Plot Date: 7/12/2023 12:19:15 PM GENERAL NOTES: 1. ALL GROOVED END COUPLINGS TO BE RIGID UNLESS NOTED OTHERWISE. REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 8660F.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" JULY 2023 OF 200 CITY OF UKIAH RECYCLED WATER PROJECT - PHASE 4 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® CONFORMED DOCUMENTS ** 4/7/2023 REACE P. FISHER SEALED BY ORIGINAL ** CA PE NO. 81261 PROJECT NO. LAST SAVED BY: FILE NAME: CABBJD 99M02 84 MECHANICAL RECYCLED WATER PUMP STATION SECTION8660F1099M02.dwg eparker 8660F10 SCALE: FILE: C SECTION 99M01 3/8" = 1'-0" 8660F1000M100 16" RW (TYP) TYP MP034 TO DISTRIBUTION SYSTEM CL 592.00 (TYP) PUMP CAN (TYP) CONCRETE ENCASE PUMP CAN (TYP) CONC CAN BASE SUPPORT (TYP) EL 588.00 (TYP) 14" RW (TYP) RIGID GROOVED END COUPLING (TYP) VERTICAL TURBINE PUMP (TYP) 16"x12" REDUCING BEND A / V VALVE12" MAGNETIC FLOW METER16"x12" RED FUTURE VERTICAL TURBINE PUMP\ 16" RW
REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 8660F.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" JULY 2023 OF 200 CITY OF UKIAH RECYCLED WATER PROJECT - PHASE 4 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® CONFORMED DOCUMENTS ** 4/7/2023 REACE P. FISHER SEALED BY ORIGINAL ** CA PE NO. 81261 Plot Date: 7/12/2023 12:19:07 PM KEY NOTES: 1. 12" MAGNETIC FLOW METER 2. 12" TANK FILL VALVE PER SPECIFICATION SECTION 15117 3. A / V VALVE (TYP) 4. 12"X16" REDUCING BEND 5. RIGID GROOVED END COUPLING # PROJECT NO. LAST SAVED BY: FILE NAME: RPF BBJM 99M03 85 MECHANICAL METER AND CONTROL VALVE PLAN AND SECTION8660F1099M03.dwg eparker 8660F10 SCALE: FILE: E METER & CONTROL VALVE SECTION - 3/8=1'-0" 8660F10M03 SCALE: FILE: D METER & CONTROL VALVE PLAN 99C19 3/8=1'-0" 8660F10M03 TO TANK INLET SEE DWG 99C19 4 FROM RW DISTRIBUTION SYSTEM SEE DWG 99C19 FOR CONTINUATION 16" PW 3'-6" 3 2 1 5 (TYP) 3 418" PW TYP 12" S300 THICK TYP (TYP) MP034 5'-0" MIN. 3'-0" MIN. 2 VAL-99402 1 FIT-99406 16" RW 4 3 TYP MP034 (TYP) 5 (TYP) 4 3 16" RW VAL-99402 FIT-99406 FROM RW DISTRIBUTION SYSTEM SEE DWG 99C19 FOR CONTINUATION CL=603.83 TOC=603.33 CL=595.00+/- CL=590.00 TO TANK INLET SEE DRAWING 99C19 6'-0" 19'-2"
3'-4"
3'-4"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
MATTHEW C. KALLEVANT
SEALED BY
ORIGINAL
**
CA PE NO. 84405
REFRIGERANT LINES (TYP)
CU-99421 2
FCU-99422 1
3 3
TYP
HE620
18" DRYWELL
CU-99422 2
GENERAL NOTES:
1. MOUNT THERMOSTATS AT 48'' AFF AND LABEL
WITH ITS CONTROLLING DEVICE.
2. REFRIGERANT AND CONDENSATE DRAIN PIPING
SHALL NOT BE ROUTED ABOVE ELECTRICALEQUIPMENT. REFRIGERANT PIPING SHALL BEINSULATED PER SPECIFICATION 15000.
3. PIPE SUPPORTS SHALL BE INSTALLED PER DETAIL
MP132/TYP, MP218/TYP, AND MP215/TYP. INSTALL WALL PENETRATIONS PER DETAIL MP302/TYP.
KEY NOTES:
1 MINI-SPLIT FAN COIL UNIT SUSPENDED FROM
CEILING. BOTTOM OF UNIT AT 10'-0 AFF.
2 OUTDOOR CONDENSER UNIT. MOUNT UNIT ON
EQUIPMENT PAD PER S300/TYP.
3 1'' SCHEDULE 40 PVC CONDENSATE DRAIN
ROUTED TO 18'' DRYWELL. SLOPE LINES AT AMINIMUM OF 2% SLOPE. 4 ROUTE REFRIGERANT LINES DOWN INTERIOR SIDE
OF WALL.
#
T
4 T
FCU-99422
TO
FCU-99421
TO
1 FCU-99421
PlotDate:3/3/202312:41:13PM
TCW
AMT
JM
99M04
86 MECHANICAL
ELECTRICAL BUILDING
HVAC FLOOR PLAN AND SCHEDULE
8660F1099M04.dwgeparker8660F10
F
8660F1000H0101
1/2" = 1'-0"
TYP
S300 (TYP)
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE-LINE SYMBOLS
DUPLEX RECEPTACLEQUADRUPLEX RECEPTACLEDUPLEX RECEPTACLE w/SPLIT WIRE WELDING RECEPTACLESPECIAL PURPOSE RECEPTACLETWIST LOCK RECEPTACLE TELEPHONE OUTLETDATA COMMUNICATIONS OUTLET LUMINAIRE IDENTIFICATION LUMINAIRE, EMERGENCY/EXIT BATTERY-POWEREDLUMINAIRE, EMERGENCY BATTERY-POWERED REMOTE(PERTAINS ONLY TO SHEET WHERE NOTE IS FOUND)LUMINAIRE, EMERGENCY BATTERY-POWEREDLUMINAIRE, SURFACE OR PENDANT MOUNTEDLUMINAIRE, FLOOD/SPOTLUMINAIRE, EXIT ONE OR TWO FACES AS INDICATED. ARROW POINTS IN DIRECTION OF EGRESS.LUMINAIRE, WALL WASHER2' X 2' LAY-IN TROFFER2' X 4' LAY-IN TROFFERLUMINAIRE POLE MOUNTED
PHOTOCELL
MOTOR
EQUIPMENT/INSTRUMENT LOCATOR
EXPOSED CONDUITEXPOSED CONDUIT HIDDEN BEHIND WALLS,FLOORS OR OTHER STRUCTURESUNDERGROUND CONDUIT, DIRECT BURIEDCONDUIT VERTICAL CHANGE IN DIRECTIONJUNCTION BOXCONDUIT SEAL
MEDIUM VOLTAGE DISCONNECT SWITCH NON-FUSED CUT OUTMEDIUM VOLTAGE DISCONNECTING FUSE SINGLE FUSE CUT OUTMEDIUM VOLTAGE DISCONNECTING FUSE DOUBLE FUSE CUT OUTMEDIUM VOLTAGE SINGLE FUSEMEDIUM VOLTAGE DOUBLE FUSEMEDIUM VOLTAGE FUSELIVE FRONT TERMINATORMEDIUM VOLTAGE ELBOW
UTILITY METER
CAPACITORBATTERYLIGHTNING ARRESTERGROUND
AMPERE TEST POINT
VOLTAGE TEST POINT
GROUNDED WYE CONNECTION
DELTA CONNECTION
GROUND ROD
SOLID STATEMULTIFUNCTION METER
GROUND ROD AND GROUND WELL
IDENTIFICATION SYMBOLS MEDIUM VOLTAGE LOW VOLTAGE MISCELLANEOUS
GROUNDING
LUMINAIRES
SWITCHES/RECEPTACLES RACEWAY
LUMINAIRE, WALL MOUNTEDCONDUIT IDENTIFICATION
XXXX = CONDUIT NUMBER,
REFER TO CONDUIT SCHEDULE
APPROXIMATE DIMENSIONS
EQUIPMENT ENCLOSURE
MOV-ELBOW ARRESTERMEDIUM VOLTAGE CONTACTORMEDIUM VOLTAGE STARTER
KIRK KEY INTERLOCK
abc
FIRE ALARM CONTROL PANELFIRE ALARM PULL STATIONFIRE ALARM HORN/STROBE COMBINATIONFIRE ALARM STROBE
CONDUIT SIZE AND CONDUCTORS
W"C (WHERE INDICATED): W = CONDUIT TRADE SIZEU = NUMBER OF PARALLEL RUNS
IN FLOOR QUADRUPLEX RECEPTACLE
FIBER OPTIC CABLESFO/N
N = NUMBER OF INDIVIDUAL FIBERS
INDIVIDUAL CONDUCTORS
IN FLOOR DUPLEX RECEPTACLE
ENGINE-GENERATOR RATINGS AS INDICATED ON
THE DRAWINGS
CURRENT TRANSFORMER WITHSHORTING TERMINAL BLOCK
DISCONNECT SWITCH LOW VOLTAGE CIRCUIT BREAKER AUXILIARY OPERATOR * = S = SHUNT TRIP
= G = GROUND FAULT INTERRUPTER = V = SOLENOID KEY RELEASE
CIRCUIT BREAKER, MEDIUM VOLTAGE ANSI RELAY DEVICE
52 a
b
a
b
b
abcde
a
f
c
d
e
J
FACP
FFFF
ba
HP
~
G
cbade
a
b
a
b
ATP
SSM
VTP
*
b
B
A
CONDUIT IN SLAB
bc
a
DRAWOUT CONNECTION
fg
h
TRANSFORMER
a = DEVICE I.D. b = KVA RATINGc = NUMBER OF PHASESd = PRIMARY VOLTAGEe = SECONDARY VOLTAGEf,g= CONNECTION TYPE SYMBOLh = IMPEDANCE
PACKAGED EQUIPMENTLOAD RATING AS INDICATED
c d
POTENTIAL TRANSFORMER
a = QUANTITYb = RATIOc,d = CONNECTION TYPE SYMBOL 3 = QUANTITY X = SIZE OF CONDUCTORS(Ø) = DESIGNATES PHASE CONDUCTORS1 = QUANTITYY = SIZE OF CONDUCTORS(N) = DESIGNATES NEUTRAL CONDUCTORS1 = QUANTITYZ = SIZE OF CONDUCTORS(G) = DESIGNATES GROUND CONDUCTORS a
b
2 = DOUBLE POLE SWITCH
3 = THREE-WAY SWITCH
4 = FOUR-WAY SWITCH
K = KEY OPERATED SWITCH
F = SWITCH AND FUSESTAT HOLDER
P = SWITCH AND PILOT LIGHT
T = THERMOSTAT
D = DIMMER SWITCH
L = LOW VOLTAGE LIGHT SWITCH
M = MANUAL MOTOR STARTER
SINGLE POLE SWITCH
ab = DEVICE SWITCHED DESIGNATION
= CIRCUIT DESIGNATION
SWITCH AND SINGLE RECEPTACLE
DISCONNECT SWITCH
SMOKE DETECTOR
= TYPE = IONIZATION = PHOTOELECTRIC= DUCT DETECTOR
FIRE SPRINKLER F = FLOW SWITCH T = TAMPER SWITCH
MULTI CONDUCTOR CABLESK/2/C#16S
K (WHERE INDICATED) = NUMBER OF PAIRS2/C#16S = TWO CONDUCTOR, 16 GAUGE, TWISTED
SHIELDED PAIR
K/3/C#16S
K (WHERE INDICATED) = NUMBER OF TRIPLETS3/C#16S = THREE CONDUCTOR, 16 GAUGE, TWISTED
SHIELDED TRIPLETS
N = NUMBER OF CONDUCTORS IN THE CABLEX = SIZE OF CONDUCTORS
LOW VOLTAGE CIRCUIT BREAKER COMBINATION STARTERWITH CONTROL POWER TRANSFORMER
SPD SURGE PROTECTIVE
DEVICE
W"C-(3-X (Ø), 1-Y (N) & 1-Z (G))
EQUIP #
UNDERGROUND GROUND CABLE
3-X (Ø):1-Y (N)(WHERE INDICATED):1-Z (G)(WHERE INDICATED):U{3-X (Ø) & 1-X (G)}N/CX ba
ab
ba
ba
bababa
a
baba
PE
c
ab
a
B
K
LOAD BANK
da
XXXX
CONDUIT CAPCONDUIT TEE
ARE LABELED LEFT TO RIGHT OR TOP TO BOTTOM.
X
c
b a
BREAK AND CONTINUATION IN CONDUIT RUN
MEDIUM VOLTAGE TEE
FIRE ALARM
APPLIANCE RECEPTACLE
INDICATES KEYNOTE X XEQUIPMENT AND INSTRUMENT IDENTIFICATION #4/0 SDBC UNLESS OTHERWISE NOTED
UNLESS OTHERWISE NOTED, GROUPED CONDUITS
d
R H
3P= THREE POSITION SWITCH
OCCUPANCY SENSOR
c
b a
X
R G GO/NO-GO PANEL - SOLIDR GO/NO-GO PANEL - STROBE
c = TYPE
REFER TO ABBREVIATIONS LEGEND
OR IN DUCT BANKDUCT BANKSHOWN ON DUCT BANK SECTIONS
GO/NO-GO PANEL - STROBE AND HORN
= CIRCUIT DESIGNATION
= DEVICE SWITCHED FROM
= MOUNTING HEIGHT IN FEET TO
BOTTOM OF FIXTURE
FOR ALL OTHER DESIGNATIONS.
= REFERENCE LIGHTING CONTROL COMPONENT SCHEDULE= CIRCUIT DESIGNATION= DEVICE SWITCHED DESIGNATION= MOUNTING HEIGHT IN FEET TO BOTTOM OF SENSOR Xabc
= CIRCUIT DESIGNATION
b = DEVICE TYPE DESIGNATIONa
= CIRCUIT DESIGNATION
ba
= DISCONNECT TYPE
a = AMP RATING
= CIRCUIT DESIGNATION
ba
= MOUNTING HEIGHT
= CIRCUIT DESIGNATION
ba
= MOUNTING HEIGHT
dPIa
= CIRCUIT BREAKER NUMBER= FRAME SIZE= ANSI DEVICE FUNCTION= QUANTITY baab
TYPE AS NOTED
FUSED DISCONNECT SWITCH
MCP = MOTOR CIRCUIT PROTECTORTM = THERMAL MAGNETICSS = SOLID STATE
FRAME SIZE UNLESS INDICATED)
(AT = AMP TRIP)(AC = MCP CONTINUOUS RATING)
a = TYPEb = FRAME SIZE (MANUFACTURER TO DETERMINEc = NUMBER OF POLESd = TRIP SETTINGe = DESIGNATION f = INTERRUPTING RATING
A = TYPE, REFER TO DISCONNECT SCHEDULEb = FUSE RATINGB = TYPE, REFER TO DISCONNECT SCHEDULEa = CIRCUIT BREAKER DISCONNECT,b = STARTER TYPEc = NEMA STARTER SIZEd = OVERLOAD FULL LOAD AMPS AS NOTEDHP = HORSEPOWER RATINGa = RATED LOADb = UNIT(HP, KW, KVA) AS INDICATEDa = QUANTITYb = RATIOa = KVA/KWb = VOLTAGE/CONNECTIONc = PHASEd = WIREe = PF a
MOTOR STARTER/DRIVES:
b
c
VFD-6VFD-18 = 18-PULSE VFD
= 6-PULSE VFD
RVSSRVATa/B
= LINE REACTOR
PHF = PASSIVE HARMONIC FILTERLLLR = LOAD REACTORDV/DT = Dv/dt FILTERSWF = SINE WAVE FILTER a = DEVICE TYPE
bc
= REDUCED VOLTAGE SOLID
STATE STARTER
= REDUCED VOLTAGE AUTO
TRANSFORMER
= DEVICE WITH BYPASS
STARTER. REFER TOTHE SPECIFICATIONS
LINEAR FIXTURE
N = NETWORKED SINGLE OR
MULTIPLE SWITCH LOCATIONS
R = RED LIGHT
G = GREEN LIGHT
H = HORN
= INPUT OPTIONS= OUTPUT OPTIONS
VFD-RH = REDUCED HARMONIC VFD
PlotDate:12-JUL-202312:46:51PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 LEGEND
LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ELECTRICAL 00GE01
8660F10 8660F1000GE01.dgn
87 avates
JGB
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
ABBREVIATIONS
NOTES:
94 TRIPPING OR TRIP-FREE RELAY93 FIELD-CHANGING CONTACTOR 92 VOLTAGE AND POWER DIRECTIONAL RELAY 91 VOLTAGE DIRECTIONAL RELAY 90 REGULATING DEVICE 89 LINE SWITCH 88 AUXILIARY MOTOR OR MOTOR GENERATOR 87 DIFFERENTIAL PROTECTIVE RELAY 86 LOCKOUT RELAY 85 PILOT COMMUNICATIONS, CARRIER OR PILOT-WIRE RELAY84 OPERATING MECHANISM 83 AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY
P PHASE PROTECTION
V VOLTAGE
T TRANSFORMER PROTECTION
(RELAY COIL CONNECTED IN RESIDUAL CT CIRCUIT)
N GROUND FAULT PROTECTION
M MOTOR PROTECTION
L LINE PROTECTION
(RELAY CT IN TOROIDAL OR GROUND SENSOR TYPE)
GS GROUND FAULT PROTECTION
(RELAY CT IN A SYSTEM NEUTRAL CIRCUIT OR GENERATOR PROTECTION)
G GROUND FAULT PROTECTION
B BUS PROTECTION
A ALARM ONLY
ABBREVIATIONS
POWER DEVICE FUNCTION NUMBERS
POWER DEVICE FUNCTION NUMBERS
COMMONLY USED SUFFIX LETTERS APPLIED TO
SYM SYMMETRICALSWGR SWITCHGEAR SWBD SWITCHBOARD SW SWITCH STB SHORTING TERMINAL BLOCK SS SOLID STATE SPKR SPEAKER SPST SINGLE POLE SINGLE THROW SPDT SINGLE POLE DOUBLE THROW SPD SURGE PROTECTIVE DEVICE SP SINGLE POLESM SURFACE MOUNTED SLT SEALTIGHT LIQUIDTIGHT FLEXIBLE CONDUIT SFL SUB FEED LUGS SDBC SOFT DRAWN BARE COPPER SC SHORT CIRCUITSA SURGE ARRESTER S SHIELD / SHORT-TIME
RVSS REDUCED VOLTAGE SOLID STATERVNR REDUCED VOLTAGE NON-REVERSING RVAT REDUCED VOLTAGE AUTO TRANSFORMER RMS ROOT MEAN SQUARED RF RADIO FREQUENCYREV REVERSE RECPT RECEPTACLE RAC RIGID ALUMINUM CONDUIT PWR POWERPVC POLYVINYL CHLORIDE RIGID PLASTIC CONDUIT PT POTENTIAL TRANSFORMERPRI PRIMARY PPX POWER PANEL NO. X PNL PANEL PH PHASE PFR PHASE FAILURE RELAY PFCC POWER FACTOR CORRECTION CAPACITORPF POWER FACTOR PE PHOTOCELL PCM PROCESS CONTROL MODULEPCS PVC COATED GALVANIZED STEEL CONDUIT PB PUSHBUTTON / PULL BOX PA PUBLIC ADDRESS P POLE
OL OVERLOAD RELAY OH OVERHEAD O OPEN OR OPENED
NP NAMEPLATE NO NORMALLY OPEN NL NIGHT LIGHT NFC NONMETALLIC FLEXIBLE CONDUIT NEC NATIONAL ELECTRICAL CODE NC NORMALLY CLOSED N NEUTRAL MW MEGAWATT MVS MEDIUM VOLTAGE SWITCHMVA MEGAVOLT-AMPERES MV MEGAVOLT MTS MANUAL TRANSFER SWITCH MTR-X MOTOR NO. X MTO MANUAL THROW OVER MSP MOTOR STARTING PANEL MS-X MOTOR STARTER NO. X MPR MOTOR PROTECTION RELAYMOV METAL OXIDE VARISTORMOD MOTOR OPERATED DAMPER MLO MAIN LUGS ONLY MH MANHOLE / MOUNTING HEIGHTMCP MOTOR CIRCUIT PROTECTOR MCC - X MOTOR CONTROL CENTER NO. X MCA MOTOR CIRCUIT AMPSMA MILLIAMPERE M-X MOTOR CONTROLLER NO. X LVL LEVELLV LOW VOLTAGE LTG LIGHTING LP - X LIGHTING PANEL NO. X LP LIGHT POLE LL LEAD-LAG LOAD REACTOR LCP- X LOCAL CONTROL PANEL NO. X LC LIGHTING CONTACT OR LBL LABEL LA LIGHTNING ARRESTOR L-G LINE-GROUND L-B LINE-BUS L LONG-TIME KWH KILOWATT HOURKWD KILOWATT DEMAND KW KILOWATT KVAR KILOVAR (REACTANCE) KVA KILOVOLT AMPERE KV KILOVOLT KA KILOAMP K KEY INTERLOCK
J JUNCTION BOX
82 DC LOAD MEASURING RECLOSING RELAY81 FREQUENCY RELAY 80 FLOW SWITCH 79 AC RECLOSING RELAY 78 PHASE-ANGLE MEASURING RELAY 77 TELEMETERING DEVICE76 DC OVERCURRENT RELAY 75 POSITION CHANGING MECHANISM 74 ALARM RELAY 73 LOAD-RESISTOR CONTACTOR 72 DC CIRCUIT BREAKER 71 LIQUID LEVEL SWITCH 70 RHEOSTAT 69 PERMISSIVE CONTROL DEVICE 68 BLOCKING OR OUT OF STEP RELAY 67 AC DIRECTIONAL OVERCURRENT RELAY 66 NOTCHING OR JOGGING DEVICE 65 GOVERNOR 64 GROUND DETECTOR RELAY 63 PRESSURE SWITCH 62 TIME-DELAY STOPPING OR OPENING RELAY 61 DENSITY SWITCH OR SENSOR60 VOLTAGE OR CURRENT BALANCE RELAY 59 OVERVOLTAGE RELAY 58 RECTIFICATION FAILURE RELAY 57 SHORT-CIRCUITING OR GROUNDING DEVICE 56 FIELD APPLICATION RELAY 55 POWER FACTOR RELAY 54 TURNING GEAR ENGAGING DEVICE53 FIELD EXCITATION RELAY52 AC CIRCUIT BREAKER 51 AC TIME OVERCURRENT RELAY 50 INSTANTANEOUS OVERCURRENT RELAY 49 MACHINE OR TRANSFORMER THERMAL RELAY 48 INCOMPLETE SEQUENCE RELAY 47 PHASE-BALANCE OR PHASE-SEQUENCE VOLTAGE RELAY 46 REVERSE-PHASE OR BALANCE CURRENT RELAY 45 ABNORMAL ATMOSPHERIC CONDITION MONITOR 44 UNIT SEQUENCE STARTING RELAY 43 MANUAL TRANSFER OR SELECTOR DEVICE 42 RUNNING CIRCUIT BREAKER 41 FIELD CIRCUIT BREAKER 40 FIELD RELAY 39 MECHANICAL CONDITION MONITOR 38 BEARING PROTECTIVE DEVICE 37 UNDERCURRENT OR UNDERPOWER RELAY 36 POLARITY DEVICE35 BRUSH-OPERATING OR SLIP-RING SHORT-CIRCUITING DEVICE 34 MASTER SEQUENCE DEVICE 33 POSITION SWITCH32 DIRECTIONAL POWER RELAY 31 SEPARATE EXCITATION DEVICE 30 ANNUNCIATOR RELAY 29 ISOLATING CONTACTOR 28 FLAME DETECTOR 27N GROUND FAULT UNDERVOLTAGE RELAY 27 UNDERVOLTAGE RELAY 26 APPARATUS THERMAL DEVICE 25 SYNCHRONIZING OR SYNCHRONISM-CHECK DEVICE 24 VOLTS PER HERTZ RELAY 23 TEMPERATURE CONTROL DEVICE 22 EQUALIZER CIRCUIT BREAKER 21 DISTANCE RELAY 20 ELECTRICALLY OPERATED VALVE 19 STARTING-TO-RUNNING TRANSITION CONTACTOR 18 ACCELERATING OR DECELERATING DEVICE 17 SHUNTING OR DISCHARGE SWITCH16 DATA COMMUNICATIONS DEVICE15 SPEED OR FREQUENCY MATCHING DEVICE 14 UNDER-SPEED DEVICE 13 SYNCHRONOUS-SPEED DEVICE 12 OVER-SPEED DEVICE 11 MULTIFUNCTION DEVICE10 UNIT SEQUENCE SWITCH 9 REVERSING DEVICE
8 CONTROL POWER DISCONNECTING DEVICE
7 ANODE CIRCUIT BREAKER
6 STARTING CIRCUIT BREAKER
5 STOPPING DEVICE
4 MASTER CONTACTOR
3 CHECKING OR INTERLOCKING RELAY
2 TIME-DELAY STARTING OR CLOSING RELAY
1 MASTER ELEMENT
TCM - TRIP CIRCUIT MONITOR
SER - SEQUENCE OF EVENTS RECORDER
RTU - REMOTE TELEMETRY UNIT/REMOTE TERMINAL UNITRIO - REMOTE I/O DEVICE
PQM - POWER QUALITY MONITORPMU - PHASOR MEASUREMENT UNITPDC - PHASOR DATA CONCENTRATOR
MET - SUBSTATION METERING
LGC - SCHEME LOGIC
HST - HISTORIANHMI - HUMAN MACHINE INTERFACEHIZ - HIGH IMPEDANCE FAULT DETECTOR
ENV - ENVIRONMENTAL DATA
DFR - DIGITAL FAULT RECORDERDDR - DYNAMIC DISTURBANCE RECORDER
CLK - CLOCK OR TIMING SOURCE
AFD - ARC FLASH DETECTOR
1. REFER TO SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL ABBREVIATIONS.
INTERCOM INTERCOMMUNICATION INT INTERLOCK INST INSTANTANEOUS IMC INTERMEDIATE METAL CONDUIT IJB INSTRUMENT JUNCTION BOXIC INTERRUPTING CAPACITYI INSTANTANEOUS / INTERMITTENT LOAD
HZ HERTZHVAC HEATING/VENTILATION/AIR CONDITIONING HV HIGH VOLTAGE HSTAT HUMIDISTAT HR HOUR HPS HIGH PRESSURE SODIUM HP HORSEPOWER HF HIGH FREQUENCY H HOT-LEG
GFR GROUND FAULT RELAY GFI GROUND FAULT INTERRUPTER (BREAKER) GFCI GROUND FAULT CIRCUIT INTERRUPTER (RECEPTACLE) GRC GALVANIZED STEEL RIGID CONDUIT GEN GENERATORG GROUND / EQUIPMENT GROUND / GROUND FAULT
FWD FORWARDFVR FULL VOLTAGE REVERSING FVNR FULL VOLTAGE NON-REVERSING FU SW FUSED SWITCHFU FUSEFREQ FREQUENCY FRC FIBERGLASS RIGID CONDUIT FO FIBER OPTICFLX FLEXIBLE CONDUIT FLA FULL LOAD AMPS FDR FEEDERFACP FIRE ALARM CONTROL PANEL FA FIRE ALARMF SUB-FED
ETM ELAPSED TIME METEREP EXPLOSION PROOFENT ELECTRICAL NON-METALLIC TUBINGENG ENGINEENCL ENCLOSURE EMT ELECTRICAL METALLIC TUBING EM EMERGENCYE/G EMERGENCY GENERATOR DS DOOR SWITCH DPST DOUBLE POLE SINGLE THROW DPDT DOUBLE POLE DOUBLE THROW DM DEMAND METERDISC DISCONNECT SWITCH DEMO DEMOLITIONDCU - X DISTRIBUTED CONTROL UNIT NO. X DCS DISTRIBUTED CONTROL SYSTEM DC DIRECT CURRENT
CW CLOCKWISE / COOL WHITE CV CONTROL VALVE CT CURRENT TRANSFORMER CS CONTROL SWITCH CR CONTROLLED RECEPTACLECPT CONTROL POWER TRANSFORMER COMM COMMUNICATION COM COMMON COAX COAXIAL CABLE CKT CIRCUIT CCW COUNTER CLOCKWISECCTV CLOSED CIRCUIT TELEVISION CB CIRCUIT BREAKER C CONDUIT / CONTINUOUS LOAD
BRF BELOW RAISED FLOOR BKR BREAKER BHP BRAKE HORSEPOWER BFG BELOW FINISHED GRADE BAT BATTERY B BELL
AWG AMERICAN WIRE GAGEAUX AUXILIARY AUTO XFMR AUTOMATIC TRANSFORMER ATS AUTOMATIC TRANSFER SWITCH ATP AMMETER TEST POINT ATO AUTOMATIC THROW OVER AT AMP TRIP ASYM ASYMMETRICAL AS AMMETER SWITCH ARM ARMORED CABLE APU AUXILIARY POWER UNITANT ANTENNA ANN ANNUNCIATOR AM AMMETERAIC AMP INTERRUPTING CAPACITY AFC AUTOMATIC FREQUENCY CONTROL AF AMP FRAME ACTR ACTUATOR ACK ACKNOWLEDGE AC ALTERNATING CURRENT ABS ABSOLUTEA AMP XFMR TRANSFORMER WP WEATHER PROOF WT WATER TIGHT W WATT / WEST VTP VOLTAGE TEST POINT VT VOLTAGE TRANSFORMER VS VOLTAGE SWITCHVR VOLTAGE REGULATOR VP VAPORPROOF VM VOLTMETERVHF VERY HIGH FREQUENCY VFD VARIABLE FREQUENCY DRIVE VCP VENDOR CONTROL PANELVAR VARMETERVA VOLT AMPERE V VOLT UVR UNDER VOLTAGE RELAYUPS UNINTERRUPTIBLE POWER SUPPLY UNG UNGROUNDEDUHF ULTRA HIGH FREQUENCY TSTAT THERMOSTATTS2W TWO SPEED SEPARATE WINDING TS1W TWO SPEED CONSEQUENT POLE, ONE WINDING TS TEMPERATURE SWITCH TP TWISTED PAIR TM THERMAL MAGNETIC TJB TERMINAL JUNCTION BOX TERM TERMINAL TENV TOTALLY ENCLOSED NON-VENTILATED TEFC TOTALLY ENCLOSED FAN COOLED TE TOTALLY ENCLOSED TD TEMPERATURE DETECTOR RELAY TC THERMOCOUPLE / TIME CLOCK / TRAY CABLE TB - X TERMINAL BLOCK - UNIT X TACH TACHOMETER PlotDate:12-JUL-202312:51:03PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ELECTRICAL 00GE02
ABBREVIATIONS
8660F10 8660F1000GE02.dgn
bshepard
JGB
88
HH-1
HH-2
BUILDING
ELECTRICAL
PUMP STATION
RECYCLED WATER
HH-4
HH-3
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
SS
W
SS
PlotDate:12-JUL-202312:50:48PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 01E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1001E01.dgn
0 20' 40' 80'
A
02E01
A
02E01
A
02E01
A
99E01
C
99E03
B
99E02
D
99E04
JGB
G
99E14
F
99E13
E
99E12
TYP
EM001
TYP
EM001
1 # KEY NOTES:
STORAGE TANK
RECYCLED WATER
WTP PUMP STATION AND STORAGE SITE PLAN
TREATMENT BLDGEXISTING WATER
TYP
EM002
2 CROSSING UNDER THE DUCT BANK.REDUCED DEPTH DUCT BANK TO ACCOMMODATE YARD PIPE
2. DUCT BANK SEGMENT BETWEEN HH-2 AND HH-3 SHALL BE BUILT AS FINISHED GRADE.DUCT BANK AT THIS LOCATION SHALL NOT EXCEED 3'-6" BELOW
1. DUCT BANK CROSSES OVER YARD PIPE. DEPTH FOR BOTTOM OF B
02E01
89 obonafoux
MV (E)
MV (E)
LV (E)
MV (E)
STRUCTURE
DE-CHLORINATION
FACILITY
CHLORINATION
FACILITYDE-WATERINGSLUDGE
PUMP STATIONPROPOSED PAU
HH-20
HH-21
BUILDINGPOWER GENERATION
STATIONPUMPCAROUSEL
MV (N)
COUED-4
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
.175 0
5 7
2 5
7 2
5 7
2 5
7 2
5 7
4 5
7 4
5 7
4 5
7 4
SD
5 7
6 5
7 6
5 7
6 5
7 6
5 7
6 SD
WV
WV
WV
WV
5 7
8 578
5 7
8 5
7 8
WV
WV
WV
WV
WV
SS
WV
SS
WV
WV
SS
SS
SS
WV
WV
SS
PlotDate:12-JUL-202312:49:18PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 01E02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1001E02.dgn
A
12E01
A
80E01
85E01
A
70E01
A
A
91E01
A
87E01
89E02
B
60E01
A
0 10' 20' 30' 60'
B
91E01
WWTP AND STORAGE POND
BLDG.
EQUIP.
DAFT
FACILITY
AWT
I
02E01
J
02E02
K
02E02
H
02E01
89E01
A
M
02E03
M
02E03 M
02E03
L
02E02
P
02E03
1 2
1 JGB
01E03
01E03
Z
01E03
2 PED-983
3 Z
01E03
2 avates
R
02E03
FIT-88101
FIT-88102
4 4
L-88-101
S-88-101
L-88-102
S-88-102
5 Q
02E03
#
GENERAL NOTES:
KEY NOTES:
DETAIL EM015/TYP.
5. INSTALL CONDUITS UNDERGROUND ACCORDING TO TYPICAL
TYPICAL DETAIL EM104/TYP.
4. INSTALL CONDUITS ADJACENT TO HAND RAILS ACCORDING TO EXACT VAULT LOCATION WITH COUED.16210 FOR UTILITY CONSTRUCTION DETAILS. COORDINATE THE CONSTRUCTION DETAIL. REFER TO SPECIFICATION SETCTION UKIAH ELECTRIC DEPARTMENT (COUED) MV VAULT
3. CONTRACTOR TO PROVIDE MV VAULT ACCORDING TO CITY OF
WITH CITY OF UKIAH ELECTRIC DEPARTMENT (COUED).COORDINATE EXACT UNDERGROUND 12KV CONDUIT ROUTING APPROXIMATE. CONTRACTOR SHALL MEET ON SITE AND TRENCH SECTION. NEW 12KV ROUTING PROVIDED HERE IS
2. INSTALL UNDERGROUND 12KV CONDUITS ACCORDING TO
STRUCTURES OR UNDERGROUND EQUIPEMENT.NEEDED TO ACCOMMODATE CONSTRUCTION OF NEW DEMOLISH EXISTING UNDERGROUND 12KV CONDUITS WHERE TRF-3E AND PEDESTAL PD-983 ARE REMOVED BY COUED,
1. AFTER EXISTING 12KV CONDUCTORS BETWEEN TRANSFORMER
SHALL VERIFY BEFORE EXCAVATION FOR NEW INSTALLATION.MAY NOT REFLECT ACTUAL FIELD CONDITION. CONTRACTOR
1. EXISTING UNDERGROUND DUCT BANK AND CONDUIT ROUTING
PARTIAL SITE PLAN 90
HH-13
MH-12
HH-11
HH-10
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:54:36PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 01E03
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1001E03.dgn
02E02
02E01
H2
02E01
H1
02E02
I1
02E02
I2
02E02
J2
02E02
K1
02E02
J2
02E02
K2
02E02
J1
02E02
K
02E02
J
02E01
H
02E01
I
1 JGB
1 01E02 1/4" = 1'-0"
8660F1001E0101
2 01E02 1/4" = 1'-0"
8660F1001E0101
J1
J 02E02
DWG 01E02
CONTINUED ON
DWG01E02
CONTINUEDON
DWG01E02
CONTINUEDON
DWG 01E02
CONTINUED ON
DWG01E02
CONTINUEDON
# KEY NOTES:
avates
WWTP AND STORAGE POND SITE
PLAN DETAILS AND TRENCH SECTION
3 4
5 2
Z
01E02 NO SCALE
8660F1003E001
6 UNDERGROUND UTILITIES SHALL BE MINIMUM 12".
6. MINIMUM CLEARANCE BETWEEN 12KV CONDUITS AND OTHER
DRIVEWAY.
5. 2" CONCRETE COVER AT 12" BFG WHERE TRENCH IS UNDER 4. 4" CONDUIT FOR COUED 12KV LINE.3. 4" CONDUIT FOR COUED 12KV SPARE.
FILL. PROVIDED SECTION IS SCHEMATIC ONLY.SPCIFICATION SECTION 16210 FOR TRENCH DEPTH, SPACING AND
2. REFER TO UTILITY CONSTRUCTION DETAILS PROVIDED IN
DUCT BANK DRAINAGE.
1. SLOPE DUCT BANKS TOWARD THIS MANHOLE TO PROVIDE PROPER 91
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
GENERAL NOTES:
EM001/TYP UNLESS OTHERWISE INDICATED.
1. CONSTRUCT DUCT BANK IN ACCORDANCE WITH DETAIL
X-2054
(2")
X-2100
(2")
X-2101
(2")
X-3100
(2")
X-3104
(2")
X-3200
(2")
X-2021
(2")
X-2031
(2")
X-2041
(2")
X-2051
(2")
X-2052
(2")
X-2053
(2")
S-3102
(2")
N-3100
(2")
X-1500
(2")
X-1501
(2")
X-1502
(2")
X-2011
(2")
C-2015
(2")
S-2011
(2")
S-2021
(2")
S-2031
(2")
S-2041
(2")
S-2431
(2")
X-3100
(2")
X-3104
(2")
X-3200
(2")
C-3102
(2")
X-3101
(2")
S-3101
(2")
L-3102
(2")
L-3200
(2")
C-3105
(2")
C-2025
(2")
C-2035
(2")
C-2045
(2")
N-3100
(2")
X-1500
(2")
X-1501
(2")
X-1502
(2")
X-0010
(4")
X-0011
(4")
P-0010
(4")
P-0011
(4")
X-0010
(4")
X-0011
(4")
P-0010
(4")
P-0011
(4") P-2012
(2")
P-2022
(2")
P-2032
(2")
P-2042
(2")
L-2100
(2")
L-2431
(2")
L-3102
(2")
L-3200
(2")
C-3105
(2")
S-3102
(2")
Width: 3'-0"Height: 1'-7"
Width: 3'-0"Height: 2'-4"
Width: 3'-1"Height: 3'-3"
Width: 2'-4"Height: 2'-2"
A DUCT BANK SECTION B DUCT BANK SECTION C DUCT BANK SECTION D DUCT BANK SECTION 01E01, 01E01, 01E01, 99E01, 99E02, 99E12 01E01 99E02, 99E03, 99E12, 99E13 99E03, 99E13, 99E14 X-3102
(2")
X-3103
(2")
X-3100
(2")
C-3005
(2")
S-3200
(2")
N-3100
(2")
S-3200
(2")
X-3102
(2")
X-3103
(2")
X-91-100
(2")
X-91-102
(2")
C-91-110
(2")
X-91-100
(2")
L-3100
(2")
L-3101
(2")
L-3200
(2")
L-3101
(2")
L-3200
(2")
C-3005
(2")
P-91-101
(2")
L-91-100
(2")
C-91-110
(2")
P-91-101
(2")
L-91-100
(2")
X-91-102
(2")
Width: 1'-11"Height: 2'-2"
Width: 1'-11"Height: 1'-9"
Width: 1'-11"Height: 1'-9"
Width: 1'-7"Height: 1'-9"
Width: 1'-2"Height: 1'-5"
E DUCT BANK SECTION F DUCT BANK SECTION H DUCT BANK SECTION H1 DUCT BANK SECTION H2 DUCT BANK SECTION 99E14 99E14 01E02, 01E03, 91E01, 91E01 01E03 01E03
PlotDate:12-JUL-202312:51:19PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 02E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
8660F10 8660F1002E01.dgn
DUCT BANK SECTIONS 1
bshepard
92
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
GENERAL NOTES:
EM001/TYP UNLESS OTHERWISE INDICATED.
1. CONSTRUCT DUCT BANK IN ACCORDANCE WITH DETAIL
X-89-100
(2")
X-89-101
(2")
X-89-120
(2")
X-89-125
(2")
X-89-100
(2")
X-89-120
(2")
X-89-110
(2")
X-89-112
(2")
S-89-102
(2")
N-60-112
(2")
L-89-111
(2")
C-89-120
(2")
S-89-101
(2")
N-60-111
(2")
P-89-131
(2")
L-89-111
(2")
C-89-120
(2")
X-89-101
(2")
X-89-125
(2")
P-91-101
(2")
L-89-112
(2")
C-89-120
(2")
C-91-111
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-131
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
S-89-101
(2")
N-60-111
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-132
(2")
Width: 2'-4"Height: 2'-2"
Width: 1'-11"Height: 2'-2"
Width: 1'-7"Height: 1'-9"
Width: 2'-4"Height: 2'-2"
I DUCT BANK SECTION I1 DUCT BANK SECTION I2 DUCT BANK SECTION J DUCT BANK SECTION NO MATCHING REF DWGS FOUND 01E03 01E03 01E02, 01E03, 01E03 X-89-110
(2")
X-89-112
(2")
X-89-111
(2")
X-89-113
(2")
S-89-102
(2")
N-60-113
(2")
X-89-111
(2")
X-89-113
(2")
P-91-101
(2")
L-89-112
(2")
C-89-120
(2")
C-91-111
(2")
P-91-101
(2")
L-89-113
(2")
C-89-120
(2")
C-91-111
(2")
P-91-101
(2")
L-89-113
(2")
C-89-120
(2")
C-91-111
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-132
(2")
S-89-102
(2")
N-60-112
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-133
(2")
P-89-101
(2")
P-89-111
(2")
P-89-121
(2")
P-89-133
(2")
S-89-102
(2")
N-60-113
(2")
Width: 2'-4"Height: 2'-2"
Width: 1'-7"Height: 1'-5"
Width: 2'-4"Height: 2'-2"
Width: 2'-4"Height: 2'-2"
Width: 1'-7"Height: 1'-5"
J1 DUCT BANK SECTION J2 DUCT BANK SECTION K DUCT BANK SECTION K1 DUCT BANK SECTION K2 DUCT BANK SECTION 01E03, 01E03 01E03, 01E03 01E02, 01E03, 70E01 01E03 01E03 PlotDate:12-JUL-202312:52:31PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
AH
NS
ELECTRICAL
DUCT BANK SECTIONS 2
8660F10 8660F1002E02.dgn
02E02
JGB
bshepard
93
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
GENERAL NOTES:
EM001/TYP UNLESS OTHERWISE INDICATED.
1. CONSTRUCT DUCT BANK IN ACCORDANCE WITH DETAIL
N-60-110
(2")
X-60-100
(2")
P-60-120
(2")
L-60-111
(2")
X-60-105
(2")
S-80-101
(2")
X-80-100
(2")
X-80-101
(2")
P-87-101
(2")
C-87-101
(2")
S-87-100
(2")
P-87-112
(2")
C-87-110
(2")
S-88-105
(2")
Width: 1'-11"Height: 1'-9"
Width: 1'-11"Height: 1'-5"
Width: 1'-11"Height: 1'-5"
Width: 1'-11"Height: 1'-5"
L DUCT BANK SECTION M DUCT BANK SECTION P DUCT BANK SECTION Q DUCT BANK SECTION NO MATCHING REF DWGS FOUND 01E02, 01E02, 01E02, 70E01, 80E01 01E02, 87E01 01E02, 87E01 C-87-110
(2")
S-87-100
(2")
S-88-105
(2")
P-87-101
(2")
P-87-112
(2")
C-87-101
(2")
Width: 1'-11"Height: 1'-9"
R DUCT BANK SECTION
01E02, 85E03
PlotDate:12-JUL-202312:53:16PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
AH
NS
ELECTRICAL
DUCT BANK SECTIONS 3
8660F10 8660F1002E03.dgn
02E03
JGB
bshepard
94
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
~
G
TM
2000 AT
3P
SSM
SPD
3 PHASE750 KVA
SPARE
TM
1200 AT
3P
1200 AF
65 KAIC
TM
3P
30 AT 65 KAIC
TM
1200 AT
3P
1200 AF
65 KAIC
SPARE
TM
3P
65 KAIC
TM
400 AT
3P
65 KAIC
TM
200 AT
3P
65 KAIC
TM
225 AT
3P
65 KAIC
VFD
12000 V480/277 V
65 KAIC
2000 AF
3 PHASE4 WIREPR 0.8480/277 V655 KW
UTILITY
TO EXISTING
1200 AMPS480 V, 3 PHASE, 3 WIRE
30 AT
ATS-E
MCC-N
MCC-E
VFD-XFR
MCC-XFR
1 MCC-RW
1 1
2 SWBD-A
XFMR-A
GEN-A
2000 AMPS, 480/277 V, 3 PHASE, 4 WIRE, 60 HZ, 65 KASC RMS 1200 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS 600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 42 KASC RMS 600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS TM
200 AT
3P
42 KAIC
TM
500 AT
3P
65 KAIC
600 AF
500 AT
3P
65 KAIC
600 AF SS-LSIG
600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS
SWBD-RWPS
PNL-RWPS
480 V, 3 PHASE, 3 WIRE600 AMPS65 KASC RMS
3 1200 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS 4 4
SHALL FIELD VERIFY WHERE NEEDED.AND MAY NOT REFLECT EXACT FIELD CONDITION. CONTRACTOR
1. EXISTING EQUIPMENT INFORMATION ARE FROM RECORD DRAWINGS #
4. EXISTING BREAKERS ARE 100% RATED BREAKER.3. EXISTING SWITCHBOARD IS WESTINGHOUSE, SERIES POW-R-LINE.
TERMINATE NEW PANEL FEEDER CABLES ON NEW LUGS.
2. INSTALL NEW LUGS ON EXISTING MCC HORIZONTAL BUS AND
NUMBER IS 4713A99H12.
1. EXISTING MCC IS WESTINGHOUSE, SERIES 2100. MCC SERIAL GENERAL NOTES:
KEY NOTES:
PlotDate:12-JUL-202312:47:00PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1003E01.dgn
JGB
WTP MODIFIED OVERALL ONE-LINE DIAGRAM
95 avates
30" 25" 25"
90"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
1 2A2B2CVFD-99412 2DRECYCLED
WATER PUMP #2VFD-99413RECYCLEDWATER PUMP #3VFD-99414RECYCLEDWATER PUMP #4XFMR-RWPS-LRWPS LIGHTINGTRANSFORMERSPACESPACESPD
MAINBREAKERINCOMINGLINE
2E1A- 1B- 1C- 1D- 1E- SPACE SPACE SPACE SPACE
1F1G1H1I1J1K- VFD-99415 RECYCLED WATER PUMP #5 (FUTURE) 2 ABCDE
JIHGFEDCBAK
WATER PUMP #1RECYCLEDVFD-99411
3/4" = 1'-0"
8660F1003E0611
3/4" = 1'-0"
8660F1003E0611
PQM-99400METERINGPOWER
PlotDate:12-JUL-202312:47:22PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1003E02.dgn
SWBD-RWPS ELEVATION
JGB
96 avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
600:5
3 500 AT
3P 3P
TM
3 PHASE30 KVA
SPD
LR
75 3P
TM65 KAIC
3-#1/0(Ø)&1-#6(G)
600 AF
65 KAICSS-LSIG
RECYCLED WATER
PUMP #1
VFD-RH
150 AT
150 AF
LR
75 3P
TM65 KAIC
3-#1/0(Ø)&1-#6(G)
RECYCLED WATER
PUMP #2
VFD-RH
150 AT
150 AF
LR
75 3P
TM65 KAIC
3-#1/0(Ø)&1-#6(G)
RECYCLED WATER
PUMP #3
VFD-RH
150 AT
150 AF
LR
75 3P
TM65 KAIC
3-#1/0(Ø)&1-#6(G)
RECYCLED WATER
PUMP #4
VFD-RH
150 AT
150 AF
90 AT
480 V208/120 V
65 KAIC
3-#3(Ø)&1-#8(G)
3-#3(Ø),1-#3(N)&1-#8(G)
RECYCLED WATER P.S.
LIGHTNING PANELBOARD
VFD-99411
PMP-99411
VFD-99412 VFD-99413 VFD-99414
PMP-99412 PMP-99413 PMP-99414 PNL-RWPS-L
XFMR-RWPS-L
MAIN BREAKER
FROM PNL-RWPS
LR
75 3P
TM
150 AT
RECYCLED WATER
PUMP #5
(FUTURE)
VFD-99415
PMP-99415
VFD-RH
150 AF
65 KAIC
SWBD-RWPS, 600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65KASC RMS 2{3-500KCMIL(Ø)&1-#2/0(G)}
SSM
PlotDate:12-JUL-202312:47:30PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E03
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1003E03.dgn
SWBD-RWPS ONE-LINE DIAGRAM
JGB
avates
1 06N01
1 06N01
1 06N01
1 06N01
1 06N01
97
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PED-325
TFR-3E
PED-983
TFR-2E TFR-1E
PED-326
(CITY OF UKIAH)
UTILITY 12KV
TFR-1
SWR12101
~
G
~
G
1 1
1 STANDBY GENERATOR
GEN12151 GEN12151
(FUTURE)
STANDBY GENERATOR 2
1 2 1
SWB22281 SWB22282
SWB31281 SWB31282
SWB40481
SWB70281
SWB40482
SWB70282
SWB50481 SWB50482
MCC12191 MCC12192
MCC-C
MCC-A
MCC-D
SPACE SPACE
PUMPING SUBSTATION
TRICKLING FILTER
SUBSTATION
HEADWORKS
SUBSTATION
AERATION BLOWER
SUBSTATION
DAFT
SUBSTATION
CLARIFIERS
SECONDARY
SUBSTATION
GENERATION
POWER
SPARE SPARE
52-A5 52-A4 52-A3 52-A2 52-A1
52-AT
52-B1 52-B2 52-B3 52-B4 52-B5 52-B6 52-B7
52-M 52-G1 52-G2
TFR-1E
PHASE 1-3 PUMP STATION CAROUSEL PUMP STATION MAINTENANCE BUILDING ANIMAL SHELTER 3 BUILDING
MECHANICAL
FACILITY
AWT
FACILITY
DEWATERING
SLUDGE
SHALL FIELD VERIFY WHERE NEEDED.AND MAY NOT REFLECT EXACT FIELD CONDITION. CONTRACTOR
2. EXISTING EQUIPMENT INFORMATION ARE FROM RECORD DRAWINGS DEPARTMENT (COUED).
1. ELECTRIC UTILITY COMPANY IS CITY OF UKIAH ELECTRIC
#
COMPLETED BY THE CONTRACTOR.AFTER INSTALLATION OF NEW UNDERGROUND 12KV CONDUITS IS 12KV CONDUCTORS INSIDE NEW UNDERGROUND 12KV CONDUITS
3. CITY OF UKIAH ELECTRIC DEPARTMENT (COUED) TO INSTALL NEW AND EXISTING 12KV LINE ROUTING.SITE PLAN DRAWING 01E02 FOR TRF-3E AND PD-983 LOCATIONS, DURATION AND ACCESS FOR THIS SCOPE WITH COUED. REFER TO PEDESTAL PD-983. CONTRACTOR SHALL COORDINATE THE TIMING, EXISTING 12KV CONDUCTORS BETWEEN TRANSFORMER TRF-3E AND
2. CITY OF UKIAH ELECTRIC DEPARTMENT (COUED) TO REMOVE
(COUED).IS OWNED AND OPERATED BY CITY OF UKIAH ELECTRIC UTILITY
1. EXISTING 12KV UTILITY LINE FOR WASTEWATER TREATMENT PLANT GENERAL NOTES:
KEY NOTES:
PlotDate:12-JUL-202312:54:55PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E04
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
BLS
ELECTRICAL
8660F10 8660F1003E04.dgn
JGB
ONE-LINE DIAGRAM
WWTP MODIFIED OVERALL
98 avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
#
GENERAL NOTES:
KEY NOTES:
3P
TM
40 LL
LR
VFD-6
3P
MCP
FVNR
40 3P
MCP
FVNR
40 TM
3P
200 AMPS, 480/277 V, 3 PHASE, 4 WIRE, 60 HZ, 65 KASC RMS
EFFLUENT
PUMP NO. 3
3 EFFLUENT
PUMP NO. 2
EFFLUENT
PUMP NO. 1
3 20 AT
? ?
EDR-99101 EDR-99102
TM
2P
20 AT
1 PHASE1 KVA480V120/240V
FIT-99105
VALVE NO. 1
CONTROL
FLOW
VALVE NO. 2
CONTROL
FLOW
METER
VAULT FLOW
METERING
3 PHASE12KV480/277V150 KVA
1 2
1 TRF-3E
(ADMIN BUILDING)
TO PEDESTAL 983
(RECYCLE PUMP STATION)
T2076
TO TRANSFORMER
NOA
NOB
3 POLE200 AMAIN DISCONNECT SWITCH
MOTOR CONTROL CABINET
5 3 4
TRANSFORMER
6 7
FOR ADDITIONAL DEMOLITION REQUIREMENTS.REMAIN IN PLACE. REFER TO DRAWING 00D01 GENERAL NOTES UNDERGROUND AND CONCRETE EMBEDDED CONDUITS SHALL WHICH ARE MARKED ON THIS DRAWING FOR DEMOLITION.
2. DEMOLISH EXPOSED CONDUIT, AND ALL CABLES FOR CIRCUITS (COUED).
1. ELECTRIC UTILITY IS CITY OF UKIAH ELECTRIC DEPARTMENT 8. SEE DRAWING 03E04 FOR DEMO NOTES.
RECONNECTED TO PNL70271.
7. EXISTING FLOW METER DISCONNECT SWITCH TO BE
MCC70293.
6. EXISTING DISCONNECT SWITCH TO BE RECONNECTED TO
MCC70292, AND REDESIGNED AS A CAROUSEL PUMP.
5. EXISTING PUMP WITH NEW MOTOR TO BE RECONNECTED TO
MCC70291, AND REDESIGNATED AS A CAROUSEL PUMP.
4. EXISTING PUMP WITH NEW MOTOR TO BE RECONNECTED TO
MOTOR REQUIREMENTS.PUMP. PROTECT PUMP IN PLACE. REFER TO SPEC 11312D FOR
3. REMOVE EXISTING PUMP MOTOR FROM EXISTING EFFLUENT
01140.PROCEDURE SHOULD COMPLY WITH SPECIFICATION SECTION POSITION. IF POWER SHUT DOWN IS REQUIRED, THE (COUED), AND PLACE BOTH A AND B SWITCHES IN OPEN PLANT OPERATOR AND CITY OF UKIAH ELECTRIC DEPARTMENT IN PLACE. DEMOLISH SECONDARY CONDUCTORS. VERIFY WITH
2. PROTECT CAROUSEL PUMP STATION EXISTING TRANSFORMER
DEPARTMENT (COUED).PLANT. IS OWNED AND OPERATED BY CITY OF UKIAH ELECTRIC 8 1. EXISTING 12KV UTILITY LINE FOR WASTEWATER TREATMENT PlotDate:12-JUL-202312:52:15PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E05
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
SMB
ELECTRICAL
8660F10 8660F1003E05.dgn
JGB
DEMO ONE-LINE DIAGRAM
CAROUSEL PUMP STATION
99 ggraham
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
TM
225 AT
3P
65 KAIC
600 AF
TM
225 AT
3P
65 KAIC
225 AF
150 AT
3P
150 AF
TM
150 AT
3P
65 KAIC
600 AF
TM
65 KAIC
MCC-D
K K
TM
300 AT
3P
65 KAIC
600 AF
300 AT
3P
TM
65 KAIC
400 AF
K
TM
300 AT
3P
65 KAIC
600 AF
400 AT
3P
400 AF TM
65 KAIC
K
MCC-C
400 AT
3P
600 AF TM
65 KAIC 400 AT
3P
600 AF TM
65 KAIC
MCC70293
K K
TM
300 AT 65 KAIC
3P
600 AF
K
TM
300 AT 65 KAIC
3P
600 AF
K
MCC70292
TM
300 AT 65 KAIC
3P
600 AF
K
TM
300 AT 65 KAIC
3P
600 AF
K
MCC70291
1600 AT 65 KAIC
3P
1600 AF SS-LSIG
1600 AT 65 KAIC
3P
1600 AF SS-LSIG
SPD SPD
1600 AT
3P
1600 AF
52-B4
1600 AT
3P
1600 AF
52-A4SS SS
4000 AT
3P
5000 AF
52-MSS
2500 AT
3P
3200 AF
52-G1SS
100 KAIC
100 KAIC 100 KAIC
52-AT
100 KAIC
SWR12101, 5000AMPS, 480V, 3Ø, 4WIRE, 60HZ, 100KAIC
~
G
3 PHASE480V1875KVA/1500KW4 WIRE0.8 PF
GEN-1
3 PHASETFR-12500 KVA12KV480V5.75%
UTILITY
SWB70281, 1600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS SWB70282, 1600 AMPS, 480 V, 3 PHASE, 3 WIRE, 60 HZ, 65 KASC RMS
NC NC NC NO NC NO NC NO NO NO
NC
NC
NC
NC NC
NC
NC
NO
NO
PlotDate:12-JUL-202312:53:34PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E06
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HR
SMB
ELECTRICAL
SWBD70281 AND SWBD70282
ONE-LINE DIAGRAM
8660F10 8660F1003E06.dgn
GENERAL NOTES:
# KEY NOTES:
COMPLETE ONE-LINE DIAGRAM.WHERE NEEDED, OR REFER TO OWNER'S RECORD DRAWING FOR SHOWS SELECTIVE LOADS AND CONNECTIONS. FIELD VERIFY
3. ONE-LINE DIAGRAM FOR THIS EQUIPMENT IS PARTIAL AND ONLY BUILDING.
2. EXISTING SWITCHBOARD IS LOCATED INSIDE DAFT ELECTRICAL BUILDING.
1. EXISTING SWITCH GEAR IS LOCATED INSIDE POWER GENERATION 1 3
2 2
JGB
avates
SHALL FIELD VERIFY WHERE NEEDED.AND MAY NOT REFLECT EXACT FIELD CONDITION. CONTRACTOR
3. EXISTING EQUIPMENT INFORMATION ARE FROM RECORD DRAWINGS CONTRACTOR SHALL FIELD VERIFY WHERE NEEDED.DRAWINGS AND MAY NOT REFLECT ACTUAL FIELD INFORMATION. STATUS (OPEN/CLOSE), AND TRIP SETTINGS ARE FROM RECORD
2. EXISTING BREAKERS TYPE, RATINGS, FRAME SIZES, BREAKER 1. EXISTING SWITCHBOARD IS SQUARE D TYPE QED. 100
20" 20"
90"
20" 20" 20" 20" 20"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
#
GENERAL NOTES:
KEY NOTES:
2. REMOVE AND DISPOSE OF EXISTING MCC BUCKET COVER.
INSIDE MCC BUCKET.
1. REMOVE AND DISPOSE OF EXISTING ELECTRICAL EQUIPMENT
1 A -
B -C -D -
E -F -
G -
H -I -J -
K -
L -
2 3 4 5 6
1 2
2 1
1 2 2 2
1A- SPACE 2A- SPACE 3A- SPACE 4A- SPACE 5A- FILTER
SURFACE WASHPUMP
6A- METERING
1C- AWT
PUMP NO. 1
2C- AWT
PUMP NO. 3
3C- AIR WASH
BLOWER NO. 2
4C- FILTER
BACKWASHPUMP NO. 2
5C- WASHWATER
SLUDGE PUMP
6C- MAIN BREAKER 1
1F- AWT
PUMP NO. 2
2F- AIR WASH
BLOWER NO. 1
3F- FILTER
BACKWASHPUMP NO. 1
4G- AIR
COMPRESSOR
5E- DP1
DISTRIBUTIONPANEL 1
6H- MAIN BREAKER 2
1I- HWCP-5
HOT WATERPUMP
2I- SPACE 3JL3JR-UH-9 UNIT HEATER
ROLL UP DOOR
4I- WASHWATER
RETURN PUMP
1K- RAPID MIX
PUMP
2K- SPACE 3L- SPACE 4KL4KR-XFMR-A PNL-A LIGHTING PANELBOARD DP1 DISTRIBUTIONPANEL 1
1 1. EXISTING MCC IS WESTINGHOUSE, SERIES 2100.
3/4" = 1'-0"
8660F1003E9621
3/4" = 1'-0"
8660F1003E9621
1 PlotDate:12-JUL-202312:55:02PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E09
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
SMB
ELECTRICAL
8660F10 8660F1003E09.dgn
MCC-C DEMO ELEVATION
JGB
101
bshepard
20" 20"
90"
20" 20" 20" 20" 20"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
1 A -
B -C -D -
E -F -
G -
H -I -J -
K -
L -
2 3 4 5 6
#
GENERAL NOTES:
KEY NOTES:
1 1
2 1 1 1 1
1 3
NOT COMPLETELY FILL SPACE OF REMOVED UNIT.
3. PROVIDE COVERS FOR MCC AS NEEDED WHERE NEW UNITS DO
ACTUAL EQUIPMENT DIMENSIONS IN THE FIELD.
2. EXISTING MCC OVERALL DIMENSIONS MAY NOT REFLECT THE 1. EXISTING MCC IS WESTINGHOUSE, SERIES 2100. 3/4" = 1'-0"
8660F1003E0621
3/4" = 1'-0"
8660F1003E0621
ELEVATION TABLE.
3. RELABEL EXISTING MCC BUCKET ACCORDING TO MCC 2. PROVIDE NEW COVER.
CONTROL SCHEMATICS, AND SPECIFICATIONS.NECESSARY EQUIPMENT ACCORDING TO ONE-LINE DIAGRAMS,
1. PROVIDE NEW BREAKER, MOTOR STARTERS AND ALL THE
1 1
1A- FAN-85109
AIR WASHBLOWERFAN NO. 1
2A- FAN-85110
AIR WASHBLOWERFAN NO. 2
3A- FAN-85111
AIR WASHBLOWERFAN NO. 3
4A- DP2
DISTRIBUTIONPANEL 2
5A- FILTER
SURFACE WASHPUMP
6A- METERING
1C- AWT
PUMP NO. 1
2C- AWT
PUMP NO. 3
3C- BLO-85107
AIR WASHBLOWER NO. 2
4C- FILTER
BACKWASHPUMP NO. 2
5C- PMP-87134
BACKWASHCHLORINESAMPLE PUMP
6C- MAIN BREAKER
A
1F- AWT
PUMP NO. 2
2F- BLO-85106
AIR WASHBLOWER NO. 1
3F- FILTER
BACKWASHPUMP NO. 1
4G- AIR
COMPRESSOR
5E- DP1
DISTRIBUTIONPANEL 1
6H- MAIN BREAKER
B
1I- HWCP-5
HOT WATERPUMP
2I- BLO-85108
AIR WASHBLOWER NO. 3
3JL3JR-UH-9 UNIT HEATER ________________ ROLL UP DOOR 4I- SPARE NEMA 2 1K- PMP-85104
RAPID MIXPUMP
2L- SPACE 3L- SPACE 4KL4KR - XFMR-A PNL-A LIGHTING PANELBOARD ________________ DP1 DISTRIBUTIONPANEL 1BREAKER
PlotDate:12-JUL-202312:50:24PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E10
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
SMB
ELECTRICAL
8660F10 8660F1003E10.dgn
ELEVATION
MCC-C MODIFIED
JGB
102
bshepard
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
3P
MCP
FVNR
SLUDGE
65 KAIC
SIZE 1
15 AC
SECONDARY
PUMP NO. 1
5 3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 1
3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 2
3P
MCP
FVNR
3/4
65 KAIC
SIZE 1
3 AC
HOT WATER
PUMP
HWCP-5
3P
MCP
FVNR
1.5 65 KAIC
SIZE 1
7 AC
RAPID MIX
PUMP
5 3P
MCP
7.5 3-#12(Ø)&1-#12(G)
15 AC 65 KAIC
RAPID MIX
PUMP
PMP-85104
3P
MCP
FVNR
40 65 KAIC
SIZE 3
100 AC
AWT
PUMP NO. 3
3P
MCP
50 RVSS
100 AC 65 KAIC
BLOWER NO. 1
3P
MCP
50 RVSS
100 AC 65 KAIC
BLOWER NO. 2
3P
MCP
60 FILTER
65 KAIC
SIZE 4
100 AC
PUMP NO. 1
BACKWASH
3P
TM
15 AT 65 KAIC
UNIT HEATER
UH-9
KW
3 3P
TM
15 AT 65 KAIC
ROLL UP DOOR
HP
2 3P
MCP
60 FILTER
65 KAIC
SIZE 4
100 AC
PUMP NO. 2
BACKWASH
3P
MCP
FVNR
65 KAIC
SIZE 2
15 AC
AIR
COMPRESSOR
5 3P
MCP
FVNR
65 KAIC
SIZE 2
30 AC
3P
TM
30 KVA
50 AT 65 KAIC
XFMR-A
208/120 V480 V
LIGHTING
PANELBOARD
PNL-A
3 PH
TM
3P
60 AT 65 KAIC
DP1
DISTRIBUTION
PANEL 1
3P
MCP
FVNR
15 FILTER
65 KAIC
SIZE 2
30 AC
PUMP
SURFACE WASH
3P
MCP
FVNR
65 KAIC
SIZE 2
30 AC
3P
TM
300 AT 65 KAIC
400 AF
MCC-C, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS
CONTINUEDATUPPERRIGHT
CONTINUEDATLOWERLEFT
# KEY NOTES:
1 1 1
REMAIN IN PLACE.UNDERGROUND AND CONCRETE EMBEDDED CONDUITS SHALL WHICH ARE MARKED ON THIS DRAWING FOR DEMOLITION.
1. DEMOLISH EXPOSED CONDUITS, AND ALL CABLES FOR CIRCUITS 3P
TM
400 AT 65 KAIC
400 AF
SPD
MAIN BREAKER 1 MAIN BREAKER 2
3P K K
TM65 KAIC
DP2
DISTRIBUTION
PANEL 2
CONTINUEDONNEXTSHEET
06N05
6 06N06
6 06N06
6 06N06
SPARE SPARE
AIR WASH AIR WASH
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 1
AIR WASH
50 AC
BLO-85106
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 3
AIR WASH
50 AC
BLO-85108
3P
MCP
20 RVSS
65 KAIC
BLOWER NO. 2
AIR WASH
50 AC
BLO-85107
100 AT
3-#2(Ø)&1-#8(G)
PlotDate:12-JUL-202312:48:53PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E11
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
SMB
ELECTRICAL
8660F10 8660F1003E11.dgn
MCC-C MODIFIED
ONE-LINE DIAGRAM 1
JGB
103
bshepard
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
CONTINUEDONPREVIOUSSHEET
3P
MCP
1/2
3-#12(Ø)&1-#12(G)
3 AC 65 KAIC
FAN-85109
FVNRSIZE 1
FAN NO. 1
3P
MCP
1/2
3-#12(Ø)&1-#12(G)
3 AC 65 KAIC
FAN-85110
FVNRSIZE 1
FAN NO. 2
3P
MCP
1/2
3-#12(Ø)&1-#12(G)
3 AC 65 KAIC
FAN-85111
FVNRSIZE 1
FAN NO. 3
MCC-C, 600 AMPS, 480 V, 3 Ø, 3 WIRE, 60HZ, 65KASC RMS
AIR WASH BLOWER AIR WASH BLOWER AIR WASH BLOWER
3P
MCP
1/2
3-#10(Ø)&1-#12(G)
3 AC 65 KAIC
PMP-87134
FVNRSIZE 1
BACKWASH
CHLORINE SAMPLE PUMP
PlotDate:12-JUL-202312:54:09PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E12
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
SMB
ELECTRICAL
8660F10 8660F1003E12.dgn
MCC-C MODIFIED
ONE-LINE DIAGRAM 2
JGB
104
ggraham
20"
90"
20"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
5 A -
B -C -D -
E -F -
G -
H -I -J -
K -
L -
#
GENERAL NOTES:
KEY NOTES:
1. EXISTING MCC IS SQUARE D MODEL 6.2. PROVIDE NEW COVER.
SCHEMATICS, AND SPECIFICATIONS.EQUIPMENT ACCORDING TO ONE-LINE DIAGRAMS, CONTROL
1. PROVIDE NEW BREAKER, DRIVES AND ALL THE NECESSARY
3/4" = 1'-0"
8660F1003E0622
3/4" = 1'-0"
8660F1003E0622
5A- SPACE5C- GDR75112
SLUDGEGRINDERDIGESTER 1
5D- P97101
DRAINAGEPUMP 1
5E- PMP-89100
CAROUSELPUMP NO. 1
5F- FV-60100
DCLSTRUCTUREVALVE 1
5G- FV-60102
DCLSTRUCTUREVALVE 2
5H- SPACE5J- SPACE
PlotDate:12-JUL-202312:51:51PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E18
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
8660F10 8660F1003E18.dgn
MCC70291 PARTIAL ELEVATION
2 1
JGB
2 ggraham
105
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
CONTINUEDATLOWERLEFT
CONTINUEDATUPPERRIGHT
3P
TM
10 20 AT 65 KAIC
DAFT AIR
COMPRESSOR 1
LCP70201
HP
3P
MCP
FVNR
1/2
SAMPLE
PUMP 1
65 KAIC
SIZE 1
3 AC
CHLORINE
RESIDUAL
P60211
3P
MCP
FVNR
40 PUMP 1
65 KAIC
SIZE 3
100 AC
PRESSURIZATION
P70221
3P
MCP
FVNR
65 KAIC
SIZE 1
15 AC
DIGESTER 1
PUMP
CIRCULATION
P75111
5 3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC
RECLAIMED
FEED PUMP 1
WATER FILTER
P80111
3P
TM
UNIT 1
POLYMER
20 AT 65 KAIC
BLENDING
PNL70251
AMP
1 3P
TM
GRINDER
SLUDGE
15 AT 65 KAIC
DIGESTER 1
GDR75112
HP
3 SPD
3 MCC70291, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS SSM
3 SSM
SWB70281
MLO
SWB70282
MLO
3P
TM
FVNR
1.5 SLUDGE
DAFT 1
15 AT 65 KAIC
SIZE 1
COL70121B
COLLECTOR
3P
MCP
7.5 15 AT 65 KAIC
MX75101
DIGESTER 1
MIXER
7.5 3P
TM
VFD
20 AT 65 KAIC
P70131
THICKENED
SLUDGE
PUMP 1
VFD70131
3P
TM
35 AT 65 KAIC
HP
20 P97101
DRAINAGE
PUMP 1
3 PHASE15 KVA
TM
3P
480V208/120V
45 AT 65 KAIC
XFMR70271 PNL70271
SPARE
SIZE 1FVNR
MCP
3P
15 AT 65 KAIC
SPARE
TM
3P
20 AT 65 KAIC
LL
40 3P
TM
80 AT 65 KAIC
CAROUSEL
VFD-89100
PMP-89100
PUMP NO. 1
VFD-6
VFD
DV/DT
3P
TM
VALVE 2
3-#10(Ø)&1-#10(G)
3-#10(Ø)&1-#10(G)
15 AT 65 KAIC
5 HP
FV-60102
DCL STRUCTURE
3P
TM
VALVE 1
3-#10(Ø)&1-#10(G)
3-#10(Ø)&1-#10(G)
15 AT 65 KAIC
5 HP
FV-60100
DCL STRUCTURE
VFD-6
3/4
3P
15 AT 65 KAIC
TM
COL70121A
DAFT 1 FLOAT
COLLECTOR
3-#6(Ø)&1-#8(G)
[3-#4(Ø)&INTEGRAL(G)]:VFD
1. EXISTING MCC IS SQUARE D MODEL 6.
#
H040S2BLG. CORPORATION, MODEL# BF48A, AND CATALOG#:AND 16262. EXISTING MOTOR IS MADE BY NIDEC MOTOR MANUFACTURER, AND SPECIFICATION SECTIONS 16222SHALL BE COORDINATED WITH THE EXISTING PUMP WITH NEW VFD DUTY RATED MOTOR. MOTOR SELECTION
1. REPLACE EXISTING MOTOR FOR THE EXISTING PUMP
GENERAL NOTES:
KEY NOTES:
1 PlotDate:12-JUL-202312:49:19PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E19
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
MCC70291 ONE-LINE DIAGRAM
8660F10 8660F1003E19.dgn
3 06N03
JGB
avates
106
20"
90"
20"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
6 A -
B -C -D -
E -F -
G -
H -I -J -
K -
L -
#
GENERAL NOTES:
KEY NOTES:
1. EXISTING MCC IS SQUARE D MODEL 6.
1 SPECIFICATIONS.ACCORDING TO ONE-LINE DIAGRAMS, CONTROL SCHEMATICS, AND
1. PROVIDE NEW BREAKER AND ALL THE NECESSARY EQUIPMENT
6A- POLYMER
BLENDING UNIT 2PNL70272
6B- 20A SPARE
BREAKER
6C- LCP70202
DAFT AIR COMP 2
6D- SPARE
STARTER - SIZE 1
6F- GDR75122
DIGESTER 2SLUDGE GRINDER
6G- PMP-89101
CAROUSEL PUMP NO. 2
6H- SPACE6J- SWB70282
3/4" = 1'-0"
8660F1003E0623
3/4" = 1'-0"
8660F1003E0623
PlotDate:12-JUL-202312:52:28PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E20
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
8660F10 8660F1003E20.dgn
MCC70292 PARTIAL ELEVATION
JGB
107
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
CONTINUEDATLOWERLEFT
CONTINUEDATUPPERRIGHT
MLO
MLO
3P
MCP
FVNR
1.5 SLUDGE
DAFT 2
65 KAIC
SIZE 1
7 AC
COLLECTOR
COL70122B
3P
TM
10 20 AT 65 KAIC
DAFT AIR
COMPRESSOR 2
LCP70202
HP
3P
MCP
FVNR
1/2
SODIUM
65 KAIC
SIZE 1
3 AC
UNIT
INDUCTION
HYPOCHLORITE
MME60202
3P
MCP
FVNR
1/2
SODIUM
65 KAIC
SIZE 1
3 AC
UNIT
INDUCTION
BISULFITE
MME60401
3P
TM
UNIT 2
POLYMER
15 AT 65 KAIC
BLENDING
MME70252
HP
1 3P
MCP
FVNR
1/2
SAMPLE
PUMP 2
65 KAIC
SIZE 1
3 AC
CHLORINE
RESIDUAL
P60213
3P
MCP
FVNR
40 PUMP 2
65 KAIC
SIZE 3
100 AC
PRESSURIZATION
P70222
3P
MCP
FVNR
7.5 65 KAIC
SIZE 1
15 AC
DIGESTER 2
PUMP
CIRCULATION
P75121
3P
TM
SLUDGE
GRINDER
15 AT 65 KAIC
DIGESTER 2
PNL75122
HP
3 SPD
SSM
3 SWB70281
SSM
3 SWB70282
MCC70292, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC
RECLAIMED
FEED PUMP 2
WATER FILTER
P80112
VFD-6
LL
40 3P
TM65 KAIC
CAROUSEL
VFD-89101
80 AT
PMP-89101
3P
TM
7.5 20 AT 65 KAIC
MX75102
DIGESTER 2
MIXER
7.5 3P
TM
20 AT 65 KAIC
THICKENED
SLUDGE
PUMP 2
P70132
DV/DT
3 PHASE15 KVA
TM
3P
480 V120/2080 V
45 AT 65 KAIC
XFMR70272 PNL-70272
VFD
VFD
SPARE
TM
3P
20 AT 65 KAIC
SPARE
SIZE 1FVNR
MCP
3P
15 AC 65 KAIC
[3-#4(Ø)&INTEGRAL(G)]:VFD
3-#6(Ø)&1-#8(G)
HP
3P
TM
COL70122A
DAFT 2 FLOAT
COLLECTOR
VFD
1. EXISTING MCC IS SQUARE D MODEL 6.
#
H040S2BLG.CORPORATION, MODEL# BF48A, AND CATALOG#:AND 16262. EXISTING MOTOR IS MADE BY NIDEC MOTOR MANUFACTURER, AND SPECIFICATION SECTIONS 16222SHALL BE COORDINATED WITH THE EXISTING PUMP WITH NEW VFD DUTY RATED MOTOR. MOTOR SELECTION
1. REPLACE EXISTING MOTOR FOR THE EXISTING PUMP
GENERAL NOTES:
KEY NOTES:
1 3
06N03
PUMP NO. 2
PlotDate:12-JUL-202312:49:28PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E21
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
MCC70292 ONE-LINE DIAGRAM
8660F10 8660F1003E21.dgn
JGB
108
ggraham
20"
90"
20"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
7 A -
B -C -D -
E -F -
G -
H -I -J -
K -
L -
#
GENERAL NOTES:
KEY NOTES:
1. EXISTING MCC IS SQUARE D MODEL 6.2. PROVIDE NEW COVER.
ACCORDING TO SINGLE LINE DIAGRAMS AND SPECIFICATIONS.
1. PROVIDE NEW BREAKER AND ALL THE NECESSARY EQUIPMENT
1 2
7A- SPACE7B- 30A SPARE
BREAKER
7C- UH70244
DAFT EQUIP. ROOMUNIT HEATER
7D- EDR-99101
EDR-99102FLOW CONTROLVALVES NO. 1 AND NO. 2
7E- PMP-89102
CAROUSEL PUMP NO. 3
7F- PMP-91100
PAU PUMP NO. 1
7G- SPACE7I- METERING7J- 600A MLO
3/4" = 1'-0"
8660F1003E0624
3/4" = 1'-0"
8660F1003E0624
PlotDate:12-JUL-202312:50:43PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E22
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
8660F10 8660F1003E22.dgn
MCC70293 PARTIAL ELEVATION
JGB
109
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
CONTINUEDATLOWERLEFT
CONTINUEDATUPPERRIGHT
MLO
MLO
SSM
3 SWB70281
SSM
3 SWB70282
3P
TM
10 20 AT 65 KAIC
DAFT
UNIT
HANDLING
BUILDING AIR
AHU70246
KW
3P
TM
1.5 DAFT 3
SLUDGE
FUTURE
15 AT 65 KAIC
COLLECTOR
HP
3P
TM
10 20 AT 65 KAIC
DAFT AIR
COMPRESSOR 3
LCP70203
HP
3P
MCP
FVNR
1/2
UNIT 1
SODIUM
65 KAIC
SIZE 1
3 AC
INDUCTION
HYPOCHLORITE
MME60201
3P
MCP
FVNR
1/2
SAMPLE
PUMP 4
65 KAIC
SIZE 1
3 AC
CHLORINE
RESIDUAL
P60411
3P
MCP
FVNR
20 65 KAIC
SIZE 2
50 AC
RECLAIMED
FEED PUMP 3
WATER FILTER
P80113
3P
TM
POLYMER
UNIT 3
FUTURE
15 AT 65 KAIC
BLENDING
PLC70299
HP
1 SPD
TM
3P
65 KAIC
2 STORM DRAIN
PUMP 1
MCC70293, 600 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3P
TM
3/4
FUTURE
15 AT 65 KAIC
DAFT 3 FLOAT
COLLECTOR
VCP-SD
2 STORM DRAIN
PUMP 2
3P
MCP
FVNR
20 BLOWER
50 AC 65 KAIC
SIZE 2
CHLORINATION
AERATION
B60221
3P
MCP
FVNR
1/2
SAMPLE
3 AC 65 KAIC
SIZE 1
RESIDUAL
P60215
CHLORINE
PUMP 3
PUMP
7.5 3P
TM
15 AT 65 KAIC
THICKENED
SLUDGE
VFD
P70133
3P
MCP
FVNR
40 65 KAIC
SIZE 3
P70223
100 AC
PRESSURIZATION
PUMP 3
3P
TM
20 PUMP 2
35 AT 65 KAIC
HP
P97102
3P
TM
15 AT 65 KAIC
KVA
5 PNL80114
RECLAIMED
WATER FILTER
CONTROL
PANEL
VFD-6
LL
10 3P
TM
25 AT 65 KAIC
3-#10(Ø)&1-#10(G)
DV/DT
PMP-91100
VFD-91100
PAU PUMP NO. 1
VFD-6
LL
40 3P
TM65 KAIC
DV/DT
PMP-89102
VFD-89102
CAROUSEL
3P
TM
20 AT 65 KAIC
RIVER
DISCHARGE
CONTROL VALVE
3 PHASE15 KVA
TM
3P
480 V120/208 V
45 AT 65 KAIC
XFMR70273 PNL70273
VFD
DRAINAGE
80 AT
TM
3P
HP HP
VALVE NO. 1
CONTROL
FLOW
EDR-99101
VALVE NO. 2
CONTROL
FLOW
EDR-99102
15 AT 65 KAIC
[3-#8(Ø)&INTEGRAL(G)]:VFD
[3-#4(Ø)&INTEGRAL(G)]:VFD
3-#6(Ø)&1-#8(G)
3-#10(Ø)&1-#10(G)
1. EXISTING MCC IS SQUARE D MODEL 6.
GENERAL NOTES:
4 06N04
3 06N04
PUMP NO. 3
PlotDate:12-JUL-202312:49:37PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 03E23
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
MCC70293 ONE-LINE DIAGRAM
8660F10 8660F1003E23.dgn
bshepard
JGB
110
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PANEL PNL-RWPS-L 3/6/2023
LIRWPS
LOCATION: RECYCLED WATER PUMP STATION ELECTRICAL BUILDING NEMA: 1 PH A WEIGHTED VA 6195VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 4035PHASE & WIRE: 3 PH 4W MTG. SURFACE PH C WEIGHTED VA 7613INTERRUPT: 10 KAIC BUS RATING: 100OPTIONS: SPD MAIN: CB EQUIP SIZING VA 22838 MAIN RATING: 125 AF 100 AT PANEL AMPS 63.4
I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C RECYCLED WATER ELECTRICAL BUILDING LIGHTING 280 20A-1P 1 A 2 20A-1P 720 RECYCLED WATER ELECTRICAL BUILDING RECEPTACLES I I RECYCLED WATER ELECTRICAL BUILDING RECEPTACLES 360 20A-1P 3 B 4 20A-1P 340 RECYCLED WATER PUMP STATION LIGHTING CI RECYCLED WATER PUMP STATION RECEPTACLES 900 20A-1P 5 C 6 35A-2P 2600 CU-99422 - OUTDOOR CONDENSER UNIT NO. 2 C C PCM-99400 POWER FEED NO. 1 1500 20A-1P 7 A 8 2600 FCU-99422 C S PCM-99400 POWER FEED NO. 2 1500 20A-1P 9 B 10 35A-2P 2600 CU-99421 - OUTDOOR CONDENSER UNIT NO. 1 C C RECYCLED WATER STORAGE LIGHTING 170 20A-1P 11 C 12 2600 FCU-99421 C SPARE 20A-1P 13 A 14 20A-1P SPARESPARE 20A-1P 15 B 16 20A-1P SPARESPARE 20A-1P 17 C 18 20A-1P SPARESPARE 20A-1P 19 A 20 20A-1P SPARESPARE 20A-1P 21 B 22 20A-1P SPARESPARE 20A-1P 23 C 24 20A-1P SPARESPARE 20A-1P 25 A 26 20A-1P SPARESPARE 20A-1P 27 B 28 20A-1P SPARESPARE 20A-1P 29 C 30 20A-1P SPARE PANEL DP2 3/30/2023
LOCATION: ADVANCE WATER TREATMENT (AWT) NEMA: 1 PH A WEIGHTED VA 13334VOLTS: 480 FEED: TOP PH B WEIGHTED VA 13334PHASE & WIRE: 3 PH 3W MTG. SURFACE PH C WEIGHTED VA 13334INTERRUPT: 65 KAIC BUS RATING: 100OPTIONS: SPD MAIN: CB EQUIP SIZING VA 40002 MAIN RATING: 100 AF 100 AT PANEL AMPS 48.1
I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S I 1469 1 A 2 1719 II FCV-85211 & FV-85212 & FV-85214 - FILTER 1 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 3 B 4 15A-3P 1719 FV-85217 & FCV-85218 & FV-85219 - FILTER 1 BACKWASH & EFFLUENT & AIR SCOUR VALVES II 1469 5 C 6 1719 II 1469 7 A 8 1719 II FCV-85221 & FV-85222 & FV-85224 - FILTER 2 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 9 B 10 15A-3P 1719 FV-85227 & FCV-85228 & FV-85229 - FILTER 2 BACKWASH & EFFLUENT & AIR SCOUR VALVES II 1469 11 C 12 1719 II 1469 13 A 14 1719 II FCV-85231 & FV-85232 & FV-85234 - FILTER 3 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 15 B 16 15A-3P 1719 FV-85237 & FCV-85238 & FV-85239 - FILTER 3 BACKWASH & EFFLUENT & AIR SCOUR VALVES II 1469 17 C 18 1719 II 1469 19 A 20 1719 II FCV-85241 & FV-85242 & FV-85244 - FILTER 4 INFLUENT & AIR VALVES AND WASTE GATE 1469 15A-3P 21 B 22 15A-3P 1719 FV-85247 & FCV-85248 & FV-85249 - FILTER 4 BACKWASH & EFFLUENT & AIR SCOUR VALVES II 1469 23 C 24 1719 II 582 25 A 26I FV-87130 - HIGH RATE BACKWASH VALVE 582 15A-3P 27 B 28 15A-3P SPAREI 582 29 C 30 31 A 32
SPARE 15A-3P 33 B 34 15A-3P SPARE
35 C 36
37 A 38
SPARE 15A-3P 39 B 40 15A-3P SPARE
41 C 42
PlotDate:12-JUL-202312:47:53PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 04E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1004E01.dgn
JGB
PANELBOARD SCHEDULES 1
avates
111
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
# KEY NOTES:
3 2
4 1
1 1
4. EXISTING PANELBOARD IS SQUARE D TYPE NQOD.3. EXISTING PANELBOARD IS SQUARE D TYPE NQOD.
ACCORDINGLY.CHANGES TO PANEL CIRCUIT SCHEDULE IN THE FIELD
2. PROVIDE NEW CIRCUIT FOR THE NEW LOADS. REFLECT
PROVIDED PANEL BOARD SCHEDULE.RELOCATE CIRCUIT BREAKERS AS NEEDED TO MATCH
1. RENAME THIS CIRCUIT IN THE PANEL CIRCUIT SCHEDULE.
PA PNL-A 3/9/2023
LOCATION: AWT BUILDING NEMA: 1 PH A WEIGHTED VA 8863VOLTS: 208/120 FEED: TOP PH B WEIGHTED VA 9933PHASE & WIRE: 3 PH 4W MTG. SURFACE PH C WEIGHTED VA 9496INTERRUPT: 10 KAIC BUS RATING: 100OPTIONS: SPD MAIN: CB EQUIP SIZING VA 29798 MAIN RATING: 100 AF 100 AT PANEL AMPS 82.7
I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C LTS-CONTROL/BLOWER ROOM 500 20A-1P 1 A 2 20A-1P 700 RCPT-CONTROL/BLOWER ROOM IC LTS-CHEMICAL FEED ROOM 1000 20A-1P 3 B 4 20A-1P 800 RCPT-CHEMICAL FEED ROOM IC LTS-AWT CLARIFIER/FILTER 1000 20A-1P 5 C 6 20A-1P 800 RCPT - AWT CLARIFIER/FILTER IC LTS-EXTERIOR 300 20A-1P 7 A 8 20A-1P 500 RCPT - AWT CLARIFIER/FILTER IC EF-5 CHEMICAL FEED 670 20A-1P 9 B 10 20A-1P 450 UH-6, UH-7, UH-8 CC EF-6 CHEMICAL FEED 670 20A-1P 11 C 12 20A-1P SPAREC EF-7 CONTROL ROOM 670 20A-1P 13 A 14 15A-1P 1000 EWH-1 CC EF-8 BLOWER ROOM 670 20A-1P 15 B 16 20A-1P 1100 COAGULANT AID POLYMER FEEDER #1 CC AWT BUILDING CONTROL PANEL 1000 20A-1P 17 C 18 20A-1P 1100 COAGULANT AID POLYMER FEEDER #2 SC CAUSTIC LEAK PANEL 500 20A-1P 19 A 20 20A-1P 830 FILTER AID POLYMER FEEDER CC COAGULANT LEAK PANEL 500 20A-1P 21 B 22 20A-1P 1186 VCP-85183 - COAGULANT FEED CONTROL PANEL NO. 3 CC AIT-108/ AIT-109 200 20A-1P 23 C 24 20A-1P 1186 VCP-85182 - COAGULANT FEED CONTROL PANEL NO. 2 SC AIT-110/ AIT-111 200 20A-1P 25 A 26 20A-1P 1186 VCP-85181 - COAGULANT FEED CONTROL PANEL NO. 1 S SPARE 20A-1P 27 B 28 20A-1P 1100 CAUSTIC FEED PUMP #2 S C VCP-3 - AWT CLARIFIER/FILTER CONTROL PANEL 1000 20A-1P 29 C 30 20A-1P 1100 CAUSTIC FEED PUMP #1 C I LTG & RCPT AWT & BACKWASH PS 500 20A-1P 31 A 32 20A-1P 300 HEAT TAPE C C SAMPLE PUMP NO. 1 1130 20A-1P 33 B 34 20A-1P 300 HEAT TAPE CC SAMPLE PUMP NO. 2 1587 20A-1P 35 C 36 20A-1P 300 HEAT TAPE CC SAMPLE PUMP NO. 3 1130 20A-1P 37 A 38 20A-1P 300 HEAT TAPE C SPARE 20A-1P 39 B 40 20A-1P 300 HEAT TAPE CSPARE 20A-1P 41 C 42 15A-1P 100 BINKLEY ALARM C PANEL PNL70271 4/4/2023
LOCATION: DAFT BUILDING - MCC70271 NEMA: 1 PH A WEIGHTED VA 4568VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 4173PHASE & WIRE: 3 PH 4W MTG. MCC PH C WEIGHTED VA 3721INTERRUPT: 10 KAIC BUS RATING: 100OPTIONS: SPD MAIN: CB EQUIP SIZING VA 13703 MAIN RATING: 100 AF 60 AT PANEL AMPS 38.0
I/C/S DESCRIPTION LOAD (VA) BKR CIR CIR BKR LOAD (VA) DESCRIPTION I/C/S C P60321 (PNL60321) 600 20A-1P 1 A 2 20A-1P 100 FIT7521 CC P60341 (PNL60341) 100 20A-1P 3 B 4 20A-1P 100 FIT7025 CC LTG-DIGESTERS 173 20A-1P 5 C 6 20A-1P 100 FIT7041 CC RECPT-DIGESTERS 180 20A-1P 7 A 8 20A-1P 248 DAFT DECK LIGHTNING CC FIT6031 100 20A-1P 9 B 10 20A-1P 850 DAFT TANK LIGHTNING CC LIT6011 100 20A-1P 11 C 12 20A-1P 360 DAFT TANK RECEPTACLE IC PNL60301 600 20A-1P 13 A 14 20A-1P 650 DAFT BLDG INTERIOR LTG CC PNL60331 600 20A-1P 15 B 16 20A-1P 650 DAFT BLDG INTERIOR LTG CC FIT8001 100 20A-1P 17 C 18 20A-1P 720 DAFT BLDG INTERIOR RECEP IC FIT8002 100 20A-1P 19 A 20 20A-1P 720 DAFT BLDG INTERIOR RECEP IC MME60212 (AIT6004) 100 20A-1P 21 B 22 20A-1P 500 RESTROOM MINI WATER HTR CC NJB-60001 - ETHERNET SWITCH 100 15A-1P 23 C 24 20A-1P 100 LCP70272 CC FIT-99105 - METERING VAULT FLOW METER 100 20A-1P 25 A 26 20A-1P 500 PNL70241 C I CAROUSEL AND PAU RECEPTACLES 360 20A-1P 27 B 28 20A-1P 50 CV70261 C C CAROUSEL AND PAU LIGHTING 360 20A-1P 29 C 30 20A-1P 1080 PLC70299 C PlotDate:12-JUL-202312:51:39PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 04E02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1004E02.dgn
JGB
PANELBOARD SCHEDULES 2
112
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
DISCONNECT SCHEDULE 11/17/2022
TAG VOLTAGE POLES AMPS NEMA TYPE TYPE HORSEPOWER FUSE SIZE BREAKER AF/AT ACCESSORIES B 600 VAC 3P 30A 4X-SS NON-FUSEDE 600 VAC 3P 60A 4X-SS NON-FUSED 4 S 600 VAC 3P 200A 4X-SS NON-FUSED 4
T 600 VAC 2P 60A 4X-SS NON-FUSED
ACCESSORIES 1="B" TYPE ELECTRICAL INTERLOCK FOR POSITION INDICATION 2=INSULATED GROUNDABLE NEUTRAL KIT3=DRAIN AND BREATHER KIT WHEN OUTDOORS4=EARLY BREAK AUXILIARY CONTACT LUMINAIRE SCHEDULE 3/8/2023
ITEM DESCRIPTION MOUNTING LAMP LUMINAIRE SPECIFICATIONS
METHOD QUANTITY TYPE MANUFACTURER CATALOG VOLTS VA
A
AUTOBAHN SERIES ATBM POLE LIGHT, ROADWAY TYPE III DISTRIBUTIONFOUR-BOLT MAST ARM MOUNT FOR 1.25 TO 2 INCH OD POLEw/ROUND TAPERED POLE WITH MOUNTING ARMPROVIDE MOUNTING FOR TWO HEADS/ARMS ON A SINGLE POLE WHERE SHOWNCOLOR TO MATCH EXISTING LIGHT POLES AND ANODIZED ALUMINUM, 12'-0" HIGH, 4" DIA7 PIN INTEGRAL PHOTOCELL SENSOR AND CONTROL WITH DIMMABLE DRIVEPROVIDE EMBEDDED GFCI RECEPTACLE WITH WEATHER PROOFING COVER WHERE SHOWN POLE
MOUNT
N/A
LED
4000 CCT
10,675 LUMENS
AMERICAN
ELECTRIC
LIGHTING
ATBM P10 MVOLT R3 4B UMR-XX P7 120 81
B
SEALED, AND GASKETED LED LUMINAIRE, CLEAR POLYCARBONATE LENS80 CRI, SUITABLE FOR WET LOCATIONS, w/ HIGH EFFICIENCY LEDsFOR AMBIENT TEMPERATURES -29 TO 40 DEG C, L80 AT 75,000 HOURSCALIFORNIA ENERGY CODE COMPLIANT BUILT-IN EMERGENCY BACKUP WHERE SHOWN
CEILING MOUNT
OR SUSPENDED
AS NEEDED
N/A
LED
4000K CCT
6,643 LUMENS
HOLOPHANE EVT4 6000LM PCL WD MVOLT 40K 80 120 71
C
DELEON TL SINGLE FACE EXIT SIGN, UL WET LOCATION LISTED, SELF DIAGNOSTICSAMBIENT TEMPERATURES -40 TO 45 DEG C DUAL VOLTAGE 120/277 w/GREEN EXIT LETTERSSELF-CONTAINED, SEALED MAINTENANCE FREE NICKEL CADMIUM BATTERIES WALL
OR CEILING
MOUNT
N/A LED HOLOPHANE LNTLL NC W SG S 120 4.8
D
BUILDING-MOUNTED LUMINAIRE WITH ALUMINUM HOUSING SEALED AGAINSTMOISTURE AND ENVIRONMENTAL CONTAMINANTS70 CRI, TYPE IV LIGHT DISTRIBUTION, HIGH EFFICIENCY LEDsw/ MOTION/AMBIENT LIGHT SENSOR, DARK BRONZE WITH BATTERY PACK
WALL MOUNT N/A
LED
4000K CCT
2,000 LUMENS
LITHONIA
MRW LED P1 40K SR4 MVOLT PIR DDBXD
E20WC
120 28.8
ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE 4/3/2023
TAG NO
MINIMUM INTERIOR
DIMENSIONS (INCHES) CONSTRUCTION TYPICAL
DETAIL
SURFACE
LOADING
COMMENTS
WIDTH LENGTH DEPTH
COUED-4 60 60 48 60" ROUND PRECAST ROADWAY COUED "504" CUSTOM CONSTRUCTION FOR MV VAULT HH-1 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-2 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-3 60 60 60 PRECAST CONCRETE EM056 ROADWAY
HH-4 52 52 62 PRECAST CONCRETE EM056 SIDEWALK
HH-10 52 52 62 PRECAST CONCRETE EM056 ROADWAY
HH-11 44 44 54 PRECAST CONCRETE EM056 ROADWAY
MH-12 60 60 84 PRECAST CONCRETE EM062 ROADWAY
HH-13 44 44 54 PRECAST CONCRETE EM056 ROADWAY
HH-20 48 48 54 PRECAST CONCRETE EM056 ROADWAY
HH-21 48 48 54 PRECAST CONCRETE EM056 ROADWAY
NOTES:1. SEE SPECIFICATION 02581 FOR PRECAST ELECTRICAL HANDHOLES AND MANHOLES.2. ALTERNATES: PROVIDE PER TYPICAL DETAIL EM062 IF INDICATED UNDER "COMMENTS".
PlotDate:12-JUL-202312:50:28PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 05E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1005E01.dgn
JGB
# KEY NOTES:
EFFICIENCY STANDARD SECTION 130.0(c).
1. LUMINAIRE SHALL BE FACTORY LABELED PER 2019 BUILDING 1 AND DISCONNECT SCHEDULES
LUMINAIRE, MANHOLE/HANDHOLE,
avates
113
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:51:43PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 05E02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
8660F10 8660F1005E02.dgn
TITLE 24 COMPLIANCE SHEETS 1
114
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:48:17PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 05E03
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
8660F10 8660F1005E03.dgn
TITLE 24 COMPLIANCE SHEETS 2
115
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:55:27PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 05E04
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
8660F10 8660F1005E04.dgn
TITLE 24 COMPLIANCE SHEETS 3
116
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:48:22PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 12E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
POWER GENERATION BUILDING
8660F10 8660F1012E01.dgn
A
01E02
#
GENERAL NOTES:
KEY NOTES:
TYP
EM902
1 TYP
EM173
(TYP)
PLC12199
ANT1-99400 N-5100 2 RAD1-99400 3 N-5000 2
PARTIAL COMMUNICATION PLAN
8660F1012E0101
avates
INSTALLATION.ADDITIONAL INFORMATION WITH REGARDS TO RADIO EQUIPMENT
2. REFER TO NETWORK BLOCK DIAGRAM DRAWING 04N01 FOR
SHALL FIELD VERIFY WHERE NEEDED.AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS
1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PANEL MINIMUM DIMENSIONS SHALL BE 20" H x 20" W x 12" D.DIMENSIONS AND MANUFACTURER RECOMMENDATIONS. RADIO OWNER. SIZE RADIO PANEL ACCORDING TO RADIO EQUIPMENT
3. COORDINATE THE EXACT LOCATION FOR RADIO PANEL WITH
ACCORDING TO EA080/TYP.
2. SUPPORT CONDUIT ON WALL WITH PREFORMED CHANNEL
PROVIDE MINIMUM TWO POINT OF SUPPORT FOR MAST POLE.CHANNEL. WALL ATTACHMENT SHALL BE ACCORDING TO EA080/TYP.
1. MOUNT ANTENNA MAST POLE ON WALL WITH PREFORMED
117
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
B
B
PlotDate:12-JUL-202312:55:10PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 60E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1060E01.dgn
DECHLORINATION STRUCTURE
POWER, CONTROL AND LIGHTING PLAN
STRUCTURE
DECHLORINATION
LCP-60102
DISC-60102
FV-60102
FV-60100
DISC-60100
LCP-60100
A
12'-0"
GENERAL NOTES:
GFCI-WP
A
01E02 3/8" = 1'-0"
# KEY NOTES:
AIT-60101 5
1 3
4 PB-6001
P-60-105
N-60-105
TYP
EM015
P-60-106
C-60-105
2 L-60-110
TYP
EM103
TYP
EM001
TYP
EM211
(TYP)
P-60-107
L
02E02
DWG 01E02
CONTINUED ON
N-60-100
P-60-100
C-60-100
P-60-101
P-60-102
TYP
EL507
PBL70271-29
PNL70271-27
NJB-60001
JGB
SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 3/4".ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE
5. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
IN THE SAME RACEWAY FOR VOLTAGE DROP.AND SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS BE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,
4. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER
3. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS CONDUITS AND WIRING IN A SIMILAR MANNER.ROUTING AS A GUIDE TO INSTALL LIGHTING AND RECEPTACLE SHOWN. USE THE PROCESS POWER AND CONTROL CONDUIT
2. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT
SHALL FIELD VERIFY WHERE NEEDED.AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS
1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER 8660F1060E0101
AND SIGNAL CIRCUITS TO THE NEW UNIT. EQUIPMENT MOUNTING STAND, AND RECONNECT EXISTING POWER
5. MOUNT NEW ANALYZER UNIT INSIDE THE EXISTING CABINET, ON JUNCTION BOX ACCORDING TO NEC.INTERNAL WIRING AND DEVICE INFORMATION. SIZE NETWORK
4. REFER TO DRAWING 04N03 FOR NETWORK JUNCTION BOX
NEC. PULL BOX MINIMUM SIZE SHALL BE 12'W X 8"D X 12"H.
3. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO 2. TO LIGHTING FIXTURES AND RECEPTACLES.
DETAIL EM219/TYP.BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO
1. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING L-60-111
P-60-120X-60-100
N-60-110
X-60-105
avates
L-60-109
118
PB-7001
PB-7002
#4/0 SDBC
STATIONSCADA CONTROL
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
J
PlotDate:12-JUL-202312:49:57PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 70E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
AB
ASH
ELECTRICAL
8660F10 8660F1070E01.dgn
MCC70292
MCC70291
MCC70293
ELECTRICAL ROOM
RESTROOM
FUTURE
GENERAL NOTES:
DAFT BUILDING ELECTRICAL ROOM
4 TYP (TYP)
X-89-111
X-89-113
C-89-120
P-89-121P-89-111
P-89-101
L-89-113
P-89-133
C-91-111
P-91-101
1 TYP (TYP)
EM001
TYP
EM020
(TYP)
2 S-89-102
X-89-103
EM173
L-89-114
C-91-112
P-91-102
P-89-121P-89-111
C-89-120
P-89-101
P-89-134
S-89-103
TYP
EM102
(TYP)
C-89-140
C-89-132
C-89-131
C-89-130
N-70-101
N-70-102
N-70-103
N-70-100
N-70-104
S-80-101
C-87-103
P-89-136
P-89-135P-89-105
P-89-115
P-91-105P-89-125
X-80-100
X-80-101
1 4
M
02E03
DWG 01E02
CONTINUED ON
TYP
EM105
4 DWG01E02
CONTINUEDON
K
02E02
VFD-89102 VFD-89101
VFD-89100
VFD-91100
PLC70299
SWB70282
SWB70281
TYP (TYP)
EG101
# KEY NOTES:
A
01E02 1/4" = 1'-0"
8660F1001E0101
N-60-113
N-60-114
JGB
1 1
3 S350/TYP.MOUNTED ELECTRICAL EQUIPMENT ACCORDING TO DETAIL
2. PROVIDE EQUIPMENT HOUSEKEEPING PAD FOR NEW FLOOR
SHALL FIELD VERIFY WHERE NEEDED.AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS
1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PER DETAIL EG152/TYP. DETAIL EG101/TYP AND EXOTHERMIC CONNECTION SHALL BE CONNECTIONS. COMPRESSION CONNECTION SHALL BE PER CABLE CONNECTION TYPE AND FOLLOW IT TO MAKE THE NEW RING AND BOND NEW EQUIPMENT TO IT. VERIFY EXISTING
4. FIELD VERIFY AND LOCATE EXISTING GROUNDING ELECTRODE CONDUCTORS INSTALLATION.EXISTING CIRCUITS IN PLACE DURING NEW CONDUITS AND
3. EXISTING SIGNAL AND COMMUNICATION PULL BOX. PROTECT
BUILDING.MOUNT PULL BOX ON THE EXTERIOR WALL OF THE DAFT NEC. PULL BOX MINIMUM SIZE SHALL BE 36"W X 26"D X 36"H.
2. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO ACCORDING TO DETAIL EM219/TYP.TRANSITIONING BETWEEN DUCT BANK TO EXPOSED ROUTING
1. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS
POWER, CONTROL, AND GROUNDING PLAN
avates
119
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:53:30PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 80E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HR
SMB
ELECTRICAL
8660F10 8660F1080E01.dgn
A
01E02
LIT-80100
GENERAL NOTES:
SHALL FIELD VERIFY WHERE NEEDED.AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS
1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER PB-8001
TYP
EM103
TYP
EM001
S-80-100
S-80-101
X-80-100
X-80-101
DWG01E02
CONTINUEDON
2 1
M
02E03
# KEY NOTES:
JGB
evandoorn
STRUCTURE 80 PLAN
8660F1080E0101
NO SCALE
ACCORDING TO DETAIL EM219/TYP.TRANSITIONING BETWEEN DUCT BANK TO EXPOSED ROUTING
2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS
10"D X 18"H.ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 18"W X
1. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
120
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:50:16PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 85E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
8660F10 8660F1085E01.dgn
A
01E02
8660F1085E0101
C
85E02 85E03
B
AWT BUILDING OVERALL PLAN
3/16" = 1'-0"
JGB
121
avates
HMI WORKSTATION
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
J
J
J
J
PlotDate:12-JUL-202312:52:41PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 85E02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
8660F10 8660F1085E02.dgn
AWT BUILDING POWER AND CONTROL PLAN 1
MATCHLINESEEDWG85E03
B
85E01
8660F1085E0101
MCC-C
PCM-4
PNL-A
XFMR-A
DP2
STATION
WORK
PMP-85104
PMP-85183
VCP-85183
LCP-85104
S-85-540
C-85-542
C-85-550
S-85-475S-85-415
C-85-402
C-85-457
P-85-221P-85-421
C-85-401
S-85-411
C-85-145
P-85-275P-85-475
C-85-455
S-85-471
C-85-614
C-85-620
C-85-616
PB-8502
PB-8501
PB-8530
2 3
2 P-85-501
C-85-510C-85-520C-85-530
S-85-510S-85-520S-85-530
C-85-501
C-85-507
C-85-503
C-85-505
C-85-511
C-85-517
C-85-515
C-85-513
P-85-521
C-85-523
C-85-521
P-85-511
C-85-525
C-85-527 C-85-540
P-85-710
P-85-612
C-85-612
P-85-610
C-85-610
11 TYP
EM201
TYP (TYP)
EM102
TYP (TYP)
EM163
4 JGB
N-85-500N-85-510
1/4" = 1'-0" -1 1/2" = 1'-0"
8660F1085E0101
PDSH-85106
BLO-85106
FAN-85109
LCP-85108
FAN-85111
BLO-85108
PDSH-85108
PSH-85108
PIT-85108
LCP-85106
PSH-85106
PIT-85106
PIT-85107
PSH-85107
LCP-85107
PDSH-85107
BLO-85107
FAN-85110
PSL-85100
1- P-85-477
P-85-277
P-85-422P-85-222
C-85-542
P-85-501P-85-511
P-87-115
C-87-115
S-88-110
L-88-105
C-85-545
P-85-521
C-87-119
P-87-117P-87-117
S-88-112
C-85-545
S-85-540
VERIFY WHERE NEEDED.FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL FIELD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND SIZES
1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
#
WORK.CONDUIT, CONDUCTORS, AND SWITCH BOXES TO COMPLETE THE PANELBOARD. PROVIDE ALL THE NECESSARY EQUIPMENT SUCH AS
4. RELOCATE EXISTING LIGHTING SWITCH TO MAKE ROOM FOR NEW X 12"H.ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D
3. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
NEC. PULL BOX MINIMUM SIZE SHALL BE 20"W X 12"D X 20"H.
2. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING TO CONDUCTORS TO THE NEW EQUIPMENT.EXISTING POWER, CONTROL, AND SIGNAL CONDUITS AND LOCATED INSIDE VENDOR CONTROL PANEL WITH NEW. RECONNECT
1. REPLACE EXISTING PUMP LOCATED ON PEDESTAL AND PUMP DRIVE GENERAL NOTES:
KEY NOTES:
avates
VCP-3
122
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
B
J B B B J B B B B B J B J B B B
B B J B B J B J
B
B J
B
B
J J J J
B B
PlotDate:12-JUL-202312:51:30PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 85E03
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
EYJ
ELECTRICAL
8660F10 8660F1085E03.dgn
AWT BUILDING POWER AND CONTROL PLAN 2
MATCHLINESEEDWG85E02
C
85E01
8660F1085E0101
DISC-85248
DISC-85249
FV-85249
FCV-85248
FV-85247
FV-85239
FV-85237
FV-85217
FCV-85218
LSH-85104
LSH-85103 LSH-85102 LSH-85101
DISC-85241
DISC-85232
DISC-85231
DISC-85221
DISC-85222
DISC-85211
DISC-85212
FV-85222FV-85212
FCV-85221
FCV-85241 FCV-85231
FV-85242
FCV-85211
LSL-85104
LSL-85103 LSL-85102 LSL-85101
DISC-85247
PB-8514
DISC-85239
DISC-85237
DISC-85238
PB-8513 PB-8512
FV-85219
PB-8511
DISC-85219
DISC-85217
DISC-85218
DISC-85227
DISC-85228
FV-85227
DISC-85229
FCV-85228
FV-85229
FV-85244 FV-85234 FV-85224 FV-85214
PB-8524
PB-8523
PB-8522
PB-8521
DISC-85214
DISC-85244 DISC-85234 DISC-85224
P-85-400
P-85-405S-85-405
S-85-410P-85-410P-85-420
C-85-400
P-85-406
P-85-401P-85-411
P-85-300
P-85-305S-85-305
P-85-310P-85-320
C-85-300
S-85-311
C-85-133
C-85-301
P-85-306
P-85-311P-85-301
P-85-201
P-85-220
C-85-200
S-85-210
P-85-206
P-85-200
P-85-210
C-85-201
S-85-211
C-85-123
P-85-205
S-85-205
P-85-100
P-85-105S-85-105
P-85-110S-85-110
P-85-101
P-85-111
P-85-106
P-85-120
C-85-100
C-85-111
C-85-110
C-85-112
C-85-121
C-85-120
C-85-122
C-85-131
C-85-130
C-85-132
C-85-141
C-85-140
C-85-142
FILTER NO. 4 FILTER NO. 3 FILTER NO. 2 FILTER NO. 1CLARIFIER NO. 4 CLARIFIER NO. 3 CLARIFIER NO. 2 CLARIFIER NO. 1 P-85-150
P-85-155
P-85-160S-85-150
S-85-170
C-85-150
P-85-170
P-85-161
S-85-270
P-85-156
P-85-151
P-85-260
P-85-261
P-85-250S-85-250
P-85-255
P-85-256
P-85-251
S-85-271
C-85-251
C-85-250
S-85-370
P-85-360
P-85-361
P-85-355
P-85-350
P-85-351
P-85-356
S-85-371
C-85-351
S-85-350
P-85-370
S-85-470
P-85-460
P-85-461
P-85-455
P-85-450
P-85-451
P-85-456
P-85-470
C-85-450
S-85-450
#
GENERAL NOTES:
KEY NOTES:
1 3
4 6 6
6 TYP (TYP)
EM211
TYP (TYP)
EM221
6 6
5 5
4 5
6 6
5 6
1 2
JGB
7 7 7 7
P-85-221P-85-421
C-85-401
S-85-411
C-85-145
P-85-275P-85-475
C-85-455
S-85-471 TYP
EM102
FCV-85238
P-85-211
S-85-310
DISC-85242
FV-85232
C-85-350
1/4" = 1'-0"
P-85-270
C-87-115
S-88-110
P-87-115
S-85-400
LIT-85241 LIT-85221 LIT-85211
S-85-300 S-85-200
LIT-85231
S-85-100
P-87-112
C-87-110
C-87-101
P-87-101
S-88-105
S-87-100
PB-8535
R
02E03
8 9 PB-8530
10 ELECTRICAL AND PROCESS EQUIPMENT.MAINTENANCE AND REPAIR IS PROVIDED AROUND AWT FILTER THE OWNER AND ENSURE ADEQUATE SPACE FOR
2. COORDINATE EQUIPMENT MOUNTING STAND LOCATIONS WITH
FIELD VERIFY WHERE NEEDED.SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND
1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
avates
TYP
EM102
8"D X 12"H.ACCORDING TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X
10. SIGNAL AND COMMUNICATION PULL BOX. SIZE PULL BOX
TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D X 12"H.
9. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING 8. DUCT BANKS CONTINUES ONTO DRAWING 01E02.
STRIPS INSIDE THE JUNCTION BOX.CONTRACTOR PROVIDED CONDUCTORS, USING TERMINAL FILTER WALL. TERMINATE LEVEL FLOAT SWITCH CABLE TO
7. PROVIDE A TERMINATION JUNCTION BOX, MOUNTED AT TOP
TO PANELBOARD DP2 SCHEDULE.INSIDE PULL BOX, TO FEED ASSOCIATED ACTUATOR ACCORDING PANELBOARD SHALL SPLICE TO THREE DIFFERENT CIRCUITS ACTUATOR POWER FEEDER CIRCUIT COMING FROM TO NEC. PULL BOX MINIMUM SIZE SHALL BE 12"W X 8"D X 12"H.
6. POWER AND CONTROL PULL BOX. SIZE PULL BOX ACCORDING
WITH PREFORMED CHANNEL ACCORDING TO DETAIL EA030/TYP.
5. MOUNT DISCONNECT SWITCH ON THE FILTER EXTERIOR WALL
WASTE GATES.ASSOCIATED WITH ALL FILTERS, LEVEL INSTRUMENTS, AND FILTER EXTERIOR WALLS. THIS IS TYPICAL FOR CONDUITS
4. SUPPORT CONDUITS WITH PREFORMED CHANNELS ON THE
THE FILTER EXTERIOR WALL ACCORDING TO DETAIL EA030/TYP.EM104/TYP. OR SUPPORTED WITH PREFORMED CHANNEL ON SUPPORTED ON THE GROUND ACCORDING TO DETAIL
3. CONDUIT ROUTING ON THE EAST SIDE OF FILTERS SHALL BE CHANNEL ACCORDING TO DETAIL EA060/TYP.SUPPORTED UNDER THE PLATFORM WITH PREFORMED
2. CONDUIT ROUTING ON THE WEST SIDE OF FILTERS SHALL BE CEILING LEVEL.
1. CONDUITS FROM THE WEST SIDE OF TANK SHALL RISE TO
123
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
JJ
PlotDate:12-JUL-202312:53:37PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 87E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1087E01.dgn
A
01E02
8660F1087E0101
POWER AND CONTROL PLAN
BACKWASH PUMP STATION
GENERAL NOTES:
VERIFY WHERE NEEDED.FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR SHALL FIELD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS AND SIZES
1. EXISTING EQUIPMENT AND SIZES ARE FROM OWNER RECORD
NO SCALE
# KEY NOTES:
AIT-87130
PMP-87134
LCP-87134 2
TYP (TYP) P
02E03
EM001
S-87-100
C-87-101
P-87-101
C-87-100
P-87-100
TYP
EM104
1 TYP (TYP)
EM201
JGB
avates
3 DWG01E02
CONTINUED ON
DWG01E02
CONTINUED ON
3 Q
02E03
TYP (TYP)
EM015
L-88-102
L-88-101
S-88-102
S-88-101
3. GROUND NEW DUCT BANK TO EXISTING GROUND RING.
DETAIL EM219/TYP.BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO
2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING CONDUCTOR TERMINATION POINT.CONDUCTORS AS LONG AS NEEDED TO REACH EQUIPMENT CIRCUITS TO THE NEW UNIT. EXTEND POWER CONDUITS AND EQUIPMENT MOUNTING STAND, AND RECONNECT EXISTING POWER
1. MOUNT NEW ANALYZER UNIT ON THE EXISTING ANALYZER
DWG01E02
CONTINUEDON
FV-87130
C-87-105
FV-87130
124
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
JJ
J
PlotDate:12-JUL-202312:53:06PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 89E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1089E01.dgn
A
01E02 1/2"=1'-0"
8660F1089E0101
DWG01E02
CONTINUEDON
DWG 01E02
CONTINUED ON
02E01
# KEY NOTES:
1 33
5 4
PMP-89100
LCP-89100
LCP-89101
PMP-89101
LCP-89102
PMP-89102
PB-8901
GENERAL NOTES:
I
02E02
L
TRF-3E
CAROUSEL PUMP STATION
POWER AND CONTROL PLAN
X-89-100
P-89-131P-89-101P-89-111
P-89-121
C-89-120
L-89-111
S-89-101X-89-101
2 L-60-111
P-60-120X-60-100
N-60-110
2 C-89-120
S-89-100
L-89-110
L-89-120
P-89-130P-89-100P-89-110
TYP P-89-120 (TYP)
EM020
TYP (TYP)
EM211
TYP (TYP)
EM104
C-89-101
C-89-102
C-89-100
3 FSL-89102
C-89-108
C-89-113
TYP (TYP)
EM201
C-89-116
C-89-115
C-89-111
C-89-110
LIT-89103
LSLL-89100
C-89-106C-89-107
FSL-89101
FSL-89100
X-89-120
X-89-125
N-60-111
X-60-105
-1 KVA TRANSFORMER- MOTOR CONTROL CABINET- MAIN DISCONNECT SWITCH, 200 A, 3-POLEELECTRICAL EQUIPMENT TO BE DEMOLISHED:
2. REFER TO DRAWING 89D01 FOR LOCATION OF FOLLOWING
SHALL FIELD VERIFY WHERE NEEDED.AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS
1. EXISTING EQUIPMENT LOCATIONS AND SIZES ARE FROM OWNER
TYP (TYP)
EM105
JGB
6. TO LIGHTING FIXTURES AND RECEPTACLES.
CONDUCTORS ON LINE SIDE OF DISCONNECT SWITCH.DIVERSION METERING VAULT FLOW METER FIT-99105. TERMINATE
5. DISCONNECT SWITCH IS FOR 120V POWER SOURCE TO FLOW
CONDUCTORS ON LINE SIDE OF DISCONNECT SWITCH.DIVERSION METERING VAULT ACTUATED VALVES. TERMINATE
4. DISCONNECT SWITCH IS FOR 480V POWER SOURCE TO FLOW 3. REPLACE EXISTING PUMP MOTOR WITH NEW MOTOR.
DETAIL EM219/TYP.BETWEEN DUCT BANK TO EXPOSED ROUTING ACCORDING TO
2. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING EAST.POWER/CONTROL CIRCUITS. ACCESS DOORS SHALL BE FACING PULLING SPACE BETWEEN SIGNAL/COMMUNICATION AND BOX WITH SEPARATE ACCESS DOORS AND SEPARATE THE CABLE SHALL BE 30"W X 20"D X 30" H. PROVIDE A DIVIDER INSIDE THE PULL PULL BOX ACCORDING TO NEC. PULL BOX MINIMUM DIMENSIONS
1. POWER, CONTROL, SIGNAL AND COMMUNICATION PULL BOX. SIZE DWG01E02
CONTINUEDON
6 TYP
EM020
(TYP)
2 avates
LSHH-89100
125
#6 SDBC
#4/0 SDBC
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:53:25PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 89E02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1089E02.dgn
B
01E02 1/2"=1'-0"
8660F1089E0201
DWG01E02
CONTINUEDON
DWG 01E02
CONTINUED ON
02E01
PMP-89100
PMP-89101
PMP-89102
GENERAL NOTES:
I
02E02
L
TRF-3E
CAROUSEL PUMP STATION LIGHTING,
TYP (TYP)
EG002
TYP
EG204
TYP
EG101
(TYP)
GFCI-WP
A
12'-0"
GFCI-WP
A
12'-0"
2 TYP
EG001
(TYP)
# KEY NOTES:
GROUNDING EQUIPMENT ARE NOT IN ADEQUATE CONDITION.THE EXISTING GROUND RING AND GROUND RODS IF EXISTING GROUND RING ASSOCIATED WITH THE PUMP STATION. REPLACE
5. FIELD VERIFY CONDITION, LAYOUT AND INTEGRITY OF THE EXISTING INCHES.SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 0.75 ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE
4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND
3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER
2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A
1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN. evandoorn
1 1 PNL70271-27
PNL70271-29
PNL70271-29
PNL70271-27
JGB
GROUNDING, AND RECEPTACLES PLAN
2. TYPICAL FOR ALL CAROUSEL PUMP MOTOR.
CONDUCTOR ACCORDING TO DETAIL EG101/TYP.
1. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
126
#4/0 SDBC
PB-9101
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
PlotDate:12-JUL-202312:52:25PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 91E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
ASH
ELECTRICAL
8660F10 8660F1091E01.dgn
A
01E02
8660F1091E0101
POWER AND CONTROL
PMP-91100
B
01E02
8660F1091E0201
A
12'-0"
GFCI-WP
3/8"=1'-0" 3/8"=1'-0"
H
3 LSHH-91101
LSL-91101
L-91-100
X-91-102
C-91-105
C-91-106
P-91-101
C-91-110
X-91-100
LCP-91100
02E01
TYP
TYP (TYP)
TYP (TYP)
TYP
TYP
TYP
EM020
EM105
EM211
EM115
EG001
EL507
TYP (TYP)
EG101
TYP (TYP)
EG002
PMP-91100
1 2
3 FSL-91100
DWG 01E02
CONTINUED ON
DWG 01E02
CONTINUED ON
TYP
EM201
C-91-104
TYP
EM139
PNL70271-27
PNL70271-29
LIGHTING AND GROUNDING
JGB
PAU PUMP STATION PLANS
C-91-100
P-91-100
avates
INCHES. SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THE 0.75 ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE
4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP. SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND
3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA. TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER
2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER. GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A
1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN, #
CONDUCTOR AS PER DETAIL EG101/TYP.
4. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
EM219/TYP.BETWEEN DUCT BANK TO EXPOSED ROUTING AS PER DETAIL
3. PROVIDE EXPANSION FITTINGS FOR ALL CONDUITS TRANSITIONING NEC. PULL BOX MINIMUM SIZE SHALL BE 22"W X 12"D X 22" H.
2. POWER AND CONTROL PULL BOX SIZE PULL BOX ACCORDING TO 1. TO LIGHTING FIXTURES AND RECEPTACLES.
GENERAL NOTES:
KEY NOTES:
4 H
02E01
127
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:49:40PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 99E01
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
EXISTING WATER TREATMENT BUILDING
8660F10 8660F1099E01.dgn
A
02E01
XFMR-A
GEN-A
MCC-E
ATS-E
MCC-XFR
VFD-XFR
MCC-N
SWBD-A
ROOM
ELECTRICAL
JGB
# KEY NOTES:
PNL-RWPS
2 1--PNL-RWPS
1 2
1 1- MCC-E 2- PNL-RWPS
X-0010
X-0011
P-0010
P-0011
3 4
6 TYP
EM001
P-0001
P-0002
5 6
3- 8660F1099E01C
ELECTRICAL ROOM ATTIC
7 7
GENERAL NOTES:
3- SHALL FIELD VERIFY WHERE NEEDED.
AND SIZES FOR EXISTING EQUIPMENT IN FIELD. CONTRACTOR RECORD DRAWINGS, AND MAY NOT REFLECT EXACT LOCATIONS
1. EXISTING EQUIPMENT LOCATION AND SIZES ARE FROM OWNER
PARTIAL POWER AND CONTROL PLAN
8660F1099E01A 8660F1099E01B
WORK RESTRICTIONS.CONDUIT WORK. REFER TO SPECIFICATION SECTION 01140 FOR CONDUITS. PROTECT EXISTING CABLES AND RE-TERMINATE AFTER
7. IF NEEDED FOR TOP HAT CONSTRUCTION, RELOCATE EXISTING STRUCTURAL ENGINEER OF RECORD FOR DIRECTION.MODIFICATION TO CEILING JOISTS IS NEEDED, CONTACT MOUNTING SPACE IS OBSTRUCTED BY CEILING JOISTS, AND DETERMINED DURING FIELD VERIFICATION THAT ENCLOSURE CONDUIT ENTRY, AND ACCESS LOCATION WITH EATON. IF IT IS JOISTS. COORDINATE NEW TOP HAT ENCLOSURE ACTUAL SIZE, THAN 8" MAY NEED TO BE PARTIALLY PLACED IN CEILING, BETWEEN
6. HEAD SPACE ABOVE MCC IS APPROXIMATELY 8". TOP HAT HIGHER ROOM. SUPPORT CONDUITS IN ATTIC SPACE PER DETAIL EM901/TYP.
5. ROUTE CONDUITS THROUGH ATTIC SPACE ABOVE ELECTRICAL
CHANNELS ACCORDING TO DETAIL EM903/TYP.
4. SUPPORT CONDUITS ON BUILDING SIDE WALL WITH PREFORMED ELECTRICAL BUILDING.EM219/TYP, AND ENTER TO THE BUILDING'S ATTIC SPACE, ABOVE
3. CONDUITS RISE FROM DUCT BANK PER DETAIL EM020/TYP AND SPACE FOR PNL-RWPS INSTALLATION.
2. RELOCATE SPD ENCLOSURE IF NEEDED TO PROVIDE ADEQUATE SHALL SUBMIT TOP HAT AND TAP DESIGN FOE ENGINEER REVIEW.SERVICES TO COMPLETE TOP HAT INSTALLATION. CONTRACTOR MCC-E. CONTRACTOR TO PROVIDE MANUFACTURER FIELD PARTS AND ACCESSORIES TO COMPLETE CABLE TERMINATION IN BE THE SAME AS EXISTING MCC-E. PROVIDE ALL THE NECESSARY POWER CABLES. ENCLOSURE MANUFACTURER AND MODEL SHALL ACCOMMODATE NEW TAP OF EXISTING MCC-E BUS WITH PNL-RWPS
1. PROVIDE MCC TOP HAT ENCLOSURE TO HOUSE PNL-RWPS POWER.
DWG 01E01
CONTINUED ON
A
01E01 1/4" = 1'-0"
8660F1099E0101
128
avates
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
BB
PlotDate:12-JUL-202312:47:10PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1099E02.dgn
99E02
# KEY NOTES:
1 PNL-RWPS-L XFMR-RWPS-L
PCM-99400
SWBD-RWPS VFD-99414 VFD-99413 VFD-99412 VFD-99411
RECYCLED WATER ELECTRICAL BUILDING
POWER AND CONTROL PLAN
JGB
CONTINUEDONDWG99E03
A CONTINUED ON DWG 01E01
02E01
C
02E01
TYP (TYP)
EM001
3 X-3200X-3100
X-3104
X-2100
X-1502
P-2012
C-2015
S-2011X-2011
P-2022
C-2025
S-2021X-2021
N-2021
P-2032
C-2035
S-2031X-2031
P-2042
C-2045
S-2041X-2041
N-2041
X-2056
X-2052
X-2053
X-2054
X-2051
X-2055
P-2043P-2033P-2023P-2013
TYP
EM020
TYP (TYP)
EM022 2
N-2011
P-0010
P-0011
P-1000
X-0010
X-0011
L-1102
DISC-99421
L-1101
CU-99421
L-1110L-1100
CU-99422
TYP
EM173
DISC-99422
L-1112
L-1111
TYP
EM107
TYP (TYP)
EM033
N-3100
N-1000
RAD2-99400
S-3102
L-1000
C-3105
L-3200
L-3102
L-2100
X-2101
L-1200
L-1201
N-2031
GENERAL NOTES:
S-2431
L-2431
X-1501
X-1500
N-2001
55 4
EM102/TYP AND EA030/TYP.
3. SUPPORT EXPOSED CONDUITS AS NEEDED ACCORDING TO DETAILS BOTTOM OF ENCLOSURE.ROOM WITH ELECTRICAL EQUIPMENT CONDUIT ENTRY OPENING AT
2. COORDINATE CONDUIT STUB UP LOCATIONS INSIDE ELECTRICAL CROSS IN CONCRETE SLAB.DIAMETER LARGER THAN TWO INCHES SHALL NOT STACK OR EM115/TYP, EM116/TYP, AND EM117/TYP. EMBEDDED CONDUITS WITH
1. EMBEDDED CONDUIT IN SLAB SHALL BE INSTALLED PER DETAILS B
01E01 3/4" = 1'-0"
8660F1099E0101
FCU-99421 FCU-99422
S-3101
C-3102
6 DIMENSIONS SHALL BE 20" H x 20" W x 12" D.AND MANUFACTURER RECOMMENDATIONS. RADIO PANEL MINIMUM
6. SIZE RADIO PANEL ACCORDING TO RADIO EQUIPMENT DIMENSIONS ANY CHANGES TO ENGINEER FOR REVIEW.BREAKER RATING AND CABLE SIZE ACCORDINGLY PER NEC. SUBMIT PROTECTION RATING FOR HVAC UNIT, AND CHANGE CIRCUIT
5. CONTRACTOR SHALL VERIFY MAXIMUM OVER CURRENT
MANUFACTURER INSTALLATION REQUIREMENTS.NECESSARY CONDUITS AND CABLES ACCORDING TO
4. CONTRACTOR SHALL INSTALL THERMOSTAT, AND PROVIDE
BUILDING SLAB AND TOP OF THE DUCT BANK.
3. PROVIDE MINIMUM OF 6" SPACE BETWEEN BOTTOM OF THE
LOCATION.
2. CONDUITS SHALL REMAIN ENCASED IN DUCT BANK TO STUB UP 1. SPACE IS RESERVED FOR FUTURE RECYCLED PUMP VFD. avates
X-3101
129
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
S
J
S
J
S
J
S
J
PlotDate:12-JUL-202312:47:16PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
CLH
ELECTRICAL
8660F10 8660F1099E03.dgn
RECYCLED WATER PUMP STATION
99E03
LCP-99411 PMP-99411 PMP-99412 PMP-99413 PMP-99414
FIT-99431
POWER AND CONTROL PLAN
FSL-99411 FSL-99412 FSL-99413 FSL-99414
JGB
DISC-99411
P-2012
S-2011X-2011
C-2015
C-2019
TYP
(TYP)
EM202
1 TYP
(TYP)
EM020
2 TYP
EM032
3 C
02E01
D
02E01
L-2100
C-2013
C-2012
C-2011
P-2011
DISC-99412
P-2022
S-2021X-2021
C-2025
C-2029
C-2023
C-2022
C-2021
LCP-99412
DISC-99413
P-2032
S-2031X-2031
C-2035
C-2039
C-2033
C-2032
C-2031
LCP-99413
P-2042
S-2041X-2041
C-2045
C-2049
C-2043
C-2042
C-2041
P-2021 P-2031 P-2041
TYP
EM115
(TYP)
X-2051
X-2052
X-2053
X-2054
X-2101
S-2431 X-2100
L-2431
TYP
EM001
(TYP)
S-2430
S-2429 PIT-99432
C
01E01 1/2" = 1'-0"
8660F1099E0102
DISC-99414
LCP-99414
TYP
EM105
(TYP)
CONTINUEDONDWG99E02
CONTINUEDONDWG99E04
4 4 4 4
WITH MAXIMUM 2' OF TYPE LIQUID-TYPE FLEXIBLE CONDUIT.
1. FINAL CONDUIT CONNECTION TO PUMP MOTOR SHALL BE MADE #
ENTERING TO THE PUMP TERMINATION BOX.
4. COMBINE POWER AND CONTROL CONDUITS INTO ONE CONDUIT 3. TO PUMP STATION LIGHTING FIXTURES AND RECEPTACLES.
LOCATION.
2. CONDUITS SHALL REMAIN ENCLOSED IN DUCT BANK TO STUB UP ASSOCIATED JUNCTION BOXES, ON THE SAME EQUIPMENT STAND.
1. MOUNT ELECTRICAL DISCONNECT, LOCAL CONTROL PANEL, AND GENERAL NOTES:
KEY NOTES:
130
avates
HH-4
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
J
J
J
J
PlotDate:12-JUL-202312:49:02PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 99E04
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLU
ELECTRICAL
8660F10 8660F1099E04.dgn
RECYCLED WATER STORAGE POWER AND CONTROL
SV1-99402SV2-99402
DWG 99E03
CONTINUED ON
JGB
TYP
EM001
(TYP)
TYP
(TYP)
EM020
TYP
EM202
S-3100 2
C-3100 2
TYP
EM015
ANT2-99400
TYP
EM902
4 F
02E01
5 TYP
EM201
L-3101
X-3100
X-3101
S-3101
C-3102
N-3100
L-3200
S-3200
C-3005
C-3001
C-3003
# KEY NOTES:
5 FIT-99406
C-3002
ZSOC-99402
X-3102
X-3103
TYP
EM315
D
02E01
D
01E01 1/8" = 1'-0"
8660F1099E0104
E
02E01 L-3100
avates
1 LIT-99405
LSHH-99403
LSLL-99403
6 3 DESIC-99405
TERMINATE LEVEL INSTRUMENT CABLES ON IT.PROVIDE TERMINAL STRIP INSIDE THE JUNCTION BOX AND
6. MOUNT JUNCTION BOX ON THE ROOF NEAR LEVEL INSTRUMENTS. 10E14.
5. LIGHTING AND RECEPTACLE CONDUIT CONTINUES ON DRAWING LUGS.
4. SUPPORT ANTENNA MAST POLE ON TANK EMBEDDED SUPPORT
PROVIDE SST SUN SHADE FOR THE BOX.
3. DESICCANT JUNCTION BOX MINIMUM SIZE SHALL BE 6" x 6" x 6".
EMBEDDED SUPPORT LUGS.
2. SUPPORT CONDUITS WITH PREFORMED CHANNEL ON TANK 1. INSTALL CONDUIT SLEEVE FOR LEVEL INSTRUMENT CABLES. 131
#4/0 SDBC
#8 SDBC
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
Model:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 99E12
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
RECYCLED WATER ELECTRICAL BUILDING
LIGHTING, GROUNDING AND RECEPTACLES PLAN
8660F10 8660F1099E12.dgn
RWPS-2
RWPS-3
GFCI-WP
RWPS-3
GFCI-WP
RWPS-2
RWPS-2
RWPS-3GFCI-WP
TYP (TYP)
EG002
TYP
EG304
TYP (TYP)
EG205
TYP (TYP)
EG102
TYP (TYP)
EM725
TYP (TYP)
EG511
TYP
EG205
TYP (TYP)
EG101
TYP (TYP)
EG001
3 4
1 3
6 5
1 TYP
EL200
TYP
EA030
(TYP)
22 6
4 B
9'-0"
a RWPS-1
B
9'-0"
a RWPS-1
B
9'-0"
a RWPS-1
C
9'-0"RWPS-1
RWPS-1
D
10'-0"
C
9'-0"RWPS-1RWPS-1
D
10'-0"
#
GENERAL NOTES:
KEY NOTES:
VFD-99414 VFD-99413
RAD2-99400
PCM-99400 PNL-RWPS-L XFMR-RWPS-L
SWBD-RWPS VFD-99412 VFD-99411
CONTINUED ON DWG 01E01
CONTINUEDONDWG99E13
CU-99422
CU-99421
INCHES.SPECIFICATIONS. CONDUITS SHALL NOT BE SMALLER THAN 0.75 ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE
5. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
CONDUCTORS IN THE SAME RACEWAY AND FOR VOLTAGE DROP.AND SHALL BE DE RATED TO ACCOUNT FOR MULTIPLE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE,
4. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE 3. LIGHTING PANEL PNL-RWPS-L IS ABBREVIATED AS RWPS.
AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER
2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A
1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN. 7 ELECTRICAL
E
01E01 3/4" = 1'-0"
8660F1099E0201
a
RWPS-1
3, D
a
RWPS-1
3,D
7. TYPICAL FOR HVAC CONDENSER UNIT.
FIXTURE.
6. PROVIDE EMERGENCY BACKUP LIGHTING PACKAGE FOR THIS 5. SPACE IS RESERVED FOR FUTURE RECYCLED PUMP VFD.4. CONTINUED ON SHEET 10E13.
CONDUCTOR ACCORDING TO DETAIL EG101/TYP.
3. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING 2. BOND HVAC EQUIPMENT TO THE GROUND RING CONDUCTOR.
CONDUIT AT EXPOSED LOCATIONS.CONDUCTOR INSIDE MINIMUM SIZE 1-1/2" SCHEDULE 80 PVC WITH COMPRESSION CONNECTION. INSTALL GROUNDING
1. BOND CEILING METALLIC BEAM TO THE GROUND RING CONDUCTOR C
02E01
A
02E01
avates
132
#4/0 SDBC
#6 SDBC
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:48:41PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
RECYCLED WATER PUMP STATION
LIGHTING, GROUNDING, AND RECEPTACLES PLAN
8660F10 8660F1099E13.dgn
99E13
PMP-99411 PMP-99412 PMP-99413 PMP-99414
RWPS-5
GFCI-WP
RWPS-5GFCI-WP
RWPS-5GFCI-WP
RWPS-5
GFCI-WP
A
12'-0"RWPS-4
A
12'-0"RWPS-4
A
12'-0"RWPS-4
A
12'-0"RWPS-4
2 2
1 3
TYP S
EL507
TYP
EG101
(TYP) TYP
EG002
(TYP)
#
GENERAL NOTES:
KEY NOTES:
5. LIGHTING PANEL PNL-RWPS-L IS ABBREVIATED AS RWPS.
INCHES.SPECIFICATIONS. CONDUIT SHALL NOT BE SMALLER THAN 0.75 ACCORDANCE WITH THE CONDUIT FILL REQUIREMENTS IN THE
4. LIGHTING AND RECEPTACLE CONDUITS SHALL BE SIZED IN
SAME RACEWAY FOR VOLTAGE DROP.SHALL BE RATED TO ACCOUNT FOR MULTIPLE CONDUCTORS IN THE SIZED IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE, AND
3. CONDUCTORS FOR LIGHTING AND RECEPTACLE CIRCUITS SHALL BE AND CONTROL CONDUIT INSTALLATION WITHIN THE SAME AREA.TYPES SHALL BE THE SAME AS THOSE FOR THE PROCESS POWER
2. LIGHTING AND RECEPTACLE CONDUITS, AND CONDUIT FITTINGS WIRING IN A SIMILAR MANNER.GUIDE TO INSTALL LIGHTING AND RECEPTACLE CONDUITS AND USE THE PROCESS POWER AND CONTROL CONDUIT ROUTING AS A
1. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE IS NOT SHOWN.
TYP
NF136
4 4. TYPICAL FOR ALL RECYCLED WATER PUMP MOTOR.3. FOR FUTURE PUMP INSTALLATION.2. CONTINUED ON SHEET 10E12.
PUMP MOTORS.INSTALLATION MANUAL. THIS IS TYPICAL FOR ALL RECYCLED WATER
1. BOND MOTOR FRAME ACCORDING TO NEC AND MANUFACTURER
TYP
EL502
F
01E01 3/8" = 1'-0"
8660F1099E0202
DWG99E14
CONTINUEDON
DWG98E12
CONTINUEDON
D
02E01
C
02E01
133
avates
HH-4
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
PlotDate:12-JUL-202312:51:33PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 99E14
LASTSAVEDBY:
PROJECT NO. FILE NAME:
HQR
PLK
JGB
ELECTRICAL
RECYCLED WATER STORAGE
LIGHTING, GROUNDING, AND RECEPTACLES PLAN
8660F10 8660F1099E14.dgn
RWPS-5
GFCI-WP
2 2
1 A
RWPS-1115'-0"
A
RWPS-1114'-0"
TYP (TYP)
EL506
TYP (TYP)
EG002
ANT2-99400
# KEY NOTES:
TYP (TYP)
EG101
TYP
NF136
D
02E01
E
02E01
F
02E01
G
01E01 1/8" = 1'-0"
8660F1099E0204
DWG 99E13
CONTINUED ON
10E04.
2. LIGHTING AND RECEPTACLE CONDUIT CONTINUES ON DRAWING CONDUCTOR ACCORDING TO DETAIL EG101/TYP.
1. BOND DUCT BANK GROUNDING WIRE TO THE GROUND RING
avates
TYP
EL506
134
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
SYMBOL DRAWING VISIBLE FIELDS FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5 FIELD - 6 FIELD - 7 FIELD - 8 INSTRUMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTINGPRIMARY ELEMENT 2 -LOOP NUMBER BUILDING NO. F -FUTURE 3 -FUNCTION ROOM NO.4 -FURNISHED BY5 -LOCATION6 -EXISTING/FUTURE INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTING OUT -OUTDOORCONTROL ELEMENT 2 -LOOP NUMBER INT -INTEGRAL F -FUTUREPRIMARY FUNCTION 3 -FUNCTION REM -REMOTEOPERATOR 4 -FURNISHED BYACCESSIBLE 5 -DESCRIPTION 6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTINGCONTROL ELEMENT 2 -LOOP NUMBER F -FUTUREAUXILIARY FUNCTION 3 -FUNCTIONOPERATOR 4 -FURNISHED BYACCESSIBLE 5 -LOCATION 6 -EXISTING/FUTURE
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTINGCONTROL ELEMENT 2 -LOOP NUMBER F -FUTUREPRIMARY FUNCTION 3 -FUNCTIONOPERATOR 4 -FURNISHED BYINACCESSIBLE 5 -LOCATION XR -PROTECTION 6 -EXISTING/FUTURE RELAY
CR -CONTROL
RELAY
XR -INTERPOSING
RELAY
INSTRUMENT/ 1 -TAG REFER REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTINGCONTROL ELEMENT 2 -LOOP NUMBER F -FUTUREAUXILIARY FUNCTION 3 -FUNCTIONOPERATOR 4 -FURNISHED BYINACCESSIBLE 5 -LOCATION XR -PROTECTION 6 -EXISTING/FUTURE RELAY
CR -CONTROL
RELAY
XR -INTERPOSING
RELAY
FIELD EQUIPMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTINGNON-POWERED 2 -LOOP NUMBER BUILDING NO. F -FUTURE 3 -FUNCTION/SIZE ROOM NO.4 -FURNISHED BY5 -LOCATION6 -EXISTING/FUTURE FIELD EQUIPMENT 1 -TAG REFER REFER DESCRIPTION DESCRIPTION AREA NO. E -EXISTINGPRIMARY FUNCTION 2 -LOOP NUMBER BUILDING NO. F -FUTUREPOWERED 3 -FUNCTION ROOM NO. 4 -FURNISHED BY5 -LOCATION6 -EXISTING/FUTURE
FIELD EQUIPMENT 1 -TAG MWH-MOTOR REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTINGAUXILIARY FUNCTION 2 -LOOP NUMBER WINDING F -FUTUREPOWERED 3 -FUNCTION HEATER 4 -FURNISHED BY TSH -TEMPERATURE5 -LOCATION SWITCH6 -EXISTING/FUTURE XSH -TORQUE SWITCH
FIELD EQUIPMENT 1 -TAG MS -MOTOR REFER FVNR -FULL VOLTAGE 120VAC -1P LCP -LOCAL CONTROL E -EXISTINGSTARTER/DRIVE 2 -LOOP NUMBER STARTER NON-REVERSING STARTER 208VAC -2P PANEL NO. F -FUTURECUBICLE/CABINET 3 -TYPE RVAT-REDUCED FVR -FULL VOLTAGE 208VAC -3P MCC -MOTOR CONTROL 4 -VOLTAGE-POLE VOLTAGE AUTO REVERSING STARTER 240VAC -2P CENTER NO.5 -POWER SOURCE TRANSFORMER PWS -PART-WINDING STARTER 240VAC -3P PCM -PROCESS CONTROL6 -EXISTING/FUTURE STARTER RVAT -REDUCED VOLTAGE AUTO 480VAC -3P MODULE NO.
RVSS-REDUCED RVSS -REDUCED VOLTAGE 2400VAC -3P VCP -VENDOR CONTROL VOLTAGE SOLID STATE STARTER 4160VAC -3P PANEL NO.SOLID STATE TS1W -TWO SPEED SINGLESTARTER WINDING VFD -VARIABLE TS2W -TWO SPEED TWO WINDINGS
FREQUENCY VFD -VARIABLE FREQUENCYDRIVE DRIVE
INSTRUMENT BUBBLE LOCATIONS NOTES
PCS
INSTRUMENT TAG IDENTIFICATION LETTERS TABLEOPERATOR PILOT DEVICE LEGEND
I/OEQUIPMENT TAGGING TABLE
I/O TYPE DESIGNATIONS
OPERATOR
INTERFACE/
CONTROL
DEVICESINSTRUMENT TYPE DESIGNATIONS TABLE
FURNISHED BY: FBO FURNISHED BY OWNER
FBV FURNISHED BY VENDOR
POWER
SOURCEPROVIDED BY: PBO PROVIDED BY OWNER
PBV PROVIDED BY VENDOR
FIELD
SYMBOL DRAWING VISIBLE FIELDS FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5 FIELD - 6 FIELD - 7 FIELD - 8 HMI/SCADA SYSTEM 1 -TAG REFER REFER ACTION DESCRIPTION DESCRIPTION E -EXISTINGOPERATOR 2 -LOOP NUMBER ALARM F -FUTUREINTERFACE 3 -FUNCTION SP -NUMERICTERMINAL 4 -DESCRIPTION STATUS -SET POINT 5 -DESCRIPTION TREND6 -EXISTING/FUTURE
HARDWIRED I/O 1 -TAG REFER REFER AI -ANALOG INPUT DESCRIPTION PAC -PROGRAMMABLE E -EXISTINGPOINT 2 -LOOP NUMBER AO -ANALOG OUTPUT AUTOMATION F -FUTURE 3 -FUNCTION DI -DISCRETE INPUT CONTROLLER NO.4 -DESCRIPTION DO -DISCRETE OUTPUT PLC -PROGRAMMABLE5 -LOCATION RTD -RTD INPUT LOGIC6 -EXISTING/FUTURE CONTROLLER NO.7 -IO TABLE RIO -REMOTE I/O
VCP -VENDOR CONTROL
PANEL NO.
NETWORK / SOFT I/O 1 -TAG REFER REFER COMMUNICATION PROTOCOL DESCRIPTION PAC -PROGRAMMABLE E -EXISTING 2 -LOOP NUMBER CNET -CONTROLNET AUTOMATION F -FUTURE3 -PROTOCOL DNET -DEVICENET CONTROLLER NO.4 -PANEL EIP -ETHERNET/IP PLC -PROGRAMMABLE5 -PLC FF -FOUNDATION FIELDBUS LOGIC6 -EXISTING/FUTURE HART-I -HART OVER ETHERNET CONTROLLER NO.7 -IO TABLE MANF -MFR. PROPRIETARY RIO -REMOTE I/O8 -SWITCH/SEGMENT MBRTU -MODBUS RTU VCP -VENDOR CONTROL MB+ -MODBUS PLUS PANEL NO.MBTCP -MODBUS TCPDP -PROFIBUS DPPA -PROFIBUS PAPNET -PROFINETSNMP -SNMPv3HTTP -WEB SERVER (TCP/IP) LOCAL 1 -TAG REFER REFER ACTION DESCRIPTION LOI -LOCAL OPERATOR E -EXISTINGOPERATOR 2 -LOOP NUMBER ALARM INTERFACE NO. F -FUTUREINTERFACE 3 -FUNCTION SP -NUMERIC LCP -LOCAL CONTROL 4 -DESCRIPTION STATUS -SET POINT PANEL NO.5 -LOCATION TREND PCM -PROCESS CONTROL6 -EXISTING/FUTURE MODULE NO.
VCP -VENDOR CONTROL
PANEL NO.
PILOT DEVICE 1 -TAG REFER REFER AM -AUTO/MANUAL DESCRIPTION LCP -LOCAL CONTROL E -EXISTINGOPERATOR 2 -LOOP NUMBER BYPASS -BY PASS PANEL NO. F -FUTUREINTERFACE 3 -FUNCTION E-STOP -EMERGENCY STOP MCC -MOTOR CONTROL 4 -DESCRIPTION FRLR -FIXED RATE/LEVEL RATE CENTER NO.5 -LOCATION HOA -HAND/OFF/AUTO PCM -PROCESS CONTROL6 -EXISTING/FUTURE LOR -LOCAL/OFF/REMOTE MODULE NO.
LOS -LOCK OUT STOP RVS -REDUCED VOLTAGELS -LEAD/STANDBY SOLID STARTER NO.LSR -LOCAL/STOP/REMOTE VCP -VENDOR CONTROLNOOT -NO OFFLINE/OFFLINE PANEL NO.
TRANSITION VFD -VARIABLE
OC -OPEN/CLOSE FREQUENCYOLOL -ON LINE/OFFLINE DRIVE NO.OO -OFF/ONOSC -OPEN/STOP/CLOSERST -RESETSAAM -SEMI AUTO/AUTO/MANUALSEL -SELECTSPD -SPEEDSS -START/STOPST -STOP POWER DEVICE 1 -TAG CB -CIRCUIT REFER TM -THERMAL MAGNETIC 24VDC -1P DP -DISTRIBUTION E -EXISTINGPRIMARY FUNCTION 2 -LOOP NUMBER BREAKER CIRCUIT BREAKER 24VDC -2P PANEL NO. F -FUTUREOPERATOR 3 -FUNCTION DISC -DISCONNECT 24VAC -1P LCP -LOCAL CONTROLACCESSIBLE 4 -VOLTAGE-POLE FU -FUSE 48VDC -2P PANEL NO. 5 -LOCATION 120VAC -1P LP -LIGHTING PANEL NO.6 -EXISTING/FUTURE 208VAC -2P MCC -MOTOR CONTROL 208VAC -3P CENTER NO.240VAC -2P PCM -PROCESS CONTROL240VAC -3P MODULE NO.480VAC -3P PP -POWER PANEL NO.2400VAC -3P VCP -VENDOR CONTROL4160VAC -3P PANEL NO.
POWER DEVICE 1 -TAG DISC -DISCONNECT REFER DESCRIPTION DESCRIPTION DESCRIPTION E -EXISTINGAUXILIARY FUNCTION 2 -LOOP NUMBER F -FUTUREOPERATOR 3 -DESCRIPTIONACCESSIBLE 4 -DESCRIPTION 5 -DESCRIPTION6 -EXISTING/FUTURE
POWER DEVICE 1 -TAG CB -CIRCUIT REFER MCP -MOTOR CIRCUIT 24VDC -1P DP -DISTRIBUTION E -EXISTINGPRIMARY FUNCTION 2 -LOOP NUMBER BREAKER PROTECTOR 24VDC -2P PANEL NO. F -FUTUREOPERATOR 3 -FUNCTION FU -FUSE SS -SOLID STATE 24VAC -1P LCP -LOCAL CONTROLINACCESSIBLE 4 -VOLTAGE-POLE CIRCUIT BREAKER 48VDC -2P PANEL NO. 5 -LOCATION TM -THERMAL MAGNETIC 120VAC -1P LP -LIGHTING PANEL NO.6 -EXISTING/FUTURE CIRCUIT BREAKER 208VAC -2P MCC -MOTOR CONTROL 208VAC -3P CENTER NO.240VAC -2P PCM -PROCESS CONTROL240VAC -3P MODULE NO.480VAC -3P PP -POWER PANEL NO.2400VAC -3P VCP -VENDOR CONTROL4160VAC -3P PANEL NO. 1 2
1 2
345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 3485
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 345
6 1
2 3
4 5
67 3
1 2 3 2 51 2 31 2 31 2 3 2 5
333
4 1 3 5 6 7111 31 3
33 33333333
5 6 7
6 76 76 76 76 76 7
1-2
3 4
5 6
1 2
345
6 7
1 2
3485
6 7
PlotDate:12-JUL-202311:50:35AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
00GN01
135
INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 1
8660F10 8660F1000GN01.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
TO PROCESS
INSTRUMENT OR CONNECTION
(GUIDED)
ELECTROMAGNETIC OR SONIC SIGNAL
(NOT GUIDED)
ELECTROMAGNETIC OR SONIC SIGNAL
(SOFTWARE OR DATA LINK)
INTERNAL SYSTEM LINK
PNEUMATIC SIGNAL
ELECTRIC SIGNAL
HYDRAULIC SIGNAL
CAPILLARY TUBE
IN PIPE
PRIMARY PROCESS FLOW
IN PIPE
SECONDARY PROCESS FLOW
IN CHANNEL
PRIMARY PROCESS FLOW
IN CHANNEL
SECONDARY PROCESS FLOW
EQUIPMENT ENCLOSUREEXISTING
DESIGNATIONS
MISCELLANEOUS P&ID SYMBOLS
PIPE CALLOUTPROCESS CONTINUATION
INSTRUMENT TAG IDENTIFICATION LETTERS P&ID LINE SYMBOLS
PROCESS LINE SYMBOLS
FUTURE
SIGNAL CONTINUATION
TYP
*
SCHEMATIC DETAIL
TYPICAL DETAIL
FUTURE
CONTINUATION
SHEET
UNIQUE
IDENTIFIER
CONTINUATION
SHEET
UNIQUE
IDENTIFIER
I/O TYPE DESIGNATIONS INSTRUMENT TYPE DESIGNATIONS SPECIFIC ABBREVIATIONS AUX1 RUNNING MSL MOTOR START LOW CGD COMBUSTIBLE GAS DETECTOR RTD RESISTANCE TEMP DETECTOR HTR HEATERAUX2 FAILED/FAULT MSM VALVE MODULATE COND CONDUCTIVITY SB SLUDGE BLANKET HTU HEAT TRACE UNIT AUXF1 RUNNING FORWARD MSP MOTOR STOP DO DISSOLVED OXYGEN SC STREAMING CURRENT MWH MOTOR WINDING HEATER AUXH1 RUNNING HIGH MSR MOTOR START REVERSE FMCW FREQ. MODULATED CONT. WAVE SD SLUDGE DEPTH SV SOLENOID VALVE AUXL1 RUNNING LOW MST MOTOR START IS INTRINSIC SAFETY BARRIER SH SODIUM HYPOCHLORITE SPD SURGE PROTECTIVE DEVICE AUXR1 RUNNING REVERSE SS SPEED SIGNAL LEL LOWER EXPLOSIVE LIMIT SO2 SULFUR DIOXIDE UPS UNINTERRUPTIBLE POWER SUPPLY
SVC SOLENOID VALVE CLOSE ZC POSITION COMMAND MLSS MIXED LIQUOR SUSPENDED SOLIDS TDR TIME DOMAIN REFLECTOMETRY YA STATUS AUTO
SVO SOLENOID VALVE OPEN ZCC POSITION COMMAND CLOSE ORP OXIDATION REDUCTION POTENTIAL TOC TOTAL ORGANIC CARBON YR STATUS REMOTE MS RUN ZCO POSITION COMMAND OPEN P-SUB PRESSURE SUBMERSIBLE TSS TOTAL SUSPENDED SOLIDS Y1 STATE RUNNING MSF MOTOR START FORWARD PC PARTICLE COUNTER UVI UV INTENSITY Y2 ALARM FAILED/FAULT
MSH MOTOR START HIGH PTOF PULSE TIME OF FLIGHT UVT UV TRANSMITTANCE
OPERATOR PILOT DEVICE LEGEND
PILOT DEVICE FUNCTIONDEVICE TYPE
LOCAL-OFF-REMOTE(LOR)OR
LOCAL-STOP-REMOTE(LSR)
STOP(SP)
START(ST)
HAND-OFF-AUTO(HOA)
OFF-ON(OO)
SELECT(SEL)
OPEN-STOP-CLOSE(OSC)
JOGOPEN-HOLD-CLOSE(JOHC)
SEMIAUTO-AUTO-MANUAL(SAAM)
LEAD-LAG-STANDBY(LLGS)
JOGOPEN-JOGCLOSE(JOJC)
ONLINE-OFFLINE(OLOF)
AUTO-MANUAL(AM)
FIXEDRATE-LEVELRATE(FRLR)
OPEN-CLOSE(OC)
NOOFFLINE-OFFLINE
TRANSITION(NOOT)
LOW-HIGH(LH)
RESET(RST)
SPEED(SPD)
START-STOP(STSP)
E-STOP(E-SP)
BYPASS(BYP)
SILENCE
POSITION(POS)
PILOT DEVICE TAG (HAND SWITCHES) HSA* HSB HSC HSD* HSE HSF HSG HSH HIS HSJ* HSK HSL* HSM* HSN HSO HSP HSQ* HSR HSS HST* HSU HSV HSW HSX HSY HSZ PLC I/O TAG: * = R (REMOTE), A (AUTO), ETC. INSTRUMENT FUNCTIONMEASURED VARIABLE
ELEMENT
TRANSMITTER
INDICATINGTRANSMITTER
CONVERTERTRANSDUCER,
RELAYSPECIALDEVICES
INDICATOR
RECORDER
CONTROLLER
INDICATINGCONTROLLER
RECORDINGCONTROLLER
SWITCH
SWITCH
LOWLOW
SWITCH
LOW
SWITCH
HIGH
SWITCH
HIGHHIGH
SWITCHCOMBINATION
HIGHLOW
ACTION
ALARM
LOWLOW
ALARM
LOW
ALARM
HIGH
ALARM
HIGHHIGH
TOTALIZEINDICATOR
TRANSMITTER
VALVE GAUGE LIGHT
SPEEDSETTING
A ANALYSIS AE AT AIT AY AI AR AC AIC ARC AS ASLL ASL ASH ASHH ASHL AALL AAL AAH AAHH ALB BURNER FLAME BE BT BIT BY BI BR BC BIC BRC BS BSLL BSL BSH BSHH BALL BAL BAH BAHH BL
C CONDUCTIVITY CE CT CIT CY CI CR CC CIC CRC CS CSLL CSL CSH CSHH CSHL CALL CAL CAH CAHH CLD DENSITY DE DT DIT DY DI DR DC DIC DRC DS DSLL DSL DSH DSHH DSHL DALL DAL DAH DAHH DL
E VOLTAGE ESL
F FLOW FE FT FIT FY FI FR FC FIC FRC FS FSLL FSL FSH FSHH FSHL FALL FAL FAH FAHH FQI FCV FG FL
FF FLOW RATIO FFY FFI FFC FFIC FFS FFL
H HAND (MANUAL)* HC HS* HA* HV HL HSS
I CURRENT IT IIT lY II IR IC llC IRC IS ISLL ISL ISH ISHH IALL IAL IAH IAHH lL
J POWER
K TIME KY KI KR KC KIC KRC KS KSLL KSL KSH KSHH KALL KAL KAH KAHH KV KL
L LEVEL LE LT LIT LY LI LR LC LIC LRC LS LSLL LSL LSH LSHH LSHL LALL LAL LAH LAHH LCV LG LL
M MOISTURE OR HUMIDITY ME MT MIT MY MI MR MC MIC MRC MS MSLL MSL MSH MSHH MALL MAL MAH MAHH ML
N USER'S CHOICE
P PRESSURE OR VACUUM PE PT PIT PY PI PR PC PIC PRC PS PSLL PSL PSH PSHH PSHL PALL PAL PAH PAHH PCV PL
PD DIFFERENTIAL PRESSURE PDT PDIT PDY PDI PDR PDC PDIC PDRC PDS PDSLL PDSL PDSH PDSHH PDALL PDAL PDAH PDAHH PDCV PDL
Q QUANTITY QE QT QIT QY QI QR QS QSLL QSL QSH QSHH QALL QAL QAH QAHH
R RADIATION
S SPEED SE ST SIT SY SI SR SC SIC SRC SS SSLL SSL SSH SSHH SALL SAL SAH SAHH
T TEMPERATURE TE TT TIT TY TI TR TC TIC TRC TS TSLL TSL TSH TSHH TSHL TALL TAL TAH TAHH TCV TL
TD DIFFERENTIAL TEMPERATURE TDT TDIT TDY TDI TDR TDC TDIC TDRC TDS TDSLL TDSL TDSH TDSHH TDALL TDAL TDAH TDAHH TDCV TDL
U MULTIVARIABLE UI UR UC UIC URC US UL
V VISCOSITY VE VT VIT VY VI VR VC VIC VRC VS VSLL VSL VSH VSHH VALL VAL VAH VAHH VL
W WEIGHT WE WT WIT WY WI WR WS WSLL WSL WSH WSHH WALL WAL WAH WAHH
X UNCLASSIFIED XE XT XIT XY XI XR XC XIC XRC XS XSLL XSL XSH XSHH XALL XAL XAH XAHH XCV XG XL
XV VIBRATION XVE XVT XVY XVI XVR XVS XVSH XVSHH XVAH XVAHH XVL Y STATUS*** YI YL
Z POSITION ZE ZT ZIT ZY ZI ZS** ZV ZL**
* REFER TO OPERATOR PILOT DEVICE LEGEND
** LETTER INDICATES POSITION (O=OPEN, C=CLOSED, R=RAISE, L=LOWER, ETC)
PIPE SIZE
TYPNUMTYPNUM2TYPNUM3TYPNUM4TYPNUM5TYPNUM6
?- # DWG NO.
DESC1_DESC2_
# DWG NO.
DESC1_DESC2_
PlotDate:12-JUL-202311:50:02AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
00GN02
136
INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 2
8660F10 8660F1000GN02.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
ACTUATORS
O
C
BALL
DOUBLE FLAP
FLAPPER
SWING
CHECK VALVES PRESSURE VALVES
REGULATING
PRESSURE RELIEF
VACUUM RELIEF
S
VALVES
AIR-RELIEFANGLE
BALLBUTTERFLY
CONE
DIAPHRAGM
3-WAY PLUG
4-WAY
3-WAY
BALL V-NOTCH
GATEGLOBE
HOSE
MUD
NEEDLE
PINCHPLUG ECCENTRIC
PLUG CONCENTRIC
TELESCOPING
PUMP DISCHARGE
S
P
S
P
S
DIAPHRAGMPNEUMATIC
HANDHYDRAULIC
SS
SS
S
P
S
P
~
IY
I/P
PIPING
AIR GAP
BLIND FLANGE
DRAIN
PUMPS
AIR DRIVEN
CENTRIFUGAL
DIAPHRAGM
GEAR
PISTON
SUBMERSIBLE
WATER CHAMP
FAN
BASKET STRAINER
COALESCER
EDUCTOR/EJECTOR
VAPORIZER
BLOW-OFF SILENCER
INLINE DUCT DAMPER
GAS CANNON
GRINDER
HEAT EXCHANGERHORIZONTAL MIXER
FILTERFILTER SEPARATORFLAME ARRESTER
EYEWASH
FINE FILTER
FLOW CONDITIONER
HOSE CONNECTION
INLET STRAINER
MIXER
MOTOR
NOZZLE
RUPTURE DISK
SAMPLE PORT
SIGHT TUBE
VAPOR HEATER
OR
MISC
VALVE DESIGNATIONS
NO NORMALLY OPENNC NORMALLY CLOSED
FO FAIL OPENFC FAIL CLOSEFLP FAIL LAST POSITION
SMOKE DETECTOR
FIRE ALARM/SENSOR
HOIST
EXHAUST FAN
SOLENOID
DISCRETE
ELECTRIC
MODULATING
ELECTRIC
HYDRAULIC
ELECTRIC
MODULATING
HYDRAULIC
OPEN/CLOSE
SINGLE SOLENOID
PNEUMATIC
w/ SPEED CONTROL
SINGLE SOLENOID
PNEUMATIC
OPEN/CLOSE
DUAL SOLENOIDPNEUMATIC
OPEN/HOLD/CLOSE
DUAL SOLENOIDPNEUMATIC
w/ SPEED CONTROL
OPEN/CLOSE
DUAL SOLENOIDPNEUMATIC
MODULATING
PNEUMATIC
w/ SPEED CONTROL
OPEN/CLOSE
MODULATING
PNEUMATIC
PLUGGED
CAPPED OR
INCREASER
CONCENTRIC
REDUCER
CONCENTRIC
INCREASER
ECCENTRIC
REDUCER
ECCENTRIC
COUPLING
EXPANSION
CENTER
VIBRATION
EXPANSION JOINT
CONNECTION
FLEXIBLE
DISCONNECT
QUICK
OR HOSE
PERISTALTIC
CAVITY
PROGRESSIVE
TURBINE
VERTICAL
CHOPPER
VERTICAL
BLOWER
SINGLE STAGE
CENTRIFUGAL
BLOWER
MULTI STAGE
CENTRIFUGALCOMPRESSOR
RECIPROCATING
COMPRESSOR
SCREW
COMPRESSOR
LIQUID RINGBLOWER
ROTARY LOBE
DRYERDESICCANT
COLUMNCALIBRATION
-BURIED VALVE BOX
PLUG CONCENTRIC
LUBRICATED
PLUG CONCENTRIC
BOXBURIED VALVELUBRICATED
PLUG CONCENTRIC
w-VALVE BOX
PLUG ECCENTRIC
LUBRICATED
PLUG ECCENTRIC
VALVE BOX
LUBRICATED BURIED
PLUG ECCENTRIC
BURIED VALVE BOXBUTTERFLYPRESSURE TAP
EXTERNAL
REDUCING
PRESSURE
SELF CONTAINED
REDUCING
PRESSURE
EXTERNAL TAP
REGULATING
BACKPRESSURE
SELF CONTAINED
REGULATING
BACKPRESSURE
SWINGSPRING LOADED
GENERAL
SPRING LOADED
CHECK
DIAPHRAGM
INLINE STATIC MIXER
MATERIAL CHANGE
COMPRESSORS
BLOWERS/
VALVE
OPERATED
w/THERMALLY
FLAME ARRESTER
SAMPLER
COMPOSITE
PERISTALTIC
RESTRICTION
ORIFICE
DAMPENERPULSATIONDRYER
REFRIGERATED
CLEANED
MECHANICALLY
STRAINER -
WITH BLOW OFF
STRAINER
WYE TYPE
STRAINER
ATMOSPHERE
VENT TO
UNION
TEE
PPP
DIAPHRAGM
CHEMICAL FEED
OR
VENT
PREVENTER
BACK FLOW
VALVE BOX
GATE-BURIED
DIFFUSER
AIR / CHEMICAL
LOCATOR
EQUIPMENT/INSTRUMENT
E
D
E
M
E
H
H
PS
M
LOUVER OR DAMPER
FLOAT
CONNECTION
FLANGED
PROJECT NO. FILE NAME:
DB
AAW
BAL
00GN03
137
INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 3
8660F10 8660F1000GN03.dwg
jwicks
IDENTIFIER
UNIQUE
IDENTIFIER
UNIQUE
SHEET
CONTINUATION
SHEET
CONTINUATION
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
ORIFICE
DISPLACEMENTPOSITIVEVORTEX
V-CONE
THERMAL
BATCH
CORIOLIS
MAGNETIC
PADDLE WHEEL
ROTAMETER
BUBBLER
CAPACITANCE
ELECTRODE
FLOAT
INVERTED COLUMN
RADAR PTOFRADAR TDR
ULTRASONIC
GAUGE
PRESSURE SWITCH
KNIFE
SLIDESLUICESTOP
SLIDESLUICESTOP
FLAP
WEIR
PARSHALL
LEOPOLD-LAGCO
PALMER-BOWLUS
TRAPEZOIDAL
CUTTHROAT
REGULAR
w/ END CONTRACTIONS
RECTANGULAR
TURBINE
PROPELLEROR FLOW NOZZLE
VENTURI TUBE
PRESSUREDIFFERENTIAL
SUBMERSIBLESUSPENDED/
ANNULAR
SEAL
DIAPHRAGM
SEAL
SANITARYSEAL
PRESSURE SWITCH
MANOMETER
PRESSURE DIFFERENTIAL PRESSURE PRESSURE SEALS
INDICATOR
DIFFERENTIAL
GAUGE
TRANSMITTER
PRESSURE
SWITCH
PRESSUREDIFFERENTIAL
TRANSMITTER
PRESSUREDIFFERENTIAL
TUNING FORK
PISTON
WEIRS
SIDE VIEW PLAN VIEW
FLOW FLUMES LEVEL
SIDE VIEW PLAN VIEW
w/o END CONTRACTIONS
RECTANGULAR
w/o END CONTRACTIONS
RECTANGULAR
w/ END CONTRACTIONS
RECTANGULAR
(TRIANGULAR)
V-NOTCH
(TRIANGULAR)
V-NOTCH
(CIPOLLETTI)
TRAPEZOIDAL
(CIPOLLETTI)
TRAPEZOIDAL
PRESSURE/VACUUM
EXAMPLE
GATES
PITOT TUBE
ANNUBAR
ULTRASONIC
BIOGAS
ULTRASONIC
THERMOMETER
HYDRAULIC
STRAIN GAUGE
w/THERMOWELL
TEMPERATURE
GAUGE
TEMPERATURE
WEIGHT
TEMPERATURE
PROBE
CONTINUOUS WAVE)
MODULATED
(FREQUENCY
RADAR
BUTTERFLY
MM
K
N
A
T
T
NETWORKS
OPTIC CABLE
24-STRAND FIBER
REPRESENTS ONE
FIBER LINE
24/FO-SM
OPTIC CABLES
24-STRAND FIBER
REPRESENTS TWO
FIBER LINE
(2) 24/FO-SM (1) 24/FO-SM EA.
OPTIC CABLE
24-STRAND FIBER
REPRESENTS ONE
EACH FIBER LINE
FIBER ABBREVIATIONS
XX = MODEFO = FIBER OPTIC## = STRAND COUNT
##/FO-XX
MM = MULTIMODE
SM = SINGLE MODE
(4)
CABLES
COPPER ETHERNET
REPRESENTS FOUR
COPPER LINE
(2) EA.
CABLES
COPPER ETHERNET
REPRESENTS TWO
EACH COPPER LINE
NETWORK ABBREVIATIONS
VLAN SYMBOLS
= BUSINESS NETWORK= SECURITY CONTROL NETWORK= BUILDING MANAGEMENT SYSTEM= PROCESS CONTROL NETWORK
MISCELLANEOUS NETWORK SYMBOLS
NETWORK CABLE CONTINUATIONS
CONTINUATION
TOP OF PAGE STYLE
FIELD NETWORK DEVICE
NETWORK EQUIPMENT CALLOUT
TAG
DESC 1
CABLE CALLOUTS AND ABBREVIATIONS
FPP
ES
NPNR
PCN-W
SCN
PLCNPCN
MIN
FCN
BSNBMS
= FIBER PATCH PANEL= ETHERNET SWITCH= NETWORK PANEL= NETWORK RACK= WIRELESS PROCESS CONTROL NETWORK= SECURITY CONTROL NETWORK= PLC NETWORK= PROCESS CONTROL NETWORK= MAINTENANCE INFORMATION NETWORK= FIELD CONTROL NETWORK= BUSINESS NETWORK= BUILDING MANAGEMENT SYSTEM
COPPER ETHERNET
FIBER OPTIC ETHERNET
WIRELESS ETHERNET
PROFIBUS DPPROFIBUS PA
NETWORK LINE SYMBOLS
STYLE CONTINUATION
BOTTOM/LEFT OF PAGE
SYMBOL
DEVICE SPECIFIC
= WIRELESS PROCESS CONTROL NETWORK= MAINTENANCE INFORMATION NETWORK= PLC NETWORK= FIELD CONTROL NETWORK
SERIAL DATA
PDIT
PDSL
PSH
PSH
PIT
PEPE
PDEPDE
PE
PI PDI
SEGMENT #
P&ID DRAWING REFERENCE
DESC 3
DESC 2
DESC 1
TAG
PROTOCOL
PANEL TAGPLC TAG
#
DWG NO.
DESC 1
DESC 2
DESC 3
#
DWG NO.
DESC 1
DESC 2
DESC 3
GATE
WASTE
PlotDate:12-JUL-202311:51:12AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
00GN04
138
INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 4
8660F10 8660F1000GN04.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PROCESS SWITCHES HAND SWITCHES RELAYS TERMINAL BLOCKS I/O MISC
CLOSE ON RISING LEVEL
FLOAT SWITCH
OPEN ON RISING LEVEL
FLOAT SWITCH
CLOSE ON RISING PRESSURE
PRESSURE SWITCH
OPEN ON RISING PRESSURE
PRESSURE SWITCH
CLOSE ON RISING TEMPERATURE
TEMPERATURE SWITCH
OPEN ON RISING TEMPERATURE
TEMPERATURE SWITCH
CLOSE ON INCREASE IN FLOW
FLOW SWITCH
OPEN ON INCREASE IN FLOW
FLOW SWITCH
OPEN ON RISING VIBRATION
VIBRATION SWITCH
CLOSE ON RISING VIBRATION
VIBRATION SWITCH
OPEN ON HIGH TORQUE
TORQUE SWITCH
THREE POSITION SELECTOR SWITCH TWO POSITION SELECTOR SWITCH
MUSHROOM HEAD PUSHBUTTONMAINTAINED CONTACT
PUSH-PULL PUSHBUTTONPULL CORD SWITCH
IN PLC/PCM PANEL
TERMINAL
IN MOTOR CONTROL CENTER
TERMINAL
IN LOCAL STARTER CONTROL PANEL
TERMINAL
AT FIELD DEVICE
TERMINAL
IN FIELD PANEL
TERMINAL
IN (USER CHOICE)
TERMINAL
DIGITAL BUS CONNECTOR
a = INPUT OR OUTPUT AS INDICATED
PLC DISCRETEDIGITAL BUS
SOLENOID
M = TYPEMETER UNIT MOTOR
CIRCUIT BREAKER
DISCONNECT
FUSE
* - MOTOR TAG I.D.
MOTOR WINDING HEATER
VARISTOR
CAPACITOR
RESISTOR
BATTERY
DIODE
OVERLOAD CONTACT
DRAWOUT CONNECTION
GROUND
LIGHTNING ARRESTOR
a = INPUT OR OUTPUT AS INDICATED
PLC ANALOG
IN RTU
TERMINAL
STOP-LOCKOUT PUSHBUTTON
SPRING-RETURN
SPACE HEATER
ELAPSED TIME METER
PADLOCK SWITCH
xox
xoxoo
ANALOG
a
DIGITAL
BUS
a
M
MWH-*
KI-*
ETM
HP
a
bc
d
H1 H3 H2 H4
X1 X2
xoo
CLOSE ON HIGH TORQUE
TORQUE SWITCH
NCTCNCTONOTCNOTO
CONTROL CONTACT
NORMALLY CLOSED
CONTROL CONTACT
NORMALLY OPEN
TIMED CLOSING
NORMALLY OPEN
TIME DELAY CONTACTTIMED OPENING
NORMALLY CLOSED
TIME DELAY CONTACTTIMED OPENING
NORMALLY OPEN
TIME DELAY CONTACTTIMED CLOSING
NORMALLY CLOSED
TIME DELAY CONTACT
LIMIT SWITCH
NORMALLY CLOSED
HELD OPEN LIMIT SWITCH
NORMALLY CLOSED
LIMIT SWITCH
NORMALLY OPEN
HELD CLOSED LIMIT SWITCH
NORMALLY OPEN
MOMENTARY PUSHBUTTON
NORMALLY OPEN
MOMENTARY PUSHBUTTON
NORMALLY CLOSED
TRANSFORMER
CONTROL POWER
HEATERS
MOTOR OVERLOAD
PROTECTION
TRANSIENT SURGE
CLOSED IN
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
CLOSED IN
CLOSED IN
CLOSED IN
d = DESCRIPTION
c = TIMING RANGE/SETTING
TDOFF - TIME DELAY ON DEENERGIZATION
b = TDON - TIME DELAY ON ENERGIZATION
R -MOTOR STARTER COIL - REVERSEF -MOTOR STARTER COIL - FORWARDH -MOTOR STARTER COIL - HIGH SPEEDL -MOTOR STARTER COIL - LOW SPEEDM -MOTOR STARTER COILTD -TIME DELAY RELAYCR -CONTROL RELAY a = TYPE
RELAY COIL
* = E -ETHERNET* = H2 -FOUNDATION FIELDBUS H2* = H1 -FOUNDATION FIELDBUS H1* = DP -PROFIBUS DP* = PA -PROFIBUS PA* = D -DEVICENET
INDICATORS
HORN
C = CLEARM = MAGENTAB = BLUEA = AMBERW = WHITEG = GREENR = RED a = LENS COLOR
BEACON
C = CLEARY = YELLOWB = BLUEA = AMBERW = WHITEG = GREENR = RED a = LENS COLOR
a PILOT LIGHTa
a
H
*
PlotDate:12-JUL-202311:46:14AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
AAW
INSTRUMENTATION
SCHEMATIC SYMBOLS
8660F10 8660F1000GN05.dgn
BAL
00GN05
139
awills
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
TERMINAL PANEL
PCM-300
PLC
MCC-1201
VFD
REMOTE
REMOTE
STOP
START
REMOTE
AUX1-210
RUNNING
FAIL
AUX2-210
WINDINGMOTORMWH-210HEATERMOTORCONNECTION
J-BOX
J-BOX
MWH
210
PMP
210
TSH
210
PSH
210
PE
210
M
J-BOX
SPEED INLOCALHSAL-210LOCALMODE
FIT
210
FE
210
FQT
210
OFF
LOCAL REMOTE
xoo
oox
STOPLOCALHSB-210
STOP
HSC-210LOCALSTART
LCP-210
PMP-210UTILITY WATER PUMPMOTOR:
INV. DUTY, TEFCTOSHIBA MODEL: XYZ
PUMP
200 GPM @ 20 FT TDH
900-1800 RPM
GOULD MODEL: XYZ
MODEL: XYZRANGE: 0-200 PSIGSETPOINT: 50 PSIGENDRESS HAUSERCAT NO.: XYZFLOW RANGE: 200-2500 GPMFLOW TOTAL: 1 PULSE/500 GAL (PSH210-1/PCM300-CB1300H2)
(PSH210-2/PCM300-C0001)
AQ0001+
AQ0001-
SHLD
FU1300-P1
FU1300-M1
<BLK-1><WHT-1>
FU1300-H1
I001
<BLK>
Q001A
<BLK>
Q001B
<RED>
E-STOP
Q002A
<BLU>
C0001
Q002B
CB1-210HCB1-210N
120VAC
FU1300-P2
FU1300-M2
FU1300-P3
<BLK-1><WHT-1><BLK-2><WHT-2>
C0004
FU1300-H3
I003
<BLU>
I004
FU1300-H4
<ORG>
FU1300-H5
I006
<YEL>
(VFD210-11,12/PCM300-AQ001)
(VFD210-13,14/PCM300-AI001)
(VFD210-15/PCM300-Q001A)(VFD210-16/PCM300-Q001B)(VFD210-17/PCM300-Q002A)(VFD210-18/PCM300-Q002B) (FIT210-L/PCM300-CB1210H)
(FIT210-N/PCM300-CB1210N)
(FIT210-1,2/PCM300-AI002)
(FQT210-4,5/PCM300-FU1300P3; C0004)
(VFD210-20/PCM300-I003)(VFD210-22/PCM300-I004)
(LCP210-3/PCM300-FU1300H5)
(LCP210-4/PCM300-I006)
(MWH210-H/VFD210-33)
(MWH210-C/VFD210-X2)
(PMP210-T1/VFD210-T1)(PMP210-T2/VFD210-T2)(PMP210-T3/VFD210-T3) (TSH210-NC/PCM300-CB1300H1)
(TSH210-C/PCM300-I001)
(LCP210-P1/VFD210-1)
(LCP210-P2/VFD210-2)(LCP210-P3/VFD210-3)
(LCP210-1/VFD210-5)(LCP210-2/VFD210-6)(LCP210-5/VFD210-7)(LCP210-6/VFD210-8)(LCP210-7/VFD210-9) (LCP210-8/VFD210-10)
HSS
210
HSA
210
HSB
210
HSC
210
FE/FIT/FQT-210PE/PSH-210
START
(CB1300-H)
AI001+
SHLD
FU1300-H2
C0002C0003
(VFD210-24/PCM300-C0003)(VFD210-23/PCM300-C0002)
(VFD210-19/PCM300-FU13000H3)
(VFD210-21/PCM300-FU1300H4)
SHLD
AI002+
120 VAC
MODEL: XYZ
PHOENIX
GND
SHLD
(C0002)(C0003)(C0001)(CB1300-H6) (I005)(C0004)(FU1300-M3)(CB1300-H7) (I002) (PSH210-1/PCM300-C001)
(PSH210-1/PCM300-FU1300H2)
(TSH210-NC/PCM300-I001)
(TSH210-NC/PCM300-FU1300H1)
(FU1300-P)
MM
(CB1-300N1)
1 2
3 4
5 67
8 210
%AQ001SPEED OUTRACK 1SLOT 2
12 210
%AI001SPEED INRACK 1SLOT 3
TSH
210
%I001MTR TEMPRACK 1SLOT 4
MSP
210
%Q001STOPRACK 1SLOT 5
PSH
210
%I005HI PRESSRACK 1SLOT 4
F
210
%AI002FLOWRACK 1SLOT 2
FQ
210
%I002FLOW TOTRACK 1SLOT 4
AUX1
210
%I003RUNNINGRACK 1SLOT 4
AUX2
210
%I004FAILRACK 1SLOT 4
HSAR
210
%I006REMOTERACK 1SLOT 4
210
%Q002STARTRACK 1SLOT 5
834
1112
7564334
10 9121122
315 6
2442
5 613
2324222119201817151614131211
T3T1T2
X2
33 9
10 87654213
CR1
210
CR2
210
120 VAC
MODEL: XYZ
PHOENIX
UTILITY WATER HIGH PRESSUREUTILITY WATER FLOW METER
120 VAC
24 VDC
CB1-300H
FU1-300P
+- FU1-300M
CB1-300N (CB1300-N)
SS-210SB-210
SSSB
OUT
SPEED
IN
SPEED
VFD-210
SECTION - 3
CUBICLE - 2
30HP, 480VAC, 42 AMPS
CONSTRUCTION. THE LOOP DIAGRAM SHOWN ABOVE DISPLAYS THE LEVEL OF EXPECTED DETAIL.
DIAGRAMS FOR THE ENTIRE FACILITY. PRELIMINARY DETAILED LOOP DIAGRAMS TO BE SUBMITTED FOR REVIEW PRIOR TO BEGINNING THE ABOVE DRAWING IS INCLUDED AS AN EXAMPLE ONLY AND IS NOT PROJECT SPECIFIC. CONTRACTOR SHALL FURNISH LOOP C-01-002
S-01-001
S-01-003
L-01-001
C-01-001
C-01-003
P-01-001 P-01-002
S-01-002
P1
P2
P3
MSP-210
MS-210 MS
H
CC
1 2
L
N
G
1 2
4 5
T1
T2
T3
NC
PlotDate:12-JUL-202311:46:07AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
AAW
INSTRUMENTATION
SAMPLE LOOP DRAWING
8660F10 8660F1000GN06.dgn
BAL
00GN06
140
awills
1 /4"
6 1/4"
2"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
XXX AMPS, XXX VOLTS, 1Ø
CP-99400
PLC-99400
XXX AMPS, XXX VOLTS, 1Ø
CP-99400
PLC-99400
11 0 31 0
90 70 50
30°F
Pfannenberg
2 1
NL
TEST MONTHLY
SEE INSTRUCTIONS
RESETR
ESET
TESTTE
ST
NO
NC
COM
/G N L L N /G
QUINT POWER
AC100-240V
L
Input N
22.5-28.5V
DCOK
Adjust
OutputDC24V5A
13 OK
14 DC
QUINT POWER
AC100-240V
L
Input N
22.5-28.5V
DCOK
Adjust
OutputDC24V5A
13 OK
14 DC
86 LNK
ACT
LNK
ACT
42 LNK
ACT
LNK
ACT
7 5
31 LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
!
LNK/ACTLNK/ACT
X
2 F
X
1 F
LNK
GB1 ACT GB2
11 0 31 0
90 70 50
30°F
Pfannenberg
2 1
PlotDate:12-JUL-202311:46:26AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
AAW
INSTRUMENTATION
8660F10 8660F1002N001.dgn
SCALE:FILE:
1- NAMEPLATE DETAIL 6' = 1'-0"
1- 3 19 13
21 18
17 5
6 4
2 1
7 8
POWER ON
SCALE:FILE:
2- 6' = 1'-0"
2- 22
15 16
15 12
CP-99400 PANEL ELEVATION EXTERIOR
8660F1000N671.2dm8660F1000N671.2dm
8 8 8 8
8 8
11 20
23 8
PCM-99400 PANEL ELEVATION INTERIOR
25 28
26 GENERAL NOTES:
PCM-99400 ELEVATION LAYOUT
02N01
9 14
CABINET.
7. QUANTITY OF COMPONENTS VARY AS REQUIRED FOR EACH
PENETRATIONS ALLOWED.BOTTOM OF THE ENCLOSURE. NO SIDE, FRONT, OR REAR
6. ALL CONDUIT PENETRATIONS SHALL BE LOCATED AT THE TOP OR CONTROL CABINETS.
5. NO 480VAC CIRCUITS SHALL TERMINATE IN OR PASS THROUGH SHORT CIRCUIT RATINGS.
4. FOLLOW ALL UL 508 AND 508 SUPPLEMENT 5B TO DETERMINE THE NATIONAL ELECTRIC CODE.
3. CONSTRUCT PANEL TO MEET THE FULL INTENT OF ARTICLE 409 OF 2. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.
NUMBERS.LAYOUT WITH ALL EQUIPMENT, MANUFACTURERS, AND PART TO SUPPLY AS-BUILT DRAWINGS SHOWING FINAL ENCLOSURE
1. ENCLOSURE DRAWING REPRESENTS DESIGN INTENT. CONTRACTOR BAL
lbordelon
27 PILOT DEVICES DETAIL
CONTROL PANEL - BILL OF MATERIALS
ITEM DESCRIPTION
1 ENCLOSURE
2 NAMEPLATE
3 DATA POCKET
4 INTRUSION DOOR SWITCH
5 INTERNAL FOLDING SHELF
6 CABINET LIGHT WITH DOOR SWITCH7 POWER PILOT LIGHT
8 WIRE DUCT (AS REQUIRED)9 DIN RAIL (AS REQUIRED)
10 NOT USED
11 PLC CHASSIS
12 MANAGED ETHERNET SWITCH
13 ANALOG TERMINAL BLOCKS (AS REQUIRED)
14 RECEPTACLE
15 POWER SUPPLY, 24VDC (2 EA.)
16 REDUNDANCY MODULE17 24VDC POWER DISTRIBUTION TERMINALS 18 120VAC SURGE PROTECTOR19 CP POWER DISTRIBUTION
20 DISCRETE TERMINAL BLOCKS
21 GROUND BAR
22 TEMPERATURE SWITCH
23 CONTROL RELAYS
24 NOT USED
25 LOCAL OPERATOR INTERFACE (LOI)
26 ELECTRONIC CIRCUIT PROTECTOR27 COOLING FAN
28 EXHAUST GRILLE
141
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PlotDate:12-JUL-202311:47:29AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
LMB
INSTRUMENTATION
8660F10 8660F1002N002.dgn
02N02
lbordelon
BAL
PCM-4 PANEL MODIFICATIONS
2 1
3 4
6 5
3 PCM-4 PANEL ELEVATION INTERIOR PCM-4 PANEL ELEVATION EXTERIOR EXISTING PLC-3 PANEL ELEVATION INTERIOR (NOT SHOWING THE COMPLETE INTERIOR)
# KEY NOTES:
7 8 9
9 REMOVED PER KEY NOTE 5.THE SAME FUNCTIONALITY AS WAS PRESENT INCLUDING THE ITEMS NEW PLC. ADDITIONALLY, THE NEW PLC AND LOI SHALL PROVIDE
9. ALL EXISTING PROGRAMMING SHALL BE REPROGRAMMED IN THE SHALL BE INSTALLED ON THE PLATE SPECIFIED IN KEY NOTE 6.SPECIFIED IN CONTRACT DRAWINGS AND SPECIFICATION 17721. LOI
8. PROVIDE AND INSTALL NEW LOCAL OPERATOR INTERFACE AS
THE PANEL'S NEMA RATING.LIGHTS, SELECTOR SWITCHES, AND PUSH BUTTONS TO MAINTAIN
7. USE APPROPRIATE PLUGS TO INDIVIDUALLY COVER THE PILOT TO INSTALL THE NEW LOI.BOLT A PLATE TO COVER THE HOLE. THIS PLATE SHALL BE UTILIZED
6. CUT ONE LARGE SQUARE HOLE IN THE AREA SHOWN, GASKET AND SCADA AS NEEDED.FUNCTIONALITY SHALL BE REPLICATED ON THE NEW LOI AND PUSH BUTTONS, PILOT LIGHTS, AND SELECTOR SWITCHES CHART RECORDER, REDIPANEL KEYPAD MODULE, ANNUNCIATOR, SELECTOR SWITCHES AND RETURN TO THE OWNER. EXISTING MODULE, ANNUNCIATOR, PUSH BUTTONS, PILOT LIGHTS, AND
5. REMOVE EXISTING CHART RECORDER, REDIPANEL KEYPAD
SPECIFICATIONS.MAY BE REQUIRED PER CONTRACT DRAWINGS AND RELAYS, TERMINAL BLOCKS, FUSES AND CIRCUIT BREAKERS THAT
4. UTILIZE THE IDENTIFIED EMPTY SPACES AS NEEDED FOR ANY NEW TO THESE NEW PATCH PANELS AS SHOWN ON 04N02.FIBER PATCH PANEL LOCATED IN PLC-3 AND SHALL BE CONNECTED PLC-12199 PANELS SHALL BE DISCONNECTED FROM THE EXISTING EXISTING FIBER CONNECTIONS COMING FROM PLC-70299 AND TRACE AND FIELD VERIFY EXISTING FIBER CONNECTIONS. THE TWO SPECIFIED IN CONTRACT DRAWING AND SPECIFICATION 17733.
3. PROVIDE AND INSTALL NEW FIBER PATCH PANEL IN PLC-4 AS 04N02. NETWORK CONNECTIONS AS SHOWN ON CONTRACT DRAWING CONTRACT DRAWINGS AND SPECIFICATION 17733. CONNECT PROCESSOR WAS PREVIOUSLY INSTALLED AS SPECIFIED IN AND INSTALL ETHERNET SWITCH IN THE SPACE WHERE THE OLD
2. REMOVE PLC PROCESSOR AND RETURN TO THE OWNER. PROVIDE CONNECTED TO THE EXISTING PLC.SAME SLOT NUMBER AND IO POINT AS THEY WERE PREVIOUSLY POSSIBLE, TERMINATE EXISTING IO WIRES TO THE NEW PLC IN THE BEFORE REMOVING WIRES FROM THE EXISTING PLC. WHERE VERIFY ALL EXISTING IO WIRING AND NETWORK CONNECTIONS CONTRACT DRAWINGS AND SPECIFICATION 17720. TRACE AND FIELD OWNER. PROVIDE AND INSTALL NEW PLC AS SPECIFIED IN
1. REMOVE EXISTING PLC RACK AND MODULES AND RETURN TO THE 142
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PlotDate:12-JUL-202311:47:25AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
LMB
INSTRUMENTATION
8660F10 8660F1002N003.dgn
02N03
crollins
BAL
1 # KEY NOTES:
PLC-70299 PANEL MODIFICATIONS
22 PLC-70299 PANEL ELEVATION INTERIOR
143
TERMINAL BLOCKS, FUSES AND RELAYS.
2. UTILIZE EMPTY AREAS IF ADDITIONAL SPACE IS REQUIRED FOR NEW NEW TERMINAL BLOCKS AND FUSES AS NEEDED.HORIZONTAL SPACE CREATED BY THE SMALLER PLC CHASSIS FOR RELAYS TO TERMINATE NEW IO POINTS AS REQUIRED. UTILIZE PROVIDE AND INSTALL DIN RAIL, TERMINAL BLOCKS, FUSES AND AS SHOWN ON CONTRACT DRAWING 04N03 AND SPECIFICATION. PROVIDE AND INSTALL ETHERNET SWITCH AND FIBER PATCH PANEL
1. REMOVE EXISTING EMPTY PLC RACK AND RETURN TO THE OWNER.
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWER
STATUS
ADDRESS/ERROR
ControlNet
MODULE NET
# KEY NOTES:
5 1
2 4
3 TOP OF GENERATOR BUILDING.
7. OMNIDIRECTIONAL BASE STATION ANTENNA. TO BE INSTALLED ON PUMP STATION.
6. COMMUNICATES WITH NEW TRANSCEIVER AT RECYCLED WATER
5. COMMUNICATES WITH NEW TRANSCEIVER AT WWTP.
CONTROL PANEL.
4. INSTALL COAXIAL CABLE SURGE PROTECTION DEVICE IN THE MAST.
3. MINIMUM 10 FT. LOOP OF ANTENNA CABLE AT BASE OF ANTENNA ENDS AGAINST WEATHER.
2. 10 FT. 2" GRC MAST FOR ANTENNA MOUNTING. CAP MAST BOTH
1. HIGH-GAIN YAGI ANTENNA.
2 4
3 7
1 3
2 4
PWR
FANS
ALARM
STATUS
HA
TEMP
USB
5 7
6 8
9 11
10 12
MA1MA2
MGT
CONSOLE
CLEI
CONSOLE
NEARBY SCADA SYSTEM CABINET
SYSTEM INTERFACE LOCATED IN
DATA LINK TO EXISTING SCADA
PCM-99400
RADIO PANEL
RECYCLED WATER PUMP STATION
FW-99400
RAD1-99400
6 ANT1-99400
RAD2-99400
ANT2-99400
HMI-99400
SW-99400
PLC-99400
PQM-99400
99N001
PUMP #1
RECYCLED WATER
PMP-99411
PLC-99400 EIP
99N002
PUMP #2
RECYCLED WATER
PMP-99412
PLC-99400 EIP
99N002
PUMP #3
RECYCLED WATER
PMP-99413
PLC-99400 EIP
99N002
PUMP #4
RECYCLED WATER
PMP-99414
PLC-99400 EIP
99N003
PUMP #5
RECYCLED WATER
PMP-99415
PLC-99400 EIP
ELECTRICAL BUILDING
86 LNK
ACT
LNK
ACT
42 LNK
ACT
LNK
ACT
7 5
31 LNK
ACT
LNK
ACT
LNK
ACT
LNK
ACT
!
LNK/ACTLNK/ACT
X
2 F
X
1 F
LNK
GB1 ACT GB2
RADIO PANEL
POWER GENERATION BUILDING
WWTP
SWBD-RWPS
PlotDate:12-JUL-202311:49:18AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
04N01
144
INSTRUMENTATION
RECYCLED WATER PUMP STATION
NETWORK BLOCK DIAGRAM
8660F10 8660F1004N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PLC1-4
LOI-4
LOI
ESP-4
12/FO-MM
FPP1-4
FIBER PATCH PANEL
GENERAL NOTES:
NEEDED FOR A FULLY FUNCTIONAL SYSTEM.
4. PROVIDE ADDITIONAL HARDWARE AND CONFIGURATION AS
OTHERWISE NOTED.
3. COMMUNICATION PROTOCOL SHALL BE ETHERNET/IP, UNLESS
PATCHED THROUGH TO DEVICES AS SHOWN.
(NOT SHOWN FOR CLARITY) OR SURGE PROTECTION DEVICE AND
ENCLOSURE SHALL BE MADE THROUGH COPPER PATCH PANELS
2. ALL COPPER CONNECTIONS FROM DEVICES EXTERNAL TO THE
CONNECTIONS, UNLESS NOTED OTHERWISE.
1. PROVIDE DUPLEX PATCH CABLES FOR ALL INTERNAL FIBER
BUILDING
EQUIPMENT
DAFT
PLC70299
BUILDING
GENERATION
POWER
PLC12199
12/FO-MM
FPP2-4
FIBER PATCH PANEL
PCM-4
TREATMENT BUILDINGADVANCED WASTEWATER
VCP-3
WORKSTATION
EXISTING HMI
VENDOR CONTROL PANEL
AWT CLARIFIER/FILTER
PlotDate:12-JUL-202311:48:42AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
04N02
145
INSTRUMENTATION
ADVANCED WASTEWATER TREATMENT
NETWORK BLOCK DIAGRAM
8660F10 8660F1004N002.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
12/FO-MM
FPP1-70299
FIBER PATCH PANEL
GENERAL NOTES:
SHOWN.
1. DRAWING REFLECTS NEW SCOPE. EXISTING CONNECTIONS NOT NJB-60001
DECHLORINATION FACILITY
FPP1-60001
FIBER PATCH PANEL
ESF-70299
ETHERNET SWITCH
TO EXISTING ETHERNET
CONNECTIONS
60N001
VALVE 1
DCL STRUCTURE
FV-60100
PLC-70299 EIP
PLC-70299
DAFT BUILDING
60N001
VALVE 2
DCL STRUCTURE
FV-60102
PLC-70299 EIP
LNKACTSPD1000
10/100/1000Base-T
RX
TX
LNK ACT
1000Base-SX/LX
LNKACTSPD1000
10/100/1000Base-T
RX
TX
LNK ACT
1000Base-SX/LX
ETHERNET SWITCH
MC1-60001
MEDIA CONVERTER
MC2-60001
MEDIA CONVERTER
89N001
CAROUSEL PUMP 1
PMP-89100
PLC-70299 EIP
89N001
CAROUSEL PUMP 2
PMP-89101
PLC-70299 EIP
89N001
CAROUSEL PUMP 3
PMP-89102
PLC-70299 EIP
91N001
PAU PUMP 1
PMP-99100
PLC-70299 EIP
PlotDate:12-JUL-202311:50:52AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
CGR
BAL
04N03
146
INSTRUMENTATION
DAFT BUILDING NETWORK BLOCK DIAGRAM
8660F10 8660F1004N003.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
VFD-*
480V
MWH-*
CR1-*
SPD
H1 H3 H2 H4
X1 X2
M
VFD
RUNNING
1Ø CONTROL TRANSFORMER
480V PRI120V SEC
CR
DI REMOTE
DO
PORT
PROGRAMMING
SERIAL
ETHERNET
IP
DO
RUNNING
HSC-*
START
oox
HSA-*
OFF
LOCAL REMOTE
xoo
DI
DO DO
TSH-*
DIDIDI SPARE
GROUND
GENERAL NOTES:
POWER (L) POWER (N)
PMP-*
SPEEDHSS-*
LOCALSPEED
* = 99411 PMP - 99411
* = 99413 PMP - 99413
* = 99414 PMP - 99414
AUX3-*
POWER
FSL-*
3. REFER TO SPECIFICATION 17101 FOR CONTROL DESCRIPTIONS.
INDICATED LOADS.
2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL BASED ON THE SELECTED MANUFACTURER.THE OPERATION SHOWN HERE AND DESCRIBED IN 17100 AND 17101 MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM
1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
TAG LOOP REFERENCE DWG.
99N01
STOP
HSB-*
1 RECYCLED WATER PUMPS
99N01, 99N02
DI STOPDI START
* = 99412 PMP - 99412 99N02
99N0299N02
SPARE
MODULE (HM)
HUMAN INTERFACE
VFD KEYPAD/
COMPONENTS
SPECIFICATIONS FOR INPUT
DIAGRAMS AND
REFER TO ONE-LINE
DESIGN TOPOLOGY
AND SPECIFICATIONS FOR VFD
REFER TO ONE-LINE DIAGRAMS
OUTPUT COMPONENTS
SPECIFICATIONS FOR
DIAGRAMS AND
REFER TO ONE-LINE
HIGH TEMPERATURELOW FLOW
CR1-*
1 # KEY NOTES:
1. FLOW SWITCH SHALL BE RESET THROUGH THE PCS.
PlotDate:12-JUL-202311:46:20AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
TCD
INSTRUMENTATION
8660F10 8660F1006N001.dgn
06N01
CONTROL SCHEMATIC 1
BAL
147
crollins
120VAC
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
GENERAL NOTES:
KEY NOTES:
REQUIREMENTS.
COMPONENTS TO MEET PROJECT
ONLY. PROVIDE ALL NECESSARY
1. SCHEMATIC ILLUSTRATES DESIGN INTENT
#
RECEPTACLE
GFCI
6 120VAC SURGE PROTECTIVE DEVICE
24VDC SURGE PROTECTIVE DEVICE
H N G
8 2
2 (AS REQUIRED)
I/O POWER
(AS REQUIRED)
INSTRUMENT POWER
2 (AS REQUIRED)
PLC POWER SUPPLY
UL
ULUL
GGG
NNN
2 (WHERE APPLICABLE)
LOI
UL
G
N
L1 N
GND
+ - SUPPLY
POWER
SWITCHING
24VDC OUT
2 L1 N
GND
+ - SUPPLY
POWER
SWITCHING
IN 1 IN 2 - +
+ - 24VDC OUT
ULUL
GG
NN
+ - XA4-*
SPD2 FAIL
INPUT
SIG COM
SIG COM
JS4-*
ACB OK
INPUT
JS3-*
REDUNDANCY OK
INPUT
SIG COM
JS2-*
POWER SUPPLY OK
INPUT
SIG COM
JS1-*
POWER SUPPLY OK
INPUT
SIG COM
INPUT
XA7-*
ECP-P FAIL
INPUT
XA5-*
ES-P FAIL
INPUT
(AS REQUIRED)
SIGNAL ISOLATORS
(AS REQUIRED)
INSTRUMENT POWER
(AS REQUIRED)
PLC I/O MODULES --- +++
LINE NEUTRAL GND
5 H THERMOSTAT N
3 CONDITIONER
CABINET FAN / AIR
9 9
G
LIGHT
CABINET
9 GG
NN
HH
5A-1P
24VDC OUT
SIG COM
TSH-*
HIGH CABINET TEMP
INPUT
SWITCH
TEMPERATURE
SIG COM
ZS1-*
INTRUSION
INPUT
DOOR SWITCH
4 ECP
SIG COM
(PLC)
ETHERNET SWITCH
ES-P
SIG COM - G + - 2
TAG LOOP REFERENCE DWG.
2 5
LOCATED WITHIN PCM CABINET
CONTINUED AT UPPER RIGHT
CONTINUED AT LOWER LEFT
TERMINAL BLOCK LEGEND
PCM
HN
G
UL
+- 120VAC NEUTRAL GROUND UPS 120VAC 24VDC (+) 24VDC (-)
SPD FAIL
(AS REQUIRED)
TELEMETRY RADIO
+ - SPECIFICATIONS.
9. PROVIDE QUANTITY REQUIRED PER
PCM CABINET.
EACH INSTRUMENT POWERED FROM THE
PROVIDE SEPARATE CIRCUIT BREAKERS FOR
8. SIZE BASED ON PROTECTION NEEDS.
7. NOT USED.
LAPTOP.
SPECIFICATIONS. SIZE RECEPTACLE FOR
6. PROVIDE QUANTITY REQUIRED PER
5. SIZE BASED ON LOAD REQUIREMENT.
NON-OVERLAPPING DOORS.
SWITCHES, WIRED IN SERIES, FOR
OVERLAPPING DOORS. PROVIDE ADDITIONAL
4. INSTALL SWITCH ON OUTERMOST DOOR OF
CIRCUIT IF REQUIRED.CALCULATIONS. PROVIDE ADDITIONAL
3. VERIFY LOADS BASED ON TEMPERATURE
2. SIZE BASED ON PROTECTION NEEDS.
1. NOT USED.
XA6-*
* = 99400 PCM-99400 99N04
DISCRETE-ANALOG PCM CABINETPLC AND INSTRUMENT POWER
99N04
PlotDate:12-JUL-202311:46:38AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
TCD
INSTRUMENTATION
8660F10 8660F1006N002.dgn
06N02
CONTROL SCHEMATIC 2
BAL
148
awills
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
M PMP-*
TM
GND
480V
H1 H3 H2 H4
X1 X2
120V SEC480V PRI1PH CONTROL TRANSFORMER
120VAC
MOV
CR3-*
CR
RUNNING
VFD
3 TAG LOOP REFERENCE DWG.
CAROUSEL PUMPS
89N01
* = 89100 PMP-89100
* = 89101 PMP-89101 89N01
89N01
* = 89102 PMP-89102 89N01
SPEED
LOCAL
HSS-*SPEED
ETHERNET
IP
CR3-* MWH-*
TSH-*
DI
GENERAL NOTES:
DI
POWER
FSL-*
1 CONVERTER MODULES AS NEEDED FOR FUNCTIONALITY SHOWN.
3. PROVIDE EXPANSION MODULES AND ANY OTHER APPLICABLE
INDICATED LOADS.
2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL FOOTPRINT, WIRING CHANGES, ADDITIONAL CONTROL RELAYS, ETC. OWNER, INCLUDING BUT NOT LIMITED TO DIFFERENCE IN MCC NECESSARY DIFFERENCES WITH NO ADDITIONAL COST TO THE SELECTED, CONTRACTOR IS RESPONSIBLE FOR PROVIDING FOR THE OPERATION SHOWN HERE. IF ANOTHER MANUFACTURER IS MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM
1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
# KEY NOTES:
FILTER
DV/DT
DI REMOTE
HSC-*
START
oox
HSA-*
OFF
LOCAL REMOTE
xoo
STOP
HSB-*
DI STOPDI START
MODULE (HIM)
HUMAN INTERFACE
VFD KEYPAD/
VFD-*
LINE REACTOR
HIGH TEMPERATURELOW FLOW
SWITCH SHALL BE RESET THROUGH TO PCS.FLOW ALARM SIGNAL SHALL BE SENT TO THE PLANT PLC. FLOW SHUT OFF AFTER AN OPERATOR ADJUSTABLE TIMER AND A LOW B. IN A LOW DISCHARGE FLOW CONDITION, THE EQUIPMENT SHALL BE SENT TO THE PLANT PLC. SHALL SHUT OFF AND A HIGH TEMPERATURE ALARM SIGNAL SHALL A. IN A HIGH MOTOR TEMPERATURE CONDITION, THE EQUIPMENT HARDWIRED INTERLOCKS/OVERLOAD PROGRAMMED INTERLOCKS:EQUIPMENT.THE REMOTE POSITION, SCADA/HMI SHALL CONTROL THE E. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN STARTED. THE OFF POSITION, THE EQUIPMENT IS PROHIBITED FROM BEING D. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BY PRESSING THE STOP PUSH BUTTON. THE LOCAL POSITION, AN OPERATOR SHALL STOP THE EQUIPMENT C. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN ADJUSTED USING THE SPEED POTENTIOMETER. THE LOCAL POSITION, THE SPEED OF THE EQUIPMENT SHALL BE B. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BY PRESSING START PUSH BUTTON.THE LOCAL POSITION, AN OPERATOR SHALL START THE EQUIPMENT A. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN
1. HARDWIRED CONTROLS:
PlotDate:12-JUL-202311:47:04AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
KIK
INSTRUMENTATION
8660F10 8660F1006N003.dgn
06N03
CONTROL SCHEMATIC 3
BAL
sshepard
149
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
H1 H3 H2 H4
X1 X2
120V SEC480V PRI1PH CONTROL TRANSFORMER
120VAC
CR3-*
CR
RUNNING
VFD
4 TAG LOOP REFERENCE DWG.
91N01
* = 91100 PMP-91100 91N01
PAU PUMP
HSS-*SPEED
DIDI
POWER
FSL-*
ETHERNET
IP
DI
LSL-*
VFD-*
6 GENERAL NOTES:
# KEY NOTES:
SPEED
LOCAL
TSH-*CR3-* MWH-*
MODULE (HIM)
HUMAN INTERFACE
VFD KEYPAD/
DI
LSHH-*
TM
GND
MOV
480V
M PMP-*
FILTER
DV/DT
CONVERTER MODULES AS NEEDED FOR FUNCTIONALITY SHOWN.
3. PROVIDE EXPANSION MODULES AND ANY OTHER APPLICABLE
INDICATED LOADS.
2. SIZE CONTROL POWER TRANSFORMER IN ACCORDANCE WITH ALL FOOTPRINT, WIRING CHANGES, ADDITIONAL CONTROL RELAYS, ETC. OWNER, INCLUDING BUT NOT LIMITED TO DIFFERENCE IN MCC NECESSARY DIFFERENCES WITH NO ADDITIONAL COST TO THE SELECTED, CONTRACTOR IS RESPONSIBLE FOR PROVIDING FOR THE OPERATION SHOWN HERE. IF ANOTHER MANUFACTURER IS MANUFACTURERS. REVISE SCHEMATIC AS REQUIRED TO PERFORM
1. SCHEMATIC WIRING IS BASED ON ONE OF THE NAMED
DI REMOTE
HSC-*
START
oox
HSA-*
OFF
LOCAL REMOTE
xoo
STOP
HSB-*
DI STOPDI START
LINE REACTOR
LOW FLOWHIGH TEMPERATURELOW LEVELHIGH LEVEL
CAROUSEL PUMP NO. 3.SIGNAL SHALL BE SENT TO THE PLANT PLC TO SHUT DOWN D. IN HIGH HIGH LEVEL CONDITION, A HIGH HIGH LEVEL ALARM AND A LEVEL LOW SIGNAL SHALL BE SENT TO THE PLC.
C. IN LOW LEVEL CONDITION, THE EQUIPMENT SHALL SHUT OFF FLOW SWITCH SHALL BE RESET THROUGH THE PCS.LOW FLOW ALARM SIGNAL SHALL BE SENT TO THE PLANT PLC. SHUT OFF AFTER AN OPERATOR ADJUSTABLE TIMER AND A B. IN A LOW DISCHARGE FLOW CONDITION, THE EQUIPMENT SHALL SHALL BE SENT TO THE PLANT PLC. SHALL SHUT OFF AND A HIGH TEMPERATURE ALARM SIGNAL A. IN A HIGH MOTOR TEMPERATURE CONDITION, THE EQUIPMENT HARDWIRED INTERLOCKS/OVERLOAD PROGRAMMED INTERLOCKS:
EQUIPMENT.THE REMOTE POSITION, SCADA/HMI SHALL CONTROL THE E. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN BEING STARTED. THE OFF POSITION, THE EQUIPMENT IS PROHIBITED FROM D. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN EQUIPMENT BY PRESSING THE STOP PUSH BUTTON. THE LOCAL POSITION, AN OPERATOR SHALL STOP THE C. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN ADJUSTED USING THE SPEED POTENTIOMETER. THE LOCAL POSITION, THE SPEED OF THE EQUIPMENT SHALL BE B. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN EQUIPMENT BY PRESSING START PUSH BUTTON.THE LOCAL POSITION, AN OPERATOR SHALL START THE A. WHEN THE LOCAL-OFF-REMOTE (LOR) SELECTOR SWITCH IS IN
1. HARDWIRED CONTROLS:
PlotDate:12-JUL-202311:46:51AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
KIK
INSTRUMENTATION
8660F10 8660F1006N004.dgn
06N04
CONTROL SCHEMATIC 4
BAL
sshepard
150
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC480V PRI1PH CONTROL TRANSFORMER
M
M O.L.
HSA-*
LOCAL
OFF
REMOTExoo
HSB-*
STOP
HSC-*
START
AUX3-*
MS-*MS-*
RUN
OUTPUT
oox
MS-*
M
3 O.L.'S
oox
HSAR-*
REMOTE
INPUT
AUX1-*
RUNNING
INPUT
AUX1-*
MS-*
SIG COM
TSH-*
INPUT
CR1-*
CR1-*
CR
TAG LOOP REFERENCE DWG.
5 CR1-*
MWH-*
AUX4-*
MS*-
* = 85104 PMP-85104 85N07
TSH-*
PMP-*
* = 87134 PMP-87134 87N01
RAPID MIX PUMP, SAMPLE PUMP
85N07, 87N01
HIGH TEMP
PlotDate:12-JUL-202311:47:17AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
KIK
INSTRUMENTATION
8660F10 8660F1006N005.dgn
06N05
CONTROL SCHEMATIC 5
BAL
151
lbordelon
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC480V PRI1PH CONTROL TRANSFORMER
M
WHERE INDICATED
REMOTE DISCONNECT
HSA-*
LOCAL
OFF
REMOTExoo
HSB-*
STOP
HSC-*
START
CR5-*
CR1-*
CR
TAG LOOP REFERENCE DWG.
6 MWH-*
* = 85106 BLO-85106 85N05* = 85107 BLO-85107 85N05
TSH-*
BLO-*
85N05
AIR WASH BLOWERS
* = 85108 BLO-85108 85N05
MS-*
RUN
OUTPUT
ooxoox
HSAR-*
REMOTE
INPUT
AUX1-*
RUNNING
INPUT
SIG COM
TSH-*
INPUT
AUX2-*
INPUT
VCP-3
PRESS DIFF
CR2-*
CR
PDSH-*
GND
480V
MCP
H1 H3 H2 H4
X1 X2
120V SEC480V PRI1PH CONTROL TRANSFORMER
M
WHERE INDICATED
REMOTE DISCONNECT
M O.L.
FAN-*
CR1-* CR2-* CR3-*
xoo
CR4-*
CR
INPUT
CR3-*
CR
MS-*
M
3 O.L.'S
MS-*
RUN
OUTPUT
AUX1-*
RUNNING
INPUT
VCP-3
AUX1-*
MS-*
TAG LOOP REFERENCE DWG.
FAN-85109 85N05FAN-85110 85N05FAN-85111 85N05
7 85N05
AIR WASH BLOWER FANS
* = 85109, **=85106* = 85110, **=85107
* = 85111, **=85108
AUX3-*
PSH-*
CR2-*
CR1-*
CR3-*
BLOWER FILTER
MOTOR TEMP
DISCHARGE PRESS
CR4-*
BLOWER STARTER
AIR WASH
CR4-**
120VAC
RUNNING
RVSS
RVSS
RUN
CR5-*
RVSS-*
CR6-*
CRCR
CR5-*
CR6-*
CR6-*
STARTERMOTOR BLOWER FAN AIR WASH
PlotDate:12-JUL-202311:47:14AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
KIK
INSTRUMENTATION
8660F10 8660F1006N006.dgn
06N06
CONTROL SCHEMATIC 6
BAL
152
lbordelon
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWER_QUALITY_METER
POWER QUALITY METER POWER MONITOR M500 (PM500)
PROTOCOL: EtherNet/IP
DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK A PH V ü ü üB PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü üB PH CURRENT ü ü ü
C PH CURRENT ü ü ü
A PH DEMAND CURRENT ü üB PH DEMAND CURRENT ü ü
C PH DEMAND CURRENT ü ü
3 PH AVG DEMAND CURRENT ü ü ü
WATTS ü ü ü
VARS ü ü ü
VA ü ü ü
VA DEMAND ü ü ü
W DEMAND ü ü ü
ENERGY ü ü ü
FREQUENCY ü ü
POWER FACTOR ü ü ü
CAROUSEL_PUMP
CAROUSEL PUMP - VFD
PROTOCOL: EtherNet/IP
DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü üB PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü üB PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
DCL_STRUCTURE_VALVE
MULTI-TURN ACTUATOR
PROTOCOL: EtherNet/IP
DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK MOTOR CURRENT ü ü ü
LOCAL ü
OFF ü ü
REMOTE ü
OPEN ü ü
CLOSE ü ü
STOP ü ü
RUNNING CLOSE ü
RUNNING OPEN ü
CLOSE LIMIT ü ü ü
OPEN LIMIT ü ü ü
INSTANTANEOUS TORQUE ü ü ü ü
TORQUE ALARM ü ü ü
HIGH MOTOR TEMPERATURE ü ü ü
WATCHDOG TIMER ü
BATTERY LOW ü
RECYCLED_PUMP
RECYCLED PUMP - VFD
PROTOCOL: EtherNet/IP
DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü üB PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü üB PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
HIGH DISCHARGE PRESSURE ü ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
AWT_CLARIFIER_FILTER
VCP-3
PROTOCOL: EtherNet/IP
DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK HANDSHAKING ü ü
ALL SETPOINTS ü ü
AWT CLARIFIER/FILTER 1 READY üAWT CLARIFIER/FILTER 2 READY üAWT CLARIFIER/FILTER 3 READY üAWT CLARIFIER/FILTER 4 READY ü BACKWASH IN PROGRESS ü
FLUSH IN PROGRESS ü
AIR WASH BLOWER 1 MODE AUTO ü ü
AIR WASH BLOWER 1 MOTOR STATUS STOPPED ü ü
AIR WASH BLOWER 1 MOTOR STATUS RUNNING ü ü
AIR WASH BLOWER 2 MODE AUTO ü ü
AIR WASH BLOWER 2 MOTOR STATUS STOPPED ü ü
AIR WASH BLOWER 2 MOTOR STATUS RUNNING ü ü
AIR WASH BLOWER 3 MODE AUTO ü ü
AIR WASH BLOWER 3 MOTOR STATUS STOPPED ü ü
COAGULANT PUMP 1 STATUS RUNNING OUTPUT ü üCOAGULANT PUMP 2 STATUS RUNNING OUTPUT ü üCOAGULANT PUMP 3 STATUS RUNNING OUTPUT ü ü WASTE GATE VALVE 1 MODE AUTO ü ü
WASTE GATE VALVE 1 MODE POSITION ü ü
BACKWASH VALVE 1 MODE AUTO ü ü
BACKWASH VALVE 1 MODE POSITION ü ü
AC AIR SCOUR VALVE 1 MODE AUTO ü ü
AC AIR SCOUR VALVE 1 MODE POSITION ü ü
WASTE GATE VALVE 2 MODE POSITION ü ü
BACKWASH VALVE 2 MODE POSITION ü ü
AC AIR SCOUR VALVE 2 MODE POSITION ü ü
EFFLUENT VALVE 2 MODE AUTO ü ü
EFFLUENT VALVE 2 MODE POSITION ü ü
AWT CLARIFIER/FILTER 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 3 MODE STATUS ü ü
INFLUENT VALVE 3 MODE AUTO ü ü
AIR VALVE 3 MODE AUTO ü ü
WASTE GATE VALVE 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 4 MODE SEMI-AUTO ü ü
EFFLUENT VALVE 1 MODE POSITION ü ü
AWT CLARIFIER/FILTER 4 MODE AUTO ü ü
AWT CLARIFIER/FILTER 4 MODE STATUS ü ü
INFLUENT VALVE 4 MODE AUTO ü ü
INFLUENT VALVE 4 MODE POSITION ü ü
AIR VALVE 4 MODE AUTO ü ü
AIR VALVE 4 MODE POSITION ü ü
WASTE GATE VALVE 4 MODE AUTO ü ü
WASTE GATE VALVE 4 MODE POSITION ü ü
BACKWASH VALVE 4 MODE AUTO ü ü
AC AIR SCOUR VALVE 4 MODE AUTO ü ü
AC AIR SCOUR VALVE 4 MODE POSITION ü ü
EFFLUENT VALVE 4 MODE AUTO ü ü
EFFLUENT VALVE 4 MODE POSITION ü ü
AWT CLARIFIER/FILTER 1 CALL RUN COMMAND üAWT CLARIFIER/FILTER 2 CALL RUN COMMAND üAWT CLARIFIER/FILTER 4 CALL RUN COMMAND ü AWT CLARIFIER/FILTER 4 INLET FLOW ü ü ü ü
COAGULANT FEED PUMP 1 COMMAND SPEED üCOAGULANT FEED PUMP 2 COMMAND SPEED üCOAGULANT FEED PUMP 3 COMMAND SPEED ü AWT CLARIFIER/FILTER 3 INLET FLOW ü ü ü ü
INFLUENT VALVE 3 MODE POSITION ü ü
WASTE GATE VALVE 3 MODE POSITION ü ü
BACKWASH VALVE 3 MODE AUTO ü ü
EFFLUENT VALVE 3 MODE POSITION ü ü
BACKWASH VALVE 4 MODE POSITION ü ü
AWT CLARIFIER/FILTER 1 MODE SEMI-AUTO ü ü
AWT CLARIFIER/FILTER 1 MODE AUTO ü ü
AWT CLARIFIER/FILTER 1 MODE STATUS ü ü
INFLUENT VALVE 1 MODE AUTO ü ü
INFLUENT VALVE 1 MODE POSITION ü ü
AIR VALVE 1 MODE AUTO ü ü
AIR VALVE 1 MODE POSITION ü ü
EFFLUENT VALVE 1 MODE AUTO ü ü
INFLUENT VALVE 2 MODE POSITION ü ü
BACKWASH VALVE 3 MODE POSITION ü ü
AC AIR SCOUR VALVE 3 MODE AUTO ü ü
AC AIR SCOUR VALVE 3 MODE POSITION ü ü
EFFLUENT VALVE 3 MODE AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE SEMI-AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE AUTO ü ü
AWT CLARIFIER/FILTER 2 MODE STATUS ü ü
INFLUENT VALVE 2 MODE AUTO ü ü
AIR VALVE 2 MODE AUTO ü ü
AIR VALVE 2 MODE POSITION ü ü
WASTE GATE VALVE 2 MODE AUTO ü ü
BACKWASH VALVE 2 MODE AUTO ü ü
AC AIR SCOUR VALVE 2 MODE AUTO ü ü
AWT CLARIFIER/FILTER 3 MODE SEMI-AUTO ü ü
AIR VALVE 3 MODE POSITION ü ü
AWT CLARIFIER/FILTER 3 CALL RUN COMMAND ü
BACKWASH STATION LOW LEVEL OUTPUT ü
BACKWASH STATION HIGH LEVEL OUTPUT ü
AWT CLARIFIER/FILTER 1 INLET FLOW ü ü ü üAWT CLARIFIER/FILTER 2 INLET FLOW ü ü ü ü AIR WASH BLOWER 3 MOTOR STATUS RUNNING ü ü
PAU_PUMP
PAU PUMP - VFD
PROTOCOL: EtherNet/IP
DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü
OFF ü ü
REMOTE ü
STOP ü ü
START ü ü
SPEED ü ü
SPEED FEEDBACK ü ü ü
RESET ELAPSED TIME ü ü
RUNNING ü ü ü
TOTAL STARTS ü ü ü
DAILY STARTS ü ü ü
ELAPSED TIME ü ü ü
DAILY RUN TIME ü ü ü
A PH V ü ü üB PH V ü ü ü
C PH V ü ü ü
A PH CURRENT ü ü üB PH CURRENT ü ü ü
C PH CURRENT ü ü ü
AVERAGE 3 PH CURRENT ü ü ü
POWER KVA ü ü ü
POWER KW ü ü ü
POWER FACTOR ü ü ü
CURRENT ALARM HIGH ü ü ü
OVERLOAD ü ü ü
FAULT ü ü ü ü
FAIL TO RESPOND ü ü ü
VOLTAGE ü ü ü ü
LOW FLOW ü ü ü
LOW LEVEL ü ü ü
HIGH MOISTURE DETECTION ü ü ü
HIGH TEMPERATURE DETECTION ü ü ü
PlotDate:12-JUL-202311:46:31AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
DB
DKI
INSTRUMENTATION
8660F10 8660F1009N001.dgn
09N01
PCS I/O TABLES
BAL
153
MHood
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PUMP STATION
TO CAROUSEL
FACILITY
FROM CHLORINATION
FV-60100
DCL STRUCTURE VALVE 1
5HP 480VAC 3PH
AE-60101
CHLORINE ANALYZER 4
0-10 MG/L
AE
60101
CHLORINE
AIT
60101
CB
60101
TM120VAC-1PPCM-70299
E
FV-60102
DCL STRUCTURE VALVE 2
5HP 480VAC 3PH
INJECTION STRUCTURE
FROM SODIUM BISULFATE
RIVER
TO RUSSIAN
EX- 42"
EX- 24" FE
EX- 42" RCP
POWERSOURCE
FIELD
I/O
EX- 30" WSP
FV
60100
VAL
60100
A
60101
AICLPLC-70299
E
DRAIN
REAGENT
DRAIN
PROCESS
PMP-60101
DCL CHLORINE SAMPLE PUMP
PMP
60101
E
M
PI-60101
PRESSURE INDICATOR
0-30 PSI
PI
60101
PRESSURE
FI
60101
CHLORINE
FI-60101
CHLORINE SAMPLE FLOW INDICATOR
0-500 ML/MIN
VAL
60102
FV
60102
TYP
* NA090
CB
60100
TM480VAC-3PMCC70291
FVC
60100
EIPPLC-70299
DCL_STRUCTURE_VALVE
CB
60102
TM480VAC-3PMCC70291
FVC
60102
EIPPLC-70299
DCL_STRUCTURE_VALVE
PMP-60135
CHLORINE BASIN SAMPLE PUMP
DISC
60009
E
CB
60009
TM480VAC-3PMCC70291
E
HSG
60009
E OSC
HSA
60009
E LSR
FCV-60009
DCL STRUCT CHLORINE VALVE
E
D
HSAR
60009
DIREMOTEPLC-70299
E
ZSC
60009
DICLOSEDPLC-70299
E
ZSO
60009
DIOPENEDPLC-70299
E
ZCO
60009
DOOPENPLC-70299
E
ZCC
60009
DOCLOSEPLC-70299
E
M
DRAIN
PROCESS
PMP
60135
E
FCV
60009
E
VAL
60009
E
LCP
60009
E
HSA
60009
E LSR
HSG
60009
E OSC
ZSOC
60009
E
CHLORINE BASIN
1 1
# KEY NOTES:
AND BE INSTALLED IN THE EXISTING ENCLOSURE.
2. THE NEW ANALYZER SHALL REPLACE THE EXISTING ANALYZER ETHERNET SWITCH IN PANEL PLC-70299.
1. ETHERNET CONNECTION SHALL BE CONNECTED TO THE EXISTING DISC
60100
HSG
60100
OSC
HSA
60100
LSR
DISC
60102
HSG
60102
OSC
HSA
60102
LSR
ZSOC
60100
HSG
60100
OSC
HSA
60100
LSR
LCP
60100
ZSOC
60102
HSG
60102
OSC
HSA
60102
LSR
LCP
60102
E
D
E
D
2 PlotDate:12-JUL-202311:49:00AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
60N01
154
INSTRUMENTATION
DECHLORINATION STRUCTURE P&ID
8660F10 8660F1060N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PIPE - SEGMENT 2
FROM CHLORINE CONTACT
LE-80100
STRUCT 80 LEVEL
0-18 FT
LE
80100
ULTRASONIC
LIT
80100
TYP
* NL175
POWERSOURCE
FIELD
I/O
L
80100
AIPLC-70299
PUMP STATION
TO AWT
LSL
80011
E
LE-80011
LOW LEVEL SWITCH
LE
80011
E FLOAT
MM
FE-80002
RECLAIMED WATER FLOW TRANSMITTER
FE
80002
E MAGNETIC
FIT
80002
E
CB
80002
TM120VAC-1PPCM
E
LSL
80012
E
LE-80012
LOW LEVEL SWITCH
LE
80012
E FLOAT
LSL
80013
E
LE-80013
LOW LEVEL SWITCH
LE
80013
E FLOAT
96" SE
PUMP STATION
TO CAROUSEL
17 91N0180N01
PUMP STATION
FROM PAU
WATER FILTER
TO RECLAIMED
30" FE
42" SE
6"RCW
6"RCW
6"RCW
8" RCW
PMP
80111
E
PMP-80111
RECLAIMED WATER FILTER FEED PUMP 1
PMP
80112
E
PMP-80112
RECLAIMED WATER FILTER FEED PUMP 2
PMP
80113
E
PMP-80113
RECLAIMED WATER FILTER FEED PUMP 3
16" RW
PlotDate:12-JUL-202311:49:39AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
80N01
155
INSTRUMENTATION
STRUCTURE 80 P&ID
8660F10 8660F1080N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
MM
FE-85211
FLOW TRANSMITTER AWT CLARIFIER/FILTER 1
FE
85211
E MAGNETIC
FIT
85211
E
FV-85212
AIR VALVE NO.1
0.5HP 480VAC 3PH
DISC
85212
CB
85212
TM480VAC-3PDP2
E
M
VAL
85211
FBV
LSH
85101
FLOATFBV
TYP
* LE1-85101 NL101
HIGH LEVEL SWITCH FILTER 1
7.17 FT
LE2-85101
LOW LEVEL SWITCH FILTER 1
6.17 FT
LE2
85101
FLOATFBV
LSL
85101
FLOATFBV
TYP
* NL101
FCV-85218
EFFLUENT VALVE NO.1
1HP 480VAC 3PH
E
M
DISC
85218
FV-85217
BACKWASH VALVE NO.1
1.5HP 480VAC 3PH
DISC
85217
CLARIFIER
FILTER
20" WW
6" AA
TANK NO. 1
12" FE
ONP&ID85N02
CONTINUED
FV
85212
FBV
HSA
85212
LSRFBV
HSG
85212
OSCFBV
ZSOC
85212
FBV
VAL
85212
FBV
GAT
85214
E
FCV-85211
INFLUENT VALVE NO.1
1HP 480VAC 3PH
DISC
85211
ZT
85211
FBV
HSA
85211
LSRFBV
HSG
85211
OSCFBV
ZSOC
85211
FBV
FCV
85211
FBV
FBV
FBV
FV-85214
WASTE GATE VALVE NO.1
1HP 480VAC 3PH
DISC
85214
FV
85214
FBV
ZSOC
85214
FBV
HSG
85214
OSCFBV
HSA
85214
LSRFBV
FCV
85218
FBV
FBV
ZSOC
85218
FBV
HSG
85218
OSCFBV
HSA
85218
LSRFBV
ZT
85218
FBV
VAL
85218
FBV
FBV
FV
85217
FBV
ZSOC
85217
FBV
HSG
85217
OSCFBV
HSA
85217
LSRFBV
VAL
85217
FBV
VCP
3 LE1
85101
FLOATFBV
CF
3 EIPPLC-4
AWT_CLARIFIER_FILTER
PDIT
85213
E
PDIT
85216
E
12" FE
PE-85213
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85213
E PRESS DIFF
PE-85216
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85216
E PRESS DIFF
PUMP STATION
BACKWASH
14 85N04
85N01
TANK NO. 4 FILTER
13 85N03
85N01
TANK NO. 3 FILTER
12 85N02
85N01
TANK NO. 2 FILTER
PUMP STATION
BACKWASH
5 85N05
85N01
AIR WASH BLOWERS
VAL
85219
FBV
DISC
85219
CB
85219
TM480VAC-3PDP2
ZSOC
85219
FBV
HSA
85219
LSRFBV
HSG
85219
OSCFBV
FV-85219
AC AIR SCOUR VALVE NO. 1
0.5HP 480VAC 3PH
E
D
FV
85219
FBV
RECOVERY BASINS
WASHWATER
AWT PUMPS
AIR WASH BLOWERS
15 85N01
85N08
9 85N01
85N02
10 85N01
85N03
11 85N01
85N04
16 85N01
85N08
20" BW/FE
12" FE
CB
85210
TM120VAC-1PPNL-A
FBV
E
D
E
D
E
D
24" FE
TYP
* LE-85211 NL180
RADAR PTOF
LE
85211
RADAR PTOFFBV
LIT
85211
FBV
8" AA
PlotDate:12-JUL-202311:49:31AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
85N01
156
INSTRUMENTATION
AWT CLARIFIER/FILTER 1 P&ID
8660F10 8660F1085N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
MM
FE-85221
FLOW TRANSMITTER AWT CLARIFIER/FILTER 2
FE
85221
E MAGNETIC
FIT
85221
E
FV-85222
AIR VALVE NO.2
0.5HP 480VAC 3PH
DISC
85222
CB
85222
TM480VAC-3PDP2
E
M
VAL
85221
FBV
LSH
85102
FLOATFBV
TYP
* LE1-85102 NL101
HIGH LEVEL SWITCH FILTER 2
7.17 FT
LE2-85102
LOW LEVEL SWITCH FILTER 2
6.17 FT
LE2
85102
FLOATFBV
LSL
85102
FLOATFBV
TYP
* NL101
FCV-85228
EFFLUENT VALVE NO.2
1HP 480VAC 3PH
E
M
DISC
85228
FV-85227
BACKWASH VALVE NO.2
1.5HP 480VAC 3PH
DISC
85227
20" WW
12" FE
6" AA
TANK NO. 2
12" FE
ONP&ID85N03
CONTINUED
FV
85222
FBV
HSA
85222
LSRFBV
HSG
85222
OSCFBV
ZSOC
85222
FBV
VAL
85222
FBV
FCV-85221
INFLUENT VALVE NO.2
1HP 480VAC 3PH
DISC
85221
ZT
85221
FBV
HSA
85221
LSRFBV
HSG
85221
OSCFBV
ZSOC
85221
FBV
FCV
85221
FBV
FBV
FBV
FV-85224
WASTE GATE VALVE NO.2
1HP 480VAC 3PH
DISC
85224
FV
85224
FBV
ZSOC
85224
FBV
HSG
85224
OSCFBV
HSA
85224
LSRFBV
FCV
85228
FBV
FBV
ZSOC
85228
FBV
HSG
85228
OSCFBV
HSA
85228
LSRFBV
ZT
85228
FBV
VAL
85228
FBV
FBV
FV
85227
FBV
ZSOC
85227
FBV
HSG
85227
OSCFBV
HSA
85227
LSRFBV
VAL
85227
FBV
ONP&ID85N01
CONTINUED
LE1
85102
FLOATFBV
CLARIFIER FILTER
GAT
85224
E
VCP-3
PDIT
85223
E
PDIT
85226
E
PE-85223
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85223
E PRESS DIFF
PE-85226
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85226
E PRESS DIFF
DISC
85229
CB
85229
TM480VAC-3PDP2
FV-85229
AC AIR SCOUR VALVE NO. 2
0.5HP 480VAC 3PH
E
D
12 85N02
85N01
PUMP STATION
BACKWASH
PUMP STATION
BACKWASH
6 85N05
85N02
AIR WASH BLOWERS
RECOVERY BASINS
WASHWATER
9 85N01
85N02
AWT PUMPS
AIR WASH BLOWERS
FV
85229
FBV
VAL
85229
FBV
ZSOC
85229
FBV
HSG
85229
OSCFBV
HSA
85229
LSRFBV
12"FE
20" BW/FE
14" BW
FBV
E
D
E
D
E
D
TYP
* LE-85221 NL180
RADAR PTOF
LE
85221
RADAR PTOFFBV
LIT
85221
FBV
FBV
8" AA
PlotDate:12-JUL-202311:50:49AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
85N02
157
INSTRUMENTATION
AWT CLARIFIER/FILTER 2 P&ID
8660F10 8660F1085N002.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
MM
FE-85231
FLOW TRANSMITTER AWT CLARIFIER/FILTER 3
FE
85231
E MAGNETIC
FIT
85231
E
FV-85232
AIR VALVE NO.3
0.5HP 480VAC 3PH
DISC
85232
CB
85232
TM480VAC-3PDP2
E
M
VAL
85231
FBV
LSH
85103
FLOATFBV
TYP
* LE1-85103 NL101
HIGH LEVEL SWITCH FILTER 3
7.17 FT
LE2-85103
LOW LEVEL SWITCH FILTER 3
6.17 FT
LE2
85103
FLOATFBV
LSL
85103
FLOATFBV
TYP
* NL101
FCV-85238
EFFLUENT VALVE NO.3
1HP 480VAC 3PH
E
M
DISC
85238
FV-85237
BACKWASH VALVE NO.3
1.5HP 480VAC 3PH
DISC
85237
20" WW
12" FE
6" AA
TANK NO. 3
ONP&ID85N04
CONTINUED
FV
85232
FBV
HSA
85232
LSRFBV
HSG
85232
OSCFBV
ZSOC
85232
FBV
VAL
85232
FBV
FCV-85231
INFLUENT VALVE NO.3
1HP 480VAC 3PH
DISC
85231
ZT
85231
FBV
HSA
85231
LSRFBV
HSG
85231
OSCFBV
ZSOC
85231
FBV
FCV
85231
FBV
FBV
FBV
FV-85234
WASTE GATE VALVE NO.3
1HP 480VAC 3PH
DISC
85234
FV
85234
FBV
ZSOC
85234
FBV
HSG
85234
OSCFBV
HSA
85234
LSRFBV
FCV
85238
FBV
FBV
ZSOC
85238
FBV
HSG
85238
OSCFBV
HSA
85238
LSRFBV
ZT
85238
FBV
VAL
85238
FBV
FBV
FV
85237
FBV
ZSOC
85237
FBV
HSG
85237
OSCFBV
HSA
85237
LSRFBV
VAL
85237
FBV
ONP&ID85N02
CONTINUED
LE1
85103
FLOATFBV
CLARIFIER
FILTER
GAT
85234
E
VCP-3
PDIT
85233
E
PDIT
85236
E
PE-85233
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85233
E PRESS DIFF
PE-85236
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85236
E PRESS DIFF
DISC
85239
CB
85239
TM480VAC-3PDP2
FV-85239
AC AIR SCOUR VALVE NO. 3
0.5HP 480VAC 3PH
E
D
13 85N03
85N01
PUMP STATION
BACKWASH
PUMP STATION
BACKWASH
7 85N05
85N03
AIR WASH BLOWERS
RECOVERY BASINS
WASHWATER
10 85N01
85N03
AWT PUMPS
AIR WASH BLOWERS
FV
85239
FBV
ZSOC
85239
FBV
VAL
85239
FBV
HSG
85239
OSCFBV
HSA
85239
LSRFBV
12"FE
20" BW/FE
14" BW
FBV
FBV
E
D
E
D
18" FE
E
D
TYP
* LE-85231 NL180
RADAR PTOF
LE
85231
RADAR PTOFFBV
LIT
85231
8" AA
PlotDate:12-JUL-202311:49:53AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
85N03
158
INSTRUMENTATION
AWT CLARIFIER/FILTER 3 P&ID
8660F10 8660F1085N003.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
MM
FE-85241
FLOW TRANSMITTER AWT CLARIFIER/FILTER 4
FE
85241
E MAGNETIC
FIT
85241
E
FV-85242
AIR VALVE NO.4
0.5HP 480VAC 3PH
DISC
85242
CB
85242
TM480VAC-3PDP2
E
M
VAL
85241
FBV
LSH
85104
FLOATFBV
TYP
* LE1-85104 NL101
HIGH LEVEL SWITCH FILTER 4
7.17 FT
LE2-85104
LOW LEVEL SWITCH FILTER 4
6.17 FT
LE2
85104
FLOATFBV
LSL
85104
FLOATFBV
TYP
* NL101
FCV-85248
EFFLUENT VALVE NO.4
1HP 480VAC 3PH
E
M
DISC
85248
FV-85247
BACKWASH VALVE NO.4
1.5HP 480VAC 3PH
DISC
85247
20" WW
12" FE
TANK NO. 4
ONP&ID85N05
CONTINUED
FV
85242
FBV
HSA
85242
LSRFBV
HSG
85242
OSCFBV
ZSOC
85242
FBV
VAL
85242
FBV
FCV-85241
INFLUENT VALVE NO.4
1HP 480VAC 3PH
DISC
85241
ZT
85241
FBV
HSA
85241
LSRFBV
HSG
85241
OSCFBV
ZSOC
85241
FBV
FCV
85241
FBV
FBV
FBV
FV-85244
WASTE GATE VALVE NO.4
1HP 480VAC 3PH
DISC
85244
FV
85244
FBV
ZSOC
85244
FBV
HSG
85244
OSCFBV
HSA
85244
LSRFBV
FCV
85248
FBV
FBV
ZSOC
85248
FBV
HSG
85248
OSCFBV
HSA
85248
LSRFBV
ZT
85248
FBV
VAL
85248
FBV
FBV
FV
85247
FBV
ZSOC
85247
FBV
HSG
85247
OSCFBV
HSA
85247
LSRFBV
VAL
85247
FBV
ONP&ID85N03
CONTINUED
LE1
85104
FLOATFBV
CLARIFIER
FILTER
GAT
85244
E
VCP-3
PDIT
85243
E
PDIT
85246
E
PE-85243
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85243
E PRESS DIFF
PE-85246
PRESSURE DIFFERENTIAL TRANSMITTER
PE
85246
E PRESS DIFF
DISC
85249
CB
85249
TM480VAC-3PDP2
FV-85249
AC AIR SCOUR VALVE NO. 4
0.5HP 480VAC 3PH
E
D
14 85N04
85N01
PUMP STATION
BACKWASH
PUMP STATION
BACKWASH
8 85N05
85N04
AIR WASH BLOWERS
RECOVERY BASINS
WASHWATER
11 85N01
85N04
AWT PUMPS
AIR WASH BLOWERS
FV
85249
FBV
ZSOC
85249
FBV
HSG
85249
OSCFBV
VAL
85249
FBV
HSA
85249
LSRFBV
12"FE
20" BW/FE
14" BW
FBV
FBV
E
D
E
D
E
D
TYP
* LE-85241 NL180
RADAR PTOF
LE
85241
RADAR PTOFFBV
LIT
85241
FBV
8" AA
6" AA
PlotDate:12-JUL-202311:49:50AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
85N04
159
INSTRUMENTATION
AWT CLARIFIER/FILTER 4 P&ID
8660F10 8660F1085N004.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
BLO-85106
AIR WASH BLOWER 1
20HP 480VAC 3PH
MWH
85106
TSH
85106
BLO
85106
6 06N06
4" AA
POWERSOURCE
FIELD
I/O
BLO-85107
AIR WASH BLOWER 2
20HP 480VAC 3PH
4" AA
BLO-85108
AIR WASH BLOWER 3
20HP 480VAC 3PH
4" AA
BLO
85107
BLO
85108
TSH
85107
MWH
85107
TSH
85108
MWH
85108
FE-85105
AIR WASH VENTURI FLOWMETER
FE
85105
E VENTURI
FIT
85105
E SORT
F
85105
AIPLC-4
E
PI-85100
PRESSURE INDICATOR
PI
85100
FBV
TYP
* PE-85100 NP501
LOW PRESSURE SWITCH
PE
85100
PRESS SWFBV
PSL
85100
FBV
VCP-3 CONTINUED
FROM85N04
CONTINUED
PRESS DIFF
TEMP
RUNNING
REMOTE
RUN
PRESS DIFF
TEMP
RUNNING
REMOTE
RUN
PRESS DIFF
TEMP
RUNNING
REMOTE
RUN
5 85N05
85N01
FILTER NO. 1
OUTSIDE AIR
6 85N05
85N02
FILTER NO. 2
7 85N05
85N03
FILTER NO. 3
8 85N05
85N04
FILTER NO. 4
CLARIFIER NO. 1
CLARIFIER NO. 2
CLARIFIER NO. 3
CLARIFIER NO. 4
OUTSIDE AIROUTSIDE AIR
RVSS-85106
RVSS
480VAC-3P
MCC-C
RVSS-85107
RVSS
480VAC-3P
MCC-C
RVSS-85108
RVSS
480VAC-3P
MCC-C
HSB
85108
STOP
HSC
85108
START
HSA
85108
LOR
HSB
85107
STOP
HSC
85107
START
HSA
85107
LOR
HSB
85106
STOP
HSC
85106
START
HSA
85106
LOR
LCP
85106
LCP
85108
LCP
85107
ON85N08
CONTINUED
PE1-85106
FILTER DIFFERENTIAL PRESSURE 1
PE1
85106
PRESS DIFFFBV
PDSH
85106
FBV
TYP
* NP188 PE1-85107
FILTER DIFFERENTIAL PRESSURE 2
PE1
85107
PRESS DIFFFBV
PDSH
85107
FBV
TYP
* NP188 PE1-85108
FILTER DIFFERENTIAL PRESSURE 3
PE1
85108
PRESS DIFFFBV
PDSH
85108
FBV
TYP
* NP188
TYP
* PE2-85106 NP501
PRESSURE SWITCH HIGH
PE2
85106
PRESS SWFBV
PSH
85106
FBV
PE3-85106
PRESSURE TRANSMITTER
PE3
85106
PRESSUREFBV
PIT
85106
FBV
TYP
* NP501
FAN
85109
MS-85109
FVNR
480VAC-3P
MCC-C
MS-85110
FVNR
480VAC-3P
MCC-C
MS-85111
FVNR
480VAC-3P
MCC-C
PE2-85107
PRESSURE SWITCH HIGH
PE2
85107
PRESS SWFBV
PSH
85107
FBV
PE3-85107
PRESSURE TRANSMITTER
PE3
85107
PRESSUREFBV
PIT
85107
FBV
PE2-85108
PRESSURE SWITCH HIGH
PE2
85108
PRESS SWFBV
PSH
85108
FBV
PE3-85108
PRESSURE TRANSMITTER
PE3
85108
PRESSUREFBV
PIT
85108
FBV
PRESS PRESS PRESS
PERMISSIVE
PERMISSIVE
PERMISSIVE
RUNNING
RUN
RUNNING
RUN
RUNNING
RUN
TYP
* NP501
TYP
* NP501
TYP
* NP501
TYP
* 6 NP501
06N06
6 06N06
7 06N06
7 06N06
7 06N06
FAN
85110
FAN
85111
8" AA 8" AA
8"AA
EX-6" AA
PlotDate:12-JUL-202311:48:40AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
85N05
160
INSTRUMENTATION
AIR WASH BLOWERS 1, 2 & 3 P&ID
8660F10 8660F1085N005.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
LE-85180
TNK 2 LEVEL
LE
85180
E ULTRASONIC
LIT
85180
E
CB
85180
TM120VAC-1PPCM-4
E
PMP-85181
COAGULANT FEED PUMP NO. 1
0.5HP 90VDC
PMP
85181
FBV
E
VCP
85181
FBV
E
CB
85181
TM120VAC-1PPNL-A
E
PMP-85182
COAGULANT FEED PUMP NO. 2
0.5HP 90VDC
CB
85182
TM120VAC-1PPNL-A
E
PMP-85183
COAGULANT FEED PUMP NO. 3
0.5HP 90VDC
CB
85183
TM120VAC-1PPNL-A
E
WITH FERRIC CHLORIDE
TANK 2
EX-1 1/2" FC
POWERSOURCE
FIELD
I/O
L
85180
AIPLC-4
E
AUX1
85181
DIRUNNINGPLC-4
E
AUX2
85181
DIE-STOPPLC-4
E
AUX1
85182
DIRUNNINGPLC-4
E
AUX2
85182
DIE-STOPPLC-4
E
VCP
85182
FBV
E
PMP
85182
FBV
E
VCP
85183
FBV
E
AUX1
85183
DIRUNNINGPLC-4
E
AUX2
85183
DIE-STOPPLC-4
E
PMP
85183
FBV
NPW
18 85N0685N07
TO AWT RAPID MIX
S
S
S
FI
85181
E
FI-85181
ROTAMETER 1
0-5 GPM
FI
85182
E
FI-85182
ROTAMETER 2
0-5 GPM
FI
85183
E
FI-85183
ROTAMETER 3
0-5 GPM
SS
85182
AOSPEED OUTPLC-4
E
SS
85183
AOSPEED OUTPLC-4
E
SS
85181
AOSPEED OUTPLC-4
E
NPW - 2"
1 # KEY NOTES:
ENCLOSURE.
1. INSTALL NEW DC DRIVE AND ENCODER IN THE EXISTING
PlotDate:12-JUL-202311:48:52AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
85N06
161
INSTRUMENTATION
COAGULANT FEED PUMP P&ID
8660F10 8660F1085N006.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
CHLORINATION FACILITY CLARIFIER/FILTER UNITS
FROM
PMP-85104
RAPID MIX PUMP
7.5HP 480VAC 3PH
5 06N05
ASSEMBLY
FLASH MIX
3" FE
POWERSOURCE
FIELD
I/O
MS
85104
DORUNPLC-4
HSAR
85104
DIREMOTEPLC-4
TSH
85104
DIHIGH TEMPPLC-4
AUX1
85104
DIRUNNINGPLC-4
MWH
85104
TSH
85104
PMP
85104
FVNR-85104
FVNR
480VAC-3P
MCC-C
HSB
85104
STOP
HSC
85104
START
HSA
85104
LOR
LCP
85104
18 85N0685N07
COAGULANT FEED
FROM
EX-24" FE
PlotDate:12-JUL-202311:49:02AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
85N07
162
INSTRUMENTATION
RAPID MIX PUMP P&ID
8660F10 8660F1085N007.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
VCP-3
FROM85N05
CONTINUED
16 85N01
85N08
RCW
15 85N01
85N08
RCW
M
AE-85108
pH
AE
85108
E pH
AIT
85108
E
AE-85109
TURBIDITY
AE
85109
E TURBIDITY
AIT
85109
E
AE-85110
pH
AE
85110
E pH
AIT
85110
E
AE-85111
TURBIDITY
AE
85111
E TURBIDITY
AIT
85111
E
PMP
85112
E
PMP-85112
TO DRAIN
TO DRAIN
SINK
TO SAMPLE
SINK
TO SAMPLE
SHEET87N01
CONTINUEDON
PlotDate:12-JUL-202311:51:01AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
LMB
BAL
85N08
163
INSTRUMENTATION
EXISTING CHLORINATION FACILITY
ANALYZERS P&ID
8660F10 8660F1085N008.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
FROM AWT
19 87N0188N01
BASINS
TO CHLORINE CONTACT
PMP-87132
BACKWASH PUMP NO. 1
AE-87130
CHLORINE ANALYZER 3
0-10 MG/L
AE
87130
CL
AIT
87130
CB1
87130
TM120VAC-1PPCM-4
TYP
* NA090 PMP-87133
BACKWASH PUMP 2
LE/LSH-87130
HIGH LEVEL SWITCH
LSH
87130
E
LE-87130
LOW LEVEL SWITCH
LE
87130
E
LSL
87130
E
FROM HOCL
20 87N0188N01
BASINS
TO CHLORINE CONTACT
TO AWT BUILDING
14" BW
24" FE
24" FE 24" FE
2" CLS
POWERSOURCE
FIELD
I/O
LSL
87130
DIPLC-4
E
LSH
87130
DIPLC-4
E
A
87130
AICLPLC-4
MWH
87132
E
TSH
87132
E
AUX1
87132
DIREADYPLC-4
E
AUX2
87132
DIFAILEDPLC-4
E
MS
87132
DORUNPLC-4
E
PMP
87132
E
MWH
87133
E
TSH
87133
E
AUX1
87133
DIREADYPLC-4
E
AUX2
87133
DIFAILEDPLC-4
E
MS
87133
DORUNPLC-4
E
PMP
87133
E
LE/LSH
87130
E
HSA
87133
E HOA
HSC
87133
E RUN
HSB
87133
E OFF
HSA
87132
E HOA
HSC
87132
E RUN
HSB
87132
E OFF
LCP
87132
E
LCP
87133
E
PMP-87134
BACKWASH CHLORINE SAMPLE PUMP
0.5HP 480VAC 3PH
FVNR-87134
FVNR
480VAC-3P
MCC-C
HSB
87134
STOP
HSC
87134
START
HSA
87134
LOR
5 06N05
PMP
87134
M
PI
87130
PRESSURE
PI-87130
PRESSURE INDICATOR
0-30 PSI
FI
87130
CHLORINE
FI-87130
CHLORINE SAMPLE FLOW INDICATOR
0-500 ML/MIN
DRAIN
PROCESS
DRAIN
REAGENT
MWH
87134
TSH
87134
LCP
87134
MS-87133
FVNR
480VAC-3P
MCCE MS-87132 FVNR 0VAC-2P MCC- E
AUX1
87134
DIRUNNINGPLC-4
TSH
87134
DIHIGH TEMPPLC-4
HSAR
87134
DIREMOTEPLC-4
MS
87134
DORUNPLC-4
1 # KEY NOTES:
AND BE INSTALLED IN THE EXISTING ENCLOSURE.
1. THE NEW ANALYZER SHALL REPLACE THE EXISTING ANALYZER DISC
87130
FV-87130
HIGH RATE BACKWASH VALVE
1HP 480VAC 3PH
M
FV
87130
FBV
FROM85N08
CONTINUED
8" BW
ZSOC
87130
FBV
HSG
87130
OSCFBV
HSA
87130
LSRFBV
VAL
87130
FBV
CB2
87130
TM480VAC-3PDP2
VCP-3
VCP
87130
PlotDate:12-JUL-202311:47:43AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
87N01
164
INSTRUMENTATION
BACKWASH PUMP STATION
CHLORINE ANALYZER P&ID
8660F10 8660F1087N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
19 87N0188N01
PUMPING STATION
BACKWASH
POWERSOURCE
FIELD
I/O
LE-88101
CHLORINE CONTACT BASIN OPEN CHANNEL FLOW METER 1
600-1500 GPM
LE
88101
ULTRASONIC
FIT
88101
CB
88101
TM120VAC-1PPCM-4
TYP
* NA901
F
88101
AIPLC-4
LE-88102
CHLORINE CONTACT BASIN OPEN CHANNEL FLOW METER 2
600-1500 GPM
LE
88102
ULTRASONIC
FIT
88102
CB
88102
TM120VAC-1PPCM-4
F
88102
AIPLC-4
20 87N0188N01
PUMPING STATION
BACKWASH
INJECTION STRUCTURE
SODIUM BISULFITE
INJECTION STRUCTURE
SODIUM BISULFITE
TYP
* NA901
24" FE24" FE 24" FE
24" FE
CHLORINE CONTACT BASIN 1
CHLORINE CONTACT BASIN 2
PlotDate:12-JUL-202311:51:54AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
LMB
BAL
88N01
165
INSTRUMENTATION
CHLORINE CONTACT BASIN
FLOW METERS P&ID
8660F10 8660F1088N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
PMP-89100
CAROUSEL PUMP 1
40HP 480VAC 3PH
HSS
89100
SPEED
VFD-89100
VFD-6
480VAC-3P
3 06N03
HSB
89100
STOP
HSC
89100
START
HSA
89100
LOR
PMP-89102
CAROUSEL PUMP 3
40HP 480VAC 3PH
HSS
89102
SPEED
VFD-89102
VFD-6
480VAC-3P
MCC70293
3 06N03
HSB
89102
STOP
HSC
89102
START
HSA
89102
LOR
PMP-89101
CAROUSEL PUMP 2
40HP 480VAC 3PH
PMP
89101
E
MWH
89101
TSH
89101
HSS
89101
SPEED
VFD-89101
VFD-6
480VAC-3P
MCC70292
HSB
89101
STOP
HSC
89101
START
HSA
89101
LOR
LCP
89101
3 06N03
LCP
89100
MWH
89100
TSH
89100
PMP
89100
E
LCP
89102
MWH
89102
TSH
89102
PMP
89102
TYP
* LE-89103 NL153
CAROUSEL LEVEL TRANSMITTER
0-19.5 FT
LE
89103
RADAR PTOF
LIT
89103
L
89103
AIPLC-70299
TYP
* FE-89100 NF111
LOW FLOW SWITCH
400 GPM
FE
89100
THERMAL
FSL
89100
VFD
89101
EIPPLC-70299
CAROUSEL_PUMP
VFD
89102
EIPPLC-70299
CAROUSEL_PUMP
VFD
89100
EIPPLC-70299
CAROUSEL_PUMP
FE-89101
LOW FLOW SWITCH
400 GPM
FE
89101
THERMAL
FSL
89101
FE-89102
LOW FLOW SWITCH
2000 GPM
FE
89102
THERMAL
FSL
89102
TYP
* NF111
TYP
* NF111
FACILITY
CHLORINATION
POND NO. 3 (NORTH)
POND NO. 2 (SOUTH)
POND NO. 1 (MIDDLE)
PAU
LE-89100
HIGH HIGH AND LOW LOW LEVEL SWITCHES
LE
89100
FLOAT
LSLL
89100
2 FT
LSHH
89100
17.5 FT
TYP
* NL100
LSLL
89100
DIPLC-70299
LSHH
89100
DIPLC-70299
CB
89100
TM480VAC-3PMCC70291
CB
89101
TM480VAC-3PMCC70292
CB
89102
TM480VAC-3PMCC70293
1 1
# KEY NOTES:
TO ELECTRICAL DRAWINGS FOR FURTHER DETAIL.
1. EXISTING MOTOR SHALL BE REPLACED WITH NEW ONE. REFER PlotDate:12-JUL-202311:49:42AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
TCD
BAL
89N01
166
INSTRUMENTATION
CAROUSEL PUMP & LEVEL CONTROLS P&ID
8660F10 8660F1089N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
POWERSOURCE
FIELD
I/O
PMP-91100
PAU PUMP NO. 1
10HP 480VAC 3PH
VFD-91100
VFD-6
480VAC-3P
MCC70293
TSH
91100
MWH
91100
HSB
91100
STOP
HSC
91100
START
HSA
91100
LOR
PMP
91100
LCP
91100
4 06N04
HSS
91100
SPEED
VFD
91100
EIPPLC-70299
PAU_PUMP
FE-91100
LOW FLOW SWITCH
875 GPM
FE
91100
THERMAL
FSL
91100
TYP
* NF111
PAU
17 91N0180N01
STRUCTURE 80
LE-91101
HIGH HIGH AND LOW LEVEL SWITCHES
LE
91101
FLOAT
LSL
91101
2 FT
LSHH
91101
7 FT
TYP
* NL100
CB
91100
TM480VAC-3PMCC70293
PlotDate:12-JUL-202311:50:22AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
KIK
BAL
91N01
167
INSTRUMENTATION
PAU PUMP STATION P&ID
8660F10 8660F1091N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PMP-99411
RECYCLED WATER PUMP #1
75HP 480VAC 3PH
1 06N01
HSA
99411
LOR
HSC
99411
START
HSB
99411
STOP
HSS
99411
SPEED
PI-99411
PRESSURE INDICATOR
0-150 PSIG
PI
99411
PRESSURE
FE-99411
THERMAL LOW FLOW SWITCH
450 GPM
FE
99411
THERMAL
FSL
99411
DISC
99411
TSH
99411
MWH
LCP 99411
99411
PMP
99411
LE-99405
LEVEL TRANSMITTER
0-25 FT
LE
99405
P-SUB
LIT
99405
TYP
* NL132
NL133
HH LEVEL 25 FT
LL LEVEL 1 FT
LE-99403
LEVEL FLOAT SWITCHES
LE
99403
FLOAT
LSLL
99403
1 FT
TYP
* NL108
LSHH
99403
25 FT
TNK
99401
RECYCLED WATER DISTRIBUTION TANK
16" RW
LSLL
99403
DIPLC-99400
L
99405
AIPLC-99400
S S
VAL-99402
TANK FILL VALVE
H
ZSC
99402
DICLOSEDPLC-99400
ZSO
99402
DIOPENEDPLC-99400
ZCO1
99402
DOOPENPLC-99400
ZCC1
99402
DOCLOSEPLC-99400
ZCO2
99402
DOOPENPLC-99400
ZCC2
99402
DOCLOSEPLC-99400
SV1
99402
VAL
99402
SV2
99402
ZSOC
99402
25 FT
1 FT
16" RW
14" RW
16" RW
TYP
* NF111
# KEY NOTES:
1. CABLE TERMINATION BOX.
1 DESICCANT
LSHH
99403
DIPLC-99400
FE-99406
FLOW METER
500-4000 GPM
12"
FE
99406
MAGNETIC
FIT
99406
CB
99406
TM120VAC-1PPCM-99400
TYP
* NF130
NF136
F
99406
AIPLC-99400
16" RW MM 12" RW
16" RW
OVERFLOW
VFD
99411
EIPPLC-99400
RECYCLED_PUMP
POWERSOURCE
FIELD
I/O
CB
99411
TM480VAC-3PSWBD-RWPS
VFD-99411
VFD-RH
480VAC-3P
SWBD-RWPS
WATER SYSTEM
PHASE 1-3 RECYCLED
1 99N01
99N02
PUMP STATION
RECYCLED WATER
2 99N01
99N02
PUMP STATION
RECYCLED WATER
TYP
* NP502
PlotDate:12-JUL-202311:47:58AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
99N01
168
INSTRUMENTATION
RECYCLED WATER PUMP STATION 1 P&ID
8660F10 8660F1099N001.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PMP-99412
RECYCLED WATER PUMP #2
75HP 480VAC 3PH
1 06N01
HSA
99412
LOR
HSC
99412
START
HSB
99412
STOP
HSS
99412
SPEED
PMP-99413
RECYCLED WATER PUMP #3
75HP 480VAC 3PH
HSA
99413
LOR
HSC
99413
START
HSB
99413
STOP
HSS
99413
SPEED
PMP-99414
RECYCLED WATER PUMP #4
75HP 480VAC 3PH
HSA
99414
LOR
HSC
99414
START
HSB
99414
STOP
HSS
99414
SPEED
PI-99412
PRESSURE INDICATOR
0-150 PSI
PI
99412
PRESSURE
FE-99412
THERMAL FLOW SWITCH
450 GPM
FE
99412
THERMAL
FSL
99412
PI-99413
PRESSURE INDICATOR
0-150 PSI
PI
99413
PRESSURE
FE1-99413
THERMAL FLOW SWITCH
450 GPM
FE1
99413
THERMAL
FSL
99413
PI-99414
PRESSURE INDICATOR
0-150 PSI
PI
99414
PRESSURE
FE-99414
THERMAL FLOW SWITCH
450 GPM
FE
99414
THERMAL
FSL
99414
DISC
99412
DISC
99413
DISC
99414
MWH
99412
TSH
99412
LCP
99412
PMP
99412
MWH
99413
TSH
99413
LCP
99413
PMP
99413
MWH
99414
TSH
99414
LCP
99414
PMP
99414
16" RW 16" RW
16" RW
14" RW 14" RW 14" RW
1 06N01
1 06N01
TYP
* NF111
TYP
* NF111
TYP
* NF111
CB
99412
TM480VAC-3PSWBD-RWPS
VFD
99412
EIPPLC-99400
RECYCLED_PUMP
VFD
99413
EIPPLC-99400
RECYCLED_PUMP
VFD
99414
EIPPLC-99400
RECYCLED_PUMP
CB
99413
TM480VAC-3PSWBD-RWPS
CB
99414
TM480VAC-3PSWBD-RWPS
VFD-99412
VFD-RH
480VAC-3P
SWBD-RWPS
VFD-99413
VFD-RH
480VAC-3P
SWBD-RWPS
VFD-99414
VFD-RH
480VAC-3P
SWBD-RWPS
1 99N01
99N02
PUMP STATION
RECYCLED WATER
2 99N01
99N02
PUMP STATION
RECYCLED WATER
3 99N02
99N03
PUMP STATION
RECYCLED WATER
4 99N02
99N03
PUMP STATION
RECYCLED WATER
TYP
* NP502
TYP
* NP502
TYP
* NP502
POWERSOURCE
FIELD
I/O
PlotDate:12-JUL-202311:48:07AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
99N02
169
INSTRUMENTATION
RECYCLED WATER PUMP STATION 2 P&ID
8660F10 8660F1099N002.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
PMP-99415
RECYCLED WATER PUMP #5
75HP 480VAC 3PH
1 06N01
HSA
99415
F LOR
HSC
99415
F START
HSB
99415
F STOP
HSS
99415
F SPEED
PE-99415
PRESSURE SWITCH LOW
75 PSIG OPEN
PI-99415
PRESSURE INDICATOR
0-150 PSIG
PI
99415
F
PE
99415
F PRESS SW
PSH
99415
F
FE-99415
THERMAL FLOW SWITCH
450 GPM
FE
99415
F THERMAL
FSL
99415
F
DISC
99415
F
4 99N02
99N03
PUMP STATION
RECYCLED WATER
3 99N02
99N03
PUMP STATION
RECYCLED WATER
MM
FE2-99431
FLOW METER
400-4000 GPM
16"
FE2
99431
MAGNETIC
FIT
99431
CB
99431
TM120VAC-1PPCM-99400
SYSTEM
DISTRIBUTION
MWH
99415
F
TSH
99415
F
LCP
99415
F PMP
99415
F
F
99431
AIPLC-99400
16" RW
TYP
* NF130
NF136
PE-99432
PRESSURE TRANSMITTER
0-300 PSIG
PI-99432
PRESSURE INDICATOR
0-300 PSI
PI
99432
PRESSURE
PE
99432
PRESSURE
PIT
99432
TYP
* NP501
P
99432
AIPLC-99400
TNK
99432
VFD
99415
EIPPLC-99400
F
RECYCLED_PUMP
CB
99415
TM480VAC-3PSWBD-RWPS
F
VFD-99415
VFD-RH
480VAC-3P
SWBD-RWPS
F
FUTURE
POWERSOURCE
FIELD
I/O
16" RW
PlotDate:12-JUL-202311:48:12AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
99N03
170
INSTRUMENTATION
RECYCLED WATER PUMP STATION 3 P&ID
8660F10 8660F1099N003.dwg
jwicks
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
BRETT A. LEE
SEALED BY
ORIGINAL
**
CA PE NO. 22911
CP-99400
PLC-99400
PCM-99400
PCM CABINET
PCM-99400
CB2
99400
TM120VAC-1PPNL-RWPS-L
CB1
99400
TM120VAC-1PPNL-RWPS-L
SPD-99400
PCM SURGE PROTECTOR
TSH
99400
DIPLC TEMPPLC-99400
JS3
99400
DIREDUNDANCY OKPLC-99400
JS2
99400
DIPWR SUP OKPLC-99400
JS1
99400
DIPWR SUP OKPLC-99400
ZS1
99400
DIINTRUSIONPLC-99400
XA6
99400
DISPD FAILPLC-99400
PCM
99400
SPD
99400
TSH
99400
ZS1
99400
INTRUSION DR
2 06N02
SPD2-99400
PCM SURGE PROTECTOR
XA4
99400
DISPD2 FAILPLC-99400
XA5
99400
DIES-P FAILPLC-99400
XA7
99400
DIECP-P FAILPLC-99400
SPD2
99400
XA5
99400
XA7
99400
JS4
99400
DIACB OKPLC-99400
POWERSOURCE
FIELD
I/O
PQM-99400
RECYCLED WATER PUMP STATION
PQM
99400
PQM
99400
EIPPCM-9940
POWER_QUALITY_METER
PlotDate:12-JUL-202311:48:20AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
DB
AAW
BAL
99N04
171
INSTRUMENTATION
RECYCLED WATER PUMP STATION
PCM-99400 CABINET P&ID
8660F10 8660F1099N004.dwg
jwicks
3 '-6"
1/2"
6"MIN
1" MIN
1/2"
6"MIN
1/2"
1/2"
1/2"
1/2"
8"
1"
5"
1 1/2"
1'-2"
6"
2"
2"
RUNGSEQUALLYSPACED@12"OCMAX
30" MAX24" MIN
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
MATTHEW C. KALLEVANT
SEALED BY
ORIGINAL
**
CA PE NO. 84405
3. PROVIDE CLOSURE FLANGE AT EXTERIOR WALL. SET FLANGE IN SEALANT. 3. LOCATE INVERT OF SCUPPER 2" ABOVE ADJACENT ROOF DRAIN INLET.
COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.
BE KYNAR. COLOR SHALL BE ENGINEER SELECTED FROM STANDARD COLOR OFFERINGS.
2. FABRICATE SCUPPER AND FLANGE FROM MIN 0.032" THICK PRE-FINISHED AL. FINISH SHALL OTHERWISE RECOMMENDED BY ROOFING MANUFACTURER.
1. PROVIDE SCUPPER AS DETAILED AND ADHERE TO SURROUNDING STRUCTURE UNLESS NOTES:
AC310
06/21/19
TYP
AC300
ROOF
IN MASONRY CONSTRUCTIONGROUT CELL AT ANCHORS
1/4
TYP
3"8"
3"
8"
91/2"
SPACINGMAX WITH EQUALRUNGS @ 12" OC
*
*
TYP
WITHEXCEPT AS NOTEDALUMINUM LADDER
WATERTIGHT ROOF MEMBRANE.SEAL ALL AROUND AND MAINTAINFLASHING AT LADDER SUPPORT.
RUNGSEQUALLYSPACED(12"OCMAX)
NOTE 1
3"
(MASONRY SIMILAR.)CONCRETE WALL.
TREAD PLATE) AND 1" VERT EDGE ONSURFACE TO T.O. COPING,1" GAP (T.O. WALKING SIDE 3/16EATYP
2"
WELD AS NOTEDOVER LADDER RAIL ANDWITHOUT GATE. SLOT PIPEALUMINUM PIPE RAILPROVIDE SEMI-CIRCULAR RAILSAND WELD ENDS TO LADDERPERIMETER EDGES DOWN 1"3/8" AL TREAD PL. BEND 4
LADDER - ALUMINUM - PARAPET
3. INSTALL FALL PREVENTION SYSTEM WHERE HEIGHT OF LADDER EXCEEDS 24'-0".
TO CONCRETE WITH 1/2"Ø SST CONCRETE ANCHOR EACH SIDE. MIN 4" EMBED.
2. ABOVE CONCRETE SLAB, EXTEND RAILS DOWN. SET ON MIN 1" NON-SHRINK GROUT. FASTEN 1. WHERE NOT ABOVE CONCRETE SLAB, TERMINATE SIDE RAILS AS SHOWN.NOTES:
METAL COPING AND
REGLET ANDCOUNTERFLASHING
BASE FLASHING
WALL MATERIAL ASINDICATED ON THEDRAWINGS
SLOPE TOP OF WALL
PREFABRICATED
COUNTERFLASHINGREGLET &
BASE FLASHING
EXTEND BASE FLASHING UP UNDERCOPING UNLESSREGLET ANDCOUNTERFLASHINGARE INDICATED ONTHE DRAWINGS.
PREFABRICATED METAL
BASE FLASHING
ANCHOR PLATE
COPING AND ANCHORPLATE
06/21/19
TYP
AG220 PARAPET DETAILS
A- B- D- C- METAL COPING STUCCO FINISH PREFABRICATED W/ REGLET MASONRY WALL W/ METAL COPING CONCRETE WALL W/ REGLET ~ ~
~
8" MIN TO
TOP OF ROOF
8" MIN TO
TOP OF ROOF
8" MIN TO
TOP OF ROOF
TERMINATION BAR
1/2"
1/2"
TERMINATION BAR
@ 4'-0" OCx 10" EMBEDMENT AB3 x PRESSURE TREATED
TREATED TOP PLATEDOUBLE 2 x PRESSURE
SCUPPER
PACK W/ NONFLANGE CLOSURE
BUILT-UP
3" CANTSTRIP
ROOF
CLOSUREFLANGE
SCUPPER
SINGLE PLY
SHRINK GROUT
SHRINK GROUTPACK W/ NONCANT STRIP
ROOFING
06/21/19
TYP
AG222
B- SECTIOND- SECTION
E- CLOSURE FLANGE
C- ISOMETRIC - SINGLE PLY ROOFINGA- ISOMETRIC - BUILT-UP ROOFING E-E- 51/2"
ASREQUIRED
11/2"
4"
10"
4"
4"
3"
4" 3"
ASREQUIRED
51/2"4"
10"
4"
4"
11/2"
4"
1"
11/2"(TYP)
SCUPPER - SECONDARYBUILT-UP AND SINGLE-PLY SYSTEMS
06/21/19
AG223
TYP
E- CLOSURE FLANGE
C- ISOMETRIC - SINGLE PLY ROOFING
D- SECTION
A- ISOMETRIC - BUILT-UP ROOFING
B- SECTION
E-E- ASREQUIRED 51/2"4" 10" 4"4" 3"3" 4"ASREQUIRED
51/2"4"
10"
4"
4"
1"
11/2"(TYP)
SCUPPER
CLOSUREFLANGE
PACK W/ NONSHRINK GROUT SINGLE PLY
ROOF
SCUPPER
FLANGECLOSURE
SHRINK GROUTPACK W/ NONBUILT-UP ROOFING
3" CANTSTRIP
CANTSTRIP
3. PROVIDE CLOSURE FLANGE AT EXTERIOR WALL. SET FLANGE IN SEALANT.
COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.
BE KYNAR. COLOR SHALL BE ENGINEER SELECTED FROM STANDARD COLOR OFFERINGS.
2. FABRICATE SCUPPER AND FLANGE FROM MIN 0.032" THICK PRE-FINISHED AL. FINISH SHALL OTHERWISE RECOMMENDED BY ROOFING MANUFACTURER.
1. PROVIDE SCUPPER AS DETAILED AND ADHERE TO SURROUNDING STRUCTURE UNLESS NOTES:
SCUPPER - PRIMARYBUILT-UP AND SINGLE-PLY SYSTEMS
DRAWINGSON THEINDICATEDWALL AS
ROOF DRAIN
SCUPPER
DOWNSPOUT
CONDUCTORHEAD
06/21/19
TYP
AG225
A- B- ELEVATION SECTION
B- WITH ROOFING TYPE. 3. SEE SPEC FOR SPECIFIC ROOFING AND INSULATION MATERIAL. SCUPPER SHAPE WILL VARY AL IN CONTACT WITH CONC OR CMU AS SPECIFIED. SEAL ALL JOINTS. KYNAR. COLOR SHALL BE ENGINEER SELECTED FROM STANDARD COLOR OFFERINGS. COAT 2. FABRICATE CONDUCTOR HEAD FROM MIN 0.032" THICK PRE-FINISHED AL. FINISH SHALL BE MANUFACTURER. 1. PROVIDE CONDUCTOR HEAD AS DETAILED UNLESS OTHERWISE RECOMMENDED BY ROOFING NOTES:
CONDUCTOR HEAD - ALUMINUM
DOWNSPOUT HANGER1 1/2" x 0.062 AL @ 4'-0" OC
CONC ANCHORS @
INDICATED ON THE WALL MATERIAL AS
CONC OR MASONRYWALLS (TYP)
SPLASH BLOCKWHERE REQD
3" x 4" DOWNSPOUTFORMED FROM 0.032
06/21/19
TYP
AG227
A- A- SECTION
DRAWINGS
PRE-FINISHED AL UNLESS OTHERWISE INDICATED ON THE DRAWINGS.SELECTED FROM STANDARD COLOR OFFERINGS.COLOR SHALL BE ENGINEER
3. COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.2. ALTERNATE SIZE DOWNSPOUTS WILL BE REQUIRED, IF SO INDICATED ON THE DRAWINGS. 1. PROVIDE SPLASH BLOCK AS SHOWN EXCEPT AT PAVING AND SIDEWALKS.NOTE:
DOWN SPOUT - ALUMINUM
2 - 1/4"Ø SST
4" FELT CAP FLASHING. SET INFLASHING CEMENT AND COVER W/ 1/8" THICK FLASHING CEMENT.
BASE FLASHINGSET IN ASPHALT
BACKER FELT SET IN ASPHALT
ROOFING FELTS
3" CANT STRIP
TAPERED INSULATION ROOF CRICKETWHERE INDICATED ON THE DRAWINGS RIGID INSULATION.THICKNESS AS SPECIFIED.
SEE DRAWINGS FOR ROOFDECK AND ROOF FRAMING
SCREW TYPESIZE AND SPACINGPER MANUFACTURERSRECOMMENDATION.MECH FASTENERS.
WALL MATERIAL AS INDICATED
08/01/05
TYP
AG140
~
~
~ ~
~
~
~
~
~
5"MIN3"
ON THE DRAWINGS
TYP
AG220 METAL COPING
THE DRAWINGSAS INDICATED ONCOUNTERFLASHINGOR REGLET AND
ROOF SYSTEM - BUILT-UP - DETAIL
TYP
AG227
TYP
AG223
TYP
AG229
TYP
AC300
S 12/28/20
A- SECTION
WELDING (TYP)GRIND SMOOTH AFTERRADIUS OF GUARDRAIL POST,BEND BAR SIDE RAILS TO
LANDING LEVELTOP RUNG AT
1/2" RADIUS
SIDE RAILS1/2 x 4AL RECT1/8" RADIUSSMOOTH TOCORNERSROUND ALL 1/4
TYP
1/41/4
1'-4"
8"
4"
TYP
ANCHORSTRAPS.
SPACE@6'-0"OCMAX.
1'-6"
3'-6"
OTHERWISE INDICATED)GATE (TYP UNLESS
ELEVATION
RAILS AND PLUG WELD. (TYP)EXTEND HALF WAY THROUGHTREAD ON TOP SURFACE.AL 1" SQ SOLID RUNGS W/
DRAWINGSINDICATED IN THE GUARDRAIL, TYPE AS
GROUTMINIMUM 1" NON-SHRINK
DWGSWALL, SEEMASONRYCONC OR
LADDER - ALUMINUM - WALL
MASONRY CONSTRUCTION. (TYP)ANCHOR INTO GROUTED CELL ATWALL W/ 5/8"Ø SST CONC ANCHORS.WELD TO LADDER AND FASTEN TOAL RECT 3/8 x 3 ANCHOR STRAP. 5/8"Ø SST CONC ANCHORSFASTEN TO FLOOR W/
4. WHERE GUARDRAIL IS SST, BOLT PIPE TO RAIL W/ 2 - 1/2"Ø SST BOLTS.
SLEEVES AND WASHERS AT DISSIMILAR METALS, AS SPECIFIED.
3. COAT ALL AL SURFACES IN CONTACT W/ CONC AND MASONRY, AND INSTALL ISOLATION (2'-3" AT SMOOTH WALL). 1'-3" EACH SIDE OF CENTER LINE, ON EACH SIDE OF LADDER.
2. MINIMUM CLEARANCE TO ANY OBSTRUCTION ADJACENT TO LADDER: 2'-6" ON CLIMBING SIDE 1. INSTALL FALL PREVENTION SYSTEM PER SPEC WHERE HEIGHT OF LADDER EXCEEDS 24'-0".NOTES: -A PlotDate:12-JUL-202312:20:29PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
TYPICALS
TYPICAL DETAILS
8660F10
eparker
00TA01
8660F1000TA01.dgn
ARCHITECTURAL
JKN
172
WIDTH
FRAME
3'-0"FR
AMEHEIGHT
4"
2"
5'-06" TYP "
3'-8"
MAX
3'-0"
6" 2"
53/4"
5'-0"MAX5'-0"MAX
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
MATTHEW C. KALLEVANT
SEALED BY
ORIGINAL
**
CA PE NO. 84405
~
AJ100
06/21/19
TYP
REMOVABLE TRANSOM BAR
GLASS SIDELIGHT
R S T
~
~
LOCATIONS REQUIRED. (TYP)HARDWARE SCHEDULE FORFRAME TYPE. SEE DOOR AND BE TINTED INSULATING GLASS.
4. GLASS AT INTERIOR SIDELIGHTS SHALL BE CLEAR. GLASS AT EXTERIOR SIDELIGHTS SHALL
3. GLASS AT SIDELIGHTS SHALL BE TEMPERED.
LOCATION.
2. SIDELIGHT MAY BE ON EITHER SIDE OF DOOR. SEE DRAWINGS FOR REQUIRED SIDELIGHT
1. SEE DOOR AND HARDWARE SCHEDULE FOR FRAME SIZE, MATERIAL, AND DETAILS.
NOTES:
(TYP)
DOOR - FRAME - STICK AJ103
06/21/19
TYP
PANEL ONLYTRANSOMREMOVABLE
COILING METAL DOOR
F G N V D
A
C T
(TYP)
6"
6" MIN
6"
6"
10" SQ
10"
10"
2"
~
~
~
~
~
~ ~
GLASS
GLASS
GLASS
GLASS
SHELFDOOR WITHDUTCH
LOCATIONS REQUIRED. (TYP)HARDWARE SCHEDULE FORDOOR TYPE. SEE DOOR AND
ALUM FRAME
~
NOTE 5SEELOUVER.
SCHEDULE.AND HARDWARENOTED ON DOORTRANSOM ASDOOR TYPE BELOW NOTES:1. DOOR SIZE AND TYPE SHALL BE IN ACCORDANCE WITH DOOR AND HARDWARE SCHEDULE.2. GLASS AT DOORS SHALL BE TEMPERED UNLESS OTHERWISE INDICATED ON THE DRAWINGS.3. GLASS AT INTERIOR DOORS SHALL BE CLEAR. GLASS AT EXTERIOR DOORS SHALL BE TINTED.4. PROVIDE WIRE GLASS AT LABELED DOORS.5. LOUVER MAY BE REQD AT ANY DOOR TYPE. IF A LOUVER IS REQUIRED, SIZES AND LOCATIONS WILL BE NOTED ON DOOR AND HARDWARE SCHEDULE.6. PROVIDE LABELED DOORS IN ACCORDANCE WITH DOOR AND HARDWARE SCHEDULE.
DOOR - ELEVATIONS - TYPES
A- METAL FRAMING B- WOOD FRAMING
C- D- MASONRY CONCRETE
AJ105
06/21/19
TYP
3/4"
3/4"
1/2" MIN
~ ~
CAULK BOTH SIDES
FILL WITH GROUT
CAULK BOTH SIDES
FILL WITH GROUT
HEADER. 2 - 2x MIN.
DOOR FRAME DOOR FRAME
DOOR FRAME DOOR FRAME
WALLTHICKER LINE OF
DOOR DOOR
TO JAMB.DOWN AND FASTEN CLIP LEGS, BEND METAL TRACK.
SHEET 1 OF 2
GYPSUM BOARD GYPSUM BOARD
DOOR - HEAD - DETAILS
A- B- C- MASONRY METAL FRAMING WOOD FRAMING
AJ107
06/21/19
TYP
GYPSUM BOARD GYPSUM BOARD
JAMB ANCHOR
PER JAMBTWO STUDS
CAULK BOTH SIDES
~
~
SHEET 1 OF 2
5/8" 1 15/16"
5/8" 1 15/16"
3/4"
5/8"
1 15/16"
~~
FILL WITH GROUT
DOOR FRAME
DOOR FRAME
(TYP)
DOOR
DOOR FRAME
D- CONCRETE
PIPE SPACER
CAULK BOTH SIDES
~
FILL WITH GROUT
LINE OF THICKER WALL
3/4"
1 15/16"
5/8"
DOOR FRAME
DOOR
ANCHOR
(COUNTERSUNK NOTE2)
LINE OF THICKER WALL
DOOR - JAMB - DETAILS
A- B- C- D- E- AJ109
06/21/19
TYP
CARPET BARRESILIENT
CARPET
STRIP AS REQ'DRESILIENT REDUCER
CONCRETE CERAMIC TILE
PAD AT EXTERIOR.CONC SIDEWALK OR ENTRANCECONT CONC SLAB AT INTERIOR.
WITH ROOM FINISH SCHEDULEFINISH FLOOR MATERIAL IN ACCORDANCE
FINISH SCHEDULEWITH ROOMIN ACCORDANCEOR SHEET VINYLRESILIENT TILE
ROOM FINISH SCHEDULEIN ACCORDANCE WITHFINISH FLOOR MATERIAL
SCHEDULEFINISHWITH ROOMACCORDANCEMATERIAL INFINISH FLOORCONTINUOUS
1. DOOR CLEARANCE AT BOTTOM OF DOOR SHALL BE 1/4" MIN AND 3/8" MAX.
NOTE:
SET THRESHOLD IN SEALANT.HARDWARE SCHEDULE.ACCORDANCE WITH DOOR ANDTHRESHOLD AND DOOR BOTTOM IN
DOOR - SILL - DETAILS
2" 2"
2"
1"
1'-2" 4"
2'-0"
51/2"
2"
4"
06/21/19
AG229
TYP
2" 2"
2"
1"
1'-2" 4"
2'-0"
51/2"
2"
4"
SPLASH BLOCK - CONCRETE - SURFACE MOUNTED
FIRE EXTINGUISHER.SEE SPECIFICATIONSFOR SIZE AND TYPE.
FINISH FLOORELEVATION
WALL
FIRE EXTINGUISHER.SEE SPECIFICATIONSFOR SIZE AND TYPE.
FINISH FLOORELEVATION
WALL
2. SEE SPECIFICATIONS FOR SIGNAGE REQUIREMENTS ABOVE FIRE EXTINGUISHERS.
PARTITION WALL.GROUTED CELL. MOUNT TO STUD WITH LAG BOLTS, OR WOOD SCREWS FOR WOOD CONCRETE ANCHORS FOR MASONRY OR CONCRETE WALLS. AT MASONRY INSTALL AT
1. MOUNT TO WALL WITH NUMBER AND SIZE OF ANCHORS TO MATCH BRACKET. USE NOTES:
AN400
TYP
06/21/19
FIRE EXTINGUISHERWALL-MOUNTED
PlotDate:12-JUL-202312:23:57PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
TYPICALS
TYPICAL DETAILS
8660F10
eparker
00TA02
8660F1000TA02.dgn
ARCHITECTURAL
JKN
173
OD OF MANHOLE + 12"
10"
3" MIN
3'-6"
1"
1"
SEE DRAWINGS (4'-0" MIN)
PAD LENGTH
SEEDRAWINGS(6'-0"MIN)
PADWIDTH
MIN
1'-4"
MIN
12"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/10/2023
BRIAN W. AVON
SEALED BY
ORIGINAL
**
CA PE NO. 76832
SEE DWGSFIN FL
(TYP)1/4" RADIUS
JOINT SEALANTSIDEWALK/PAVEMENT
1/4" MIN"W" /2
GAPMAX 3/8"MIN 1/4"
BACKER ROD
JOINT MATERIALRUBBER EXPANSIONSYNTHETIC SPONGE
CUT OUT TOP OF RCPOR VCP WITHIN MANHOLE3" EPOXY GROUTSEE NOTE 2 (TYP) CLASS "A"
48" FOR 6" THRU 12"
PIPES.
60" FOR 15" THRU 48"
PIPES.
#5 @ 12" EW
STEEL TROWELFINISH
SOIL BACKFILLEXISTING PAVEMENTTOP OF MH SHALL MATCHAC PAVEMENT OR
CONCRETE
INDICATED ON THEUNLESS OTHERWISE
MORTAR 6" TO EXISTING GRADE
DRAWINGS
BASE WHERE SOIL ISOR 8" MIN ABC UNDERUNDISTURBED SOILCAST BASE AGAINSTUNSTABLE.CAST-IN-PLACECONE SHOWN ROTATED 90°.
TYP
N
8" (TYP)
12" MIN
6" MIN. 1'-6" MAX.
6" CLR
CS110 MANHOLE
30" CI MH FRAME AND COVER.
~
3" MIN
ASREQD
CLASS "A" CONCRETE BASE.PRECAST CONCRETE MANHOLEECCENTRIC PRECAST CONCRETEGRADE RINGS AS REQUIRED 2'-6"TO3'-0"
RISERS WITH VARIABLE HEIGHT
MANUFACTURER'S DETAIL.
3. FORM GROOVE IN MANHOLE BASE WITH STEEL OR ALUMINUM BASERING PER
2. SEAL JOINTS WITH PRECAST CONCRETE JOINT SEALANT.
GROUT.
1. LOCATE MANHOLE COVER ON DOWNSTREAM SIDE OF MANHOLE. SET MANHOLE FRAME IN NOTES:
SEE NOTE 3SEE NOTE 1.
12/24/2020
SEE DWGSFINISHED GRADE.PAVEMENT OR
(7" MAX)ON DWGSSHOWNOTHERWISE4" UNLESS
PVC PIPE SLEEVECLASS "C" CONCRETE4"Ø GALV SCH 40 STEEL POST. 4'-0"
6"
MATERIAL ALL
CONCRETE PAVEMENT
SEE DRAWINGS.
CONCRETE PAVEMENT
WELD ON CAP
PAINT SAFETY YELLOW PERANSI Z535.1. 1/2" BITUMINOUS
FIBER EXP JOINTAROUND (UNLESSOTHERWISE INDICATEDON THE DRAWINGS)
FINISHED GRADEAC PAVEMENT OR
FINISHED GRADEOR AC PAVEMENT.
TYP
N
CF161 -B -B -A
12/29/2020
GUARD POST - REMOVABLE
1/4" RADIUS
CR314
TYP - SECTION - ~ TYP EACH SIDE #4@12" EW #4 x FIN FL UNO FLUSH W/ T.O. PAD SIDEWALK - ENTRANCE PAD OF DOOR SLOPE 1/4"/FTUNO (TYP 3 SIDES)THICKENED EDGE
B
A PLAN
B
(TYP ALL EDGES)
6" 8"
MIN (TYP)
EXT DOOR
THRESHOLD
SEE NOTE 1.EXPANSION JOINT.
EMBED.S194/TYP MIN 4" SET PER DETAIL SMOOTH DOWELS. 304 SST OILED 1/2" DIA x 1'-8TYPE ABC (TYP)COMPACTED MIN 6"
1. EXPANSION JOINT AT FACE OF STRUCTURE: 3/8" WIDE AND AS INDICATED IN DETAIL 1.NOTES: -1 DETAIL 12/24/2020
CR314
TYP
SIDEWALK - ENTRANCE PAD
12/24/2020
AT CONCPAVEMENT
6" 0"
3" CLRMIN
MIN
2"CLR
PlotDate:12-JUL-202312:20:32PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
TYPICALS
TYPICAL DETAILS
8660F10
00TC01
eparker
CIVIL
8660F1000TC01.dgn
JM
174
6 "MIN12"12"
PREFORMED CHANNEL
WALLS AND LINTELS.DRAWINGS FOR REINFORCEMENT IN CMU WALL. REFER TO STRUCTURAL (TYP)WEIGHTS UNDER 200 LBS. U.O.N. 5/8" Ø WITH 3" OF EMBEDMENT FOR Z FITTING W/ CMU ANCHOR FOR CMU,
AS REQUIRED (TYP)ANCHORS, NUTS, AND LOCKWASHER
FITTINGS AT 2'-8" O.C. MAXPROVIDE INTERMEDIATE ZWHERE LENGTH EXCEEDS 2'-8" 18"
DECK - SEE STRUCTURAL
CROSSING)(TYP EACH SIDE EACH BEAMBEAM CLAMP W/SQ U-BOLT
PREFORMED CHANNEL
STEEL BEAM
3/4" RIGID CONDUIT
GUSSET FOR LUMINAIRE
BEAM CLAMP WITH
(SIDE VIEW)
STEEL BEAM
CONDUIT HANGERBEAM CLAMP WITH
6" MIN 6" MIN
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
GROUND ROD
TYP COMPRESSION CONNECTION
EG002
S
DIAMETER AS SPECIFIED)
GROUND ROD (LENGTH AND
GRADE
FINISHED
1 1
KEY NOTES:
CABLE PER CONNECTOR MANUFACTURERS GUIDELINES.
GROUND ROD TO GROUND GRID CROSS CONNECTOR. SIZE FOR ROD AND OR IN SPECIFICATIONS.
SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
3'-0" (MIN) SOIL
FINISHED GRADE
DIAMETER AS SPECIFIED)
GROUND ROD (LENGTH AND
BACKFILL
SOIL
1 1
KEY NOTES:
DRAIN ROCK
OR IN SPECIFICATIONS.
SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR
AND CABLE PER CONNECTOR MANUFACTURERS GUIDELINES.
GROUND ROD TO GROUND GRID CROSS CONNECTOR. SIZE FOR ROD
GROUND WELL AS SPECIFIED
EG001 GROUND ROD AND GROUNDWELL
TYP COMPRESSION CONNECTION
S
GENERAL NOTES:
CONCRETE ANCHORS SHALL BE PER THE SPECIFICATIONS.
2. SUPPORTS TO BE SPACED IN ACCORDANCE WITH NEC REQUIREMENTS. 1. THIS DETAIL TYPICAL FOR BOTH VERTICAL AND HORIZONTAL MOUNTING.
GRADE
FINISHED
1 1
OR IN SPECIFICATIONS.
SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
3'-0" (MIN)
SOIL
MANUFACTURERS GUIDELINES.
GROUND GRID CROSS CONNECTOR. SIZE FOR CABLE PER CONNECTOR KEY NOTES:
EG101
TYP
S
COMPRESSION CONNECTIONCOPPER GROUNDING CABLE CONNECTION SKID
GROUND BUS OR EQUIPMENT
CONNECT TO EQUIPMENT
HOUSEKEEPING PAD
FLOOR OR
GROUNDING PLATE
KEY NOTES:
1 1
PLACEMENT OF CONCRETE.
INTO GROUND PLATE PRIOR TO
THREAD A POSITIONING ROD
SPECIFICATIONS.
DRAWINGS OR IN
SIZE AS INDICATED ON THE
GROUND GRID CONDUCTOR.
SPECIFICATIONS.
DRAWINGS OR IN
SIZE AS INDICATED ON THE
GROUND GRID CONDUCTOR.
EG102
TYP
S
COMPRESSION CONNECTIONCAST GROUNDING PLATE
DUXSEAL
FILL WITH
GRADE
FLOOR SLAB OR
COLUMN, ETC.
SKID, POST, STEEL BLDG.
METALLIC EQUIPMENT
CLAMP TO SKID
1-1/2" MINERALLAC
HEAVY DUTY COMPRESSION TERMINAL.
KEY NOTES:
1 1
NOTES:
SLEEVESCHEDULE 80
1-1/2" PVC
SPECIFICATIONS.SIZE AS INDICATED ON DRAWINGS OR IN
GROUND GRID CONDUCTOR.
STRUCTURE, NOT TO EQUIPMENT OR TANK SHELLS.
2. NOTE: BOLT GROUND LUG ONLY TO EQUIPMENT SKIDS OR
BOLTING ON THE GROUND LUG.
1. CLEAN ALL PAINTED SURFACES TO BARE METAL BEFORE
EG201 EQUIPMENT SKID GROUNDING
TYP COMPRESSION CONNECTION
S
ASREQUIRED
PREFORMED CHANNEL ATTACHMENTTO FULLY GROUTED CMU WALL
EA080
TYP
S
TYP
S
EA060
GRATING SUPPORTSATTACHMENT TO ALUMINUM
3/16 1/23/16 1/2
4" MAX2" MIN
FLANGE
BEAM
EDGE OF
FLANGEPL TO BEAMTYP EA CLAMP
ACROSS
ALONG
ATTACHMENT TO STEEL BEAMS
S
TYP
EA030
AL CHANNEL
PREFORMED
CHANNEL
SUPPORT
AL GRATING
CHANNEL
SUPPORT
AL GRATING
CLAMP (TYP EA END)
STEEL U-BOLT W/TOP SQUARE STAINLESS
AL GRATING
PlotDate:12-JUL-202312:20:29PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CE
TYPICALS
TYPICAL DETAILS
8660F10
CE
JGB
00TE01
175
8660F1000TE01.dgn
ELECTRICAL
eparker
GROUT
NON-SHRINK
REQUIREMENTS.
POLE MANUFACTURERS
LEVELING NUTS PER
LOCK WASHERS, AND
SST ANCHOR BOLTS, NUTS,
REQUIREMENTS.NUTS PER POLE MANUFACTURERSLOCK WASHERS, AND LEVELINGSST ANCHOR BOLTS, NUTS, WALL
OR SPECIFICATIONS)(SIZE AS INDICATED ON DRAWINGSGROUND GRID CONDUCTOR
FOOTING
CONCRETE.20'-0" LENGTH ENCASED IN#4 SDBC (MIN) WITH MIN
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
GROUT
NON-SHRINK
BACK
BOLT
PANEL
WASHER
& USE A STAR
SCRAPE PAINT
GROUND CONNECTION
THREADS TO ALLOW A
REMOVE PAINT FROM USE A WIRE BRUSH TO
THE ENCLOSURE
BACK WALL OF
PANEL TO THE
OF THE BACK
STUD MOUNTING
BACK PANEL
CHASSIS TO THE
BUS OR A
OF A GROUND
BOLT MOUNTING
WASHER
FLAT
HOLE
TAPPED
STUD
WELDED
(TYP)
BRACKET
MOUNTING
GROUND BUS OR
BACK PANEL
CHASSIS TO THE
BUS OR A
OF A GROUND
STUD MOUNTING
(TYP)
WASHER
STAR
STUD
WELDED
PAINT
SCRAPE
ENCLOSURE
BACK WALL OF
BOLT
(TYP)
GROUND LUG
COMPRESSION
(INSIDE) (OUTSIDE)
ENCLOSURE WALL
CONDUCTOR (TYP)
GROUNDING
EQUIPMENT WALL
ENCLOSURE
CHASSIS TO
BUS OR A
OF A GROUND
BOLT MOUNTING
(TYP)
NUT
OR
TYP
S
EG205 ENCLOSURE GROUNDING DETAILS
C PHASEB PHASEA PHASE
TRANSFORMER
FIRST DISCONNECTING DEVICE AFTER
EQUIPMENT FRAME
INTEGRALLY BONDED TO
EQUIPMENT GROUND BUS
EQUIPMENT FRAME
GROUND PAD
TRANSFORMER
CONDUCTOR
GROUNDING ELECTRODE
TYPE BUSHINGS
GROUNDING
CONDUIT
NEUTRAL BUS
SYSTEM BONDING JUMPER
DRAWINGS
SYSTEM AS INDICATED ON THE
TO GROUNDING ELECTRODE
DRAWINGS
SYSTEM AS INDICATED ON THE
TO GROUNDING ELECTRODE
EQUIPMENT BONDING JUMPER
TYP
S
EG511 TRANSFORMER (NON-UTILITY) 3-PHASE, 4-WIRE
SECONDARY POWER GROUNDING DETAIL
CONDUIT
FLUSH MOUNTED
SUSPENDED
CONDUIT
LUMINAIRE
LUMINAIRE
HANGER
CONDUIT
HANGER
CONDUIT STRAP OR EQUAL
HANGER w/SAFETY
APPLETON FHSN
OR EQUAL
FHLF LOOP
APPLETON
OR EQUAL
AHG HANGERAPPLETON
KEY NOTES:
USE MEYERS HUB IN WET AND/OR CORROSIVE AREAS. LENGTH AS REQUIRED FOR INDICATED MOUNTING HEIGHT.
TO ATTACHMENT DETAIL
PREFORMED CHANNEL REFER
CAP END CONDUIT AS REQUIRED.
AS REQUIRED (TYP)
STUD NUT OR HANGER
LINEAR FIXTURE NUT,
TO ATTACHMENT DETAIL
PREFORMED CHANNEL REFER
ROD
CHAIN OR
1 2 2
3 TYP
S
EL200
1 2
3 LINEAR LUMINAIRE MOUNTING
TYP
ONE-PIECE POLE
HINGED POLE
TYP
S
EL502 ANCHOR BASE FOR LIGHT POLE
MOUNTED ON SLAB
TYP
S
EG304 GROUNDING CONNECTION TO
FOOTING (UFER)
1 1
GROUND BUS MOUNTING
GROUND BUS
BOLT
WASHER
STAR
HOLE
TAPPED
BUS
GROUND GROUND LUG
ELECTRODE SYSTEM
CONDUCTOR TO GROUNDING
GROUNDING ELECTRODE
CONDUCTORS
GROUNDING
EQUIPMENT
ELEVATION VIEW SIDE VIEW
GROUND LUG
COMPRESSION
TYP
S
EG204 GROUND BUS CONNECTIONS
# KEY NOTES:
BETWEEN CONDUCTOR AND FACE OF CONCRETE.PROVIDE MIN 1 1/2" CLEAR BETWEEN CONDUCTOR & REINFORCEMENT, OR
1. GROUND GRID CONDUCTOR TO BE FULLY ENCASED IN CONCRETE.
PlotDate:12-JUL-202312:20:39PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CE
TYPICALS
TYPICAL DETAILS
8660F10
CE
JGB
00TE02
176
8660F1000TE02.dgn
ELECTRICAL
eparker
(TYP
)
3.0"
(TYP)
3.0"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
8660F.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
JULY 2023 OF 200
CITY OF UKIAH
RECYCLED WATER PROJECT - PHASE 4
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
CONFORMED DOCUMENTS
**
4/7/2023
ERIK M. BAHNEMAN
SEALED BY
ORIGINAL
**
CA PE NO. 19683
54321
GROUND WIRESDBC
CONCRETE (RED)CLASS CE
FINISHED GRADE
12"
24"
BELOW
GRADE (MIN)"
CURING.
3. MAKE PROVISIONS TO PREVENT CONDUIT FLOTATION DURING CONCRETE PLACEMENT & CONDUITS.
REFER TO DUCT BANK SECTIONS, AND CONDUIT SCHEDULE FOR NUMBER AND SIZE OF SPECIFICATION TO ACCOMMODATE ACTUAL NUMBER OF CONDUITS WITHIN DUCT BANK.
2. ADJUST SIZE OF DUCT BANK BASED UPON THESE GUIDELINES AND THE DUCT BANK
1. DIMENSIONS SHOWN ARE MINIMUM.
NOTES:
678
OTHERWISE INDICATED ON THE DRAWINGS.
#4/0 SDBC GROUND WIRE UNLESS
THE DUCT BANK.
BOND THE DUCT BANK GROUND WIRE TO THE GROUNDING SYSTEM AT BOTH ENDS OF VERTICAL LEGS EACH SIDE.
LOWER PORTION OF TIES COULD BE U-BARS IF UPPER PORTIONS PROVIDES 1'-4" CONTRACTOR'S OPTION TO PROVIDE 1'-4" LAP LENGTH EACH SIDE OF HORIZONTAL TIE.1'-4" OR 135 DEGREE HOOK FOR SHALLOW DUCT BANKS SHALLOWER THAN 21"REFER TO DUCT BANK SECTIONS AND SPECIFICATIONS FOR CONDUIT REQUIREMENTS.PVC CONDUIT SPACERS ON 8'-0" CENTERS (MAXIMUM). LOCATE 12" FROM TIES.
SUPPORTS AT INTERVALS OF 24" TO REDUCE DEFLECTION.
PVC CONDUIT SPACER ALONG LENGTH OF DUCT BANK. PROVIDE PRECAST BAR MINIMUM OF TWO PRECAST CONCRETE BAR SUPPORTS PLACED UNDER A TIE AT EACH #4 REINFORCING STEEL TIES MAXIMUM 24" ON CENTER ALONG LENGTH OF DUCT BANK.
BANK.
#4 REINFORCING STEEL 12" MAXIMUM ON CENTER AROUND ENTIRE PERIMETER OF DUCT KEY NOTES:
9 S
EM001 REINFORCED CONCRETE DUCT BANK
1 4
2 3
2 4
5 TYP
1 6
6 6 7
8 2
3 9
5 TYP
S
EL506 - - B SECTION
A SECTION
A- -B
S101
TRAFFIC AREASPOLE FOUNDATION
1. SEE NOTE
6-#5 MIN.
LAP SPLICE @ TOP SPIRAL.#3 SPIRAL MIN. SEE NOTE 1.
3"CLR
POLE BASE
CONC PIER
POLE
4"
MIN LBOLT ANCHOR C
CONDUIT
GRADE
ELEVATION
COMPACTED SOIL
CONCRETECLASS "A" SEE
LAP SPLICE
FINISHED
CONDUIT(S)
ELECTRICAL ENCASED
SEENOTE1.
5'-0"MIN
PITCH
3@3"
2"CLR
PITCHOF
SPIRAL
MIN
8"
3"CLR
GROUT
MIN 1" NON-SHRINK
POLE
COVER
POLE BASE
TYP
PER POLE MFR REQUIREMENTSWASHERS, AND LEVELING NUTS SST ANCHOR BOLTS, NUTS, LOCK 6"PITCH2
'-0"MIN
3'-0"
SEENOTE1
2'-0"DIAMIN
SEENOTE1
2'-0"DIAMIN
INCREASE DIMENSIONS AND INCREASE DIMENSIONS AS REQUIRED.OTHERWISE NOTED. PROVIDE WIND LOAD CALCULATIONS AND
1. USE MINIMUM DIMENSIONS AND REINFORCEMENT SHOWN UNLESS GENERAL NOTES: GENERAL NOTES:
TYP
S
EL507
POLE
CONDUIT
GRADE
SST ANCHOR BOLTS,NUTS, LOCK WASHERS,AND LEVELING NUTS PER
ELEVATION
COMPACTED SOIL
CONCRETECLASS "A"
SEE
LAP SPLICE
POLE BASE
CONC PIER
L
POLE
FINISHED
COVER
POLE BASE
CONDUIT(S)
ELECTRICAL ENCASED
GROUT
MIN 1" NON-SHRINK
1. SEE NOTE
6-#5 MIN.
LAP SPLICE @ TOP SPIRAL.#3 SPIRAL MIN. SEE NOTE 1.
TYP
S101
SEENOTE1.
5'-0"MIN
6"PITCH
PITCH
3@3"
2"CLR
A- -B -B -A SECTION SECTION PITCH OF SPIRAL 4" MIN 2'-0"MIN 3"CL B R OLT ANCHOR C MIN8" 3"CLR
NON-TRAFFIC AREASPOLE FOUNDATION
2'-0"DIAMIN
SEENOTE1
SEENOTE1
2'-0"DIAMIN
INCREASE DIMENSIONS AS REQUIRED.OTHERWISE NOTED. PROVIDE WIND LOAD CALCULATIONS AND
1. USE MINIMUM DIMENSIONS AND REINFORCEMENT SHOWN UNLESS
POLE MFR REQUIREMENTS
PlotDate:12-JUL-202312:22:20PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CE
TYPICALS
TYPICAL DETAILS
8660F10
CE
JGB
00TE03
177
8660F1000TE03.dgn
ELECTRICAL
eparker