Cities Index.
Agenda

Cudahy City Council
March 3, 2026

Document
Agenda
Meeting
March 3, 2026
Body
Cudahy City Council
Pages
1,692
Original file
223.1 MB
Text extracted from the city's file for reading and search. Open the original on ca-cudahy.civicplus.com. That file is the official record.

FEATURE

PRODUCT
REF. PRODUCT QTY
W009 TOUCH N' GO HARD-WIRED 3
WMM-600 MAINTENANCE MIN. DRAIN 125 GPM FLOW RATE EA 3

ACTIVATOR CONTROL SCHEDULE

FROM (INPUT
CHANNEL) TO # CONDUCTORS
1:01 W009 #1 3 (3/4" CONDUIT)
1:02 W009 #2 3 (3/4" CONDUIT)1:03 W009 #3 3 (3/4" CONDUIT) TYPE
DATE
- -
DWG
NO
SHEET
Water Odyssey™ by Fountain People, Inc. ~ PO Box 807 ~ San Marcos, Texas 78667-0807 Phone (512) 392-1155 ~ Fax (512) 392-1154 ~ www.waterodyssey.com VER. OPT. REV. 04 20 24 W81074 1 A PD 1 2 of 2
PLAN
SALES
PIPE
CUDAHY PARK OPTION 1

PIPING DIAGRAM
SCALE - 3/32"=1'
0 2 4 8
@ 11" x 17"
4850 SQ FT
FEATURE CONTROL SCHEDULE (MANIFOLD #1)
VALVE VALVE SIZE FEATURE REF. FEATURE QTY PIPE SIZE GPM PSI OUTPUT CHANNEL ACTIVATOR V01 1" Std ) $48$63+(5($48$ 63287 1 1" 12 2 2:01 :

V02 1" Std : DUET JET - MINI SERIES 4' THROW 1 1" 6 3 2:02 V03 1 1/2" Std :),$& -JC :),$&-JC 8' HIGH 2 1 1/2" 32 12.5 2:03 W009 #1
V04 1 1/2" Std :),$& -JC :),$&-JC 8' HIGH 2 1 1/2" 32 12.5 2:04V05 1 1/2" Std :),$& -JC :),$&-JC 8' HIGH 2 1 1/2" 32 12.5 2:05V06 1" Std :),$& -CJ :),$&-CJ 8' HIGH 2 1" 17 14 2:06 V07 1" Std :),$& -CJ :),$&-CJ 8' HIGH 2 1" 17 14 2:07V08 1 1/2" Std :& MISSION HILL SHOWER 3 1 1/2" 30 8 2:08 V09 1" Std &


SNOOT SHOOTER 20' THROW 1 1" 18 20 3:01
:

V10 1" Std &


SNOOT SHOOTER 20' THROW 1 1" 18 20 3:02
V11 1" Std ) $48$63+(5( $48$635$<(5 1 1" 15 4 3:03 V12 1" Std : DUET JET - MINI SERIES 4' THROW 1 1" 6 3 3:04 TOTAL FLOW 235
FEATURE CONTROL SCHEDULE (MANIFOLD #2)
VALVE VALVE SIZE FEATURE REF. FEATURE QTY PIPE SIZE GPM PSI OUTPUT CHANNEL ACTIVATOR V13 1" Std & TRIPLE DUMP 1 1" 15 6 3:05 :
V14 1" Std :& WATER WORM 1 HEAD, 2 ARCHES, 1 TAIL 1 1" 15 2-3 3:06 : V15 1 1/2" Std & SPIN FLOWER 1 1 1/2" 30 15 3:07 : V16 1" Std & SPLIT PEA 1 1" 12 3 3:08
:

V17 1" Std &

TRIPLE BIT 6' THROW 1 1" 18 3 4:01
V18 1" Std ) +$/)63+(5( $48$63287 1 1" 5 3 4:02
V19 1 1/2" Std : WATER FLOWER 1' HIGH - 2' SPREAD 2 1 1/2" 20 1 4:03 V20 1" Std : WATER WEB 8' SPREAD 1 1" 16 2 4:04
V21 1" Std ) +$/)63+(5( $48$63287 2 1" 10 3 4:05 V22 1" Std :
 WATER WEAVE 4' HIGH - 8' SPREAD 1 1" 14 2 4:06
V23 1" Std : WATER FLOWER 1' HIGH - 2' SPREA 1 1" 10 1 4:07 V24 1" Std : WATER WICKETS 4 ARCHES 1 1" 15 20 4:08 : 
TOTAL FLOW 180

POWER SUPPLY
120V,1Ø,60HZ
16 AMPS

BY OTHERS
“REFER TO ELECTRICAL

SCHEMATICS AND PROGRAMMING

SHEET FOR WIRING

CONNECTIONS TO BE MADE TO

TAGGED SOLENOID VALVE
ASSEMBLIES”

TO CONTROLLER
DSC-8-32

SEQUENCING

CONTROLLERWALL MOUNTED

DETAIL A
SHOWN AT 4X SCALE
V01 V02 V03 V04 V05 V06 V07 V08 V09 V10 V11 V12 V13 V14 V15 V16 V17 V18 V19 V20 V21 V22 V23 V24

WATER SUPPLY

FROM RECIRC SYSTEM
235 GPM

WATER SUPPLY

FROM RECIRC SYSTEM
180 GPM
MANIFOLD #1
DM-04000
-12-BR-WM
MANIFOLD #2
DM-04000
-12-BR-WM
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1051 of 1214

Page 1081 of 1692 ends

DESCRIPTION INFORMATION
t&/ͲϱϬϬ^ĞƌŝĞƐ/ůůƵŵŝŶĂƚĞĚĞĐŬ:ĞƚŝƐĂ͞ƉŽƵƌͲŝŶͲƉůĂĐĞĂƐƐĞŵďůLJĐŽŶƚĂŝŶŝŶŐĂŇƵƐŚŵŽƵŶƚƐƉƌĂLJĞīĞĐƚ ĂŶĚϯϲϬĚĞŐƌĞĞŝůůƵŵŝŶĂƚŝŶŐůŝŐŚƚĮdžƚƵƌĞ͘dŚĞĂƐƐĞŵďůLJĐĂŶďĞƵƚŝůŝnjĞĚĨŽƌƉůĂnjĂƐƚLJůĞǁĂƚĞƌĨĞĂƚƵƌĞƐŽƌ ŝŶƚĞƌĂĐƚŝǀĞƐƉůĂƐŚƉĂĚƐ͘

PRODUCT SPECIFICATION
t&/ͲϱϬϬ^ĞƌŝĞƐ/ůůƵŵŝŶĂƚĞĚĞĐŬ:Ğƚ͕Ă͟ƉŽƵƌͲŝŶͲƉůĂĐĞ͟ŇƵƐŚŵŽƵŶƚƐƉƌĂLJĞīĞĐƚǁŝƚŚϯϲϬĚĞŐƌĞĞůŝŐŚƚ ĮdžƚƵƌĞ͘dŚĞĂƐƐĞŵďůLJŝŶĐůƵĚĞƐĂƐƚĂŝŶůĞƐƐƐƚĞĞůŚŽƵƐŝŶŐǁŝƚŚĂŶĐŽŵƉůŝĂŶƚϭͬϰ͟ƚŚŝĐŬƐƚĂŝŶůĞƐƐƐƚĞĞů ĚƌĂŝŶĐŽǀĞƌĂŶĚĐŽŶƚĂŝŶƐ;ϭͿŝŶƚĞƌĐŚĂŶŐĞĂďůĞĨŽƵŶƚĂŝŶŶŽnjnjůĞ͖ϯϲϬĚĞŐƌĞĞϮϰs͕ϯϲtĂƚƚ͕> ƌŝŶŐůŝŐŚƚ
ǁŝƚŚĐŽůŽƌĞĚZ'tĚŝŽĚĞƐ͖ŵĂŶƵĂůĂĚũƵƐƚŵĞŶƚǀĂůǀĞ;ƐͿ͖ũƵŶĐƚŝŽŶďŽdž͖ďŽŶĚŝŶŐůƵŐ͖Ϯ͟ŝŶůĞƚĐŽŶŶĞĐƚŝŽŶ͖Ϯ͟ ĚƌĂŝŶĐŽŶŶĞĐƚŝŽŶ͕ĂŶĚϯͬϰ͟ĐŽŶĚƵŝƚĐŽŶŶĞĐƚŝŽŶĨŽƌůŝŐŚƚ͘ƐƐĞŵďůLJŝƐƐŚŝƉƉĞĚǁŝƚŚ;ϯͿĂŶĐŚŽƌďŽůƚƐ͕ ůĞǀĞůŝŶŐŶƵƚƐĂŶĚǁĂƐŚĞƌƐ͘
ϭΖͲϰΗ^Y
ϭΖͲϳΗZ
&
ϲΗ
ϯΗ
ϲΗ
W>Es/
t
^

EK>
KWd/KE^

>Kt
^͘^͘Z/EKs
Z
ϯͬϰΗKEh/d
KEE
d/KE
Z't>

>/',d&/ydhZ

E,KZK>d^͕>
s
>/E'
EhdΘt^,
Z^
;/E>h
Ϳ͕dzW͘;ϯͿ
KEZ
d
&KKd/E'͕
z/E^d>>
Z
^

EKd
ηϮ
ϮΗ/^W>z
/^,Z'
W/W/E'͕
z/E^d>>
Z
;^

EKd
ηϭ

>KtͿ
KE/E'
>h'
&/E/^,

^hZ&
^>KW
ϮйD/E͘
^͘^͘Z/EKs
Z
ϮΗ'Zs/dzZ/E
dKZ
^
ZsK/Z
;
>KtͿ͕z
/E^d>>
Z
ϮΗ/^W>z
/^,Z'
W/W/E'͕
z/E^d>>
Z;^

EKd
ηϭ
>KtͿ
dDW
ZZ
^/^dEd
&^d
E
Z^
ĞƚĂŝůƐ

>
sd/KEs/
t
ϯͬϰΗKEh/d
KEE
d/KE͕
KEh/dz
/E^d>>
Z
ϮΗ'Zs/dzZ/EdK
Z
^
ZsK/Z͕z
/E^d>>
Z
t&/ͲϱϬϬͲ:
:
d>h^d
Z
t&/ͲϱϬϬͲW:͕
:͘WZ
/^/KE:
d
t&/ͲϱϬϬͲ:
ZKtE:
d
t&/ͲϱϬϬͲ^:
^,Kt
Z:
d
EK>
Z
Yh/Z
D
Ed^͗
ϭͿ EŽnjnjůĞ ƌĞƋƵŝƌĞƐ ĮŶĞ ƐĐƌĞĞŶŝŶŐ ĨŽƌ ĚĞďƌŝƐ
ƌĞŵŽǀĂů͘ηϴ;ϯͬϯϮΗͿŵŝŶŝŵƵŵŵĞƐŚŽƌƐŵĂůůĞƌ͘
ϮͿ ,ŽƵƐŝŶŐŵƵƐƚďĞĞŶĐĂƉƐƵůĂƚĞĚŝŶĐŽŶĐƌĞƚĞ
ΎW>Es/
t^K&EK>
^,KtE͘/D
d
ZK&EK>
/^ΕϭͲϯϭͬϯϮΗ
E,KZK>d
d
DW>d
/E>h


Ed
ZK&EK>

:hEd/KEKy
>Kd/KE
d
,E/>Z
Yh/Z
D
Ed^
DK
>η
^WZz,
/',d KZ/&/
^/

;/D
d
ZͿ ϮΖͲϬΗ ϯΖͲϬΗ ϰΖͲϬΗ ϱΖͲϬΗ ϲΖͲϬΗ ϳΖͲϬΗ ϴΖͲϬΗ
t&/ͲϱϬϬͲ:
'WD ϰ͘ϱ ϱ͘Ϭ ϲ͘Ϭ ϲ͘ϱ ϳ͘Ϭ ϴ͘Ϭ ϴ͘ϱ
͘ϭϬϵΗ ,
 ϱ͘ϬΖ ϲ͘ϬΖ ϳ͘ϬΖ ϴ͘ϱΖ ϭϬ͘ϬΖ ϭϮ͘ϬΖ ϭϰ͘ϬΖ
t&/ͲϱϬϬͲW:
'WD ϰ͘Ϭ ϱ͘Ϭ ϲ͘Ϭ ϲ͘ϲ ϳ͘Ϭ ϳ͘ϲ ϴ͘Ϭ
͘ϯϳϱΗ ,
 ϰ͘ϬΖ ϱ͘ϬΖ ϲ͘ϬΖ ϳ͘ϬΖ ϴ͘ϬΖ ϭϬ͘ϬΖ ϭϮ͘ϬΖ
t&/ͲϱϬϬͲ:
'WD ϰ͘ϱ ϱ͘Ϭ ϲ͘Ϭ ϲ͘ϱ ϳ͘Ϭ ϴ͘Ϭ ϴ͘ϱ ͘ϭϬϵΗ
,
 ϱ͘ϬΖ ϲ͘ϬΖ ϳ͘ϬΖ ϴ͘ϱΖ ϭϬ͘ϬΖ ϭϮ͘ϬΖ ϭϰ͘ϬΖ
t&/ͲϱϬϬͲ^:
'WD ϵ͘Ϭ ϭϬ͘ϱ ϭϮ͘Ϭ ϭϯ͘ϱ ϭϰ͘ϱ ϭϲ͘Ϭ ϭϳ͘Ϭ ͘ϭϬϵΗ
,
 ϭϭ͘ϬΖ ϭϮ͘ϬΖ ϭϯ͘ϬΖ ϭϰ͘ϱΖ ϭϲ͘ϬΖ ϭϴ͘ϬΖ ϮϬ͘ϬΖ
:),$&6HULHV,OOXPLQDWHG'HFN-HW
:),$&;;

EKd
^͗
Ͳ ^^
D>zZ
Yh/Z
^KEdZK>WE
>ΘWhDW

>/s
Zz^z^d
D
Ͳ d,ZKdd>/E's>s
Dh^d
Z
DKd
>z>Kd

ϭΖϭͲϭͬϴΗ/D͘
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1052 of 1214 Page 1082 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1053 of 1214 Page 1083 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1054 of 1214 Page 1084 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1055 of 1214 Page 1085 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1056 of 1214 Page 1086 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1057 of 1214 Page 1087 of 1692 )RXQWDLQ3HRSOH,QFa32%R[a+LJKZD\a6DQ0DUFRV7H[DV 3KRQH


a)D[


aZZZZDWHURG\VVH\FRP
)
)LQLVKHG
6XUIDFH


>FP@
$TXD6SKHUH

)XQ)RUPVŒ$TXD6SUD\HU
1RWH

5HIHUWR,QVWDOODWLRQ'HWDLOIRU
DGGLWLRQDOLQVWDOODWLRQSURFHGXUH
6SHFLILFDWLRQV
‘

>‘FP@

 


‘


>‘FP@
0RGHO1XPEHU
)
&RQVWUXFWLRQ
+DUGIRDPFRUHZLWK$TXD$UPRUŒ

VWUXFWXUDOHODVWRPHULFSRO\PHURXWHUVKHOO
DQG
QRQVOLSWH[WXUHGILQLVK
$QFKRUV
(SR[\$QFKRUV%UDVV
6XSSOLHG

)DVWHQHUV
7DPSHUUHVLVWDQWVWDLQOHVV
VWHHO
6XSSOLHG

6SDFH:DVKHUV
$VUHTXLUHG
PXVWEHQRQIHUURXV
%\
,QVWDOOHU

6XSSO\/LQH
ZLWK6FK39&RU%UDVVFRXSOLQJ
FRQQHFWLRQ
%\,QVWDOOHU

+\GUDXOLF5HTXLUHPHQWV
*30
/30
DWSVL

EDU

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1058 of 1214 Page 1088 of 1692 )RXQWDLQ3HRSOH,QFa32%R[a+LJKZD\a6DQ0DUFRV7H[DV 3KRQH


a)D[


aZZZZDWHURG\VVH\FRP
)
)LQLVKHG
6XUIDFH


>FP@
$48$63+(5(Œ


)XQ)RUPVŒ$TXD6SRXW
1RWH

5HIHUWR,QVWDOODWLRQ'HWDLOIRU
DGGLWLRQDOLQVWDOODWLRQSURFHGXUH
6SHFLILFDWLRQV
‘

>‘FP@


>
FP@


‘

>‘FP@
‘

>‘
FP@
0RGHO1XPEHU
)
&RQVWUXFWLRQ
+DUGIRDPFRUHZLWK$TXD$UPRUŒ

VWUXFWXUDOHODVWRPHULFSRO\PHURXWHUVKHOO
DQG
QRQVOLSWH[WXUHGILQLVK
$QFKRUV
(SR[\$QFKRUV%UDVV
6XSSOLHG

)DVWHQHUV
7DPSHUUHVLVWDQWVWDLQOHVV
VWHHO
6XSSOLHG

6SDFH:DVKHUV
$VUHTXLUHG
PXVWEHQRQIHUURXV

%\,QVWDOOHU

6XSSO\/LQH
ZLWK6FK39&RU%UDVVFRXSOLQJ
FRQQHFWLRQ
%\,QVWDOOHU

+\GUDXOLF5HTXLUHPHQWV
*30

/30
DWSVL

EDU

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1059 of 1214 Page 1089 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1060 of 1214 Page 1090 of 1692 %RQGLQJ/XJ
5HPRYDEOH7RS3ODWH )LQLVKHG6XUIDFH
6ORSHWR'UDLQ
)RXQWDLQ3HRSOH,QFa32%R[a+LJKZD\a6DQ0DUFRV7H[DV 3KRQH


a)D[


aZZZZDWHURG\VVH\FRP
+RXVLQJ
0DFKLQHGFDVWEURQ]HZLWKQDWXUDOILQLVK
LQOHWDQGJURXQGLQJOXJ
7RS3ODWH
3ROLVKHGEUDVV
1R]]OH
3UHFLVLRQPDFKLQHGRULILFH
6SHFLILFDWLRQV
)37


>FP@
0LQL6HULHV
:6LPSOH6SUD\ :&6LPSOH6SUD\&RQVHUYLQJ :6LPSOH6SUD\,, :'XR-HW
:3RQ\7DLO

>FP@
',$
:0LVWHHH-HW :'XHW-HW ::DWHU5LEERQ ::DWHU:DQG +\GUDXOLF5HTXLUHPHQWV
WƌŽĚƵĐƚEƵŵďĞƌ ĞƐĐƌŝƉƚŝŽŶ ,ĞŝŐŚƚ dŚƌŽǁ tŝĚƚŚ 'WD W^/ tϭϮϬ hŶĚĞƌǁĂƚĞƌƵďďůĞƌ ϮΖ ϳϱ Ϯ
ϲ ϵϬ ϰ
tϭϮϰ WŽŶLJdĂŝů ϮΖ ϭΖ ϰϮ
ϲΖ ϯΖ ϳ ϲ
tϭϮϱ ^ŝŵƉůĞ^ƉƌĂLJ ϮΖ ϭϮ Ϯ
ϲΖ Ϯϰ ϰ
tϭϮϱ ^ŝŵƉůĞ^ƉƌĂLJŽŶƐĞƌǀŝŶŐ ϮΖ Ϯ͘ϱ Ϯ
ϲΖ ϰ͘ϱ ϰ
tϭϮϲ ^ŝŵƉůĞ^ƉƌĂLJ// ϮΖ Ϯϭ ϭ͘ϱ
ϲΖ ϯϲ ϯ
tϯϯϬ ƵŽ:Ğƚ ϮΖ ϰ Ϯ
ϲΖ ϴϰ
tϯϯϭ DŝƐƚĞĞĞ:Ğƚ ϭ ϮϬ
tϯϰϰƵĞƚ:Ğƚ ϮΖ ϰ Ϯ
ϲΖ ϴϰ
tϯϳϰtĂƚĞƌZŝďďŽŶ ϱΖ ϮΖͲϲΗ ϭϬ Ϯ
tϯϴϬtĂƚĞƌtĂŶĚ ϰΖ ϲϯ
:8QGHUZDWHU%XEEOHU
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1061 of 1214 Page 1091 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1062 of 1214 Page 1092 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1063 of 1214 Page 1093 of 1692 0RGHO1XPEHU
)
&RQVWUXFWLRQ
+DUGIRDPFRUHZLWK$TXD$UPRUŒ

VWUXFWXUDOHODVWRPHULFSRO\PHURXWHUVKHOO
DQG
QRQVOLSWH[WXUHGILQLVK
$QFKRUV
(SR[\$QFKRUV%UDVV
6XSSOLHG

)DVWHQHUV
7DPSHUUHVLVWDQWVWDLQOHVV
VWHHO
6XSSOLHG

6SDFH:DVKHUV
$VUHTXLUHG
PXVWEHQRQIHUURXV

%\,QVWDOOHU

6XSSO\/LQH
ZLWK6FK39&RU%UDVVFRXSOLQJ
FRQQHFWLRQ
%\,QVWDOOHU

+\GUDXOLF5HTXLUHPHQWV
*30

/30
DWSVL

EDU

)RXQWDLQ3HRSOH,QFa32%R[a+LJKZD\a6DQ0DUFRV7H[DV 3KRQH


a)D[


aZZZZDWHURG\VVH\FRP
)
)LQLVKHG
6XUIDFH
‘

>‘FP@

>FP@
+DOI6SKHUH


)XQ)RUPVŒ$TXD6SRXW
1RWH
5HIHUWR,QVWDOODWLRQ'HWDLOIRU
DGGLWLRQDOLQVWDOODWLRQSURFHGXUH
6SHFLILFDWLRQV
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1064 of 1214

Page 1094 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1065 of 1214 Page 1095 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1066 of 1214 Page 1096 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1067 of 1214 Page 1097 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1068 of 1214 Page 1098 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1069 of 1214

Page 1099 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1070 of 1214 Page 1100 of 1692 ϭΖͲϰϳͬϴΗ
'E
E

yy yy yy Ϯ
'
Ͳ
н
'
Ͳ
н
Dy
/EKhd
ϭϯϰϱ
ϭΖͲϮϳͬϴΗ
ϭΖͲϲϳͬϴΗ
ϭΖͲϰϳͬϴΗ

^Z/Wd/KE/E&KZDd/KE͗
&yͲ>
Ͳ>WͲ^ĞƌŝĞƐ >ŝŐŚƚŝŶŐ ŽŶƚƌŽů WĂŶĞů ŝƐĂƐĂ ƐƚĂŶĚ ĂůŽŶĞ ůŝŐŚƚŝŶŐ ĐŽŶƚƌŽů ƐLJƐƚĞŵ ĨŽƌ Ϯϰs͕ Z'ͬZ't ĐŽůŽƌ ĐŚĂŶŐŝŶŐ ůŝŐŚƚ ĨŝdžƚƵƌĞƐ ƚŚĂƚK EKd ŝŶĐůƵĚĞ ŽŶďŽĂƌĚ Dy ĂĚĚƌĞƐƐŝŶŐ͘ dŚĞ ƉĂŶĞů ŝƐ ĚĞƐŝŐŶĞĚ ƚŽ ĂůůŽǁ Ăůů ŽĨ ƚŚĞ ĐŽŶŶĞĐƚĞĚ ĨŝdžƚƵƌĞƐ ƚŽ ĐŚĂŶŐĞ ĞĨĨĞĐƚƐ Ăƚ ƚŚĞ ƐĂŵĞ ƚŝŵĞ ;ŶŽ ŝŶĚŝǀŝĚƵĂů ĨŝdžƚƵƌĞ ĐŽŶƚƌŽůͿ͘ dŚĞ ƚŽƵĐŚ ƉĂŶĞů ůŝŐŚƚŝŶŐ ĐŽŶƚƌŽůůĞƌĂůůŽǁƐ ĨŽƌƉƌŽŐƌĂŵŵĂďůĞĚĂŝůLJŽƉĞƌĂƚŝŽŶƐĐŚĞĚƵůĞƐ ĨŽƌƚŚĞǁĂƚĞƌ ĨĞĂƚƵƌĞŽƌƐƉůĂƐŚƉĂĚůŝŐŚƚŝŶŐĞĨĨĞĐƚƐ͘ dŚĞŽƉƚŝŽŶĂůƉĂŶĞůĐŽŶĨŝŐƵƌĂƚŝŽŶĂůůŽǁƐĨŽƌĐŽŶƚƌŽůůŝŶŐƵƉƚŽ;ϭϬͿŽƌƵƉƚŽ;ϮϬͿĨŝdžƚƵƌĞƐ͘&ŽƌůĂƌŐĞƌůŝŐŚƚŝŶŐĚŝƐƉůĂLJƐ͕ ƉůĞĂƐĞĐŽŶƚĂĐƚ&ŽƵŶƚĂŝŶWĞŽƉůĞĚŝƌĞĐƚůLJĨŽƌĂƐƐŝƐƚĂŶĐĞ͘ WZKhd^W
/&/d/KE͗
&yͲ>
Ͳ>WͲ^ĞƌŝĞƐ͖E
D ϰ ƉŽůLJĐĂƌďŽŶĂƚĞĞŶĐůŽƐƵƌĞ ŝŶĐůƵĚĞƐ͕Dy ϭϬϮϰ ƚŽƵĐŚƐĐƌĞĞŶ ĐŽŶƚƌŽůůĞƌ͕ ƵƉ ƚŽ ƚǁŽ Dy ĚƌŝǀĞƌƐ͕ƵƉƚŽƚǁŽϮϰsƉŽǁĞƌƐƵƉƉůŝĞƐĂŶĚŶĞĐĞƐƐĂƌLJƚĞƌŵŝŶĂůďůŽĐŬƐĨŽƌǁŝƌĞĐŽŶŶĞĐƚŝŽŶƐ͘^LJƐƚĞŵŝƐĐĂƉĂďůĞŽĨ ƵƉƚŽϱϬϬƐĐĞŶĞƐĂŶĚĐŽŶƚƌŽůůŝŶŐĂŵĂdžŝŵƵŵŽĨ;ϭϬͿϯϲǁĂƚƚZ'ͬZ'tĨŝdžƚƵƌĞƐ;&yͲ> Ͳ>WͲϭϬŵŽĚĞůͿŽƌƵƉƚŽ
;ϮϬͿĨŝdžƚƵƌĞƐǁŝƚŚ;&yͲ>
Ͳ>WͲϮϬͿ͘
EKd
^͗
Ͳ ^
WZd
WZK'ZDD/E'^K&dtZ
/E>h
&KZt/EKt^ͬDWZK'ZDD/E'
Ͳ ^DZdW,KE
WW>/d/KEs/>>
&KZZ
DKd
KW
Zd/KE;EZK/ΘŝK^Ϳ
&ŽƵŶƚĂŝŶWĞŽƉůĞ͕/ŶĐ͘
ϰϲϬϬ,ǁLJϭϮϯ
^ĂŶDĂƌĐŽƐ͕dyϳϴϲϲϲh^
d͗;ϱϭϮͿϯϵϮͲϭϭϱϱ
&͗;ϱϭϮͿϯϵϮͲϭϭϱϰ
ǁǁǁ͘ĨŽƵŶƚĂŝŶƉĞŽƉůĞ͘ĐŽŵ
&yͲ>
Ͳ>WͲ^
Z/
^;>/',d/E'KEdZK>WE
>Ϳ
ĞƚĂŝůƐ
DyϭϬϮϰ
dKh,^Z

E
KEdZK>>
Z
WE
>>zKhd;/Ed
ZE>Ϳ WE
>
yd
Z/KZ
E
Dϰ
E>K^hZ

DyZ/s
Z;hWdKϭϬ
>/',d^ͬZ/s
ZͿ ϮϰsWKt
Z^hWW>z;hWdK
ϭϬ&/ydhZ
^ͬ^hWW>zͿ
>WDK
>^
>
d/KE
0RGHO 0D[RI)L[WXUHV 3RZHU5HTXLUHPHQWV
&yͲ>
Ͳ>WͲϭϬ ϭϬ ϭϮϬͬϮϰϬs͕ϱϬͬϲϬŚ͕ϭTͲϭϬ
&yͲ>
Ͳ>WͲϮϬ ϮϬ ϭϮϬͬϮϰϬs͕ϱϬͬϲϬŚ͕ϭTͲϭϱ
^/d
d
,E/>Z
Yh/Z
D
Ed^͗
ϭͿ
ƋƵŝƉŵĞŶƚƐƉĂĐĞŵƵƐƚďĞǀĞŶƚŝůĂƚĞĚĂƐĨŽůůŽǁƐ͗
ĂͿDŝŶŝŵƵŵĂŝƌƚƵƌŶŽǀĞƌƌĂƚĞŽĨϱĐLJĐůĞƐƉĞƌŚŽƵƌ
ďͿŵďŝĞŶƚĂŝƌƚĞŵƉĞƌĂƚƵƌĞŶŽƚƚŽĞdžĐĞĞĚϭϬϰΣ&͘
ϮͿ DĂŝŶƚĂŝŶE
ĐŽŵƉůŝĂŶĐĞǁŚĞŶůŽĐĂƚŝŶŐƉĂŶĞů͘
>Wd
,E/>&
dhZ
^

ŶĐůŽƐƵƌĞ^ƚLJůĞ E
DϰƉŽůLJĐĂƌďŽŶĂƚĞ
dŝŵĞůŽĐŬŽŶƚƌŽů /ŶƚĞŐƌĂůůŽĐŬΘĂůĞŶĚĂƌ
KƵƚƉƵƚWƌŽƚŽĐŽů DyϱϭϮ;yϮͿ
WƌŽŐƌĂŵŵĂďŝůŝƚLJ W͕DĂĐ͕ŶĚƌŽŝĚ͕ŝK^
dŽƵĐŚƐĐƌĞĞŶŽŶŶ͘ h^͕
ƚŚĞƌŶĞƚ͕Z^ϮϯϮ
DĂdžŝŵƵŵηŽĨ^ĐĞŶĞƐ ϱϬϬ
>Wd
,E/>&
dhZ
^
DĞŵŽƌLJ ŵŝĐƌŽ^;ϯϮ'ďDĂdžͿ
DĞŵŽƌLJĂĐŬƵƉ zĞƐ͕>/ZϮϬϯϮ
dĞŵƉĞƌĂƚƵƌĞ ϭϰΣ&ƚŽϭϭϯΣ&
DĂdž͘ηŽĨůŝŐŚƚĨŝdžƚƵƌĞƐ ;ϭϬͿΛϯϲǁĂƚƚƐĞĂĐŚ͕Ϯϰs;&yͲ> Ͳ>WͲϭϬͿ
DĂdž͘ηŽĨůŝŐŚƚĨŝdžƚƵƌĞƐ ;ϮϬͿΛϯϲǁĂƚƚƐĞĂĐŚ͕Ϯϰs;&yͲ> Ͳ>WͲϮϬͿ
ĞƌƚŝĨŝĐĂƚŝŽŶƐ h>>ŝƐƚĞĚ
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1071 of 1214 Page 1101 of 1692 :DWHU+DPPHU$UUHVWRU
3UHVVXUH
*DXJH
'UDLQ
9DOYH
:DOO0RXQW
)UDPHV
[:DOO0RXQW
)UDPHV 8%ROWV
6WDLQOHVV6WHHO
)DVWHQHUV )OXVK
$QFKRUVE\,QVWDOOHU
&ŽƵŶƚĂŝŶWĞŽƉůĞ͕/ŶĐ͕͘WKŽdžϴϬϳ͕ϰϲϬϬ,ŝŐŚǁĂLJϭϮϯ͕^ĂŶDĂƌĐŽƐ͕dĞdžĂƐϳϴϲϲϲ͕h^ WŚŽŶĞ;ϱϭϮͿϯϵϮͲϭϭϱϱ&Ădž;ϱϭϮͿϯϵϮͲϭϭϱϰǁǁǁ͘ĨŽƵŶƚĂŝŶƉĞŽƉůĞ͘ĐŽŵǁǁǁ͘ǁĂƚĞƌŽĚLJƐƐĞLJ͘ĐŽŵǁǁǁ͘ƉůĂLJĐŽƌĞ͘ĐŽŵ '0%5:0
'LD)ODQJHG'LVWULEXWLRQ0DQLIROG:DOO0RXQW
     
7\SLFDO&URVV6HFWLRQ
7\SLFDO(OHYDWLRQ
'0








 
6ROHQRLG9DOYHV

6KRZQ

7KURWWOLQJ9DOYHV

6KRZQ

6ROHQRLG9DOYHV

6KRZQ

7KURWWOLQJ9DOYHV

6KRZQ

    

6ROHQRLG9DOYHV

6KRZQ

7KURWWOLQJ9DOYHV

6KRZQ

,I9DOYHVDUH6SHFLILHG7KH\:LOO%H3RVLWLRQHG,Q
7KH2GG1XPEHU9DOYH3RVLWLRQV2QO\
6ROHQRLG9DOYHV

6KRZQ

7KURWWOLQJ9DOYHV

6KRZQ

:DWHU+DPPHU
$UUHVWRU
39&9DQ6WRQH
)ODQJH,QOHW %ODQNLQJ
)ODQJH
1RWH
7KLVGRFXPHQWLVIRUFRRUGLQDWLRQSXUSRVHVRQO\7KHILQDOQXPEHUDQGVL]HRIWKHYDOYHVZLOOEHVSHFLILHGWRWKHK\GUDXOLFGHVLJQ FULWHULDRIWKHZDWHUIHDWXUHVVHOHFWHG$Q\PDQLIROGRXWOHWVWKDWDUHQRWUHTXLUHGZLOOEHSOXJJHG Cudahy Park Renovation Project, Project # PRE-001 Document Control 1072 of 1214 Page 1102 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1073 of 1214 Page 1103 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1074 of 1214 Page 1104 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1075 of 1214 Page 1105 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1076 of 1214 Page 1106 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1077 of 1214 Page 1107 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1078 of 1214 Page 1108 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1079 of 1214 Page 1109 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1080 of 1214 Page 1110 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1081 of 1214

8.3 OUTDOOR FITNESS

Page 1111 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1082 of 1214

Page 1112 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1083 of 1214 Page 1113 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1084 of 1214 Page 1114 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1085 of 1214 Page 1115 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1086 of 1214 Page 1116 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1087 of 1214 Page 1117 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1088 of 1214

Page 1118 of 1692 ends

Last Updated 4.26.22
Outdoor Fitness General Specifications
PART 1 – GENERAL

1.01 SUMMARY
A. Section includes composite structure, stand-alone fitness stations, fitness courses and accessories.

B. Basis of design is GTFit fitness stations, Thrive composite structures, Challenge Couse fitness courses and accessories as manufactured by GameTime, a PlayCore Company, P.O.

Box 680121, Fort Payne, Alabama 35968-0121, Phone: 1-800-235-2440, www.GameTime.com.

1.02 SUBMITTALS
A. Product Data: Include physical characteristics such as shape, dimensions, gauge and material for each component. Provide finish information and available colors.

B. Shop Drawings: Include plans, elevations, details, and installation instructions for each component.

C. Warranty: Include sample of manufacturer’s standard warranty.

1.03 QUALITY ASSURANCE
A. Installer: Must be certified by the manufacturer.

B. Safety Standards: Comply with requirements of ASTM F 3101-15.

1.04 WARRANTY
A. Warranty shall meet or exceed the warranty provisions of GameTime as follows:

Lifetime limited warranty on all hardware..
10 Year GTfit, THRIVE and Challenge Course stationary posts, welds, and bars. 10 Year limited warranty on integrated GTShade® products. 10 Year limited warranty on fiberglass and DHPL signage. 5 Year limited warranty on GTfit motion posts, welds, and bars against structural failure. 5 Year limited warranty on stainless damper modules, aluminum cycle covers, covered cable nets and components..
3 Year limited warranty on polyurea coated foam & rubber items 2 Year limited warranty on Challenge Course timing components. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1089 of 1214 Page 1119 of 1692 Last Updated 4.26.22
2 Year limited warranty bearings, steel pins, dampers, plastics, rubber parts, cycle pedals and shafts, molded seats, and backrests.
1 Year limited warranty on cycle rib belts and powder coating. 1 Year limited warranty Challenge Course timing components.and all other GameTime products.

PART 2 – PRODUCTS

2.01 MATERIALS
A. Main Structural Uprights

1. Shall be 5” outside diameter tubing, .120”” wall thickness, manufactured to ASTM A-500 Grade B tolerances from cold-formed steel conforming to ASTM A-569 Sheet Spec for steel coil. Minimum yield strength shall be 50,000 psi and minimum tensile strength shall be 55,000 psi. The exterior surface shall be hot dip galvanized; chromate conversions coated, and have a clear high performance organic polymer applied. All upright posts shall be coated with a custom formula TGIC polyester powder coating in conformance with the specification outlined herein.
(AND/OR)

2. Shall be all weld assemblies fabricated from 3"x 5" steel tubing, 1.20” wall thickness purchased 3/16" hot rolled steel plate, and purchased 1/4"hot rolled steel plate. Minimum yield strength shall be 45,000 psi and minimum tensile strength shall be 48,000 psi. The exterior surface is In line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion coated, and a clear high performance organic polymer is applied.

Galvanizing coverage shall demonstrate the ability to exceed 1000 hours salt spray corrosion exposure in accordance with ASTM B-117. Internal surface zinc rich 91% minimum zinc dust content in organic resin, as per ASTM F-1043. All upright posts shall be coated with a custom formula TGIC.
(AND/OR)

3. Shall be 5” outside diameter tubing. .180” wall thickness, manufactured to ASTM A-500 Grade B tolerances from cold-formed steel conforming to ASTM A-569 Sheet Spec for steel coil. Minimum yield strength shall be 50,000 psi and minimum tensile strength shall be 55,000 psi. The exterior surface shall be hot dip galvanized; chromate conversions coated, and have a clear high performance organic polymer applied. All upright posts shall be coated with a custom formula TGIC polyester powder coating in conformance with the specification outlined herein.

B. Component Attachment – Must be factory preset to the uprights to ensure full field compliance with current safety standards. Hinges, or any clamps, that require field locating or field drilling or installation are not acceptable, due to the susceptibility of installation out of compliance with safety standards.

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1090 of 1214 Page 1120 of 1692 Last Updated 4.26.22
C. Plastisol Coated Steel – Products including platforms and steps shall be fabricated from 12 gauge perforated steel with a .08” minimum thickness, textured slip-resistant polyvinyl chloride plastisol dipped coating. Square deck size must be at least 36” x 36” (2,401 square inches), and triangular decks must be equally 36” on all sides (1,250 square inches) and bolt through the uprights. Platforms must attach directly to threaded inserts factory installed to uprights, using (1) 3/8” bolts at each upright connection point to eliminate the possibility of deck slipping. Plastisol coating must be free of latex and tested to meet California standards for Phthalate levels and safe for children.

D. Molded Polyethylene – Products are to be rotationally molded plastic with a ¼” nominal wall thickness. All plastic is to be U.V. stabilized with optional graphics molded into the component during the molding process. Molded products shall have an anti-static additive, and be available in any of the manufacturer’s standard colors.

E. Metal Climbers and Enclosures

1. Shall be fabricated from 1 5/16” OD x .083” (14 gauge) wall galvanized steel tubing with vertical members fabricated of 1 1/16” OD x .075 (15 gauge) wall galvanized steel tubing. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an in line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic overcoating. The interior coating will consist of a special organic acrylic modified polyester.
(AND/OR)

2. Shall be fabricated from 3-1/2" O.D. x .095" (13 gauge) galvanized pipes and 2-3/8" O.D. x .095" (13 gauge) galvanized pipes, and 3/16" Thick H.R. Steel Mounting Plates. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an in line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic overcoating. The interior coating will consist of a special organic acrylic modified polyester.
(AND/OR)

3. Shall be fabricated from 1.66´ O.D.x 0.109´ steel tubing. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an in line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic over-coating. The interior coating will consist of a special organic acrylic modified polyester. (AND/OR)

4. Shall be fabricated from 2" x 2" x .120" (11 Gauge) wall galvanized steel tubing, 1- 5/16" O.D. x .083" (14 Gauge) wall galvanized steel tubing, and 3/16" Thick H.R.

Steel.. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an in line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic over- 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1091 of 1214 Page 1121 of 1692 Last Updated 4.26.22
coating. The interior coating will consist of a special organic acrylic modified polyester.
(AND/OR)

5. Shall be fabricated from 2" x 2" x .120" (11 Gauge) wall galvanized steel tubing, 1- 5/16" O.D. x .083" (14 Gauge) wall galvanized steel tubing,. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an in line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic over-coating. The interior coating will consist of a special organic acrylic modified polyester.

F. Hardware – All nuts, bolts, screws, inserts, and lockwashers used in the assembly of all play equipment shall be stainless steel, yellow dichromate plated steel, blue-coat plated steel, mechanically galvanized or powder coated/yellow dichromate plated steel. All primary fasteners shall be 304 alloy stainless steel. Fasteners with yellow dichromate treatment have an electro-deposited, 99.9% pure zinc substrate applied from a specially formulated solution sealed with a yellow dichromate top coat designed to work in conjunction with the zinc plating. Yellow dichromate has a 320% longer life to white corrosion and 275% longer to red corrosion than does hot-dip galvanizing.

G. Thermoformed Products
All polyethylene shall be an ultra high molecular weight material. All thermoformed molded products shall meet or exceed the following specifications: ASTM D-1248, Type III, Class A, Category 5 and ASTM D-4976 PE235; Density (ASTM D-1505); Melt Flow (ASTM D-1238); Tensile Values (ASTM D-638); Flexural Modulus (ASTM D-790); ESCR Value (ASTM D1693); Vicat Temperature (ASTM D-1525); Brittleness Temperature (ASTM D-746). Complies with FDA Regulation 21 CFR 177.1520. Complies with FMVSS #302 @ >.060".

2.02 REQUIRED COMPONENTS
A. In addition to the requirements contained in this section, refer to layout drawings and schedules of components and accessories on drawings.

B. All components, accessories, hardware, and other items required for a complete and usable system shall be provided.

A.03 FINISHES
A. Coated Parts

1. Shall be coated with polyester coating uniformly applied by the electrostatic method to a minimum thickness of four mils. Promptly after application of the powder, the coating shall be oven-cured at 400 degrees Fahrenheit. The color(s) of the polyester coating shall be as selected by the Architect from the manufacturer’s standard and/or custom color selection charts.
(AND/OR)

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1092 of 1214 Page 1122 of 1692 Last Updated 4.26.22

2. Shall be coated with a 1 lb Polyurea Spray (BC648B-Black), 1lb Polyurea Spray (Playspray 274 A).

GameTime uses an epoxy primer specifically engineered for encapsulating and penetrating cracks, crevices and voids in materials. We cover 100% of exposed metal components with a minimum of 3 mils of epoxy primer. Primed metal components are semi-cured before applying a three to five mil top coat of Super Durable powder paint - the industry's highest grade of powder available without custom formulation. Our Super Durable paint and epoxy primer is tested to 4000+ hours with
minimum creep, gloss loss, color change. This far exceeds the industry standard of 1000 hours of corrosion testing.

B. Galvanized Finish – All components shall have a galvanized finish prior to powder coating and all welds shall be protectively coated with ZRP, a zinc primer that forms a rust-resistant barrier layer over each weld. All galvanized surfaces shall be free of burs, splinters, and sharp edges.

PART 3 – EXECUTION

3.01 INSTALLATION
A. General – Comply with manufacturer’s written installation instructions.

B. Uprights – Set posts in concrete footings. Protect finish during installation. Comply with locations, height, and plumb requirements.

3.02 FIELD QUALITY CONTROL
A. Installation shall be performed by factory certified technicians with at least 3 years experience installing playground equipment

3.03 COMPLETION
A. Protect installed products until completion of project.

B. Touch up, repair, or replace damaged products before substantial completion.

C. Installer shall turn over all installation instructions, parts lists, maintenance instructions, tool kits, and spare materials to the owner upon completion. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1093 of 1214 Page 1123 of 1692 ,QGLYLGXDO3URGXFW6SHFLILFDWLRQV
$GYDQFHG6HULHV


±%DODQFH3ODQN6WDWLRQ
JDXJHJDOYDQL]HGVWHHO
2'[ZDOOJDOYDQL]HGVWHHOSLSH
+'3(
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU 
,±5HFXPEHQW&\FOH
2'[2'[2'[2'[DQG 2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
DQGJDXJHWKLFN+5VWHHO
[UHFWDQJXODUWXELQJ
,QMHFWLRQPROGHG1\ORQ
&ROGUROOHGVWHHO
&RDWHG$&DVW$OXPLQXP
,QMHFWLRQPROGHGSRO\HWK\OHQH
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU ,QFOXVLYH

,±/DWHUDO3XOO'RZQ$FFHVVLEOH
´[´´2'[´´2'[´2'[DQG´2'[´ JDOYDQL]HGVWHHOSLSH
´[
´´[´DQGWKLFNKRWUROOHGVWHHO ´2'´;
´DQG´2'´VWDLQOHVVVWHHO
,QMHFWLRQPROGHG1\ORQ:
$OXPLQXP
,QMHFWLRQPROGHGKLJKGHQVLW\3RO\HWK\OHQH
5XEEHUHQFDSVXODWHGE\FDVWVWHHO
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU 7KULYH


±7+5,9(2XWGRRU*\P
[[[[´2'[´2'[ ´2'[

2'[2'[[[DQG[[ZDOOJDOYDQL]HGWXELQJ 2'IRUPHGVWHHOVSKHUH
DQGKRWUROOHGVWHHO
VWHHOSODWH
WH[WXUHG+'3(
3RO\XUHDVSUD\
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1094 of 1214 Page 1124 of 1692 Freestanding Play Events
Freestanding play equipment and accessories as manufactured by GameTime, a PlayCore Company, P.O. Box 680121, Fort Payne, Alabama 35968-0121, Phone: 1-800-235-2440, www.GameTime.com, shall adhere to the following specifications:

A. Molded Polyethylene – Products are to be rotationally molded plastic with a ¼” nominal wall thickness. All plastic is to be U.V. stabilized with optional graphics molded into the component during the molding process. Molded products shall have an anti-static additive and be available in any of the manufacturer’s standard colors.

B. High Density Polyethylene shall be made from either ½” or 3/4" thick (depending on application used) high density, UV-stabilized and color impregnated polyethylene.

C. Cables - shall be 18mm polyester twisted type with the following properties: calculated tensile strength of >60kN, quantity 6 strands 2.8mm diameter each, steel strands shall have QTY 19 steel wires diameter .62mm each, quantity 3 fiber core 2.7mm diameter each, UV protected polyester impregnated. Terminations shall be made of the following materials: Aluminum forks, stainless steel D-shackles, stainless steel lifting eye nuts. Connections shall be made of the following: Aluminum connector eggs, aluminum 2-piece T-joints, aluminum T-joints, aluminum in-line connector, aluminum ferrules.

D. Hardware – All nuts, bolts, screws, inserts, and lock washers used in the assembly of all play equipment shall be stainless steel, yellow dichromate plated steel, blue-coat plated steel, mechanically galvanized or powder coated/yellow dichromate plated steel. All primary fasteners shall be 304 alloy stainless steel. Fasteners with yellow dichromate treatment have an electro-deposited, 99.9% pure zinc substrate applied from a specially formulated solution sealed with a yellow dichromate topcoat designed to work in conjunction with the zinc plating.

Yellow dichromate has a 320% longer life to white corrosion and 275% longer to red corrosion than does hot-dip galvanizing. PowerScape Plus stainless-steel fasteners shall be button pinin head, socket cap screws with a two-part epoxy locking patch added to the threads. The twopart locking patch shall consist of one part resin and one part catalyst which are activated during installation. After curing, the material shall require a minimum of five times the installation torque to remove the fastener. Manufacturer shall provide special installation tools for pinned fasteners.

FINISHES
A. Polyester (Powder) Coating – The polyester coating shall be uniformly applied by the electrostatic method to a minimum thickness of four mils. Promptly after application of the powder, the coating shall be oven-cured at 350 degrees Fahrenheit. The color(s) of the polyester coating shall be as selected by the Architect from the manufacturer’s standard and/or custom color selection charts. The paint process must adhere to the Powder Coat Institute 4000 Certification.

B. Galvanized Finish – All components shall have a galvanized finish prior to powder coating and shall be protectively coated with ZRP, a zinc primer that forms a rust-resistant barrier layer.

All galvanized surfaces shall be free of burs, splinters, and sharp edges. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1095 of 1214 Page 1125 of 1692 ,QGLYLGXDO3URGXFW6SHFLILFDWLRQV
$WWDFKPHQWV


±&DWDOLQD&OLPEHU%DVH
/LQHDUORZGHQVLW\SRO\HWK\OHQH
2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ DQGWKLFNKRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ %DODQFLQJ

±3RG
2'[
DQG
2'[
JDOYDQL]HGVWHHOWXELQJ

KRWUROOHGVWHHO
/LQHDUORZGHQVLW\SRO\HWK\OHQH
89VWDELOL]HGFRORU
$QWLVWDWLFFRPSRXQGDGGLWLYH
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDSRZGHUFRDWILQLVK
±3RG
2'[
DQG
2'[
JDOYDQL]HGVWHHOWXELQJ

KRWUROOHGVWHHO
/LQHDUORZGHQVLW\SRO\HWK\OHQH
89VWDELOL]HGFRORU
$QWLVWDWLFFRPSRXQGDGGLWLYH
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDSRZGHUFRDWILQLVK
0RWLRQ

±:KLUOZLQG6HDW
6&+JDOYDQL]HGVWHHOSLSH
/LQHDUORZGHQVLW\PDWHULDO
89VWDELOL]HGFRORU
$QWLVWDWLFFRPSRXQGDGGLWLYH
KRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 3DQHOV

±&RPPXQLFDWLRQ3DQHO
WKLFNGLJLWDOKLJKSUHVVXUHODPLQDWH
´2'[
´DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ GLHFDVWDOXPLQXPDOOR\
$OOZHOGDVVHPEO\

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1096 of 1214 Page 1126 of 1692 &RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU 6LJQV


±1'6)LWQHVV6LJQ3DFNDJH
2'[
ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKRWUROOHGVWHHO
WKLFNH[WHULRU'+3/
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 
±1'63OD\2Q6LJQ3DFNDJH
2'[
ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKRWUROOHGVWHHO
WKLFNH[WHULRU'+3/
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ ±:HOFRPH6LJQ


2'[
ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKRWUROOHGVWHHO
WKLFNH[WHULRU'+3/
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 
±:HOFRPH6LJQ


2'[
ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKRWUROOHGVWHHO
WKLFNH[WHULRU'+3/
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 6ZLQJV


±%HOW6ZLQJ6HDW3NJ
GLDPHWHUVWHHOZLUH
ZHOGHGOLQNFRLOFKDLQ
WKLFNFRORULPSUHJQDWHGSRO\YLQ\OFRDWLQJ
89LQKLELWRUV

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1097 of 1214 Page 1127 of 1692 Last Updated 3.8.2022
Powerscape Playground System
PART 1 – GENERAL

1.01 SUMMARY
A. Section includes composite structure, stand-alone play events and accessories.

B. Basis of design is PowerScape® modular play structures, free-standing play equipment and accessories as manufactured by GameTime, a PlayCore Company, P.O. Box 680121, Fort Payne, Alabama 35968-0121, Phone: 1-800-235-2440, www.GameTime.com.

1.02 SUBMITTALS
A. Product Data: Include physical characteristics such as shape, dimensions, gauge and material for each component. Provide finish information and available colors.

B. Shop Drawings: Include plans, elevations, details, and installation instructions for each component.

C. Warranty: Include sample of manufacturer’s standard warranty.

1.03 QUALITY ASSURANCE
A. Manufacturer Qualifications: Equipment components shall be certified by IPEMA’s third party product certification service. Equipment and structural components shall bear the IPEMA certification seal. IPEMA validation is available at www.ipema.org.

B. Installer: Must be certified by the manufacturer.

C. Safety Standards: Comply with requirements of ASTM F 1487.

1.04 WARRANTY
A. Warranty shall meet or exceed the warranty provisions of GameTime as follows:

Lifetime limited warranty on PowerScape®, PrimeTime®, Modern City®, Xscape® & IONiX® uprights.

Lifetime limited warranty on Tru-Loc® connections and upright bolt-through connections.

Lifetime limited warranty on all hardware.
20 Year limited warranty on Timber Décor™ & Timbers recycled plastic lumber. 15 Year limited warranty on metal decks, pipes, rungs, rails, loops, braces, and footbucks. 15 Year limited warranty on rotationally molded products. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1098 of 1214 Page 1128 of 1692 Last Updated 3.8.2022
15-Year limited warranty on VistaRope nylon bearings and ring junction pieces. 10 Year limited warranty on GTFit, THRIVE and Challenge Course posts & bars. 10 Year limited warranty on site furnishings against structural failure. 10-Year limited warranty on SunBlox® products.
10 Year limited warranty on integrated GTShade® products. 10 Year limited warranty on fiberglass and DHPL signage. 10-Year limited warranty on VistaRope WeaveTech cables. 5 Year limited warranty on TuffForms® structures, including TuffCrete™ and PolyShield. 5 Year limited warranty on nylon covered cable net climbers and components. 5 Year limited warranty on GT Symphony Freenotes™ Harmony Park components. 5 Year limited warranty on Super Seats™.
5-Year limited warranty on premature wear of VistaRope cables. 3 Year limited warranty on Everybody Plays polyurea coated foam & rubber strips. 3 Year limited warranty on SaddleMates® rubber and “C” springs. 3-Year limited warranty on SureGrip Material
2 Year limited warranty on Challenge Course timing components. 1 Year limited warranty on all other GameTime products.

PART 2 – PRODUCTS

2.01 MATERIALS
A. Main Structural Uprights

1. Shall be 5” outside diameter tubing, 1/8” wall thickness, extruded from 6005A-T61 aluminum alloy conforming to ASTM-B-221. Minimum yield strength shall be 35,000 psi and minimum tensile strength shall be 38,000 psi. All upright posts shall be coated with a custom formula TGIC polyester powder coating in conformance with the specification outlined herein.
(AND/OR)

2. Shall be 5” outside diameter, 11 gauge (nominal .120”) galvanized round tubing, manufactured to ASTM A-1011 Grade B tolerances from cold-formed steel conforming to ASTM A-569 Sheet Spec for steel coil. Minimum yield strength shall be 45,000 psi and 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1099 of 1214 Page 1129 of 1692 Last Updated 3.8.2022
minimum tensile strength shall be 48,000 psi. The exterior surface is In line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion coated, and a clear high performance organic polymer is applied. Galvanizing coverage shall demonstrate the ability to exceed 1000 hours salt spray corrosion exposure in accordance with ASTM B-117. Internal surface zinc rich 91% minimum zinc dust content in organic resin, as per ASTM F-1043. All upright posts shall be coated with a custom formula TGIC.

B. Tru Loc Connectors – Must attach directly to factory preset threaded insert in the uprights to ensure full field compliance with current safety standards. Hinged, or any clamps, that require field locating or field drilling or installation are not acceptable, due to the susceptibility of installation out of compliance with safety standards.

C. Plastisol Coated Steel – Products including decks, platforms, steps, and bridges shall be fabricated from 11-gauge perforated steel with a .08” minimum thickness, textured slipresistant polyvinyl chloride plastisol dipped coating. Square deck size must be at least 49” x 49” (2,401 square inches), and triangular decks must be equally 49” on all sides (1,040 square inches) and bolt through the uprights. Decks must attach directly to threaded inserts factory installed to uprights, using (2) 3/8” bolts at each upright connection point to eliminate the possibility of deck slipping. Plastisol coating must be free of latex and tested to meet California standards for phthalate levels and safe for children.

D. Molded Polyethylene – Products are to be rotationally molded plastic with a ¼” nominal wall thickness. All plastic is to be U.V. stabilized with optional graphics molded into the component during the molding process. Molded products shall have an anti-static additive and be available in any of the manufacturer’s standard colors.

E. High Density Polyethylene shall be made from either ½” or 3/4" thick (depending on application used) high density, UV-stabilized and color impregnated polyethylene.

F. Metal Climbers and Enclosures – Products shall be fabricated from 1 5/16” OD x .083” (14 gauge) wall galvanized steel tubing with vertical members fabricated of 1 1/16” OD x .075 (15 gauge) wall galvanized steel tubing. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an In-line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic overcoating. The interior coating will consist of a special organic acrylic modified polyester.

G. Cables - shall be 18mm polyester twisted type with the following properties: calculated tensile strength of >60kN, quantity 6 strands 2.8mm diameter each, steel strands shall have QTY 19 steel wires diameter .62mm each, quantity 3 fiber core 2.7mm diameter each, UV protected polyester impregnated. Terminations shall be made of the following materials: Aluminum forks, stainless steel D-shackles, stainless steel lifting eye nuts. Connections shall be made of the following: Aluminum connector eggs, aluminum 2-piece T-joints, aluminum T-joints, aluminum in-line connector, aluminum ferrules.

H. Hardware – All nuts, bolts, screws, inserts, and lock washers used in the assembly of all play equipment shall be stainless steel, yellow dichromate plated steel, blue-coat plated steel, mechanically galvanized or powder coated/yellow dichromate plated steel. All primary fasteners shall be 304 alloy stainless steel. Fasteners with yellow dichromate treatment have 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1100 of 1214 Page 1130 of 1692 Last Updated 3.8.2022
an electro-deposited, 99.9% pure zinc substrate applied from a specially formulated solution sealed with a yellow dichromate topcoat designed to work in conjunction with the zinc plating.

Yellow dichromate has a 320% longer life to white corrosion and 275% longer to red corrosion than does hot-dip galvanizing. PowerScape Plus stainless-steel fasteners shall be button pin-in head, socket cap screws with a two-part epoxy locking patch added to the threads. The two-part locking patch shall consist of one part resin and one part catalyst which are activated during installation. After curing, the material shall require a minimum of five times the installation torque to remove the fastener. Manufacturer shall provide special installation tools for pinned fasteners.

2.02 REQUIRED COMPONENTS
A. In addition to the requirements contained in this section, refer to layout drawings and schedules of components and accessories on drawings.

B. All components, accessories, hardware, and other items required for a complete and usable system shall be provided.

2.03 FINISHES
A. Polyester (Powder) Coating – The polyester coating shall be uniformly applied by the electrostatic method to a minimum thickness of four mils. Promptly after application of the powder, the coating shall be oven-cured at 350 degrees Fahrenheit. The color(s) of the polyester coating shall be as selected by the Architect from the manufacturer’s standard and/or custom color selection charts. The paint process must adhere to the Powder Coat Institute 4000 Certification.

B. Galvanized Finish – All components shall have a galvanized finish prior to powder coating and shall be protectively coated with ZRP, a zinc primer that forms a rust-resistant barrier layer.

All galvanized surfaces shall be free of burs, splinters, and sharp edges.

PART 3 – EXECUTION

3.01 INSTALLATION
A. General – Comply with manufacturer’s written installation instructions.

B. Uprights – Set posts in concrete footings. Protect finish during installation. Comply with locations, height, and plumb requirements.

3.02 FIELD QUALITY CONTROL
A. Installation shall be performed by factory certified technicians with at least 3 years experience installing playground equipment

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1101 of 1214 Page 1131 of 1692 Last Updated 3.8.2022

3.03 COMPLETION
A. Protect installed products until completion of project.

B. Touch up, repair, or replace damaged products before substantial completion.

C. Installer shall turn over all installation instructions, parts lists, maintenance instructions, tool kits, and spare materials to the owner upon completion. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1102 of 1214 Page 1132 of 1692 ,QGLYLGXDO3URGXFW6SHFLILFDWLRQV
$FFHVV&RPSRQHQWV

±&OLPEHU$UFKZD\Z6RFNHW %DUULHU
2'[2'[DQG2'[ZDOOJDOYDQL]HGVWHHO WXELQJ
DQGKRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ


±(QWU\ZD\%DUULHU
2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ +RW5ROOHG0RXQWLQJ7DE
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±(QWU\ZD\*XDUGUDLO
2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
KRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±&OLPEHU2IIVHW(QWU\ZD\
%DUULHU

2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ KRWUROOHG]LQF
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±0RGHUQ7UDQVIHU3ODWIRUPZ*XDUGUDLO
2'[2'[DQG´2'[ ´ZDOOJDOYDQL]HGVWHHO
WXELQJ
DQG
WKLFNKRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJDQGDRYHQ FXUHGPDWWHILQLVKSRO\YLQ\OFKORULGH
39&
FRDWLQJ

±0RGHUQ7UDQVIHU3ODWIRUPZ%DUULHU
2'[2'[DQG´2'[ ´ZDOOJDOYDQL]HGVWHHO
WXELQJ
DQG
WKLFNKRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJDQGDRYHQ FXUHGPDWWHILQLVK39&FRDWLQJ
$WWDFKPHQWV



±0D]H:KHHO
,QMHFWLRQPROGHGIURPFRORULPSUHJQDWHG3RO\SURS\OHQH3RO\FDUERQDWHFRORULPSUHJQDWHG $%6SODVWLFRU$%6SODVWLFZLWKDPLUURUILQLVKDSSOLHG 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1103 of 1214 Page 1133 of 1692 
±6LQJOH*L]PR3DQHO
2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
VWDLQOHVVVWHHO
WKLFNFRORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH $OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ ±6KRUL]/RRS/DG/LQN

2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ $OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ ±6N\ZKHHO$WWDFKPHQW
2'[
2'[DQG2'[ZDOOJDOYDQL]HGVWHHO WXELQJ
KRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ ±7KXQGHU5LQJ
FRORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ ±&UXQFK%DU
2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 
±&UXQFK%DU
2'[
JDXJH
ZDOOJDOYDQL]HGVWHHOWXELQJ
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 

±%RQJRV
FRORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH

±6FKRRQHU&OLPEHU
2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ WKLFNVWDLQOHVVVWHHO
$OOZHOGFRQVWUXFWLRQ
&RDWHGZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±/HDQLQJ:DOO&OLPEHU

2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFN
VROLG
KLJKGHQVLW\89VWDELOL]HGODPLQDWHGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH &RDWHGZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±&ORYHU/HDI&OLPEHU
2'[2'[DQG
[ZDOOJDOYDQL]HGVWHHOWXELQJ
KRWUROOHGVWHHO
/DVHUFXW
&RDWHGZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU


±5LYHU5RFN&OLPEHU

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1104 of 1214 Page 1134 of 1692 2';ZDOOJDOYDQL]HGVWHHOWXELQJ
[KRWUROOHGVWHHO
5RFNIRUPDWLRQVDQGQDWXUDOURFNVKDSHGKDQGKROGV
$GGLWLRQDOSOD\DFWLYLW\
/LQHDUORZGHQVLW\SRO\HWK\OHQH
&RDWHGZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ


±+RXU*ODVV&OLPEHU
2'[DQG2'[
JDXJH
ZDOOJDOYDQL]HGVWHHOWXELQJ
KRWUROOHGVWHHO
$OOZHOGFRQVWUXFWLRQ
&RDWHGZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±(UJR&OLPEHU
2'[
2'[2'[DQG2' ZDOO
JDOYDQL]HGVWHHOWXELQJ
[KRWUROOHGVWHHOSODWH
2QHSLHFHZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±7KH6SOLWWHU
2'[´2'[´DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ ´DQG´KRWUROOHGIODWVWHHO
WKLFN
VROLG
KLJKGHQVLW\89VWDELOL]HGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH &RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ


±'RXEOH%XEEOH&OLPEHU


[ZDOOJDOYDQL]HGVWHHOSLSH
KRWUROOHGVWHHO
*DXJHJDOYDQL]HGVWHHO
2QHSLHFHZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHU



±2O\PSXV&OLPEHU$WWDFKPHQW
2XWVLGH'LDPHWHU[´DQG2'[JDOYDQL]HGURXQGWXELQJ DQGWKLFNKRWUROOHGVWHHO
WKLFN
VROLG
KLJKGHQVLW\89VWDELOL]HGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH &ROGIRUPHGVWHHO
+RWGLSJDOYDQL]HG
&KURPDWHFRQYHUVLRQFRDWHG
&OHDUKLJKSHUIRUPDQFHRUJDQLFSRO\PHU
PLQLPXP]LQFULFKSULPHU
6WDLQOHVVVWHHO\HOORZGLFKURPDWHSODWHGVWHHOEOXHFRDWSODWHGVWHHOPHFKDQLFDOO\ JDOYDQL]HGRUSRZGHUFRDWHG\HOORZGLFKURPDWHSODWHGVWHHO VHULHVVWDLQOHVVVWHHO
(OHFWURGHSRVLWHG


SXUH]LQFVXEVWUDWHDSSOLHGIURPDVSHFLDOO\IRUPXODWHGVROXWLRQ $OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±7ZLVWHG5DLO&OLPEHU
[´2'[2'[2'[DQG´2'[ ´ZDOOJDOYDQL]HGVWHHOWXELQJ

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1105 of 1214 Page 1135 of 1692 WKLFNKRWUROOHGVWHHO
+RWGLSJDOYDQL]HG
&KURPDWHFRQYHUVLRQFRDWHG
&OHDUKLJKSHUIRUPDQFHRUJDQLFSRO\PHU
PLQLPXP]LQFULFKSULPHU
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 'HFNV

±3XQFKHG6WHHO'HFN
[[DQG[KRWUROOHGVWHHO 0LQLPXPVXUIDFHDUHDRI
VTXDUHLQFKHV

FHQWHUWRFHQWHUVSDFLQJRQWKHXSULJKWSRVWV
VXSSRUWJULGXQGHUQHDWKWKHHQWLUHGHFNVXUIDFH
2QHSLHFHZHOGHGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDQRYHQFXUHGPDWWHILQLVKSRO\YLQ\OFKORULGH 39&
FRDWLQJ
'LUHFWO\EROWHGWRWKHXSULJKWSRVWVZLWKVL[GLDPHWHUEXWWRQSLQLQKHDGKH[VRFNHWFDS VFUHZV

±7ZR3LHFH+H['HFN
[DQG[KRWUROOHGVWHHO
0LQLPXPVXUIDFHDUHDRIVTXDUHLQFKHV

FHQWHUWRFHQWHUVSDFLQJRQWKHXSULJKWSRVWV
VXSSRUWJULGXQGHUQHDWKWKHHQWLUHGHFNVXUIDFH
2QHSLHFHZHOGHGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDQRYHQFXUHGPDWWHILQLVKSRO\YLQ\OFKORULGH 39&
FRDWLQJ
'LUHFWO\EROWHGWRWKHXSULJKWSRVWVZLWKWZHOYHGLDPHWHUEXWWRQSLQLQKHDGKH[VRFNHW FDSVFUHZV
/LQNV

±7UDQVIHU6\VWHPZLWK%DUULHU
2'[DQG2'[DQGVTXDUH[ZDOOJDOYDQL]HGVWHHO WXELQJ
JDXJHSXQFKHGVWHHO
0DWWH39&FRDWLQJ
3URWHFWLYH3 2ILQLVK
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±6ORSHG)XQQHO&OLPEHUZ%DUULHU
2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ 3XQFKHGVWHHO
WKLFNKLJKGHQVLW\89VWDELOL]HGODPLQDWHGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH 0DWWH39&FRDWLQJ
JDXJH[DQG[KRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ



±6WDQGDUG)XQQHO%ULGJHZ%DUULHU'HFN

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1106 of 1214 Page 1136 of 1692 2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ JDXJH[DQG[KRWUROOHGVWHHO
3XQFKHGVWHHO
0DWWH39&FRDWLQJ
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ


±$LU:DONHU
´2'[
´2'[
DQG´2'[´ZDOOJDOYDQL]HGVWHHOWXELQJ ´´´DQGKRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ &RDWHGXVLQJDQRYHQIXVHGIXQFWLRQDOL]HGSRO\HWK\OHQHFRSRO\PHUEDVHGWKHUPRSODVWLF FKDLQVWUDLJKWOLQNFRLOJDOYDQL]HGVWHHOFKDLQ PPGLDPHWHU
89SURWHFWHG
3RO\HVWHUWZLVWHGW\SH

±5LSSOH3DVV
´2'[
´DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ ´´DQGKRWUROOHGVWHHO
PPGLDPHWHUSRO\HVWHUWZLVWHGW\SH
89SURWHFWHG
´WKLFNKLJKGHQVLW\89VWDELOL]HGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH $OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 3DQHOV

±)XQ6HDW3DQHO
2'[DQG2'[ZDOOJDOYDQL]HGVWHHOWXELQJ VWDLQOHVVVWHHO
/LQHDUORZGHQVLW\SRO\HWK\OHQH
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±&DODED]R3DQHO
FRORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH
WKLFNKLJKGHQVLW\89VWDELOL]HGODPLQDWHGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH $OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±&RXQWHU3DQHO
2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKLJKGHQVLW\89VWDELOL]HGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH &RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±+DOI3DQHOZ7KXQGHUULQJ
FRORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1107 of 1214 Page 1137 of 1692

±&RORU:KHHO*DGJHW3DQHO
WKLFNKLJKGHQVLW\89VWDELOL]HGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH &RORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH

±)ORZHU6SLQQHU3DQHO
2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKLJKGHQVLW\FRORULPSUHJQDWHGSRO\HWK\OHQH
89VWDELOL]HG
&RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ

±$QLPDO5DFH+DOI3DQHO
2'[ZDOOJDOYDQL]HGVWHHOWXELQJ
WKLFNKLJKGHQVLW\89VWDELOL]HGDQGFRORULPSUHJQDWHGSRO\HWK\OHQH &RDWHGDIWHUIDEULFDWLRQZLWKDFXVWRPIRUPXODRI7*,&SRO\HVWHUSRZGHUFRDWLQJ 6OLGHV

±6LQJOH=LS6OLGH

&RORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH
0LQLPXPZDOOWKLFNQHVV
0LQLPXPLQVLGHEHGZLGWKRI
0LQLPXPUDGLXV
0D[LPXPRIƒ
,QWHJUDWHGGUDLQDWƒ

±=LS6ZHUYH6OLGH5LJKW


&RORULPSUHJQDWHGOLQHDUORZGHQVLW\SRO\HWK\OHQH
0LQLPXPZDOOWKLFNQHVV
0LQLPXPLQVLGHEHGZLGWKRI
0LQLPXPUDGLXV
0D[LPXPRIƒ
,QWHJUDWHGGUDLQDWƒ

±6SLUDO6OLGHZLWK+RRG

´2'[´2'[´2'[ ´DQG2'[ZDOO
JDOYDQL]HGVWHHO
/LQHDUORZGHQVLW\SRO\HWK\OHQH
DQGJDXJHDQGWKLFNKRWUROOHGVWHHO
$OOZHOGDVVHPEO\
&RDWHGDIWHUIDEULFDWLRQZLWKDQRYHQFXUHGPDWWHILQLVKSRO\YLQ\OFKORULGH 39&
FRDWLQJ

JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1108 of 1214 Page 1138 of 1692 Last Updated 3.8.22
PrimeTime Playground System
PART 1 – GENERAL

1.01 SUMMARY
A. Section includes composite structure, stand-alone play events and accessories.

B. Basis of design is PrimeTime® modular play structures, free-standing play equipment and accessories as manufactured by GameTime, a PlayCore Company, P.O. Box 680121, Fort Payne, Alabama 35968-0121, Phone: 1-800-235-2440, www.GameTime.com.

1.02 SUBMITTALS
A. Product Data: Include physical characteristics such as shape, dimensions, gauge and material for each component. Provide finish information and available colors.

B. Shop Drawings: Include plans, elevations, details, and installation instructions for each component.

C. Warranty: Include sample of manufacturer’s standard warranty.

1.03 QUALITY ASSURANCE
A. Manufacturer Qualifications: Equipment components shall be certified by IPEMA’s third party product certification service. Equipment and structural components shall bear the IPEMA certification seal. IPEMA validation is available at www.ipema.org.

B. Installer: Must be certified by the manufacturer.

C. Safety Standards: Comply with requirements of ASTM F 1487.

1.04 WARRANTY
A. Warranty shall meet or exceed the warranty provisions of GameTime as follows:

Lifetime limited warranty on PowerScape®, PrimeTime®, Modern City®, Xscape® & IONiX® uprights.

Lifetime limited warranty on Tru-Loc® connections and upright bolt-through connections.

Lifetime limited warranty on all hardware.
20 Year limited warranty on Timber Décor™ & Timbers recycled plastic lumber. 15 Year limited warranty on metal decks, pipes, rungs, rails, loops, braces, and foot bucks. 15 Year limited warranty on rotationally-molded products. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1109 of 1214 Page 1139 of 1692 Last Updated 3.8.22
15-Year limited warranty on VistaRope nylon bearings and ring junction pieces. 10 Year limited warranty on GTFit, THRIVE and Challenge Course posts & bars. 10 Year limited warranty on site furnishings against structural failure. 10-Year limited warranty on SunBlox® products.
10 Year limited warranty on integrated GTShade® products. 10 Year limited warranty on fiberglass and DHPL signage. 10-Year limited warranty on VistaRope WeaveTech cables. 5 Year limited warranty on TuffForms® structures, including TuffCrete™ and PolyShield. 5 Year limited warranty on nylon covered cable net climbers and components. 5 Year limited warranty on GT Symphony Freenotes™ Harmony Park components. 5 Year limited warranty on Super Seats™.
5-Year limited warranty on premature wear of VistaRope cables. 3 Year limited warranty on Everybody Plays polyurea coated foam & rubber strips. 3 Year limited warranty on SaddleMates® rubber and “C” springs. 3-Year limited warranty on SureGrip Material
2 Year limited warranty on Challenge Course timing components. 1 Year limited warranty on all other GameTime products.

PART 2 – PRODUCTS

2.01 MATERIALS
A. Main Structural Uprights

1. Shall be 3.5” outside diameter tubing, 1/8” wall thickness, extruded from 6005A-T61 aluminum alloy conforming to ASTM-B-221. Minimum yield strength shall be 35,000 psi and minimum tensile strength shall be 38,000 psi. All upright posts shall be coated with a custom formula TGIC polyester powder coating in conformance with the specification outlined herein.
(AND/OR)

2. Shall be 3.5” outside diameter, 13 gauge (nominal .095”) galvanized round tubing, manufactured to ASTM A-500 Grade B tolerances from cold-formed steel conforming to 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1110 of 1214 Page 1140 of 1692 Last Updated 3.8.22
ASTM A-1011 Sheet Spec for steel coil. Minimum yield strength shall be 45,000 psi and minimum tensile strength shall be 48,000 psi. The exterior surface is In line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion coated, and a clear high performance organic polymer is applied. Galvanizing coverage shall demonstrate the ability to exceed 1000 hours salt spray corrosion exposure in accordance with ASTM B-117. Internal surface zinc rich 91% minimum zinc dust content in organic resin, as per ASTM F-1043. All upright posts shall be coated with a custom formula TGIC.

B. Component Attachment – Must be factory preset to the uprights to ensure full field compliance with current safety standards. Hinges, or any clamps, that require field locating or field drilling or installation are not acceptable, due to the susceptibility of installation out of compliance with safety standards.

C. Plastisol Coated Steel – Products including decks, platforms, steps, and bridges shall be fabricated from 12 gauge perforated steel with a .08” minimum thickness, textured slip-resistant polyvinyl chloride plastisol dipped coating. Square deck size must be at least 36” x 36” (1,296 square inches), and triangular decks must be equally 36” on all sides (561 square inches).

Decks must attach directly to threaded inserts factory installed to uprights, using (1) 3/8” bolts at each upright connection point to eliminate the possibility of deck slipping. Plastisol coating must be free of latex and tested to meet California standards for phthalate levels and safe for children.

D. Molded Polyethylene – Products are to be rotationally molded plastic with a ¼” nominal wall thickness. All plastic is to be U.V. stabilized with optional graphics molded into the component during the molding process. Molded products shall have an anti-static additive, and be available in any of the manufacturer’s standard colors.

E. High Density Polyethylene shall be made from either ½” or 3/4" thick (depending on application used) high density, UV-stabilized and color impregnated polyethylene.

F. Metal Climbers and Enclosures – Products shall be fabricated from 1 5/16” OD x .083” (14 gauge) wall galvanized steel tubing with vertical members fabricated of 1 1/16” OD x .075 (15 gauge) wall galvanized steel tubing. All tubing used shall be an electrical resistance welded, cold rolled, high strength steel tubing. The exterior coating will consist of an in line Zinc Flo Coating with a zinc coating of .03 thickness minimum, chromate conversion, and acrylic overcoating. The interior coating will consist of a special organic acrylic modified polyester.

G. Cables - shall be 18mm polyester twisted type with the following properties: calculated tensile strength of >60kN, quantity 6 strands 2.8mm diameter each, steel strands shall have QTY 19 steel wires diameter .62mm each, quantity 3 fiber core 2.7mm diameter each, UV protected polyester impregnated. Terminations shall be made of the following materials: Aluminum forks, stainless steel D-shackles, stainless steel lifting eye nuts. Connections shall be made of the following: Aluminum connector eggs, aluminum 2-piece T-joints, aluminum T-joints, aluminum in-line connector, aluminum ferrules.

H. Hardware – All nuts, bolts, screws, inserts, and lock washers used in the assembly of all play equipment shall be stainless steel, yellow dichromate plated steel, blue-coat plated steel, mechanically galvanized or powder coated/yellow dichromate plated steel. All primary fasteners shall be 304 alloy stainless steel. Fasteners with yellow dichromate treatment have 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1111 of 1214 Page 1141 of 1692 Last Updated 3.8.22
an electro-deposited, 99.9% pure zinc substrate applied from a specially formulated solution sealed with a yellow dichromate top coat designed to work in conjunction with the zinc plating.

Yellow dichromate has a 320% longer life to white corrosion and 275% longer to red corrosion than does hot-dip galvanizing.

2.02 REQUIRED COMPONENTS
A. In addition to the requirements contained in this section, refer to layout drawings and schedules of components and accessories on drawings.

B. All components, accessories, hardware, and other items required for a complete and usable system shall be provided.

2.03 FINISHES
A. Polyester (Powder) Coating – The polyester coating shall be uniformly applied by the electrostatic method to a minimum thickness of four mils. Promptly after application of the powder, the coating shall be oven-cured at 350 degrees Fahrenheit. The color(s) of the polyester coating shall be as selected by the Architect from the manufacturer’s standard and/or custom color selection charts. The paint process must adhere to the Powder Coat Institute 4000 Certification.

B. Galvanized Finish – All components shall have a galvanized finish prior to powder coating and shall be protectively coated with ZRP, a zinc primer that forms a rust-resistant barrier layer. All galvanized surfaces shall be free of burs, splinters, and sharp edges.

PART 3 – EXECUTION

3.01 INSTALLATION
A. General – Comply with manufacturer’s written installation instructions.

B. Uprights – Set posts in concrete footings. Protect finish during installation. Comply with locations, height, and plumb requirements.

3.02 FIELD QUALITY CONTROL
A. Installation shall be performed by factory certified technicians with at least 3 years’ experience installing playground equipment

3.03 COMPLETION
A. Protect installed products until completion of project.

B. Touch up, repair, or replace damaged products before substantial completion.

C. Installer shall turn over all installation instructions, parts lists, maintenance instructions, tool kits, and spare materials to the owner upon completion. 
JDPHWLPHFRP_
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1112 of 1214 Page 1142 of 1692 gametime.com 800.235.2440

WARRANTY
GameTime offers a comprehensive warranty on all of our products.

For the purpose of this warranty, “lifetime” encompasses no specific term of years, but rather that the Seller warrants to its original customer for as long as the original customer owns the product, and uses the product for its intended purpose, that the product and all its parts will be free from defects in material and manufacturing workmanship.
• Lifetime limited warranty on PowerScape®, PrimeTime®, Xscape® & IONiX® and Modern City® uprights. • Lifetime limited warranty on Tru-Loc® connections and upright bolt-through connections. • Lifetime limited warranty on all hardware.
• Twenty-Year limited warranty on Timber Décor & Timbers recycled plastic lumber. • Fifteen-Year limited warranty on metal decks, pipes, rungs, rails, loops, braces, and footbucks. • Fifteen-Year limited warranty on rotationally-molded products. • Fifteen-Year limited warranty on VistaRopeTM nylon bearings and ring junction pieces. • Ten-Year limited warranty on GTFit®, THRIVE® and Challenge Course posts & bars. • Ten-Year limited warranty on site furnishings against structural failure. • Ten-Year limited warranty on SunBlox products.
• Ten-Year limited warranty on fiberglass and DHPL signage. • Ten-Year limited warranty on VistaRopeTM WeaveTechTM cables. • Five-Year limited warranty on Tuff Forms® structures, including TuffCrete and PolyShield. • Five-Year limited warranty on nylon-covered cable net climbers and components. • Five-Year limited warranty on GT Symphony FreenotesTM Harmony Park components. • Five-Year limited warranty on Super Seats.
• Five-Year limited warranty on premature wear of VistaRope cables. • Three-Year limited warranty on EveryBODY Plays® polyurea coated foam & rubber strips. • Three-Year limited warranty on SaddleMates rubber and “C”-springs. • Three-Year limited warranty on rubber seat and rubber mats for net events. • One-Year limited warranty on Challenge Course timing components. • One-Year limited warranty on all other GameTime products.

TO THE EXTENT PERMITTED BY LAW, THESE WARRANTIES ARE EXPRESSLY IN LIEU OF ANY OTHER

IMPLIED OR EXPRESSED WARRANTIES OR REPRESENTATIONS BY ANY PERSON, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS. Warranties do not cover damage caused by vandalism or abuse. Warranty claims must be filed within the applicable warranty period and accompanied by a copy of the original invoice or GameTime invoice number.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1113 of 1214 Page 1143 of 1692

WARRANTY
)UHHQRWHV +DUPRQ\ 3DUN SURYLGHV D OLPLWHG ZDUUDQW\ RQ RXWGRRUPXVLFDO LQVWUXPHQWV 7KHVH ZDUUDQWLHVFRYHUGDPDJHGXHWRIDLOXUHRUFRUURVLRQRIPHWDOSDUNVWKDWFDXVHWKHSURGXFWWR EHFRPHXQILWIRULQWHQGHGXVH7KHZDUUDQW\FRYHUVWKHOLIHRIWKHSURGXFWDVGHILQHGEHORZ DQGFRYHUVWKHSURGXFWXQGHUQRUPDOXVHZLWKSURSHUPDLQWHQDQFHDWWKHRULJLQDOLQVWDOODWLRQ ORFDWLRQ ,QVWUXPHQWV ZDUUDQW\ ZLOO EH YRLGHG LI QRW LQVWDOOHG LQ DFFRUGDQFH ZLWK PDQXIDFWXUHU·VVSHFLILFDWLRQV
/,)(7,0(/,0,7(':$55$17<21)5((127(6
)UHHQRWHV+DUPRQ\ 3DUNSURYLGHVD OLIHWLPH OLPLWHGZDUUDQW\ RQPHWDO XSULJKWSRVWV XVHG LQ VXSSRUWLQJ VWUXFWXUH RI IUDPHV DQG XSULJKWV DJDLQVW VWUXFWXUDO IDLOXUH RU FRUURVLRQ RI PHWDO SDUWVWKDWFDXVHWKHSURGXFWWREHFRPHVWUXFWXUDOO\XQILWIRULWVLQWHQGHGXVH /,)(7,0(/,0,7(':$55$17<21+$5':$5(
)UHHQRWHV +DUPRQ\ 3DUN SURYLGHV D OLIHWLPH OLPLWHG ZDUUDQW\ RQ VWUXFWXUDO IDLOXUH GXH WR EUHDNLQJRU VKHDULQJZKLFKFDXVHG WKHSURGXFW WREHFRPH VWUXFWXUDOO\XQILW IRU LWV LQWHQGHG XVH
 D OLIHWLPH ZDUUDQW\ RQ VWDLQOHVV VWHHO KDUGZDUH DJDLQVW UXVW  DQG D RQH\HDU OLPLWHG
ZDUUDQW\RQKDUGZDUHDJDLQVWUXVW
VHHH[FOXVLRQV
),9(<($5/,0,7(':$55$17<21+'3($1'//'3(&20321(176 +'3(FRPSRQHQWVVXFKDVUHF\FOHGSODVWLFSRVWVRULQVWUXPHQWIUDPHZRUNDUHFRYHUHGXQGHU QRUPDODSSOLFDWLRQVDJDLQVWVSOLQWHULQJGHFD\RUIDGLQJWKDWFDXVHVWKHSURGXFWWREHFRPH LQDGHTXDWH
),9(<($5/,0,7(':$55$17<21$/80,180&20321(176
$OXPLQXP SDUWV OLNH EDUV UHVRQDWRUV DQG FKLPHV DUH FRYHUHG LI WKHUH LV D GHILFLHQF\ WKDW FDXVHV WKH SURGXFW WR EHFRPH VWUXFWXUDOO\ XQILW IRU WKH LQWHQGHG XVH RU DIIHFWV WKH WRQDO TXDOLW\RIWKHLQVWUXPHQW
),9(<($5/,0,7(':$55$17<2132:'(5&2$7('67((/&20321(176 3RZGHUFRDWHG VWHHO FRPSRQHQWV VXFK DV VWHHO SRVWV DQG IUDPHV DUH SURWHFWHG DJDLQVW GDPDJH GXH WR IDLOXUH RU FRUURVLRQ RI PHWDO SDUWV WKDW FDXVH WKH SURGXFW WR EHFRPH VWUXFWXUDOO\XQILWIRUWKHLQWHQGHGXVH
),9(<($5/,0,7(':$55$17<21%$5&+,0($1'&<0%$/$77$&+0(17 7KH DWWDFKPHQW V\VWHPV IRU DQ\ EDU FKLPH RU F\PEDOV DUH FRYHUHG LI IDLOXUH GXH WR EUHDNLQJ VKHDULQJ DQGRU UXVW FDXVHV WKH SURGXFW WR EHFRPH XQILW IRU LWV LQWHQGHG XVH RU DIIHFWVWKHWRQDOTXDOLW\RIWKHLQVWUXPHQW
Freenotes Harmony Park | 544 Chestnut Street | Chattanooga, TN | 37402 | 833.262.1569 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1114 of 1214 Page 1144 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1115 of 1214

8.4 SKATEPARK
SEE PLAN NO. SK1.0 TO SK9.1 FOR DETAIL INFORMATION

Page 1145 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1116 of 1214

CANTILEVERED CURVED GRIND OUT LEDGE

CURVED SLAPPY CURB QUARTERPIPE EXTENSION QUARTERPIPE ROLLOVER

RAINBOW RAIL ROUND SLAPPY GRIND RAIL

INSET SLAPPY MANUAL PAD

LA HIGH WALL QUARTERPIPE EXTENSION

ROLL-IN QUARTERPIPE ROLL-IN

ROLLOVER

CURVED QUARTERPIPE

EXTENSION

ROLL-IN
3D PERSPECTIVE

ROLL-IN

ROLL-IN CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET CUDAHY, CA. 90201
323-773-5143 CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200 COMPREHENSIVE

INNOVATIVE
TRUSTED Know what's below. Call before you dig.
® PLAN NO. 100% SUBMITTAL - PROGRESS DRAWINGS SK1.0

Page 1146 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1117 of 1214

8.5 PICNIC SHADE SHELTER

Page 1147 of 1692 ends

R
A Division of PORTERCORP 4240 N. 136th AVE HOLLAND, MI 49424 (616) 888-3500 GENERAL:
2022 CALIFORNIA BUILDING CODE
RISK CATEGORY: II
DEAD LOAD:

ROOF DEAD LOAD: 6 PSF
FRAME DEAD LOAD: SELF WEIGHT
LIVE LOAD:

ROOF LIVE LOAD: 20 PSF
SNOW DESIGN DATA:

GROUND SNOW LOAD (Pg): 0 PSF
FLAT ROOF SNOW LOAD (Pf): 0 PSF
SNOW EXPOSURE FACTOR (Ce): 1.0
SNOW LOAD IMPORTANCE FACTOR (Is): 1.0
THERMAL FACTOR (Ct): 1.2
ROOF SLOPE FACTOR (Cs): 1.0
DRIFT SURCHARGE LOAD (Pd): 0 PSF
WIDTH OF SNOW DRIFT (w): 0 FT
MINIMUM HORIZONTAL SEPARATION DISTANCE (s): 20 FT
WIND DESIGN DATA:

BASIC WIND SPEED (V): 95 MPH
ALLOWABLE STRESS DESIGN WIND SPEED (Vasd): 74 MPH
GUST EFFECT FACTOR (G): 0.85
INTERNAL PRESSURE COEFFICIENT (GCpi): 0
WIND EXPOSURE: C

SEISMIC DESIGN DATA:

STEEL ORDINARY CANTILEVER

COLUMN SYSTEMS
SEISMIC IMPORTANCE FACTOR (Ie): 1.0
SEISMIC DESIGN CATEGORY: D
SEISMIC SITE CLASS: D DEFAULT
SHORT SPECTRAL RESPONSE (Ss): 1.75
1-SEC SPECTRAL RESPONSE (S1): 0.63
DESIGN SHORT SPECTRAL RESPONSE (SDS): 1.40
DESIGN 1-SEC SPECTRAL RESPONSE (SD1): 1.06
SEISMIC RESPONSE COEFFICIENT (Cs): 1.12
RESPONSE MODIFICATION COEFFICIENT (R): 1.25

EQUIVALENT LATERAL FORCE PROCEDURE

SEE CALCULATIONS FOR ADDITIONAL DATA
ADDITIONAL CRITERIA:

NONE
R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
A653
AWS CERTIFIED WELDING FABRICATOR #221003F
GENERAL NOTES:

1. UNLESS NOTED OTHERWISE, THIS STRUCTURE WAS DESIGNED TO ONLY SUPPORT WHAT IS SHOWN ON THESE DRAWINGS. POLIGON MUST BE CONTACTED IF ANYTHING ELSE IS TO BE ATTACHED TO THIS STRUCTURE (WALLS, COLUMN WRAPS, RAILINGS, ETC.) SO THE DESIGN OF THIS STRUCTURE CAN BE REVIEWED AND POSSIBLY REVISED.

2. THE ENGINEERING SEAL FOR THE STRUCTURE DETAILED IN THESE DRAWINGS IS ONLY VALID IF PORTER CORP DESIGNS AND FABRICATES THE STEEL COMPONENTS.

FABRICATING THE STEEL COMPONENTS ELSEWHERE VOIDS THE ENGINEERING PROVIDED BY PORTER CORP.

3. UNLESS NOTED OTHERWISE, THIS STRUCTURE WAS DESIGNED ASSUMING A 20'

SEPARATION BETWEEN ANY ADJACENT STRUCTURE WITH AN EAVE HEIGHT EQUAL TO OR GREATER THAN THE EAVE HEIGHT OF THIS STRUCTURE (SEE SNOW DESIGN DATA). IF THAT SEPARATION DOES NOT EXIST AND THE GROUND SNOW LOAD (Pg) IS GREATER THAN 0

PSF, POLIGON MUST BE CONTACTED SO THE DESIGN OF THIS STRUCTURE CAN BE REVIEWED AND POSSIBLY REVISED.

4. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE

WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION MANUAL REFERENCED IN THE GOVERNING BUILDING CODE.

5. ALL WELDING IS PERFORMED BY AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS AND CONFORMS TO AWS D1.1 OR D1.3 AS REQUIRED.

6. PARTS SHOWN MAY BE UPGRADED DUE TO STANDARDIZED FABRICATION. REFER TO THE

SHIPPING BILL OF MATERIALS AND FINAL INSTALLATION INSTRUCTIONS INCLUDED WITH THE STRUCTURE FOR POSSIBLE SUBSTITUTIONS AND IMPROVEMENTS.

7. FOR PROPER FIELD INSTALLATION OF THE BUILDING IT IS RECOMMENDED THAT THE PRIMARY FRAME INSTALLER AND THE ROOF INSTALLER HAVE A MINIMUM FIVE (5) YEARS DOCUMENTED EXPERIENCE INSTALLING THIS TYPE OF PRODUCT.

8. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL

SUPERVISE AND DIRECT THE WORK, AND SHALL BE SOLELY RESPONSIBLE FOR

CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BRACING, SHORING, LAYDOWN AND PROTECTION OF CONSTRUCTION MATERIALS, ETC.

TEMPORARY SHORING AND BRACING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

9. FOR PROPER FIELD INSTALLATION OF THE BUILDING IT IS RECOMMENDED THAT ELECTRIC

WIRING, IF REQUIRED, BE RUN THROUGH THE STRUCTURAL MEMBERS BEFORE THE BUILDING IS ERECTED.

10. MAKING HOLES, CUTS OR MODIFICATIONS TO THE STRUCTURAL STEEL MEMBERS IS NOT PERMITTED IN THE FIELD WITHOUT SPECIFIC APPROVAL OF POLIGON.

CERTIFICATES:

MIAMI-DADE COUNTY CERTIFICATE OF COMPETENCY NO. 23-0915.11 PCI (POWDER COATING INSTITUTE) 4000 CERTIFIED
FABRICATOR APPROVALS:

CITY OF PHOENIX, AZ APPROVED FABRICATOR #C08-2010
CITY OF LOS ANGELES, CA APPROVED FABRICATOR #FB01596
CITY OF RIVERSIDE, CA APPROVED FABRICATOR #SF_000042
CITY OF HOUSTON, TX APPROVED FABRICATOR #470
CLARK COUNTY, NV APPROVED FABRICATOR #264
STATE OF UTAH APPROVED FABRICATOR 02008-14
AISC APPROVED FABRICATOR C-00024530

ANCHOR BOLTS
MATERIALS:

DESCRIPTION

TUBE STEEL

SCHEDULE PIPE

RMT PIPE

LIGHT GAGE COLD FORMED

STRUCTURAL STEEL PLATE

ROOF PANELS (STEEL)
SEE SHEET 2.1

ASTM DESIGNATION
A500 (GRADE C)
A53 (GRADE B)
A519
A1003 (GRADE 50)
A36
DESIGN CRITERIA:
1:56
CS
PROJECT:

PROJECT LOCATION:

COVER SHEET
CAD MODEL:

SHEET
DRAWING:

CUDAHY, CA
PROJECT NAME:

PROJECT LOCATION:

DRAWING LIST:

BUILDING TYPE:
6/11/2024
STANDING SEAM (24 GA) OVER STAINED T & G
CREATION DATE:

ROOF TYPE:
79581

CUDAHY PARK HEX
A
PORTER CORP AS WELL AS THE FOUNDATION DESIGN, IF APPLICABLE.

ORDER NO:
11/15/2016

CUDAHY PARK HEX
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

ORDER NUMBER: 79581
HXE 16

CUDAHY, CA
MANUFACTURER NOTES:
2024C
BUILDING NUMBER: P19496

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO BUILDING

COMPONENTS DETAILED WITHIN THESE DRAWINGS AND SUPPLIED BY nathan.kellicut

SHEET NUMBER DRAWING DESCRIPTION

CS COVER SHEET
1 ARCHITECTURAL ELEVATIONS
2-2.1 ANCHOR AND FOOTING LAYOUT / DETAILS
3 STRUCTURAL FRAMING PLAN
4-4.1 FRAME CONNECTION DETAILS
5 ELECTRICAL VIEWS N/A
6-6.2 ROOF LAYOUT
7-7.2 ROOF CONNECTION DETAILS
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1118 of 1214 Page 1148 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
10'-9 11/16"
REF.
7'-6
"
CLEAR
6"
SHEET 1
PROJECT:

PROJECT LOCATION:

ARCHITECTURAL ELEVATIONS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:52
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
13'-10 3/8"
REF.
16'- 1/8"
REF.

FINISH GRADE
(ASSUMED AT CONSTANT

ELEVATION UNLESS

OTHERWISE NOTED)

FINISH GRADE
(ASSUMED AT CONSTANT

ELEVATION UNLESS

OTHERWISE NOTED)
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1119 of 1214 Page 1149 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
1 ANCHOR BOLT PATTERN
2 BASE PLATE THICKNESS: 3/4"
SHEET 2 1
13'-8 1/2"
6'-10 1/4"
6'-10 3/16"
TYP.

60.00°
TYP.

SHEET 2
PROJECT:

PROJECT LOCATION:

ANCHOR AND FOOTING LAYOUT
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:32
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO BUILDING

COMPONENTS DETAILED WITHIN THESE DRAWINGS AND SUPPLIED BY PORTER CORP AS WELL AS THE FOUNDATION DESIGN, IF APPLICABLE.

ANCHOR AND FOOTING LAYOUT NOTES:

1.ANCHORS MUST BE CENTERED IN

FOOTINGS

2. FOOTINGS MUST BE TURNED TO ALIGN

WITH COLUMN AND TRUSS
CENTERLINE.
nathan.kellicut
4 1/2"
TYP.
9"
TYP.
1'-0
"
SQ.
1 1/8" THRU

ELECTRICAL ACCESS HOLE
4X 1" THRU

ANCHOR BOLT HOLE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1120 of 1214 Page 1150 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504

1. FOUNDATIONS SHALL BEAR ON COMPETENT, UNDISTURBED SOIL OR 95% COMPACTED FILL.

IF SIGNS OF ORGANIC MATERIAL, UNCONTROLLED FILL, CLAY OR SILT, HIGH WATER TABLE

OR OTHER POSSIBLE DETRIMENTAL CONDITIONS ARE FOUND, CONSTRUCTION OF THE FOUNDATIONS MUST BE STOPPED AND A GEOTECHNICAL ENGINEER BE CONTACTED.

THE FOUNDATION DESIGN SHOWN ON THESE DRAWINGS IS NOT SITE SPECIFIC, BUT BASED ON THE PRESUMPTIVE ALLOWABLE FOUNDATION PRESSURES IN CHAPTER 18 OF THE BUILDING CODE (CLASS 5 SOIL). THE BUILDING OFFICIAL IN THE JURISDICTION IN WHICH THIS

STRUCTURE IS LOCATED MAY REQUIRE A SITE SPECIFIC GEOTECHNICAL REPORT OR LETTER

FROM A QUALIFIED LOCAL PROFESSIONAL ENGINEER ATTESTING TO WHETHER THE ACTUAL SITE CONDITIONS MEET THE ASSUMPTIONS IDENTIFIED ABOVE.

FOUNDATION NOTES:

2. NO FOUNDATIONS SHALL BE PLACED INTO OR ADJACENT TO SUBGRADE CONTAINING WATER, ICE, FROST, ORGANIC OR LOOSE MATERIAL.

3. WATER SHALL NOT BE PERMITTED TO ACCUMULATE IN FOUNDATION EXCAVATIONS.

4. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCAL FROST DEPTH REQUIREMENT PRIOR TO CONSTRUCTION.

5. IF FOUNDATIONS SHOWN DO NOT MEET LOCAL FROST DEPTH REQUIREMENTS, EXTEND THE

DRILLED PIER FOUNDATION AS REQUIRED, EXTENDING THE VERTICAL BARS AND PROVIDING ADDITIONAL TIES TO MEET SPACING REQUIREMENTS AS SHOWN. IF FROST DEPTH

REQUIREMENTS ARE NOT MET, AND NO DRILLED PIER DESIGN IS PROVIDED, CONTACT POLIGON.

6. ALLOWABLE SOIL PRESSURES (AS APPLICABLE):
(TYPICAL WITH EACH COLUMN, QTY OF REINFORCING AND ANCHOR BOLTS ENSURE 3" CLEAR DISTANCE BETWEEN

EDGE OF REINFORCING AND EDGE OF

CONCRETE FOOTING (TOP, SIDE, AND BOTTOM)

MINIMUM
SEE SHEET 1
COLUMN
(LOCATED AT CENTER OF FOOTING)

FINISHED GRADE
(ASSUMED AT CONSTANT ELEVATION

UNLESS OTHERWISE NOTED)

TOP OF CONCRETE FOOTING

PIER FOOTING OPTION (EXTERNAL ANCHOR BOLTS)
2 TIES IN THE TOP 5"
(4) PLACES
(ENSURE 4

EXPOSED FROM TOP

OF FOOTING)
Ø

ANCHOR BOLT
(4) PLACES

EMBEDMENT FROM TOP

OF FOOTING TO TOP OF

HEAD/THREADED NUT)

NON-SHRINK GROUT UNDER
BASEPLATE (1-1/2" MAXIMUM)
+1/2"
-0"
Ø

OPTIONAL SLAB &

EXPANSION MATERIAL

NOT BY MANUFACTURER

EXPANSION MATERIAL ON ALL SIDES OF COLUMN
FOOTING DESIGN BY MANUFACTURER, FOOTING MATERIALS BY OTHERS.

SPECIFIED IN NOTES REFLECT SITE SPECIFIC REQUIREMENTS)
7'-6" (9) #7 VERTICAL BARS (EQ. SPACED)
#4 HORIZONTAL TIES AT 5.25" O.C. WITH
(2) 3/4" NUT
(2) 3/4" WASHER
3/4" X 15.75" LONG
(11" EFFECTIVE
3'-0"
ANCHOR RODS TO BE ASTM F1554 GRADE 55 TYPE S1 WITH "UNC" CLASS 2A THREADS, HEAVY HEX NUTS AND STANDARD CUT WASHERS, CONCRETE NOTES:

1. ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE CURRENT “ACI MANUAL OF CONCRETE PRACTICE”.

2. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 TYPE II OR TYPE V.

3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE CONCRETE MIX DESIGN MEETS THE "ACI MANUAL OF CONCRETE PRACTICE" REQUIREMENTS FOR CONCRETE BY EXPOSURE CLASS.

4. THE USE OF CHLORIDE ACCELERATORS IS NOT PERMITTED.

5. COARSE AGGREGATE SHALL BE #57 OR LARGER.

6. CONCRETE AT PLACEMENT SHALL HAVE A SLUMP OF 4" +/- 1".

7. MINIMUM CONCRETE COMPRESSIVE STRENTGH AT 28 DAYS: 4500 PSI.

8. REINFORCING STEEL SHALL BE DEFORMED STEEL CONFORMING TO THE REQUIREMENTS OF ASTM A615 (DEFORMATIONS SHALL BE IN ACCORDANCE WITH ASTM A305) AS FOLLOWS:

GRADE 60: #4 BARS AND LARGER
GRADE 40: #3 BARS

9. PRIOR TO PLACING OF CONCRETE, REINFORCING STEEL AND EMBEDDED ITEMS SHALL BE WELL SECURED IN POSITION.

10. MAINTAIN 3" CONCRETE COVERAGE TO FACE OF BARS UNLESS OTHERWISE NOTED.

11. BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER MATERIAL LIKELY TO IMPAIR BOND. BENDS SHALL BE MADE COLD.

12. WELDING OF REINFORCEMENT IS NOT ALLOWED.

SHEET

2.1 PROJECT:

PROJECT LOCATION:

ANCHOR AND FOOTING DETAILS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:12
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO BUILDING

COMPONENTS DETAILED WITHIN THESE DRAWINGS AND SUPPLIED BY PORTER CORP AS WELL AS THE FOUNDATION DESIGN, IF APPLICABLE. nathan.kellicut
ANCHOR BOLT NOTES - EXTERNAL (ANCHOR BOLTS LOCATED OUTSIDE COLUMN):

1. UNLESS
OTHERWISE NOTED.

2. ANCHOR BOLTS SHALL BE EITHER "HEADED" OR "THREADED WITH NUT" AS DEFINED IN THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION MANUAL.

3. HOOKED ANCHOR BOLTS ARE NOT ACCEPTABLE.

4. ACCURATE ANCHOR BOLT PLACEMENT IS CRITICAL. TO ENSURE THE ANCHOR BOLT LAYOUT MEETS THE DIMENSIONS REQUIRED ON THE DRAWINGS, SURVEY (OR MEASURE) THE LOCATION OF ALL ANCHOR BOLTS PRIOR TO POURING THE FOOTINGS. AN ADDITIONAL SURVEY (OR MEASUREMENT) SHOULD BE MADE AFTER THE FOOTINGS ARE POURED TO CONFIRM THE ANCHOR BOLTS DID NOT SHIFT DURING THE CONCRETE POUR.

5. THE MANUFACTURER STRONGLY RECOMMENDS USING ANCHOR BOLT TEMPLATES BECAUSE THEY SIGNIFICANTLY IMPROVE THE ACCURACY OF ANCHOR BOLT PLACEMENT. AN ANCHOR BOLT TEMPLATE IS PROVIDED WITH ANY ANCHOR BOLT KIT PURCHASED.

6. IF OUTSIDE CONSULTING ENGINEERS ARE DESIGNING THE FOUNDATIONS FOR THIS STRUCTURE, THEY MUST REFER TO THE MANUFACTURER'S CALCULATIONS FOR MINIMUM CONCRETE PROPERTIES (COMPRESSIVE STRENGTH, EDGE DISTANCE, ETC.) REQUIRED FOR THE ANCHOR BOLT DESIGN.

7. ELECTRICAL ACCESS HOLE IS ALWAYS LOCATED IN THE COLUMN BASE PLATE AS SHOWN. TEMPLATE MUST BE REMOVED BEFORE INSTALLING COLUMNS.

8. GROUT UNDER BASEPLATES SHALL BE NON-METALLIC, NON-SHRINK GROUT WITH MINIMUM f'c=6500 PSI.

9. THE CALCULATIONS FOR THIS STRUCTURE ASSUME A FIXED COLUMN BASE.

THE FOLLOWING ADHESIVE ANCHORS MAY BE SUBSTITUTED FOR THE CAST-IN-PLACE ANCHOR BOLTS:
-HILTI HIT-HY 200 (A OR R) V3 ADHESIVE WITH Ø 3/4" HAS-E ROD WITH 11" EFFECTIVE EMBEDMENT.

CONTRACTOR SHALL FOLLOW ALL INSTALLATION SPECIFICATIONS AND REQUIREMENTS OF ANCHOR MANUFACTURER.

10. 13. ALL EXPOSED EXTERNAL CORNER OF FOUNDATIONS TO BE CHAMFERED BY 3/4" BY 45 DEGREES UNLESS NOTED OTHERWISE.

14. ALL NEW CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OF REMOVING FORMWORK. CURING SHALL BE EITHER A MOIST CURE METHOD OR THE USE OF A CURING COMPOUND.

DRILLED PIER
VERTICAL BEARING 1500 PSF
LATERAL BEARING 100 PSF/FT
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1121 of 1214 Page 1151 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
10'-4 3/16"
6"
SHEET 4
K-100
SHEET 4
T-100
SHEET 4.1
G-100
7'-6
"
CLEAR
6"
SHEET 3
PROJECT:

PROJECT LOCATION:

STRUCTURAL FRAMING PLAN
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:52
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
ITEM QTY. PART NO. DESCRIPTION MATERIAL WEIGHT
4 1 - HEX C-RING ASM 3/8" PLATE 29.12
3 6 - T-MEM ASM HSS5"X3"X1/8" 44.89
2 6 - TRUSS ASM HSS6"X4"X1/8" 58.52
1 6 - COLUMN ASM HSS6"X6"X3/16" 153.85

FINISH GRADE
(ASSUMED AT CONSTANT

ELEVATION UNLESS

OTHERWISE NOTED)
1 3
2 4

FINISH GRADE
(ASSUMED AT CONSTANT

ELEVATION UNLESS

OTHERWISE NOTED)
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1122 of 1214 Page 1152 of 1692 120.00°+
-
30°
30°
STEP TWO:

AFTER SNUG TIGHT,

MATCH MARK PLATE
TO MEET AISC REQUIREMENTS.

TURN-OF-NUT PRETENSIONING METHOD:

THESE STEPS ILLUSTRATE THE

REQUIREMENTS OUTLINED IN THE AISC
SPECIFICATION. THE ROTATION

INDICATED IS ACCURATE FOR MOST

BOLT DIAMETERS AND LENGTHS BUT IT IS

THE RESPONSIBILITY OF THE INSTALLER

THEN TURN BOLT/NUT PAST
SNUG TIGHT 1/3 TURN
STEP ONE:

COLUMN CONNECTIONS K-100
R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
COMPRESSION MEMBER CONNECTION T-100

10. TEMPORARY SHORING OR BRACING SHALL BE USED TO COMPACT THE JOINTS UNTIL THE CONNECTED PLIES ARE IN FIRM CONTACT PRIOR TO PRETENSIONING.

SHEET
4 PROJECT:

PROJECT LOCATION:

FRAME CONNECTION DETAILS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:4
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
NOTE:

SEE UC-100 FOR U-CLIP INSTALLATION
CONNECTION NOTES:

1. HIGH STRENGTH BOLTS SHALL BE ASTM F3125 (A325, TYPE 1) MATERIAL.

2. HIGH STRENGTH NUTS SHALL BE ASTM A563 (GRADE DH) MATERIAL.

3. HIGH STRENGTH WASHERS SHALL CONFORM TO ASTM F436.

4. UNLESS A SNUG-TIGHT JOINT IS PERMITTED IN THE CONNECTION DETAIL, ALL BOLTS ARE TO

BE INSTALLED BY ONE OF THE FOLLOWING PRETENSIONING METHODS AS SPECIFIED IN THE AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS", SECTION 8:

A. TURN-OF-NUT PRETENSIONING
B. CALIBRATED WRENCH PRETENSIONING

5. THE SNUG-TIGHT CONDITION IS THE TIGHTNESS THAT IS ATTAINED WITH A FEW IMPACTS OF

AN IMPACT WRENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN ORDINARY SPUD WRENCH TO BRING THE CONNECTED PLIES INTO FIRM CONTACT.

6. ANCHOR BOLTS NEED NOT BE TIGHTENED PAST SNUG-TIGHT.

7. WHEN INSTALLING BOLTS REFER TO SECTIONS 8.4.1, 8.4.2, AND 8.4.3 OF THE "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS" FOR GUIDANCE.

8. LOCAL JURISDICTIONS MAY REQUIRE AN INSPECTOR TO BE PRESENT TO WITNESS HARDWARE INSTALLATION AND INDEPENDENT TESTING. INSPECTION REQUIREMENTS SHOULD BE VERIFIED BY INSTALLER PRIOR TO STEEL ERECTION.

9. ERECTION OF THE FRAMING MEMBERS WILL REQUIRE THE MAIN COLUMNS TO BE PLUMB

SQUARE AND TIGHTENED TO THE TRUSSES AND/OR TENSION MEMBERS BEFORE INSTALLING THE PURLINS. PURLINS, IF REQUIRED, MUST BE AS SHOWN IN FRAMING PLAN.

11. PRIOR TO THE ERECTION OF SHELTER COMPONENTS, IT IS RECOMMENDED TO CHASE AND TAP STRUCTURAL HARDWARE.

12. ALL BOLTS MUST BE LUBRICATED WITH WAX TO ASSIST IN PROPER TIGHTENING. TO LUBRICATE A BOLT IN THE FIELD, APPLY THE WAX STICK DOWN THE LENGTH OF THE BOLT’S THREADS.

13. TO PREVENT RUST STAINING OF FINISH, ALL METAL SHAVINGS MUST BE REMOVED AFTER INSTALLATION. ENSURE NO SHAVING ARE TRAPPED BETWEEN MATING SURFACES.

14. TOUCH-UP PAINT MUST BE APPLIED TO ALL EXPOSED FASTENERS. PERIODIC TOUCH-UP AT THESE CONNECTIONS IS REQUIRED.

TENSION MEMBER

TENSION MEMBER
TRUSS
BOLT, HEX, 5/8-11x1-1/2
(2) PLCS EACH CONNECTION
3/8" PLATE 3/8" PLATE
3/8" PLATE
TRUSS TAIL (HSS4"X4"X1/8")

WELDED TO COLUMN
NUT, HEX, 5/8-11 A563
(2) PLCS EACH CONNECTION
COLUMN
TRUSS

COMPRESSION
RING
BOLT, HEX, 5/8-11x1-3/4 A325
(2) PLCS EACH CONNECTION
3/8" PLATE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1123 of 1214 Page 1153 of 1692

U-CLIP SHOULD NOT IF TUBE HAS DRAIN HOLES
NEAR TUBE END, ATTACH U-CLIP REST ON WELD SEAM SO HOLES FACE UP. PRIOR TO BUILDING ASSEMBLY.

INSIDE FACE
U-CLIP

OUTSIDE FACE

OF TENSION MEMBER
12-24 X 1 1/2" ONE STEP SCREW
(1P2905)
12" O.C. BOTH SIDES

OF TENSION MEMBER

REMOVE METAL SHAVINGS
UC-100
NOTE:

U-CLIP MUST BE ATTACHED TO

TENSION MEMBER AS SHOWN

U-CLIP CONNECTION
R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
COLUMN GUSSET DETAIL G-100
SHEET

4.1 PROJECT:

PROJECT LOCATION:

FRAME CONNECTION DETAILS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:4
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
1/4" PLATE
(4) PLACES
COLUMN
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1124 of 1214 Page 1154 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
SHEET 7
TGSS-100
SHEET 7
TGSS-300
SHEET 7.1
TGSS-601
SHEET 7.1
TGSS-800
SHEET 7.2
TGSS-900
SHEET 6
PROJECT:

PROJECT LOCATION:

ROOF OVERVIEW
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:28
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1125 of 1214 Page 1155 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504

6. FOR BEST APPEARANCE POLIGON SUGGESTS THAT
ALL END JOINTS BE MITERED @ 45°
TONGUE & GROOVE NOTES:

1. THE FIRST PLANK SHOULD BE INSTALLED PLUMB, STRAIGHT, AND ACCURATELY TO THE ADJACENT WORK. MAKE SURE PLANKS EXTEND ENOUGH TO COVER EAVE, TRUSSES, AND/OR THE CENTER OF THE PEAK.

2. THE T&G PROVIDED MAY CONTAIN SOME MINOR IMPERFECTIONS.

REMOVE THESE IMPERFECTIONS AS REQUIRED AND USE REMAINDER OF MATERIAL TO ATTAIN MAXIMUM YIELD.

3. NO END JOINTS IN DECKING BETWEEN STRUCTURAL FRAMING AND EAVE OF DECKING.

4. A MINIMUM OF 24" SPACING IS REQUIRED BETWEEN ALL ADJACENT END JOINTS. BOARD LAYOUT MAY REQUIRE VISIBLE SPLICES.

5. IF PRE-STAINED T&G IS ORDERED, TOUCH-UP AT FIELD CUT EDGES MAY BE NECESSARY.

POLIGON RECOMMENDS ALL T&G BE STAINED/SEALED TO IMPROVE LONG TERM PERFORMANCE.
12"
5"
4 1/4"
7'-2 1/16"
SHEET

6.1 PROJECT:

PROJECT LOCATION:

ROOF LAYOUT
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:28
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut

TENSION MEMBER

COMPRESSION
RING

CEDAR FASCIA

TONGUE & GROOVE ROOF
7'-2 1/16"
8'-1 9/16"
7'-7 3/4"
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1126 of 1214 Page 1156 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
7 13/16"
12 "
5"
SHEET

6.2 PROJECT:

PROJECT LOCATION:

ROOF LAYOUT
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
1:28
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
STANDING SEAM INSTALLATION NOTES:

1. THE DETAILS SHOWN ARE SUGGESTIONS OR GUIDELINES ON HOW TO ERECT THE SYSTEMS. THE INFORMATION SHOWN IS ACCURATE, BUT IT

IS NOT INTENDED TO COVER ALL INSTANCES, BUILDING
REQUIREMENTS, DESIGNS OR CODES. THE DETAILS MAY REQUIRE CHANGES OR REVISIONS DUE TO FIELD CONDITIONS.

2. IT SHALL BE THE RESPONSIBILITY OF THE ERECTOR TO ENSURE THAT THE

DETAILS MEET PARTICULAR BUILDING REQUIREMENTS AND TO
ASSURE ADEQUATE WATER TIGHTNESS.

3. THE ERECTOR SHOULD THOROUGHLY FAMILIARIZE HIMSELF/HERSELF WITH ALL ERECTION INSTRUCTIONS BEFORE STARTING WORK.

4. THE PANELS SHOULD BE INSTALLED PLUMB, STRAIGHT, AND
ACCURATELY TO THE ADJACENT WORK.

5. FLASHING AND TRIM SHALL BE INSTALLED TRUE, AND IN PROPER

ALIGNMENT, WITH ANY EXPOSED FASTENERS EQUALLY SPACED FOR THE BEST APPEARANCE.

6. SEALANT SHALL BE FIELD APPLIED ON DRY, CLEAN SURFACES. SOME

FIELD CUTTING AND FITTING OF PANELS AND FLASHING IS TO BE

EXPECTED BY THE ERECTOR AND MINOR FIELD CORRECTIONS ARE A PART OF NORMAL ERECTION WORK.

7. WORKMANSHIP SHALL BE OF THE BEST INDUSTRY STANDARDS AND

INSTALLATION SHALL BE PERFORMED BY EXPERIENCED METAL
CRAFTSMEN.

8. METAL SHAVINGS FROM DRILLING OR INSTALLATION OF ROOF

FASTENERS MUST BE CAREFULLY REMOVED FROM THE ROOF BY

BRUSHING OR SWEEPING AT THE END OF EACH DAY DURING
INSTALLATION. SHAVINGS LEFT ON THE ROOF WILL QUICKLY RUST AND STAIN THE ROOF FINISH.

STANDING SEAM PANELS
NEED TO BE FIELD CUT TO LENGTH.

STANDING SEAM PANELS

MUST BE INSTALLED LEFT TO RIGHT
7'-11 5/16"
7'-5 7/16"
8'-5 5/16"

CEDAR FASCIA TENSION MEMBER

COMPRESSION
RING
STANDING SEAM ROOF (24 GA)

TONGUE & GROOVE ROOF
2"
7'-5 7/16"
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1127 of 1214 Page 1157 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
#12-14x3/4" SELF DRILLING SCREW
#9x1" WOODGRIP SCREW
PART DESCTIPTIONS:
1/8" POP RIVET
1" GALVANIZED

ROOFING NAIL
(NOT BY POLIGON)
#6 x 2" GALV. COATED

DECK SCREW
#12-24x2.75 TRAXX/4 SCREW
APPLY 3/4 LBS. (165 NAILS) OF NAILS PER 100 SQ. FT.
2022A
NOTE:

WHEN NAILING DOWN FELT TO THE T&G DECKING
EVENLY DISPERSED. (NAILS NOT BY POLIGON)
TGSS-100
(ALONG TOP AND BOTTOM OF OFFSET CLEAT)

BUTYL TAPE
(2) EACH CLIP

HEAD WOODGRIP SCREW
#10 X 1" PANCAKE
(36" O.C. UP ROOF)
(3" FROM EAVE)

ROOF CLIP

T&G DECKING
30# FELT (2) PER BOARD
TRAXX/4 SCREW
#12-24 X 2 3/4"

TENSION MEMBER
(24" O.C.)

DECK SCREW
#6 X 2" GALV. COATED
(STAGGERED 24" O.C.)

DECK SCREW
#6 X 2" GALV. COATED
2" x 3" NAILER
1" X 4" CEDAR FASCIA

METAL EAVE FASCIA
(WRAP CEDAR FASCIA)

STARTER LAYER OF FELT

OFFSET CLEAT
STANDING SEAM PANEL (24 GA.)
(12" O.C.)

HEAD WOODGRIP SCREW
#10 X 1" PANCAKE

METAL EAVE FASCIA

SLIDE AROUND PANEL

FIELD BEND PANEL

EAVE DETAIL
APPLY 3/4 LBS. (165 NAILS) OF NAILS PER 100 SQ. FT.
2023A
NOTE:

WHEN NAILING DOWN FELT TO THE T&G DECKING
EVENLY DISPERSED. (NAILS NOT BY POLIGON)

C-CLOSURE
TRUSS DETAIL TGSS-300
#12-24 X 2 3/4" TRAXX/4 SCREW
(2) PER BOARD

T&G DECKING
TRUSS
STANDING SEAM PANEL (24 GA.)

HIP CAP
#9 X 1" WOODGRIP SCREW
(EACH SIDE OF RIB)
30# FELT
(WRAP OVER HIP)
#12-14 X 3/4" SELF

DRILLING SCREW
(12" O.C.)

HIP CAP
(6" OVERLAP)

BUTYL TAPE
(ALONG TOP, BOTTOM & ENDS OF C-CLOSURE)
(CUT TO FIT BETWEEN RIBS)
SHEET
7 PROJECT:

PROJECT LOCATION:

ROOF CONNECTION DETAILS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
NTS
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1128 of 1214 Page 1158 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
APPLY 3/4 LBS. (165 NAILS) OF NAILS PER 100 SQ. FT.
2022A
NOTE:

WHEN NAILING DOWN FELT TO THE T&G DECKING
EVENLY DISPERSED. (NAILS NOT BY POLIGON)

HIP CAP
ROOF PEAK DETAIL TGSS-800

C-CLOSURE
STANDING SEAM PANEL (24 GA.)
(EACH CORNER OF ROOF PEAK CAP)
#12-14 X 3/4" SELF DRILLING SCREW ROOF PEAK CAP

T&G DECKING
EVENLY DISPERSED. (NAILS NOT BY POLIGON)
NOTE:

WHEN NAILING DOWN FELT TO THE T&G DECKING
APPLY 3/4 LBS. (165 NAILS) OF NAILS PER 100 SQ. FT.
2022A MID SPAN DETAIL
(36" O.C. SPACING)

ROOF CLIP

WOODGRIP SCREWS
(2) #10 X 1" PANCAKE HEAD

ROOF CLIP
30# FELT
STANDING SEAM PANEL (24 GA.)

T&G DECKING
TGSS-601
SHEET

7.1 PROJECT:

PROJECT LOCATION:

ROOF CONNECTION DETAILS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
NTS
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1129 of 1214 Page 1159 of 1692 R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
EVENLY DISPERSED. (NAILS NOT BY POLIGON)
NOTE:

WHEN NAILING DOWN FELT TO THE T&G DECKING
APPLY 3/4 LBS. (165 NAILS) OF NAILS PER 100 SQ. FT.
2022A CORNER DETAIL

C-CLOSURE

DOWN TO COVER OPENING

CUT AND BEND HIP CAP

METAL EAVE FASCIA

HIP CAP

METAL EAVE FASCIA
STANDING SEAM PANEL (24 GA.)

T&G DECKING
TGSS-900
2022A

HEM STANDING SEAM
-STANDING SEAM PANELS COME PRE-NOTCHED FROM THE FACTORY -PANELS MUST BE INSTALLED FROM LEFT TO RIGHT (FEMALE LEG ON LEFT, MALE LEG ON THE RIGHT -HEM TOOL NOT PROVIDED AS PART OF THE ROOF KIT

HEM DETAIL SS HEM

HEM TOOL

SLIDE OVER PANEL
STANDING SEAM PANEL (24 GA.)

FINISHED HEM

PANEL OVER OFFSET CLEAT
SHEET

7.2 PROJECT:

PROJECT LOCATION:

ROOF CONNECTION DETAILS
CAD MODEL: DRAWING:

CUDAHY PARK HEX
CUDAHY, CA 79581
ORDER NO:

A
CREATION DATE:
11/15/2016
NTS
6/11/2024
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO

BUILDING COMPONENTS (AND FOUNDATION DESIGN IF APPLICABLE) DETAILED WITHIN THESE DRAWINGS.
nathan.kellicut
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1130 of 1214 Page 1160 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1131 of 1214 R
A Division of PORTERCORP 4240 N. 136th AVE HOLLAND, MI 49424 (616) 888-3500 GENERAL:
2022 CALIFORNIA BUILDING CODE
RISK CATEGORY: II
DEAD LOAD:

ROOF DEAD LOAD: 6 PSF
FRAME DEAD LOAD: SELF WEIGHT
LIVE LOAD:

ROOF LIVE LOAD: 20 PSF
SNOW DESIGN DATA:

GROUND SNOW LOAD (Pg): 0 PSF
FLAT ROOF SNOW LOAD (Pf): 0 PSF
SNOW EXPOSURE FACTOR (Ce): 1.0
SNOW LOAD IMPORTANCE FACTOR (Is): 1.0
THERMAL FACTOR (Ct): 1.2
ROOF SLOPE FACTOR (Cs): 1.0
DRIFT SURCHARGE LOAD (Pd): 0 PSF
WIDTH OF SNOW DRIFT (w): 0 FT
MINIMUM HORIZONTAL SEPARATION DISTANCE (s): 20 FT
WIND DESIGN DATA:

BASIC WIND SPEED (V): 95 MPH
ALLOWABLE STRESS DESIGN WIND SPEED (Vasd): 74 MPH
GUST EFFECT FACTOR (G): 0.85
INTERNAL PRESSURE COEFFICIENT (GCpi): 0
WIND EXPOSURE: C

SEISMIC DESIGN DATA:

STEEL ORDINARY CANTILEVER

COLUMN SYSTEMS
SEISMIC IMPORTANCE FACTOR (Ie): 1.0
SEISMIC DESIGN CATEGORY: D
SEISMIC SITE CLASS: D DEFAULT
SHORT SPECTRAL RESPONSE (Ss): 1.75
1-SEC SPECTRAL RESPONSE (S1): 0.63
DESIGN SHORT SPECTRAL RESPONSE (SDS): 1.40
DESIGN 1-SEC SPECTRAL RESPONSE (SD1): 1.06
SEISMIC RESPONSE COEFFICIENT (Cs): 1.12
RESPONSE MODIFICATION COEFFICIENT (R): 1.25

EQUIVALENT LATERAL FORCE PROCEDURE

SEE CALCULATIONS FOR ADDITIONAL DATA
ADDITIONAL CRITERIA:

NONE
R
MAIN: (616) 888-3500
by PORTER CORP
WWW.POLIGON.COM
FIELD SUPPORT: (616) 888-3504
A653
AWS CERTIFIED WELDING FABRICATOR #221003F
GENERAL NOTES:

1. UNLESS NOTED OTHERWISE, THIS STRUCTURE WAS DESIGNED TO ONLY SUPPORT WHAT IS SHOWN ON THESE DRAWINGS. POLIGON MUST BE CONTACTED IF ANYTHING ELSE IS TO BE ATTACHED TO THIS STRUCTURE (WALLS, COLUMN WRAPS, RAILINGS, ETC.) SO THE DESIGN OF THIS STRUCTURE CAN BE REVIEWED AND POSSIBLY REVISED.

2. THE ENGINEERING SEAL FOR THE STRUCTURE DETAILED IN THESE DRAWINGS IS ONLY VALID IF PORTER CORP DESIGNS AND FABRICATES THE STEEL COMPONENTS.

FABRICATING THE STEEL COMPONENTS ELSEWHERE VOIDS THE ENGINEERING PROVIDED BY PORTER CORP.

3. UNLESS NOTED OTHERWISE, THIS STRUCTURE WAS DESIGNED ASSUMING A 20'

SEPARATION BETWEEN ANY ADJACENT STRUCTURE WITH AN EAVE HEIGHT EQUAL TO OR GREATER THAN THE EAVE HEIGHT OF THIS STRUCTURE (SEE SNOW DESIGN DATA). IF THAT SEPARATION DOES NOT EXIST AND THE GROUND SNOW LOAD (Pg) IS GREATER THAN 0

PSF, POLIGON MUST BE CONTACTED SO THE DESIGN OF THIS STRUCTURE CAN BE REVIEWED AND POSSIBLY REVISED.

4. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED, AND ERECTED IN ACCORDANCE

WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) SPECIFICATION MANUAL REFERENCED IN THE GOVERNING BUILDING CODE.

5. ALL WELDING IS PERFORMED BY AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS AND CONFORMS TO AWS D1.1 OR D1.3 AS REQUIRED.

6. PARTS SHOWN MAY BE UPGRADED DUE TO STANDARDIZED FABRICATION. REFER TO THE

SHIPPING BILL OF MATERIALS AND FINAL INSTALLATION INSTRUCTIONS INCLUDED WITH THE STRUCTURE FOR POSSIBLE SUBSTITUTIONS AND IMPROVEMENTS.

7. FOR PROPER FIELD INSTALLATION OF THE BUILDING IT IS RECOMMENDED THAT THE PRIMARY FRAME INSTALLER AND THE ROOF INSTALLER HAVE A MINIMUM FIVE (5) YEARS DOCUMENTED EXPERIENCE INSTALLING THIS TYPE OF PRODUCT.

8. THE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL

SUPERVISE AND DIRECT THE WORK, AND SHALL BE SOLELY RESPONSIBLE FOR

CONSTRUCTION MEANS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BRACING, SHORING, LAYDOWN AND PROTECTION OF CONSTRUCTION MATERIALS, ETC.

TEMPORARY SHORING AND BRACING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

9. FOR PROPER FIELD INSTALLATION OF THE BUILDING IT IS RECOMMENDED THAT ELECTRIC

WIRING, IF REQUIRED, BE RUN THROUGH THE STRUCTURAL MEMBERS BEFORE THE BUILDING IS ERECTED.

10. MAKING HOLES, CUTS OR MODIFICATIONS TO THE STRUCTURAL STEEL MEMBERS IS NOT PERMITTED IN THE FIELD WITHOUT SPECIFIC APPROVAL OF POLIGON.

CERTIFICATES:

MIAMI-DADE COUNTY CERTIFICATE OF COMPETENCY NO. 23-0915.11 PCI (POWDER COATING INSTITUTE) 4000 CERTIFIED
FABRICATOR APPROVALS:

CITY OF PHOENIX, AZ APPROVED FABRICATOR #C08-2010
CITY OF LOS ANGELES, CA APPROVED FABRICATOR #FB01596
CITY OF RIVERSIDE, CA APPROVED FABRICATOR #SF_000042
CITY OF HOUSTON, TX APPROVED FABRICATOR #470
CLARK COUNTY, NV APPROVED FABRICATOR #264
STATE OF UTAH APPROVED FABRICATOR 02008-14
AISC APPROVED FABRICATOR C-00024530

ANCHOR BOLTS
MATERIALS:

DESCRIPTION

TUBE STEEL

SCHEDULE PIPE

RMT PIPE

LIGHT GAGE COLD FORMED

STRUCTURAL STEEL PLATE

ROOF PANELS (STEEL)
SEE SHEET 2.1

ASTM DESIGNATION
A500 (GRADE C)
A53 (GRADE B)
A519
A1003 (GRADE 50)
A36
DESIGN CRITERIA:
1:56
CS
PROJECT:

PROJECT LOCATION:

COVER SHEET
CAD MODEL:

SHEET
DRAWING:

CUDAHY, CA
PROJECT NAME:

PROJECT LOCATION:

DRAWING LIST:

BUILDING TYPE:
6/11/2024
STANDING SEAM (24 GA) OVER STAINED T & G
CREATION DATE:

ROOF TYPE:
79581

CUDAHY PARK HEX
A
PORTER CORP AS WELL AS THE FOUNDATION DESIGN, IF APPLICABLE.

ORDER NO:
11/15/2016 CUDAHY PARK HEX
~P19496
PRINT DATE:

REV LEVEL: SCALE:

DRAWN BY:

ORDER NUMBER: 79581
HXE 16

CUDAHY, CA
MANUFACTURER NOTES:
2024C
BUILDING NUMBER: P19496

IF THESE DRAWINGS ARE SEALED, THE SEAL APPLIES ONLY TO BUILDING

COMPONENTS DETAILED WITHIN THESE DRAWINGS AND SUPPLIED BY nathan.kellicut

SHEET NUMBER DRAWING DESCRIPTION

CS COVER SHEET
1 ARCHITECTURAL ELEVATIONS
2-2.1 ANCHOR AND FOOTING LAYOUT / DETAILS
3 STRUCTURAL FRAMING PLAN
4-4.1 FRAME CONNECTION DETAILS
5 ELECTRICAL VIEWS N/A
6-6.2 ROOF LAYOUT
7-7.2 ROOF CONNECTION DETAILS
Christop
her Evans
2024.06.1
3 09:55:25
-04'00'

Page 1161 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1132 of 1214

8.6 SITE FURNISHING AND AMENITIES

Page 1162 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1133 of 1214 https://outdoorcreations.com/contact.php

Page 1163 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1134 of 1214 https://outdoorcreations.com/contact.php

Page 1164 of 1692 ends

Most
Dependable
Fountains, Inc.

MODELS:
10145 SM & 10145 SMSS

OPERATIONS MANUAL
Most Dependable Fountains, Inc™
5705 Commander Drive
Arlington, TN 38002
901-867-0039
www.mostdependable.com
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1135 of 1214 Page 1165 of 1692 MODEL 10145SM
10145SM SHOWN WITH OPTIONAL 10" SS SURFACE CARRIER

FRONT VIEW
CADdetails.com
3354-17.8
PROTECTED BY COPYRIGHT ©2018 CADDETAILS.COM LTD.

REVISION DATE 08/03/2018
www.mostdependable.com FOUNTAINS,
MOST DEPENDABLE FOUNTAINS, INC.
5705 COMMANDER DR. P.O. BOX 587
ARLINGTON, TN 38002-0587
PHONE: (901) 867-0039
FAX: (901) 867-0159
FILTER
10" PIPE
OPTIONAL 10"

STAINLESS

STEEL CARRIER

WATER SUPPLY BY OTHERS

ACCESS DOOR BY MDF
5"
18"
27"
18"
19" 5" 35"
NOTES:

1. OPTIONAL STAINLESS STEEL SURFACE CARRIER RECOMMENDED.

2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.

3. DO NOT SCALE DRAWING.

4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.

5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.

6. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER REFERENCE NUMBER 3354-17.8.
11 3/4"
34"

TOP VIEW

BOLT CENTERED UNDER ADA ARM
NOTE: ANCHORED INSIDE OF PEDESTAL
46 3/4"
WATER

C/L OF WASTE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1136 of 1214 Page 1166 of 1692

PEDESTAL BOTTLE FILLER SPECIFICATIONS

WATER QUALITY (LEAD FREE)

RECEPTOR BOWL

BUBBLER HEAD

PUSH BAR

CONTROL VALVE

WATER SUPPLY (LEAD FREE)
FINISH

INSTALLATION

WINTERIZATION

WARRANTY

SHIPPING WEIGHT

STAINLESS STEEL PEDESTAL
OR
DRAIN

BOTTLE FILLER SPOUT
Section 9, California Proposition 6 and the Federal Safe Drinking Water Act.

One piece weld construction with MDF standard 3/16” wall thickness. 18 gauge electro-polished stainless steel bowl. Bowl overlaps pedestal, preventing buildup of residue in visual drinking area. Optional stainless steel Bowl Strainer recommended for areas with sand. Not applicable on Model 10125 SMSS.

Stainless steel anti-squirt head (weighing a pound and a half) mounted with a lock nut and washer to prevent tampering. Lock nut pin holds bubbler in locked position to prevent twisting or turning. The MDF bubbler head has a unique design that features a steady stream trajectory and a built in natural shield from contamination.
304 stainless steel with circumference exceeding 8.6”. Mushroom style push bar overlaps and prevents sand and other objects from sticking push bar in the ON position. Stainless steel bubbler housing standard.

Requires less than 5 lbs to operate. Non-cartridge O-ring valve delivers steady stream of water through an adjustable valve. This valve design is to operate and function at 30 to 80 PSI. Ideal operating pressure is 60 PSI.

Maintenance free reinforced nylobraid tubing - this tubing is not plastic. It is supplied with a 1/2” MIP threaded inlet with stainless steel strainer. Union fittings at every connection. Supply line stops above grade. Water Filter is standard on this model.

Oven baked powder coat. Choice of colors are: green, blue, black, red, yellow, orange, brown and white. Textured color choices: emerald, sapphire, pyrite, text-black, burgundy, gold vein, copper and sandstone. Stainless steel models are powder coated for added protection. The color chrome is an available option for stainless steel models only.

STANDARD PEDESTAL
Surface Mount installation is designed to be anchored on top of a new or existing surface (concrete, etc.) For a new surface, a surface mount carrier is recommended.

For an existing surface, anchor bolts are to be used through the attached mounting plate. Surface Mount Fountains come standard with an access door with vandal resistant stainless steel screws.

Shut off water and drain down. Remove water filter.

One year warranty, labor not included.

Model 10125 SM.....110 lbs Model 10125 SMSS...... 100 lbs Model 10890 SM........ 150 lbs Model 10135 SM.....150 lbs Model 10135 SMSS...... 150 lbs Model 10890 SMSS... 140 lbs Model 10145 SM.... 245 lbs Model 10145 SMSS...... 235 lbs Model 10895 SM........ 200 lbs Model 10150 SM.... 245 lbs Model 10150 SMSS...... 235 lbs Model 10895 SMSS... 190 lbs Model 10155 SM.... 195 lbs Model 10155 SMSS...... 185 lbs One piece weld construction with MDF standard 304 schedule 10 stainless steel. 1 1/2” schedule 40 PVC pipe. Drain line stops above grade.

Sanitary recessed nozzle.

MOST DEPENDABLE FOUNTAINS, INC.™
5705 COMMANDER DR. • ARLINGTON, TN 38002-0587
www.mostdependable.com
(901) 867-0039 LEAD FREE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1137 of 1214 Page 1167 of 1692

INSTALLATION INSTRUCTIONS
Most Dependable Fountains, Inc.™
All SM (surface mount) products are designed to be installed on the surface of a new or existing concrete slab. Your contractor needs to provide a 1 1/2” PVC drain line (when applicable) and water line thru finish grade.

Connections are made to our SM products thru our access door, as shown on detail drawings. The water tubing is provided with a 1/2” male iron pipe connection. This is an excellent location for a cutoff valve. Surface Mount units are anchored to the existing concrete by means of 1/2” concrete shields with bolts or we recommend 1/2” quick bolts.

Note: We offer an optional template which is designed to be poured in the concrete slab. It comes with the necessary vandal resistant stainless steel bolts and washers needed to anchor.

All DB (direct bury) products are designed to be installed to a depth of 14” below grade. MDF provides 1 1/2” PVC drain line inside the pedestal (when applicable) to point of connection by others. MDF also provides reinforced nylobraid flexible tubing with a 1/2” male iron pipe thread for connection to water supply by others. MDF recommends an optional valve box using a PVC conduit to the pedestal. By using this option you have complete control of your product.

Individual detail drawings available Online or by request.

For more information:

Most Dependable Fountains, Inc.™
www.mostdependable.com
[email protected]
901-867-0039
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1138 of 1214 Page 1168 of 1692

LIMITED PRODUCT WARRANTY
Most Dependable Fountains, Inc.™ warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from date of shipment. Most Dependable Fountains, Inc.™ liability under this warranty shall be discharged by furnishing without charge any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship. Most Dependable Fountains, Inc.™ will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents. Most Dependable Fountains, Inc.™ will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Most Dependable Fountains, Inc.™ has made no other warranties either expressed or implied in addition to those above stated. The products manufactured by Most Dependable Fountains, Inc.™ is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended.

Most Dependable Fountains, Inc.™
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1139 of 1214 Page 1169 of 1692 Most
Dependable
Fountains, Inc.

MODELS:

BBQ Grill

OPERATIONS MANUAL
Most Dependable Fountains, Inc™
5705 Commander Drive
Arlington, TN 38002
800-552-6331
www.mostdependable.com
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1140 of 1214 Page 1170 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1141 of 1214 Phone: 800-669-2585
Fax: 800-729-2483
Email: [email protected]

Page 1171 of 1692 ends

BBQ GRILL SM
BBQ GRILL ON SM PEDESTAL SHOWN W/ OPTIONAL 4" SS SURFACE CARRIER 3354-15.6
CADdetails.com
www.mostdependable.com FOUNTAINS,
PROTECTED BY COPYRIGHT ©2016 CADDETAILS.COM LTD.

REVISION DATE 06/13/2016
MOST DEPENDABLE FOUNTAINS, INC.
5705 COMMANDER DR. P.O. BOX 587
ARLINGTON, TN 38002-0587
TOLL FREE: 1-800-552-6331
PHONE: (901) 867-0039
FAX: (901) 867-0159
NOTES:

1. HEIGHT CAN BE ADJUSTED TO SATISFY CUSTOMER NEEDS.

2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.

3. DO NOT SCALE DRAWING.

4. THIS DRAWING IS INTENDED FOR USE BY ARCHITECTS, ENGINEERS, CONTRACTORS, CONSULTANTS AND DESIGN PROFESSIONALS FOR PLANNING PURPOSES ONLY. THIS DRAWING MAY NOT BE USED FOR CONSTRUCTION.

5. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE TIME OF DEVELOPMENT BUT MUST BE REVIEWED AND APPROVED BY THE PRODUCT MANUFACTURER TO BE CONSIDERED ACCURATE.

6. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info AND ENTER REFERENCE NUMBER 3354-15.6.
36"
20" DIAMETER
4" BLK PIPE

OPTIONAL

TEMPLATE
BY

SWIVEL OTHERS

BOTTOM FOR

ASH DUMP

BOLT CENTERED

UNDER GRILL
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1142 of 1214 Page 1172 of 1692

BBQ GRILL SPECIFICATIONS

PEDESTAL

CLEAN OUT

INSTALLATION

WARRANTY
GRATE
FINISH

SHIPPING WEIGHTS
Heavy duty steel 3/16” thick pedestal.

Easy clean out with security feature. (Door may be secured with customer’s padlock to prevent tampering.) Ashes are removed by placing a bucket under the grill and opening the door.

Surface Mount is designed to be anchored on top of an existing surface (concrete, etc.) with anchor bolts through a mounting plate that is welded to the grill. Surface Mount Carrier recommended for all surface mount installations.

One year warranty. Labor not included.

Mid-hinged steel cooking grate designed for easy access to cooking pit. Access by lifting one side at a time to add charcoal while cooking on the opposite side.

Black heat resistant powder coat.

BBQ Grill 100 lbs.

BBQ2 430 lbs.

BBQ3 465 lbs.

MOST DEPENDABLE FOUNTAINS, INC.™
(800) 552-6331 • (901) 867-0039 • Fax (901) 867-4008
5705 COMMANDER DR. • ARLINGTON, TN 38002-0587
www.mostdependable.com
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1143 of 1214 Page 1173 of 1692

LIMITED PRODUCT WARRANTY
Most Dependable Fountains, Inc.™ warrants that all of its products are guaranteed against defective material or poor workmanship for a period of one year from date of shipment. Most Dependable Fountains, Inc.™ liability under this warranty shall be discharged by furnishing without charge any goods, or part thereof, which shall appear to the Company upon inspection to be of defective material or not of first class workmanship. Most Dependable Fountains, Inc.™ will not be liable for the cost of repairs, alterations or replacements, or for any expense connected therewith made by the owner or his agents. Most Dependable Fountains, Inc.™ will not be liable for any damages caused by defective materials or poor workmanship, except for replacements, as provided above. Buyer agrees that Most Dependable Fountains, Inc.™ has made no other warranties either expressed or implied in addition to those above stated. The products manufactured by Most Dependable Fountains, Inc.™ is warranted to function if installation and maintenance instructions provided are adhered to. The units also must be used for the purpose for which they were intended.

Most Dependable Fountains, Inc.™
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1144 of 1214 Page 1174 of 1692 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1145 of 1214

8.7 TENNIS AND BASKETBALL COURT

APPARATUSES

Page 1175 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1146 of 1214 1/4" ·I· 59 1/4" ---
, -•- - - - - - - - - - - -
I
I
29 1/2" 24 1/41-''
I
I
1 1/2'' X 2 1/2''

BOLT POCKET
---�L-_t �I � rf-������ ��� �FOOTING
48" BY OTHERS
8 1/4"j t
5 1/8" I lr .. ) 8
,,

TOP VIEW
Scale: 1/2" = l'

MOUNTING FACE
1/2'' REBAR
.:I .c1.
2" ALUMINUM BRACE
(2) 5/8" INSERTS
(BRACE LOCATION)
Scale: 1/2" = 1' (2) 5/8" LIFTING INSERTS -- 47 1/4" -- (4)3/8"-16

INSERT REQ'D

BACKBOARD
HOOP ....,.----;:�,....,... -. --1\.-.-1• I r ,,
7-:---:--, . � -� I�,
'4 ( 4) 3/8" BOLT AND

LOCK WASHER

BACKBOARD MOUNTING
Scale: 1/2" = 1'
16 3/4"
i
V
.d
�·
� .., lk�>::-:-----__ '"
.

I _[ 4 1 /2'' VARIES
r-' '""' . <1 . -·">- ,ib?"i
I>, •
. I>
V 17 I> V V\7 1> !'
j;, '!'
I> -----106 1/2''----­

SECTION VIEW
Scale: 1/2" = 1'
HOOP
120"
144 1/2"
(+1/8"/-1/4")
P.O. BOX 1520 WAUSAU, WI 54402-1520
800-388-8728
E-MAIL: [email protected]
WEB SITE: WWW.WAUSAUTILE.COM

REVISIONS

NAME I DATE I NOTES
1 I TAS 111/4/16 I UPDATED DIMS
2 I TAS 14/24/17 I UPDATED DIMS
3 4
5 6
7 8

CONFIDENTIAL INFORMATION

THESE DRAWING, SPECIFICATIONS AND

OTHER INFORMATION AND DOCUMENTS

ACCOMPANYING THEM ARE THE

CONFIDENTIAL AND PROPRIETARY PROPERTY
OF WAUSAU TILE, INC. THE DRAWINGS

THEMSELVES SHALL BELONG TO THE OWNE
FOR USE ONLY ON THE PROJECT. ANY

ADDITIONAL USE SHALL REQUIRE THE PRIORI
WRITTEN APPROVAL OF WAUSAU TILE, INC.

THE PROPRIETARY INFORMATION CONTAINED

WITHIN THE DRAWINGS AND THE DOCUMENT
IS AND SHALL REMAIN THE SOLE PROPERTY!

OF WAUSAU TILE, INC
WAUSAU TILE INC.

WAUSAU, WI

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES
FRACTIONS ± 1 /8"
DRAWN BY: LBE
DATE: 6/25/08
CO NUMBER:?
WEIGHT: ?
SHEET NO. TF7175

Page 1176 of 1692 ends

HEAVY-DUTY TENNIS POSTS

BASKETBALL
28 WWW.PWATHLE TIC.C OM / 1-800-6 87-576 8 COURT SPORTS

HEAVY-DUTY TENNIS POSTS
Every post features an internal top cap to help seal out the elements. All of our posts are designed to permit 24” of depth for in-ground sleeves or permanent concrete footings.

The standard post color is green, which can be Quick Shipped, black is available at standard lead times. Nets sold separately – see below. • Posts are 3” O.D. round or 3” square, 11-gauge steel
• Cast aluminum alloy caps and gear housings
• Baked-on polyester powder coat finish
• Chrome plated gear plate and handle
• Internally wound with a self-locking gear mechanism
• Plated, steel gears
• Case hardened small gear
MODEL #2205-GRN
MODEL #2206-GRN
Heavy-Duty Tennis Posts
Model Description Weight
2205-BLK Square Tennis Posts (Black) - 1 Pair 50 lbs.
2205-GRN Square Tennis Posts (Green) - 1 Pair 50 lbs.
2206-BLK Round Tennis Posts (Black) - 1 Pair 50 lbs.
2206-GRN Round Tennis Posts (Green) - 1 Pair 50 lbs.
2206-01 3” Round Sleeve with Cap (Pair) 10 lbs.
8303A-SQ24-2 Aluminum Sleeves for Model #2205 (Pair) 8 lbs. 8303-1S Square Caps for Aluminum Sleeves (Pair) 9 lbs.

Heavy-Duty Tennis Post Replacement Parts
Model Description Weight
8410-SQBK Replacement Cap with Pulley - Square Black 10 lbs. 8410-SQGR Replacement Cap with Pulley - Square Green 10 lbs. 8410-RDBK Replacement Cap with Pulley - Round Black 10 lbs. 8410-RDGR Replacement Cap with Pulley - Round Green 10 lbs. 8411-SQBK Replacement Cap for 2nd Post - Square Black 10 lbs. 8411-SQGR Replacement Cap for 2nd Post - Square Green 10 lbs. 8411-RDBK Replacement Cap for 2nd Post - Round Black 10 lbs. 8411-RDGR Replacement Cap for 2nd Post - Round Green 10 lbs. 8412-RD Replacement Gear Assembly - Round 3 lbs.
8412-SQ Replacement Gear Assembly - Square 3 lbs.
615-024 Replacement Cap for 2nd Post 1 lbs.
615-025 Replacement Winder Handle 1 lbs.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1147 of 1214 Phone: 800-669-2585
Fax: 800-729-2483
Email: [email protected]

Page 1177 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1148 of 1214

8.8 PARK LIGHTING AND ELECTRICAL

Page 1178 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1149 of 1214

HAND HOLE OPENING
DETAIL 3 - BASE
PLATE DETAIL DETAIL 1 - ANCHOR
BOLT DETAIL 41"
4"
ASTM A36 STEEL
(4) 0.75" x 30" x 4" ANCHOR BOLTS - GALVANIZED PER ASTM A123 WITH (2) HEX NUT
AND (2) FLAT WASHERS
PER ANCHOR BOLT 30"

0.75"

2.875" x 3.75" HAND

HOLE COVER

14.125" Ø BASE PLATE

7.75" MAX. WIREWAY OPENING

11.5" BOLT CIRCLE
(4) 1.75" X 1" SLOTTED BOLT HOLES
3" x 3.875" HAND
HOLE OPENING 11"

8.0625"
2 PIECE CLAMP AROUND CASTING, A356 CAST ALUMINUM INGOT
A356 CAST ALUMINUM
INGOT

RIDGE TO PREVENT BOLT COVERS FROM BEING RAISED
DETAIL 3 - BASE PLATE DETAIL
DETAIL 4 - ANCHOR BOLT DETAIL

INTERNAL TAB TO REST ON

BASE PLATE TO ENSURE BASE COVER IS LEVEL

BASE HALVES CONECTED
TOGETHER USING (2) 1/4-20 x 1/2" STAINLESS STEEL BUTTON HEAD

CAP SCREW
DETAIL 2 - BOLT COVER DETAIL
DETAIL 2 - BOLT COVER DETAIL

14.125"

4.5" SCH. 40 PIPE
(5" O.D. x 0.247" WALL) 0.75"
* ALL HARDWARE TO BE STAINLESS STEEL
* ALL WELDS IN ACCORDANCE WITH AWS WELDING CODE
* ALL MATERIAL FINISH TOP COATED PER CUSTOMER SPECIFICATIONS; CUSTOMER TO PROVIDE COLOR SAMPLE FOR COLOR MATCH 24'-0" 26'-2.75" DETAIL 1 - ARM MOUNTING BRACKETS
28" PCR-5B REMOVABLE

POLE CAP

18.25" 1.25"Ø WIREWAY
SEE DETAIL 1 - ARM MOUNTING

BRACKETS
2" NPT NIPPLE SECURED

INTO DECORATIVE ARM
FOR FIXTURE MOUNT. PLEASE CONFIRM.

K828 FIXTURE

SECTION VIEW

2.375" 1.5" 5"

BRACKET

0.5"Ø
HOLE

DRILL/TAP POLE FOR
3/8-16 HEX HEAD BOLT 6" 1.5" 1.5" 3" 2.375"
.188" FORMED

ALUMINUM BRACKET
3/16
GENERAL NOTES: 1. THIS DETAIL IS TO ILLUSTRATE THE GENERAL INTENT OF THE LIGHT ASSEMBLY SPECIFICATIONS AND FOR BIDDING PURPOSES ONLY

2. CONTRACTOR SHALL COORDINATE WITH THE ENGINEER AND LIGHT MANUFACTURER SALES REPRESENTATIVE FOR INFORMATION ON LIGHT FIXTURE, POLE, ANCHORING TEMPLATE, FOOTING, ETC. PRIOR TO SUBMITTING CUT-SHEET TO ENGINEER FOR REVIEW AND APPROVAL 6"

CONCRETE PEDESTAL

FINISHING SPECIFICATIONS
8" O.D. SMOOTH
EXTRUDED TUBE, 6061 ALLOY, 0.1875" WALL THICKNESS
** NOTE: SOUTH COAST LIGHTING DECORATIVE BASE COVERS DESIGNED TO BE INSTALLED SO THAT BOTTOM OF DECORATIVE BASE IS LEVEL WITH BOTTOM OF POLE BASE PLATE; CONTRACTOR

RESPONSIBLE FOR PROPER INSTALLATION & GROUTING BETWEEN
BOTTOM OF BASE COVER & FINISH GRADE**

SOUTH COAST LIGHTING & DESIGN
1101 VIA CALLEJON, STE. 100, SAN CLEMENTE, CA. 92673 VOICE - 949.276.8850 / FAX - 949.276.8855 [email protected] / WWW.SOUTHCOASTLIGHTING.COM

DUE TO CONTINUING IMPROVEMENTS, SOUTH COAST LIGHTING & DESIGN, INC RESERVES THE RIGHT TO CHANGE DIMENSIONS, DESIGNS, AND CONSTRUCTION FROM THAT WHICH IS SHOWN IN THIS BROCHURE. CONTACT FACTORY FOR DETAILED ENGINEERING DRAWINGS REV. REVISION NOTE DATE RVS'D BY
Lighting & Design South Coast
PROJECT NAME: CUDAHY PARK RENOVATION
J-050624-2S 1 OF 1
CUSTOMER: C.O. CUDAHY
DRAWN BY: J.G. CATALOG #: K90-26_FA-KA18_K828 5.06.24
DRAWING NUMBER:

DATE:

SHEET:

SALES: PRODUCTION: FINAL:
- - - -

WALKING PATH,

PLAYGROUND, SPLASH PAD

AND OUTDOOR FITNESS

Page 1179 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1150 of 1214 LIGHTING MANUFACTURER'S CONTACT:

AUDRA MASSEY

PERFORMANCE LIGHTING SYSTEMS
CELL: 951-741-8519
EMAIL: [email protected]

BASKETBALL, TENNIS &

PICKLEBALL COURTS AND

SKATEPARK

Page 1180 of 1692 ends

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1151 of 1214 APPENDIX 9.0

CONSTRUCTION DRAWINGS

Page 1181 of 1692 ends

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201

COVER SHEET

CITY OF CUDAHY
CITY PROJECT NUMBER : PRE-001

CONSTRUCTION PLANS
FOR

CUDAHY PARK RENOVATION PROJECT
PHASE 1
AT
5220 SANTA ANA STREET

CUDAHY, CALIFORNIA

1. ALL WORK SHALL CONFORM TO THE APWA "GREENBOOK" STANDARD PLANS AND SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION, LATEST EDITION, INCLUDING SUPPLEMENTS.

2. WORK IN PUBLIC STREETS, ONCE BEGUN, SHALL BE COMPLETED WITHOUT DELAY SO AS TO PROVIDE MINIMUM INCONVENIENCE TO ADJACENT PROPERTY OWNERS AND TO THE TRAVELING PUBLIC.

3. THE CONTRACTOR SHALL TAKE ALL NECESSARY AND PROPER PRECAUTIONS TO PROTECT ADJACENT

PROPERTIES FROM ANY AND ALL DAMAGE THAT MAY OCCUR FROM STORM WATER RUNOFF AND/OR DEPOSITION OF DEBRIS RESULTING FROM ANY AND ALL WORK IN CONNECTION WITH CONSTRUCTION ACTIVITIES.

4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CLEARING OF THE PROPOSED WORK AREA, AND RELOCATION COSTS OF ALL EXISTING UTILITIES. CONTRACTOR MUST INFORM CITY OF CONSTRUCTION SCHEDULE AT LEAST TWO WEEKS PRIOR TO BEGINNING OF CONSTRUCTION.

5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO APPLY TO THE CITY ENGINEER'S OFFICE, PERMIT

SECTION, PRIOR TO CONSTRUCTION FOR AN ENCROACHMENT PERMIT FOR ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY.

6. NO TRENCHES MAY BE LEFT OPEN OVERNIGHT UNLESS APPROVED BY CITY ENGINEER.

7. IF ANY UTILITIES OR FACILITIES CONFLICT WITH PROPOSED IMPROVEMENTS, ALL WORK SHALL STOP, AND THE CITY ENGINEER SHALL BE NOTIFIED IMMEDIATELY.

8. ALL TRAFFIC CONTROL DEVICES AND SIGNS SHALL BE IN PLACE PRIOR TO CONSTRUCTION.

9. DRIVEWAY LOCATION INFORMATION IS TO BE FIELD VERIFIED AND APPROVED BY CITY ENGINEER.

10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL SUBSTRUCTURES WITHIN THE LIMITS OF

WORK OF THE PROPOSED IMPROVEMENTS, AND IN THE EVENT OF SUBSTRUCTURE DAMAGE, HE SHALL BEAR THE TOTAL COST OF REPAIR OR REPLACEMENT AT NO ADDITIONAL COST TO THE CITY.

11. THE CONTRACTOR SHALL NOT CONDUCT ANY OPERATIONS OR PERFORM ANY WORK PERTAINING TO THE PROJECT BETWEEN 9:00 P.M. AND 5:00 A.M. ON ANY DAY NOR ON SATURDAYS, SUNDAYS (EXCEPT AT NIGHT) OR HOLIDAYS, AT ANY TIME EXCEPT AS APPROVED BY THE CITY ENGINEER.

12. UNLESS OTHERWISE AS INDICATED ON THE PLANS, ALL EXISTING TREES, FOLIAGE, SIGNS, AND OTHER PARK

FEATURES SHALL BE PROTECTED IN PLACE AND ANY DAMAGE TO EXISTING IMPROVEMENTS SHALL BE REPLACED IN KIND AT NO ADDITIONAL COST TO THE CITY.

13. THE CONTRACTOR IS ADVISED THAT ALL EXCAVATED MATERIALS SHALL BECOME HIS PROPERTY AND SHALL BE REMOVED FROM THE JOB-SITE UNLESS INSTRUCTED BY THE CITY ENGINEER TO DO OTHERWISE.

14. THE CONTRACTOR SHALL BE RESPONSIBLE DURING ALL PHASES OF THE WORK TO PROVIDE FOR PUBLIC SAFETY AND CONVENIENCE.

15. THE CONTRACTOR SHALL RELOCATE/ADJUST EXISTING UTILITY BOXES, VALVES, AND VAULTS TO GRADE AND THE COSTS ARE TO BE DISTRIBUTED AMONG VARIOUS ITEMS ON THE BID SCHEDULE.

16. THE CONTRACTOR SHALL PROVIDE A TRAFFIC CONTROL PLAN FOR THE COMPLETION OF THE PROPOSED

IMPROVEMENTS PER THE CURRENT CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (CA MUTCD), SPECIAL PROVISIONS, AND TO THE SATISFACTION OF THE CITY ENGINEER. THE CONTRACTOR WILL BE ALLOWED

TO CLOSE LANES WITHIN THE PROJECT AREA ONLY WITHIN THE HOURS STATED IN THE PROJECTS SPECIAL PROVISIONS.

17. THE CONTRACTOR SHALL PROVIDE A 72-HOUR NOTIFICATION TO THE AFFECTED PROPERTIES, POLICE

DEPARTMENT, AND FIRE DEPARTMENT IN THE EVENT OF A CHANGE IN STREET CLOSURE TO TRAFFIC AND/OR

PUBLIC SAFETY VEHICLES, PARKING RESTRICTIONS, AND ON EACH MONDAY MORNING DURING THE CONSTRUCTION PERIOD.

18. ALL PORTLAND CEMENT CONCRETE (P.C.C.) AND ASPHALTIC CONCRETE (A.C.) SHALL BE REMOVED TO A SAWCUT AND/OR EXISTING CONTROL JOINTS.

19. CONTRACTOR SHALL IMPLEMENT DUST CONTROL MEASURES AT ALL TIMES.

20. RECORD DRAWINGS OF THE COMPLETED PROJECT SHALL BE SUBMITTED FOR APPROVAL BY THE CITY ENGINEER.

21. CONTRACTOR SHALL NOTIFY ALL AFFECTED BUSINESSES IN WRITING AT LEAST TWO (2) FULL WORKING DAYS BEFORE THE START OF ANY CONSTRUCTION AS SPECIFIED.

22. CONTRACTOR SHALL CONTACT UNDERGROUND SERVICE ALERT (DIG ALERT) AT 811 TWO (2) FULL WORKING DAYS PRIOR TO START OF WORK. CONTRACTOR MUST OBTAIN AND MAINTAIN VALID DIG ALERT REFERENCE NUMBER THROUGH THE DURATION OF THE PROJECT AS NECESSARY FOR CONSTRUCTION. UPON EXPOSING ANY UTILITY'S UNDERGROUND FACILITY THE CONTRACTOR SHALL NOTIFY THAT UTILITY IMMEDIATELY.

19. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MAY OCCURRED DUE TO THE FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.

20. IF REQUIRED, CONTRACTOR SHALL PREPARE A WET WEATHER EROSION CONTROL PLAN DELINEATING BMPS TO

BE INSTALLED PER NPDES, SWPPP, SUSMP, AND LID LOCAL, STATE, AND FEDERAL REGULATIONS TO BE APPROVED BY THE CITY ENGINEER PRIOR TO THE START OF CONSTRUCTION.

21. CONTRACTOR SHALL PROVIDE CONSTRUCTION SURVEY IF IT IS DEEMED NECESSARY AND BEAR ALL COSTS.

1. APPROVAL OF THESE PLANS BY THE CITY OF CUDAHY DOES NOT CONSTITUTE A

REPRESENTATION AS TO THE ACCURACY OR COMPLETENESS OF THE LOCATION OR THE

EXISTENCE OR NONEXISTENCE OF ANY UNDERGROUND UTILITY OR SUBSTRUCTURE WITHIN THE LIMITS OF THE PROJECT.

2. THE CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY

ACCEPTED CONSTRUCTION PRACTICES, THE CONSTRUCTION CONTRACTOR WILL BE

REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS

DURING THE COURSE OF CONSTRUCTION FOR THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL BE MADE TO APPLY

CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AND THE

CONSTRUCTION CONTRACTOR FURTHER AGREES TO DEFEND, INDEMNIFY AND HOLD THE

DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN

CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF THE DESIGN PROFESSIONAL.

THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE

RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF

CONSTRUCTION OF THE PROJECT INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL

DEFEND, INDEMNIFY, AND HOLD THE CITY OF CUDAHY AND THE PRIVATE ENGINEERS HARMLESS FOR ANY AND ALL LIABILITY; REAL OR ALLEGED, IN CONNECTIONS WITH PERFORMANCE OF WORK ON THIS PROJECT. OFF-SITE

DISPOSAL OF CONSTRUCTION DEBRIS, LANDSCAPE AND IRRIGATION MATERIAL,

AND SOIL EXCAVATION MATERIAL IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE INCLUDED IN HIS BID. THE CONTRACTOR SHALL HOLD THE CITY AND

ENGINEER HARMLESS AS A RESULT OF ANY CLAIMS ARISING FROM ACTIONS EN-ROUTE TO OR AWAY FROM THE SITE.

UTILITY AND STRUCTURE NOTICE TO CONTRACTOR:

THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITIES OR ON GRADE

STRUCTURES SHOWN ON THESE PLANS WERE OBTAINED BY A SEARCH OF AVAILABLE RECORDS. THESE LOCATIONS ARE APPROXIMATE AND SHALL BE

CONFIRMED IN THE FIELD BY THE CONTRACTOR, SO THAT ANY NECESSARY

ADJUSTMENT CAN BE MADE IN ALIGNMENT AND/OR GRADE OF THE PROPOSED IMPROVEMENT. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY

MEASURES TO PROTECT ANY UTILITY LINES SHOWN AND ANY OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE PLANS. THE CITY AND ENGINEER ASSUME NO

LIABILITY AS TO THE EXACT LOCATION OF SAID LINES, UTILITIES, STRUCTURES,

SANITARY SEWER AND WATER SUPPLY LINES WHOSE LOCATION ARE SHOWN OR NOT SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING ALL

UTILITY AND WATER PURVEYOR COMPANIES PRIOR TO WORK OR EXCAVATION TO

DETERMINE THE EXACT LOCATION OF ALL UTILITIES, STRUCTURES, AND LINES

AFFECTING THIS WORK, WHETHER OR NOT SHOWN HEREON, AND FOR ANY DAMAGE OCCURRED TO THESE LINES.

GENERAL NOTES:

HOLD HARMLESS INDEMNIFICATION CLAUSE:

CITY OF SOUTH GATE

CITY OF BELL

CITY OF

HUNTINGTON PARK

VICINITY MAP

PROJECT LOCATION LOS ANGELES RIVER
SHEET NO. PLAN NO. DESCRIPTION
37 E4.1 SINGLE LINE DIAGRAM
38 E4.2 PANEL AND FIXTURE SCHEDULES
39 SK1.0 SKATEPARK 3D PERSPECTIVE
40 SK1.1 SKATEPARK 3D PERSPECTIVE
41 SK2.0 SKATEPARK SPECIFICATIONS
42 SK2.1 SKATEPARK SPECIFICATIONS
43 SK3.0 SKATEPARK SITE PLAN
44 SK3.1 SKATEPARK INFORMATION PLAN
45 SK4.0 SKATEPARK PAVING COLOR PLAN
46 SK5.0 SKATEPARK LAYOUT PLAN
47 SK6.0 SKATEPARK GRADING AND DRAINAGE PLAN
48 SK7.0 SKATEPARK STEEL PLAN
49 SK8.0 SKATEPARK SECTIONS
50 SK8.1 SKATEPARK SECTIONS
51 SK9.0 SKATEPARK CONSTRUCTION DETAILS
52 SK9.1 SKATEPARK CONSTRUCTION DETAILS
53-55 SP-1 TO SP-3 SPLASH PAD SITE PLAN
56 GP-1 SPLASH PAD GENERAL GRADING/DRAINAGE
PLAN
57 DP-1 SPLASH PAD FEATURES AND EQUIPMENT

LAYOUT PLAN
58 DP-2 SPLASH PAD FEATURES PLUMBING/PIPING

DIAGRAM AND SUMP DRAIN DETAIL
59 DP-3 EQUIPMENT ENCLOSURE LAYOUT AND

EQUIPMENT DETAILS
60 DP-4 SPLASH PAD EQUIPMENT SCHEDULES

AND ELECTRICAL PANEL SCHEMATIC
61 DP-5 OUTDOOR SHOWER LAYOUT PLAN AND WATER

SUPPLY CONNECTION SCHEMATIC
62 AP-1 EXISTING RESTROOM FLOOR PLAN
- FOR REFERENCE ONLY
63 CN-1 CONTRACTOR NOTES
CONTRACTOR GENERAL NOTES: SCOPE OF WORK - PHASE 1 SHEET INDEX CS-1
SHEET NO. PLAN NO. DESCRIPTION
1 CS-1 COVER SHEET
2-3 D-1 TO D-2 DEMOLITION PLAN
4-5 EC-1 TO EC-2 EROSION CONTROL PLAN
6-7 C-1 TO C-2 CONSTRUCTION PLAN
8-9 G-1 TO G-2 GRADING AND DRAINAGE PLAN
10 H-1 HORIZONTAL CONTROL PLAN
11-12 H2 TO H3 LINE AND CURVE DATA TABLE
13 CD-1 PAVING DETAILS
14 CD-2 FENCE, GATE AND WALL DETAILS
15 CD-3 BASKETBALL, PICKLEBALL, TENNIS COURT AND

OUTDOOR FITNESS DETAILS
16 CD-4 SITE AMENITIES AND FURNITURE DETAILS
17 CD-5 PREFABRICATED PICNIC SHADE STRUCTURE
18 CD-6 PREFABRICATED PICNIC SHADE STRUCTURE AND

LAYOUTS
19 CD-7 PLAYGROUND EQUIPMENT AND SURFACING
20 IP-1 IRRIGATION MODIFICATION PLAN
21 IP-2 IRRIGATION LEGEND AND NOTES
22 IP-3 IRRIGATION AS-BUILT
23 IP-4 IRRIGATION WATERING SCHEDULE
24 ID-1 IRRIGATION DETAILS
25 PP-1 PLANTING PLAN
26 PD-1 PLANTING DETAILS
27 E0.1 PROJECT NOTES, SYMBOLS AND SHEET INDEX
28 E0.2 ELECTRICAL SPECIFICATIONS
29 E0.3 TITLE 24 OUTDOOR COMPLIANCE FORMS
30 E0.4 TITLE 24 OUTDOOR COMPLIANCE FORMS
31 E1.0 PARK DEMOLITION ELECTRICAL SITE PLAN
32 E1.1 OVERALL ELECTRICAL SITE PLAN
33 E2.1 ELECTRICAL SITE PLAN - WEST
34 E3.1 PARK WALKWAY PHOTOMETRIC PLAN
35 E3.2 BASKETBALL AND TENNIS COURT PHOTOMETRIC

PLAN & POLE DETAIL
36 E3.3 BASKETBALL AND TENNIS COURT LIGHTING

PHOTOMETRY & INSTALLATION DETAIL

THE CUDAHY PARK RENOVATION PROJECT FOCUSES ON PARKWIDE RENOVATION

IMPROVEMENTS OF THE SPLASH PAD, OUTDOOR SHOWER, BASKETBALL, TENNIS

COURT, PICKLEBALL, PLAYGROUND, SKATEPARK, AND HOT WATER HEATER IN STORAGE ROOM. ADDITIONS TO THE PARK INCLUDE WALKWAY REPLACEMENT, EXERCISE EQUIPMENT, PICNIC AREAS, SITE FURNITURE, SHADE STRUCTURES, AND PARK LIGHTING SYSTEM.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1152 of 1214

RAUL DIAZ

PUBLIC WORKS DIRECTOR

Page 1182 of 1692 ends

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
P PHASE 2 (N.I.C.)

MATCH LINE
SEE PLAN NO. D-2

BUILDING

RESTROOM
D-1
G
G
G
G
B
P
C
P R
R
P
P
P
P
P
P
R
R
P
G
P
P
A
A
B
R
P
P
I
G
P
P
R
R
P
R
R
R
R
R P
R
P
R
P
P
P
P
P

DEMOLITION GENERAL NOTES DEMOLITION CODE COMPLIANCY
A
P
E
D
D
D
B
E
F
B
I
P
G
P
R
A
B
C
D
F
E
G
P
H

LEGEND DEMOLITION/REMOVAL NOTES
R
I
J
K
L
RT

DEMOLITION PLAN
L
L
L
L
L
L
P
R
P
P
RT
RT
RT

BEDWEL HALL

RESTROOM

TREE PROTECTION NOTES
·
·
·
·

CITY HALL
D

PROJECT LIMIT

PROJECT LIMIT
R
P
P
PORT
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1153 of 1214 I

BACKFILL NOTE

Page 1183 of 1692 ends

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201

MATCH LINE
SEE PLAN NO D-1.

D-2
P
P
P

S A N T A A N A S T
P P
P
P
P
P
P
SEE PLAN NO. D-1 FOR COMPLETE DEMOLITION NOTES

DEMOLITION PLAN
P

DEMOLITION/REMOVAL NOTES

CITY HALL

BEDWEL HALL
D

PARKING LOT
D

P PROJECT LIMIT

PROJECT LIMIT
R
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1154 of 1214 Page 1184 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
EC-1

LEGEND EROSION CONSTRUCTION NOTES R I V E R R D

CECILIA S T

EROSION CONTROL PLAN
SEE PLAN NO. EC-2 FOR DETAILS AND GENERAL NOTES
SEE PLAN NO. D-1 FOR TREE PROTECTION NOTES

PLAYGROUND

SKATEPARK

BASKETBALL ,

PICKLEBALL &

TENNIS COURT

FITNESS
AREA
SPLASH
PAD

RESTROOMS

CITY HALL

BEDWELL HALL

COMMUNITY
STAGE

BASEBALL FIELD

T-MOBILE

CELL TOWER
FUTURE

STORAGE

BUILDING

SOIL MITIGATION ZONE

REQUIRED SOIL LIMIT DISTURBANCE SOIL MITIGATION ZONE REQUIRED SOIL LIMIT DISTURBANCE

SOIL MITIGATION ZONE AREA
PHASE 1
PHASE 2
PHASE 2
PHASE 2
PHASE 1

PROJECT LIMIT
PHASE 2
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1155 of 1214 Page 1185 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201

EROSION CONTROL NOTES
EC-2

DETAIL B

STORM DRAIN INLET PROTECTION
(WHERE APPLICABLE)
N.T.S.

N.T.S.

STABILIZED CONSTRUCTION ENTRANCE/EXIT

DETAIL D

CONCRETE WASTE MANAGEMENT AREA

SECTION B-B

DETAIL G

TYPICAL SECTION A-A
(WHERE APPLICABLE)

DETAIL E

FILTER FABRIC DETAIL
(WHERE APPLICABLE)
N.T.S.

N.T.S. N.T.S.

N.T.S.

DETAIL F

TYPICAL SECTION

EROSION CONTROL PLAN

LEGEND EROSION CONSTRUCTION NOTES
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1156 of 1214 Page 1186 of 1692 V01 V15 V10 V24
V12 V11 W009 #3
V02 WMM-600 V03 V09 V22 V04 V13 V03 V04 V07 WMM-600 V20 V08 W009 #1 V06 V14 V19 V18 V07 V06 V08 V17 V05 W009 #2 V08 WMM-600 V19
V21 V21 V23
V16 V05 1186-ADA-2 Option Top View

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
C-1

CONSTRUCTION PLAN
·
·
·
·
·
·

CONSTRUCTION GENERAL NOTES
22 22
5 5
10 22
6 6
6 6
6 6
16 16
10 13
13 13
1 1
1 1
1 1
9 10
1 24
9 8
11 13
1 17
3 18
20 20
22 22
22 1
1 7B
7B
7B
14 9
9 25
25 26
5 7B
7A
25 2
2 25
1 3
4 5
6 7A
8 9

CONSTRUCTION NOTES
2 14
10 11
12 13
15 16
17 18
20 21
22 19
23 24
25 7B
26 7C
7B
7B
7A
7B
1 1
1 1
1 7C
7C
7C
7C
28 RESTROOMS

CITY HALL

BEDWELL HALL
8 8
8 8
8 8
16 16
16 16
16 16
16 16
16 16
16 16
16 27
11 2

PROJECT LIMIT

MATCH LINE
SEE PLAN NO. C-2
28 28
28 28 PHASE 2 (N.I.C.)

PROJECT LIMIT
8 15
15 6
6 6
8 SCHEDULE OF MATERIAL
1 2
3 4
5 7A
7B
22 22
22 8
9 10
11 13
15 16
17 25
26 27
28 SEE PLAN NO. C-2 FOR CONSTRUCTION

INFORMATION SIGN
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
16 12
12 12
12 12
12 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1157 of 1214 Page 1187 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
C-2

MATCH LINE
SEE PLAN NO C-1.

S A N T A A N A S T

CITY HALL

BEDWEL HALL

PARKING LOT
23 23
28 CONSTRUCTION NOTES PROJECT LIMIT

PROJECT LIMIT

CONSTRUCTION PLAN
28 SCHEDULE OF MATERIAL
28 CONSTRUCTION INFORMATION SIGN
NTS
NOTES
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1158 of 1214 Page 1188 of 1692 SEE PLAN NO. GP-1 FOR GRADING

INFORMATION

OUTDOOR
FITNESS 1186-ADA-2 Option Top View
1186-ADA-2 Option Top View
SEE STAKEPARK GRADING + DRAINAGE
PLAN FOR GRADING INFO. INSIDE

SKATEPARK
SEE PLAN NO. CD-10 FOR PLAYGROUND

GRADING INFORMATION BENEATH THE

RUBBERIZED SURFACING

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
G-1

GRADING AND DRAINAGE PLAN

GRADING GENERAL NOTES GRADING KEY

STORAGE

BUILDING

RESTROOMS

CITY HALL BEDWELL HALL

PLAYGROUND

SPLASH PAD
SKATEPARK PHASE 2 (N.I.C.)

PROJECT LIMIT

MATCH LINE
SEE PLAN NO. G-2

BASKETBALL,

PICKLEBALL &

TENNIS COURTS
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1159 of 1214 Page 1189 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
G-2

MATCH LINE
SEE PLAN NO G-1.

S A N T A A N A S T

CITY HALL

BEDWEL HALL

PARKING LOT

GRADING KEY PROJECT LIMIT

PROJECT LIMIT

GRADING AND DRAINAGE PLAN
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1160 of 1214 Page 1190 of 1692 1186-ADA-2 Option Top View

SPLASH PAD

W/SHADE STRUCTURES
SEE PLAN NO. SP-1 TO CN-1 FOR

EQUIPMENT LAYOUTS AND DETAILS

PLAYGROUND
SEE DETAIL 1, PLAN NO. CD-10 FOR

EQUIPMENT LAYOUT AND DETAILS

OUTDOOR

FITNESS

TENNIS/PICKLEBALL
SEE DETAIL 1, PLAN NO.

CD-3 FOR EQUIPMENT

LAYOUT AND DETAILS

BASKETBALL/PICKLEBALL
SEE DETAIL 1, PLAN NO.

CD-3 FOR EQUIPMENT

LAYOUT AND DETAILS

SKATEPARK
SEE PLAN NO. SK1 TO SK9.1 FOR

SKATEPARK FEATURES LAYOUT,

CONSTRICTION DETAILS
FUTRE

STORAGE

BUILDING
SEE DETAIL 2, PLAN NO.

CD-3 FOR EQUIPMENT

LAYOUT AND DETAILS

WATER DISPLAY
SEE DETAILS, PLAN NO.

CD-12 FOR EQUIPMENT

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
H-1

HORIZONTAL CONTROL PLAN
SEE PLAN NO. H-2 & H-3 FOR LINE AND CURVE DATA TABLE
NOTES

RESTROOMS

CITY HALL

BEDWELL HALL
PROJECT LIMIT PHASE 2 (N.I.C.)

PROJECT LIMIT
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1161 of 1214 Page 1191 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
H-2

LINE AND CURVE DATA TABLE

SEE CONTINUATION OF LINE AND CURVE
DATA TABLE ON PLAN NO. H-3
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1162 of 1214 Page 1192 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
H-3

LINE AND CURVE DATA TABLE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1163 of 1214 Page 1193 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
CD-1

PAVING DETAILS
1 PCC WALKWAY AND GENERAL PCC PAVING

GENERAL NOTES
NTS
·
·
·
·
·
1 2
3 4
5 6

GENERAL NOTES

TOOLED JOINT

EXPANSION JOINT
3 2 1
1 5
6 COLD JOINT
3 1
4 4 2
4 2
2 JOINT(S) NTS
3 NTS

NTS NTS
1 2
3 4
5 6
7 8
9 10
1 2
3 4
5 11
11 7
8 9 8
9 8 9
10 3
4 9

TYPICAL SECTION
6-INCH PCC SLAB AT CENTER COURT OR GRADE BREAK

TYPICAL SECTION
6-INCH PCC SLAB MEETS 4-INCH PCC PAVING/SIDEWALK

GENERAL NOTES
12 6
6 12
11 12
1 PCC BASKETBALL COURT, TENNIS COURT, AND ELECTRICAL PAD AT

TRANSFORMER/ SWITCHBOARD
1 2
3 4
5 GENERAL NOTES

GRAVEL AREA
3 1
2 5
4 5

PCC CURB
1 2
3 4
5 6
7 1
2 1
3 2
3 8
4 4
5 6
6 8 7
6" PCC CURB AROUND

BIO-INFILTRATION BASIN AND

WATER FEATURE VAULT
9" PCC CURB UNDER TUBULAR

ALUMINUM FENCE
NTS
4 6 RESERVED

DAYTON SUPERIOR TOP-CAST SURFACE RETARDANT AND DAVIS COLORS Cudahy Park Renovation Project, Project # PRE-001 Document Control 1164 of 1214 Page 1194 of 1692 5 2 3
9 10
8 7
6 1
11 11
1 4
6 7
10 2
2 11
6 9

CONSTRUCTION NOTES
1 2
4 5
6 3
NOTES
7 8
9 10
11 CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
5220 SANTA ANA ST, CUDAHY, CA 90201
CD-2

FENCE, GATE AND WALL DETAILS
1 8FT HI CMU WALL FOR ART MURAL NTS

CUDAHY PARK PRIVATE

PROPERTY
NOTES:
1 2
3 4
5 6
7 2
1 3
4 5
6 7

FORERUNNER TM
TYPICAL FENCE & GATE @

ELECTRICAL EQUIPMENT AND SPLASH PAD

EQUIPMENT ENCLOSURE

FENCE PANEL SINGLE SWING GATE

FENCE PANEL

FORERUNNER
TM

SINGLE SWING GATE

DOUBLE SWING GATE
TYPICAL FENCE @

OUTDOOR FITNESS, SPLASH

PAD AND SKATEPARK
SINGLE SWING GATE @

OUTDOOR FITNESS AND SPLASH PAD
DOUBLE SWING GATE @

SKATEPARK
·
··
·
GENERAL NOTES:

FENCE & GATE @

ELECTRICAL EQUIPMENT
(TRANSFORMER & SWITCHGEAR)
NTS
FENCE & GATE @

ELECTRICAL EQUIPMENT
(ELECTRICAL SUB-PANEL AND

SPORT FIELD LIGHT CONTROLLER)
NTS

WALL LAYOUT PLAN
(ART MURAL)
NTS
3 PREFABRICATED ALUMINUM FENCE & GATE
GATE STOP POST @

OPENING POSITION
(SEE CONSTRUCTION PLAN FOR LOCATIONS)
FENCE

CONNECTION TO

MASONRY WALL
NTS
NTS
2 BASKETBALL AND TENNIS COURT CHAIN LINK FENCE AND GATE

TYPICAL ELEVATION
(ART MURAL)
NTS

WALL LAYOUT PLAN
(EQUIPMENT ENCLOSURE)
NTS

TYPICAL ELEVATION
(EQUIPMENT ENCLOSURE)
NTS
GATE

INSTALLATION

ADJACENT TO

MASONRY WALL

TYPICAL SECTIONAL ELEVATION
(ART MURAL)
NTS
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1165 of 1214 Page 1195 of 1692 A B
A B
A B
D
C C
E
E
A B
A B
A B
D
D
F
A
B
A
B
C
C
C
C
C
B

CONSTRUCTION NOTES COURT SLAB

SURFACING COLOR
A
B
C
D
E
F

CONSTRUCTION NOTES
A
B
C
D

GENERAL NOTE

SPORT EQUIPMENT/APPARATUS

GENERAL NOTES

2. SHADE STRUCTURE SHOWN IS FOR ILLUSTRATION ONLY. SHADE STRUCTURE SHALL BE EXCLUDED FROM THE CONTRACT.

GENERAL NOTES

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
CD-3

BASKETBALL, PICKLEBALL, TENNIS COURT AND

OUTDOOR FITNESS EQUIPMENT
2 NTS
1 NTS

PLAN VIEW
5 1
4 1
3 SECTIONAL FRONT VIEW SECTIONAL SIDE VIEW
2 TENNIS, PICKLEBALL AND BASKETBALL COURTS

BASKETBALL/TENNIS COURT, OUTDOOR FITNESS EQUIPMENT AND DECOMPOSED GRANITE PAVING 6 FOOTING AND

REINFORCEMENT
NOTES

TENNIS COURT NET POST & SLEEVE

FOOTING AND REINFORCEMENT NOTES
1 2
3 4
5 6
8 8

BASKETBALL & TENNIS STRIPING LAYOUT
NTS

TYPICAL PICKLEBALL

STRIPING LAYOUT
NTS

COURT SLAB SURFACING COLOR LAYOUT
NTS
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1166 of 1214 Page 1196 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
CD-4

SITE AMENITIES AND FURNITURE DETAILS
1 NTS 2

GENERAL NOTES
4 PREFABRICATED DRINKING FOUNTAIN NTS
1 CLEAN OUT SECTION

SECTION
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
5 16
4 8
7 8
9 4
1 12
3 12
15 11
13 10
14 4 17
12 3
8 18
6 11
GENERAL NOTES:
2 SAND TRAP/SUMP DRAIN

SHUT-OFF VALVE
PLAN
2 GENERAL NOTES

PRECAST CONCRETE PARK BENCH

REST AREA TYPICAL LAYOUT

OUTDOOR GRILL AND COAL BIN

PRECAST CONCRETE TRASH RECEPTACLE AND PICNIC TABLE NTS

GENERAL NOTES
3 NTS
16 11

STAINLESS STEEL SURFACE CARRIER REQUIRED
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1167 of 1214 Page 1197 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
PREFABRICATED PICNIC SHADE STRUCTURE NTS CD-5

GENERAL NOTE

PREFABRICATED PICNIC SHADE STRUCTURE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1168 of 1214 Page 1198 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
CD-9

PREFABRICATED PICNIC SHADE STRUCTURE

AND LAYOUTS
1 PREFABRICATED PICNIC SHADE STRUCTURE

TYPICAL PICNIC SHADE STRUCTURE AND

CONCRETE PAD LAYOUT
1"=4'-0"

TYPICAL PICNIC TABLE LAYOUT
1"=2'-0"

GENERAL NOTE
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1169 of 1214 Page 1199 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
5220 SANTA ANA ST, CUDAHY, CA 90201
CD-10

PLAYGROUND EQUIPMENT AND SURFACING
1 PLAYGROUND EQUIPMENT AND SURFACING NTS

PLAYGROUND STRUCTURE

GENERAL NOTES

PLAYGROUND GENERAL GRADING PLAN
SCALE: 1"=10'

PLAYGROUND GENERAL LAYOUT PLAN
SCALE: 1"=10'

RUBBERIZED SURFACING COLOR SCHEME
SCALE: 1"=20'
NOTES
3 3
4 1
2 4
5 7
6 3
1 TYPICAL CROSS SECTION

SUMP DRAIN
8 9
4 ·
· ” ” ” ·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
· ” ” ·
·
·
·
·
·
·
·
·
·
·
·

PLAYGROUND EQUIPMENT LIST
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
· ” ” ” ” ” ”
” ” · ” ” ” ” · ” ” ” ” ” ·
·
·
·
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1170 of 1214 Page 1200 of 1692 1186-ADA-2 Option Top View
X
X
X
1"
A-4 1
RZWS
A-10 25
1-1
2 " ROTARY
A-13 45
2" ROTARY
A-37 28
1-1
2 " ROTARY
A-24 31
1-1
2 " ROTOR
A
A-5 30
1-1
2 " ROTARY
1"
A-15 6
RZWS
A-35 28
1-1
2 " ROTARY
A-32 45
2" ROTARY
1"
A-11 9
ROTARY
B
1"
A-36 2
ROTARY 1"
A-34 2
RZWS
A-33 16
1-1
2 " ROTARY
x

SYM DESCRIPTION

IRRIGATION LEGEND
IRRIGATION DESIGN CRITERIA - POC:

G.P.M. DEMAND PIPE SIZE TYPE
PIPING SIZES:
1"
A-6 8
ROTARY
1"
A-7 16
ROTARY
1"
A-8 9
ROTARY
1"
A-9 19
ROTARY
1"
A-23 7
RWS
A-16 21
1-1
2 " ROTOR
A-4
A-5
A-6
A-7
A-8
A-9
A-10
A-11
A-12
A-13 A-14 A-15 A-16
A-21
A-22
A-23
A-24
A-25
A-26
A-27
A-28
A-29
A-30
A-31
A-32
A-35 A-34 A-33
A-36
A-37
A-12 22
1-1
2 " ROTARY
1"
A-14 14
ROTOR

IRRIGATION CONSTRUCTION NOTES
·
·
·
·
·
·
·
·
·
·
1 2
3 4
SOIL MANAGEMENT REPORT (SECTION 492.5)*
·
·
·
·
·
·
·
·
·
·
5 6
7N
7S
8 WL
PS
x

SYM DESCRIPTION

IRRIGATION LEGEND
IRRIGATION DESIGN CRITERIA - POC:

G.P.M. DEMAND PIPE SIZE TYPE
PIPING SIZES:

THE IRRIGATION SYSTEM DESIGN SHOWN IS
DIAGRAMMATIC. ALL PIPING, VALVES, CONTROLLERS,
EQUIPMENT AND ETC. SHOWN WITHIN PAVED AREAS
ARE FOR DESIGN CLARIFICATION ONLY. ALL PIPES,
SLEEVES, CONDUITS, VALVES, ETC. SHALL BE

INSTALLED IN PLANTING AREAS WHEREVER
POSSIBLE.

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
IP-1

IRRIGATION MODIFICATION PLAN
2 3
8 4
7N
EX. METER:

FIELD VERIFY METER
SIZE
BF: 2"
P.O.C. # 1

ELECTRICAL
ROOM
7S 8

NORTHERN CITY HALL

SECTION
5 WL
WL
1 SEE IRRIGATION LEGEND AND NOTES ON PLAN NO. IP-2 AND
IRRIGATION WATERING SCHEDULE ON PLAN NO. IP-4
WL
WL
WL
WL

CITY HALL

PLAYGROUND SPLASH PAD
REST
ROOMS

SKATE PARK

BEDWELL HALL

FITNESS AREA

BASKETBALL,

PICKLEBALL
&

TENNIS COURT

T-MOBILE

ANTENNA
FACILITY PHASE 2 (N.I.C.)
PS
PS
PS
PS
PS

PROJECT LIMIT

PROJECT LIMIT
PS
PS
PS
PS
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
PS
PS
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1171 of 1214 Page 1201 of 1692

IRRIGATION GENERAL NOTES

1. THE IRRIGATION SYSTEM DESIGN SHOWN IS
DIAGRAMMATIC. ALL PIPING, VALVES, CONTROLLERS,
EQUIPMENT AND ETC. SHOWN WITHIN PAVED AREAS
ARE FOR DESIGN CLARIFICATION ONLY. ALL PIPES,
SLEEVES, CONDUITS, VALVES, ETC. SHALL BE

INSTALLED IN PLANTING AREAS WHEREVER
POSSIBLE.

IRRIGATION DESIGN CRITERIA - POC:

IRRIGATION CONSTRUCTION NOTES
··
··
·
·
·
·
·
·
1 CONTROL VALVE INFORMATION
SYM DESCRIPTION MANF. BODY NOZ. PSI RAD GPM DET.

PROJECT INFORMATION (SECTION 492.3(1))*

LANDSCAPE AND IRRIGATION MAINTENANCE
SCHEDULE (SECTION 492.11)*
·
·
·
·
·
·
IRRIGATION AUDIT/IRRIGATION WATER USE ANALYSIS (SECTION 492.12)* SOIL MANAGEMENT REPORT (SECTION 492.5)*
·
·
·
·
·
·
* REFERENCE:

PLAN
WATER EFFICIENT LANDSCAPE WORKSHEET (SEC. 492.4)*

MAXIMUM APPLIED WATER ALLOWANCE (MAWA)
MAWA = 3,955,686

ESTIMATED TOTAL WATER USE (ETWU)
ETWU= 3,680,696 GALLONS
REFERENCE EVAPOTRANSPIRATION (ETo): 49.7

HYDROZONE PLANT
FACTOR*

IRRIGATION
METHOD**

IRRIGATION

EFFICIENCY
(IE)
ETAF
(PF/IE) AREA (S.F.) ETAF X AREA

ESTIMATED TOTAL

WATER USE
(ETWU)

NEW CONTROLLER A

SPECIAL LANDSCAPE AREAS (PARK SETTING USING RECYCLED WATER SOURCE)

ESTIMATED TOTAL WATER USE

MAXIMUM ANNUAL WATER ALLOWANCE

ETAF (SLA) ETAFXLA ETAFXSLA
·
·
·
·
·
·
·
·
·
·
2 3
4 5
x
SYM DESCRIPTION MANUF. MODEL REMARKS DET. PLAN

IRRIGATION LEGEND
1"
X-X X.X
6 7N
7S
8 G.P.M. DEMAND PIPE SIZE TYPE
PIPING SIZES:

WL
PS

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
IP-2

IRRIGATION LEGEND AND NOTES
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1172 of 1214 Page 1202 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
IP-3

IRRIGATION AS-BUILT
CIRCA 1967

FOR REFERENCE ONLY
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1173 of 1214 Page 1203 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201

IRRIGATION WATERING SCHEDULE
IP-4
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1174 of 1214 Page 1204 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
ID-1

IRRIGATION DETAILS
10 NTS
NOTES
1 MASTER VALVE AND FLOW SENSOR Y-STRAINER NTS
NOTES:

NOTE:

NTS 2 BACKFLOW PREVENTER NTS 3 NTS 4 GATE VALVE
5 POP-UP SPRAY ASSEMBLY NTS 6 POP-UP ROTOR ASSEMBLY NTS 7 RZWS NTS 8 REMOTE CONTROL VALVE NTS 9 TRENCHING IN PLANTING AREA AND UNDER PAVINGNTS R U.S. PAT. 2 1 1 , 2 4 2 , 5
R
R
NOTES:

NOTES:
·
11 QUICK COUPLER VALVE NTS 12 IRRIGATION CONTROLLER NTS 13 NTS NOTE:

WR2WIRELESS SENSOR
SENSOR NOTES:

PULL BOX
6 NOTE:

IRRIGATION PIPE STUB-OUT
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1175 of 1214 Page 1205 of 1692 1186-ADA-2 Option Top View
X
X
X
GENERAL NOTES:

BOTANICAL NAME COMMON NAME QTY. REMARKS DET.

PLANTING LEGEND
SIZE
TREES
SYM PLAN NO. WUCOLS

GROUNDCOVERS
SYM BOTANICAL NAME COMMON NAME SIZE QTY. REMARKS DET.

SHRUBS
HT.

SP. WUCOLS
PLAN
HT.

SP.

NO.

X

TREES, SHRUBS AND GROUNDCOVER PROCUREMENT

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
PP-1

PLANTING PLAN

PLAYGROUND

SKATEPARK

BASKETBALL,

PICKLEBALL &

TENNIS COURT

FITNESS
AREA
SPLASH
PAD

RESTROOMS

CITY HALL BEDWELL HALL

T-MOBILE
CELL TOWER PHASE 2
PROJECT LIMIT (N.I.C.)

PROJECT LIMIT
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
PHASE 2
(N.I.C.)
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1176 of 1214 Page 1206 of 1692

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
® PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
PD-1

PLANTING DETAILS
8 NTS
1 TREE PLANTING NTS 2 SHRUB PLANTING NTS 3 NTS
4 NTS 5 NTS 6 NTS
NOTE:

NOTE:
9 NTS 10 NTS 11 NTS

ROOT CONTROL BARRIER IN TREE WELL GROUNDCOVER PLANTING RESERVED

RESERVED RESERVED RESERVED RESERVED
PLAN
NOTES
2 1
3 1
2 3
NOTES:

TYPICAL GROUNDCOVER LAYOUT PLAN

RESERVED
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1177 of 1214 Page 1207 of 1692 CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what'sbelow. Callbefore you dig.  ® PLAN NO. 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 Mechanical, Electrical and Plumbing
(MEP) Consulting Engineers
W:\WE-CA\Cudahy, City of\112093 - Cudahy Park\1200-Submittals\1204-100% PS&E\Electrical\Cudahy ELEC CAD Pack\ DWG: E0-1.dwg LAYOUT: Layout1 1:0.5 October 30, 2025 - 11:26 CUDAHY PARK RENOVATION PROJECT PHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201 PROJECT NOTES, SYMBOLS & SHEET INDEX 1. MINIMUM WIRE SIZE FOR LINE VOLTAGE WIRING SHALL BE #12, UNLESS NOTED AS LARGER. 2. ALL CONDUIT SIZES SHALL CONFORM TO THE CALIFORNIA ELECTRICAL CODE (CEC) 2022 EDITION. MINIMUM SIZE CONDUIT SHALL BE 3/4". 3. NOT ALL SYMBOLS SHOWN IN THE SYMBOL LIST ARE USED ON THIS PROJECT. 4. COORDINATE WITH ALL OTHER TRADES IN ADVANCE OF CONSTRUCTION. 5. A GREEN INSULATED COPPER GROUNDING CONDUCTOR SHALL BE INSTALLED IN EACH AND EVERY CONDUIT AND SHALL BE CONNECTED TO EACH OUTLET, ENCLOSURE, DEVICE, FIXTURE, ETC. THROUGHOUT THE ENTIRE PROJECT. THE RACEWAYS SHALL NOT BE RELIED UPON FOR "EQUIPMENT GROUNDING". 6. PANEL HOMERUN DESIGNATIONS: BA 1&3&5 = ONE THREE PHASE, 3-WIRE CIRCUIT, NO NEUTRAL TO A 3-POLE CIRCUIT BREAKER IN PANEL "BA". BA 1&3 = ONE SINGLE PHASE, 2-WIRE CIRCUIT, NO NEUTRAL TO A 2-POLE CIRCUIT BREAKER IN PANEL "BA". BA 1-3-5 = THREE SINGLE PHASE CIRCUITS WITH COMMON NEUTRAL TO A 3-POLE CIRCUIT BREAKER IN PANEL "BA" PER CEC 210.4. BA 1-3 = TWO SINGLE PHASE CIRCUITS WITH COMMON NEUTRAL TO 2-POLE CIRCUIT BREAKER IN PANEL "BA" PER CEC 210.4. BA 2,4,6 = THREE SINGLE PHASE CIRCUITS WITH SEPARATE NEUTRAL FOR EACH CIRCUIT TO 1-POLE CIRCUIT BREAKER IN PANEL "BA". SEE DRAWINGS FOR ADDITIONAL VARIATIONS AND REQUIREMENTS 7. ALL MULTI-WIRE BRANCH CIRCUITS: PROVIDE A SEPARATE NEUTRAL FOR EACH PHASE CIRCUIT IN ALL MULTI-WIRE BRANCH CONDUIT RUNS BACK TO THE PANELBOARD. CIRCUIT BREAKERS WITH COMMON TIE HANDLES ARE NOT ALLOWED. NEUTRAL CONDUCTOR SHALL BE IDENTIFIED WITH A STRIP PHASE COLOR TO IDENTIFY ITS OWN CIRCUIT. 8. UNDERGROUND CONDUITS IN PLANTERS SHALL BE ROUTED ADJACENT TO CURBS TO ALLOW FOR PLANTING OF LARGE TREES. 1. THE CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AT THE JOB SITE. NEW WORK SHALL BE COORDINATED WITH ALL EXISTING MATERIALS, EQUIPMENT, SUPPORTS AND OBSTRUCTIONS. THE PLANS INDICATE DIAGRAMMATICALLY THE ROUTE REQUIRED FOR THE NEW CONDUIT INSTALLATION. 2. MAKE ALL NECESSARY ALTERATIONS TO COORDINATE AND CONNECT THE EXISTING WORK WITH THE NEW ELECTRICAL WORK SUCH THAT WHEN THE WORK IS COMPLETE, THE ENTIRE ELECTRICAL INSTALLATION, EXISTING AND NEW, IS IN A COMPLETE AND OPERABLE OPERATING CONDITION. 3. ALL DRILLING, PATCHING, CUTTING, CHANNELING OF MASONRY, PLASTER OR DRYWALL WHICH IS REQUIRED TO INSTALL THE ELECTRICAL WORK SHALL BE DONE BY THIS CONTRACTOR. 4. ALL NEW CONDUIT INSTALLED SHALL BE RIGID STEEL, EMT OR PVC. ALL CONDUCTORS SHALL BE COPPER. 5. NOT ALL EXISTING ELECTRICAL SYSTEMS WITHIN THE REMODELED AREA THAT MUST BE DEMOLISHED AND/OR REMOVED ARE SHOWN ON THE ELECTRICAL DRAWINGS. THE CONTRACTOR SHALL MAKE ALLOWANCES IN HIS BID FOR THE REMOVAL OF ELECTRICAL SYSTEMS WITHIN THE AREA OF REMODEL. BRANCH CIRCUITS SERVING ELECTRICAL SYSTEMS OUTSIDE THE AREA OF REMODEL SHALL BE RECONNECTED AND CONTINUITY MAINTAINED. ELECTRICAL EQUIPMENT INDICATED AS EXISTING TO BE RELOCATED SHALL CAREFULLY BE REMOVED AND STORED FOR FUTURE RE-INSTALLATION. THE CONTRACTOR MAY RE-USE ABANDONED CONDUITS FOR HOMERUNS TO EXISTING PANELS. PARKING WALKWAY LIGHT. SEE LIGHTING PLAN ON SHEET E2.1. SINGLE FLOODLIGHT FIXTURE. MAIN SWITCHBOARD OR DISTRIBUTION BOARD, FLOOR STANDING 90" HIGH. FLUSH MOUNTED PANELBOARD, +6'-6" TO TOP. FLUSH MOUNTED CABINET OR EQUIPMENT AS NOTED, +6'-6" TO TOP. SURFACE MOUNTED PANELBOARD, +6'-6" TO TOP. SURFACE MOUNTED CABINET OR EQUIPMENT AS NOTED, +6'-6" TO TOP. ELECTRICAL TRANSFORMER. 3/4" THICK PLYWOOD TERMINAL BOARD WITH SPECIAL FIRE RETARDANT TREATMENT AND WHITE PAINT, SIZE AS INDICATED OR SPECIFIED. PULL BOX. SEE DRAWING FOR SIZE. 3/4"C-2#12 3/4"C-4#12 1"C-6#10 1"C-7#10 3/4"C-5#10. 3/4"C-3#12. WIRE SIZE OTHER THAN #12 OR #10 IS NOTED ON EACH CONDUIT RUN WITH SIZE OF CONDUIT (e.g.: 3/4"C-3#8) INCLUDE A GREEN GROUND CONDUCTOR IN EACH CONDUIT. (GREEN GROUND CONDUCTOR NOT SHOWN). 1"C-8#10 1"C-10#10 1"C-11#10 1"C-9#10. LA NEW PANELBOARD DESIGNATION. MSA FEEDER DESIGNATION (SEE FEEDER SCHEDULE OR SINGLE LINE DIAGRAM). 12 REFERENCE NOTE FOR ITEM ON DRAWING. 150 INDICATES: 1 = FIXTURE TYPE; 50 = WATTAGE PER FIXTURE. ALSO NUMBER ADJACENT TO FIXTURE = CIRCUIT NUMBER, AND LOWER CASE LETTER = CONTROLLING SWITCH. SEE THE DRAWINGS OR THE SPECIFICATIONS FOR LIGHT FIXTURE DESCRIPTION. PROJECT NOTES ELECTRICAL SYMBOLS SPECIAL CONSTRUCTION NOTESWORK ON THIS PROJECT INCLUDES BUT NOT LIMITED TO: 1. PROVIDE NEW ELECTRICAL SERVICE FOR EXISTING CUDAHY PARK INCLUDE BASEBALL FIELD LIGHTING. 2. DISCONNECT AND REMOVE EXISTING POLE LIGHTING IN THE PARK. STORE REMOVAL LIGHTING FIXTURES PER CITY'S INSTRUCTION. PROVIDE AND INSTALL NEW WALKWAY POLE LIGHTING AND SPORT LIGHTING AT BASKETBALL COURT, TENNIS COURT AND SKATE PARK. 3. DISCONNECT AND REMOVE EXISTING LAMPS ON EXISTING POLE. REPLACE WITH NEW LAMPS ON EXISTING BASEBALL LIGHTING POLE. MUSCO TO RE-CONFIGURE LIGHTING CIRCUIT AND CONTROL. ADD TWO NEW LIGHTING POLE AS SHOWN ON PLAN. 4. PROVIDE POWER PROVISION FOR FUTURE SPLASH PAD, FUTURE AMPHITHEATER AND WATER FOUNTAIN AT BEDWELL HALL AND FUTURE STORAGE BUILDING. BRIEF SCOPE OF WORK SPORTS LIGHT FIXTURE WALKWAY LIGHTING STANDARD BASE DETAIL SCALE: NONE 1 E0.1 CONDUIT TRENCH DETAIL SCALE: NONE 3 E0.1 ROD WHEN REQUIRED. ADDITIONAL GROUND CONDUIT & WIRE TO 10'-0" FINISH GRADE NO. 3 HEAVY DUTY CONCRETE REINFORCED COVER. ENGRAVED "EQUIPMENT GROUND" CONDUIT HUB FOR GROUNDING BY "THOMAS" & BETTS." PRECAST 22"L. x 12" W. x 24"D YARD BOX. BROOKS PRODUCTS # 2PB (2 SECTIONS) OR QUICKSET # EOD22 (2 SECTIONS) CONDUIT AND WIRE SIZE AS REQUIRED SEE PLANS. GROUND FITTING THOMAS & BETTS # 2. 3/4" X 10' - 0" DRIVEN "COPPERWELD" GROUND ROD. GROUND ROD DETAIL SCALE: NONE 2 E0.1 E0.1 PROJECT NOTES, SYMBOLS & SHEET INDEX E0.2 ELECTRICAL SPECIFICATIONS E0.3 TITLE 24 OUTDOOR COMPLIANCE FORMS E0.4 TITLE 24 OUTDOOR COMPLIANCE FORMS E1.0 PARK DEMOLITION ELECTRICAL SITE PLAN E1.1 OVERALL ELECTRICAL SITE PLAN E2.1 ELECTRICAL SITE PLAN - WEST E3.1 PARK WALKWAY PHOTOMETRIC PLAN E3.2 BASKETBALL & TENNIS COURT PHOTOMETRY PLAN & POLE DETAIL E3.3 BASKETBALL & TENNIS COURT LIGHTING, PHOTOMETRY & INSTALLATION DETAIL E4.1 SINGLE LINE DIAGRAM E4.2 PANEL AND FIXTURE SCHEDULES SHEET INDEX EXISTING POLE LIGHT. EXISTING POLE LIGHT. 24" 36" DIA. 3" MIN. 2" MIN. SIX #4 VERTICAL REINFORCING BARS PSI SHALL BE CALCULATED BY STRUCTURAL ENGINEER OR PER SPECIFICATIONS SEVEN HOOP TIES (#5 REINFORCING BARS) SPACED EQUALLY 48" FINISH GRADE CONCRETE FOOTING SEE SITE LIGHTING PLAN FOR SIZE OF CONDUIT AND NUMBER OF WIRES 6" 41" DETAIL 1 - ANCHOR BOLT DETAIL CONCRETE PEDESTAL HAND HOLE OPENING DETAIL 2 - BOLT COVER DETAIL 8" O.D. SMOOTH EXTRUDED TUBE, 6061 ALLOY, 0.1875" WALL THICKNESS NOTES: THE MINIMUM TO TOP OF ENCASEMENT DEPTH SHALL BE 24". 3" MINIMUM ENCASEMENT AROUND CONDUITS. BACKFILL AND ENCASEMENT SHALL BE "RED CONTROLLED LOW STRENGTH MATERIAL" (CONCRETE SLURRY). COLD JOINT BETWEEN ENCASEMENT AND SLURRY BACKFILL REFER TO DRAWINGS FOR CONDUIT SIZES. REFER TO SPECIFICATIONS FOR CONDUIT AND FITTING TYPES. CONDUIT SPACING MAY BE REDUCED WHERE CONDUITS ENTER EQUIPMENT ENCLOSURES FROM UNDERGROUND. SLURRY ENCASEMENT (BACKFILL) IN EXISTING ROADWAYS SHALL EXTEND UP TO THE TOP OF THE SUB BASE COURSE WITH 6.5" OF NEW A.C. PAVING, EXCEPT AT WATER LINE CROSSINGS. AT THESE LOCATIONS THE 24" SECTION OF SLURRY ENCASEMENT SHALL BE OMITTED AND THE TOP OF THE CONDUIT ENCASEMENT SHALL BE 36" BELOW GRADE. BACKFILL WITH SLURRY OVER ENCASEMENT COLD JOINT. 1234
4 1 FIN. GRADE YELLOW VINYL DETECTABLE TAPE MARKED "DANGER ELECTRICAL" SIX (6) CONDUITS3 CL
CL
PP
P
P
2 2
P
P
6"-8"
BELOW
GRADE DETAIL 3 -BASE PLATE DETAIL NEW BASEBALL FIELD LIGHTING POLE. EXISTING BASEBALL FIELD LIGHTING POLE. (2) #5 TIES WITH 5" OF TOP (2) #5 TIES WITH 5" OF TOP E0.1 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1178 of 1214 27 63 BID SET

Page 1208 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E0-2.dwg LAYOUT: Layout1 1:0.5 October 23, 2025 - 9:34:17AM stanley ELECTRICAL SPECIFICATIONS ELECTRICAL SPECIFICATIONS IT IS THE INTENT AND PURPOSE OF THESE SPECIFICATIONS AND ACCOMPANYING DRAWINGS THAT THE CONTRACTOR PROVIDE THE NECESSARY MATERIALS, LABOR, WORKMANSHIP, TOOLS, EQUIPMENT, TRANSPORTATION, ETC., FOR THE COMPLETE AND PROPER INSTALLATION AND OPERATION OF THE VARIOUS ELECTRICAL SYSTEMS SPECIFIED HEREIN. VISIT THE PREMISES TO BECOME ACQUAINTED WITH THE CONDITIONS TO BE ENCOUNTERED. NO EXTRA PAYMENTS WILL BE ALLOWED FOR ANY EXTRA WORK WHICH MAY BE REQUIRED DUE TO FAILURE OF THE CONTRACTOR TO THOROUGHLY EXAMINE THE PREMISES PRIOR TO BID. WORK INCLUDED IN THIS SECTION PROVIDE NEW ELECTRICAL SERVICE FOR EXISTING CUDAHY PARK INCLUDE BASEBALL FIELD LIGHT. A COMPLETE AND OPERABLE EXTENSION OF THE EXISTING 208/120V, 3-PHASE, 4-WIRE AND 480/277V, 3-PHASE, 4-WIRE LIGHTING AND POWER SYSTEMS INCLUDING CONDUITS, CONDUCTORS, WIRE, FITTINGS, FIXTURES, RECEPTACLES, SWITCHES, ETC. LIGHTING FIXTURES, LAMPS AND ACCESSORIES, INCLUDING REPLACING LAMPS, BALLASTS, AND LENS IN EXISTING LIGHT FIXTURES FOR A COMPLETE AND OPERABLE LIGHTING SYSTEM. APPLICABLE CODES AND REGULATIONS 2022 CALIFORNIA ELECTRICAL CODE. REGULATIONS OF ALL OTHER AUTHORITIES HAVING JURISDICTION. PERMITS AND APPROVALS AS REQUIRED BY CITY ORDINANCES TO BE OBTAINED AND PAID FOR BY THE CONTRACTOR. LOCATIONS THE DRAWINGS INDICATE DIAGRAMMATICALLY THE DESIRED LOCATION OR ARRANGEMENT OF CONDUIT RUNS, OUTLETS, EQUIPMENT, ETC., AND ARE TO BE FOLLOWED AS CLOSELY AS POSSIBLE. PROPER JUDGMENT MUST BE EXERCISED IN EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE AVAILABLE SPACE AND TO OVERCOME DIFFICULTIES OWING TO SPACE LIMITATIONS OR THE INTERFERENCE OF STRUCTURAL CONDITIONS WHEREVER ENCOUNTERED. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY AND COORDINATE THE LOCATION OF ALL OUTLETS AND LIGHTING FIXTURES WITH THE ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS AND WITH ALL SHOP DRAWINGS, INCLUDING CASEWORK SHOP DRAWINGS. ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS SHALL GENERALLY TAKE PRECEDENCE. HOWEVER, IN THE EVENT OF LARGE VARIATIONS BETWEEN ARCHITECTURAL AND ELECTRICAL DRAWINGS THE ARCHITECT SHALL BE CONSULTED FOR INSTRUCTIONS. UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL LIGHTING FIXTURES AND/OR FIXTURE STEMS SHALL BE PLACED SYMMETRICALLY WITH RESPECT TO THE CEILING TILE PATTERN OR OTHER ARCHITECTURAL CEILING AND WALL MODULES. REPAIRS ANY DAMAGE TO THE STRUCTURE OR FINISHED SURFACES DUE TO THE INSTALLATION OF THE ELECTRICAL WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE REPAIR BY THE TRADESMEN OF THE TRADE INVOLVED. SHOP DRAWINGS PROVIDE ELECTRONIC PDF COPIES OF CATALOG CUTS FOR EACH OF THE FOLLOWING ITEMS: 1. SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES AND MOTOR STARTERS 2. MATERIAL LIST. 3. LIGHT FIXTURES. 4. TRANSFORMERS. 5. LIGHTING CONTROL DEVICES 6. LIGHTING CONTROL SYSTEMS STRUCTURAL CONDITIONS PENETRATE NO STRUCTURAL ELEMENTS INCLUDING SHEAR WALLS, WITHOUT WRITTEN CONSENT OF ARCHITECT. CORE DRILLING AND HAMMER DRILLING REQUIREMENTS CUTTING OR DAMAGING REBAR OR EMBEDDED CONDUITS, DURING CORE DRILLING OR HAMMER DRILLING OPERATIONS NOT PERMITTED. SHOT PINS, PILOT DRILLING AND DESTRUCTIVE INVESTIGATION TO LOCATE REBAR WILL NOT BE PERMITTED. PRIOR TO DRILLING THE AREA SHALL BE MAPPED TO DETERMINE THE LOCATIONS OF REBAR AND CONDUITS USING A CONCRETE X-RAY UNIT. CORE DRILLING OR HAMMER DRILLING SHALL BE 2" MINIMUM CLEAR FROM REBAR AND JOINTS AND 4" MINIMUM CLEAR FROM EDGE. PROVIDE WEATHERPROOF SEALANT AROUND EXTERIOR DRILLING. PENETRATIONS IN FIRE-RATED WALLS, CEILINGS, FLOOR CEILING ASSEMBLIES AND MEMBRANE PENETRATIONS TO BE PROTECTED BY APPROVED FIRE STOP MATERIALS PER CEC 300.21CEC. COORDINATION REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR WIRING, DIAGRAMS, EXACT EQUIPMENT LOCATION, AND OTHER INFORMATION REGARDING THE EXTENT OF ELECTRICAL WORK REQUIRED BUT NOT INDICATED ON ELECTRICAL DRAWINGS. EXCAVATIONS DO ALL EXCAVATING NECESSARY FOR THE PROPER INSTALLATION OF THE ELECTRICAL WORK WHETHER OR NOT INDICATED ON THE DRAWINGS OR SPECIFIED. WHEN ON THE OWNER'S PROPERTY, UNDERGROUND PRIMARY AND SECONDARY SERVICES, AND HIGH VOLTAGE FEEDERS SHALL BE BURIED NOT LESS THAN 24" BELOW FINISHED GRADE. UNDERGROUND CONDUITS IN OR CROSSING ROADWAYS, PARKING LOTS SHALL BE BURIED NOT LESS THAN 24” BELOW GRADE. ALL UNDERGROUND CONDUIT 1-1/2” AND LARGER SHALL BE ENCASED IN CONCRETE. OTHER CONDUIT RUNS CONTAINING CIRCUITS OF 600 VOLTS OR LESS SHALL BE NOT LESS THAN 18" BELOW FINISH GRADE. WHERE CONDUIT RUNS TRAVERSE PUBLIC PROPERTY, THE DEPTH BELOW FINISH GRADE SHALL BE AS REQUIRED BY THE LEGALLY CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION. AFTER THE INSTALLATION OF WORK REQUIRING EXCAVATIONS HAS BEEN INSPECTED AND APPROVED, ALL EXCAVATIONS SHALL BE FILLED WITH CLEAN EARTH AND TAMPED TO A CONSISTENCY SO THAT NO SETTLEMENT WILL OCCUR, AND THE GROUND LEFT FIRM AT NATURAL GRADE. ALL EXCAVATED EARTH WHICH IS NOT USED FOR BACKFILL SHALL BE REMOVED FROM THE PREMISES OR OTHERWISE DISPOSED OF AS DIRECTED. ALL PLANTS, SHRUBS, TURF AND SURFACING THAT OCCUR IN THE AREA OF THE EXCAVATION SHALL BE CAREFULLY REMOVED AND PLACED WHERE THEY WILL NOT BE DAMAGED. AFTER THE EXCAVATIONS ARE FILLED, THE PLANTS, SHRUBS, TURF AND SURFACING SHALL BE REPLACED AS DIRECTED. ALL SIDEWALKS, DRIVEWAYS OR OTHER CEMENT OR ASPHALT SURFACES WHICH ARE DAMAGED DURING EXCAVATION SHALL BE REPAIRED TO MATCH THE ADJACENT WORK IN MATERIAL AND FINISH. CONDUITS INSTALL ALL CONDUIT CONCEALED EXCEPT AS NOTED ON DRAWINGS. GALVANIZED OR SHERARDIZED RIGID STEEL CONDUIT FOR EXPOSED CONDUIT BELOW 8 FT. WHEN USED EXPOSED ON EXTERIOR OR WHEN INSTALLED IN MASONRY OR CONCRETE. USE GALVANIZED COUPLINGS, LOCKNUTS, BUSHINGS, AND CONNECTORS. NON-METALLIC: RIGID PVC ELECTRICAL CONDUIT EXTRUDED TO SCHEDULE 40 DIMENSIONS OF HIGH IMPACT, VIRGIN POLYVINYL CHLORIDE AND SHALL BEAR U.L. LABEL. PVC, SCHEDULE 40 CONDUIT SHALL BE USED FOR ALL UNDERGROUND RUNS. ENCASE IN CONCRETE OF 3" MINIMUM THICKNESS ON ALL SIDES. USE STANDARD STEEL CONDUIT ELLS WHEREVER A RUN TURNS UP ABOVE GROUND OR CONCRETE SLABS. WHERE CONDUIT SIZE IS INCREASED FOR GROUND CONDUCTOR BY A CHANGE TO PVC, INCREASE THE SIZE OF THE ENTIRE LENGTH OF THE CONDUIT RUN TO MATCH. PVC CONDUIT SHALL NOT BE USE FOR UNDERGROUND BRANCH CIRCUITS SERVING RECEPTACLES AND FIXED EQUIPMENT IN PATIENT CARE AREAS PER CEC 517.13. ELECTRICAL METALLIC TUBING: THIN WALL, GALVANIZED STEEL WITH COMPRESSION FITTINGS ONLY: FOR ALL CONCEALED WORK OR WHEN EXPOSED ABOVE 8FT. FLEXIBLE METALLIC CONDUIT: SPIRAL INTERLOCKED, GALVANIZED STEEL, FOR CONDUIT CONCEALED ABOVE GROUND, NOT ENCASED IN MASONRY OR CONCRETE AND PROHIBITED IN WET OR DAMP LOCATIONS; SEAL-TITE OIL RESISTANT FLEXIBLE CONDUIT WITH PROPER FITTINGS FOR WET OR DAMP LOCATIONS. WHERE FLEXIBLE METALLIC CONDUIT IS PERMITTED, THE TOTAL LENGTH OF THE CONDUIT IN ANYONE RUN SHALL NOT EXCEED 6 FEET. INSTALL METALLIC CONDUIT AS A COMPLETE SYSTEM, CONTINUOUS FROM OUTLET TO OUTLET, CABINET, BOX OR FITTINGS, AND SO MECHANICALLY AND ELECTRICALLY CONNECTED THAT ADEQUATE ELECTRICAL CONTINUITY FROM ONE CONDUIT TO ANOTHER IS SECURED. HOWEVER, THIS SHALL NOT CONSTITUTE THE MECHANICAL GROUND FOR THE CIRCUIT. INSTALL CONDUIT AS INDICATED ON PLANS AND FIRMLY SECURED AT LEAST 6" FROM ANY HOT WATER PIPE, HOT AIR DUCT, FLUE OR VENT. FLASH AND COUNTER FLASH ALL CONDUIT PENETRATING SLOPED ROOFS WITH GALVANIZED SHEET STEEL ROOF JACKS. ALL PENETRATIONS THROUGH FLAT ROOF SURFACES BY ELECTRICAL CONDUIT SHALL BE THROUGH PITCH POCKET PANS A MINIMUM OF 6" LARGER THAN THE CONDUIT. PAN SHALL BE FILLED WITH HOT COAL TAR PITCH. CONDUCTORS FEEDERS: #6 AND LARGER SHALL BE COPPER TYPE XHHW-2, RHH, RHW-2, THW OR USE-2 WITH HIGH TEMPERATURE RATING OF 90 DEGREES C. WET OR DRY AND A LOW TEMPERATURE RATING OF -25 DEGREES C. SHALL BE USED FOR ALL OTHER 600 VOLT WIRING EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. TYPE THHN/THWN INSULATION CONDUCTORS SHALL NOT BE SUBSTITUTED FOR TYPE XHHW_2 EXCEPT AS SPECIFIED IN THE PRECEDING PARAGRAPH OR UNLESS SPECIFICALLY PERMITTED ON THE DRAWINGS. BRANCH CIRCUITS: LIGHTING AND POWER 1. #12 AWG MINIMUM, SOLID, OR STRANDED COPPER WIRE TYPE THHN/THWN, THHW, THWN-2 (THHN FOR DRY LOCATION ONLY). 2. #8 AWG AND SMALLER, STRANDED COPPER TYPE THHN/THHW-2. CONDUCTORS INSTALLED IN AREAS SUBJECTED TO TEMPERATURES EXCEEDING 60 DEG C (140 DEG F); TERMINATING IN INCANDESCENT LIGHTING SHALL BE TYPE AVA OR RHW-2. FOR CONDUCTORS INSTALLED IN EXPOSED CONDUIT OUTSIDE OF BUILDINGS, IN EXPOSED CONDUIT IN TUNNEL AND CONDUIT WITHIN OR JUST UNDER ROOFING MATERIAL, PROVIDE TYPE XHHW-2 90 DEGREE RATED. CONTROL CIRCUITS: USE 600 VOLTS UL TYPE THHN/THWN OR THWN-2 CONDUCTORS EXCEPT WHERE SUBJECT TO ABNORMALLY HIGH TEMPERATURES SUCH AS ON OR NEAR BOILERS. UNDER THESE CONDITIONS, USE UL TYPE XHHW. WIRING THROUGH LED AND FLUORESCENT FIXTURES IN CONTINUOUS ROWS SHALL BE TYPE THHN. DO NOT USE ANY MECHANICAL DEVICE TO PULL WIRE UNLESS SPECIFICALLY APPROVED BY THE ELECTRICAL ENGINEER. IDEAL YELLOW #77 OR EQUAL PULLING COMPOUND IS THE ONLY LUBRICANT PERMITTED FOR PULLING WIRE. USE SPLIT BOLT OR HI-PRESS COMPRESSION CONNECTORS FOR #6 AWG AND LARGER CONDUCTORS. WRAP JOINTS WITH A MINIMUM OF THREE (3) LAYERS OF SCOTCH TAPE #33 WHERE SPLICES ARE TO BE WATERPROOFED. ADD PROPER HEAT-SHRINK OR COLD-SHRINK TUBES OR WITH A 3M SCOTCHCAST EPOXY RESIN. USE 3M SCOTCHLOK OR IDEAL WING-NUT CONNECTIONS FOR #8 AWG AND SMALLER CONDUCTORS. NO SPLICES SHALL BE ALLOWED IN ANY CAST IRON OR CONCRETE PULL BOX UNLESS IT IS SPECIFICALLY CALLED FOR ON THE DRAWINGS OR IT IS WITH THE SPECIFIC WRITTEN APPROVAL OF THE ELECTRICAL ENGINEER. WHEN SPLICES ARE ALLOWED, A THOMAS & BETTS NO. HS-LR SERIES WATERTIGHT HEAT SHRINK PROCESS JACKET OVER THE SPLICE SHALL BE USED. MAKE ALL SPLICES WATERTIGHT FOR EXTERIOR EQUIPMENT AND EQUIPMENT IN PUMP ROOMS. OUTLET BOXES GALVANIZED PRESSED STEEL, KNOCKOUT TYPE FOR GENERAL INTERIOR WIRING. PROPER SIZE FOR NUMBER OF WIRES BUT NOT LESS THAN 4" SQUARE. WATERPROOF CAST BOXES FOR EXTERIOR WIRING AND IN WET OR DAMP LOCATIONS. MANUFACTURED BY CROUSE HINDS OR APPLETON. SWITCHBOARDS PROVIDE NEMA STANDARD DESIGNED, DEAD FRONT, DEAD REAR, BUS BARS OF 98 PERCENT COPPER, BRACED FOR 50,000 AMPERES RMS SYMMETRICAL AVAILABLE FAULT CURRENT SWITCHBOARD FABRICATED AND ASSEMBLED BY ONE MANUFACTURER. DESIGN OF SWITCHBOARD TO BE COMPATIBLE WITH CODE REQUIREMENTS AND THE REQUIREMENTS OF THE OF THE SERVING UTILITY COMPANY. INCLUDE THE UTILITY METERING EQUIPMENT, COMPONENTS, AND MOUNTING DEVICES AS THOUGH SPECIFIED HEREIN. OVERCURRENT DEVICES SHALL BOLT-ON QUICK-LAG, AMBIENT COMPENSATED, THERMAL MAGNETIC TYPE SINGLE HANDLE, COMMON TRIP FOR 2 AND 3 POLES BREAKERS. PANELBOARDS BOLT-ON TYPE, AMBIENT COMPENSATED, THERMAL MAGNETIC TYPE CIRCUIT BREAKERS RATED MINIMUM 10,000 AIC, SINGLE HANDLE, COMMON TRIP FOR 2 AND 3 POLE BREAKERS. BUSSING SHALL BE COPPER. INSTALL A TYPEWRITTEN DIRECTORY ON INSIDE OF DOOR TO DESIGNATE OUTLETS OR EQUIPMENT SERVED BY CIRCUIT. FLUSH OR SURFACE MOUNTED AS INDICATED WITH HAMMERTONE GRAY FINISH AS MANUFACTURED BY SQUARE "D". FLUSH PANEL TRIM SHALL BE A ON PIECE ASSEMBLY WITH HINGED LOCKABLE DOOR. “EZ-TRIM” ASSEMBLY WILL NOT BE ACCEPTABLE. ALL PANELBOARDS SHALL HAVE BUS BRACING AND CIRCUIT BREAKER FAULT INTERRUPTING CAPABILITY TO WITHSTAND AND INTERRUPT THE AVAILABLE RMS SYMMETRICAL FAULT CURRENTS INDICATED ON THE DRAWINGS. IN NO CASE, HOWEVER, SHALL THIS CAPABILITY BE LESS THAN 10,000 AMPERES AT 208/240 VOLTS AND 14,000 AMPERES AT 480 VOLTS. ALL PANELBOARDS REQUIRING COMPLIANCE WITH THE CALIFORNIA ENERGY CODE SHALL HAVE A CAPABILITY OF ADDING FUTURE BRANCH CIRCUIT METERING CIRCUIT BREAKERS USING SQUARE “D” TYPE BCPM BRANCH METERING CIRCUIT BREAKER IN THE FUTURE. PANELBOARDS BY OTHER MANUFACTURES SHALL BE EQUIPPED WITH SPLIT-BUS FOR INSTALLING FUTURE DEMAND METERS IN ACCORDANCE WITH THE CODE. EXTERIOR WEATHERPROOF PANELBOARDS SHALL BE NEMA TYPE 3R, NEMA 5 AND NEMA 12 RATED WITH GASKETING AND OTHER AMENITIES TO COMPLY WITH ALL RATINGS. DISCONNECT SWITCHES DISCONNECT SWITCHES SHALL BE 250 VOLT OR 600 VOLT A.C., COMPLYING WITH SOURCE VOLTAGE, HEAVY DUTY NEMA TYPE HD, QUICK MAKE, QUICK BREAK, HORSEPOWER RATED, NON-FUSIBLE OR FUSIBLE SWITCHES IN NEMA TYPE 1 ENCLOSURE WITH NUMBER OF POLES AND AMPERAGE AS INDICATED ON THE DRAWINGS. FUSIBLE SWITCHES SHALL BE EQUIPPED WITH REJECTION CLIPS TO PREVENT THE USE OF ONE-TIME AND RENEWABLE FUSES. WHERE THE ENCLOSURE IS INDICATED WEATHERPROOF, AND FOR OUTDOOR USE, SWITCHES SHALL BE IN RAINTIGHT NEMA TYPE 3R ENCLOSURE. WHERE FUSES ARE REQUIRED, PROVIDE DUAL ELEMENT "BUSS" "FUSETRON" FUSES UNLESS OTHERWISE INDICATED ON DRAWING. TRANSFORMERS TRANSFORMERS SHALL BE INDIVIDUAL, DRY TYPE, AIR COOLED, TWO WINDING TYPE. PROVIDE COPPER WINDINGS OF THE CAPACITY AND VOLTAGE RATINGS INDICATED. EQUIP THE WINDINGS WITH TWO 2-1/2% FCAN AND TWO 2-1/2% FCBN TAPS. PERFORMANCE OF TRANSFORMERS SHALL MEET OR EXCEED THE REQUIREMENTS OF APPLICABLE CODES AND STANDARDS, 2005 ENERGY ACT PUBLIC LAW 109-58--AUG. 8, 2005, AND COMPLY WITH ALL RULES FROM DEPARTMENT OF ENERGY 10 CFR 429 AND 10 CFR 431 AND THE LATEST REQUIREMENTS OF THE CALIFORNIA ENERGY COMMISSION APPLIANCE EFFICIENCY REGULATIONS. TRANSFORMERS SHALL BE SELF-COOLED TYPE WITH 220 DEGREES C. INSULATION AND A MAXIMUM TEMPERATURE RISE OF 150 DEGREES C. UNDER CONTINUOUS FULL LOAD CONDITIONS WITH AN AMBIENT OF 40 DEGREES C. EQUIP TRANSFORMERS WITH VIBRATION DAMPENERS (KORFUND COMPANY OR EQUIVALENT) SEPARATING CORE AND COIL ASSEMBLY FROM THE STRUCTURAL MEMBERS OF THE ENCLOSURE. SOUND LEVEL EMITTED UNDER FULL LOAD SHALL BE (5) DECIBELS BELOW NEMA SOUND LEVEL LIMITS. CONSTRUCT ENCLOSURES OF HEAVY GAUGE SHEET STEEL, PRIMED INSIDE AND OUT WITH A ZINC CHROMATE OR IRON OXIDE RUST INHIBITING PRIMER. FINISH WITH GRAY ENAMEL PAINT. USE MANUFACTURER'S STANDARD GRAY COLOR UNLESS A PARTICULAR ASA COLOR IS INDICATED OR SPECIFIED. PROVIDE TRANSFORMERS AS MANUFACTURED BY SQUARE D, MGM, GENERAL ELECTRIC OR EATON. FURNISH SHOP DRAWINGS SHOWING EFFICIENCIES AT NO LOAD, 1/4, 1/2, 3/4 AND FULL LOAD CONDITIONS, MAXIMUM DECIBEL NOISE LEVEL, AND TEMPERATURE RISE AT FULL LOAD. TRANSFORMER SHALL BE FLOOR MOUNTING ON COMPOSITION ISOLATION VIBRATION PADS WHICH ARE SPECIFICALLY SIZED FOR THE TOTAL WEIGHT OF THE UNIT AND DESIGNED TO MINIMIZE TRANSMISSION OF 120 HERTZ SOUND. THE ISOLATORS SHALL ALSO BE DESIGNED TO PROVIDE SEISMIC RESTRAINT IN A MANNER AND TO A DEGREE ACCEPTABLE TO THE STRUCTURAL ENGINEER. FINAL CONNECTIONS TO EACH DRY TYPE TRANSFORMER SHALL BE SUCH AS TO MINIMIZE TRANSMISSION OF VIBRATION. THERE SHALL BE NO RIGID CONDUIT OR OTHER METAL TO METAL CONTACT WITH THE TRANSFORMERS WHICH WOULD TRANSMIT TRANSFORMER GENERATED NOISE AWAY FROM THE UNIT. DEVICES CIRCUIT SWITCHES 1. CIRCUIT SWITCHES SHALL BE WHITE, TOTALLY ENCLOSED, BAKELITE, OR COMPOSITION BASE, TOGGLE TYPE WITH 277 VOLT, A.C. RATING FOR FULL CAPACITY OF CONTACTS FOR INCANDESCENT OR FLUORESCENT LAMP LOADS. SWITCH RATINGS SHALL BE 20 AMPERES ONLY. SWITCHES SHALL BE BACK AND SIDE WIRED. 2. LOCK TYPE SWITCHES SHALL MATCH EXISTING SWITCHES WHERE NEW WORK CONSISTS OF REHABILITATION OR ADDITION TO EXISTING WORK. 3. SWITCHES SHALL BE WHITE COLOR FOR NORMAL POWER AND RED WHEN CONNECTED TO EMERGENCY POWER. DIMMERS1. 0-10 VOLT LED WALL BOX DIMMERS SHALL BE GREENGATE #WBSD-010SLD-W (WHITE) OR APPROVED EQUAL. DIMMER SHALL BE RATED 8.0 AMPS AT 120-277 VOLTS. 2. 0-10 VOLT LED WALL BOX DIMMER OCCUPANCY SENSORS SHALL BE GREENGATE #OSW-D-010-W (WHITE) OR APPROVED EQUAL. DIMMER SHALL BE RATED 8.0 AMPS AT 120-277 VOLTS. DUPLEX RECEPTACLES 1. DUPLEX RECEPTACLES SHALL BE WHITE, GROUNDING TYPE, 125 VOLT, 20 AMPERE AND SHALL HAVE TWO CURRENT CARRYING CONTACTS AND ONE GROUNDING CONTACT WHICH IS INTERNALLY CONNECTED TO THE FRAME. OUTLET SHALL ACCOMMODATE STANDARD PARALLEL BLADE CAP AND SHALL BE SIDE WIRED ONLY. RECEPTACLES SHALL HAVE SELF-GROUNDING STRAPS, WHICH ARE U.L. APPROVED FOR INSTALLATION WITHOUT A BONDING JUMPER. 2. RECEPTACLES SHALL BE INSTALLED WITH THE "U" GROUNDING CONTACT AT THE TOP, EXCEPT FOR RECEPTACLES INSTALLED FOR FIXED APPLIANCES. WHERE RECEPTACLES NEED TO BE MOUNTED HORIZONTALLY, THEY SHALL BE INSTALLED WITH THE NEUTRAL CONTACT AT THE TOP. 3. DUPLEX G.F.I. RECEPTACLE: GROUNDING TYPE DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER SHALL CONFORM TO NEMA CONFIGURATION 5-20R, 20-AMP RECEPTACLE AND A CIRCUIT CAPACITY OF 20 AMPERES. RECEPTACLE SHALL BE SELF TESTING TO PROVIDE CONTINUOUS ELECTRONIC SENSING & TESTING, UTILIZING DIAGNOSTIC SOFTWARE - IMMEDIATE INDICATION IF UNIT HAS LOST THE ABILITY TO PROTECT. RECEPTACLE SHALL TRADITIONAL TESTING MODE BY MANUALLY OPERATING THE “TEST AND RESET” BUTTONS. WHEN LEAKAGE EXCEEDS 5 M.A., THE INTERRUPTER SHALL OPEN THE CIRCUIT AT THE RECEPTACLE WITHIN 1/30 OF A SECOND. INTERRUPTER SHALL ONLY PROTECT THE RECEPTACLE INDICATED UNLESS INDICATED ON THE DRAWINGS AS FEED-THRU TYPE. RECEPTACLE SHALL BE COMPLETE WITH TEST AND RESET BUTTONS. RECEPTACLE SHALL BE INSTALLED IN A 4" SQUARE BY 2_1/8" DEEP BOX WITH SINGLE GANG PLASTER RING COMPLETE WITH STAINLESS STEEL PLATE AT DRY LOCATIONS AND WEATHERPROOF HINGED DOOR COVER WHERE INDICATED AS WEATHERPROOF (W.P.). ON EXPOSED CONDUIT RUNS USE FD CONDULET WITH HINGED COVER. RECEPTACLE SHALL BE WHITE, HUBBELL #GFR5352IST OR APPROVAL EQUAL WITH SELF TEST DIAGNOSTIC DESIGN. ALL EXTERIOR GFI RECEPTACLES SHALL IDENTIFIED AND UL LISTED AS WEATHER RESISTANT (WR) AND "EXTRA DUTY". 4. OTHER DEVICES: WHITE COLOR, SPECIFICATION GRADE, OF TYPE NOTED IN SYMBOL LIST AND PLANS. 5. MANUFACTURED BY PASS & SEYMOUR, LEVITON, BRYANT, GENERAL ELECTRIC OR ARROW-HART. DEVICE PLATES 1. REQUIRED FOR ALL WIRING DEVICES, TELEPHONE AND DATA OUTLETS AND SIMILAR APPLICATIONS. 2. WALL PLATES: (WHITE, PLASTIC), (0.040” TYPE 302 ALLOY STAINLESS STEEL), SPECIFICATION GRADE, STANDARD SIZE, SMOOTH AND SHALL BE LISTED BY UNDERWRITERS' LABORATORIES. ALL WALL PLATES SHALL BE OF ONE MAKE AND DESIGN, EQUAL TO PASS & SEYMOUR (PLASTIC LINE) (STAINLESS STEEL LINE). ENGRAVE ALL PLATES AS NOTED ON PLANS OR OF 3 GANG OR MORE. ALLOW 15 CHARACTERS PER GANG. 3. GANG COVERS FOR GANG BOXES. DEVICE ENGRAVING 1. ALL CIRCUIT SWITCH, RECEPTACLE AND POWER OUTLET BOX DEVICE PLATE SHALL BE ENGRAVED WITH THE 1/4" HIGH LETTERS WITH BLACK FILL TO INDICATE THE CIRCUIT NUMBER AND PANEL BOARD SERVING OR BEING CONTROLLED BY THE DEVICES, E.G. "1LCL 2" INDICATES PANEL "1LCL" CIRCUIT "2". DEVICES ON EMERGENCY POWER SHALL RED FILL LETTERS. NAMEPLATES PROVIDE BLACK-ON-WHITE NAMEPLATES FOR EACH SWITCHBOARD, PANEL, TERMINAL CABINET, CONTROL CENTER, PULL BOX, DISCONNECT SWITCH AND MAGNETIC MOTOR STARTER TO CORRESPOND WITH DESIGNATIONS ON THE DRAWINGS. NAMEPLATES SHALL BE SECURED WITH SCREWS, BOLTS OR RIVETS. OTHER MEANS OF ATTACHMENT SHALL NOT BE ACCEPTED. "DYMO" TYPE LABELS WILL NOT BE ACCEPTED. NAMEPLATES FOR DEVICES OR EQUIPMENT SUPPLIED BY EMERGENCY POWER SHALL BE RED-ON-WHITE. LIGHTING FIXTURES SEE LUMINAIRE SCHEDULE ON SHEET E4.2 WARRANTY PROVIDE A WARRANTY FOR ALL LABOR AND EQUIPMENT FOR A PERIOD OF ONE YEAR AFTER THE ACCEPTANCE OF THE PROJECT. ANY ELECTRICAL TROUBLE DEVELOPING DURING THIS PERIOD DUE TO FAULTY WORKMANSHIP OR MANUFACTURE SHALL BE COVERED UNDER THE WARRANTY AND IMMEDIATELY CORRECTED AT NO COST TO THE OWNER. TESTSTEST ALL WIRE FOR SHORTS, OPENS, GROUNDS, OR OTHER DEFECTS; CORRECT ANY DEFECTIVE WORK. DEMONSTRATE CONTINUOUS SATISFACTORY OPERATION OF ALL ELECTRICAL WORK WITH THE OWNER BY RUNNING THROUGH MANUAL OPERATIONS. E0.2 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1179 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
28 63 BID SET

Page 1209 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E0-3.dwg LAYOUT: Layout1 1:0.5 October 23, 2025 - 9:35:04AM stanley TITLE 24 OUTDOOR COMPLIANCE FORMS E0.3 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1180 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
29 63 BID SET

Page 1210 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E0-4.dwg LAYOUT: Layout1 1:0.5 October 23, 2025 - 9:49:59AM stanley TITLE 24 OUTDOOR COMPLIANCE FORMS E0.4 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1181 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
30 63 BID SET

Page 1211 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E1-0.dwg LAYOUT: Layout1 1:0.5 October 23, 2025 - 10:05:32AM stanley PARK DEMOLITION ELECTRICAL SITE PLAN E1.0 PARK DEMOLITION ELECTRICAL SITE PLAN SCALE: 1" = 20'-0" 1 E1.0 115 (N) CONC. SLAB, PER (N) ROLL-UP DOOR PANEL (N) STORAGE ROOM 600 SQ.FT. STRUCTURAL DWG. (N) ELECTRICAL 115 2 1 1 2 2 2 2 2 2 1 EXISTING BEDWELL HALL EXISTING CITY HALL BUILDING EXISTING BUILDING 3 FUTURE SPLASH PAD CHILDREN PLAYGROUNDSKATE PARK OUTDOOR FITNESS BASKETBALL COURT TENNIS COURT REFERENCE NOTES 1. PROTECT EXISTING POLE LIGHTING BRANCH CIRCUIT AS IS. 2. DISCONNECT AND REMOVE EXISTING POLE LIGHTING AND ASSOCIATED BRANCH CIRCUIT CONDUCTORS. ABANDON EXISTING UNDERGROUND CONDUITS. 3. DISCONNECT AND REMOVE EXISTING LAMPS ON EXISTING POLE FOR BASEBALL FILED. RE-USE EXISTING POLE PER MUSCO'S INSTRUCTION OF INSTALLATION NEW MUSCO LAMP ON EXISTING POLE. EXISTING LAMPS SHALL BE DELIVERED TO THE LOCATION DESIGNED BY THE CITY OR SHALL BE DISPOSED OF AS DIRECTED BY THE CITY. # Cudahy Park Renovation Project, Project # PRE-001 Document Control 1182 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
PHASE 2
(N.I.C.) PHASE 1
PHASE 2
(N.I.C.) 31 63 BID SET

Page 1212 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E1-2.dwg LAYOUT: Layout1 1:0.5 October 24, 2025 - 9:00:28AM stanley OVERALL ELECTRICAL SITE PLAN E1.2 (N) CONC. SLAB, PER (N) ROLL-UP DOOR PANEL (N) STORAGE ROOM 600 SQ.FT. STRUCTURAL DWG. (N) ELECTRICAL X X X X X X SCALE: 1" = 30'-0" 1 E1.2 1 E2.1 EXISTING CITY HALL BUILDING EXISTING BUILDING EXISTING LIBRARY EXISTING BEDWELL HALL FUTURE STORAGE BY OTHERS COMMUNITY STAGE SEE ENLARGED 2 E2.2 3 E2.2 CHILDREN PLAYGROUND FUTURE SPLASH PAD OUTDOOR FITNESS SKATE PARK BASKETBALL COURT TENNIS COURT BASEBALL FIELD 1 E2.2 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1183 of 1214 X X X 1E2.1 EXISTING CITY HALL BUILDING EXISTING BUILDING EXISTING LIBRARY EXISTING BEDWELL HALL FUTURE COMMUNITY STAGE CHILDREN PLAYGROUND FUTURE SPLASH PAD SKATE PARK BASEBALL FIELD BASKETBALL TENNIS OUTDOOR FITNESS CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
PHASE 1
PHASE 2
(N.I.C.)

FOR REFERENCE ONLY
PHASE 1 PHASE 2 PHASE 2 OVERALL ELECTRICAL SITE PLAN E1. 32 63 BID SET

Page 1213 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what'sbelow. Callbefore you dig.  ® PLAN NO. 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 Mechanical, Electrical and Plumbing
(MEP) Consulting Engineers
W:\WE-CA\Cudahy, City of\112093 - Cudahy Park\1200-Submittals\1204-100% PS&E\Electrical\Cudahy ELEC CAD Pack\ DWG: E2-1.dwg LAYOUT: Layout1 1:0.5 October 30, 2025 - 8:23 CUDAHY PARK RENOVATION PROJECT PHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201 ELECTRICAL SITE PLAN - WEST E2.1 A5P 60 A5P 60 A3P 60 A4P 60 A4P 60 A4P 60 A4P 60 A4P 60 A4P 60 A4P 60 A4P 60 A3P 60 A3P 60 A460 A3P 60 A3P 60 ELECTRICAL SITE PLAN - WEST SCALE: 1" = 20'-0" 1 E2.1 1186-ADA-2 Option Top View
(N) CONC. SLAB, PER
(N) ROLL-UP DOOR PANEL (N) STORAGE ROOM 600 SQ.FT.

STRUCTURAL DWG.
(N) ELECTRICAL 17&19 39&41 17&19 17&19 17&19 17&19 17&19 17&19 17&19 17&19 P-17&19 2"C-2#10 & 1#10 GRD. P-1&3, 5&7, 27&29 31&33 2"C-8#6 & 1#10 GRD. 1&35&7 P-9&11, 13&15, 14&16 2"C-6#6 & 1#10 GRD. 9&11 14&16 21&23 21&23 21&23 21&23 21&23 21&23 21&23 P-21&23 2"C-2#10 & 1#10 GRD. P2 2-410 P3 2-410 P1 2-410 P4 2-410 P-2&4, 6&8, 10&12 2"C-6#10 & 1#10 GRD. P12 2-410 P11 2-410 P10 2-410 NEW WEATHERPROOF MAIN SWITCHBOARD "NMS" SEE SINGLE LINE DIAGRAM AND ELEVATION DETAIL ON SHEET E4.1 EXISTING BEDWELL HALL CHILDREN PLAYGROUND FUTURE SPLASH PAD SKATE PARK OUTDOOR FITNESS EXISTING SCE POWER POLE WITH EXISTING LIGHTING EXISTING SCE POWER POLE WITH EXISTING LIGHTING 1 EXISTING LIGHT POLE NEW WATHERPROOF DISTRIBUTION BOARD 'NDB" AND TRANSFORMER "TI" NEW TUBULAR STEEL FENCE ENCLOSURE EXISTING CITY HALL BUILDING EXISTING BUILDING 2 2" C.O. FUTURE STORAGE BY OTHERS 4 10&12 6&8 2&4 4 77 7 7 7 7 7 LCPA P9 2-410 7 P6 2-410 P7 2-410 P5 2-410 P8 2-410 77 7 7 P-35&37, 39&41 2"C-4#6 & 1#10 GRD. 35&37 17&19 A6P 146 (TYP.) 8 10 SP 9 8 REFERENCE NOTES 1. 2"C-4#1/0 & 1#6 GRD. FOR SPLASH PAD TO DISTRIBUTION BOARD "NDB". (VERIFY SPLASH PAD EQUIPMENT ROOM LOCATION PRIOR TO INSTALLATION). SPLASH PAD PANEL AND EQUIPMENT INSTALLED BY OTHERS. 2. 2" C.O. STUB-UP WITH TAG AND CAP FOR FUTURE STORAGE PANEL TO DISTRIBUTION BOARD "NDB" BY OTHERS. 3. SEE MUSCO LIGHTING FIXTURE EQUIPMENT LIST ON SHEET E3.6. 4. EXISTING POLE LIGHT TO REMAIN. PROTECT IN PLACE AND CIRCUIT CONTINUITY AT ALL TIME. 5. DISCONNECT AND REMOVE EXISTING BASEBALL LAMP ON EXISTING LIGHTING POLE, REPLACE WITH NEW MUSCO LAMPS ON EXISTING LIGHTING POLE. MUSCO TO PROVIDE MATERIALS AND INSTALLATIONS. EXISTING LAMPS SHALL BE DELIVERED TO THE LOCATION DESIGNED BY THE CITY OR SHALL BE DISPOSED OF AS DIRECTED BY THE CITY. 6. INSTALL NEW BASEBALL FIELD LIGHTING FIXTURE PROVIDED BY MUSCO. MUSCO TO PROVIDE MATERIALS AND INSTALLATIONS. 7. VERIFY SPORT LIGHTING INSTALLATION WITH MANUFACTURER PRIOR TO ROUGH-IN THE MANUFACTURER SHALL PROVIDE CONCRETE BASE, SIZE AND PSI CALCULATION. 8. 2"C.O. STUB-UP WITH TAG AND CAP INSTALLED IN PULL BOX FOR FUTURE PHASE 2 CONSTRUCTION. LOCATE PULL BOX IN TURF AREA. 9. PANEL FOR SPLASH PAD PROVIDED AND CONNECTED BY OTHERS. 10. WEATHERPROOF 200AS/125AF, 3P DISCONNECT SWITCH FOR SPLASH PAD POWER "SP". PANEL PROVIDED AND CONNECTED BY OTHERS. # PRIOR TO COMMENCING THE ELECTRICAL WORK, THE CONTRACTOR SHALL CONTACT SOUTHERN CALIFORNIA EDISON (SCE) ASSIGNED PROJECT PLANNER TO OBTAIN SCE LATEST ELECTRICAL PLANS AND FOOR COORDINATION OF ELECTRICAL PERMIT AND SERVICE HOOK-UP. ELECTRICAL SERVICE POWER HOOK-UP TO MAIN SWITCHBOARD WILL BE ENERGIZED FROM EXISTING SCE TRANSFORMER LOCATED AT THE SANTA ANA ST. CITY HALL ENTRANCE. PLANNER: Laauli "Uli" Olotoa Planning Specialist Southern California Edison Local Planning | Compton District SCE Rules SCE Rates SCE Manuals [email protected] Cell: (310) 363-2044 SCE MANAGEMENT: Jessica Rubio Senior Planning Specialist T&D Dominguez Hills Service Center | Local Planning Cell: (626) 201-2056 Email: [email protected] 1924 E. Cashdan St. | Compton, CA 90220 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1184 of 1214 PHASE 1 PHASE 2 PHASE 2 (N.I.C.) PHASE 2 33 63 BID SET

Page 1214 of 1692 ends

PARK WALKWAY PHOTOMETRY PLAN SCALE: 1" = 30'-0" 1 E3.1 Luminaire Schedule Symbol Qty Label Arrangement LLF Description Lum. Watts Mtg Ht 9 A3 SINGLE 0.950 K206-P4FL-III-60(SSL)-7030 60 24 9 A4 SINGLE 0.950 K206-P4FL-IV-60(SSL)-7030 60.6 24 4 A5 SINGLE 0.950 K206-P4FL-V-60(SSL)-7030 60.1 24 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min SITE CALCS Illuminance Fc 1.12 2.4 0.2 5.60 12.00 A4 MH: 24.0 A4 MH: 24.0 A4 MH: 24.0 A4 MH: 24.0 A4 MH: 24.0 A4 MH: 24.0 A3 MH: 24.0 A4 MH: 24.0 A3 MH: 24.0 A4 MH: 24.0 A3 MH: 24.0 A5 MH: 24.0 A3 MH: 24.0 A4 MH: 24.0 1.7 1.2 0.6 0.5 0.5 0.6 0.9 1.5 1.7 2.1 1.9 1.6 1.3 1.0 0.8 0.8 1.0 1.2 1.6 2.0 2.3 2.0 1.8 1.2 0.8 0.7 0.6 0.5 0.4 0.4 0.4 0.6 0.8 1.3 1.7 2.2 2.1 1.7 1.2 0.9 0.8 0.8 0.9 1.1 1.7 2.1 2.4 1.9 1.6 1.2 1.1 1.0 1.2 1.0 0.5 0.9 1.7 1.9 1.7 1.2 0.7 0.5 0.4 1.0 1.1 0.9 0.5 0.8 1.6 1.8 1.9 1.5 1.0 1.2 1.2 0.9 0.7 1.1 1.4 1.7 1.6 1.3 0.8 1.6 1.5 1.0 1.2 1.1 2.0 1.8 1.4 1.0 1.0 2.1 1.9 1.0 1.2 1.3 1.8 2.2 2.1 0.6 1.1 1.5 1.0 1.1 1.4 1.7 2.0 2.2 2.4 0.2 1.1 1.7 1.0 1.1 1.3 1.6 1.9 2.0 1.9 1.6 1.5 1.4 2.0 0.3 1.8 0.8 0.9 0.9 1.0 1.1 1.3 1.5 1.8 1.8 1.6 1.2 1.2 1.4 1.7 1.8 0.4 0.4 0.9 1.0 1.0 1.0 1.2 1.4 1.8 1.8 1.2 1.1 0.8 1.0 0.5 0.5 0.5 0.5 1.1 1.1 1.1 1.2 1.5 0.9 0.9 0.9 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 0.6 0.6 0.6 0.7 0.9 1.1 1.2 1.5 1.1 1.2 1.1 0.8 0.7 0.7 1.1 1.2 1.2 1.2 1.1 1.1 1.1 1.2 1.5 0.8 0.8 0.8 0.8 0.8 1.0 1.1 1.6 2.0 1.1 1.0 0.8 0.8 0.8 0.8 0.8 1.2 1.3 1.3 1.2 1.1 1.1 1.2 1.3 1.6 1.8 1.7 1.3 1.0 0.9 0.8 0.8 0.8 0.9 1.1 1.5 1.8 1.8 1.1 0.8 0.8 0.8 0.8 0.7 0.9 1.2 1.3 1.3 1.2 1.1 1.1 1.2 1.3 1.5 1.5 1.5 1.5 1.2 1.1 1.0 0.8 0.8 0.9 1.0 1.3 1.4 1.4 1.4 0.8 0.8 1.1 1.5 1.4 1.4 1.2 1.1 1.1 1.2 1.2 1.3 1.4 1.5 1.5 1.4 1.3 1.1 0.9 0.8 0.8 0.9 1.0 1.1 1.2 1.3 0.9 0.8 1.3 1.5 1.5 1.4 1.2 1.1 1.1 1.1 1.2 1.3 1.3 1.4 1.5 1.4 1.3 1.2 1.0 0.9 0.8 0.9 0.9 1.0 1.0 1.2 1.2 1.5 1.3 0.9 0.8 1.0 1.3 1.3 1.2 1.2 1.1 1.1 1.2 1.3 1.4 1.4 1.5 1.5 1.5 1.4 1.3 1.1 0.9 0.9 0.9 0.9 0.9 1.0 1.1 1.1 1.1 1.2 1.4 1.6 1.3 1.0 0.7 0.6 0.8 1.0 1.0 1.0 1.0 1.1 1.1 1.3 1.6 1.6 1.5 1.6 1.7 1.6 1.6 1.4 1.2 1.0 0.9 0.9 0.9 0.9 1.0 1.0 0.9 0.8 0.8 0.6 0.8 0.9 0.9 0.9 1.1 1.1 1.4 1.7 1.7 1.5 1.6 1.7 1.7 1.8 1.6 1.3 1.0 1.0 1.0 1.0 1.0 1.0 0.9 0.7 0.7 0.6 0.5 0.6 0.8 0.8 0.9 1.0 1.1 1.4 1.8 1.7 1.4 1.3 1.5 1.8 1.9 1.7 1.3 1.1 1.1 1.1 1.1 1.1 1.0 0.8 0.7 0.4 0.4 0.5 0.6 0.7 0.7 0.8 0.9 1.0 1.0 0.9 0.9 0.9 1.2 1.6 1.5 1.3 1.2 1.1 1.1 1.2 1.1 1.0 0.8 0.7 0.9 1.1 1.2 1.2 1.2 1.3 1.3 1.1 0.9 0.7 0.6 0.8 1.0 1.1 1.2 1.5 1.5 1.1 0.9 0.7 0.5 0.6 0.7 0.9 1.1 1.4 1.4 1.0 0.8 0.6 0.3 0.4 0.4 0.5 0.5 0.6 0.6 0.4 0.4 0.3 1186-ADA-2 Option Top View
1186-ADA-2 Option Top View 1186-ADA-2 Option Top View
1186-ADA-2 Option Top View
1186-ADA-2 Option Top View 1186-ADA-2 Option Top View CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what'sbelow. Callbefore you dig.  ® PLAN NO. 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 Mechanical, Electrical and Plumbing (MEP) Consulting Engineers W:\WE-CA\Cudahy, City of\112093 - Cudahy Park\1200-Submittals\1204-100% PS&E\Electrical\Cudahy ELEC CAD Pack\ DWG: E3-1.dwg LAYOUT: Layout1 1:0.5 October 30, 2025 - 7:25 CUDAHY PARK RENOVATION PROJECT PHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201 PARK WALKWAY PHOTOMETRY PLAN FOR REFERENCE ONLY FOR REFERENCE ONLY E3.1 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1185 of 1214 PHASE 2 (N.I.C.) FOR REFERENCE ONLY PHASE 1 34 63 BID SET

Page 1215 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E3-2.dwg LAYOUT: Layout1 1:0.5 October 23, 2025 - 10:53:40AM stanley BASKETBALL & TENNIS COURT PHOTOMETRY PLAN & POLE DETAIL BASKETBALL & TENNIS COURT PHOTOMETRY PLAN SCALE: NONE 1 E3.2 12" Ø POLE 10" Ø POLE NOTE: MANUFACTURER SHALL PROVIDE INSTALLATION INSTRUCTION AND LIGHT POLE CONCRETE BASE STRUCTURE CALCULATION PER INSTALLATION LOCATION. CONCRETE BASE SHALL HAVE 6" ABOVE GRADE. LIGHTING MANUFACTURER'S CONTACT: AUDRA MASSEY PERFORMANCE LIGHTING SYSTEMS CELL: 951-741-8519 EMAIL: [email protected] FOR REFERENCE ONLY FOR REFERENCE ONLY E3.2 80.0000 A5P 60 A5P 60 A4P 60 A3P 60 A3P 60 A460 X X X XX X 17&19 17&19 17&19 17&19 17&19 17&19 17&19 P-1&3, 5&7 2"C-4#6 & 1#10 GRD. 5&7 14&16 23 21&23 3 P1P 3-400 P-2&4, 6&8, 10&12 2"C-6#10 & 1#10 GRD. P7 3-400 P6 SKATE PARK OUTDOOR FITNESS TENNIS COURT BASKETBALL COURT 6&8 2&4 B2 7135 B-2&4&6 1"C-4#6 & 1#10 GRD 7 7 7 7 6 3 1 2 3 4 6 5 8 7 9 10 11 12 14 13 16 15 17 18 22 23 24 25 26 27 67 72 67 61 57 55 57 60 65 71 75 69 63 59 61 63 64 64 71 74 69 65 68 73 72 67 63 59 62 59 58 61 64 62 57 53 65 64 61 59 60 64 72 76 75 67 69 69 67 65 67 73 79 78 64 71 74 74 69 67 70 78 76 51 54 64 67 62 58 59 65 64 59 61 57 58 63 68 64 56 53 71 74 68 65 70 75 76 73 66 71 75 70 66 64 68 71 70 68 67 71 68 62 59 59 62 65 66 55 59 63 65 62 59 62 66 66 65 69 73 74 69 67 72 79 79 65 64 63 61 60 65 73 80 79 66 60 57 56 58 64 71 77 75 78 81 78 70 64 60 60 63 67 81 86 81 73 68 67 68 67 68 79 83 79 74 75 80 79 74 69 63 66 64 63 65 68 67 62 58 65 64 63 62 63 68 74 73 64 69 71 72 71 69 72 76 78 68 71 76 79 79 74 72 74 77 66 58 61 70 72 66 62 61 62 54 66 70 67 68 73 78 74 64 60 79 85 80 77 78 83 82 78 73 82 86 82 76 73 74 74 73 70 79 81 79 72 66 64 64 65 65 60 64 69 69 65 62 63 63 55 70 75 79 79 73 73 76 77 68 68 67 66 65 66 70 77 79 67 66 62 59 59 62 67 74 73 63 26 42 38 35 39 44 32 26 25 41 47 41 37 40 43 36 49 52 25 46 52 45 36 32 32 32 33 46 49 32 38 51 48 37 30 27 25 26 32 43 43 29 50 53 42 33 28 25 24 26 35 48 50 29 41 43 39 37 31 25 24 29 39 50 53 26 49 44 33 26 25 31 40 41 28 35 35 27 23 24 29 37 31 2 7 4 3 3 23 5 4 23 6 3 3 10 3 2 4 9 19 21 15 10 7 5 6 6 5 4 2 1 1 11 11 4 3 2 2 1 1 1 1 17 4 2 1 1 1 1 1 0 12 4 2 1 1 1 0 0 0 9 5 2 1 1 1 0 0 0 0 1 1 5 5 5 0 2.5 2.5 2.5 2 15 18 20 22 23 24 24 24 24 24 25 25 24 25 25 24 23 22 21 20 16 19 21 23 24 26 27 27 27 26 26 25 25 24 24 24 23 22 21 19 8 12 9 26 35 36 36 39 41 39 37 36 36 37 37 39 40 40 39 13 9 7 12 9 7 6 8 7 7 6 8 7 6 6 6 CH:P1 MH:30' MH:30' CH:P2 CH:P3 MH:30' CH:P4 MH:30' CH:P5 MH:30' CH:P6 MH:30' CH:P7 MH:30' CH:P8 MH:30' CH:P9 MH:30' CH:P10 MH:30' CH:P11 MH:30' CH:P12 MH:30' CH:P13 MH:30' CH:P14 MH:30' CH:P15 MH:30' Badminton 1 Badminton 2 Badminton 3 Badminton 4 Badminton 5 Badminton 6 Badminton 7 Badminton 8 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1186 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
35 63 BID SET

Page 1216 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E3-3.dwg LAYOUT: Layout1 1:0.5 October 23, 2025 - 10:54:59AM stanley BASKETBALL & TENNIS COURT LIGHTING PHOTOMETRY & INSTALLATION DETAIL E3.3 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1187 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
36 63 BID SET

Page 1217 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY AS-NOTED PRE-001 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers SCJY P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E4-1.dwg LAYOUT: Layout1 1:0.5 October 30, 2025 - 3:07:32PM stanley SINGLE LINE DIAGRAM TO SCE UTILITY TRANSFORMER277/480V, 3Ø, 4W, 600 A BUS WEATHERPROOF MAIN SWITCHBOARD "NMS" 400A 3P 175A 3P350A 3P 225A 3P 150A 3P 120/208V, 3Ø, 4W, 400 A WEATHERPROOF DISTRIBUTION BOARD "NDB" PANEL "P" MUSCO LIGHTING CONTROL PANEL "B" REFERENCE NOTES 1. INDICATES PANEL SHALL BE AS SERVICE EQUIPMENT. THE GROUND BUS AND NEUTRAL BUS IN PANEL SHALL BE ISOLATED WITHOUT JUMPER. 2. PANEL FOR SPLASH PAD PROVIDED AND CONNECTED BY OTHERS. 3. WEATHERPROOF 200AS/125AF, 3P DISCONNECT SWITCH FOR SPLASH PAD PANEL "SP". PANEL PROVIDED AND CONNECTED BY OTHERS. 4. STUB-UP WITH TAG AND CAP FOR SPLASH PAD PANEL "SP". PANEL PROVIDED AND CONNECTED BY OTHERS. # 3-1/2"C-4#500 kcmil & 1#2 GRD. ±500', VD%=1.56% GROUND ROD 3/4"C-1#1/0 GRD. CU. (W.P.) 1 1-1/2"C-3#2/0 & 1#6 GRD. 112.5 KVA TRANSFORMER "T1" 480V-120/208V, 3Ø, 4W (BUILT-IN WITH "NDB". SEE ELEVATION TO LEFT) 1"C-1#1/0 GRD. CU. 3-1/2"C-4#500 kcmil & 1#2 GRD. 2-1/2"C-4#4/0 & 1#4 GRD. (PARK) 2" C.O. STUB-UP WITH TAG AND CAP FOR FUTURE STORAGE PANEL SPACE SINGLE LINE DIAGRAM SCALE: NONE 1 E4.1 91.50" 30.00" 30.00" 24.00" 91.50" 24.00" 42.00" 36.00" 24.00" 12.00" MAIN SWITCHBOARD ELEVATION DETAIL SCALE: NONE 3 E4.1 FINISHED GRADE CONCRETE PAD 12.00" WEATHERPROOF NEMA 3R ENCLOSURE WEATHERPROOF NEMA 3R ENCLOSURE WEATHERPROOF MAIN SWITCHBOARD "NMS" WEATHERPROOF DISTRIBUTION BOARD "NDB" AND TRANSFORMER "T1" (BASEBALL FIELD) 100A 3P PANEL "S" 2"C-4#1 & 1#8 GRD. ±380'; VD=0.41% 95% COMPACTED SUB-GRADE GROUND ROD 3/4"C-1#8 GRD. CU. (1) 2"C.O. STUB-UP WITH TAG AND CAP FOR WATER FEATURE OF BEDWELL HALL (V.L.) (W.P. COMM. STAGE) NOTE: SEE CIVIL DRAWING FOR MORE DETAILS MAIN 400A 3P Relay Circuit Description Switch/Sensor 1234567 LCPA CONDUIT AND CONDUCTORS TO CONTROLLED LIGHTING AND POWER CIRCUITS, ALSO INCLUDE UN-SWITCHED HOT CIRCUIT CONDUIT AND CONDUCTORS ARE REQUIRED FOR LIGHTING AND POWER CIRCUIT "P" PANEL LCP ID: LCPA LOCATION: NEXT PANEL "NDB" SUPPLY CIRCUIT: GREENGATE #CKT-XX 365 PROGRAMMABLE LIGHTING CONTROL PANEL APPROVED BY CALIFORNIA ENERGY COMMISSION P-1&3 BASKETBALL COURT LTG. TIME CLOCK P-5&7 BASKETBALL COURT LTG. TIME CLOCK P-9&11 TENNIS COURT LTG. TIME CLOCK P-13&15 TIME CLOCK P-17&19 TIME CLOCK P-21&23 TIME CLOCK TENNIS COURT LTG. PARK WALKWAY LTG. PARK WALKWAY LTG. 89101112131415 P-2&4 P-6&8 P-10&12 P-14&16 16 SKATE PARK LTG. SKATE PARK LTG. SKATE PARK LTG. SKATE PARK LTG. TIME CLOCK TIME CLOCK TIME CLOCK TIME CLOCK LIGHTING CONTROL WIRING DIAGRAM SCALE: NONE 2 E4.1 Comment 12.00" E4.1 125A 3P PANEL "SP" 2"C-4#1/0 & 1#6 GRD. F 34 2 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1188 of 1214 CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
37 63 BID SET

Page 1218 of 1692 ends

CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY AS-NOTED PRE-001 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig. ® PLAN NO. SEJ IC U HE Y A M. REGISTERED PROFESS IONAL ENGINEER STATE OF CAL I FORN IA E L E C T R I C A L 1303 West Roxbury Street (626) 337-1965 / JOB #24-2502 West Covina, California 91790-4618 MY Engineering, Inc. Mechanical, Electrical and Plumbing (MEP) Consulting Engineers SCJY P:\Drawings\!-CA Projects\24-2502 Cudahy Park Renovation\24-2502 ELEC DWGS\ DWG: E4-2.dwg LAYOUT: Layout1 1:0.5 October 30, 2025 - 3:07:56PM stanley PANEL AND FIXTURE SCHEDULES E4.2 PANEL SCHEDULE FOR SPLASH PAD "SP" PROVIDED BY SPLASH PAD VENDOR (FOR REFERENCE ONLY) Cudahy Park Renovation Project, Project # PRE-001 Document Control 1189 of 1214 PHASE 2 (N.I.C.) FOR REFERENCE ONLY PHASE 2 (N.I.C.) FOR REFERENCE ONLY PHASE 2 (N.I.C.) FOR REFERENCE ONLY PHASE 2 (N.I.C.) FOR REFERENCE ONLY CUDAHY PARK RENOVATION PROJECT PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
38 63 BID SET

Page 1219 of 1692 ends

CANTILEVERED CURVED GRIND OUT LEDGE CURVED SLAPPY CURB QUARTERPIPE EXTENSION QUARTERPIPE ROLLOVER RAINBOW RAIL ROUND SLAPPY GRIND RAIL INSET SLAPPY MANUAL PAD LA HIGH WALL QUARTERPIPE EXTENSION ROLL-IN QUARTERPIPE ROLL-IN ROLLOVER CURVED QUARTERPIPE EXTENSION ROLL-IN 3D PERSPECTIVE ROLL-IN ROLL-IN CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.SK1.0 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1190 of 1214 SKATEPARK 44 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
39 63

Page 1220 of 1692 ends

3D PERSPECTIVE SK1.1 CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1191 of 1214 SKATEPARK

ROLLOVER

QUARTERPIPE QUARTERPIPE

EXTENSION
CURVED

SLAPPY CURB CANTILEVERED

CURVED GRIND

OUT LEDGE ROLL-IN

GROUNDSLAPPY GRIND

RAINBOW RAIL RAIL

INSET SLAPPYMANUAL PAD

LA HIGH WALL

ROLL-IN

ROLL-IN

QUARTERPIPEEXTENSION
CURVED

QUARTERPIPE

EXTENSION

ROLL-IN

ROLL-IN

ROLL-IN

QUARTERPIPE

ROLLOVER
45 BID SET
CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
40 63

Page 1221 of 1692 ends

1-800-227-2600 CA SPECIFICATIONS CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.SK2.0 GENERAL NOTES DESIGN CRITERIA 1. THESE GENERAL NOTES APPLY UNLESS NOTED OTHERWISE ON CONSTRUCTION DRAWINGS. 2. COMPLY WITH CURRENT LOCAL BUILDING CODE EXCEPT AS NOTED HEREIN. 3. TESTING SERVICES: OWNER TO BEAR ALL ASSOCIATED COSTS FOR TESTING SERVICES. COORDINATE THE FOLLOWING TESTING WITH THE OWNER SELECTED TESTING AGENCY (IF REQUIRED BY THE PROJECT SPECIFICATIONS): A. MATERIAL EVALUATIONS TESTS FOR CONCRETE MIX, AGGREGATE BASE, SUBGRADE, AND STRUCTURAL FILL. B. INSPECTION OF STRUCTURAL FILL PLACEMENT AND COMPACTION. C. INSPECTION OF FINAL SUBGRADE. D. BASE MATERIAL COMPACTION TEST FOR EVERY 2500 S.F. OF CONCRETE FLATWORK IN SKATEPARK AREA TO ENSURE 90% COMPACTION IN ACCORDANCE WITH CIVIL ENGINEERING SPECIFICATIONS AND TESTING AGENCY RECOMMENDATIONS. SHOP DRAWINGS 1. THE SHOP DRAWING REVIEW IS INTENDED TO HELP THE SKATEPARK DESIGNER VERIFY THEIR DESIGN CONCEPT. THIS REVIEW IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AND DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH DESIGN DRAWINGS & SPECIFICATIONS, WHICH HAVE A PRIORITY OVER SHOP DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR CONFIRMED & CORRELATED DIMENSIONS, FABRICATION PROCESSES, MEANS, METHODS, TECHNIQUES, SAFETY, AND COORDINATION OF THE WORK WITH OTHER TRADES. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CHECK THE ACCURACY OF HIS OWN SHOP DRAWINGS AND THOSE OF HIS SUBCONTRACTORS, PRIOR TO SUBMITTAL. 2. THE SHOP DRAWINGS WILL BE RETURNED FOR RESUBMITTAL IF A CURSORY REVIEW SHOWS MAJOR ERRORS WHICH SHOULD HAVE BEEN FOUND BY THE CONTRACTOR'S CHECKING. ALL SHOP DRAWINGS SHALL INCLUDE PLAN LAYOUTS SHOWING LOCATIONS OF ITEMS DETAILED ON THE SHOP DRAWINGS. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM THE CONTRACT DOCUMENTS SHALL BE CLOUDED ON SHOP DRAWINGS. ANY OF THE CHANGES WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED REVIEWED AFTER SKATEPARK DESIGNER'S REVIEW UNLESS NOTED ACCORDINGLY. 3. ANY RESUBMITTAL OF A DETAIL SHEET WITH CHANGED INFORMATION SHALL BE ACCOMPANIED BY LOCATION PLAN IDENTIFYING THE MEMBERS INVOLVED, AND CLOUDING AROUND CHANGED INFORMATION. 4. ANY ENGINEERING SUBMITTED FOR REVIEW SHALL BE APPROPRIATELY SEALED. FULL RESPONSIBILITY OF SUCH ENGINEERING RESTS WITH THE PERSON SEALING THE DESIGN. EARTHWORK 1. ESTABLISH AND MAINTAIN REQUIRED LINES AND GRADE ELEVATIONS. 2. REMOVE UPPER FOUR TO SIX INCHES OR MORE OF TOPSOILS CONTAINING SURFICIAL VEGETATION, GRASS, ROOTS, AND ORGANIC MATERIAL FROM WITHIN AND TO A POINT AT LEAST FIVE FEET BEYOND THE BUILDING LINES/SKATEPARK LIMITS. THESE SOILS ARE GENERALLY NOT CONSIDERED SUITABLE FOR RE-USE AS STRUCTURAL FILL AND SHOULD BE STOCKPILED IN DESIGNATED AREAS BEYOND THE CONSTRUCTION LIMITS, OR REMOVED FROM THE SITE. COORDINATE STOCKPILE LOCATION WITH OWNER. IF REMOVED FROM SITE, DISPOSE OF IN A LEGAL MANNER. 3. COMPACT THE EXPOSED SUBGRADE ACROSS THE SITE TO ESTABLISH A FIRM AND UNYIELDING SURFACE. UNDER SUPERVISION OF CITY PROVIDED GEOTECHNICAL ENGINEER, PROOF-ROLL EXPOSED SUBGRADES WITH CONSTRUCTION EQUIPMENT TO ASSIST IN THE EVALUATION OF THE SUBGRADES ACROSS THE SITE. IF UNSTABLE AREAS ARE DETECTED, AN INITIAL ATTEMPT SHOULD BE MADE TO AERATE (12 INCHES MIN.) AND DENSIFY THE SUBGRADE BY RECOMPACTION WHERE NATURAL MOISTURE CONTENTS ARE AT APPROPRIATE LEVELS. IF THIS PROCEEDURE IS INEFFECTIVE, THE DISTURBED SOILS SHOULD BE UNDERCUT AND REPLACED WITH CLEAN FILL AND/OR STABILIZING MATERIALS. COMPACT TO AT LEAST 90% OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698 STANDARD PROCTOR METHOD. FILL AND CONSOLIDATE DEPRESSED AREAS. A FIRM, NON-YIELDING SUBGRADE SHOULD BE ESTABLISHED PRIOR TO PROCEEDING WITH FILL PLACEMENT. 4. SOIL COMPACTION SHALL BE ACHIEVED BY MEANS OF PNEUMATIC TIRE ROLLERS, HOE PACKS, RIDE-ON DRUM ROLLER OR OTHER MECHANICAL TAMPERS (PLATE, RAMMER, OR WALK BEHIND ROLLER). 5. PROVIDE STRUCTURAL FILL AS REQUIRED TO MEET PROPOSED SUBGRADE ELEVATIONS IN ACCORDANCE WITH GRADING PLAN. 6. BUILD UP SUBGRADE USING STOCKPILED MATERIAL AND/OR APPROVED MATERIAL WITH LOW PLASTICITY. THE FILL SHOULD BE PLACED IN LIFTS THIN ENOUGH TO ATTAIN THE SPECIFIED COMPACTION LEVEL THROUGHOUT THE ENTIRE LIFT THICKNESS. PRIOR TO COMPACTION, MOISTURE CONDITION AS NEEDED. COMPACT EACH LIFT TO AT LEAST 90 PERCENT OF ASTM D698. 7. THE EARTHWORK SHALL BE DONE UNDER SUPERVISION OF A SOILS ENGINEER RETAINED BY THE OWNER (IF REQUIRED BY THE PROJECT), WHO SHALL VERIFY ABOVE SPECIFICATIONS FOR THE SUPPORT OF SLAB ON GRADE AND FOR THE CONTROL OF SOIL SWELLING. FIELD DENSITY TESTS TO DETERMINE THE LEVEL OF COMPACTION BEING ACHIEVED IN THE FILL SHALL BE PERFORMED ON EACH LIFT AT THE BEGINNING OF FILL PLACEMENT AND AT A FREQUENCY MUTUALLY AGREED UPON BY THE PROJECT TEAM FOR THE REMAINDER OF THE PROJECT. 8. EXCAVATION AND COMPACTION OF FILL SHALL EXTEND TO MINIMUM 2' FEET BEYOND SKATE PARK FOOTPRINT. 10. PROCEED WITH SUB-BASE AS REQUIRED ONLY AFTER NONCONFORMING CONDITIONS HAVE BEEN CORRECTED AND SUBGRADE HAS BEEN INSPECTED. A FIRM, NON-YIELDING SUBGRADE SHOULD BE ESTABLISHED PRIOR TO BASE COURSE PLACEMENT. 11. PROVIDE THE SPECIFIED DEPTH OF COMPACTED AGGREGATE BASE MATERIAL IF REQUIRED. COMPACT AGGREGATE BASE TO 90% OF THE MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698 STANDARD PROCTOR METHOD IF REQUIRED. 12. PROCEED WITH CONCRETE ONLY AFTER NONCONFORMING CONDITIONS HAVE BEEN CORRECTED, SUBGRADE HAS BEEN INSPECTED, AND FORMWORK AND FIELD MOCK-UPS HAVE BEEN REVIEWED. 13. A SOILS REPORT DOES EXIST FOR THIS PROJECT. OWNER SHALL RETAIN A SOILS ENGINEER IF SO REQUIRED BY THE PROJECT, TO VERIFY EXCAVATIONS FOR ASSUMED ALLOWABLE SOIL BEARING, LOW SETTLEMENT AND SWELL POTENTIAL, AND TO MAKE ANY ADDITIONAL RECOMMENDATIONS. FORMS 1. FORM MATERIALS: PLYWOOD, METAL, METAL-FRAMED PLYWOOD, OR OTHER APPROVED PANEL-TYPE MATERIALS FREE FROM DEFECTS AND DISTORTION, AND TO PROVIDE FULL-DEPTH, CONTINUOUS, STRAIGHT, SMOOTH EXPOSED SURFACES. 2. USE FLEXIBLE OR CURVED FORMS AS REQUIRED TO PROVIDE VERTICAL AND HORIZONTAL RADII AS INDICATED IN THE DRAWINGS. 3. PROVIDE 2” NOMINAL THICKNESS, SURFACED PLANK WOOD FORMS FOR STRAIGHT SECTIONS. USE FLEXIBLE METAL, 1” LUMBER, OR PLYWOOD FORMS FOR RADIUS BENDS. DO NOT OVERLAP FORMS, CREATING AN OFFSET FINISHED EDGE. 4. FORM-RELEASE AGENT: COMMERCIALLY FORMULATED FORM-RELEASE AGENT THAT WILL NOT BOND WITH, STAIN, OR ADVERSELY AFFECT CONCRETE SURFACES AND WILL NOT IMPAIR SUBSEQUENT TREATMENTS OF CONCRETE SURFACES. 5. EDGE FORMS AND SCREED CONSTRUCTION A. SET, BRACE, AND SECURE EDGE FORMS, BULKHEADS, AND INTERMEDIATE SCREED GUIDES FOR PAVEMENT TO REQUIRED LINES, GRADES, AND ELEVATIONS. INSTALL FORMS TO ALLOW CONTINUOUS PROGRESS OF WORK. B. CLEAN FORMS AFTER EACH USE AND COAT WITH FORM RELEASE AGENT TO ENSURE SEPARATION FROM CONCRETE WITHOUT DAMAGE. REINFORCING 1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60. FOR REINFORCING THAT IS TO BE WELDED, CONFORM TO ASTM A706 GRADE 60. USE ASTM A-108 GRADE 60 FOR ALL WELDED ANCHORS. 2. JOINT DOWEL BARS: PLAIN STEEL DOWELS, ASTM A 615/A 615M, GRADE 60. CUT BARS TRUE TO LENGTH WITH ENDS SQUARE AND FREE OF BURRS. 3. SLIP DOWEL SLEEVES ARE ACCEPTABLE, SUCH AS SPEED DOWELS BY GREENSTREAK, INC., OR APPROVED EQUAL. 4. BAR SUPPORTS: BOLSTERS, CHAIRS, SPACERS AND OTHER DEVICES FOR SPACING, SUPPORTING, AND FASTENING REINFORCEMENTS BARS, AND DOWELS IN PLACE. MANUFACTURE BAR SUPPORTS ACCORDING TO CRSI'S “MANUAL OF STANDARD PRACTICE” FROM STEEL WIRE, PLASTIC, OR PRECAST CONCRETE OR FIBER-REINFORCED CONCRETE OF GREATER COMPRESSIVE STRENGTH THAN CONCRETE. 5. ALL REINFORCING BARS TO BE DEFORMED. CLEAR CONCRETE COVERAGES TO ANY REINFORCING INCLUDING TIES ARE AS FOLLOWS: A. 2" FORMED CONCRETE EXPOSED TO EARTH OR WEATHER. B. 1" SLABS AND JOISTS NOT EXPOSED TO WEATHER. C. 1-1/2" ALL OTHER. 6. SMALLER CLEARANCES PERMISSIBLE FOR PRECAST OR PRESTRESSED. 7. TENSION LAP SPLICES IN CONCRETE: UNLESS NOTED OTHERWISE, PROVIDE THE FOLLOWING: A. #3, 9"; #4, 12". 30X DIAMETER FOR TOP BARS 8. MINIMUM CLEAR COVER FOR SPLICED REINFORCING IS GREATER THAN ONE BAR DIAMETER, AND MINIMUM CLEAR SPACING IS GREATER THAN TWO BAR DIAMETERS. SPLICE BOTTOM BAR OVER SUPPORTS AND TOP BAR AT MIDSPAN ONLY. WHERE BARS ARE SHOWN SPLICED, THEY MAY RUN CONTINUOUS AT CONTRACTOR'S OPTION. CONCRETE 1. PROVIDE MIX DESIGNS THAT WILL MEET THE MINIMUM REQUIREMENTS LISTED HEREIN: A. MINIMUM 28-DAY STRENGTH: 4000 PSI B. TYPE I/II/IL CEMENT C. SMALL TO MEDIUM AGGREGATE (1" MAX.) D. WATER/CEMENT RATIO OF .45 OR LESS E. MIX DESIGNS CONTAINING FLY ASH: THE AMOUNT OF FLY ASH USED SHALL NOT EXCEED 20% BY WEIGHT OF THE COMBINED WEIGHT OF FLY ASH PLUS CEMENT. F. AIR ENTRAINMENT NOT TO EXCEED 3%. 2. DO NOT INSTALL CONCRETE WORK OVER SATURATED, MUDDY, OR FROZEN SUBGRADE. 3. PROTECT ADJACENT WORK AND PROVIDE TEMPORARY BARRICADES AS REQUIRED FOR PROTECTION OF PROJECT WORK AND PUBLIC SAFETY. 4. MECHANICALLY VIBRATE ALL CONCRETE FLATWORK WHEN PLACED, EXCEPT THAT SLABS ON GRADE AND SLABS ON DECK NEED TO BE VIBRATED ONLY AROUND EMBEDDED ITEMS. 5. CONCRETE CYLINDERS SHALL BE TAKEN AND TESTED PER THE ACI CODE, WHEN REQUIRED BY THE PROJECT. FREQUENCY= 1 SET OF CYLINDERS PER 50 CY'S PLACED. OWNER TO BEAR ALL COSTS. 6. ALL REINFORCING, INCLUDING DOWELS AND ANCHOR BOLTS, SHALL BE SECURELY TIED IN LOCATION BEFORE PLACING CONCRETE OR GROUT. DOWELS WILL NOT BE ALLOWED TO BE "STABBED" IN. 7. IN AN EFFORT TO CONTROL SHRINKAGE AND QUALITY, FLATWORK/FLOORS SHOULD BE PLACED IN SECTIONS OF 25 CY’S OR LESS. 8. CONDUITS, PIPES, AND SLEEVES EMBEDDED IN CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 6.3. CONCRETE PLACEMENT 1. CONSOLIDATE CONCRETE BY MECHANICAL VIBRATING EQUIPMENT SUPPLEMENTED BY HAND-SPADING, RODDING OR TAMPING. USE EQUIPMENT AND PROCEDURES TO CONSOLIDATE CONCRETE ACCORDING TO RECOMMENDATIONS IN ACI 309R. A. CONSOLIDATE CONCRETE ALONG FACE OF FORMS AND ADJACENT TO TRANSVERSE JOINTS WITH AN INTERNAL VIBRATOR. KEEP VIBRATOR AWAY FROM JOINT ASSEMBLIES, REINFORCEMENT, OR SIDE FORMS. USE ONLY SQUARE-FACED SHOVELS FOR HAND-SPREADING AND CONSOLIDATION. CONSOLIDATE WITH CARE TO PREVENT DISLOCATING REINFORCEMENT, DOWELS, AND JOINT DEVICES. 2. COLD WEATHER PLACEMENT: COMPLY WITH ACI 306.1 AND AS FOLLOWS. PROTECT CONCRETE WORK FROM PHYSICAL DAMAGE OR REDUCED STRENGTH THAT COULD BE CAUSED BY FROST, FREEZING ACTIONS, OR LOW TEMPERATURES. A. WHEN AIR TEMPERATURE HAS FALLEN TO OR IS EXPECTED TO FALL BELOW 40 DEG F, UNIFORMLY HEAT WATER AND AGGREGATES BEFORE MIXING TO OBTAIN A CONCRETE MIXTURE TEMPERATURE OF NOT LESS THAN 50 DEG F AT POINT OF PLACEMENT. B. DO NOT USE FROZEN MATERIALS OR MATERIALS CONTAINING ICE OR SNOW. C. DO NOT USE CALCIUM CHLORIDE, SALT, OR OTHER MATERIALS CONTAINING ANTIFREEZE AGENTS OR CHEMICAL ACCELERATORS, UNLESS OTHERWISE SPECIFIED AND APPROVED IN MIX DESIGNS. 3. HOT-WEATHER PLACEMENT: PLACE CONCRETE ACCORDING TO RECOMMENDATION IN ACI 305R AND AS FOLLOWS WHEN HOT-WEATHER CONDITIONS EXIST: A. COOL INGREDIENTS BEFORE MIXING TO MAINTAIN CONCRETE TEMPERATURE AT TIME OF PLACEMENT BELOW 100 DEG FAHRENHEIT. CHILLED MIXING WATER OR CHOPPED ICE MAY BE USED TO CONTROL TEMPERATURE, PROVIDED WATER EQUIVALENT OF ICE IS CALCULATED TO TOTAL AMOUNT OF MIXING WATER. USING LIQUID NITROGEN TO COOL CONCRETE IS CONTRACTORS OPTION. B. FOG-SPRAY FORMS, REINFORCEMENT STEEL, AND SUBGRADE JUST BEFORE PLACING CONCRETE. KEEP SUBGRADE MOISTURE UNIFORM WITHOUT STANDING WATER, SOFT SPOTS, OR DRY AREAS. 4. FINISH: ALL EXPOSED CONCRETE SURFACES ARE TO BE HARD STEEL TROWEL FINISH UNLESS OTHERWISE NOTED. TROWEL UNTIL ALL VISIBLE PORES ARE CLOSED. CEASE TROWELING BEFORE SURFACE BECOMES GLOSSY. DO NOT BROOM FINISH AND DO NOT TROWEL BURN SURFACE. a. ALL EDGE TOOLING SHOULD BE 1/8 INCH RADIUS UNLESS OTHERWISE SPECIFIED. 5. COLOR: ALL CONCRETE SURFACES ARE TO BE NATURAL GRAY COLOR UNLESS OTHERWISE NOTED. MINOR VARIATIONS IN APPEARANCE OF COLORED CONCRETE, WHICH ARE SIMILAR TO NATURAL VARIATIONS IN COLOR AND APPEARANCE OF UNCOLORED CONCRETE, ARE ACCEPTABLE. DO NOT BROOM FINISH AND DO NOT TROWEL BURN SURFACE. CONCRETE PROTECTION AND CURING 1. GENERAL: PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. COMPLY WITH ACI 306.1 FOR COLD-WEATHER PROTECTION AND FOLLOW RECOMMENDATIONS IN ACI 305R FOR HOT-WEATHER PROTECTION DURING CURING. KEEP MOIST FOR NECESSARY AMOUNT OF TIME TO REACH CONCRETE STRENGTH AND INHIBIT MOISTURE LOSS AFTER PLACING. 2. EVAPORATION RETARDANT: WATERBORNE, MONOMOLECULAR FILM FORMING, MANUFACTURED FOR APPLICATION TO FRESH CONCRETE, SUCH AS EUCOBAR EVAPORATION RETARDANT BY THE EUCLID CHEMICAL COMPANY. APPLY EVAPORATION RETARDANT TO CONCRETE SURFACES IF HOT, DRY, OR WINDY CONDITIONS CAUSE MOISTURE LOSS BEFORE AND DURING FINISHING OPERATIONS. APPLY TO EXPOSED SURFACE OF CONCRETE ACCORDING TO MANUFACTURERS WRITTEN INSTRUCTIONS AS NECESSARY. 3. BEGIN CURING AFTER FINISHING CONCRETE, BUT NOT BEFORE FREE WATER HAS DISAPPEARED FROM CONCRETE SURFACE. 4. CURING METHODS: CURE CONCRETE BY CURING COMPOUND, MOISTURE CURING, MOISTURE-RETAINING-COVER CURING, OR A COMBINATION OF THESE AS FOLLOWS: A. CURING COMPOUND: MEET REQUIREMENTS OF MANUFACTURER’S CURRENT PRINTED APPLICATION INSTRUCTIONS AND COVERAGE RATE CHART. FOR HORIZONTAL APPLICATIONS, IMMEDIATELY APPLY AFTER ALL SURFACE WATER HAS DISAPPEARED AND THE CONCRETE SURFACE IS HARD ENOUGH TO WALK ON. FOR VERTICAL APPLICATIONS, APPLY IMMEDIATELY AFTER REMOVING THE CONCRETE FORMS. APPLY IN A UNIFORM AND CONTINUOUS MANNER. AVOID OVER-APPLICATION OR PUDDLING OF CURING COMPOUND. PROTECT SURFACE FROM WATER, ADJACENT SHOTCRETE WORK, AND DEBRIS. B. MOISTURE CURING: KEEP SURFACES CONTINUOUSLY MOIST FOR NOT LESS THAN SEVEN DAYS WITH THE FOLLOWING MATERIALS: · WATER. · CONTINUOUS WATER-FOG SPRAY. · ABSORPTIVE COVER, WATER SATURATED, AND KEPT CONTINUOUSLY WET. COVER CONCRETE SURFACES AND EDGES, OVERLAP SEAMS MIN. 6" BETWEEN ADJACENT ABSORPTIVE COVERS. C. MOISTURE-RETAINING-COVER CURING: COVER CONCRETE SURFACES WITH MOISTURE-RETAINING COVER FOR CURING CONCRETE, PLACED IN WIDEST PRACTICABLE WIDTH, WITH SIDES AND ENDS LAPPED AT LEAST 6 INCHES. CURING MATERIALS 1. ABSORPTIVE COVER: AASHTO M 182, CLASS 2, BURLAP CLOTH MADE FROM JUTE OR KENAF, WEIGHING APPROXIMATELY 9OZ./SQ. YD. DRY. 2. MOISTURE-RETAINING COVER: ASTM C 171, POLYETHYLENE FILM OR WHITE BURLAP-POLYETHYLENE SHEET (BUR LENE). 3. WATER: POTABLE. 4. CURING COMPOUND: ASTM C-309, CLEAR, WATER-BASED, NO VOLATILE, NON-STAINING, MEMBRANE-FORMING, COMPATIBLE WITH SUBSEQUENT CONCRETE TREATMENTS. ACCEPTABLE PRODUCT: W.R. MEADOWS 1100-CLEAR, OR APPROVED EQUAL. JOINT MATERIALS 1 EXPANSION AND ISOLATION JOINT FILLER STRIPS: EXPANSION JOINT MATERIALS SHALL BE FLEXIBLE POLYETHYLENE CLOSED CELL FOAM OR SIMILAR AND SUPPLIED BY CONCRETE CONTRACTOR. DECK-O-FOAM OR EQUIVALENT. 2 EXPANSION JOINT SEALANT: SIKAFLEX - 1A NS TG POLYURETHANE ELASTOMERIC SEALANT, OR APPROVED EQUAL. COLOR OF CAULK SHOULD RESEMBLE NATURAL COLOR OF CONCRETE (ALUMINUM GRAY OR LIMESTONE). 3 SAW CUT JOINT SEALANT: SIKAFLEX-1C SL HIGH PERFORMANCE, SELF-LEVELING, 1-PART POLYURETHANE SEALANT, OR APPROVED EQUAL. COLOR OF CAULK SHOULD RESEMBLE NATURAL COLOR OF CONCRETE (ALUMINUM GRAY OR LIMESTONE) JOINTS 1. GENERAL: CONSTRUCT CONSTRUCTION, ISOLATION, AND CONTRACTION JOINTS AND TOOL EDGINGS TRUE TO LINE WITH FACES PERPENDICULAR TO SURFACE PLANE OF CONCRETE. CONSTRUCT TRANSVERSE JOINTS AT RIGHT ANGLES TO CENTERLINE, UNLESS OTHERWISE INDICATED. 2. EXPANSION JOINTS: FORM EXPANSION JOINTS OF SPECIFIED JOINT-FILLER STRIPS WHERE INDICATED A. LOCATE EXPANSION JOINTS AS INDICATED ON DRAWINGS. B. EXTEND JOINT FILLERS FULL WIDTH AND DEPTH OF JOINT. 3. INSTALL DOWEL BARS AND SUPPORT ASSEMBLIES AT JOINTS WHERE INDICATED. LUBRICATE OR ASPHALT-COAT ONE-HALF DOWEL LENGTH TO PREVENT CONCRETE BONDING TO ONE SIDE OF JOINT. 4. CONTROL JOINTS: FORM WEAKENED-PLANE JOINTS, SECTIONING CONCRETE INTO AREAS AS INDICATED. CONSTRUCT CONTROL JOINTS FOR A DEPTH AS INDICATED IN THE DRAWINGS (GENERALLY 1/3 OF THE PAVEMENT THICKNESS), AS FOLLOWS: A. SAWED JOINTS: FORM CONTROL JOINTS WITH POWER SAWS EQUIPPED WITH SHATTERPROOF ABRASIVE OR DIAMOND-RIMMED BLADES. CUT 1/8 INCH WIDE JOINTS INTO CONCRETE WHEN CUTTING ACTION WILL NOT TEAR, ABRADE, OR OTHERWISE DAMAGE SURFACE AN BEFORE DEVELOPING RANDOM CONTRACTION CRACKS. EARLY SAW CUTS ARE APPROXIMATELY 1 INCH DEEP, REGARDLESS OF PAVEMENT THICKNESS. REFER TO CONTROL JOINT GUIDE DRAWING OF PLAN SET IF APPLICABLE. B. IF SKATEPARK PROJECT DESIGN UTILIZES POURED STEPS, CONTROL JOINTS MUST BE CUT 3 - 4 FEET FROM THE EDGE OF THE TOP STEP. 5. POST CURE DETAIL WORK (AS NEEDED): GRIND SMOOTH ANY INCONSISTENCIES IN THE FINISH OR HIGH SPOTS BETWEEN POURS. METALS 1. FURNISH MATERIALS AND PERFORM LABOR REQUIRED TO EXECUTE THIS WORK AS INDICATED ON THE DRAWINGS, AS SPECIFIED, AND AS NECESSARY TO COMPLETE THE CONTRACT, INCLUDING, BUT NOT LIMITED TO BOWL STEEL COPING, LEDGE STEEL EDGING, HANDRAILS, AND GRIND RAILS. 2. USING SKILLED WORKERS, FORM AND FABRICATE ITEMS OF WORK AS INDICATED AND AS REQUIRED TO MEET INSTALLATION CONDITIONS. MAKE PROVISIONS TO CONNECT WITH OR RECEIVE THE WORK OF OTHER TRADES. 3. USE MATERIALS OF SIZE AND THICKNESS SHOWN OR, IF NOT SHOWN, OF REQUIRED SIZE AND THICKNESS TO PRODUCE STRENGTH AND DURABILITY IN THE FINISHED PRODUCT. 4. UNLESS OTHERWISE INDICATED, WELD OR BOLT CONNECTIONS BETWEEN MEMBERS. WHERE POSSIBLE, CONCEAL CONNECTIONS ON THE FINISHED WORK. FIT OR MITER EXPOSED JOINTS TO HAIRLINE TOLERANCE OR USE WELDED JOINTS. ON FINISHED SURFACES, GRIND ALL WELDS SMOOTH AND FLUSH WITH BASE METAL. 5. WELD CONNECTIONS WHICH ARE NOT TO BE LEFT AS EXPOSED JOINTS, BUT CANNOT BE SHOP WELDED BECAUSE OF SHIPPING SIZE LIMITATIONS. 6. CAP ALL EXPOSED TUBE OR PIPE ENDS. USE SIZE AND THICKNESS OF MATERIAL SHOWN. PROPERLY FIT AND WELD CAP AT JOINT, GRIND WELD SMOOTH AND FLUSH WITH BASE METAL. 7. BEND PIPE OR TUBING WITHOUT COLLAPSING OR DEFORMING THE WALLS, SO AS TO PRODUCE A SMOOTH UNIFORM CURVED SECTION AND MAINTAIN UNIFORM SECTIONAL SHAPE. 8. WHERE ITEMS ARE TO BE IMBEDDED IN CONCRETE OR MASONRY, PROVIDE WELDED-ON ANCHORS OR LUGS AS INDICATED OR REQUIRED. 9. PROVIDE TEMPORARY BRACING OR ANCHORS IN FORMWORK FOR ITEMS WHICH ARE TO BE BUILT INTO CONCRETE OR SIMILAR CONSTRUCTION. 10. FASTENING TO IN-PLACE CONSTRUCTION: PROVIDE ANCHORING DEVICES AND FASTENERS WHERE NECESSARY FOR SECURING MISCELLANEOUS METAL FABRICATIONS TO IN-PLACE CONSTRUCTION INCLUDING THREADED FASTENERS FOR CONCRETE INSERTS, OR OTHER CONNECTORS AS REQUIRED. 11. GALVANIZING REPAIR--USE A HIGH ZINC DUST CONTENT PAINT FOR RE-GALVANIZING WELDS IN GALVANIZED STEEL. HOT GALVANIZED SOLDER IS ALSO ACCEPTABLE. USE RUST-OLEUM COLD GALVANIZING COMPOUND SPRAY, OR SIMILAR. 12. ALL WELDING SHALL CONFORM TO REQUIREMENTS OF AWS STANDARDS. ALL WELDING SHALL BE SHIELDED METAL ARC WELDING. WELDS IN FINISH WORK SHALL BE FILLED OUT FLUSH, GROUND AND DISTRESSED. 13. ASTM A-36 FOR C, MC, ANGLES, AND PLATES. 14. ASTM A-53 GRADE B OR A-500 GRADE B OR A-501 GRADE B FOR STEEL PIPES. 15. ASTM A-123 STANDARD SPECIFICATION FOR ZINC (HOT-DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS 16. ASTM A-780 STANDARD PRACTICE FOR REPAIR OF DAMAGED AND UNCOATED AREAS OF HOT-DIP GALVANIZED COATINGS. SUPPLEMENTARY NOTES 1. THESE CONTRACT DOCUMENTS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE IMPROVEMENTS, WORKERS, AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, MEANS AND METHODS, BRACING, SHORING, FORMS, SCAFFOLDING, GUYING OR OTHER MEANS TO AVOID EXCESSIVE STRESSES AND TO HOLD ELEMENTS IN PLACE DURING CONSTRUCTION. OBSERVATION VISITS TO THE SITE BY THE ENGINEER SHALL NOT INCLUDE INSPECTION OF THE ABOVE ITEMS. 2. OPTIONS AND SUBSTITUTIONS (APPROVED BY OWNER/SKATEPARK DESIGNER/ARCHITECT) ARE FOR CONTRACTOR'S CONVENIENCE. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING ALL CHANGES AND ADDITIONAL COSTS NECESSARY AND SHALL COORDINATE ALL DETAILS WITH SKATEPARK DESIGNER THROUGH PRIME CONTRACTOR. 3. ANY ENGINEERING DESIGN PROVIDED BY CONTRACTOR OR OTHERS AND SUBMITTED FOR REVIEW SHALL BE WET SIGNED AND STAMPED BY AN INSURED REGISTERED STRUCTURAL OR CIVIL ENGINEER LICENSED IN THE STATE OF WHICH THE PROJECT IS LOCATED, IF REQUIRED BY CITY OR COUNTY. 4. UNLESS NOTED OTHERWISE, DETAILS ON CONSTRUCTION DRAWINGS ARE TYPICAL AS INDICATED BY CUTS, REFERENCES, OR TITLES. ALL DETAILS SHOWN SHALL BE IMPORTED INTO THE PROJECT AT ALL APPROPRIATE LOCATIONS, WHETHER SPECIFICALLY INDICATED OR NOT. TYPICAL DETAILS MAY OR MAY NOT BE REFERENCED ON THE DOCUMENTS, BUT SHALL APPLY AT ALL LOCATIONS, UNLESS NOTED OTHERWISE. WHERE NO DETAIL CUTS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK SHOWN ELSEWHERE ON THE PROJECT. FOR BIDDING PURPOSES, WHERE ANY SHOWN MEMBER OR STRUCTURAL ELEMENT IS NOT SIZED ON THE DOCUMENTS, THE LARGEST SIMILAR MEMBER USED IN THE PROJECT SHALL BE UTILIZED. 5. ALL DIMENSIONS AND ELEVATIONS SHOWN ON CONSTRUCTION DRAWINGS SHALL BE VERIFIED WITH ARCHITECTURAL DRAWINGS (IF REQUIRED BY THE PROJECT). RESOLVE ALL DISCREPANCIES WITH SKATEPARK DESIGNER AND PRIME CONTRACTOR PRIOR TO START OF CONSTRUCTION. DO NOT SCALE DRAWINGS. 6. CONTRACTOR SHALL ESTABLISH AND VERIFY IN FIELD ALL EXISTING CONDITIONS AFFECTING NEW CONSTRUCTION. CONTACT SKATEPARK DESIGNER AND PRIME CONTRACTOR IMMEDIATELY IF EXISTING CONDITIONS ARE NOT AS DEPICTED IN DRAWINGS. 7. *SKATE FEATURE DESIGN AND LAYOUT ARE THE RESPONSIBILITY OF THE SKATEPARK DESIGNER. PAVEMENT TOLERANCES 4. CONTRACTOR MUST ACHIEVE POSITIVE DRAINAGE FOR ALL SURFACES WITHIN THE SKATEPARK AREA WHENEVER POSSIBLE. REPAIRS AND PROTECTION 1. REMOVE AND REPLACE CONCRETE PAVEMENT THAT IS BROKEN, DAMAGED, OR DEFECTIVE, OR DOES NOT MEET REQUIREMENTS IN THIS SECTION. THE CONTRACTOR SHALL FIX ALL CRACKS AND DISPLACEMENTS LARGER THAN 1/8" UP TO THE PROJECT COMPLETION. 2. PROTECT CONCRETE FROM DAMAGE. EXCLUDE TRAFFIC FROM PAVEMENT FOR AT LEAST 14 DAYS AFTER PLACEMENT. WHEN CONSTRUCTION TRAFFIC IS PERMITTED, MAINTAIN PAVEMENT AS CLEAN AS POSSIBLE BY REMOVING SURFACE STAINS AND SPILLAGE OF MATERIALS AS THEY OCCUR. 3. MAINTAIN CONCRETE PAVEMENT OF FREE STAINS, DISCOLORATION, DIRT, AND OTHER FOREIGN MATERIAL.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1192 of 1214 SKATEPARK 46 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
41 63

Page 1222 of 1692 ends

1-800-227-2600 CA SPECIFICATIONS CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.SK2.1 SHOTCRETE SPECIFICATIONS PART 1- GENERAL 1.1 SUMMARY A. SPECIALTY CONSTRUCTION: A.A. DESCRIPTION: SHOTCRETE APPLICATION, CUTTING, SCULPTING AND FINISH WORK HAS BEEN DEEMED AS SPECIALTY CONSTRUCTION WORK WITHIN THE CONSTRUCTION DOCUMENTS. ALL WORK RELATED TO THE SPECIALTY CONSTRUCTION SHALL BE COORDINATED BY THE PROJECT ENGINEER, AND THE PRE-QUALIFIED SPECIALTY CONTRACTOR, PRIOR TO THE START OF CONSTRUCTION. 1.2 QUALITY ASSURANCE A. STANDARDS: COMPLY WITH THE REQUIREMENTS OF THE CURRENT EDITION OF THE FOLLOWING CODES AND STANDARDS, EXCEPT AS HEREIN MODIFIED: A.A. AMERICAN CONCRETE INSTITUTE (ACI): 506, CHAPTER 13, WET METHOD. CHAPTER 5, SHOTCRETE CREW A.B. ASTM: “AMERICAN SOCIETY FOR TESTING MATERIALS” 1.3 REFERENCE STANDARDS A. ACI 305- RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING. B. ACI 306- RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING. C. ASTM C33- CONCRETE AGGREGATES D. ASTM C94- READY-MIXED CONCRETE E. ASTM C143- TEST FOR SLUMP OF PORTLAND CEMENT CONCRETE F. ASTM C150- PORTLAND CEMENT G. ASTM C260- AIR-ENTRAINING ADMIXTURES FOR CONCRETE H. ASTM C494- CHEMICAL ADMIXTURES FOR CONCRETE I. ASTM C618- FLY ASH AND RAW OR CALCINED NATURAL POZZOLANS FOR USE IN PORTLAND CEMENT CONCRETE. 1.4 JOB CONDITIONS A. COORDINATION: A.A. COORDINATE SCHEDULES OF CONCRETE WORK TO ALLOW ADEQUATE TIME FOR INSTALLATION OF OTHER RELATED WORK. A.B. VERIFY THAT ANCHOR BOLTS AND OTHER EMBEDDED STEEL ITEMS TO BE CAST INTO CONCRETE ARE PROPERLY PLACED. A.C. COORDINATE EARTHWORK AND SOILS REPORT RECOMMENDATIONS WITH PLACEMENT REQUIREMENTS. A.D. COORDINATE WITH FORM-WORK AND FINISHES SECTIONS TO PROVIDE FINISH FLOORLEVELNESS AND FLATNESS AS SPECIFIED HEREIN. SLOPE TO DRAINS AT GRADES AND PERCENT SLOPE SHOWN IN THE CONSTRUCTION DRAWINGS. PART 2- SHOTCRETE WORK 2.1 SHOTCRETE MIX DESIGN A. PROVIDE MIX DESIGNS THAT WILL MEET THE MINIMUM REQUIREMENTS LISTED HEREIN: A.A. MINIMUM 28-DAY STRENGTH: 4000 PSI A.B. TYPE I/II/IL CEMENT A.C. SMALL AGGREGATE (1/2" MAX.) A.D. WATER/CEMENT RATIO OF .45 OR LESS A.E. AIR ENTRAINMENT NOT TO EXCEED 3% B. MIX DESIGNS FOR SHOTCRETE CONTAINING FLY ASH: THE AMOUNT OF FLY ASH USED SHALL NOT EXCEED 20% BY WEIGHT OF THE COMBINED WEIGHT OF FLY ASH PLUS CEMENT. 2.2 CONCRETE APPLICATION EQUIPMENT A. FOR WET MIX SHOTCRETE: A.A. MIXING EQUIPMENT: CAPABLE OF THOROUGHLY MIXING AGGREGATE, CEMENT AND WATER IN SUFFICIENT QUANTITY TO MAINTAIN CONTINUOUS PLACEMENT. A.B. AIR SUPPLY: CLEAN AIR ADEQUATE FOR MAINTAINING SUFFICIENT NOZZLE VELOCITY FOR PARTS OF WORK, AND FOR SIMULTANEOUS OPERATION OF BLOW PIPE FOR CLEANING AWAY REBOUND. A.C. DELIVERY EQUIPMENT: CAPABLE OF DISCHARGING AGGREGATE-CEMENT-WATER MIXTURE ACCURATELY, UNIFORMLY, AND CONTINUOUSLY THROUGH DELIVERY HOSE. PART 3- EXECUTION 3.1 INSPECTION A. EXAMINATION: EXAMINE CONCRETE FORMWORK AND VERIFY THAT IT IS TRUE TO LINE AND DIMENSION, ADEQUATELY BRACED AGAINST VIBRATION, AND CONSTRUCTED TO PERMIT ESCAPE OF AIR AND REBOUND BUT TO PREVENT LEAKAGE DURING SHOTCRETING. CORRECT DEFICIENCIES. B. NOTIFICATION: NOTIFY OTHER TRADES INVOLVED IN AMPLE TIME TO PERMIT THE PROPER INSTALLATION OF THEIR WORK. COOPERATE IN SETTING SUCH WORK. C. EXISTING SURFACES: EXAMINE EXISTING CONCRETE SURFACES FOR UNSOUND MATERIAL. CORRECT DEFICIENCIES. 3.2 PREPARATION FOR INSTALLATION OF CONCRETE A. FORMS: USE A FORM-COATING MATERIAL ON REMOVABLE FORMS TO PREVENT ABSORPTION OF MOISTURE AND TO PREVENT BOND WITH SHOTCRETE. 3.3 CONCRETE BATCHING AND MIXING A. PROPORTIONS: MIX PROPORTIONS SHALL BE CONTROLLED BY WEIGHT BATCHING. B. SCHEDULING: CONCRETE SHALL NOT EXCEED A TEMPERATURE OF 100 DEGREES FAHRENHEIT AT TIME OF PLACEMENT UNLESS PRE-APPROVED BY THE PROJECT ENGINEER. 3.4 CONCRETE PLACEMENT A. PLACEMENT: USE SUITABLE DELIVERY EQUIPMENT AND PROCEDURES THAT WILL RESULT IN SHOTCRETE IN PLACE MEETING THE REQUIREMENTS OF THIS SPECIFICATION. DETERMINE OPERATING PROCEDURES FOR PLACEMENT IN, EXTENDED DISTANCES, AND AROUND ANY OBSTRUCTIONS WHERE PLACEMENT VELOCITIES AND MIX CONSISTENCY MUST BE ADJUSTED. B. PLACEMENT TECHNIQUES: B.A. CONTROL THICKNESS, METHOD OF SUPPORT, AIR PRESSURE, AND/OR WATER CONTENT OF SHOTCRETE TO PRECLUDE SAGGING OR SLOUGHING OFF. DISCONTINUE SHOTCRETING OR PROVIDE SUITABLE MEANS TO SCREEN THE NOZZLE STREAM IF WIND OR AIR CURRENTS CAUSE SEPARATION OF THE NOZZLE STREAM DURING PLACEMENT. B.B. HOLD NOZZLE AS PERPENDICULAR TO SURFACE AS WORK WILL PERMIT, TO SECURE MAXIMUM COMPACTION WITH MINIMUM REBOUND. B.C. IN SHOTCRETING WALLS, BEGIN APPLICATION AT BOTTOM. ENSURE WORK DOES NOT SAG. B.D. LAYERING: B.D.A. BUILD UP LAYERS BY MAKING SEVERAL PASSES OF NOZZLE OVER WORK AREA. B.D.B. MAKE SURE SURFACE IS ADEQUATELY ROUGH TO WHICH, AFTER HARDENING, ADDITIONAL LAYERS OF SHOTCRETE ARE TO BE BONDED. B.D.C. DAMPEN SURFACE (ACHIEVE SATURATED SURFACE DRY (SSD) CONDITION) JUST PRIOR TO APPLICATION OF SUCCEEDING LAYERS. B.D.D. ALLOW EACH LAYER OF SHOTCRETE TO TAKE INITIAL SET BEFORE APPLYING SUCCEEDING LAYERS. B.D.E. USE RADIAL TEMPLATES TO INSURE EXACT RADII FROM FLAT BOTTOM OF BOWL/PIPE TO FACE OF COPING. TEMPLATE SHALL BE FABRICATED FROM STEEL OR 3/4” MINIMUM PLYWOOD. CHECK EVERY HORIZONTAL FOOT WHEN APPLYING SHOTCRETE FOR CONFORMANCE OF INTENDED WALL RADII. BRACE TEMPLATE AND PLACE LEVELS AT ARC TO TANGENT CONNECTIONS TO INSURE NO KINKS WILL BE FORMED. KINKS AT THE BOTTOM OF BOWLS WILL NOT BE ACCEPTABLE. SLUMPING OF THE SHOTCRETE CAUSING COPING SETBACK WILL NOT BE ACCEPTABLE. B.D.F. REMOVE ANY REBOUND OR ACCUMULATED LOOSE AGGREGATE FROM SURFACES TO BE COVERED PRIOR TO PLACING THE INITIAL OR ANY SUCCEEDING LAYERS OF SHOTCRETE. REBOUND SHALL NOT BE USED AS AGGREGATE. B.E. PLACEMENT AROUND REINFORCEMENT: B.E.A. HOLD THE NOZZLE AT SUCH DISTANCE AND ANGLE TO PLACE MATERIALS BEHIND REINFORCEMENT BEFORE ANY MATERIAL IS ALLOWED TO ACCUMULATE ON ITS FACE. B.F. ACCESS: ALLOW EASY ACCESS TO SHOTCRETE SURFACES FOR SCREEDING AND FINISHING, PERMITTING UNINTERRUPTED APPLICATION. 3.14 REMOVAL OF SURFACE DEFECTS IN CONCRETE A. GENERAL: REMOVE AND REPLACE SHOTCRETE WHICH LACKS UNIFORMITY, EXHIBITS SEGREGATION, HONEYCOMBING, OR LAMINATION, OR WHICH CONTAINS ANY DRY PATCHES, SLUGS, VOIDS OR POCKETS. REMOVE DEFECTIVE AREAS. 3.15 SHOTCRETE FINISH A. FINISH: ALL EXPOSED SHOTCRETE SURFACES ARE TO BE HARD STEEL TROWEL FINISH UNLESS OTHERWISE NOTED. TROWEL UNTIL ALL VISIBLE POURS ARE CLOSED. CEASE TROWEL BEFORE GLASS FORMS ON SURFACE. DO NOT BROOM FINISH AND DO NOT BURN SURFACE. B. GRINDING THE SURFACES WILL NOT BE AN ACCEPTABLE MEANS OF ACHIEVING THE INTENDED RADII/ANGLE. C. COLOR: ALL SHOTCRETE SURFACES ARE TO BE NATURAL GRAY COLOR UNLESS OTHERWISE NOTED. MINOR VARIATIONS IN APPEARANCE OF COLORED CONCRETE, WHICH ARE SIMILAR TO NATURAL VARIATIONS IN COLOR AND APPEARANCE OF UNCOLORED CONCRETE, ARE ACCEPTABLE. DO NOT BROOM FINISH AND DO NOT TROWEL BURN SURFACE. D. DURING THE CURING PERIOD, CONCRETE SHALL BE MAINTAINED AT A TEMPERATURE ABOVE 40 DEGREES FAHRENHEIT AND IN MOIST CONDITION. FOR INITIAL CURING, CONCRETE SHALL BE KEPT CONTINUOUSLY MOIST FOR 24 HOURS AFTER PLACEMENT IS COMPLETE. FINAL CURING SHALL CONTINUE FOR SEVEN DAYS AFTER PLACEMENT. COVER CONCRETE WITH POLYETHYLENE PLASTIC TO MAINTAIN TEMPERATURE IF NECESSARY. LAP SEAMS IN THE PLASTIC 6” AND WEIGH DOWN. E. THE CONTRACTOR SHALL FIX ALL CRACKS AND DISPLACEMENTS LARGER THAN 1/8” UP TO THE PROJECT COMPLETION. 3.16 CONCRETE PROTECTION AND CURING 1. NERAL: PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. COMPLY WITH ACI 306.1 FOR COLD-WEATHER PROTECTION AND FOLLOW RECOMMENDATIONS IN ACI 305R FORHOT-WEATHER PROTECTION DURING CURING. KEEP MOIST FOR NECESSARY AMOUNT OF TIME TO REACH CONCRETE STRENGTH AND INHIBIT MOISTURE LOSS AFTER PLACING. 2. EVAPORATION RETARDANT: WATERBORNE, MONOMOLECULAR FILM FORMING, MANUFACTURED FOR APPLICATION TO FRESH CONCRETE, SUCH AS EUCOBAR EVAPORATION RETARDANT BY THE EUCLID CHEMICAL COMPANY. APPLY EVAPORATION RETARDANT TO CONCRETE SURFACES IF HOT, DRY, OR WINDY CONDITIONS CAUSE MOISTURE LOSS BEFORE AND DURINGFINISHING OPERATIONS. APPLY TO EXPOSED SURFACE OF CONCRETE ACCORDING TO MANUFACTURERS WRITTEN INSTRUCTIONS AS NECESSARY. 3. BEGIN CURING AFTER FINISHING CONCRETE, BUT NOT BEFORE FREE WATER HAS DISAPPEARED FROM CONCRETE SURFACE. 4. CURING METHODS: CURE CONCRETE BY CURING COMPOUND, MOISTURE CURING, MOISTURE-RETAINING-COVER CURING, OR A COMBINATION OF THESE AS FOLLOWS: A. CURING COMPOUND: MEET REQUIREMENTS OF MANUFACTURER’S CURRENT PRINTED APPLICATION INSTRUCTIONS AND COVERAGE RATE CHART. FOR HORIZONTAL APPLICATIONS, IMMEDIATELY APPLY AFTER ALL SURFACE WATER HAS DISAPPEARED AND THE CONCRETE SURFACE IS HARD ENOUGH TO WALK ON. FOR VERTICAL APPLICATIONS, APPLY IMMEDIATELY AFTER REMOVING THE CONCRETE FORMS. APPLY IN A UNIFORM AND CONTINUOUS MANNER. AVOID OVER-APPLICATION OR PUDDLING OF CURING COMPOUND. PROTECT SURFACE FROM WATER, ADJACENT SHOTCRETE WORK, AND DEBRIS. B. MOISTURE CURING: KEEP SURFACES CONTINUOUSLY MOIST FOR NOT LESS THAN SEVEN DAYS WITH THE FOLLOWING MATERIALS: B.A. WATER. B.B. CONTINUOUS WATER-FOG SPRAY. B.C. ABSORPTIVE COVER, WATER SATURATED, AND KEPT CONTINUOUSLY WET. COVER CONCRETE SURFACES AND EDGES, OVERLAP SEAMS MIN. 6" BETWEEN ADJACENT ABSORPTIVE COVERS. C. MOISTURE-RETAINING-COVER CURING: C.A. COVER CONCRETE SURFACES WITH MOISTURE-RETAINING COVER FOR CURING CONCRETE, PLACED IN WIDEST PRACTICABLE WIDTH, WITH SIDES AND ENDS LAPPED AT LEAST 6 INCHES. 3.17 CURING MATERIALS 1. ABSORPTIVE COVER: AASHTO M 182, CLASS 2, BURLAP CLOTH MADE FROM JUTE OR KENAF, WEIGHING APPROXIMATELY 9OZ./SQ. YD. DRY. 2. MOISTURE-RETAINING COVER: ASTM C 171, POLYETHYLENE FILM OR WHITE BURLAP-POLYETHYLENE SHEET (BUR LENE). 3. WATER: POTABLE. 4. CURING COMPOUND: ASTM C-309, CLEAR, WATER-BASED, NO VOLATILE, NON-STAINING, MEMBRANE-FORMING, COMPATIBLE WITH SUBSEQUENT CONCRETE TREATMENTS. ACCEPTABLE PRODUCT: W.R. MEADOWS 1100-CLEAR, OR APPROVED EQUAL. 3.18 CONCRETE JOINTS A. CLEANING: THE ENTIRE JOINT SHALL BE THOROUGHLY CLEANED AND WETTED PRIOR TO THE APPLICATION OF ADDITIONAL SHOTCRETE. B. REINFORCEMENT: MAKE JOINTS PERPENDICULAR TO THE MAIN REINFORCEMENT. CONTINUE REINFORCEMENT ACROSS JOINTS. 3.19 CRACKING A. SAW CUT CONTROL JOINTS AND CONSTRUCTION JOINTS MAY BE SHOWN IN THE CONSTRUCTION DRAWINGS FOR DIAGRAMMATIC PURPOSES ONLY. THE CONTRACTOR MAY, WITH APPROVAL OF THE SKATEPARK DESIGNER, RECOMMEND AND DETAIL ADDITIONAL JOINTS TO HELP PREVENT CRACKING. B. THE CONTRACTOR SHALL FIX ALL CRACKS AND DISPLACEMENTS LARGER THAN 1/8” UP TO PROJECT COMPLETION.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1193 of 1214 SKATEPARK 47 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
42 63

Page 1223 of 1692 ends

CITY OF CUDAHY

PARK AND RECREATION DEPARTMENT
5220 SANTA ANA STREET
CUDAHY, CA 90201
323-773-5143

CITY OF CUDAHY

CUDAHY PARK RENOVATION PROJECT
13141 CROSSROADS PARKWAY NORTH, SUITE 405
INDUSTRY, CALIFORNIA 91746
(562) 908-6200

COMPREHENSIVE

INNOVATIVE

TRUSTED
Know what'sbelow.

Callbefore you dig.
®
PLAN NO. BID SET
PHASE 1
5220 SANTA ANA ST, CUDAHY, CA 90201
SK3.0

SKATEPARK

SITEPLAN

DEMOLITION

SYMBOL DESCRIPTION QTY
D-01 LIMIT OF DISTURBANCE 355 LF

DEMOLITION SCHEDULE
LOD
1-800-227-2600 CA N O R T H
0 10' 20'
Scale: 1" = 10'-0"
5'
1%
1%
1%
1%
1%
1%
1%
1%
1%

LOD LOD LOD
LOD
LOD
LOD
LOD
LOD

LOD LOD
LOD
LOD
LOD
LOD
LOD

LOD LOD LOD LOD LOD LOD LOD

LOD LOD LOD
LOD

LOD LOD
LOD
LOD
LOD

LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1194 of 1214 63

Page 1224 of 1692 ends

SYMBOL DESCRIPTION DETAIL 5" THK. CONCRETE FLATWORK QUARTERPIPE 7/SK9.1 QUARTERPIPE EXTENSION 8/SK9.1 CURVED QUARTERPIPE EXTENSION LA HIGH WALL 4/SK9.1 ROLL-IN 1/SK9.1 ROLLOVER 2/SK9.1 RAINBOW RAIL INSET SLAPPY MANUAL PAD 5/SK9.1 CANTILEVERED CURVED GRIND OUT LEDGE 3/SK9.1 CURVED SLAPPY CURB ROUND SLAPPY GRIND RAIL SP-01 SP-02 SP-03 SP-04 SP-05 SP-06 SP-07 SP-08 SP-09 SP-10 SP-11 SP-12 SECTION C, D E, P KMA, G, O B, H JN1, N2 IFL SYMBOL DESCRIPTION QTY DETAIL EXPANSION JOINT 106 LF 6/SK9.0 COLD JOINT OR KEY JOINT 448 LF SAWCUT JOINT 150 LF 7/SK9.0 TURNDOWN EDGE AT FINISH SURFACE 70 LF 3/SK9.0 TURNDOWN EDGE AT FINISH GRADE 96 LF 4/SK9.0 SC OR CJ - FIELD DETERMINED 134 LF H-01 H-02 H-03 H-04 H-05 H-06 EJ CJ-KJ SC-CJ JOINTING SCHEDULE INFORMATION SCHEDULE CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ

CJ-KJ CJ-KJ CJ-KJ CJ-KJ CJ-KJ CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ

CJ-KJ CJ-KJ CJ-KJ CJ-KJ CJ-KJ
CJ-KJ
CJ-KJ
CJ-KJ

CJ-KJ CJ-KJ CJ-KJ CJ-KJ

CJ-KJ CJ-KJ CJ-KJ

CJ-KJ CJ-KJ CJ-KJ CJ-KJ
CJ-KJ
CJ-KJ

CJ-KJ CJ-KJ CJ-KJ
CJ-KJ

CJ-KJ CJ-KJ CJ-KJ EJ EJ EJ EJ EJ EJ EJ EJ EJ
EJ

EJ CJ-KJ

EJ EJ EJ EJ SC-CJ
SC-CJ
SC-CJ
SC-CJ
SC-CJ
SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ SP-01 SP-01 SP-01 SP-01 SP-01 SP-01 SP-01 SP-02 SP-02 SP-02 SP-03 SP-04 SP-03 SP-06 SP-06 SP-06 SP-06 SP-06 SP-06 SP-06 SP-07 SP-07 SP-05 SP-09 SP-10SP-11 SP-12 SP-08 SC-CJ SC-CJ

SC-CJ SC-CJ

SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ SC-CJ CJ-KJ
CJ-KJ
CJ-KJ

CJ-KJ SC-CJ
EJ
EJ BLEND IN FIELD BLEND IN FIELD GENERAL NOTES: 1. SEE SHEET SK4.0 FOR COLOR PLAN. 2. THE SLAB CONFIGURATION, NOTES, LOCATION OF EXPANSION JOINTS, COLD JOINTS, SAW CUTS, DETAIL REFERENCES, AND APPLICABLE DETAILS HAVE BEEN INCLUDED FOR CLARITY. JOINTS AND DETAILS SHOWN ARE FOR THE SKATEPARK ONLY. REFER TO THE LANDSCAPE PLANS FOR SCOPES BEYOND THE SKATEPARK. 3. SUGGESTED ORDER OF CONSTRUCTION FOR CONCRETE ELEMENTS WITHIN THE SKATEPARK FOOTPRINT: A. SUBSURFACE DRAINAGE B. SUBGRADE PREP - GRADE, MOISTURE CONDITION, AND COMPACT SKATEPARK FOOTPRINT TO +/- .1' OF SPECIFIED SUBGRADE ELEVATIONS. C. FINE GRADING D. LEDGES AND MANUAL PADS E. BANKS AND TRANSITIONS F. GRIND RAIL FOOTING INSTALLATION G. FLOOR SLAB/FLATWORK 4. ALL EXPOSED CONCRETE AND SHOTCRETE SURFACES TO BE NATURAL GRAY IN COLOR WITH HARD STEEL TROWEL FINISH UNLESS OTHERWISE SPECIFIED. INFORMATION PLAN CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO. N O R T H 0Scale: 3/16" = 1'-0" 1' 5' 10' SK3.1 JOINTING NOTES: 1. JOINTING LAYOUT PLAN HAS BEEN DEVELOPED TO PROVIDE GUIDANCE TO THE CONTRACTOR FOR THE USE OF SAWCUTS, COLD + EXPANSION JOINTS. ACTUAL FIELD VARIANCES MAY BE NECESSARY AND WILL TAKE PRECEDENCE OVER THIS GUIDE. A CONTRACTOR SHALL CUT/JOINT CONCRETE AS NEEDED TO HELP MINIMIZE CRACKING AND ENHANCE SKATEABILITY. 2. ALIGN SAWCUTS WITH EXPANSION AND COLD JOINTS AND START FROM CORNERS WHERE POSSIBLE TO HELP MINIMIZE CRACKING. SAWCUTS SHOULD BE APPROXIMATELY 10'x12' AND/OR APPROXIMATELY 120 SQUARE FEET WITH ROUGHLY A 2:1 ASPECT RATIO BETWEEN SAWCUTS AND COLD OR EXPANSION JOINTS. 3. ALL HORIZONTAL SAWCUTS TO BE FILLED WITH SELF-LEVELING POLYURETHANE BASE ELASTOMERIC SEALANT AND TOOLED FLAT. EXPANSION JOINTS AND VERTICAL SAWCUTS TO BE FILLED WITH POLYURETHANE BASED NONSAGGING ELASTOMERIC SEALANT AND TOOLED FLAT. COLOR OF JOINT SEALANT SHOULD RESEMBLE NATURAL COLOR OF CONCRETE (ALUMINUM GRAY / LIMESTONE, OR SIMILAR) 4. ALL JOINTS TO BE FILLED WITH SEALANT, SEE TYPICAL DETAILS FOR MORE INFORMATION.

Cudahy Park Renovation Project, Project # PRE-001 Document Control 1195 of 1214 SKATEPARK 49 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
44 63

Page 1225 of 1692 ends

SYMBOL CODE DESCRIPTION QTY COLORED CAST-IN-PLACE CONCRETE TO BE 'PALOMINO' BY EA PIGMENTS OR APPROVED EQUAL 1,857 SF ALL OTHER CAST-IN-PLACE CONCRETE TO BE NATURAL GRAY C-01 C-02 CRlRU SCHEDULE C-02 C-02 C-02 C-02 C-02 C-02 C-02 C-01 C-01 C-01 C-01 C-01 C-01 C-01 COLOR NOTES: 1. CONCRETE COLOR AVAILABLE FROM EA PIGMENTS 1-888-222-7501, OR APPROVED EQUAL. 2. FINISH: ALL EXPOSED CONCRETE SURFACES ARE TO BE HARD STEEL TROWEL FINISH UNLESS OTHERWISE NOTED. TROWEL UNTIL ALL VISIBLE PORES ARE CLOSED. CEASE TROWELING BEFORE SURFACE BECOMES GLOSSY. DO NOT BROOM FINISH AND DO NOT TROWEL BURN SURFACE. 3. REFER TO STEEL PLAN ON SHEET SK7.0 FOR STEEL FINISH. COLOR PLAN CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO. N O R T H 0Scale: 3/16" = 1'-0" 1' 5' 10' SK4.0 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1196 of 1214 SKATEPARK PAVING COLOR PLAN 50 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
45 63

Page 1226 of 1692 ends

4'-4
1 8
"
9'-6
1 8
4'-6
"
1 8
"
5'-0"
5'-0"
9'-10
1 8
" 8'-9
1 4
" 9'-8
3 4
" 3'-0" 10'-0"
3'-0" 9'-8
3 4
" 10'-5
3 8
"
4'-0" 2'-10
7 8
"
20'-0"
4'-0" 4'-4
1 8
"
4'-1
1 8
" 4'-1
1 8
"
8'-2
1 4
"
6'-1"
6'-1"
1'-6"
1'-6"
9 1
2 " 12'-0"
9'-0" 18'-0"
8'-1
1 8
"
8'-1
1 8
" 3'-5
1 4 6'-1 " 7
8 " 2'-10
7 8
" 9'-7
3 8
"
10'-7
1 2
" 11'-5
1 2
" 7'-11
7 8
"
5'-8
1 8
"
3'-8
1 2
"
14'-7
7 8
" 4'-6
5 8
" 4'-6
5 8
" 14'-7
7 8
"
38'-6
3 8
"
27'-3
3 8
"
10'-1
3 4
"
10'-1
3 4
" 16'-1
1 8
R7'-5"
" R5'-1
1 2
"
R23'-2
3 4
"
R10'-9
1 2
"
R17'-0
7 8
"
R23'-2
3 4
" R5'-1
1 2
"
R11'-7"
R5'-9
1 2
"
R5'-9
1 2
"
R11'-7" R5'-9
1 2
"
R9'-8
1 4
"
R9'-8
1 4
" 7'-7
1 8 7'-7 " 5
8 "
20'-0" 12'-3
1 4
" 10'-3" 1'-10
1 2 5'-1 " 1
8 1'-10 " 1
2 " 13'-1
1 4
"
20'-0"
17'-10
1 2
"
12'-5"
5'-2
7 8
" 18'-10
3 4
"
18'-10
3 4
"
5'-2
7 8
"
5'-10"
R11'-3
3 8
" R11'-3
3 8
"
R11'-3
3 8
" R11'-3
3 8
"
R11'-3
3 8
" R5'-0"
R17'-5
1 4
" R5'-1
3 8
" 9'-11
1 8
" 5'-10
1 8
"
13'-11
1 2
"
9'-6
1 4
" 3'-9"
3'-8
3 8
"
17'-3
1 2
"
R27'-0"
R27'-0"
R25'-6"
R27'-0"
R27'-0"
R10'-0"
R17'-10
7 8
"
R17'-10
7 8
"
R10'-0"
45°
45°
R26'-2
1 2
"
R17'-7
7 8
" 2'-8
3 8
"
19'-6
7 8
" 7'-9
3 4
"
10'-0" 8'-9
7 8
"
16'-2" 2'-6
3 4
" 17'-4
3 4
" 7'-8
3 4
"
10'-11
1 2
" 2'-4
3 4
" 10'-2
3 8
" 14'-1
3 8
" **ALL COLD JOINTS AT THE BOTTOM OF ALL RADIUS TRANSITIONS & RADIUS BANKS SHALL BE LOCATED 8" MAX. FROM THE POINT OF TANGENCY. SEE TYPICAL DETAILS FOR CLARIFICATION. CONSTRUCTION NOTES: 1. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO ALL APPLICABLE GOVERNING CODES AND ORDINANCES. 2. ALL FORMS AND ALIGNMENTS OF PAVING, LAYOUT, AND SPECIAL PAVING AREAS SHALL BE REVIEWED AND APPROVED BY THE OWNER'S REPRESENTATIVE PRIOR TO POURING (GIVE A MINIMUM OF 24 HOURS NOTICE) 3. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL PUBLIC IMPROVEMENTS, INCLUDING UNDERGROUND UTILITIES PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL REPAIR AND/OR REPLACE IN-KIND ALL PUBLIC IMPROVEMENTS DAMAGED, BROKEN, OR REMOVED DURING CONSTRUCTION 4. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS (UNLESS OTHERWISE NOTED). 5. ALL REBAR CROSSINGS TO BE TIED. 6. ALL CONSTRUCTION TO BE PLUMB AND TRUE, UNLESS OTHERWISE NOTED OR INDICATED. 7. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE SKATE PARK DESIGNER, OWNER/BUILDER OR OWNER'S REPRESENTATIVE. 8. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION METHODS AND FOR SAFETY CONDITIONS AT THE WORK SITE. 9. ALL BRACING, TEMPORARY SUPPORTS, SHORING, ETC.. ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 10. OBSERVATION VISITS TO THE JOB SITE BY THE SKATE PARK DESIGNER OR OWNER, DO NOT INCLUDE INSPECTION OF CONSTRUCTION PROCEDURES. THE VISIT SHALL NOT BE CONSTRUED AS CONTINUOUS AND DETAILED INSPECTIONS. 11. CONDITIONS NOT SPECIFICALLY SHOWN SHALL BE CONSTRUCTED SIMILAR TO THE DETAILS FOR THE RESPECTIVE MATERIALS. 12. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED CONSTRUCTION PRODUCT. THESE DOCUMENTS, ALTHOUGH PREPARED WITH CARE AND DILIGENCE, MAY CONTAIN ERRORS, OMISSIONS, CONTRADICTIONS, ETC. THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS THOROUGHLY AND SHALL NOTIFY THE SKATE PARK DESIGNER IMMEDIATELY UPON ANY SUCH DISCOVERY OR DISCREPANCY. GOVERNING CODES SHALL THEN APPLY. 13. ALL SCALE DIMENSIONS ARE APPROXIMATE. WRITTEN DIMENSIONS AND DETAILS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR SHALL CHECK AND VERIFY ALL SITE DIMENSIONS PRIOR TO PROCEEDING WITH WORK AND CLARIFY WITH SKATE PARK DESIGNER, OWNER IF NECESSARY. 14. DESIGN, MATERIAL, EQUIPMENT AND PRODUCTS OTHER THAN THOSE DESCRIBED OR INDICATED ON DRAWINGS MAY BE CONSIDERED FOR USE. APPROVAL FOR SUBSTITUTIONS SHALL BE OBTAINED FROM THE SKATE PARK DESIGNER. 15. SHOP DRAWINGS SHALL BE SUBMITTED BY THE CONTRACTOR FOR THE CLARIFICATION OF DESIGN CONCEPT DETAILS & SUBSTITUTIONS. 16. DURING WORK AND THROUGH ITS COMPLETION, THE CONTRACTOR SHALL KEEP THE SITE CLEAN TO THE SATISFACTION OF THE OWNER. 17. FINAL MATERIAL, FINISHES AND COLOR SHALL BE APPROVED BY OWNER AND SKATE PARK DESIGNER PRIOR TO INSTALLATION. 18. CLEAN-UP SHALL TAKE PLACE ON A DAILY BASIS. 19. REFER TO SPECIFICATIONS FOR ANY ADDITIONAL INFORMATION. LAYOUT PLAN CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO. N O R T H 0Scale: 3/16" = 1'-0" 1' 5' 10' SK5.0
Cudahy Park Renovation Project, Project # PRE-001 Document Control 1197 of 1214 SKATEPARK 51 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
46 63

Page 1227 of 1692 ends

1%
1%
1% GB
1% GB
1%
1%
1%
1% +0' +0' +0' +0' -1.5' -1.5' +2.5' +2.5' +2.5' +3.5' +2' +2' +2' +3.5' +0' +1.5' 119.5' 119' 118' 117' 119.5' 119' 117' 118' 118.5' 118' 117' 119' 118' 117' GB GB GB GB +2' 117.51 FS
117.49 FS
117.65 FS
117.68 FS
117.69 FS
117.74 FS
116.72 TC
117.06 TC
116.22 TC 117.51 FS 117.31 FG
1% 117.46 FS 117.39 FS 117.33 FS 117.38 FS117.28 FS 117.37 FS117.32 FS117.36 FS 117.41 FS 117.32 FS 117.22 FS 117.14 FS 117.03 FS 116.83 FG 117.31 FS 117.20 FS 117.15 FS 116.95 FG 117.44 FS 117.55 FS 117.46 FS 117.36 FS 117.22 FS 117.02 FG 117.31 FS 117.51 FS 118.25 TR 117.25 FS 118.13 TR 117.13 FS 117.74 TL 117.07 FS 117.86 TL 117.18 FS 117.28 FS 117.08 FG 117.12 FS 116.92 FG 117.16 FS 16'-6
3 8
"@ 2.0%
29'-11
3 4
" @2.0%
39'-4
1 4
" @2.0% 119.66 FS 119.62 FS 119.85 TL 118.85 FS 118.65 FG 120.75 TL 119.75 FS 119.55 FG 120.90 TL 119.90 FS 120.90 TL 119.90 FS 119.80 FS 119.60 FG 119.80 FS 119.60 FG 120.40 TL 120.88 TL 119.88 FS 119.86FS 119.84 FS 119.64 FG 115.95 FS 115.95 FS 115.95 FS 115.95 FS 119.90 FS 115.85 FS 115.80 RIM 113.80 INV OUT 115.75 RIM 112.47 INV IN 111.97 INV OUT 117.00 FG 113.36 INV IN 115.80 RIM 114.30 INV OUT 116.34 FG 111.37 INV IN 115.90 FS 115.84 FS 115.86 FS 115.77 FS 117.33 FS 120.94 TL 119.44 FS 120.94 TL 119.44 FS 199.5' 117'118'119' 119.60 FS 119.58 FS 119.28 FG 119.58 FS 119.28 FG 117.32 FS 117.36 FS 117.28 FS 117.08 FG 117.32 FS 119.33 FS 115.85 FS 115.85 FS 117.07 FS 117.21 FS 117.45 FS 120.75 TL 119.78 FS 119.88 TL 118.88 FS 119.42 FS 119.22 FG 120.96 FS 118.89 FS 118.69 FG 117.49 FS 117.29 FG Landscape CODE DESCRIPTION QTY DETAIL AREA DRAIN 4 5/SK9.0 6" SDR 35 DRAIN LINE 117 LF L-01 L-02 L-03 DRAINAGE SCHEDULE 3 GRADING + DRAINAGE PLAN N O R T H
0Scale: 3/16" = 1'-0" 1' 5' 10' GRADING LEGEND: BS BOTTOM OF STEP FG FINISH GRADE FS FINISH SURFACE HP HIGH POINT INV INVERT ELEVATION (MAY CHANGE IN FIELD) PA PLANTING AREA TD TOP OF DRAIN TL TOP OF LEDGE TP TOP OF PAD TR TOP OF RAIL TS TOP OF STEP EXISTING ELEVATION (VERIFY IN FIELD) GRADING NOTES 1. ALL GRADING SHALL BE IN ACCORDANCE WITH THE LOCAL GRADING CODE AND ANY SPECIAL REQUIREMENTS OF THE GRADING PERMIT. 2. CONTRACTOR TO VERIFY GRADES AND NOTIFY ENGINEER PRIOR TO START OF GRADING WORK. 3. SLOPES SHALL BE NO STEEPER THAN 3' HORIZONTAL TO 1' VERTICAL (3:1) AND SHALL HAVE NOT LESS THAN 90% COMPACTION OUT TO THEIR FINISH SURFACES. 4. ALL PAVED AREAS SHALL SLOPE AS SHOWN ON PLANS WITH A 2% MAXIMUM FALL. PLANTED AREAS SHALL HAVE A MINIMUM 2% FALL. 5. FINISH GRADE SHALL HAVE A UNIFORM SURFACE, FREE OF LUMPS, BUMPS AND DEPRESSIONS AND ANY OBJECTS THAT MAY PREVENT A POSITIVE FLOW TO DRAIN. 6. ALL PROPOSED PAVING SURFACES SHALL MEET EXISTING PAVING SURFACES WITH SMOOTH AND CONTINUOUS TRANSITIONS AND FLUSH ALONG ENTIRE EDGE. 7. CONCRETE WALKS TO HAVE A MAXIMUM CROSS SLOPE OF 2% AND SHALL MEET ALL CITY AND COUNTY REQUIREMENTS. 8. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS, EXISTING DRAINAGE STRUCTURES, PARKING LOT IMPROVEMENTS, AND FINISH FLOOR ELEVATIONS. NOTIFY THE ENGINEER IMMEDIATELY UPON NOTING ANY DISCREPANCIES. 9. FINISH GRADE AT TURF AREAS SHALL BE ONE INCH BELOW FINISH SURFACE OF SIDEWALKS, CURBS OR PAVED AREAS. PLANTING AREA FINISH GRADE SHALL BE 2" BELOW SAME UNLESS OTHERWISE SPECIFIED. 10. ALL CONSTRUCTION AREAS SHALL BE FREE OF ROCK, DEBRIS, ETC. ALL EXISTING WEEDS SHALL BE REMOVED. 11. CONTRACTOR SHALL MEET EXISTING GRADE AT GRADING LIMITS WITH A SMOOTH AND CONTINUOUS TRANSITION. GB GB XXX.XX FS PROPOSED CONTOURS PROPOSED GRADE BREAK PROPOSED ELEVATIONS PROPOSED FLOW DIRECTION XX.XX 1. TYPICAL SLOPE DETAIL FOR INFORMATIONAL PURPOSES ONLY. ALL SLOPE GRADING AND DRAINAGE SHALL CONFORM TO APPROVED GRADING PLAN. CONCRETE PAVING FINISH GRADE, 2" CLR. @ NOTES SHRUB AREA, 1" CLR. @ TURF, TYP. SEE DRAINAGE PLAN 2'-0" TYP.

SEE DRAINAGE
PLAN 2% MIN. 1:1 1' 1' 2:1 1' 2' 3:1 1' 3' 4:1 1' 4' 5:1 1' 5' TYPICAL SLOPE FACTORS COMPACTED SUBGRADE TYPICAL SLOPE DETAIL 3/4" = 1'-0" P-PIP-CUD-25 1 CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.SK6.0 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1198 of 1214 SKATEPARK 52 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
47 63 L-01 L-01 L-01 L-02 L-02 L-03 L-03 4' DIA. X 10' SUMP DRAIN 2 9/SK9.1 L-01 L-02 L-03

Page 1228 of 1692 ends

STEEL SYMBOL DESCRIPTION QTY DETAIL FINISH 2-3/8" O.D. SCH. 40 STEEL COPING 122 LF 13/SK9.0 HOT DIPPED GALVANIZED STEEL EDGING 25 LF 9/SK9.0 HOT DIPPED GALVANIZED STEEL STRAP 30 LF 10/SK9.0 HOT DIPPED GALVANIZED CANTILEVERED STEEL EDGING 43 LF 11/SK9.0 HOT DIPPED GALVANIZED GRIND RAIL 20 LF HOT DIPPED GALVANIZED S-01 S-02 S-03 S-04 S-05 STEEL SCHEDULE 5'-0"
2'-0" 2'-0" 7'-1012" SEE SECTIONS 12'-0" SEE SECTIONS 10'-0" SEE SECTIONS 5'-23 8" SEE SECTIONS 20'-0"
20'-0"
4'-7" 19'-17 8" 22'-45 8" 15'-3 3 8" ACTUAL
27'-5 18" ACTUAL R11'-11 14" ACTUAL 1'-0" 18'-612" R27'-0" R25'-3" 45° 45° 10'-53 4" 9'-212" R20'-07 R18'-2 8" 7 8" R15'-8 14" ACTUAL R2'-0" 20'-0" R17'-107 8" COPING / RAIL JOINT WELDS G COPING G COPING UTILIZE HANDRAIL COUPLERS @ JOINT FOR WELD BACK UP CORNER SPLICE COPING END CAP 3/16" [4.76mm] GRIND SMOOTH END NOTES : 1. STEEL FINISH TO BE HOT DIPPED GALVANIZED AS INDICATED IN LEGEND FINISH. 2. FINISH MUST OCCUR AFTER ALL WELDING IS COMPLETE. 3. CAP ALL EXPOSED TUBE OR PIPE ENDS AND ROUND ALL SHARP EDGES. 4. ALL WELDS TO BE ALL AROUND. 5. GRIND ALL WELDS SMOOTH BEFORE FINISHING. 6. FABRICATE STEEL GRIND EDGES IN LONG SECTIONS THAT WILL WORK FOR SHIPPING AND REDUCE THE NUMBER OF WELDS IN THE FIELD. 7. CLEAN METAL EDGES AFTER PLACEMENT OF CONCRETE. 8. HOT DIPPED GALVANIZE REPAIR - FIELD WELDS SHALL BE GROUND SMOOTH AND TREATED WITH COLD GALVANIZING SPRAY. 10. SEE SECTION 05 50 00 - METAL FABRICATIONS OF SPECBOOK FOR SKATEPARKS FOR ALL STEEL SPECIFICATIONS.STEEL PLAN CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO. N O R T H 0Scale: 3/16" = 1'-0" 1' 5' 10' SK7.0 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1199 of 1214 SKATEPARK 53 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
48 63

Page 1229 of 1692 ends

6"
5"
5"
6" 6" R4'-0" R5'-6" 6" 7'-718" 2'-6" 8" SECTION A
5"
6" SECTION B
6"
5" R6'-6" R3'-0" R6'-6" 6" 10'-3"
1'-6"
5"
6" SECTION C
6"
5" R5'-6"
2'-6" 5'-25 8" 6" 8"
5"
6" SECTION D
6"
5" R6'-6" 6"
4'-0" 8" 6'-73 8"
6"
5"
5"
6" SECTION E 6"R6'-6" 8" 2'-0"
1'-0" 6'-1112" 8'-1112"
5'-0" SECTION F
5"
6" SECTION G
6"
5" R3'-0" R6'-6" 6" 8" 5'-912" 1'-6" SECTION H
5"
6" SECTION I FG 2'-0"
5" 7"
1'-0"
5"
6" SECTION J STEEL PLATE R6'-6" R4'-11" 23 8" 7'-53 4" 23 8" 6" 5" R6'-6" 9'-15 8"
1'-4" 8" 8" 4'-218" 7'-1012" 4'-218"
1'-115 8" 1'-03 8" 3'-0" 16'-25 8"
5"
6" SECTION K
6"
5" R6'-6" R6'-6" 5'-312" 23 8" 6'-45 8" VARIES - 2'-0"
@ PEAK11'-1012"
VARIES - 3'-6"
@ PEAK8" 6" 6" 8"
5"
6" SECTION L
6"
5" 45° 45° 1'-5" 1'-5" 1'-0" 10'-0" 1'-0" 12'-0"
1'-0" 23 8" 5'-812" 23 8" 5'-812" 23 8" 1'-4"
R4'-0" R6" 1'-0"
5"
6" 4'-47 8 2'-10 " 7 8" 8"
2'-0" FG 8'-33 4" 12 SK9.0 12 SK9.0 12 SK9.0 12 SK9.0 12 SK9.0 57 8" 214" 5" 214" 912" 21° 5"
6"FG 614" AC D B F E D I B G J G K L N1 M OHH N2 BLEND IN FIELD BLEND IN FIELD 0 1' 2' 4' Scale: 3/8" = 1'-0" N O R T H SECTIONS CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.SK8.0 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1200 of 1214 SKATEPARK 54 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
49 63

Page 1230 of 1692 ends

5"
6" SECTION M FG R3'-0" 6" 8" 4'-83 4" 1'-0" 5'-83 4"
2'-6"
5"
6" SECTION N1 FG 40° 1'-0" 2'-218" 5'-23 8" 414"
8" 1'-10"
2'-6" 8'-83 4"
6" 62° 40°
5"
6" SECTION N2
6"
5" 10'-0"
8"
6"
8" SECTION O
5"
6" FG R4'-0" 6" 2'-107 8" 95 8" 4'-714"
3'-53 4"
1'-53 4" 8'-33 4" 1'-6" 1'-0" 4'-714" 3'-6" 8" 8'-33 4" 2'-812" 6" R4'-0" 6" 2" x 9-1/8" FOLDED STEEL 2" x 8" STEEL EDGING 2" x 8" STEEL EDGING 2" x 2" STEEL STRAP 2" x 2" STEEL STRAP AC D B F E D I B G J G K L N1 M OHH N2 BLEND IN FIELD BLEND IN FIELD 0 1' 2' 4' Scale: 3/8" = 1'-0" N O R T H SECTIONS CITY OF CUDAHY PARK AND RECREATION DEPARTMENT 5220 SANTA ANA STREET CUDAHY, CA. 90201 323-773-5143 CITY OF CUDAHY CUDAHY PARK RENOVATION PROJECT 13141 CROSSROADS PARKWAY NORTH, SUITE 405 INDUSTRY, CALIFORNIA 91746 (562) 908-6200 COMPREHENSIVE INNOVATIVE TRUSTED Know what's below. Call before you dig.  ® PLAN NO.SK8.1 Cudahy Park Renovation Project, Project # PRE-001 Document Control 1201 of 1214 SKATEPARK 55 BID SET CUDAHY PARK RENOVATION PROJECT CUDAHY PARK RENOVATION PROJECTPHASE 1 5220 SANTA ANA ST, CUDAHY, CA 90201
50 63

Page 1231 of 1692 ends
← All documents from this meeting