Geotechnical Exploration, 110 S. 6th Street Warehouse, City of Industry 13877.001 Tokimatsu, K., Seed, H. B., 1987, "Evaluation of Settlements in Sands Due to Earthquake Shaking," Journal of the Geotechnical Engineering, American Society of Civil Engineers, Vol. 113, No. 8, pp. 861-878.
United States Geological Survey (USGS), 2011 , Ground Motion Parameter Calculator, Seismic Hazard Curves and Uniform Hazard Response Spectrum, Java Application , Version 5.1.0, February 10, 2011 , downloaded from http://earthquake.usgs.gov/hazards/designmaps/ javacalc.php United States Geological Survey (USGS), 2023, Areas of Land Subsidence in California, website https://ca.water.usgs.gov/land subsidence/california-subsidence-areas.html, accessed September 1, 2022.
Yerkes, R.F., McCulloh, T.H ., Schoellhamer, J.E., and Vedder, J.G., 1965, Geology of the Los Angeles Basin California - an Introduction: U.S. Geological Survey Profession Paper 420-A, 57 p.
Youd, T. L., Hanson C. M., and Bartlett, S. F., 1999, Revised MLR Equations for Predicting Lateral Spread Displacement, Proceedings of the 7th U.S.-Japan Workshop on Earthquake Resistant Design of Lifeline Facilities and Countermeasures Against Soil Liquefaction, November 19, 1999, pp. 99-114.
Youd, T.L., Idriss, I.M., Andrus, R.D., Arango, I., Castro, G., Christian, J.T., Dobry, R. , Finn, L., Harder, L.F., Hynes, M.E., Ishihara, K., Koester, J.P., Liao, S.C., Marcuson, W.F. Ill, Martin, G.R., Mitchell, J.K. , Moriwaki, Y., Power, M.S., Robertson, P.K. , Seed, R.B., Stakoe, K.H. II , 2001 , "Liquefaction Resistance of Soils: Summary Report from the 1996 NCEER and 1998 NCEER/NSF Workshops on Evaluation of Liquefaction Resistance of Soils", Journal of Geotechnical and Geoenvironmental Engineering, Vol. 127, No. 10, October 2001 . ~ Leighton A-2
a verdantas company
~ Leighton
a verdantas company
APPENDIX B
GEOTECHNICAL LOGS
Geotechnical Exploration, 110 S. 6th Street Warehouse, City of Industry 13877.001
APPENDIX B
FIELD EXPLORATION
Our field investigation consisted of a surface reconnaissance and a subsurface exploration. Approximate exploration locations are shown on Figure 2, Geotechnical Map .
Borings: On September 15 and 16, 2022, 12 hollow-stem-auger borings (LB-1 through LB-10, Ll-1 and Ll-2) were drilled, logged and sampled to depths ranging from 20 feet to 30 feet below the ground surface. Encountered soils were logged in the field by our representative and described in accordance with the Unified Soil Classification System (ASTM D 2488). Relatively undisturbed soil samples were obtained at selected intervals within these borings using both a Modified California ring-lined and Standard Penetration Test (SPT) split-spoon sampler. Standard Penetration Test (SPT) resistance blow counts were obtained by dropping a 140-pound hammer through a 30-inch free fall. The 2-inch outside diameter split-spoon sampler was driven 18 inches and the number of blows was recorded for each 6 inches of penetration (ASTM D 1586). In addition, 2.4-inch inside diameter brass ring samples were obtained using a Modified California sampler driven into the soil with the 140-pound hammer. Near surface bulk soil samples were also collected from the borings. Representative earth-material samples obtained from these subsurface explorations were transported to our geotechnical laboratory for evaluation and appropriate testing.
~ Leighton B-1
a verdantas company
Project No.
Project
Drilling Co.
Drilling Method
Location
C:
0 ·--
-Q)
IV Q)
~LL
iii
280 10
C)
:C: Cl
c..o
~...J
(!)
~i'liPLiOTYPES:
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
GEOTECHNICAL BORING LOG LB-1
13877.001 Date Drilled 4-13-23
CapRock 6th Ave Industry Warehouse Logged By _B_T_M ___ _ Martini Drilling, Inc. Hole Diameter 8" --------
Hollow Stem Auger - 140Ib - Autohammer - 30" Drop Ground Elevation 290' -------- See Figure 2 - Exploration Location Map Sampled By BTM
ti)
Q)
't,
:::::s
:;:::;
-
<
0 z
Q)
c..
E
IV
UJ
B-1
R-1
R-2
R-3
R-4
S-5
R-6
S-7
ti)
Q)
t/)..c:
3: C)
o.E
ajc.o ...
Q)
a.
9 16
19 5
8 10
4 4
8 7
9 13
2 4
5 5
9 13
2 3
4 TYPE OF TESTS:
~ ti)
c: .... Q) C)
cc.
~
C
113
106
102
111
97 -200 % FINES PASSING
AL ATTERBERG LIMITS
CN CONSOLIDATION
CO COLLAPSE
Q)~
... - :::::s-
-c:
ti) Q) ·-- oc:
:i:0
(.)
15 14
16 3
11 ui---:--
t/lU,
IV •
-u (.) . _u,
·cb
en-SC
SM
SM
SP
SC
SM
SC
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
@0.83': Clayey SAND, gray and brown, moist, low plasticity @2.5': Clayey SAND, medium dense, dark gray, moist, fine sand, low plasticity, brick and asphalt bits
@5': Silty SAND, medium dense, olive brown, moist, fine sand, trace gravel and construction debris
Young Alluvial Fan Deposits {Qyf..l
@7.5': Silty SAND, loose, olive brown, moist, fine sand, low plasticity
@11': Poorly-graded SAND, medium dense, tan, moist, fine sand, trace medium to coarse sand, trace silt, slightly oxidized, friable, 36% fines.
@15': Clayey SAND, loose, olive brown, moist, fine to medium sand, 30% fines, low plasticity, trace coarse sand
@20': Silty SAND, medium dense, olive brown, moist, fine sand, nonplastic, slightly oxidized, micaceous
@25': Sandy CLAY, medium stiff, olive brown and gray, moist to very moist, low plasticity, laminated, pockets of higher sand content, 78% fines
DS DIRECT SHEAR
ti)
-ti)
Q)
I-
-0
Q)
C.
>.
I-co
-200
-200
-200, AL
El EXPANSION INDEX
H HYDROMETER
MD MAXIMUM DENSITY
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY ~ Leighton
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
CR CORROSION
CU UNDRAINED TRIAXIAL
PP POCKET PENETROMETER
RV RVALUE
UC UNCONFINED COMPRESSIVE
STRENGTH
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 1 of 2
Project No.
Project
Drilling Co.
Drilling Method
Location
C:
0 ·--
-Q)
IV Q)
~LL
iii
C)
:C: Cl
c..o
~...J
(!)
GEOTECHNICAL BORING LOG LB-1
13877.001 Date Drilled 4-13-23
CapRock 6th Ave Industry Warehouse Logged By _B_T_M ___ _ Martini Drilling, Inc. Hole Diameter 8" --------
Hollow Stem Auger - 140Ib - Autohammer - 30" Drop Ground Elevation 290' -------- See Fii:iure 2 - Exp/oration Location Map
ti)
Q)
't,
:::::s
:;:::;
-
<
0 z
Q)
c..
E
IV
UJ
ti)
Q)
t/)..c:
3: C)
o.E
ajc.o ...
Q)
a.
~ ti)
c: .... Q) C)
cc.
~
C
Q)~
... - :::::s-
-c:
ti) Q) ·-- oc:
:i:0
(.)
ui---:--
t/lU,
IV •
-u (.) . _u,
·cb
en-Sampled By BTM
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
ti)
-ti)
Q)
I-
-0
Q)
C.
>.
I-260 30-+----+---->-----..-+---+----t---+----t------------------------+-------O R-8 15 111 2 SP @30': Poorly-graded SAND, dense, tan, slightly moist, fine to .... - 255 35-
- ....
- ....
250 40-,._._.__,__--"
- .
-
245 45-,_,_,_.,..,.,.,_,,,,__,__,
-
-
240 50-.......+-"-+-'-~
235 55-
-
H'liPLi
0 TYPEs:
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
• 30 coarse sand, some very fine granitic gravel, friable 39 S-9 8
R-10
1 14
f-f-18
6 8
13 S-11 3
R-12
'/,, 4
f-f-5
9 17
24 TYPE OF TESTS:
91 98
31 SM-ML
SC
12 SM
@35': Poorly-graded SAND, dense, tan, slightly moist, fine to coarse sand, some fine granitic gravel, friable
@40': Silty SAND to Sandy SILT, medium dense to stiff, brown and orange, moist, fine sand, 45% fines, heavily oxidized, heavily micaceous, slightly laminated
@45': Sandy Lean CLAY, stiff, dark brown, fine sand, 57% fines, low plasticity, oxidation veins, slightly micaceous
@50': Silty SAND, medium dense, medium brown, moist, fine sand, 18% fines, some oxidation staining, slightly micaceous, friable
Total Depth: 51.5' bgs
No groundwater encountered during drilling
Boring backfilled with soil cuttings and patched at surface with black-dyed concrete.
DS DIRECT SHEAR
-200, AL
-200, AL
-200
-200 % FINES PASSING
AL ATTERBERG LIMITS
CN CONSOLIDATION
CO COLLAPSE
El EXPANSION INDEX
H HYDROMETER
MD MAXIMUM DENSITY
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY
UC UNCONFINED COMPRESSIVE
STRENGTH
~ Leighton
CR CORROSION
CU UNDRAINED TRIAXIAL
PP POCKET PENETROMETER
RV RVALUE
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 2 of 2
Project No.
Project
Drilling Co.
Drilling Method
Location
C:
0 ·--
-Q)
IV Q)
~LL
iii
290
285 5-.
-.
C)
:C: Cl
c..o
~...J
(!)
280 10-,___._~_,_____,
- .
-
275 15-t-r-,.-,..,...,-,-,--,-i
-
-
270 20-.-+-"-+-'-~
265 25-
-
~i'liPLiOTYPES:
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
GEOTECHNICAL BORING LOG LB-2
13877.001 Date Drilled 4-13-23
CapRock 6th Ave Industry Warehouse Logged By _B_T_M ___ _ Martini Drilling, Inc. Hole Diameter 8" --------
Hollow Stem Auger - 140Ib - Autohammer - 30" Drop Ground Elevation 290' -------- See Fii:iure 2 - Exp/oration Location Map Sampled By BTM ti)
Q)
't,
:::::s
:;:::;
-
<
0 z
Q)
c..
E
IV
UJ
B-1
R-1
R-2
---- R-3
R-4
f-f-ti)
Q)
t/)..c:
3: C)
o.E
ajc.o ...
Q)
a.
5 5
5 1
4 3
5 11
17 5
12 19
R-5 5
• 7
13 f-S-6 4
R-7
] 6
f-8
4 12
19 TYPE OF TESTS:
~ ti)
c: .... Q) C)
cc.
~
C
105
90 112
106
112
112
-200 % FINES PASSING
AL ATTERBERG LIMITS
CN CONSOLIDATION
CO COLLAPSE
Q)~
... - :::::s-
-c:
ti) Q) ·-- oc:
:i:0
(.)
10 13
13 15
16 16
ui---:--
t/lU,
IV •
-u (.) . _u,
·cb
en-SC
SM
SM
SP
SC
SM
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
Artificial Fill, undocumented {Aful
@Surface: Grass over Clayey SAND, dark brown, moist, fine to medium sand, low plasticity
@2.5': Silty SAND, loose, brown, moist, fine sand, few medium to coarse sand, low plasticity, rootlets
@5': Silty SAND, loose, brown, very moist, fine sand, few medium to coarse sand, low plasticity, rootlets
------------------------------ Young Alluvial Fan Deposits {Qyf..l @7.5': Silty SAND, medium dense, brown, moist, mostly fine sand, few medium to coarse sand, low plasticity, trace fine gravel @10': Poorly-graded SAND, medium dense, light brown, moist, fine sand, trace medium sand, trace silt, friable
@15': Clayey SAND, medium dense, olive brown, moist to very moist, fine sand, trace medium to coarse sand, low plasticity, slightly micaceous
@20': Silty SAND, medium dense, olive brown, moist, fine sand, low to no plasticity, trace medium to coarse sand
@25': Silty SAND, medium dense, olive brown, moist, fine sand, low plasticity, oxidation staining, slightly micaceous, friable Total Depth: 26.5' bgs
No groundwater encountered during drilling
Boring backfilled with soil cuttings to surfce.
DS DIRECT SHEAR
ti)
-ti)
Q)
I-
-0
Q)
C.
>.
I-El EXPANSION INDEX
H HYDROMETER
MD MAXIMUM DENSITY
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY ~ Leighton
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
CR CORROSION
CU UNDRAINED TRIAXIAL
PP POCKET PENETROMETER
RV RVALUE
UC UNCONFINED COMPRESSIVE
STRENGTH
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 1 of 1
Project No.
Project
Drilling Co.
Drilling Method
Location
C:
0 ·--
-Q)
IV Q)
~LL
iii
C)
:C: Cl
c..o
~...J
(!)
GEOTECHNICAL BORING LOG LB-3
13877.001 Date Drilled 4-13-23
CapRock 6th Ave Industry Warehouse Logged By _B_T_M ___ _ Martini Drilling, Inc. Hole Diameter 8" --------
Hollow Stem Auger - 140Ib - Autohammer - 30" Drop Ground Elevation 290' -------- See Figure 2 - Exploration Location Map
ti)
Q)
't,
:::::s
:;:::;
-
<
0 z
Q)
c..
E
IV
UJ
ti)
Q)
t/)..c:
3: C)
o.E
ajc.o ...
Q)
a.
~ ti)
c: .... Q) C)
cc.
~
C
Q)~
... - :::::s-
-c:
ti) Q) ·-- oc:
:i:0
(.)
ui---:--
t/lU,
IV •
-u (.) . _u,
·cb
en-Sampled By BTM
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
ti)
-ti)
Q)
I-
-0
Q)
C.
>.
I-290 Q-t-r,-~~+----f-----rn----+----t---+----t------------------------i--------0 B-1 SC Artificial Fill, undocumented {Afu) -200, AL, 265 25
~i'liPLiOTYPES:
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
R-1
R-2
R-3
R-4
S-5
R-6
3 6
9 4
11 14
5 11
19 5
10 15
3 4
6 9
10 9
TYPE OF TESTS:
104
111
112
118
90 -200 % FINES PASSING
AL ATTERBERG LIMITS
CN CONSOLIDATION
CO COLLAPSE
CR CORROSION
CU UNDRAINED TRIAXIAL
@Surface: Grass over Clayey SAND, dark brown, moist, fine sand, MD ML
19 CL
45% fines (field estimate), low plasticity, rootlets
@2':Silty SAND, tan to olive brown, moist, fine sand, rootlets, trace construction debris
, moist, fine sand, low
p asltcIty, trace root els, pin o e pores, massive
16 SC-SM @7.5': Clayey Silty SAND, medium dense, olive brown, moist, fine sand, low plasticity, slightly micaceous, friable
17 SM
15 SC
SM
5 @10': Silty SAND, medium dense, olive brown, moist, fine sand, low plasticity, slightly micaceous, friable
@15': Clayey SAND, medium dense, brown to dark brown, moist, fine to medium sand, low plasticity, slightly micaceous @20': Silty SAND, loose, tan to olive brown, moist, fine sand, low plasticity, slightly micaceous
@25': Silty SAND, medium dense, tan to olive brown, moist, fine sand, nonplastic, slightly micaceous, some oxidation staining Total Depth: 26.5' bgs
No groundwater encountered during drilling
Boring backfilled with soil cuttings to surface.
DS DIRECT SHEAR
CR, El
El EXPANSION INDEX
H HYDROMETER
MD MAXIMUM DENSITY
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY
UC UNCONFINED COMPRESSIVE
STRENGTH
~ Leighton
PP POCKET PENETROMETER
RV RVALUE
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 1 of 1
GEOTECHNICAL BORING LOG LB-4
Project No. 13877.001 Date Drilled 4-13-23
Project
Drilling Co.
Drilling Method
Location
C:
0 C)
·-- ..c:_ :C: Cl -Cl) -Cl)
ra Cl) Q.CI) a.o
~LL ~LL ~...J
(!) iii
0 285
5 280
10 275
15 270
20 265
25 260
SAMPLiOTYPES:
CaQRock 6th Ave Industry Warehouse Logged By BTM
Martini Drilling, Inc. Hole Diameter 8"
Hollow Stem Auger - 140Ib -Autohammer - 30" DroQ Ground Elevation 289' See Figure 2 - Exploration Location Map
rJI >. rJI 0 Cl) ~ Cl)~ ui---:--
Cl) z r11..C: rJI ... - r11en
't, Cl) 3: C) c: .... ::::s- ra . ::::s -c: -u c.. o.E Cl) C) rJICI) (.) . - ca. ·-- _en :;:::; E ajc.o oc: - ~ ·cb <( ra ... :i:0 en Cl) C (.) en-a.
B-1 SC
R-1 5 106 10
6 7
R-2 5 103 13 SM
10 11
R-3 6 113 9
11 19
R-4 9 106 17 SP
10 17
S-5 1 CL
2 3 SC
R-6 4 96 19 SM
8 14
SP-SM
S-7 5
6 11
TYPE OF TESTS:
Sampled By BTM
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
Artificial Fill, undocumented (Afu}
@Surface: Grass over Clayey SAND, dark brown, moist, fine sand, low plasticity, rootlets, trace fine gravel
@2.5': Clayey SAND, loose, very dark brown, moist, fine sand, few medium sand, low plasticity, trace rootlets
---------------------------- ive brown, moist, mostly fine san , ew me Ium to coarse sand, low plasticity, trace rootlets, trace fine gravel
@7.5': Silty SAND, medium dense, olive brown, moist, mostly fine sand, few medium to coarse sand, low plasticity, slight oxidation staining
@10': Poorly-graded SAND, medium dense, tan, moist, mostly fine sand, few medium to coarse sand, trace fine gravel, friable, 49% fines
@15': Sandy Silty CLAY, medium stiff, olive brown, moist, fine sand, 54% fines, low plasticity, massive, slightly oxidized @16': Clayey SAND, loose, olive brown, moist, fine sand,, slightly laminated, slightly micaceous, friable
@20': Silty SAND, medium dense, olive brown, moist, fine sand, low plasticity; grading coarser toward bottom of sample, oxidation staining
@25': Poorly-graded SAND with silt to Silty SAND, medium dense, tan, moist, fine sand, slightly micaceous, friable
Total Depth: 26.5' bgs
No groundwater encountered during drilling
Boring backfilled with soil cuttings to surface
DS DIRECT SHEAR
rJI
-rJI
Cl)
I-
....
0 Cl)
Q.
>.
I-
-200
-200
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
-200 % FINES PASSING
AL ATTERBERG LIMITS
CN CONSOLIDATION
CO COLLAPSE
El EXPANSION INDEX
H HYDROMETER
MD MAXIMUM DENSITY
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY
UC UNCONFINED COMPRESSIVE
STRENGTH
~ Leighton
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
CR CORROSION
CU UNDRAINED TRIAXIAL
PP POCKET PENETROMETER
RV RVALUE
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 1 of 1
Project No.
Project
Drilling Co.
Drilling Method
Location
C:
0 ·--
-Q)
IV Q)
~LL
iii
C)
:C: Cl
c..o
~...J
(!)
GEOTECHNICAL BORING LOG IT-1
13877.001 Date Drilled 4-13-23
CaQRock 6th Ave Industry Warehouse Logged By BTM
Martini Drilling, Inc. Hole Diameter 8"
Hollow Stem Auger - 140Ib -Autohammer - 30" DroQ Ground Elevation 289' See Figure 2 - Exploration Location Map
ti)
Q)
't,
:::::s
:;:::;
-
<
0 z
Q)
c..
E
IV
UJ
ti)
Q)
t/)..c:
3: C)
o.E
ajc.o ...
Q)
a.
~ ti)
c: .... Q) C)
cc.
~
C
Q)~
... - :::::s-
-c:
ti) Q) ·-- oc:
:i:0
(.)
ui---:--
t/lU,
IV •
-u (.) . _u,
·cb
en-Sampled By BTM
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
ti)
-ti)
Q)
I-
-0
Q)
C.
>.
I-o-+--r,-~~-+----+---~-+---t-----+----+----t-------------------------+-------- sc Artificial Fill, undocumented {Aful 285
S-1
280 S-2
4 4
6 SC
@Surface: Grass over Clayey SAND, dark brown, moist, fine sand, 25-35% fines (field estimate), low plasticity, trace fine gravel , rootlets
n, moist, fine sand, low
p asltc1ty, trace root els, ew me ium to coarse sand
5 SM @8.5: Silty SAND, medium dense, olive brown, moist, fine sand, 6 trace medium to coarse sand, 25% fines, slight oxidation -200
10-,--+-~,--,--11--+-7_1 _ 1 __ 1 _ 7 ----.____::s~ta~i~ni~n~, s~l~i~h~tl~m~i~ca~c~e~o~u~s _____________ --7 275
15 270
20 265
25 260
SAMPLiOTYPES:
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
TYPE OF TESTS:
-200 % FINES PASSING
AL ATTERBERG LIMITS
CN CONSOLIDATION
CO COLLAPSE
CR CORROSION
CU UNDRAINED TRIAXIAL
Total Depth: 10' bgs
No groundwater encountered during drilling
Temporary percolation well installed; screened 5-10' bgs Upon completion of infiltration testing, boring backfilled with soil cuttings to surface
DS DIRECT SHEAR
El EXPANSION INDEX
H HYDROMETER
MD MAXIMUM DENSITY
PP POCKET PENETROMETER
RV RVALUE
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY
UC UNCONFINED COMPRESSIVE
STRENGTH
~ Leighton
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 1 of 1
GEOTECHNICAL BORING LOG IT-2
Project No. 13877.001 Date Drilled 4-13-23
Project
Drilling Co.
CapRock 6th Ave Industry Warehouse Logged By _B_T_M ___ _ Martini Drilling, Inc. Hole Diameter -------8"
Dri Iii ng Method Hollow Stem Auger - 140Ib - Autohammer - 30" Drop Ground Elevation ------- 290'
Location
C:
0 ·--
-Q)
IV Q)
~LL
iii
290 0
285 5-
280 10-
-
-
275 15-
C)
:C: Cl
c..o
~...J
(!)
See Fii:iure 2 - Exp/oration Location Map
ti)
Q)
't,
:::::s
:;:::;
-
<
0 z
Q)
c..
E
IV
UJ
f-f-ti)
Q)
t/)..c:
3: C)
o.E
ajc.o ...
Q)
a.
~ ti)
c: .... Q) C)
cc.
~
C
Q)~
... - :::::s-
-c:
ti) Q) ·-- oc:
:i:0
(.)
ui---:--
t/lU,
IV •
-u (.) . _u,
·cb
en-Sampled By BTM
SOIL DESCRIPTION
This Soil Description applies only to a location of the exploration at the time of sampling. Subsurface conditions may differ at other locations and may change with time. The description is a simplification of the actual conditions encountered. Transitions between soil types may be gradual.
270 2o-t---c~~+----t-----+-+--2--t---+----t-S-M--,-Y-o-u-na_Al_l_u_vi_a_l F_a_n_D_e-,nn-s,-it_s_/Ovf--__ \------------< ] 4 @LU': ::;11ty ::iANU, loose, olive brown, moist, fine sand, low 5 plasticity, slightly micaceous
4 SP-SM @23.5': Silty SAND to Poorly-graded SAND with silt, medium 6 dense, tan to olive brown, moist, fine sand, few medium sand, 265 25-t=Q'.Z~"----1----1'-1--~5_j __ _j__-1~.,~L--i.... 6% fines ! @25': Lean CLAY, olive brown, moist, low plasticity, laminated, - ~ oxidation staininq - f-
~i'liPLiOTYPES: TYPE OF TESTS:
-200 % FINES PASSING OS
Total Depth: 26.5' bgs
No groundwater encountered during drilling
Temporary percolation well installed; screened 15-25' bgs Upon completion of infiltration testing, boring backfilled with soil cuttings to surface.
ti)
-ti)
Q)
I-
-0
Q)
C.
>.
I-
-200
B BULK SAMPLE
C CORE SAMPLE
G GRAB SAMPLE
R RING SAMPLE
AL ATTERBERG LIMITS El
CN CONSOLIDATION H
CO COLLAPSE MD
DIRECT SHEAR
EXPANSION INDEX
HYDROMETER
MAXIMUM DENSITY
POCKET PENETROMETER
RVALUE
SA SIEVE ANALYSIS
SE SAND EQUIVALENT
SG SPECIFIC GRAVITY
UC UNCONFINED COMPRESSIVE
STRENGTH
~ Leighton
S SPLIT SPOON SAMPLE
T TUBE SAMPLE
CR CORROSION PP
CU UNDRAINED TRIAXIAL RV
* * * This log is a part of a report by Leighton and should not be used as a stand-alone document. * * * Page 1 of 1
Results of Falling Head Infiltration Test
Project: 13877.001
Exploration #/Location: IT-1
Depth Boring drilled, bgs (fl): 10
Tested by: BTM
uses Soil Type in test zone: SM
Weather (start to finish): Overcast
Water Source/pH: H2O
Measured boring diameter: in. 4 in. W ell Radius
Depth to GW or aquitard, bgs: 100 ft
Initial estimated Depth to Water Surface (in.):
Average depth of water in v.-elt, "h" (in.):
85 35
approx. h/r: 8.7
Tu (Fig. 8) (ft): 92.9
Tu>3h?: yes, OK
Well Prep: Drilled to 10', place sand at bottom, slotted 2" pipe for bottom 5 feet, sand around slotted section ,...~ft~~-~i!l.. =•--, Total (in.)
Depth to bottom of well measured from top of auger (or ground su 10.2 ft 0. in. 122 Depth of well bottom below top of cas ing (in): 125 Casing stickup measured above top of auger (or ground surface) ( O. ft 3. in. 3 Depth to top of sand from top of casing 4. ft 2. in.
Field Data Calc ulations
Data from Flow Refilled? Date Time Depth to WL in Meter Total h, Boring Water Lit Elapsed Depth to Height of Vol Change (in."3) (measured Temp (min) Time Wlin Water in l>h (in.) Avg. h Reading Interval from top of (deg F) (o, (min) v.ell (in.) Well (in.) (gallons) Pulse casing) Comments) Start Date Start time: Count from from Total
4/13/2023 8:10 Gallons ft n. supply l>h
/13/23 8:16 6.81 6 78.7 43.7
/13/23 8:19 7.12 3 9 82.4 40.0 -3.72 42 0 64 64
/13/23 8:22 7.49 3 12 86.9 35.5 -4.44 38 0 77 77
/13/23 8:25 7.75 3 15 90.0 32.4 -3.12 34 0 54 54
/13/23 8:28 7.99 3 18 92.9 29.5 -2.88 31 0 50 50
/13/23 8:31 8.22 3 21 95.6 26.8 -2.76 28 0 48 48
/13/23 8:34 8.43 3 24 98.2 24.2 -2.52 26 0 44 44
/13/23 8:37 8.58 3 27 100.0 22.4 -1.8 23 0 31 31
/13/23 8:40 8.72 3 30 101 .6 20.8 -1 .68 22 0 29 29
/13/23 8:58 5.5 48 63.0 59.4
/13/23 9:00 5.89 2 50 67.7 54.7 -4.68 57 0 81 81
/13/23 9:02 6.14 2 52 70.7 51 .7 -3 53 0 52 52
/13/23 9:04 6.31 2 54 72.7 49.7 -2.04 51 0 35 35
/13/23 9:06 6.59 2 56 76.1 46.3 -3.36 48 0 58 58
/13/23 9:08 6.78 2 58 78.4 44.0 -2.28 45 0 39 39
/13/23 9:10 6.95 2 60 80.4 42.0 -2.04 43 0 35 35
/13/23 9:15 7.41 5 65 85.9 36.5 -5.52 39 0 95 95
/13/23 9:20 7.77 5 70 90.2 32.2 -4.32 34 0 75 75
/13/23 9:25 8.12 5 75 94.4 28.0 -4.2 30 0 73 73
/13/23 9:30 8.45 5 80 98.4 24.0 -3.96 26 0 68 68
/13/23 9:35 8.69 5 85 101 .3 21 .1 -2.88 23 0 50 50
/13/23 9:40 8.9 5 90 103.8 18.6 -2.52 20 0 44 44
/13/23 9:45 9.1 5 95 106.2 16.2 -2.4 17 0 42 42
/13/23 9:54 5.5 104 63.0 59.4
/13/23 9:59 6.13 5 109 70.6 51 .8 -7.56 56 0 131 131
/13/23 10:04 6.66 5 11 4 76.9 45.5 -6.36 49 0 110 110
/13/23 10:09 7.09 5 119 82.1 40.3 -5.16 43 0 89 89
/13/23 10:14 7.5 5 124 87.0 35.4 -4.92 38 0 85 85
/13/23 10:19 7.85 5 129 91.2 31 .2 -4.2 33 0 73 73
/13/23 10:24 8.19 5 134 95.3 27. 1 -4.08 29 0 71 71
/13/23 10:29 8.5 5 139 99.0 23.4 -3.72 25 0 64 64
/13/23 10:34 8.71 5 144 101 .5 20.9 -2.52 22 0 44 44
/13/23 10:39 8.92 5 149 104.0 18.4 -2.52 20 0 44 44
/13/23 10:40 5.5 150 63.0 59.4
/13/23 10:45 6.16 5 155 70.9 51 .5 -7.92 55 0 137 137
/13/23 10:50 6.67 5 160 77.0 45.4 -6.12 48 0 106 106
/13/23 10:55 7.11 5 165 82.3 40.1 -5.28 43 0 91 91
/13/23 11:00 7.52 5 170 87.2 35.2 -4.92 38 0 85 85
/13/23 11:05 7.89 5 175 91.7 30.7 -4.44 33 0 77 77
/13/23 11:10 8.23 5 180 95.8 26.6 -4.08 29 0 71 71
/13/23 11:15 8.52 5 185 99.2 23.2 -3.48 25 0 60 60
/13/23 11:20 8.73 5 190 101 .8 20.6 -2.52 22 0 44 44
/13/23 11:25 8.95 5 195 104.4 18.0 -2.64 19 0 46 46
Flow
(in"3/
min)
21 26
18 17
16 15
10 10
40 26
18 29
20 18
19 15
15 14
10 9
8 26
22 18
17 15
14 13
9 9
27 21
18 17
15 14
12 9
9 Cross-sectional area for flow calcs based on 6-h
Well pack sa nd porosity §§.3 Casing outer diameter, in . 2.3 Casing inner diameter, in. 2.1
Cross-sectional area, in .... 2 17.3
Use of Barrels: No f-----1
Use of Flow Meter: No f-----1
Test Type: Falling Head
K20, Average Infiltration Coef. Of q, Infiltration V Perme- Rate Flow Surface (Fig 9) ability at [fl ow/surf
(in"3/ hr) Area, 20 deg C area] {in./hr)
(in"2) (FS=1 ) (in./hr)
1287 0.9 0.25 1.08
1536 0.9 0.36 1.42
1079 0.9 0.29 1.10
996 0.9 0.31 1.11
955 0.9 0.35 1.16
872 0.9 0.37 1.16
623 0.9 0.29 0.90
581 0.9 0.31 0.90
2428 0.9 0.29 1.51
1557 0.9 0.20 1.03
1059 0.9 0.15 0.74
1744 0.9 0.27 1.28
1183 0.9 0.20 0.92
1059 0.9 0.19 0.86
1146 0.9 0.26 1.02
897 0.9 0.25 0.91
872 0.9 0.30 1.00
822 0.9 0.36 1.08
598 0.9 0.31 0.89
523 0.9 0.33 0.88
498 0.9 0.38 0.94
1569 0.9 0.21 1.00
1320 0.9 0.21 0.96
1071 0.9 0.21 0.87
1021 0.9 0.24 0.94
872 0.9 0.25 0.91
847 0.9 0.31 1.00
772 0.9 0.35 1.04
523 0.9 0.28 0.79
523 0.9 0.34 0.89
1644 0.9 0.22 1.05
1270 0.9 0.21 0.92
1096 0.9 0.22 0.90
1021 0.9 0.25 0.95
922 0.9 0.27 0.97
847 0.9 0.31 1.01
722 0.9 0.33 0.98
523 0.9 0.28 0.80
548 0.9 0.36 0.94
Minimum Rate: 0.74
Raw Rate for design, prior to appl ication of adjustment factors: 1.00
Results of Falling Head Infiltration Test
Project: 13877.001
Exploration #/Location: IT-2
Depth Boring drilled, bgs (fl): 25
Tested by: BTM
uses Soil Type in test zone: SP-SM
Weather (start to finish): Overcast
Water Source/pH: H20
Measured boring diameter: in. 4 in. W ell Radius
Depth to GW or aquitard, bgs: 100 ft
Initial estimated Depth to Water Surface (in.):
Average depth of water in v.-elt, "h" (in.):
251
52 approx. h/r: 13.1
Tu (Fig. 8) (ft): 79.1
Tu>3h?: yes, OK
Well Prep: Drilled to 25', place sand at bottom, slotted 2" pipe for bottom 10 feet, sand around slotted section ,...~ft~~-~i!l.. =•--, Total (in.)
Depth to bottom of well measured from top of auger (or ground su 25.4 ft O. in. 305 Depth of well bottom below top of casing (in): 306 Casing stickup measured above top of auger (or ground surface) ( O. ft 1. in. t---;.-----i Depth to top of sand from top of casing .._1_2_. _fl_.__4_. _in_. _, Field Data Calculations
Data from Flow Refilled? Date Time Depth to WL in Meter Total h, Boring Water Lit Elapsed Depth to Height of Vol Change (in."3) (measured Temp (min) Time Wlin Water in l>h (in. ) Avg. h Reading Interval from top of (deg F) (o, (min) well (in.) Well (in.) (gallons) Pulse casing) Comments) Start Date Start time: Count from from Total 4/13/2023 12:35 Gallons ft n. supply l>h
/13/23 12:42 4885.78 21.27 7 254.2 50.6
/13/23 12:44 4886.17 21.26 2 9 254.1 50.7 0.12 51 90 -2 88 /13/23 12:46 4886.56 21.26 2 11 254.1 50.7 0 51 90 0 90 /13/23 12:48 4886.95 21.26 2 13 254.1 50.7 0 51 90 0 90 /13/23 12:50 4887.34 21.25 2 15 254.0 50.8 0.12 51 90 -2 88 /13/23 12:55 4888.29 21.2 5 20 253.4 51.4 0.6 51 219 -10 209 /13/23 13:00 4889.26 21.11 5 25 252.3 52.5 1.08 52 224 -19 205 /13/23 13:05 4890.25 21.08 5 30 252.0 52.8 0.36 53 229 -6 222 /13/23 13:10 4891.23 21.06 5 35 251 .7 53.1 0.24 53 226 -4 222 /13/23 13:15 4892.2 21.04 5 40 251 .5 53.3 0.24 53 224 -4 220 /13/23 13:20 4893.16 21.03 5 45 251.4 53.4 0.12 53 222 -2 220 /13/23 13:25 4894.12 21.01 5 50 251 .1 53.7 0.24 54 222 -4 218 /13/23 13:30 4895.04 21.02 5 55 251.2 53.6 -0.12 54 213 2 215 /13/23 13:40 4896.9 21.02 10 65 251.2 53.6 0 54 430 0 430 /13/23 13:50 4898.77 21.01 10 75 251 .1 53.7 0.12 54 432 -2 430 /13/23 14:00 4900.66 21.02 10 85 251.2 53.6 -0.12 54 437 2 439 /13/23 14:10 4902.56 21.06 10 95 251 .7 53.1 -0.48 53 439 8 447 /13/23 14:20 4904.48 21.08 10 105 252.0 52.8 -0.24 53 444 4 448 /13/23 14:30 4906.41 21.1 10 115 252.2 52.6 -0.24 53 446 4 450 /13/23 14:40 4908.29 21.11 10 125 252.3 52.5 -0.12 53 434 2 436 /13/23 14:50 4910.17 21.11 10 135 252.3 52.5 0 52 434 0 434 /13/23 15:00 4912.02 21.13 10 145 252.6 52.2 -0.24 52 427 4 432 /13/23 15:10 4913.88 21.13 10 155 252.6 52.2 0 52 430 0 430 /13/23 15:20 4915.67 21.12 10 165 252.4 52.4 0.12 52 413 -2 411 /13/23 15:30 4917.57 21.11 10 175 252.3 52.5 0.12 52 439 -2 437 /13/23 15:40 4919.47 21.1 10 185 252.2 52.6 0.12 53 439 -2 437 Flow
(in"3/
min)
44 45
45 44
42 41
44 44
44 44
44 43
43 43
44 45
45 45
44 43
43 43
41 44
44 Cross-sectional area for flow calcs based on 6-h
Well pack sand porosity §§.3 Casing outer diameter, in . 2.3 Ca sing inner diameter, in. 2.1
Cross-sectional area, in .... 2 17.3
Use of Barrels: No f-----1
Use of Flow Meter: No f-----1
Test Type: Falling Head
K20, Average Infiltration Coef. Of q, Infiltration V Perme- Rate Flow Surface (Fig 9) ability at [fl ow/surf
(in"3/ hr) Area, 20 deg C area] {in./hr)
(in"2) (FS=1 ) (in./hr)
2640 1322 0.9 0.35 1.84
2703 1324 0.9 0.36 1.88
2703 1324 0.9 0.36 1.88
2640 1326 0.9 0.35 1.84
2509 1335 0.9 0.32 1.73
2465 1356 0.9 0.31 1.68
2670 1374 0.9 0.33 1.79
2667 1381 0.9 0.33 1.78
2639 1387 0.9 0.32 1.75
2636 1392 0.9 0.32 1.75
2611 1396 0.9 0.31 1.72
2575 1398 0.9 0.31 1.70
2578 1396 0.9 0.31 1.70
2579 1398 0.9 0.31 1.70
2632 1398 0.9 0.32 1.74
2683 1390 0.9 0.33 1.78
2686 1381 0.9 0.33 1.79
2700 1375 0.9 0.34 1.81
2618 1371 0.9 0.33 1.76
2606 1369 0.9 0.33 1.75
2589 1366 0.9 0.33 1.75
2578 1363 0.9 0.32 1.74
2468 1365 0.9 0.31 1.67
2621 1368 0.9 0.33 1.77
2621 1371 0.9 0.33 1.76
Minimum Rate: 1.67
Raw Rate for design, prior to application of adjustment factors : 1.70
APPENDIX C
LABORATORY TEST RESULTS
~ Leighton
a verdantas company
Geotechnical Exploration, 110 S. 6th Street Warehouse, City of Industry 13877.001
APPENDIXC
GEOTECHNICAL LABORATORY TESTING
The geotechnical laboratory testing program was directed toward a quantitative and qualitative evaluation of the physical and mechanical properties of the soils underlying the site and to aid in verifying soil classification.
In-Situ Moisture and Density: The natural water content (ASTM D 2216) and in-situ dry density (ASTM D 2937) were determined for recovered relatively undisturbed ring-lined barrel drive samples, from our subsurface explorations. Results of these tests are shown on the logs at the appropriate sample depths, in Appendix B.
Sieve Analysis: Sieve analyses (ASTM D 422) were performed on selected subsurface soil samples . These tests were performed to assist in the classification of the soil.
Results of these tests are presented on the "Particle Size Analysis of Soils" figures .
Collapse Potential: Collapse potential tests were performed on selected soil samples in general accordance with ASTM Standard Test Method D 5333. Test results are presented on the "One Dimensional Swell or Settlemenf' figure.
Modified Proctor Compaction Curve: A laboratory modified Proctor compaction test (ASTM D 1557) was performed on a bulk soil sample to determine maximum laboratory dry density and optimum moisture content. Result of this test is presented on the following "Modified Proctor Compaction Tesf' plot in this appendix.
Percent Passing No. 200 Sieve: Percent fines (silt and clay) passing the No. 200 U.S.
Standard Sieve was determined for soil samples in accordance with ASTM D1140 Standard Test Method. Samples were dried and passed through a No. 4 sieve, then a No. 200 sieve. Result of grain size analyses, as percent by dry weight passing the No. 200 U.S. Standard Sieve, is tabulated in this appendix and entered on our boring logs.
R-value Test: One R-value test was performed on collected bulk soil sample to evaluate pavement support characteristics of the near-surface soils. R-value test was performed in accordance with Caltrans Standard Test Method 301 . The test result is presented in this appendix.
Corrosivity Tests: To evaluate the corrosion potential of the subsurface soils at the site, we tested representative bulk samples collected during our subsurface investigation for pH, resistivity and soluble sulfate and chloride content testing. Results of these tests are presented at the end of this appendix.
~ Leighton C-1
a verdantas company
~ Leighton MODIFIED PROCTOR COMPACTION TEST
ASTM D 1557
Project Name: CapRock/6th Avenue/GE Tested By: M. Vinet -~-~---~------ Date: 04/26/23 Project No.: 13877.001 Input By: M. Vinet Date: 04/27 /23 Boring No.: LB-3 Depth (ft.): 0 - 5.0
Sample No.: B-1
Soil Identification: Clayey Sand (SC), Dark Brown.
Preparation Method: [x] Moist
□ Dry
Mold Volume (ft3 ) 0.03340
TEST NO. 1 2
Wt. Compacted Soil + Mold (g) 5402 5513
Weight of Mold (g) 3522 3522
Net Weight of Soil (g) 1880 1991
Wet Weight of Soil + Cont. (g) 856.2 831.4
Dry Weight of Soil + Cont. (g) 815.0 783.2
Weight of Container (g) 328.2 327.7
Moisture Content (%) 8.5 10.6
Wet Density (pcf) 124.1 131.4
Dry Density (pcf) 114.4 118.8
[iJ Mechanical Ram
D Manual Ram
Ram Weight= 10 lb.; Drop= 18 in.
3 4 5
5572 5534
3522 3522
2050 2012
863.3 729.6
812.9 676.6
415.0 326.1
12.7 15.1
135.3 132.8
120.1 115.4
6 Maximum Dry Density (pcf) 120.2 Optimum Moisture Content (%)1 12.3
PROCEDURE USED
D Procedure A
Soil Passing No. 4 (4.75 mm) Sieve
Mold : 4 in. (101.6 mm) diameter
Layers : 5 (Five)
Blows per layer : 25 (twenty-five)
May be used if +#4 is 20% or less
[XI Procedure B
Soil Passing 3/8 in. (9.5 mm) Sieve
;;:-- Mold : 4 in. (101.6 mm) diameter o
Layers : 5 (Five) E:
>,
125.0
120.0
Blows per layer : 25 (twenty-five)
Use if + # 4 is >20% and +3/8 in. is
20% or less
~ 115.0
C:
D Procedure C
Soil Passing 3/4 in. (19.0 mm) Sieve
Mold : 6 in. (152.4 mm) diameter
Layers : 5 (Five)
Blows per layer : 56 (fifty-six)
Use if +3/8 in. is >20% and+¾ in.
is <30%
Particle-Size Distribution:
I I GR:SA:FI
Atterber Limits:
28:20:8
Cl)
C
~
C
110.0
105.0
5.0 .,,r
I'
j
I
' '
10.0 \ \ \
\ \ \ I I I ~ SP. GR. = 2.65
V A .....-- SP. GR.= 2.70 L-------'
\ \ ~ SP. GR.= 2.75
............-
"-- \\ \
" \ \\ ' \ \ I\ " \ \ ~\ ' \ \ \ ~ I\' ,\
\ \ I\
\' ,\
\ \\
I\\ \
\ \,
I\' 'I\ \ I\ I\
I\' \\
\\ \
\ I\\
15.0 20.0
Moisture Content (%) Compaction; LB-3, B-1 /04-03-23)
25.
Boring No. LB-1 LB-1 LB-1 LB-1 LB-1 LB-1 LB-4 LB-4
Sample No. R-4 S-5 S-7 R-10 S-11 R-12 R-4 S-5
Depth (ft.) 10.0 15.0 25.0 40.0 45.0 50.0 10.0 15.0
Sample Type RING SPT SPT RING SPT RING RING SPT
Soil Classification SM SC SM SM s(CL) SM SM s(CL)
Soak Time (min) 10 10 10 10 10 10 10 10
Moisture Correction
Wet Weight of Soil + Container (gm.) 604.5 677.3 654.2 553.5 629.5 650.8 626.4 654.6 Dry Weight of Soil+ Container (gm .) 576.7 641 .5 566.1 487.5 566.7 616.5 578.3 595.7 Weight of Container (gm) 277.8 279.6 276.0 279.0 276.5 277.8 281 .8 278.4 Moisture Content(%) 9.3 9.9 30.4 31 .7 21.6 10.1 16.2 18.6 Container No.: K2 B1 R2 BL xw MA LA WO
Sample Dry Weight Determination
Weight of Sample+ Container (gm.) 576.7 641 .5 566.1 487.5 566.7 616.5 578.3 595.7 Weight of Container (gm .) 277.8 279.6 276.0 279.0 276.5 277.8 281.8 278.4 Weight of Dry Sample (gm .) 298.9 361 .9 290.1 208.5 290.2 338.7 296.5 317.3 Container No.: K2 B1 R2 BL xw MA LA WO
After Wash
Dry Weight of Sample + Container (gm) 470.4 533.0 338.5 394.3 400.8 554.9 433.5 424.0 Weight of Container (gm) 277.8 279.6 276.0 279.0 276.5 277.8 281 .8 278.4 Drv Weiqht of Sample (qm) 192.6 253.4 62.5 115.3 124.3 277.1 151 .7 145.6 % Passing No. 200 Sieve 36 30 78 45 57 18 49 54
% Retained No. 200 Sieve 64 70 22 55 43 82 51 46
~ Leighton PERCENT PASSING Project Name: CapRock/6th Avenue/GE Project No.: 13877.001
No. 200 SIEVE Client Name: CapRock Acquisitions Ill, LLC ASTM D 1140 Tested By: M. Vinet Date: 05/01/23
200 Wash (04-03-23) - ADD/TONAL
Boring No. LB-3 IT-1 IT-2
Sample No. B-1 S-2 S-2
Depth (ft.) 0 - 5.0 8.5 23.5
Sample Type BULK SPT SPT
Soil Classification SC SM SP-SM
Soak Time (min) 10 10 10
Moisture Correction
Wet Weight of Soil + Container (gm.) 683.2 613.9 607.0
Dry Weight of Soil+ Container (gm .) 630.5 584.4 591.8
Weight of Container (gm) 276.3 277.5 280.0
Moisture Content(%) 14.9 9.6 4.9
Container No. : R2 AB PO
Sample Dry Weight Determination
Weight of Sample+ Container (gm.) 630.5 584.4 591.8
Weight of Container (gm .) 276.3 277.5 280.0
Weight of Dry Sample (gm .) 354.2 306.9 311.8
Container No.: R2 AB PO
After Wash
Dry Weight of Sample + Container (gm) 471 .7 508.9 573.4 Weight of Container (gm) 276.3 277.5 280.0
Drv Weiqht of Sample (qm) 195.4 231.4 293.4
% Passing No. 200 Sieve 45 25 6
% Retained No. 200 Sieve 55 75 94
~ Leighton PERCENT PASSING Project Name: CapRock/6th Avenue/GE Project No.: 13877.001
No. 200 SIEVE Client Name: CapRock Acquisitions Ill, LLC ASTM D 1140 Tested By: M. Vinet Date: 04/26/23
200 Wash (04-03-23)
~ Leighton ATTERBERG LIMITS
ASTM D4318
Project Name: CapRock/6th Avenue/GE Tested By: M. Vinet Date: 05/03/23 Project No. : 13877.001 Input By: M. Vinet Date: 05/03/23 Boring No.: LB-1 Checked By: M. Vinet
Sample No.: R-10 Depth (ft.) 40.0
Soil Identification: Silty Sand (SM), Dark Brown.
TEST
NO.
Number of Blows [NJ
Wet Wt. of Soil + Cont. (g)
Dry Wt. of Soil + Cont. (g)
Wt. of Container (g)
Moisture Content(%) [Wn]
Liquid Limit
Plastic Limit
Plasticity Index
Classification
PLASTIC LIMIT
Non-Plastic (NP)
60 NP
NP 50
NP 0::: 40
SM X
Q)
-0 30 -'=
~ ·c::;
LIQUID LIMIT
1 2 3 4
Non-Plastic (NP)
For classification of fine-grained soils and fine-grained fraction of coarse-grained soils CH or OH
PI at "A" - Line = 0.73(LL-20) = ----~
ti 20 Ctl
0:::
One - Point Liquid Limit Calculation 0.121 10 MH or OH LL =Wn(N/25)
PROCEDURES USED
D Wet Preparation
Multipoint - Wet
w Dry Preparation
Multipoint - Dry
w Procedure A
Multipoint Test
D Procedure B
One-point Test
0 ----....... - ....... - ....... -------------""" 0 10 20 30 40 50 60 70 80 90 100 Liquid Limit (LL)
31 -r--....--....... .,......,r--r-....,....'T"""'l'""T""....,...'T"'T'"T"T"'r-T"T"T"T"r-T"T"T"'T"T"'r-T"T'T.,..,..,.,"T'T'Ti'TT""---r--~---..-.----, >----,f----+--+-- + ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ................ , .............. , .. .. , ·1----------<f----+-- I 30 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< >----,f----+--+----< ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ................ , .............. , .. .. , ·1---------<f----+-- I ~ 29 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< ~
-
C:
$
1-----,f----+--+- +········· ........ ........ ....... ...... ...... ...... ..... ..... .... ... . ............... ... ... ...... ... ......... ... ...... ......... . . . .. ·1----------lf---+-- t C:
o 28 +--+--+--+------,1-+-+-+-+-+-1-+-+-+-+-+-f-+-+++l-++t++-f+H+++,-t+H-+t---+--+----+-t--l (.)
~ 1-----,f----+--+- +········· ........ ........ ....... ...... ...... ...... ..... ..... .... ... . ............... ... ... ...... ... ......... ... ...... ......... . . . .. ·1----------lf---+-- t ::I
-ti) ·o 27 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< :ii:: >----,f----+--+----; ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ................ , .............. , .. .. , ·1----------<f----+-- I 26 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< ·········· 1 ...... ······· 1111 ................ ............ .............. ·· 1 ....... ··· 11 11 .... 1111 ... . 25 __ _.___.__......_.'-'-_,__ .......... _._....,._......_ ................ ""-+-.................. u...+ ................. _____ -+---+-+------1 10 20 25 30
Number of Blows
40 50 60 70 80 90 100
~ Leighton ATTERBERG LIMITS
ASTM D4318
Project Name: CapRock/6th Avenue/GE Tested By: M. Vinet Date: 05/03/23 Project No. : 13877.001 Input By: M. Vinet Date: 05/03/23 Boring No.: LB-1 Checked By: M. Vinet
Sample No.: S-7 Depth (ft.) 25.0
Soil Identification: Silty Sand (SM), Dark Brown.
TEST
NO.
Number of Blows [NJ
Wet Wt. of Soil + Cont. (g)
Dry Wt. of Soil + Cont. (g)
Wt. of Container (g)
Moisture Content(%) [Wn]
Liquid Limit
Plastic Limit
Plasticity Index
Classification
PLASTIC LIMIT
Non-Plastic (NP)
60 NP
NP 50
NP 0::: 40
SM X
Q)
-0 30 -'=
~ ·c::;
LIQUID LIMIT
1 2 3 4
Non-Plastic (NP)
For classification of fine-grained soils and fine-grained fraction of coarse-grained soils CH or OH
PI at "A" - Line = 0.73(LL-20) = ----~
ti 20 Ctl
0:::
One - Point Liquid Limit Calculation 0.121 10 MH or OH LL =Wn(N/25)
PROCEDURES USED
D Wet Preparation
Multipoint - Wet
w Dry Preparation
Multipoint - Dry
w Procedure A
Multipoint Test
D Procedure B
One-point Test
0 ----....... - ....... - ....... -------------""" 0 10 20 30 40 50 60 70 80 90 100 Liquid Limit (LL)
31 -r--....--....... .,......,r--r-....,....'T"""'l'""T""....,...'T"'T'"T"T"'r-T"T"T"T"r-T"T"T"'T"T"'r-T"T'T.,..,..,.,"T'T'Ti'TT""---r--~---..-.----, >----,f----+--+-- + ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ................ , .............. , .. .. , ·1----------<f----+-- I 30 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< >----,f----+--+----< ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ................ , .............. , .. .. , ·1---------<f----+-- I ~ 29 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< ~
-
C:
$
1-----,f----+--+- +········· ........ ........ ....... ...... ...... ...... ..... ..... .... ... . ............... ... ... ...... ... ......... ... ...... ......... . . . .. ·1----------lf---+-- t C:
o 28 +--+--+--+------,1-+-+-+-+-+-1-+-+-+-+-+-f-+-+++l-++t++-f+H+++,-t+H-+t---+--+----+-t--l (.)
~ 1-----,f----+--+- +········· ........ ........ ....... ...... ...... ...... ..... ..... .... ... . ............... ... ... ...... ... ......... ... ...... ......... . . . .. ·1----------lf---+-- t ::I
-ti) ·o 27 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< :ii:: >----,f----+--+----; ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ................ , .............. , .. .. , ·1----------<f----+-- I 26 +--+--+-+------al-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+1----+--+---+-+-----< ·········· 1 ...... ······· 1111 ................ ............ .............. ·· 1 ....... ··· 11 11 .... 1111 ... . 25 __ _.___.__......_.'-'-_,__ .......... _._....,._......_ ................ ""-+-.................. u...+ ................. _____ -+---+-+------1 10 20 25 30
Number of Blows
40 50 60 70 80 90 100
~ Leighton ATTERBERG LIMITS
ASTM D4318
Project Name: CapRock/6th Avenue/GE Tested By: M. Vinet Date: 05/03/23 Project No. : 13877.001 Input By: M. Vinet Date: 05/03/23 Boring No.: LB-1 Checked By: M. Vinet
Sample No.: S-11 Depth (ft.) 45.0
Soil Identification: Sandy Lean Clay s(CL), Dark Brown.
TEST
NO.
Number of Blows [NJ
Wet Wt. of Soil + Cont. (g)
Dry Wt. of Soil + Cont. (g)
Wt. of Container (g)
Moisture Content(%) [Wn]
Liquid Limit
Plastic Limit
Plasticity Index
Classification
PLASTIC LIMIT LIQUID LIMIT
1 2 3 4
15 25 35
21.67 23.22 24.22 25.09 30.42
20.29 21.54 21.63 22.36 26.48
13.78 13.65 13.84 13.68 13.61
21.20 21.29 33.25 31.45 30.61
60 -r-------------,---------, 31
21 10
CL
50 0::: 40
X
Q)
~ 30
For classification of fine-grained soils and fine-grained fraction of coarse-grained soils CH or OH
PI at "A" - Line = 0.73(LL-20) ~I _8_._03_~
One - Point Liquid Limit Calculation
10 0.121
LL =Wn(N/25) MH or OH
0 ---....... - ....... - ....... -------------""" 0 10 20 30 40 50 60 70 80 90 100 PROCEDURES USED Liquid Limit (LL)
D Wet Preparation
35 -r-....--....... .,......,r--r-....,....-r--r""T""".-,-'T""T'"T"T""r-T"T"T"T"r-T"T"T'"T"T'"..,..,....,..,..,.,"T'T'Ti"TT"""---r--~---..-.----, 1----,f--t--+- +········· ................................... ...... ..... ..... .... ................... ... ... ...... ... ......... ... ...... ......... .. . .. ·t------if---+-- t Multipoint - Wet 34 +--+-+-+----,1-+-+-+-+-+-1-+-+-+-+-+-f-+-+++l-++l++-f+H+H,-++H-+t---+--+---+-+-------1 ....................... ········· z:: .......................................... ...... .......... .... ..................... ... ........ ......... ... ............... .. ... •t-----+- --1··············· .............. ............ . w Dry Preparation ~ Multipoint - Dry ~
-
C:
Cl)
-
C:
w 0
Procedure A (.)
Cl)
...
"--.It
33 +--+--+-+------af-+~-'"+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+t----+--+---+-+-----< l'--1'-- ········· ................ ·······"-c::::: ...... .............. ........... ................. ...... ............................. ... ·1----------<f----+-- I 32 +--+-+-+----,1-+-+-+-+-+-t---P--i,-+- " +-+-f-+-+++l-++l++-f+H+H,-++H-+t---+--+---+-+-------1 ['--._'-,.._
·, ~ ............. ...... .............................. ... ·t-----+- --1··············· ........................... . 31 +--+--+-+------af-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+t----+--+---+-+-----< Multipoint Test ::I
-ti) t----,,----+--+----<········· ........ ........ ....... ...... ...... ...... ..... ..... .... ... . ....... .... ............. ...... l:l J ........................ ... ·1---------<f----+-- I ·o
:ii:: 30 +--+--+-+------af-+--+-+-+-+---1-+-+-+-+-+->-+-+-++->-++-t-++-f+-H+++<-++H-+t----+--+---+-+-----< D Procedure B ...................................................................................... ...... ..... ..... .... .................. ... ... ..... ... ......... ... ...... ......... .. . .. ·t-----+- --1··············· .............. ............ .
One-point Test 29 +--+-+-+----,1-+-+-+-+-+-1-+-+-+-+-+-f-+-+++l-++l++-f+H+H,-++H-+t---+--+---+-+-------1 1----,f--t--+- +········· ................................... ...... ..... ..... .... ................... ... ... ...... ... ......... ... ...... ......... .. . .. ·t------if---+-- t 28 +--+-+-......... 1-+-+-+-+-+-....,._+-+-................ ""-+-.................. u...+ ................. _____ +---+-+-------1 10 20 25 30 40 50 60 70 80 90 100
Number of Blows
~ Leighton ATTERBERG LIMITS
ASTM D4318
Project Name: CapRock/6th Avenue/GE Tested By: M. Vinet Date: 04/27/23 Project No. : 13877.001 Input By: M. Vinet Date: 04/27/23 Boring No.: LB-3 Checked By: M. Vinet
Sample No.: B-1 Depth (ft.) 0 - 5.0
Soil Identification: Clayey Sand (SC), Dark Brown.
TEST
NO.
Number of Blows [NJ
Wet Wt. of Soil + Cont. (g)
Dry Wt. of Soil + Cont. (g)
Wt. of Container (g)
Moisture Content(%) [Wn]
Liquid Limit
Plastic Limit
Plasticity Index
Classification
PLASTIC LIMIT LIQUID LIMIT
1 2 3 4
16 23 30
22.14 20.46 27.12 26.21 27.06
20.71 19.35 24.09 23.45 24.14
13.67 13.79 13.68 13.70 13.65
20.31 19.96 29.11 28.31 27.84
60 -r--------------,.---------, 28
20 8
CL
50 0::: 40
X
Q)
~ 30
For classification of fine-grained soils and fine-grained fraction of coarse-grained soils CH or OH
PI at "A" - Line = 0.73(LL-20) ~I _5_._84_~
One - Point Liquid Limit Calculation
10 0.121
LL =Wn(N/25)
PROCEDURES USED
D Wet Preparation
Multipoint - Wet
w Dry Preparation
Multipoint - Dry
w Procedure A
Multipoint Test
D Procedure B
One-point Test
MH or OH
0 ---..-----------------,.----.---
0 10 20 30 40 50 60 70 80 90 100
Liquid Limit (LL)
31 -r--.--..--,---,,---,-..,......,---,-'T'"'"T'..,....,...,....,..T"T""l"'T"'T'T'T"T"T"T"'l'.,..,..,..rT'T'TT'T"T'TT"T'TT"-----r--""T'""----.-T""""""'1 >----,f----+--+-- + ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ..... ... ........ , .............. , .. .. , ·1----------<f----+-- I 30 +--+--+--t-+--+--+--i--+-+-+-+-+-+-+-+-+-t-+++++++++++t-+++++++-++++-----+---+----+-+------< ....................... ...... :,,'"::::: ...................................... ...... ...... .............. ........... .... ............. ...... .................... ......... ... ·1---------<f----+-- I ""'----1 .__ ~ 29 +--+--+--t-+--+---+->sl--+-+-+-+-+-+-+-+-+-t-+++++++++++t-+++++++-++++-----+---+----+-+------< ~ r----- ,
-
$ ......... ........ ........ ...... ...... "~ .... ···~ ~;: ... . ............ ... ... ....... ......... ... ............... .... ·1----------lf---+-- t C:
o 28 +--+--+--t-+-+--+---1-+-+-+++++¼-+-'t-sr++++++++++t-++++++++++t----+--+----t-+----l (.)
~ 1----,f--t--+- +········· ................................... ...... ..... ..... .... ................... ... ... ...... ... .. ..... ... ...... ......... . . . .. ·1----------lf---+-- t ::I
-ti) ·o 27 +--+--+--t-+--+--+--i--+-+-+-+-+-+-+-+-+-t-+++++++++++t-+++++++-++++-----+---+----+-+------< :ii::
>----,f----+--+-- + ...................................... , ..... , .... , ......... , .... ........... , ... , ............ , ..... ... ........ , .............. , .. .. , ·1----------<f----+-- I 26 +--+--+--t-+--+--+--i--+-+-+-+-+-+-+-+-+-t-+++++++++++t-+++++++-++++-----+---+----+-+------< ·········· 1 ...... ······· 1111 ................ ............ .............. ·· 1 ....... ··· 11 11 .... 1111 ... . 25 __ ...._....._ ......... _._ ......... _._-"-+ ................................. +,i-l, ................ '-+"-', ................. ----+------+-----1 10 20 25 30
Number of Blows
40 50 60 70 80 90 100
~ Leighton EXPANSION INDEX of SOILS
ASTM D 4829
Project Name: CapRock/6th Avenue/GE
Project No. : 13877.001
Boring No.: LB-3
Sample No. : B-1
Sample Description: Clayey Sand (SC), Dark Brown.
Dry Wt. of Soil + Cont. (gm.)
Wt. of Container No. (gm .)
Dry Wt. of Soil (gm.)
Weight Soil Retained on #4 Sieve
Percent Passing # 4
MOLDED SPECIMEN
Specimen Diameter (in .)
Specimen Height (in.)
Wt. Comp. Soil+ Mold (gm.)
Wt. of Mold (gm.)
Specific Gravity (Assumed)
Container No.
Wet Wt. of Soil + Cont. (gm.)
Dry Wt. of Soil+ Cont. (gm.)
Wt. of Container (gm.)
Moisture Content(%)
Wet Density (pcf)
Dry Density (pcf)
Void Ratio
Total Porosity
Pore Volume (cc)
Deoree of Saturation(%) f S measl
Tested By: M. Vinet
Checked By: M. Vinet
Depth: 0 - 5.0
Location: N/A
4016.2
0.0 4016.2
256.2
93.6 Before Test
4.01 1.0000
572.0
190.7
2.70 12
577.6
544.3
277.6
12.5 115.0
102.2
0.649
0.394
81 .5
52.0 After Test
4.01 1.0243
606.4
190.7
2.70 12
606.4
338.9
190.7
22.6 122.4
99.8 0.689
0.408
86.5 88.8
SPECIMEN INUNDATION in distilled water for the period of 24 h or expansion rate< 0.0002 in./h.
Date Time
I
Pressure
I
Elapsed Time
I (psi) (min .)
4/26/23 10:30 I 1.0 I 0 I
4/26/23 10:40 I 1.0 I 10 I
Add Distilled Water to the Specimen
4/27/23 8:00 I 1.0 I 1280 I
4/27/23 9:00 I 1.0 I 1340 I
Expansion Index (El meas) = ((Final Rdg - Initial Rdg) / Initial Thick.) x 1000 Expansion Index ( Report) = Nearest Whole Number or Zero (0) if Initial Height is > than Final Heigh Date: 4/26/23
Date: 4/27/23
Dial Readings
(in.)
0.5000
0.5000
0.5243
0.5243
24.3 24
Rev. 03-08
~ Leighton One-Dimensional Swell or Settlement
Potential of Cohesive Soils
(ASTM D 4546) - Method 'B'
Project Name: CaeRock/6th Avenue/GE Tested By: M. Vinet Date:
Project No.: 13877.001 Checked By: M. Vinet Date:
Boring No.: LB-1 Sample Type: IN SITU
Sample No.: R-3 Depth (ft.) 7.5
Sample Description: Silty Sand (SM), Yellowish Brown.
Source and Type of Water Used for Inundation: Arrowhead ( Distilled ) ** Note: Loading After Wetting (Inundation) not Performed Using this Test Method.
Initial Dry Density (pcf): 97.3 Final Dry Density (pcf):
Initial Moisture(%): 17.1 Final Moisture (%) :
Initial Height (in.): 1.0000 Initial Void ratio:
Initial Dial Reading (in): 0.0000 Specific Gravity (assumed):
Inside Diameter of Rinq (in): 2.416 Initial Deqree of Saturation(%) Apparent Load Swell(+)
Pressure (p) Final Reading Thickness Compliance Settlement(-) Void Ratio (ksf) (in) (in) (%) % of Sample Thickness
0.525 0.0079 0.9921 0.00 -0.79 0.7179
1.013 0.0178 0.9822 0.00 -1.78 0.7008
H2O 0.0287 0.9713 0.00 -2.87 0.6819
Percent Swell / Settlement After Inundation = -1.11
5.00 4.00
3.00 2.00
-;,F. 1.00
C
o 0.00 ~
E .E -1.00 Q)
o -2.00
-3.00
-4.00
-5.00
0.010
I Deformation % - Log Pressure Curve I
(
I Inundate With
I Distilled Water
0.100
.. , ... "" ' - I
1.000
Log Pressure (ksf)
10.000
4/26/23
4/27/23
100.2
23.6 0.7316
2.70 63.2
Corrected
Deformation
(%)
-0.79
-1.78
-2.87
Rev. 01 -10
~ Leighton TESTS for SULFATE CONTENT
CHLORIDE CONTENT and pH of SOILS
Project Name: CapRock/6th Avenue/GE
Project No. : 13877.001
----------
Boring No.
Sample No.
Sample Depth (ft)
Soil Identification:
Wet Weight of Soil + Container (g)
Dry Weight of Soil + Container (g)
Weight of Container (g)
Moisture Content(%)
Weight of Soaked Soil (g)
SULFATE CONTENT, Hach Kit Method
Dilution : 1
Water Fraction (ml)
Tube Reading
PPM Sulfate
% Sulfate
LB-3
B-1
0 - 5.0
Clayey Sand
(SC)
100.0
100.0
0.0 0.0
100.0
3 25
60 180
0.0180
CHLORIDE CONTENT, DOT California Test 422
ml of Extract For Titration (B) 30
ml of AgNO3 Soln. Used in Titration (C) 0.6
PPM of Chloride (C -0.2) * 100 * 30 / B 40
PPM of Chloride, Dry Wt. Basis 40
7.60 21.0
Tested By:
Data Input By:
M. Vinet Date: 04/27/23
M. Vinet Date: 04/27/23
~ Leighton SOIL RESISTIVITY TEST
DOT CA TEST 643
Project Name: CapRock/6th Avenue/GE Tested By : M. Vinet Date: 04/27/23 Project No. : 13877.001 Data Input By: M. Vinet Date: 04/27/23 Boring No.: LB-3 Depth (ft.) : 0 - 5.0 ------- ------
Sample No. : B-1
-------
Soil Identification:* Clayey Sand (SC)
*California Test 643 requires soil specimens to consist only of portions of samples passing through the No. 8 US Standard Sieve before resistivity testing. Therefore, this test method may not be representative for coarser materials.
Water Adjusted
Specimen Added (ml) Moisture
No. Content (Wa) (MC)
1 50 10.00
2 83 16.60
3 116 23.20
4 149 29.80
5 Min. Resistivity Moisture Content
(ohm-cm) (%)
DOT CA Test 643
3400
16000
14000
12000
-
E
0 I
E 10000
.c
0 -
~ 8000
>
:;;
1/)
~ 6000
0:::
~ 4000
2000
0 0.0
26.0 5.0
Resistance Soil Moisture Content (%) (MCi) 0.00
Reading Resistivity Wet Wt. of Soil + Cont. (g) 100.00
(ohm) (ohm-cm) Dry Wt. of Soil + Cont. (g) 100.00
14000 14000 Wt. of Container (g) 0.00
5700 5700 Container No. A
3600 3600 Initial Soil Wt. (g) (Wt) 500.00
3600 3600 Box Constant 1.000
MC =((( 1 +Mei/ lOO)x(Wa/Wt + 1) )-1 )x 100
Sulfate Content Chloride Content Soil pH
(ppm) (ppm) pH I Temp. (
0 C)
Hach Kit DOT CA Test 422 DOT CA Test 643
180 40 7.60 I 21.0
\
'
\
\
\
\
\
\
\
I\
I\ Minimum resistivity
.. read here --,
" I/
1--......
- I
~ - - ' .
-
10.0 15.0 20.0 25.0 30.0 35.0
Moisture Content (%)
APPENDIX D
SUMMARY OF SEISMIC HAZARD ANALYSIS
~ Leighton
a verdantas company
U.S. Geological Survey- Earthquake Hazards Program
Unified Hazard Tool
Please do not use this tool to obtain ground motion parameter values for the design code reference documents covered by the U.S. Seismic Design MaP-S web tools (e.g., the International Building Code and the ASCE 7 or 41 Standard). The values returned by the two applications are not identical.
Please also see the new USGS Earthguake Hazard Toolbox for access to the most recent NSHMs for the conterminous U.S. and Hawaii.
A Input
Edition Spectral Period
._I _o_y_n_a_m_ic_:_c_o_n_te_r_m_i_n_o_us_u_.s_. _2_01_4_(_u_. _· . __ __.I I Peak Ground Acceleration Latitude Time Horizon
Decimal degrees Return period in years
~I _34_._o3_6_1 ___________ ~11 2475
Longitude
Decimal degrees, negative values for western longitudes 1 -117.9785
Site Class
259 m/s (Site class D)
A Hazard Curve
Hazard Curves Uniform Hazard Response Spectrum
3.0 le+0
le-1 Q/ 2.S
u
<::
Q/ le-2 "tJ
Q/
Q/ le-3 !;! 2.0
w
0 le-4
>, - Time Horizon 2475 years u
<:: le-5 ....,_ Pe ak Ground Acceleration Q/
:, - 0.10 Second Spectral Acceleration
LS
C" le-6 - 0.20 Second Spectral Acceleration ~ LL ....,._ 0.30 Second Spectral Acceleration 1.0 '" le-7 .....,_ 0.50 Second Spectral Acceleration
:, ....,.. 0. 75 Second Spectral Acceleration <::
<:: le-8 ......,_ 1.00 Second Spectral Acceleration <( ....,._ 2.00 Second Spectral Acceleration 0.S le-9 -+- 3.00 Second Spectral Acceleration
....,.. 4.00 Second Spectral Acceleration
....,._ 5.00 Second Spectral Acceleration 0.0
le-10
le-2 le-1 le+0 0.0 0.S 1.0 1.5 2.0 2.S 3.0 3.5 4.0 4.5 S.0 Ground Motion (g) Spectral Period (s)
Component Curves for Peak Ground Acceleration
le+0
le-1
Q/ le-2 u
<::
Q/ le-3 "tJ
Q/
Q/ le-4 u
il:i le-5
0 le-6 >,
u
<:: le-7 Q/
:,
C" le-8
~ LL le-9
'" :, le-10 <::
<:: - Time Horizon 2475 years <( le-11 .....,. System
le-12 .....,. Grid
......,_ Interface
le-13 ....,._ Fault
le-2 le-1 le+0
Ground Motion (g)
View Raw Data
A Deaggregation
Component
Total
Lf)
N
• •
.. • ••
•
!s
.• •··
•
•
.. • • ••
■ E = (- 00 • • -2.5)
■ E=[-2.5 .. -2)
■ E=[-2 .. -1.5)
0 E=[-1.5 .. -1)
0 E = [-1.. -0.5)
0 E=[-0.5 .. 0)
0 E= [0 .. 0.5)
0 E= [0.5 .. 1)
■ E= [l .. 1.5)
■ E=[l.5 .. 2)
■ E=[2 .. 2.5)
E=[2 5 .. +oo)
Summary statistics for, Deaggregation: Total
Deaggregation targets
Return period: 2475 yrs
Exceed a nee rate: 0.0004040404 y, 1
PGAground motion: 0.79023608 g
Totals
Binned: 100 %
Residual: O %
Trace: 0.05 %
Mode (largest m -r bin)
m: 6.27
r: 7.86 km
Eo: 1.44 0
Contribution: 15.87 %
Discretization
r: min= 0.0, max= 1000.0, /:J. = 20.0 km
m: min= 4.4, max= 9.4, /:J. = 0.2
E: min= -3.0, max= 3.0, /:J. = 0.5 a
Recovered targets
Return period: 2922.3872 yrs
Exceedance rate: 0.00034218601 y, 1
Mean ( over all sources)
m: 6.86
r: 12.08 km
Eo: 1.48 a
Mode (largest m-r-Eo bin)
m: 7.74
r: 8 km
Eo: 0.76 0
Contribution: 6.46 %
Epsilon keys
EO: [- 00 •• -2.5)
El: [-2.5 .. -2.0)
E2: [-2.0 .. -1.5)
E3: [-1.5 .. -1.0)
E4: [-1.0 .. -0.5)
ES: [-0.5 .. 0.0)
E6: [0.0 .. 0.5)
E7: [0.5 .. 1.0)
ES: [1.0 .. 1.5)
E9: [1.5 .. 2.0)
£10: [2.0 .. 2.5)
Ell: [2.5 .. +00 ]
Deaggregation Contributors
Source Set I+ Source Type r m Eo Ion lat az %
UC33brAvg_FM31 System 42.15
Whittier a It 1 [7J 6.57 6.67 1.16 118.009°W 33.983°N 205.29 10.38 Puente Hills [lJ 9.71 7.37 0.85 117.978°W 33.944°N 179.63 6.88 Whittier a It 1 [6J 6.90 6.39 1.28 117.990°W 33.975°N 189.03 3.24 San Jose [2J 9.15 7.05 1.10 117.881°W 34.043°N 85.12 3.00 Compton [lJ 18.14 7.27 1.39 118.161°W 33.764°N 209.18 2.76 Elysian Park (Upper) [OJ 12.54 6.51 2.04 118.097°W 34.077°N 292.71 2.63 Raymond [OJ 13.75 7.30 1.74 118.046°W 34.145°N 332.84 2.49 Sierra Madre [2J 14.32 7.74 1.56 117.942°W 34.161°N 13.57 1.78 San Andreas (Mojave S) [llJ 45.73 8.08 2.47 117.756°W 34.404°N 26.45 1.68 UC33brAvg_FM32 System 39.10
Whittier a It 2 [6J 6.76 7.19 1.03 118.010°W 33.983°N 205.96 8.97 Whittier a It 2 [5J 7.29 7.16 1.03 117.982°W 33.972°N 182.67 4.53 Compton [lJ 18.14 7.33 1.37 118.161°W 33.764°N 209.18 2.95 San Jose [2J 9.15 7.03 1.11 117.881°W 34.043°N 85.12 2.93 Puente Hills (Santa Fe Springs) [OJ 9.80 6.92 1.09 118.023°W 33.950°N 203.46 2.82 Raymond [OJ 13.75 7.29 1.75 118.046°W 34.145°N 332.84 2.62 Puente Hills (LA) [OJ 12.45 7.16 1.43 118.116°W 33.990°N 248.22 2.48 Sierra Madre [2J 14.32 7.77 1.55 117.942°W 34.161°N 13.57 1.80 San Andreas (Mojave S) [llJ 45.73 8.08 2.47 117.756°W 34.404°N 26.45 1.68 Richfield [lJ 14.06 6.17 1.85 117.870°W 33.882°N 149.70 1.57 Elysian Park (Upper) [OJ 12.54 6.82 1.87 118.097°W 34.077°N 292.71 1.42 Puente Hills (Coyote Hills) [lJ 10.26 7.12 0.87 118.024°W 33.910°N 196.74 1.38 UC33brAvg_FM32 (opt) Grid 9.51
PointSourceFinite: -117.978, 34.077 6.82 5.64 1.65 117.978°W 34.077°N 0.00 2.07 PointSourceFinite: -117.978, 34.077 6.82 5.64 1.65 117.978°W 34.077°N 0.00 2.07 UC33brAvg_FM31 (opt) Grid 9.24
PointSourceFinite: -117.978, 34.077 6.88 5.59 1.68 117.978°W 34.077°N 0.00 2.00 PointSourceFinite: -117.978, 34.077 6.88 5.59 1.68 117.978°W 34.077°N 0.00 2.00
0 .. , ....! i ~ ;
OSHPD :;; ~
CALIFORNIA
Latitude, Longitude: 34.0361, -117.9785
C, Industry West Duke's '
C, So Cal Industries
'
Reta i IThera py94
9C1
FX Cabinets Warehouse /
Heating &ft
Cooling Supply T
Go gle
Frontline Freight C, Shellq
Date
Design Code Reference Document
Risk Category
Site Class
Type Value
Ss 1.753
S1 0.63
SMs 1.753
SM1 null -See Section 11.4.8
Sos 1.169
So1 null -See Section 11.4.8
Type Value
soc null -See Section 11.4.8
Fa
Fv null -See Section 11.4.8
PGA 0.748
FPGA 1.1
PGAM 0.823
TL 8
SsRT 1.753
SsUH 1.934
SsD 2.297
S1RT 0.63
S1UH 0.698
S1D 0.734
PGAd 0.919
PGAuH 0.748
CRs 0.907
CR1 0.902
Cv 1.451
Description
4/24/2023, 2:50:02 PM
ASCE7-16
II
D - Stiff Soil
MCER ground motion. (for 0.2 second period)
Description
MCER ground motion. (for 1.0s period)
Site-modified spectral acceleration value
Site-modified spectral acceleration value
Numeric seismic design value at 0.2 second SA
Numeric seismic design value at 1.0 second SA
Seismic design category
Site amplification factor at 0.2 second
Site amplification factor at 1.0 second
MCEG peak ground acceleration
Site amplification factor at PGA
Site modified peak ground acceleration
Long-period transition period in seconds
Probabilistic risk-targeted ground motion. (0.2 second) Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value. (0.2 second) Probabilistic risk-targeted ground motion. (1.0 second) Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration.
Factored deterministic acceleration value. (1 .0 second) Factored deterministic acceleration value. (Peak Ground Acceleration) Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration Mapped value of the risk coefficient at short periods
Mapped value of the risk coefficient at a period of 1 s Vertical coefficient
Map data ©2023
DISCLAIMER
While the information presented on this website is believed to be correct, SEAOC /OSHPD and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the search results of this website.
Liquefaction Susceptibility Analysis: SPT Method
Youd and Idriss (2001), Martin and Lew (1999)
Leighton
Description: 110 6th Avenue Industry Warehouse; Case 4; PGAm 0.823; design GW 33; Overex./scarify 8 Project No.: 13877.001
Apr2023
General Boring Information:
Boring
No.
LB-1
LB-2
LB-3
LB-4
Leighton
Existing Design
GW GW
Depth (ft)
65 65
65 65
Depth (ft)
33 33
33 33
Design Overex.
Fill Height depth bgs
(ft) (ft)
8 8
8 8
Ground
Surface
Elev (ft)
290
290 k;
290 IL'Jl
289 L'J6
Boring Location
Coordinates
X (ft) Y (ft)
580.64 71 .294
288.15 268.71
402.75 -104.2
68.841 80.603
General Parameters:
amax = 0.82g
Mw = 7.7
MSF eq: 1
MSF = 0.93
Hammer Efficiency= 84
CE= 1.40
Cs= 1
C8 for SPT? TRUE
Unlined, but room for liner
Rod Stickup (feet)= 3
Ring sample correction= 0.65
Summary of Liquefaction Susceptibility Analysis: SPT Method Liquefaction Method: Youd and Idriss (2001). Seismic Settlement Method: Tokimatsu and Seed (1987) and Martin and Lew (1999).
Boring
No.
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
L~1
LB-2
LB-2
LB-2
LB-2
LB-2
LB-2
LB-2
LB-2
LB-3
LB-3
LB-3
LB-3
LB-3
LB-3
LB-3
LB-4
LB-4
LB-4
LB-4
LB-4
Leighton
Project: 110 6th Avenue Industry Warehouse; Case 4; PGAm 0.823; design GW 33; Overex./scarify 8 Project No.: 13877.001
Approx Plasticity
Layer ("n"=non
Approx. Layer SPT Thick- susc. to
Depth Depth ness liq.)
(fl) (fl)
O to 3.8 2.5
3.8 to 6.3 5
6.3 to 8.0 7.5
8.0 to 8.8 7.5
8.8 to 12.5 10
12.5 to 17.5 15
17.5 to 22.5 20
22.5 to 27.5 25
27.5 to 32.5 30
32.5 to 33.0 35
33.0 to 37.5 35
37.5 to 42.5 40
42.5 to 47.5 45
47.5 to 52.0 50
O to 3.8 2.5
3.8 to 6.3 5
6.3 to 8.0 7.5
8.0 to 8.8 7.5
8.8 to 12.5 10
12.5 to 17.5 15
17.5 to 22.5 20
22.5 to 27.0 25
O to 6.3 5
6.3 to 8.0 7.5
8.0 to 8.8 7.5
8.8 to 12.5 10
12.5 to 17.5 15
17.5 to 22.5 20
22.5 to 27.0 25
O to 3.8 2.5
3.8 to 6.3 5
6.3 to 8.0 7.5
8.0 to 8.8 7.5
8.8 to 12.5 10
(fl)
as
~5
1B
QB
as
~o
~o
~o
~o
Q5
~5
~o
~o
~5
as
~5
1B
QB
as
~o
~o
~5
6.3 1.8
0.8 3.8
5.0 5.0
4.5 3.8
2.5 1.8
0.8 3.8
OX
OX
OX
OX
OX
OX
OX
OX
OX
OX
OX
Estimated
Fines Cont Yt
Nm
or B
Sampler
Type
(enter 2 if
mod CA
Ring)
(%) (pcf) (blows/ft)
30 30
15 15
~
~
20 I!!.
5 5
5 ~
§1_
1!!.
15 15
15 15
5 30
15 35
65 30
30 ~
25 15
10 20
15 10
10 ~
120 50
120 50
120 50
120 12
120 22
120 9
120 22
120 7
120 69
120 32
120 32
120 21
120 9
120 41
1W ~
1W ~
1W ~
1W ~
120 31
1W W
120 14
1W ~
1W ~
1W ~
1W ~
1W ~
1W ~
120 10
120 19
1W ~
1W ~
1W ~
1W ~
1W ll
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 2
Exist Design
Nm
(corrected
for Cs and
Cs ring->SPT) crvo' (N 1 )oo (N 1 )socs CRR,., crvo' CSR,.s CSRM
1.3 1.3
1.3 1.13
1.1 1.3
(blows/fl) (psi)
65.0 65.0
65.0 7.8
14.3 10.2
14.3 7.7
44.9 41 .6
300 116.0
600 116.0
900 110.9
900 13.3
1200 22.4
1800 13.0
2400 17.7
3000 8.5
3600 47.8
4200 41 .1
(psi)
138.6 >Range 300 0.53
138.6 >Range 600 0.53
118.7 >Range 900 0.53
16.4 0.175 900 0.53
31 .9 >Range 1200 0.52
19.8 0.212 1800 0.52
22.8 0.253 2400 0.51
15.3 0.163 3000 0.50
47.8 >Range 3600 0.50
41 .1 >Range 4075.2 0.49
1.3 41 .6 4200 41 .1 41 .1 >Range 4075.2 0.49
13.7 4800 12.6 20.1 0.217 4363.2 0.50
1.1 9.9 5400 8.6 15.3 0.164 4651 .2 0.50
1.3 1.3
1.3 26. 7 6000 22.0 26. 7 0.330 4939.2 0.50
65.0 300 116.0 124.1 >Range 300 0.53
65.0 600 116.0 124.1 >Range 600 0.53
65.0 900 110.9 118.7 >Range 900 0.53
18.2 900 31 .0 35.0 >Range 900 0.53
20.2 1200 31 .6 31 .6 >Range 1200 0.52
13.0 1800 16.7 23.9 0.272 1800 0.52
1.21 16.9 2400 21 .0 24.5 0.283 2400 0.51
1.3 1.3
19.5 3000 21 .6
65.0 65.0
16.3 19.5
16.3 600 116.0
900 110.9
900 27.7
1200 30.6
1800 20.8
31 .0 >Range 3000 0.50
144.2 >Range 600
132.7 >Range 900
36. 7 >Range 900
41 .7 >Range 1200
27.5 0.353 1800
0.53 0.53
0.53 0.52
0.52 1.14 11.4 2400 14.2 17.3 0.184 2400 0.51
1.3 1.3
1.3 12.4 3000 13.7 14.9 0.159 3000 0.50
65.0 65.0
65.0 19.5
300 116.0 128.9 >Range 300
600 116.0 124.1 >Range 600
900 110.9 114.2 >Range 900
900 33.3 34.9 >Range 900
0.53 0.53
0.53 0.53
17.6 1200 27.5 38.1 >Range 1200 0.52
0.57 0.57
0.56 0.56
0.56 0.55
0.55 0.54
0.53 0.52
0.52 0.53
0.54 0.53
0.57 0.57
0.56 0.56
0.56 0.55
0.55 0.54
0.57 0.56
0.56 0.56
0.55 0.55
0.54 0.57
0.57 0.56
0.56 0.56
Liquefaction (N, )socs
Factor of (for Settle--
Safety
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
0.41 0.30
0.62 Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
Nonliq
ment)
(blows/fl)
138.6
138.6
118.7
16.4 31 .9
19.8 22.8
15.3 47.8
41 .1
41 .1
14.6 12.6
23.0 124.1
124.1
118.7
35.0 31 .6
23.9 24.5
31 .0
144.2
132.7
36.7 41 .7
27.5 17.3
14.9 128.9
124.1
114.2
34.9 38.1
Dry Sand Sat Sand
Strain(%) Strain(%)
(Toki Seed (Toki Seed
87) 87)
(%)
0.00 0.00
0.00 1.06
0.31 1.06
0.85 1.72
0.05 0.06
0.00 0.00
0.00 0.19
0.31 0.53
0.80 0.48
0.00 0.00
0.18 0.08
0.43 1.40
2.43 0.00
0.00 0.00
0.19 0.27
(%)
1.94 2.21
1.4 Seismic
Sett. of
Layer
(in.)
0.00 0.00
0.00 0.10
0.14 0.64
0.51 1.03
0.03 0.00
0.00 1.16
1.33 0.76
QOO
QOO
QOO
QW
Q14
Q~
Q~
QW
0.00 0.00
0.02 0.04
0.26 0.84
1.31 0.00
0.00 0.00
0.02 0.12
Leighton
Cummulative
Seismic
Settlement
(in.)
~7
~7
~7
~7
~6
~5
~8
~3
a3
a2
a2
a2
~1
QB
1.2 1.2
1.2 1.2
1.2 1.1
0.7 0.3
2.5 2.5
2.5 2.4
2.4 2.1
1.3 2.3
2.3 2.3
2.3 2.3
Approx Sampler
L Plasticity Type Nm Liquefaction (N1)aocs Dry Sand Sat Sand Seismic Cummulative a_yer ("n"=non (enter 2 if (corrected Strain(%) Strain(%) Boring Approx. Layer SPT Thick- susc. to Estimated Nm mod CA for Cs and Exist Design Factor of (for Settle- (Toki Seed (Toki Seed Sett. of Seismic No. Depth Depth ness liq.) Fines Cont Yt or B Ring) Cs ring->SPT) crvo' (N1)00 (N1)aocs CRR7_5 crvo' CSR7_5 CSRM Safety ment) 87) 87) Layer Settlement (fl) (fl) (fl) (%) (pcf) (blows/ft) (blows/ft) (psi) (psi) (blows/fl) (%) (%) (in.) (in.) LB-4 12.5 to 17.5 15 5.0 §i 120 5 1 1.1 5.5 1800 7.0 13.5 0. 145 1800 0.52 0.55 Nonliq 13.5 1.96 1.18 2.2 LB-4 17.5 to 22.5 20 5.0 30 120 22 2 1 14.3 2400 17.7 25.2 0.296 2400 0.51 0.55 Nonliq 25.2 0.78 0.47 1.0 LB-4 22.5 to 27.0 25 4.5 10 120 17 1 1.23 20.9 3000 23.2 24.6 0.284 3000 0.50 0.54 Nonliq 24.6 0.98 0.53 0.5 Leighton Page 2 of 2
Surface Manifestations of Liquefaction and Liquefaction Bearing Capacity Analys is 110 6th Avenue Industry Warehouse; Case 4; PGAm 0.823; design GW 33; Overex./scarify 8 13877.001
Leighton
Ishihara, 1995, Surface Manifestisatio ns of Liquefactio n Analysis:
Boring New Fill
No.
LB-1 0 2 37.5 52.0
LB-2 0 2 27.0
LB-3 0 2 27.0
LB-4 0 2 27.0
1a-----.-----.------,---...---.--~-,
I Ishihara, Figure 10
16 Conditions of liquefied
~ma9;J soil profile causing .':5# damage to structures 14f N~mo ~ 'c'!l!b-f<>11orlnlions E 9 embedded lo a depth - or about 8 m M
::c 1:2•·
I.
., Om 2m
'i,.i' ')
~ 11 } {
. i 31ftc;, I ~
>,
.21J)o,•
:, _ ._:. ~ ,'.. :~ .:.• :: g'll
0 ~ <1
41 j
.!:I
J:.
....
4m
"'i
•-- ••I
{,
ij
:_:-
6m
')
}f:
Bm
")
t~
j
-;,.
f *
;;"} ♦
2 4 €; 8 10 -~1~2
Thickness of unlfquefioble surface layer, H, (ml
37.5 27.0
27.0 27.0
5!
}
I
J
j
0 I
Struct Damage/
Surface
Manifestations?
Ishihara, 1995
14.5 11.4 4.4 no
8.2 no
8.2 no
8.2 no
Footing Depth= 2 ft
0.61 m
Ill
1n.r
Ht~
TNduMSJ al unAquefta.ble aurlace la)'ff, HI
Leighton
Amount of Or, Amount
New Fill of Overex.
needed to
miti ate ft
0 0
0 0
0 0
0 0
Karamitros et al., 201 3, Liqufaction Bearing Capacity: Juang (2005) based on Iwasaki (1 982), as presented in Tonkin & Taylo r (2013},
Liquefactio n Potent ial Index (LPI):
In order to achieve critical thickness of
Assumed Non-liquefiable upper clay crust (where
additional thickness does not further
10 10
10 10
4 4
4 4
increase FSli
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
References:
0.0 0.0
0.0 0.0
0.0 0.0
0.0 0.0
I
Risk of Liquefaction
LPI = Damage Based on
Sum[F1'W(z)'dz] LPI
0.0 0.0
0.0 0.0
LPI ra nge:
LPl=0
0<LPl<=S
5< LPl<=15
LPl>15
Very Low
Very Low
Very Low
Very Low
Liquefact io n Risk:
Very low
Low
High
Very High
Ishihara, K., 1995, Effects of At-Depth Liquefaction on Embedded Foundations During Earthquakes, Proceedings of 11th Asian Regional Conference on Soil Mechanics and Foundation Engineering, Vol. 2, 1995.
Iwasaki, T., Arakawa, T., and Tokida, K., 1982, Simplifed Procedures for Assessing Soil Liquefaction During Earthquakes Proc. Conference on Soil Dynamics and Earthquake Engineering. Southampton, 925-939
Juang, C.H, Yang, S.H, Yuan, H., and Fang, S.Y., 2005, Liquefaction in the Chi-Chi earthquake - effect of fines and capping non-liquefiable layers Journal of the Japanese Geotechnical Society of Soils and Foundations, Vol. 45 No. 6 pp 89-101 Karamitros, Bouckovalas, Chaloulos, and Andrianopoulos, 2013, Numerical analysis of liquefaction-induced bearing capacity degradation of shallow foundations on a two-layered soil profile, Soil Dynamics and Earthquake Engineering, Vol 44.
Tonkin & Taylor Ltd, 2013, Liquefaction Vulnerability Study, Earthquake Commission, T&T Ref
APPENDIX E
GENERAL EARTHWORK AND GRADING SPECIFICATIONS
~ Leighton
a verdantas company
LEIGHTON CONSULTING, INC.
GENERAL EARTHWORK AND GRADING SPECIFICATIONS FOR ROUGH GRADING Table of Contents
Section Page
1.0 GENERAL 1
1.1 Intent 1
1.2 The Geotechnical Consultant of Record 1
1.3 The Earthwork Contractor 2
2.0 PREPARATION OF AREAS TO BE FILLED 2
2.1 Clearing and Grubbing 2
2.2 Processing 3
2.3 Overexcavation 3
2.4 Benching 3
2.5 Evaluation/ Acceptance of Fill Areas 3
3.0 FILL MATERIAL 4
3.1 General 4
3.2 Oversize 4
3.3 Import 4
4.0 FILL PLACEMENT AND COMPACTION 4
4.1 Fill Layers 4
4.2 Fill Moisture Conditioning 4
4.3 Compaction of Fill 5
4.4 Compaction of Fill Slopes 5
4.5 Compaction Testing 5
4.6 Frequency of Compaction Testing 5
4.7 Compaction Test Locations 5
5.0 SUBDRAIN INSTALLATION 6
6.0 EXCAVATION 6
7.0 TRENCH BACKFILLS 6
7.1 Safety 6
7.2 Bedding and Backfill 6
7.3 Lift Thickness 6
7.4 Observation and Testing 6
1 3030.495
LEIGHTON CONSULTING, INC.
General Earthwork and Grading Specifications
1.0 General
3030.495
1.1 Intent: These General Earthwork and Grading Specifications are for the grading and earthwork shown on the approved grading plan( s) and/ or indicated in the geotechnical report(s). These Specifications are a part of the recommendations contained in the geotechnical report(s). In case of conflict, the specific recommendations in the geotechnical report shall supersede these more general Specifications. Observations of the earthwork by the project Geotechnical Consultant during the course of grading may result in new or revised recommendations that could supersede these specifications or the recommendations in the geotechnical report(s).
1.2 The Geotechnical Consultant of Record: Prior to commencement of work, the owner shall employ the Geotechnical Consultant of Record (Geotechnical Consultant). The Geotechnical Consultants shall be responsible for reviewing the approved geotechnical report( s) and accepting the adequacy of the preliminary geotechnical findings, conclusions, and recommendations pnor to the commencement of the grading.
Prior to commencement of grading, the Geotechnical Consultant shall review the "work plan" prepared by the Earthwork Contractor (Contractor) and schedule sufficient personnel to perform the appropriate level of observation, mapping, and compaction testing.
During the grading and earthwork operations, the Geotechnical Consultant shall observe, map, and document the subsurface exposures to verify the geotechnical design assumptions. If the observed conditions are found to be significantly different than the interpreted assumptions during the design phase, the Geotechnical Consultant shall inform the owner, recommend appropriate changes in design to accommodate the observed conditions, and notify the review agency where required. Subsurface areas to be geotechnically observed, mapped, elevations recorded, and/or tested include natural ground after it has been cleared for receiving fill but before fill is placed, bottoms of all "remedial removal" areas, all key bottoms, and benches made on sloping ground to receive fill.
The Geotechnical Consultant shall observe the moisture-conditioning and processing of the subgrade and fill materials and perform relative compaction testing of fill to determine the attained level of compaction. The Geotechnical Consultant shall provide the test results to the owner and the Contractor on a routine and frequent basis.
LEIGHTON CONSULTING, INC.
General Earthwork and Grading Specifications
1.3 The Earthwork Contractor: The Earthwork Contractor (Contractor) shall be qualified, experienced, and knowledgeable in earthwork logistics, preparation and processing of ground to receive fill, moisture-conditioning and processing of fill, and compacting fill. The Contractor shall review and accept the plans, geotechnical report(s), and these Specifications prior to commencement of grading. The Contractor shall be solely responsible for performing the grading in accordance with the plans and specifications.
The Contractor shall prepare and submit to the owner and the Geotechnical Consultant a work plan that indicates the sequence of earthwork grading, the number of "spreads" of work and the estimated quantities of daily earthwork contemplated for the site prior to commencement of grading. The Contractor shall inform the owner and the Geotechnical Consultant of changes in work schedules and updates to the work plan at least 24 hours in advance of such changes so that appropriate observations and tests can be planned and accomplished. The Contractor shall not assume that the Geotechnical Consultant is aware of all grading operations.
The Contractor shall have the sole responsibility to provide adequate equipment and methods to accomplish the earthwork in accordance with the applicable grading codes and agency ordinances, these Specifications, and the recommendations in the approved geotechnical report(s) and grading plan(s). If, in the opinion of the Geotechnical Consultant, unsatisfactory conditions, such as unsuitable soil, improper moisture condition, inadequate compaction, insufficient buttress key size, adverse weather, etc., are resulting in a quality of work less than required in these specifications, the Geotechnical Consultant shall reject the work and may recommend to the owner that construction be stopped until the conditions are rectified.
2.0 Preparation of Areas to be Filled
3030.495
2.1 Clearing and Grubbing: Vegetation, such as brush, grass, roots, and other deleterious material shall be sufficiently removed and properly disposed of in a method acceptable to the owner, governing agencies, and the Geotechnical Consultant.
The Geotechnical Consultant shall evaluate the extent of these removals depending on specific site conditions. Earth fill material shall not contain more than 1 percent of organic materials (by volume). No fill lift shall contain more than 5 percent of organic matter. Nesting of the organic materials shall not be allowed. 2
LEIGHTON CONSULTING, INC.
General Earthwork and Grading Specifications
3030.495
If potentially hazardous materials are encountered, the Contractor shall stop work in the affected area, and a hazardous material specialist shall be informed immediately for proper evaluation and handling of these materials prior to continuing to work in that area.
As presently defined by the State of California, most refined petroleum products (gasoline, diesel fuel, motor oil, grease, coolant, etc.) have chemical constituents that are considered to be hazardous waste. As such, the indiscriminate dumping or spillage of these fluids onto the ground may constitute a misdemeanor, punishable by fines and/or imprisonment, and shall not be allowed.
2.2 Processing: Existing ground that has been declared satisfactory for support of fill by the Geotechnical Consultant shall be scarified to a minimum depth of 6 inches.
Existing ground that is not satisfactory shall be overexcavated as specified in the following section. Scarification shall continue until soils are broken down and free of large clay lumps or clods and the working surface is reasonably uniform, flat, and free of uneven features that would inhibit uniform compaction.
2.3 Overexcavation: In addition to removals and overexcavations recommended in the approved geotechnical report(s) and the grading plan, soft, loose, dry, saturated, spongy, organic-rich, highly fractured or otherwise unsuitable ground shall be overexcavated to competent ground as evaluated by the Geotechnical Consultant during grading.
2.4 Benching: Where fills are to be placed on ground with slopes steeper than 5: 1 (horizontal to vertical units), the ground shall be stepped or benched. Please see the Standard Details for a graphic illustration. The lowest bench or key shall be a minimum of 15 feet wide and at least 2 feet deep, into competent material as evaluated by the Geotechnical Consultant. Other benches shall be excavated a minimum height of 4 feet into competent material or as otherwise recommended by the Geotechnical Consultant. Fill placed on ground sloping flatter than 5: 1 shall also be benched or otherwise overexcavated to provide a flat subgrade for the fill.
2.5 Evaluation/Acceptance of Fill Areas: All areas to receive fill, including removal and processed areas, key bottoms, and benches, shall be observed, mapped, elevations recorded, and/or tested prior to being accepted by the Geotechnical Consultant as suitable to receive fill. The Contractor shall obtain a written acceptance from the Geotechnical Consultant prior to fill placement. A licensed surveyor shall provide the survey control for determining elevations of processed areas, keys, and benches.
3
LEIGHTON CONSULTING, INC.
General Earthwork and Grading Specifications
3.0 Fill Material
3 .1 General: Material to be used as fill shall be essentially free of organic matter and other deleterious substances evaluated and accepted by the Geotechnical Consultant prior to placement. Soils of poor quality, such as those with unacceptable gradation, high expansion potential, or low strength shall be placed in areas acceptable to the Geotechnical Consultant or mixed with other soils to achieve satisfactory fill material.
3 .2 Oversize: Oversize material defined as rock, or other irreducible material with a maximum dimension greater than 8 inches, shall not be buried or placed in fill unless location, materials, and placement methods are specifically accepted by the Geotechnical Consultant. Placement operations shall be such that nesting of oversized material does not occur and such that oversize material is completely surrounded by compacted or densified fill. Oversize material shall not be placed within 10 vertical feet of finish grade or within 2 feet of future utilities or underground construction.
3 .3 Import: If importing of fill material is required for grading, proposed import material shall meet the requirements of Section 3 .1. The potential import source shall be given to the Geotechnical Consultant at least 48 hours (2 working days) before importing begins so that its suitability can be determined and appropriate tests performed.
4.0 Fill Placement and Compaction
3030.495
4.1 Fill Layers: Approved fill material shall be placed in areas prepared to receive fill (per Section 3.0) in near-horizontal layers not exceeding 8 inches in loose thickness.
The Geotechnical Consultant may accept thicker layers if testing indicates the grading procedures can adequately compact the thicker layers. Each layer shall be spread evenly and mixed thoroughly to attain relative uniformity of material and moisture throughout.
4.2 Fill Moisture Conditioning: Fill soils shall be watered, dried back, blended, and/or mixed, as necessary to attain a relatively uniform moisture content at or slightly over optimum. Maximum density and optimum soil moisture content tests shall be performed in accordance with the American Society of Testing and Materials (ASTM Test Method D1557-91).
4
LEIGHTON CONSULTING, INC.
General Earthwork and Grading Specifications
3030.495
4.3 Compaction of Fill: After each layer has been moisture-conditioned, mixed, and evenly spread, it shall be uniformly compacted to not less than 90 percent of maximum dry density (ASTM Test Method D1557-91). Compaction equipment shall be adequately sized and be either specifically designed for soil compaction or of proven reliability to efficiently achieve the specified level of compaction with uniformity.
4.4 Compaction of Fill Slopes: In addition to normal compaction procedures specified above, compaction of slopes shall be accomplished by backrolling of slopes with sheepsfoot rollers at increments of 3 to 4 feet in fill elevation, or by other methods producing satisfactory results acceptable to the Geotechnical Consultant. Upon completion of grading, relative compaction of the fill, out to the slope face, shall be at least 90 percent of maximum density per ASTM Test Method D1557-91.
4.5 Compaction Testing: Field tests for moisture content and relative compaction of the fill soils shall be performed by the Geotechnical Consultant. Location and frequency of tests shall be at the Consultant's discretion based on field conditions encountered. Compaction test locations will not necessarily be selected on a random basis. Test locations shall be selected to verify adequacy of compaction levels in areas that are judged to be prone to inadequate compaction (such as close to slope faces and at the fill/bedrock benches).
4.6 Frequency of Compaction Testing: Tests shall be taken at intervals not exceeding 2 feet in vertical rise and/or 1,000 cubic yards of compacted fill soils embankment.
In addition, as a guideline, at least one test shall be taken on slope faces for each 5,000 square feet of slope face and/or each 10 feet of vertical height of slope. The Contractor shall assure that fill construction is such that the testing schedule can be accomplished by the Geotechnical Consultant. The Contractor shall stop or slow down the earthwork construction if these minimum standards are not met.
4.7 Compaction Test Locations: The Geotechnical Consultant shall document the approximate elevation and horizontal coordinates of each test location. The Contractor shall coordinate with the project surveyor to assure that sufficient grade stakes are established so that the Geotechnical Consultant can determine the test locations with sufficient accuracy. At a minimum, two grade stakes within a horizontal distance of 100 feet and vertically less than 5 feet apart from potential test locations shall be provided.
5
LEIGHTON CONSULTING, INC.
General Earthwork and Grading Specifications
5. 0 Subdrain Installation
Subdrain systems shall be installed in accordance with the approved geotechnical report(s), the grading plan, and the Standard Details. The Geotechnical Consultant may recommend additional subdrains and/or changes in subdrain extent, location, grade, or material depending on conditions encountered during grading. All subdrains shall be surveyed by a land surveyor/civil engineer for line and grade after installation and prior to burial.
Sufficient time should be allowed by the Contractor for these surveys.
6.0 Excavation
Excavations, as well as over-excavation for remedial purposes, shall be evaluated by the Geotechnical Consultant during grading. Remedial removal depths shown on geotechnical plans are estimates only. The actual extent of removal shall be determined by the Geotechnical Consultant based on the field evaluation of exposed conditions during grading. Where fill-over-cut slopes are to be graded, the cut portion of the slope shall be made, evaluated, and accepted by the Geotechnical Consultant prior to placement of materials for construction of the fill portion of the slope, unless otherwise recommended by the Geotechnical Consultant.
7. 0 Trench Backfills
3030.495
7.1 Safety: The Contractor shall follow all OHSA and Cal/OSHA requirements for safety of trench excavations.
7.2 Bedding and Backfill: All bedding and backfill of utility trenches shall be done in accordance with the applicable provisions of Standard Specifications of Public Works Construction. Bedding material shall have a Sand Equivalent greater than 30 (SE> 30). The bedding shall be placed to 1 foot over the top of the conduit and densified by jetting. Backfill shall be placed and densified to a minimum of 90 percent of maximum from 1 foot above the top of the conduit to the surface.
The Geotechnical Consultant shall test the trench backfill for relative compaction.
At least one test should be made for every 300 feet of trench and 2 feet of fill. 7 .3 Lift Thickness: Lift thickness of trench backfill shall not exceed those allowed in the Standard Specifications of Public Works Construction unless the Contractor can demonstrate to the Geotechnical Consultant that the fill lift can be compacted to the minimum relative compaction by his alternative equipment and method.
7.4 Observation and Testing: The jetting of the bedding around the conduits shall be observed by the Geotechnical Consultant.
6
CIRCULATION DRAFT
City of Industry
South 6th Avenue Industry Redevelopment
Initial Study/Mitigated Negative Declaration
April 28, 2026
APPENDIX C
Phase I Environmental Site Assessment & Limited
Phase II Subsurface Investigation
PHASE I ENVIRONMENTAL SITE ASSESSMENT
MAKING A BETTER FUTURE FOR ALL THE COMMUNITIES WE TOUCH 100 - 190 South Sixth Avenue, 14404 -14436 East
Valley Boulevard
City of Industry, California 91746
PREPARED FOR:
CAPROCK PARTNERS
1300 DOVE STREET, SUITE 200
NEWPORT BEACH, CALIFORNIA 92660
HILLMANN PROJECT NUMBER: C3-10154
SEPTEMBER 18, 2024
September 18, 2024
Mr. Kelvin Koh
CapRock Partners
1300 Dove Street, Suite 200
Newport Beach, California 92660
RE: Phase I Environmental Site Assessment
100 - 190 South Sixth Avenue, 14404 -14436 East Valley Boulevard City of Industry, California 91746
Hillmann Project No: C3-10154
Dear Mr. Kelvin Koh:
Hillmann Consulting LLC has completed a Phase I Environmental Site Assessment at the above referenced site. This assessment was performed in conformance with the scope and limitations of ASTM E1527-21, which is the latest version of the E1527 standard published by the ASTM.
We appreciate the opportunity to provide environmental consulting services. If you have any questions concerning this report, or if we can assist you in any other matter, please contact our office at (714) 634-9500.
Sincerely,
Hillmann Consulting LLC
Kofi Bonner David Rutherford
Project Manager Technical Director
TABLE OF CONTENTS
1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Executive Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Findings, Opinions and Conclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.3 Business Environmental Risks / Non-ASTM Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.0 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.1 Purpose and Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.2 Property Location/Legal Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.3 Data Gaps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.4 ESA Report Component Dates/Viability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.5 User Reliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.6 Significant Assumptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.7 General Limitations and Exceptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.0 USER PROVIDED INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 Prior Environmental Reports/Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2 User Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4.0 RECORDS REVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.1 Environmental Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4.2 Historical Research . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5.0 INTERVIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
5.1 Interviews with Owners, Operators and Occupants . . . . . . . . . . . . . . . . . . . . . . . . 41
5.2 Interviews with State and/or Local Government Officials . . . . . . . . . . . . . . . . . . . 42
6.0 SITE RECONNAISSANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6.1 Methodology and Limiting Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6.2 General Site Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.3 Site Features and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.0 BUSINESS ENVIRONMENTAL RISKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.1 Asbestos-Containing Material (ACM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.2 Lead-Based Paint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.3 Radon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.4 Mold/Microbial Damage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.5 NWI Mapped Wetlands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
7.6 Lead in Drinking Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
8.0 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 APPENDIX A Site Diagram/Vicinity Map
APPENDIX B Site Photographs
APPENDIX C Questionnaires / User Provided Information
APPENDIX D Regulatory Records Documentation
APPENDIX E Historical Records Documentation
APPENDIX F Other Documents / Lab Results
APPENDIX G Project Personnel Qualifications
Phase I Environmental Site Assessment -i- C3-10154
LIST OF ACRONYMS/ABBREVIATIONS
Hillmann may use the following abbreviations and acronyms for common terminology described in our report. Not all abbreviations or acronyms may be applicable to this report:
AOC -Area of Concern
AST -Above Ground Storage Tank
ASTM -American Society for Testing Materials
BER -Business Environmental Risk
CERCLA -Comprehensive Environmental Response Compensation and Liability Act CERCLIS -Comprehensive Environmental Response Compensation and Liability Information System CESQG -Conditionally Exempt Small Quantity Generator
COC -Chemicals of Concern
CORRACTS -Corrective Action Sites
CREC -Controlled Recognized Environmental Condition
DEC -Department of Environmental Conservation
DEP -Department of Environmental Protection
DHS -Department of Health Services
DNPL -Delisted National Priority List
DOB -Department of Buildings
DOH -Department of Health
DOT -Department of Transportation
EPA -Environmental Protection Agency
ERNS -Emergency Response Notification System
FD -Fire Department
FOI/FOIA/FOIL -Freedom of Information / Freedom of Information Act / Freedom of Information Letter HVAC -Heating Ventilation & Air Conditioning
HREC -Historical Recognized Environmental Condition
IAQ -Indoor Air Quality
ISRA -Industrial Site Recovery Act
LBP -Lead-Based Paint
LCP -Lead-Containing Paint
LQG -Large Quantity Generator
LTANK -Leaking Storage Tank
LUST -Leaking Underground Storage Tank
SDS/MSDS -Safety Data Sheet / Material Safety Data Sheet NA -Not Applicable
NFA -No Further Action
NFRAP -No Further Remedial Actions Planned
NPDES -National Pollutant Discharge Elimination System
NPL -National Priorities List
OPRA -Open Public Records Act
PAH -Polycyclic Aromatic Hydrocarbon
PCE -Perchloroethylene
RAO -Response Action Outcome
RCRA -Resource Conservation and Recovery Act
RCRIS -Resource Conservation and Recovery Information System REC -Recognized Environmental Concern
SDG -Significant Data Gap
SEMS -Superfund Enterprise Management System
SRP -Site Remediation Program
SQG -Small Quantity Generator
SVOC -Semi-Volatile Organic Compound
TCE -Trichloroethylene
TSDF -Treatment Storage and/or Disposal Facility
UST -Underground Storage Tank
VEC -Vapor Encroachment Condition
VOC -Volatile Organic Compound
Phase I Environmental Site Assessment -ii- C3-10154
1.0 INTRODUCTION
1.1 Executive Summary
Hillmann Consulting LLC (Hillmann) has performed a Phase I Environmental Site Assessment (ESA) of 100 - 190 South Sixth Avenue, 14404 -14436 East Valley Boulevard, City of Industry, California (the Subject Property) in accordance with our contracted scope of work and the ASTM Standard Practice E 1527-21 for Phase I Environmental Site Assessments and All Appropriate Inquiries (AAI) Final Rule 40 CFR Part 312. This section contains a summary of findings, opinions and conclusions made by this assessment. However, this section, alone, does not constitute the complete assessment. The report must be read in its entirety.
Summary of Project Details
Primary Street Address: 100 - 190 South Sixth Avenue, 14404 -14436 East Valley Boulevard City: City of Industry County: Los Angeles State: California Tax ID/Parcel Number: 8206027058, 8206027080
Property Owner: Richard C. Hunsaker
Zoning Designation: Light Manufacturing
Approx. Property Area: 6.47 acres
Buildings: Six
Approx. Building Size: 28,800 SF (Building A), 17,280 SF( Building B), 19,200 SF ( Building C), 12,800 SF (Fmr. Building D), 8,640 SF (Building E), 8,640 SF (Building F), 12,800 SF (Building G)
Approx. Year Built: 1977
Commercial Occupants: See rent roll
Current Use: Commercial/ lLight Industrial
Site Visit Personnel: Kofi Bonner
Site Contact/Company: Kelvin Koh / CapRock Partners
Site Escort/Company: Unescorted /
Inspection Date: September 11, 2024
Weather Conditions: 87° F / Sunny
Phase I Environmental Site Assessment -1- C3-10154
Findings Summary Table
Assessment Subject No REC REC CREC HREC SDG Rpt. Ref.
Regulatory Records Review: 4.1
Historical Records Review: 4.2
Bulk Petroleum Storage: 6.3
On-Site Operations: 6.3
On-Site Haz-Mat Storage/Use/Spills: 6.3
Transformers/Hydraulic Systems: 6.3
Waste Discharges: 6.3
Interviews: 5.0
Adjoining/Surrounding Area: 4.0 6.2
Prior Env. Reports/User Provided Info: 3.0
1.2 Findings, Opinions and Conclusions
Recognized Environmental Conditions & Significant Data Gaps Hillmann has performed a Phase I Environmental Site Assessment in accordance with the scope and limitations of ASTM Practice E 1527-21 of the Subject Property as described in Section 2.2 of this report. Any additions to, exceptions to, or deletions from this practice are also described in Section 2 of this report. This assessment has revealed the following recognized environmental conditions (RECs), controlled recognized environmental conditions (CRECs) and/or significant data gaps (SDGs) in connection with the Subject Property:
RECOGNIZED ENVIRONMENTAL CONDITIONS
No RECs were identified.
CONTROLLED RECOGNIZED ENVIRONMENTAL CONDITIONS
The Subject Property is located within a broad area of groundwater contamination that is part of the “Puente Valley/San Gabriel Valley Area 4” Superfund site.
According to the USEPA, Puente Valley is one of eight (8) operable units (OUs) of the San Gabriel Valley Superfund case and is also known as San Gabriel Valley Superfund Site Area 4. The Puente Valley OU includes most of the City of Industry, portions of the City of La Puente, and portions of unincorporated Los Angeles County. Groundwater and soil are contaminated with various volatile organic compounds (VOCs, primarily trichloroethene (TCE) and tetrachloroethene (PCE)), 1,4-dioxane, perchlorate, and hexavalent chromium. Groundwater contamination occurs primarily in the shallow and intermediate groundwater zones of the aquifer, with most of the contaminant mass found in the shallow groundwater zone. VOC concentrations exceed drinking water standards in both the shallow and intermediate zones.
Based on a review of groundwater quality data indicated by a 2017 monitoring report for Puente Valley Operable Unit-Shallow Zone North Remedy, monitoring wells installed within the shallow groundwater zone on adjoining properties to the southeast and northwest (MW-13 and MW-14) indicated zero to minimal concentrations of VOCs below MCLs, and depths to groundwater of approximately 50 to >60 feet below grade.
The EPA is identified as the regulatory agency and there are remedial actions underway. Hillmann found no indication of current/former occupants of the Subject Property having been identified as contributing to the contaminant plume. Based on review of WIP database listings, former Phase I Environmental Site Assessment -2- C3-10154
tenants of the Property were investigated in the 1980s for potentially contributing and granted "Case-Closed" status in 1987. Two (2) adjoining historical facilities appear to have been flagged as potentially contributing; however, neither were identified by regulatory review as having unresolved contamination cases. Considering that the NPL/Superfund case is actively managed by the USEPA, the regional groundwater plume is considered to be a CREC in connection with the Subject Property.
SIGNIFICANT DATA GAPS
No SDGs were identified.
RECOMMENDATIONS
No additional investigation is recommended regarding the Puente Valley/San Gabriel Valley Area 4 NPL case. Use of groundwater beneath the Subject Property is likely restricted and subject to agency notifications/approval. It is Hillmann's opinion that no additional action or investigation is warranted at this time.
Historical Recognized Environmental Conditions (HRECs)
If identified, historical recognized environmental conditions (HRECs) in connection with the Subject Property are described below:
HISTORICAL RECOGNIZED ENVIRONMENTAL CONDITIONS
No HRECs were identified.
De Minimis and Other Environmental Conditions
If identified, de minimis and other environmental conditions are described below:
OTHER ENVIRONMENTAL CONDITIONS / DE MINIMIS CONDITIONS
1. The Subject Property has been utilized by multiple tenants for various light industrial operations since approximately 1977. Historical occupants included several printing/graphics businesses, which are considered potentially high risk for environmental impacts. Other occupants included light manufacturing operations, machine servicing businesses, auto painting supplies, and oil supplies. Phase I ESA reports by Hillmann in 2023 concluded that, collectively, the historical light industrial operations since 1977 were considered to a REC in connection with the Subject Property due to the potential for undocumented spills/releases of hazardous substances and/or petroleum hydrocarbons to have occurred.
Hillmann performed a Limited Phase II Subsurface Investigation in May 2023 to address concerns of potential contamination on the Subject Property from historical uses and nearby offsite sources. Hillmann proposed a Limited Phase II Subsurface assessment that included twenty-one (21) soil borings and twenty (20) soil gas probes on the Subject Property. The report indicated the following conclusions:
"The results from soil sampling indicated no detectable concentrations of petroleum hydrocarbons and no heavy metals concentrations greater than current residential or commercial screening levels. The results from PFAS testing beneath the burned former building indicate many of these compounds were detected, but none at significant concentrations. The results from soil gas sampling indicate very low concentrations of VOC in some samples, none greater than current commercial screening levels."
"Based on these results, no additional sampling is recommended for the site." Based on the findings of the 2023 limited subsurface investigation, the historical uses of the Subject Property are
Phase I Environmental Site Assessment -3- C3-10154
not considered to be a REC in association with the Subject Property.
2. A former occupant of the Subject Property, Duraware Plastics, was listed on the CERS. CPS-SLIC and CHMIRS databases. The CERS listing indicated the facility on the Subject Property was registered as a Cleanup Program Site with a Site ID of “602373” and a CERS ID of “T10000014239.” The CPS-SLIC listing indicated the former occupant Duraware Plastics Co. was investigated in the 1980s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination. There was no indication of an actual reported release. The case was granted "Completed - Case Closed" status on August 11, 1987. The CHMIRS listing indicated the site had a release on March 18, 2021. According to the listing, the release was of diesel exhaust fluid to the road, as a result of a multi-vehicle collision. The listing reported a release of 10 gallons that was cleaned up by the tow company onsite, and that no waterways or storm drains were affected. Based on the details provided above, a REC is not suspected in connection with the Subject Property.
3. A former occupant of the Subject Property, Victory Coating, Inc., was listed on the CERS and CPS-SLIC databases. The CERS listing referenced "Well Investigation Program-Los Angeles RWQCB" and indicated the facility on the Subject Property was registered as a Cleanup Program Site with a Site ID of “605255” and a CERS ID of “T10000014262.” The related CPS-SLIC listing indicated the former occupant Victory Coating was investigated in the mid-1980s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination. There was no indication of an actual reported release. The case was granted "Completed - Case Closed" status on February 5, 1987. Based on the details provided above, these listings are not considered to be REC in connection with the Property.
4. A former occupant of the Subject Property, Elite Salon Service, -14420 Valley Boulevard, was listed on the CERS, CPS-SLIC and WIP databases. The WIP, CERS and CPS-SLIC listings indicated the site was investigated in the mid-1980s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination. The case was granted "Completed - Case Closed" status on December 16, 1996. Based on the details provided above, a REC is not suspected in connection with the Subject Property.
5. An adjoining property to the west, Former Patterson Resources-161 Sixth Avenue, was listed on the CPS-SLIC, WIP and CERS databases. This site is located approximately 65 feet cross gradient of the Subject Property. The WIP, CERS and CPS-SLIC listings indicated the site was investigated in the mid-1980s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination. A release was reported in 1985 and was granted "Completed - Case Closed" status on October 23, 2009. According to the online Geotracker Database, several soil and groundwater investigations were conducted in 1989 to characterize the historical activities of heavy equipment use, repair, and storage, as well as welding and component building at the Subject facility. The RWQCB granted the site "Case Closure" on October 23, 2009.
Based on the regulatory oversight, and positioning of the site in reference to the Subject Property these listings are not considered a REC in association with the Subject Property.
6. An adjoining property to the southeast, 14505 Proctor Avenue cross/downgradient of the Subject Property, was listed on the CPS-SLIC, AST, RCRA-SQG, DEED, WIP and other databases.
The listings were under the names Former Packaging Corporation, Hilltop Mini Mart, and Pactiv Corporation. Available details from the Radius Map report and online Geotracker portal indicated that a release was reported in 1990 and granted "Completed - Case Closed" status on August 21, 2012. The facility formerly managed an AST farm area that held petroleum and non-chlorinated volatile organic compounds tanks. Investigations from 1986 to 1989 identified styrene, ethylbenzene, and oil as the main impacts in the subsurface, in addition to several detected VOCs.
From 1996 to 2010 Vapor extraction has been used to mitigate concentrations of ethylbenzene and styrene in soil. As a result of residual contamination, the property was given a "Land Use Covenant" on March 16, 2012. The RWQCB granted the site "Case Closure" on August 21, 2012.
Phase I Environmental Site Assessment -4- C3-10154
Based on the available database details as well as the 2023 limited subsurface investigation findings, the site and historical use is not considered to be a REC in connection with the Subject Property.
Environmental Professional Statement
I/We declare that, to the best of my professional knowledge and belief, I/we meet the definition of Environmental professional as defined in § 312.10 of 40 C.F.R. 312. I/we have the specific qualifications based on education, training and experience to assess a property of the nature, history and setting of the subject property. I/We have developed and performed all appropriate inquiries in conformance with the standards and practices set forth in 40 C.F.R. Part 312.
Ryan Terwilliger
Environmental Professional
David Rutherford
Environmental Professional
Phase I Environmental Site Assessment -5- C3-10154
1.3 Business Environmental Risks / Non-ASTM Scope
Hillmann has performed a limited review of the following potential business environmental risks (BER), also known as “Non-ASTM Scope” concerns, in accordance with the contracted scope of work scope for this assessment. Additional details of the scope of work and findings are included in Sections 2 and 7.
Subject Findings
Not
Appl.
Rpt.
Ref.
Asbestos Suspected ACM noted within the accessed building areas included vinyl sheet flooring, floor tiles and associated mastic, mirror mastic, carpeting and associated mastic, roofing systems, penetration mastics, and thermal systems insulation.
7.1 Lead Paint No residential buildings built prior to 1978 were present at the Property. 7.2 Radon Property is located in the USEPA radon designation Zone 2 or 'moderate risk' area for radon.
7.3 Mold/
Microbial
Damage
No evidence of significant problems with moisture intrusion or mold/ microbial growth was noted at the Subject Property.
7.4 NWI
Wetlands
A review of NWI Wetlands Mapper did not indicate regulated wetland areas on the Property.
7.5 Lead
in Drinking
Water
Potable water service at the Property is provided by a utility connection with San Gabriel Valley Water Company. A recently published water quality report from the utility indicated compliance with USEPA water quality standards for lead in drinking water.
7.6 Phase I Environmental Site Assessment -6- C3-10154
2.0 GENERAL
2.1 Purpose and Scope
This assessment was conducted utilizing generally accepted Phase I ESA industry standards in accordance with the ASTM Standard Practice E 1527-21. The ASTM describes these methodologies as representing good commercial and customary practice for conducting an environmental site assessment of a parcel of commercial real estate with respect to the range of contaminants within the scope of the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) (42 U.S.C. § 9601) and petroleum products. This practice is intended to permit a user to satisfy one of the requirements to qualify for the innocent landowner, contiguous property owner or bona fide prospective purchaser limitations on CERCLA liability (“landowner liability protections,” or “LLPs”): that is, the practice that constitutes all appropriate inquiries into the previous ownership and uses of the Subject Property consistent with good commercial and customary practice as defined at 42 U.S.C. §9601(35) (B). The goal of the processes established by ASTM E1527-21 is to identify recognized environmental conditions in connection with the Subject Property.
The term recognized environmental condition (REC) is defined by ASTM E1527-21 as “(1) the presence of hazardous substances or petroleum products in, on, or at the subject property due to a release to the environment; (2) the likely presence of hazardous substances or petroleum products in, on, or at the subject property due to a release or likely release to the environment; or (3) the presence of hazardous substances or petroleum products in, on, or at the subject property under conditions that pose a material threat of a future release to the environment.” The term controlled recognized environmental condition (CREC) is a type of recognized environmental condition and defined by ASTM E1527-21 as a “recognized environmental condition affecting the subject property that has been addressed to the satisfaction of the applicable regulatory authority or authorities with hazardous substances or petroleum products allowed to remain in place subject to implementation of required controls (for example, activity and use limitations or other property use limitations).”
The term historical recognized environmental condition (HREC) is defined as a “previous release of hazardous substances or petroleum products affecting the subject property that has been addressed to the satisfaction of the applicable regulatory authority or authorities and meeting unrestricted use criteria established by the applicable regulatory authority or authorities without subjecting the subject property to any controls (for example, activity and use limitations or other property use limitations).” The ASTM E1527-21 standard has clarified that a historical recognized environmental condition is not a recognized environmental condition.
The term de minimis condition is defined by the ASTM, “…a condition related to a release that generally does not present a threat to human health or the environment and that generally would not be the subject of an enforcement action if brought to the attention of appropriate governmental agencies.” A condition determined to be a de minimis condition is not REC nor a CREC.
The chief components of this assessment are generally described as follows:
▪ A non-invasive visual reconnaissance of the Subject Property and adjoining properties in accordance with ASTM guidelines for evidence of RECs.
Phase I Environmental Site Assessment -7- C3-10154
▪ Interviews of past and present owners and occupants and state and local government officials, seeking information related to the potential presence of RECs at the Subject Property.
▪ A review of standard physical record sources for available topographic, geologic and groundwater data.
▪ A review of standard historical record sources, such as fire insurance maps, city directories, aerial photographs, prior reports and interviews, etc., to determine prior uses of the Subject Property from the present, back to the Subject Property’s first developed use, or back to 1940, whichever is earlier.
▪ A review of standard environmental record sources including federal and state environmental databases, and additional environmental record sources, to identify potential regulatory concerns with the Subject Property, adjoining properties and properties located within the surrounding area.
An evaluation of environmental or other regulatory compliance matters is excluded from the scope of this assessment.
These methodologies are described as representing good commercial and customary practice for conducting an Environmental Site Assessment of a property for the purpose of identifying recognized environmental conditions.
Business Environmental Risks/Non-ASTM Scope Considerations Hillmann has performed a limited review of the following potential business environmental risks (BER), also known as “Non-ASTM Scope” concerns, in accordance with the contracted scope of work scope for this assessment. BER is defined by ASTM E 1527-21 as “a risk which can have a material environmental or environmentally-driven impact on the business associated with the current or planned use of a parcel of commercial real estate, not necessarily limited to those environmental issues required to be investigated in this practice.”
▪ Asbestos-Containing Materials (ACM): A cursory non-intrusive visual screening for the presence of suspect ACM within the accessed areas of buildings built prior to 1990 on the Subject Property. If the Subject Property contains buildings built in 1990 or later, the contracted scope of work excludes a cursory non-intrusive visual screening or any other level of evaluation for suspect ACM; however, the exclusion for buildings built ≥1990 should not be interpreted to suggest that any such buildings are free of ACM or would not warrant evaluation of building materials for ACM prior to disturbance. It is emphasized that this cursory non-intrusive visual screening does not constitute an asbestos survey/inspection of the premises. An asbestos survey/inspection should be sought by the report User(s) if a greater certainty is desired regarding ACM and potential asbestos hazards at the Subject Property. Furthermore, a review of regulatory compliance matters pertaining to asbestos is excluded from the scope of work.
▪ Lead-Based Paint (LBP): A cursory non-intrusive visual screening of the condition of painted surfaces in the accessed areas of residential buildings/units built prior to 1980 on the Subject Property. If the Subject Property contains buildings built in 1980 or later, the contracted scope of work excludes any cursory non-intrusive visual screening or other level of evaluation for suspect LPB; however, the scope of work exclusion for building built ≥1980 should not Phase I Environmental Site Assessment -8- C3-10154
be interpreted to suggest that any such buildings are free of LPB or other lead hazards.
It is emphasized that this cursory non-intrusive visual screening does not constitute a comprehensive survey for LBP or potential lead hazards. A comprehensive inspection should be sought by the report User(s) if more certainty is desired regarding LBP at the Subject Property. Furthermore, a review of regulatory compliance matters pertaining to lead-based paint is excluded from the scope of work.
▪ USEPA Designated Radon Potential: Review of general non-site specific data published by the USEPA regarding the Radon Zone classification for the area of the Subject Property. ▪ Mold/Microbial Damage: A cursory non-intrusive visual screening within the accessed areas of buildings on the Subject Property for evidence of systemic microbial problems, including visible mold growth, water damaged building materials or musty odors. It is emphasized that this cursory non-intrusive visual screening does not constitute a comprehensive survey for moisture/mold/microbial damage. A more comprehensive inspection should be sought by the report User(s) if more certainty is desired regarding the potential for moisture/mold/microbial damages at the Subject Property.
▪ NWI Wetlands: The Subject Property has been reviewed for jurisdictional wetlands using the National Wetlands Inventory-Wetland Mapper to determine whether mapped federal wetlands have been indicated on the Subject Property. Any further evaluation or legal delineation of regulated wetlands areas is excluded from the scope of work. It is also emphasized that a field delineation of regulated wetlands by a qualified professional would be warranted to more fully determine the presence or absence of regulated wetlands at the Subject Property.
▪ Lead in Drinking Water: Review of the potential for elevated levels of lead in the drinking water by determining the source of the drinking water supply and a review of available testing or compliance data reports.
2.2 Property Location/Legal Description
Property location and legal description details are described as follows:
Primary Street Address: 100 - 190 South Sixth Avenue, 14404 -14436 East Valley Boulevard
City: City of Industry County: Los Angeles State: California Tax ID/Parcel Number: 8206027058, 8206027080
Approx. Land Area: 6.47 acres
Apprx. Latitude/Longitude: North 34.0360820 degrees/West 117.9783610 degrees Additional Details (if appl.) N/A
Property Owner: Richard C. Hunsaker
Zoning Designation: Light Manufacturing
Phase I Environmental Site Assessment -9- C3-10154
2.3 Data Gaps
A data gap is defined by the ASTM as a lack of or inability to obtain information required by this practice despite good faith efforts by the environmental professional to gather such information. A data gap is only significant if other information and/or professional experience raises reasonable concerns involving the data gap and the ability to determine the presence or absence of recognized environmental conditions. The following table summarizes data gaps encountered during the assessment as well as a discussion of their significance.
Data Gap:
Significant
(Yes/No)? Discussion
Historical records data failure No The date and/or type of the first developed use of the Subject Property was not determined.
Records gaps exceeding five years were encountered;
however, no significant site use changes are suspected
during these intervals.
Response to agency records
requests not received as of date
of report.
No Any additional information indicative of a REC will be forwarded upon receipt.
User and Owner
questionnaires were not
received as of date of report
No Any additional information indicative of a REC will be forwarded upon receipt.
2.4 ESA Report Component Dates/Viability
The ASTM E1527-21 standard states that an environmental site assessment (ESA) is presumed to be viable when it is conducted within 180 days prior to the date of acquisition of the Subject Property (or, for transactions not involving an acquisition such as a lease or refinance, the date of the intended transaction). Specifically, all of the following components must be conducted or updated within 180 days prior to the date of acquisition or prior to the date of the transaction.
The following table summarizes the component completion dates:
ESA Component Completion Date
Interviews: Last attempt: September 10, 2024
Env. Lien Search: (excluded from scope)
Government Records Review: September 3, 2024
Visual Inspections: September 11, 2024
Env. Professional Declaration: September 18, 2024
2.5 User Reliance
This report is for the exclusive use of CapRock Partners and additional relying entities, if any, named on the front cover. No additional individuals or entities shall be permitted to rely upon any data, interpretation, reports or other information or documentation contained in this report, without first obtaining the consent of CapRock Partners; and without obtaining written consent from Hillmann in the form of a reliance agreement/letter.
Phase I Environmental Site Assessment -10- C3-10154
Hillmann may, in its sole discretion, withhold its consent to additional reliance and/or Hillmann may condition consent for reliance upon payment of a fee or other conditions.
2.6 Significant Assumptions
The following significant assumptions are made:
▪ The site operations at the time of the site visit are assumed to reflect typical site conditions relative to potential environmental conditions and that no concealment of environmental conditions or releases by site owners or occupants has occurred. Likewise, it is assumed that no areas of the Subject Property with potential environmental concerns or RECs were concealed or otherwise not reported, intentionally or unknowingly, by the Subject Property owners/occupants and/or site escort at the time of the site visit. ▪ For the purpose of estimating the approximate direction of groundwater flow in the absence of site-specific groundwater data, unless indicated otherwise, an assumption has been made that the gradient of groundwater flow follows the surface topography of the Subject Property and immediate surrounding area.
2.7 General Limitations and Exceptions
Limitations
The report turnaround time specified by the contract agreement for this assessment may present a limitation to the availability of pertinent regulatory agency records. Such limitations, if encountered, would be further specified in Section 4.1.
Significant limitations related to the condition or accessibility of the Subject Property at the time of the site reconnaissance, if encountered, are reported in Section 6.1.
Other Exceptions or Deletions
No other exceptions or deletions from the ASTM Standard E 1527-21 are reported.
Special Terms and Conditions
This Phase I Environmental Site Assessment has been prepared using reasonable efforts in each phase of its work to identify recognized environmental conditions associated with hazardous substances, wastes and petroleum products at the Subject Property. Findings within this report are based on information collected from observations made on the day of the site reconnaissance and from reasonably ascertainable information obtained from governing public agencies and private sources.
This report is not definitive and should not be assumed to be a complete or specific definition of the conditions above or below grade. Information in this report is not intended to be used as a construction document and should not be used for demolition, renovation, site development, redevelopment, or other construction purposes. No representation or warranty is made that the past or current operations at the Subject Property are, or have been, in compliance with all applicable federal, state and local laws, regulations and codes.
Phase I Environmental Site Assessment -11- C3-10154
Findings, conclusions and recommendations presented in this report are based on visual observations of the Subject Property, interviews conducted, the records reviewed, information provided by the Client, and/or a review of readily available and supplied drawings and documents.
No warranty or guarantee is made of the accuracy or completeness of information that was obtained from ostensibly knowledgeable individuals, regulatory agency representatives or other secondary sources, including information obtained during the assessment, whether written, graphic or verbal, provided by the Subject Property contact(s) or as shown on any documents reviewed or received from the Subject Property contact, owner or agent, or government agency source. Independent verification of the accuracy or completeness of all information reviewed or received during the course of this assessment is not made and excluded from the scope of work for this assessment.
Regardless of the findings stated in this report, Hillmann is not responsible for consequences or conditions arising from facts that were concealed, withheld or not fully disclosed at the time the assessment was conducted.
This report does not warrant against future operations or conditions, nor does it warrant against operations or conditions present of a type or at a location not investigated.
The regulatory database report provided is based on an evaluation of the data collected and compiled by a contracted data research company. Hillmann can neither warrant nor guarantee the accuracy or completeness of the information obtained from the regulatory database report provider during the course of this assessment.
Subsurface conditions may differ from the conditions implied by the surface observations and can only be reliably evaluated through intrusive techniques.
Reasonable efforts have been made during this assessment to identify aboveground and underground storage tanks and ancillary equipment. Reasonable efforts are limited to information gained from visual observation of largely unobstructed areas, recorded database information held in public record and available information gathered from interviews. Such methods may not identify surficial and subsurface features that may have been hidden from view due to parked automobiles and other vehicles, snow cover, vegetative growth, pavement, construction or debris pile storage or incorrect information from sources.
No guarantee, explicit or implied, is made that the records pertaining to historical ownership or occupancy which were reviewed represent a comprehensive or precise delineation of past Property ownership or tenancy for legal purposes.
The ASTM E1527-21 standard states that recommendations are not required to be included in a Phase I ESA report; however, further that recommendations are an additional service that may be useful in the User’s analysis of landowner liability protections or business environmental risks; and that the User should consider whether recommendations for additional inquiries or other services are desired.
Recommended response actions offered in Section 1.3, if any, are provided as an option to the Client, and may have taken into account the Client’s relation to the Subject Property and/or their intended purpose of this assessment. If included, it is not intended by Hillmann to represent the only course(s) of action, or inaction, to take. Furthermore, it is emphasized that additional response actions may become advisable depending on the outcome of the initial action(s) Phase I Environmental Site Assessment -12- C3-10154
taken. Hillmann advises that Client and any additional authorized relying parties as specified on the report Cover and Section 2.5, or via letter of reliance extension, undertake consultation with legal counsel familiar with environmental and real estate law would be beneficial to the decision making process for the type and timing of a response action to identified RECs or Business Environmental Risks, if any.
Due to the limited nature of our review of potential Business Environmental Risks, the User(s) of the report should consider whether to take additional action(s) to further define, properly manage and/or mitigate potential BERs.
The User(s) assumes responsibility for business decisions that it makes utilizing information in the report provided by Hillmann. Hillmann shall not be responsible for any conclusions, interpretations and/or decisions of the User(s).
In the event of any conflict between the terms and conditions of this report and the terms and conditions of the consulting services agreement for this project, the consulting services agreement shall control.
Phase I Environmental Site Assessment -13- C3-10154
3.0 USER PROVIDED INFORMATION
The term “User” is defined by ASTM as the party seeking to use Practice E1527 to complete an environmental site assessment of the Subject Property; specifically, the entity or entities named on the front cover to which the report has been addressed.
3.1 Prior Environmental Reports/Documentation
Environmental Property Investigation, Don Julian and Valley Center Properties 15151 Don Julian Road, 525 - 427 Turnbull Canyon Road, 100 - 190 South Sixth Street & 14404-14436 Valley Boulevard, City of Industry, CA; prepared by Hydrotech Consultants, Inc.; dated September 27, 1989. The report concluded the following:
“This investigation has yielded evidence that hazardous substances may have impacted both Subject sites...
7.2 Valley Center Boulevard
Soil and groundwater contamination in the San Gabriel groundwater basin is presently under investigation by the RWQCB, State DHS and USEPA. Several potentially responsible parties for portions of this contamination have been identified in the vicinity of the Subject site.
Information acquired by the RWQCB from A & E Plastics, a neighboring site upgradient from the Subject site, suggests that soil and groundwater contaminants may have migrated on to the Subject site. The RWQCB may request in the near future that access be given to A & E Plastics to the Subject site to conduct additional investigations (Phil Chandler, RWQCB, pers. comm., 1989).
Additionally, observations made at the Subject site suggest that organic contaminants have been spilled adjacent to the Subject site near the railroad property boundary with A & E Plastics.
Therefore, Hydrotech concludes that contaminants related to site use activities may be present within on-site soils or groundwater. Asbestos was not identified in building materials that were sampled in the 100 South Sixth Street unit. To the extent that identical building materials were used during construction in all other areas of the Valley Center Property, asbestos was not identified in the materials sampled and no further work is recommended... - Hydrotech recommends further communication with the RWQCB to investigate details of studies in progress at adjacent sites and establish what investigative actions may be required for the A & E Plastics study.
- Finally, Hydrotech recommends that the responsible party for the organic liquid spill adjacent to Magnum be identified. Once identified, the responsible party should be required to characterize and remediate any associated soil and groundwater contamination. This area is likely to be noticed during any future RWQCB work regarding A & E Plastics and may bring the subject site under regulatory pressures." Phase I Environmental Site Assessment, 100-190 South Sixth Avenue, City of Industry, CA; prepared by Hillmann Consulting, LLC; dated April 27, 2023. This scope of this report only included parcel 8206027058 and excluded parcel 8206027080. The report concluded the following:
Phase I Environmental Site Assessment -14- C3-10154
"The adjoining property to the east addressed as 14505 Proctor Avenue located approximately 700 feet to the southeast and cross/downgradient of the Subject Property had a release and was granted "Completed - Case" Closed status on August 21, 2012. The CPS-SLIC listing indicated the site known as the Former Packaging Corporation or Pactiv Corporation facility.
The facility formerly managed an AST farm area that held petroleum and non-chlorinated volatile organic compounds tanks. Investigations from 1986 to 1989 identified styrene, ethylbenzene, and oil as the main impacts in the subsurface, in addition to several detected VOCs. From 1996 to 2010 Vapor extraction has been used to mitigate concentrations of ethylbenzene and styrene in soil. As a result of residual contamination, the property was given a Land Use Covenant on March 16, 2012. The RWQCB granted the site case closure on August 21, 2012. However, based on the positioning of the site in reference to the Subject Property and the nature of the remedial methods utilized, these listings are considered a REC in connection with the Subject Property. A REC is considered due to the potential for soil vapor intrusion at the area immediately adjoining the adjoining tank farm. The Subject Property has been utilized by multiple tenants for various light industrial operations since approximately 1977. Historical occupants included several printing/graphics businesses, which are considered potentially high risk for environmental impacts. Other occupants included light manufacturing operations, machine servicing businesses, auto painting supplies, and oil supplies. Collectively, the historical light industrial operations since 1977 are considered a REC in connection with the Subject Property due to the potential for undocumented spills/releases of hazardous substances and/or petroleum hydrocarbons to have occurred." Additionally, the report identified the following CREC in association with the Subject Property:
" A portion of the Property was listed as “San Gabriel Valley Area (2 & 4)” on the Los Angeles County Areas of Concern (AOC) database due to previously reported VOCs in groundwater exceeding Maximum Contaminant Levels (MCLs) as designated by region 9 EPA. The EPA is identified as the regulatory agency and there are remedial actions underway."
Hillmann recommended the following:
"A Phase II Investigation is recommended to further evaluate the potential for subsurface impacts due to historical industrial uses as well as the adjoining former Packaging Corp site to the southeast."
Phase I Environmental Site Assessment, 14404 -14436 East Valley Boulevard, La Puente, CA; prepared by Hillmann Consulting, LLC; dated April 27, 2023. This scope of this report only included parcel 8206027080 and excluded parcel 8206027058. The report concluded the following:
"The Subject Property has been utilized by multiple tenants for various light industrial operations since approximately 1977. Historical occupants included several printing/graphics businesses, which are considered potentially high risk for environmental impacts. Other occupants included light manufacturing operations, machine servicing businesses, auto painting supplies, and oil supplies. Collectively, the historical light industrial operations since Phase I Environmental Site Assessment -15- C3-10154
1977 are considered a REC in connection with the Subject Property due to the potential for undocumented spills/releases of hazardous substances and/or petroleum hydrocarbons to have occurred."
Additionally, the report identified the following CREC in association with the Subject Property:
" A portion of the Property was listed as “San Gabriel Valley Area (2 & 4)” on the Los Angeles County
Areas of Concern (AOC) database due to previously reported VOCs in groundwater exceeding
Maximum Contaminant Levels (MCLs) as designated by region 9 EPA. The EPA is identified as the
regulatory agency and there are remedial actions underway. The San Gabriel Valley Areas 2 and 4
represent a CREC in association with the Subject Property." Hillmann recommended the following:
"A Phase II Investigation is recommended to further evaluate the potential for subsurface impacts due to historical industrial uses."
Limited Phase II Subsurface Investigation Report, 100-190 S. SIXTH AVE. AND 14404-14436 E.
VALLEY BLVD., CITY OF INDUSTRY/ LA PUENTE, CA; Prepared by Hillmann Consulting, LLC; dated June 1, 2023. The scope of work is summarized as follows:
In April 2023, Hillmann conducted a Phase I Environmental Site Assessment at the site and found that the property has been utilized by multiple tenants for various light industrial operations since approximately 1977. Historical occupants included several printing/graphics businesses, which are considered potentially high risk for environmental impacts. Other occupants included light manufacturing operations, machine servicing businesses, warehouse storage, auto painting supplies, and oil supplies. Based on the historical use of the Subject Property Hillmann proposed a Limited Phase II Subsurface assessment that involved installing twenty-one (21) soil borings and installing a total of twenty 20) soil gas probes on the Subject Property. Specifically...
" a total of twenty (20) soil gas probes in targeted areas of the site identified as formerly or currently maintaining suspect operations, including printing and other light industrial use. These included tenant suites located at 14414, 14420, and 14426 East Valley Boulevard and 110, 122, 126, 132, 138, and 190 South Sixth Avenue. Two (2) of the borings (B19 and B20) were installed at the edge of the footprint of the burned former structure at 140-148 South Sixth Avenue. The borings were installed to total depths ranging from 2.5 to 6 feet below grade using hand auger tools. Each boring (except for B19) was completed as a soil gas sampling probe (SG1-SG21) with sample tips installed at maximum depth. A twentieth soil gas probe (SG21) was installed near the southeast corner of the site nearest to the off-site impacted property that was closed with restrictions." Hillmann reported the following conclusions regarding the Subject Property:
Phase I Environmental Site Assessment -16- C3-10154
"The results from soil sampling indicated no detectable concentrations of petroleum hydrocarbons and no heavy metals concentrations greater than current residential or commercial screening levels.
The results from PFAS testing beneath the
burned former building indicate many of these compounds were detected, but none at significant concentrations. The results from soil gas sampling indicate very low concentrations of VOC in some samples, none greater than current commercial screening levels.
Based on these results, no additional sampling is recommended for the site."
3.2 User Responsibilities
A User Questionnaire was provided to the User to assist in gathering information, as detailed below, that is required for disclosure during the assessment to meet All Appropriate Inquiry requirements. If completed and returned to Hillmann, a copy of the Questionnaire has been included in Appendix C.A completed questionnaire was not returned to Hillmann.
Question: Yes/No: Detail:
1. Search of Land Title and Judicial Records: Has the User performed a search of land title records and judicial records for environmental liens and/or Activity and Use Limitations (AULs) filed or recorded against the Subject Property? NA
1.a. If yes to Question 1: Did the search identify any environmental liens or Activity and Use Limitations (AUL), such as engineering controls, land use restrictions or institutional controls that are in place at the Subject Property and/or have been filed or recorded against the Subject Property under federal, tribal, state or local law?
NA
1.b. If yes to Question 1: Has the User provided the result of the search of land title and judicial records to Hillmann?
NA
2. Specialized knowledge or experience of the person seeking to qualify for the LLP: Do you have any specialized knowledge or experience related to the Subject Property or nearby properties? For example, are you involved in the same line of business as the current or former occupants of the Subject Property or an adjoining property so that you would have specialized knowledge of the chemicals and processes used by this type of business?
NA
3. Relationship of the purchase price to the fair market value of the Subject Property if it were not contaminated: Does the purchase price being paid for this property reasonably reflect the fair market value of the Subject Property? If you conclude that there is a difference, have you considered whether the lower purchase price is because contamination is known or believed to be present at the Subject Property?
NA
4. Commonly Known or Reasonably Ascertainable Information: Are you aware of commonly known or reasonably ascertainable information about the Subject Property that would help the environmental professional to identify conditions indicative of releases or threatened releases? For example:
NA
4.a. Do you know the past uses of the Subject Property? NA
4.b. Do you know of specific chemicals that are present or were once present at the Subject Property?
NA
Phase I Environmental Site Assessment -17- C3-10154
4.c. Do you know of spills or other chemical releases that have taken place at the Subject Property?
NA
4.d. Do you know of any environmental cleanups that have taken place at the Subject Property?
NA
5. The degree of obviousness of the presence or likely presence of contamination at the Subject Property, and the ability to detect the contamination by appropriate investigation: Based on your knowledge and experience related to the Subject Property are there any obvious indicators that point to the presence or likely presence of releases at the Subject Property? NA
6. Litigation, Administrative Proceedings, Government Notices: As the User of this ESA, do you have knowledge of (1) any pending, threatened, or past litigation relevant to hazardous substances or petroleum products in, on, or from the Subject Property; (2) any pending, threatened, or past administrative proceedings relevant to hazardous substances or petroleum products in, on or from the Subject Property; and (3) any notices from any governmental entity regarding any possible violation of environmental laws or possible liability relating to hazardous substances or petroleum products.
NA
7. User’s Reason/Purpose for Performing Phase I ESA: Hillmann understands that the assessment is being prepared in
connection with a prospective real
estate transaction involving the
Property.
Phase I Environmental Site Assessment -18- C3-10154
4.0 RECORDS REVIEW
4.1 Environmental Information
Physical Setting
Source Discussion
USGS 7.5 minute
Topo Map:
The Subject Property lies at an elevation of approximately 299 feet above mean sea level. An interpretation of topographic contour lines as well as a review of the EDR Geocheck-General Topographic Gradient suggested terrain sloping downward towards the southwest.
USDA Soil Data:
(EDR GeoCheck)
The soil type at the Subject Property is classified as "Urban Land". The Urban Land designation indicates that a majority of the original soils on the site have been disturbed by development or covered with impervious surfaces, such as buildings or pavement.
Geologic Data:
(EDR GeoCheck)
The geologic formation in the vicinity of the Property is described as the Cenozoic era, Quaternary System, and Quaternary Series.
Prior Env. Reports:
(Section 3.2)
Prior environmental reports reviewed as part of this assessment, as detailed in Section 3.1, provided the following pertinent detail of physical setting data:
- The Subject Site is located within the San Gabriel Groundwater Basin.
Groundwater in this basin is present within the alluvial deposits and flows from the San Gabriel Mountains.
- Groundwater is estimated to be approximately 18 feet below ground surface.
Additional
Sources/ Data:
No additional physical setting sources or data was obtained.
Groundwater Flow
Discussion:
Based on a review of the above information as well as observation of the site, the direction of shallow groundwater flow at the site is inferred to be towards the southwest.
Federal, State and Tribal Environmental Record Sources
Standard government records were obtained and reviewed primarily via a third-party regulatory database report, titled EDR Radius Map™ Report, prepared by Environmental Data Resources of Shelton, CT. The report provided government records from the standard environmental resources and within minimum search distances specified by Section 8.2.2-Table 2 of the ASTM E1527-21; and were reviewed for the purpose of identifying potential RECs in connection with the Subject Property. Additional detail of the source and significance of the regulatory databases can be found in the regulatory database report in Appendix E. Hillmann has also included discussion of records pertaining to the Subject Property from other government record sources not specifically listed under Table 2, as applicable.
Reported distances for adjoining property listings, if applicable, are approximate and indicative of the presence of a public roadway or right-of-way between the adjoining site and Property.
The reported gradients have been estimated based on a number of factors including but not necessarily limited to field observation, review of topographic maps, database listing details and/or site specific geo-technical data.
Phase I Environmental Site Assessment -19- C3-10154
Limited analysis of the details of on-site, adjoining and vicinity database sites was conducted to identify potential sources of sub-surface vapor encroachment. This review was based on elements of the ASTM “Standard Guide for Vapor Encroachment Screening on Property Involved in Real Estate Transactions” (ASTM E 2600-15); and also on elements of “Methodology for Identifying the Area of Concern Around a Property Potentially Impacted by Vapor Migration from Nearby Contaminated Sources” (Buonicore, 2011-S-103-AWMA). Vicinity database sites pertaining to non-petroleum product releases within 1,760 feet of the Subject Property in the up-gradient direction, 365 feet of the Subject Property in the cross gradient direction and 100 feet of the Subject Property in the down gradient direction; and vicinity database sites pertaining to petroleum product releases within 528 feet of the Subject Property in the up-gradient direction, 165 feet of the Subject Property in the cross gradient direction and 100 feet of the Subject Property in the down gradient direction were reviewed to identify active contamination sites with the potential to affect subsurface vapor conditions at the Subject Property. The potential for vapor encroachment was considered in assessing whether or not a REC exists in connection with the Subject Property when reviewing applicable sites within those distances.
Regulatory database sites with active petroleum or non-petroleum releases that are considered to constitute a vapor encroachment condition (VEC) to the Subject Property, if any, are identified and discussed in this section.
The EDR Radius Map report is attached in Appendix D.
Subject Property Listings
The following listings of the Subject Property were identified:
Name/Address: Elite Salon Service/ 14420 Valley Boulevard Database(s): CERS, CPS-SLIC, WIP
Data Discussion: The CERS listing indicated the site on the Subject Property is registered as a Cleanup Program Site with a Site ID of “602467” and a CERS ID of “T10000014227.” The CPS-SLIC listing indicated the site Elite Salon Service was investigated in the 1990s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination. There was no indication of an actual reported release. the case was granted "Completed - Case Closed" status on December 16, 1996. Based on the details provided above, a REC is not suspected in connection with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: GM AUTO PAINT #3/ 14414 Valley Boulevard
Database(s): CERS, CERS HAZ WASTE, FINDS, ECHO, HWTS, HAZNET, RCRA NONGEN/NLR Data Discussion: The CERS and CERS HAZ WASTE listings indicated the site on the Subject Property is registered as a Chemical Storage Facility and a Hazardous Waste Generator with a Site ID of “571683” and a CERS ID of “10863403.” The CERS listing indicated the site had multiple administrative violations for failure to maintain proper Best Management Practices (BMPs) for hazardous materials.
Phase I Environmental Site Assessment -20- C3-10154
No spills were reported for the site. The ECHO and FINDS listings indicated the site is registered on the RCRA databases with a registry ID of "110070412354".
The HWTS listing indicated the site is registered as a hazardous waste transfer site. The permit was created on July 24, 2013, and is listed as "Active". The HAZNET listing indicated the following waste streams on the site: Unspecified solvent mixture, that was disposed of through fuel blending prior to energy recovery at another site. The RCRA NONGEN/NLR listing indicated the site is registered as a non-generator of hazardous wastes since July 24, 2013, with an EPA ID of “CAL000387730.” No releases or violations were noted for the site. Given the lack of reported spills or releases, these listings are not considered to be REC in connection with the Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Rico Products Inc. Duraware Plastics Co. /14412 Valley Boulevard Database(s): FINDS, CERS, CPS-SLIC, CHMIRS, WIP
Data Discussion: The FINDS listing indicated the site on the Subject Property is registered on the National Compliance Database (NCDB) database with a registry ID of "110011646102". The CERS listing indicated the facility on the Subject Property was registered as a Cleanup Program Site with a Site ID of “602373” and a CERS ID of “T10000014239.” The CPS-SLIC listing indicated the former occupant Duraware Plastics Co. was investigated in the 1980s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination. There was no indication of an actual reported release. The case was granted "Completed - Case Closed" status on August 11, 1987. The CHMIRS listing indicated the site had a release on March 18, 2021.
According to the listing, the release was of diesel exhaust fluid to the road, as a result of a multi-vehicle collision. The listing reported a release of 10 gallons that was cleaned up by the tow company onsite, and that no waterways or storm drains were effected. Based on the details provided above, a REC is not suspected in connection with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: C & N Office Specialties Inc./ 166 S. 6th Avenue Database(s): FINDS, ECHO, HWTS, HAZNET, RCRA-SQG,
Data Discussion: The ECHO and FINDS listings indicated the site on the Subject Property is registered on the RCRA databases with a registry ID of "110002762993". The HWTS listing indicated the site was previously registered as a hazardous waste transfer site. The permit was created on October 26, 2018, and is listed as inactive since July 27, 2018. The HAZNET listing indicated the following waste streams for the site: halogenated solvents (chloroforms, methyl chloride, perchloroethylene, etc.), Oxygenated solvents (acetone, butanol, ethyl acetate, etc.), and unspecified solvent mixture. These materials were disposed of through a recycler or incinerated. The RCRA-SQG listing indicated the site is registered as a non-generator of hazardous wastes since April Phase I Environmental Site Assessment -21- C3-10154
13,1987 and with an EPA ID of “CAD981979628.” No spills or violations were reported. Based on the absence of reported releases or violations, these listings are not considered to be a REC in connection with the Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Hunsaker Management, Cal Tex Precision Inc., Victory Coating/ 190 S. 6th Avenue
Database(s): HWTS, HAZNET, FINDS, CERS, CPS-SLIC, CERS HAZ WASTE Data Discussion: Hunsaker Management: The HWTS listing indicated the site on the Subject Property was previously registered as a "Hazardous Waste Transfer" site. The permit was created on April 9, 1999, and is listed as "Inactive" since December 01, 2003. The HAZNET listing indicated the following waste streams for the site: unspecified solvent mixture, and Off-specification, aged or surplus organics. These materials were disposed of through a transfer station. No spills or violations were reported. Based on the absence of reported releases or violations, these listings are not considered to be REC in connection with the Property.
Cal TEX Precision Inc.: The FINDS listing indicated the site on the Subject Property is registered on the RCRA databases with a registry ID of "110066058385". The CERS HAZ WASTE listing indicated the facility on the Subject Property was registered as a "Hazardous Waste Generator" with a Site ID of “14966” and a CERS ID of “10289614.” The CERS HAZ WASTE listing indicated the site had multiple administrative violations for failure to maintain proper Best Management Practices (BMPs) for hazardous materials. Based on the absence of reported releases or violations, these listings are not considered to be REC in connection with the Property.
Victory Coating, Inc.: The CERS listing indicated the facility on the Subject Property was registered as a "Cleanup Program" site with a Site ID of “605255” and a CERS ID of “T10000014262.” Review of GeoTracker details indicate the site was investigated in the 1980s under a "Well Investigation Program", to identify potential responsible parties to regional groundwater contamination.
There was no indication of an actual reported release. The case was granted "Completed - Case Closed" status on February 5, 1987. Based on the regulatory oversight, these listings are not considered to be REC in connection with the Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Multi-Color Tech LLC, 6 sign Inc./ 136 S. 6th Avenue Database(s): FINDS, ECHO, NPDES, CIWQS, CERS
Data Discussion: Multi-Color Tech LLC: The ECHO and FINDS listings indicated the site on the Subject Property is registered on the RCRA databases with a registry ID of "110070266596".
Phase I Environmental Site Assessment -22- C3-10154
6 Sign Inc.: The CERS, CIWQS, and NPDES listings indicated that the site on the Subject Property maintains an "Industrial Facility Stormwater" permit that has remained "Active" as of March 17, 2021. The facility has a Site ID of " 578042" and a CERS ID of "890556".
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Titto Inc., Benson Printers/ 172 S. 6th Avenue Database(s): CERS, HAZNET, HWTS
Data Discussion: The CERS listing indicated the site on the Subject Property is registered as a Chemical Storage Facility with a Site ID of “547728” and a CERS ID of “10286908.” The CERS listing indicated the site had multiple administrative violations for failure to maintain proper Best Management Practices (BMPs) for hazardous materials. No spills were reported for the site. The HWTS listing indicated the site is registered as a "Hazardous Waste Transfer" site. The permit was created on February 14, 1994, and is listed as "Inactive" as of December 31, 1999. The HAZNET listing indicated the following waste streams on the site: Unspecified organic liquid mixture, that was disposed of through fuel blending prior to energy recovery at another site. No releases were noted for the site. Given the lack of reported spills or releases, these listings are not considered to be REC in connection with the Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Atkinson Construction/ 148 S. 6th Avenue
Database(s): HWTS, HAZNET
Data Discussion: The HWTS listing indicated the site on the Subject Property is registered as a "Hazardous Waste Transfer" site. The permit was created on October 20, 2008, and is listed as "Inactive" as of June 30, 2012. The HAZNET listing indicated the following waste streams on the site: Other organic solids, off-specification, aged or surplus organics, and unspecified oil-containing waste. These materials were disposed of through storage, bulking, and/or transferred off-site with no treatment or recovery. No releases or violations were noted for the site. Given the lack of reported spills or releases, these listings are not considered to be REC in connection with the Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Lawrence Wire Cloth Inc./ 178 S. 6th Avenue Database(s): CERS
Data Discussion: The CERS listing indicated the site on the Subject Property is registered as a Chemical Storage Facility with a Site ID of “396354” and a CERS ID of “10295218.” The CERS listing indicated the site had multiple administrative violations for failure to maintain proper Best Management Practices (BMPs) for hazardous materials.
Phase I Environmental Site Assessment -23- C3-10154
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Adjoining Property Listings
The following adjoining property listings were identified.
Name/Address: Southern California Sanitation/ 163 S. 6th Avenue Database(s): HWTS, CERS HAZ WASTE, CERS TANKS, LOS ANGELES CO. HMS, HAZNET, CERS,
RCRA NONGEN/NLR
Dist./Dir./Gradient: 123 Feet/ West/ Down-gradient
Data Discussion: The CERS HAZ WASTE and CERS TANKS listing indicated the site is a Hazardous Waste Generator with CERS ID “10863556” and manages aboveground storage tanks. The HAZNET listing indicated the following waste streams for the site: Other organic solids, and unspecified oil-containing waste. These materials were stored/bulked and then transferred off-site with no recovery, for disposal. The HWTS listing indicated the property as a hazardous waste transfer site from December 21, 1998, to June 30, 2001. The HAZNET listing indicated the following waste streams for the site: Other organic solids, and unspecified oil-containing waste that were stored/bulked then transferred offsite with no recovery. The RCRA NONGEN/NLR listing indicated the site as a non-generator of hazardous wastes since January 7, 2008, with an EPA ID of “CAR000122390.” Based on the details provided above, a REC is not suspected in connection with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Former Patterson Resources/ 161 S. 6th Avenue Database(s): CERS, CPS-SLIC, WIP
Dist./Dir./Gradient: 125 Feet/ West/ Down-gradient
Data Discussion: The CERS listing indicated the site is registered as a Cleanup Program Site with a Site ID of “209015” and a CERS ID of “SL603798557.” The CPS-SLIC listing indicated the site known as the Former Patterson Resources had a release and was granted a "Completed - Case Closed" status on October 23, 2009. According to the CPS-SLIC listing and the online Geotracker Database in 1989, several soil and groundwater investigations were conducted on the site to characterize the historical activities of heavy equipment use, repair, and storage, as well as welding and component building at the Subject facility.
According to the "No Further Action" letter, prepared by the RWQCB and dated October 23, 2009 "From 1989 to 1992, environmental assessment activities substantiated soil impact from prior releases at concentrations up to 48,900 milligrams per kilogram (mg/kg) of TRPH and 0.635 mg/kg of tetrachloroethene (PCE). As a result of subsequent soil excavations and off-site disposal, the highest TRPH soil concentrations were reduced to 4 7 mg/kg onsite. In addition, in January 1992, soil gas investigations revealed 1, 1, 1: trichloroethane (1, 1-TCA) contamination up to concentrations of 1,045 micrograms per liter (ug/L) and for Phase I Environmental Site Assessment -24- C3-10154
PCE up to 219.8 flg/L in a small area in the southeastern portion of the site, immediately adjacent to an off-site drum storage area used by the EEMUS Manufacturing facility. From 1996 through 1997, EEMUS operated a soil vapor extraction (SVE) system, which successfully remediated the shallow impacted soil along the northern portion of the EEMUS facility. Based on these results, the Regional Board issued a "No Further Action" (NFA) letter to EEMUS dated May 30, 1997. In October ~ 2001, a subsequent soil gas survey indicated no detectable concentrations of VOCs in soil gas samples collected beneath the existing warehouse/distribution building, and low concentrations of VOCs (up to 5.8 flg/L of PCE, 4.9 flg/L of 1,1,1-TCA, and 1.8 flg/L of 1,1-DCA in the samples collected in the southern portion of the site currently occupied by an outside loading dock). The only groundwater contaminant discovered beneath the site was PCE at low concentrations up to 0.73 ug/L. " The RWQCB granted the site case closure on October 23, 2009. Based on the regulatory oversight, and positioning of the site in reference to the Subject Property these listings are not considered a REC in association with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Burnham Service Corporation, Rice Field Corporation, Orange County Container/ 14500 Valley Boulevard
Database(s): CERS, CERS HAZ WASTE, CPS-SLIC, LOS ANGELES CO. HMS, , FINDS, EMI,
HAZNET, HWTS, RCRA NONGEN/NLR
Dist./Dir./Gradient: 40 Feet/ East/ Up-gradient
Data Discussion: Rice Field Company: The CERS listing indicated the site is registered as a "Chemical Storage Facility" and a "Hazardous Waste Generator" with a Site ID of “147705” and a CERS ID of “10285069.” The CERS listing indicated the site had multiple administrative violations for failure to maintain proper Best Management Practices (BMPs) for hazardous materials. The HWTS listing indicated the site is registered as a "Hazardous Waste Transfer" site. The permit was created on June 9, 20120 and is listed as "Active". The HAZNET listing indicated the following waste streams on the site: waste oil and mixed oil that was stored/bulked then transferred offsite with no recovery, for disposal or that was recovered using organic recovery. The RCRA NONGEN/ NLR listing indicated the site as a non-generator of hazardous wastes since June 9, 2010, with an EPA ID of “CAL000353161.”
Burnham Service Corporation: The HWTS listing indicated the site is registered as a "Hazardous Waste Transfer" site. The permit was created on February 24, 1992, and is "Inactive" as of June 30, 1997. The CPS-SLIC listing indicated the site had a release and was granted a "Completed - Case Closed" status on July 15, 1987. No other pertinent information was provided.
Orange County Container: The FINDS and EMI listings indicated the site is registered with the South Coast Air Quality Management District for air emissions with a Registry ID of "110013829063." The CERS listing indicated the site is registered as a US EPA Air Emission Inventory System (EIS) with a CERS ID of "110013829063".
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
Phase I Environmental Site Assessment -25- C3-10154
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: Former Packaging Corporation, Hilltop Mini-Mart, Pactiv Corp./14505 Proctor Avenue
Database(s): CERS, CIWQS, DEED, CPS-SLIC, HIST CORTESE, AST, RCRA-SQG Dist./Dir./Gradient: 700 Feet/ Southeast/ Cross/Down-Gradient Data Discussion: The CERS listing indicated the site is registered as a "Cleanup Program" site with a CERS ID of "SL0603776483". The EMI listing indicated the site is registered with the South Coast Air Quality Management District for air emissions with a facility ID of "43046". The AST listing indicated the site previously managed an AST; however, no other pertinent information was provided. The CPS-SLIC listing indicated the site known as the former Packaging Corporation and located approximately 700 feet to the southeast and cross/downgradient of the Subject Property had a release and was granted a "Completed - Case Closed" status on August 21, 2012. According to the CPS-SLIC listing and the online Geotracker Database the site has been used for plastics manufacturing since the 1970's. Soil and groundwater assessments are complete. Vapor extraction has been used to mitigate concentrations of ethylbenzene and stryene in soil. Hillmann reviewed the most recent Phase II report dated May 8,2012 and the "No Further Action" letter from the RWQCB dated August 21, 2012. The letter stated the following, " Based on staffs review of the information on source removal, confirmation soil sampling after the implementation of bioventing, and acceptable risk assessment determinations for the Site, the Executive Officer of the Regional Board has determined that Pactiv Corporation has fulfilled the requirements for site assessment and soil cleanup criteria for an industrial and commercial land use scenario - the current designated zoning. The Regional Board has determined that "No Further Action"(NFA) is required with respect to the site. The NF A determination for this site is made at this time based upon the most current information/data contained in the subject file. The NFA applies only to the known chemicals of concern which have been tested during the site assessment phase of work and with the provision that the information provided to the Regional Board staff is accurate and representative of site conditions. If new contamination is encountered during future site construction or redevelopment activities, you are required to provide a verbal notification to this Regional Board immediately and submit a follow-up written report within 72-hours." The RWQCB granted the site "Case Closure" on August 21, 2012.
In May 2024 Hillmann performed a Limited Phase II Subsurface Investigation in order to address concerns of potential contamination on the Subject Property from nearby sources. The investigation included twenty-one (21) soil borings and installing a total of twenty (20) soil gas probes on the Subject Property. Hillmann reported the following conclusions:
"The results from soil sampling indicated no detectable concentrations of petroleum hydrocarbons and no heavy metals concentrations greater than current residential or commercial screening levels. The results from PFAS testing beneath the burned former building indicate many of these compounds were detected, but none at significant concentrations. The results from soil gas sampling indicate very low concentrations of VOC in some samples, none greater than current commercial screening levels."
"Based on these results, no additional sampling is recommended for the site." Phase I Environmental Site Assessment -26- C3-10154
Based on the available database details and the findings of the limited subsurface investigation these listings are not considered to be a REC in connection with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Name/Address: HEXCEL - MCI SITE, Hexcel Corp. Advance Products Div./ 140 N. Orange Avenue
Database(s): CERS, CPS-SLIC, FINDS, ECHO, HIST UST, RCRA-SQG Dist./Dir./Gradient: 305 Feet/ Northwest/ Cross/ Up-gradient Data Discussion: The CERS listing indicated the site is registered as a "Cleanup Program" site with a CERS ID of "SL603792633." The FINDS and ECHO listings indicate that the site is listed on the US EPA TRIS and RCRA databases with a Registry ID of "110002143216". The EMI listing indicated the site is registered with the South Coast Air Quality Management District for air emissions with a facility ID of "43046". The HIST UST listing indicated the site previously managed a 1000-gallon concrete UST that held liquid wastes from metal working. The tank was installed in 1984. The CPS-SLIC listing indicated the site had a release and was granted a "Completed - Case Closed" status on May 2, 2013.
According to the CPS-SLIC listing and the online Geotracker Database in 1986, several soil and groundwater investigations were conducted on the site to characterize the historical activities of metal fabrication, heavy equipment use, repair, and storage, as well as the use of PCE as a degreaser in industrial operations. According to the "No Further Action" letter, prepared by the RWQCB and dated May 1, 2013 "Soil Vapor Extraction (SVE) was implemented at the Site between 1989 and 2001 to remediate the impacted soil; air sparging was used to remediate impacted groundwater beneath the Site during 2000 and 2001.
Hexcel Corporation entered into the "Acorn Consent Decree" in December 2002.
The Consent Decree resolved Hexcel's Superfund liability with regard to the Puente Valley Operable Unit (PVOU) of the San Gabriel Valley Groundwater Basin. An interim remedy for PVOU groundwater is overseen by the US Environmental Protection Agency (USEPA)…Based on the staff's review of the information on source removal, confirmation soil sampling, and acceptable risk assessment determinations for the Subject Property, Regional Board staff has determined that the subsurface contamination at the subject property has been cleaned up to standards typically acceptable for industrial and commercial land use. Therefore, a "No Further Requirement" (NFR) status for soil only is granted to the property." The RWQCB granted the site "Case Closure" on May 2, 2013. Based on the regulatory oversight, and positioning of the site in reference to the Subject Property and 2023 Limited Subsurface Investigation findings, these listings are not considered a REC in association with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Phase I Environmental Site Assessment -27- C3-10154
Surrounding Area Findings
The following is a discussion of non-adjoining sites identified as located within the ASTM specified search distance surrounding the Subject Property. In order to keep this discussion informative and concise, discussion(s) is/are provided of the listed site(s) for each database category that appears most likely to impact the Subject Property based on distance, area topography and/or regulatory status. Listings of sites within the applicable search distances not specifically discussed below were reviewed and concluded not to be RECs in connection with the Subject Property or VECs based on various factors including distance, area topography, known or inferred groundwater flow direction and/or regulatory status.
Federal - NPL
ASTM Search Distance: 1-mile Number of listings within ASTM Search Distance: 2 Notable Listing: San Gabriel Valley (Area 4)/ Stimson Avenue & Old Valley Boulevard Dist/Dir/Gradient: TP
Details: Puente Valley is one (1) of eight (8) operable units (OUs) identified by the U.S. Environmental Protection Agency (USEPA) for the San Gabriel Valley Superfund Site and is also known as San Gabriel Valley Superfund Site Area 4. The Puente Valley OU includes most of the City of Industry, portions of the City of La Puente, and portions of unincorporated Los Angeles County. Groundwater and soil are contaminated with various volatile organic compounds (VOCs, primarily trichloroethene (TCE) and tetrachloroethene (PCE)), 1,4-dioxane, perchlorate, and hexavalent chromium. Groundwater contamination occurs primarily in the shallow and intermediate groundwater zones of the aquifer, with most of the contaminant mass found in the shallow groundwater zone. VOC concentrations exceed drinking water standards in both the shallow and intermediate zones.
The USEPA issued the Interim Record of Decision (IROD) for the Puente Valley OU in September 1998 to address VOC-contaminated groundwater. In 2005 the USEPA issued an Explanation of Significant Differences to the IROD to address 1,4-dioxane and perchlorate. The interim remedy includes extraction, containment, and treatment of contaminated groundwater in the shallow and intermediate zones at the mouth of Puente Valley. The remedy also includes wells for monitoring groundwater in the shallow, intermediate, and deep zones at mid-valley and the mouth of the valley to ensure that the remedy meets performance criteria set in the IROD.
While multiple individual facilities may have contributed to contamination in the area, there are two (2) work parties responsible for implementing the cleanup plan under USEPA oversight: Carrier Corporation (and its parent company, United Technologies Corporation) and Northrop Grumman Corporation. Carrier Corporation is required to implement groundwater cleanup actions for the shallow zone north of Puente Creek under a consent decree. Northrop Grumman is required to implement groundwater cleanup actions for the intermediate zone and Phase I Environmental Site Assessment -28- C3-10154
for the shallow zone south of Puente Creek under a consent decree and Unilateral Administrative Order, respectively. The total cost of the remedy is estimated to be $75 million.
Three (3) ground water extraction and treatment systems are planned to protect the water supply in the mouth of Puente Valley and to prevent further contaminant movement. Completion of the systems was delayed identifying and evaluate additional options for discharge and conservation of treated water, and to design treatment systems capable of treating the identified contaminants.
For the cleanup project, known as the “Shallow Zone-North” remedy, construction of a network of ten (10) groundwater extraction wells was completed in 2007. The project will clean up contaminated shallow groundwater north of Puente Creek. Construction of the treatment plant will begin after agreements are reached for discharge of the treated water.
Design and construction of the project known as the “Intermediate Zone” remedy, should be completed by 2019. This project will clean up deeper, less contaminated groundwater in the mouth of Puente Valley. Six (6) extraction wells have already been constructed for the Intermediate Zone Remedy, and one (1) or two (2) more may also be constructed. The extracted water will be treated using several technologies to address all the contaminants of concern. Granular activated carbon will be used to treat for volatile organic contaminants, advance oxidation will be used to treat 1,4-dioxane, ion exchange will be used to treat for perchlorate and reverse osmosis will be used to inorganics to meet drinking water standards.
The “Shallow Zone South” Remedy will address groundwater contamination in the shallow zone south of Puente Creek.
Based on a review of groundwater quality data indicated by a 2017 monitoring report for Puente Valley Operable Unit-Shallow Zone North Remedy, monitoring wells installed within the shallow groundwater zone on adjoining properties to the southeast and northwest (MW-13 and MW-14) indicated zero to minimal concentrations of VOCs below MCLs, and depths to groundwater of approximately 50 to >60 feet below grade.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Federal - Delisted NPL
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 0 Notable Listing: No listings were identified within the search distance.
Dist/Dir/Gradient:
Details:
Phase I Environmental Site Assessment -29- C3-10154
REC Discussion:
VEC Discussion:
Federal - SEMS
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 3 Notable Listing: Lucas Site/ 14723 East Proctor Avenue
Dist/Dir/Gradient: 2051 Feet/ Southeast/ Cross-gradient Details: The SEMS listing indicated the site is currently not on the NPL list and is currently addressed as a part of another non-NPL site. The EPA ID for the site is " CAD983670555".
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Federal - SEMS Archive
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 1 Notable Listing: Ecobat Resources California Inc.
Dist/Dir/Gradient: 3799 Feet/ South-southeast/ Down-gradient Details: The SEMS-Archive listing indicated the site is not on the NPL list.
According
to the listing, the site has a non-NPL status of "NFRAP" which means the site does not qualify for the NPL based on existing information.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
Federal - CORRACTS
ASTM Search Distance: 1-mile Number of listings within ASTM Search Distance: 0 Notable Listing: No listings were identified within the search distance.
Dist/Dir/Gradient:
Details:
REC Discussion:
VEC Discussion:
Federal - RCRA-TSD
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 0 Notable Listing: No listings were identified within the search distance.
Dist/Dir/Gradient:
Details:
Phase I Environmental Site Assessment -30- C3-10154
REC Discussion:
VEC Discussion:
State/Tribal - Superfund / Hazardous Waste Sites
ASTM Search Distance: 1-mile Number of listings within ASTM Search Distance: 9 Notable Listing: Exide Technologies/ GNB Battery/ 14500 Nelson Avenue Dist/Dir/Gradient: 1142 Feet/ Northeast/ Up-gradient
Details: The ENVIROSTOR listing indicated the site is currently an "Evaluation" site but is not listed on the NPL list. The site is listed as "Refer:1248 Local Agency" as of January 25, 2006. No other pertinent information was provided.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
State/Tribal - Landfill / Solid Waste Disposal
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 4 Notable Listing: Arrow Disposal Services Inc./ 14245 Proctor Avenue Dist/Dir/Gradient: 1127 Feet/ West/ Down-gradient
Details: The SWF/LF listing indicated the site is an "Active Waste Hauler" with Facility ID/ SWIS Number “19-AS-0087”. No other pertinent information was provided. Based on the absence of reported releases or violations, this listing is not considered to be a REC in connection with the Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
State/Tribal - Leaking Storage Tanks
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 12 Notable Listing: Hansen Foods/ 14380 Nelson Avenue
Dist/Dir/Gradient: 304 Feet/ Northeast/ Up-gradient
Details: The LUST listing indicated the site reported a release of solvents on April 11, 1990, during UST removal operations. The LUST was given a "Completed - Case Closed" status on September 17, 1997. Hillmann reviewed the "No Further Requirements" letter prepared by the RWQCB and dated, June 29, 1998. According to the letter the site previously managed five (5) USTs, unlined settling pits, surface drainage channels, and a three-stage clarifier that were decommissioned and removed from the site on April 11, 1990. The RWQCB letter states the following "Diesel, volatile organic compounds (VOCs), and hydrochloric/ lead acid-impacted soil were excavated and properly disposed of off-site between 1990 and 1994. Discovery of peak concentrations in the soil of 1, 1-DCE (17 ~glkg) and I, I, 1-TCA (670 ~glkg), where VOCs were stored in drums along the Phase I Environmental Site Assessment -31- C3-10154
northeastern property boundary, was promptly remediated to non-detect levels through soil vapor extraction technology. The data did not indicate a track of contaminants from the vadose zone to groundwater. The groundwater monitoring results for the December 1997 sampling period show non-detects to low concentrations of VOCs.
The highest concentration detected was 43 ~giL of TCE, a chemical reportedly not used onsite based on historical records. This chemical may have emanated from off-site sources. Based on these findings, Regional Board staff concludes that the work performed to date at your facility adequately has fulfilled our assessment and remediation requirements. As a result, no further requirements need to be met with respect to the San Gabriel Superfund Cleanup Program. Please maintain your groundwater monitoring wells in operable condition to allow for future use in relation to regional sampling and/or cleanup activities." Based on regulatory oversight, this listing is not suspected to be a REC in connection with the Subject Property.
REC Discussion: Based on the details provided above, a REC is not suspected in connection with the Subject Property.
VEC Discussion: Based on the reviewed data, a VEC is not suspected.
State/Tribal - Voluntary Cleanup Sites
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 0 Notable Listing: No listings were identified within the search distance.
Dist/Dir/Gradient:
Details:
REC Discussion:
VEC Discussion:
State/Tribal - Brownfields
ASTM Search Distance: 1/2-mile Number of listings within ASTM Search Distance: 0 Notable Listing: No listings were identified within the search distance.
Dist/Dir/Gradient:
Details:
REC Discussion:
VEC Discussion:
Unmapped/Orphan List Sites
Hillmann has also reviewed a list of unmapped sites (a.k.a. “Orphan List” sites) indicated by the database report. Unmapped sites that were identified as falling within an applicable specific search distance or warranting discussion have either been discussed in the preceding tables or are detailed below:
Name/Address:
Phase I Environmental Site Assessment -32- C3-10154
Database(s):
Dist./Dir./Gradient:
Data Discussion:
REC Discussion:
VEC Discussion:
Additional Environmental Record Sources
Requests have been submitted to local, municipal and state agencies for pertinent records pertaining to the Subject Property, particularly with regard to potential environmental concerns such as petroleum storage tanks, storage and usage of hazardous substances and petroleum products, and/or known or suspected environmental contamination. Where applicable, internet research of government environmental regulatory databases was also conducted, as well as a general cursory internet search of the Subject Property address, for information indicative of a REC. The following table summarizes the findings of the research:
Source
Type of
Request Outcome
www.realquest.co
m
Online
search
Hillmann reviewed available on-line records pertaining to the Property. No information indicative of a REC was identified.
CA DTSC
Envirostor
database
(www.envirostor.d
tsc.ca.gov/public/)
Online
search
Hillmann reviewed available on-line records pertaining to the Property.
Details of the Puente Valley/San Gabriel Valley NPL case including a 2017 shallow zone groundwater monitoring report, were reviewed.
No information indicative of a REC was identified.
CA GeoTracker
database
(geotracker.water
boards.ca.gov/)
Online
search
Hillmann reviewed available on-line records pertaining to the Property. The following pertinent records and/or information was obtained:
Hillmann reviewed the online GeoTracker database created by the RWQCB. The database showed three (3) separate cleanup programs that were completed and given a "Case Closure" on the Subject Property. Duraware Plastics Co. Inc. (RB Case #:
102.0066), Elite Salon Service (RB Case#: 102.0057), and Victory Coating Inc. (RB Case#: 102.0086). The cases are discussed further above in section 4.1 of this report.
EPA MyProperty Online
search
Hillmann searched online for records pertaining to the
Property. No records pertaining to the property were found.
South Coast Air
Quality
Management
District (SCAQMD)
FOI request A response was received providing the following pertinent records:
Hillmann reviewed the SCQAMD inspection reports for multiple addresses on the Subject Property. The inspection reports stated that the facility addressed as Victory Coating previously maintained a silk screen printing unit that utilized organic solvents. Additionally, the facility addressed as C & H Office Equipment previously managed a spray paint and solvent
booth that utilized organic solvents. As of 1994 all of the equipment is listed as inactive, and no violations were noted.
Phase I Environmental Site Assessment -33- C3-10154
Source
Type of
Request Outcome
Los Angeles Co.
Fire Dept./CUPA
FOI request A response was received providing the following pertinent records:
Hillmann reviewed several fire inspection reports for multiple addresses on the Subject Property beginning in 2015. The reports noted several violations of tenants on the Subject Property for failures to maintain the Best Management
Practices when handling, storing, or using hazardous
materials. No spills were reported within the fire inspection reports.
4.2 Historical Research
Historical records have been compiled and analyzed for historical property information and developing a history of previous uses of the Subject Property, adjoining properties and surrounding area. These records were reviewed for the purpose of identifying the likelihood of past uses having led to RECs in connection with the Subject Property.
The historical record sources listed below have been sought with the objective to document past uses of the Subject Property from the present back to the Subject Property’s first developed use, or back to 1940, whichever is earlier. The term “developed use” includes agricultural use, placement of fill dirt and other uses that do not involve structures. Hillmann has sought to review historical records in minimum intervals of five years.
Fire Insurance Maps
A Certified Sanborn Map Report was obtained from EDR for a review of published historical fire insurance maps for the Subject Property and surrounding area. The following is a summary of site uses and notable details depicted by the available maps:
Year(s) Subject Property Adjoining Properties
None None None
A copy of the Certified Sanborn Map Report is attached in Appendix E.
City Directories
An EDR City Directory Abstract report was reviewed for data of prior occupants of the Subject Property’s street address. The following is a generalized summary of the findings of city directory research for past occupants of the Subject Property.
Subject Property Use(s) / Occupant(s) Years
Various light industrial and commercial occupants. Notable listings are details 1982 - 2020 Durawear Plastics (14412 Valley) 1982, 1987
Printers Diversified Inc 1982, 1987
Glossit Mfg (14426 Valley) 1982
Phase I Environmental Site Assessment -34- C3-10154
Subject Property Use(s) / Occupant(s) Years
Color scan/Plate Ready Co (14420 Valley) 1982
C L W Plastic Bag Mfg (14422 Valley) 1987
D B W Data Machine Srvc/Printer Term Srvc (110 S. Sixth) 1987 Industry Color Graphics (138 S. Sixth) 1987
Tri Star Colr Sprth (122 S. Sixth) 1987, 1992
Benson Prnting Co. (132 S. Sixth) 1992, 1995
Victory Coatings (190 S. Sixth) 1992, 1995
Graphic Service (132 S. Sixth) 1992, 1995
American Speedy Printing Center (14426 Valley) 1992, 1995 Wonderful World Prnt (14414 Valley) 1992
Alpha & Omega Printing (126 S. Sixth) 2010
VC Screenprinting Inc. (190 S. Sixth) 2014
Central Truck & Oil Supply (14426 Valley) 2014
The EDR City Directory Abstract report was also reviewed for listings of prior occupants of the adjoining properties. The following is a generalized summary of the findings of city directory research for past occupants of the adjoining properties:
Adjoining Property Use(s) / Occupant(s) Years
Mix of residential and commercial occupants. Commercial occupants included gasoline service stations.
1961 - 1976
Mix of light industrial and commercial. 1982 - 2020
A copy of the EDR City Directory report is attached in Appendix E.
Historical Topographic Maps
Historical topographic maps of the Property and vicinity obtained from an EDR Historical Topographic Map report (as attached in Appendix E) have been reviewed. The following interpretation of land usage was made by review of the maps:
Year(s) Subject Property Adjoining Properties
1894, 1897,
1898, 1904
The Subject Property is depicted as
undeveloped land.
The adjoining properties to the east,
west, and south are all depicted as
undeveloped land. North of the Subject
Property the Southern Pacific Railroad is
mapped.
1927 The Subject Property is depicted as
undeveloped land.
The adjoining properties to the east and
south are all depicted as undeveloped
land. West of the Subject Property a
structure is depicted. North of the
Subject Property an improved road is
Phase I Environmental Site Assessment -35- C3-10154
Year(s) Subject Property Adjoining Properties
depicted as Pomona Boulevard. Further
north of the Subject Property, the
Southern Pacific Railroad is mapped.
1953 The Subject Property is depicted with a
structure located on the northwestern
corner of the property. The remaining area
is depicted as undeveloped land.
The adjoining properties to the east and
south are all depicted as undeveloped
land. West of the Subject Property a
structure is depicted. North of the
Subject Property an improved road is
depicted as Valley Boulevard. Further
north of the Subject Property, the
Southern Pacific Railroad is mapped.
1966 The Subject Property is depicted as
undeveloped land.
The adjoining properties to the north,
west, and east of the Subject Property
are all depicted with several structures.
South of the Subject Property is
depicted
as undeveloped land.
1972 The Subject Property is depicted as
undeveloped land.
The surrounding properties are
depicted
with several structures.
1981 The Subject Property is depicted as
developed with seven (7) structures.
The surrounding properties are
depicted
with several structures.
2012, 2015,
2018
No improvements or structures are
depicted on this topographic map.
No improvements or structures are
depicted on this topographic map.
If obtained, copies of historical aerial photographs have been included in Appendix E.
Historical Aerial Photographs
Historical aerial photographs of the Property and vicinity obtained from an EDR Aerial Photo Decade Package report, as attached in Appendix E, were reviewed. The following interpretation of land usage was made by review of the aerial photographs:
Year(s) Subject Property Adjoining Properties
1928 The Subject Property appears to be
agricultural land developed as furrowed
fields. No structures are noted on the
Subject Property.
The adjoining properties appear to be
agricultural land. North of the Subject
Property there appears to be a railway.
1938, 1948,
1952
The Subject Property appears to be
agricultural land developed as furrowed
fields. No structures are noted on the
Subject Property.
The adjoining properties appear to be
agricultural land. North of the Subject
Property there appears to be a railway.
The adjoining property to the west of
the Subject Property appears to have
several structures and various items of
equipment on the premises.
Phase I Environmental Site Assessment -36- C3-10154
Year(s) Subject Property Adjoining Properties
1964 The Subject Property appears to be
agricultural land developed as furrowed
fields. There appears to be a small
structure located on the northeastern
corner of the Subject Property.
The adjoining properties appear to be
agricultural land. North of the Subject
Property there appears to be a railway.
The adjoining property to the west of
the Subject Property appears to have
several structures and various items of
equipment on the premises.
1972,1977 The Subject Property appears to be under
development. There is a structure located
on the northeastern portion of the Subject
Property along with several items that
appear to be equipment
South of the Subject Property appears
to be agricultural land. East and north
of the Subject Property there appears to
be a light industrial area under
development. The adjoining parcel west
of the Subject Property appears to
have several structures and
unrecognizable
items and equipment throughout the
premises.
1981, 1983 The Subject Property appears developed
with several of the present-day commercial
structures on the property, as well as the
asphalt-paved parking areas.
The surrounding properties to the
south, east, and north all appear to
have large light industrial structures.
The adjoining parcel west of the Subject
Property appears to have several
structures and unrecognizable items
and equipment throughout the
premises.
1990, 2005,
2009, 2012,
2016, 2020
The Subject Property appears developed
with several of the present-day commercial
structures on the property, as well as the
asphalt-paved parking areas.
The surrounding properties all appear
to
have light industrial structures on the
premises.
If obtained, copies of historical aerial photographs have been included in Appendix E.
EDR High-Risk Historical Records
The EDR Radius Map™ report, which is discussed in greater detail in Section 4.1 and attached in Appendix D, provided a search of proprietary databases of potential historical high-risk uses at or in the vicinity of the Subject Property. These databases include EDR Hist Cleaner – a database of property addresses with records of historical occupancy by suspected cleaners businesses; EDR Hist Auto – a database of property addresses with records of historical occupancy by potential automotive gas/filling stations and repair facilities; and EDR MGP- a proprietary database of sites historically occupied by manufactured gas plants and related facilities.
EDR Database On-site Listings Adjoining/Off-site Listings EDR Hist Cleaner:
(on-site/adjoining
only)
None None
Phase I Environmental Site Assessment -37- C3-10154
EDR Database On-site Listings Adjoining/Off-site Listings EDR Hist Auto:
(on-site/adjoining
only)
None None
EDR MGP:
(1-mile distance)
None None
Petroleum/Natural Gas Well Review
No record of any historical petroleum/natural gas wells at or adjoining the Property was identified.The historical record sources and the California Geologic Energy Management Division (CalGEM) online mapping application were reviewed for records of petroleum and/or natural gas wells at the Subject Property.
Additional Historical Data
Where applicable, the following additional pertinent historical data was obtained:
Interviews/
Anecdotal:
No additional pertinent historical data was obtained.
Local Gov’t
Records:
No additional pertinent historical data was obtained.
Prior Env. Reports: Prior environmental reports reviewed as part of this assessment, as detailed in Section 3.1, did not provide additional pertinent detail of historical site usage.
Site Observations: Indications of historic uses of the Property or adjoining properties were not observed during the site reconnaissance.
Other Sources: No additional pertinent historical data was obtained.
Summary of Identified Historical Uses
The following table presents a summary of the types and approximate date ranges of identified prior uses of the Subject Property:
Date Range Subject Property Use(s)
1884 to 1927 Undeveloped Land
1928 to 1964 Agricultural furrowed fields
1972 to 1977 Vacant land with a structure
1981 to Present Mix of commercial and light industrial warehouses/offices The following table presents a summary of the types of identified prior uses of the adjoining properties:
Date Range Adjoining Property Use(s)
1894 to 1927 Agricultural
1938 to 1964 Mix of agricultural land and commercial/industrial properties Phase I Environmental Site Assessment -38- C3-10154
Date Range Adjoining Property Use(s)
1972 to present Mix of commercial and light industrial properties Historical Records Data Failure
The ASTM E1527-21 standard defines data failure as failure to achieve the historical research objective even after reviewing the standard historical sources that are reasonably ascertainable and likely to be useful. The objective is to identify all obvious uses of the Subject Property from the present, back to the Subject Property’s first developed use, or back to 1940, whichever is earlier. Furthermore, records of historical use/conditions were sought in intervals no less than approximately five years, unless the Subject Property conditions appear unchanged over a longer interval. In encountered, data failure and its significance as a data gap is discussed below:
Objective Met? Detail Significant?
First developed use/
date determined?
No The earliest documented use of the Property was
agricultural crop fields, circa 1928.
No
Record sources at
5-year intervals back to
1940 or first developed
use?
No Historical record gaps exceeding five years were
encountered. However, significant site-use
changes or undiscovered site uses appear unlikely
to have occurred during the record gaps.
No
All obvious prior uses
identified?
Yes See Summary of Identified Past Uses of this
section.
No
Please refer to Section 2.3 for additional discussion of data gaps and their significance to the findings of the assessment.
Historical Uses REC Discussion
The Subject Property has been utilized by multiple tenants for various light industrial operations since approximately 1977. Historical occupants included several printing/ graphics businesses, which are considered potentially high risk for environmental impacts. Other occupants included light manufacturing operations, machine servicing businesses, auto painting supplies, and oil supplies.
Hillmann performed a Limited Phase II Subsurface Investigation in May 2023 to address concerns of potential contamination on the Subject Property from historical uses and nearby offsite sources. Hillmann proposed a Limited Phase II Subsurface assessment that included twenty-one (21) soil borings and twenty (20) soil gas probes on the Subject Property.
The report indicated the following conclusions:
"The results from soil sampling indicated no detectable concentrations of petroleum hydrocarbons and no heavy metals concentrations greater than current residential or commercial screening levels. The results from PFAS testing beneath the burned former building indicate many of these compounds were detected, but none at significant Phase I Environmental Site Assessment -39- C3-10154
concentrations. The results from soil gas sampling indicate very low concentrations of VOC in some samples, none greater than current commercial screening levels." "Based on these results, no additional sampling is recommended for the site." Based on the findings of the 2023 Limited Subsurface Investigation, the historical uses of the Subject Property are not considered to be a REC in association with the Subject Property.
The Property was historically utilized for agricultural purposes from 1928 to 1964. Given the subsequent site redevelopment, the potential for concentrated pesticides in shallow soils is considered low; therefore, historical agricultural use is not considered a REC.
Phase I Environmental Site Assessment -40- C3-10154
5.0 INTERVIEWS
5.1 Interviews with Owners, Operators and Occupants
Property Owner
Property Owner Contact Name Affiliation Interview Type Date Richard C. Hunsaker Owner Questionnaire
Attempts were made via telephone and email (environmental questionnaire); however, no response was received.
Key Site Manager/Operator
Name Company/Title
Yrs @
Site Interview Type Date
None In person
A knowledgeable site representative was not identified or made available for interview.
Occupant(s)
Name Company/Title
Yrs @
Site Interview Type Date
(none)
No occupant interviews were conducted.
Prior Owners/Operators/Occupant(s)
Name Company/Title
Yrs @
Site Interview Type Date
(none)
No interviews of prior owners, operators or occupants were conducted.
Neighboring Property Owner(s)/Occupant(s)
Name Company/Title
Yrs @
Site Interview Type Date
(none)
The Subject Property was not an abandoned property with evidence of unauthorized uses or uncontrolled access; therefore, interviews with adjoining or nearby property owners or occupants were not conducted.
Phase I Environmental Site Assessment -41- C3-10154
5.2 Interviews with State and/or Local Government Officials State and/or local governmental officials have been interviewed to obtain information of potential RECs in connection with the Subject Property. Many government agencies and their officials require submittal of written request for records in order to respond. The details in Section 4.1 list the various state and local government agencies contacted as part of this assessment, and the outcome of each inquiry. In addition, the details of regulatory database research in Section 4.1 may have included detail of interviews with officials pertinent to government records review and identification of RECs.
Additional interview of government officials not previously detailed in Sections 4.1 are discussed below, if applicable.
Name Agency Name/Title Interview Type
(none)
Interview Outcome/Findings:
No additional local/state government officials were interviewed.
Phase I Environmental Site Assessment -42- C3-10154
6.0 SITE RECONNAISSANCE
6.1 Methodology and Limiting Conditions
A site reconnaissance was conducted to collect information and make observations to help identify RECs in connection with the Subject Property. This included visual and/or physical observations of the Subject Property and its structures, adjoining properties as viewed from the Subject Property boundaries and the surrounding area based on visual observations from adjoining public thoroughfares and accessed Subject Property structures. Subject property building exteriors were observed at ground level, unless otherwise indicated. Where applicable, building interiors were accessed and observed to the extent they were made safely accessible with the cooperation of the site escort.
Site Inspection
Personnel:
Kofi Bonner
Property Escort/
Company:
Unescorted/
Inspection Date: September 11, 2024
Weather Conditions: 87° F / Sunny
Significant Inaccessible Areas
The following significant areas of the Property were not accessed at the time of the site visit:
- Several of the tenant's units were unable to be accessed during site reconnaissance. The following units were not accessed:
East Valley Boulevard South 6th Avenue
- Unit 14410 - Unit 100
- Unit 14412 - Unit 102
- Unit 14414 - Unit 104
- Unit 14416 - Unit 108
- Unit 14422 - Unit 112
- Unit 14424 - Unit 114
- Unit 14428 - Unit 116
- Unit 14430 - Unit 118
- Unit 14436 - Unit 172
- Unit 178
- Unit 156
- Unit 160
- Unit 138
- Unit 136
- Unit 134
- Unit 132
- Unit 130
- Unit 128
- Unit 126
Phase I Environmental Site Assessment -43- C3-10154
- Unit 124
- Unit 122
- Unit 120
Significant Limiting Site Conditions
No significant limiting site conditions were noted at the time of the site reconnaissance.
6.2 General Site Setting
Site and Vicinity Characteristics
Abutting Roadways: Valley Boulevard to the northeast; South 6th Avenue to the northwest Current Property Use: Commercial/ lLight Industrial
Evidence of Past
Property Uses:
None
Evidence of Past
Adjoining Property
Uses:
None
Surrounding Area
Uses:
Light industrial warehouses
Current Adjoining Property Uses
Dir Street Address Description
N 240 North Orange
Avenue
Tropicana Products Inc. - Naked Juice Co.
E 14500 Valley Boulevard Rice Field Corporation
SE 14505 Proctor Avenue NFI Cal Cartage
S 102 -190 South 6th
Avenue
Various light industrial operations
SW 207 S 6th Avenue Dvenegas Designs
W 14350 Valley Boulevard Dukes Restaurant
Topographic Characteristics
Terrain: Flat
Direction of Downward
Slope:
Southwest
On-site Water Bodies: None
Other Significant
Features:
None
Phase I Environmental Site Assessment -44- C3-10154
General Description of Structures and Improvements
Buildings: Six
Approx. Building Size: 28,800 SF (Building A), 17,280 SF( Building B), 19,200 SF ( Building C), 12,800 SF (Fmr. Building D), 8,640 SF (Building E), 8,640 SF (Building F), 12,800 SF (Building G)
Approx. Year Built: 1977
Number of Stories: One
Subgrade Levels: None
Exterior Ground Cover: Asphalt Parking Lot, Landscaping, Ancillary Structures: Concrete pad of former building
Sources of Heating and
Cooling:
Electrical heating and cooling systems
Potable Water/Sewage
Disposal:
Municipal utility connections
6.3 Site Features and Conditions
Storage/Usage of Hazardous Substances and Petroleum Products The following approximate number of containers, and general description of their contents, capacity, container types and storage conditions, were observed to be stored and/or used at the Subject Property:
Occupant Substance Qty/Container Type Storage Conditions 3M MCS
Warranty
Multicolored Ink
for printers
Several cases of ink Stored on shelves within office area.
Sage
Wedding
Albums
All-purpose
Thinner
2/ 1-gallon containers Stored on floor of office workspace.
Sage
Wedding
Albums
Petroleum 1 portable no-spill
petroleum container
Stored on top of generator in
warehouse area.
Industry
Hoses &
Fasteners
Hydraulic oil Approx.15/ 5-gallon
containers
Stored on ground near entrance of
office area.
Industry
Hoses &
Fasteners
Brake fluid/
degreasing fluid
Various containers and
sizes
Stored within a hazardous materials
chest within warehouse area.
Industry
Hoses &
Fasteners
Liquid Petroleum
Gas
Approx. 2/ 8-gallon
metal drums
Stored on the ground near the hangar
doorway.
Attached to forklift equipment.
GM Auto Paint
Supplies
Spray Paint 50+ / 8-fl.oz containers Stored on shelves within office area.
GM Auto Paint
Supplies
Lacquer Thinner Approx. 10/ 5-gallon
containers
Stored on concrete underneath storage
shelves.
Phase I Environmental Site Assessment -45- C3-10154
Occupant Substance Qty/Container Type Storage Conditions GM Auto
Paint
Supplies
Various Paints 50+/ 32 -fl.oz
containers
Stored/In-use on shelves in the back
area of warehouse.
Bathplanet Silicone Sealent Approx. 30/ Silicone
Sealant tubes
Store on shelves within warehouse
area.
Bulk Petroleum/Hazardous Material Storage Tanks
If identified or suspected, storage tanks for bulk petroleum or hazardous material storage are described as follows:
AST/UST Product Capacity Construction
Year
Installed Status Location/Notes
None No storage tanks were
identified.
Strong, Pungent or Noxious Odors and their Sources
No strong, pungent or noxious odors were noted at the Subject Property.
Standing Surface Water/Pools & Sumps
No standing water, pools or sumps containing liquids likely to be hazardous substances or petroleum products were noted.
Drums, Totes and Intermediate Bulk Containers
No hazardous substance or petroleum product drums were noted.
Unidentified Substance Containers
No unidentified substance containers suspected of containing hazardous substance or petroleum product were noted.
PCBs in Oil Filled Electrical/Hydraulic Equipment
The following oil-filled electrical/hydraulic equipment was identified at the Property:
During site reconnaissance Hillmann observed two (2) utility owned oil-filled pad-mounted transformers on the Subject Property. The transformers appeared to be in good condition with no staining observed in their respective proximities.
It is noted that identification of PCB containing fluorescent light ballasts, caulk, paint, or other materials located inside and are part of the building or structure is outside of the scope of the ASTM E1527-21 standard and this assessment.
Phase I Environmental Site Assessment -46- C3-10154
Stains or Corrosion on Floors, Walls or Ceilings
No stains or corrosion of floors, walls or ceilings, excluding any staining from water, were noted.
Drains and Sumps
No floor drains or sumps were noted at the Subject Property.
Pits/Ponds/Lagoons
No pits, ponds or lagoons were identified in connection with waste treatment or disposal.
Stained Soil, Pavement/Stressed Vegetation
No stained soil, pavement or stressed vegetation was observed.
On-Site Solid Waste Disposal/Fill Material
The following evidence of on-site disposal of trash, construction debris, demolition debris or other solid waste was observed:
Consumer debris was noted in front of the 130 S t6th Avenue building. The debris appeared to be a mix of packing materials and consumer debris. No staining or spills were observed in proximity to the debris.
The Subject Property has several dumpsters that are serviced by Valley Vista Services Waste Disposal and Recycling services.
Waste Water
Sanitary sewage generated at the Subject Property is discharged via a connection to the local public sewer system.
Storm water runoff at the Subject Property is discharged via roof drains into the municipal sewer system.
No additional wastewater discharges were identified at the Subject Property.
Septic Systems/Cesspools
No septic systems or cesspools were identified at the Subject Property.
Wells
No wells (including any dry wells, irrigation wells, injection wells, abandoned wells, or other wells) were identified at the Subject Property.
Phase I Environmental Site Assessment -47- C3-10154
Railroad Spurs
No railroad spurs were identified on the Subject Property.
An offsite rail spur, apparently inactive, was observed adjoining the southeast side of the Subject Property.
Phase I Environmental Site Assessment -48- C3-10154
7.0 BUSINESS ENVIRONMENTAL RISKS
In accordance with the contract agreement for this assessment, Hillmann has performed cursory reviews of several potential Business Environmental Risks (also known as “Non-Scope Considerations”). The ASTM E1527-21 standard defines the term business environmental risk (BER) as, “a risk which can have a material environmental or environmentally-driven impact on the business associated with the current or planned use of a parcel of commercial real estate, not necessarily limited to those environmental issues required to be investigated in this practice.”
7.1 Asbestos-Containing Material (ACM)
The contracted scope of work included a cursory visual screening of the accessed portions of buildings at the Subject Property built prior to 1990 for suspect asbestos containing materials (ACM). The information provided in this section, where applicable, is limited to identification of potential suspect materials in the readily accessible and observed areas of the building, and their general condition. This is not intended to be a comprehensive survey for the presence of ACM, and no testing has been conducted.
Suspected ACM noted within the accessed building areas included vinyl sheet flooring, floor tiles and associated mastic, mirror mastic, carpeting and associated mastic, roofing systems, penetration mastics, and thermal systems insulation.
7.2 Lead-Based Paint
The contracted scope of work included a cursory visual screening of the condition of painted surfaces in the accessed areas of residential buildings/units built prior to 1980. This is not intended to constitute a comprehensive survey for LBP or potential lead hazards, and no testing has been conducted.
No residential buildings built prior to 1978 were present at the Property.
7.3 Radon
Data compiled by the USEPA, as summarized by the regulatory database report, indicated that the Subject Property is located in an area classified as Zone 2 or 'moderate risk'. area for radon.
Radon testing was not included in the scope of this assessment.
7.4 Mold/Microbial Damage
The contracted scope of work included a cursory visual screening of the accessed areas of the building for evidence of significant damage to building materials and finishes as result of moisture intrusion and/or mold/microbial growth.
No evidence of significant problems with moisture intrusion or mold/microbial growth was noted at the Subject Property.
Phase I Environmental Site Assessment -49- C3-10154
7.5 NWI Mapped Wetlands
The National Wetlands Inventory online Wetland Mapper was reviewed for indications of jurisdictional wetlands at or immediately adjoining the Subject Property. The scope of work for this assessment excluded a visual determination of regulated wetlands at the Subject Property.
It is emphasized that, regardless of the data reviewed via the NWI Wetlands Mapper, a field delineation of regulated wetlands by a qualified professional would be warranted to determine the presence or absence of regulated wetlands at the Subject Property.
A review of NWI Wetlands Mapper did not indicate regulated wetland areas on the Property.
7.6 Lead in Drinking Water
The scope of work for this assessment included a review of the potential for elevated levels of lead in drinking water by determining the source of the drinking water supply and a review of available compliance or testing data. Potable water service at the Property is provided by a utility connection with the San Gabriel Valley Water Company.
Phase I Environmental Site Assessment -50- C3-10154
8.0 REFERENCES
ASTM International, “Designation E1527-21 Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process”; ASTM, West Conshohocken, PA, 2021.
ASTM International, “Designation E2600-15-Standard Guide for Vapor Encroachment Screening on Property Involved in Real Estate Transaction”, ASTM, West Conshohocken, PA, 2015.
United States Environmental Protection Agency (USEPA), “EPA Map of Radon Zones by U.S.
County, EPA 402/F19/004”, www.epa.gov/radon/epa-map-radon-zones, 2019 U.S. Fish and Wildlife Service – National Wetlands Inventory, “Wetlands Mapper”, fwsprimary.wim.usgs.gov/wetlands/apps/wetlands-mapper/ 2024 Environmental Data Resources Inc. (EDR), “The EDR Radius Map™ Report with GeoCheck®”, EDR, Sheldon, CT, 2024.
EDR, “The EDR-City Directory Abstract”, EDR, Sheldon, CT, 2024.
EDR, “The EDR Aerial Photo Decade Package”, EDR, Sheldon, CT, 2024.
EDR, “Certified Sanborn Map Report”, EDR, Sheldon, CT, 2024.
EDR, “EDR Historical Topo Map Report with QuadMatch™”, EDR, Sheldon, CT, 2024.
Buonicore A., “Methodology for Identifying the Area of Concern Around a Property Potentially Impacted by Vapor Migration from Nearby Contaminated Sources, Paper 2011-A301-AWMA”, The Buonicore Group, Milford, CT, 2011.
Hydrotech Consultants, Inc., Environmental Property Investigation, Don Julian and Valley Center Properties 15151 Don Julian Road, 525 - 427 Turnbull Canyon Road, 100 - 190 South Sixth Street & 14404-14436 Valley Boulevard, City of Industry, CA, September 27, 1989 Hillmann Consultants LLC, Phase I Environmental Site Assessment, 100-190 South Sixth Avenue, City of Industry, CA, 2023
Hillmann Consultants LLC, Phase I Environmental Site Assessment 14404 -14436 East Valley Boulevard, La Puente, CA, 2023
Hillmann Consultants LLC, Limited Phase II Subsurface Investigation Report, 100-190 S. SIXTH AVE. AND 14404-14436 E. VALLEY BLVD., CITY OF INDUSTRY/ LA PUENTE, CA, 2023 Phase I Environmental Site Assessment -51- C3-10154
APPENDIX A
Site Diagram/Vicinity Map
APPENDIX B
Site Photographs
1. Pad-mounted transformer located on central portion of Subject Property
2. Pole-mounted transformer located along western boundary of Subject Property
3. View of adjoining property to the west of the Subject Property (2)
4. View of adjoining property to the west of the Subject Property
5. View of concrete pad of former building located on eastern portion of Subject Property
6. View of equipment and ink storage within unit 110
SITE PHOTOGRAPHS
100 - 190 South Sixth Avenue, 14404 -14436 East
Valley Boulevard
City of Industry, California
Project No. C3-10154
7. View of equipment storage within Unit 190on Subject
Property
8. View of pad-mounted transformer on southern portion of Subject Property
9. View of former building area on eastern portion of Subject Property
10. View of roll-up garages on southside of Building A
11. View of railroad tracks along adjoining property to the east of the Subject Property
12. View of storage area within unit 101 tenant space
SITE PHOTOGRAPHS
100 - 190 South Sixth Avenue, 14404 -14436 East
Valley Boulevard
City of Industry, California
Project No. C3-10154
13. View of tenant interior space within unit 14434 on Subject Property
14. View of typical bathroom within tenant spaces on Subject Property
15. View of typical front office within buildings on Subject Property
16. Interior view of tenant space on Subject Property
17. Pad-mounted transformer located on central portion of Subject Property
18. Pole-mounted transformer located along western boundary of Subject Property
SITE PHOTOGRAPHS
100 - 190 South Sixth Avenue, 14404 -14436 East
Valley Boulevard
City of Industry, California
Project No. C3-10154
19. View of adjoining property to the west of the Subject Property (2)
20. View of adjoining property to the west of the Subject Property
21. View of concrete pad of former building located on eastern portion of Subject Property
22. View of debris located outside of Units 132-140 on Subject Property
23. View of rooftop of Building B on Subject Property 24. View of hazardous materials chest within Unit 190 2
SITE PHOTOGRAPHS
100 - 190 South Sixth Avenue, 14404 -14436 East
Valley Boulevard
City of Industry, California
Project No. C3-10154
25. View of South Sixth Avenue to the west of the Subject Property
26. View south of former Building D on Subject Property 2
SITE PHOTOGRAPHS
100 - 190 South Sixth Avenue, 14404 -14436 East
Valley Boulevard
City of Industry, California
Project No. C3-10154
APPENDIX C
Questionnaires / User Provided Information
Your Property. Our Priority.
1745 W. Orangewood Avenue, Suite 110, Orange, CA 92868
Telephone (714) 634-9500 Fax: (714) 634-9507 Toll free: (800) 232-4326 www.HillmannConsulting.com
LIMITED PHASE II SUBSURFACE INVESTIGATION REPORT
100-190 S. SIXTH AVE. AND 14404-14436 E. VALLEY BLVD., CITY OF INDUSTRY/ LA PUENTE, CA Prepared For:
CAPROCK ACQUISITIONS III, LLC
1300 Dove Street
Newport Beach, California 92660
Hillmann Project Number C3-9529
June 1, 2023
Written By:
Hillmann Consulting, LLC
Dan Louks
Professional Geologist 4883
Your Property. Our Priority.
1745 W. Orangewood Avenue, Suite 110, Orange, CA 92868
Telephone (714) 634-9500 Fax: (714) 634-9507 Toll free: (800) 232-4326 www.HillmannConsulting.com
June 1, 2023
Mr. Charlie Doherty
Caprock Acquisitions III, LLC
1300 Dove Street
Newport Beach, California 92660
RE: Limited Phase II Subsurface Investigation Report
100-190 S. Sixth Ave. and 14404-14436 East Valley Blvd.
City of Industry/ La Puente, CA
Hillmann Project Number: C3-9529
Dear Mr. Doherty:
Hillmann Consulting, LLC, is pleased to provide this Limited Phase II Subsurface Investigation Report prepared for the above referenced property.
This report is for the exclusive use of the entities named on the front cover, its affiliates, designates and assignees, rating agencies, prospective bond holders and bond holders, and no other party shall have any right to rely on any service provided by Hillmann Consulting, LLC, without prior written consent.
We appreciate the opportunity to provide environmental due diligence services. If you have any questions concerning this report, or if we can assist you in any other matter, please contact the Project Manager at 714-634-9500.
Very Truly Yours,
Hillmann Consulting, LLC
Stephen Bartlett
Senior Project Manager
Hillmann Consulting LLC
Limited Phase II Subsurface Investigation Report i Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA
TABLE OF CONTENTS
1.0 INTRODUCTION / BACKGROUND............................................................................................................1
2.0 GEOLOGY/HYDROGEOLOGY ...................................................................................................................1
3.0 SITE INVESTIGATION.................................................................................................................................1
3.1 Laboratory Results .......................................................................................................................................2
4.0 CONCLUSIONS AND RECOMMENDATIONS ..........................................................................................3
5.0 LIMITATIONS ...............................................................................................................................................3
LIST OF TABLES
TABLE 1 - Summary of Soil Sampling Results
TABLE 1A - Summary of Heavy Metal Sampling Results
TABLE 2 - Summary of Soil Gas Sampling Results
LIST OF FIGURES
FIGURE 1 - Site Vicinity Map
FIGURE 2 - General Site Plan
LIST OF APPENDICES
APPENDIX A - Site Photos
APPENDIX B - Laboratory Reports
APPENDIX C - Drilling Logs
Hillmann Consulting LLC
Limited Phase II Subsurface Investigation Report 1 Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA
1.0 INTRODUCTION / BACKGROUND
Hillmann Consulting, LLC (Hillmann) conducted a Limited Phase II Subsurface Investigation at the commercial property, located at 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA. The property occupies about 6.5 acres located on the southern corner of East Valley Boulevard and South Sixth Avenue in a primarily industrial area of the City of Industry (Figure 1). The property is developed with six (6) industrial buildings built around 1977 and a seventh former industrial building that recently burned and has since been demolished and removed (Bldg. Nos 140 and 148). The layout of the site is depicted on Figure
2. In April 2023, Hillmann conducted a Phase I Environmental Site Assessment at the site and found that the property has been utilized by multiple tenants for various light industrial operations since approximately 1977. Historical occupants included several printing/graphics businesses, which are considered potentially high risk for environmental impacts. Other occupants included light manufacturing operations, machine servicing businesses, warehouse storage, auto painting supplies, and oil supplies. Collectively, the historical light industrial operations were identified as a recognized environmental condition that justified preliminary subsurface investigation. In addition, an adjoining property to the south (14505 Proctor Avenue) formerly managed an above ground storage tank farm that resulted in a known release of VOC to the subsurface. Vapor extraction activities were conducted at that site from 1996 to 2010 and the site was closed with a land use covenant in 2012 by the Los Angeles Regional Water Quality Control Board.
Based on these results, Hillmann conducted a Limited Phase II Subsurface Investigation at the property that included soil and soil gas sampling in targeted locations. The current investigation is an independent assessment of the site that was constrained by time and cost factors as part of a self-directed effort. The investigation included the installation of twenty-one (21) soil borings, twenty (20) of them completed as soil gas sampling probes in targeted areas of the site including suites with a documented history of conducting printing operations. This investigation was not intended to meet the more stringent requirements of a regulatory driven assessment.
2.0 GEOLOGY/HYDROGEOLOGY
During drilling, a California Professional Geologist described the soil using the Unified Soil Classification System. Based on the drilling logs, the sediments beneath the site consist primarily of dense silty sand from near surface to about three feet below grade, underlain by dense silty clay to 6 feet below grade, the maximum depth of exploration. Groundwater was not encountered during drilling to 6 feet below grade and based on data presented on the GeoTracker website, groundwater lies at about 55 feet below grade at a nearby site.
Descriptions of the sediments encountered are presented in the drilling logs (Appendix C).
3.0 SITE INVESTIGATION
On May 11th and May 12th, 2023, Hillmann installed twenty-one (21) soil borings (B1-B21) for a total of twenty (20) soil gas probes in targeted areas of the site identified as formerly or
Hillmann Consulting LLC
Limited Phase II Subsurface Investigation Report 2 Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA currently maintaining suspect operations, including printing and other light industrial use.
These included tenant suites located at 14414, 14420 and 14426 East Valley Boulevard and 110, 122, 126, 132, 138, and 190 South Sixth Avenue. Two (2) of the borings (B19 and B20) were installed at the edge of the footprint of the burned former structure at 140-148 South Sixth Avenue. The borings were installed to total depths ranging from 2.5 to 6 feet below grade using hand auger tools. Each boring (except for B19) was completed as a soil gas sampling probe (SG1-SG21) with sample tips installed at maximum depth. A twentieth soil gas probe (SG21) was installed near the southeast corner of the site nearest to the off-site impacted property that was closed with restrictions. The boring and probe locations are shown on Figure 2. (Note:
there is no probe SG19 and no soil sample from SG21.)
During drilling, a California Professional Geologist described the soil using the Unified Soil Classification System. Soil samples were obtained at select depths in each boring and were preserved for analysis in laboratory glass jars that were sealed with Teflon tape and threaded caps and stored on ice pending delivery to the laboratory. Select samples were analyzed for TPHcc (including full carbon chain analysis through C44) by EPA Method 8015M and heavy metals by EPA Method 6010B. The soil samples were analyzed by A&R Laboratories of Ontario, California. In addition, the soil samples from borings B19 and B20, installed beneath the burned building edge, were tested for Per- and Polyfluoroalkyl Substances (PFAS) by EPA Method 537. These samples were analyzed by Sun Star Laboratories, Inc.
The soil gas sampling probes consist of plastic micro-porous vapor implants that are approximately 2 inches long with a 0.5-inch outside diameter, connected to 0.25-inch outside diameter nylaflow tubing that extended above the surface. The annulus around each vapor implant was backfilled with approximately 1 foot of screen-washed #3 sand. 6 inches of dry bentonite was placed immediately above the sand pack, followed by one-foot of bentonite that was hydrated during placement. The probes were further sealed with hydrated bentonite and neat cement to grade to provide a secure borehole seal. The probes were finished with gas-tight fittings at the surface pending vapor purging and sampling.
The probes were allowed to equilibrate for at least 48 hours before purging and sampling. The probes were sampled using an on-site mobile laboratory service. Prior to vapor sampling, shut-in and leak tests were conducted on the probes.
After purging three (3) volumes through the system, vapor samples were collected from the probes between May 18-23, 2023 by technicians from A&R Laboratories of Ontario, California. The soil gas samples were tested for VOC using EPA Method 8260B by A&R Laboratories of Ontario, California.
3.1 Laboratory Results
Results from soil sampling indicated none of the samples had detectable concentrations of petroleum hydrocarbons or heavy metal concentrations exceeding conservative residential or commercial screening levels. The results from PFAS testing indicated sample B19-1.5 had very low concentrations of some PFAS compounds, none approaching EPA Regional Screening Levels for residential or commercial settings. The soil sampling results are summarized in
Hillmann Consulting LLC
Limited Phase II Subsurface Investigation Report 3 Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA Table 1, and in Table 1A (heavy metals). The laboratory report from soil sampling is included in Appendix B.
Results from soil gas sampling indicated ten (10) of the twenty (20) samples had detectable concentrations of VOC. Five VOC compounds (toluene, ethylbenzene, xylenes, 1,1,1 trichloroethane (1,1,1 TCA), and tetrachloroethene (PCE)), were detected in low concentrations. No other VOC was detected in any of the samples. The detected concentrations were compared to the Regional Screening Levels (RSLs) for soil gas which are based on human health risk factors for residential and commercial settings and are commonly used as screening tools. The screening criteria uses defined indoor air concentrations based on human health risk factors that are modified using the recently adopted attenuation factor provided by DTSC (0.03). Results indicate none of the detected concentrations exceed these conservative commercial screening levels. These results are summarized in Table 2. The laboratory reports from soil gas sampling are included in Appendix B.
4.0 CONCLUSIONS AND RECOMMENDATIONS
The subject site is a light industrial property with multiple buildings constructed in 1977 that are divided into tenant suites, some of which historically conducted printing or other environmentally sensitive operations. In addition, the site lies near a property that was impacted by subsurface VOC contamination which was treated using vapor extraction over a number of years and was ultimately closed with a deed restriction. Based on these results, preliminary subsurface investigation in targeted locations was recommended.
In May 2023, Hillmann conducted an investigation that included the installation of twenty-one (21) shallow soil borings where soil samples were laboratory analyzed, and twenty (20) of these locations were completed as soil gas sampling probes. The twentieth soil gas probe (SG21) was installed along the southern property line to gauge possible impacts from the known off-site contamination. The results from soil sampling indicated no detectable concentrations of petroleum hydrocarbons and no heavy metals concentrations greater than current residential or commercial screening levels. The results from PFAS testing beneath the burned former building indicate many of these compounds were detected, but none at significant concentrations. The results from soil gas sampling indicate very low concentrations of VOC in some samples, none greater than current commercial screening levels.
Based on these results, no additional sampling is recommended for the site.
5.0 LIMITATIONS
This Subsurface Investigation was performed in accordance with generally and currently accepted engineering practices and principles; however, the procedures and methodologies used in this investigation are not intended to meet all specific regulatory guidelines as this work was completed as a self-directed effort. Although the data in this report is indicative of subsurface conditions in areas investigated, no further conclusions regarding the absence or presence of subsurface contamination in other areas of the site should be construed or inferred other than those expressly stated in this report. The conclusions made are based on information
Hillmann Consulting LLC
Limited Phase II Subsurface Investigation Report 4 Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA obtained from field observations, independent laboratory analytical results, and from current and relevant Federal, State, regional, and local agencies.
Limited Phase II Subsurface Investigation Report Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA TABLE 1
Summary of Soil Sampling Results (mg/Kg)
Sample ID Heavy Metals Above
Screening Levels
PFAS
Compounds TPHg C4-C12 TPHd C13-C22 TPH-Oil C23-C40
Sampled May 11-12, 2023
B1-2 None -- ND<0.5 ND<10 ND<20
B2-1.5 -- -- ND<0.5 ND<10 ND<20
B3-1.5 None -- ND<0.5 ND<10 ND<20
B4-1.5 -- -- ND<0.5 ND<10 ND<20
B5-2 None -- ND<0.5 ND<10 ND<20
B6-1.5 -- -- ND<0.5 ND<10 ND<20
B7-1.5 None -- ND<0.5 ND<10 ND<20
B8-1.5 -- -- ND<0.5 ND<10 ND<20
B9-1.5 None -- ND<0.5 ND<10 ND<20
B10-1.5 -- -- ND<0.5 ND<10 ND<20
B11-1.5 -- -- ND<0.5 ND<10 ND<20
B12-1.5 None -- ND<0.5 ND<10 ND<20
B13-1.5 -- -- ND<0.5 ND<10 ND<20
B14-1.5 None -- ND<0.5 ND<10 ND<20
B15-1.5 -- -- ND<0.5 ND<10 ND<20
B16-1.5 None -- ND<0.5 ND<10 ND<20
B17-1.5 -- -- ND<0.5 ND<10 ND<20
B18-1.5 None -- ND<0.5 ND<10 ND<20
B19-1.5 -- Var. ND<0.5 ND<10 ND<20
B20-2 None ND ND<0.5 ND<10 ND<20
Residential RSL -- -- 82 82 82
Commercial RSL -- -- 420 420 420
Notes: ND - Not Detected. EPA Regional Screening Levels (RSLs) are human health risk based screening levels used by EPA and DTSC in residential and commercial settings. The RSL levels for total petroleum hydrocarbons are divided into six non-descript categories that depend on the relative speciation of aromatic and aliphatic hydrocarbons in the source contaminant. The most conservative screening level for petroleum hydrocarbons used. Please refer to lab report for complete results.
Limited Phase II Subsurface Investigation Report Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA TABLE 1A
Summary of Heavy Metal Results (mg/Kg)
Sample ID Arsenic Barium Cadmium Chromium Cobalt Copper Lead Nickel Vanadium Zinc B1-2 4.87 126 1.68 19.3 7.31 39.6 9.34 13.0 29.5 51.4
B3-1.5 2.71 117 1.99 19.3 9.90 51.0 8.50 13.8 36.8 70.6 B5-2 2.87 83.5 1.79 18.0 10.3 57.0 8.77 12.6 37.5 64.5
B7-1.5 4.76 103 1.43 10.7 5.43 30.6 8.28 9.75 25.7 37.3 B9-1.5 3.01 110 1.48 14.2 6.98 39.9 7.01 11.5 25.4 47.1 B12-1.5 2.97 117 1.68 14.0 7.81 41.8 12.5 11.3 28.3 73.3 B14-1.5 2.94 108 1.80 18.7 9.80 55.4 9.78 14.4 34.2 76.2 B16-1.5 2.74 102 1.77 16.4 9.20 50.6 16.3 12.2 33.4 69.8 B18-1.5 4.48 107 2.09 24.2 11.5 63.2 15.2 18.5 42.1 74.3 B20-2 2.36 112 1.43 11.7 6.25 32.8 16.5 10.3 23.1 57.2
Residential RSL 0.11 15,000 7.1* 36,000 23 3,100 80* 490* 390* 23,000 Industrial RSL 0.36 220,000 79* 170,000 350 47,000 500* 3,100* 1,000* 350,000 DTSC Bkgrnd 12 -- -- -- -- -- -- -- -- --
Notes: Some samples also had detectable concentrations of antimony (maximum of 3.72 mg/Kg); Residential RSL=31 mg/Kg; Commercial RSL= 470 mg/Kg beryllium (maximum of 1.64 mg/Kg); Residential RSL= 16 mg/Kg; Commercial RSL= 230 mg/Kg and molybdenum (maximum of 1.22 mg/Kg); Residential RSL= 390 mg/Kg; Commercial RSL= 5,800 mg/Kg. ND - Not Detected. EPA Regional Screening Levels (RSLs) are human health risk based screening levels used by EPA and DTSC in residential and commercial settings. DTSC Background Concentration is based on statistical study of sites throughout southern California. This concentration may be used as a screening level for anthropogenic and naturally occurring levels of arsenic in soil in southern California.* - Values modified by DTSC HERO Note 3. Please refer to lab report for complete results.
TABLE 1B
Summary of PFAS Results (mg/Kg)
Sample ID PFOS PFDA PFDoA PFHpA PFHxA PFNA PFOA PFPeA PFTA PFOSA B19-1.5 0.00076 0.00018 0.00012 0.0001 0.0001 0.000062 0.00057 0.000044 0.000039 0.00014 B20-3 ND ND ND ND ND ND ND ND ND ND
Residential RSL 0.13 -- -- -- 1.3 0.19 0.19 -- -- --
Industrial RSL 1.6 -- -- -- 16 2.5 2.5 -- -- --
Notes: Sample B19-1.5 also had 0.00011 mg/Kg NEtFOSAA and 0.00015 mg/Kg NMeFOSAA. ND - Not Detected. EPA Regional Screening Levels (RSLs) are human health risk based screening levels used by EPA in residential and commercial settings. Please refer to lab report for complete results.
Limited Phase II Subsurface Investigation Report Hillmann Project C3-9529 100-190 S. Sixth Ave. and 14404-14436 E. Valley Blvd., City of Industry/ La Puente, CA TABLE 2
Summary of Soil Gas Sampling Results (ug/L)
Sample ID Benzene Toluene Ethylbenzene Xylenes 1,1,1 TCA TCE PCE Other VOC Sampled May 18-23, 2023
SG1-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG2-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG3-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG4-4 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 0.010 ND SG5-3 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 0.020 ND SG6-3 ND<0.0031 0.010 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG7-1.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG8-2 ND<0.0031 0.040 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG9-2.5 ND<0.0031 0.020 0.010 0.050 ND<0.0065 ND<0.0065 0.030 ND SG10-2.5 ND<0.0031 0.040 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 0.010 ND SG11-2.5 ND<0.0031 0.14 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG12-2.5 ND<0.0031 0.010 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG13-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG14-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG15-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG16-2.5 ND<0.0031 0.010 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG17-2.5 ND<0.024 ND<0.050 ND<0.050 ND<0.10 ND<0.050 ND<0.050 ND<0.050 ND SG18-2.5 ND<0.024 ND<0.050 ND<0.050 ND<0.10 ND<0.050 ND<0.050 ND<0.050 ND SG20-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 ND<0.0065 ND<0.0065 ND<0.0065 ND SG21-2.5 ND<0.0031 ND<0.0065 ND<0.0065 ND<0.013 0.010 ND<0.0065 0.050 ND Commercial
RSL AF=0.03 0.014* 43.3* 0.163 14.67 147* 0.100 0.067* -- Notes: 1,1,1 TCA =1,1,1 trichloroethane. ND - Not Detected. EPA Regional Screening Levels (RSLs) are human health risk based screening levels used by EPA and DTSC to determine Health Risk in residential and commercial settings. *-Values modified for California by DTSC HERO Note 3. Screening levels for soil gas calculated using indoor air values and attenuation factor provided by EPA (0.03) and DTSC (0.001). Please refer to lab report for complete results.
Limited Phase II Subsurface Investigation Report Hillmann Project C3-9529 100-190 S. 6th Ave. and 14404-14436 E. Valley Blvd., City of Industry, CA
FIGURES
FIGURE 1
SITE VICINITY MAP
COMMERCIAL PROPERTY
100-190 South 6th Avenue &
14404-14436 East Valley Boulevard
City of Industry, California
SITE
LEGEND
Soil Borings
Soil Gas Probes
N
S
W E
APPROXIMATE SCALE IN FEET
0 100 200
FIGURE 2
GENERAL SITE PLAN
COMMERCIAL PROPERTY
100-190 South 6th Avenue &
14404-14436 East Valley Boulevard
City of industry, California
EAST VALLEY BOULEVARD
B7/
SG7
SOUTH 6th AVENUE
B8/
SG8
B9/
SG9
B10/
SG10 B1/
SG1
B2/
SG2
B13/
SG13
B14/
SG14
B11/
SG11
B12/
SG12
B15/
SG15
B16/
SG16
B17/
SG17
B18/
SG18
B19
B20/
SG20
B6/
SG6
B5/
SG5
B4/
SG4
B3/
SG3
110 S. 6th Ave.
Spray
Booth
14426 E. Valley
14420 E. Valley
14414 E. Valley
Footprint of Burned
Building
190 S. 6th Ave.
122 S. 6th Ave.
126 S. 6th Ave.
132 S. 6th Ave.
138 S. 6th Ave.
SG21
Limited Phase II Subsurface Investigation Report Hillmann Project C3-9529 100-190 S. 6th Ave. and 14404-14436 E. Valley Blvd., City of Industry, CA
APPENDIX A
Site Photos
SG1 SG2
SG5 SG6
SG7 SG8
SG9 SG10
SG11 SG12
SG13 SG14
SG15 SG16
SG17 SG18
SG20 SG21
Limited Phase II Subsurface Investigation Report Hillmann Project C3-9529 100-190 S. 6th Ave. and 14404-14436 E. Valley Blvd., City of Industry, CA
APPENDIX B
Laboratory Reports
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CASE NARRATIVE
Authorized Signature Name / Title (print) Ken Zheng, President Signature / Date Ken Zheng, President
05/22/2023 14:02:55 Laboratory Job No. (Certificate of Analysis No.) 2305-00113 Project Name / No. INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF
INDUSTRY
Dates Sampled (from/to) 05/11/23 To 05/12/23
Dates Received (from/to) 05/12/23 To 05/12/23
Dates Reported (from/to) 05/19/23 To 5/22/2023
Chains of Custody Received Yes
Comments:
Subcontracting
Organic Analyses
No analyses sub-contracted
Inorganic Analyses
No analyses sub-contracted
Sample Condition(s)
All samples intact
Positive Results (Organic Compounds)
None
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 001 B1-2 Date & Time Sampled: 05/11/23 10:30 @
Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 51 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB Antimony 2.48 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 4.87 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 126 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 0.944 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.68 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 19.3 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 7.31 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 39.6 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 9.34 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum 0.781 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 13.0 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 29.5 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 51.4 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 002 B2-1.5 Date & Time Sampled: 05/11/23 10:50 @ Sample Matrix: Soil
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 002 B2-1.5 Date & Time Sampled: 05/11/23 10:50 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 59 %REC EPA 8015M 50-150 05/15/23 IG
Sample: 003 B3-1.5 Date & Time Sampled: 05/11/23 11:10 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 53 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB Antimony 2.57 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 2.71 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 117 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 1.42 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.99 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 19.3 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 9.90 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 51.0 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 8.50 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum 1.03 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 13.8 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 003 B3-1.5 Date & Time Sampled: 05/11/23 11:10 @ Sample Matrix: Soil
.....continued
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 36.8 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 70.6 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 004 B4-1.5 Date & Time Sampled: 05/11/23 11:30 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 52 %REC EPA 8015M 50-150 05/15/23 IG
Sample: 005 B5-2 Date & Time Sampled: 05/11/23 12:10 @
Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 54 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 005 B5-2 Date & Time Sampled: 05/11/23 12:10 @
Sample Matrix: Soil
.....continued
Antimony 2.93 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 2.87 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 83.5 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 1.41 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.79 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 18.0 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 10.3 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 57.0 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 8.77 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum <0.50 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 12.6 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 37.5 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 64.5 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 006 B6-1.5 Date & Time Sampled: 05/11/23 13:10 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 52 %REC EPA 8015M 50-150 05/15/23 IG
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 007 B7-1.5 Date & Time Sampled: 05/11/23 13:40 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 55 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB Antimony 1.48 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 4.76 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 103 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 0.840 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.43 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 10.7 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 5.43 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 30.6 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 8.28 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum 1.22 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 9.75 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 25.7 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 37.3 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 008 B8-1.5 Date & Time Sampled: 05/11/23 14:20 @ Sample Matrix: Soil
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 008 B8-1.5 Date & Time Sampled: 05/11/23 14:20 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 50 %REC EPA 8015M 50-150 05/15/23 IG
Sample: 009 B9-1.5 Date & Time Sampled: 05/11/23 14:45 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 51 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB Antimony 1.71 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 3.01 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 110 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 0.836 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.48 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 14.2 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 6.98 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 39.9 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 7.01 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum 0.568 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 11.5 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 009 B9-1.5 Date & Time Sampled: 05/11/23 14:45 @ Sample Matrix: Soil
.....continued
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 25.4 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 47.1 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 010 B10-1.5 Date & Time Sampled: 05/11/23 15:30 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/15/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 50 %REC EPA 8015M 50-150 05/15/23 IG
Sample: 011 B11-1.5 Date & Time Sampled: 05/12/23 8:30 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 51 %REC EPA 8015M 50-150 05/15/23 IG
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 012 B12-1.5 Date & Time Sampled: 05/12/23 9:00 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 50 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB Antimony 2.24 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 2.97 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 117 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 1.04 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.68 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 14.0 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 7.81 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 41.8 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 12.5 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum <0.50 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 11.3 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 28.3 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 73.3 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 013 B13-1.5 Date & Time Sampled: 05/12/23 9:30 @ Sample Matrix: Soil
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 013 B13-1.5 Date & Time Sampled: 05/12/23 9:30 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 53 %REC EPA 8015M 50-150 05/15/23 IG
Sample: 014 B14-1.5 Date & Time Sampled: 05/12/23 10:00 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 50 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB Antimony 2.57 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 2.94 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 108 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 1.33 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.80 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 18.7 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 9.80 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 55.4 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 9.78 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum 0.572 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 14.4 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 014 B14-1.5 Date & Time Sampled: 05/12/23 10:00 @ Sample Matrix: Soil
.....continued
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 34.2 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 76.2 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 015 B15-1.5 Date & Time Sampled: 05/12/23 10:30 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 50 %REC EPA 8015M 50-150 05/15/23 IG
Sample: 016 B16-1.5 Date & Time Sampled: 05/12/23 11:00 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 53 %REC EPA 8015M 50-150 05/15/23 IG
[Metals Title 22 no Hg]
Metals Acid Digestion Complete EPA 3050B 1.0 05/18/23 TLB The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research
909-781-6335
1650 S. GROVE AVE., SUITE C
ONTARIO, CA 91761
CHEMISTRY · MICROBIOLOGY · FOOD SAFETY · MOBILE LABORATORIES FOOD · COSMETICS · WATER · SOIL · SOIL VAPOR · WASTES
A & R Laboratories, Inc.
www.arlaboratories.com [email protected]
CERTIFICATE OF ANALYSIS
Date Reported
Date Received
Invoice No.
Cust #
Permit Number
Customer P.O.
98182
G073
2305-00113
Project: INDUSTRIAL PROP. / 14414 E. VALLEY BLVD., CITY OF IND Analysis Result Method Date
05/19/23
05/12/23
Qual Units DF RL Tech
HILLMANN CONSULTING
1745 W. ORANGEWOOD AVE.
STE. #201
ORANGE, CA 92868
Sample: 016 B16-1.5 Date & Time Sampled: 05/12/23 11:00 @ Sample Matrix: Soil
.....continued
Antimony 2.91 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Arsenic 2.74 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Barium 102 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Beryllium 1.22 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cadmium 1.77 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Chromium 16.4 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Cobalt 9.20 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Copper 50.6 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Lead 16.3 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Molybdenum <0.50 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Nickel 12.2 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Selenium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Silver <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Thallium <1.0 mg/Kg EPA 6010B 1.0 1.0 05/18/23 TLB
Vanadium 33.4 mg/Kg EPA 6010B 1.0 0.50 05/18/23 TLB
Zinc 69.8 mg/Kg EPA 6010B 1.0 5.0 05/18/23 TLB
[Mercury]
Mercury Digestion Complete EPA 7471A 1.0 05/16/23 KZ
Mercury <0.042 mg/Kg EPA 7471A 1.0 0.042 05/16/23 KZ
Sample: 017 B17-1.5 Date & Time Sampled: 05/12/23 11:50 @ Sample Matrix: Soil
[TPH Gasoline C4-C12]
Gasoline (C4-C12) <0.50 mg/Kg EPA 8015M 1.0 0.50 05/16/23 IG [Extractable Hydrocarbons]
Extraction Complete EPA 3550B 1.0 05/15/23 IG
C13-C22 <10 mg/Kg EPA 8015M 1.0 10 05/15/23 IG
C23-C40 <20 mg/Kg EPA 8015M 1.0 20 05/15/23 IG
[Surrogate]
Hexacosane 59 %REC EPA 8015M 50-150 05/15/23 IG
The data and information on this, and other accompanying documents, represent only the sample(s) analyzed and is rendered upon condition that it is not to be reproduced, wholly or in part, for advertising or other purposes without approval from the laboratory.
USDA-EPA-NIOSH Testing Food Sanitation Consulting Chemical and Microbiological Analyses and Research