. CONDUIT ROUTING ON THE EAST SIDE OF FILTERS SHALL BE CHANNEL ACCORDING TO DETAIL EA060/TYP.

SUPPORTED UNDER THE PLATFORM WITH PREFORMED

2. CONDUIT ROUTING ON THE WEST SIDE OF FILTERS SHALL BE CEILING LEVEL.

1. CONDUITS FROM THE WEST SIDE OF TANK SHALL RISE TO
123
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:29:00-07'00'
200

Page 362 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
J
P
lotD
ate: 05
-APR
-2023
2:20:27
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
87E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1087E01.dgn
A
01E02
8660F1087E0101

POWER AND CONTROL PLAN

BACKWASH PUMP STATION
GENERAL NOTES:

VERIFY WHERE NEEDED.

FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL FIELD

DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND SIZES

1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD

NO SCALE
# KEY NOTES:

AIT-87130
PMP-87134
LCP-87134
2 TYP
(TYP)
P
02E03
EM001
S-87-100
C-87-101
P-87-101
C-87-100
P-87-100
TYP
EM104
1 TYP (TYP)
EM201
JGB
avates
3 DWG01E02

CONTINUED ON
DWG01E02

CONTINUED ON
3 Q
02E03
TYP
(TYP)
EM015
L-88-102
L-88-101
S-88-102
S-88-101

3. GROUND NEW DUCT BANK TO EXISTING GROUND RING.

DETAIL EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO

2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING CONDUCTOR TERMINATION POINT.

CONDUCTORS AS LONG AS NEEDED TO REACH EQUIPMENT
CIRCUITS TO THE NEW UNIT. EXTEND POWER CONDUITS AND

EQUIPMENT MOUNTING STAND, AND RECONNECT EXISTING POWER

1. MOUNT NEW ANALYZER UNIT ON THE EXISTING ANALYZER
D
W
G01
E02
CON
TINU
ED ON
FV-87130
C-87-105
FV-87130
124
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:35:15-07'00'
200

Page 363 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
JJJ
J
PlotDate: 05-APR-2023 2:16:59PM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 89E01
LASTSAVED BY:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1089E01.dgn
A
01E02 1/2"=1'-0"
8660F1089E0101
DW G 01E02

CONTINUED ON
DWG 01E02

CONTINUED ON
02E01
# KEY NOTES:
1 33
5 4
PMP-89100
LCP-89100
LCP-89101
PMP-89101
LCP-89102
PMP-89102
PB-8901
GENERAL NOTES:

I
02E02 L
TRF-3E

CAROUSEL PUMP STATION

POWER AND CONTROL PLAN
X-89-100
P-89-131
P-89-101
P-89-111
P-89-121
C-89-120
L-89-111
S-89-101
X-89-101
2 L-60-111
P-60-120
X-60-100
N-60-110
2 C-89-120
S-89-100
L-89-110
L-89-120
P-89-130
P-89-100
P-89-110
TYP P-89-120
(TYP)
EM020

TYP (TYP)
EM211

TYP (TYP)
EM104
C-89-101
C-89-102
C-89-100
3 FSL-89102
C-89-108
C-89-113

TYP (TYP)
EM201
C-89-116
C-89-115
C-89-111
C-89-110
LIT-89103
LSLL-89100
C-89-106
C-89-107
FSL-89101
FSL-89100
X-89-120
X-89-125
N-60-111
X-60-105
-1 KVA TRANSFORMER
- MOTOR CONTROL CABINET
- MAIN DISCONNECT SWITCH, 200 A, 3-POLE
ELECTRICAL EQUIPMENT TO BE DEMOLISHED:

2. REFER TO DRAWING 89D01 FOR LOCATION OF FOLLOWING
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER

TYP (TYP)
EM105
JGB

6. TO LIGHTING FIXTURES AND RECEPTACLES.

CONDUCTORS ON LINE SIDE OF DISCONNECT SWITCH.

DIVERSION METERING VAULT FLOW METER FIT-99105. TERMINATE

5. DISCONNECT SWITCH IS FOR 120V POWER SOURCE TO FLOW
CONDUCTORS ON LINE SIDE OF DISCONNECT SWITCH.

DIVERSION METERING VAULT ACTUATED VALVES. TERMINATE

4. DISCONNECT SWITCH IS FOR 480V POWER SOURCE TO FLOW

3. REPLACE EXISTING PUMP MOTOR WITH NEW MOTOR.

DETAIL EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO

2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING EAST.

POWER/CONTROL CIRCUITS. ACCESS DOORS SHALL BE FACING

PULLING SPACE BETWEEN SIGNAL/COMMUNICATION AND

BOX WITH SEPARATE ACCESS DOORS AND SEPARATE THE CABLE
SHALL BE 30"W X 20"D X 30" H. PROVIDE A DIVIDER INSIDE THE PULL PULL BOX ACCORDING TO NEC. PULL BOX MINIMUM DIMENSIONS

1. POWER, CONTROL, SIGNAL AND COMMUNICATION PULL BOX. SIZE DW G 01E02

CONTINUED ON
6 TYP
EM020
(TYP)
2 avates
LSHH-89100
125
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:21:06-07'00'
200

Page 364 of 1800 ends

#6 SDBC
#4/0 SDBC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:20:37
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
89E02
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1089E02.dgn
B
01E02 1/2"=1'-0"
8660F1089E0201
D
W
G 01
E02
CON
TINU
ED ON
DWG 01E02

CONTINUED ON
02E01
PMP-89100
PMP-89101
PMP-89102
GENERAL NOTES:

I
02E02
L
TRF-3E

CAROUSEL PUMP STATION LIGHTING,

TYP (TYP)
EG002
TYP
EG204
TYP
EG101
(TYP)

GFCI-WP
A
12'-0"

GFCI-WP
A
12'-0"
2 TYP
EG001
(TYP)
# KEY NOTES:

GROUNDING EQUIPMENT ARE NOT IN ADEQUATE CONDITION.

THE EXISTING GROUND RING AND GROUND RODS IF EXISTING
GROUND RING ASSOCIATED WITH THE PUMP STATION. REPLACE

5. FIELD VERIFY CONDITION, LAYOUT AND INTEGRITY OF THE EXISTING INCHES.

SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.

SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND

3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN. evandoorn
1 1
PNL70271-27
PNL70271-29
PNL70271-29
PNL70271-27
JGB

GROUNDING, AND RECEPTACLES PLAN

2. TYPICAL FOR ALL CAROUSEL PUMP MOTOR.

CONDUCTOR ACCORDING TO DETAIL EG101/TYP.

1. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
126
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:29:17-07'00'
200

Page 365 of 1800 ends

#4/0 SDBC
PB-9101

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
P
lotD
ate: 05
-APR
-2023
2:11:46
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
91E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
ASH

ELECTRICAL
8660F10 8660F1091E01.dgn
A
01E02
8660F1091E0101

POWER AND CONTROL
PMP-91100
B
01E02
8660F1091E0201
A
12'-0"

GFCI-WP
3/8"=1'-0" 3/8"=1'-0"
H
3 LSHH-91101
LSL-91101
L-91-100
X-91-102
C-91-105
C-91-106
P-91-101
C-91-110
X-91-100
LCP-91100
02E01
TYP
TYP
(TYP)

TYP (TYP)
TYP
TYP
TYP
EM020
EM105
EM211
EM115
EG001
EL507
TYP
(TYP)
EG101
TYP
(TYP)
EG002
PMP-91100
1 2
3 FSL-91100
DWG 01E02

CONTINUED ON
DWG 01E02

CONTINUED ON
TYP
EM201
C-91-104
TYP
EM139
PNL70271-27
PNL70271-29

LIGHTING AND GROUNDING
JGB

PAU PUMP STATION PLANS
C-91-100
P-91-100
avates
INCHES.

SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THE 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.

SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND

3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN, #
CONDUCTOR AS PER DETAIL EG101/TYP.

4. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
EM219/TYP.

BETWEEN DUCT BANK TO EXPOSED ROUTING AS PER DETAIL

3. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING NEC. PULL BOX MINIMUM SIZE SHALL BE 22"W X 12"D X 22" H.

2. POWER AND CONTROL PULL BOX SIZE PULL BOX ACCORDING TO

1. TO LIGHTING FIXTURES AND RECEPTACLES.

GENERAL NOTES:

KEY NOTES:
4 H
02E01
127
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:24:10-07'00'
200

Page 366 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023 1:53:54
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E01
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL

EXISTING WATER TREATMENT BUILDING
8660F10 8660F1099E01.dgn
A
02E01
XFMR-A
GEN-A
MCC-E
ATS-E

MCC-XFR

VFD-XFR
MCC-N
SWBD-A
ROOM

ELECTRICAL
JGB
# KEY NOTES:

PNL-RWPS
2 1
-
-

PNL-RWPS
1 2
1 1
-
MCC-E
2 -

PNL-RWPS
X-0010
X-0011
P-0010
P-0011
3 4
6 TYP
EM001
P-0001
P-0002
5 6
3 -
8660F1099E01C

ELECTRICAL ROOM ATTIC
7 7
GENERAL NOTES:
3 -
SHALL FIELD VERIFY WHERE NEEDED.

AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR

RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS

1. EXISTING EQUIPMENT LOCATION AND SIZES ARE FROM OWNER

PARTIAL POWER AND CONTROL PLAN
8660F1099E01A 8660F1099E01B
WORK RESTRICTIONS.

CONDUIT WORK. REFER TO SPECIFICATION SECTION 01140 FOR
CONDUITS. PROTECT EXISTING CABLES AND RE-TERMINATE AFTER

7. IF NEEDED FOR TOP HAT CONSTRUCTION, RELOCATE EXISTING STRUCTURAL ENGINEER OF RECORD FOR DIRECTION.

MODIFICATION TO CEILING JOISTS IS NEEDED, CONTACT

MOUNTING SPACE IS OBSTRUCTED BY CEILING JOISTS, AND

DETERMINED DURING FIELD VERIFICATION THAT ENCLOSURE
CONDUIT ENTRY, AND ACCESS LOCATION WITH EATON. IF IT IS JOISTS. COORDINATE NEW TOP HAT ENCLOSURE ACTUAL SIZE,
THAN 8" MAY NEED TO BE PARTIALLY PLACED IN CEILING, BETWEEN

6. HEAD SPACE ABOVE MCC IS APPROXIMATELY 8". TOP HAT HIGHER ROOM. SUPPORT CONDUITS IN ATTIC SPACE PER DETAIL EM901/TYP.

5. ROUTE CONDUITS THROUGH ATTIC SPACE ABOVE ELECTRICAL
CHANNELS ACCORDING TO DETAIL EM903/TYP.

4. SUPPORT CONDUITS ON BUILDING SIDE WALL WITH PREFORMED ELECTRICAL BUILDING.

EM219/TYP, AND ENTER TO THE BUILDING'S ATTIC SPACE, ABOVE

3. CONDUITS RISE FROM DUCT BANK PER DETAIL EM020/TYP AND SPACE FOR PNL-RWPS INSTALLATION.

2. RELOCATE SPD ENCLOSURE IF NEEDED TO PROVIDE ADEQUATE SHALL SUBMIT TOP HAT AND TAP DESIGN FOE ENGINEER REVIEW.

SERVICES TO COMPLETE TOP HAT INSTALLATION. CONTRACTOR
MCC-E. CONTRACTOR TO PROVIDE MANUFACTURER FIELD

PARTS AND ACCESSORIES TO COMPLETE CABLE TERMINATION IN
BE THE SAME AS EXISTING MCC-E. PROVIDE ALL THE NECESSARY POWER CABLES. ENCLOSURE MANUFACTURER AND MODEL SHALL

ACCOMMODATE NEW TAP OF EXISTING MCC-E BUS WITH PNL-RWPS

1. PROVIDE MCC TOP HAT ENCLOSURE TO HOUSE PNL-RWPS POWER.

DWG 01E01

CONTINUED ON
A
01E01 1/4" = 1'-0"
8660F1099E0101
128
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:34:05-07'00'
200

Page 367 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
B
B
P
lotD
ate: 05
-APR
-2023 1:20:25
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1099E02.dgn
99E02
# KEY NOTES:
1 PNL-RWPS-L XFMR-RWPS-L
PCM-99400
SWBD-RWPS VFD-99414 VFD-99413 VFD-99412 VFD-99411

RECYCLED WATER ELECTRICAL BUILDING

POWER AND CONTROL PLAN
JGB
CON
TINU
ED ON
D
W
G 99E03
A CONTINUED ON DWG 01E01
02E01
C
02E01
TYP
(TYP)
EM001
3 X-3200
X-3100
X-3104
X-2100
X-1502
P-2012
C-2015
S-2011
X-2011
P-2022
C-2025
S-2021
X-2021
N-2021
P-2032
C-2035
S-2031
X-2031
P-2042
C-2045
S-2041
X-2041
N-2041
X-2056
X-2052
X-2053
X-2054
X-2051
X-2055
P-2043
P-2033
P-2023
P-2013
TYP
EM020
TYP
(TYP)
EM022 2
N-2011
P-0010
P-0011
P-1000
X-0010
X-0011
L-1102
DISC-99421
L-1101
CU-99421
L-1110
L-1100
CU-99422
TYP
EM173
DISC-99422
L-1112
L-1111
TYP
EM107

TYP (TYP)
EM033
N-3100
N-1000
RAD2-99400
S-3102
L-1000
C-3105
L-3200
L-3102
L-2100
X-2101
L-1200
L-1201
N-2031
GENERAL NOTES:

S-2431
L-2431
X-1501
X-1500
N-2001
5 5
4 EM102/TYP AND EA030/TYP.

3. SUPPORT EXPOSED CONDUITS AS NEEDED ACCORDING TO DETAILS BOTTOM OF ENCLOSURE.

ROOM WITH ELECTRICAL EQUIPMENT CONDUIT ENTRY OPENING AT

2. COORDINATE CONDUIT STUB UP LOCATIONS INSIDE ELECTRICAL CROSS IN CONCRETE SLAB.

DIAMETER LARGER THAN TWO INCHES SHALL NOT STACK OR
EM115/TYP, EM116/TYP, AND EM117/TYP. EMBEDDED CONDUITS WITH

1. EMBEDDED CONDUIT IN SLAB SHALL BE INSTALLED PER DETAILS B
01E01 3/4" = 1'-0"
8660F1099E0101
FCU-99421 FCU-99422
S-3101
C-3102
6 DIMENSIONS SHALL BE 20" H x 20" W x 12" D.

AND MANUFACTURER RECOMMENDATIONS. RADIO PANEL MINIMUM

6. SIZE RADIO PANEL ACCORDING TO RADIO EQUIPMENT DIMENSIONS ANY CHANGES TO ENGINEER FOR REVIEW.

BREAKER RATING AND CABLE SIZE ACCORDINGLY PER NEC. SUBMIT

PROTECTION RATING FOR HVAC UNIT, AND CHANGE CIRCUIT

5. CONTRACTOR SHALL VERIFY MAXIMUM OVER CURRENT
MANUFACTURER INSTALLATION REQUIREMENTS.

NECESSARY CONDUITS AND CABLES ACCORDING TO

4. CONTRACTOR SHALL INSTALL THERMOSTAT, AND PROVIDE
BUILDING SLAB AND TOP OF THE DUCT BANK.

3. PROVIDE MINIMUM OF 6" SPACE BETWEEN BOTTOM OF THE
LOCATION.

2. CONDUITS SHALL REMAIN ENCASED IN DUCT BANK TO STUB UP

1. SPACE IS RESERVED FOR FUTURE RECYCLED PUMP VFD.
avates
X-3101
129
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:38:09-07'00'
200

Page 368 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
S
J
S
J
S
J
S
J
P
lotD
ate: 05
-APR
-2023 1:19:28
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
CLH

ELECTRICAL
8660F10 8660F1099E03.dgn

RECYCLED WATER PUMP STATION
99E03
LCP-99411 PMP-99411 PMP-99412 PMP-99413 PMP-99414
FIT-99431

POWER AND CONTROL PLAN
FSL-99411 FSL-99412 FSL-99413 FSL-99414
JGB
DISC-99411
P-2012
S-2011
X-2011
C-2015
C-2019
TYP
(TYP)
EM202
1 TYP
(TYP)
EM020
2 TYP
EM032
3 C
02E01
D
02E01
L-2100
C-2013
C-2012
C-2011
P-2011
DISC-99412
P-2022
S-2021
X-2021
C-2025
C-2029
C-2023
C-2022
C-2021
LCP-99412
DISC-99413
P-2032
S-2031
X-2031
C-2035
C-2039
C-2033
C-2032
C-2031
LCP-99413
P-2042
S-2041
X-2041
C-2045
C-2049
C-2043
C-2042
C-2041
P-2021 P-2031 P-2041
TYP
EM115
(TYP)
X-2051
X-2052
X-2053
X-2054
X-2101
S-2431 X-2100
L-2431
TYP
EM001
(TYP)
S-2430
S-2429 PIT-99432
C
01E01 1/2" = 1'-0"
8660F1099E0102
DISC-99414
LCP-99414
TYP
EM105
(TYP)
CON
TINU
ED ON
D
W
G 99E02
CON
TINU
ED ON
D
W
G 99E04
4 4 4 4
WITH MAXIMUM 2' OF TYPE LIQUID-TYPE FLEXIBLE CONDUIT.

1. FINAL CONDUIT CONNECTION TO PUMP MOTOR SHALL BE MADE #
ENTERING TO THE PUMP TERMINATION BOX.

4. COMBINE POWER AND CONTROL CONDUITS INTO ONE CONDUIT

3. TO PUMP STATION LIGHTING FIXTURES AND RECEPTACLES.

LOCATION.

2. CONDUITS SHALL REMAIN ENCLOSED IN DUCT BANK TO STUB UP ASSOCIATED JUNCTION BOXES, ON THE SAME EQUIPMENT STAND.

1. MOUNT ELECTRICAL DISCONNECT, LOCAL CONTROL PANEL, AND GENERAL NOTES:

KEY NOTES:
130
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:29:54-07'00'
200

Page 369 of 1800 ends

HH-4

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
J
J
J
J
P
lotD
ate: 05
-APR
-2023
2:09:33
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E04
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLU

ELECTRICAL
8660F10 8660F1099E04.dgn

RECYCLED WATER STORAGE POWER AND CONTROL
SV1-99402
SV2-99402
DWG 99E03

CONTINUED ON
JGB
TYP
EM001
(TYP)
TYP
(TYP)
EM020
TYP
EM202
S-3100 2
C-3100 2
TYP
EM015
ANT2-99400
TYP
EM902
4 F
02E01
5 TYP
EM201
L-3101
X-3100
X-3101
S-3101
C-3102
N-3100
L-3200
S-3200
C-3005
C-3001
C-3003
# KEY NOTES:
5 FIT-99406
C-3002
ZSOC-99402
X-3102
X-3103
TYP
EM315
D
02E01
D
01E01 1/8" = 1'-0"
8660F1099E0104
E
02E01 L-3100
avates
1 LIT-99405
LSHH-99403
LSLL-99403
6 3 DESIC-99405
TERMINATE LEVEL INSTRUMENT CABLES ON IT.

PROVIDE TERMINAL STRIP INSIDE THE JUNCTION BOX AND

6. MOUNT JUNCTION BOX ON THE ROOF NEAR LEVEL INSTRUMENTS. 10E14.

5. LIGHTING AND RECEPTACLE CONDUIT CONTINUES ON DRAWING LUGS.

4. SUPPORT ANTENNA MAST POLE ON TANK EMBEDDED SUPPORT
PROVIDE SST SUN SHADE FOR THE BOX.

3. DESICCANT JUNCTION BOX MINIMUM SIZE SHALL BE 6" x 6" x 6".

EMBEDDED SUPPORT LUGS.

2. SUPPORT CONDUITS WITH PREFORMED CHANNEL ON TANK

1. INSTALL CONDUIT SLEEVE FOR LEVEL INSTRUMENT CABLES.
131
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:36:18-07'00'
200

Page 370 of 1800 ends

#4/0 SDBC
#8 SDBC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E12
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

RECYCLED WATER ELECTRICAL BUILDING

LIGHTING, GROUNDING AND RECEPTACLES PLAN
8660F10 8660F1099E12.dgn
R
W PS
-2
R
W PS
-3
G
FCI-W
P
RWPS-3

GFCI-WP
RWPS-2
RWPS-2
RWPS-3

GFCI-WP

TYP (TYP)
EG002
TYP
EG304
TYP
(TYP)
EG205
TYP
(TYP)
EG102
TYP
(TYP)
EM725
TYP
(TYP)
EG511
TYP
EG205
TYP
(TYP)
EG101
TYP
(TYP)
EG001
3 4
1 3
6 5
1 TYP
EL200
TYP
EA030
(TYP)
2 2
6 4
B
9'-0"
a RWPS-1
B
9'-0"
a RWPS-1
B
9'-0"
a RWPS-1
C
9'-0"
RWPS-1
RWPS-1
D
10'-0"
C
9'-0"
RWPS-1
RWPS-1
D
10'-0"
#
GENERAL NOTES:

KEY NOTES:

VFD-99414 VFD-99413
RAD2-99400
PCM-99400 PNL-RWPS-L XFMR-RWPS-L
SWBD-RWPS VFD-99412 VFD-99411
CONTINUED ON DWG 01E01
CON
TINU
ED ON
D
W
G 99E13
CU-99422
CU-99421
INCHES.

SPECIFICATIONS. CONDUITS SHALL NOT BE SMALLER THAN 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

5. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
CONDUCTORS IN THE SAME RACEWAY AND FOR VOLTAGE DROP.

AND SHALL BE DE RATED TO ACCOUNT FOR MULTIPLE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,

4. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE

3. LIGHTING PANEL PNL-RWPS-L IS ABBREVIATED AS RWPS.

AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN. 7 ELECTRICAL
E
01E01 3/4" = 1'-0"
8660F1099E0201
a
RWPS-1
3, D
a
R
W PS
-1
3, D

7. TYPICAL FOR HVAC CONDENSER UNIT.

FIXTURE.

6. PROVIDE EMERGENCY BACKUP LIGHTING PACKAGE FOR THIS

5. SPACE IS RESERVED FOR FUTURE RECYCLED PUMP VFD.

4. CONTINUED ON SHEET 10E13.

CONDUCTOR ACCORDING TO DETAIL EG101/TYP.

3. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING

2. BOND HVAC EQUIPMENT TO THE GROUND RING CONDUCTOR.

CONDUIT AT EXPOSED LOCATIONS.

CONDUCTOR INSIDE MINIMUM SIZE 1-1/2" SCHEDULE 80 PVC
WITH COMPRESSION CONNECTION. INSTALL GROUNDING

1. BOND CEILING METALLIC BEAM TO THE GROUND RING CONDUCTOR C
02E01
A
02E01
avates
132
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:36:44-07'00'
200

Page 371 of 1800 ends

#4/0 SDBC
#6 SDBC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023
2:04:51
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL

RECYCLED WATER PUMP STATION

LIGHTING, GROUNDING, AND RECEPTACLES PLAN
8660F10 8660F1099E13.dgn
99E13
PMP-99411 PMP-99412 PMP-99413 PMP-99414
RWPS-5

GFCI-WP
RWPS-5

GFCI-WP
RWPS-5

GFCI-WP
RWPS-5

GFCI-WP
A
12'-0"
RWPS-4
A
12'-0"
RWPS-4
A
12'-0"
RWPS-4
A
12'-0"
RWPS-4
2 2
1 3
TYP S
EL507
TYP
EG101
(TYP)
TYP
EG002
(TYP)
#
GENERAL NOTES:

KEY NOTES:

5. LIGHTING PANEL PNL-RWPS-L IS ABBREVIATED AS RWPS.

INCHES.

SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 0.75

ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE

4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.

SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE

SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND

3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.

TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER

2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.

GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND

USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A

1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN.

TYP
NF136
4 4. TYPICAL FOR ALL RECYCLED WATER PUMP MOTOR.

3. FOR FUTURE PUMP INSTALLATION.

2. CONTINUED ON SHEET 10E12.

PUMP MOTORS.

INSTALLATION MANUAL. THIS IS TYPICAL FOR ALL RECYCLED WATER

1. BOND MOTOR FRAME ACCORDING TO NEC AND MANUFACTURER
TYP
EL502
F
01E01 3/8" = 1'-0"
8660F1099E0202
D
W
G 99E14
CON
TINU
ED ON
D
W
G 98E12
CON
TINU
ED ON
D
02E01
C
02E01
133
avates
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:39:38-07'00'
200

Page 372 of 1800 ends

HH-4

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
P
lotD
ate: 05
-APR
-2023
2:02:26
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
99E14
LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

HQR
PLK
JGB

ELECTRICAL

RECYCLED WATER STORAGE

LIGHTING, GROUNDING, AND RECEPTACLES PLAN
8660F10 8660F1099E14.dgn
RWPS-5

GFCI-WP
2 2
1 A
RWPS-11
15'-0"
A
RWPS-11
14'-0"
TYP
(TYP)
EL506
TYP
(TYP)
EG002
ANT2-99400
# KEY NOTES:

TYP
(TYP)
EG101
TYP
NF136
D
02E01
E
02E01
F
02E01
G
01E01 1/8" = 1'-0"
8660F1099E0204
DWG 99E13

CONTINUED ON
10E04.

2. LIGHTING AND RECEPTACLE CONDUIT CONTINUES ON DRAWING CONDUCTOR ACCORDING TO DETAIL EG101/TYP.

1. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
avates
TYP
EL506
134
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:21:22-07'00'
200

Page 373 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
SYMBOL DRAWING VISIBLE FIELDS FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5 FIELD - 6 FIELD - 7 FIELD - 8 INSTRUMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTING PRIMARY ELEMENT 2 -LOOP NUMBER BUILDING NO. F -FUTURE
3 -FUNCTION ROOM NO.
4 -FURNISHED BY
5 -LOCATION
6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING OUT -OUTDOOR CONTROL ELEMENT 2 -LOOP NUMBER INT -INTEGRAL F -FUTURE
PRIMARY FUNCTION 3 -FUNCTION REM -REMOTE
OPERATOR 4 -FURNISHED BY
ACCESSIBLE 5 -DESCRIPTION
6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING CONTROL ELEMENT 2 -LOOP NUMBER F -FUTURE
AUXILIARY FUNCTION 3 -FUNCTION
OPERATOR 4 -FURNISHED BY
ACCESSIBLE 5 -LOCATION
6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING CONTROL ELEMENT 2 -LOOP NUMBER F -FUTURE
PRIMARY FUNCTION 3 -FUNCTION
OPERATOR 4 -FURNISHED BY
INACCESSIBLE 5 -LOCATION XR -PROTECTION
6 -EXISTING/FUTURE RELAY

CR -CONTROL
RELAY

XR -INTERPOSING
RELAY
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING CONTROL ELEMENT 2 -LOOP NUMBER F -FUTURE
AUXILIARY FUNCTION 3 -FUNCTION
OPERATOR 4 -FURNISHED BY
INACCESSIBLE 5 -LOCATION XR -PROTECTION
6 -EXISTING/FUTURE RELAY

CR -CONTROL
RELAY

XR -INTERPOSING
RELAY
FIELD EQUIPMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTING NON-POWERED 2 -LOOP NUMBER BUILDING NO. F -FUTURE
3 -FUNCTION/SIZE ROOM NO.
4 -FURNISHED BY
5 -LOCATION
6 -EXISTING/FUTURE
FIELD EQUIPMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTING PRIMARY FUNCTION 2 -LOOP NUMBER BUILDING NO. F -FUTURE
POWERED 3 -FUNCTION ROOM NO.
4 -FURNISHED BY
5 -LOCATION
6 -EXISTING/FUTURE
FIELD EQUIPMENT 1 -TAG MWH-MOTOR REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING AUXILIARY FUNCTION 2 -LOOP NUMBER WINDING F -FUTURE
POWERED 3 -FUNCTION HEATER
4 -FURNISHED BY TSH -TEMPERATURE
5 -LOCATION SWITCH
6 -EXISTING/FUTURE XSH -TORQUE
SWITCH
FIELD EQUIPMENT 1 -TAG MS -MOTOR REFER FVNR -FULL VOLTAGE 120VAC -1P LCP -LOCAL CONTROL E -EXISTING STARTER/DRIVE 2 -LOOP NUMBER STARTER NON-REVERSING STARTER 208VAC -2P PANEL NO. F -FUTURE CUBICLE/CABINET 3 -TYPE RVAT-REDUCED FVR -FULL VOLTAGE 208VAC -3P MCC -MOTOR CONTROL 4 -VOLTAGE-POLE VOLTAGE AUTO REVERSING STARTER 240VAC -2P CENTER NO. 5 -POWER SOURCE TRANSFORMER PWS -PART-WINDING STARTER 240VAC -3P PCM -PROCESS CONTROL 6 -EXISTING/FUTURE STARTER RVAT -REDUCED VOLTAGE AUTO 480VAC -3P MODULE NO.

RVSS-REDUCED RVSS -REDUCED VOLTAGE 2400VAC -3P VCP -VENDOR CONTROL VOLTAGE SOLID STATE STARTER 4160VAC -3P PANEL NO.

SOLID STATE TS1W -TWO SPEED SINGLE

STARTER WINDING
VFD -VARIABLE TS2W -TWO SPEED TWO WINDINGS

FREQUENCY VFD -VARIABLE FREQUENCY

DRIVE DRIVE

INSTRUMENT BUBBLE LOCATIONS NOTES
PC
S

INSTRUMENT TAG IDENTIFICATION LETTERS TABLE

OPERATOR PILOT DEVICE LEGEND
I/O

EQUIPMENT TAGGING TABLE

I/O TYPE DESIGNATIONS
O
PER
ATO
R
INTER
FAC
E/
CON
TR
O
L
D
EV
IC
E
S

INSTRUMENT TYPE DESIGNATIONS TABLE
FURNISHED BY: FBO FURNISHED BY OWNER

FBV FURNISHED BY VENDOR
P
O
W
ER
SOURC
E
PROVIDED BY: PBO PROVIDED BY OWNER

PBV PROVIDED BY VENDOR
FIELD
SYMBOL DRAWING VISIBLE FIELDS FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5 FIELD - 6 FIELD - 7 FIELD - 8 HMI/SCADA SYSTEM 1 -TAG REFER REFER ACTION DESCRIPTION DESCRIPTION E -EXISTING OPERATOR 2 -LOOP NUMBER ALARM F -FUTURE
INTERFACE 3 -FUNCTION SP -NUMERIC
TERMINAL 4 -DESCRIPTION STATUS -SET POINT
5 -DESCRIPTION TREND
6 -EXISTING/FUTURE
HARDWIRED I/O 1 -TAG REFER REFER AI -ANALOG INPUT DESCRIPTION PAC -PROGRAMMABLE E -EXISTING POINT 2 -LOOP NUMBER AO -ANALOG OUTPUT AUTOMATION F -FUTURE 3 -FUNCTION DI -DISCRETE INPUT CONTROLLER NO.
4 -DESCRIPTION DO -DISCRETE OUTPUT PLC -PROGRAMMABLE
5 -LOCATION RTD -RTD INPUT LOGIC
6 -EXISTING/FUTURE CONTROLLER NO.
7 -IO TABLE RIO -REMOTE I/O

VCP -VENDOR CONTROL
PANEL NO.

NETWORK / SOFT I/O 1 -TAG REFER REFER COMMUNICATION PROTOCOL DESCRIPTION PAC -PROGRAMMABLE E -EXISTING 2 -LOOP NUMBER CNET -CONTROLNET AUTOMATION F -FUTURE
3 -PROTOCOL DNET -DEVICENET CONTROLLER NO.
4 -PANEL EIP -ETHERNET/IP PLC -PROGRAMMABLE
5 -PLC FF -FOUNDATION FIELDBUS LOGIC
6 -EXISTING/FUTURE HART-I -HART OVER ETHERNET CONTROLLER NO. 7 -IO TABLE MANF -MFR. PROPRIETARY RIO -REMOTE I/O
8 -SWITCH/SEGMENT MBRTU -MODBUS RTU VCP -VENDOR CONTROL MB+ -MODBUS PLUS PANEL NO.

MBTCP -MODBUS TCP

DP -PROFIBUS DP

PA -PROFIBUS PA

PNET -PROFINET
SNMP -SNMPv3

HTTP -WEB SERVER (TCP/IP)
LOCAL 1 -TAG REFER REFER ACTION DESCRIPTION LOI -LOCAL OPERATOR E -EXISTING OPERATOR 2 -LOOP NUMBER ALARM INTERFACE NO. F -FUTURE
INTERFACE 3 -FUNCTION SP -NUMERIC LCP -LOCAL CONTROL
4 -DESCRIPTION STATUS -SET POINT PANEL NO.
5 -LOCATION TREND PCM -PROCESS CONTROL
6 -EXISTING/FUTURE MODULE NO.

VCP -VENDOR CONTROL
PANEL NO.

PILOT DEVICE 1 -TAG REFER REFER AM -AUTO/MANUAL DESCRIPTION LCP -LOCAL CONTROL E -EXISTING OPERATOR 2 -LOOP NUMBER BYPASS -BY PASS PANEL NO. F -FUTURE INTERFACE 3 -FUNCTION E-STOP -EMERGENCY STOP MCC -MOTOR CONTROL 4 -DESCRIPTION FRLR -FIXED RATE/LEVEL RATE CENTER NO.
5 -LOCATION HOA -HAND/OFF/AUTO PCM -PROCESS CONTROL
6 -EXISTING/FUTURE LOR -LOCAL/OFF/REMOTE MODULE NO.

LOS -LOCK OUT STOP RVS -REDUCED VOLTAGE
LS -LEAD/STANDBY SOLID STARTER NO.

LSR -LOCAL/STOP/REMOTE VCP -VENDOR CONTROL
NOOT -NO OFFLINE/OFFLINE PANEL NO.

TRANSITION VFD -VARIABLE

OC -OPEN/CLOSE FREQUENCY
OLOL -ON LINE/OFFLINE DRIVE NO.

OO -OFF/ON

OSC -OPEN/STOP/CLOSE

RST -RESET

SAAM -SEMI AUTO/AUTO/MANUAL

SEL -SELECT

SPD -SPEED

SS -START/STOP

ST -STOP
POWER DEVICE 1 -TAG CB -CIRCUIT REFER TM -THERMAL MAGNETIC 24VDC -1P DP -DISTRIBUTION E -EXISTING PRIMARY FUNCTION 2 -LOOP NUMBER BREAKER CIRCUIT BREAKER 24VDC -2P PANEL NO. F -FUTURE OPERATOR 3 -FUNCTION DISC -DISCONNECT 24VAC -1P LCP -LOCAL CONTROL ACCESSIBLE 4 -VOLTAGE-POLE FU -FUSE 48VDC -2P PANEL NO. 5 -LOCATION 120VAC -1P LP -LIGHTING PANEL NO.
6 -EXISTING/FUTURE 208VAC -2P MCC -MOTOR CONTROL
208VAC -3P CENTER NO.
240VAC -2P PCM -PROCESS CONTROL
240VAC -3P MODULE NO.
480VAC -3P PP -POWER PANEL NO.
2400VAC -3P VCP -VENDOR CONTROL
4160VAC -3P PANEL NO.

POWER DEVICE 1 -TAG DISC -DISCONNECT REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING AUXILIARY FUNCTION 2 -LOOP NUMBER F -FUTURE
OPERATOR 3 -DESCRIPTION
ACCESSIBLE 4 -DESCRIPTION
5 -DESCRIPTION
6 -EXISTING/FUTURE
POWER DEVICE 1 -TAG CB -CIRCUIT REFER MCP -MOTOR CIRCUIT 24VDC -1P DP -DISTRIBUTION E -EXISTING PRIMARY FUNCTION 2 -LOOP NUMBER BREAKER PROTECTOR 24VDC -2P PANEL NO. F -FUTURE OPERATOR 3 -FUNCTION FU -FUSE SS -SOLID STATE 24VAC -1P LCP -LOCAL CONTROL INACCESSIBLE 4 -VOLTAGE-POLE CIRCUIT BREAKER 48VDC -2P PANEL NO. 5 -LOCATION TM -THERMAL MAGNETIC 120VAC -1P LP -LIGHTING PANEL NO. 6 -EXISTING/FUTURE CIRCUIT BREAKER 208VAC -2P MCC -MOTOR CONTROL 208VAC -3P CENTER NO.
240VAC -2P PCM -PROCESS CONTROL
240VAC -3P MODULE NO.
480VAC -3P PP -POWER PANEL NO.
2400VAC -3P VCP -VENDOR CONTROL
4160VAC -3P PANEL NO.
1 2
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
5 6
1 2
3 4
8 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 1
2 3
4 5
6 7
3 1 2 3 2 5
1 2 3
1 2 3
1 2 3 2 5
3 3
3 4
1 3 5 6 7
1 1
1 3
1 3
3 3
3 3
3 3
3 3
3 3
5 6 7
6 7
6 7
6 7
6 7
6 7
6 7
1-2
3 4
5 6

1 2
3 4
5 6
7 1
2 3
4 8
5 6
7 P
lotD
ate: 06-APR
-2023
7:18:58
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN01
SYMBOLS AND ABBREVIATIONS 1
8660F1000GN01.dwg
lbordelon
8660F10
135
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:18:19-06'00'
200

Page 374 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

TO PROCESS

INSTRUMENT OR CONNECTION
(GUIDED)

ELECTROMAGNETIC OR SONIC SIGNAL
(NOT GUIDED)

ELECTROMAGNETIC OR SONIC SIGNAL
(SOFTWARE OR DATA LINK)

INTERNAL SYSTEM LINK

PNEUMATIC SIGNAL

ELECTRIC SIGNAL

HYDRAULIC SIGNAL

CAPILLARY TUBE

IN PIPE

PRIMARY PROCESS FLOW

IN PIPE

SECONDARY PROCESS FLOW

IN CHANNEL

PRIMARY PROCESS FLOW

IN CHANNEL

SECONDARY PROCESS FLOW

EQUIPMENT ENCLOSURE

EXISTING

DESIGNATIONS

MISCELLANEOUS P&ID SYMBOLS

PIPE CALLOUT

PROCESS CONTINUATION

INSTRUMENT TAG IDENTIFICATION LETTERS P&ID LINE SYMBOLS

PROCESS LINE SYMBOLS
FUTURE

SIGNAL CONTINUATION
TYP
*

SCHEMATIC DETAIL

TYPICAL DETAIL
FUTURE

CONTINUATION
SHEET
UNIQUE

IDENTIFIER

CONTINUATION
SHEET
UNIQUE

IDENTIFIER

I/O TYPE DESIGNATIONS INSTRUMENT TYPE DESIGNATIONS SPECIFIC ABBREVIATIONS AUX1 RUNNING MSL MOTOR START LOW CGD COMBUSTIBLE GAS DETECTOR RTD RESISTANCE TEMP DETECTOR HTR HEATER AUX2 FAILED/FAULT MSM VALVE MODULATE COND CONDUCTIVITY SB SLUDGE BLANKET HTU HEAT TRACE UNIT AUXF1 RUNNING FORWARD MSP MOTOR STOP DO DISSOLVED OXYGEN SC STREAMING CURRENT MWH MOTOR WINDING HEATER AUXH1 RUNNING HIGH MSR MOTOR START REVERSE FMCW FREQ. MODULATED CONT. WAVE SD SLUDGE DEPTH SV SOLENOID VALVE AUXL1 RUNNING LOW MST MOTOR START IS INTRINSIC SAFETY BARRIER SH SODIUM HYPOCHLORITE SPD SURGE PROTECTIVE DEVICE AUXR1 RUNNING REVERSE SS SPEED SIGNAL LEL LOWER EXPLOSIVE LIMIT SO2 SULFUR DIOXIDE UPS UNINTERRUPTIBLE POWER SUPPLY

SVC SOLENOID VALVE CLOSE ZC POSITION COMMAND MLSS MIXED LIQUOR SUSPENDED SOLIDS TDR TIME DOMAIN REFLECTOMETRY YA STATUS AUTO

SVO SOLENOID VALVE OPEN ZCC POSITION COMMAND CLOSE ORP OXIDATION REDUCTION POTENTIAL TOC TOTAL ORGANIC CARBON YR STATUS REMOTE MS RUN ZCO POSITION COMMAND OPEN P-SUB PRESSURE SUBMERSIBLE TSS TOTAL SUSPENDED SOLIDS Y1 STATE RUNNING MSF MOTOR START FORWARD PC PARTICLE COUNTER UVI UV INTENSITY Y2 ALARM FAILED/FAULT

MSH MOTOR START HIGH PTOF PULSE TIME OF FLIGHT UVT UV TRANSMITTANCE

OPERATOR PILOT DEVICE LEGEND

PILOT DEVICE FUNCTION

DEVICE TYPE
LO
C

AL-OFF-R
EM
OTE
(LO
R
)O
R
LO
C
AL-S
TO
P
-R
EM
OTE
(LS
R
)
S
TO
P
(SP
)
S
TAR
T
(S
T)
HAND
-OFF-AU
TO
(HOA
)
OFF-ON
(OO
)
SELEC
T
(SEL)
O
PEN
-S
TO
P
-C
LO
S
E
(O
S
C
)
JOG
O
PEN
-HO
LD
-C
LO
S
E
(JOH
C
)
S
EM
IAU
TO
-AU
TO
-MANUAL
(SAAM
)
LEAD
-LAG
-S
TAND
B
Y
(LLG
S
)
JOG
O
PEN
-JOG
C
LO
S
E
(JO
JC
)
ON
LIN
E
-OFFLIN
E
(O
LO
F)
AU
TO
-MANUAL
(AM
)
FIXED
R
ATE
-LEVEL
R
ATE
(FR
LR
)
O
PEN
-C
LO
S
E
(O
C
)
NO
OFFLIN
E
-OFFLIN
E
TRAN
S
ITION
(NOO
T)
LO
W
-H
IGH
(LH
)
R
E
SET
(R
S
T)
SPEED
(SPD
)
S
TAR
T
-S
TO
P
(S
TSP
)
E
-S
TO
P
(E
-SP
)
B
YPASS
(B
YP
)
S
ILEN
C
E
P
O
S
ITION
(P
O
S
)
PILOT DEVICE TAG (HAND SWITCHES) HSA* HSB HSC HSD* HSE HSF HSG HSH HIS HSJ* HSK HSL* HSM* HSN HSO HSP HSQ* HSR HSS HST* HSU HSV HSW HSX HSY HSZ PLC I/O TAG: * = R (REMOTE), A (AUTO), ETC.

INSTRUMENT FUNCTION

MEASURED VARIABLE
ELEM
EN
T
TRAN
S
M
ITTER
IND
IC
ATING
TRAN
S
M
ITTER

CONVERTER
TRAN
SDU
C
ER,

RELAY SPEC
IAL
D
EV
IC
E
S
IND
IC
ATO
R
R
EC
O
R
D
ER
CON
TR
OLLER
IND
IC
ATING
CON
TR
OLLER
R
EC
O
R
D
ING
CON
TR
OLLER
S
W
ITC
H
S
W
ITC
H
LO
W
LO
W
S
W
ITC
H
LO
W
S
W
ITC
H
H
IGH
S
W
ITC
H
H
IGH
H
IGH
S
W
ITC
H
C
O
M
B

INATION
H
IGH
LO
W
AC
TION
ALAR
M
LO
W
LO
W
ALAR
M
LO
W
ALAR
M
H
IGH
ALAR
M
H
IGH
H
IGH
TO
TALIZE
IND
IC
ATO
R
TRAN
S
M
ITTER
VALVE
GAUG
E
LIGH
T
SPEED

SETTING

A ANALYSIS AE AT AIT AY AI AR AC AIC ARC AS ASLL ASL ASH ASHH ASHL AALL AAL AAH AAHH AL

B BURNER FLAME BE BT BIT BY BI BR BC BIC BRC BS BSLL BSL BSH BSHH BALL BAL BAH BAHH BL

C CONDUCTIVITY CE CT CIT CY CI CR CC CIC CRC CS CSLL CSL CSH CSHH CSHL CALL CAL CAH CAHH CL

D DENSITY DE DT DIT DY DI DR DC DIC DRC DS DSLL DSL DSH DSHH DSHL DALL DAL DAH DAHH DL

E VOLTAGE ESL

F FLOW FE FT FIT FY FI FR FC FIC FRC FS FSLL FSL FSH FSHH FSHL FALL FAL FAH FAHH FQI FCV FG FL

FF FLOW RATIO FFY FFI FFC FFIC FFS FFL
H HAND (MANUAL)* HC HS* HA* HV HL HSS
I CURRENT IT IIT lY II IR IC llC IRC IS ISLL ISL ISH ISHH IALL IAL IAH IAHH lL

J POWER

K TIME KY KI KR KC KIC KRC KS KSLL KSL KSH KSHH KALL KAL KAH KAHH KV KL

L LEVEL LE LT LIT LY LI LR LC LIC LRC LS LSLL LSL LSH LSHH LSHL LALL LAL LAH LAHH LCV LG LL

M MOISTURE OR HUMIDITY ME MT MIT MY MI MR MC MIC MRC MS MSLL MSL MSH MSHH MALL MAL MAH MAHH ML

N USER'S CHOICE

P PRESSURE OR VACUUM PE PT PIT PY PI PR PC PIC PRC PS PSLL PSL PSH PSHH PSHL PALL PAL PAH PAHH PCV PL

PD DIFFERENTIAL PRESSURE PDT PDIT PDY PDI PDR PDC PDIC PDRC PDS PDSLL PDSL PDSH PDSHH PDALL PDAL PDAH PDAHH PDCV PDL

Q QUANTITY QE QT QIT QY QI QR QS QSLL QSL QSH QSHH QALL QAL QAH QAHH

R RADIATION

S SPEED SE ST SIT SY SI SR SC SIC SRC SS SSLL SSL SSH SSHH SALL SAL SAH SAHH

T TEMPERATURE TE TT TIT TY TI TR TC TIC TRC TS TSLL TSL TSH TSHH TSHL TALL TAL TAH TAHH TCV TL

TD DIFFERENTIAL TEMPERATURE TDT TDIT TDY TDI TDR TDC TDIC TDRC TDS TDSLL TDSL TDSH TDSHH TDALL TDAL TDAH TDAHH TDCV TDL

U MULTIVARIABLE UI UR UC UIC URC US UL

V VISCOSITY VE VT VIT VY VI VR VC VIC VRC VS VSLL VSL VSH VSHH VALL VAL VAH VAHH VL

W WEIGHT WE WT WIT WY WI WR WS WSLL WSL WSH WSHH WALL WAL WAH WAHH

X UNCLASSIFIED XE XT XIT XY XI XR XC XIC XRC XS XSLL XSL XSH XSHH XALL XAL XAH XAHH XCV XG XL

XV VIBRATION XVE XVT XVY XVI XVR XVS XVSH XVSHH XVAH XVAHH XVL Y STATUS*** YI YL
Z POSITION ZE ZT ZIT ZY ZI ZS** ZV ZL**
* REFER TO OPERATOR PILOT DEVICE LEGEND
** LETTER INDICATES POSITION (O=OPEN, C=CLOSED, R=RAISE, L=LOWER, ETC)

PIPE SIZE
TYPNUM
TYPNUM2
TYPNUM3
TYPNUM4
TYPNUM5
TYPNUM6
?
-
# DWG NO.

DESC1_
DESC2_
# DWG NO.

DESC1_
DESC2_
P
lotD
ate: 06-APR
-2023
7:19:14
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN02
SYMBOLS AND ABBREVIATIONS 2
8660F1000GN02.dwg
lbordelon
8660F10
136
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:18:43-06'00'
200

Page 375 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

ACTUATORS
O
C
BALL

DOUBLE FLAP

FLAPPER
SWING

CHECK VALVES PRESSURE VALVES

REGULATING

PRESSURE RELIEF

VACUUM RELIEF
S
VALVES

AIR-RELIEF
ANGLE
BALL

BUTTERFLY
CONE

DIAPHRAGM
3-WAY PLUG
4-WAY
3-WAY

BALL V-NOTCH
GATE
GLOBE
HOSE
MUD
NEEDLE
PINCH

PLUG ECCENTRIC

PLUG CONCENTRIC

TELESCOPING

PUMP DISCHARGE
S
P
S
P
S

DIAPHRAGM

PNEUMATIC
HAND

HYDRAULIC
S
S
S
S
S
P
S
P
~
IY
I/P
PIPING

AIR GAP

BLIND FLANGE
DRAIN
PUMPS

AIR DRIVEN

CENTRIFUGAL

DIAPHRAGM
GEAR
PISTON

SUBMERSIBLE

WATER CHAMP
FAN

BASKET STRAINER

COALESCER

EDUCTOR/EJECTOR

VAPORIZER

BLOW-OFF SILENCER

INLINE DUCT DAMPER

GAS CANNON

GRINDER

HEAT EXCHANGER

HORIZONTAL MIXER
FILTER

FILTER SEPARATOR

FLAME ARRESTER

EYEWASH

FINE FILTER

FLOW CONDITIONER

HOSE CONNECTION

INLET STRAINER
MIXER
MOTOR
NOZZLE

RUPTURE DISK

SAMPLE PORT

SIGHT TUBE

VAPOR HEATER
OR
MISC

VALVE DESIGNATIONS

NO NORMALLY OPEN

NC NORMALLY CLOSED

FO FAIL OPEN

FC FAIL CLOSE

FLP FAIL LAST POSITION

SMOKE DETECTOR

FIRE ALARM/SENSOR
HOIST

EXHAUST FAN

SOLENOID

DISCRETE

ELECTRIC

MODULATING

ELECTRIC

HYDRAULIC

ELECTRIC

MODULATING

HYDRAULIC

OPEN/CLOSE

SINGLE SOLENOID

PNEUMATIC
w/ SPEED CONTROL

SINGLE SOLENOID

PNEUMATIC

OPEN/CLOSE

DUAL SOLENOID

PNEUMATIC

OPEN/HOLD/CLOSE

DUAL SOLENOID

PNEUMATIC
w/ SPEED CONTROL

OPEN/CLOSE

DUAL SOLENOID

PNEUMATIC

MODULATING

PNEUMATIC
w/ SPEED CONTROL

OPEN/CLOSE

MODULATING

PNEUMATIC

PLUGGED

CAPPED OR

INCREASER

CONCENTRIC

REDUCER

CONCENTRIC

INCREASER

ECCENTRIC

REDUCER

ECCENTRIC

COUPLING

EXPANSION
CENTER

VIBRATION

EXPANSION JOINT

CONNECTION

FLEXIBLE

DISCONNECT
QUICK

OR HOSE

PERISTALTIC
CAVITY

PROGRESSIVE

TURBINE

VERTICAL

CHOPPER

VERTICAL
BLOWER

SINGLE STAGE

CENTRIFUGAL
BLOWER

MULTI STAGE

CENTRIFUGAL

COMPRESSOR

RECIPROCATING

COMPRESSOR
SCREW

COMPRESSOR

LIQUID RING
BLOWER

ROTARY LOBE
DRYER

DESICCANT
COLUMN

CALIBRATION
-BURIED VALVE BOX

PLUG CONCENTRIC

LUBRICATED

PLUG CONCENTRIC
BOX

BURIED VALVE

LUBRICATED

PLUG CONCENTRIC
w-VALVE BOX

PLUG ECCENTRIC

LUBRICATED

PLUG ECCENTRIC

VALVE BOX

LUBRICATED BURIED

PLUG ECCENTRIC

BURIED VALVE BOX
BUTTERFLYPRESSURE TAP

EXTERNAL

REDUCING

PRESSURE

SELF CONTAINED

REDUCING

PRESSURE

EXTERNAL TAP

REGULATING

BACKPRESSURE

SELF CONTAINED

REGULATING

BACKPRESSURE
SWING

SPRING LOADED

GENERAL

SPRING LOADED
CHECK

DIAPHRAGM

INLINE STATIC MIXER

MATERIAL CHANGE

COMPRESSORS

BLOWERS/
VALVE

OPERATED
w/THERMALLY

FLAME ARRESTER

SAMPLER

COMPOSITE

PERISTALTIC

RESTRICTION

ORIFICE

DAMPENER

PULSATION
DRYER

REFRIGERATED

CLEANED

MECHANICALLY

STRAINER -

WITH BLOW OFF

STRAINER

WYE TYPE

STRAINER

ATMOSPHERE

VENT TO
UNION
TEE
P
P
P

DIAPHRAGM

CHEMICAL FEED
OR
VENT

PREVENTER

BACK FLOW

VALVE BOX

GATE-BURIED

DIFFUSER

AIR / CHEMICAL

LOCATOR

EQUIPMENT/INSTRUMENT
E
D
E
M
E
H
H
P
S
M

LOUVER OR DAMPER
FLOAT

CONNECTION

FLANGED
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN03
SYMBOLS AND ABBREVIATIONS 3
8660F1000GN03.dwg
lbordelon
8660F10
137
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:18:56-06'00'
200

Page 376 of 1800 ends

IDENTIFIER
UNIQUE

IDENTIFIER
UNIQUE
SHEET

CONTINUATION
SHEET

CONTINUATION

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

ORIFICE

DISPLACEMENT
POSITIVEVORTEX
V-CONE

THERMAL
BATCH

CORIOLIS

MAGNETIC

PADDLE WHEEL

ROTAMETER

BUBBLER

CAPACITANCE

ELECTRODE
FLOAT

INVERTED COLUMN

RADAR PTOF

RADAR TDR

ULTRASONIC
GAUGE

PRESSURE SWITCH
KNIFE
SLIDE
SLUICE
STOP
SLIDE
SLUICE
STOP
FLAP
WEIR

PARSHALL

LEOPOLD-LAGCO

PALMER-BOWLUS

TRAPEZOIDAL

CUTTHROAT

REGULAR
w/ END CONTRACTIONS

RECTANGULAR

TURBINE
PROPELLEROR FLOW NOZZLE

VENTURI TUBE

PRESSURE

DIFFERENTIAL

SUBMERSIBLE

SUSPENDED/

ANNULAR
SEAL

DIAPHRAGM
SEAL

SANITARY
SEAL

PRESSURE SWITCH

MANOMETER

PRESSURE DIFFERENTIAL PRESSURE PRESSURE SEALS

INDICATOR

DIFFERENTIAL
GAUGE

TRANSMITTER

PRESSURE
SWITCH

PRESSURE

DIFFERENTIAL

TRANSMITTER

PRESSURE

DIFFERENTIAL

TUNING FORK
PISTON
WEIRS

SIDE VIEW PLAN VIEW

FLOW FLUMES LEVEL

SIDE VIEW PLAN VIEW
w/o END CONTRACTIONS

RECTANGULAR
w/o END CONTRACTIONS

RECTANGULAR
w/ END CONTRACTIONS

RECTANGULAR
(TRIANGULAR)

V-NOTCH
(TRIANGULAR)

V-NOTCH
(CIPOLLETTI)

TRAPEZOIDAL
(CIPOLLETTI)

TRAPEZOIDAL

PRESSURE/VACUUM

EXAMPLE
GATES

PITOT TUBE

ANNUBAR

ULTRASONIC
BIOGAS

ULTRASONIC

THERMOMETER

HYDRAULIC

STRAIN GAUGE
w/THERMOWELL

TEMPERATURE
GAUGE

TEMPERATURE
WEIGHT

TEMPERATURE
PROBE

CONTINUOUS WAVE)

MODULATED
(FREQUENCY
RADAR

BUTTERFLY
MM
K
N
A
T
T

NETWORKS

OPTIC CABLE
24-STRAND FIBER

REPRESENTS ONE

FIBER LINE
24/FO-SM

OPTIC CABLES
24-STRAND FIBER

REPRESENTS TWO

FIBER LINE
(2) 24/FO-SM (1) 24/FO-SM EA.

OPTIC CABLE
24-STRAND FIBER

REPRESENTS ONE

EACH FIBER LINE

FIBER ABBREVIATIONS
XX = MODE
FO = FIBER OPTIC
## = STRAND COUNT
##/FO-XX
MM = MULTIMODE
SM = SINGLE MODE
(4)
CABLES

COPPER ETHERNET

REPRESENTS FOUR

COPPER LINE
(2) EA.

CABLES

COPPER ETHERNET

REPRESENTS TWO

EACH COPPER LINE

NETWORK ABBREVIATIONS

VLAN SYMBOLS
= BUSINESS NETWORK
= SECURITY CONTROL NETWORK
= BUILDING MANAGEMENT SYSTEM
= PROCESS CONTROL NETWORK

MISCELLANEOUS NETWORK SYMBOLS

NETWORK CABLE CONTINUATIONS

CONTINUATION

TOP OF PAGE STYLE

FIELD NETWORK DEVICE

NETWORK EQUIPMENT CALLOUT
TAG
DESC 1

CABLE CALLOUTS AND ABBREVIATIONS
FPP
ES
NP
NR
PCN-W
SCN
PLCN
PCN
MIN
FCN
BSN
BMS
= FIBER PATCH PANEL
= ETHERNET SWITCH
= NETWORK PANEL
= NETWORK RACK
= WIRELESS PROCESS CONTROL NETWORK
= SECURITY CONTROL NETWORK
= PLC NETWORK
= PROCESS CONTROL NETWORK
= MAINTENANCE INFORMATION NETWORK
= FIELD CONTROL NETWORK
= BUSINESS NETWORK
= BUILDING MANAGEMENT SYSTEM

COPPER ETHERNET

FIBER OPTIC ETHERNET

WIRELESS ETHERNET

PROFIBUS DP

PROFIBUS PA

NETWORK LINE SYMBOLS

STYLE CONTINUATION

BOTTOM/LEFT OF PAGE
SYMBOL

DEVICE SPECIFIC
= WIRELESS PROCESS CONTROL NETWORK
= MAINTENANCE INFORMATION NETWORK
= PLC NETWORK
= FIELD CONTROL NETWORK

SERIAL DATA
PDIT
PDSL
PSH
PSH
PIT
PE
PE
PDE
PDE
PE
PI PDI
SEGMENT #

P&ID DRAWING REFERENCE
DESC 3
DESC 2
DESC 1
TAG

PROTOCOL

PANEL TAG

PLC TAG
#
DWG NO.

DESC 1
DESC 2
DESC 3
#
DWG NO.

DESC 1
DESC 2
DESC 3
GATE
WASTE
P
lotD
ate: 06-APR
-2023
7:16:13
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
00GN04
SYMBOLS AND ABBREVIATIONS 4
8660F1000GN04.dwg
lbordelon
8660F10
138
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:19:21-06'00'
200

Page 377 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

PROCESS SWITCHES HAND SWITCHES RELAYS TERMINAL BLOCKS I/O MISC

CLOSE ON RISING LEVEL

FLOAT SWITCH

OPEN ON RISING LEVEL

FLOAT SWITCH

CLOSE ON RISING PRESSURE

PRESSURE SWITCH

OPEN ON RISING PRESSURE

PRESSURE SWITCH

CLOSE ON RISING TEMPERATURE

TEMPERATURE SWITCH

OPEN ON RISING TEMPERATURE

TEMPERATURE SWITCH

CLOSE ON INCREASE IN FLOW

FLOW SWITCH

OPEN ON INCREASE IN FLOW

FLOW SWITCH

OPEN ON RISING VIBRATION

VIBRATION SWITCH

CLOSE ON RISING VIBRATION

VIBRATION SWITCH

OPEN ON HIGH TORQUE

TORQUE SWITCH

THREE POSITION SELECTOR SWITCH

TWO POSITION SELECTOR SWITCH

MUSHROOM HEAD PUSHBUTTON

MAINTAINED CONTACT

PUSH-PULL PUSHBUTTON

PULL CORD SWITCH

IN PLC/PCM PANEL

TERMINAL

IN MOTOR CONTROL CENTER

TERMINAL

IN LOCAL STARTER CONTROL PANEL

TERMINAL

AT FIELD DEVICE

TERMINAL

IN FIELD PANEL

TERMINAL

IN (USER CHOICE)

TERMINAL

DIGITAL BUS CONNECTOR
a = INPUT OR OUTPUT AS INDICATED

PLC DISCRETE

DIGITAL BUS

SOLENOID
M = TYPE

METER UNIT
MOTOR

CIRCUIT BREAKER

DISCONNECT
FUSE
* - MOTOR TAG I.D.

MOTOR WINDING HEATER

VARISTOR

CAPACITOR

RESISTOR

BATTERY
DIODE

OVERLOAD CONTACT

DRAWOUT CONNECTION
GROUND

LIGHTNING ARRESTOR
a = INPUT OR OUTPUT AS INDICATED

PLC ANALOG
IN RTU

TERMINAL

STOP-LOCKOUT PUSHBUTTON

SPRING-RETURN

SPACE HEATER

ELAPSED TIME METER

PADLOCK SWITCH

xox
xo
xoo
ANALOG
a

DIGITAL
BUS
a
M
MWH-*
KI-*
ETM
HP
a
b
c
d
H1 H3 H2 H4
X1 X2

xoo

CLOSE ON HIGH TORQUE

TORQUE SWITCH
NCTC
NCTO
NOTC
NOTO

CONTROL CONTACT

NORMALLY CLOSED

CONTROL CONTACT

NORMALLY OPEN

TIMED CLOSING

NORMALLY OPEN

TIME DELAY CONTACT

TIMED OPENING

NORMALLY CLOSED

TIME DELAY CONTACT

TIMED OPENING

NORMALLY OPEN

TIME DELAY CONTACT

TIMED CLOSING

NORMALLY CLOSED

TIME DELAY CONTACT

LIMIT SWITCH

NORMALLY CLOSED

HELD OPEN LIMIT SWITCH

NORMALLY CLOSED

LIMIT SWITCH

NORMALLY OPEN

HELD CLOSED LIMIT SWITCH

NORMALLY OPEN

MOMENTARY PUSHBUTTON

NORMALLY OPEN

MOMENTARY PUSHBUTTON

NORMALLY CLOSED

TRANSFORMER

CONTROL POWER

HEATERS

MOTOR OVERLOAD

PROTECTION

TRANSIENT SURGE

CLOSED IN
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS

CLOSED IN

CLOSED IN

CLOSED IN
d = DESCRIPTION
c = TIMING RANGE/SETTING

TDOFF - TIME DELAY ON DEENERGIZATION
b = TDON - TIME DELAY ON ENERGIZATION

R -MOTOR STARTER COIL - REVERSE

F -MOTOR STARTER COIL - FORWARD

H -MOTOR STARTER COIL - HIGH SPEED

L -MOTOR STARTER COIL - LOW SPEED

M -MOTOR STARTER COIL

TD -TIME DELAY RELAY

CR -CONTROL RELAY
a = TYPE

RELAY COIL
* = E -ETHERNET
* = H2 -FOUNDATION FIELDBUS H2
* = H1 -FOUNDATION FIELDBUS H1
* = DP -PROFIBUS DP
* = PA -PROFIBUS PA
* = D -DEVICENET

INDICATORS
HORN
C = CLEAR
M = MAGENTA
B = BLUE
A = AMBER
W = WHITE
G = GREEN
R = RED
a = LENS COLOR
BEACON
C = CLEAR
Y = YELLOW
B = BLUE
A = AMBER
W = WHITE
G = GREEN
R = RED
a = LENS COLOR
a PILOT LIGHT
a
a
H
*
P
lotD
ate: 06-APR
-2023
7:19:21
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
AAW

INSTRUMENTATION

SCHEMATIC SYMBOLS
8660F10 8660F1000GN05.dgn
BAL
00GN05
139
awills
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:19:49-06'00'
200

Page 378 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

TERMINAL PANEL
PCM-300
PLC
MCC-1201
VFD
REMOTE
REMOTE
STOP
START
REMOTE
AUX1-210

RUNNING
FAIL
AUX2-210

WINDING
MOTOR
MWH-210
HEATER
MOTOR

CONNECTION
J-BOX
J-BOX
MWH
210
PMP
210
TSH
210
PSH
210
PE
210
M
J-BOX

SPEED IN
LOCAL
HSAL-210
LOCAL
MODE
FIT
210
FE
210
FQT
210
OFF

LOCAL REMOTE
xoo
oox

STOP
LOCAL
HSB-210
STOP

HSC-210
LOCAL
START
LCP-210
PMP-210

UTILITY WATER PUMP
MOTOR:

INV. DUTY, TEFC
TOSHIBA MODEL: XYZ
PUMP
200 GPM @ 20 FT TDH
900-1800 RPM
GOULD MODEL: XYZ
MODEL: XYZ
RANGE: 0-200 PSIG
SETPOINT: 50 PSIG

ENDRESS HAUSER
CAT NO.: XYZ
FLOW RANGE: 200-2500 GPM
FLOW TOTAL: 1 PULSE/500 GAL
(PSH210-1/PCM300-CB1300H2)
(PSH210-2/PCM300-C0001)
AQ0001+
AQ0001-
SHLD
FU1300-P1
FU1300-M1
<BLK-1>
<WHT-1>
FU1300-H1
I001
<BLK>
Q001A
<BLK>
Q001B
<RED>
E-STOP
Q002A
<BLU>
C0001
Q002B
CB1-210H
CB1-210N
120VAC
FU1300-P2
FU1300-M2
FU1300-P3
<BLK-1>
<WHT-1>
<BLK-2>
<WHT-2>
C0004
FU1300-H3
I003
<BLU>
I004
FU1300-H4
<ORG>
FU1300-H5
I006
<YEL>
(VFD210-11,12/PCM300-AQ001)
(VFD210-13,14/PCM300-AI001)
(VFD210-15/PCM300-Q001A)
(VFD210-16/PCM300-Q001B)
(VFD210-17/PCM300-Q002A)
(VFD210-18/PCM300-Q002B)
(FIT210-L/PCM300-CB1210H)
(FIT210-N/PCM300-CB1210N)
(FIT210-1,2/PCM300-AI002)
(FQT210-4,5/PCM300-FU1300P3; C0004)
(VFD210-20/PCM300-I003)
(VFD210-22/PCM300-I004)
(LCP210-3/PCM300-FU1300H5)
(LCP210-4/PCM300-I006)
(MWH210-H/VFD210-33)
(MWH210-C/VFD210-X2)
(PMP210-T1/VFD210-T1)
(PMP210-T2/VFD210-T2)
(PMP210-T3/VFD210-T3)
(TSH210-NC/PCM300-CB1300H1)
(TSH210-C/PCM300-I001)
(LCP210-P1/VFD210-1)
(LCP210-P2/VFD210-2)
(LCP210-P3/VFD210-3)
(LCP210-1/VFD210-5)
(LCP210-2/VFD210-6)
(LCP210-5/VFD210-7)
(LCP210-6/VFD210-8)
(LCP210-7/VFD210-9)
(LCP210-8/VFD210-10)
HSS
210
HSA
210
HSB
210
HSC
210
FE/FIT/FQT-210
PE/PSH-210
START

(CB1300-H)
AI001+
SHLD
FU1300-H2
C0002
C0003
(VFD210-24/PCM300-C0003)
(VFD210-23/PCM300-C0002)
(VFD210-19/PCM300-FU13000H3)
(VFD210-21/PCM300-FU1300H4)
SHLD
AI002+
120 VAC
MODEL: XYZ

PHOENIX
GND
SHLD
(C0002)
(C0003)
(C0001)
(CB1300-H6) (I005)
(C0004)
(FU1300-M3)
(CB1300-H7) (I002)
(PSH210-1/PCM300-C001)
(PSH210-1/PCM300-FU1300H2)
(TSH210-NC/PCM300-I001)
(TSH210-NC/PCM300-FU1300H1)
(FU1300-P)
M M
(CB1-300N1)
1 2
3 4
5 6
7 8
210
%AQ001

SPEED OUT
RACK 1
SLOT 2
1 2
210
%AI001

SPEED IN
RACK 1
SLOT 3
TSH
210
%I001

MTR TEMP
RACK 1
SLOT 4
MSP
210
%Q001
STOP
RACK 1
SLOT 5
PSH
210
%I005

HI PRESS
RACK 1
SLOT 4
F
210
%AI002
FLOW
RACK 1
SLOT 2
FQ
210
%I002

FLOW TOT
RACK 1
SLOT 4
AUX1
210
%I003

RUNNING
RACK 1
SLOT 4
AUX2
210
%I004
FAIL
RACK 1
SLOT 4
HSAR
210
%I006
REMOTE
RACK 1
SLOT 4
210
%Q002
START
RACK 1
SLOT 5
8 3
4 11
12 7
5 6
4 3
3 4
10 9
1 2
1 1
2 2
3 1
5 6
2 4
4 2
5 6
1 3
23 24
22 21
19 20
18 17
15 16
14 13
12 11
T3
T1
T2
X2
33 9
10 8
7 6
5 4
2 1
3 CR1
210
CR2
210
120 VAC
MODEL: XYZ

PHOENIX

UTILITY WATER HIGH PRESSURE

UTILITY WATER FLOW METER
120 VAC
24 VDC
CB1-300H
FU1-300P
+
-
FU1-300M
CB1-300N (CB1300-N)
SS-210
SB-210
SS
SB
OUT
SPEED
IN
SPEED
VFD-210
SECTION - 3
CUBICLE - 2
30HP, 480VAC, 42 AMPS
CONSTRUCTION. THE LOOP DIAGRAM SHOWN ABOVE DISPLAYS THE LEVEL OF EXPECTED DETAIL.

DIAGRAMS FOR THE ENTIRE FACILITY. PRELIMINARY DETAILED LOOP DIAGRAMS TO BE SUBMITTED FOR REVIEW PRIOR TO BEGINNING THE ABOVE DRAWING IS INCLUDED AS AN EXAMPLE ONLY AND IS NOT PROJECT SPECIFIC. CONTRACTOR SHALL FURNISH LOOP C-01-002
S-01-001
S-01-003
L-01-001
C-01-001
C-01-003
P-01-001 P-01-002
S-01-002
P1
P2
P3

MSP-210
MS-210 MS
H
C
C
1 2
L
N
G
1 2
4 5
T1
T2
T3
NC
P
lotD
ate: 06-APR
-2023
7:19:29
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
AAW

INSTRUMENTATION

SAMPLE LOOP DRAWING
8660F10 8660F1000GN06.dgn
BAL
00GN06
140
awills
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:20:14-06'00'
200

Page 379 of 1800 ends

1/4"
6 1/4"
2"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
XXX AMPS, XXX VOLTS, 1Ø
CP-99400
PLC-99400
XXX AMPS, XXX VOLTS, 1Ø
CP-99400
PLC-99400
11 0
31 0
90 70 50
30°F
Pfannenberg
2 1
N L

TEST MONTHLY

SEE INSTRUCTIONS

RESETRESET
TEST
TEST N
NO
C
COM
/G N L L N /G

QUINT POWER
AC 100-240V
L
Input
N

22.5-28.5V
DC OK
Adjust
OutputDC 24V 5A
13 OK 14 DC

QUINT POWER
AC 100-240V
L
Input
N

22.5-28.5V
DC OK
Adjust
OutputDC 24V 5A
13 OK 14 DC
8 6
LNK
ACT
LNK
ACT
4 2
LNK
ACT
LNK
ACT
7 5
3 1
LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
!

LNK/ACT

LNK/ACT
X
2 F
X
1 F
LNK
GB1 ACT GB2
11 0
31 0
90 70 50
30°F
Pfannenberg
2 1
P
lotD
ate: 06-APR
-2023
7:19:39
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
AAW

INSTRUMENTATION
8660F10 8660F1002N001.dgn
SCALE:

FILE:
1 -

NAMEPLATE DETAIL
6' = 1'-0"
1 -
3 19
13 21
18 17
5 6
4 2
1 7
8 POWER ON
SCALE:

FILE:
2 - 6' = 1'-0"
2 -
22 15
16 15
12 CP-99400 PANEL ELEVATION EXTERIOR
8660F1000N671.2dm
8660F1000N671.2dm
8 8 8 8
8 8
11 20
23 8
PCM-99400 PANEL ELEVATION INTERIOR
25 28
26 GENERAL NOTES:

PCM-99400 ELEVATION LAYOUT
02N01
9 14
CABINET.

7. QUANTITY OF COMPONENTS VARY AS REQUIRED FOR EACH
PENETRATIONS ALLOWED.

BOTTOM OF THE ENCLOSURE. NO SIDE, FRONT, OR REAR

6. ALL CONDUIT PENETRATIONS SHALL BE LOCATED AT THE TOP OR CONTROL CABINETS.

5. NO 480VAC CIRCUITS SHALL TERMINATE IN OR PASS THROUGH SHORT CIRCUIT RATINGS.

4. FOLLOW ALL UL 508 AND 508 SUPPLEMENT 5B TO DETERMINE THE NATIONAL ELECTRIC CODE.

3. CONSTRUCT PANEL TO MEET THE FULL INTENT OF ARTICLE 409 OF

2. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.

NUMBERS.

LAYOUT WITH ALL EQUIPMENT, MANUFACTURERS, AND PART

TO SUPPLY AS-BUILT DRAWINGS SHOWING FINAL ENCLOSURE

1. ENCLOSURE DRAWING REPRESENTS DESIGN INTENT. CONTRACTOR BAL
lbordelon
27 PILOT DEVICES DETAIL

CONTROL PANEL - BILL OF MATERIALS

ITEM DESCRIPTION
1 ENCLOSURE
2 NAMEPLATE
3 DATA POCKET
4 INTRUSION DOOR SWITCH
5 INTERNAL FOLDING SHELF
6 CABINET LIGHT WITH DOOR SWITCH
7 POWER PILOT LIGHT
8 WIRE DUCT (AS REQUIRED)
9 DIN RAIL (AS REQUIRED)
10 NOT USED
11 PLC CHASSIS
12 MANAGED ETHERNET SWITCH
13 ANALOG TERMINAL BLOCKS (AS REQUIRED)
14 RECEPTACLE
15 POWER SUPPLY, 24VDC (2 EA.)
16 REDUNDANCY MODULE
17 24VDC POWER DISTRIBUTION TERMINALS
18 120VAC SURGE PROTECTOR
19 CP POWER DISTRIBUTION
20 DISCRETE TERMINAL BLOCKS
21 GROUND BAR
22 TEMPERATURE SWITCH
23 CONTROL RELAYS
24 NOT USED
25 LOCAL OPERATOR INTERFACE (LOI)
26 ELECTRONIC CIRCUIT PROTECTOR
27 COOLING FAN
28 EXHAUST GRILLE
141
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:21:48-06'00'
200

Page 380 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
lotD
ate: 06-APR
-2023
7:20:44
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
LMB

INSTRUMENTATION
8660F10 8660F1002N002.dgn
02N02
lbordelon
BAL
PCM-4 PANEL MODIFICATIONS
2 1
3 4
6 5
3 PCM-4 PANEL ELEVATION INTERIOR PCM-4 PANEL ELEVATION EXTERIOR EXISTING PLC-3 PANEL ELEVATION INTERIOR (NOT SHOWING THE COMPLETE INTERIOR)
# KEY NOTES:
7 8 9
9 REMOVED PER KEY NOTE 5.

THE SAME FUNCTIONALITY AS WAS PRESENT INCLUDING THE ITEMS NEW PLC. ADDITIONALLY, THE NEW PLC AND LOI SHALL PROVIDE

9. ALL EXISTING PROGRAMMING SHALL BE REPROGRAMMED IN THE SHALL BE INSTALLED ON THE PLATE SPECIFIED IN KEY NOTE 6.

SPECIFIED IN CONTRACT DRAWINGS AND SPECIFICATION 17721. LOI

8. PROVIDE AND INSTALL NEW LOCAL OPERATOR INTERFACE AS
THE PANEL'S NEMA RATING.

LIGHTS, SELECTOR SWITCHES, AND PUSH BUTTONS TO MAINTAIN

7. USE APPROPRIATE PLUGS TO INDIVIDUALLY COVER THE PILOT TO INSTALL THE NEW LOI.

BOLT A PLATE TO COVER THE HOLE. THIS PLATE SHALL BE UTILIZED

6. CUT ONE LARGE SQUARE HOLE IN THE AREA SHOWN, GASKET AND SCADA AS NEEDED.

FUNCTIONALITY SHALL BE REPLICATED ON THE NEW LOI AND

PUSH BUTTONS, PILOT LIGHTS, AND SELECTOR SWITCHES

CHART RECORDER, REDIPANEL KEYPAD MODULE, ANNUNCIATOR,
SELECTOR SWITCHES AND RETURN TO THE OWNER. EXISTING

MODULE, ANNUNCIATOR, PUSH BUTTONS, PILOT LIGHTS, AND

5. REMOVE EXISTING CHART RECORDER, REDIPANEL KEYPAD
SPECIFICATIONS.

MAY BE REQUIRED PER CONTRACT DRAWINGS AND

RELAYS, TERMINAL BLOCKS, FUSES AND CIRCUIT BREAKERS THAT

4. UTILIZE THE IDENTIFIED EMPTY SPACES AS NEEDED FOR ANY NEW TO THESE NEW PATCH PANELS AS SHOWN ON 04N02.

FIBER PATCH PANEL LOCATED IN PLC-3 AND SHALL BE CONNECTED PLC-12199 PANELS SHALL BE DISCONNECTED FROM THE EXISTING EXISTING FIBER CONNECTIONS COMING FROM PLC-70299 AND
TRACE AND FIELD VERIFY EXISTING FIBER CONNECTIONS. THE TWO SPECIFIED IN CONTRACT DRAWING AND SPECIFICATION 17733.

3. PROVIDE AND INSTALL NEW FIBER PATCH PANEL IN PLC-4 AS 04N02.

NETWORK CONNECTIONS AS SHOWN ON CONTRACT DRAWING
CONTRACT DRAWINGS AND SPECIFICATION 17733. CONNECT

PROCESSOR WAS PREVIOUSLY INSTALLED AS SPECIFIED IN

AND INSTALL ETHERNET SWITCH IN THE SPACE WHERE THE OLD

2. REMOVE PLC PROCESSOR AND RETURN TO THE OWNER. PROVIDE CONNECTED TO THE EXISTING PLC.

SAME SLOT NUMBER AND IO POINT AS THEY WERE PREVIOUSLY

POSSIBLE, TERMINATE EXISTING IO WIRES TO THE NEW PLC IN THE BEFORE REMOVING WIRES FROM THE EXISTING PLC. WHERE

VERIFY ALL EXISTING IO WIRING AND NETWORK CONNECTIONS
CONTRACT DRAWINGS AND SPECIFICATION 17720. TRACE AND FIELD OWNER. PROVIDE AND INSTALL NEW PLC AS SPECIFIED IN

1. REMOVE EXISTING PLC RACK AND MODULES AND RETURN TO THE 142
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:22:14-06'00'
200

Page 381 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
lotD
ate: 06-APR
-2023
8:32:55
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
LMB

INSTRUMENTATION
8660F10 8660F1002N003.dgn
02N03
crollins
BAL
1 # KEY NOTES:

PLC-70299 PANEL MODIFICATIONS
2 2
PLC-70299 PANEL ELEVATION INTERIOR
143
TERMINAL BLOCKS, FUSES AND RELAYS.

2. UTILIZE EMPTY AREAS IF ADDITIONAL SPACE IS REQUIRED FOR NEW NEW TERMINAL BLOCKS AND FUSES AS NEEDED.

HORIZONTAL SPACE CREATED BY THE SMALLER PLC CHASSIS FOR RELAYS TO TERMINATE NEW IO POINTS AS REQUIRED. UTILIZE

PROVIDE AND INSTALL DIN RAIL, TERMINAL BLOCKS, FUSES AND AS SHOWN ON CONTRACT DRAWING 04N03 AND SPECIFICATION.

PROVIDE AND INSTALL ETHERNET SWITCH AND FIBER PATCH PANEL

1. REMOVE EXISTING EMPTY PLC RACK AND RETURN TO THE OWNER.

Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:22:35-06'00'
200

Page 382 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
POWER
STATUS

ADDRESS/ERROR
ControlNet

MODULE NET
# KEY NOTES:
5 1
2 4
3 TOP OF GENERATOR BUILDING.

7. OMNIDIRECTIONAL BASE STATION ANTENNA. TO BE INSTALLED ON PUMP STATION.

6. COMMUNICATES WITH NEW TRANSCEIVER AT RECYCLED WATER

5. COMMUNICATES WITH NEW TRANSCEIVER AT WWTP.

CONTROL PANEL.

4. INSTALL COAXIAL CABLE SURGE PROTECTION DEVICE IN THE MAST.

3. MINIMUM 10 FT. LOOP OF ANTENNA CABLE AT BASE OF ANTENNA ENDS AGAINST WEATHER.

2. 10 FT. 2" GRC MAST FOR ANTENNA MOUNTING. CAP MAST BOTH

1. HIGH-GAIN YAGI ANTENNA.
2 4
3 7
1 3
2 4
PWR
FANS
ALARM
STATUS
HA
TEMP
USB
5 7
6 8
9 11
10 12
MA1
MA2
MGT

CONSOLE
CLEI

CONSOLE

NEARBY SCADA SYSTEM CABINET

SYSTEM INTERFACE LOCATED IN

DATA LINK TO EXISTING SCADA
PCM-99400

RADIO PANEL

RECYCLED WATER PUMP STATION
FW-99400
RAD1-99400
6 ANT1-99400
RAD2-99400
ANT2-99400
HMI-99400
SW-99400
PLC-99400
PQM-99400
99N001
PUMP #1

RECYCLED WATER
PMP-99411
PLC-99400 EIP
99N002
PUMP #2

RECYCLED WATER
PMP-99412
PLC-99400 EIP
99N002
PUMP #3

RECYCLED WATER
PMP-99413
PLC-99400 EIP
99N002
PUMP #4

RECYCLED WATER
PMP-99414
PLC-99400 EIP
99N003
PUMP #5

RECYCLED WATER
PMP-99415
PLC-99400 EIP

ELECTRICAL BUILDING
8 6
LNK
ACT
LNK
ACT
4 2
LNK
ACT
LNK
ACT
7 5
3 1
LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
!

LNK/ACT

LNK/ACT
X
2 F
X
1 F
LNK
GB1 ACT GB2

RADIO PANEL

POWER GENERATION BUILDING
WWTP

SWBD-RWPS
P
lotD
ate: 06-APR
-2023
8:19:54
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL
04N01
144

INSTRUMENTATION

RECYCLED WATER PUMP STATION

NETWORK BLOCK DIAGRAM
8660F1004N001.dwg
crollins
8660F10
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:55:01-06'00'
200

Page 383 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PLC1-4
LOI-4
LOI
ESP-4
12/FO-MM
FPP1-4

FIBER PATCH PANEL
GENERAL NOTES:

NEEDED FOR A FULLY FUNCTIONAL SYSTEM.

4. PROVIDE ADDITIONAL HARDWARE AND CONFIGURATION AS
OTHERWISE NOTED.

3. COMMUNICATION PROTOCOL SHALL BE ETHERNET/IP, UNLESS
PATCHED THROUGH TO DEVICES AS SHOWN.
(NOT SHOWN FOR CLARITY) OR SURGE PROTECTION DEVICE AND

ENCLOSURE SHALL BE MADE THROUGH COPPER PATCH PANELS

2. ALL COPPER CONNECTIONS FROM DEVICES EXTERNAL TO THE
CONNECTIONS, UNLESS NOTED OTHERWISE.

1. PROVIDE DUPLEX PATCH CABLES FOR ALL INTERNAL FIBER

BUILDING

EQUIPMENT
DAFT
PLC70299

BUILDING

GENERATION
POWER
PLC12199
12/FO-MM
FPP2-4

FIBER PATCH PANEL
PCM-4

TREATMENT BUILDING

ADVANCED WASTEWATER
VCP-3

WORKSTATION

EXISTING HMI

VENDOR CONTROL PANEL

AWT CLARIFIER/FILTER
P
lotD
ate: 06-APR
-2023
7:17:16
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
04N02

ADVANCED WASTEWATER TREATMENT

NETWORK BLOCK DIAGRAM
8660F1004N002.dwg
lbordelon
8660F10
145
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:23:11-06'00'
200

Page 384 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
12/FO-MM
FPP1-70299

FIBER PATCH PANEL
GENERAL NOTES:

SHOWN.

1. DRAWING REFLECTS NEW SCOPE. EXISTING CONNECTIONS NOT NJB-60001

DECHLORINATION FACILITY
FPP1-60001

FIBER PATCH PANEL
ESF-70299

ETHERNET SWITCH

TO EXISTING ETHERNET

CONNECTIONS
60N001
VALVE 1

DCL STRUCTURE
FV-60100
PLC-70299 EIP
PLC-70299

DAFT BUILDING
60N001
VALVE 2

DCL STRUCTURE
FV-60102
PLC-70299 EIP
LNK
ACT
SPD
1000
10/100/1000Base-T
RX
TX

LNK ACT
1000Base-SX/LX
LNK
ACT
SPD
1000
10/100/1000Base-T
RX
TX

LNK ACT
1000Base-SX/LX

ETHERNET SWITCH
MC1-60001

MEDIA CONVERTER
MC2-60001

MEDIA CONVERTER
89N001
CAROUSEL PUMP 1
PMP-89100
PLC-70299 EIP
89N001
CAROUSEL PUMP 2
PMP-89101
PLC-70299 EIP
89N001
CAROUSEL PUMP 3
PMP-89102
PLC-70299 EIP
91N001
PAU PUMP 1
PMP-99100
PLC-70299 EIP
P
lotD
ate: 06-APR
-2023
7:16:31
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

CGR

INSTRUMENTATION
04N03

DAFT BUILDING NETWORK BLOCK DIAGRAM
8660F1004N003.dwg
lbordelon
8660F10
DB
BAL
146
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:23:36-06'00'
200

Page 385 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
VFD-*
480V
MWH-*
CR1-*
SPD
H1 H3 H2 H4
X1 X2
M
VFD

RUNNING
1Ø CONTROL TRANSFORMER
480V PRI
120V SEC
CR

DI REMOTE
DO
PORT

PROGRAMMING
SERIAL

ETHERNET
IP
DO

RUNNING
HSC-*
START

oox

HSA-*
OFF

LOCAL REMOTE
xoo
DI
DO DO
TSH-*
DI
DI

DI SPARE
GROUND
GENERAL NOTES:

POWER (L) POWER (N)
PMP-*
SPEED
HSS-*
LOCAL
SPEED
* = 99411 PMP - 99411
* = 99413 PMP - 99413
* = 99414 PMP - 99414
AUX
3 -*
POWER
FSL-*

3. REFER TO SPECIFICATION 17101 FOR CONTROL DESCRIPTIONS.

INDICATED LOADS.

2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL BASED ON THE SELECTED MANUFACTURER.

THE OPERATION SHOWN HERE AND DESCRIBED IN 17100 AND 17101 MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM

1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
TAG LOOP REFERENCE DWG.
99N01

STOP
HSB-*
1 RECYCLED WATER PUMPS
99N01, 99N02

DI STOP

DI START
* = 99412 PMP - 99412 99N02
99N02
99N02
SPARE

MODULE (HM)

HUMAN INTERFACE

VFD KEYPAD/

COMPONENTS

SPECIFICATIONS FOR INPUT

DIAGRAMS AND

REFER TO ONE-LINE

DESIGN TOPOLOGY

AND SPECIFICATIONS FOR VFD

REFER TO ONE-LINE DIAGRAMS

OUTPUT COMPONENTS

SPECIFICATIONS FOR

DIAGRAMS AND

REFER TO ONE-LINE

HIGH TEMPERATURE

LOW FLOW
CR1-*
1 # KEY NOTES:

1. FLOW SWITCH SHALL BE RESET THROUGH THE PCS.

P
lotD
ate: 06-APR
-2023
7:19:47
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
TCD

INSTRUMENTATION
8660F10 8660F1006N001.dgn
06N01
CONTROL SCHEMATIC 1
BAL
147
crollins
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:24:34-06'00'
200

Page 386 of 1800 ends

120VAC

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
GENERAL NOTES:

KEY NOTES:

REQUIREMENTS.

COMPONENTS TO MEET PROJECT
ONLY. PROVIDE ALL NECESSARY

1. SCHEMATIC ILLUSTRATES DESIGN INTENT
#

RECEPTACLE
GFCI
6 120VAC SURGE PROTECTIVE DEVICE
24VDC SURGE PROTECTIVE DEVICE
H N G
8 2
2 (AS REQUIRED)

I/O POWER
(AS REQUIRED)

INSTRUMENT POWER
2 (AS REQUIRED)

PLC POWER SUPPLY
UL
UL
UL
G
G
G
N
N
N
2 (WHERE APPLICABLE)
LOI
UL
G
N
L1 N
GND
+ -
SUPPLY
POWER

SWITCHING
24VDC OUT
2 L1 N
GND
+ -
SUPPLY
POWER

SWITCHING
IN 1 IN 2
- +
+ -
24VDC OUT
UL
UL
G
G
N
N
+ -
XA4-*
SPD2 FAIL
INPUT

SIG COM

SIG COM

JS4-*
ACB OK
INPUT

JS3-*

REDUNDANCY OK
INPUT

SIG COM

JS2-*

POWER SUPPLY OK
INPUT

SIG COM

JS1-*

POWER SUPPLY OK
INPUT

SIG COM

INPUT

XA7-*

ECP-P FAIL
INPUT

XA5-*

ES-P FAIL
INPUT

(AS REQUIRED)

SIGNAL ISOLATORS
(AS REQUIRED)

INSTRUMENT POWER
(AS REQUIRED)

PLC I/O MODULES
-
-
-
+
+
+

LINE NEUTRAL GND
5 H THERMOSTAT N
3 CONDITIONER

CABINET FAN / AIR
9 9
G
LIGHT

CABINET
9 G
G
N
N
H
H
5A-1P
24VDC OUT

SIG COM

TSH-*

HIGH CABINET TEMP
INPUT

SWITCH

TEMPERATURE

SIG COM

ZS1-*

INTRUSION
INPUT

DOOR SWITCH
4 ECP

SIG COM

(PLC)

ETHERNET SWITCH
ES-P

SIG COM

-
G
+ -
2 TAG LOOP REFERENCE DWG.
2 5

LOCATED WITHIN PCM CABINET

CONTINUED AT UPPER RIGHT

CONTINUED AT LOWER LEFT

TERMINAL BLOCK LEGEND
PCM
H
N
G
UL
+
-
120VAC

NEUTRAL
GROUND
UPS 120VAC
24VDC (+)
24VDC (-)

SPD FAIL
(AS REQUIRED)

TELEMETRY RADIO
+ -

SPECIFICATIONS.

9. PROVIDE QUANTITY REQUIRED PER
PCM CABINET.

EACH INSTRUMENT POWERED FROM THE

PROVIDE SEPARATE CIRCUIT BREAKERS FOR

8. SIZE BASED ON PROTECTION NEEDS.

7. NOT USED.

LAPTOP.

SPECIFICATIONS. SIZE RECEPTACLE FOR

6. PROVIDE QUANTITY REQUIRED PER

5. SIZE BASED ON LOAD REQUIREMENT.

NON-OVERLAPPING DOORS.

SWITCHES, WIRED IN SERIES, FOR
OVERLAPPING DOORS. PROVIDE ADDITIONAL

4. INSTALL SWITCH ON OUTERMOST DOOR OF
CIRCUIT IF REQUIRED.

CALCULATIONS. PROVIDE ADDITIONAL

3. VERIFY LOADS BASED ON TEMPERATURE

2. SIZE BASED ON PROTECTION NEEDS.

1. NOT USED.

XA6-*
* = 99400 PCM-99400 99N04

DISCRETE-ANALOG PCM CABINET

PLC AND INSTRUMENT POWER
99N04
P
lotD
ate: 06-APR
-2023
7:19:54
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
TCD

INSTRUMENTATION
8660F10 8660F1006N002.dgn
06N02
CONTROL SCHEMATIC 2
BAL
148
awills
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:24:58-06'00'
200

Page 387 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
M PMP-*
TM
GND
480V
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
120VAC
MOV
CR3-*
CR

RUNNING
VFD
3 TAG LOOP REFERENCE DWG.

CAROUSEL PUMPS
89N01
* = 89100 PMP-89100
* = 89101 PMP-89101 89N01
89N01
* = 89102 PMP-89102 89N01
SPEED
LOCAL
HSS-*
SPEED

ETHERNET
IP
CR3-* MWH-*
TSH-*
DI
GENERAL NOTES:

DI

POWER
FSL-*
1 CONVERTER MODULES AS NEEDED FOR FUNCTIONALITY SHOWN.

3. PROVIDE EXPANSION MODULES AND ANY OTHER APPLICABLE
INDICATED LOADS.

2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL FOOTPRINT, WIRING CHANGES, ADDITIONAL CONTROL RELAYS, ETC.

OWNER, INCLUDING BUT NOT LIMITED TO DIFFERENCE IN MCC

NECESSARY DIFFERENCES WITH NO ADDITIONAL COST TO THE

SELECTED, CONTRACTOR IS RESPONSIBLE FOR PROVIDING FOR
THE OPERATION SHOWN HERE. IF ANOTHER MANUFACTURER IS
MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM

1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
# KEY NOTES:

FILTER
DV/DT

DI REMOTE
HSC-*
START

oox

HSA-*
OFF

LOCAL REMOTE
xoo

STOP
HSB-*

DI STOP

DI START

MODULE (HIM)

HUMAN INTERFACE

VFD KEYPAD/
VFD-*

LINE REACTOR

HIGH TEMPERATURE

LOW FLOW
SWITCH SHALL BE RESET THROUGH TO PCS.

FLOW ALARM SIGNAL SHALL BE SENT TO THE PLANT PLC. FLOW

SHUT OFF AFTER AN OPERATOR ADJUSTABLE TIMER AND A LOW
B. IN A LOW DISCHARGE FLOW CONDITION, THE EQUIPMENT SHALL BE SENT TO THE PLANT PLC.

SHALL SHUT OFF AND A HIGH TEMPERATURE ALARM SIGNAL SHALL A. IN A HIGH MOTOR TEMPERATURE CONDITION, THE EQUIPMENT HARDWIRED INTERLOCKS/OVERLOAD PROGRAMMED INTERLOCKS:

EQUIPMENT.

THE REMOTE POSITION, SCADA/HMI SHALL CONTROL THE
E. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN STARTED.

THE OFF POSITION, THE EQUIPMENT IS PROHIBITED FROM BEING D. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BY PRESSING THE STOP PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL STOP THE EQUIPMENT C. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN ADJUSTED USING THE SPEED POTENTIOMETER.

THE LOCAL POSITION, THE SPEED OF THE EQUIPMENT SHALL BE B. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BY PRESSING START PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL START THE EQUIPMENT A. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN

1. HARDWIRED CONTROLS:

P
lotD
ate: 06-APR
-2023
7:20:10
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N003.dgn
06N03
CONTROL SCHEMATIC 3
BAL
sshepard
149
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:25:15-06'00'
200

Page 388 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
120VAC
CR3-*
CR

RUNNING
VFD
4 TAG LOOP REFERENCE DWG.
91N01
* = 91100 PMP-91100 91N01

PAU PUMP
HSS-*
SPEED

DI
DI

POWER
FSL-*

ETHERNET
IP
DI
LSL-*
VFD-*
6 GENERAL NOTES:
# KEY NOTES:

SPEED
LOCAL
TSH-*
CR3-* MWH-*

MODULE (HIM)

HUMAN INTERFACE

VFD KEYPAD/

DI
LSHH-*
TM
GND
MOV
480V
M PMP-*
FILTER
DV/DT
CONVERTER MODULES AS NEEDED FOR FUNCTIONALITY SHOWN.

3. PROVIDE EXPANSION MODULES AND ANY OTHER APPLICABLE
INDICATED LOADS.

2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL FOOTPRINT, WIRING CHANGES, ADDITIONAL CONTROL RELAYS, ETC.

OWNER, INCLUDING BUT NOT LIMITED TO DIFFERENCE IN MCC

NECESSARY DIFFERENCES WITH NO ADDITIONAL COST TO THE

SELECTED, CONTRACTOR IS RESPONSIBLE FOR PROVIDING FOR
THE OPERATION SHOWN HERE. IF ANOTHER MANUFACTURER IS
MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM

1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED

DI REMOTE
HSC-*
START

oox

HSA-*
OFF

LOCAL REMOTE
xoo

STOP
HSB-*

DI STOP

DI START

LINE REACTOR

LOW FLOW

HIGH TEMPERATURE

LOW LEVEL

HIGH LEVEL
CAROUSEL PUMP NO. 3.

SIGNAL SHALL BE SENT TO THE PLANT PLC TO SHUT DOWN
D. IN HIGH HIGH LEVEL CONDITION, A HIGH HIGH LEVEL ALARM AND A LEVEL LOW SIGNAL SHALL BE SENT TO THE PLC.

C. IN LOW LEVEL CONDITION, THE EQUIPMENT SHALL SHUT OFF FLOW SWITCH SHALL BE RESET THROUGH THE PCS.

LOW FLOW ALARM SIGNAL SHALL BE SENT TO THE PLANT PLC.

SHUT OFF AFTER AN OPERATOR ADJUSTABLE TIMER AND A
B. IN A LOW DISCHARGE FLOW CONDITION, THE EQUIPMENT SHALL SHALL BE SENT TO THE PLANT PLC.

SHALL SHUT OFF AND A HIGH TEMPERATURE ALARM SIGNAL
A. IN A HIGH MOTOR TEMPERATURE CONDITION, THE EQUIPMENT HARDWIRED INTERLOCKS/OVERLOAD PROGRAMMED INTERLOCKS:

EQUIPMENT.

THE REMOTE POSITION, SCADA/HMI SHALL CONTROL THE
E. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BEING STARTED.

THE OFF POSITION, THE EQUIPMENT IS PROHIBITED FROM
D. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN EQUIPMENT BY PRESSING THE STOP PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL STOP THE
C. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN ADJUSTED USING THE SPEED POTENTIOMETER.

THE LOCAL POSITION, THE SPEED OF THE EQUIPMENT SHALL BE B. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN EQUIPMENT BY PRESSING START PUSH BUTTON.

THE LOCAL POSITION, AN OPERATOR SHALL START THE
A. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN

1. HARDWIRED CONTROLS:

P
lotD
ate: 06-APR
-2023
7:20:18
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N004.dgn
06N04
CONTROL SCHEMATIC 4
BAL
sshepard
150
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:26:40-06'00'
200

Page 389 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
M
M O.L.

HSA-*
LOCAL
OFF
REMOTE
xoo
HSB-*
STOP
HSC-*
START
AUX3-*
MS-*
MS-*
RUN
OUTPUT
oox
MS-*
M
3 O.L.'S
oox
HSAR-*
REMOTE
INPUT

AUX1-*

RUNNING
INPUT

AUX1-*
MS-*

SIG COM

TSH-*
INPUT

CR1-*
CR1-*
CR
TAG LOOP REFERENCE DWG.
5 CR1-*
MWH-*
AUX4-*
MS*-
* = 85104 PMP-85104 85N07
TSH-*
PMP-*
* = 87134 PMP-87134 87N01

RAPID MIX PUMP, SAMPLE PUMP
85N07, 87N01

HIGH TEMP
P
lotD
ate: 06-APR
-2023
7:20:25
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N005.dgn
06N05
CONTROL SCHEMATIC 5
BAL
151
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:26:56-06'00'
200

Page 390 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
M

WHERE INDICATED

REMOTE DISCONNECT
HSA-*
LOCAL
OFF
REMOTE
xoo
HSB-*
STOP
HSC-*
START
CR5-*
CR1-*
CR
TAG LOOP REFERENCE DWG.
6 MWH-*
* = 85106 BLO-85106 85N05
* = 85107 BLO-85107 85N05
TSH-*
BLO-*
85N05

AIR WASH BLOWERS
* = 85108 BLO-85108 85N05
MS-*
RUN
OUTPUT
oox
oox
HSAR-*
REMOTE
INPUT

AUX1-*

RUNNING
INPUT

SIG COM

TSH-*
INPUT

AUX2-*
INPUT
VCP-3

PRESS DIFF
CR2-*
CR
PDSH-*
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC
480V PRI
1PH CONTROL TRANSFORMER
M

WHERE INDICATED

REMOTE DISCONNECT
M O.L.

FAN-*
CR1-* CR2-* CR3-*
xoo
CR4-*
CR
INPUT

CR3-*
CR
MS-*
M
3 O.L.'S
MS-*
RUN
OUTPUT

AUX1-*

RUNNING
INPUT

VCP-3
AUX1-*
MS-*
TAG LOOP REFERENCE DWG.

FAN-85109 85N05
FAN-85110 85N05
FAN-85111 85N05
7 85N05

AIR WASH BLOWER FANS
* = 85109, **=85106
* = 85110, **=85107
* = 85111, **=85108
AUX3-*
PSH-*
CR2-*
CR1-*
CR3-*

BLOWER FILTER

MOTOR TEMP

DISCHARGE PRESS

CR4-*

BLOWER STARTER

AIR WASH
CR4-**
120VAC

RUNNING
RVSS
RVSS
RUN
CR5-*
RVSS-*
CR6-*
CR
CR
CR5-*
CR6-*
CR6-*

STARTER
MOTOR

BLOWER FAN

AIR WASH
P
lotD
ate: 06-APR
-2023
7:20:33
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
KIK

INSTRUMENTATION
8660F10 8660F1006N006.dgn
06N06
CONTROL SCHEMATIC 6
BAL
152
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:27:15-06'00'
200

Page 391 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
POWER_QUALITY_METER
POWER QUALITY METER POWER MONITOR M500 (PM500)
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
A PH DEMAND CURRENT ü ü
B PH DEMAND CURRENT ü ü
C PH DEMAND CURRENT ü ü
3 PH AVG DEMAND CURRENT ü ü ü
WATTS ü ü ü
VARS ü ü ü
VA ü ü ü
VA DEMAND ü ü ü
W DEMAND ü ü ü
ENERGY ü ü ü
FREQUENCY ü ü
POWER FACTOR ü ü ü
CAROUSEL_PUMP

CAROUSEL PUMP - VFD
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
DCL_STRUCTURE_VALVE

MULTI-TURN ACTUATOR
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK MOTOR CURRENT ü ü ü
LOCAL ü
OFF ü ü
REMOTE ü
OPEN ü ü
CLOSE ü ü
STOP ü ü
RUNNING CLOSE ü
RUNNING OPEN ü
CLOSE LIMIT ü ü ü
OPEN LIMIT ü ü ü
INSTANTANEOUS TORQUE ü ü ü ü
TORQUE ALARM ü ü ü
HIGH MOTOR TEMPERATURE ü ü ü
WATCHDOG TIMER ü
BATTERY LOW ü
RECYCLED_PUMP

RECYCLED PUMP - VFD
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
HIGH DISCHARGE PRESSURE ü ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
AWT_CLARIFIER_FILTER
VCP-3
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK HANDSHAKING ü ü
ALL SETPOINTS ü ü
AWT CLARIFIER/FILTER 1 READY ü
AWT CLARIFIER/FILTER 2 READY ü
AWT CLARIFIER/FILTER 3 READY ü
AWT CLARIFIER/FILTER 4 READY ü
BACKWASH IN PROGRESS ü
FLUSH IN PROGRESS ü
AIR WASH BLOWER 1 MODE AUTO ü ü
AIR WASH BLOWER 1 MOTOR STATUS STOPPED ü ü
AIR WASH BLOWER 1 MOTOR STATUS RUNNING ü ü
AIR WASH BLOWER 2 MODE AUTO ü ü
AIR WASH BLOWER 2 MOTOR STATUS STOPPED ü ü
AIR WASH BLOWER 2 MOTOR STATUS RUNNING ü ü
AIR WASH BLOWER 3 MODE AUTO ü ü
AIR WASH BLOWER 3 MOTOR STATUS STOPPED ü ü
COAGULANT PUMP 1 STATUS RUNNING OUTPUT ü ü
COAGULANT PUMP 2 STATUS RUNNING OUTPUT ü ü
COAGULANT PUMP 3 STATUS RUNNING OUTPUT ü ü
WASTE GATE VALVE 1 MODE AUTO ü ü
WASTE GATE VALVE 1 MODE POSITION ü ü
BACKWASH VALVE 1 MODE AUTO ü ü
BACKWASH VALVE 1 MODE POSITION ü ü
AC AIR SCOUR VALVE 1 MODE AUTO ü ü
AC AIR SCOUR VALVE 1 MODE POSITION ü ü
WASTE GATE VALVE 2 MODE POSITION ü ü
BACKWASH VALVE 2 MODE POSITION ü ü
AC AIR SCOUR VALVE 2 MODE POSITION ü ü
EFFLUENT VALVE 2 MODE AUTO ü ü
EFFLUENT VALVE 2 MODE POSITION ü ü
AWT CLARIFIER/FILTER 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 3 MODE STATUS ü ü
INFLUENT VALVE 3 MODE AUTO ü ü
AIR VALVE 3 MODE AUTO ü ü
WASTE GATE VALVE 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 4 MODE SEMI-AUTO ü ü
EFFLUENT VALVE 1 MODE POSITION ü ü
AWT CLARIFIER/FILTER 4 MODE AUTO ü ü
AWT CLARIFIER/FILTER 4 MODE STATUS ü ü
INFLUENT VALVE 4 MODE AUTO ü ü
INFLUENT VALVE 4 MODE POSITION ü ü
AIR VALVE 4 MODE AUTO ü ü
AIR VALVE 4 MODE POSITION ü ü
WASTE GATE VALVE 4 MODE AUTO ü ü
WASTE GATE VALVE 4 MODE POSITION ü ü
BACKWASH VALVE 4 MODE AUTO ü ü
AC AIR SCOUR VALVE 4 MODE AUTO ü ü
AC AIR SCOUR VALVE 4 MODE POSITION ü ü
EFFLUENT VALVE 4 MODE AUTO ü ü
EFFLUENT VALVE 4 MODE POSITION ü ü
AWT CLARIFIER/FILTER 1 CALL RUN COMMAND ü
AWT CLARIFIER/FILTER 2 CALL RUN COMMAND ü
AWT CLARIFIER/FILTER 4 CALL RUN COMMAND ü
AWT CLARIFIER/FILTER 4 INLET FLOW ü ü ü ü
COAGULANT FEED PUMP 1 COMMAND SPEED ü
COAGULANT FEED PUMP 2 COMMAND SPEED ü
COAGULANT FEED PUMP 3 COMMAND SPEED ü
AWT CLARIFIER/FILTER 3 INLET FLOW ü ü ü ü
INFLUENT VALVE 3 MODE POSITION ü ü
WASTE GATE VALVE 3 MODE POSITION ü ü
BACKWASH VALVE 3 MODE AUTO ü ü
EFFLUENT VALVE 3 MODE POSITION ü ü
BACKWASH VALVE 4 MODE POSITION ü ü
AWT CLARIFIER/FILTER 1 MODE SEMI-AUTO ü ü
AWT CLARIFIER/FILTER 1 MODE AUTO ü ü
AWT CLARIFIER/FILTER 1 MODE STATUS ü ü
INFLUENT VALVE 1 MODE AUTO ü ü
INFLUENT VALVE 1 MODE POSITION ü ü
AIR VALVE 1 MODE AUTO ü ü
AIR VALVE 1 MODE POSITION ü ü
EFFLUENT VALVE 1 MODE AUTO ü ü
INFLUENT VALVE 2 MODE POSITION ü ü
BACKWASH VALVE 3 MODE POSITION ü ü
AC AIR SCOUR VALVE 3 MODE AUTO ü ü
AC AIR SCOUR VALVE 3 MODE POSITION ü ü
EFFLUENT VALVE 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE SEMI-AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE STATUS ü ü
INFLUENT VALVE 2 MODE AUTO ü ü
AIR VALVE 2 MODE AUTO ü ü
AIR VALVE 2 MODE POSITION ü ü
WASTE GATE VALVE 2 MODE AUTO ü ü
BACKWASH VALVE 2 MODE AUTO ü ü
AC AIR SCOUR VALVE 2 MODE AUTO ü ü
AWT CLARIFIER/FILTER 3 MODE SEMI-AUTO ü ü
AIR VALVE 3 MODE POSITION ü ü
AWT CLARIFIER/FILTER 3 CALL RUN COMMAND ü
BACKWASH STATION LOW LEVEL OUTPUT ü
BACKWASH STATION HIGH LEVEL OUTPUT ü
AWT CLARIFIER/FILTER 1 INLET FLOW ü ü ü ü
AWT CLARIFIER/FILTER 2 INLET FLOW ü ü ü ü
AIR WASH BLOWER 3 MOTOR STATUS RUNNING ü ü
PAU_PUMP

PAU PUMP - VFD
PROTOCOL: EtherNet/IP

DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü ü
B PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü ü
B PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
LOW LEVEL ü ü ü
HIGH MOISTURE DETECTION ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
P
lotD
ate: 06-APR
-2023
7:20:02
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

DB
DKI

INSTRUMENTATION
8660F10 8660F1009N001.dgn
09N01

PCS I/O TABLES
BAL
153
M
Hood
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:43:30-06'00'
200

Page 392 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

PUMP STATION

TO CAROUSEL

FACILITY

FROM CHLORINATION
FV-60100
DCL STRUCTURE VALVE 1
5HP 480VAC 3PH
AE-60101
CHLORINE ANALYZER 4
0-10 MG/L
AE
60101

CHLORINE
AIT
60101
CB
60101
TM
120VAC-1P
PCM-70299
E
FV-60102
DCL STRUCTURE VALVE 2
5HP 480VAC 3PH

INJECTION STRUCTURE

FROM SODIUM BISULFATE
RIVER

TO RUSSIAN
EX- 42"
EX- 24" FE
EX- 42" RCP
P
O
W
ER
SOURC
E
FIELD
I/O
EX- 30" WSP
FV
60100
VAL
60100
A
60101
AI
CL
PLC-70299
E
DRAIN

REAGENT
DRAIN

PROCESS
PMP-60101

DCL CHLORINE SAMPLE PUMP

PMP
60101
E
M
PI-60101

PRESSURE INDICATOR
0-30 PSI
PI
60101

PRESSURE
FI
60101

CHLORINE
FI-60101

CHLORINE SAMPLE FLOW INDICATOR
0-500 ML/MIN
VAL
60102
FV
60102
TYP
*
NA090
CB
60100
TM
480VAC-3P
MCC70291
FVC
60100
EIP
PLC-70299
DCL_STRUCTURE_VALVE
CB
60102
TM
480VAC-3P
MCC70291
FVC
60102
EIP
PLC-70299
DCL_STRUCTURE_VALVE
PMP-60135

CHLORINE BASIN SAMPLE PUMP

DISC
60009
E
CB
60009
TM
480VAC-3P
MCC70291
E
HSG
60009
E OSC
HSA
60009
E LSR
FCV-60009

DCL STRUCT CHLORINE VALVE

E
D
HSAR
60009
DI
REMOTE
PLC-70299
E
ZSC
60009
DI
CLOSED
PLC-70299
E
ZSO
60009
DI
OPENED
PLC-70299
E
ZCO
60009
DO
OPEN
PLC-70299
E
ZCC
60009
DO
CLOSE
PLC-70299
E
M
DRAIN

PROCESS
PMP
60135
E
FCV
60009
E
VAL
60009
E
LCP
60009
E
HSA
60009
E LSR
HSG
60009
E OSC
ZSOC
60009
E

CHLORINE BASIN
1 1
# KEY NOTES:

AND BE INSTALLED IN THE EXISTING ENCLOSURE.

2. THE NEW ANALYZER SHALL REPLACE THE EXISTING ANALYZER ETHERNET SWITCH IN PANEL PLC-70299.

1. ETHERNET CONNECTION SHALL BE CONNECTED TO THE EXISTING DISC
60100
HSG
60100
OSC
HSA
60100
LSR
DISC
60102
HSG
60102
OSC
HSA
60102
LSR
ZSOC
60100
HSG
60100
OSC
HSA
60100
LSR
LCP
60100
ZSOC
60102
HSG
60102
OSC
HSA
60102
LSR
LCP
60102
E
D
E
D
2 P
lotD
ate: 06-APR
-2023
7:17:56
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
60N01

DECHLORINATION STRUCTURE P&ID
8660F1060N001.dwg
lbordelon
8660F10
154
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:43:46-06'00'
200

Page 393 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PIPE - SEGMENT 2

FROM CHLORINE CONTACT
LE-80100
STRUCT 80 LEVEL
0-18 FT
LE
80100

ULTRASONIC
LIT
80100
TYP
*
NL175
P
O
W
ER
SOURC
E
FIELD
I/O
L
80100
AI
PLC-70299

PUMP STATION
TO AWT
LSL
80011
E
LE-80011

LOW LEVEL SWITCH
LE
80011

E FLOAT
MM
FE-80002

RECLAIMED WATER FLOW TRANSMITTER
FE
80002

E MAGNETIC
FIT
80002
E
CB
80002
TM
120VAC-1P
PCM
E
LSL
80012
E
LE-80012

LOW LEVEL SWITCH
LE
80012

E FLOAT
LSL
80013
E
LE-80013

LOW LEVEL SWITCH
LE
80013

E FLOAT
96" SE

PUMP STATION

TO CAROUSEL
17 91N01
80N01

PUMP STATION

FROM PAU

WATER FILTER

TO RECLAIMED
30" FE
42" SE
6"RC
W
6"RC
W
6"RC
W
8" RCW
PMP
80111
E
PMP-80111
RECLAIMED WATER FILTER FEED PUMP 1

PMP
80112
E
PMP-80112
RECLAIMED WATER FILTER FEED PUMP 2

PMP
80113
E
PMP-80113
RECLAIMED WATER FILTER FEED PUMP 3

16" RW
P
lotD
ate: 06-APR
-2023
7:18:03
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
80N01
STRUCTURE 80 P&ID
8660F10 8660F1080N001.dwg
155
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:44:03-06'00'
200

Page 394 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
O
W
ER
SOURC
E
FIELD
I/O
MM
FE-85211
FLOW TRANSMITTER AWT CLARIFIER/FILTER 1
FE
85211

E MAGNETIC
FIT
85211
E
FV-85212
AIR VALVE NO.1

0.5HP 480VAC 3PH
DISC
85212
CB
85212
TM
480VAC-3P
DP2
E
M
VAL
85211
FBV
LSH
85101
FLOAT
FBV
TYP
*
LE1-85101 NL101
HIGH LEVEL SWITCH FILTER 1

7.17 FT
LE2-85101
LOW LEVEL SWITCH FILTER 1

6.17 FT
LE2
85101
FLOAT
FBV
LSL
85101
FLOAT
FBV
TYP
*
NL101
FCV-85218
EFFLUENT VALVE NO.1
1HP 480VAC 3PH
E
M
DISC
85218
FV-85217
BACKWASH VALVE NO.1

1.5HP 480VAC 3PH
DISC
85217

CLARIFIER
FILTER
20" WW
6" AA
TANK NO. 1
12" FE
ON
P
&
ID 85N02
CON
TINU
ED
FV
85212
FBV
HSA
85212
LSR
FBV
HSG
85212
OSC
FBV
ZSOC
85212
FBV
VAL
85212
FBV
GAT
85214
E
FCV-85211
INFLUENT VALVE NO.1
1HP 480VAC 3PH
DISC
85211
ZT
85211
FBV
HSA
85211
LSR
FBV
HSG
85211
OSC
FBV
ZSOC
85211
FBV
FCV
85211
FBV
FBV
FBV
FV-85214
WASTE GATE VALVE NO.1
1HP 480VAC 3PH
DISC
85214
FV
85214
FBV
ZSOC
85214
FBV
HSG
85214
OSC
FBV
HSA
85214
LSR
FBV
FCV
85218
FBV
FBV
ZSOC
85218
FBV
HSG
85218
OSC
FBV
HSA
85218
LSR
FBV
ZT
85218
FBV
VAL
85218
FBV
FBV
FV
85217
FBV
ZSOC
85217
FBV
HSG
85217
OSC
FBV
HSA
85217
LSR
FBV
VAL
85217
FBV
VCP
3 LE1
85101
FLOAT
FBV
CF
3 EIP
PLC-4
AWT_CLARIFIER_FILTER
PDIT
85213
E
PDIT
85216
E
12" FE
PE-85213

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85213

E PRESS DIFF
PE-85216

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85216

E PRESS DIFF

PUMP STATION

BACKWASH
14 85N04
85N01
TANK NO. 4 FILTER
13 85N03
85N01
TANK NO. 3 FILTER
12 85N02
85N01
TANK NO. 2 FILTER

PUMP STATION

BACKWASH
5 85N05
85N01

AIR WASH BLOWERS
VAL
85219
FBV
DISC
85219
CB
85219
TM
480VAC-3P
DP2
ZSOC
85219
FBV
HSA
85219
LSR
FBV
HSG
85219
OSC
FBV
FV-85219
AC AIR SCOUR VALVE NO. 1

0.5HP 480VAC 3PH
E
D
FV
85219
FBV

RECOVERY BASINS

WASHWATER

AWT PUMPS

AIR WASH BLOWERS
15 85N01
85N08
9 85N01
85N02
10 85N01
85N03
11 85N01
85N04
16 85N01
85N08
20" BW/FE
12" FE
CB
85210
TM
120VAC-1P
PNL-A
FBV
E
D
E
D
E
D
24" FE
TYP
*
LE-85211 NL180

RADAR PTOF
LE
85211

RADAR PTOF
FBV
LIT
85211
FBV
8" AA
P
lotD
ate: 06-APR
-2023
7:18:27
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
85N01
AWT CLARIFIER/FILTER 1 P&ID
8660F10 8660F1085N001.dwg
156
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:44:18-06'00'
200

Page 395 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
O
W
ER
SOURC
E
FIELD
I/O
MM
FE-85221
FLOW TRANSMITTER AWT CLARIFIER/FILTER 2
FE
85221

E MAGNETIC
FIT
85221
E
FV-85222
AIR VALVE NO.2

0.5HP 480VAC 3PH
DISC
85222
CB
85222
TM
480VAC-3P
DP2
E
M
VAL
85221
FBV
LSH
85102
FLOAT
FBV
TYP
*
LE1-85102 NL101
HIGH LEVEL SWITCH FILTER 2

7.17 FT
LE2-85102
LOW LEVEL SWITCH FILTER 2

6.17 FT
LE2
85102
FLOAT
FBV
LSL
85102
FLOAT
FBV
TYP
*
NL101
FCV-85228
EFFLUENT VALVE NO.2
1HP 480VAC 3PH
E
M
DISC
85228
FV-85227
BACKWASH VALVE NO.2

1.5HP 480VAC 3PH
DISC
85227
20" WW
12" FE
6" AA
TANK NO. 2
12" FE
ON
P
&
ID 85N03
CON
TINU
ED
FV
85222
FBV
HSA
85222
LSR
FBV
HSG
85222
OSC
FBV
ZSOC
85222
FBV
VAL
85222
FBV
FCV-85221
INFLUENT VALVE NO.2
1HP 480VAC 3PH
DISC
85221
ZT
85221
FBV
HSA
85221
LSR
FBV
HSG
85221
OSC
FBV
ZSOC
85221
FBV
FCV
85221
FBV
FBV
FBV
FV-85224
WASTE GATE VALVE NO.2
1HP 480VAC 3PH
DISC
85224
FV
85224
FBV
ZSOC
85224
FBV
HSG
85224
OSC
FBV
HSA
85224
LSR
FBV
FCV
85228
FBV
FBV
ZSOC
85228
FBV
HSG
85228
OSC
FBV
HSA
85228
LSR
FBV
ZT
85228
FBV
VAL
85228
FBV
FBV
FV
85227
FBV
ZSOC
85227
FBV
HSG
85227
OSC
FBV
HSA
85227
LSR
FBV
VAL
85227
FBV
ON
P
&
ID 85N01
CON
TINU
ED
LE1
85102
FLOAT
FBV

CLARIFIER FILTER
GAT
85224
E
VCP-3
PDIT
85223
E
PDIT
85226
E
PE-85223

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85223

E PRESS DIFF
PE-85226

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85226

E PRESS DIFF
DISC
85229
CB
85229
TM
480VAC-3P
DP2
FV-85229
AC AIR SCOUR VALVE NO. 2

0.5HP 480VAC 3PH
E
D
12 85N02
85N01

PUMP STATION

BACKWASH

PUMP STATION

BACKWASH
6 85N05
85N02

AIR WASH BLOWERS

RECOVERY BASINS

WASHWATER
9 85N01
85N02

AWT PUMPS

AIR WASH BLOWERS
FV
85229
FBV
VAL
85229
FBV
ZSOC
85229
FBV
HSG
85229
OSC
FBV
HSA
85229
LSR
FBV
12"FE
20" BW/FE
14" BW
FBV
E
D
E
D
E
D
TYP
*
LE-85221 NL180

RADAR PTOF
LE
85221

RADAR PTOF
FBV
LIT
85221
FBV
FBV
8" AA
P
lotD
ate: 06-APR
-2023
7:18:35
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
85N02
AWT CLARIFIER/FILTER 2 P&ID
8660F10 8660F1085N002.dwg
157
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:44:34-06'00'
200

Page 396 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
O
W
ER
SOURC
E
FIELD
I/O
MM
FE-85231
FLOW TRANSMITTER AWT CLARIFIER/FILTER 3
FE
85231

E MAGNETIC
FIT
85231
E
FV-85232
AIR VALVE NO.3

0.5HP 480VAC 3PH
DISC
85232
CB
85232
TM
480VAC-3P
DP2
E
M
VAL
85231
FBV
LSH
85103
FLOAT
FBV
TYP
*
LE1-85103 NL101
HIGH LEVEL SWITCH FILTER 3

7.17 FT
LE2-85103
LOW LEVEL SWITCH FILTER 3

6.17 FT
LE2
85103
FLOAT
FBV
LSL
85103
FLOAT
FBV
TYP
*
NL101
FCV-85238
EFFLUENT VALVE NO.3
1HP 480VAC 3PH
E
M
DISC
85238
FV-85237
BACKWASH VALVE NO.3

1.5HP 480VAC 3PH
DISC
85237
20" WW
12" FE
6" AA
TANK NO. 3
ON
P
&
ID 85N04
CON
TINU
ED
FV
85232
FBV
HSA
85232
LSR
FBV
HSG
85232
OSC
FBV
ZSOC
85232
FBV
VAL
85232
FBV
FCV-85231
INFLUENT VALVE NO.3
1HP 480VAC 3PH
DISC
85231
ZT
85231
FBV
HSA
85231
LSR
FBV
HSG
85231
OSC
FBV
ZSOC
85231
FBV
FCV
85231
FBV
FBV
FBV
FV-85234
WASTE GATE VALVE NO.3
1HP 480VAC 3PH
DISC
85234
FV
85234
FBV
ZSOC
85234
FBV
HSG
85234
OSC
FBV
HSA
85234
LSR
FBV
FCV
85238
FBV
FBV
ZSOC
85238
FBV
HSG
85238
OSC
FBV
HSA
85238
LSR
FBV
ZT
85238
FBV
VAL
85238
FBV
FBV
FV
85237
FBV
ZSOC
85237
FBV
HSG
85237
OSC
FBV
HSA
85237
LSR
FBV
VAL
85237
FBV
ON
P
&
ID 85N02
CON
TINU
ED
LE1
85103
FLOAT
FBV

CLARIFIER
FILTER
GAT
85234
E
VCP-3
PDIT
85233
E
PDIT
85236
E
PE-85233

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85233

E PRESS DIFF
PE-85236

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85236

E PRESS DIFF
DISC
85239
CB
85239
TM
480VAC-3P
DP2
FV-85239
AC AIR SCOUR VALVE NO. 3

0.5HP 480VAC 3PH
E
D
13 85N03
85N01

PUMP STATION

BACKWASH

PUMP STATION

BACKWASH
7 85N05
85N03

AIR WASH BLOWERS

RECOVERY BASINS

WASHWATER
10 85N01
85N03

AWT PUMPS

AIR WASH BLOWERS
FV
85239
FBV
ZSOC
85239
FBV
VAL
85239
FBV
HSG
85239
OSC
FBV
HSA
85239
LSR
FBV
12"FE
20" BW/FE
14" BW
FBV
FBV
E
D
E
D
18" FE
E
D
TYP
*
LE-85231 NL180

RADAR PTOF
LE
85231

RADAR PTOF
FBV
LIT
85231
8" AA
P
lotD
ate: 06-APR
-2023
7:18:43
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
85N03
AWT CLARIFIER/FILTER 3 P&ID
8660F10 8660F1085N003.dwg
158
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:44:55-06'00'
200

Page 397 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
O
W
ER
SOURC
E
FIELD
I/O
MM
FE-85241
FLOW TRANSMITTER AWT CLARIFIER/FILTER 4
FE
85241

E MAGNETIC
FIT
85241
E
FV-85242
AIR VALVE NO.4

0.5HP 480VAC 3PH
DISC
85242
CB
85242
TM
480VAC-3P
DP2
E
M
VAL
85241
FBV
LSH
85104
FLOAT
FBV
TYP
*
LE1-85104 NL101
HIGH LEVEL SWITCH FILTER 4

7.17 FT
LE2-85104
LOW LEVEL SWITCH FILTER 4

6.17 FT
LE2
85104
FLOAT
FBV
LSL
85104
FLOAT
FBV
TYP
*
NL101
FCV-85248
EFFLUENT VALVE NO.4
1HP 480VAC 3PH
E
M
DISC
85248
FV-85247
BACKWASH VALVE NO.4

1.5HP 480VAC 3PH
DISC
85247
20" WW
12" FE
TANK NO. 4
ON
P
&
ID 85N05
CON
TINU
ED
FV
85242
FBV
HSA
85242
LSR
FBV
HSG
85242
OSC
FBV
ZSOC
85242
FBV
VAL
85242
FBV
FCV-85241
INFLUENT VALVE NO.4
1HP 480VAC 3PH
DISC
85241
ZT
85241
FBV
HSA
85241
LSR
FBV
HSG
85241
OSC
FBV
ZSOC
85241
FBV
FCV
85241
FBV
FBV
FBV
FV-85244
WASTE GATE VALVE NO.4
1HP 480VAC 3PH
DISC
85244
FV
85244
FBV
ZSOC
85244
FBV
HSG
85244
OSC
FBV
HSA
85244
LSR
FBV
FCV
85248
FBV
FBV
ZSOC
85248
FBV
HSG
85248
OSC
FBV
HSA
85248
LSR
FBV
ZT
85248
FBV
VAL
85248
FBV
FBV
FV
85247
FBV
ZSOC
85247
FBV
HSG
85247
OSC
FBV
HSA
85247
LSR
FBV
VAL
85247
FBV
ON
P
&
ID 85N03
CON
TINU
ED
LE1
85104
FLOAT
FBV

CLARIFIER
FILTER
GAT
85244
E
VCP-3
PDIT
85243
E
PDIT
85246
E
PE-85243

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85243

E PRESS DIFF
PE-85246

PRESSURE DIFFERENTIAL TRANSMITTER
PE
85246

E PRESS DIFF
DISC
85249
CB
85249
TM
480VAC-3P
DP2
FV-85249
AC AIR SCOUR VALVE NO. 4

0.5HP 480VAC 3PH
E
D
14 85N04
85N01

PUMP STATION

BACKWASH

PUMP STATION

BACKWASH
8 85N05
85N04

AIR WASH BLOWERS

RECOVERY BASINS

WASHWATER
11 85N01
85N04

AWT PUMPS

AIR WASH BLOWERS
FV
85249
FBV
ZSOC
85249
FBV
HSG
85249
OSC
FBV
VAL
85249
FBV
HSA
85249
LSR
FBV
12"FE
20" BW/FE
14" BW
FBV
FBV
E
D
E
D
E
D
TYP
*
LE-85241 NL180

RADAR PTOF
LE
85241

RADAR PTOF
FBV
LIT
85241
FBV
8" AA
6" AA
P
lotD
ate: 06-APR
-2023
7:19:06
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
85N04
AWT CLARIFIER/FILTER 4 P&ID
8660F10 8660F1085N004.dwg
159
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:55:53-06'00'
200

Page 398 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
BLO-85106
AIR WASH BLOWER 1
20HP 480VAC 3PH
MWH
85106
TSH
85106
BLO
85106
6 06N06
4" AA
P
O
W
ER
SOURC
E
FIELD
I/O
BLO-85107
AIR WASH BLOWER 2
20HP 480VAC 3PH
4" AA
BLO-85108
AIR WASH BLOWER 3
20HP 480VAC 3PH
4" AA
BLO
85107
BLO
85108
TSH
85107
MWH
85107
TSH
85108
MWH
85108
FE-85105

AIR WASH VENTURI FLOWMETER
FE
85105

E VENTURI
FIT
85105
E SORT
F
85105
AI
PLC-4
E
PI-85100

PRESSURE INDICATOR
PI
85100
FBV
TYP
*
PE-85100 NP501

LOW PRESSURE SWITCH
PE
85100

PRESS SW
FBV
PSL
85100
FBV
VCP-3 CONTINUED
FR
O
M 85N04
CON
TINU
ED

PRESS DIFF
TEMP

RUNNING
REMOTE
RUN

PRESS DIFF
TEMP

RUNNING
REMOTE
RUN

PRESS DIFF
TEMP

RUNNING
REMOTE
RUN
5 85N05
85N01
FILTER NO. 1

OUTSIDE AIR
6 85N05
85N02
FILTER NO. 2
7 85N05
85N03
FILTER NO. 3
8 85N05
85N04
FILTER NO. 4
CLARIFIER NO. 1
CLARIFIER NO. 2
CLARIFIER NO. 3
CLARIFIER NO. 4

OUTSIDE AIR

OUTSIDE AIR
RVSS-85106
RVSS
480VAC-3P
MCC-C
RVSS-85107
RVSS
480VAC-3P
MCC-C
RVSS-85108
RVSS
480VAC-3P
MCC-C
HSB
85108
STOP
HSC
85108
START
HSA
85108
LOR
HSB
85107
STOP
HSC
85107
START
HSA
85107
LOR
HSB
85106
STOP
HSC
85106
START
HSA
85106
LOR
LCP
85106
LCP
85108
LCP
85107
ON 85N08
CON
TINU
ED
PE1-85106
FILTER DIFFERENTIAL PRESSURE 1
PE1
85106

PRESS DIFF
FBV
PDSH
85106
FBV
TYP
*
NP188 PE1-85107
FILTER DIFFERENTIAL PRESSURE 2
PE1
85107

PRESS DIFF
FBV
PDSH
85107
FBV
TYP
*
NP188 PE1-85108
FILTER DIFFERENTIAL PRESSURE 3
PE1
85108

PRESS DIFF
FBV
PDSH
85108
FBV
TYP
*
NP188
TYP
*
PE2-85106 NP501

PRESSURE SWITCH HIGH
PE2
85106

PRESS SW
FBV
PSH
85106
FBV
PE3-85106

PRESSURE TRANSMITTER
PE3
85106

PRESSURE
FBV
PIT
85106
FBV
TYP
*
NP501
FAN
85109
MS-85109
FVNR
480VAC-3P
MCC-C
MS-85110
FVNR
480VAC-3P
MCC-C
MS-85111
FVNR
480VAC-3P
MCC-C
PE2-85107

PRESSURE SWITCH HIGH
PE2
85107

PRESS SW
FBV
PSH
85107
FBV
PE3-85107

PRESSURE TRANSMITTER
PE3
85107

PRESSURE
FBV
PIT
85107
FBV
PE2-85108

PRESSURE SWITCH HIGH
PE2
85108

PRESS SW
FBV
PSH
85108
FBV
PE3-85108

PRESSURE TRANSMITTER
PE3
85108

PRESSURE
FBV
PIT
85108
FBV

PRESS PRESS PRESS
PER
M
ISS
IVE
PER
M
ISS
IVE
PER
M
ISS
IVE

RUNNING
RUN

RUNNING
RUN

RUNNING
RUN
TYP
*
NP501
TYP
*
NP501
TYP
*
NP501
TYP
*
6 NP501
06N06
6 06N06
7 06N06
7 06N06
7 06N06
FAN
85110
FAN
85111
8" AA 8" AA
8"AA
EX-6" AA
P
lotD
ate: 07-APR
-2023 1:48:04
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL
85N05
160

INSTRUMENTATION
AIR WASH BLOWERS 1, 2 & 3 P&ID
8660F1085N005.dwg
crollins
8660F10
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:55:21-06'00'

Page 399 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
LE-85180
TNK 2 LEVEL
LE
85180

E ULTRASONIC
LIT
85180
E
CB
85180
TM
120VAC-1P
PCM-4
E
PMP-85181
COAGULANT FEED PUMP NO. 1

0.5HP 90VDC
PMP
85181
FBV
E
VCP
85181
FBV
E
CB
85181
TM
120VAC-1P
PNL-A
E
PMP-85182
COAGULANT FEED PUMP NO. 2

0.5HP 90VDC
CB
85182
TM
120VAC-1P
PNL-A
E
PMP-85183
COAGULANT FEED PUMP NO. 3

0.5HP 90VDC
CB
85183
TM
120VAC-1P
PNL-A
E

WITH FERRIC CHLORIDE
TANK 2
EX-1 1/2" FC
P
O
W
ER
SOURC
E
FIELD
I/O
L
85180
AI
PLC-4
E
AUX1
85181
DI

RUNNING
PLC-4
E
AUX2
85181
DI
E-STOP
PLC-4
E
AUX1
85182
DI

RUNNING
PLC-4
E
AUX2
85182
DI
E-STOP
PLC-4
E
VCP
85182
FBV
E
PMP
85182
FBV
E
VCP
85183
FBV
E
AUX1
85183
DI

RUNNING
PLC-4
E
AUX2
85183
DI
E-STOP
PLC-4
E
PMP
85183
FBV
NPW
18 85N06
85N07

TO AWT RAPID MIX
S
S
S
FI
85181
E
FI-85181
ROTAMETER 1
0-5 GPM
FI
85182
E
FI-85182
ROTAMETER 2
0-5 GPM
FI
85183
E
FI-85183
ROTAMETER 3
0-5 GPM
SS
85182
AO

SPEED OUT
PLC-4
E
SS
85183
AO

SPEED OUT
PLC-4
E
SS
85181
AO

SPEED OUT
PLC-4
E
NPW - 2"
1 # KEY NOTES:

ENCLOSURE.

1. INSTALL NEW DC DRIVE AND ENCODER IN THE EXISTING
P
lotD
ate: 06-APR
-2023
7:17:31
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
85N06

COAGULANT FEED PUMP P&ID
8660F1085N006.dwg
crollins
8660F10
161
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:45:11-06'00'
200

Page 400 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

CHLORINATION FACILITY CLARIFIER/FILTER UNITS
FROM
PMP-85104

RAPID MIX PUMP

7.5HP 480VAC 3PH
5 06N05

ASSEMBLY

FLASH MIX
3" FE
P
O
W
ER
SOURC
E
FIELD
I/O
MS
85104
DO
RUN
PLC-4
HSAR
85104
DI
REMOTE
PLC-4
TSH
85104
DI

HIGH TEMP
PLC-4
AUX1
85104
DI

RUNNING
PLC-4
MWH
85104
TSH
85104
PMP
85104
FVNR-85104
FVNR
480VAC-3P
MCC-C
HSB
85104
STOP
HSC
85104
START
HSA
85104
LOR
LCP
85104
18 85N06
85N07

COAGULANT FEED
FROM
EX-24" FE
P
lotD
ate: 06-APR
-2023
7:17:39
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
85N07

RAPID MIX PUMP P&ID
8660F10 8660F1085N007.dwg
162
lbordelon
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:45:25-06'00'
200

Page 401 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON
ORIGINAL DRAWING 0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
123456789 10 11 12 13
ABCDEF
123456789 10 11 12 13

ABCDEFG
G
®
No. 22911

POW ER SOURCE FIELD I/O
VCP-3
FROM 85N05

CONTINUED
16 85N01
85N08
RCW
15 85N01
85N08
RCW
M
AE-85108
pH
AE
85108
E pH
AIT
85108
E
AE-85109

TURBIDITY
AE
85109

E TURBIDITY
AIT
85109
E
AE-85110
pH
AE
85110
E pH
AIT
85110
E
AE-85111

TURBIDITY
AE
85111

E TURBIDITY
AIT
85111
E
PMP
85112
E
PMP-85112

TO DRAIN

TO DRAIN
SINK

TO SAMPLE
SINK

TO SAMPLE
SHEET87N01

CONTINUED ON
PlotDate: 06-APR-2023 7:16:25AM User:svcPW Model:Layout1 ColorTable:gshade.ctb DesignScript:Carollo_Std_Pen_v0905.pen PlotScale:1:1 PROJECT NO. FILE NAME:

DB
LMB
BAL

INSTRUMENTATION
85N08

EXISTING CHLORINATION FACILITY

ANALYZERS P&ID
8660F1085N008.dwg
lbordelon
8660F10
163
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:45:40-06'00'
200

Page 402 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911

FROM AWT
19 87N01
88N01
BASINS

TO CHLORINE CONTACT
PMP-87132
BACKWASH PUMP NO. 1

AE-87130
CHLORINE ANALYZER 3
0-10 MG/L
AE
87130
CL
AIT
87130
CB1
87130
TM
120VAC-1P
PCM-4
TYP
*
NA090 PMP-87133
BACKWASH PUMP 2

LE/LSH-87130

HIGH LEVEL SWITCH
LSH
87130
E
LE-87130

LOW LEVEL SWITCH
LE
87130
E
LSL
87130
E

FROM HOCL
20 87N01
88N01
BASINS

TO CHLORINE CONTACT

TO AWT BUILDING
14" BW
24" FE
24" FE 24" FE
2" CLS
P
O
W
ER
SOURC
E
FIELD
I/O
LSL
87130
DI
PLC-4
E
LSH
87130
DI
PLC-4
E
A
87130
AI
CL
PLC-4
MWH
87132
E
TSH
87132
E
AUX1
87132
DI
READY
PLC-4
E
AUX2
87132
DI
FAILED
PLC-4
E
MS
87132
DO
RUN
PLC-4
E
PMP
87132
E
MWH
87133
E
TSH
87133
E
AUX1
87133
DI
READY
PLC-4
E
AUX2
87133
DI
FAILED
PLC-4
E
MS
87133
DO
RUN
PLC-4
E
PMP
87133
E
LE/LSH
87130
E
HSA
87133
E HOA
HSC
87133
E RUN
HSB
87133
E OFF
HSA
87132
E HOA
HSC
87132
E RUN
HSB
87132
E OFF
LCP
87132
E
LCP
87133
E
PMP-87134

BACKWASH CHLORINE SAMPLE PUMP

0.5HP 480VAC 3PH
FVNR-87134
FVNR
480VAC-3P
MCC-C
HSB
87134
STOP
HSC
87134
START
HSA
87134
LOR
5 06N05
PMP
87134
M
PI
87130

PRESSURE
PI-87130

PRESSURE INDICATOR
0-30 PSI
FI
87130

CHLORINE
FI-87130

CHLORINE SAMPLE FLOW INDICATOR
0-500 ML/MIN
DRAIN

PROCESS
DRAIN

REAGENT
MWH
87134
TSH
87134
LCP
87134
MS-87133
FVNR
480VAC-3P
MCCE
MS-87132
FVNR
0VAC-2P
MCCE
AUX1
87134
DI

RUNNING
PLC-4
TSH
87134
DI

HIGH TEMP
PLC-4
HSAR
87134
DI
REMOTE
PLC-4
MS
87134
DO
RUN
PLC-4
1 # KEY NOTES:

AND BE INSTALLED IN THE EXISTING ENCLOSURE.

1. THE NEW ANALYZER SHALL REPLACE THE EXISTING ANALYZER DISC
87130
FV-87130

HIGH RATE BACKWASH VALVE
1HP 480VAC 3PH
M
FV
87130
FBV
FR
O
M 85N08
CON
TINU
ED
8" BW
ZSOC
87130
FBV
HSG
87130
OSC
FBV
HSA
87130
LSR
FBV
VAL
87130
FBV
CB2
87130
TM
480VAC-3P
DP2
VCP-3
VCP
87130
P
lotD
ate: 07-APR
-2023
4:02:58
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL
87N01
164

INSTRUMENTATION

BACKWASH PUMP STATION

CHLORINE ANALYZER P&ID
8660F1087N001.dwg
crollins
8660F10
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 17:34:01-06'00'

Page 403 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
19 87N01
88N01

PUMPING STATION

BACKWASH
P
O
W
ER
SOURC
E
FIELD
I/O
LE-88101
CHLORINE CONTACT BASIN OPEN CHANNEL FLOW METER 1
600-1500 GPM
LE
88101

ULTRASONIC
FIT
88101
CB
88101
TM
120VAC-1P
PCM-4
TYP
*
NA901
F
88101
AI
PLC-4
LE-88102
CHLORINE CONTACT BASIN OPEN CHANNEL FLOW METER 2
600-1500 GPM
LE
88102

ULTRASONIC
FIT
88102
CB
88102
TM
120VAC-1P
PCM-4
F
88102
AI
PLC-4
20 87N01
88N01

PUMPING STATION

BACKWASH

INJECTION STRUCTURE

SODIUM BISULFITE

INJECTION STRUCTURE

SODIUM BISULFITE
TYP
*
NA901
24" FE
24" FE 24" FE
24" FE
CHLORINE CONTACT BASIN 1
CHLORINE CONTACT BASIN 2
P
lotD
ate: 06-APR
-2023
7:16:36
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
LMB
BAL

INSTRUMENTATION
88N01

CHLORINE CONTACT BASIN

FLOW METERS P&ID
8660F1088N001.dwg
lbordelon
8660F10
165
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:47:37-06'00'
200

Page 404 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
O
W
ER
SOURC
E
FIELD
I/O
PMP-89100
CAROUSEL PUMP 1
40HP 480VAC 3PH
HSS
89100
SPEED
VFD-89100
VFD-6
480VAC-3P
3 06N03
HSB
89100
STOP
HSC
89100
START
HSA
89100
LOR
PMP-89102
CAROUSEL PUMP 3
40HP 480VAC 3PH
HSS
89102
SPEED
VFD-89102
VFD-6
480VAC-3P
MCC70293
3 06N03
HSB
89102
STOP
HSC
89102
START
HSA
89102
LOR
PMP-89101
CAROUSEL PUMP 2
40HP 480VAC 3PH
PMP
89101
E
MWH
89101
TSH
89101
HSS
89101
SPEED
VFD-89101
VFD-6
480VAC-3P
MCC70292
HSB
89101
STOP
HSC
89101
START
HSA
89101
LOR
LCP
89101
3 06N03
LCP
89100
MWH
89100
TSH
89100
PMP
89100
E
LCP
89102
MWH
89102
TSH
89102
PMP
89102
TYP
*
LE-89103 NL153

CAROUSEL LEVEL TRANSMITTER
0-19.5 FT
LE
89103

RADAR PTOF
LIT
89103
L
89103
AI
PLC-70299
TYP
*
FE-89100 NF111

LOW FLOW SWITCH
400 GPM
FE
89100

THERMAL
FSL
89100
VFD
89101
EIP
PLC-70299
CAROUSEL_PUMP
VFD
89102
EIP
PLC-70299
CAROUSEL_PUMP
VFD
89100
EIP
PLC-70299
CAROUSEL_PUMP
FE-89101

LOW FLOW SWITCH
400 GPM
FE
89101

THERMAL
FSL
89101
FE-89102

LOW FLOW SWITCH
2000 GPM
FE
89102

THERMAL
FSL
89102
TYP
*
NF111
TYP
*
NF111

FACILITY

CHLORINATION
POND NO. 3 (NORTH)
POND NO. 2 (SOUTH)
POND NO. 1 (MIDDLE)
PAU
LE-89100

HIGH HIGH AND LOW LOW LEVEL SWITCHES
LE
89100
FLOAT
LSLL
89100
2 FT
LSHH
89100

17.5 FT
TYP
*
NL100
LSLL
89100
DI
PLC-70299
LSHH
89100
DI
PLC-70299
CB
89100
TM
480VAC-3P
MCC70291
CB
89101
TM
480VAC-3P
MCC70292
CB
89102
TM
480VAC-3P
MCC70293
1 1
# KEY NOTES:

TO ELECTRICAL DRAWINGS FOR FURTHER DETAIL.

1. EXISTING MOTOR SHALL BE REPLACED WITH NEW ONE. REFER P
lotD
ate: 06-APR
-2023
7:18:20
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
TCD
BAL

INSTRUMENTATION
89N01

CAROUSEL PUMP & LEVEL CONTROLS P&ID
8660F1089N001.dwg
lbordelon
8660F10
166
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:47:55-06'00'
200

Page 405 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
P
O
W
ER
SOURC
E
FIELD
I/O
PMP-91100
PAU PUMP NO. 1
10HP 480VAC 3PH
VFD-91100
VFD-6
480VAC-3P
MCC70293
TSH
91100
MWH
91100
HSB
91100
STOP
HSC
91100
START
HSA
91100
LOR
PMP
91100
LCP
91100
4 06N04
HSS
91100
SPEED
VFD
91100
EIP
PLC-70299
PAU_PUMP
FE-91100

LOW FLOW SWITCH
875 GPM
FE
91100

THERMAL
FSL
91100
TYP
*
NF111
PAU
17 91N01
80N01
STRUCTURE 80
LE-91101

HIGH HIGH AND LOW LEVEL SWITCHES
LE
91101
FLOAT
LSL
91101
2 FT
LSHH
91101
7 FT
TYP
*
NL100
CB
91100
TM
480VAC-3P
MCC70293
P
lotD
ate: 06-APR
-2023
7:18:50
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
KIK
BAL

INSTRUMENTATION
91N01

PAU PUMP STATION P&ID
8660F1091N001.dwg
crollins
8660F10
167
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:48:11-06'00'
200

Page 406 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PMP-99411
RECYCLED WATER PUMP #1
75HP 480VAC 3PH
1 06N01
HSA
99411
LOR
HSC
99411
START
HSB
99411
STOP
HSS
99411
SPEED
PI-99411

PRESSURE INDICATOR
0-150 PSIG
PI
99411

PRESSURE
FE-99411

THERMAL LOW FLOW SWITCH
450 GPM
FE
99411

THERMAL
FSL
99411
DISC
99411
TSH
99411
MWH
LCP 99411
99411
PMP
99411
LE-99405

LEVEL TRANSMITTER
0-25 FT
LE
99405
P-SUB
LIT
99405
TYP
*
NL132
NL133
HH LEVEL 25 FT
LL LEVEL 1 FT
LE-99403

LEVEL FLOAT SWITCHES
LE
99403
FLOAT
LSLL
99403
1 FT
TYP
*
NL108
LSHH
99403
25 FT
TNK
99401

RECYCLED WATER DISTRIBUTION TANK
16" RW
LSLL
99403
DI
PLC-99400
L
99405
AI
PLC-99400
S S
VAL-99402

TANK FILL VALVE

H
ZSC
99402
DI
CLOSED
PLC-99400
ZSO
99402
DI
OPENED
PLC-99400
ZCO1
99402
DO
OPEN
PLC-99400
ZCC1
99402
DO
CLOSE
PLC-99400
ZCO2
99402
DO
OPEN
PLC-99400
ZCC2
99402
DO
CLOSE
PLC-99400
SV1
99402
VAL
99402
SV2
99402
ZSOC
99402
25 FT
1 FT
16" RW
14" RW
16" RW
TYP
*
NF111
# KEY NOTES:

1. CABLE TERMINATION BOX.
1 DESICCANT
LSHH
99403
DI
PLC-99400
FE-99406

FLOW METER
500-4000 GPM
12"
FE
99406

MAGNETIC
FIT
99406
CB
99406
TM
120VAC-1P
PCM-99400
TYP
*
NF130
NF136
F
99406
AI
PLC-99400
16" RW MM 12" RW
16" RW

OVERFLOW
VFD
99411
EIP
PLC-99400
RECYCLED_PUMP
P
O
W
ER
SOURC
E
FIELD
I/O
CB
99411
TM
480VAC-3P

SWBD-RWPS
VFD-99411
VFD-RH
480VAC-3P

SWBD-RWPS

WATER SYSTEM
PHASE 1-3 RECYCLED
1 99N01
99N02

PUMP STATION

RECYCLED WATER
2 99N01
99N02

PUMP STATION

RECYCLED WATER
TYP
*
NP502
P
lotD
ate: 06-APR
-2023
7:16:40
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
99N01
RECYCLED WATER PUMP STATION 1 P&ID
8660F1099N001.dwg
crollins
8660F10
168
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:48:29-06'00'
200

Page 407 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PMP-99412
RECYCLED WATER PUMP #2
75HP 480VAC 3PH
1 06N01
HSA
99412
LOR
HSC
99412
START
HSB
99412
STOP
HSS
99412
SPEED
PMP-99413
RECYCLED WATER PUMP #3
75HP 480VAC 3PH
HSA
99413
LOR
HSC
99413
START
HSB
99413
STOP
HSS
99413
SPEED
PMP-99414
RECYCLED WATER PUMP #4
75HP 480VAC 3PH
HSA
99414
LOR
HSC
99414
START
HSB
99414
STOP
HSS
99414
SPEED
PI-99412

PRESSURE INDICATOR
0-150 PSI
PI
99412

PRESSURE
FE-99412

THERMAL FLOW SWITCH
450 GPM
FE
99412

THERMAL
FSL
99412
PI-99413

PRESSURE INDICATOR
0-150 PSI
PI
99413

PRESSURE
FE1-99413

THERMAL FLOW SWITCH
450 GPM
FE1
99413

THERMAL
FSL
99413
PI-99414

PRESSURE INDICATOR
0-150 PSI
PI
99414

PRESSURE
FE-99414

THERMAL FLOW SWITCH
450 GPM
FE
99414

THERMAL
FSL
99414
DISC
99412
DISC
99413
DISC
99414
MWH
99412
TSH
99412
LCP
99412
PMP
99412
MWH
99413
TSH
99413
LCP
99413
PMP
99413
MWH
99414
TSH
99414
LCP
99414
PMP
99414
16" RW 16" RW
16" RW
14" RW 14" RW 14" RW
1 06N01
1 06N01
TYP
*
NF111
TYP
*
NF111
TYP
*
NF111
CB
99412
TM
480VAC-3P

SWBD-RWPS
VFD
99412
EIP
PLC-99400
RECYCLED_PUMP
VFD
99413
EIP
PLC-99400
RECYCLED_PUMP
VFD
99414
EIP
PLC-99400
RECYCLED_PUMP
CB
99413
TM
480VAC-3P

SWBD-RWPS
CB
99414
TM
480VAC-3P

SWBD-RWPS
VFD-99412
VFD-RH
480VAC-3P

SWBD-RWPS
VFD-99413
VFD-RH
480VAC-3P

SWBD-RWPS
VFD-99414
VFD-RH
480VAC-3P

SWBD-RWPS
1 99N01
99N02

PUMP STATION

RECYCLED WATER
2 99N01
99N02

PUMP STATION

RECYCLED WATER
3 99N02
99N03

PUMP STATION

RECYCLED WATER
4 99N02
99N03

PUMP STATION

RECYCLED WATER
TYP
*
NP502
TYP
*
NP502
TYP
*
NP502
P
O
W
ER
SOURC
E
FIELD
I/O
P
lotD
ate: 06-APR
-2023
7:16:49
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
99N02
RECYCLED WATER PUMP STATION 2 P&ID
8660F1099N002.dwg
crollins
8660F10
169
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:48:47-06'00'
200

Page 408 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
PMP-99415
RECYCLED WATER PUMP #5
75HP 480VAC 3PH
1 06N01
HSA
99415
F LOR
HSC
99415

F START
HSB
99415
F STOP
HSS
99415

F SPEED
PE-99415

PRESSURE SWITCH LOW
75 PSIG OPEN
PI-99415

PRESSURE INDICATOR
0-150 PSIG
PI
99415
F
PE
99415

F PRESS SW
PSH
99415
F
FE-99415

THERMAL FLOW SWITCH
450 GPM
FE
99415

F THERMAL
FSL
99415
F
DISC
99415
F
4 99N02
99N03

PUMP STATION

RECYCLED WATER
3 99N02
99N03

PUMP STATION

RECYCLED WATER
MM
FE2-99431

FLOW METER
400-4000 GPM
16"
FE2
99431

MAGNETIC
FIT
99431
CB
99431
TM
120VAC-1P
PCM-99400
SYSTEM

DISTRIBUTION
MWH
99415
F
TSH
99415
F
LCP
99415
F
PMP
99415
F
F
99431
AI
PLC-99400
16" RW
TYP
*
NF130
NF136
PE-99432

PRESSURE TRANSMITTER
0-300 PSIG
PI-99432

PRESSURE INDICATOR
0-300 PSI
PI
99432

PRESSURE
PE
99432

PRESSURE
PIT
99432
TYP
*
NP501
P
99432
AI
PLC-99400
TNK
99432
VFD
99415
EIP
PLC-99400
F
RECYCLED_PUMP
CB
99415
TM
480VAC-3P

SWBD-RWPS
F
VFD-99415
VFD-RH
480VAC-3P

SWBD-RWPS
F
FUTURE
P
O
W
ER
SOURC
E
FIELD
I/O
16" RW
P
lotD
ate: 06-APR
-2023
7:16:58
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
99N03
RECYCLED WATER PUMP STATION 3 P&ID
8660F1099N003.dwg
crollins
8660F10
170
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:49:07-06'00'
200

Page 409 of 1800 ends

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 199

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
CP-99400
PLC-99400
PCM-99400

PCM CABINET

PCM-99400
CB2
99400
TM
120VAC-1P

PNL-RWPS-L
CB1
99400
TM
120VAC-1P

PNL-RWPS-L
SPD-99400

PCM SURGE PROTECTOR

TSH
99400
DI

PLC TEMP
PLC-99400
JS3
99400
DI

REDUNDANCY OK
PLC-99400
JS2
99400
DI

PWR SUP OK
PLC-99400
JS1
99400
DI

PWR SUP OK
PLC-99400
ZS1
99400
DI

INTRUSION
PLC-99400
XA6
99400
DI

SPD FAIL
PLC-99400
PCM
99400
SPD
99400
TSH
99400
ZS1
99400

INTRUSION DR
2 06N02
SPD2-99400

PCM SURGE PROTECTOR

XA4
99400
DI
SPD2 FAIL
PLC-99400
XA5
99400
DI

ES-P FAIL
PLC-99400
XA7
99400
DI

ECP-P FAIL
PLC-99400
SPD2
99400
XA5
99400
XA7
99400
JS4
99400
DI
ACB OK
PLC-99400
P
O
W
ER
SOURC
E
FIELD
I/O
PQM-99400

RECYCLED WATER PUMP STATION

PQM
99400
PQM
99400
EIP
PCM-9940
POWER_QUALITY_METER
P
lotD
ate: 06-APR
-2023
7:17:07
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1
PROJECT NO. FILE NAME:

DB
AAW
BAL

INSTRUMENTATION
99N04

RECYCLED WATER PUMP STATION
PCM-99400 CABINET P&ID
8660F1099N004.dwg
lbordelon
8660F10
171
Digitally signed by Brett A. Lee
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 16:49:29-06'00'
200

Page 410 of 1800 ends

3'-6"
1/2"
6"M
IN
1" MIN
1/2"
6"M
IN
1/2"
1/2"
1/2"
1/2"
8"
1"
5"
1 1/2"
1'-2"
6"
2"
2"
RUNG
S

EQUALLY SPAC
ED
@ 12"O
C
MAX
30" MAX
24" MIN

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405

3. PROVIDE CLOSURE FLANGE AT EXTERIOR WALL. SET FLANGE IN SEALANT.

3. LOCATE INVERT OF SCUPPER 2" ABOVE ADJACENT ROOF DRAIN INLET.

COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.

BE KYNAR. COLOR SHALL BE ENGINEER SELECTED FROM STANDARD COLOR OFFERINGS.

2. FABRICATE SCUPPER AND FLANGE FROM MIN 0.032" THICK PRE-FINISHED AL. FINISH SHALL OTHERWISE RECOMMENDED BY ROOFING MANUFACTURER.

1. PROVIDE SCUPPER AS DETAILED AND ADHERE TO SURROUNDING STRUCTURE UNLESS NOTES:

AC310
06/21/19
TYP
AC300
ROOF

IN MASONRY CONSTRUCTION

GROUT CELL AT ANCHORS
1/4
TYP
3"
8"
3"
8"
91/2"

SPACING

MAX WITH EQUAL
RUNGS @ 12" OC
*
*
TYP
WITH

EXCEPT AS NOTED

ALUMINUM LADDER
WATERTIGHT ROOF MEMBRANE.

SEAL ALL AROUND AND MAINTAIN
FLASHING AT LADDER SUPPORT.

RUNG
S

EQUALLY SPAC
ED
(12"O
C
MAX
)
NOTE 1
3"
(MASONRY SIMILAR.)
CONCRETE WALL.

TREAD PLATE)
AND 1" VERT EDGE ON
SURFACE TO T.O. COPING,
1" GAP (T.O. WALKING
SIDE 3/16
EA
TYP
2"

WELD AS NOTED

OVER LADDER RAIL AND
WITHOUT GATE. SLOT PIPE

ALUMINUM PIPE RAIL

PROVIDE SEMI-CIRCULAR
RAILS

AND WELD ENDS TO LADDER
PERIMETER EDGES DOWN 1"
3/8" AL TREAD PL. BEND 4

LADDER - ALUMINUM - PARAPET

3. INSTALL FALL PREVENTION SYSTEM WHERE HEIGHT OF LADDER EXCEEDS 24'-0".

TO CONCRETE WITH 1/2"Ø SST CONCRETE ANCHOR EACH SIDE. MIN 4" EMBED.

2. ABOVE CONCRETE SLAB, EXTEND RAILS DOWN. SET ON MIN 1" NON-SHRINK GROUT. FASTEN

1. WHERE NOT ABOVE CONCRETE SLAB, TERMINATE SIDE RAILS AS SHOWN.

NOTES:

METAL COPING AND

REGLET AND

COUNTERFLASHING

BASE FLASHING

WALL MATERIAL AS

INDICATED ON THE

DRAWINGS

SLOPE TOP OF WALL

PREFABRICATED

COUNTERFLASHING

REGLET &

BASE FLASHING

EXTEND BASE

FLASHING UP UNDER

COPING UNLESS

REGLET AND

COUNTERFLASHING

ARE INDICATED ON
THE DRAWINGS.

PREFABRICATED METAL

BASE FLASHING

ANCHOR PLATE

COPING AND ANCHOR
PLATE
06/21/19
TYP
AG220 PARAPET DETAILS
A
-
B
-
D
-
C
- METAL COPING

STUCCO FINISH PREFABRICATED

W/ REGLET

MASONRY WALL

W/ METAL COPING

CONCRETE WALL

W/ REGLET
~
~
~
8" MIN TO

TOP OF ROOF
8" MIN TO

TOP OF ROOF
8" MIN TO

TOP OF ROOF

TERMINATION BAR
1/2"
1/2"

TERMINATION BAR
@ 4'-0" OC
x 10" EMBEDMENT AB
3 x PRESSURE TREATED

TREATED TOP PLATE
DOUBLE 2 x PRESSURE

SCUPPER
PACK W/ NONFLANGE

CLOSURE

BUILT-UP
3" CANT
STRIP
ROOF

CLOSURE
FLANGE

SCUPPER

SINGLE PLY

SHRINK GROUT

SHRINK GROUT
PACK W/ NONCANT
STRIP

ROOFING
06/21/19
TYP
AG222
B
-

SECTION
DSECTION
E
-

CLOSURE
FLANGE
C
-

ISOMETRIC -

SINGLE PLY ROOFING
A
-

ISOMETRIC -

BUILT-UP ROOFING
E
-
E
-
51/2"

ASREQUIRED
11/2"
4"
10"
4"
4"
3"
4"
3"

ASREQUIRED
51/2"
4"
10"
4"
4"
11/2"
4"
1"
11/2"(TYP)

SCUPPER - SECONDARY

BUILT-UP AND SINGLE-PLY SYSTEMS
06/21/19
AG223
TYP
E
-

CLOSURE
FLANGE
C
-

ISOMETRIC -

SINGLE PLY ROOFING
D
-

SECTION
A
-

ISOMETRIC -

BUILT-UP ROOFING
B
-

SECTION
E
-
E
-

ASREQUIRED
51/2"
4"
10"
4"
4"
3"
3"
4"

ASREQUIRED
51/2"
4"
10"
4"
4"
1"
11/2"(TYP)

SCUPPER

CLOSURE
FLANGE
PACK W/ NONSHRINK GROUT SINGLE PLY
ROOF

SCUPPER
FLANGE

CLOSURE

SHRINK GROUT
PACK W/ NONBUILT-UP

ROOFING
3" CANT
STRIP
CANT
STRIP

3. PROVIDE CLOSURE FLANGE AT EXTERIOR WALL. SET FLANGE IN SEALANT.

COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.

BE KYNAR. COLOR SHALL BE ENGINEER SELECTED FROM STANDARD COLOR OFFERINGS.

2. FABRICATE SCUPPER AND FLANGE FROM MIN 0.032" THICK PRE-FINISHED AL. FINISH SHALL OTHERWISE RECOMMENDED BY ROOFING MANUFACTURER.

1. PROVIDE SCUPPER AS DETAILED AND ADHERE TO SURROUNDING STRUCTURE UNLESS NOTES:

SCUPPER - PRIMARY

BUILT-UP AND SINGLE-PLY SYSTEMS

DRAWINGS
ON THE

INDICATED

WALL AS

ROOF DRAIN

SCUPPER

DOWNSPOUT

CONDUCTOR
HEAD
06/21/19
TYP
AG225
A
-
B
-

ELEVATION SECTION
B
-
WITH ROOFING TYPE.

3. SEE SPEC FOR SPECIFIC ROOFING AND INSULATION MATERIAL. SCUPPER SHAPE WILL VARY AL IN CONTACT WITH CONC OR CMU AS SPECIFIED. SEAL ALL JOINTS.

KYNAR. COLOR SHALL BE ENGINEER SELECTED FROM STANDARD COLOR OFFERINGS. COAT

2. FABRICATE CONDUCTOR HEAD FROM MIN 0.032" THICK PRE-FINISHED AL. FINISH SHALL BE MANUFACTURER.

1. PROVIDE CONDUCTOR HEAD AS DETAILED UNLESS OTHERWISE RECOMMENDED BY ROOFING NOTES:

CONDUCTOR HEAD - ALUMINUM

DOWNSPOUT HANGER
1 1/2" x 0.062 AL
@ 4'-0" OC
CONC ANCHORS @

INDICATED ON THE

WALL MATERIAL AS

CONC OR MASONRY

WALLS (TYP)

SPLASH BLOCK

WHERE REQD
3" x 4" DOWNSPOUT
FORMED FROM 0.032
06/21/19
TYP
AG227
A
-
A
-

SECTION

DRAWINGS

PRE-FINISHED AL UNLESS

OTHERWISE INDICATED
ON THE DRAWINGS.

SELECTED FROM STANDARD
COLOR OFFERINGS.

COLOR SHALL BE ENGINEER

3. COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.

2. ALTERNATE SIZE DOWNSPOUTS WILL BE REQUIRED, IF SO INDICATED ON THE DRAWINGS.

1. PROVIDE SPLASH BLOCK AS SHOWN EXCEPT AT PAVING AND SIDEWALKS.

NOTE:

DOWN SPOUT - ALUMINUM
2 - 1/4"Ø SST
4" FELT CAP FLASHING. SET IN

FLASHING CEMENT AND COVER
W/ 1/8" THICK FLASHING CEMENT.

BASE FLASHING

SET IN ASPHALT

BACKER FELT

SET IN ASPHALT

ROOFING FELTS
3" CANT STRIP

TAPERED INSULATION ROOF CRICKET

WHERE INDICATED ON THE DRAWINGS
RIGID INSULATION.

THICKNESS AS SPECIFIED.

SEE DRAWINGS FOR ROOF

DECK AND ROOF FRAMING

SCREW TYPE

SIZE AND SPACING

PER MANUFACTURERS
RECOMMENDATION.

MECH FASTENERS.

WALL MATERIAL AS INDICATED
08/01/05
TYP
AG140
~
~
~
~
~
~
~
~
~
5"M
IN
3"

ON THE DRAWINGS
TYP
AG220 METAL COPING

THE DRAWINGS

AS INDICATED ON

COUNTERFLASHING

OR REGLET AND

ROOF SYSTEM - BUILT-UP - DETAIL
TYP
AG227
TYP
AG223
TYP
AG229
TYP
AC300
S 12/28/20
A
-

SECTION

WELDING (TYP)

GRIND SMOOTH AFTER

RADIUS OF GUARDRAIL POST,

BEND BAR SIDE RAILS TO

LANDING LEVEL

TOP RUNG AT
1/2" RADIUS

SIDE RAILS
1/2 x 4

AL RECT
1/8" RADIUS

SMOOTH TO

CORNERS

ROUND ALL
1/4
TYP
1/4
1/4
1'-4"
8"
4"
TYP
AN
CHO
R
S
TR
APS.

SPAC
E
@
6'-0"O
C
MAX.
1'-6"
3'-6"

OTHERWISE INDICATED)

GATE (TYP UNLESS

ELEVATION
RAILS AND PLUG WELD. (TYP)

EXTEND HALF WAY THROUGH
TREAD ON TOP SURFACE.

AL 1" SQ SOLID RUNGS W/

DRAWINGS

INDICATED IN THE

GUARDRAIL, TYPE AS
GROUT
MINIMUM 1" NON-SHRINK
DWGS

WALL, SEE

MASONRY

CONC OR

LADDER - ALUMINUM - WALL
MASONRY CONSTRUCTION. (TYP)

ANCHOR INTO GROUTED CELL AT
WALL W/ 5/8"Ø SST CONC ANCHORS.

WELD TO LADDER AND FASTEN TO
AL RECT 3/8 x 3 ANCHOR STRAP.
5/8"Ø SST CONC ANCHORS

FASTEN TO FLOOR W/

4. WHERE GUARDRAIL IS SST, BOLT PIPE TO RAIL W/ 2 - 1/2"Ø SST BOLTS.

SLEEVES AND WASHERS AT DISSIMILAR METALS, AS SPECIFIED.

3. COAT ALL AL SURFACES IN CONTACT W/ CONC AND MASONRY, AND INSTALL ISOLATION (2'-3" AT SMOOTH WALL). 1'-3" EACH SIDE OF CENTER LINE, ON EACH SIDE OF LADDER.

2. MINIMUM CLEARANCE TO ANY OBSTRUCTION ADJACENT TO LADDER: 2'-6" ON CLIMBING SIDE

1. INSTALL FALL PREVENTION SYSTEM PER SPEC WHERE HEIGHT OF LADDER EXCEEDS 24'-0".

NOTES:
-
A
P
lotD
ate: 06-APR
-2023 12:33:25
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE
CE

TYPICALS

TYPICAL DETAILS
8660F10
eparker
00TA01
8660F1000TA01.dgn

ARCHITECTURAL
JKN
172
Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 17:00:25-04'00'

Page 411 of 1800 ends

WIDTH
FRAME
3'-0"
FR
AM
E
H
E
IGH
T
4"
2"
5'-0
6" TYP "
3'-8"
MAX
3'-0"
6" 2"
5 3/4"
5'-0"MAX5'-0"MAX

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 84405
~
AJ100
06/21/19
TYP

REMOVABLE TRANSOM BAR

GLASS SIDELIGHT
R S
T
~
~
LOCATIONS REQUIRED. (TYP)

HARDWARE SCHEDULE FOR
FRAME TYPE. SEE DOOR AND
BE TINTED INSULATING GLASS.

4. GLASS AT INTERIOR SIDELIGHTS SHALL BE CLEAR. GLASS AT EXTERIOR SIDELIGHTS SHALL

3. GLASS AT SIDELIGHTS SHALL BE TEMPERED.

LOCATION.

2. SIDELIGHT MAY BE ON EITHER SIDE OF DOOR. SEE DRAWINGS FOR REQUIRED SIDELIGHT

1. SEE DOOR AND HARDWARE SCHEDULE FOR FRAME SIZE, MATERIAL, AND DETAILS.

NOTES:
(TYP)
DOOR - FRAME - STICK AJ103
06/21/19
TYP

PANEL ONLY

TRANSOM

REMOVABLE

COILING METAL DOOR

F G N V D
A
C T
(TYP)
6"
6" MIN
6"
6"
10" SQ
10"
10"
2"
~
~
~
~
~
~
~
GLASS
GLASS
GLASS
GLASS
SHELF

DOOR WITH
DUTCH
LOCATIONS REQUIRED. (TYP)

HARDWARE SCHEDULE FOR
DOOR TYPE. SEE DOOR AND

ALUM FRAME
~
NOTE 5
SEE
LOUVER.

SCHEDULE.

AND HARDWARE

NOTED ON DOOR

TRANSOM AS

DOOR TYPE BELOW
NOTES:

1. DOOR SIZE AND TYPE SHALL BE IN ACCORDANCE WITH DOOR AND HARDWARE SCHEDULE.

2. GLASS AT DOORS SHALL BE TEMPERED UNLESS OTHERWISE INDICATED ON THE DRAWINGS.

3. GLASS AT INTERIOR DOORS SHALL BE CLEAR. GLASS AT EXTERIOR DOORS SHALL BE TINTED.

4. PROVIDE WIRE GLASS AT LABELED DOORS.

5. LOUVER MAY BE REQD AT ANY DOOR TYPE. IF A LOUVER IS REQUIRED, SIZES AND LOCATIONS WILL BE NOTED ON DOOR AND HARDWARE SCHEDULE.

6. PROVIDE LABELED DOORS IN ACCORDANCE WITH DOOR AND HARDWARE SCHEDULE.

DOOR - ELEVATIONS - TYPES
A
-

METAL FRAMING B
-

WOOD FRAMING
C
-
D
-

MASONRY CONCRETE
AJ105
06/21/19
TYP
3/4"
3/4"
1/2" MIN
~
~

CAULK BOTH SIDES

FILL WITH GROUT

CAULK BOTH SIDES

FILL WITH GROUT
HEADER. 2 - 2x MIN.

DOOR FRAME DOOR FRAME

DOOR FRAME

DOOR FRAME
WALL

THICKER

LINE OF
DOOR
DOOR
TO JAMB.

DOWN AND FASTEN

CLIP LEGS, BEND
METAL TRACK.

SHEET 1 OF 2

GYPSUM BOARD GYPSUM BOARD

DOOR - HEAD - DETAILS
A
-
B
-
C
-

MASONRY

METAL FRAMING WOOD FRAMING
AJ107
06/21/19
TYP

GYPSUM BOARD GYPSUM BOARD

JAMB ANCHOR

PER JAMB

TWO STUDS

CAULK BOTH SIDES
~
~
SHEET 1 OF 2
5/8"
1 15/16"
5/8"
1 15/16"
3/4"
5/8"
1 15/16"
~~

FILL WITH GROUT

DOOR FRAME

DOOR FRAME
(TYP)
DOOR

DOOR FRAME
D
-

CONCRETE

PIPE SPACER

CAULK BOTH SIDES
~

FILL WITH GROUT

LINE OF THICKER WALL
3/4"
1 15/16"
5/8"

DOOR FRAME
DOOR
ANCHOR
(

COUNTERSUNK
NOTE
2)

LINE OF THICKER WALL

DOOR - JAMB - DETAILS
A
-
B
-
C
-
D
-
E
-
AJ109
06/21/19
TYP

CARPET BAR

RESILIENT
CARPET

STRIP AS REQ'D

RESILIENT REDUCER

CONCRETE CERAMIC TILE
PAD AT EXTERIOR.

CONC SIDEWALK OR ENTRANCE
CONT CONC SLAB AT INTERIOR.

WITH ROOM FINISH SCHEDULE

FINISH FLOOR MATERIAL IN ACCORDANCE

FINISH SCHEDULE

WITH ROOM

IN ACCORDANCE

OR SHEET VINYL

RESILIENT TILE

ROOM FINISH SCHEDULE

IN ACCORDANCE WITH

FINISH FLOOR MATERIAL

SCHEDULE
FINISH

WITH ROOM

ACCORDANCE

MATERIAL IN

FINISH FLOOR

CONTINUOUS

1. DOOR CLEARANCE AT BOTTOM OF DOOR SHALL BE 1/4" MIN AND 3/8" MAX.

NOTE:

SET THRESHOLD IN SEALANT.

HARDWARE SCHEDULE.

ACCORDANCE WITH DOOR AND

THRESHOLD AND DOOR BOTTOM IN

DOOR - SILL - DETAILS
2"
2"
2"
1"
1'-2"
4"
2'-0"
51/2"
2"
4"
06/21/19
AG229
TYP
2"
2"
2"
1"
1'-2"
4"
2'-0"
51/2"
2"
4"

SPLASH BLOCK - CONCRETE - SURFACE MOUNTED
FIRE EXTINGUISHER.

SEE SPECIFICATIONS
FOR SIZE AND TYPE.

FINISH FLOOR

ELEVATION
WALL
FIRE EXTINGUISHER.

SEE SPECIFICATIONS
FOR SIZE AND TYPE.

FINISH FLOOR

ELEVATION
WALL

2. SEE SPECIFICATIONS FOR SIGNAGE REQUIREMENTS ABOVE FIRE EXTINGUISHERS.

PARTITION WALL.

GROUTED CELL. MOUNT TO STUD WITH LAG BOLTS, OR WOOD SCREWS FOR WOOD CONCRETE ANCHORS FOR MASONRY OR CONCRETE WALLS. AT MASONRY INSTALL AT

1. MOUNT TO WALL WITH NUMBER AND SIZE OF ANCHORS TO MATCH BRACKET. USE NOTES:

AN400
TYP
06/21/19

FIRE EXTINGUISHER

WALL-MOUNTED
P
lotD
ate: 06-APR
-2023 12:33:09
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE
CE

TYPICALS

TYPICAL DETAILS
8660F10
eparker
00TA02
8660F1000TA02.dgn

ARCHITECTURAL
JKN
173
Digitally signed by Matthew C. Kallevant
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 17:01:01-04'00'

Page 412 of 1800 ends

OD OF MANHOLE + 12"
10"
3" MIN
3'-6"
1"
1"
SEE DRAWINGS (4'-0" MIN)

PAD LENGTH
SEE
D
R
AW
ING
S
(6'-0"M
IN
)
PAD
W
ID
TH
M
IN
1'-4"
M
IN
12"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 76832

SEE DWGS
FIN FL
(TYP)
1/4" RADIUS

JOINT SEALANT

SIDEWALK/PAVEMENT
1/4" MIN
"W" /2
GAP
MAX 3/8"
MIN 1/4"

BACKER ROD

JOINT MATERIAL

RUBBER EXPANSION

SYNTHETIC SPONGE

CUT OUT TOP OF RCP

OR VCP WITHIN MANHOLE
3" EPOXY GROUT
SEE NOTE 2 (TYP)
CLASS "A"
48" FOR 6" THRU 12"
PIPES.
60" FOR 15" THRU 48"
PIPES.
#5 @ 12" EW

STEEL TROWEL
FINISH

SOIL BACKFILL

EXISTING PAVEMENT

TOP OF MH SHALL MATCH

AC PAVEMENT OR

CONCRETE

INDICATED ON THE

UNLESS OTHERWISE
MORTAR
6" TO EXISTING GRADE

DRAWINGS

BASE WHERE SOIL IS
OR 8" MIN ABC UNDER

UNDISTURBED SOIL

CAST BASE AGAINST
UNSTABLE.

CAST-IN-PLACE
CONE SHOWN ROTATED 90°.

TYP
N
8" (TYP)
12" MIN
6" MIN. 1'-6" MAX.
6" CLR
CS110 MANHOLE
30" CI MH FRAME AND COVER.
~
3" MIN
A
S
R
EQD
CLASS "A" CONCRETE BASE.

PRECAST CONCRETE MANHOLE

ECCENTRIC PRECAST CONCRETE

GRADE RINGS AS REQUIRED
2'-6"TO
3'-0"

RISERS WITH VARIABLE HEIGHT
MANUFACTURER'S DETAIL.

3. FORM GROOVE IN MANHOLE BASE WITH STEEL OR ALUMINUM BASERING PER

2. SEAL JOINTS WITH PRECAST CONCRETE JOINT SEALANT.

GROUT.

1. LOCATE MANHOLE COVER ON DOWNSTREAM SIDE OF MANHOLE. SET MANHOLE FRAME IN NOTES:

SEE NOTE 3
SEE NOTE 1.
12/24/2020

SEE DWGS
FINISHED GRADE.

PAVEMENT OR
(7" MAX)

ON DWGS
SHOWN

OTHERWISE
4" UNLESS

PVC PIPE SLEEVE
CLASS "C" CONCRETE
4"Ø GALV SCH 40 STEEL POST.
4'-0"
6"

MATERIAL ALL

CONCRETE PAVEMENT
SEE DRAWINGS.

CONCRETE PAVEMENT

WELD ON CAP

PAINT SAFETY YELLOW PER
ANSI Z535.1. 1/2" BITUMINOUS

FIBER EXP JOINT

AROUND (UNLESS

OTHERWISE INDICATED

ON THE DRAWINGS)

FINISHED GRADE

AC PAVEMENT OR

FINISHED GRADE
OR AC PAVEMENT.

TYP
N
CF161
-
B
-
B
-
A
12/29/2020

GUARD POST - REMOVABLE
1/4" RADIUS
CR314
TYP
-

SECTION
-
~
TYP

EACH SIDE
#4@12" EW
#4 x

FIN FL UNO

FLUSH W/
T.O. PAD

SIDEWALK - ENTRANCE PAD

OF DOOR
SLOPE
1/4"/FTUNO
(TYP 3 SIDES)

THICKENED EDGE
B
A
PLAN
B
(TYP ALL EDGES)
6" 8"

MIN (TYP)

EXT DOOR

THRESHOLD
SEE NOTE 1.

EXPANSION JOINT.

EMBED.

S194/TYP MIN 4"

SET PER DETAIL
SMOOTH DOWELS.
304 SST OILED
1/2" DIA x 1'-8TYPE

ABC (TYP)

COMPACTED
MIN 6"

1. EXPANSION JOINT AT FACE OF STRUCTURE: 3/8" WIDE AND AS INDICATED IN DETAIL 1.

NOTES:
-
1 DETAIL
12/24/2020
CR314
TYP

SIDEWALK - ENTRANCE PAD
12/24/2020

AT CONC

PAVEMENT
6" 0"
3" CLR
MIN
MIN
2"CLR
P
lotD
ate: 06-APR
-2023 11:13:23
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE
CE

TYPICALS

TYPICAL DETAILS
8660F10
00TC01
eparker
CIVIL
8660F1000TC01.dgn
JM
174
Digitally signed by Brian W. Avon
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.10 09:21:31-07'00'

Page 413 of 1800 ends

6"M
IN 12" 12"

PREFORMED CHANNEL
WALLS AND LINTELS.

DRAWINGS FOR REINFORCEMENT IN
CMU WALL. REFER TO STRUCTURAL
(TYP)
WEIGHTS UNDER 200 LBS. U.O.N.
5/8" Ø WITH 3" OF EMBEDMENT FOR

Z FITTING W/ CMU ANCHOR FOR CMU,

AS REQUIRED (TYP)

ANCHORS, NUTS, AND LOCKWASHER
FITTINGS AT 2'-8" O.C. MAX

PROVIDE INTERMEDIATE Z
WHERE LENGTH EXCEEDS 2'-8"
18"

DECK - SEE STRUCTURAL

CROSSING)
(TYP EACH SIDE EACH BEAM

BEAM CLAMP W/SQ U-BOLT

PREFORMED CHANNEL

STEEL BEAM
3/4" RIGID CONDUIT

GUSSET FOR LUMINAIRE

BEAM CLAMP WITH
(SIDE VIEW)

STEEL BEAM

CONDUIT HANGER

BEAM CLAMP WITH
6" MIN 6" MIN

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

GROUND ROD

TYP COMPRESSION CONNECTION
EG002
S

DIAMETER AS SPECIFIED)

GROUND ROD (LENGTH AND
GRADE

FINISHED
1 1
KEY NOTES:

CABLE PER CONNECTOR MANUFACTURERS GUIDELINES.

GROUND ROD TO GROUND GRID CROSS CONNECTOR. SIZE FOR ROD AND OR IN SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
3'-0" (MIN) SOIL

FINISHED GRADE

DIAMETER AS SPECIFIED)

GROUND ROD (LENGTH AND

BACKFILL
SOIL
1 1
KEY NOTES:

DRAIN ROCK
OR IN SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS

GROUND GRID CONDUCTOR
AND CABLE PER CONNECTOR MANUFACTURERS GUIDELINES.

GROUND ROD TO GROUND GRID CROSS CONNECTOR. SIZE FOR ROD

GROUND WELL AS SPECIFIED
EG001 GROUND ROD AND GROUNDWELL

TYP COMPRESSION CONNECTION
S
GENERAL NOTES:

CONCRETE ANCHORS SHALL BE PER THE SPECIFICATIONS.

2. SUPPORTS TO BE SPACED IN ACCORDANCE WITH NEC REQUIREMENTS.

1. THIS DETAIL TYPICAL FOR BOTH VERTICAL AND HORIZONTAL MOUNTING.

GRADE

FINISHED
1 1
OR IN SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
3'-0" (MIN)
SOIL
MANUFACTURERS GUIDELINES.

GROUND GRID CROSS CONNECTOR. SIZE FOR CABLE PER CONNECTOR KEY NOTES:

EG101
TYP
S

COMPRESSION CONNECTION

COPPER GROUNDING CABLE CONNECTION
SKID

GROUND BUS OR EQUIPMENT

CONNECT TO EQUIPMENT

HOUSEKEEPING PAD

FLOOR OR

GROUNDING PLATE
KEY NOTES:
1 1
PLACEMENT OF CONCRETE.

INTO GROUND PLATE PRIOR TO

THREAD A POSITIONING ROD
SPECIFICATIONS.

DRAWINGS OR IN

SIZE AS INDICATED ON THE
GROUND GRID CONDUCTOR.

SPECIFICATIONS.

DRAWINGS OR IN

SIZE AS INDICATED ON THE
GROUND GRID CONDUCTOR.

EG102
TYP
S

COMPRESSION CONNECTION

CAST GROUNDING PLATE

DUXSEAL

FILL WITH
GRADE

FLOOR SLAB OR
COLUMN, ETC.

SKID, POST, STEEL BLDG.

METALLIC EQUIPMENT

CLAMP TO SKID
1-1/2" MINERALLAC
HEAVY DUTY COMPRESSION TERMINAL.

KEY NOTES:
1 1
NOTES:

SLEEVE
SCHEDULE 80
1-1/2" PVC
SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS OR IN
GROUND GRID CONDUCTOR.

STRUCTURE, NOT TO EQUIPMENT OR TANK SHELLS.

2. NOTE: BOLT GROUND LUG ONLY TO EQUIPMENT SKIDS OR
BOLTING ON THE GROUND LUG.

1. CLEAN ALL PAINTED SURFACES TO BARE METAL BEFORE
EG201 EQUIPMENT SKID GROUNDING

TYP COMPRESSION CONNECTION
S
A
S
R
EQU
IR
ED

PREFORMED CHANNEL ATTACHMENT

TO FULLY GROUTED CMU WALL
EA080
TYP
S
TYP
S
EA060

GRATING SUPPORTS

ATTACHMENT TO ALUMINUM
3/16 1/2
3/16 1/2
4" MAX
2" MIN
FLANGE
BEAM

EDGE OF
FLANGE

PL TO BEAM

TYP EA CLAMP
ACROSS
ALONG

ATTACHMENT TO STEEL BEAMS
S
TYP
EA030

AL CHANNEL

PREFORMED

CHANNEL

SUPPORT

AL GRATING

CHANNEL

SUPPORT

AL GRATING

CLAMP (TYP EA END)

STEEL U-BOLT W/TOP

SQUARE STAINLESS

AL GRATING
P
lotD
ate: 06-APR
-2023 11:14:46
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE01
175
8660F1000TE01.dgn

ELECTRICAL
eparker
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:44:17-07'00'

Page 414 of 1800 ends

GROUT

NON-SHRINK
REQUIREMENTS.

POLE MANUFACTURERS

LEVELING NUTS PER

LOCK WASHERS, AND

SST ANCHOR BOLTS, NUTS,
REQUIREMENTS.

NUTS PER POLE MANUFACTURERS

LOCK WASHERS, AND LEVELING

SST ANCHOR BOLTS, NUTS,
WALL

OR SPECIFICATIONS)
(SIZE AS INDICATED ON DRAWINGS

GROUND GRID CONDUCTOR

FOOTING
CONCRETE.
20'-0" LENGTH ENCASED IN
#4 SDBC (MIN) WITH MIN

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
GROUT

NON-SHRINK
BACK
BOLT
PANEL
WASHER
& USE A STAR

SCRAPE PAINT

GROUND CONNECTION

THREADS TO ALLOW A

REMOVE PAINT FROM

USE A WIRE BRUSH TO

THE ENCLOSURE

BACK WALL OF

PANEL TO THE

OF THE BACK

STUD MOUNTING

BACK PANEL

CHASSIS TO THE

BUS OR A

OF A GROUND

BOLT MOUNTING
WASHER
FLAT
HOLE
TAPPED
STUD
WELDED
(TYP)

BRACKET

MOUNTING

GROUND BUS OR

BACK PANEL

CHASSIS TO THE

BUS OR A

OF A GROUND

STUD MOUNTING
(TYP)
WASHER
STAR
STUD
WELDED
PAINT
SCRAPE

ENCLOSURE

BACK WALL OF
BOLT
(TYP)

GROUND LUG

COMPRESSION
(INSIDE) (OUTSIDE)

ENCLOSURE WALL

CONDUCTOR (TYP)

GROUNDING

EQUIPMENT
WALL

ENCLOSURE

CHASSIS TO

BUS OR A

OF A GROUND

BOLT MOUNTING
(TYP)
NUT
OR
TYP
S
EG205 ENCLOSURE GROUNDING DETAILS

C PHASE

B PHASE

A PHASE

TRANSFORMER

FIRST DISCONNECTING DEVICE AFTER

EQUIPMENT FRAME

INTEGRALLY BONDED TO

EQUIPMENT GROUND BUS

EQUIPMENT FRAME

GROUND PAD

TRANSFORMER

CONDUCTOR

GROUNDING ELECTRODE

TYPE BUSHINGS

GROUNDING

CONDUIT

NEUTRAL BUS

SYSTEM BONDING JUMPER

DRAWINGS

SYSTEM AS INDICATED ON THE

TO GROUNDING ELECTRODE

DRAWINGS

SYSTEM AS INDICATED ON THE

TO GROUNDING ELECTRODE

EQUIPMENT BONDING JUMPER
TYP
S
EG511 TRANSFORMER (NON-UTILITY) 3-PHASE, 4-WIRE

SECONDARY POWER GROUNDING DETAIL

CONDUIT

FLUSH MOUNTED

SUSPENDED

CONDUIT

LUMINAIRE

LUMINAIRE
HANGER

CONDUIT
HANGER

CONDUIT

STRAP OR EQUAL
HANGER w/SAFETY

APPLETON FHSN

OR EQUAL

FHLF LOOP

APPLETON

OR EQUAL

AHG HANGER

APPLETON
KEY NOTES:

USE MEYERS HUB IN WET AND/OR CORROSIVE AREAS.

LENGTH AS REQUIRED FOR INDICATED MOUNTING HEIGHT.

TO ATTACHMENT DETAIL

PREFORMED CHANNEL REFER
CAP END CONDUIT AS REQUIRED.

AS REQUIRED (TYP)

STUD NUT OR HANGER

LINEAR FIXTURE NUT,

TO ATTACHMENT DETAIL

PREFORMED CHANNEL REFER
ROD

CHAIN OR
1 2 2
3 TYP
S
EL200
1 2
3 LINEAR LUMINAIRE MOUNTING
TYP

ONE-PIECE POLE

HINGED POLE
TYP
S
EL502 ANCHOR BASE FOR LIGHT POLE

MOUNTED ON SLAB
TYP
S
EG304 GROUNDING CONNECTION TO

FOOTING (UFER)
1 1

GROUND BUS MOUNTING

GROUND BUS
BOLT
WASHER
STAR
HOLE
TAPPED
BUS
GROUND

GROUND LUG

ELECTRODE SYSTEM

CONDUCTOR TO GROUNDING

GROUNDING ELECTRODE

CONDUCTORS

GROUNDING

EQUIPMENT

ELEVATION VIEW SIDE VIEW

GROUND LUG

COMPRESSION
TYP
S
EG204 GROUND BUS CONNECTIONS
# KEY NOTES:

BETWEEN CONDUCTOR AND FACE OF CONCRETE.

PROVIDE MIN 1 1/2" CLEAR BETWEEN CONDUCTOR & REINFORCEMENT, OR

1. GROUND GRID CONDUCTOR TO BE FULLY ENCASED IN CONCRETE.

P
lotD
ate: 06-APR
-2023 11:13:29
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE02
176
8660F1000TE02.dgn

ELECTRICAL
eparker
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:45:02-07'00'

Page 415 of 1800 ends

(TYP
)

3.0"
(TYP)

3.0"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
5 4
3 2
1 GROUND WIRE
SDBC

CONCRETE (RED)

CLASS CE

FINISHED GRADE
12"
24"
BELOW
GRADE (MIN)"
CURING.

3. MAKE PROVISIONS TO PREVENT CONDUIT FLOTATION DURING CONCRETE PLACEMENT & CONDUITS.

REFER TO DUCT BANK SECTIONS, AND CONDUIT SCHEDULE FOR NUMBER AND SIZE OF SPECIFICATION TO ACCOMMODATE ACTUAL NUMBER OF CONDUITS WITHIN DUCT BANK.

2. ADJUST SIZE OF DUCT BANK BASED UPON THESE GUIDELINES AND THE DUCT BANK

1. DIMENSIONS SHOWN ARE MINIMUM.

NOTES:
6 7
8 OTHERWISE INDICATED ON THE DRAWINGS.
#4/0 SDBC GROUND WIRE UNLESS
THE DUCT BANK.

BOND THE DUCT BANK GROUND WIRE TO THE GROUNDING SYSTEM AT BOTH ENDS OF VERTICAL LEGS EACH SIDE.

LOWER PORTION OF TIES COULD BE U-BARS IF UPPER PORTIONS PROVIDES 1'-4" CONTRACTOR'S OPTION TO PROVIDE 1'-4" LAP LENGTH EACH SIDE OF HORIZONTAL TIE. 1'-4" OR 135 DEGREE HOOK FOR SHALLOW DUCT BANKS SHALLOWER THAN 21" REFER TO DUCT BANK SECTIONS AND SPECIFICATIONS FOR CONDUIT REQUIREMENTS.

PVC CONDUIT SPACERS ON 8'-0" CENTERS (MAXIMUM). LOCATE 12" FROM TIES.

SUPPORTS AT INTERVALS OF 24" TO REDUCE DEFLECTION.

PVC CONDUIT SPACER ALONG LENGTH OF DUCT BANK. PROVIDE PRECAST BAR

MINIMUM OF TWO PRECAST CONCRETE BAR SUPPORTS PLACED UNDER A TIE AT EACH #4 REINFORCING STEEL TIES MAXIMUM 24" ON CENTER ALONG LENGTH OF DUCT BANK.

BANK.
#4 REINFORCING STEEL 12" MAXIMUM ON CENTER AROUND ENTIRE PERIMETER OF DUCT KEY NOTES:
9 S
EM001 REINFORCED CONCRETE DUCT BANK
1 4
2 3
2 4
5 TYP
1 6
6 6 7
8 2
3 9
5 TYP
S
EL506
-
- B SECTION

A SECTION
A
-
-
B
S101

TRAFFIC AREAS

POLE FOUNDATION

1. SEE NOTE
6-#5 MIN.

LAP SPLICE @ TOP SPIRAL.
#3 SPIRAL MIN. SEE NOTE 1.
3"CLR

POLE BASE

CONC PIER
POLE
4"
MIN
LBOLT
ANCHOR
C

CONDUIT
GRADE

ELEVATION

COMPACTED SOIL

CONCRETE
CLASS "A" SEE

LAP SPLICE

FINISHED

CONDUIT(S)

ELECTRICAL

ENCASED
SEE NOTE 1.
5'-0"M
IN
P
ITC
H
3 @
3"
2"C
LR
P
ITC
H
O
F
SP
IR
AL
MIN
8"
3"C
LR
GROUT
MIN 1" NON-SHRINK
POLE
COVER

POLE BASE
TYP

PER POLE MFR REQUIREMENTS

WASHERS, AND LEVELING NUTS

SST ANCHOR BOLTS, NUTS, LOCK
6"P
ITC
H
2'-0"M
IN
3'-0"
SEE NOTE 1
2'-0"D
IA
M
IN
SEE NOTE 1
2'-0"D
IA
M
IN
INCREASE DIMENSIONS AND INCREASE DIMENSIONS AS REQUIRED.

OTHERWISE NOTED. PROVIDE WIND LOAD CALCULATIONS AND

1. USE MINIMUM DIMENSIONS AND REINFORCEMENT SHOWN UNLESS GENERAL NOTES: GENERAL NOTES:

TYP
S
EL507
POLE

CONDUIT
GRADE

SST ANCHOR BOLTS,

NUTS, LOCK WASHERS,

AND LEVELING NUTS PER

ELEVATION

COMPACTED SOIL

CONCRETE
CLASS "A"
SEE

LAP SPLICE

POLE BASE

CONC PIER
L
POLE

FINISHED
COVER

POLE BASE

CONDUIT(S)

ELECTRICAL

ENCASED
GROUT
MIN 1" NON-SHRINK

1. SEE NOTE
6-#5 MIN.

LAP SPLICE @ TOP SPIRAL.
#3 SPIRAL MIN. SEE NOTE 1.

TYP
S101
SEE NOTE 1.
5'-0"M
IN
6"P
ITC
H
P
ITC
H
3 @
3"
2"C
LR
A
-
-
B
-
B
-

A SECTION SECTION
P
ITC
H
O
F
SP
IR
AL
4"
MIN
2'-0"M
IN
3"CL
B
R
OLT
ANCHOR
C
MIN
8"
3"C
LR

NON-TRAFFIC AREAS

POLE FOUNDATION
2'-0"D
IA
M
IN
SEE NOTE 1
SEE NOTE 1
2'-0"D
IA
M
IN
INCREASE DIMENSIONS AS REQUIRED.

OTHERWISE NOTED. PROVIDE WIND LOAD CALCULATIONS AND

1. USE MINIMUM DIMENSIONS AND REINFORCEMENT SHOWN UNLESS

POLE MFR REQUIREMENTS
P
lotD
ate: 06-APR
-2023 11:15:43
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE03
177
8660F1000TE03.dgn

ELECTRICAL
eparker
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:44:49-07'00'

Page 416 of 1800 ends

3" (TYP)
3"
4"
2'-6"
12"
(TYP
)"
18"
2"
3"
2" 3"
1"

ENVELOPE

CONCRETE

CONDUIT REINFORCING STEEL
(TYP)

BAR SUPPORT

PRECAST CONCRETE
ON THE DRAWINGS.

UNLESS OTHERWISE INDICATED
# 4/0 SDBC GROUND WIRE MIN.

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
#4@12"
#4 U-SHAPED BARS

LAP SPLICE
(TYP)
TYP
TYP
3" CLR COVER
DRAWINGS.

ON THE

AS INDICATED

DUCT BANK

CONTINUING
GENERAL NOTES:

KEY NOTES:

1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS.

EQUIPMENT ABOVE.

ADJUST DUCT SPACING TO FIT OPENING IN THE SLAB AND
TYP
S
EM020 DUCT BANK RISER
1 EM001
EM001
1 FINISHED GRADE

BACKFILL

WARNING TAPE

SAND BACKFILL

CONDUIT OR CABLE

DIRECT BURIED

2. REFER TO THE SPECIFICATIONS FOR TRENCH BACKFILL REQUIREMENTS.

DRAWINGS.

1. ALL DIMENSIONS ARE MINIMUM UNLESS OTHERWISE INDICATED ON THE NOTES:

TYP
S
EM015 DIRECT BURIED CONDUIT OR CABLE
KEY NOTES:

PVC COATED RIGID

STEEL CONDUIT
#4@12"

STD HOOK

CONDUCTOR

ELECTRODE

GROUNDING
GRADE

SLAB ON

CONDUIT
PVC
CONDUIT IS NOT PROTECTED BY AN EQUIPMENT PAD.

PROVIDE CONDUIT HOUSE KEEPING CURB AT ALL LOCATIONS WHERE THE #4 U-SHAPED BARS

LAP SPLICE

CONTINUING DUCTBANK
1 1
TYP
TYP
TYP
TYP
3" CLR COVER
TYP
S
EM033 RISER FROM DUCTBANK

SLAB ON GRADE
EM001
EM001
S180
EM107
TYP
S
EM022 DUCT BANK ENTRY

INTO ELECTRICAL EQUIPMENT

ENCLOSURE

ELECTRICAL

FOUR SIDES

SEALANT ALL
1 1/2" JOINT
TYP
TYP
S180
S350 PAD

HOUSEKEEPING

ELECTRICAL
SLAB

CONCRETE
TYP
EM001

EQUIPMENT GROUND BUS

CONDUCTOR CONNECT TO

GROUNDING ELECTRODE
GENERAL NOTES:

WINDOW IN BOTTOM OF ELECTRICAL ENCLOSURE.

HOUSE KEEPING PAD MUST FIT IN MANUFACTURER PROVIDED
CONDUIT SIZE AND NUMBER OF CONDUITS. CONDUITS AT TOP OF

1. OPENING SIZE IN CONCRETE HOUSE KEEPING PAD IS SET BY #4@12"
#4 U-SHAPED BARS

LAP SPLICE
(TYP)
GRADE

SLAB ON
1 1
3" CLR COVER
TYP
TYP
TYP
TYP
TYP

1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS.

CONTINUING DUCT BANK AS INDICATED ON THE DRAWINGS.

EM001
S180
EM107
S130
EM001
2 2
2 GENERAL NOTES:

KEY NOTES:

SHALL ONLY BE PROVIDED FOR DUCT BANK RISER THROUGH NEW CONCRETE SLAB.

PROTECTED BY AN EQUIPMENT PAD.

PROVIDE CONDUIT HOUSE KEEPING CURB AT ALL LOCATIONS WHERE THE CONDUIT IS NOT TYP
EM032

SLAB ON GRADE

RISER FROM DUCT BANK
R 12-06-21
(TYP
)"
18"
R
PLACEMENT & CURING.

3. MAKE PROVISIONS TO PREVENT CONDUIT FLOTATION DURING CONCRETE CONDUIT SCHEDULE FOR NUMBER AND SIZE OF CONDUITS.

CONDUITS WITHIN DUCT BANK. REFER TO DUCT BANK SECTIONS, AND SPECIFICATION SECTION 16133 TO ACCOMMODATE ACTUAL NUMBER OF

2. ADJUST SIZE OF DUCT BANK BASED UPON THESE GUIDELINES AND

1. DIMENSIONS SHOWN ARE MINIMUM.

NOTES:
4 3
2 1
5 CONCRETE POUR.

CONDUIT LOCATION AND TO PREVENT IT FROM FLOATING DURING

OR CLOSER SPACING ALONG THE LENGTH AS REQUIRED TO MAINTAIN TIE CONDUIT TO BOTTOM REINFORCING STEEL AT MIN 2'-0" ON CENTER CONDUIT REQUIREMENTS.

REFER TO DUCTBANK SECTIONS AND CONDUIT SCHEDULES FOR
MOVEMENT OF THE REBAR.

BANK OR CLOSER SPACING AS NECESSARY TO PREVENT SAGGING OR UNDER STIRRUPS AT MIN 4'-0" ON CENTER ALONG LENGTH OF DUCT

MINIMUM OF THREE PRECAST CONCRETE BAR SUPPORTS PLACED
LENGTH OF DUCT BANK.
#4 REINFORCING STEEL STIRRUPS 6" MAXIMUM ON CENTER ALONG PERIMETER OF DUCT BANK.
#4 REINFORCING STEEL 12" MAXIMUM ON CENTER AROUND ENTIRE KEY NOTES:

TYP
EM002 REDUCED DEPTH REINFORCED CONCRETE DUCT BANK
5 4 1
2 3
(TYP)

INSULATED THROAT

BUSHING WITH

METAL GROUNDING
P
lotD
ate: 06-APR
-2023 11:14:58
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE04
178
8660F1000TE04.dgn

ELECTRICAL
eparker
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:44:33-07'00'

Page 417 of 1800 ends

CHANNEL CAP

CONDUIT

CHANNEL

PREFORMED

ANCHORS

CONCRETE
GROUT
1" NON-SHRINK

CONDUIT CLAMP
3"
3 -1/2"

PVC CONDUIT
FLOOR

FINISHED

TO FLOOR

DOWEL CURB

CHAMFER

CONDUIT
#3 HOOP
DRAINAGE.

TOP OF CURB FOR

CROWN OR SLOPE

STEEL CONDUIT

PVC COATED
(TYP)

CONDUIT COUPLING
(TYP
)"
12"

PVC FEMALE ADAPTER

ELBOW (TYP)

STEEL CONDUIT

PVC COATED

GRADE AT OPEN AREAS GRADE AT ROADWAYS
4"
6"M
IN
WALL
EN
C
A
S
EM
EN
T
H
E
IGH
T, H

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
10' MAX
6"
1 # KEY NOTES:

AND LARGER.

3. FIELD BEND 1" CONDUITS. PROVIDE MANUFACTURED PCS ELBOWS FOR CONDUITS 1.25"

2. TYPICAL BOTH SIDES, FRONT AND REAR.

1. COORDINATE REINFORCING STEEL REQUIREMENTS WITH THE GENERAL CONTRACTOR.

EM107
TYP

CONDUIT HOUSEKEEPING CURB
S
3 2
1 SUBGRADE

PREPARED
GRADE

FINISHED
PANEL

KNOCKOUT

PRE-FORMED
HATCH

ACCESS ROADWAY

COATING

EXTERIOR

DRAIN SUMP

GROUND ROD
3/4" x 10'-0"

PULLING IRON (TYP)
1 6
3 5
8 4
2 MAX
6"

MATERIAL
BASE 9
(TYP 4 SIDES)
12" MIN
TYP
EM001
TYP
EM070
(TYP)
TYP
EM056

PRECAST CONCRETE W/HATCH

ELECTRICAL HANDHOLE
J
#
GENERAL NOTES:

KEY NOTES:

BANKS AT EACH HANDHOLE.

3. SEE DRAWINGS FOR ORIENTATION, NUMBER, AND SIZE OF DUCT USING #4 AWG BARE COPPER CABLE.

2. BOND ALL METALLIC ITEMS INSIDE HANDHOLE TO GROUND ROD INTERIOR DIMENSIONS: 60"WIDE x 60"LONG x 60"DEEP)

ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE (MAXIMUM

1. PROVIDE MINIMUM INTERIOR DIMENSIONS AS SHOWN IN THE
COURSE.

9. BASE MATERIAL: PROVIDE MIN 12" COMPACTED AGGREGATE BASE

8. PROVIDE ONE PULLING IRON ON EACH WALL OF HANDHOLE.

FOR CONNECTION REQUIREMENTS.

7. GROUNDING CABLE CONNECTION. REFER TO THE SPECIFICATIONS HANDHOLE.

6. MAXIMUM TOP SLAB OVERHANG IS TYPICAL AROUND 4 SIDES OF PROOFING.

5. COAT EXTERIOR WALLS BELOW GRADE WITH BITUMINOUS DAMP BASE MATERIAL BELOW.

MINIMUM 18" SQUARE FILTER FABRIC TO ISOLATE GRAVEL FROM THROUGH FLOOR OF HANDHOLE. SET SUMP OPENING OVER

4. PROVIDE MINIMUM 4 INCH DIAMETER, GRAVEL FILLED PENETRATION WALL AROUND HANDHOLE.

PREFORMED KNOCKOUT PANELS. PROVIDE KNOCKOUTS ON EACH

3. INSTALL DUCT BANKS ONLY THROUGH CAST-IN OPENINGS OR
SPECIFICATIONS FOR CONNECTION REQUIREMENTS.

2. BOND DUCT BANK GROUND CABLE TO GROUND ROD. REFER TO THE LOAD RATING OF HATCH.

1. SEE THE MANHOLE AND HANDHOLE SCHEDULE FOR REQUIRED
TYP
EM103

PREFORMED CHANNEL
316 STAINLESS STEEL

ANCHORS

CONCRETE

HARDWARE

STAINLESS STEEL LENG
TH
A
S
R
EQU
IR
ED
EDG
E
D
IS
T
6"M
IN UON. 11/2"
6"

CONDUIT SUPPORT
S
TYP
S
EM104

FOR ELECTRICAL CONDUITS

CONDUIT FLOOR SUPPORT
# KEY NOTES:

DRAWINGS.

1. SIZE PREFORMED CHANNEL FOR CONDUITS INDICATED ON THE S
EM070 ENCASED CONDUITS AT MANHOLES OR

CONDUIT(S)

OUTSIDE OF

STRUCTURE

INSIDE OF

DUCTBANK)
1" (TYP AROUND

STIRRUPS
1 STRUCTURE

FITTING (TYP)

END BELL

CONDUCTOR

GROUNDING
2 4
3 EM001
S130
S180

REINFORCEMENT

LONGITUDINAL

TYP STRUCTURES - W/O WATERSTOP
TYP
TYP
TYP
# KEY NOTES:

REINFORCEMENT PER
REQUIRED. FOR CAST-IN-PLACE STRUCTURES, PROVIDE

4. PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENING AS
ALTERNATE WITH TYPICAL REINFORCEMENT FOR 6" SPACING.

3. ADDITIONAL #4 x 12'-0" @ 12" ON ALL FOUR FACES OF ENCASEMENT.

HEIGHT IN INCHES.

SPACING IN INCHES = (H-4)/2 WHERE H = CONCRETE ENCASEMENT

2. FOR FIRST 12'-0" FROM INSIDE FACE OF STRUCTURE, STIRRUP CONDUCTOR.

MANHOLE. BOND GROUNDING FITTING TO DUCTBANK GROUNDING

1. PROVIDE GROUNDING FITTING FOR METALLIC CONDUITS ENTERING TYP
S
EM102 TRAPEZE SUPPORT
LENGTH

SUPPORT

CHANNEL

PREFORMED

AND DOUBLE NUT

SQUARE WASHER
(LENGTH AS REQUIRED)
3/8" THREADED ROD

REFER TO ATTACHMENT DETAIL

PREFORMED CHANNEL
GENERAL NOTES:

3. REFER TO SPECIFICATIONS FOR MATERIAL REQUIREMENTS.

2. PROVIDE SEISMIC BRACING PER THE SPECIFICATIONS.

INSTALLED.

SUPPORTS AS REQUIRED BY EQUIPMENT AND MATERIALS TO BE

1. PROVIDE NUMBER AND LENGTH OF PREFORMED CHANNEL

ENCASED CONDUITS

EXPOSED CONDUITS

WASHER OR HEX NUT

CONDUIT CAP

NYLON PULL ROPE

NUT TO PIPE CAP

WELD WASHER OR HEX
STEEL CONDUIT.

PVC COATED RIGID
STEEL COUPLING.

PVC COATED RIGID
TYP
S
EM105 SPARE CONDUIT DETAIL

WASHER OR HEX NUT

TIE PULL ROPE TO
CURB

OR HOUSEKEEPING

FINISHED FLOOR
GENERAL NOTES:

1. PROVIDE 2" MIN CLEAR BETWEEN ADJACENT CONDUITS

STEEL CONDUIT

PVC COATED RIGID

WITH THE CURB

COUPLING BOOT FLUSH

CUT PVC COATING
COATED CONDUITS.

EXTEND SPARE

CAN BE USED TO

SEALING LOCKNUT

RIGID STEEL

AND PVC COATED

MAY BE REMOVED

IN FUTURE, PLUG
PLUG.

BRASS CONDUIT
7 P
lotD
ate: 06-APR
-2023 11:14:07
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE05
8660F1000TE05.dgn

ELECTRICAL
ggraham
179
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:43:20-07'00'

Page 418 of 1800 ends

SET TOP OF MANHOLE FLUSH

AT PAVING OR SIDEWALKS,

FRAME AND MANHOLE COVER
36"Ø EMBEDDED TOP FLANGE

COATING

EXTERIOR

TIE - OFF
LADDER

SET TOP OF MANHOLE FLUSH

AND/OR RISERS AT PAVING OR SIDEWALKS

PRECAST GRADE RINGS
COVER

FRAME AND MANHOLE
36"Ø BOTTOM FLANGE

SUBGRADE

PREPARED

BASE MATERIAL
(LOCATIONS PER FABRICATOR)

PRECAST STRUCTURE JOINT

CHANNELS FOR CABLE RACKS

PREFORMED AND EMBEDDED

MANHOLE BASE

GROUND CABLE

BANK COPPER
#4/0 BARE DUCT
1/2"Ø TYPE 316 SST ROD
12" (TYP)
31/2"

BASE MATERIAL

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
IRON

PULLING

COATING

EXTERIOR

AROUND)

AREAS (TYP

CABLE ROUTING
IRON

PULLING

GROUND ROD
3/4" x 10'-0"

REINFORCING BARS

TIE INTO TOP OF SLAB

SURROUNDING GRADE
MANHOLE 2" TO 4" ABOVE

AT EARTH, SET TOP OF
MAX
8"
TYP
S
EM062

PRECAST CONCRETE
ELECTRICAL MANHOLE:

B SECTION
-
C
-
D
-

SLOPE SLOPE
PANEL

KNOCKOUT

PREFORMED
ACCESS

MANHOLE
C
LR
M
IN
C
LR
M
IN

SLOPE SLOPE

SURROUNDING GRADE
MANHOLE 2" TO 4" ABOVE

AT EARTH, SET TOP OF
#5 @ 12" EW

CONCRETE

CLASS B

CLASS A OR
SUMP

CAST-IN
SUMP

CAST-IN
(ABOVE
)
ACC
ESS

CAST-IN SUMP
A

LADDER TIE - OFF

PLAN - LAYOUT
E
-
S
O
IL
18" 36"

DUCT BANK
24" MIN
W
ID
TH
LENGTH
18"
6"M
IN
2"C
LR
6"M
IN
12" MIN
4"M
IN
2'-0"M
IN

LADDER TIE-OFF
3'-0"M
IN
C
LR
(TYP
)
BANK
DUCT
BANK
DUCT
BANK
DUCT
ALTERNATE 1: SECTION

EXPOSED TOP SLAB
MAX
8"

BASE WITH SUMP OR BALLAST
C
ALTERNATE 2: SECTION
OVER
6" MIN
6" MIN
R = 2 1/2"
R = 2 1/2"
6" MIN
12" MIN
(TYP 4 SIDES)
(12"M
IN
)
B
-

TYP (TYP)
EM001
4 8
13 12
10 11
S055
CS124
1 10
2 3
9 5
4 5
6 13
7 9
TYP
EM070

DUCT BANKS)
(TYP AT
S055
GENERAL NOTES:

KEY NOTES:
14 TYP
TYP
TYP
#
CLAMPS PER TYPICAL DETAIL EM076.

5. RACK MEDIUM VOLTAGE CABLES USING PORCELAIN INSULATOR BANKS AND PENETRATIONS AT EACH MANHOLE.

4. SEE DRAWINGS FOR ORIENTATION, NUMBER, AND SIZE OF DUCT USING #4 AWG BARE COPPER CABLE.

3. BOND ALL METALLIC ITEMS INSIDE MANHOLE TO GROUND ROD HANDHOLE AND MANHOLE SCHEDULE.

2. PROVIDE MANHOLE ALTERNATES (TOP OR BASE) AS SHOWN IN THE ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE.

1. PROVIDE MINIMUM INTERIOR DIMENSIONS AS SHOWN IN THE
H
E
IGH
T

15. SLOPE TO BE COMPLETED BY CONTRACTOR.

INTO CONCRETE SEE SECTION 16070 - HANGERS & SUPPORTS.

MAY NOT BE REQUIRED FOR PRODUCTS WHICH SECURE DIRECTLY

14. USE OF PREFORMED AND EMBEDDED CHANNELS FOR CABLE RACKS DETAIL E.

13. AT ONE SIDE OF MANHOLE ACCESS, PROVIDE LADDER TIE - OFF PER PLACING, FINISHING AND CURING REQUIREMENTS.

12. SEE SPECIFICATIONS FOR CAST-IN-PLACE CONCRETE FULL MIXING, COVER.

LOCATE SUMP OUTSIDE VERTICAL CORRIDOR BELOW MANHOLE

11. MINIMUM 12" DIAMETER SUMP WITH REMOVABLE SLOTTED COVER.

10. PROVIDE MIN 12" COMPACTED AGGREGATE BASE COURSE.

EACH DUCT BANK PENETRATION.

9. PROVIDE ONE PULLING IRON ON EACH WALL ABOVE OR BELOW PROOFING. LEAVE EXPOSED TOP SLAB UNCOATED.

8. COAT EXTERIOR WALLS OF MANHOLE WITH BITUMINOUS DAMP
BITUMINOUS DAMP PROOFING.

7. COAT EXTERIOR WALLS AND BURIED TOP SLAB OF MANHOLE WITH WALL AROUND MANHOLE.

PREFORMED KNOCKOUT PANELS. PROVIDE KNOCKOUTS ON EACH

6. INSTALL DUCT BANKS ONLY THROUGH BLOCKOUTS, WINDOWS OR SEE SPECIFICATIONS FOR CONNECTION REQUIREMENTS.

5. BOND DUCT BANK AND INTERIOR GROUND CABLE TO GROUND ROD.

CORRIDOR BELOW MANHOLE COVER.

SLOTTED COVER. LOCATE SUMP OUTSIDE VERTICAL ACCESS

4. MINIMUM 12" DIAMETER x MIN 2" DEEP SUMP WITH REMOVABLE AND MAXIMUM 24" ON CENTER AROUND PERIMETER OF MANHOLE.

3. SPACE EMBEDDED CHANNELS TO CLEAR DUCT BANK KNOCKOUTS D (ALTERNATE 2).

SUMP OR CONCRETE BALLAST TO RESIST FLOTATION, SEE SECTION

2. STANDARD MANHOLE BASE SHOWN. FOR MANHOLES WITH DEEPER (ALTERNATE 1).

FOR MANHOLES WITH EXPOSED TOP SLAB, SEE SECTION C

1. MANHOLE ACCESS FOR BURIED MANHOLE SHOWN IN SECTION B. 15 15
P
lotD
ate: 06-APR
-2023 12:58:29
PM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE06
8660F1000TE06.dgn

ELECTRICAL
ggraham
180
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:42:54-07'00'

Page 419 of 1800 ends

CONDUIT
2"
DRAWINGS.

SEE STRUCTURAL
FOR CORE DRILLING.

DIRECTION REQUIRED

MIN SPACING IN EACH
REINFORCEMENT AT 12"
SLAB

CONCRETE
APPLICABLE.

HOUSEKEEPING CURB AS
EM107 OR EQUIPMENT
SLAB

CONDUIT
SLAB

CONDUIT
(TURNING)

CONDUIT
SLAB

CONDUIT

EPOXY GROUT

NON-SHRINK

FILL WITH

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

S101
S101

S101
EM163
S
TYP

CORE DRILLED PENETRATION

CONCRETE WALL

CONDUIT

CONCRETE WALL
CLR
2" MIN

FILL WITH NON-SHRINK GROUT
(NOTE 3)
SEE STRUCTURAL DRAWINGS.

REQUIRED FOR CORE-DRILLING.

SPACING IN EACH DIRECTION
REINFORCEMENT AT 12" MIN
GENERAL NOTES:

REFER TO STRUCTURAL DRAWINGS.

REINFORCEMENT SPACING LESS THAN 2" IN EACH DIRECTION.

3. PROVIDE CAST-IN SLEEVE FOR PENETRATIONS IN WALLS WITH SURFACE PRIOR TO GROUTING.

2. APPLY EPOXY CEMENT BONDING AGENT OR ROUGHEN CONCRETE DRILLED OPENING AND REINFORCEMENT.

OF REINFORCEMENT. MAINTAIN MIN 2" CLEAR BETWEEN CORE

1. PROVIDE NON-DESTRUCTIVE TESTING TO DETERMINE LOCATIONS

TYP

MIN CLR
GENERAL NOTES:

2. APPLY EPOXY CEMENT BONDING AGENT PRIOR TO GROUTING.

DRILLED OPENING AND REINFORCEMENT.

OF REINFORCEMENT. MAINTAIN MIN 2" CLEAR BETWEEN CORE

1. PROVIDE NON-DESTRUCTIVE TESTING TO DETERMINE LOCATIONS EM139

CONCRETE SLAB

CORE DRILLED PENETRATION
S

AROUND)
(TYP ALL
MAX 1 1/2"
MIN 1"
TYP
KEY NOTES:

CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.

MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
PREVENT FLOTATION.

OR BOLSTERS. TIE CONDUITS TO SUPPORTS & ANCHOR TO

SUPPORT CONDUITS ON ADDED REINFORCEMENT CHAIRS
TYP
SEE DETAIL.

FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
PLACING CONCRETE.

MAINTAINED, CONTACT ENGINEER FOR INSTRUCTION'S BEFORE

WHERE HORIZONTAL & VERTICAL CLEARANCES CANNOT BE

1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.

NOTES:

EACH PAIR.

HORIZONTAL & VERTICAL SPACING SHOWN BETWEEN
4 WHERE MORE THAN 2 RUNS ARE STACKED, PROVIDE
3 2
1 3
1 1
2 MIN 1 1/2" CLEAR
MIN 2" CLEAR
MIN 1 1/2" CLEAR
TYP

REINFORCEMENT MAT

TOP STRUCTURAL

REINFORCEMENT MAT

BOTTOM STRUCTURAL
EM116
TYP
S

STACKED RUNS

EMBEDDED CONDUIT IN CONCRETE SLAB
KEY NOTES:

CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.

MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
AND BOTTOM REINFORCEMENT MATS.

CENTER LARGEST DIAMETER CONDUIT BETWEEN TOP
SEE DETAIL.

FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
PLACING CONCRETE.

MAINTAINED, CONTACT ENGINEER FOR INSTRUCTION'S BEFORE

WHERE HORIZONTAL & VERTICAL CLEARANCES CANNOT BE

1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.

NOTES:
4 3
4 3
2 1
1 1
2 MIN 1 1/2" CLEAR
MIN 1 1/2" CLEAR
TYP

REINFORCEMENT MAT

TOP STRUCTURAL

REINFORCEMENT MAT

BOTTOM STRUCTURAL
TYP
TYP
PREVENT FLOTATION.

OR BOLSTERS. TIE CONDUITS TO SUPPORTS & ANCHOR TO

SUPPORT CONDUITS ON ADDED REINFORCEMENT CHAIRS
EM115
TYP
S

SINGLE RUN

EMBEDDED CONDUIT IN CONCRETE SLAB
KEY NOTES:

PLACING CONCRETE.

MAINTAINED, CONTACT ENGINEER FOR INSTRUCTION'S BEFORE

WHERE HORIZONTAL & VERTICAL CLEARANCES CANNOT BE

1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.

NOTES:

SEE DETAIL.

FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.

MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
SAME HORIZONTAL PLAN.

THAN DIAMETER OF THE LARGER CONDUIT IN THE

SPACING BETWEEN PARALLEL CONDUITS NOT LESS

WHERE CONDUITS CROSS, PROVIDE MIN HORIZONTAL
& MAINTAIN CLEARANCE SHOWN.

SUPPORT CONDUITS AT CROSSING TO PREVENT SAG
EACH PAIR.

HORIZONTAL & VERTICAL SPACING SHOWN BETWEEN
6 WHERE MORE THAN 2 RUNS ARE STACKED, PROVIDE
5 3
2 4
3 1 4
3 5
2 1
1 TYP

REINFORCEMENT MAT

TOP STRUCTURAL

REINFORCEMENT MAT

BOTTOM STRUCTURAL
TYP
TYP
MIN 1 1/2" CLEAR
MIN 2" CLEAR
MIN 1 1/2" CLEAR
CONDUITS TO SUPPORTS & ANCHOR TO PREVENT FLOTATION.

OCM METAL BAR SUPPORT PRODUCT TYPE OR EQUAL. TIE

SUPPORT CONDUITS ON ADDED REINFORCEMENT BOLSTERS,
EM117 EMBEDDED CONDUIT IN CONCRETE SLAB

TYP CROSSING RUNS
S

AROUND)
(TYP ALL
MAX 1 1/2"
MIN 1"
P
lotD
ate: 06-APR
-2023 11:13:52
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE07
8660F1000TE07.dgn

ELECTRICAL
ggraham
181
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:44:02-07'00'

Page 420 of 1800 ends

1'-4" SQ
3"
10"
1"(TYP)
3/8"
6"
4'-0" MAX
1'-6" SQ
3"
1 1/2" (TYP)
EM
B
ED
M
EN
T
2'-6"M
IN
4-#5
#3 @ 6"
GROUT
1" NON-SHRINK
BOLTS
ANCHOR 3/4 x 12 x 12
AL PL
5 SQ
GROUT
1" NON-SHRINK
AL 5 SQ x 0.250 WALL
3/8 AL PL
1/2" RADIUS (TYP)

ROUND CORNERS TO
1/4 AL PL

TYP DEVICE
5'-0"MAX
6'-6"MAX
5'MAX
4'-0" MAX
6"
6"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®

C POST BASE

B SECTION
5 2
AL CS6 x 4.03
ROUND CORNERS TO 1/2"
4'-6"MAX
CL

CONC ANCHORS
1" NON-SHRINK
GROUT

RADIUS (TYP)
#3 @ 6"
4 - #5
1/4
TO
C
ENTER
O
F
D
EV
IC
E
GROUT
1" NON-SHRINK

ANCHORS
EM
B
ED
M
EN
T
2'-6"M
IN
AL PL
5/8"

4. WEIGHT OF DEVICE(S) SHALL NOT EXCEED 100 POUNDS.

3. USE STAINLESS STEEL FASTENERS FOR MOUNTING DEVICES.

2. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE PER SPECIFICATIONS.

1. WHERE SEPARATE FOUNDATION IS REQUIRED, SEE SECTION B.

NOTES:

C
-

ELEVATION
-
A
B
-

SECTION
-
C
C
-

SECTION
EM201
S
TYP

DEVICE SUPPORT AND MOUNTING
CL
CL
CL
1/4
1/4
1/4
GENERAL NOTES:

4. WEIGHT OF DEVICE(S) SHALL NOT EXCEED 300 POUNDS.

3. USE STAINLESS STEEL FASTENERS FOR MOUNTING DEVICES.

SPECIFICATIONS.

2. COAT ALUMINUM SURFACES IN CONTACT W/ CONCRETE PER

1. USE ELEVATION B WHERE A SEPARATE FOUNDATION IS REQUIRED.

A
-

ELEVATION
-
C
C
-

SECTION
C
-
TYP
S
EM202 DEVICE SUPPORT AND MOUNTING
B
-

ELEVATION

CONDUIT
GROUT

NON-SHRINK

FILL WITH

3. PROVIDE 8" MINIMUM CENTER-TO-CENTER SPACING FOR CONDUITS.

AGENT IMMEDIATELY PRIOR TO GROUTING.

2. ROUGHEN SURFACE OF OPENING TO A 1/4" AMPLITUDE AND APPLY EPOXY CEMENT BONDING MAINTAIN MIN 2" CLEAR BETWEEN CORE DRILLED OPENING AND REINFORCEMENT.

1. PROVIDE NON-DESTRUCTIVE TESTING TO DETERMINE LOCATIONS OF REINFORCEMENT.

NOTES:

CMU WALL
EM173
S
TYP

CORE HOLE PENETRATION

FULLY GROUTED CMU WALL
4 B
-
TYP
EM211 OUTDOOR EQUIPMENT MOUNTING STAND
S
# KEY NOTES:

JUNCTION BOXES.

5. OPTIONAL HORIZONTAL SUPPORTS AND AVAILABLE SPACE FOR PREFORMED CHANNEL.

ENCLOSURES THAT CAN BE MOUNTED DIRECTLY TO THE

4. PROVIDE ADDITIONAL PREFORMED CHANNEL SUPPORTS FOR
THE MOUNTING BOARD SHALL BE DESIGNED BY THE CONTRACTOR.

DIRECTLY TO PREFORMED CHANNEL. EQUIPMENT ANCHORAGE TO
WEIGHING LESS THAN 20 POUNDS THAT CANNOT BE MOUNTED

3. PROVIDE A MOUNTING BOARD FOR INSTRUMENTS AND DEVICES ENCLOSURES IS 1'-6".

2. MAXIMUM OFFSET TO THE CENTERLINE OF EQUIPMENT OR
SPACED VERTICAL SUPPORTS AT 4 FOOT MAXIMUM SPACING.

1. FOR MOUNTING STANDS WIDER THAN 4 FEET PROVIDE EQUALLY GENERAL NOTES:

PREFORMED SINGLE CHANNELS.

CHANNELS. HORIZONTAL SUPPORTS SHALL CONSIST OF

5. VERTICAL SUPPORTS SHALL CONSIST OF PREFORMED DOUBLE
SPECIFICATIONS.

METALS, ISOLATE DISSIMILAR METALS AS SPECIFIED IN THE

4. WHERE CONCRETE ANCHORS COME IN CONTACT WITH DISSIMILAR

3. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS.

SUPPORT.

BOARDS SHALL NOT EXCEED 12 SQUARE FEET PER VERTICAL

2. THE TOTAL SURFACE AREA OF ALL EQUIPMENT AND MOUNTING DESIGN CALCULATION SUBMITTAL REQUIREMENTS.

LIMITATIONS IN THIS DETAIL. REFER TO THE SPECIFICATIONS FOR

EXCEEDS THE SPECIFIED DESIGN CRITERIA OR DIMENSIONAL

SUBMIT DESIGN CALCULATIONS FOR EACH INSTALLATION THAT
- MAXIMUM EQUIPMENT LOAD OF 100 LBS PER VERTICAL SUPPORT - RISK CATEGORY: III AND IV
- SEISMIC DESIGN CATEGORY: A THROUGH D
- NON -SPECIAL WIND REGIONS
- WIND EXPOSURE CATEGORY: C
120 MPH
- BASIC WIND SPEED (3 SECOND GUST. 33 FEET ABOVE GROUND) :

CHANNEL
- STAINLESS STEEL OR HOT-DIPPED GALVANIZED PREFORMED
FOLLOWING DESIGN CRITERIA.

1. AS SHOWN, THE MOUNTING STAND IS SUITABLE FOR THE
C
-
3-1/4"

CHANNEL

PREFORMED

PLATE (TYP)
3-HOLE CORNER

PLATE (TYP)
4-HOLE TEE

SUPPORT (TYP)

VERTICAL

SUPPORT (TYP)

HORIZONTAL
3 1/2" MIN
3 BOARD

MOUNTING
1 1'-0
"
M
IN

GROUT (TYP)
1" NON-SHRINK

AROUND)
(TYP ALL
MAX 1 1/2"
MIN 1"

CHANNEL MOUNTING

POST BASE FOR DOUBLE

PREFORMED CHANNEL
(TYP)
W/ 5" MIN EMBED.

CONCRETE ANCHOR
1/2" DIAMETER
P
lotD
ate: 06-APR
-2023 11:14:22
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE08
8660F1000TE08.dgn
ggraham
ELECTRICAL 182
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:43:45-07'00'

Page 421 of 1800 ends

FASTENER
SST 1/2"
FRAME

BUILDING STEEL
SIDING

BUILDING METAL

PLYWOOD

CEILING

DISCONNECT

JUNCTION BOX

POWER OUT

POWER IN/

CHANNEL

PREFORMED

CONDUIT

CHANNEL

PREFORMED

ANCHORS
WOOD
JOIST

CEILING

DRYWALL

CEILING

CONDUIT CLAMP

CONDUIT

CHANNEL

PREFORMED

ANCHORS
WOOD
JOIST

CEILING

DRYWALL

CEILING

CONDUIT CLAMP

PLYWOOD

CEILING
18"
18"
6"
3"

EXPANSION FITTING

JOINT FILLER

COMPRESSIBLE
ALL AROUND.

FROM BUILDING. 1" CHAMFER

CONCRETE SLOPED AWAY

LB CONDUIT FITTING

OR FOUNDATION

FOOTING
SHOWN ON PLANS.

CONCRETE ENCASEMENT WHERE

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
6"
6"

EQUIPMENT
TO
SOURCE

TO POWER

CONTROL
1 1
WALL UNLESS OTHERWISE INDICATED ON THE DRAWINGS.

1. ALL SWITCHES AND RECEPTACLES SHALL BE EMBEDDED IN THE NOTES:
(OFFICE AREAS)

RECEPTACLE

NETWORK JACK AND
(OFFICE AREAS)

INDIVIDUAL RECEPTACLE
FLOOR

FINISHED

DOOR FRAME TRIM

OF STROBE
7'-0" TO BOTTOM
FIRE

CORROSIVE AREAS)
(EQUIPMENT AREAS, WET AND

RECEPTACLE

VERTICALLY WITH SWITCH

THERMOSTAT, ALIGN

CORROSIVE AREAS)
(EQUIPMENT AREAS, WET AND

NETWORK JACK
12" MAX
4'-0" TO TOP

OF PLATES

HORN/STROBE

FIRE ALARM

STATION (WHERE REQUIRED)

FIRE ALARM MANUAL PULL

LIGHT SWITCH
EM725 OUTLET BOX MOUNTING
TYP
S
KEY NOTES:

KELLEMS GRIP

EQUIPMENT CABLE

JUNCTION BOX
CABLE TO FIELD WIRING.

TRANSITION FROM THE EQUIPMENT

PROVIDE TERMINAL STRIPS TO
DETAILS.

CONDUIT AND CABLE SCHEDULE FOR

REFER TO THE ELECTRICAL DRAWINGS,
POWER AND CONTROL CONDUITS.

FOR NEMA TYPE.
3 REFER TO SPECIFICATIONS AND PLANS
3 2
1 1
2 2
TYP
S
EM315 SUBMERSIBLE EQUIPMENT

CABLE CONNECTION DETAIL
GENERAL NOTES:

KEY NOTES:

1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS. #

ABOVE GRADE
EM219 CONDUIT PENETRATION
TYP
2 1
EXPANSION FITTING.

2. DO NOT ATTACH THE CONDUIT TO THE BUILDING BEFORE THE BEFORE INSTALLATION.

MANUFACTURER. SUBMIT TO ENGINEER OF RECORD FOR REVIEW

SHALL INCLUDE CAULKING AND PLATE AS RECOMMENDED BY
WEATHERTIGHT SEAL AROUND THE CONDUIT PENETRATION. SEAL

1. CONTRACTOR SHALL PROVIDE A WATERPROOF AND
TYP
S
EM221 DISCONNECT CONDUIT INSTALLATION
#
GENERAL NOTES:

KEY NOTES:

1. CONDUIT AND ENCLOSURE REQUIREMENTS AS SPECIFIED.

QUANTITY.

3. REFER TO CONDUIT SCHEDULE FOR CONDUIT SIZE, WIRE SIZE AND

2. SIZE CONDUIT IN ACCORDANCE WITH THE NEC.

1. CONDUIT IS NOT INCLUDED IN THE CONDUIT SCHEDULE.

GRADE
#4/0 S.D.B.C.

CONTINUOUS LENGTH

ANTENNA MAST ONE

STEEL PIPE FOR

HEAVY WALL STAINLESS
TYP

ANTENNA
EG201

WEATHER GUARD CAP
BANDING (5' ON CENTER)

STAINLESS STEEL
ANTENNA MAST WITH 3/4"
SECURE 1" CONDUIT TO
MIN. 6" ALONG THE PIPE MID RUN.

THE STRUCTURE EDGE, AND
DISTANCED FOR MIN. 3' NEAR

ATTACHMENTS SHALL BE
STRUCTURE. PIPE SUPPORTING

SECURE ANTENNA MAST ON
CABLE.

CONDUIT AND ANTENNA

BOOT TO SEAL AROUND

HEAT SHRINK RUBBER
1 2
DETAILS AND NOTES.

AND STRAP CLAMPS. REFER TO PLAN DRAWINGS FOR ATTACHMENT

2. SUPPORT STEEL PIPE ON STRUCTURE WITH PREFORMED CHANNEL

1. TO FIELD MOUNTED JUNCTION BOX.

KEYNOTE:

STRUCTURE
TYP
EM903
J 11/24/2021

ATTACHMENT TO STEEL FRAMING WALL
SIZE PREFORMED CHANNEL FOR CONDUITS INDICATED ON THE DRAWINGS.

KEY NOTES:
1 SINGLE JOIST

PARALLEL JOISTS
TYP
EM901

FOR ELECTRICAL CONDUITS

CONDUIT SUPPORT ABOVE CEILING JOIST
J 11/24/2021
TYP
EM902
J 11/24/2021

MOUNTING DETAIL

ANTENNA MAST
1 2
3 3
3 P
lotD
ate: 06-APR
-2023 11:16:26
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE

TYPICALS

TYPICAL DETAILS
8660F10
CE
JGB
00TE09
8660F1000TE09.dgn
ggraham
ELECTRICAL 183
Digitally signed by Erik M. Bahneman
Contact Info: Carollo Engineers, Inc.

Date: 2023.04.07 15:42:39-07'00'

Page 422 of 1800 ends

CONDUIT "LL"

HAND RAIL

MOUNTING STAND

SENSOR CABLE
WEIR
D

ASSEMBLY

SWING MOUNTED

FLOW TRANSMITTER

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
8660F.10
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
APRIL 2023 OF 200

CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
No. 22911
J
NA901
TYP
03/8/2023

PIPE MOUNTING STAND - WEIR LEVEL PROBE
L
C

FLOW SWITCH

THERMAL

FLOW STREAM

EXTEND TO CENTER OF

SENSING ELEMENTS TO
PROCESS CONNECTION.

PROVIDE 3/4" NPT FEMALE

FLEXIBLE CONDUIT
TYP
S
NF111 THERMAL FLOW SWITCH MOUNTING DETAIL

STRAIN RELIEF

HIGH ALARM FLOAT

PUMP-ON FLOAT

PUMP-ON FLOAT
ANCHOR

PVC COATED
TYP
S
NL108 LEVEL FLOAT WITH CHAIN

FLOAT CLAMP (TYP)

PUMP OFF FLOAT

1. NUMBER OF FLOATS AS SHOWN ON DRAWINGS.

NOTES:

PVC COATED CHAIN

CARABINER
CHAIN

PIPE CAP

STRAIN RELIEF

PIPE CAP
LEVEL

HANGING POSITION HIGH

FLOAT SHOWN IN FREE
ANCHOR

APPROVED STRAP AND

SECURE PIPE TO WALL WITH
WALL EVERY 36"

SECURE PIPE TO
(TYP)
EVERY 36"

CABLE TIE
TYP
S
NL101 FLOAT SWITCH INSTALLATION
1-#8 XHHW-2

GROUND TERMINAL

TRANSMITTER

FLEXIBLE CONDUIT
1-#8 XHHW-2

POWER CONDUIT

SIGNAL CONDUIT

GROUND RINGS
4 2
4 3
1 3
2 1
TYP
S
NF136

GROUNDING DETAIL

INTEGRAL MAGNETIC FLOWMETER
KEY NOTES:
5 5
METER
P
IPE
5 CONNECT TRANSMITTER GROUND TERMINAL TO GROUND RINGS.

CONNECT METER BODY TO EARTH GROUND POTENTIAL.

MAGMETER.

EQUALIZE POTENTIAL VIA GROUND RINGS BETWEEN FLUID AND
5 PROVIDE BONDING JUMPER ON CONDUCTIVE PIPES.

EARTH GROUND AND TRANSMITTER GROUND TERMINAL.

CONTRACTOR SHALL VERIFY ZERO POTENTIAL BETWEEN FLOW TUBE,

POSITION PUMP OFF FLOAT

SUBMERGED (OPERATED)

CONCRETE BOTTOM

SOCKET OR ROD IN

PUMP-ON FLOAT

HIGH ALARM FLOAT

PUMP-OFF FLOAT

STRAIN RELIEF

CABLE TIE (TYP)
TYP
S
NL100 FLOAT SWITCH INSTALLATION
GENERAL NOTES:

2. FLOATS SHOWN IN FREE HANGING POSITION.

P&IDS.

1. NUMBER OF FLOATS SHALL BE AS SHOWN ON SCHEMATICS AND

SAMPLE LINE
DRAIN

REAGENT
TYP
R
NA090 SAMPLE PANEL PLUMBING DETAIL
# KEY NOTES:
1 3 2
1 4
DRAIN

PROCESS
4 ALARM 2
ALARM 1
SYSTEM
ALARM

ANALYZER

CHEMISTRY

TYPICAL WET
7 5. PROVIDE GLOBE VALVE FOR FLOW CONTROL.

4. PROVIDE AIR GAPS FOR ALL DRAINS.

3. MINIMIZE SAMPLE LINE LENGTH TO KEEP SAMPLE FLOW LAG TO A MINIMUM.

INSTRUMENT.

2. PROVIDE ISOLATION VALVE AND ROTAMETER WITH FLOW CONTROL FOR EACH EXCEEDING 40 PSI.

1. PRESSURE CONTROL VALVE AND GAUGE ARE REQUIRED AT PRESSURE 11/9/2022
TYP
S
NF130
#
GENERAL NOTES:

KEY NOTES:

THE MECHANICAL DRAWINGS FOR INSTALLATION.

4. FOR METERS SPECIFIED WITH ZERO DIAMETER FEATURE, REFER TO

3. MOUNT METER SO THAT IT REMAINS FULLY FLOODED.

OPPOSITE SEQUENCE.

2. ALWAYS TIGHTEN FLANGE BOLTS UNIFORMLY AND IN DIAGONALLY OR DAMAGE THE LINE.

OVERTIGHTENING THE FASTENERS WILL DEFORM SEALING FACES
SETTINGS. DO NOT OVER-TORQUE FLANGE BOLTS.

1. FOLLOW MANUFACTURER'S RECOMMENDED MAXIMUM TORQUE
THE METER.

DIAMETERS UPSTREAM AND 3 PIPE DIAMETERS DOWNSTREAM OF

2. INSTALL METER SUCH THAT THERE ARE NO PIPE BENDS FOR 5 PIPE SHALL BE INSTALLED AT THE METER HOUSING.

1. PIPE SUPPORTS BY MECHANICAL CONTRACTOR. NO SUPPORTS

MAGNETIC FLOWMETER MOUNTING DETAIL
1 2 2
FLOW
NOTES:

HORIZONTAL PIPE AS INDICATED ON THE PLAN DRAWINGS.

1. MOUNT THE SWIVEL / PIVOT / PIPE CLAMP ASSEMBLY TO A GUARDRAIL OR P
lotD
ate: 06-APR
-2023 11:13:11
AM
U
ser:svcPW
Model:

Layout1 C
olorTable:gshade.ctb
D
esignS
cript:

C
arollo_S
td_P
en_v0905.pen
P
lotScale:1:1 LA
S
T
SAVED
B
Y:

PROJECT NO. FILE NAME:

CE
CE

TYPICAL
8660F10
crollins
00TN01
8660F1000TN01.dgn

TYPICAL DETAILS
BAL
INSTRUMENTATION 184

Page 423 of 1800 ends
← All documents from this meeting