16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 84 of 140 One (1) individual "Innovative Control" lift up drain valve shall be furnished for each 1-1/2" or larger discharge port and each 2-1/2" gated auxiliary suction.
Drain/bleeder valves shall be located at the bottom of the side pump module panels. All drains and bleeders shall discharge below the running boards.
PO00004840 - SYNFLEX SUCTION, DISCHARGE, PRESSURE AND CONTROL LINES Small lines within the pump enclosure shall be constructed from Synflex hose.
Uses include but are not limited to such lines as priming control, gauge lines, drain lines, air control valves, pump shift, supplemental cooling, foam flush, and air bleeder valves.
PO00010965 - SUCTION INLETS - 6” INLETS
Two (2) 6" N.S.T. suction inlets shall be provided, one on the driver side and one on the officer side pump panel.
A removable strainer shall be installed on each inlet.
PO00024018 - SHORT NECK MAIN PUMP SUCTION INLETS
The main pump suction inlets shall be furnished with a short suction end, terminating with only the suction threads protruding through the side panel to minimize the distance an exterior appliance protrudes beyond the pump panel.
PO00012076 - BEHIND PANEL MOUNT
All side gated inlet valves shall be recess mounted behind the side pump panels or body panels. There will be no exceptions.
PO00023976 - 6" NST INTAKE CAP - DRIVER SIDE
A 6" NST chrome plated long handle pressure vented cap shall be installed on driver side intake.
PO00023980 - 6" NST INTAKE CAP - OFFICER SIDE
A 6" NST chrome plated long handle pressure vented cap shall be installed on officer side intake.
PO00011334 - 2-1/2" DRIVER SIDE AUX SECONDARY SUCTION INLET REAR OF MAIN One (1) 2-1/2" auxiliary suction shall be provided at the driver side pump panel, to the rear of the main inlet (if space and other components allow).
The 2-1/2" auxiliary suction shall terminate with a removable strainer, chrome plated 2-1/2" NST female swivel with a chrome plated plug and retaining chain.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 85 of 140 PO00004965 - 2-1/2" AKRON #8800 S.S. BALL VALVE, DRIVER SIDE REAR AUX SUCTION An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side rear auxiliary suction.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00004978 - SWING CONTROL @ VALVE, DRIVER SIDE REAR AUX SUCTION A 1/4 turn swing control handle shall be provided on the driver side rear auxiliary suction valve.
PO00011323 - TANK TO PUMP
One (1) 4" tank to pump line shall be piped through the front bulkhead of the tank with a 90-degree elbow down into the tank sump.
This line shall be plumbed directly into the rear of the pump suction manifold for maximum efficiency.
A check valve shall be provided to prevent accidental pressurization of the water tank through the pump connection.
Connection from the valve to the tank shall be made by using a non-collapsible flexible rubber hose.
PO00004999 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE, TANK TO PUMP An Akron Brass 3" Generation II Swing-Out Valve shall be provided between the pump suction manifold and the water tank.
The valve shall have an all-brass body with flow optimizing, stainless-steel ball and dual polymer seats.
PO00010956 - 3" PUSH/PULL CONTROL FOR TANK TO PUMP
A push/pull control handle shall be located on the operator's panel with function plate.
PO00022945 - PUMP AND ROLL PLUMBED TO MAINT TANK
The auxiliary pump-and-roll pump shall be plumbed into the main tank-to-pump line downstream of the tankto-pump valve.
PO00011326 - PUSH-PULL CONTROL NORMALLY OPEN - IN / OPEN, OUT / CLOSE The tank-to-pump push pull handle shall be oriented so that it is "IN" to "OPEN" and "OUT" to "CLOSE".
This shall allow it to be normally open for pump-and-roll operations.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 86 of 140 PO00010962 - TANK FILL LINE 2" FROM PUMP - SIDE MOUNT
One (1) 2" gated full flow pump to tank refill line controlled at the pump panel shall be provided. A deflector shield inside the tank shall be furnished. Tank fill plumbing shall utilize 2" high pressure hose for tank connection to accommodate flexing between components. There will be no exceptions.
PO00005031 - 2" AKRON #8800 SERIES - S.S. BALL TANK FILL, SIDE MOUN An Akron Brass 2" Generation II Swing-Out Valve shall be provided between the pump discharge manifold and the water tank.
The valve shall have an all-brass body with flow optimizing, stainless-steel ball, and dual polymer seats.
PO00009815 - PUSH/PULL CONTROL FOR TANK FILL
A push/pull control handle shall be located on the operator's panel with function plate.
PO00012083 - DRIVER SIDE MAIN DISCHARGE #1
A discharge shall be provided and located at the driver's side pump panel.
The driver's side discharges # 1 shall terminate with NST threads, through the left panel above the main pump intake.
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.
PO00009226 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, DRIVER SIDE #1 An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side #1 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00005054 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP DRIVER SIDE DISCHARGE #1 A 2-1/2" NSTF X 1-1/2" NSTM reducer with cap shall be provided on the driver's side # 1 discharge.
PO00005039 - DS #1 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight 2 1/2" NST adapter that shall be equipped with a 2 1/2" NST, 30-degree, chrome plated elbow.
PO00005085 - SWING 1/4 TURN CONTROL FOR DRIVER SIDE DISCHARGE #1 -SIDE MOUNT The driver's side # 1 discharge valve shall be controlled by a 1/4 turn swing control handle located on the operator's panel.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 87 of 140 PO00005131 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - DRIVER SIDE DISCHARGE #1 The driver's side # 1 discharge shall be equipped with a Class One, 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright, metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00005134 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.
PO00012084 - DRIVER SIDE MAIN DISCHARGE #2
A discharge shall be provided and located at the driver's side pump panel.
The driver's side discharges # 2 shall terminate with NST threads, through the left panel above the main pump intake.
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.
PO00009304 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, DRIVER SIDE #2 An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side #2 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00005145 - DS #2 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight 2 1/2" NST adapter that shall be equipped with a 2 1/2" NST, 30-degree, chrome plated elbow.
PO00005160 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP DRIVER SIDE DISCHARGE #2 A 2-1/2" NSTF X 1-1/2" NSTM reducer with cap shall be provided on the driver's side # 2 discharge.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 88 of 140 PO00005188 - SWING 1/4 TURN CONTROL FOR DRIVER SIDE DISCHARGE #2 -SIDE MOUNT The driver's side # 2 discharge valve shall be controlled by a 1/4 turn swing control handle located on the operator's panel.
PO00005233 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - DRIVER SIDE DISCHARGE #2 The driver's side # 2 discharge shall be equipped with a Class One, 2 1/2" pressure gauge, which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00005236 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.
PO00012086 - OFFICER SIDE MAIN DISCHARGE #1
A discharge shall be provided and located at the officer's side pump panel.
The officer's side discharges #1 shall terminate with NST threads, through the officer's side panel above the main pump intake.
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.
PO00005281 - 4" AKRON #8840 VALVE, OFFICER SIDE #1, SIDE MOUNT An Akron Brass, 4" Heavy Duty, Swing-Out Valve shall be provided for the officer's side #1 discharge.
The valve shall have an all-brass body with flow optimizing, flat ball, and dual polymer seats PO00005298 - OS #1 DISCHARGE - 4" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight, 4" NST adapter that shall be equipped with a 4" NST, 30-degree, chrome plated elbow.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 89 of 140 ***SPECIAL: SP00020023 - 4" NSTF X 2.5" NSTM REDUCER WITH CAP OFFICER SIDE DISCHARGE # 1 A 4" NSTF X 2.5" NSTM reducer with cap shall be provided on the officer's side # 1 discharge.
PO00005362 - AKRON HANDWHEEL GEAR VALVE CONTROL, OFFICER SIDE DISCHARGE #1 The officer's side # 1 discharge valve shall be gated with an Akron Hand wheel controlled, inline valve.
The valve shall be controlled at the pump operator's panel with a chrome plated hand wheel and mechanical valve position indicator.
PO00005380 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - OFFICER SIDE DISCHARGE #1 The officer's side, # 1 discharge shall be equipped with a Class One, 2 1/2" pressure gauge which shall contain a vibration dampened, internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00005383 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.
PO00012087 - OFFICER SIDE MAIN DISCHARGE #2
A discharge shall be provided and located at the officer's side pump panel.
The officer's side discharges #2 shall terminate with NST threads, through the officer's side panel above the main pump intake.
The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.
PO00005393 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, OFFICER SIDE #2, SIDE MOUNT An Akron Brass, 2 1/2" Generation II, Swing-Out Valve shall be provided for the officer's side #2 discharge.
The valve shall have an all-brass body with flow optimizing, stainless-steel ball, and dual polymer seats.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 90 of 140 PO00005403 - OS #2 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight, 2 1/2" NST, adapter that shall be equipped with a 2 1/2" NST, 30-degree, chrome plated elbow.
PO00005418 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER W/CAP OFFICER SIDE DISCHARGE #2 A 2-1/2" NSTF X 1-1/2" NSTM reducer w/ cap shall be provided on the officer's side #2 discharge.
PO00005447 - SWING 1/4 TURN CONTROL FOR OFFICER SIDE DISCHARGE #2 -SIDE MOUNT The officer's side, #2 discharge valve shall be controlled by a 1/4 turn swing control handle located on the operator's panel.
PO00005492 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - OFFICER SIDE DISCHARGE #2 The officer's side, #2 discharge shall be equipped with a Class One, 2 1/2" pressure gauge which shall contain a vibration dampened, internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright, metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00005495 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.
PO00012097 - OFFICER SIDE REAR DISCHARGE 2-1/2"
A 2 1/2" NST rear discharge shall be provided at the rear of the vehicle, plumbed from the pump.
PO00005741 - OS REAR DISCHARGE TERMINATE @ OFFICER SIDE REAR BODY PANEL The rear discharge shall terminate on the rear body panel, on the officer side of the body.
PO00005745 - 2-1/2" NST MALE THREADS ON OFFICER SIDE REAR DISCHARGE The discharge shall be equipped with a 30-degree droop terminating in 2-1/2" NSTM threads.
The officer side rear discharge pipe shall be furnished with 2-1/2" NSTM threads.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 91 of 140 PO00005752 - OS REAR DISCHARGE, PLUMBING, 2-1/2" STAINLESS-STEEL PIPING The officer side rear discharge shall be plumbed utilizing 2 1/2" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
PO00005761 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE REAR DISCHARGE An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the officer's side rear discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00005774 - PUSH/PULL CONTROL FOR OFFICER SIDE REAR DISCHARGE The officer side rear discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00005819 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP - OFFICER SIDE REAR DISCHARGE A 2-1/2" NSTF X 1-1/2" NSTM reducer(s) with cap shall be provided on the officers’ side rear discharge.
PO00005850 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - OFFICER SIDE REAR DISCHARGE The officer side rear discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00005853 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.
PO00012103 - DRIVER SIDE HOSE BED DISCHARGE 2-1/2"
A 2 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front of the hose bed.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 92 of 140 PO00005863 - DS HOSE BED DISCHARGE TERMINATE @ FLOOR LEVEL FRONT The rear hose bed discharge shall terminate just above the hosebed floor, in the driver side front of the hose bed.
PO00005867 - 2-1/2" NST MALE THREADS ON DRIVER SIDE HOSE BED DISCHARGE The driver side hose bed discharge pipe shall be equipped with a chrome 2 1/2" NSTM thread adapter.
PO00005871 - DS HOSE BED DISCHARGE, PLUMBING, 2-1/2" STAINLESS-STEEL PIPING The driver side hose bed discharge shall be plumbed utilizing 2 1/2" schedule 10 stainless-steel piping, 45- degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
PO00005876 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE DRIVER SIDE HOSE BED DISCHARGE An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side hose bed rear discharge. The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00005886 - PUSH/PULL CONTROL FOR DRIVER SIDE HOSE BED DISCHARGE The driver side hose bed discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00005935 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - DRIVER SIDE HOSE BED DISCHARGE The driver side hose bed discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00005938 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 93 of 140 PO00012105 - OFFICER SIDE HOSE BED DISCHARGE 1-1/2"
A 1 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front of the hose bed.
PO00005948 - OS HOSE BED DISCHARGE TERMINATE @ FLOOR LEVEL FRONT The rear hose bed discharge shall terminate just above the hose bed floor, in the officer's side front of the hose bed.
PO00005950 - 1-1/2" NST MALE THREADS ON OFFICER SIDE HOSE BED DISCHARGE The officer's side hose bed discharge pipe shall be equipped with a chrome 1 1/2" NSTM thread adapter.
PO00005954 - OS HOSE BED DISCHARGE, PLUMBING, 2" STAINLESS-STEEL PIPING The officer's side hose bed discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
PO00005960 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE HOSE BED DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the officer's side hose bed discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00005971 - PUSH/PULL CONTROL FOR OFFICER SIDE HOSE BED DISCHARGE The officer's side hose bed discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006014 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - OFFICER SIDE HOSE BED The officer's side hose bed discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 94 of 140 The gauge face shall be white with black numerals.
PO00006017 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.
PO00012151 - OFFICER SIDE HOSE BED DISCHARGE #2 - 1-1/2" A 1 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front of the hose bed.
PO00010354 - OS HOSE BED DISCHARGE #2 TERMINATE @ FLOOR LEVEL FRONT The rear hose bed discharge shall terminate just above the hose bed floor, in the officer's side front of the hose bed.
PO00010404 - 1-1/2" NST MALE THREADS ON OFFICER SIDE HOSE BED DISCHARGE #2 The officer's side hose bed discharge pipe shall be equipped with a chrome 1 1/2" NSTM thread adapter.
PO00010387 - OFFICER SIDE HOSE BED DISCHARGE #2, PLUMBING, 2" STAINLESS-STEEL PIPING The officer's side hose bed discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
PO00010393 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE HOSE BED DISCHARGE #2 An Akron Brass 2" Generation II Swing-Out™ Valve shall be provided for the officer's side hose bed discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00010356 - PUSH/PULL CONTROL FOR OFFICER SIDE HOSE BED DISCHARGE #2 The officer's side hose bed discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00010353 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP - OFFICER SIDE HOSE BED DISCHARGE #2 A 2-1/2" NSTF X 1-1/2" NSTM reducer with cap shall be provided on the officers’ side hose bed discharge.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 95 of 140 PO00010335 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - OFFICER SIDE HOSE BED DISCHARGE #2 The officer's side hose bed discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00010338 - RED ILLUMINATED GAUGE - CLASS ONE - OFFICER SIDE HOSE BED DISCHARGE #2 The color of the illuminated Class One gauge shall be Red.
PO00012108 - DECK GUN DISCHARGE
A deck gun discharge shall be plumbed from the pump to an area on top of the vehicle.
The deck gun piping shall be firmly supported and braced.
PO00006023 - DECK GUN DISCHARGE TERMINATE @ CENTER OF DUNNAGE The deck gun discharge shall be located in the center of the dunnage area above the pump module.
A pedestal type, 1/4" steel plate support assembly shall be provided to stabilize deck gun plumbing below deck gun mount flange.
PO00026331 - DECK GUN DISCHARGE TERMINATION TO MATCH DECK GUN The deck gun discharge pipe shall terminate with a connection matching the specified deck gun model and accessories.
PO00006036 - DECK GUN DISCHARGE - OVA HEIGHT NOT EXCEED CRITICAL OVERALL HEIGHT RESTRICTION Deck gun height will be limited to the critical overall apparatus height listed in the spec. To avoid excessive travel heights the monitor will be positioned as low a practical while still allowing functionality of water stream.
PO00006039 - DECK GUN DISCHARGE, PLUMBING, 3" STAINLESS-STEEL PIPING The deck gun discharge shall be plumbed utilizing 3" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the deck gun location.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 96 of 140 A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
PO00006045 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE DECK GUN DISCHARGE An Akron Brass 3" Generation II Swing-Out Valve shall be provided for the deck gun discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00006058 - PUSH/PULL CONTROL FOR DECK GUN DISCHARGE
The deck gun discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006101 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - DECK GUN DISCHARGE The deck gun discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00006104 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red. ***SPECIAL: SP00037855 - AKRON MODEL #3433 "HI-RISER" MANUAL DECK GUN KIT An Akron model # 3433 "HI-RISER" deck gun shall be supplied and mounted on the deck gun discharge of the unit to provide the maximum travel clearance. The monitor shall be equipped with a portable ground base with one 4" NSTF swivel inlet. The monitor shall come equipped with a set of stack tips and an Akron model # 1755 Turbomaster" 1250 GPM nozzle. The monitor shall also include the following: Pressure gauge on the monitor, carry handle for portable usage, grease fittings for maintenance, safety chains, hardened steel ground spikes and Pyrolite construction.
PO00012110 - #1 FRONT DISCHARGE 1-1/2"
A 1 1/2" front #1 discharge shall be plumbed to the front bumper of the vehicle.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 97 of 140 PO00006327 - 1-1/2" NST CHICKSAN SWIVEL #1 DISCHARGE- HOSE WELL ON FRONT BUMPER The front #1 discharge shall terminate with a brass 1 1/2" NST chicksan swivel adapter in the hose well on the front bumper.
PO00006349 - #1 FRONT DISCHARGE, PLUMBING, 2" STAINLESS-STEEL PIPING The front #1 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping, flexible hosing, 45- degree elbows, and a limited number of 90 degree sweep elbows in an assembly from the pump to the front of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
Automatic discharge drains shall be provided at all low points in the plumbing.
PO00006360 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE FRONT#1 DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the front #1 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00006377 - PUSH/PULL CONTROL FOR FRONT #1 DISCHARGE
The front #1 discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006427 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - FRONT #1 DISCHARGE The front #1 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00006430 - RED ILLUMINATED GAUGE - CLASS ONE - FRONT #1 DISCHARGE The color of the illuminated Class One gauge shall be Red, on the front #1 discharge.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 98 of 140 PO00012113 - #2 FRONT DISCHARGE 1-1/2"
A 1 1/2" front discharge shall be plumbed to the front bumper of the vehicle.
PO00006443 - 1-1/2" NST CHICKSAN SWIVEL #2 DISCHARGE- HOSE WELL ON FRONT BUMPER The front discharge #2 shall terminate with a chrome 1 1/2" NST chicksan swivel adapter in a location on the front bumper as directed by engineering.
PO00006468 - #2 FRONT DISCHARGE, PLUMBING, 2" STAINLESS-STEEL PIPING The front discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45- degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the front of the vehicle.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.
Automatic discharge drains shall be provided at all low points in the plumbing.
PO00006479 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE FRONT #2 DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the front #2 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00006496 - PUSH/PULL CONTROL FOR FRONT #2 DISCHARGE
The front #2 discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006546 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - FRONT #2 DISCHARGE The front #2 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 99 of 140 PO00006549 - RED ILLUMINATED GAUGE - CLASS ONE- FRONT #2 DISCHARGE The color of the illuminated Class One gauge shall be Red, on the front #2 discharge.
PO00000011 - CROSSLAY #1, 1-1/2" - PUMPER
A crosslay hose bed shall be provided and plumbed from the pump in a transverse design, located above the pump enclosure for quick attack deployment. The crosslay hose bed flooring shall be designed to be removable and constructed from brushed finish, perforated aluminum material.
PO00000014 - CROSSLAY #1 CAPACITY - 200 FEET OF 1-3/4" HOSE Crosslay #1 shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA -1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.
PO00000022 - CROSSLAY #1 - DOUBLE STACK HOSE DESIGN
Crosslay #1 hose bed shall be designed to accommodate the fire hose in a double stack configuration.
PO00006565 - 1-1/2" NST CHICKSAN SWIVEL - CROSSLAY #1
The crosslay discharge shall terminate below the hosebed floor with a 1 1/2" NSTM chicksan swivel adapter.
The crosslay hose bed floor shall be slotted to allow the swivel to extend up through the floor, allowing the pre-connected hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.
PO00006572 - CROSSLAY #1, PLUMBING, 2" STAINLESS-STEEL PIPING The crosslay #1 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to crosslay hose bed.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly, if necessary, to allow for flex and serviceability.
PO00006578 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE CROSSLAY #1, DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the crosslay #1 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00006592 - PUSH/PULL CONTROL CROSSLAY #1
The crosslay #1 discharge valve shall be controlled by a push/pull handle located on the operator's panel.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 100 of 140 PO00006635 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - CROSSLAY #1 The crosslay #1 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00006638 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.
PO00007712 - CROSSLAY #2 1-1/2"
A crosslay hose bed shall be provided and plumbed from the pump in a transverse design, located above the pump enclosure for quick attack deployment.
The crosslay hose bed flooring shall be designed to be removable, constructed from brushed finish, perforated aluminum material.
PO00000024 - CROSSLAY #2 CAPACITY - 200 FEET OF 1-3/4" HOSE Crosslay #2 shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA -1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.
PO00000032 - CROSSLAY #2 - DOUBLE STACK HOSE DESIGN
Crosslay #2 hose bed shall be designed to accommodate the fire hose in a double stack configuration.
PO00024219 - 1-1/2" NST CHICKSAN SWIVEL - CROSSLAY #2
The crosslay discharge shall terminate below the hose bed floor with a 1 1/2" NSTM chicksan swivel adapter.
The crosslay hose bed floor shall be slotted to allow the swivel to extend up through the floor, allowing the pre-connected hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 101 of 140 PO00006661 - CROSSLAY #2, PLUMBING, 2" STAINLESS-STEEL PIPING The crosslay #2 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to crosslay hose bed.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly, if necessary, to allow for flex and serviceability.
PO00006667 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE CROSSLAY #2, An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the crosslay #2 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.
PO00006681 - PUSH/PULL CONTROL CROSSLAY #2
The crosslay #2 discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006722 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - CROSSLAY #2 The crosslay #2 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00006725 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.
PO00007715 - CROSSLAY #3 1-3/4"
A crosslay hose bed shall be provided and plumbed from the pump in a transverse design, located above the pump enclosure for quick attack deployment.
The crosslay hose bed flooring shall be designed to be removable, constructed from brushed finish, perforated aluminum material.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 102 of 140 PO00000034 - CROSSLAY #3 CAPACITY - 200 FEET OF 1-3/4" HOSE Crosslay #3 shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA -1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.
PO00000042 - CROSSLAY #3 - DOUBLE STACK HOSE DESIGN
Crosslay #3 hose bed shall be designed to accommodate the fire hose in a double stack configuration.
PO00006741 - 1-1/2" NST CHICKSAN SWIVEL - CROSSLAY #3
The crosslay discharge shall terminate below the hosebed floor with a 1 1/2" NSTM chicksan swivel adapter.
The crosslay hose bed floor shall be slotted to allow the swivel to extend up through the floor, allowing the pre-connected hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.
PO00006744 - CROSSLAY #3, PLUMBING, 2" STAINLESS-STEEL PIPING The crosslay #3 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to crosslay hose bed.
A minimum of one (1) grooved pipe coupling shall be furnished in this assembly, if necessary, to allow for flex and serviceability.
PO00006750 - PUSH/PULL CONTROL CROSSLAY #3
The crosslay #3 discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00006793 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - CROSSLAY #3 The crosslay #3 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 103 of 140 PO00006796 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.
PO00009196 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE CROSSLAY #3, An Akron Brass 2" Generation II Swing-Out™ Valve shall be provided for the crosslay #3 discharge.
The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats. ***SPECIAL: SP00008482 - VINYL END FLAPS FOR ALUMINUM TREADPLATE CROSSLAY COVER Two (2) piece crosslay end flaps will be provided to accommodate the two individual crosslay doors. The flaps will attach at the bottom with postman straps and ¼ turn fasteners on the covers.
PO00011385 - END FLAP COVER BLACK IN COLOR
The crosslay end flap shall be black in color.
***SPECIAL: SP00017079 - PUMP ENCLOSURE HOSEBED HOSE RETENTION Provide two (2) 3/16” aluminum tread plate crosslay covers. One (1) will be forward hinged that will cover the front two crosslays and the second will be rear hinged that will cover the other remaining crosslays. Each lid will have a “D” handles on top to allow for easier opening. The forward lid shall have a rubber grommet centered in the middle of the cover to prevent the cover from contacting the scene light mounted on the rear cab wall.
***SPECIAL: SP00037845 - 6.5" FRONT CROSSLAY BULKHEAD
The crosslay bulkhead will be 6.5" wide to allow the front crosslay to clear the back of cab telescoping lights and allow space for backboard storage.
***SPECIAL: SP00037878 - BACK BOARD STORAGE SLOT WITHIN CROSSLAY BULKHEAD A storage area within the front crosslay bulkhead shall be designed to accommodate one (1) backboard, the storage slot shall be sized 18" tall x 2" wide x 74" long to accommodate a standard size backboard. Each side shall be accessed by a forward hinged door with thumb latches. Door material to match the pump panel material.
The storage area shall have nylon material on the bottom surface to protect the backboard.
PO00012125 - BOOSTER REEL #1
PO00015491 - BOOSTER REEL #1 DISCHARGE
A 1 1/2" booster reel discharge shall be plumbed from the pump to the booster reel.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 104 of 140 PO00015492 - BOOSTER REEL #1 DISCHARGE, PLUMBING, 1" HOSE The booster reel discharge shall be plumbed from the valve to the hose reel utilizing 1" hose. The end of the hose connected to the hose reel shall be equipped with a swivel end for ease in hose replacement.
PO00007275 - 1-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE BOOSTER REEL A 1 1/2" Akron, #8800 series, full flow, stainless-steel ball valve shall be provided for the booster reel #1 discharge.
PO00007282 - PUSH/PULL CONTROL FOR BOOSTER REEL #1
The booster reel discharge valve shall be controlled by a push/pull handle located on the operator's panel.
PO00007305 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - BOOSTER REEL #1 The booster reel discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.
To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.
A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.
The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00007308 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red. ***SPECIAL: SP00037842 - BOOSTER REEL #1 - HANNAY ALUMINUM BOOSTER REEL #1 One (1) Hannay, aluminum, Super Booster, electric rewind booster reel shall be furnished.
The reel shall be equipped with a one (1) inch 90 full flow swivel joint and an adjustable brake for freewheeling, drag or full lock operation.
Reel model shall be 30-20-24 with NPSH threads.
PO00007315 - BOOSTER REEL #1 LOCATED ABOVE PUMP ENCLOSURE - OFFICER SIDE The booster reel #1 shall be mounted above the pump enclosure towards the officer side of the unit.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 105 of 140 ***SPECIAL: SP00037841 - BOOSTER REEL COVER
The booster reel shall be enclosed in a 3/8" tread plate cover with hose roller guides exiting on the O/S of the dunnage area. Note: the booster reel enclosure shall be sturdy enough to be used as a stepping surface and hinged to allow for hose to be changed out. One (1) Tecniq E18 LED light shall be provided inside the enclosure activated by opening the upper door.
PO00007321 - HOSE REEL #1 REWIND OFFICER'S SIDE PUMP PANEL Booster reel rewind shall be controlled by a pump panel mounted push button on the officer's side panel.
The booster reel circuit shall be equipped with a shielded toggle switch to act as a booster reel disconnect to avoid accidental actuation of the booster reel rewind button. ***SPECIAL: SP00025691 - BOOSTER REEL #1 HOSE, 150 FEET OF 1" HOSE W/NPSH COUPLINGS Each booster reel shall be equipped with 150' of 1" booster hose in (1) 100' section and (1) 50' section.
Each length shall be fitted with NPSH couplings.
***SPECIAL: SP00008488 - BOOSTER HOSE NOZZLE
One (1) Task Force 1040 nozzle with bale and handle, for booster reel shall be provided. Thread to be NPSH.
No holder will be provided.
PO00007348 - CAPTIVE HOSE ROLLER ASSEMBLY FOR SIDE OF PUMP PANEL A captive roller arrangement shall be provided around the perimeter of the opening at the dunnage area allowing hose to be pulled out in any direction.
PO00007450 - FOAM SYSTEM STAINLESS PIPING - 1 INCH FROM FOAM SOURCE TO SYSTEM All foam concentrate plumbing from the tank or auxiliary foam inlet to the foam system components shall be stainless-steel and nonferrous material.
The foam system piping shall incorporate a check valve to prevent water from entering the foam tank; the discharge piping shall also include a check valve to prevent foam solution from back feeding into the discharge side of the pump.
Individual discharge piping shall be as specified for each discharge.
The complete foam system shall be tested in accordance with NFPA-1901.
PO00007474 - FOAMPRO 2001 CLASS "A AND/OR B" FOAM SYSTEM A FoamPro model 2001, electronic, fully automatic, variable speed, direct injection, discharge side foam proportioning system shall be installed in the pumping system.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 106 of 140 The system shall be capable of handling Class "A" foam concentrates and most Class "B" foam concentrates.
The foam proportioning operation shall be based on direct measurement of water flows and remain consistent within the specified flows and pressures.
System must be capable of delivering accuracy to within 3% of calibrated settings over the advertised operation range when installed according to factory standards.
The system shall be equipped with a digital electronic control display suitable for installation on the pump panel.
Incorporated within the control display shall be a microprocessor that receives input from the system flow meter, while also monitoring foam concentrate pump output, comparing values to ensure that the operator preset proportional amount of foam concentrate is injected into the discharge side of the fire pump.
A paddlewheel-type flow meter shall be installed in the discharge or manifold system specified to be foam capable.
A Full flow check valve shall be provided to prevent foam contamination of fire pump and water tank or water contamination of foam tank.
A 12 or 24-volt electric motor drive positive displacement foam concentrate pump, rated up to 2.5 GPM (9.5 L/min) @ 150 psi with operating pressures up to 400 psi (27.6 BAR), shall be installed in a suitable, accessible location.
The system shall draw a maximum of 40 amps @ 12 VDC or 21 amps @ 24 VDC.
A pump motor electronic driver (mounted to the base of the pump) shall receive signals from the computer control display and power the 1/2 hp (0.40 Kw) electric motor directly coupled to the concentrate pump in a variable speed duty cycle to ensure that the correct proportion of concentrate preset by the pump operator is injected into the water stream.
The digital computer control display located on the pump operator's panel shall enable the pump operator to perform the following control and operation functions for the foam proportioning system:
• Provide push-button control of foam proportioning rates from 0.1% to 9.9%, in 0.1% increments • Show current flow-per-minute of water
• Show total volume of water discharged during and after foam operations are completed • Show total amount of foam concentrate consumed
• Simulate flow rates for manual operation
• Perform setup and diagnostic functions for the computer control microprocessor • Flash a low concentrate warning when the foam concentrate tank(s) runs low • Flash a no concentrate warning and shut the foam concentrate pump off, preventing damage to the pump, should the foam tank(s) empty
The digital computer control display shall interface with the options listed; provide dual foam calibration and display separate totals for each foam concentrate used.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 107 of 140 If two foam tanks are required and piped to the foam concentrate pump, either an electric dual tank valve or the manual dual tank valve shall be provided.
Components of the complete proportioning system shall include:
• Operator control and display
• Paddlewheel flow meter
• Pump and electric motor/motor driver
• Wiring harnesses
• Low-level tank switch (Switches)
• Electronic dual tank valve or manual dual tank valve (if more than one tank) • Foam injection check valve
• Main waterway check valve
Accurate concentration proportioning can be achieved, based on the following water flows:
• 85 GPM water 3.0% concentration
• 260 GPM water 1.0% concentration
• 520 GPM water 0.5% concentration
• 1300 GPM water 0.2% concentration
Note: Multiple discharges plumbed to this system may affect performance if the flow rates are exceeded by any one discharge or the totality of multiple discharges at one time! PO00007498 - INJECTION SYSTEM DISCHARGE PLUMBING
The discharge piping shall be equipped with a properly sized flow meter sensor, based on the systems capabilities.
The foam system shall be plumbed to the following discharge/s through the discharge piping or manifold system:
PO00009151 - INJECTION FOAM SYSTEM INSTALLED ON CROSSLAY #1 Crosslay #1 discharge.
PO00009152 - INJECTION FOAM SYSTEM INSTALLED ON CROSSLAY #2 Crosslay #2 discharge.
PO00009153 - INJECTION FOAM SYSTEM INSTALLED ON CROSSLAY #3 Crosslay #3 discharge.
PO00009155 - FOAM SYSTEM INSTALLED ON FRONT DISCHARGE
Front discharge.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 108 of 140 PO00009164 - INJECTION FOAM SYSTEM INSTALLED ON HOSEREEL # 1 Hose reel # 1 discharge.
PO00022343 - CLASS A - PHOS-CHEK WD881 BY MONSANTO
Class A – Phos-Chek WD881 manufactured by Monsanto.
PO00022367 - CLASS B - OTHER (MUST SPECIFY FOAM NAME AND MANUFACTURER) - TBD @ PRE-CON Class B - OTHER - (MUST SPECIFY FOAM NAME AND MANUFACTURER).
PO00022762 - INJECTION FOAM SYSTEM INSTALLED ON DRIVER SIDE HOSEBED DISCHARGE #1 Drivers side hosebed discharge #1
PO00022776 - INJECTION FOAM SYSTEM INSTALLED ON OFFICER SIDE HOSEBED DISCHARGE #1 Officers side hosebed discharge #1
PO00023607 - INJECTION FOAM SYSTEM INSTALLED ON OFFICER SIDE HOSEBED DISCHARGE #2 Officers side hosebed discharge #2
PO00010791 - PUMP INSTALLATION - CUSTOM
PO00009801 - SIDE MOUNT PUMP MODULE
The pump module shall be a self-supported structure mounted independently from the body and chassis cab.
The design must allow normal frame deflection without imposing stress on the pump module structure or side running boards. The pump module shall be securely mounted to the chassis frame rails.
PO00000005 - PUMP MODULE - STEEL CONSTRUCTION
The pump module shall be a welded framework utilizing structural steel components properly braced to withstand the rigors of chassis frame flex.
***SPECIAL: SP00037827 - SIDE MOUNT DUNNAGE AREA
A dunnage area shall be provided above the pump enclosure for equipment mounting and storage. This area shall be furnished with a removable 3/16" tread plate floor and shall be enclosed on the sides.
The inside and outside of the side dunnage area walls shall be painted job color.
NOTE: The size of this storage area may vary when top mounted crosslays, booster reel(s), etc., are specified and located in this area.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 109 of 140 PO00011571 - RUNNING BOARD STEPS (NON-AERIALS)
The driver and officer running board steps shall be fabricated of 3/16" tread plate.
The outside edge on each step shall be fabricated with a double break, return flange.
The steps shall be rigidly reinforced with a heavy-duty support structure.
The running boards shall not form any part of the compartment design and shall be bolted into place with a minimum 1/2" clearance gap between any panel to facilitate water runoff.
PO00011575 - STORAGE WELL IN OFFICERS SIDE RUNNING BOARD (FLOATING) A floating storage well, constructed of 1/8" aluminum, shall be recessed into the officer’s side running board.
The storage well shall measure 9" deep x 9" wide x as long as possible between the running board support members.
Drain holes shall be located in the bottom corners to allow water to drain from the storage well.
The front and rear bottom corners of the well shall have an angled face to help the well slide up if it strikes an object.
The entire well shall be a "floating" style that can easily shift up if an object is struck.
PO00026070 - TWO (2) LEVER STYLE STRAPS ON OFFICER'S STORAGE WELL The officer's side running board hose well shall be furnished with lever style straps with 2" webbing to secure the hose stored in the well.
The straps shall be attached to each side of the hose well with stainless-steel footman loops.
PO00011591 - OFFICER'S SIDE WELL - GENERAL STORAGE
The officer's side storage well shall be utilized for general storage of tools or equipment, the well shall be a large as space allows.
PO00011610 - STORAGE WELL IN DRIVERS SIDE RUNNING BOARD (FLOATING) A floating storage well, constructed of 1/8" aluminum, shall be recessed into the driver’s side running board.
The storage well shall measure 9" deep x 9" wide x as long as possible between the running board support members.
Drain holes shall be located in the bottom corners to allow water to drain from the storage well.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 110 of 140 The front and rear bottom corners of the well shall have an angled face to help the well slide up if it strikes an object.
The entire well shall be a "floating" style that can easily shift up if an object is struck.
PO00026071 - TWO (2) LEVER STYLE STRAPS ON DRIVER'S STORAGE WELL The driver's side running board hose well shall be furnished with lever style straps with 2" webbing to secure the hose stored in the well.
The straps shall be attached to each side of the hose well with stainless-steel footman loops.
PO00011626 - DRIVER'S SIDE WELL - GENERAL STORAGE
The driver's side storage well shall be utilized for general storage of tools or equipment, the well shall be a large as space allows.
PO00009800 - SIDE MOUNT PUMP PANEL
The pump operator's control panel shall be located on the driver side of the apparatus.
The pump enclosure side panels shall be completely removable and designed for easy access and servicing. ***SPECIAL: SP00020053 - PUMP PANEL APPROVAL DRAWING
A pump panel approval drawing will be provided.
PO00000095 - SIDE MOUNT PANELS - BLACK LINE-X COATED
The left side operator's panel, gauge panel, right side pump panel, and right-side access door shall be fabricated from 1/8" aluminum.
It will also be coated with black Line-X material. The Line-X material shall provide a heavy-duty textured finish.
PO00000128 - VERTICALLY HINGED GAUGE PANEL - SIDE MOUNT A full width, vertically hinged gauge access panel shall be provided at the operator's position.
Chrome plated positive locks shall be provided along with chain holders to prevent the front of the gauge panel from coming in contact with other panels when open.
PO00000132 - OFFICER SIDE VERTICALLY HINGED PUMP ACCESS DOOR - SIDE MOUNT The officer's side pump panel shall be split and vertically hinged to provide complete access to the pump and plumbing on the officer's side of the pump enclosure.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 111 of 140 The panels shall be equipped with stainless-steel hinges and secured with push type locks to hold the panels closed.
The drains located on the officer's side panel shall be fastened to the lower panel, which shall be stationary.
PO00010829 - PANEL FASTENERS
Stainless-steel machine screws and lock washers shall be used to hold these panels in position.
The panels shall be easily removable to provide complete access to the pump for major service.
PO00010830 - CAPS AND ADAPTERS SAFETY TETHER - BALL CHAIN All applicable discharge and suction caps, plugs and adapters shall be equipped with chrome plated ball chain and secured to the vehicle.
PO00010832 - PUMP PANEL DISCHARGE/SUCTION TRIM PLATES, HIGH POLISHED A high polished trim plate shall be provided around each discharge port and suction inlet opening to allow accessibility to the respective valve for service and repairs.
PO00010833 - DISCHARGE GAUGE TRIM BEZELS
Each individual discharge gauge shall be installed into a decorative chrome-plated mounting bezel that incorporates valve-identifying verbiage and color labels, unless manufacturer supplied otherwise.
PO00010834 - IDENTIFICATION PLATES
Color coded identification tags shall be provided for all gauges, controls, connections, switches, inlets and outlets.
PO00012157 - PUMP OPERATOR'S PANEL, FULL WIDTH LIGHT SHIELD/STEP The pump operator’s panel shall be equipped with a light shield/step that shall be full width of the control panel and shall be positioned to cover the lights and prevent glare.
The light shield shall be fabricated from tread plate, which shall also serve as a step.
The step shall be a minimum of 8" deep X the width of the pump panel. (Note: On apparatus with lowered style crosslays, the light shield shall be from the back of the crosslays to the rear of the pump house).
The light shield shall be equipped with the following lights:
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 112 of 140 PO00012171 - TECNIQ E18 LED LIGHTS - LIGHT SHIELD/STEP
Four (4) Tecniq #E18 LED lights.
One (1) light under the operator's panel light shield shall be actuated when fire pump is engaged in addition to the pump engaged light.
PO00012175 - TECNIQ EON 3 LED LIGHTS - OFFICER SIDE PUMP PANEL Four (4) Tecniq Eon, 3-LED illumination lights mounted in horizontal stainless-steel bezels and mounting gaskets.
The lights shall be switched with the main pump panel lights.
PO00012573 - AIR HORN CONTROL BUTTON ON PUMP PANEL
Pump panel air horn actuation button labeled "EVACUATION" in white letters with a red background.
PO00012578 - 3/4" PUMP BY-PASS COOLER ON PUMP PANEL
3/4" Pump cooler (Bypass Line).
PO00012579 - AIR INLET/OUTLET ON RIGHT SIDE PUMP PANEL
Air inlet/outlet chuck (right side panel).
PO00011409 - PUMP PRESSURE & VACUUM TEST PORTS @ PANEL
The pump panel shall be equipped with Vacuum Pressure test plugs to allow for test equipment to monitor pump pressure and vacuum levels.
Chrome plugs and labels shall be provided for the test ports.
PO00011425 - 4-1/2" CLASS ONE, LIGHTED, MASTER PRESS. AND COMPOUND GAUGES One (1) 4-1/2" diameter pressure gauge (labeled: "PRESSURE") and one (1) 4-1/2" diameter compound vacuum gauge (labeled: "INTAKE") shall be provided.
The master gauges shall be Class One and shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.
The gauge face shall be white with black numerals.
PO00011432 - 4-1/2" BLUE ILLUMINATED GAUGES - CLASS ONE Both gauges shall be Blue.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 113 of 140 PO00011442 - PRESSURE & COMPOUND GAUGE RANGES - SINGLE STAGE All applicable pressure gauges shall have a range of 0 - 400 P.S.I., and the compound gauge shall have a range of -30" - 0 - 400 P.S.I.
PO00025813 - PUMP THIRD PARTY CERTIFICATION - 750 GPM & UP The pump shall be third party performance tested to meet the requirements of NFPA-1901. There will be no exceptions.
PO00007673 - WATER TANK 500-GAL POLY
The water tank shall have a capacity of 500 gallons, constructed from Poly material.
PO00010842 - WATER TANK FILL TOWER POLY
The tank shall have a combination vent and manual fill tower.
The fill tower shall be constructed of 1/2" PT3 polypropylene and shall be a minimum dimension of 8" x 8" outer perimeter.
The fill tower shall be blue in color indicating that it is a water-only fill tower.
The tower shall have a 1/4" thick removable polypropylene screen and a PT3 polypropylene hinged cover.
The capacity of the tank shall be engraved on the top of the fill tower lid. Inside the fill tower there shall be a combination vent/overflow pipe.
The vent overflow shall be a minimum of schedule 40 polypropylene pipe with a minimum I.D. of that is designed to run through the tank and shall be piped to discharge water behind the rear wheels as required in NFPA 1901 so as to not interfere with rear tire traction.
PO00007665 - WATER TANK 4" OVERFLOW & VENT PIPE
The fill tower shall be fitted with an integral 4" I.D. schedule 40 P.V.C. combination overflow/vent pipe running from the fill tower through the tank to a 4" coupling flush mounted into the bottom of the tank to allow water to overflow behind the chassis rear axle.
PO00026282 - WATER TANK 3" SUMP DRAIN W/ 2" PUSH-PULL AT PUMP PANEL A 2" drain valve with a push/pull handle on the pump panel shall be provided.
PO00009185 - INTEGRAL FOAM TANK, 30 GAL. TANK "A"
Included in the total capacity of the water tank, a 30-gallon integral foam storage area shall be built into the water tank.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 114 of 140 The foam tank shall have a latched fill tower, properly labeled as the foam fill point.
A valved drain shall be provided.
PO00009188 - INTEGRAL FOAM TANK, 10 GAL. TANK "B"
Included in the total capacity of the water tank, a 10-gallon integral foam storage area shall be built into the water tank.
The foam tank shall have a latched fill tower, properly labeled as the foam fill point.
A valved drain shall be provided.
PO00007589 - CLASS ONE "ITL-40M" LED TANK LEVEL GAUGE - PUMP The water tank shall be equipped with a Class 1, model # ITL-40M, water tank level gauge for indicating water level on the pump operator's panel.
The tank level gauge shall indicate the liquid level on a easy to read LED display and show increments of 1/8 of a tank.
PO00007595 - CLASS ONE WATER LEVEL - 1/4" NPT PRESS TRANS @ BOTTOM TANK The gauge shall use a pressure transducer installed near the bottom of the water tank to determine the correct volume in the tank.
PO00023600 - CLASS ONE RELAY DRIVER
A Class One remote relay module shall be provided to provide outputs for large indicator lights on the side of the vehicle.
PO00007605 - MONSTER WATER LEVEL GAUGE, EA. SIDE OF CAB - WHELEN PSTANK2 A large light water level gauge system shall be provided on both sides of the cab. Each side shall have a Whelen model PSTANK2, LED strip light, surface mounted, behind the rear crew door above the handrail.
The strip light shall indicate the following water levels:
• Green LED cluster Full tank
• Blue LED cluster 3/4 tank
• Amber LED cluster 1/2 tank
• Red LED cluster 1/4 tank
The red LEDs shall burn steady to indicate 1/4 tank and shall start to flash when the water level drops below 1/4 tank. To prevent distraction to drivers, this tank level gauge shall be wired to display only when the park brake is engaged.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 115 of 140 PO00007637 - CLASS ONE "ITLF-40M" LED FOAM TANK LEVEL GAUGE - TANK "A" The foam tank shall be equipped with a Class 1, model # ITLF-40M, Itelli-Tank foam level gauge for indicating foam level on the pump operator's panel.
The tank level gauge shall indicate the liquid level on a easy to read LED display and show increments of 1/8 of a tank.
***SHOP NOTE: SR00153140 - FOAM TANK LEVEL GAUGE LABELING The foam tank level gauge labels will read "A" and "B" with no capacity, "A" tank tag color will be red and "B" tank tag color will be green.
PO00007642 - CLASS ONE FOAM LEVEL - 1/4" NPT PRESS TRAN @ BOTTOM TANK "A" The gauge shall use a pressure transducer installed near the bottom of the foam tank to determine the correct volume in the tank.
PO00007651 - CLASS ONE "ITLF-40M" LED FOAM TANK LEVEL GAUGE - TANK "B" The foam tank shall be equipped with a Class 1, model # ITLF-40M, Intelli-Tank foam level gauge for indicating foam level on the pump operator's panel.
The tank level gauge shall indicate the liquid level on a easy to read LED display and show increments of 1/8 of a tank.
PO00007658 - CLASS ONE FOAM LEVEL - 1/4" NPT PRESS TRAN @ BOTTOM TANK "B" The gauge shall use a pressure transducer installed near the bottom of the foam tank to determine the correct volume in the tank.
PO00009849 - FOAMPRO MANUAL DUAL TANK SELECTOR, A & B FOAM TANKS A FoamPro Model 3435-0079, panel mounted, manual dual tank selector valve which provides a water flush when switching between the tank selection shall be provided to allow the use of Class "A" or "B" foam tanks.
This item selection includes one (1) low level sensor and one (1) "Y" strainer for the additional foam tank configuration.
PO00009857 - HALE EZ-FILL FOAM TANK REFILL SYS - DUAL TANK The apparatus shall be equipped with a Hale EZ-Fill foam transfer system for refilling the on-board foam cells.
The system operates by attaching a suction hose to a pre-plumbed panel connection using a positive seal quick connect fitting.
The pickup wand is then placed in the foam concentrate container.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 116 of 140 EZ-Fill is an easy-to-operate fixed-mount 12-volt, 5-gpm foam tank refill pump system.
EZ-Fill features push-button smart switch technology.
Just press the “Fill” or “Flush” button for a moment and the unit shall cycle either filling the foam concentrate reservoir or running through a flush cycle.
***SPECIAL: SP00008493 - 1" FOAM TANK DRAIN BEHIND OFFICER SIDE PUMP PANEL A 1" line from the foam tank shall be provided in order to drain foam from the tank. The line shall terminate behind the officer's side pump panel with a quarter turn drain valve.
The foam system shall have a shut off valve at the strainers to service the foam system. The foam shut off valve must be easily accessible to reach from the pump access door.
PO00009795 - APPARATUS BODY GENERAL DESCRIPTION (PUMPER) The body side and compartment assemblies shall be designed and assembled to provide maximum strength and durability under all operating conditions. Special attention shall be taken to minimize corrosion on all fabricated parts and structural members of the body. All bolt-on components shall be provided with a dissimilar metals isolation barrier to prevent electric corrosion.
The body design shall also incorporate removable panels to access spring hangers, rear body mounts and fuel tank sending units. The body assembly shall be an all-welded configuration. The body shall be completely isolated from the cab and pump module structure.
Dimensions used in this specification shall be the general outer dimension taken from a typical line diagram of the apparatus. These dimensions shall not take into account items like material thickness, access panels, doors, and other installed options.
***SPECIAL: SP00008515 - 100" WIDE BODY, 26"/14" DEEP SIDE COMPARTMENTS The fire body shall be 100" wide to provide the maximum amount of usable hose bed and compartment space.
The side body compartments shall be 26" deep in any full depth areas and 14" deep in any split depth areas.
PO00009804 - SWEEP-OUT COMPARTMENTS (NON-AERIALS)
Compartment floors shall be welded to the compartment walls and have a sweep out design for easy cleaning.
Compartments with hinged doors shall have the door opening flanges bend down to produce the sweep-out design.
Compartments with roll-up style doors shall have the external floor flange stepped down to produce a sealing surface for the roll-up doors below the compartment floor.
The sweep out design shall also permit easy cleaning.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 117 of 140 PO00010883 - FASTENERS
FASTENERS
All exterior fasteners shall be stainless-steel screws.
NOTE: The use of aluminum pop rivets or self-tapping screws as a trim fastener shall not be acceptable.
PO00010884 - COMPARTMENT LOUVERS
Ventilation between compartments to atmosphere shall be provided and located to avoid water entry into compartments.
PO00010886 - LOUVER FILTERS
To minimize dust and dirt from drafting into the compartments through the compartment louver, each louver shall be equipped with a filter material mounted on the exterior of the louver.
PO00010885 - ACCESS PANELS
Removable access panels shall be provided (if applicable) to access fuel tank sender, electrical junction compartment and rear body mounts.
Protective panels shall be located in the rear compartments providing access to the lights and associated wiring.
The covers shall also serve as protective covers to prevent inadvertent damage to lights or wiring from tools or equipment located in the compartment.
PO00000142 - BODY MATERIAL: 12 GAUGE GALVANNEAL STEEL
The body shall be assembled in fixtures to ensure accurate body dimensions and door openings. The parts used in the construction of the body weldment shall be fabricated from the highest, Grade 12 gauge galvanneal steel (ASTM A653) and will have a coating weight of A-60. After proper alignment is achieved, the body panels shall be spot-welded together to ensure proper weld penetration and then stitch-welded on all exposed seams to minimize distortion of welded assemblies. A full seam weld shall not be used due to the applied heat which shall distort sheet metal and remove the protective coating from the perimeter of the welded area. All seams shall be caulked prior to paint being finished for proper compartment seal.
PO00024374 - BODY SUBFRAME - STEEL
The body sub structure shall be an all-welded configuration utilizing a combination of 3” x 1-1/2” A500 Gr. B structural tubing and A36 structural channel.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 118 of 140 The sub structure shall be designed to totally support the full length and width of the body. The structure shall be welded to the body side compartments to incorporate the compartments into an integral part of the body weldment.
All cross tubes of the structure shall be capped, and butt welded at their point of termination to prevent water from lying inside the super structure. The super structure shall be bolted to the sides of the chassis frame at four (4) points. The two (2) forward mounting points shall utilize a spring mount to help isolate the body from chassis deflection.
This design shall provide storage capacity in each side compartment for a minimum of 500 lbs. of equipment, and a minimum of 1000 lbs. of equipment in the rear step compartment. ***SPECIAL: SP00033479 - 61" WIDE FENDER - CUSTOM
The body fender shall be 61" long, this shall allow for the suspension and related components to be contained within the fender, preventing any intrusion into the body compartment storage area. Bodies with notches in the front and/or rear compartment for suspension components are not acceptable. There will be no exceptions. ***SPECIAL: SP00037839 - AIR BOTTLE STORAGE COMPARTMENTS A total of six (6) SCBA air bottle storage compartments 26" deep shall be provided in the rear body fender areas. The driver side compartments shall include one (1) double bottle storage compartment to the rear of the wheels, and (1) single compartment on the forward area. The officer side compartments shall include one (1) double bottle storage compartment to the rear of the wheels, and (1) single compartment on the forward area. Note: The double compartment will have a triangular center partition.
Each storage compartment shall be equipped with a painted door that shall be tied to the "Do Not Move Apparatus" warning system.
Clarification: The fender storage doors will have the Southco ring style latch Southco M1-25-61-28 flush mount stainless-steel latch.
PO00009648 - FENDER WITH STORAGE OPTIONS (CUSTOM)
PO00000147 - MEDIUM PUMPER BODY
***SPECIAL: SP00037893 - 143" DS LOW SIDE / HIGH SIDE
One (1) low side compartment shall be provided forward of the rear wheels, measuring 34" high x 31" wide with an opening of 31" high x 28" wide.
One (1) low side compartment shall be provided to the rear of the rear wheels, measuring 34 high x 33" wide with an opening of 31" high x 30" wide.
One (1) high side compartment shall be provided above the lower compartments and the rear wheels, measuring 34" high x 122" wide with two (2) openings of 31" high x 58" wide each.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 119 of 140 ***SPECIAL: SP00037894 - 143" OS LOW SIDE / HIGH SIDE
One (1) low side compartment shall be provided forward of the rear wheels, measuring 34" high x 31" wide with an opening of 31" high x 28" wide.
One (1) low side compartment shall be provided to the rear of the rear wheels, measuring 34" high x 33" wide with an opening of 31" high x 30" wide.
Two (2) equipment compartments shall be provided above the lower compartments, one to each side of the center mounted overhead ladder rack arm. The compartments shall measure 34" high x 50" wide respectively with openings of 31" high x 47" wide respectively.
The officer side lower (EMS) compartment behind the wheel will be provided with a remote unlock push button inside the cab. The button will be located next to the officer side forward facing crew seat and will be labeled Lock\Unlock and illuminated if possible.
The lock switch will be wired HOT to the battery.
A hole will be provided under the compartment door lock to manually unlock the door in the event of an electric lock failure.
***SPECIAL: SP00037896 - FULL HEIGHT BEAVERTAIL STORAGE COMPARTMENTS Each side rear body corner will be equipped with a full height, externally accessed, beavertail storage compartment 68" high x 15" wide x 26" deep at the lower 32" and 14" deep at the upper 36" with a roll up door opening approximately 65" high x 12" wide. The rear 6" of these compartments will be 14" deep to accommodate the 72" wide rear step.
***SPECIAL: SP00037834 - TRANSVERSE LOCKER COMPARTMENT, 24" W X 56" H X 16" A transverse locker compartment shall be provided in front of the pump enclosure, one (1) each side measuring 24" wide x 56" high x 16" deep / transverse above the frame rails with a door opening of 17" wide x 54" high.
The compartment shall be transverse over the frame rail.
There will be a 5" forward door post to clear the telescoping lights. The compartment will have a 1" thick door held open by gas struts with a D-ring handle.
Note: The transverse portion of this compartment shall have a 6" recessed area in the center 34" to accommodate cross lay plumbing.
***SPECIAL: SP00037898 - INTERMEDIATE REAR STEP COMPARTMENT An intermediate rear compartment shall be provided above the rear step compartment. The compartment shall be approximately 26" deep x as wide and tall as possible.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 120 of 140 The compartment shall include a smooth aluminum top hinged door with two (2) thumb latches and gas shock stay arms. The door shall include chevrons to match the color and design of the specified rear chevrons.
The door shall be wired into the "do not move circuit". ***SPECIAL: SP00037899 - ISOLATED REAR STEP COMPARTMENT An isolated rear step compartment measuring approximately 36" high x 48" wide x 32" deep with a door opening of 34" high x 45-1/2" wide shall be provided at the rear of the apparatus.
PO00000200 - REAR STEP COMPARTMENT - FULL SIDE WALLS
The rear step compartment shall have full side panels which will isolate the storage area from the side body compartments.
PO00000203 - REAR STEP COMPARTMENT - ROLLUP DOOR
The rear step compartment shall be equipped with a roll up style door.
PO00024176 - REAR BODY DOOR FINISH - SATIN
The rear body door shall have a satin finish.
PO00024179 - REAR BODY DOOR RAIL FINISH - SATIN
The rear body door rails shall have a satin finish.
***SPECIAL: SP00037897 - KEYED DOOR LOCKS, HINGED OR ROLL-UP DOORS Thirteen (13) compartment door(s) shall be equipped with keyed locking door latches (six (6) compartment doors on each side, plus the rear step compartment roll up door). Two keys shall be furnished for each lock and shall be labeled to indicate the correct match.
Twelve (12) of the specified door lock cylinders shall be equipped with a #1250 key, and the officer side lower rear body compartment shall be equipped with a #751 key.
In additional, the officer’s side lower rear compartment shall be equipped with an electronic lock provided by the roll up door manufacturer. The switch to unlock the compartment door shall be located inside the cab, in the rear crew area next to the fold down seat on the officer’s side adjacent to the back wall.
PO00010936 - ROLL-UP DOORS
Roll-up doors shall be provided on all compartments.
The roll-up doors shall be constructed from aluminum extruded slats which shall have a flexible seal between each slat for proper sealing of the door.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 121 of 140 A synthetic rubber seal shall be provided at each side, top and bottom edge of the door to prevent entry of dirt into the compartment.
The door shall be equipped with a lift bar style latch mechanism which shall latch at the bottom of the door mounting extrusion.
The roll-up door assembly shall be furnished with a spring-loaded, counterbalance assembly to assist in door actuation.
All running board and high side compartments shall be equipped with roll-up doors.
PO00000286 - AMDOR ROLL-UP DOORS, PAINTED FINISH
The roll-up doors shall be made of Amdor brand. The doors shall be painted to match the required color of the fire department.
PO00009734 - PAINTED ROLLUP DOORS - PAINTED CURTAIN, TOP GUTTER The top gutter and side frames shall be painted to match the required color of the fire department.
PO00000288 - KEY MODEL #1250
The specified door lock cylinder shall be equipped with a #1250 key.
PO00024098 - REAR COMPARTMENT DOOR MANUFACTURER - AMDOR The rear compartment door brand shall be Amdor.
PO00010859 - COMPARTMENT TOPS
Compartment ceilings shall be a fully welded design as part of the body construction process.
Compartment designs that do not have a welded in ceiling and utilize the stepping surface overlay as the ceiling shall not be acceptable. {No Exceptions}
The top of the welded in compartment ceiling shall be overlaid with tread plate to provide an NFPA compliant stepping surface.
There will be no exceptions.
PO00010862 - REAR BODY PANEL
The rear body panel shall extend the full width between the body side compartments.
This panel shall be full height from the rear step to the hose bed floor.
No part of the rear panel shall be attached to the booster tank.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 122 of 140 The rear body panel material shall be tread plate as standard.
If Chevron striping is specified for the rear of the body then smooth aluminum shall be utilized.
PO00009806 - STAINLESS DOOR SILL PROTECTORS INSIDE ALL BODY A 90 deg angle door sill protector, fabricated from 18 gauge brushed finish stainless-steel shall be installed on the bottom external edge of each body compartment door opening to help protect this area from paint chipping.
PO00012483 - TREAD PLATE OVERLAY, FRONT OF SIDE COMPARTMENTS (WRAP AROUND) The front face of the side compartments, next to the driver and officer side pump panels shall be overlaid with tread plate full height protection.
The protection panel shall cover the entire front face of the compartment and shall wrap around the corner to the door opening.
PO00000290 - BODY RUB RAILS, TREAD PLATE
Sacrificial, tread plate, rub rails shall be mounted at the base of the body, extending outward a minimum of 3/4", downward 2", and flange inward 1". The rub rails shall extend the full length of the main body and out to the rear step or wrap around the corners. Rub rails shall be bolted to the body from the bottom side of the compartment area, so that it does not damage the body side panels on initial impact and providing for ease of replacement.
PO00009797 - ALUMINUM WHEEL WELL LINERS
The body wheel wells shall be provided with fully removable bolt-in aluminum fender liners. The wheel well liners shall extend from the outer wheel well body panel into the truck frame. The completely washable wheel well liners shall be designed to protect the front and rear compartments and main body supports from road salts, dirt accumulation and corrosion.
PO00009703 - POLISHED ALUMINUM FENDERETTES, SINGLE AXLE BODIES The rear fenders shall be equipped with easily replaceable bolt-in polished aluminum fenderettes. The fenderettes shall be equipped with a rubber gasket molding between the body panel and the fender. ***SPECIAL: SP00008585 - I ZONE BRACKETS
A pair of I-Zone brackets will be installed on the beavertails of the unit. The brackets will be fabricated from Austin Hardware folding steps. When in the closed or opened position, the brackets will not extend beyond the side of the body.
The brackets will be installed below the rear scene lights one on each side. The bottom of the mounting plates will be 49" above the top surface of the rear step.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 123 of 140 PO00010934 - REAR MUD FLAPS
Heavy duty mud flaps shall be provided behind the rear wheels.
PO00000207 - RECESSED REAR STEP - 12 D X 72 W + 4 D X 100 W The rear step shall be a total of 16" deep, 12" recessed, and 4" extended. The recessed area of the step shall be 12" deep. The step must be recessed between the rear portion of the rear side compartments. The step shall be 72" wide in the recessed area and 100" wide in the extended area. The step shall be fabricated from 3/16" tread plate and shall be rigidly reinforced. The recessed design of the rear step shall reduce the rear side compartment depth to 14" deep in the rearmost 12" wide area of the compartment. The rear edge of the step shall be designed to accommodate the rear clearance lights. It will also be recessed for protection in the step reinforcement channel. The step shall be bolted into place with a minimum 1/2" clearance gap between the step and rear body panel.
The rear body beavertail area shall be furnished with a squared off appearance to maximize the available compartment area. The squared off appearance also provides additional support to the rear step structure.
The beavertail panels shall be assembled in conjunction with the rear body corner panels. This assembly shall provide a vertical mounting surface for taillights at the rear most portion of the body. In addition, storage space is also added to the assembly. The beavertails insides shall be furnished with tread plate overlays. ***SPECIAL: SP00008795 - INTERMEDIATE REAR STEP, 8" X FULL WIDTH An eight (8) inch deep formed intermediate rear step will be provided as an integral part of the rear body. The traffic advisor will be flush mounted into the rear body sheet above the intermediate rear step compartment.
PO00011555 - GRAB RAILS, KNURLED ALUMINUM EXTRUSION
All handrails shall be 1-1/4" outer diameter, knurled bright anodized aluminum extrusion, designed to meet NFPA 1901 requirements.
Molded gaskets shall be installed between the handrail stanchion castings and body surfaces to prevent electrolytic reaction between dissimilar metals and to protect paint.
Grab rails shall be provided at the following specified locations.
Additional grab rails shall be provided adjacent to any additional steps specified to comply with NFPA 1901.
PO00011563 - TWO (2) VERTICAL RAILS ON REAR
Two (2) vertical rails shall be mounted on the rear edge of the beavertails, one (1) each side. ***SPECIAL: SP00037887 - TWO (2) 12" HORIZONTAL HANDRAILS REAR TOP OF BODY Two (2) 12" horizontal handrails shall be provided and installed one (1) on each side at rear top of body.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 124 of 140 PO00011569 - HANDRAIL ABOVE PUMP PANEL, EACH SIDE
Two (2) horizontal handrails shall be mounted above each pump panel, (1) each side.
PO00011511 - INNOVATIVE CONTROLS LIGHTED STEP(S), BODY FRONT, DRIVER SIDE Innovative Controls large lighted folding step(s), with a textured chrome plate finish, shall be provided on driver side body front to provide NFPA compliant access (maximum 18” height between steps) to an upper horizontal walking surface (compartment cap, dunnage area, fabricated step, or upper body compartments).
PO00011496 - INNOVATIVE CONTROLS LIGHTED FOLDING STEP(S), BODY REAR DRIVER SIDE Innovative Controls large lighted folding step(s), with a textured chrome plate finish, shall be provided on driver side body rear to provide NFPA compliant access (maximum 18” height between steps) to an upper horizontal walking surface (compartment cap, dunnage area, fabricated step, or upper body compartments).
PO00011502 - NO FOLDING STEP(S), BODY REAR, OFFICER SIDE No folding steps shall be provided in this location.
PO00000317 - PAINTED REAR TOW EYES, BELOW BODY
Two (2) painted tow eyes shall be furnished on the rear of the vehicle. The tow eyes shall be made from plate steel and shall be bolted directly to the chassis frame rails with grade 8 bolts. The tow eyes will extend below the body. The tow eyes shall be smooth and free from sharp edges. They will have a minimum eyelet hole of 2-1/2". The tow eyes shall be painted.
PO00000217 - STANDARD BED - STANDARD COMPT CAPS (72")
The hose bed shall be located directly above the booster tank and be free from all sharp objects such as bolts, nuts, and so on, in avoidance of damage to a fire hose. For added strength, the hose bed side walls shall be approximately 2" thick, providing a mounting surface for devices such as warning and scene lights. The inner hosebed side walls shall be brushed aluminum panels, which will help prevent damage to painted surfaces when the hose is deployed. The front wall shall be flanged inward 2" with a 1" downward return, providing additional rigidity to the front wall.
PO00000226 - NFPA MINIMUM HOSEBED CAPACITY
The hose bed shall provide a minimum of 30 cubic feet hose storage area for 2-1/2" or larger fire hose in order to meet NFPA-1901 minimum pumper hose storage requirement. The apparatus weight analysis shall be based on 800’ of 2-1/2" hose, unless otherwise specified. If the hose load carried exceeds this minimum, the purchaser should advise the manufacturer prior to contract so that adequate chassis carrying capacity can be provided.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 125 of 140 PO00000228 - HOSEBED FLOORING - ALUMINUM SLATS
Flooring is to be constructed from extruded aluminum and have proper spaces for ventilation purposes. The flooring shall be smooth and free from sharp edges to avoid any hose damage. The hose bed floor shall be removable, providing access to the inner body framework. ***SPECIAL: SP00037836 - THREE (3) - 1/4" ADJUSTABLE HOSEBED PARTITIONS W/ NOTCHES Three (3) fully adjustable 1/4" aluminum hose bed partitions shall be provided. The partition shall be easily adjustable by channels, located at the front and rear of the hose bed. The partition shall be removable for access to the booster tank.
Each partition shall include an 8” deep notch on the bottom section of the partition at the hosebed wall to allow for ease of connection. Notches will be as high as the lower Unistrut.
PO00009735 - HOSEBED BLANK PANEL
A full width divider shall be installed in the hose bed located approximately 2" beyond the end of the water fill tower.
This divider shall be constructed of smooth aluminum and shall be fixed.
The adjustable hose bed dividers shall be installed up to this divider with the adjustment tracking attached to the fixed divider.
PO00009731 - TUBING REINFORCEMENT ON PARTITION(S) - 1-1/4" The top and rear edge of each of the hose bed partitions shall have a 1-1/4" integral tubing reinforcement welded on for additional support.
PO00009732 - HOSE PARTITION HANDHOLD CUTOUTS
The hose bed partition(s) shall have a vertical handhold cutout at upper rear edge of the partition. ***SPECIAL: SP00037868 - HOSEBED COVER - TREADPLATE COVER WITH FIXED CENTER DIVIDER An aluminum tread plate hose bed cover shall be mounted to the side body flanges utilizing a full-length stainless-steel hinge on each side. The cover shall be constructed of 3/16” aluminum tread plate with aluminum extrusion frame. The cover shall be supported by a fixed center partition which shall be 1-1/2” higher than the side body flanges to allow water runoff. The center hose bed fixed partition shall be notched at the lower rear to allow hose to be packed around the partition. The notch shall be 12” high X 6” deep.
Handles shall be provided at the rear for lifting. Gas springs and cables shall be provided at the front to hold open the doors. Note: The gas shocks for the hose bed covers shall be as strong as possible.
Switches shall be provided on each side cover, which shall be tied into the "Do Not Move Apparatus When Light Is On" warning light in the cab.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 126 of 140 A two (2) piece hinged access door shall be provided over the water tank fill tower area to allow access to the fill tower when the hose bed cover is in the closed position. The access door shall be hinged to the front to help prevent the door from opening when the apparatus is in motion. The split doors shall allow the driver side door to be opened when the ladder rack is in the stowed position. A single forward hinged flip up door will be provided in the driver's side door above the water fill tower.
There shall be an Amdor Luma bar light under the body flange in the water tower compartment.
Hose bed aluminum tread plate doors shall be provided with D-handles at the front and rear to assist with lifting.
The stay-open arms shall be provided with sleeves in place of release knobs. ***SPECIAL: SP00037835 - VINYL FLAPS AT REAR EDGE OF TREAD PLATE COVER W/ POSTMAN STRAPS Two (2) vinyl flaps at the rear of the tread plate hose bed cover. They shall be secured to the hose bed cover with quarter turn fasteners and secured at the bottom with postman straps.
PO00000254 - VINYL MATERIAL COLOR - BLACK
The vinyl material shall be black in color.
PO00009678 - ZICO "SINGLE ARM" HEAVY DUTY HYDRAULIC LADDER RACK (OFFICER SIDE) A hydraulically actuated, single arm, swing down ladder rack, for use with ladders that have a combined weight of approximately 500lbs., shall be provided. The ladders shall be stored horizontally, directly above the officer side compartments. The ladders shall be lowered and raised by means of a hydraulic actuator.
The ladders shall be stored on an 86" long cradle to retain the ladders with two (2) ladder retaining brackets mounted to hold the ladders with the rack down. The cradle shall be equipped with a forward and rear bumper stop, which shall be designed to contact the upper portion of the body to stabilize the ladder rack in the travel position.
The arm mechanism shall be constructed from 2" X 3" rectangular steel tubing arms with a square tubing framework to support the ladder storage angles. The pivot points of the arms shall be mounted with pins through a rigid aluminum casting to maintain structural integrity.
The actuator switch and power on/off switch for the ladder rack shall be located on the officer side pump panel area in an enclosed housing, to provide the operator full view of the rack during the raising or lowering operation. A warning alarm shall activate when the rack is in motion and shall be installed on the officer side rear body panel. An interlock system shall be provided whereas if any hinged compartment door on the officer side of the body is open, the rack shall not operate.
A flashing warning light labeled: "Do Not Move Apparatus When Light Is On", shall be provided on the cab dash to indicate when the rack is not in the raised travel position.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 127 of 140 The forward and rear ends of the ladder rack shall be equipped with flashing lights to warn when the rack is down. The lights shall be amber on the front and red on the rear and shall automatically activate when the rack is not locked in the travel position.
An automatic lock shall be provided for the ladder rack in the nested position that shall automatically engage when the ladder rack is nested.
PO00009682 - ZICO SINGLE ARM RACK - LOCATED IN CENTER POSITION The specified single arm ladder rack shall be located in the center mounting position on the body side.
This mounting shall split the specified high side compartment into two separate compartments, and reduce the overall width by 17".
The 17" void shall be taken from the center section of the high side compartment, and two (2) equally sized doors shall be installed on the high side compartments.
PO00009684 - SINGLE ARM LADDER RACK - PAINTED HYDRAULIC COVER A painted cover shall be installed to cover the hydraulic cylinder actuator arm. The cover shall be painted job color of the body and shall be actuated automatically with operation of the ladder rack.
PO00008997 - DUO-SAFETY 900-A 24' 2-SECTION EXTENSION LADDER (ALUMINUM) A Duo-Safety series 900-A, 24', aluminum, two (2) section extension ladder shall be provided.
PO00009017 - DUO-SAFETY 775-A 14' ROOF LADDER W/ FOLDING HOOKS (ALUMINUM) A Duo-Safety series 775-A, 14', aluminum, straight roof ladder with folding hooks shall be provided.
PO00000401 - DUO-SAFETY 585-A 10' FOLDING ATTIC LADDER (ALUMINUM) A Duo-Safety series 585-A, 10', folding, aluminum, attic ladder shall be provided.
PO00019830 - 1/2 DEPTH ADJUSTABLE SHELF DESCRIPTION - RESCUE Compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2” upward bend at front and rear, and side supports. Shelving shall be vertically adjustable with spring nuts in aluminum strut channel.
Half depth adjustable shelves shall be located as indicated at each compartment description.
PO00019874 - 1/2 DEPTH ADJUSTABLE SHELF(S) LOCATED R-4
Located in the right side compartment #4
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 128 of 140 PO00019887 - ADJUSTABLE SHELF DESCRIPTION - RESCUE
Compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2” upward bend at front and rear, and side supports. Shelving shall be vertically adjustable with spring nuts in aluminum strut channel.
Adjustable shelves shall be located as indicated at each compartment description.
PO00019932 - ADJUSTABLE SHELF(S) LOCATED R-5
Located in the right side compartment #5
PO00019935 - ADJUSTABLE SHELF(S) LOCATED REAR COMPARTMENT Located in the rear compartment
PO00019997 - 250#, FLOOR MOUNTED, ROLLOUT TRAY
Slide out floor mount compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2" upward bend at front and rear, and side supports attached to #250 rated slides. Slide out floor mount shelving shall have gas shocks to hold the tray in and out.
Slide out floor mount shelving shall be as indicated at each compartment description.
PO00020028 - ROLLOUT TRAY, LOCATED L-2
Located in the left side compartment #2
PO00020031 - ROLLOUT TRAY, LOCATED L-5
Located in the left side compartment #5
PO00020035 - ROLLOUT TRAY, LOCATED R-2
Located in the right side compartment #2
PO00020041 - 250# ROLLOUT TRAY, LOCATED REAR COMPARTMENT Located in the rear compartment
PO00009876 - TURTLE TILE MATERIAL ON ALL COMPARTMENT FLOORS Turtle Tile brand floor material shall be installed on all compartment floors.
The Turtle Tile shall be custom installed to provide full floor coverage.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 129 of 140 PO00009869 - FLOORING MATERIAL ON SHELF(S) OR TRAY(S)
Floor matting material shall be provided on the noted quantity of specified shelves or roll-out trays.
PO00009870 - FLOORING MATERIAL COLOR (BLACK IS DEFAULT) The compartment flooring color shall be black.
***SPECIAL: SP00008663 - TOOL BOARDS ON REAR WALLS OF COMPARTMENTS 1/4" smooth aluminum tool boards shall be provided on the rear walls for mounting of loose equipment in the specified compartment. The tool boards will be as wide, wall to wall and as tall, floor to ceiling as possible.
The tool boards shall be located in the following compartment/s:
• Driver side upper front
• Driver side upper rear
PO00010847 - GENERAL PAINT DESCRIPTION
The apparatus body shall be painted with Sikkens paint product. The paint process shall meet or exceed current state regulations concerning paint operations. Pollution control shall include measures to protect the atmosphere, water, and soil. Contractor shall, upon demand, provide evidence that the manufacturing facility is in compliance with State EPA rules and regulations.
The exterior shall have no mounted components prior to painting to assure full coverage of metal treatments and paint to the exterior surfaces of the body. Any vertically or horizontally hinged smooth-plate compartment doors shall be painted separately to assure proper paint coverage on body, door jambs and door edges.
Paint process shall feature Sikkens high solid LV products and be performed in the following steps:
• Corrosion Prevention - all aluminum surfaces shall be pre-treated with the Alodine 5700 conversion coating to provide superior corrosion resistance and excellent adhesion of the base coat. • Sikkens Sealer/Primer LV - acrylic urethane sealer/primer shall be applied to guarantee excellent gloss hold-out, chip resistance and a uniform base color.
• Sikkens High Solid LVBT650 (Base coat) - a lead-free, chromate-free high solid acrylic urethane base coat shall be applied, providing excellent coverage and durability. A minimum of two (2) coats shall be applied. • Sikkens High Solid LVBT650 (Clear coat) - high solid LV clear coat shall be applied as the final step in order to ensure full gloss and color retention and durability. A minimum of two (2) coats shall be applied.
Any location where the material is penetrated after painting, for the purpose of mounting steps, hand rails, doors, lights, or other specified components shall be treated at the point of penetration with a corrosion inhibiting pre-treatment (ECK Corrosion Control). The pre-treatment shall be applied to the aluminum sheet metal or aluminum extrusions in all locations where the aluminum has been penetrated. All hardware used in mounting steps, hand rails, doors, lights, or other specified components shall be individually treated with the corrosion inhibiting pre-treatment.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 130 of 140 After the paint process is complete, the gloss rating of the unit shall be tested with a 20 degree gloss meter.
Coating thickness shall be measured with a digital MIL gauge and the orange peel with a digital wave scan device.
PO00010848 - GENERAL PRIMER & PREP DESCRIPTION - PUMPER All exposed welds shall be ground smooth for final finishing of areas to be painted.
The compartments and doors are totally degreased and phosphatized.
After final body work is completed, grinding (36 and 80 grit), and finish sanding shall be used in preparation for priming.
PO00010849 - GENERAL FINISH PAINT DESCRIPTION
The body shall be finish sanded and prepared for final paint.
Upon completion of final preparation, the body shall be painted utilizing the highest quality, state of the art, low V.O.C., polyurethane base paint.
Finish paint shall be applied in multiple coats to ensure proper paint coverage with a high gloss finish.
PO00010852 - CUSTOM FINISH PAINT & PREP
The applicable areas of the cab shall be finish sanded and prepared for final paint.
Upon completion of final preparation, the cab shall be painted utilizing the highest quality, state of the art, low V.O.C., polyurethane base paint.
Finish paint shall be applied in multiple coats to ensure proper paint coverage with a high gloss finish.
PO00010851 - CUSTOM CAB PRIMER & PREP
The cab primer shall be a two (2) stage process.
First stage shall be a coating with a two-part component, self-etching, and corrosion resistant primer to chemically bond the surface of the metal for increased adhesion.
Second stage shall be multiple coats of a catalyzed, two component, polyurethane primer applied for leveling of small imperfections and topcoat sealing.
PO00011730 - CUSTOM CAB UNDERSIDE PAINT - JOB COLOR
The exposed areas under the cab shall be painted job color to match the exterior cab.
On two tone cabs, this shall match the primary color.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 131 of 140 PO00023873 - CUSTOM CAB EXTENSION PAINT
PO00010853 - CUSTOM CAB BUFFING & FINISH
The exposed exterior finish of the cab shall be buffed and detailed.
PO00004569 - CUSTOM CAB INTERIOR PAINT - TEXTURED GRAY
The exposed interior metal surfaces of the cab shall be finish painted with a textured gray paint.
PO00010850 - BODY BUFFING & FINISH - PUMPER
The visible and exposed areas of the body shall be buffed and detailed.
PO00004547 - INSIDE/UNDERSIDE BODY PAINTED JOB COLOR - PUMPER The inside and underside of the complete body assembly shall be painted job color using a Sikkens paint system, prior to installation of the body on the chassis or torque box.
PO00004548 - JOB COLOR COMPARTMENT INT W/SPATTER PAINT - PUMPER/TANKER The interior of the compartments shall be finish painted job color with a scuff resistant webbing type paint of a contrasting color applied over the painted surfaces.
***SPECIAL: SP00032528 - FENDER COMPARTMENT INTERIOR-BLACK SPEEDY LINER The interior of the fender storage compartments including the cylinder/equipment shelves/brackets shall be finish painted with Black Speedy Liner paint to provide a protective finish.
PO00004566 - SINGLE COLOR CUSTOM CAB PAINT SCHEME - RED FLNA 3225 (E-1 RED) The cab exterior shall be finish painted with Sikkens paint system, single color, to match purchaser's furnished paint code.
PO00004558 - PUMPHOUSE & PLUMBING PAINTED JOB COLOR - PUMPER The pump enclosure and pump/plumbing within the pump enclosure shall be painted job color to match the primary color of the body.
PO00004555 - SINGLE COLOR BODY PAINT SCHEME - PUMPER - RED FLNA 3225 (E-1 RED) The body paint finish shall be Sikkens paint system in a single color to match customer furnished paint codes and requirements.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 132 of 140 PO00010855 - PINT OF TOUCH-UP PAINT
One (1) pint of each exterior color paint for touch-up purposes shall be supplied when the apparatus is delivered to the end user.
PO00010854 - FINALIZATION & DETAILING - PUMPER
Prior to delivery the vehicle, the interior and exterior be cleaned and detailed.
The finalization process detailing shall include installation of NFPA required labels, checking fluid levels, sealing and caulking required areas of the cab and body, rust proofing, paint touch-up, etc PO00004577 - CUSTOM CHASSIS JOB COLOR FRAME RAILS
The chassis frame rails, suspension, axles, and drivelines (with the exception of any PTO drivelines which shall be safety yellow) shall be painted with polyurethane paint to match the body color code prior to the installation of any air lines or electrical system to ensure serviceability.
PO00004588 - CUSTOM LETTERING ON FRONT CAB DOORS
Lettering provided on the driver's and officer's cab doors shall be custom height per Fire Department and engineering design.
PO00004583 - GOLDLEAF W/ DROP SHADOW LETTERING ON FRONT CAB DOORS Gold leaf, "Real Gold" vinyl, with drop shadow lettering shall be provided on the cab driver's and officer's doors per the fire department requirements.
The design of the lettering on the cab doors shall be designed to fit in the 496 sq. inches available.
PO00023730 - FRONT CAB DOOR TEXT LINE 1 - CITY OF HEMET PO00023731 - FRONT CAB DOOR TEXT LINE 2 - FIRE DEPARTMENT PO00004681 - FRONT CAB DOOR LETTERING TOP LINE ARCED
PO00004610 - CUSTOM LETTERING ON REAR CAB DOOR
Lettering provided on the front of cab shall be custom height per Fire Department and engineering design.
PO00009617 - GOLDLEAF W/ DROP SHADOW LETTERING ON REAR CAB DOORS Gold leaf, "Real Gold" vinyl, with drop shadow lettering shall be provided on the cab driver's and officer's doors per the fire department requirements.
The design of the lettering on the cab doors shall be designed to fit in the 496 sq. inches available.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 133 of 140 PO00023732 - REAR CAB DOOR TEXT LINE 1 - #
PO00023733 - REAR CAB DOOR TEXT LINE 2 - PARAMEDIC
PO00009624 - CUSTOM LETTERING ON FRONT OF CAB
Lettering provided on the front of cab shall be custom height per Fire Department and engineering design.
PO00004605 - GOLDLEAF W/ DROP SHADOW LETTERING ON FRONT OF CAB Gold leaf, "Real Gold" vinyl, with drop shadow lettering shall be provided on the front of the cab per the fire department requirements.
The design of the lettering on the front of the cab shall be designed to fit in the 167 sq. inches available.
PO00023734 - FRONT OF CAB TEXT - HEMET
PO00004625 - SCOTCH-LITE W/ DROP SHADOW LETTERING ON REAR BODY PANEL Scotch-Lite with drop shadow lettering shall be provided on the rear body panel per the fire department requirements.
The design of the lettering on the rear of the body shall be designed to fit in the 167 sq. inches available.
PO00023737 - REAR BODY TEXT LINE 1 - HMT
PO00023738 - REAR BODY TEXT LINE 2 - #
PO00023739 - REAR BODY TEXT LINE 3 - DATA ERROR
PO00004632 - CUSTOM LETTERING ON REAR BODY
Lettering provided on the rear body panel shall be custom height per Fire Department and engineering design.
PO00004635 - SCOTCH-LITE W/O DROP SHADOW LETTERING ON CAB ROOF Scotch-Lite without drop shadow lettering shall be provided on the cab roof per the fire department requirements.
The design of the lettering on the cab roof shall be designed to fit in the 2500 sq. inches available.
PO00004644 - 30" LETTERING ON CAB ROOF
Lettering provided on the cab roof shall be 30" high per Fire Department and engineering design.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 134 of 140 PO00023740 - CAB ROOF TEXT LINE 1 - HMT #
PO00023741 - CAB ROOF TEXT LINE 2 - DATA ERROR
PO00011791 - 6" SCOTCH-LITE STRIPE ON CAB AND BODY - PUMPER/TANKER A six (6) inch high "Scotch-Lite" stripe shall be provided.
The stripe shall be applied on a minimum of 60 percent of each side of the unit, 60 percent on the rear of the unit and 40 percent on the front of the unit.
The Scotch-Lite stripe layout shall be determined by the Fire Department.
PO00009526 - BLACK SCOTCH-LITE
The Scotch-Lite shall be black in color.
PO00009496 - 6" SCOTCH-LITE "Z" IN STRIPE
A six (6) inch simple "Z" effect shall be incorporated into the Scotch-Lite scheme on the body.
Final layout of this configuration shall be determined by the Fire Department. ***SPECIAL: SP00037912 - REAR CHEVRON PINSTRIPING
1/4" black vinyl pinstripes shall be provided on the front bumper chevron and rear chevron and shall overlap the chevron seams where the two colors meet. Clear tape shall be applied over the pinstriping.
PO00009536 - REAR CHEVRON STRIPING
REAR CHEVRON STRIPING
PO00012448 - ENTIRE REAR
The entire rear of the truck shall be covered with alternating strips of reflective striping.
PO00009540 - 6" FULL REAR ORALITE CHEVRON STRIPING
The striping shall be 6" Oralite reflective striping.
PO00024628 - RED & YELLOW ORALITE V98
The Oralite V98 reflective tape shall be #12 red and #18 yellow in color.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 135 of 140 PO00026066 - MISCELLANEOUS EQUIPMENT
The following equipment shall be mounted as specified or as loose equipment provided with the completed apparatus at the time of delivery:
PO00011822 - ROAD SAFETY KITS
A road safety kit shall be furnished with the following equipment:
• 2 1/2 lb. B-C fire extinguisher
• Triangle safety reflectors.
PO00009970 - ZICO SCBA CYLINDER BRACKET, MOUNTED AS DIRECTED A Zico SCBA bottle brackets mounted as directed by the fire department.
PO00000518 - TWO (2) ZICO #SAC-44 FOLDING WHEEL CHOCKS - FD MOUNTING Two (2) Zico model #SAC-44 folding wheel chocks shall be provided and mounted as directed by the fire department.
PO00023664 - KME WARRANTY, STARTING ON IN-SERVICE DATE
Warranty coverage by KME will begin when the customer places the unit in service. This date may not exceed 60 days from the date of delivery to the customer.
The Customer must email [email protected] within 60 days of delivery, or the warranty start date will default to the original delivery date.
PO00022810 - 1 YEAR WARRANTY - BASE WITH CUSTOM CHASSIS The proposed vehicle includes a one (1) year new vehicle warranty, upon delivery and acceptance of the vehicle.
The warranty will ensure that the vehicle has been manufactured to the proposed contract specifications and will be free from defects in material and workmanship that may appear under normal use and service within the warranty period. The warranty may be subject to different time and mileage limitations for specific components and parts. This warranty is issued to the original purchaser of the vehicle.
The warranty will not apply to tires, batteries, or other parts or components that are warranted directly by their manufacturers. The warranty will not apply to routine maintenance requirements as described in the service and operators manual. No warranty whether express, implied, statutory or otherwise including, but not limited to any warranty of merchantability or fitness for purpose will be imposed.
All components and parts of the vehicle are warranted for a period of one (1) year from acceptance of the vehicle unless excluded elsewhere in this warranty or described as having longer time limitations.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 136 of 140 PO00022661 - 5 YEAR CUMMINS BASE WARRANTY
The proposed unit will be equipped with a Fire Service rated engine, which will come furnished with a five (5) year Engine Manufacturer's warranty. A copy of the manufacturer's warranty will be supplied to define additional details of the warranty provisions.
PO00022665 - 5 YEAR ALLISON EVS TRANSMISSION WARRANTY
The proposed Allison transmission will be provided with a five (5) year warranty. A copy of the Allison transmission warranty will be supplied to the purchaser to define additional details of the warranty provisions.
PO00022980 - 3 YEAR COOLING SYSTEM WARRANTY - CUSTOM
Kovatch Mobile Equipment (KME) warrants all Cooling System Equipment components used in the construction of KME Fire Apparatus against defects and workmanship provided the apparatus is used in a normal and reasonable manner. This warranty is extended only to the original user-purchaser for a period of three (3) years from the date of delivery/acceptance to the original user-purchaser, whichever occurs first.
This warranty applies to both purchased and fabricated, manufacturer supplied coolant system components and is not provided in lieu of any Vendor provided warranties. All coolant system components provided by the engine manufacturer are covered by the engine manufacturer’s warranty only.
PO00022669 - LIFETIME FRAMERAIL WARRANTY
The proposed KME custom chassis frame and cross members will be warranted to the original purchaser for the life of the vehicle. A copy of KME's frame rail warranty will be supplied to define additional details of the warranty provisions.
PO00022978 - SHEPPARD STEERING GEAR STANDARD - THREE YEAR WARRANTY The proposed Sheppard steering gear will be warranted for a period of three (3) years from the first date of service or 150,000 miles (241,401 kilometers), whichever occurs first. The product will be free from defects in material and workmanship under normal use in applications approved in advance by Sheppard.
PO00022956 - 5 YEAR MERITOR 160 SERIES TANDEM AXLE REAR - WARRANTY The Meritor axle/s shall be provided with a five (5) year warranty. The first two (2) years shall be parts and labor; the remaining three (3) years shall be parts only. Wheel seals, gaskets and wheel bearings shall be covered for one year. A copy of Meritor's warranty shall be supplied to define additional details of the warranty provisions. Vehicles that operate full or part-time outside the United States and Canada shall have a one (1) year, parts only warranty.
PO00022681 - 3 YEAR MERITOR ABS - WARRANTY
The Meritor ABS shall be provided with a three (3) year warranty, parts and labor. A copy of Meritor's warranty shall be supplied to define additional details of the warranty provisions. Vehicles that operate full or part-time outside the United States and Canada shall have a one (1) year, parts only warranty.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 137 of 140 PO00022979 - 10 YEAR CAB STRUCTURAL WARRANTY
The proposed cab will be warranted against structural defects for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.
PO00022695 - 10 YEAR BODY STRUCTURAL WARRANTY
The proposed body will be warranted against structural defects for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.
PO00022698 - 10 YEAR CAB & BODY CORROSION WARRANTY
The cab and body shall be warranted against rust-through or perforation, due to corrosion from within, for a period of ten (10) years. Perforation is defined as a condition in which an actual hole occurs in a sheet metal panel due to rust or corrosion from within. Surface rust or corrosion caused by chips or scratches in the paint is not covered by this warranty.
PO00022701 - PAINT FINISH WARRANTY, TEN (10) YEAR
The proposed paint finish will be warranted for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.
PO00022702 - 5 YEAR LETTERING WARRANTY
The apparatus manufacturer will provide a five (5) year warranty against defects in material and workmanship for all graphics processes. Any valid claims must be made in writing within 15 days of the determination of any defects to the manufacturer's fire apparatus. The manufacturer will at its option make any necessary repairs either at a local authorized service center or at the factory if required. The manufacturer will make the final decision as to where the repairs are to be made and any transportation cost is the owner's responsibility. The manufacturer will at its option, repair or replace any verified defects in workmanship or materials at no cost to the owner provided all the requirements of this warranty have been met.
The manufacturer will not be liable to the original purchaser or anyone else for consequential, incidental, special or direct damages, including, but not limited to, any claims for loss of profits, downtime, loss of use or inconvenience. THE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OF IMPLIED, AND SPECIFICALLY, DISCLAIMS ANY IMPLIED WARRANTY INCLUDING THE WARRANTY OF MERCHANTABILITY.
The manufacturer continually strives to improve its products and therefore, reserves the right to make improvements or changes without incurring any obligations to make such changes or additions to equipment previously sold.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 138 of 140 PO00022703 - 1 YEAR BRIGHTWORK WARRANTY
KME Fire Apparatus (KME) warrants all bright finish components used in the construction of KME Fire Apparatus against defects and workmanship provided the apparatus is used in a normal and reasonable manner. This warranty is extended only to the original user-purchaser for a period of one (1) year from the date of delivery/acceptance to the original user-purchaser, whichever occurs first.
The expressed warranty excludes corrosion or degradation of bright finished components caused by damage to the component.
PO00022981 - 10 YEAR STAINLESS-STEEL PIPING WARRANTY
The proposed stainless-steel plumbing will be warranted for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.
PO00024719 - FRONT SUSPENSION - HENDRICKSON STEERTEK - 5 YEAR WARRANTY The Hendrickson Steertek NXT front axle shall be provided with a five (5) year parts and labor warranty and shall include the axle and kingpin assembly, the steering arm assembly, and the upper and lower steering knuckle assembly.
The warranty for the integrated suspension components shall be two (2) years or two hundred fifty thousand (250,000) miles, whichever occurs first.
The integrated suspension components covered under this two year warranty are limited to:
• Front Frame Hanger Assemblies
• Rear Shackle Assemblies
• Jounce Stop Assemblies
• Rear Frame Hanger Assemblies
• Shock Absorbers
• Shock Absorber Brackets
• Leaf Spring Assemblies
A copy of the Hendrickson Steertek NXT Warranty shall be provided to define additional details of the warranty provisions.
PO00023672 - REAR SUSPENSION - HENDRICKSON AIR RIDE - SINGLE AXLE -THREE YEAR WARRANTY Hendrickson warrants suspension products manufactured by it to be free from defects in material and workmanship which occur under normal use and service for a period of three(3) years (base year + 2 years).
This warranty will not apply and no warranty of any kind will exist as to any product which has been subject to abuse, misuse, neglect, misapplication or accident of any type or cause or which has been repaired, replaced, substituted or used with parts other than genuine Hendrickson parts or altered by anyone.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 139 of 140 PO00022973 - LIFETIME POLY TANK WARRANTY - ALL TANKS
The proposed water tank will be warranted by the water tank manufacturer for the "Lifetime" of the unit. A copy of the manufacturer's warranty will be supplied to define additional details of the warranty provisions.
PO00022734 - HALE FIRE PUMP LIMITED STANDARD WARRANTY
Hale Products, Incorporated ("Hale") hereby warrants to the original buyer that products manufactured by Hale shall be free of defects in material and workmanship for a period of five (5) years from the date product is first placed into service or five and one-half (5 1/2) years from date of shipment by Hale, whichever period shall be first to expire. Within this warranty period, Hale will cover parts and labor for the first two (2) years and parts only for years three (3) through five (5).
PO00022959 - FOAM PRO 2000 SERIES- FOAM SYSTEM - STANDARD WARRANTY The liability of FoamPro under the foregoing warranty will be limited to the repair or replacement at FoamPro’s option without charge for labor or materials of any parts upon return of the entire pump, system or other product or of the particular part to the FoamPro factory within the warranty period, at the sole expense of the purchaser, which part will upon examination appear to FoamPro’s satisfaction to have been defective in material and workmanship.
PO00022989 - CLASS 1 - PRODUCT WARRANTY
Class 1 warrants that any equipment of our own manufacture (or manufactured for us pursuant to our specifications) found to have defects in material or workmanship during normal use and service, will be repaired or replaced (at our opinion) free of charge, provided that written notice of such defect is received by us within two (2) years, (three 3 years on liquid filled gauges) after initial shipment.
PO00022760 - AKRON - 5 YEAR LIMITED WARRANTY
The limited warranty set forth here against defective materials or workmanship for a period of five (5) years will be given by Akron Brass Co. with respect to Akron Brass Co. products purchased and used in the United States and Canada respectively. All Akron valves are warranted for 10 years.
PO00022988 - AKRON - 5 YEAR LIMITED WARRANTY
The limited warranty set forth here against defective materials or workmanship for a period of five (5) years will be given by Akron Brass Co. with respect to Akron Brass Co. products purchased and used in the United States and Canada respectively. All Akron valves are warranted for 10 years.
PO00022983 - CLASS 1 - ELECTRICAL PRODUCT WARRANTY - 2 YEAR Class 1 warrants that any equipment of our own manufacture (or manufactured for us pursuant to our specifications) found to have defects in material or workmanship during normal use and service, will be repaired or replaced (at our option) free of charge, provided that written notice of such defect is received by us within two years (three for liquid-filled gauges) after initial shipment.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 140 of 140 All equipment requiring repair or replacement under this warranty will be returned prepaid to Class 1. Such returned equipment will be examined by us and, if found to be defective as a result of materials failure or workmanship, will be repaired or replaced at no charge.
PO00022985 - BOSTROM SEATING 5 YEAR LIMITED WARRANTY
H.O. Bostrom will warrant each new seat manufactured, to be free from defects in materials and workmanship when delivered to the original purchaser for a period of five (5) years.
Labor to remove or reinstall and transportation of defective items will not be covered by, or any allowance made for the said cost under this warranty.
PO00010937 - CORROSION TREATMENT
Upon apparatus completion, underside of the apparatus, from the pump enclosure-back, shall have anti corrosion film applied to help inhibit rust and the corrosion process. The semi-firm wax film shall be applied by air spray method. The film shall be applied as a minimum to the following areas: body substructure, underside of all body compartments, running board supports and rear step supports. No film shall be applied directly to the exhaust system or wheel wells.
NOTE: The film shall remain semi-firm to promote self-sealing. The film may leave a light tinted color to those areas treated.
PO00024906 - ADDITIONAL ITEMS SHIPPED WITH VEHICLE
• 1 - Pint of touch up paint for each color
• 1 - Bag of assorted stainless-steel nuts and bolts
16.H
TBD
C
A
B: 10
0"W
K
ME SEVERE SER
VICE LFD 10" R
R
ALU
M
EN
GINE &
TRA
NS: C
U
M
MINS X12 50
0 HP/ALLISO
N
4 0
0 0 EVS
A
XLES: 22,0
0 0
# STEERTEK FRO
N
T/24,0
0 0
# REAR
PU
MP: H
ALE Q
M
A
X-150 150
0 GPM SIN
GLE ST
A
GE/C
BP-250
W
A
TER
T
A
N
K: 50
0 G
ALLO
NS POLY
W/ 30/10
G
ALLO
N FO
A
M
B
O
D
Y
T
YPE: 143" FLA
T
B
A
C
K 12 G
A
G
ALV
FO
A
M SYSTEM: FO
A
M PR
O 20
01
16.H
16.H
DATE:
BY:
GSO:
CUSTOMER - DEALER:
BODY STYLE:
CHASSIS MAKE & MODEL:
WHEELBASE: 207
NUMBER OF PERSONNEL: 5
FRONT GVWR: 22000
REAR GVWR: 24000
TOTAL GVWR: 46000
ITEM DESCRIPTION ITEM
DETAILS
ITEM
WEIGHT
INCHES
FORWARD OF
REAR AXLE
WEIGHT ON
FRONT AXLE
WEIGHT ON
REAR AXLE
CHASSIS WEIGHT: 21384 16009 5375
PERSONNEL (DRIVER/OFFICER): 2 500 229 553 -53
PERSONNEL (CREW REAR FACING): 0 0 0
PERSONNEL (CREW FORWARD FACING): 3 750 156 565 185
BUMPER EXTENSION: 125 289 175 -50
BUMPER STORAGE WELL: 2 250 289 349 -99
CAB EMS CABINET: 2 200 202 195 5
PUMP WEIGHT: 1900 86 789 1111
CROSSLAYS: 3 600 121 351 249
SPEEDLAYS: 0 0 0
DECK GUN: 1 80 76 29 51
FRONT SUCTION: 207 0 0
REAR SUCTION: 0 0 0
FRONT DISCHARGES: 1 75 207 75 0
REAR DISCHARGES: 1 100 0 0 100
PTO PUMP: 1 2350 86 976 1374
REAR DIRECT TANK FILL: 0 0
HOSE REEL (INCLUDES HOSE): 1 250 76 92 158
WATER TANK (LOWER): 500 4450 7 150 4300
WATER TANK (UPPER): 0 0 0 0
FOAM TANK: 40 408 38 75 333
BODY WEIGHT: 4000 -12 -232 4232
EQUIPMENT ALLOWANCE: 2000 -12 -116 2116
LOCKER COMPARTMENT: 1 250 98 118 132
REAR STEP COMPARTMENT: 150 -62 -45 195
SCBA CYLINDER COMPT.: 6 180 0 0 180
HOSEBED (GENERAL): 1250 -24 -145 1395
HOSEBED (5"): 0 0 0
HOSEBED (4"): 0 0 0
HOSEBED (3"): 0 0 0
Original Issue Date: 12/20/2011
Revision: 3
Revision Date: 05/17/2018
Department: Sales Engineering
P73-1-F5
Weight Analysis Form
12/6/2021
JJM
QUOTE 7365-0
HEMET FD CA
147" FLAT BACK 12 GA GALV
100"W KME SEVERE SERVICE LFD 10" RR ALUM
Printed on: 12/8/2021 Page 1 of 2
16.H
DATE:
BY:
GSO:
CUSTOMER - DEALER:
BODY STYLE:
CHASSIS MAKE & MODEL:
WHEELBASE: 207
NUMBER OF PERSONNEL: 5
FRONT GVWR: 22000
REAR GVWR: 24000
TOTAL GVWR: 46000
ITEM DESCRIPTION ITEM
DETAILS
ITEM
WEIGHT
INCHES
FORWARD OF
REAR AXLE
WEIGHT ON
FRONT AXLE
WEIGHT ON
REAR AXLE
Original Issue Date: 12/20/2011
Revision: 3
Revision Date: 05/17/2018
Department: Sales Engineering
P73-1-F5
Weight Analysis Form
12/6/2021
JJM
QUOTE 7365-0
HEMET FD CA
147" FLAT BACK 12 GA GALV
100"W KME SEVERE SERVICE LFD 10" RR ALUM
HOSEBED (2.5"): 0 0 0
HOSEBED (1.75"): 0 0 0
HARD SUCTION HOSES: 0 0
LADDERS: 130 -7 -4 134
GENERATOR: 0 0
LIGHTING: 50 137 33 17
SIDE DUMPS: 0 0
REAR DUMP: 0 0
PORTABLE WATER TANK: 0 0
Q2B: 33 289 46 -13
HOSE BED COVER: 200 -24 -23 223
REAR STEP EXTENDED: 35 -85 -14 49
LADDER RACK: 200 -7 -7 207
0 0
0 0
0 0
0 0
0 0
TOTAL FRONT AXLE REAR AXLE
SUB-TOTAL: 41900 19995 21905
2% SAFETY FACTOR (GVWR): 838 400 438
TOTAL: 42738 20395 22343
CHASSIS GVWR: 46000 22000 24000
WEIGHT DIFFERENCE: 3262 1605 1657
WEIGHT DISTRIBUTION (%): 48% 52%
Printed on: 12/8/2021 Page 2 of 2
16.H
DATE:
BY:
GSO:
CUSTOMER - DEALER:
BODY STYLE:
CHASSIS MAKE & MODEL:
OVERALL HEIGHT:
REAR AXLE TRACK WIDTH: 72.79 Max CG Height: 58.232
OUTER REAR TIRE TO TIRE MEASUREMENT: Calculated CG: 50.48 (Assuming 24" to ground for Rear Step)
ITEM DESCRIPTION
ITEM
WEIGHT
(Wi)
INCHES
ABOVE
GROUND (yi)
W i* yi
CHASSIS CG: 21384 41 876744
PERSONNEL CG: 1250 71 88750
BUMPER EXT: 125 31 3875
PUMP (Only use if Commercial Chass.): 0
X-lay/SPEEDLAY: 600 85 51000
FRONT SUCTION: 0
REAR SUCTION: 0
FRONT DISCHARGE: 150 31 4650
DECK GUN: 80 93 7440
HOSE REEL(with hose): 250 85 21250
GENERATOR: 0
BODY CG: 4000 66 264000
EQUIPMENT CG: 2000 56 112000
WATER TANK CG: 4450 59 262550
FOAM TANK CG: 408 59 24072
HOSE LOAD CG: 1250 82 102500
HOSE BED FLOOR CG: 176 72 12672
LADDER CG: 130 108 14040
HOSE BED COVER CG: 160 100 16000
Q2B CG: 33 31 1023
SCBA CYLINDERS CG: 180 48 8640
PTO PUMP: 2350 41 96350
CALCULATED CG: 50.48
Department: Sales Engineering
P73-1-F8
Vertical CG Analysis Form
Original Issue Date: 12/20/2011
Revision: 0
Revision Date: 12/20/2011
147 FLAT BACK 12 GA GALV
100"W KME SEVERE SERVICE LFD 10" RR ALUM
12/06/21
JJM
QUOTE 7365-0
HEMET FD CA
116
Printed on: 12/8/2021 Page 1 of 1
16.H
KME Fire Apparatus
72 3
-69
0 Specified Hoseload Hoseload #1 Hoseload #2 Hoseload #3 Hoseload #4 Hoseload #5 Location:
Size: 2.5 4 2.5 1.75 1.75
Amount: 150 700 900 200 200
Storage Width: 6 28 25 5 5
Storage Height: 18 18 19 20 20
Storage Length: 102 102 102 102 102
Hose Width: 5 7 5 3.25 3.25
Hose Thickness: 0.75 0.75 0.75 0.69 0.69
Practical Hoselaod: 184 734 956 214 214
Specified Hoseload Hoseload #6 Hoseload #7 Hoseload #8 Hoseload #9 Hoseload #10 Location:
Size:
Amount:
Storage Width:
Storage Height: 8
Storage Length: 92
Hose Width: 0 0 0 0 0
Hose Thickness: 0 0 0 0 0
Practical Hoseload: #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! Split Bed Width (Uses Hoseload 6-10): Remaining Hosebed Space:
Original Issue Date: 12/20/2011
Revision: 1
Revision Date: 11/01/2013
Full Width Apparatus Hosebed Width: Remaining Hosebed Space:
QUOTE 7365-0
HEMET, CA
TBD
GSO:
Customer:
Sales Engineer:
Department: Sales Engineering
P73-1-F4
Hoseload Layout Guide
Split Bed Width (Uses Hoseload 1-5): Remaining Hosebed Space:
Created On: 12/8/2021
16.H
Battalion Chief Kevin Kuhlman
City of Hemet
445 East Florida Avenue
Hemet, CA 92543
Battalion Chief Kuhlman,
Qty
2 2
6 12
Thank you for the opportunity to present this proposal, and I look forward to working with you on this and future projects! Best Regards,
James Weber
Specialist Sales
[email protected]
(530) 414-6165 Cell
(570) 926-0611 Office
$6,400.00
$1,950.00 $11,700.00
KME Quotation Number QUO0000007365
This proposal superceeds any previous proposals(s) and/or offer(s) presented by KME Fire Apparatus and its employees or affiliates, and is valid for purchase until March 15, 2022. After this date, updated pricing will be required prior to an order being accepted by KME Fire Apparatus.
Delivery: 390 Days After Pre-Construction Meeting
California Tire Fee (Calculated at $1.75/Tire for 6 Tires Per Apparatus): $1.75 $21.00 Terms: Net 30 Days
FOB Hemet, CA
$128,451.75
Total Proposal Cost: $1,626,292.75
PROPOSAL PRICING
February 17, 2022
On behalf of KME Fire Apparatus, I am pleased to offer the following proposal for two (2) 2023 KME Type 1 Pumpers on Severe Service chassis per the attached specifications. This pricing is inclusive of applicable taxes and fees as detailed below, and includes three (3) factory trips for two (2) City of Hemet staff members.
The pricing is as follows:
2023 KME Type 1 Pumper:
California Sales Tax (Calculated at 8.75%):
Cost Each Cost Extended
$734,010.00 $1,468,020.00
Item
100% Performance Bond:
Factory Trips (3 inspection trips to manufacturer, 2 people per trip):
$3,200.00
www.kmefire.com
One Industrial Complex | Nesquehoning, PA 18240
T (800) 235-3928 | P (570) 669-9461
Member of the REV Group
16.H
Battalion Chief Kevin Kuhlman
City of Hemet
445 East Florida Avenue
Hemet, CA 92543
Battalion Chief Kuhlman,
We at KME look forward to serving you!
Best Regards,
James Weber
Specialist Sales
[email protected]
(530) 414-6165 Cell
(570) 926-0611 Office
KME Quotation Number QUO0000007365
These pre-payment discount options superceed any previous discount options presented by KME Fire Apparatus and its employees or affiliates, and are valid for use with your purchase until March 15, 2022. After this date, updated discount options will be required prior to acceptance by KME Fire Apparatus.
KME is also pleased to share that we have recently improved our prepayment discount structure, giving the City of Hemet more flexibility in how you pay for your investment, providing additional opportunities to free up your budget for equipment or upfits. 90% Contract Pre-Payment within 30 Days of Order
75% Contract Pre-Payment within 30 Days of Order
50% Contract Pre-Payment within 30 Days of Order
25% Contract Pre-Payment within 30 Days of Order
$1,463,663.48
$1,219,719.56
$813,146.38
$406,573.19
PRE-PAYMENT DISCOUNTS
February 17, 2022
On behalf of KME Fire Apparatus, I am pleased to offer the following prepayment discount options available in conjunction with the purchase of your 2023 KME Type 1 Pumpers.
The pre-payment discounts are will be based on the following schedule:
Pre-Payment Option
100% Contract Pre-Payment within 30 Days of Order
Pre-Payment Amount
(Per Contract)
$1,626,292.75
Pre-Payment Discount
(Per Unit)
$9,462.00
(Per Contract)
$18,924.00
$17,032.00
$14,193.00
$9,462.00
$37,848.00
$34,064.00
$28,386.00
$18,924.00
$4,731.00
www.kmefire.com
One Industrial Complex | Nesquehoning, PA 18240
T (800) 235-3928 | P (570) 669-9461
Member of the REV Group
16.H
Battalion Chief Kevin Kuhlman
City of Hemet
445 East Florida Avenue
Hemet, CA 92543
Battalion Chief Kuhlman,
Best Regards,
James Weber
Specialist Sales
[email protected]
(530) 414-6165 Cell
(570) 926-0611 Office
The option(s) and pricing presented above superceed any previous option offers presented by KME Fire Apparatus and its employees or affiliates, and are valid for use with your purchase until March 15, 2022. After this date, updated option pricing will be required prior to acceptance by KME Fire Apparatus.
KME Quotation Number QUO0000007365
-$15,000.00
Option Description
Additional Two (2) Year Extended Warranty
-$3,200.00
-$12,500.00
$5,700.00
$31,800.00
Delete $15,000 Contingency for Communications Installation Additional Five (5) Year Extended Warranty
Delete 100% Performance Bond
Delete Hale MBP PTO Driven Auxiliary Pump and Associated Plumbing
ORDER OPTIONS
February 17, 2022
On behalf of KME Fire Apparatus, I am pleased to offer the following factory options available in conjunction with the purchase of your 2023 KME Type 1 Pumpers.
These options are available at the following rates:
Option Cost (Per Unit)
www.kmefire.com
One Industrial Complex | Nesquehoning, PA 18240
T (800) 235-3928 | P (570) 669-9461
Member of the REV Group
16.H
MANUFACTURERS DETAILED SPECIFICATIONS
kmefire.com One Industrial Complex | Nesquehoning, PA 18240 T (800) 235-3928 | P (570) 669-9461
Member of the REV Group
City of Hemet
Quote # QUO0000007365 (Rev 0)
2023 Type 1 ‘Severe Service’ Pumper
February 17, 2022
Prepared For: Presented By:
City of Hemet KME – California
Kevin Kuhlman James Weber
Battalion Chief Specialist Sales
510 East Florida Avenue 4725 Troy Court
Hemet, CA 92543 Jurupa Valley, CA 92509
(951) 282-5531 (530) 414-6165
[email protected] [email protected]
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 2 of 140 PO00025823 - DESIGN CLAUSE
These specifications outline the components, installation methods, and operational characteristics KME is agreeing to provide in order to meet the purchaser’s requirements. Subject to the terms of the purchase agreement, other construction details not explicitly listed in these specifications will be determined at the discretion of the builder. In the event the purchaser desires a different construction or installation not already described in these specifications, additional charges may apply, and quoted lead time commitments will be adjusted.
PO00011025 - PROPOSED BY - KME FIRE APPARATUS - CALIFORNIA KME Fire Apparatus is pleased to offer the proposed vehicle to meet the intent of the fire department specifications.
KME Fire Apparatus is a leading manufacturer in custom and commercial fire fighting vehicles.
Questions or concerns pertaining to this proposal can be answered by contacting the following KME personnel:
KME Fire Apparatus
4725 Troy Ct.
Jurupa Valley, CA 91761
Phone: (800) 328-1033 / (909) 937-3326
Fax: (909) 937-1762
E-mail: [email protected]
PO00011181 - COMPLETION INFORMATION
The contractor shall supply, at the time of delivery, at least one (1) copy of the following documents. • Owners name and address Apparatus manufacturer, model and serial number • Chassis make, model and serial number
• Front tire size and total rated capacity in pounds
• Rear tire size and total rated capacity in pounds
• Chassis weight distribution in pounds with water and manufacturer mounted equipment, front and rear • Engine make, model, serial number, rated horsepower, rated speed and governed speed • Type of fuels and fuel tank capacity
• Electrical system voltage and alternator output in amps. • Battery make, model and total capacity in cold crank amps (CCA) • Transmission make, model, and serial number. If so equipped chassis transmission PTO(s) make, model and gear ratio
• Pump make, model, rated capacity in gallons per minute (liters per minute where applicable) and serial number
• Pump transmission make, model, serial number and gear ratio
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 3 of 140 • Auxiliary pump make, model, rated capacity in gallons per minute (liters per minute where applicable) and serial number
• Water tank certified capacity in gallons or liters
• Paint manufacturer and paint number(s)
• Company name and signature of responsible company representative • Certification of slip resistance of all stepping, standing and walking surfaces.
If the apparatus has a fire pump or an industrial supply pump, the pump manufacturer's certification of suction capability.
If the apparatus has a fire pump or an industrial supply pump, a copy of the apparatus manufacturer's approval for stationary pumping applications.
If the apparatus has a fire pump or an industrial supply pump, the engine manufacturers certified brake horsepower curve for the engine furnished, showing the maximum governed speed.
If the apparatus has a fire pump or an industrial supply pump, the pump manufacturers certification of hydrostatic test.
If the apparatus has a fire pump or an industrial supply pump, the third-party certification of inspection and test for the fire pump (if applicable).
If the apparatus has an aerial device the third-party certification of inspection and test for the aerial device.
If the apparatus has an aerial device, all the technical information required for inspections to comply with NFPA 1911, Standards for Testing Fire Department Aerial Devices.
If the apparatus has a fixed line voltage power source, the certification of the test for the fixed power source (if applicable).
If the apparatus is equipped with an air system, test results of the air quality, the SCBA fill station, and the air system installation.
Weight documents from certified scale - showing actual loading on the front axle, rear axle(s) and overall vehicle (with the water tank full but without personnel, equipment and hose) shall be supplied with the complete vehicle to determine compliance with NFPA-1901.
Written load analysis and results of electrical performance tests.
If the apparatus is equipped with a water tank, the certification of water tank capacity by the tank manufacturer.
PO00011182 - FMVSS REQUIREMENT
The chassis shall be certified by the apparatus manufacturer as conforming to all applicable Federal Motor Vehicle Safety Standards in effect at the date of contract.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 4 of 140 This shall be attested to by the attachment of a FMVSS certification label on the vehicle by the contractor who shall be recognized as the responsible final manufacturer.
PO00011183 - RECORDS
The successful bidder shall be responsible for preparing and maintaining a record file of parts and assemblies used to manufacture the apparatus.
These records shall be maintained in the factory of the bidder for a minimum of twenty (20) years.
File shall contain copies of any and all reported deficiencies, all replacement parts required to maintain the apparatus, and original purchase documents including specifications, contract, invoices, incomplete chassis certificates, quality control reports and final delivery acceptance documents.
The Hemet Fire Department shall have access to any and all documents contained in this file upon official written request.
PO00011186 - GENERAL CONSTRUCTION
The complete apparatus, assemblies, subassemblies, component parts, etc., shall be designed and constructed with the due consideration to the nature and distribution of the load to be sustained and to the general character of the service to which the apparatus is to be subject.
All parts of the apparatus shall be designed with a factor of safety, which is equal to or greater than that which is considered standard and acceptable for this class of equipment in firefighting service.
All parts of the apparatus shall be strong enough to withstand general service under full load.
The apparatus shall be so designed that the various parts and readily accessible for lubrication, inspection, adjustment and repair.
Bidder's specifications must meet minimum requirements of N.F.P.A. Pamphlet #1901 and all State and Federal Department of Transportation vehicle regulations at time of sale of unit.
The apparatus shall be designed and constructed, and the equipment so mounted, with due consideration to distribution of the load between front and rear axles that all specified equipment, including a full complement of specified ground ladders, full water tank, loose equipment, and firefighters shall be carried without overloading or injuring the apparatus.
PO00011188 - PRODUCT LIABILITY
Each bidder shall supply proof of product liability and facility insurance equal to or exceeding $30,000,000.00.
This shall be provided as part of the proposal. There will be no exceptions.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 5 of 140 PO00011192 - PAINT CERTIFICATION
The finish paint shall be certified by the apparatus manufacturer as conforming to all applicable Commercial Vehicle Paint Standards in effect at the date of contract.
This shall be attested to by the attachment of a Sikkens certification.
PO00011193 - PARTS & SERVICE DEPOT
The manufacturer shall have an authorized service center, with a staff of factory-trained mechanics, well versed in all aspects of service for all major components, of the apparatus within a 300-mile radius of the Purchaser.
In addition, the manufacturer shall maintain a separate service facility at the manufacturing site, in order to satisfy the need for possible major emergency service work.
PO00011194 - SERVICE SHOP DETAILS
The center must provide a full-time staff of experienced technicians with all of the required equipment to provide modern, accurate and efficient service.
Bidders shall state the size of their shop and officer area in square feet.
They shall state the location of the facility and provide photos of both the exterior and interior of the center.
Accuracy of the description of the service center is of great importance.
PO00023879 - PRICES & PAYMENTS
The bid price will be F.O.B. Destination, on a delivered and accepted basis at the Fire Department.
Total price on KME's proposal sheet will include all items listed in these specifications.
KME has computed pricing less federal and state taxes. It is understood that any applicable taxes will be added to the proposed prices, unless the purchaser furnishes appropriate tax-exempt forms.
PO00010973 - FAIR ETHICAL & LEGAL COMPETITION
In order to ensure fair, ethical, and legal competition, neither original equipment manufacturer (OEM) nor parent company of the OEM shall have ever been fined or convicted of price fixing, bid rigging, or collusion in any domestic or international fire apparatus market.
There will be no exceptions.
PO00010976 - MATERIAL & WORKMANSHIP
All equipment furnished shall be guaranteed to be new and of current manufacture, to meet all requirements of these specifications.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 6 of 140 All workmanship shall be of high quality and accomplished in a professional manner so as to insure a functional apparatus with a pleasing, aesthetic appearance.
PO00010978 - CONTRACT ADMINISTRATOR
The successful bidder shall designate a contract administrator to provide a single point interface between the purchaser and the contractor on all matters concerning the contract.
PO00010979 - APPROVAL DRAWING
A detailed drawing of the apparatus shall be provided to the purchaser for approval before construction begins. A copy of this drawing shall also be provided to the manufacturer's representative. Upon purchaser's approval, the finalized drawing shall become a part of the total contract.
The drawing shall show, but is not limited to, such items as the chassis make and model, major components, location of lights, sirens, all compartment locations and dimensions, special suctions, discharges, etc. The drawing shall be a visual interpretation of the apparatus as it is to be supplied.
PO00011122 - INSPECTION TRIPS (3)
The successful bidder shall provide three (3) factory inspection trips to the apparatus manufacturer's facility.
Transportation, meals, lodging, and other requisite expenses shall be the bidder's responsibility.
PO00011127 - ACCOMMODATIONS FOR TWO (2) FIRE DEPARTMENT PERSONNEL Accommodations shall be for two (2) Fire Department representatives per trip.
The factory visits shall occur at the following stages of production of the apparatus:
PO00011134 - TRIP ONE (1) AT PRE CONSTRUCTION
Pre-construction / blueprint review.
PO00011144 - TRIP TWO (2) AT MID-POINT COMPLETION
Midpoint completion of entire apparatus.
PO00011150 - TRIP THREE (3) AT FINAL COMPLETION
Final inspection upon completion.
PO00011163 - AIR TRANSPORTATION (1000 MILES OR MORE)
Travel arrangements more than 1000 miles from the manufacturing facility shall be via commercial airline transportation.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 7 of 140 The Hemet Fire Department maintains the right to inspect the apparatus, within normal business hours, at any other point during construction.
Expenses incurred during non-specified inspection visits shall be the responsibility of the Hemet Fire Department.
During inspection visits, the Hemet Fire Department reserves the right to conduct actual performance tests to evaluate completed portions of the unit.
Testing shall be accomplished with the assistance and resources of the contractor.
PO00010981 - DELIVERY
Delivery of the apparatus to the customer shall remain the bidder's responsibility.
On initial delivery of the fire apparatus, a qualified and responsible representative of the contractor shall demonstrate the apparatus and provide initial instruction to representatives of the customer regarding the operation, care, and maintenance of the apparatus and equipment supplied.
PO00025825 - INSTRUCTION MANUALS - TWO (2) SETS - USB
In accordance with standard commercial practices, applicable to each vehicle (including body and special equipment) furnished under the contract, the following listed manuals and schematics, in the quantity specified, shall be provided at time of delivery of each vehicle.
The contractor shall supply at time of delivery, two (2) USB copies of a complete operation and service manual covering the complete apparatus as delivered and accepted.
The manual shall contain the following:
• Descriptions, specifications, and ratings of chassis, pump (if applicable), and aerial device • Wiring diagrams
• Lubrication charts
• Operating instructions for the chassis, any major components such as a pump and any auxiliary systems • Instructions regarding the frequency and procedures recommended for maintenance • Parts replacement information
PO00011002 - PRODUCTION LEVEL ELECTRICAL DRAWINGS
KME shall provide production level harness drawings for the specific unit to be built.
PO00011003 - AS-BUILT PLUMBING SCHEMATICS
In accordance with standard commercial practices, the manufacturer shall supply two (2) copies of "AS BUILT" plumbing schematics/diagrams for the pumping system at the time of delivery.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 8 of 140 PO00010982 - VEHICLE FLUID PLATE
As required by NFPA-1901, the contractor shall affix a permanent plate in the driver's compartment specifying the quantity and type of the following fluids used in the vehicle:
A permanent plate in the driving compartment shall specify the quantity and type of the following fluids used in the vehicle:
• Engine oil
• Engine coolant
• Chassis transmission fluid
• Pump transmission lubrication fluid
• Pump primer fluid
• Drive axle(s) lubrication fluid
• Air-conditioning refrigerant
• Air-conditioning lubrication oil
• Power steering fluid
• Cab tilt mechanism
• Transfer case fluid
• Equipment rack fluid
• Air compressor system lubricant
• Generator system lubricant
• Aerial systems
PO00010983 - PRE-DELIVERY SERVICE
After transportation from the factory and immediately prior to delivery to the fire department, the apparatus shall receive a pre-delivery service consisting of: engine oil filter change, chassis lubrication, fuel filter(s) changed, adjustment of engine to manufacturers specifications, complete inspection including all electrical and mechanical devices, for proper operation and correction of leaks or obvious problems.
PO00010988 - EXACT BLUEPRINT WITH BID
A scale drawing of the specific apparatus being proposed shall be submitted WITH THE BID.
Drawings of similar units or demo units shall not be permitted.
Bidders should be clear that this provision is requiring a SCALE drawing of the truck which is actually being bid.
The drawing shall be done at the manufacturer's facility by the manufacturer's engineering department in order to guarantee the accuracy of the drawing.
Failure to comply with this requirement shall be grounds for rejection of the bid!
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 9 of 140 PO00010990 - FAMA MEMBERSHIP
The apparatus manufacturer must be a current member of the Fire Apparatus Manufacturer's Association (FAMA).
PO00010992 - MANUFACTURED IN UNITED STATES
The entire apparatus shall be assembled within the borders of the Continental United States to insure more readily available parts (without added costs and delays caused by tariffs and customs) and service.
PO00010993 - ISO REQUIREMENT
The manufacturer shall operate a Quality Management System that is certified to ISO 9001 by an organization that is accredited by the ANSI-ASQ National Accreditation Board (ANAB).
This type of business management system shall allow the manufacturer to monitor processes to ensure they are effective; keep adequate records; check output for defects, with appropriate and corrective action where necessary; regularly review individual processes and the quality system itself for effectiveness; and facilitate continual improvement.
A copy of the registration certificate must be included in the proposal, NO EXCEPTIONS.
PO00010997 - AMP DRAW REPORT
The bidder shall provide with their bid proposal and at the time of delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.
A written load analysis, which shall include the following:
• The rating of the alternator.
• The minimum continuous load of each component that is specified per: Applicable NFPA-1901. • Additional loads that, when added to the minimum continuous load, determine the total connected load. • Each individual intermittent load.
All of the above listed items shall be provided by the bidder per the applicable NFPA-1901.
PO00011001 - COOPERATIVE PURCHASING
The Manufacturer shall be pleased to allow other public agencies to use the purchase agreement resulting from this invitation to bid unless the bidder expressly notes on the proposal form that prices are not available for tag-on.
The condition of such use by other agencies shall be that any such agency must make and pursue contact, purchase order/contract, and all contractual remedies with the successful bidder.
Such tag-ons shall be done so that the original purchasing agency has no responsibility for performance by either the manufacturer or the agency using the contract.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 10 of 140 PO00011022 - VEHICLE DATA PLATE DESCRIPTION
The following safety signs shall be provided in the cab:
• A label displaying the maximum number of personnel the vehicle is designed to carry shall be visible to the driver.
• “Occupants will be seated and belted when apparatus is in motion” signs shall be visible from each seat. • “Do Not Move Apparatus When Light Is On” sign adjacent to the warning light indicating a hazard if the apparatus is moved (as described in subsequent section). • A label displaying the height, length, and GVWR of the vehicle shall be visible to driver. • This label shall indicate that the fire department will revise the dimension if vehicle height changes while vehicle is in service.
The following information shall be on labels affixed to the vehicle:
Fluid Data
• Engine Oil
• Engine Coolant
• Chassis Transmission Fluid
• Pump Transmission Lubrication Fluid
• Pump Primer Fluid (if applicable)
• Drive Axle(s) Lubrication Fluid
• Air Conditioning Refrigerant
• Air Conditioning Lubrication Oil
• Power Steering Fluid
• Cab Tilt Mechanism Fluid
• Transfer Case Fluid (if applicable)
• Equipment Rack Fluid (if applicable)
• Air Compressor System Lubricant
• Generator System Lubricant (if applicable)
• Front Tire Cold Pressure
• Rear Tire Cold Pressure
• Aerial Hydraulic Fluid (if applicable)
• Maximum Tire Speed Rating
Chassis Data
• Chassis Manufacturer
• Production Number
• Year Built
• Month Manufactured
• Vehicle Identification Number
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 11 of 140 Manufacturers weight certification:
• Gross Vehicle (or Combination) Weight Rating (GVWR or GCWR) • Gross Axle Weight Rating, Front
• Gross Axle Weight Rating, Rear
PO00025023 - VEHICLE TRANSPORTATION - KME PROVIDED (ZONE 5 CLASS 1) Transportation for the completed vehicle from KME Fire Apparatus in Nesquehoning, PA to the end user shall be provided by KME.
PO00009791 - !!! CRITICAL OVERALL HEIGHT REQUIREMENT !!! - "YES" - 10' 8" This vehicle has a critical overall height restriction requirement due to fire station door height or obstruction within the fire department/district.
Maximum overall height of vehicle in the unloaded configuration cannot exceed: 128" (inches).
PO00010995 - NFPA CERTIFICATION
The proposed apparatus will be constructed to withstand the severe and continuous use encountered during emergency firefighting services.
The apparatus will be of the latest type, carefully designed and constructed with due consideration to the nature and distribution of the load to be sustained.
This proposal details the general design criteria of cab and chassis components, aerial device (if applicable), fire pump and related components (if applicable), water tank (if applicable), fire body, electrical components, painting, and equipment.
All items of these proposal specifications will conform to the fullest extent possible with the National Fire Protection Association Pamphlet No. 1901, latest edition, except as noted in the Statement-of-Exceptions.
KME will furnish satisfactory evidence of our ability to construct, supply service parts and technical assistance for the apparatus specified.
PO00011070 - GENERAL INFORMATION - NFPA 1901
The proposed apparatus will be constructed to withstand the severe and continuous use encountered during emergency firefighting services. The apparatus will be of the latest type, carefully designed and constructed with due consideration to the nature and distribution of the load to be sustained.
This proposal details the general design criteria of cab and chassis components, aerial device (if applicable), fire pump and related components (if applicable), water tank (if applicable), fire body, electrical components, painting, and equipment.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 12 of 140 All items of these proposal specifications will conform to the fullest extent possible with the National Fire Protection Association Pamphlet No. 1901, latest edition, except as noted in the Statement-of-Exceptions.
KME will furnish satisfactory evidence of our ability to construct, supply service parts and technical assistance for the apparatus specified.
PO00026614 - NFPA TREAD PLATE STEPPING/STANDING/WALKING SURFACE CERTIFICATION All stepping, standing, and walking surfaces on the body shall meet NFPA #1901 anti-slip standards.
Aluminum tread plate utilized for stepping, standing, and walking surfaces shall be NFPA embossed compliant.
Upon request by the purchaser, the manufacturer shall supply proof of compliance with this requirement.
PO00026615 - VERTICAL TREAD PLATE - EMBOSSED
The vertical surfaces on the vehicle shall have embossed NFPA tread plate.
PO00009789 - "PUMPER FIRE APPARATUS" NFPA 2016 CHAPTERS OF COMPLIANCE The unit shall be designed to conform fully to the "Pumper Fire Apparatus" requirements as stated in the NFPA 1901 Standard (2016 Revision), which shall include the following required chapters as stated in this revision:
• Chapter 1 Administration
• Chapter 2 Referenced Publications
• Chapter 3 Definitions
• Chapter 4 General Requirements
• Chapter 5 Pumper Fire Apparatus
• Chapter 12 Chassis and Vehicle Components
• Chapter 13 Low Voltage Electrical Systems and Warning Devices • Chapter 14 Driving and Crew Areas
• Chapter 15 Body, Compartments and Equipment Mounting
• Chapter 16 Fire Pumps and Associated Equipment
• Chapter 18 Water Tanks
PO00011170 - NFPA "CHAPTER 17" {AUXILIARY PUMP} REQUIREMENT - 2016 Chapter 17 Auxiliary Pump and Associated Equipment
PO00011172 - NFPA "CHAPTER 20" {FOAM SYSTEM} REQUIREMENTS - 2016 Chapter 20 Foam Proportioning Systems
PO00010889 - SAFETY SIGNS (NFPA REQUIRED)
Safety sign(s) shall be located on the vehicle at the rear step, and at any cross walkway(s), to warn personnel that riding in or on these areas while the vehicle is in motion is prohibited.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 13 of 140 PO00025814 - THIRD PARTY TESTING
If required by the specific chapters of NFPA-1901, the proposed unit shall be tested and certified by independent third-party inspectors.
All test work for fire pumps outlined in NFPA 1901, Edition shall be conducted.
The third-party inspectors shall provide the manufacturer a complete written examination and test report for each inspection performed at the manufacturer's facility.
This report specifies the points of inspection and results of such examinations and tests.
The inspectors performing the test work on the units are certified to Level II in the required NDT methods, under the requirements outlined in ASNT document CP-189.
The actual person(s) performing the inspection shall present for review proof of Level II Certification in the required NDT methods.
The apparatus manufacturer shall designate, in writing, who is qualified to witness and certify these test results.
Prior to submittal to the automotive fire apparatus manufacturer, the final Report shall be reviewed by the Supervisor of Fire Equipment Services and a Registered Professional Engineer, both of whom are directly involved with the aerial device certification program.
When the unit successfully meets all the requirements outlined in NFPA 1901, current edition, the third-party inspector shall issue a Certificate of Automotive Fire Apparatus Examination and Test stating the unit's compliance with NFPA- 1901.
PO00025818 - FOAM SYSTEM TESTING
When the unit successfully meets all the requirements outlined in NFPA 1901, Latest Edition, third-party inspectors shall issue a Certificate of Automotive Fire Apparatus Examination and Test stating the unit's compliance with the required foam proportioning section of NFPA.
PO00025687 - SEVERE SERVICE CAB - BASE, 100" - S2020
The cab shall be a custom tilt style, built specifically for fire service.
The cab shall be a cab over engine design, with integral tilt mechanism and engine access from inside the cab.
The cab interior shall be the "Open-Space" design with no wall, window or vertical support posts between the front and rear crew areas to allow direct communication, better visibility and air circulation in the cab.
PO00001589 - PREDATOR CAB - BASE -ALUMINUM CONSTRUCTION The cab shall be fabricated from 5052-H 32 aluminum alloy, utilizing the minimum material thickness as follows:
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 14 of 140 • Cab side panels 0.125 thick (1/8")
• Cab roof 0.125 thick (1/8")
• Forward cab front sheet 0.125 thick (1/8")
• Interior cab panels 0.125 thick (1/8")
• Other panels 0.125 thick (1/8")
• Cab doors 0.1875 thick (3/16")
• Engine enclosure side panels 0.250 thick (1/4")
Cab, sub-frame shall be a welded assembly, fabricated of 6063 structural aluminum alloy. This frame shall extend the full length and width of the cab and be secured to the chassis frame through two (2) rear, urethane, self-centering load cushions, two (2) forward pivot brackets, and two (2) cab locks. The cab shall be of entirely welded construction.
The front cab wall shall be of double wall type construction, featuring an inner and outer panel. {No Exceptions} PO00010253 - SEVERE SERVICE 100" - CRASH TESTING
To ensure the safety of the cab occupants and cab integrity, proof of third-party testing shall be provided.
The cab shall be certified for SAEJ2422 side impact, SAEJ2420 with ECER29 cab front impact, and ECER29 cab roof strength.
Furthermore, proof of testing and certification shall be provided that the cab, in accordance with SAE J2420 was front impact tested at 2.1 times the standard energy required in SAE J2420, thus exceeding the NFPA requirement.
This test shall be performed with no support immediately behind the cab, thus providing an authentic test result.
PO00024135 - DIMENSIONS – LONG FOUR DOOR STYLE CAB - 100" Minimum Cab Dimensions:
• Overall width 100"
• Inside width of ceiling 92"
• Front area floor to ceiling 59-3/4"
• Top of front seat to ceiling 42" (depending upon seat type) • Seat back to steering wheel 21-1/4" (depending upon seat type) • Inside width (door to engine enclosure) 27-1/2" (driver's side, at the floor) • Inside width (door to engine enclosure) 24" (officer's side, at the floor) • Crew seat area width 92"
• Front cab floor to top of engine enclosure 27”
• Front cab floor to top of center dash 34-3/4”
• Outer crew seat risers to rear wall 49-1/2"
• Centerline axle to rear wall 67-1/2"
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 15 of 140 Glass Area Dimensions:
• Windshield (Contour) 3,422 sq. in.
• Side door window, retractable 625 sq. in. each
• Side fixed crew windows 550 sq. in. each
PO00026691 - 10" RAISED ROOF
Cab Entry Door Height Dimensions:
• Forward door opening 76" high
• Rear door opening 86" high
The roof will be a split level design with radius edges for an aesthetic, streamline appearance. The roof shall be constructed with the same material as the main structure and be internally reinforced using framing which shall span the entire width and length of the cab for maximum structural integrity. This shall allow the roof to support personnel and roof mounted equipment without the need for additional reinforcement. The cab roof over the rear crew area shall be raised ten (10) inches higher than the front driver and officer area. The front face of the raised roof section shall be sloped at a 45 degree angle, creating a streamlined interface with the standard, lower, forward roof section. This design shall allow for additional interior height in the rear crew area.
The rear crew area doors shall be "Vista-Style", extending full height to the radius edge of the raised roof.
Approximate dimensions:
• Crew area floor to ceiling 64"
• Top of crew seat to ceiling 45" (depending upon seat type) PO00024811 - CAB ROOF TREAD PLATE OVERLAY, BLACK
The specified cab roof walking surface overlay shall be covered in a black line-x (or equal) material.
PO00026121 - INTEGRAL CAB ROOF DRIP RAIL PREDATOR, PANTHER, SEVERE SERVICE For enhanced protection from inclement weather, an integral drip rail shall be furnished on each side of the cab roof. The drip rail shall extend the full length of the cab roof.
PO00010667 - CAST ANTI-SLIP ENTRY STEPS FOR REDUCED LENGTH DOOR The front entrance steps shall be a minimum of 9" deep.
Each step shall be a cast aluminum, open grate style step fabricated by Cast Products Inc. with a polished aluminum outer surface.
The cab step risers shall be overlaid with.063" tread plate.
The rear entrance steps shall be a minimum of 9" deep.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 16 of 140 Each step shall be a cast aluminum, open grate style step fabricated by Cast Products Inc. with a polished aluminum outer surface.
The cab step risers shall be overlaid with.063" tread plate.
PO00012134 - BATTERY ACCESS DOORS - REAR STEP WELLS, EACH SIDE The battery access door(s) shall be 1/8" tread plate, drop down doors with thumb latches at each side rear cab step well.
PO00001638 - BARRIER HEIGHT CAB DOORS, 100" PREDATOR SS "X-MFD, LFD & X-LFD" Four (4) side-opening doors shall be provided. The cab doors shall be shortened to the floorboard level thus leaving an exposed step well area at each cab entrance. The cab doors shall be totally constructed of aluminum with an extruded aluminum frame and an aluminum outer door skin. The forward cab door opening shall be a minimum of 37" wide and the rear cab door opening shall be a minimum of 37" wide. The rearward cab doors shall have a radius cutout allowing the door opening to protrude forward over the cab wheel well, while providing full access to the rear crew area. There shall be a heavy duty, piano type, stainless-steel hinge on each door of a minimum pin diameter of 3/8". Hinges shall be slotted for ease of horizontal and vertical adjustment. There shall be a cab door seal and the doors shall close flush with the side of the cab. A heavy duty 6" wide belting material shall be utilized to prevent the cab doors from opening greater than 90 degrees.
PO00010705 - CAB DOOR INSULATION - PREDATOR/SEVERE SERVICE A 1/4" insulation panel shall be installed in each cab door. This insulation panel shall provide an additional acoustical barrier as well as help with heating/cooling properties of the apparatus.
PO00001646 - CAB DOORS -BOLT ON WEATHER STRIP
The cab doors shall be equipped with a weather strip seal track on the lower portion of the door. Bolt-on tracks shall be provided to allow for a snap-on replaceable weather stripping to be changed easily and shall be fastened in place with nutserts to ensure longevity.
***SPECIAL: SP00037866 - PREDATOR SS DOOR LATCHES, HD CASTED LATCH - BARRIER HEIGHT DOORS Heavy-duty, bright finish cast paddle latches shall be provided on the interior and exterior of each cab door.
Door latch mechanisms which utilize spring steel clamps shall not be considered due to their tendency to both rust and break. The interior door latch cables/rods are to be designed to reduce adjustment or possible wear at the adjustment turnbuckles.
Clarification: The FDNY style latch with the lock mechanism inside the paddle latch will be used.
PO00012476 - KEY MODEL #751
The specified door lock cylinder/s shall be equipped with #751 key/s.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 17 of 140 PO00001652 - WINDOWS, MANUAL HAND CRANK STYLE
Each side cab door shall have a tinted retractable window operated by a hand crank mechanism.
The window track shall be designed into the door frame extrusion, which shall be extruded with a track groove to house a window track and seal.
The window shall be capable of being removed from an access slot designed in the bottom of the door frame.
PO00010606 - DOOR WINDOW TRIM EXTRUSION, 4 DOOR
Each side cab door window shall be designed with a custom extruded trim plate, which shall conform to the perimeter of the window opening in each door.
The trim plate shall extend from the edge of the door skin to the window and shall have a silver anodized finish.
PO00001657 - UPPER INTERIOR DOOR PANELS - UPHOLSTERED, 4 DOOR The upper section of each interior cab door panel shall be covered with an upholstered door panel.
Each door shall be upholstered with a Durawear material that matches the color of the interior.
This panel shall terminate approximately 10" above the floor level.
PO00010942 - BRUSHED ALUMINUM DOOR SCUFF PLATES, 4 DOOR The lower and full width portion of each door interior shall have smooth brushed finished aluminum scuff plates to provide maximum wear protection.
These plates shall extend above the inside cab floor level when the doors are closed. ***SPECIAL: SP00037886 - V98 CHEVRONS ON INTERIOR OF CAB DOOR PANELS Four (4) V98 chevron reflective signs shall be installed on the lowest portion of the inner door panels.
The signs shall match the rear body chevron and the seams shall include the black pin striping.
There will be one (1) on each door. These chevrons shall cover at least 962 in.
PO00010304 - WINDSHIELD, 100" CAB
A two piece, symmetrical, safety glass windshield shall be provided on the cab for the driver and officer providing a clear viewing area.
The windshields shall be full width to the center of the front cab support for each side and provide the occupants with a panoramic view.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 18 of 140 To provide enhanced peripheral vision on each side of the cab, the windshield and cab structure shall be designed with radius corners, which provide a minimum of 8" of glass area, measured from the glass face to the side edge near the door post.
The windshield shall consist of three (3) layers, the outer light, the middle safety laminate and the inner light.
The thick outer light layer shall provide superior chip resistance, the middle safety laminate layer shall prevent the windshield glass pieces from detaching in the event of breakage and the inner light shall provide yet another chip resistant layer.
The windshield will be a contour design with 3244 sq. in. of area for improved visibility and style.
The windshield glass shall be designed so it can be used on either the driver or officer side.
Single piece windshields that utilize epoxy or that are bonded to the cab structure shall not be acceptable.
PO00025656 - WINDSHIELD WIPERS & WASHERS - 100"
Dual, electric operated, pantographic type windshield wipers shall be provided.
One (1) electric drive motor shall be provided for each wiper.
Wipers shall have "HI/LO" and "INTERMITTENT" operating speeds. "HI/LO" speeds shall be controlled by a steering column control, within the turn signal control stem. "INTERMITTENT" operation shall be controlled by a twist switch within the control on the steering column.
The wipers shall be of the self-parking type.
Windshield washers shall be electric operated wet-arm type with a 1/2-gallon washer fluid reservoir, mounted behind a hinged access door in the officer side front cab step well area. The fluid level shall be visible through a cutout in the access door. This door shall be secured with two thumb latches.
The washer control shall be integral with the intermittent wiper control switch.
There shall be individual removable panels on the front face of the cab for access to the wiper motor assemblies.
Windshield wipers shall survive testing in excess of 3 million cycles in accordance with section 6.2 of SAE J198 “Windshield Wiper Systems – Trucks, Buses and Multipurpose Vehicles”.
The bidder shall certify that the wiper system design has been “Third party tested” and that the wiper system has met these criteria.
PO00010310 - DELETE SIDE VIEWING WINDOWS
The windows provided on each side of the cab behind the forward cab doors shall be deleted.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 19 of 140 PO00001688 - DARK TINT WINDOWS, SIDE VIEWING, REAR DOORS & REAR WALL The windshield and the forward cab door glass shall be provided with standard DOT, green automotive tint.
If provided, the side cab windows to the rear of the front doors, the rear cab door windows, and any rear viewing windows shall be equipped with a dark, automotive tint.
PO00001699 - GRAB RAILS EXTERIOR, KNURLED ALUMINUM EXTRUSION 1-1/4" diameter x 28" long, knurled bright anodized aluminum handrails shall be provided.
There will be one (1) at each cab door entrance.
Grab rail stanchions shall be chrome plated and offset when necessary to prevent "hand-pinching" when opening or closing the doors.
Formed rubber gaskets shall be provided between each stanchion base and the cab surface. ***SPECIAL: SP00008256 - PREDATOR SS INTERIOR GRAB HANDLES - WHEELABRATED Grab rails shall be provided to assist in entry and exiting of the cab. Each grab rail shall be a cast aluminum "D" style handle that shall have a wheel abraded finish and shall be located in the following locations:
• One (1) 11" long, horizontally mounted on each front cab door on the interior door panel • One (1) 11" long, horizontally mounted on each rear cab door on the interior door panel • One (1) 11" long mounted on an angle forward of each front cab door paddle handle.
PO00010631 - INTERIOR GRAB RAILS -REAR CREW DOORS-BALL-BURNISHED One (1), horizontally mounted, on each rear cab door, located at the same height as the window in the lowered position.
PO00010617 - FRONT CAB GRILLE - SQUARE POLISHED STAINLESS-STEEL A square mirror finished stainless-steel grille shall be installed to allow for maximum air flow to the charge air cooler and the radiator. The top of the grille will have a flat area for the manufacturer’s emblem.
A four (4) inch wide solid band shall extend across the middle of the grill for lettering or lighting options.
PO00025607 - SIDE CAB GRILLES -RECTANGLE STAINLESS-STEEL Two (2) rectangular, mirror finished stainless-steel air inlets/outlets shall be provided horizontally above the wheel well opening, one on each side of the cab.
The grilles shall be equipped with a mesh screen to serve as a secondary ember separator.
The design shall permit proper ducting of air through the engine compartment and cooling system.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 20 of 140 This system shall be such that particles larger than .039 inches (1 mm) in diameter cannot reach the air filter element.
PO00024784 - EXTERIOR CAB TREAD PLATE OVERLAY, BLACK
The specified exterior cab tread plate shall be black in color. Where the tread plate is a stepping surface, it shall be covered in a black line-x type material.
PO00001719 - STAINLESS-STEEL CAB WHEEL WELL LINERS
The front, cab wheel wells shall be equipped with fully removable, bolt-in,12-gauge, stainless-steel inner wheel well liners.
The liners shall extend full depth into the truck frame.
The completely washable wheel well liners shall be designed to protect the cab substructure, inner panels, and other miscellaneous installed components from road salts, debris, dirt accumulation and corrosion. ***SPECIAL: SP00019974 - INSULATION IN CAB FENDER WELLS Insulation will be provided inside the cab fender wells above the liners to reduce the amount of hot air penetrating the cab interior.
Clarification: The cab fender wells need to be completely enclosed with insulation and metal bolt on panels.
PO00001721 - STAINLESS-STEEL CAB FENDERETTES
The cab wheel well openings shall be trimmed with replaceable, bolt-in, polished stainless-steel fenderettes.
The fenderettes shall be secured to the cab with stainless-steel threaded fasteners along the internal perimeter of the wheel well.
Dissimilar metal tape and black vinyl trim molding shall be used where the cab and fender meet.
PO00010933 - FRONT MUD FLAPS
Heavy duty, black rubber type mud flaps shall be provided behind the front wheels.
PO00025669 - RAMCO - RADIUS MOUNTED MIRROR - 6001 SERIES Two (2) Ramco model 6001 PCHR polished aluminum, full face, heated, remote operated, 13 inches high X 9 3/4 wide mirrors, with a bottom heated / remote convex mirror, on a standard arm length of 15 inches shall be provided and installed.
The flat glass and bottom mirror head shall be remote operated with controls on the driver's lower wing panel.
The mirror head shall be attached to a polished aluminum arm mounted on the cab radius panel.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 21 of 140 PO00025677 - MIRROR CONTROL
In addition to the switches on the driver's lower wing panel, the mirror position and heat (if applicable) controls shall be programmed into the multiplex control screen.
PO00011699 - DOOR WIDTH, X-MFD, LFD & X-LFD - 100" SEVERE SERVICE - 37" Cab Entry Door Width Dimensions:
• Forward door opening 37" wide
• Rear door opening 37" wide
Cab Entry Step Dimensions:
• Forward door recessed step 29 3/4" wide x 8-1/2" deep • Rear door recessed step 25 3/4" wide x 8-1/2" deep
PO00010643 - INTERIOR TRIM- GRAY DURAWEAR
The cab interior shall be constructed to create an ergonomically designed interior to be user friendly and functional for the driver and officer.
All interior upholstery panels shall be gray in color.
The upholstered cab overhead and side wall portions shall utilize Durawear upholstery with padding underneath to provide additional insulation.
***SPECIAL: SP00019976 - HD SOUNDPROOFING/ INSULATION PACKAGE BELOW ENTIRE CAB FLOOR Premium soundproofing/insulation material shall be installed below the entire cab floor. Barymat BTRLAX3- 14BY will be installed in these areas. To ensure a clean, smooth surface, this material shall be retained by flat aluminum panels fastened to studs that are welded to cab as needed. These panels shall be removable. Any gaps in this insulation barrier shall be sealed with 3M #425 aluminized high temperature tape. The underside cab insulation will extend to the rear cab wall under the entire crew area.
PO00002964 - INTERIOR CAB WALL GRAY DURAWEAR UPHOLSTERY The interior rear wall of the cab shall be covered with gray Durawear for durability and shall match the other upholstered areas of the cab.
PO00010318 - BARYFOL FLOORING
The floor of the driver’s compartment and the floor of the crew area shall be lined with Baryfol vinyl composite flooring to comply with NFPA noise and heat requirements.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 22 of 140 PO00010317 - 1" ACOUSTICAL INSULATION
One (1) inch thick acoustical insulation shall be provided on the cab roof, rear and side walls of the cab.
This material shall be fitted between the cab structural members and secured with adhesive to provide an insulation barrier for noise and heat.
PO00011692 - ENGINE ENCLOSURE 100" PREDATOR SS (DURAWEAR) The forward portion of the engine enclosure shall be covered with a Durawear material formed overlay to match the balance of the cab interior. To allow maximum "elbow room" for the driver and officer, the forward portion of the engine enclosure shall feature a contour shape. The engine enclosure shall not significantly obstruct the driver's vision in any direction. The enclosure shall be an integral part of the cab structure, which shall be constructed from material providing adequate strength to support radio, map boxes, etc. The engine enclosure shall be insulated to protect from heat and sound. The noise insulation shall keep the DBA level within the limits stated in the current NFPA series 1901 pamphlet.
PO00026126 - S2020 ENGINE ENCLOSURE ACCESS
A composite, hinged access door shall be provided in the top rearward portion of the engine enclosure. The door shall allow access to the engine oil, transmission fluid, power steering fluid level dipsticks. The access door shall be provided with a flush mounted latch. The underside of the access door shall be insulated.
PO00026118 - HD MILCUT SOUNDPROOFING/ INSULATION PACKAGE UNDER ENGINE ENCLOSURE The underside of the engine enclosure shall be overlaid with Milcut, MilShield insulation. MilShield can withstand temperatures up to 1300°F. To ensure a clean, smooth surface, this material shall have a heavy aluminum foil covering and shall be retained by aluminum panels fastened to the cab structure as needed.
Any gaps in this insulation barrier shall be sealed with 3M #425 aluminized high temperature tape.
PO00011646 - HD SOUNDPROOFING/INSULATION BETWEEN UPHOLSTERY & ENGINE ENCLOSURE To further reduce the noise and heat levels inside the cab, 1/4" foam upholstery material shall be installed on all interior surfaces of the engine enclosure, below the upholstery material.
PO00011656 - TREADPLATE SCUFF PLATES ON ENGINE ENCLOSURE - REAR An tread plate scuff plate shall be provided on the vertical surface of the rear engine enclosure.
The scuff plates shall extend a minimum of 6" above the floor.
PO00012473 - SUN VISORS, PREDATOR CAB, DARK POLYCARBONATE To provide maximum protection for the driver and officer, two (2) dark polycarbonate sun visors shall be mounted in the cab overhead on each side.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 23 of 140 ***SPECIAL: SP00017049 - KNEE BOLSTER GLOVE BOX
Provide a knee bolster glove box below the officer side front dash with two (2) Black Southco thumb latches (non-locking). Officer side glove box door will include a painted door and the hinge will be welded to the door.
PO00024654 - OVERHEAD PANEL, FABRICATED CENTER THREE WING PANEL An overhead console with a center three piece removeable panel assembly shall be provided on the cab roof between the driver and officer to permit installation of the multiplex smaller sized control screens and other components as space allows.
The overhead console shall be painted to match the interior of the cab.
The overhead console shall not obstruct the driver's vision through the officer's side window.
PO00012071 - SEAT AND SEAT BELT ANCHOR TESTING
Each seat belt anchor shall be tested to withstand 3,000lbs. of pull on both the lap and shoulder belt in accordance with FMVSS 210 section 4.2.
Each seat mounting position shall be tested to withstand 20G's of force in accordance with FMVSS 207 section
4.2(c).
Both tests shall be performed and verified at a third-party testing and evaluation center. ***SPECIAL: SP00037883 - STORAGE COMPARTMENTS UNDER FRONT SEATS There shall be a compartment provided under each front seat. Each compartment shall be accessible from the front of the seat riser when the door is opened. Non-locking Black Southco thumb latches shall be utilized to match the other cab interior compartments. Protection panel shall be provided within the compartments to isolate wiring from the storage areas.
***SPECIAL: SP00025661 - DRIVERS SEAT, BOSTROM PACIFICA AIR SUSPENSION The driver seat shall be an HO Bostrom EX6 Pacifica with air ride suspension. The seat back will have manual recline with the handle in front of the bottom cushion. The seat cushion will raise, lower, and move forward and back with an electric switch. The seat will be covered with black Durawear plus with red topstitching. The foam cushions will be encapsulated with a blue vinyl compound to prevent gas storage.
The seat shall be equipped with a 3-point shoulder harness with lap belt. The seat belt retractor and mount shall be attached to the B-post.
***SPECIAL: SP00025662 - OFFICERS SEAT, BOSTROM PACIFICA AIR SUSPENSION The officer seat shall be an HO Bostrom EX6 Pacifica with air ride suspension. The seat back will have manual recline with the handle in front of the bottom cushion. The seat cushion will raise, lower, and move forward and back with an electric switch. The seat will be covered with black Durawear plus with red topstitching.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 24 of 140 The seat shall be equipped with a 3-point shoulder harness with lap belt, The seat belt retractor and mount shall be attached to the B-post.
***SHOP NOTE: SR00152705 - SP00008289 - SEAT CUSHION CLARIFICATION The seat cushions for the driver and officer shall be 20" wide.
PO00001980 - FORWARD FACING SEAT POSITION - NO BACK, OUTBOARD, OFFICER SIDE The officer's side outboard, forward facing, crew seat position shall be provided.
The inner rear wall of the cab will serve for back support.
The seating position shall be equipped with a red, 3-point, shoulder harness with lap belt. ***SPECIAL: SP00019987 - FLIP UP SEAT, FORWARD FACING, OUTBOARD, OFFICER SIDE The officer's side outboard, forward facing, crew seat shall have a flip-up style seat.
For Clarification: The flip up seat cushion shall be a Bostrom Pacifica Flip-up cushion in black Durawear plus, red top stitching.
***SPECIAL: SP00025663 - (2) BOSTROM PACIFICA FORWARD FACING, CENTER Two (2) center inboard forward-facing crew seats shall be provided. Each seat shall be Bostrom Pacifica high back with manual recline with the handle in front of the bottom cushion and manual 9” fore/aft adjustment.
The seat will be covered with black Durawear plus with red topstitching. The foam cushions will be encapsulated with a blue vinyl compound to prevent gas storage. The seats shall be equipped with a red 3-point shoulder harness with lap belt.
All seats must completely recline. No limit.
***SPECIAL: SP00037876 - CENTER SEAT BASE WITH COMPARTMENTS. - PAINT DOORS - BOLT IN - LFD, XLFD The two (2) forward facing, center rear seats shall be mounted on an aluminum storage riser that shall be mounted along the rear inside wall of the cab. The riser shall span the width of the seats. The front edges of the seat cushions shall overhang 2" beyond the front surface of the riser.
The riser shall be painted to match the interior of the cab and shall have Four (4) individual, painted compartment doors with Southco latches. Two (2) doors on the front face of the riser and one (1) on each end.
One (1) Amdor Luma-Bar LED light strips approximately 30" long shall be provided on the upper front inside corner of the riser, centered above each front compartment door. Each of the five (5) doors shall be equipped with a switch to control all of the light strip.
***SPECIAL: SP00019986 - BOSTROM SEATING MATERIAL, BLACK DURAWEAR PLUS W/ RED TOPSTITCHING The Bostrom seats shall be upholstered with BLACK DURAWEAR PLUS WITH RED TOP STITCHING.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 25 of 140 PO00024054 - SEAT ADJUSTMENT NOTICE
If equipped, adjustable seats may be limited by outside factors such as optional installed equipment (i.e., EMS compartments, battery chargers, SCBA cylinder brackets) and seat placement.
PO00025679 - CLASS ONE VEHICLE DATA RECORDER
A Class 1 Vehicle Data Recorder (VDR) system shall be provided.
The system shall include an NFPA compliant, "Black Box" with reporting software that shall be capable of data storage to coincide with the NFPA requirements.
Data storage capabilities shall include interfaces with the following systems:
• Display module (Master Optical Warning Device)
• VDR, date time stamp
• Max Vehicle speed (MPH)
• Vehicle acceleration / deceleration (MPH/Sec.)
• Engine Speed (RPM)
• ABS event
• Data password protected
• Data sampled once per second, in 48-hour loop
• Data sampled min by min for 100 engine hours
• Throttle position (% of Throttle)
• Data software
• PC / Mac Compatible
• Data summary reports
The VDR data shall be downloadable by USB cable to a computer using either Microsoft or Apple operating systems.
PO00025680 - CLASS ONE SEAT BELT WARNING SYSTEM - UP TO 6 POSITIONS The apparatus shall be equipped with a Class 1, seat belt warning system.
The system shall consist of a seat belt module and shall display the seating positions through the main, UltraView screen.
PO00010779 - FIVE (5) SEATING POSITIONS
Seat belt and seat cushion sensors shall be provided on the five (5) specified seating positions.
PO00024619 - DELETE - 4FRONT - FRONTAL AIR BAG PROTECTION SYSTEM ***SPECIAL: SP00037864 - DRIVER SIDE EMS COMPARTMENTS
Clarification: Provide additional insulation inside the rear facing crew seat risers.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 26 of 140
EMS CAB STORAGE COMPARTMENTS WITH HINGED DOORS - DRIVER'S SIDE The ideal height of these compartments will be from the rear facing seat riser to the ceiling.
LOWER COMPARTMENT
A storage compartment shall be provided in the cab in lieu of the driver's side rearward facing crew seat. This compartment shall be approximately 24" deep x as tall as possible x 22 3/4" wide with an external door opening approximately24.25 high x 20" wide.
The lower compartment shall be constructed of aluminum and be equipped with an external door and internal door. The outside surfaces (inside the cab) will be painted with textured paint to match the interior color of the cab. The inside surfaces of the compartment will be painted job color with webbing to match the body compartments.
Clarification: The customer (Hemet, CA) will NOT mount a cooler in the cab so the interior EMS compartment door can open full length.
Brushed stainless-steel door sills will be provided on the bottom of the outside cab compartments door openings.
The external access door will be flush mounted and equipped with a forward hinge and locking D ring keyed #751. The door shall be held in the open position by a gas shock stay arm and will open to the rear. Clarification:
The mount for the exterior cab EMS doors will be modified and reinforced so it does not bend when stress is applied from the gas shock. The outside surface of the door will be painted to match the exterior of the cab.
The inside surface will be painted job color with webbing to match the interior surfaces of the compartment.
The in cab access door will be hinged on the inboard edge and held closed by black SouthCo thumb latches.
The internal door will be held open with a gas strut. The inside surface door will also be painted job color with scratch resistant webbing to match the interior surfaces of the compartment. The outside surface of the access door inside the cab will be painted to match the cab interior.
FLOOR VENT
One (1) vent with a rectangular punched grille, metal mesh backing, and replaceable filter will be provided in the lower compartment floor. The vent will be located in the forward, inboard corner of the compartment floor and open to the wheel well below. DO NOT CUT VENT HOLES IN THE SIDEWALLS.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 27 of 140
UPPER COMPARTMENT
One (1) in-cab access only compartment will be incorporated above the lower compartment described above.
This compartment will enclose the area above the lower compartment to the ceiling or as tall as possible. The outside surfaces (inside the cab) will be painted with textured paint to match the interior color of the cab. The inside surfaces of the compartment will be painted job color with webbing to match the body compartments.
A vertically hinged door, with the hinge on the inboard edge, will be provided and held closed by one (1) black SouthCo thumb latch. The internal door will be held open with a gas strut. The interior surface of this door will be painted to match the interior of the compartment described above. A vent hole will NOT be provided in the upper compartment.
Bump stops will be provided as necessary to prevent the doors from contacting any objects in the cab when opened.
The interior of the compartments shall be finish painted job color with a scuff resistant webbing type paint of a contrasting color applied over the painted surfaces.
The driver's side EMS compartments shall be equipped with two (2) Amdor LED interior light(s), one (1) in the lower compartment and one (1) in the upper compartment. The lighting shall be wired to automatically activate when the respective compartment door is open, and the master battery switch is in the "on" position.
Clarification: The light in the lower EMS compartments will be mounted to the ceiling as forward to the compartment, above the door hinge bracket.
The interior EMS compartment door latch shall be equipped with a keyed lock. #751
FLOOR COVERING - TURTLE TILE
The driver side external EMS compartment floor will be covered with black Turtle tile with an outer ramp. The turtle tile will be mechanically fastened.
The upper interior storage area will have black Turtle tile installed, it "will not" be mechanically fastened. ***SPECIAL: SP00037863 - OFFICER SIDE EMS COMPARTMENTS
Clarification: Provide additional insulation inside the rear facing crew seat risers.
EMS CAB STORAGE COMPARTMENTS WITH HINGED DOORS OFFICER'S SIDE The ideal height of these compartments will be from the rear facing seat riser to the ceiling.
LOWER COMPARTMENT
A storage compartment shall be provided in the cab in lieu of the officer's side rearward facing crew seat. This compartment shall be approximately 24" deep x as tall as possible x 22 3/4" wide with an external door opening approximately24.25 high x 20" wide.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 28 of 140 The lower compartment shall be constructed of aluminum and be equipped with an external door and internal door. The outside surfaces (inside the cab) will be painted with textured paint to match the interior color of the cab. The inside surfaces of the compartment will be painted job color with webbing to match the body compartments.
Clarification: The customer (Hemet, CA) will NOT mount a cooler in the cab so the interior EMS compartment door can open full length.
Brushed stainless-steel door sills will be provided on the bottom of the outside cab compartments door openings.
The external access door will be flush mounted and equipped with a forward hinge and a locking D ring keyed #751. The door shall be held in the open position by a gas shock stay arm and will open to the rear. Clarification:
The mount for the exterior cab EMS doors will be modified and reinforced so it does not bend when stress is applied from the gas shock. The outside surface of the door will be painted to match the exterior of the cab.
The inside surface will be painted job color with webbing to match the interior surfaces of the compartment.
The in cab access door will be hinged on the inboard edge and held closed by black SouthCo thumb latches.
The door will be held open by a gas strut. The inside surface door will also be painted job color with scratch resistant webbing to match the interior surfaces of the compartment. The outside surface of the access door inside the cab will be painted to match the cab interior.
FLOOR VENT
One (1) vent with a rectangular punched grille, metal mesh backing, and replaceable filter will be provided in the lower compartment floor. The vent will be located in the forward, inboard corner of the compartment floor and open to the wheel well below. DO NOT CUT VENT HOLES IN THE SIDEWALLS.
UPPER COMPARTMENT
One (1) in-cab access only compartment will be incorporated above the lower compartment described above.
This compartment will enclose the area above the lower compartment to the ceiling or as tall as possible. The outside surfaces (inside the cab) will be painted with textured paint to match the interior color of the cab. The inside surfaces of the compartment will be painted job color with webbing to match the body compartments.
A vertically hinged door, with the hinge on the inboard edge, will be provided and held closed by one (1) black SouthCo thumb latch. The door will be held open with a gas strut. The interior surface of this door will be painted to match the interior of the compartment described above. A vent hole will NOT be provided in the upper compartment.
Bump stops will be provided as necessary to prevent the doors from contacting any objects in the cab when opened.
The interior of the compartments shall be finish painted job color with a scuff resistant webbing type paint of a contrasting color applied over the painted surfaces.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 29 of 140 The officer's side EMS compartment shall be equipped with two (2) Amdor LED interior light(s), one (1) in the lower compartment and one (1) in the upper compartment. The lighting shall be wired to automatically activate when the respective compartment door is open, and the master battery switch is in the "on" position.
Clarification: The light in the lower EMS compartments will be mounted to the ceiling as forward to the compartment, above the door hinge bracket.
The interior EMS compartment door latch shall be equipped with a keyed lock. #751
FLOOR COVERING - TURTLE TILE
The officer side external EMS compartment floor will be covered with black Turtle tile with an outer ramp. The turtle tile will be mechanically fastened.
The upper interior storage area will have black Turtle tile installed, it "will not" be mechanically fastened. ***SPECIAL: SP00003819 - Tread Plate Foot Pads
An aluminum tread plate foot pad shall be provided for the driver and officer seating position.
This foot pad shall be overlaid on top of the standard flooring. ***SPECIAL: SP00037875 - MAP STORAGE - CUSTOM
The customer designed map book storage module shall be provided. The customer will provide a design for KME engineering. An approval drawing shall be provided. ***SPECIAL: SP00037874 - ENGINE ENCLOSURE STORAGE MODULE A storage compartment shall be mounted to the rear of the engine enclosure. The compartment shall be approximately 14" deep x 14" high x AS WIDE AS POSSIBLE BETWEEN THE EMS COMPARTMENTS.
The compartment shall be constructed of smooth aluminum and shall be equipped with a lift up style door hinged toward the front of the cab at the top of the compartment (resembling a toolbox). The door shall be held open by gas shocks and shall be held closed by two (2) black SouthCo M1 thumb latches. The compartment shall be painted matching the interior color of the cab.
An Amdor Luma-Bar LED light strip shall be provided on the forward corner near the hinge. ***SPECIAL: SP00008318 - MOBILE TERMINAL AREA
There shall be a flat surface area in front of the officer for placement of a laptop computer.
A 3/4" high lip will be provided to stop items falling off the area.
PO00010642 - OFFICER FOLD DOWN FOOTREST ON FIREWALL
A fold down footrest shall be provided on the firewall electrical access panel, in front of the officer's seating position.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 30 of 140 The footrest shall be designed with a 14" wide x 3" deep foot rest plate.
PO00025612 - HEATER/DEFROSTER & ACCESSORIES, RAISED ROOF, NON-RM AERIAL, EXTREME DUTY A climate-control system shall be provided for total cab environmental comfort as well as provide heat, cooling and defrost capabilities to various areas in the cab.
The system shall consist of a single evaporator unit, mounted in the center overhead of the cab.
The ceiling mounted external evaporator/heater unit shall include the following:
• Heavy-duty, high output blower.
• High efficiency coil that includes "rifled" tubing and oversized header tubes for maximum refrigerant distribution.
• Four (4) 2" diameter, adjustable louvers; two (2) each side of the cab overhead, facing the driver and officer seat positions.
• Six (6) larger louvers evenly spaced, forward of the overhead assembly, facing the windshield. • Multi-vent defroster louvers positioned above the windshield will provide adequate airflow for windshield defrost.
• Four (4) lower vents shall be provided, one (1) below the driver and officer seat positions and one (1) under each outboard rear facing crew seat.
• Twelve (12) vents shall be provided on the HVAC unit for crew comfort. • Damper controls shall be pneumatically operated to provide air discharge to the windshield, front overhead air discharge louvers as required.
• An adjustable electric water valve to control the amount of heat. • Housing shall be fully insulated and enclosed.
• BTU: 69,000 A/C
• BTU: 72,100 Heat
• CFM: 680 Heat as mounted in the cab
• CFM: 680 A/C as mounted in the cab
The ceiling mounted evaporator unit/s shall be designed with an ergonomically designed cover to provide maximum headroom and a pleasing appearance with a crinkle coat texture and include a deep well condensate collection pan, which shall be drained by a gravity system into the rear corners of the engine compartment utilizing stainless-steel drain poles.
Evaporator units shall be mounted on the cab roof, enclosed by aluminum panels painted white. The evaporator louvers and controls shall penetrate the cab roof into occupant compartments to the least extent practicable. Evaporator units shall be mounted on the cab ceiling, enclosed by a black painted aluminum cover.
A serviceable foam intake filter shall be installed on the rear of the evaporator.
All defrost/heating systems will be plumbed with one (1) seasonal shut-off valve mounted in the officer side wheel well area.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 31 of 140 A 12-volt roof top dual condenser shall be mounted on the cab roof. The condenser shall be designed with high-performance, long-life fan assemblies with sealed housings and shaft. The condenser and coil design shall include rifled tubing for maximum efficiency. Each coil shall be painted black. The condenser unit must include a receiver drier with a high- and low-pressure switch. The wire harness shall include necessary wiring for the clutch circuit as well as a separate power relay circuit.
Mounting design shall enable easy servicing of all components and unit replacement if necessary.
The system shall utilize one (1) Valeo TM-31 HD engine mounted compressor driven by a Poly “V” serpentine belt installed in accordance with the manufacturer's requirements. The system shall use R134a refrigerant. The air conditioner lines shall be EATON GH001 EverCool SAE J2064 Type E hose secured using EATON E-Z Clip system components.
Air conditioning hoses shall be #10 hose for discharge and #12 hose for suction with steel hose and end fittings provided at the compressor. The heater hose installation shall not incorporate a copper tube manifold.
The air conditioning system shall be configured to only operate when the vehicle's engine is running. The blowers, in both evaporators, shall be in operation whenever the air conditioning system is activated.
Heater-defroster shall have a three-speed electric fan with illuminated controls. The controls system shall actuate the air-distribution system with air cylinders, which are to be separated from the air brake system by an 85-90 psi pressure protection valve.
The 12-volt system for the air conditioners shall have first priority to be load managed.
The heater/defroster unit shall clear the windshield in half-the-time required by SAE standards.
PO00025689 - HVAC CONTROLS
HVAC controls shall be provided on the driver's overhead wing panel, consisting of a mode selector control, front fan speed, rear fan speed, air conditioning on/off and temperature range selection.
The controls shall be clearly labeled, adequately backlit.
The multiplex system control screen shall also contain all controls for the cab HVAC control system.
PO00010681 - CAB TILT SYSTEM
A hydraulic cab lift system shall be provided, consisting of an electric-powered hydraulic pump, fluid reservoir, dual lift cylinders, remote cab lift controls and all necessary hoses and valves.
The cab tilt mechanism shall be custom designed for ease of maintenance and consist of two (2) hydraulic cylinders connect to the cab and the frame assembly.
Hydraulic lines shall be rated at 20,000 PSI burst pressure.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 32 of 140 The hydraulic cylinders shall be equipped with a velocity fuse that protects the cab from accidentally descending when the cab is in the tilt position.
Hydraulic cylinders shall be detachable to allow removal of the engine for major service.
A remote cable operated mechanical cylinder stay bar and release shall be provided to insure a positive lock in the tilted position.
The two (2) rear cab latches shall be of the hydraulic pressure release, automatic re-latching type and provide an automatic positive lock when the cab is lowered.
The tilt pump shall be electric over hydraulic type, with a pressure rating of not less than 4,000 PSI. Additionally, the cab tilt device shall be both electrically and hydraulically interlocked to prevent inadvertent activation of the cab tilt system.
• A "CAB NOT LATCHED" indicator shall be provided in the cab dash-warning cluster. • A dual switch control system shall be provided for the cab tilt, located on the passenger side of the vehicle or on the optional tether control. System shall consist of two (2) position toggle switch along with a rubber covered push button momentary switch, which must be activated for the cab to raise or lower. ***SPECIAL: SP00008328 - AUXILIARY - MANUAL CAB LIFT BACKUP SYSTEM An auxiliary, manual cab, lift backup system shall be furnished inside the passenger side of the pump enclosure or front compartment for use in the event of total electrical shutdown.
The auxiliary cab lift will be located on the inside forward wall of the pump enclosure and will be operational with only the upper officer side pump access panel open.
The cab pump handle will be mounted behind the officer side pump panel.
PO00002186 - CAB TILT SECONDARY SAFETY LOCK
A secondary, swing down, safety bar shall be applied to the driver side cab tilt cylinder with a manual lock to engage the lock, as required for extended service operations.
PO00002189 - PARKING BRAKE/CAB TILT INTERLOCK
The cab tilt control shall be equipped with an interlock.
This shall disable the cab tilt system in the event the parking brake is not applied.
PO00007687 - 110,000 PSI FRAME: DOUBLE MAIN RAIL
The chassis frame shall be assembled in its entirety at the manufacturer's facility. This will prevent any split responsibility in warranty or service.
The frame shall consist of two (2) channels fastened together by cross members.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 33 of 140 All structural fasteners used in the frame shall be Grade 8 hardware. Hardened steel washers shall be used under all bolt heads and nuts to avoid stress concentrations. Top flange shall be free of bolt heads. All spring hangers shall be machined steel castings. Frame assemblies that are welded or assembled with “Huck” type fasteners are not acceptable.”
Each main frame rail shall be 10-1/4" x 4" x 3/8", fabricated from Domex™ 110,000 PSI minimum yield steel, with a minimum section modulus of 18.396 cu in and a resisting bending moment (RBM) of 2,023,560-inch pounds.
Frames are built for the specific apparatus under construction so that no unnecessary holes or modifications are made to the frame assembly.
A full-length inner frame liner 9.44" X 3.63" X 3/8" shall be installed. Total section modulus of each rail, with liner, shall be 33.56 cu in and the total resisting bending moment (RBM) shall be a minimum of 3,691,050 inlbs., per rail.
The chassis frame assembly, consisting of frame rails, cross members, axles and steering gear(s), shall be finish painted before installation of any electrical wiring, fuel system components, or air system components. All components or brackets fastened to the frame rails shall be cleaned, primed and painted prior to being attached to the frame rails.
***SPECIAL: SP00019997 - BUMPER DRAWING FOR CUSTOMER APPROVAL A bumper drawing shall be provided to the customer for approval.
PO00002195 - BUMPER 12" PAINTED 3/8" STEEL BUMPER - ALL CABS A 12" high, 101" wide, painted, steel, front bumper shall be provided.
The bumper shall be constructed from 3/8-inch steel, which shall be designed with 45-degree, welded corners and a 2" flange on the top and bottom.
The ends of the bumper shall be supported by horizontal channels, which shall extend from the frame rails to the sides of the bumper.
The color of the bumper shall match the cab and body base color.
PO00002201 - 16" FRONT BUMPER EXTENSION WITH TREAD PLATE GRAVEL SHIELD The bumper shall be extended 16" with a polished aluminum, tread plate, gravel shield enclosing the top and ends.
PO00023875 - CENTER WELL
One (1) storage well-constructed of 1/8" aluminum shall be installed in the gravel shield. This storage well shall be center mounted between the chassis frame rails. The bottom of the storage well shall have a minimum of four (4) drain holes.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 34 of 140 PO00002220 - ONE (1) HINGED, LATCHED, TREAD PLATE COVER One (1) hinged, latched, aluminum, tread plate cover shall be installed on the storage well located in the center of the bumper extension.
PO00002223 - TURTLE TILE MATERIAL IN CENTER WELL
The center storage well shall be equipped with Turtle Tile material to provide drainage and ventilation of equipment in storage well.
PO00002224 - CENTER WELL - HOSE CAPACITY
The center storage well shall have the desired capacity of:
PO00002229 - CENTER WELL - 50 FEET OF 1-3/4" HOSE
50' of 1 3/4" hose
PO00023948 - HOSE WELL OFFICER SIDE OF BUMPER EXTENSION One (1) storage well-constructed of 1/8" aluminum (will/shall) be installed in the gravel shield. This storage well (will/shall) be located on the officer side of the bumper extension. The bottom of the storage well (will/shall) have a minimum of four (4) drain holes.
PO00002269 - ONE (1) HINGED, LATCHED,TREAD PLATE COVER
One (1) hinged, latched, aluminum, tread plate cover shall be installed on the storage well located in the officer side of the bumper extension.
PO00002272 - TURTLE TILE MATERIAL IN OFFICER SIDE WELL
The officer side storage well shall be equipped with Turtle Tile material to provide drainage and ventilation of equipment in storage well.
PO00002273 - OFFICER WELL - HOSE CAPACITY
The officer storage well shall have the desired capacity of:
PO00002277 - OFFICER WELL - 100 FEET OF 1-3/4" HOSE
100' of 1 3/4" hose
PO00002314 - TWO (2) CHROME PLATED TOW EYES, ABOVE BUMPER Two (2) front chrome plate steel tow eyes shall be fastened directly to the bumper support structure that extends above the bumper through the tread plate gravel shield.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 35 of 140 The tow eyes shall be fastened with grade 8 bolts and nuts.
PO00002322 - FRONT BUMPER - BLACK LINE-X TRIM - TOP EDGE The front bumper top flange and 1" of the front surface shall be sprayed with black Line-X to prevent any damage to the painted surface.
PO00024469 - 22,000# FRONT AXLE STEERTEK, DISC BRAKES
The Steertek NXT front axle beam shall be rated to carry 22,000 lbs. and consist of a fabricated box cross section construction with 100ksi plate and a continuous beam architecture to minimize stress points for added durability.
The axle shall incorporate a removable kingpin feature for ease of kingpin serviceability. The knuckles shall allow for compatibility with disc brakes mounted at the 12 o’clock position and with drum brakes and allow for wheel cut up to 45 degrees. They shall also utilize premium kingpin bushings and seals to provide enhanced protection from the elements to improve bushing life. Oil seals with viewing window shall be provided.
The suspension shall consist of multi-leaf parabolic springs rated at 22,000 lbs. with double wrapped front eye that are packaged within an integrated clamp group that allows for ease of OEM assembly on to the axle beam and reduced part count. The clamp group bolts are tightened on the top of the clamp group opposed to the traditional U-bolt on the bottom making it easier to access with a torque wrench for servicing. The spring shall also include a lower shock attachment with an upturned eye. The springs will contain threaded pin bushings to allow simplification of spring alignment as well as long service life and improved ride quality. The suspension and spring geometry will be optimized to provide improved bump steer and Ackermann. Two ZF Sachs twintube shocks shall be provided with the front suspension assembly. The shocks shall be specially developed for parabolic leaf springs with a digressive characteristic curve using a patented piston system. The shocks shall feature multi-stage piston and base valves. The combination of valves shall achieve the desired damping characteristics that are ideal for the application.
Meritor EX-225 H, 17”-disc brakes shall be provided for the front axle.
The front brakes shall be full air actuated with automatic, slack adjustment.
PO00010598 - STEERING - DUAL SHEPPARD POWER STEERING GEARS A dual power steering system shall be provided utilizing a Sheppard model #M110 main steering gear on the driver side of the chassis and a Sheppard model #M90 steering gear on the officer side of the chassis.
The power steering gear on the officer side of the chassis shall increase performance in turning the officer side wheel assembly, reducing loads and forces on the main gear and components.
The steering system shall be designed to maximize the turning capabilities of the front axle no matter the rating and tire size.
The use of a power assist cylinder on the officer side of the chassis is NOT ACCEPTABLE on front axles of this capacity.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 36 of 140 The system shall be designed utilizing an engine driven hydraulic pump, with a maximum operating pressure of 2000 PSI.
Steering system components shall be mounted in accordance with the steering gear manufacturer's instructions.
PO00010603 - STEERING COLUMN - CLOCK SPRING "NARROW"
The steering column shall be a “Douglas Autotech” tilt and telescope column.
A lever mounted on the side of the column shall control the tilt and telescope features.
The steering shaft from the column to the miter box shall have a rubber boot to cover the shaft slip and a second rubber boot to seal the passage hole in the floor.
There shall be a ergonomically designed, self-canceling lever, that shall control the following functions:
• Left and right turn signals
• High beam activation
• Two speed with intermittent windshield wiper control
• Windshield washer control
PO00010604 - 18" STEERING WHEEL - 4 SPOKE - "NARROW"
The steering wheel shall be a four (4) spoke, vinyl padded, minimum 18" diameter, with a center hub mounted horn button.
PO00010600 - POWER STEERING FLUID - COOLING SYSTEM
A power steering fluid cooling system shall be provided.
The heat exchanger shall be a tube and fin type and shall be a separate unit.
The cooler shall be mounted forward of the radiator and plumbed to the power steering fluid return line.
PO00002358 - 24,000# REAR AXLE MERITORRS-24-160
Rear axle shall be a single, Meritor RS-24-160 with a capacity of 24,000 lbs. (Minimum). Axle shall be a single reduction type and have a gear ratio as required.
Oil seals shall be provided as standard equipment.
PO00002375 - MERITOR, EX-225 17" SA REAR DISC BRAKES, W/ AUTO SLACK ADJUSTERS Meritor EX-225 H, 17”-disc brakes shall be provided for the rear axle.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 37 of 140 The rear brakes will be full air actuated with automatic, slack adjustment.
PO00023915 - VEHICLE TOP SPEED NFPA STATEMENT
The rear axle/s (will/shall) be geared for a vehicle top speed in accordance with NFPA sections 4.15.2 and 4.15.3.
Units with GVWR over 26,000 pounds (will/shall) be limited to 68 mph. If the combined tank capacity is over 1250 gallons of foam and water or the GVWR is over 50,000 pounds, the vehicle top speed (will/shall) be limited to 60 mph or the fire service rating of the tires, whichever is lower.
PO00002433 - HENDRICKSON FIREMAAX, FMX-242 AIR RIDE- SA 24,000# A Hendrickson, "FIREMAAX" model #FMX-242, air ride suspension shall be provided for the single rear axle.
The suspension shall have a weight rating equal to the rear axle weight rating up to 24,000 pounds.
PO00002488 - FRONT WHEELS, POLISHED ALUMINUM, 22.5 X 12.25, 24,000# The front wheels shall be 22.5" x 12.25" ten stud, hub piloted, polished aluminum disc type.
PO00002491 - FRONT WHEELS, LUG AND HUB TRIM (ALUMINUM WHEELS) The front wheels shall be provided with bright nut covers and hub caps.
PO00002500 - FRONT, GOODYEAR 425/65R22.5 L 24,400# G296 MSA MIXED - 68MPH The front tires shall be Goodyear 425/65R22.5, "20 Ply", tubeless, radial G296 MSA, on/off road tread.
The tires shall be fire service rated up to 24,400 lbs. and shall have a top speed of 68 mph when inflated to 120 psi.
PO00002535 - REAR WHEELS, POLISHED ALUMINUM, 22.5 X 8.25, SINGLE AXLE, OUT ONLY The single, rear axle wheels shall be 22.5" x 8.25" ten stud, hub piloted, disc type.
The inner wheels shall be painted steel, the outer wheels shall be polished aluminum.
PO00002553 - REAR WHEELS, LUG AND HUB TRIM, SA (ALUMINUM) The single, rear axle aluminum disc wheels shall be provided with bright nut covers and hub caps.
PO00002567 - REAR, GDYR 11R22.5 H 28,280# ENDURANCE RSA HIGHWAY - 75MPH, SINGLE AXLE The rear tires shall be Goodyear 11R22.5, "16 Ply", tubeless, radial, endurance RSA, highway tread.
The tires shall be fire service rated up to 28,280 lbs. and shall have a top speed of 75 mph when inflated to 123 psi.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 38 of 140 PO00002625 - TIRE PRESSURE MONITORING - LED VALVE STEM CAPS - SIX TIRES Each tire shall be equipped with an LED tire alert pressure management system (Vecsafe equal) that shall monitor tire pressure. A chrome plated brass sensor shall be provided on the valve stem of each tire.
The sensor shall calibrate to the tire pressure when installed on the valve stem for pressures between 20 and 120 psi.
The sensor shall activate an integral battery-operated LED when the pressure of that tire drops 8 psi.
PO00010744 - SPARE ALUM WHEEL /TIRE - 11R X 22.5, 16 PLY, 8.25" A spare 22.5" x 8.25" wheel(s) and 11 R x 22.5, 16 ply tire(s) shall be furnished.
PO00010749 - SPARE ALUM WHEEL/TIRE - 425/65 R X 22.5", 12.25" A spare 22.5" x 12.25" hub piloted wheel(s) and 425/65 R x 22.5, 20 ply tire(s) shall be furnished.
PO00010544 - BRAKE SYSTEM, SINGLE AXLE CHASSIS
A dual circuit, air operated braking system, meeting the design and performance requirements of FMVSS -121 and the operating test requirements of NFPA 1901 current edition shall be installed.
The air system shall provide a rapid air build-up feature and low-pressure protection valve with light and buzzer, designed to meet the requirements of NFPA 1901, current edition.
PO00010546 - ABS BRAKING FOR SINGLE REAR AXLE CHASSIS
An Anti-Skid Braking System (ABS) shall be provided to improve braking control and reduce stopping distance.
This braking system shall be fitted to all of the axles. All electrical connections shall be environmentally sealed, water, weatherproof, and vibration resistant.
The system shall constantly monitor wheel behavior during braking. Sensors on each wheel shall transmit wheel speed data to an electronic processor which shall sense approaching wheel lock causing instant brake pressure modulation up to 5 times per second in order to prevent wheel lockup. Each wheel shall be individually controlled.
To improve service trouble shooting, provisions in the system for an optional diagnostic tester shall be provided. The system shall test itself each time the vehicle is started. A dash-mounted light shall go out once the vehicle has attained 4 mph after successful ABS start-up. A warning light shall signal malfunction to the operator. The system shall consist of a wheel mounted toothed ring, sensor, sensor clip, electronic control unit and solenoid control valve. The sensor clip shall hold the sensor in close proximity to the toothed ring.
The system shall also control application of the auxiliary engine exhaust or drive line brakes to prevent wheel lock.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 39 of 140 PO00002441 - ELECTRONIC STABILITY CONTROL (ESC) WITH (ATC) - CUSTOM SA An Electronic Stability Control (4 or 6 Channel) shall be provided as part of the Standard ABS system. The Electronic Stability Control system is capable of recognizing and assisting in both rollover and vehicle-under and over-steer situations through advanced monitoring of vehicle parameters and automatic and selective application of the chassis brakes. The ESC system monitors the vehicle response to turning and braking and adjusts or modulates the brake pressure at the wheel end to slow the vehicle in roll control, stabilize the vehicle when under or over steering, and modulate brake pressure when excessive wheel slip, or wheel lockup is detected. By these actions, the ESC system helps to maintain the vehicle’s lateral and roll stability at all times and improves braking and steer ability during heavy brake applications and during braking on slippery surfaces.
To further improve vehicle drive characteristics the unit shall be fitted with automatic traction control (ATC).
This system shall control drive wheel slip during acceleration from a resting point. An extra, solenoid valve shall be added to the ABS system.
The system shall control the engine and brakes to ensure efficient acceleration.
The system shall be equipped with a dash-mounted light that shall come on when ATC is controlling drive wheel slip.
The system shall also include an "off road traction" dash mounted switch that will allow the operator to momentarily allow for more wheel slip when the unit is in deep mud or snow.
PO00002450 - AIR RESERVOIRS 4700 CUBIC INCH, SINGLE AXLE, W/800 CUBIC INCH ADDITIONAL TANK -
COLOR CODED
There shall be a minimum of three (3) air reservoirs installed in conformance with best automotive practices.
An additional 800 cu. in. air reservoir shall be provided for an air manifold.
Reservoir capacity total shall be a minimum of 5500 cubic inches.
A pressure protection valve shall be installed to prevent the use of air horns or other air operated devices should the air system pressure drop below 80 psi (552 kPa).
The air reservoirs shall be color coded to match the air lines for easy identification, maintenance, and troubleshooting.
The reservoirs shall be painted the following colors:
• Wet Tank Black
• Primary Tank Green
• Secondary Tank Blue
• Auxiliary Tank(s) Yellow.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 40 of 140 PO00010711 - AUTOMATIC MOISTURE EJECTOR - WET TANK
There shall be a Haldex automatic moisture ejector provided on the wet air tank.
PO00025062 - 1/4 TURN DRAIN VALVES ON ALL AIR TANKS
For ease of daily maintenance, each air system reservoir shall be equipped with a brass 1/4 turn drain valve.
PO00002464 - BENDIX AD-IS SYSTEM, AIR DRYER HEATED
A Bendix AD-IS heated air dryer system shall be furnished. The function of the AD-IS dryer reservoir module (DRM) is to provide an integrated vehicle air dryer, secondary reservoir, purge reservoir, governor, and a number of the charging valve components in a module. The DRM dryer module includes an integrated solution air dryer (AD-IS), a reservoir including a separate purge reservoir section, a governor, and four pressure protection valves which have been designed as an integrated, air supply system.
The function of the AD-IS air dryer is to collect and remove air system contaminants in solid, liquid and vapor form before they enter the brake system. It provides clean, dry air to the components of the brake system which increases the life of the system and reduces maintenance costs. Daily, manual, draining of the reservoirs is eliminated. The function of the pressure protection valves is to both control the order in which the components receive air from the AD-IS air dryer, as well as to protect each reservoir from a pressure loss in the other reservoir or a pressure loss in an air accessory.
An automatic, moisture ejector on the primary or wet tank shall also be furnished.
PO00010319 - COLOR CODED SYNFLEX BRAKE LINES W/QUICK RELEASE FITTINGS - SINGLE AXLE The entire chassis air system shall be plumbed utilizing reinforced, Synflex air lines, which shall be equipped with quick release type fittings.
All of the airlines shall be color coded to correspond with an air system schematic and shall be adequately protected from heat and chafing.
PO00011823 - AIR COMPRESSOR -WABCO - ALL CUMMINS ENGINES Air compressor shall be a Wabco brand, with a minimum of 18.7 cubic feet per minute capacity on L9 X15 models and 25.9 cubic feet per minute on X12 models.
Air brake system shall be the quick build up type.
The air compressor discharge line shall be stainless-steel braid reinforced Teflon hose.
The chassis air system shall meet NFPA 1901, latest edition for rapid air pressure build-up within sixty (60) seconds from a completely discharged air system.
This system shall provide sufficient air pressure so that the apparatus has no brake drag and is able to stop under the intended operating conditions following the sixty (60) seconds build-up time.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 41 of 140 PO00011824 - BRAKE TREADLE VALVE
A Bendix dual brake treadle valve shall be mounted on the floor in front of the driver.
The brake control shall be positioned to provide unobstructed access and comfort for the driver.
PO00002466 - PARKING BRAKE CONTROL - NEAR DRIVER - ALL WHEEL LOCK Parking brake shall be of the spring-actuated type, mounted on the rear axle brake chambers. A red, indicator light shall be provided in the driver dash panel that shall illuminate when the parking brake is applied.
The parking brake will be equipped with all-wheel lock-up.
The parking brake control shall be mounted on the driver lower wing panel.
PO00010714 - ENGINE PACKAGE
PO00026112 - CUMMINS X12 500 HP AT 1700 RPM, 1695 FT. LBS. TORQUE AT 1000 RPM Engine shall be a Cummins, Model X12 500, diesel, turbo-charged, per the following specifications.:
• Max. Horsepower 500 HP @ 1700 RPM
• Governed Speed 2000 RPM
• Peak Torque 1695 lb. ft. @ 1000 RPM
• Cylinders Six (6)
• Operating Cycles Four (4)
• Bore Stroke 5.2 x 5.67 in.
• Displacement 720 cu. in.
• Compression Ratio 16.8:1
• Governor Type Limiting Speed
Engine oil filters shall be engine manufacturers branded or approved equal.
Engine oil filters shall be accessible for ease of service and replacement.
PO00010716 - ENGINE IQA CERTIFICATION - X12
The Cummins X12 engine shall be certified by Cummins Power Systems for installation in the manufacturer’s custom chassis.
PO00002712 - SECONDARY BRAKING - ENGINE COMPRESSION BRAKE An engine compression brake shall be furnished for increased braking capabilities.
Controls shall be as provided by the engine manufacturer and shall be activated by releasing the throttle pedal to the idle position.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 42 of 140 The engine compression brake shall have dash mounted control switches to turn the brake on or off as well as to control the operational level of the brake.
The engine brake shall be wired in such a manner so as to illuminate the chassis brake lights when the engine brake is engaged and operating.
The engine brake shall be interlocked with the PTO operation and shall automatically disengage any time the apparatus is operating with the PTO active.
PO00010493 - ENGINE AIR CLEANER
An engine air cleaner shall be provided. The air cleaner shall include a dry type element and shall be installed in accordance with the engine manufacturer's recommendations.
The air cleaner shall be located to the rear of the engine, with streamline air pipes and hump hose connections from the inlet to the air cleaner and from the air cleaner to the turbo.
The air cleaner shall be easily accessible when the cab is tilted.
The air cleaner shall be plumbed to the air intake system that shall include a self-sealing connection between the cab and air cleaner assembly to allow the cab to be tilted.
To draw fresh clean air, the intake for the air cleaner shall be on the side of the cab on the driver's side.
The inlet shall be a minimum of 41" above the ground to allow the vehicle to navigate through water without any part of the air intake system being below the frame rail, preventing any type of water intake. There will be no exceptions.
PO00010494 - EMBER SEPARATOR
An ember separator shall be installed in the chassis air intake system.
The ember separator housing must be easily accessible when the cab is tilted.
PO00010495 - ACCELERATOR PEDAL - FLOOR MOUNT
A floor mount accelerator pedal shall be installed on the floor in front of the driver.
The pedal shall be positioned for comfort with ample space for fire boots and adequate clearance from the brake pedal control.
PO00010496 - REMOTE THROTTLE & INTERLOCK HARNESS
An apparatus interface wiring harness for the engine shall be supplied with the chassis. If applicable, separate circuits shall be included for pump controls, “Pump Engaged” and “OK to Pump” indicator lights, open compartment ground, start signal, park brake ground, ignition signal, master power, customer ignition, air horn solenoid switch, high idle switch and high idle indication light.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 43 of 140 The engine ECM (Electronic Control Module) discreet wire remote throttle circuit shall be turned off for use with a J1939 based pump controller or when the discreet wire remote throttle controls are not required.
PO00011702 - COOLING/RADIATOR, 100" SS - NARROW
Radiator shall be brass with bolted steel top and bottom tanks. The cooling system shall be designed for a maximum of fifteen (15) PSI operation. There shall be a sight glass in the radiator to check the coolant level without removing the radiator cap. The core construction shall be tube and fin with three (3) tube rows, 273 total core tubes, and fourteen (14) fins per inch. Extended life engine coolant shall provide anti-freeze protection to -30° F. The mixture shall be per the engine manufacture's specifications. Core area be a minimum of 1375 square inches (39 H x 35.25W).
PO00010649 - COOLING SYSTEM CRITERIA
The engine cooling system shall be certified by the engine manufacturer to meet cooling index requirements for a minimum ambient temperature or 110-degrees Fahrenheit.
PO00010650 - TRANSMISSION COOLER
A shell and tube transmission oil cooler shall be provided using engine coolant to control the transmission oil temperature.
The cooler shall have an aluminum shell and copper tubes.
The cooler shall be assembled using pressed in rubber tube sheets to mechanically create a reliable seal between the coolant and the oil.
No brazed, soldered, or welded connections shall be used to separate the coolant from the oil.
PO00010651 - RADIATOR CROSS MEMBER
The radiator installation shall include a radiator cross member for additional strength and durability.
This cross member shall be designed so the angle of approach is not affected.
PO00010652 - HEAVY DUTY RADIATOR SKID PLATE
The radiator installation shall include a heavy-duty radiator skid plate to protect the radiator from debris or obstructions under the chassis.
The skid plate shall be designed so the angle of approach is not affected.
This skid plate design shall include wire cover wing plates for additional protection to wires and hoses on each side of the radiator assembly.
The skid plate shall be painted to match the chassis.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 44 of 140 PO00011676 - CHARGED AIR COOLER (FRONT MOUNT)
The charge air cooler shall be constructed of aluminum with cast aluminum side tanks.
The cooler shall have a frontal core size of 957 square inches, seven (7) fins per inch, and forty-eight (48) core tubes.
The charge air cooler shall be mounted directly ahead of the radiator and to the radiator headers.
Rubber isolators shall be used at the mounting points to reduce transmission of vibrations.
The connections between the engine and charged air cooler, shall be made using high temperature silicone hoses rated for use in temperature up to 500°F, and heavy-duty constant tension T-Bolt spring hose clamps.
PO00023913 - COOLANT FAN W/ CLUTCH CUMMINS X12
The engine cooling system shall incorporate a heavy-duty fan, installed on the engine and include a shroud.
The fan shall be equipped with an air-operated clutch fan, which shall activate at a pre-determined temperature range.
Recirculation shields shall be installed to ensure that air which has passed through the radiator is not drawn through it again.
PO00002711 - SILICONE HEATER AND COOLANT HOSE
All coolant piping shall be constructed of appropriately sized, powder coated, steel tubing with 0.06 wall thickness and formed hose barbs. All connections between coolant pipes and chassis components shall be made using appropriately sized silicone hoses or elbows, rated for use in temperatures ranging from -60F to +500F. These connections shall be minimal in number to reduce the number potential leak points and shall adequately allow for movement of the engine relative to chassis mounted components. All integral hoses supplied with the engine shall be as supplied by the engine manufacturer.
Silicone heater hoses shall be furnished for the heater system within the interior structure of the cab. All heater hoses shall be equipped with constant torque type hose clamps. All integral hoses supplied with the engine shall be as supplied by the engine manufacturer.
PO00023874 - LOW COOLANT INDICATOR
A low engine coolant indicator light located in the dash instrument panel shall be provided. An audible alarm shall be provided to warn of the low coolant condition.
PO00002720 - ALLISON 4000EVS TRANSMISSION - COMPRESSION BRAKE An Allison World Transmission, Model 4000 EVS electronically controlled, automatic transmission shall be provided.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 45 of 140 Transmission specifications shall be as follows:
• Max. Gross Input Power 600 HP
• Max. Gross Input Torque 1850 lb. ft.
• Input Speed (Range) 1700- 2300 RPM
• Direct Gear (Pumping) 4th (Lock-up)
Transmission installation shall be in accordance with the transmission manufacturer's specification.
The transmission shall be readily and easily removable for repairs or replacement.
One (1) PTO opening shall be provided on both the left and right side of the converter housing (positions one (1) o'clock and eight (8) o'clock).
PO00002732 - SIX (6) SPEED AUTOMATIC TRANSMISSION - 4000 SERIES The transmission shall be calibrated for six (6) forward gears and one (1) reverse gear.
Each gear shall have the following ratios:
• First 3.51:1
• Second 1.91:1
• Third 1.43:1
• Fourth 1.00:1
• Fifth 0.74:1
• Sixth 0.64:1
• Reverse -4.80:1
PO00002736 - ALLISON TRANSMISSIONS, ELECTRONIC TOUCH PAD SHIFTER IN CAB An illuminated, touch-pad type, shift control shall be mounted in the cab on the driver's lower wing panel.
Shift control shall be approved by the transmission manufacturer.
PO00010553 - TRANSMISSION OIL LEVEL SENSOR
The transmission shall be equipped with the oil level sensor (OLS); this sensor shall allow the operator to obtain an indication of the fluid level from the shift selector.
The sensor display shall provide the following checks, correct fluid level, low fluid level and high fluid level.
PO00010554 - ALLISON PARK TO NEUTRAL
The transmission, upon application of the parking brake, shall automatically shift into neutral.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 46 of 140 PO00010555 - ALLISON PRESELECT PROGRAMMING
The transmission shall have Allison Preselect enabled to automatically downshift when the secondary engine brake is active.
PO00002740 - PRESELECT PROGRAMMED FOR 4TH GEAR
The transmission shall be programmed to automatically downshift to 4th gear.
This feature shall be enabled/disabled with the main on/off switch for the engine brake.
PO00023876 - TES 295 SYNTHETIC TRANS FLUID 4000 EVS
TES 295 transmission fluid shall be utilized to fill the 4000 EVS transmission.
PO00010794 - TRANSMISSION LOCK-UP
The automatic transmission furnished in the chassis shall have a lock-up assembly which brings the transmission to direct drive and prevents the transmission from shifting gears while in the pumping mode.
A positive braking system shall be provided to prevent vehicle movement during pumping operations.
The air brakes furnished must satisfy this requirement.
PO00010565 - DRIVE LINES DANA-SPICER #1810 SERIES
Drive lines shall be Dana (Spicer) 1810 heavy duty series or equal, with "glide coat" splines on all slip shafts.
The manufacturer shall utilize an electronic type balancing machine to statically and dynamically balance all drive shafts.
The manufacturer shall provide proof of compliance with all drive shaft manufacturer's standards and specifications. {No Exceptions}
Where applicable, the universal joints shall be the half loop style joints.
PO00002748 - 5 GALLON DEF TANK
A five (5) gallon diesel exhaust fluid (DEF) tank shall be provided and installed. The tank shall be mounted in the area of the battery box and shall be accessible through a door in the crew area step well.
The tank shall include an internal heater that will be fed by engine coolant directly from the engine block to ensure it is always kept at the proper temperature per EPA requirements. The tank shall include a temperature sensor to control the flow of the engine coolant from the heater valve to the DEF tank.
A DEF fluid level sensor shall be provided with the DEF tank and connected to the level gauge on the dashboard.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 47 of 140 PO00012469 - DIESEL EXHAUST FLUID LEVEL GAUGE
Diesel Exhaust Fluid level (E-1/2-F); low fuel level warning @ 1/8 tank PO00010556 - EXHAUST SYSTEM - DPF & SCR SYSTEM - INLINE SYSTEM The exhaust system shall be installed in accordance with the engine manufacturer's requirements and meet all Environmental Protection Agency and State noise level requirements.
Exhaust system components shall be securely mounted and easily removable.
The diesel particulate filter/muffler shall be fabricated from stainless-steel and of a size compatible with the engine exhaust discharge.
Exhaust tubing shall be a minimum of 16 gauge stainless-steel from the turbocharger on the engine to the inlet of the diesel particulate filter. Any flexible exhaust tubing shall be HDT stainless-steel type.
To minimize heat build-up, exhaust tubing within the engine compartment shall be wrapped with an insulating material. Exhaust shall be wrapped from the turbocharger to the entrance of the muffler. Material shall be held in place with worm gear type clamps.
An exhaust diffuser shall be provided to reduce the temperature of the exhaust as it exits the tailpipe.
If the electrical system is hardwired or V-Mux multiplex, separate "regeneration" enable and prohibit switches shall be provided under the dashboard on the driver's side. Each switch shall be provided with a spring-loaded protective cover and shall be clearly marked as to function. If the electrical system is Class-1 ES-key, the regeneration switches shall be incorporated into the ultra-view screen.
The vehicle shall be equipped with SCR technology that uses a urea-based diesel exhaust fluid (DEF) and a catalytic converter to significantly reduce oxides of nitrogen (NOx) emissions.
The SCR system shall reduce levels of NOx (oxides of nitrogen emitted from engines) by injecting small quantities of diesel exhaust fluid (DEF) into the exhaust upstream of a catalyst, where it vaporizes and decomposes to form ammonia and carbon dioxide.
PO00010558 - STAINLESS-STEEL EXHAUST TAILPIPE/OUTLET OS - DPF + SCR SYSTEM The exhaust tailpipe extending from the SCR catalyst to the side of the vehicle shall be constructed from 16- gauge stainless-steel tubing.
The exhaust discharge shall be on the officer side of the apparatus forward of the rear axle.
PO00002758 - PLYMOVENT EXHAUST EXTRACTION SYSTEM TAILPIPE ADAPTER The exhaust outlet shall be a straight pipe, forward of the rear axle. It shall be terminating minimum 6" forward of rear tire, minimum 2.5" below rub rail/body, and flush with outboard of rub rail/body to connect with a pneumatic Plymovent ventilation system.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 48 of 140 PO00024553 - FUEL COOLING SYSTEM
A fuel cooling system shall be provided. The heat exchanger shall be a tube and fin type and shall be a separate unit. The cooler shall be mounted forward of the radiator and plumbed to the fuel return line.
PO00002762 - FUEL TANK - 65 GALLON, STEEL
Fuel tank shall be a minimum of sixty-five (65) gallon capacity. It shall have a minimum, fuel filler neck of 2" ID and 1/4 turn fill cap. A 1/2" minimum diameter drain plug shall be provided. The tank shall be fabricated from hot rolled, pickled and oiled steel. Provisions for an additional feed line and fuel level float shall be provided for future use. The fuel tank shall be installed behind the rear wheels between the frame rails. The fuel tank shall meet all FHWA 393.67 requirements including a fill capacity of 95% of tank volume. The fuel tank shall be able to withstand a longitudinal acceleration of -23.0g at 0.166 seconds in accordance with SAE J211 standards using a channel frequency class 600 filter. Testing shall be performed at and verified by a third-party testing and evaluation center.
PO00010567 - STAINLESS-STEEL FUEL TANK STRAPS
The straps supporting the diesel fuel tank shall be made of Type 304L stainless-steel with grade 8, zinc coated steel hardware.
There will be no exceptions.
PO00010568 - FUEL TANK MOUNTING STRAP ISOLATION MATERIAL The fuel tank mounting straps shall utilize dense rubber between the straps and the fuel tank to prevent chaffing.
PO00010569 - FUEL LINES - FIBER REINFORCED HOSE
Fuel lines shall be an Aeroquip FC332 AQP Series fiber reinforced hose. The lines shall be sized to meet engine manufacture's requirements and shall be carefully routed and secured along the inside of the frame rails.
PO00010576 - FUEL LINE SHUT-OFF VALVE
A fuel line shut-off valve shall be provided between the fuel tank and the primary fuel filter.
The valve shall be labeled "Fuel Tank Shut-Off".
No reserve feature shall be included in the tank.
PO00010579 - RACOR 400 SERIES HEATED FUEL - WATER SEPARATOR WITH A Racor 400 series heated fuel filter/water separator shall be provided in the fuel system.
A "water in fuel" indicator shall be provided on the dash.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 49 of 140 PO00026203 - FUEL POCKET, DRIVER SIDE REAR WHEEL WELL PANEL - SIGNATURE 4 A fuel fill shall be provided in the driver side rear wheel well area.
A Signature 4 composite fuel pocket with a brushed stainless-steel door shall be provided.
A label indicating "Ultra Low Sulfur Diesel Fuel Only" shall be provided adjacent to the fuel fill.
PO00010721 - PUMPER BODY ELECTRICAL
PO00011797 - CUSTOM CHASSIS ELECTRICAL SYSTEM
All electrical wiring in the chassis shall be GXL cross link insulated type. Wiring is to be color coded and include function codes every three (3) inches on both sides. Wiring harnesses shall be routed in protective, heat resistant loom, securely and neatly installed. Two (2) power distribution centers shall be provided in central locations for greater accessibility. The power distribution centers shall contain thermal automatic reset breakers, power control relays, flashers, diode modules, daytime driving light module, and engine and transmission data links. All breakers and relays shall have a capacity substantially greater than the expected load on the related circuit, thus ensuring long component life. Power distribution centers shall be composed of a system of interlocking plastic modules for ease in custom construction.
The power distribution centers are function oriented. The first is to control major truck function. The second shall control center to overhead switching and interior operations. Each module is single function coded and labeled to aid in troubleshooting. The centers will also have accessory breakers and relays for future installations. All harnesses and power distribution centers shall be electrically tested prior to installation to ensure the highest system reliability.
All external harness interfaces shall be of a triple seal type connection to ensure a proper connection. The cab/chassis and the chassis/body connection points shall be mounted in accessible locations. Complete chassis wiring schematics shall be supplied with the apparatus.
PO00022590 - 12-volt ELECTRICAL SYSTEM TESTING - ALL UNITS The apparatus low voltage electrical system shall be tested and certified by the manufacturer. The certification shall be provided with the apparatus. All tests shall be performed with the air temperature between 0°F and 100°F.
The following three (3) tests shall be performed in order. Before each test, the batteries shall be fully charged.
The engine shall be started and kept running until the engine and engine compartment temperatures are stabilized at normal operating temperatures and the battery system is fully charged. The engine shall be shut off and the minimum continuous electrical load shall be activated for 10 minutes. All electrical loads shall be turned off prior to attempting to restart the engine. The battery system shall then be capable of restarting the engine. Failure to restart the engine shall be considered a test failure.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 50 of 140 The minimum continuous electrical load shall be activated with the engine running at idle speed. The engine temperature shall be stabilized at normal operating temperature. The battery system shall be tested to detect the presence of battery discharge current. The detection of battery discharge current shall be considered a test failure.
The total continuous electrical load shall be activated with the engine running up to the engine manufacturers governed speed. The test duration shall be a minimum of 2 hours. Activation of the load management system shall be permitted during this test. However, an alarm sounded due to excessive battery discharge, as detected by the system, or a system voltage of fewer than 11.7 volts DC for a 12-volt system, for more than 120 seconds, shall be considered a test failure.
Following completion of the preceding tests, the engine shall be shut off. The total continuous electrical load shall be activated and shall continue to be applied until the excessive battery discharge alarm is activated.
The battery voltage shall be measured at the battery terminals. With the load still applied, a reading of fewer than 11.7 volts shall be considered a test failure. The battery system shall then be able to restart the engine.
At the time of delivery, documentation shall be provided with the following information:
• Documentation of the electrical system performance test A written load analysis of the following:
• Nameplate rating of the alternator
• Alternator rating at idle while meeting the minimum continuous electrical load • Each component load comprising the minimum continuous electrical load. • Additional loads that, when added to the minimum continuous load, determine the total connected load. • Each individual intermittent load.
PO00011798 - CUSTOM CHASSIS WIRING INSTALLATION
The wiring harness contained on the chassis shall be designed to utilize wires of stranded copper or copper alloy of a gauge rated to carry 125% of maximum current for which the circuit is protected without exceeding 10% voltage drop across the circuit. Wiring shall be uniquely identified by color code or circuit function code, labeled at a minimum of every three (3) inches. The identification of the wiring shall be referenced on a wiring diagram. All wires conform to SAEJ1127 (Battery Cable), SAEJ1128 (Low Tension Primary Cable), SAEJ1560 (Low Tension Thin Wall Primary Cable).
The covering of harnesses shall be moisture resistant loom with a minimum rating of 289° Fahrenheit and a flammability rating of VW-1 as defined in UL62. The covering of jacketed cable shall have a minimum rating of 289° Fahrenheit.
All circuits shall conform to SAEJ2202. All circuits must be provided with low voltage over current protective devices.
All exposed electrical connections will be coated with “Z-Guard” to prevent corrosion.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 51 of 140 PO00011799 - DIRECT BATTERY GROUNDING STRAP
Direct grounding straps shall be mounted to the following areas: frame to cab, frame to body and frame to pump enclosure.
All exposed electrical connections shall be coated with "Z-Guard 8000" to prevent corrosion.
PO00011800 - EMI/RFI PROTECTION
The apparatus shall incorporate the latest designs in the electrical system with state-of-the-art components to insure that radiated and conducted electromagnetic interference (EMI) and radio frequency interference (RFI) emissions are suppressed at the source.
EMI/RFI susceptibility is controlled by utilizing components that are fully protected and wiring that utilizes shielding and loop back grounds where required. The apparatus shall be bonded through wire braided ground straps. Relays and solenoids that are suspect to generating spurious electromagnetic radiation are diode protected to prevent transient voltage spikes.
In order to fully prevent the radio frequency interference, the purchaser may be requested to provide a listing of the type, power output, and frequencies of all radio and bio medical equipment that is proposed to be used on the apparatus.
PO00011805 - SEQUENCER
A sequencer shall be provided that automatically activates and deactivates vehicle loads in a preset sequence thereby protecting the alternator from power surges. This sequencer operation shall allow a gradual increase or decrease in alternator output, rather than loading or dumping the entire 12-volt load to prolong the life of the alternator.
Emergency light sequencing shall operate in conjunction with the emergency master light switch. When the emergency master switch is activated, the emergency lights shall be activated one by one at half second intervals. Sequenced emergency light switch indicators shall flash while waiting for activation.
When the emergency master switch is deactivated, the sequencer shall deactivate the warning light loads in the reverse order.
PO00010662 - MULTIPLEX CONTROL PUMP SHIFT SWITCH - MULTIPLEX The pump shift control shall be a Mil Spec toggle switch with mechanical detents mounted in a fully backlit panel that shall have indicators for “Pump Engage” and “Ok to Pump”.
The mode of the transfer case shall be controlled by remotely mounted air solenoids which shall be activated and monitored through the chassis control logic of the multiplex system.
PO00010255 - CLASS-1 ES-KEY MULTIPLEX ELECTRICAL SYSTEM A Class 1 ES-Key Electrical Management System shall be utilized on the chassis for all functions applicable.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 52 of 140 The system shall consist of the following components:
A Modem with a RS232 computer interface and standard telephone jack used to not only program the multiplex system but also serve as a factory direct gateway into the vehicle from any Class 1 multiplex authorized service facility.
A Universal System Manager (USM), which acts as the main controlling component of the multiplexing system shall be provided and factory programmed to DOT, NFPA, SAE, the manufacturer and Hemet Fire Department specifications. The programming shall be done by the manufacturer's engineering department.
The ES-Key system installation shall comply with SAE J 551 requirements regarding Electromagnetic and Radio Frequency interference (EMI, RFI), as well as utilize components and wiring practices that ensure the system is protected against corrosion, excessive temperatures, water, excessive physical, and vibration damage by any equipment installed on the vehicle at the time of delivery.
A series of Multiplexing Input/Output Modules shall be installed. The Input/Output modules shall permit the multiplexing system to reduce the amount of wiring and components used as compared to non-multiplexed apparatus. These modules shall vary in I/O configuration, be waterproof allowing installation outside of enclosed areas and shall possess individual output internal circuit protection. The modules shall also have three status indicators visible from a service persons vantage point that shall indicate the status of the module. In the event a load requires more than 7.5 AMPS of operating current, the module shall activate a simple relay circuit integral to any of the 3 dill box assemblies installed in the cab.
Diagnostic software shall be provided to download data from the on-board ES-KEY system. This software shall have the ability to view system input/output (I/O) information and include a connection from a computer to the vehicle.
PO00002776 - ADDITIONAL CLASS-1 ES-KEY ULTRAVIEW 780 DISPLAY, OS OF CAB An additional Class 1, UltraView, 700 display shall be provided and installed on the officer side of the cab.
The second display shall have the ability to perform and display all the same functions and information of the main display; located on the driver side of the cab.
PO00011807 - INTER-LOCK MODULE FOR MULTIPLEX SYSTEM
A multiplex module, which is the interface between the multiplexing system and the pump system shall be provided.
This module shall serve as the interface between the operator, engine, transmission and pumping system.
The module shall be installed in the driver's side dash. There shall be a pump diagnostic view in the UltraView screen that shall indicate to service personnel the interlock state of the apparatus.
In the event of a multiplexing error involving pump operation, an override can be activated to ensure reliable pumping operations at ALL times.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 53 of 140 The multiplex system shall be able to provide automatic and/or manual activation of engine “Fast Idle”, to maintain adequate alternator output and thus, chassis voltage.
There will be no exceptions.
PO00002792 - LEECE NEVILLE 320 AMP 4962PA -ALTERNATOR
The alternator shall be Leece Neville Model 4962PA, 320-amp, serpentine belt driven unit.
The installation shall include an integral, self-diagnostic regulator and rectifier for compact installation.
The alternator installation shall be designed to provide maximum output at engine idle speed to meet the minimum continuous electrical load of the apparatus as required.
PO00002815 - BATTERIES - SIX (6) EXIDE GROUP 31, 925CCA -31XHD Six (6) Exide # 31XHD, maintenance free batteries shall be provided.
Each battery shall be rated at 925 CCA and shall have a reserve capacity of 180 minutes.
Wiring for the batteries shall be 4/0 welding type dual path starting cables for SAEJ541.
PO00012455 - PREDATOR BATTERY STORAGE, STEEL, MFD, XMFD, LFD, XLFD Batteries shall be securely mounted in fixed 3/16” GR50 steel trays located on each side of the chassis frame.
Complete access shall be provided when the cab is fully tilted.
Batteries shall be mounted on non-corrosive matting material.
The battery tray shall be able to withstand a longitudinal acceleration of -46.5g at 0.246 seconds in accordance to SAE J211 standards using a channel frequency class 600 filter.
Testing shall be performed at and verified by a third-party testing and evaluation center.
PO00012453 - COLE HERSEE BATTERY JUMPER STUDS, DS BATTERY BOX A set of Cole Hersee battery jumper studs, model #46210-02 (red) and #46210-03 (black) shall be provided to allow the battery system to be jump started or charged from an external source.
The studs shall be located on the bottom of the battery box on the driver's side of the chassis.
Each stud shall be equipped with both a rubber protector cap and a 2” square non-conductive plate to prevent accidental shorting.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 54 of 140 PO00012461 - BATTERY DISCONNECT SWITCH, ALL UNITS
The chassis batteries shall be wired in parallel to a single 12-volt electrical system, controlled through a heavyduty master disconnect switch.
The master disconnect switch shall be located within easy access of the driver upon entering or exiting the cab.
PO00025504 - BLUE SEA 120 VOLT 20 AMP SURE EJECT FOR BATTERY CHARGER One (1) Blue Sea Sure Eject 120-volt, 20 amp shoreline disconnect shall be provided for the on board, 110 volt battery charging systems.
The disconnect shall be equipped with a NEMA 5-20 P male receptacle, which shall automatically eject the shoreline when the vehicle starter is energized.
The mating connector shall be included with the auto eject and shall be provided as loose equipment.
A label shall be provided indicating voltage and amperage ratings.
PO00025508 - RED COVER FOR BLUE SEA SURE EJECT RECEPTACLE The Blue Sea sure eject connection shall be equipped with a red cover.
PO00002839 - SHORELINE LOCATION - ADJACENT TO DRIVER'S DOOR The shoreline receptacle shall be located in the area directly adjacent to the driver's side cab door in a predetermined location by KME.
PO00022630 - SHORELINE RECEPTACLE LABEL - NFPA
A shoreline power receptacle information plate shall be permanently affixed at or near the power inlet. The plate shall indicate the following:
• Type of Line Voltage
• Current Rating in Amps Power Inlet Type (DC or AC).
PO00025505 - BLUE SEA #7532, 40 AMP, P12 BATTERY CHARGER A Blue Sea 7532, 40 Amp, P12 fully automatic battery charger shall be provided for maintaining the vehicle battery system. The exact mounting location of the battery charger shall be determined at the preconstruction meeting. A 7517 Battery Charger Display shall be provided and installed near the driver's seat in the cab.
Output current shall be 40 amperes @ 12-volt DC.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 55 of 140 PO00025600 - BLUE SEA #4365 ACCESSORY PANEL
A Blue Sea model 4365 accessory panel will be provided. The accessory panel shall include one (1) 12-volt power port, two (2) dual USB charging ports, along with a power switch with built in circuit breaker.
The accessory panel shall be mounted in the center dash panel. ***SPECIAL: SP00037859 - KUSSMAUL USB CHARGING PORTS IN REAR CREW AREA - IN FORWARD FACING
SEAT BASE
Two (2) Kussmaul USB charging ports shall be installed in the cab of the truck for fire department accessory devices.
Each port shall have two (2) USB connections and shall have a 5-volt, 4.2-amp max output.
The ports shall be located in the rear crew area, in the forward-facing seat base, between the seats.
PO00010730 - POWER AND GROUND STUD FOR ACCESSORIES IN DASH One (1) dedicated circuit; 12-volt, 40 Amp, power and ground on 3/8 stud and fused at battery shall be provided in the cab dash.
The circuit shall be for future installation of radios or accessories. ***SPECIAL: SP00037861 - BLUE SEA FUSE BLOCKS - 6 CIRCUIT Two (2) Blue Sea 5025B, 6 circuit fuse blocks, shall be installed, one (1) behind the drivers seat, and one (1) under the forward facing center crew seats. The fuse blocks shall have a maximum amperage of 60 Amps per block and 30 Amps per circuit.
PO00012534 - BLUE SEA FUSE BLOCK - 12 CIRCUIT BEHIND OFFICER SEAT A Blue Sea 5026B, 12 circuit fuse block, shall be installed behind the officers seat.
This block has a maximum amperage of 60 amps per block and 30 amps per circuit and shall be connected to battery power.
PO00010731 - MULTI - USE POWER POINT - REAR OF ENGINE ENCLOSURE A Mobile Vision (Magnadyne DVU-3G2) multi-use power point with built in two (2) USB ports, and two (2) 12- volt sockets shall be installed in the rear of the cab on the back of the engine enclosure.
This will be capable of supplying the USB ports with up to three (3) amps and have a 15-amp fuse for overall protection.
16.H
City of Hemet
2023 Type 1 ‘Severe Service’ Pumper
MANUFACTURERS DETAILED SPECIFICATIONS
Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 56 of 140 PO00010732 - IGNITION STUD - REAR CREW AREA
An ignition stud shall be installed in the rear crew area for items needing an ignition circuit ( ie. mobile radio).
This stud has a maximum amperage of 20 Amps.
***SPECIAL: SP00017065 - WELDON #8080-8001-13 WHITE/RED LED INTERIOR LIGHTS (4) Four (4) Akron 8080-8001-13 interior LED combination red/white dome lights shall be furnished in the cab, with two (2) in the forward section and two (2) in the rear crew section.
Each dome light shall have an integral selector switch.
Each dome light shall also activate when the respective, adjacent cab door is opened.
Each dome light shall default to RED when activated.
PO00002907 - INNER CAB DOOR FLASHERS (LED), WELDON DOOR STRIP LIGHT One (1) Weldon, 16" LED door warning lamp shall be provided on the inside door panel of each cab door.
The light shall be mounted on the door's lower scuff plate and shall be activated when the respective door is opened.
Each light shall be furnished with a clear lens and amber LEDs. ***SPECIAL: SP00008406 - SUNNEX MAP LIGHT AT OFFICER SIDE Sunnex model # SL9-200B10L LED light designed for direct connection shall be furnished and located on the officer's side of the center air plenum above the officer's left shoulder. ***SPECIAL: SP00008408 - SUNNEX MAP LIGHT AT DRIVER SIDE Sunnex model # SL9-200B10L 12-volt - LED light designed for direct connection shall be furnished and located on the driver side of the center air plenum above the driver's right shoulder. ***SPECIAL: SP00020012 - ENGINE COMPARTMENT WORK LIGHTS - TECNIQ LED Four (4) Tecniq model #E18 LED lights shall be provided inside the engine enclosure that will provide 800 lumens each. Two (2) shall be mounted close to the radiator, and two (2) shall be mounted above the transmission bell housing. Each light shall have their own independent switch incorporated into the light head.
For Clarification: The engine enclosure lights shall turn on/off with the cab tilt.