2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 57 of 140 PO00011695 - DASH & CENTER CONSOLE - 100" PREDATOR SS
Where standard features are controlled through physical switches they will be indicated as such in the appropriate part of this specification. All optional features that are controllable from the cab will be controllable through the display screen.

The dash consoles shall be custom formed overlaid aluminum housings to create an ergonomically designed interior that will be user friendly and functional for the driver and officer.

The cab instruments and controls will be labeled with international symbols and located in the following zones:
• Driver Gauge Left: Located to the left of the instrument panel, this zone houses the ignition, engine start, and fast idle switches.
• Driver Gauge Right: Located to the right of the instrument panel, this zone houses power take-off and ladder power switches when those features are specified. • Driver Knee Left: Located at the driver’s left knee area, this zone is the standard location for pump controls, and for the Engine Emergency Shutdown when specified.
• Driver Knee Right: Located at the driver’s right knee area, this zone houses optional chassis related switches such as the Fuel Priming Pump, Engine Fan Override, and ATC Disable. • Driver Lower Wing: Located on the engine tunnel and angled toward the driver, this zone houses the majority of the controls that the driver may need to access while operating. Within the easiest reach of the driver are the park brake, transmission shift, Vehicle Information Display, and any optional retarder controls. Standard switching in this zone includes power window controls, hazard flasher, headlights, marker lights, and mirror adjustment. Also located in this zone will be switching for any optional features that are more likely to be used while driving such as auxiliary brakes, siren brake, drive axle locks, and automatic tire chains.
• Center Lower: Located on the engine tunnel between the driver and officer and parallel to the cab front, this zone houses the standard 12-volt sockets and USB chargers. It will also house any optional communications devices that are more likely to be accessed while driving such as an arrowhead controller or a stereo radio.
• Driver Overhead: Located in the overhead console directly above and facing the driver, this zone houses tactile switches (when specified) for control of emergency devices such as warning lights, scene lights, dump chute valves, and other emergency related items. If not specified these controls are available through the Vehicle Information Center.
• Driver Overhead Wing: Located in the overhead console and angled toward the driver, this zone houses the heating and air conditioning tactile switches provided as standard. • Center Overhead: Located overhead between the driver and officer and parallel to the cab front, this zone houses any communications devices such as siren heads or two-way radios that cannot be fit in the Officer Lower Wing: Located on the engine tunnel and angled toward the officer, this zone houses optional feature switching as specified for control by the officer.
• Officer Overhead Wing: Located in the overhead console and angled toward the officer, this zone is houses optional switching or gauges that cannot be located in other zones and that is intended solely for use by the officer.
• Officer Overhead: Located in the overhead console directly above and facing the officer, this zone houses optional larger communications equipment that cannot be located in other zones, and that is practical for use solely by the officer.

Page 225 of 508 ends

16.H

Page 1289 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 58 of 140 Exact locations of each switch or control will be dictated by the Dash Layout document created during the design process and will adhere to these guidelines unless otherwise specified.

PO00024139 - CAB DASH PANELS
The apparatus cab shall be outfitted with backlit gradient dash and overhead panels. These gradient panels shall be utilized across the entire front of the cab dash and include the instrument cluster and brow panels.

The panels shall be constructed from 3mm aluminum composite panels with second surface screen printed 15 mil Bayfol UV-1 polycarbonate graphic overlays, to provide scratch and UV protection. A carbon-graphite shaded graphic overlay shall be provided.

PO00012297 - CONTROL SWITCHING THROUGH MULTIPLEX TOU
Switching for the emergency and auxiliary systems shall be performed through the multiplex control screen.

Switching shall programmed through various menus that are accessible from the display buttons.

PO00010735 - HOSE BED WORK LIGHT - SWITCH
The hose bed work light shall have a protected 12-volt switch at the rear body panel.

The switch will be labeled "HOSE BED WORK LIGHTS."
PO00003388 - CONTROL SWITCHES IN CAB FOR REAR OF CAB LIGHTS Controls shall be provided in the cab control system (or optional mechanical switch) to turn the rear of cab lights on and off.

PO00003389 - CONTROL SWITCHES ON PUMP PANEL FOR REAR OF CAB LIGHTS Two (2) switches shall be provided on the pump panel to turn the rear of cab lights on and off.

One (1) switch shall control the driver side light and one (1) switch shall control the officer side light.

PO00003391 - CONTROL SWITCHES IN CAB FOR LIGHT ABOVE WINDSHIELD - HIVIZ Controls shall be provided in the cab control system (or optional mechanical switch) to activate the HiViz, FireTech, LED brow light.

PO00003232 - CONTROL SWITCHES IN CAB FOR BEHIND FRONT CAB DOOR LIGHTS Controls shall be provided in the cab control system (or option mechanical switch) to turn the lights at the cab doors on and off.

Page 226 of 508 ends

16.H

Page 1290 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 59 of 140 PO00003234 - CONTROL SWITCH IN CAB FOR 12 V REAR OF BODY SCENE LIGHTS Controls shall be provided in the cab control system (or optional mechanical switch) to turn the rear of body lights on and off.

PO00003235 - CONTROL SWITCH ON PUMP PANEL FOR 12 V REAR OF BODY SCENE LIGHTS A switch shall be provided on the pump panel to turn the rear of body lights on and off.

PO00011697 - DRIVER'S DASHBOARD PANEL, 100" PREDATOR SS The main instrument panel shall be centered in front of the driver and shall be mechanically fastened to the main dash assembly. The panel shall contain the primary gauges, an instrument warning light cluster and the ignition and engine start switches.

Each gauge shall be designed with an integral red warning light with a pre-programmed warning point. Gauges monitoring drive-train component status shall be of the direct data bus type capable of displaying information broadcast on the J 1939 datalink.

Each gauge warning indicator shall be capable of activating an audible alarm inside the dashboard.

Additional auxiliary control switches and instruments (if applicable) shall be located within the center or overhead panel located near the driver's position.

PO00022740 - DRIVER DASH LCD VIRTUAL DISPLAY
The main instrument panel shall be centered in front of the driver and shall have a hinged bottom with two ¼ turn latches at the top. The driver panel and all other cab interior dash and overhead panels will be an antiglare surface.

Contained within this panel will be virtual driver display via a 12.3” LCD screen including but not limited to displaying all gauges and instrument warning light cluster functions The upper left side of the driver dash panel shall also include an ignition-on switch, fast idle switch and a round engine start button which shall include a lighted indicator on the perimeter to light up when engine is ready to start and turning off when the engine is started.

The driver LCD virtual display shall include:
• 12.3” Color TFT Display
• Stand Alone Architecture
• Automatic Adjustment for Light Conditions
• 3 x BNC Analog Video Input
• Fully Programmable Features w/Graphical HMI:CGI Studio • Two Year Warranty
• The primary gauge display shall consist of:
• Vehicle speedometer, (0-80 mph)
• Engine tachometer, (0-3000 rpm)

Page 227 of 508 ends

16.H

Page 1291 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 60 of 140 • Engine oil pressure, (0-100 psi); low oil warning
• Engine coolant temperature (100-250 °F); high engine temp warning • Transmission oil temperature (100-350 °F); high transmission fluid temp warning • Vehicle battery voltage (0-18 VDC); low voltage warning • Front air system gauge (0-150 psi); low air pressure warning at 65 psi • Rear air system gauge (0-150 psi); low air pressure warning at 65 psi • Fuel level (E - 1/2 - F); low fuel level warning
• Diesel Exhaust Fluid (DEF) Level (E-1/2-F)
• Air cleaner restriction gauge (0-40), warning at 25"
• Engine hours as maintained by the engine ECU
Additional auxiliary control switches and instruments (if applicable) shall be located within the dash panel and overhead panel located near the driver's position.

INDICATOR CLUSTER
This display, also contained in the Driver Dash Virtual Display Module, includes the system control unit that collects data from the vehicle data bus (J1939), analog sensors, and switches throughout the vehicle. This data shall be presented using simulated gauges and telltales.

On the Road displays include:
• Odometer, trip information, fuel economy information; all gauge data, and virtually any other data available on the vehicle that the display has access to, either through the data bus or via analog inputs.

The displays that can be accessed when the parking brake is set include:
• "Right And Left Directional" arrows (green in color)
• "Hi Beam" indicator (blue in color)
• "Battery ON" indicator (green in color)
• "Parking Brake ON" indicator (red in color)
• "Check Transmission" indicator (amber in color)
• "Cab Not Latched" indicator (red in color)
• "Stop Engine" indicator (red in color)
• "Check Engine" indicator (amber in color)
• "ABS Warning" indicator (yellow in color)
• "Low Coolant Level" (yellow in color)
• "Water In Fuel" indicator (amber in color)
• "DPF Regeneration" (amber in color)
• "Exhaust High Temperature" (amber in color)
• "Engine Diagnostic Fault" (amber in color)
• "Retarder On" (green in color)
Listed below are indicators that may be included, depending upon the vehicle configuration:
• "Wait To Start" indicator (amber in color)
• "Exhaust System Fault" (amber in color)

Page 228 of 508 ends

16.H

Page 1292 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 61 of 140 • "Topps System Fault" (amber in color)
• "PTO Engaged" (green in color)
• "Ok to Pump" (green in color)
• "Auto Traction Control" (amber in color)
PO00010551 - FAST IDLE ON DASH FOR ALL ELECTRONIC ENGINES A fast idle for the electronic controlled engine shall be provided.

The fast idle shall be controlled by an ON/OFF switch on the left side of the main gauge panel.

An electronic interlock system shall prevent the fast idle from operating unless the transmission is in "Neutral" and the parking brake is fully engaged.

If the fast idle control is used in conjunction with a specified engine/transmission driven component or accessory, the fast idle control shall be properly interlocked with the engagement of the specified component or accessory.

PO00010697 - ENGINE COMPRESSION BRAKE CONTROLS
Engine brake controls shall be provided on the dash within easy reach of the driver.

PO00002774 - CLASS-1 ES-KEY ULTRAVIEW 780 DISPLAY
A 7-inch full color display shall located on the driver's lower wing panel. The display shall provide key information and control within easy sight and reach.

The screen shall be programmed with the following features:
• Chassis Instrument Display
• Back-up camera
• Seat Occupant Display
• Compartment open display
• HVAC Controls
• Power Mirror Controls
• DPF Filter Regeneration Controls
• Warning light controls
• Scene light controls
• Horn selector switch options
• Gauge back-light dimming
• Rocker switch back-light dimming
• Display screen dimming with day/night feature
• Multiplex system diagnostics
• Generator Controls

Page 229 of 508 ends

16.H

Page 1293 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 62 of 140 PO00025678 - PUMP SHIFT CONTROL ON DRIVER LOWER LEFT KNEE PANEL The pump shift control and pump engaged indicator light shall be mounted in the driver's lower left knee panel.

PO00025601 - ASA VOYAGER CAMERA - REAR CAMERA
An ASA Voyager rear vision camera model # VCMS155 shall be provided to allow the driver to visually see the rear of the apparatus while in the cab.

The rear vision camera shall be mounted on the rear of the apparatus and shall be wired to automatically activate when the chassis transmission is placed in reverse. ***SHOP NOTE: SR00152729 - RECESS MOUNTED REAR CAMERA
The specified rear camera shall be recess mounted in the center of the rear sheet of the body within the specified painted pocket.

PO00025602 - ASA VOYAGER CAMERA - OFFICER SIDE CAMERA
An ASA Voyager rear vision camera model # VCMS50 shall be provided to allow the driver to visually see the officer side of the apparatus while in the cab.

The side vision camera shall be mounted on the officer side of the cab and shall be wired to automatically activate when the right turn signal is activated unless the chassis is placed in reverse in which case the backup camera will activate.

PO00025603 - REAR VISION CAMERA DISPLAYED IN MULTIPLEX SCREEN The video output from the camera(s) shall be displayed on the Ultraview, display panel.

PO00026376 - REAR VISION CAMERA DISPLAYED IN OFFICER MULTIPLEX SCREEN The video output from the camera(s) shall be displayed on the officer side multiplex display panel.

PO00010733 - CUST PUMP/TANK/RES CHASSIS LED MARKER LIGHTS

DOT MARKER LIGHTS AND REFLECTORS
PO00003068 - CAB STEP LIGHTS, TECNIQ EON 3 LED, ALL DEVICES Polished, stainless-steel, Tecniq Eon, 3-LED, horizontal surface mounted chassis step lights shall be provided and controlled with marker light actuation.

Step lights shall be located to properly illuminate all chassis access steps and walkway areas and shall include a mounting gasket to provide a watertight seal.

Page 230 of 508 ends

16.H

Page 1294 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 63 of 140 PO00002995 - OPTRONICS LED MARKER LIGHTS @ FRONT ROOF EDGE OF CAB - HIVIZ Two (2) amber DOT approved, Optronics MCL13 Light Emitting Diode (LED) cab marker lamps shall mounted on the top, front outside edge of the cab roof.

PO00002984 - DUAL MODULE W/ WHELEN C6 LED TURN SIGNAL & REQ WARN LIGHT Two (2) Whelen C6T, arrow shaped, amber LED turn signals shall be provided, putting one (1) on each side of the dual light module above the headlights.

The NFPA required, Zone "A" lower warning lights shall be incorporated into each side dual light module noted above.

PO00004075 - ALTERNATE FLASHING HEADLIGHT SYSTEM (WIG-WAGS) An alternating flashing wig-wag system, wired to the apparatus headlights, shall be installed.

The wig-wag system shall be individually switched at the master light console.

The alternating flashing system shall be automatically disabled during the "Blocking Right of Way" mode.

PO00024477 - DUAL HEADLIGHTS LED FIRETECH HIVIZ
Two (2) dual, Firetech HiViz LED headlight modules with a bright finish bezel shall be furnished, one (1) each side, on the front of the cab. Each head light module shall incorporate an individual LED low beam and a LED high beam headlight. High beam actuation shall be controlled on the turn signal lever.

PO00010729 - DAYTIME RUNNING LIGHTS
The chassis head lights shall have integrated circuitry to actuate the low beam headlights whenever the chassis engine is running.

The daytime running lights shall be interlocked with the parking brake.

PO00003371 - HIVIZ FIRETECH 65" BROW LIGHT W/ IML, 255W12V LED, (1) ABOVE WINDSHIELD One (1) HiViz LEDs "FireTech" Scene light, model FT-B-65-ML3-W shall be provided.

The light instrument shall be low in profile with a mounting bracket allowing installation at the top edge of the windshield.

The housing shall be made of a extruded 6061 aluminum; approximately 65" wide and less than 3" tall.

The scene light shall have 53 LEDs divided amongst 4 independent circuits: circuit one featuring 6x 5w LEDs passing light through a 10 degree optic, circuit two featuring 18x 5w LEDs passing light through a 25-40 degree "flood" range, and circuit three featuring 24x 5w LEDs passing light through a 60-90 degree "scene" optic.

Page 231 of 508 ends

16.H

Page 1295 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 64 of 140 Circuit four shall consist of 3 amber colored diodes that act as SAE-J2042 compliant identification lamps.

The circuitry shall feature a PWM LED driver with an onboard electronic thermal manager.

Additionally, the bar shall meet CISPR25 EMI requirements.

The light shall operate on 12v DC, generate 25,143 lumens and draw 21 amps.

The light shall be adjustable vertically up to 15 degrees.

Mounting shall be possible in any direction while still meeting NFPA 1901 compliance requirements.

The housing color shall be White. The light shall feature a limited Lifetime warranty.

PO00003383 - WHELEN LED PFP2P 150W TELESCOPING W/POLES, 12V - REAR OF CAB Two (2) Whelen, model #PFP2P, 150-watt, 12-volt, LED flood lights shall be installed, one (1) on each side, on the rear of the cab, each using a Whelen, side mount, telescoping pole.

Each lamp head shall draw 12 amps and generate 14,000 lumens.

Each light shall be switched at the light head.

PO00003396 - WIRE UPGRADE FOR 12V HIGH AMP LIGHT - (1) BROW LIGHT PO00003399 - WIRE UPGRADE FOR 12V HIGH AMP LIGHTS - REAR OF CAB PO00010755 - NFPA COMPLIANT WARNING LIGHT PACKAGE
The following warning light package shall include all of the minimum warning light and actuation requirements for the current revision of the NFPA 1901 Fire Apparatus Standard.

The lighting as specified shall meet the requirements for both "Clearing Right of Way" and "Blocking Right of Way" which includes disabling all white warning lights when the apparatus is in "Blocking Right of Way" mode.

PO00010757 - WARNING LIGHT FLASH PATTERN - NFPA FLASH PATTERN All of the perimeter warning lights shall be set to a default NFPA compliant flash pattern as provided by the light manufacturer.

PO00010756 - LIGHT PACKAGE ACTUATION/CONTROLS
The entire warning light package shall be actuated with a single warning light switch located on the cab switch panel. The wiring for the warning light package shall engage all of the lights required for "Clearing Right of Way" mode when the vehicle parking brake is not engaged. An automatic control system shall be provided to switch the warning lights to the "Blocking Right of Way" mode when the vehicle parking brake is engaged.

Page 232 of 508 ends

16.H

Page 1296 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 65 of 140 PO00010759 - LIGHT PACKAGE NFPA CERTIFICATION
The warning light system(s) specified above shall not exceed a combined total amperage draw of 45 AMPS with all lights activated in either the "Clearing Right of Way" or the "Blocking Right of Way" The warning light system(s) shall be certified by the light system manufacturer(s), to meet all of the requirements in the current revision of the NFPA 1901 Fire Apparatus Standard as noted in the General Requirements section of these specifications.

The NFPA required "Certificate of Compliance" shall be provided with the completed apparatus.

Any large truck as defined by NFPA shall have the lower zone warning lights mounted no higher than 62" to the optical center of the warning light from ground level. {No Exceptions} PO00003606 - A-UPPER, WHELEN LED F4N7VLED, FREEDOM SERIES IV 72" LIGHT BAR A Whelen # F4N7VLED "Edge Freedom Series IV", 72" LED cab roof warning light bar shall be furnished and rigidly mounted on top of the cab roof.

The light bar shall be equipped with the following:
• Clear Lenses
• Four Corner Red Linear LEDs
• Two Red Forward-Facing Linear LEDs
• Two White Forward-Facing Linear LEDs. If equipped, the forward-facing white lights shall be automatically disabled for the "Blocking Right of Way" mode.

PO00004115 - ZONE A WARNING LIGHTS - STEADY BURN IN LIGHTBAR PO00023615 - LED ALLEY LIGHTS
The Freedom lightbar shall be equipped with # FXALF1D led alley lights.

PO00023616 - #795H 3M LED EMITTER
The Freedom lightbar shall be equipped with a # 795H Low Profile LED Opticom emitter. The Opticom emitter shall be disabled automatically for the "Blocking Right of Way" mode.

PO00023618 - PAIR OF RED LED’S
The Freedom lightbar shall be equipped with the noted quantity pair(s) of # F4DLR red LED warning lights.

PO00003635 - C-UPPER, WHELEN LED MCFLED2R, MICRO FREEDOM LIGHT BARS Two (2) Whelen, MCFLED2R, "Micro Freedom", mini warning, light bars shall be furnished and rigidly mounted so that each light faces the rear, one (1) on each side at the rear of the body.

Page 233 of 508 ends

16.H

Page 1297 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 66 of 140 ***SHOP NOTE: SR00153139 - C-UPPER WARNING LIGHT MOUNTING The upper zone C mini bars will be mounted directly to the compartment caps with the closed portion of the "V" to the rear.

PO00024573 - UPPER ZONE C WARNING LIGHT LENS - RED
The upper zone C warning lights shall include red LEDs and a red lens if available from the manufacturer. If a red lens is unavailable, a clear lens shall be included.

PO00003662 - B/D-UPPER FRONT, COVERED BY LIGHTS IN ZONE A-UPPER The lighting requirement for this area is covered by the lights noted in Zone "A" - Upper.

PO00003649 - B/D-UPPER REAR, COVERED BY LIGHTS IN ZONE C-UPPER The lighting requirement for this area is covered by the lights noted in Zone "C" - Upper.

PO00012072 - A-LOWER FRONT MOUNTING, CUSTOM CHASSIS
The lower Zone A warning lights shall be mounted in the custom chassis headlight bezels.

PO00003868 - A-LOWER FRONT, WHELEN C6 SUPER LEDS
Two (2) Whelen C6 super LED light heads shall be provided and installed one (1) each side.

PO00024579 - LOWER ZONE A WARNING LIGHT LENS - RED
The lower zone A warning lights shall include red LEDs and a red lens if available from the manufacturer. If a red lens is unavailable, a clear lens shall be included.

PO00024599 - LOWER ZONE A WARNING LIGHT BEZEL - CHROME
The lower zone A warning lights shall include red LEDs and a chrome bezel if available from the manufacturer.

If a chrome bezel is unavailable, a black bezel shall be included.

PO00003878 - C-LOWER REAR, WHELEN C6 SUPER LEDS
Two (2) Whelen, C6, super LED light heads shall be provided and installed one (1) each side directly below the DOT stop, tail, turn and backup lights.

PO00024581 - LOWER ZONE C WARNING LIGHT LENS - RED
The lower zone C warning lights shall include red LEDs and a red lens if available from the manufacturer. If a red lens is unavailable, a clear lens shall be included.

Page 234 of 508 ends

16.H

Page 1298 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 67 of 140 PO00012074 - B/D-LOWER FRONT MOUNTING, CUSTOM CHASSIS
The lower Zone B D warning lights shall be mounted on the sides of the custom chassis front bumper.

PO00003892 - B/D-LOWER FRONT, WHELEN C6 SUPER LEDS
Two (2) Whelen, C6 super LED light heads shall be provided and installed with one (1) on each side.

PO00024583 - LOWER ZONE B/D FRONT WARNING LIGHT LENS - RED The lower zone B/D front warning lights shall include red LEDs and a red lens if available from the manufacturer.

If a red lens is unavailable, a clear lens shall be included.

PO00024603 - LOWER ZONE B/D FRONT WARNING LIGHT BEZEL - CHROME The lower zone B/D front warning lights shall include a chrome bezel if available from the manufacturer. If a chrome bezel is unavailable, a black bezel shall be included.

PO00003903 - B/D-LOWER MID, WHELEN C6 SUPER LEDS
Two (2) Whelen, C6 super LED light heads shall be provided and installed with one (1) on each side.

PO00024585 - LOWER ZONE B/D MID WARNING LIGHT LENS - RED The lower zone B/D mid warning lights shall include red LEDs and a red lens if available from the manufacturer.

If a red lens is unavailable, a clear lens shall be included.

PO00024605 - LOWER ZONE B/D MID WARNING LIGHT BEZEL - CHROME The lower zone B/D mid warning lights shall include a chrome bezel if available from the manufacturer. If a chrome bezel is unavailable, a black bezel shall be included.

PO00003925 - B/D-LOWER REAR, WHELEN C6 SUPER LEDS
Two (2) Whelen C6 super LED light heads shall be provided and installed with one (1) on each side.

PO00024587 - LOWER ZONE B/D REAR WARNING LIGHT LENS - RED The lower zone B/D rear warning lights shall include red LEDs and a red lens if available from the manufacturer.

If a red lens is unavailable, a clear lens shall be included.

PO00024607 - LOWER ZONE B/D REAR WARNING LIGHT BEZEL - CHROME The lower zone B/D rear warning lights shall include a chrome bezel if available from the manufacturer. If a chrome bezel is unavailable, a black bezel shall be included.

Page 235 of 508 ends

16.H

Page 1299 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 68 of 140 ***SPECIAL: SP00037873 - WHELEN MICRON "TRAFFIC ADVISOR" LIGHT RECESSED AT REAR OF BODY A traffic directing light shall be provided at the rear of the apparatus as high as practical. The traffic advisor shall have six (6) Micron series amber LED warning lights.

The traffic advisor shall be arranged with two (2) groups of three (3) rear directing light modules utilizing Whelen MICRON series Amber Super-LED lights shall be installed on the rear of the unit. This shall be a split module design to provide the RDL function for an apparatus body that has an open rear center area. The modules shall be mounted at the top of the left and right side as high as possible. The lights shall be mounted within a recessed pocket along with the backup camera. The pocket shall be painted black.

The traffic advisor shall be programmed and controlled through the multiplex screen to eliminate the need for a separate controller. One Whelen SL flasher preprogrammed for a TA flasher will be provided.

The rear directional light shall be wired through the load management system of the unit.

Program the traffic advisor to operate on random flash pattern when emergency master is turned on. The traffic advisor multiplex control screen will be used to override the random flash (turn off or change pattern) when the E-master is engaged, or independently control the lights when the E-master is not engaged.

PO00003271 - NFPA (4) AMDOR H2O LED GROUND LIGHTS, BELOW CAB DOORS One (1) Amdor Luma Bar, H2O, LED 20" ground light shall be provided under each side cab door entrance step, four (4) total.

Each light shall illuminate an area at a minimum 30" outward from the edge of the vehicle.

PO00003274 - GROUND LIGHTS, 2 LED BELOW PUMP PANEL RUNNING BOARD - H2O One (1) Amdor Luma Bar, H2O, LED 20" ground light shall be provided under each side pump panel running board, two (2).

PO00003277 - GROUND LIGHTS, 2 LED AT REAR BODY CORNERS - H2O One (1) Amdor Luma Bar, H2O, LED 20" ground light shall be provided under each rear body corner, two (2) total.

PO00009695 - CAB AND BODY GROUND LIGHTS ACTIVATE WITH PARKING BRAKE The cab and body ground lights shall activate by engaging the parking brake.

PO00009696 - CAB AND BODY GROUND LIGHTS - SWITCH @ PUMP PANEL The cab and body ground lights shall be equipped with an activation switch on the pump operator's panel.

Page 236 of 508 ends

16.H

Page 1300 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 69 of 140 PO00011802 - CHASSIS DIAGNOSTICS SYSTEM
Diagnostic ports shall be accessible while standing on the ground and located inside the driver's side door left of the steering column. The diagnostic panel shall allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches shall allow engine and ABS systems to provide blink codes should a problem exist.

The diagnostic system shall include the following:
• A single port to monitor the engine, transmission and ABS system and diagnostics of the roll sensor (if applicable)
• Engine diagnostic switch (blink codes)
• ABS diagnostic switch (blink codes)
• Allison Transmission Codes (through touch pad shifter) PO00011803 - VOLTAGE MONITORING SYSTEM - 12-volt
A voltage monitoring system shall be provided to indicate the status of the battery system connected to the vehicle's electrical load. The system shall provide visual and audible warning when the system voltage is below or above optimum levels.

The alarm shall activate if the system falls below 11.8 volts DC for more than two (2) minutes.

PO00011804 - INDICATOR LIGHT AND ALARM PROVE-OUT SYSTEM A system shall be provided which automatically tests basic indicator lights and alarms located on the cab instrument panel.

PO00011806 - ELECTRICAL HARNESS INSTALLATION - 12-volt
To ensure dependability, all 12-volt wiring harnesses installed by the manufacturer shall conform to the following specifications:
• SAE J 1128 - Low tension primary cable
• SAE J 1292 - Automobile, truck, truck-tractor, trailer and motor coach wiring • SAE J 163 - Low tension wiring and cable terminals and splice clips • SAE J 2202 - Heavy duty wiring systems for on-highway trucks • NFPA 1901 - Standard for automotive fire apparatus
• FMVSS 302 - Flammability of interior materials for passenger cars, multipurpose passenger vehicles, trucks and buses
• SAE J 1939 - Serial communications protocol
• SAE J 2030 - Heavy-duty electrical connector performance standard • SAE J 2223 - Connections for on board vehicle electrical wiring harnesses • NEC - National Electrical Code
• SAE J 561 - Electrical terminals - Eyelet and spade type • SAE J 928 - Electrical terminals - Pin and receptacle type A.

Page 237 of 508 ends

16.H

Page 1301 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 70 of 140 For increased reliability and harness integrity, harnesses shall be routed throughout the cab and chassis in a manner which allows the harnessing to be laid into its mounting location. Routing of harnessing which requires pulling of wires through tubes is never allowed at the manufacturer.

Wiring shall be run in loom or conduit where exposed and have grommets or other edge protection where wires pass through metal. Wire colors shall be integral to each wire insulator and run the entire length of each wire. Harnessing containing multiple wires and uses a single wire color for all wires shall not be allowed.

Function and number codes shall be continuously imprinted on all wiring harness conductors at 3.00" intervals.

All wiring installed between the cab and into doors shall be protected by a wire conduit to protect the wiring.

Exterior exposed wire connectors shall be positive locking, and environmentally sealed to withstand elements such as temperature extremes, moisture and automotive fluids. Electrical wiring and equipment shall be installed utilizing the following guidelines:
• All holes made in the roof shall be caulked with silicon. {No Exceptions} Large fender washers, liberally caulked, shall be used when fastening equipment to the underside of the cab roof. • Any electrical component that is installed in an exposed area shall be mounted in a manner that shall not allow moisture to accumulate in it. Exposed area shall be defined as any location outside of the cab or body.
• For low cost of ownership, electrical components designed to be removed for maintenance shall be quickly accessible. For ease of use, a coil of wire shall be provided behind the appliance to allow them to be pulled away from the mounting area for inspection and service work. • Corrosion preventative compound shall be applied to non-waterproof electrical connectors located outside of the cab or body. All non-waterproof connections shall require this compound in the plug to prevent corrosion and for easy separation of the plug.
• Any lights containing non-waterproof sockets in a weather-exposed area shall have corrosion preventative compound added to the socket terminal area.
• All electrical terminals in exposed areas shall have protective coating applied completely over the metal portion of the terminal.
• Rubber coated metal clamps shall be used to support wire harnessing and battery cables routed along the chassis frame rails.
• Heat shields shall be used to protect harnessing in areas where high temperatures exist. Harnessing passing near the engine exhaust shall be protected by a heat shield. • Cab and crew cab harnessing shall not be routed through enclosed metal tubing. Dedicated wire routing channels shall be used to protect harnessing therefore improving the overall integrity of the vehicle electrical system. The design of the cab shall allow for easy routing of additional wiring and easy access to existing wiring.
• All standard wiring entering or exiting the cab shall be routed through sealed bulkhead connectors to protect against water intrusion into the cab.

All 12-volt battery cables and battery cable harnessing installed by the apparatus manufacturer shall conform to the following requirements:
• SAE J 1127 - Battery Cable
• SAE J 561 - Electrical terminals, eyelets and spade type • SAE J 562 - Nonmetallic loom
• SAE J 836 A - Automotive metallurgical joining
• SAE J 1292 - Automotive truck, truck-tractor, trailer and motor coach wiring

Page 238 of 508 ends

16.H

Page 1302 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 71 of 140 • NFPA 1901 - Standard for automotive fire apparatus.

Battery cables and battery cable harnessing shall be installed utilizing the following guidelines:
• Splices shall not be allowed on battery cables or battery cable harnesses. • For ease of identification and simplified use, battery cables shall be color coded. All positive battery cables shall be marked red in color. All negative battery cables shall be black in color. • For ease of identification, all positive battery cable isolated studs throughout the cab and chassis shall be red in color.
• For increased reliability and reduced maintenance, all electrical buss bars located on the exterior of the apparatus shall be coated to prevent corrosion.
• An operational test shall be conducted to ensure that any equipment that is permanently attached to the electrical system is properly connected and in working order.

PO00011821 - BODY ELECTRICAL SYSTEM
All electrical lines in the body shall be protected by automatic circuit breakers, conveniently located to permit ease of service.

Flashers, heavy solenoids and other major electrical controls shall be located in a central area near the circuit breakers.

All lines shall be color and function coded every 3", easy to identify, oversized for the intended loads and installed in accordance with a detailed diagram.

A complete wiring diagram shall be supplied with the apparatus.

Wiring shall be carefully protected from weather elements and snagging. Heavy duty loom shall be used for the entire length.

Grommets shall be utilized where wiring passes through panels.

In order to minimize the risk of heat damage, wires run in the engine compartment area shall be carefully installed and suitably protected by the installation of heat resistant shielded loom.

All electrical equipment shall be installed to conform to the latest federal standards as outlined in NFPA 1901.

PO00010753 - BODY ELECTRICAL HARNESS - ES-KEY
PO00010754 - POWER DISTRIBUTION MODULES FOR CLASS ONE ES-KEY SYSTEM Class 1 Power distribution modules shall be provided in strategic areas of the chassis to allow body harnesses to interface to multiplex system.

The Remote Power Modules (RPM) provide a method of controlling loads on the vehicle, outside the cab, without running individual wires from each switch to the load.

Page 239 of 508 ends

16.H

Page 1303 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 72 of 140 This electronic module distributes and controls power to various devices on the vehicle as commanded by the control system inside the cab.

The RPM is connected to the Electrical System Controller via the J1939 datalink.

Each module receives power from a power cable, protected by a fusible link to the main battery circuit.

The power distribution modules shall be mounted in a location to provide complete access for service or trouble shooting.

PO00026555 - BLUE SEA FUSE BLOCK IN BODY COMPARTMENT - BATTERY POWER The Blue Sea fuse block(s) installed in the body shall have the power source connected directly to battery.

PO00025545 - BLUE SEA FUSE BLOCK - 6 CIRCUIT REARWARD WALL R5 A Blue Sea 5025B, 6 circuit fuse block, shall be installed on the upper rearward wall of the body R5 compartment interior.

This block has a maximum amperage of 60 Amps per block and 30 Amps per circuit.

PO00012441 - DOOR OPEN INDICATOR W/ INTEGRAL AUDIBLE ALARM An indicator light with an audible alarm, shall be functionally located in the cab to signal when an unsafe condition is present such as an open cab door or body compartment door, an extended ladder rack, a deployed stabilizer, an extended light tower or any other device which is opened, extended or deployed which may cause damage to the apparatus if it is moved.

This light shall be activated through the parking brake switch to signal when the parking brake is released. ***SPECIAL: SP00001513 - MOMENTARY ALARM SILENCE SWITCH A switch shall be provided on the cab dash near the driver's position to allow the silencing of the audible alarm for "Do Not Move" apparatus alarm due to door open indicator. This shall allow the audible alarm to be silenced momentarily until next park brake cycle.

PO00009693 - DUNNAGE AREA LIGHTING, TECNIQ EON 3 LED
Two (2) stainless-steel, Tecniq Eon 3-LED horizontal surface mounted lights shall be provided in the dunnage area to provide adequate illumination of this area.

These lights shall be switched in the same manner as the step lights.

PO00011816 - COMPARTMENT LIGHT ACTIVATION
Compartment lighting shall be switched either from an integral switch as provided by the roll up door manufacturer or a magnetic proximity switch if it is a KME manufactured door.

Page 240 of 508 ends

16.H

Page 1304 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 73 of 140 PO00003422 - COMPARTMENT LIGHTS, AMDOR LUMA BAR LED LIGHTING - DUAL Each individual, equipment storage compartment shall be equipped with the AMDOR, Luma Bar, LED light fixture, mounted on each side of the forward (and rear) vertical door frame.

PO00010734 - CUST PUMP/TANK/RES BODY LED MARKER LIGHTS
PO00002998 - OPTRONICS MARKER LIGHTS FORWARD OF FRONT CAB DOOR Optronics MCL series amber LED marker lights with reflector shall be provided and mounted forward of the front cab door, one (1) each side.

PO00002999 - OPTRONICS MARKER/TURN LIGHTS @ EA SIDE OF BODY Optronics model MCL82RB, red, LED marker lights with integral reflectors shall be provided at the lower side rear, having one (1) on each side.

Optronics Model #STL71AMB, yellow, LED side marker and turn lights shall be provided on the apparatus lower side, forward of rear axle that puts one (1) on each side, if the apparatus is 30' long or longer. ***SPECIAL: SP00020010 - TRUCK-LITE MARKER LIGHTS @ REAR OF BODY Truck-Lite Model #30 red LED clearance lights shall be provided on the apparatus rear upper having one (1) on each side at the outermost practical location.

PO00003007 - TRUCK-LITE DOT AMBER REFLECTORS @ SIDE OF BODY Truck-Lite # 98034Y, yellow reflectors shall be provided on the apparatus body lower side, as far forward and low as practical with one (1) on each side if the apparatus is 30' long or longer.

PO00003008 - TRUCK-LITE DOT RED REFLECTORS @ REAR OF BODY Truck-Lite # 98034R, red reflectors shall be provided on the apparatus rear with one (1) on each side at the outermost practical location.

PO00026701 - TECNIQ #L10 LED LICENSE PLATE LIGHT
One (1) Tecniq model #L10 LED license plate light shall be provided above the mounting position of the license plate.

The light shall be clear in color and shall have a chrome finish.

PO00003037 - WHELEN C6 LED BRAKE, REVERSE, TURN W/ QUAD HOUSING Two (2) Whelen C6 series, 4-1/8" x 6-1/2", LED red combination tail and stop lights, shall be mounted one each side at the rear of the body.

Page 241 of 508 ends

16.H

Page 1305 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 74 of 140 Two (2) Whelen C6 series, 4-1/8" x 6-1/2", LED amber arrow turn signal lights, shall be mounted one each side, on a vertical plane with the tail/stop lights.

Two (2) Whelen C6 series, 4-1/8" x 6-1/2", LED white back-up lights, shall be mounted one each side on a vertical plane with the turn/tail/stop signals.

These lights shall activate when the transmission is placed in reverse gear.

Two (2) Whelen PLASC4V mounting flanges, installed one (1) on each side, shall be provided to mount the lights described above in one common mounting flange.

The fourth opening shall be for the lower rear warning lights.

The lights shall be mounted in order, from top to bottom, as described above. ***SPECIAL: SP00020013 - PUMP ENCLOSURE WORK LIGHTS - TECNIQ LED Four (4) Tecniq, model #E18 lights shall be provided inside the pump enclosure, providing 800 lumens each.

Two (2) towards the driver side, and two (2) towards the officer side. Each light shall have their own independent switch incorporated into the light head. The lights shall be controlled (turn on/off) via mechanically fastened door sensors on the officer side fully hinged panel and the driver side upper gauge panel.

PO00003075 - BODY STEP LIGHTS, TECNIQ EON 3 LED, ALL DEVICES Polished, stainless-steel, Tecniq Eon 3-LED, horizontal surface, mounted body step lights shall be provided and controlled with marker light actuation.

Step lights shall be located to properly illuminate all body access steps and walkway areas and shall include a mounting gasket to provide a watertight seal.
***SPECIAL: SP00017074 - AMDOR LED STRIP HOSE BED LIGHTS-SIDES OF HOSEBED ON WALLS Two (2) Amdor 40" long LED strip surface mounted lights shall be mounted on the hose bed cover doors, one on each door. The light strips will be mounted on the high side of the doors when opened and angle down into the hose bed.

The hose bed work lights shall be switched on/off by raising and lowering the hose bed covers. ***SPECIAL: SP00037856 - REAR CAB WALL LIGHT - EXTERIOR One (1) Whelen C6 White LED light shall be provided and mounted high and centered on the cab exterior rear wall. The light shall be activated by the hose bed light switch and rear scene light switch.

PO00003172 - WHELEN C9 SERIES LED SCENE LIGHTS BEHIND FRONT CAB DOORS Two (2) Whelen, # C9SL, super LED scene lights shall be provided, (1) one on each side of the cab, directly behind the front cab entrance door in a chrome plated flange.

Page 242 of 508 ends

16.H

Page 1306 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 75 of 140 The scene lights shall be wired through the load management system. ***SHOP NOTE: SR00152735 - WHELEN C9 SERIES LED SCENE LIGHTS BEHIND FRONT CAB DOORS The lights shall be installed so that the front edge of the light bezels are aligned with the front edge of the exterior cab compartment doors.

PO00003173 - WHELEN C9 SERIES LED SCENE LIGHTS ON REAR OF BODY Two (2) Whelen, # C9SL, super LED scene lights shall be provided, (1) one on each side of the rear body panel in a chrome plated flange.

The scene lights shall be wired through the load management system.

PO00003244 - CAB SCENE LIGHTS TO BE ACTIVATED BY CAB DOORS In addition to the cab mounted switch for the cab scene lights, the driver and officer cab doors shall activate the respective light when a cab door is opened.

PO00003245 - REAR SCENE LIGHTS TO BE ACTIVATED BY REVERSE LIGHTS In addition to the cab mounted switch for the rear scene lights, the rear scene lights shall illuminate when the transmission is placed in reverse gear and the apparatus is operating as an emergency vehicle (Primary Warning switch on).

PO00011814 - CHASSIS SINGLE ELECTRIC (DOT) HORN
A single electric horn activated by the steering wheel horn button shall be furnished.

PO00004198 - ECCO #505 BACK-UP ALARM - 87 DBA
An ECCO # 505, 87dBA back-up alarm, shall be provided and installed at the rear of the apparatus under the tailboard.

The back-up alarm shall activate automatically when the transmission is placed in reverse gear and the ignition is "on."
PO00024127 - DUAL CHROME AIR HORNS - GROVER
Two (2) chrome plated Grover air horns shall be at the front of the vehicle. The air horns shall be mounted in full compliance with NFPA-1901. The supply lines shall be dual 1/4" lines with equal distance from each horn.

PO00002943 - DUAL AIR HORNS RECESSED IN DRIVER SIDE OF FRONT BUMPER Both air horns shall be recessed in the driver side of the front bumper.

Page 243 of 508 ends

16.H

Page 1307 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 76 of 140 PO00026141 - HORN SELECTOR - AIR/ELECTRIC
A multi selection button shall be provided in the multiplex screen to activate from the steering wheel horn button one of the following:
• DOT electric horn
• Air horn
***SHOP NOTE: SR00152736 - CHASSIS SINGLE ELECTRIC (DOT) HORN The steering wheel shall default to the air horn.

PO00026745 - AIR HORN CONTROL - CEILING MOUNTED LANYARD/STEERING WHEEL HORN BUTTON FOR DRIVER
The air horn(s) shall be controlled by a pull chain/cable and steering wheel horn button for the driver.

PO00004211 - SIREN, WHELEN # 295HFS2, 200W - FLUSH MOUNT One (1) Whelen # 295HFS2, 200-watt electronic siren shall be provided featuring: flush mount remote control head recessed in center dash panel as space allows, "Si-Test" self-diagnostic feature, six (6) function siren, radio repeat, and public address.

The electronic siren and speaker shall meet the NFPA required SAE certification to ensure compatibility between the siren and speaker.

PO00004236 - TWO (2) WHELEN SP123BMC SPEAKERS
Two (2) Whelen, model # SP123BMC with chrome plated ABS outer flange, siren speakers shall be provided, recessed in the front bumper and wired to the electronic siren.

PO00024983 - POLISHED STEEL ELECTRONIC SIREN SPEAKER GRILL A custom electric siren speaker grill shall be provided. This grill shall include the KME company logo cut into the center.

PO00012247 - FEDERAL Q2B SIREN @ CAB FRONT
One (1) Federal Model #Q2B mechanical siren shall be provided to provide audible warning.

PO00012253 - Q2B MOUNT - SEMI-RECESSED INTO DRIVER'S SIDE OF BUMPER The Q2B siren shall be semi-recessed into the bumper on the driver's side.

The siren shall be recessed so the front grille portion of the siren is exposed and protruding beyond the bumper.

Page 244 of 508 ends

16.H

Page 1308 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 77 of 140 PO00026753 - ELECTRO/MECHANICAL SIREN BRAKE CONTROL - DASH SWITCH, DRIVER SIDE A dash mounted push button switch shall be provided for the driver to control the brake on the electro/mechanical siren.

PO00026761 - ELECTRO/MECHANICAL SIREN CONTROL - FLOOR SWITCH, DRIVER SIDE A floor mounted foot switch shall be provided for the driver to activate the electro/mechanical siren. ***SPECIAL: SP00037862 - COMMUNICATIONS EQUIPMENT
All communications equipment including (but not limited to) mobile radio(s), antenna(s), intercom system, and AM/FM radio shall be provided and installed by Johnson Equipment of Perris, CA after delivery of the completed apparatus. KME California shall budget $15,000 towards the purchase and installation of this equipment. Any additional costs above this budgeted amount shall be the responsibility of the Hemet Fire Department.

PO00004695 - HALE QMAX-150 1500 GPM SINGLE STAGE PUMP
• HALE QMAX-150
• 1500 G.P.M.

Single Stage The pump must deliver the percentage of rated capacity at the pressure listed below:
• 100% of rated capacity at 150 P.S.I. net pump pressure • 100% of rated capacity at 165 P.S.I. net pump pressure • 70% of rated capacity at 200 P.S.I. net pump pressure • 50% of rated capacity at 250 P.S.I. net pump pressure.

The pump shall be of a size and design to mount on the chassis rails of commercial and custom truck chassis and have the capacity of 1500 gallons per minute (U.S. GPM), NFPA-1901 rated performance.

The entire pump shall be manufactured and tested at the pump manufacturer's factory. The pump shall be driven by a drive line from the truck transmission. The engine shall provide sufficient horsepower and RPM to enable the pump to meet and exceed its rated performance. The entire pump both suction and discharge passages, shall be hydrostatically tested to a pressure of 600 PSI. The pump shall be fully tested at the pump manufacturer's factory to performance specs as outlined by the latest NFPA-1901. Pump shall be free from objectionable pulsation and vibration. The pump body and related parts shall be of fine grain alloy cast iron with a minimum tensile strength of 30,000 PSI. All moving parts in contact with water shall be of high-quality bronze or stainless-steel. Pumps utilizing castings made of lower tensile strength cast iron are not acceptable.

Pump body shall be horizontally split on a single plane in two sections for easy removal of entire impeller assembly including wear rings and bearings from beneath the pump without disturbing piping or the mounting of the pump in chassis.

Page 245 of 508 ends

16.H

Page 1309 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 78 of 140 Pump shaft to be rigidly supported by three bearings for minimum deflection. One high lead bronze sleeve bearing shall be located immediately adjacent to the impeller (on side opposite the gearbox). The sleeve bearing is to be lubricated by a force fed, automatic oil lubricated design, pressure balanced to exclude foreign material. The pump shaft shall be heat-treated, electric furnace, corrosion resistant stainless-steel to be superfinished under packing with galvanic corrosion (zinc foil separators in packing) protection for longer shaft life.

Pump shaft must be sealed with double-lip oil seal to keep road dirt and water out of gearbox.

The pump shall have one double suction impeller. The pump body shall have two opposed discharge volute cutwaters to eliminate radial unbalance. Pump impeller shall be hard, fine grain bronze of the mixed flow design, accurately machined, and individually balanced. The vanes of the impeller intake eyes shall be of sufficient size and design to provide ample reserve capacity utilizing minimum horsepower. Impeller clearance rings shall be bronze, easily renewable without replacing impeller or pump volute body, and of wrap-around double labyrinth design for maximum efficiency.

PO00010950 - HALE CBP-250, 250 GPM PTO PUMP - PUMP AND ROLL A dedicated pump shall be provided for pump-and-roll and light volume stationary pumping.

The details of the pump are as follows:
• HALE CBP 250
• 250 GPM
• SINGLE STAGE
• PTO DRIVEN
A Hale model CBP-250 PTO driven pump shall be provided and installed.

The pump shall be of a size and design to mount on the chassis rails of commercial and custom truck chassis and have a maximum capacity of 250 gallons per minute (U.S. GPM), NFPA rated performance.

The entire pump shall be manufactured and tested at the pump manufacturer's factory.

The engine shall provide sufficient horsepower and RPM to enable pump to meet and exceed its rated performance.

The entire pump, both suction and discharge passages shall be hydrostatically tested to a pressure of 600 PSI.

The pump shall be fully tested at the pump manufacturer's factory to performance specs as outlined by the latest NFPA Pamphlet No. 1901. Pump shall be free from objectionable pulsation and vibration. The pump body and related parts shall be of fine grain alloy cast iron, with a minimum tensile strength of 30,000 PSI. All moving parts in contact with water shall be of high-quality bronze or stainless-steel. Pump utilizing castings made of lower tensile strength cast iron not acceptable.

The pump shaft shall be rigidly supported by two deep groove ball bearings for minimum deflection.

The pump shaft shall be heat-treated, electric furnace, corrosion resistant, stainless-steel.

Page 246 of 508 ends

16.H

Page 1310 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 79 of 140 The pump impeller shall be hard, fine grain bronze of the mixed flow design: accurately machined, hand ground and individually balanced. The vanes of the impeller intake eye shall be hand ground. The impeller shall be of sufficient size and design to provide ample reserve capacity utilizing minimum horsepower. Impeller shall be keyed to pump shaft and locked in place with a stainless-steel lock nut.

PO00010792 - PUMP RATIO
The pump ratio shall be selected by the apparatus manufacturer to give maximum performance with the engine and transmission selected.

The manufacturer shall supply at time of delivery copies of the pump manufacturer's certification of hydrostatic testing, the engine manufacturer's current certified brake horsepower curve.

PO00009802 - PUMP MOUNTS - MID-SHIP PUMPS
Extra heavy duty pump mounting brackets shall be furnished.

These shall be bolted to the frame rails in such a position to perfectly align the pump so that the angular velocity of the drive line joints shall be the same on each end of the drive shaft.

This shall assure full capacity performance with a minimum of vibration. Mounting hardware shall utilize Grade 8 bolts.

PO00009803 - PUMP MOUNTS - PTO PUMPS
Extra heavy duty pump mounting brackets shall be furnished.

These shall be bolted to the frame rails in such a position to perfectly align the pump with the PTO, so that the angular velocity of the drive line joints shall be the same on each end of the drive shaft.

This shall assure full capacity performance with a minimum of vibration. Mounting hardware shall utilize Grade 8 bolts.

PO00009138 - HALE MECHANICAL PUMP SEAL
The mid ship pump shall be equipped with a high quality, spring loaded, self-adjusting mechanical seal capable of providing a positive seal to atmosphere under all pumping conditions.

This positive seal to atmosphere must be achievable under vacuum conditions up to 26 Hg (draft) or positive suction pressures up to 250 PSI.

The mechanical seal assembly shall be 2 inches in diameter and consists of a carbon sealing ring, stainlesssteel coil spring, Viton rubber boot, and a tungsten carbide seat with a Teflon backup seal provided.

Page 247 of 508 ends

16.H

Page 1311 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 80 of 140 Only one (1) mechanical seal shall be required, located on the first stage suction (inboard) side of the pump and be designed to be compatible with a one-piece pump shaft.

A continuous cooling flow of water from the pump shall be directed through the seal chamber when the pump is in operation.

PO00009105 - HALE PUMP "G" DRIVE UNIT, ALL HALE FULL CAST PUMPS The drive unit shall be completely assembled and tested at the pump manufacturer's factory.

Pump drive unit shall be of sufficient size to withstand up to 16,000 lbs. ft. of torque of the engine in both road and pump operating conditions.

The drive unit shall be designed of ample capacity for lubrication reserve and to maintain the proper operating temperature.

The gearbox drive shafts shall be of heat-treated chrome nickel steel and at least 2-3/4 inches in diameter on both the input and output drive shafts.

They shall withstand the full torque of the engine in both road and pump operating conditions.

All gears, both drive and pump, shall be of the highest quality electric furnace chrome nickel steel.

Bores shall be ground to size and teeth integrated, chrome-shaven and hardened, to give an extremely accurate gear for long life, smooth, quiet running and higher load carrying capability.

An accurately cut spur design shall be provided to eliminate all possible end thrust.

PO00022942 - HALE CBP DRIVE UNIT
The drive unit, as well as the entire pump, shall be completely manufactured at the pump manufacturer's factory. The drive unit bearings shall be heavy duty and precision ground to size. The drive unit shall be of sufficient size to withstand the full torque of the pumping operation. The drive unit shall have ample capacity for lubrication reserve and maintain the proper operating temperature.

All gears shall be of highest quality steel alloys. They shall have case hardened teeth, to give long life, smooth, quiet running and higher load carrying capability. An accurately cut spur design shall be provided to eliminate all possible end thrust.

PO00024017 - PTO UNIT - HALE INTERFACE PUMPING SYSTEM
A hot shift Power Take Off shall be provided to drive the pump-and-roll impeller. The PTO shall be controlled by an electric "Hot-Shift" lighted rocker switch on the cab dash. This switch shall activate the low volume / pump-and-roll portion of the pumping system.

Page 248 of 508 ends

16.H

Page 1312 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 81 of 140 PO00010793 - PUMP SHIFT MANUAL OVERRIDE
An emergency manual pump shift control shall be furnished on the left side pump panel which may be utilized if the air shift control does not operate. A transmission, manual lock-up switch shall be furnished in the cab to ensure positive lock-up of the transmission.

PO00012078 - HALE PUMP SHIFT INDICATOR LIGHTS
For automatic transmissions, three (3) green warning lights shall be provided to indicate to the operator(s) when the pump has completed the shift for Road to Pump position.

Two (2) green lights to be located in the truck driving compartment and one (1) green light on pump operator's panel adjacent to the throttle control.

For manual transmissions, one (1) green warning light shall be provided for the driving compartment.

All lights to have appropriate identification/instruction plates.

PO00022947 - PTO PUMP AND ROLL INDICATOR LIGHTS
Three (3) indicator lights shall be provided in the cab interior. The “PUMP ENGAGED” light shall illuminate to indicate that the PTO is engaged.

The “OK TO PUMP” light shall be illuminated when:
1) the PTO is engaged.
2) the parking brake is set.
3) the transmission is in neutral.

The “OK TO PUMP AND ROLL” shall be illuminated when:
1) the PTO is engaged.
2) the parking brake is released.
3) the transmission is in any forward gear or reverse.

When the “OK TO PUMP AND ROLL” indicator is illuminated the “OK TO PUMP” indicator shall not be illuminated.

PO00022394 - MANIFOLD - DISCHARGE & SUCTION
A custom-made suction and discharge manifold shall be constructed from stainless-steel and/or flexible tubing. The manifold shall be designed to provide maximum efficiency for the suction inlets and the discharges. {No Exceptions}.

Page 249 of 508 ends

16.H

Page 1313 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 82 of 140 PO00011539 - HALE ANODE BLOCKS - ALLOY - 2-SUCTION/2-DISCHARGE Four (4) Hale Alloy anode blocks shall be provided and located two (2) on the suction side and two (2) on the discharge side of the pump to protect the pump from corrosion.

The Anodes shall be painted Safety Yellow for identification purposes. ***SPECIAL: SP00037869 - HALE THERMAL RELIEF VALVE - LIGHT AND BUZZER A Hale Model TRV-L120 Thermal Relief Valve shall be provided on the pump.

If water temperature in the pump exceeds 120 degrees Fahrenheit, the thermal relief valve shall automatically open and discharge pump water to the fill tower or tank, through a 3/8" discharge line, routed below the pump module. The TRV shall include a warning lamp and buzzer.

The thermal relief valve shall automatically close when the water temperature is lowered.

PO00010750 - AUXILIARY ENGINE COOLER
An auxiliary cooler or heat exchanger shall be installed in the engine compartment between the engine and the chassis radiator.

The cooler shall permit the use of water from the pump for cooling the engine.

The cooling shall be done without mixing engine and pump water.

PO00004802 - CLASS ONE "TPG" GOVERNOR CONTROL
Apparatus shall be equipped with a Class 1 Total Pressure Governor (TPG) that is connected to the Electronic Control Module (ECM) mounted on the engine.

The TPG shall operate as a pressure sensor (regulating) governor (PSG) utilizing the engines J1939 data for optimal resolution and response.

Programmable presets for RPM and Pressure settings shall be easily configurable using the TPGs straightforward menu structure.

The TPG shall also include indication of engine RPM, system voltage, engine oil pressure, and engine temperature with audible alarm output for all.

The TPG uses the J1939 data bus for engine information, requiring no additional sensors to be installed.

PO00011411 - ELKHART STYLE #40 INTAKE RELIEF VALVE
An Elkhart Model 40 intake relief valve system shall be plumbed on the suction side of the pump to comply fully with NFPA-1901 requirements.

Page 250 of 508 ends

16.H

Page 1314 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 83 of 140 It shall have an adjustable pressure relief setting from 75 psi to 250 psi and is factory preset at 125 psi.

Excess pressures shall be plumbed to discharge water under the pump enclosure away from the pump operator.

PO00011419 - INTAKE RELIEF VALVE HOSE CONNECTION
The intake relief valve discharge shall be a 2 ½” pipe which terminates with a 2 ½” NST male thread. A “DO NOT CAP” warning tag shall be affixed to the appropriate pump panel.

PO00024428 - RELIEF VALVE - AUXILIARY PUMP
A relief valve shall be provided to maintain discharge pressure and shall be set according to pump range of operation.

PO00009128 - HALE OIL-LESS PRIMING SYSTEM - HALE PUMP
The priming pump shall be a 12-volt Hale model ESP Oil-Less, positive displacement vane type primer, electrically driven.

One priming control shall open the priming valve and start the priming motor.

The primer shall be capable of priming without the use of primer oil.

The primer shall be connected to the power source with a 300-amp fusible link.

The Hale primer shall be activated by a control located on the pump operator's panel.

The control shall activate the primer motor, which shall create a vacuum.

Valve actuation may be accomplished while the main pump is operational, if necessary to assure complete prime.

PO00004826 - CLASS ONE 12 PORT ROTARY MASTER DRAIN VALVE A Class One, rotary type, 12 port, multiple master drain valve shall be provided and controlled at the lower portion of the side pump panel.

The valve shall be located in pump compartment lower than the main body and connected in such a manner as to allow complete water drainage of the pump body and all required accessories.

Water shall be drained below the apparatus body and away from the pump operator.

PO00004830 - DRAINS/BLEEDER "INNOVATIVE CONTROLS" LIFT UP @ ALL 1-1/2" OR LARGER All lines shall drain through the master drain valve or shall be equipped with individual drain valves, easily accessible, and labeled.

Page 251 of 508 ends

16.H

Page 1315 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 84 of 140 One (1) individual "Innovative Control" lift up drain valve shall be furnished for each 1-1/2" or larger discharge port and each 2-1/2" gated auxiliary suction.

Drain/bleeder valves shall be located at the bottom of the side pump module panels. All drains and bleeders shall discharge below the running boards.

PO00004840 - SYNFLEX SUCTION, DISCHARGE, PRESSURE AND CONTROL LINES Small lines within the pump enclosure shall be constructed from Synflex hose.

Uses include but are not limited to such lines as priming control, gauge lines, drain lines, air control valves, pump shift, supplemental cooling, foam flush, and air bleeder valves.

PO00010965 - SUCTION INLETS - 6” INLETS
Two (2) 6" N.S.T. suction inlets shall be provided, one on the driver side and one on the officer side pump panel.

A removable strainer shall be installed on each inlet.

PO00024018 - SHORT NECK MAIN PUMP SUCTION INLETS
The main pump suction inlets shall be furnished with a short suction end, terminating with only the suction threads protruding through the side panel to minimize the distance an exterior appliance protrudes beyond the pump panel.

PO00012076 - BEHIND PANEL MOUNT
All side gated inlet valves shall be recess mounted behind the side pump panels or body panels. There will be no exceptions.

PO00023976 - 6" NST INTAKE CAP - DRIVER SIDE
A 6" NST chrome plated long handle pressure vented cap shall be installed on driver side intake.

PO00023980 - 6" NST INTAKE CAP - OFFICER SIDE
A 6" NST chrome plated long handle pressure vented cap shall be installed on officer side intake.

PO00011334 - 2-1/2" DRIVER SIDE AUX SECONDARY SUCTION INLET REAR OF MAIN One (1) 2-1/2" auxiliary suction shall be provided at the driver side pump panel, to the rear of the main inlet (if space and other components allow).

The 2-1/2" auxiliary suction shall terminate with a removable strainer, chrome plated 2-1/2" NST female swivel with a chrome plated plug and retaining chain.

Page 252 of 508 ends

16.H

Page 1316 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 85 of 140 PO00004965 - 2-1/2" AKRON #8800 S.S. BALL VALVE, DRIVER SIDE REAR AUX SUCTION An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side rear auxiliary suction.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00004978 - SWING CONTROL @ VALVE, DRIVER SIDE REAR AUX SUCTION A 1/4 turn swing control handle shall be provided on the driver side rear auxiliary suction valve.

PO00011323 - TANK TO PUMP
One (1) 4" tank to pump line shall be piped through the front bulkhead of the tank with a 90-degree elbow down into the tank sump.

This line shall be plumbed directly into the rear of the pump suction manifold for maximum efficiency.

A check valve shall be provided to prevent accidental pressurization of the water tank through the pump connection.

Connection from the valve to the tank shall be made by using a non-collapsible flexible rubber hose.

PO00004999 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE, TANK TO PUMP An Akron Brass 3" Generation II Swing-Out Valve shall be provided between the pump suction manifold and the water tank.

The valve shall have an all-brass body with flow optimizing, stainless-steel ball and dual polymer seats.

PO00010956 - 3" PUSH/PULL CONTROL FOR TANK TO PUMP
A push/pull control handle shall be located on the operator's panel with function plate.

PO00022945 - PUMP AND ROLL PLUMBED TO MAINT TANK
The auxiliary pump-and-roll pump shall be plumbed into the main tank-to-pump line downstream of the tankto-pump valve.

PO00011326 - PUSH-PULL CONTROL NORMALLY OPEN - IN / OPEN, OUT / CLOSE The tank-to-pump push pull handle shall be oriented so that it is "IN" to "OPEN" and "OUT" to "CLOSE".

This shall allow it to be normally open for pump-and-roll operations.

Page 253 of 508 ends

16.H

Page 1317 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 86 of 140 PO00010962 - TANK FILL LINE 2" FROM PUMP - SIDE MOUNT
One (1) 2" gated full flow pump to tank refill line controlled at the pump panel shall be provided. A deflector shield inside the tank shall be furnished. Tank fill plumbing shall utilize 2" high pressure hose for tank connection to accommodate flexing between components. There will be no exceptions.

PO00005031 - 2" AKRON #8800 SERIES - S.S. BALL TANK FILL, SIDE MOUN An Akron Brass 2" Generation II Swing-Out Valve shall be provided between the pump discharge manifold and the water tank.

The valve shall have an all-brass body with flow optimizing, stainless-steel ball, and dual polymer seats.

PO00009815 - PUSH/PULL CONTROL FOR TANK FILL
A push/pull control handle shall be located on the operator's panel with function plate.

PO00012083 - DRIVER SIDE MAIN DISCHARGE #1
A discharge shall be provided and located at the driver's side pump panel.

The driver's side discharges # 1 shall terminate with NST threads, through the left panel above the main pump intake.

The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.

PO00009226 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, DRIVER SIDE #1 An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side #1 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00005054 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP DRIVER SIDE DISCHARGE #1 A 2-1/2" NSTF X 1-1/2" NSTM reducer with cap shall be provided on the driver's side # 1 discharge.

PO00005039 - DS #1 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight 2 1/2" NST adapter that shall be equipped with a 2 1/2" NST, 30-degree, chrome plated elbow.

PO00005085 - SWING 1/4 TURN CONTROL FOR DRIVER SIDE DISCHARGE #1 -SIDE MOUNT The driver's side # 1 discharge valve shall be controlled by a 1/4 turn swing control handle located on the operator's panel.

Page 254 of 508 ends

16.H

Page 1318 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 87 of 140 PO00005131 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - DRIVER SIDE DISCHARGE #1 The driver's side # 1 discharge shall be equipped with a Class One, 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright, metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00005134 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.

PO00012084 - DRIVER SIDE MAIN DISCHARGE #2
A discharge shall be provided and located at the driver's side pump panel.

The driver's side discharges # 2 shall terminate with NST threads, through the left panel above the main pump intake.

The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.

PO00009304 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, DRIVER SIDE #2 An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side #2 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00005145 - DS #2 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight 2 1/2" NST adapter that shall be equipped with a 2 1/2" NST, 30-degree, chrome plated elbow.

PO00005160 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP DRIVER SIDE DISCHARGE #2 A 2-1/2" NSTF X 1-1/2" NSTM reducer with cap shall be provided on the driver's side # 2 discharge.

Page 255 of 508 ends

16.H

Page 1319 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 88 of 140 PO00005188 - SWING 1/4 TURN CONTROL FOR DRIVER SIDE DISCHARGE #2 -SIDE MOUNT The driver's side # 2 discharge valve shall be controlled by a 1/4 turn swing control handle located on the operator's panel.

PO00005233 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - DRIVER SIDE DISCHARGE #2 The driver's side # 2 discharge shall be equipped with a Class One, 2 1/2" pressure gauge, which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00005236 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.

PO00012086 - OFFICER SIDE MAIN DISCHARGE #1
A discharge shall be provided and located at the officer's side pump panel.

The officer's side discharges #1 shall terminate with NST threads, through the officer's side panel above the main pump intake.

The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.

PO00005281 - 4" AKRON #8840 VALVE, OFFICER SIDE #1, SIDE MOUNT An Akron Brass, 4" Heavy Duty, Swing-Out Valve shall be provided for the officer's side #1 discharge.

The valve shall have an all-brass body with flow optimizing, flat ball, and dual polymer seats PO00005298 - OS #1 DISCHARGE - 4" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight, 4" NST adapter that shall be equipped with a 4" NST, 30-degree, chrome plated elbow.

Page 256 of 508 ends

16.H

Page 1320 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 89 of 140 ***SPECIAL: SP00020023 - 4" NSTF X 2.5" NSTM REDUCER WITH CAP OFFICER SIDE DISCHARGE # 1 A 4" NSTF X 2.5" NSTM reducer with cap shall be provided on the officer's side # 1 discharge.

PO00005362 - AKRON HANDWHEEL GEAR VALVE CONTROL, OFFICER SIDE DISCHARGE #1 The officer's side # 1 discharge valve shall be gated with an Akron Hand wheel controlled, inline valve.

The valve shall be controlled at the pump operator's panel with a chrome plated hand wheel and mechanical valve position indicator.

PO00005380 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - OFFICER SIDE DISCHARGE #1 The officer's side, # 1 discharge shall be equipped with a Class One, 2 1/2" pressure gauge which shall contain a vibration dampened, internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00005383 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.

PO00012087 - OFFICER SIDE MAIN DISCHARGE #2
A discharge shall be provided and located at the officer's side pump panel.

The officer's side discharges #2 shall terminate with NST threads, through the officer's side panel above the main pump intake.

The main pump discharge shall be plumbed directly from the pump discharge manifold utilizing direct connect discharge valve flanges.

PO00005393 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, OFFICER SIDE #2, SIDE MOUNT An Akron Brass, 2 1/2" Generation II, Swing-Out Valve shall be provided for the officer's side #2 discharge.

The valve shall have an all-brass body with flow optimizing, stainless-steel ball, and dual polymer seats.

Page 257 of 508 ends

16.H

Page 1321 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 90 of 140 PO00005403 - OS #2 DISCHARGE - 2-1/2" STRAIGHT NST & 30-DEGREE NST ELBOW The discharge valve shall be equipped with a straight, 2 1/2" NST, adapter that shall be equipped with a 2 1/2" NST, 30-degree, chrome plated elbow.

PO00005418 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER W/CAP OFFICER SIDE DISCHARGE #2 A 2-1/2" NSTF X 1-1/2" NSTM reducer w/ cap shall be provided on the officer's side #2 discharge.

PO00005447 - SWING 1/4 TURN CONTROL FOR OFFICER SIDE DISCHARGE #2 -SIDE MOUNT The officer's side, #2 discharge valve shall be controlled by a 1/4 turn swing control handle located on the operator's panel.

PO00005492 - CLASS ONE, LIGHTED, 2-1/2" PRESS GA - OFFICER SIDE DISCHARGE #2 The officer's side, #2 discharge shall be equipped with a Class One, 2 1/2" pressure gauge which shall contain a vibration dampened, internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright, metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00005495 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated, Class One gauge shall be Red.

PO00012097 - OFFICER SIDE REAR DISCHARGE 2-1/2"
A 2 1/2" NST rear discharge shall be provided at the rear of the vehicle, plumbed from the pump.

PO00005741 - OS REAR DISCHARGE TERMINATE @ OFFICER SIDE REAR BODY PANEL The rear discharge shall terminate on the rear body panel, on the officer side of the body.

PO00005745 - 2-1/2" NST MALE THREADS ON OFFICER SIDE REAR DISCHARGE The discharge shall be equipped with a 30-degree droop terminating in 2-1/2" NSTM threads.

The officer side rear discharge pipe shall be furnished with 2-1/2" NSTM threads.

Page 258 of 508 ends

16.H

Page 1322 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 91 of 140 PO00005752 - OS REAR DISCHARGE, PLUMBING, 2-1/2" STAINLESS-STEEL PIPING The officer side rear discharge shall be plumbed utilizing 2 1/2" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

PO00005761 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE REAR DISCHARGE An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the officer's side rear discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00005774 - PUSH/PULL CONTROL FOR OFFICER SIDE REAR DISCHARGE The officer side rear discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00005819 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP - OFFICER SIDE REAR DISCHARGE A 2-1/2" NSTF X 1-1/2" NSTM reducer(s) with cap shall be provided on the officers’ side rear discharge.

PO00005850 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - OFFICER SIDE REAR DISCHARGE The officer side rear discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00005853 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.

PO00012103 - DRIVER SIDE HOSE BED DISCHARGE 2-1/2"
A 2 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front of the hose bed.

Page 259 of 508 ends

16.H

Page 1323 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 92 of 140 PO00005863 - DS HOSE BED DISCHARGE TERMINATE @ FLOOR LEVEL FRONT The rear hose bed discharge shall terminate just above the hosebed floor, in the driver side front of the hose bed.

PO00005867 - 2-1/2" NST MALE THREADS ON DRIVER SIDE HOSE BED DISCHARGE The driver side hose bed discharge pipe shall be equipped with a chrome 2 1/2" NSTM thread adapter.

PO00005871 - DS HOSE BED DISCHARGE, PLUMBING, 2-1/2" STAINLESS-STEEL PIPING The driver side hose bed discharge shall be plumbed utilizing 2 1/2" schedule 10 stainless-steel piping, 45- degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

PO00005876 - 2-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE DRIVER SIDE HOSE BED DISCHARGE An Akron Brass 2 1/2" Generation II Swing-Out Valve shall be provided for the driver's side hose bed rear discharge. The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00005886 - PUSH/PULL CONTROL FOR DRIVER SIDE HOSE BED DISCHARGE The driver side hose bed discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00005935 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - DRIVER SIDE HOSE BED DISCHARGE The driver side hose bed discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00005938 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.

Page 260 of 508 ends

16.H

Page 1324 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 93 of 140 PO00012105 - OFFICER SIDE HOSE BED DISCHARGE 1-1/2"
A 1 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front of the hose bed.

PO00005948 - OS HOSE BED DISCHARGE TERMINATE @ FLOOR LEVEL FRONT The rear hose bed discharge shall terminate just above the hose bed floor, in the officer's side front of the hose bed.

PO00005950 - 1-1/2" NST MALE THREADS ON OFFICER SIDE HOSE BED DISCHARGE The officer's side hose bed discharge pipe shall be equipped with a chrome 1 1/2" NSTM thread adapter.

PO00005954 - OS HOSE BED DISCHARGE, PLUMBING, 2" STAINLESS-STEEL PIPING The officer's side hose bed discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

PO00005960 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE HOSE BED DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the officer's side hose bed discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00005971 - PUSH/PULL CONTROL FOR OFFICER SIDE HOSE BED DISCHARGE The officer's side hose bed discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00006014 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - OFFICER SIDE HOSE BED The officer's side hose bed discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

Page 261 of 508 ends

16.H

Page 1325 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 94 of 140 The gauge face shall be white with black numerals.

PO00006017 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.

PO00012151 - OFFICER SIDE HOSE BED DISCHARGE #2 - 1-1/2" A 1 1/2" rear hose bed discharge shall be plumbed to the upper front body panel, extending into the front of the hose bed.

PO00010354 - OS HOSE BED DISCHARGE #2 TERMINATE @ FLOOR LEVEL FRONT The rear hose bed discharge shall terminate just above the hose bed floor, in the officer's side front of the hose bed.

PO00010404 - 1-1/2" NST MALE THREADS ON OFFICER SIDE HOSE BED DISCHARGE #2 The officer's side hose bed discharge pipe shall be equipped with a chrome 1 1/2" NSTM thread adapter.

PO00010387 - OFFICER SIDE HOSE BED DISCHARGE #2, PLUMBING, 2" STAINLESS-STEEL PIPING The officer's side hose bed discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the rear of the vehicle.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

PO00010393 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE OFFICER SIDE HOSE BED DISCHARGE #2 An Akron Brass 2" Generation II Swing-Out™ Valve shall be provided for the officer's side hose bed discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00010356 - PUSH/PULL CONTROL FOR OFFICER SIDE HOSE BED DISCHARGE #2 The officer's side hose bed discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00010353 - 2-1/2" NSTF X 1-1/2" NSTM REDUCER WITH CAP - OFFICER SIDE HOSE BED DISCHARGE #2 A 2-1/2" NSTF X 1-1/2" NSTM reducer with cap shall be provided on the officers’ side hose bed discharge.

Page 262 of 508 ends

16.H

Page 1326 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 95 of 140 PO00010335 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - OFFICER SIDE HOSE BED DISCHARGE #2 The officer's side hose bed discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00010338 - RED ILLUMINATED GAUGE - CLASS ONE - OFFICER SIDE HOSE BED DISCHARGE #2 The color of the illuminated Class One gauge shall be Red.

PO00012108 - DECK GUN DISCHARGE
A deck gun discharge shall be plumbed from the pump to an area on top of the vehicle.

The deck gun piping shall be firmly supported and braced.

PO00006023 - DECK GUN DISCHARGE TERMINATE @ CENTER OF DUNNAGE The deck gun discharge shall be located in the center of the dunnage area above the pump module.

A pedestal type, 1/4" steel plate support assembly shall be provided to stabilize deck gun plumbing below deck gun mount flange.

PO00026331 - DECK GUN DISCHARGE TERMINATION TO MATCH DECK GUN The deck gun discharge pipe shall terminate with a connection matching the specified deck gun model and accessories.

PO00006036 - DECK GUN DISCHARGE - OVA HEIGHT NOT EXCEED CRITICAL OVERALL HEIGHT RESTRICTION Deck gun height will be limited to the critical overall apparatus height listed in the spec. To avoid excessive travel heights the monitor will be positioned as low a practical while still allowing functionality of water stream.

PO00006039 - DECK GUN DISCHARGE, PLUMBING, 3" STAINLESS-STEEL PIPING The deck gun discharge shall be plumbed utilizing 3" schedule 10 stainless-steel piping, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the deck gun location.

Page 263 of 508 ends

16.H

Page 1327 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 96 of 140 A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

PO00006045 - 3" AKRON #8800 SERIES - S.S. BALL, VALVE DECK GUN DISCHARGE An Akron Brass 3" Generation II Swing-Out Valve shall be provided for the deck gun discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00006058 - PUSH/PULL CONTROL FOR DECK GUN DISCHARGE
The deck gun discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00006101 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - DECK GUN DISCHARGE The deck gun discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00006104 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red. ***SPECIAL: SP00037855 - AKRON MODEL #3433 "HI-RISER" MANUAL DECK GUN KIT An Akron model # 3433 "HI-RISER" deck gun shall be supplied and mounted on the deck gun discharge of the unit to provide the maximum travel clearance. The monitor shall be equipped with a portable ground base with one 4" NSTF swivel inlet. The monitor shall come equipped with a set of stack tips and an Akron model # 1755 Turbomaster" 1250 GPM nozzle. The monitor shall also include the following: Pressure gauge on the monitor, carry handle for portable usage, grease fittings for maintenance, safety chains, hardened steel ground spikes and Pyrolite construction.

PO00012110 - #1 FRONT DISCHARGE 1-1/2"
A 1 1/2" front #1 discharge shall be plumbed to the front bumper of the vehicle.

Page 264 of 508 ends

16.H

Page 1328 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 97 of 140 PO00006327 - 1-1/2" NST CHICKSAN SWIVEL #1 DISCHARGE- HOSE WELL ON FRONT BUMPER The front #1 discharge shall terminate with a brass 1 1/2" NST chicksan swivel adapter in the hose well on the front bumper.

PO00006349 - #1 FRONT DISCHARGE, PLUMBING, 2" STAINLESS-STEEL PIPING The front #1 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping, flexible hosing, 45- degree elbows, and a limited number of 90 degree sweep elbows in an assembly from the pump to the front of the vehicle.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

Automatic discharge drains shall be provided at all low points in the plumbing.

PO00006360 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE FRONT#1 DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the front #1 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00006377 - PUSH/PULL CONTROL FOR FRONT #1 DISCHARGE
The front #1 discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00006427 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - FRONT #1 DISCHARGE The front #1 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00006430 - RED ILLUMINATED GAUGE - CLASS ONE - FRONT #1 DISCHARGE The color of the illuminated Class One gauge shall be Red, on the front #1 discharge.

Page 265 of 508 ends

16.H

Page 1329 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 98 of 140 PO00012113 - #2 FRONT DISCHARGE 1-1/2"
A 1 1/2" front discharge shall be plumbed to the front bumper of the vehicle.

PO00006443 - 1-1/2" NST CHICKSAN SWIVEL #2 DISCHARGE- HOSE WELL ON FRONT BUMPER The front discharge #2 shall terminate with a chrome 1 1/2" NST chicksan swivel adapter in a location on the front bumper as directed by engineering.

PO00006468 - #2 FRONT DISCHARGE, PLUMBING, 2" STAINLESS-STEEL PIPING The front discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45- degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to the front of the vehicle.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly to allow for flex and serviceability.

Automatic discharge drains shall be provided at all low points in the plumbing.

PO00006479 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE FRONT #2 DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the front #2 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00006496 - PUSH/PULL CONTROL FOR FRONT #2 DISCHARGE
The front #2 discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00006546 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - FRONT #2 DISCHARGE The front #2 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

Page 266 of 508 ends

16.H

Page 1330 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 99 of 140 PO00006549 - RED ILLUMINATED GAUGE - CLASS ONE- FRONT #2 DISCHARGE The color of the illuminated Class One gauge shall be Red, on the front #2 discharge.

PO00000011 - CROSSLAY #1, 1-1/2" - PUMPER
A crosslay hose bed shall be provided and plumbed from the pump in a transverse design, located above the pump enclosure for quick attack deployment. The crosslay hose bed flooring shall be designed to be removable and constructed from brushed finish, perforated aluminum material.

PO00000014 - CROSSLAY #1 CAPACITY - 200 FEET OF 1-3/4" HOSE Crosslay #1 shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA -1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.

PO00000022 - CROSSLAY #1 - DOUBLE STACK HOSE DESIGN
Crosslay #1 hose bed shall be designed to accommodate the fire hose in a double stack configuration.

PO00006565 - 1-1/2" NST CHICKSAN SWIVEL - CROSSLAY #1
The crosslay discharge shall terminate below the hosebed floor with a 1 1/2" NSTM chicksan swivel adapter.

The crosslay hose bed floor shall be slotted to allow the swivel to extend up through the floor, allowing the pre-connected hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.

PO00006572 - CROSSLAY #1, PLUMBING, 2" STAINLESS-STEEL PIPING The crosslay #1 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to crosslay hose bed.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly, if necessary, to allow for flex and serviceability.

PO00006578 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE CROSSLAY #1, DISCHARGE An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the crosslay #1 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00006592 - PUSH/PULL CONTROL CROSSLAY #1
The crosslay #1 discharge valve shall be controlled by a push/pull handle located on the operator's panel.

Page 267 of 508 ends

16.H

Page 1331 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 100 of 140 PO00006635 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - CROSSLAY #1 The crosslay #1 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00006638 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.

PO00007712 - CROSSLAY #2 1-1/2"
A crosslay hose bed shall be provided and plumbed from the pump in a transverse design, located above the pump enclosure for quick attack deployment.

The crosslay hose bed flooring shall be designed to be removable, constructed from brushed finish, perforated aluminum material.

PO00000024 - CROSSLAY #2 CAPACITY - 200 FEET OF 1-3/4" HOSE Crosslay #2 shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA -1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.

PO00000032 - CROSSLAY #2 - DOUBLE STACK HOSE DESIGN
Crosslay #2 hose bed shall be designed to accommodate the fire hose in a double stack configuration.

PO00024219 - 1-1/2" NST CHICKSAN SWIVEL - CROSSLAY #2
The crosslay discharge shall terminate below the hose bed floor with a 1 1/2" NSTM chicksan swivel adapter.

The crosslay hose bed floor shall be slotted to allow the swivel to extend up through the floor, allowing the pre-connected hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.

Page 268 of 508 ends

16.H

Page 1332 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 101 of 140 PO00006661 - CROSSLAY #2, PLUMBING, 2" STAINLESS-STEEL PIPING The crosslay #2 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to crosslay hose bed.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly, if necessary, to allow for flex and serviceability.

PO00006667 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE CROSSLAY #2, An Akron Brass 2" Generation II Swing-Out Valve shall be provided for the crosslay #2 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats.

PO00006681 - PUSH/PULL CONTROL CROSSLAY #2
The crosslay #2 discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00006722 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - CROSSLAY #2 The crosslay #2 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00006725 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.

PO00007715 - CROSSLAY #3 1-3/4"
A crosslay hose bed shall be provided and plumbed from the pump in a transverse design, located above the pump enclosure for quick attack deployment.

The crosslay hose bed flooring shall be designed to be removable, constructed from brushed finish, perforated aluminum material.

Page 269 of 508 ends

16.H

Page 1333 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 102 of 140 PO00000034 - CROSSLAY #3 CAPACITY - 200 FEET OF 1-3/4" HOSE Crosslay #3 shall be designed to have a minimum total capacity of 3.5 cubic feet as required by NFPA -1901 to accommodate a minimum of 200 feet of 1-3/4" fire hose.

PO00000042 - CROSSLAY #3 - DOUBLE STACK HOSE DESIGN
Crosslay #3 hose bed shall be designed to accommodate the fire hose in a double stack configuration.

PO00006741 - 1-1/2" NST CHICKSAN SWIVEL - CROSSLAY #3
The crosslay discharge shall terminate below the hosebed floor with a 1 1/2" NSTM chicksan swivel adapter.

The crosslay hose bed floor shall be slotted to allow the swivel to extend up through the floor, allowing the pre-connected hose to be pulled off either side of the apparatus without kinking the hose at the coupling connection.

PO00006744 - CROSSLAY #3, PLUMBING, 2" STAINLESS-STEEL PIPING The crosslay #3 discharge shall be plumbed utilizing 2" schedule 10 stainless-steel piping and/or flexible hose, 45-degree elbows and a limited number of 90 degree sweep elbows in an assembly from the pump to crosslay hose bed.

A minimum of one (1) grooved pipe coupling shall be furnished in this assembly, if necessary, to allow for flex and serviceability.

PO00006750 - PUSH/PULL CONTROL CROSSLAY #3
The crosslay #3 discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00006793 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - CROSSLAY #3 The crosslay #3 discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

Page 270 of 508 ends

16.H

Page 1334 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 103 of 140 PO00006796 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red.

PO00009196 - 2" AKRON #8800 SERIES - S.S. BALL, VALVE CROSSLAY #3, An Akron Brass 2" Generation II Swing-Out™ Valve shall be provided for the crosslay #3 discharge.

The valve shall have an all-brass body with flow optimizing stainless-steel ball and dual polymer seats. ***SPECIAL: SP00008482 - VINYL END FLAPS FOR ALUMINUM TREADPLATE CROSSLAY COVER Two (2) piece crosslay end flaps will be provided to accommodate the two individual crosslay doors. The flaps will attach at the bottom with postman straps and ¼ turn fasteners on the covers.

PO00011385 - END FLAP COVER BLACK IN COLOR
The crosslay end flap shall be black in color.
***SPECIAL: SP00017079 - PUMP ENCLOSURE HOSEBED HOSE RETENTION Provide two (2) 3/16” aluminum tread plate crosslay covers. One (1) will be forward hinged that will cover the front two crosslays and the second will be rear hinged that will cover the other remaining crosslays. Each lid will have a “D” handles on top to allow for easier opening. The forward lid shall have a rubber grommet centered in the middle of the cover to prevent the cover from contacting the scene light mounted on the rear cab wall.
***SPECIAL: SP00037845 - 6.5" FRONT CROSSLAY BULKHEAD
The crosslay bulkhead will be 6.5" wide to allow the front crosslay to clear the back of cab telescoping lights and allow space for backboard storage.
***SPECIAL: SP00037878 - BACK BOARD STORAGE SLOT WITHIN CROSSLAY BULKHEAD A storage area within the front crosslay bulkhead shall be designed to accommodate one (1) backboard, the storage slot shall be sized 18" tall x 2" wide x 74" long to accommodate a standard size backboard. Each side shall be accessed by a forward hinged door with thumb latches. Door material to match the pump panel material.

The storage area shall have nylon material on the bottom surface to protect the backboard.

PO00012125 - BOOSTER REEL #1
PO00015491 - BOOSTER REEL #1 DISCHARGE
A 1 1/2" booster reel discharge shall be plumbed from the pump to the booster reel.

Page 271 of 508 ends

16.H

Page 1335 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 104 of 140 PO00015492 - BOOSTER REEL #1 DISCHARGE, PLUMBING, 1" HOSE The booster reel discharge shall be plumbed from the valve to the hose reel utilizing 1" hose. The end of the hose connected to the hose reel shall be equipped with a swivel end for ease in hose replacement.

PO00007275 - 1-1/2" AKRON #8800 SERIES - S.S. BALL, VALVE BOOSTER REEL A 1 1/2" Akron, #8800 series, full flow, stainless-steel ball valve shall be provided for the booster reel #1 discharge.

PO00007282 - PUSH/PULL CONTROL FOR BOOSTER REEL #1
The booster reel discharge valve shall be controlled by a push/pull handle located on the operator's panel.

PO00007305 - CLASS ONE, LIGHTED, 2-1/2" PRESS GAUGE - BOOSTER REEL #1 The booster reel discharge shall be equipped with a Class One 2 1/2" pressure gauge which shall contain a vibration dampened internal mechanism.

To prevent internal freezing, the stem and Bourdon tube shall be filled with low temperature oil and be sealed from the water system using an isolating diaphragm located in the stem.

A bright metal bezel shall be supplied for resistance to corrosion and to protect the lens and case from damage.

The pressure gauge shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00007308 - RED ILLUMINATED GAUGE - CLASS ONE
The color of the illuminated Class One gauge shall be Red. ***SPECIAL: SP00037842 - BOOSTER REEL #1 - HANNAY ALUMINUM BOOSTER REEL #1 One (1) Hannay, aluminum, Super Booster, electric rewind booster reel shall be furnished.

The reel shall be equipped with a one (1) inch 90 full flow swivel joint and an adjustable brake for freewheeling, drag or full lock operation.

Reel model shall be 30-20-24 with NPSH threads.

PO00007315 - BOOSTER REEL #1 LOCATED ABOVE PUMP ENCLOSURE - OFFICER SIDE The booster reel #1 shall be mounted above the pump enclosure towards the officer side of the unit.

Page 272 of 508 ends

16.H

Page 1336 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 105 of 140 ***SPECIAL: SP00037841 - BOOSTER REEL COVER
The booster reel shall be enclosed in a 3/8" tread plate cover with hose roller guides exiting on the O/S of the dunnage area. Note: the booster reel enclosure shall be sturdy enough to be used as a stepping surface and hinged to allow for hose to be changed out. One (1) Tecniq E18 LED light shall be provided inside the enclosure activated by opening the upper door.

PO00007321 - HOSE REEL #1 REWIND OFFICER'S SIDE PUMP PANEL Booster reel rewind shall be controlled by a pump panel mounted push button on the officer's side panel.

The booster reel circuit shall be equipped with a shielded toggle switch to act as a booster reel disconnect to avoid accidental actuation of the booster reel rewind button. ***SPECIAL: SP00025691 - BOOSTER REEL #1 HOSE, 150 FEET OF 1" HOSE W/NPSH COUPLINGS Each booster reel shall be equipped with 150' of 1" booster hose in (1) 100' section and (1) 50' section.

Each length shall be fitted with NPSH couplings.
***SPECIAL: SP00008488 - BOOSTER HOSE NOZZLE
One (1) Task Force 1040 nozzle with bale and handle, for booster reel shall be provided. Thread to be NPSH.

No holder will be provided.

PO00007348 - CAPTIVE HOSE ROLLER ASSEMBLY FOR SIDE OF PUMP PANEL A captive roller arrangement shall be provided around the perimeter of the opening at the dunnage area allowing hose to be pulled out in any direction.

PO00007450 - FOAM SYSTEM STAINLESS PIPING - 1 INCH FROM FOAM SOURCE TO SYSTEM All foam concentrate plumbing from the tank or auxiliary foam inlet to the foam system components shall be stainless-steel and nonferrous material.

The foam system piping shall incorporate a check valve to prevent water from entering the foam tank; the discharge piping shall also include a check valve to prevent foam solution from back feeding into the discharge side of the pump.

Individual discharge piping shall be as specified for each discharge.

The complete foam system shall be tested in accordance with NFPA-1901.

PO00007474 - FOAMPRO 2001 CLASS "A AND/OR B" FOAM SYSTEM A FoamPro model 2001, electronic, fully automatic, variable speed, direct injection, discharge side foam proportioning system shall be installed in the pumping system.

Page 273 of 508 ends

16.H

Page 1337 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 106 of 140 The system shall be capable of handling Class "A" foam concentrates and most Class "B" foam concentrates.

The foam proportioning operation shall be based on direct measurement of water flows and remain consistent within the specified flows and pressures.

System must be capable of delivering accuracy to within 3% of calibrated settings over the advertised operation range when installed according to factory standards.

The system shall be equipped with a digital electronic control display suitable for installation on the pump panel.

Incorporated within the control display shall be a microprocessor that receives input from the system flow meter, while also monitoring foam concentrate pump output, comparing values to ensure that the operator preset proportional amount of foam concentrate is injected into the discharge side of the fire pump.

A paddlewheel-type flow meter shall be installed in the discharge or manifold system specified to be foam capable.

A Full flow check valve shall be provided to prevent foam contamination of fire pump and water tank or water contamination of foam tank.

A 12 or 24-volt electric motor drive positive displacement foam concentrate pump, rated up to 2.5 GPM (9.5 L/min) @ 150 psi with operating pressures up to 400 psi (27.6 BAR), shall be installed in a suitable, accessible location.

The system shall draw a maximum of 40 amps @ 12 VDC or 21 amps @ 24 VDC.

A pump motor electronic driver (mounted to the base of the pump) shall receive signals from the computer control display and power the 1/2 hp (0.40 Kw) electric motor directly coupled to the concentrate pump in a variable speed duty cycle to ensure that the correct proportion of concentrate preset by the pump operator is injected into the water stream.

The digital computer control display located on the pump operator's panel shall enable the pump operator to perform the following control and operation functions for the foam proportioning system:
• Provide push-button control of foam proportioning rates from 0.1% to 9.9%, in 0.1% increments • Show current flow-per-minute of water
• Show total volume of water discharged during and after foam operations are completed • Show total amount of foam concentrate consumed
• Simulate flow rates for manual operation
• Perform setup and diagnostic functions for the computer control microprocessor • Flash a low concentrate warning when the foam concentrate tank(s) runs low • Flash a no concentrate warning and shut the foam concentrate pump off, preventing damage to the pump, should the foam tank(s) empty
The digital computer control display shall interface with the options listed; provide dual foam calibration and display separate totals for each foam concentrate used.

Page 274 of 508 ends

16.H

Page 1338 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 107 of 140 If two foam tanks are required and piped to the foam concentrate pump, either an electric dual tank valve or the manual dual tank valve shall be provided.

Components of the complete proportioning system shall include:
• Operator control and display
• Paddlewheel flow meter
• Pump and electric motor/motor driver
• Wiring harnesses
• Low-level tank switch (Switches)
• Electronic dual tank valve or manual dual tank valve (if more than one tank) • Foam injection check valve
• Main waterway check valve
Accurate concentration proportioning can be achieved, based on the following water flows:
• 85 GPM water 3.0% concentration
• 260 GPM water 1.0% concentration
• 520 GPM water 0.5% concentration
• 1300 GPM water 0.2% concentration
Note: Multiple discharges plumbed to this system may affect performance if the flow rates are exceeded by any one discharge or the totality of multiple discharges at one time! PO00007498 - INJECTION SYSTEM DISCHARGE PLUMBING
The discharge piping shall be equipped with a properly sized flow meter sensor, based on the systems capabilities.

The foam system shall be plumbed to the following discharge/s through the discharge piping or manifold system:

PO00009151 - INJECTION FOAM SYSTEM INSTALLED ON CROSSLAY #1 Crosslay #1 discharge.

PO00009152 - INJECTION FOAM SYSTEM INSTALLED ON CROSSLAY #2 Crosslay #2 discharge.

PO00009153 - INJECTION FOAM SYSTEM INSTALLED ON CROSSLAY #3 Crosslay #3 discharge.

PO00009155 - FOAM SYSTEM INSTALLED ON FRONT DISCHARGE
Front discharge.

Page 275 of 508 ends

16.H

Page 1339 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 108 of 140 PO00009164 - INJECTION FOAM SYSTEM INSTALLED ON HOSEREEL # 1 Hose reel # 1 discharge.

PO00022343 - CLASS A - PHOS-CHEK WD881 BY MONSANTO
Class A – Phos-Chek WD881 manufactured by Monsanto.

PO00022367 - CLASS B - OTHER (MUST SPECIFY FOAM NAME AND MANUFACTURER) - TBD @ PRE-CON Class B - OTHER - (MUST SPECIFY FOAM NAME AND MANUFACTURER).

PO00022762 - INJECTION FOAM SYSTEM INSTALLED ON DRIVER SIDE HOSEBED DISCHARGE #1 Drivers side hosebed discharge #1
PO00022776 - INJECTION FOAM SYSTEM INSTALLED ON OFFICER SIDE HOSEBED DISCHARGE #1 Officers side hosebed discharge #1
PO00023607 - INJECTION FOAM SYSTEM INSTALLED ON OFFICER SIDE HOSEBED DISCHARGE #2 Officers side hosebed discharge #2
PO00010791 - PUMP INSTALLATION - CUSTOM
PO00009801 - SIDE MOUNT PUMP MODULE
The pump module shall be a self-supported structure mounted independently from the body and chassis cab.

The design must allow normal frame deflection without imposing stress on the pump module structure or side running boards. The pump module shall be securely mounted to the chassis frame rails.

PO00000005 - PUMP MODULE - STEEL CONSTRUCTION
The pump module shall be a welded framework utilizing structural steel components properly braced to withstand the rigors of chassis frame flex.
***SPECIAL: SP00037827 - SIDE MOUNT DUNNAGE AREA
A dunnage area shall be provided above the pump enclosure for equipment mounting and storage. This area shall be furnished with a removable 3/16" tread plate floor and shall be enclosed on the sides.

The inside and outside of the side dunnage area walls shall be painted job color.

NOTE: The size of this storage area may vary when top mounted crosslays, booster reel(s), etc., are specified and located in this area.

Page 276 of 508 ends

16.H

Page 1340 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 109 of 140 PO00011571 - RUNNING BOARD STEPS (NON-AERIALS)
The driver and officer running board steps shall be fabricated of 3/16" tread plate.

The outside edge on each step shall be fabricated with a double break, return flange.

The steps shall be rigidly reinforced with a heavy-duty support structure.

The running boards shall not form any part of the compartment design and shall be bolted into place with a minimum 1/2" clearance gap between any panel to facilitate water runoff.

PO00011575 - STORAGE WELL IN OFFICERS SIDE RUNNING BOARD (FLOATING) A floating storage well, constructed of 1/8" aluminum, shall be recessed into the officer’s side running board.

The storage well shall measure 9" deep x 9" wide x as long as possible between the running board support members.

Drain holes shall be located in the bottom corners to allow water to drain from the storage well.

The front and rear bottom corners of the well shall have an angled face to help the well slide up if it strikes an object.

The entire well shall be a "floating" style that can easily shift up if an object is struck.

PO00026070 - TWO (2) LEVER STYLE STRAPS ON OFFICER'S STORAGE WELL The officer's side running board hose well shall be furnished with lever style straps with 2" webbing to secure the hose stored in the well.

The straps shall be attached to each side of the hose well with stainless-steel footman loops.

PO00011591 - OFFICER'S SIDE WELL - GENERAL STORAGE
The officer's side storage well shall be utilized for general storage of tools or equipment, the well shall be a large as space allows.

PO00011610 - STORAGE WELL IN DRIVERS SIDE RUNNING BOARD (FLOATING) A floating storage well, constructed of 1/8" aluminum, shall be recessed into the driver’s side running board.

The storage well shall measure 9" deep x 9" wide x as long as possible between the running board support members.

Drain holes shall be located in the bottom corners to allow water to drain from the storage well.

Page 277 of 508 ends

16.H

Page 1341 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 110 of 140 The front and rear bottom corners of the well shall have an angled face to help the well slide up if it strikes an object.

The entire well shall be a "floating" style that can easily shift up if an object is struck.

PO00026071 - TWO (2) LEVER STYLE STRAPS ON DRIVER'S STORAGE WELL The driver's side running board hose well shall be furnished with lever style straps with 2" webbing to secure the hose stored in the well.

The straps shall be attached to each side of the hose well with stainless-steel footman loops.

PO00011626 - DRIVER'S SIDE WELL - GENERAL STORAGE
The driver's side storage well shall be utilized for general storage of tools or equipment, the well shall be a large as space allows.

PO00009800 - SIDE MOUNT PUMP PANEL
The pump operator's control panel shall be located on the driver side of the apparatus.

The pump enclosure side panels shall be completely removable and designed for easy access and servicing. ***SPECIAL: SP00020053 - PUMP PANEL APPROVAL DRAWING
A pump panel approval drawing will be provided.

PO00000095 - SIDE MOUNT PANELS - BLACK LINE-X COATED
The left side operator's panel, gauge panel, right side pump panel, and right-side access door shall be fabricated from 1/8" aluminum.

It will also be coated with black Line-X material. The Line-X material shall provide a heavy-duty textured finish.

PO00000128 - VERTICALLY HINGED GAUGE PANEL - SIDE MOUNT A full width, vertically hinged gauge access panel shall be provided at the operator's position.

Chrome plated positive locks shall be provided along with chain holders to prevent the front of the gauge panel from coming in contact with other panels when open.

PO00000132 - OFFICER SIDE VERTICALLY HINGED PUMP ACCESS DOOR - SIDE MOUNT The officer's side pump panel shall be split and vertically hinged to provide complete access to the pump and plumbing on the officer's side of the pump enclosure.

Page 278 of 508 ends

16.H

Page 1342 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 111 of 140 The panels shall be equipped with stainless-steel hinges and secured with push type locks to hold the panels closed.

The drains located on the officer's side panel shall be fastened to the lower panel, which shall be stationary.

PO00010829 - PANEL FASTENERS
Stainless-steel machine screws and lock washers shall be used to hold these panels in position.

The panels shall be easily removable to provide complete access to the pump for major service.

PO00010830 - CAPS AND ADAPTERS SAFETY TETHER - BALL CHAIN All applicable discharge and suction caps, plugs and adapters shall be equipped with chrome plated ball chain and secured to the vehicle.

PO00010832 - PUMP PANEL DISCHARGE/SUCTION TRIM PLATES, HIGH POLISHED A high polished trim plate shall be provided around each discharge port and suction inlet opening to allow accessibility to the respective valve for service and repairs.

PO00010833 - DISCHARGE GAUGE TRIM BEZELS
Each individual discharge gauge shall be installed into a decorative chrome-plated mounting bezel that incorporates valve-identifying verbiage and color labels, unless manufacturer supplied otherwise.

PO00010834 - IDENTIFICATION PLATES
Color coded identification tags shall be provided for all gauges, controls, connections, switches, inlets and outlets.

PO00012157 - PUMP OPERATOR'S PANEL, FULL WIDTH LIGHT SHIELD/STEP The pump operator’s panel shall be equipped with a light shield/step that shall be full width of the control panel and shall be positioned to cover the lights and prevent glare.

The light shield shall be fabricated from tread plate, which shall also serve as a step.

The step shall be a minimum of 8" deep X the width of the pump panel. (Note: On apparatus with lowered style crosslays, the light shield shall be from the back of the crosslays to the rear of the pump house).

The light shield shall be equipped with the following lights:

Page 279 of 508 ends

16.H

Page 1343 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 112 of 140 PO00012171 - TECNIQ E18 LED LIGHTS - LIGHT SHIELD/STEP
Four (4) Tecniq #E18 LED lights.

One (1) light under the operator's panel light shield shall be actuated when fire pump is engaged in addition to the pump engaged light.

PO00012175 - TECNIQ EON 3 LED LIGHTS - OFFICER SIDE PUMP PANEL Four (4) Tecniq Eon, 3-LED illumination lights mounted in horizontal stainless-steel bezels and mounting gaskets.

The lights shall be switched with the main pump panel lights.

PO00012573 - AIR HORN CONTROL BUTTON ON PUMP PANEL
Pump panel air horn actuation button labeled "EVACUATION" in white letters with a red background.

PO00012578 - 3/4" PUMP BY-PASS COOLER ON PUMP PANEL
3/4" Pump cooler (Bypass Line).

PO00012579 - AIR INLET/OUTLET ON RIGHT SIDE PUMP PANEL
Air inlet/outlet chuck (right side panel).

PO00011409 - PUMP PRESSURE & VACUUM TEST PORTS @ PANEL
The pump panel shall be equipped with Vacuum Pressure test plugs to allow for test equipment to monitor pump pressure and vacuum levels.

Chrome plugs and labels shall be provided for the test ports.

PO00011425 - 4-1/2" CLASS ONE, LIGHTED, MASTER PRESS. AND COMPOUND GAUGES One (1) 4-1/2" diameter pressure gauge (labeled: "PRESSURE") and one (1) 4-1/2" diameter compound vacuum gauge (labeled: "INTAKE") shall be provided.

The master gauges shall be Class One and shall be illuminated internally using light emitting diodes, which shall be wired through the pump panel light circuit.

The gauge face shall be white with black numerals.

PO00011432 - 4-1/2" BLUE ILLUMINATED GAUGES - CLASS ONE Both gauges shall be Blue.

Page 280 of 508 ends

16.H

Page 1344 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 113 of 140 PO00011442 - PRESSURE & COMPOUND GAUGE RANGES - SINGLE STAGE All applicable pressure gauges shall have a range of 0 - 400 P.S.I., and the compound gauge shall have a range of -30" - 0 - 400 P.S.I.

PO00025813 - PUMP THIRD PARTY CERTIFICATION - 750 GPM & UP The pump shall be third party performance tested to meet the requirements of NFPA-1901. There will be no exceptions.

PO00007673 - WATER TANK 500-GAL POLY
The water tank shall have a capacity of 500 gallons, constructed from Poly material.

PO00010842 - WATER TANK FILL TOWER POLY
The tank shall have a combination vent and manual fill tower.

The fill tower shall be constructed of 1/2" PT3 polypropylene and shall be a minimum dimension of 8" x 8" outer perimeter.

The fill tower shall be blue in color indicating that it is a water-only fill tower.

The tower shall have a 1/4" thick removable polypropylene screen and a PT3 polypropylene hinged cover.

The capacity of the tank shall be engraved on the top of the fill tower lid. Inside the fill tower there shall be a combination vent/overflow pipe.

The vent overflow shall be a minimum of schedule 40 polypropylene pipe with a minimum I.D. of that is designed to run through the tank and shall be piped to discharge water behind the rear wheels as required in NFPA 1901 so as to not interfere with rear tire traction.

PO00007665 - WATER TANK 4" OVERFLOW & VENT PIPE
The fill tower shall be fitted with an integral 4" I.D. schedule 40 P.V.C. combination overflow/vent pipe running from the fill tower through the tank to a 4" coupling flush mounted into the bottom of the tank to allow water to overflow behind the chassis rear axle.

PO00026282 - WATER TANK 3" SUMP DRAIN W/ 2" PUSH-PULL AT PUMP PANEL A 2" drain valve with a push/pull handle on the pump panel shall be provided.

PO00009185 - INTEGRAL FOAM TANK, 30 GAL. TANK "A"
Included in the total capacity of the water tank, a 30-gallon integral foam storage area shall be built into the water tank.

Page 281 of 508 ends

16.H

Page 1345 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 114 of 140 The foam tank shall have a latched fill tower, properly labeled as the foam fill point.

A valved drain shall be provided.

PO00009188 - INTEGRAL FOAM TANK, 10 GAL. TANK "B"
Included in the total capacity of the water tank, a 10-gallon integral foam storage area shall be built into the water tank.

The foam tank shall have a latched fill tower, properly labeled as the foam fill point.

A valved drain shall be provided.

PO00007589 - CLASS ONE "ITL-40M" LED TANK LEVEL GAUGE - PUMP The water tank shall be equipped with a Class 1, model # ITL-40M, water tank level gauge for indicating water level on the pump operator's panel.

The tank level gauge shall indicate the liquid level on a easy to read LED display and show increments of 1/8 of a tank.

PO00007595 - CLASS ONE WATER LEVEL - 1/4" NPT PRESS TRANS @ BOTTOM TANK The gauge shall use a pressure transducer installed near the bottom of the water tank to determine the correct volume in the tank.

PO00023600 - CLASS ONE RELAY DRIVER
A Class One remote relay module shall be provided to provide outputs for large indicator lights on the side of the vehicle.

PO00007605 - MONSTER WATER LEVEL GAUGE, EA. SIDE OF CAB - WHELEN PSTANK2 A large light water level gauge system shall be provided on both sides of the cab. Each side shall have a Whelen model PSTANK2, LED strip light, surface mounted, behind the rear crew door above the handrail.

The strip light shall indicate the following water levels:
• Green LED cluster Full tank
• Blue LED cluster 3/4 tank
• Amber LED cluster 1/2 tank
• Red LED cluster 1/4 tank
The red LEDs shall burn steady to indicate 1/4 tank and shall start to flash when the water level drops below 1/4 tank. To prevent distraction to drivers, this tank level gauge shall be wired to display only when the park brake is engaged.

Page 282 of 508 ends

16.H

Page 1346 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 115 of 140 PO00007637 - CLASS ONE "ITLF-40M" LED FOAM TANK LEVEL GAUGE - TANK "A" The foam tank shall be equipped with a Class 1, model # ITLF-40M, Itelli-Tank foam level gauge for indicating foam level on the pump operator's panel.

The tank level gauge shall indicate the liquid level on a easy to read LED display and show increments of 1/8 of a tank.
***SHOP NOTE: SR00153140 - FOAM TANK LEVEL GAUGE LABELING The foam tank level gauge labels will read "A" and "B" with no capacity, "A" tank tag color will be red and "B" tank tag color will be green.

PO00007642 - CLASS ONE FOAM LEVEL - 1/4" NPT PRESS TRAN @ BOTTOM TANK "A" The gauge shall use a pressure transducer installed near the bottom of the foam tank to determine the correct volume in the tank.

PO00007651 - CLASS ONE "ITLF-40M" LED FOAM TANK LEVEL GAUGE - TANK "B" The foam tank shall be equipped with a Class 1, model # ITLF-40M, Intelli-Tank foam level gauge for indicating foam level on the pump operator's panel.

The tank level gauge shall indicate the liquid level on a easy to read LED display and show increments of 1/8 of a tank.

PO00007658 - CLASS ONE FOAM LEVEL - 1/4" NPT PRESS TRAN @ BOTTOM TANK "B" The gauge shall use a pressure transducer installed near the bottom of the foam tank to determine the correct volume in the tank.

PO00009849 - FOAMPRO MANUAL DUAL TANK SELECTOR, A & B FOAM TANKS A FoamPro Model 3435-0079, panel mounted, manual dual tank selector valve which provides a water flush when switching between the tank selection shall be provided to allow the use of Class "A" or "B" foam tanks.

This item selection includes one (1) low level sensor and one (1) "Y" strainer for the additional foam tank configuration.

PO00009857 - HALE EZ-FILL FOAM TANK REFILL SYS - DUAL TANK The apparatus shall be equipped with a Hale EZ-Fill foam transfer system for refilling the on-board foam cells.

The system operates by attaching a suction hose to a pre-plumbed panel connection using a positive seal quick connect fitting.

The pickup wand is then placed in the foam concentrate container.

Page 283 of 508 ends

16.H

Page 1347 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 116 of 140 EZ-Fill is an easy-to-operate fixed-mount 12-volt, 5-gpm foam tank refill pump system.

EZ-Fill features push-button smart switch technology.

Just press the “Fill” or “Flush” button for a moment and the unit shall cycle either filling the foam concentrate reservoir or running through a flush cycle.
***SPECIAL: SP00008493 - 1" FOAM TANK DRAIN BEHIND OFFICER SIDE PUMP PANEL A 1" line from the foam tank shall be provided in order to drain foam from the tank. The line shall terminate behind the officer's side pump panel with a quarter turn drain valve.

The foam system shall have a shut off valve at the strainers to service the foam system. The foam shut off valve must be easily accessible to reach from the pump access door.

PO00009795 - APPARATUS BODY GENERAL DESCRIPTION (PUMPER) The body side and compartment assemblies shall be designed and assembled to provide maximum strength and durability under all operating conditions. Special attention shall be taken to minimize corrosion on all fabricated parts and structural members of the body. All bolt-on components shall be provided with a dissimilar metals isolation barrier to prevent electric corrosion.

The body design shall also incorporate removable panels to access spring hangers, rear body mounts and fuel tank sending units. The body assembly shall be an all-welded configuration. The body shall be completely isolated from the cab and pump module structure.

Dimensions used in this specification shall be the general outer dimension taken from a typical line diagram of the apparatus. These dimensions shall not take into account items like material thickness, access panels, doors, and other installed options.
***SPECIAL: SP00008515 - 100" WIDE BODY, 26"/14" DEEP SIDE COMPARTMENTS The fire body shall be 100" wide to provide the maximum amount of usable hose bed and compartment space.

The side body compartments shall be 26" deep in any full depth areas and 14" deep in any split depth areas.

PO00009804 - SWEEP-OUT COMPARTMENTS (NON-AERIALS)
Compartment floors shall be welded to the compartment walls and have a sweep out design for easy cleaning.

Compartments with hinged doors shall have the door opening flanges bend down to produce the sweep-out design.

Compartments with roll-up style doors shall have the external floor flange stepped down to produce a sealing surface for the roll-up doors below the compartment floor.

The sweep out design shall also permit easy cleaning.

Page 284 of 508 ends

16.H

Page 1348 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 117 of 140 PO00010883 - FASTENERS

FASTENERS
All exterior fasteners shall be stainless-steel screws.

NOTE: The use of aluminum pop rivets or self-tapping screws as a trim fastener shall not be acceptable.

PO00010884 - COMPARTMENT LOUVERS
Ventilation between compartments to atmosphere shall be provided and located to avoid water entry into compartments.

PO00010886 - LOUVER FILTERS
To minimize dust and dirt from drafting into the compartments through the compartment louver, each louver shall be equipped with a filter material mounted on the exterior of the louver.

PO00010885 - ACCESS PANELS
Removable access panels shall be provided (if applicable) to access fuel tank sender, electrical junction compartment and rear body mounts.

Protective panels shall be located in the rear compartments providing access to the lights and associated wiring.

The covers shall also serve as protective covers to prevent inadvertent damage to lights or wiring from tools or equipment located in the compartment.

PO00000142 - BODY MATERIAL: 12 GAUGE GALVANNEAL STEEL
The body shall be assembled in fixtures to ensure accurate body dimensions and door openings. The parts used in the construction of the body weldment shall be fabricated from the highest, Grade 12 gauge galvanneal steel (ASTM A653) and will have a coating weight of A-60. After proper alignment is achieved, the body panels shall be spot-welded together to ensure proper weld penetration and then stitch-welded on all exposed seams to minimize distortion of welded assemblies. A full seam weld shall not be used due to the applied heat which shall distort sheet metal and remove the protective coating from the perimeter of the welded area. All seams shall be caulked prior to paint being finished for proper compartment seal.

PO00024374 - BODY SUBFRAME - STEEL
The body sub structure shall be an all-welded configuration utilizing a combination of 3” x 1-1/2” A500 Gr. B structural tubing and A36 structural channel.

Page 285 of 508 ends

16.H

Page 1349 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 118 of 140 The sub structure shall be designed to totally support the full length and width of the body. The structure shall be welded to the body side compartments to incorporate the compartments into an integral part of the body weldment.

All cross tubes of the structure shall be capped, and butt welded at their point of termination to prevent water from lying inside the super structure. The super structure shall be bolted to the sides of the chassis frame at four (4) points. The two (2) forward mounting points shall utilize a spring mount to help isolate the body from chassis deflection.

This design shall provide storage capacity in each side compartment for a minimum of 500 lbs. of equipment, and a minimum of 1000 lbs. of equipment in the rear step compartment. ***SPECIAL: SP00033479 - 61" WIDE FENDER - CUSTOM
The body fender shall be 61" long, this shall allow for the suspension and related components to be contained within the fender, preventing any intrusion into the body compartment storage area. Bodies with notches in the front and/or rear compartment for suspension components are not acceptable. There will be no exceptions. ***SPECIAL: SP00037839 - AIR BOTTLE STORAGE COMPARTMENTS A total of six (6) SCBA air bottle storage compartments 26" deep shall be provided in the rear body fender areas. The driver side compartments shall include one (1) double bottle storage compartment to the rear of the wheels, and (1) single compartment on the forward area. The officer side compartments shall include one (1) double bottle storage compartment to the rear of the wheels, and (1) single compartment on the forward area. Note: The double compartment will have a triangular center partition.

Each storage compartment shall be equipped with a painted door that shall be tied to the "Do Not Move Apparatus" warning system.

Clarification: The fender storage doors will have the Southco ring style latch Southco M1-25-61-28 flush mount stainless-steel latch.

PO00009648 - FENDER WITH STORAGE OPTIONS (CUSTOM)
PO00000147 - MEDIUM PUMPER BODY
***SPECIAL: SP00037893 - 143" DS LOW SIDE / HIGH SIDE
One (1) low side compartment shall be provided forward of the rear wheels, measuring 34" high x 31" wide with an opening of 31" high x 28" wide.

One (1) low side compartment shall be provided to the rear of the rear wheels, measuring 34 high x 33" wide with an opening of 31" high x 30" wide.

One (1) high side compartment shall be provided above the lower compartments and the rear wheels, measuring 34" high x 122" wide with two (2) openings of 31" high x 58" wide each.

Page 286 of 508 ends

16.H

Page 1350 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 119 of 140 ***SPECIAL: SP00037894 - 143" OS LOW SIDE / HIGH SIDE
One (1) low side compartment shall be provided forward of the rear wheels, measuring 34" high x 31" wide with an opening of 31" high x 28" wide.

One (1) low side compartment shall be provided to the rear of the rear wheels, measuring 34" high x 33" wide with an opening of 31" high x 30" wide.

Two (2) equipment compartments shall be provided above the lower compartments, one to each side of the center mounted overhead ladder rack arm. The compartments shall measure 34" high x 50" wide respectively with openings of 31" high x 47" wide respectively.

The officer side lower (EMS) compartment behind the wheel will be provided with a remote unlock push button inside the cab. The button will be located next to the officer side forward facing crew seat and will be labeled Lock\Unlock and illuminated if possible.

The lock switch will be wired HOT to the battery.

A hole will be provided under the compartment door lock to manually unlock the door in the event of an electric lock failure.
***SPECIAL: SP00037896 - FULL HEIGHT BEAVERTAIL STORAGE COMPARTMENTS Each side rear body corner will be equipped with a full height, externally accessed, beavertail storage compartment 68" high x 15" wide x 26" deep at the lower 32" and 14" deep at the upper 36" with a roll up door opening approximately 65" high x 12" wide. The rear 6" of these compartments will be 14" deep to accommodate the 72" wide rear step.
***SPECIAL: SP00037834 - TRANSVERSE LOCKER COMPARTMENT, 24" W X 56" H X 16" A transverse locker compartment shall be provided in front of the pump enclosure, one (1) each side measuring 24" wide x 56" high x 16" deep / transverse above the frame rails with a door opening of 17" wide x 54" high.

The compartment shall be transverse over the frame rail.

There will be a 5" forward door post to clear the telescoping lights. The compartment will have a 1" thick door held open by gas struts with a D-ring handle.

Note: The transverse portion of this compartment shall have a 6" recessed area in the center 34" to accommodate cross lay plumbing.
***SPECIAL: SP00037898 - INTERMEDIATE REAR STEP COMPARTMENT An intermediate rear compartment shall be provided above the rear step compartment. The compartment shall be approximately 26" deep x as wide and tall as possible.

Page 287 of 508 ends

16.H

Page 1351 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 120 of 140 The compartment shall include a smooth aluminum top hinged door with two (2) thumb latches and gas shock stay arms. The door shall include chevrons to match the color and design of the specified rear chevrons.

The door shall be wired into the "do not move circuit". ***SPECIAL: SP00037899 - ISOLATED REAR STEP COMPARTMENT An isolated rear step compartment measuring approximately 36" high x 48" wide x 32" deep with a door opening of 34" high x 45-1/2" wide shall be provided at the rear of the apparatus.

PO00000200 - REAR STEP COMPARTMENT - FULL SIDE WALLS
The rear step compartment shall have full side panels which will isolate the storage area from the side body compartments.

PO00000203 - REAR STEP COMPARTMENT - ROLLUP DOOR
The rear step compartment shall be equipped with a roll up style door.

PO00024176 - REAR BODY DOOR FINISH - SATIN
The rear body door shall have a satin finish.

PO00024179 - REAR BODY DOOR RAIL FINISH - SATIN
The rear body door rails shall have a satin finish.
***SPECIAL: SP00037897 - KEYED DOOR LOCKS, HINGED OR ROLL-UP DOORS Thirteen (13) compartment door(s) shall be equipped with keyed locking door latches (six (6) compartment doors on each side, plus the rear step compartment roll up door). Two keys shall be furnished for each lock and shall be labeled to indicate the correct match.

Twelve (12) of the specified door lock cylinders shall be equipped with a #1250 key, and the officer side lower rear body compartment shall be equipped with a #751 key.

In additional, the officer’s side lower rear compartment shall be equipped with an electronic lock provided by the roll up door manufacturer. The switch to unlock the compartment door shall be located inside the cab, in the rear crew area next to the fold down seat on the officer’s side adjacent to the back wall.

PO00010936 - ROLL-UP DOORS
Roll-up doors shall be provided on all compartments.

The roll-up doors shall be constructed from aluminum extruded slats which shall have a flexible seal between each slat for proper sealing of the door.

Page 288 of 508 ends

16.H

Page 1352 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 121 of 140 A synthetic rubber seal shall be provided at each side, top and bottom edge of the door to prevent entry of dirt into the compartment.

The door shall be equipped with a lift bar style latch mechanism which shall latch at the bottom of the door mounting extrusion.

The roll-up door assembly shall be furnished with a spring-loaded, counterbalance assembly to assist in door actuation.

All running board and high side compartments shall be equipped with roll-up doors.

PO00000286 - AMDOR ROLL-UP DOORS, PAINTED FINISH
The roll-up doors shall be made of Amdor brand. The doors shall be painted to match the required color of the fire department.

PO00009734 - PAINTED ROLLUP DOORS - PAINTED CURTAIN, TOP GUTTER The top gutter and side frames shall be painted to match the required color of the fire department.

PO00000288 - KEY MODEL #1250
The specified door lock cylinder shall be equipped with a #1250 key.

PO00024098 - REAR COMPARTMENT DOOR MANUFACTURER - AMDOR The rear compartment door brand shall be Amdor.

PO00010859 - COMPARTMENT TOPS
Compartment ceilings shall be a fully welded design as part of the body construction process.

Compartment designs that do not have a welded in ceiling and utilize the stepping surface overlay as the ceiling shall not be acceptable. {No Exceptions}
The top of the welded in compartment ceiling shall be overlaid with tread plate to provide an NFPA compliant stepping surface.

There will be no exceptions.

PO00010862 - REAR BODY PANEL
The rear body panel shall extend the full width between the body side compartments.

This panel shall be full height from the rear step to the hose bed floor.

No part of the rear panel shall be attached to the booster tank.

Page 289 of 508 ends

16.H

Page 1353 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 122 of 140 The rear body panel material shall be tread plate as standard.

If Chevron striping is specified for the rear of the body then smooth aluminum shall be utilized.

PO00009806 - STAINLESS DOOR SILL PROTECTORS INSIDE ALL BODY A 90 deg angle door sill protector, fabricated from 18 gauge brushed finish stainless-steel shall be installed on the bottom external edge of each body compartment door opening to help protect this area from paint chipping.

PO00012483 - TREAD PLATE OVERLAY, FRONT OF SIDE COMPARTMENTS (WRAP AROUND) The front face of the side compartments, next to the driver and officer side pump panels shall be overlaid with tread plate full height protection.

The protection panel shall cover the entire front face of the compartment and shall wrap around the corner to the door opening.

PO00000290 - BODY RUB RAILS, TREAD PLATE
Sacrificial, tread plate, rub rails shall be mounted at the base of the body, extending outward a minimum of 3/4", downward 2", and flange inward 1". The rub rails shall extend the full length of the main body and out to the rear step or wrap around the corners. Rub rails shall be bolted to the body from the bottom side of the compartment area, so that it does not damage the body side panels on initial impact and providing for ease of replacement.

PO00009797 - ALUMINUM WHEEL WELL LINERS
The body wheel wells shall be provided with fully removable bolt-in aluminum fender liners. The wheel well liners shall extend from the outer wheel well body panel into the truck frame. The completely washable wheel well liners shall be designed to protect the front and rear compartments and main body supports from road salts, dirt accumulation and corrosion.

PO00009703 - POLISHED ALUMINUM FENDERETTES, SINGLE AXLE BODIES The rear fenders shall be equipped with easily replaceable bolt-in polished aluminum fenderettes. The fenderettes shall be equipped with a rubber gasket molding between the body panel and the fender. ***SPECIAL: SP00008585 - I ZONE BRACKETS
A pair of I-Zone brackets will be installed on the beavertails of the unit. The brackets will be fabricated from Austin Hardware folding steps. When in the closed or opened position, the brackets will not extend beyond the side of the body.

The brackets will be installed below the rear scene lights one on each side. The bottom of the mounting plates will be 49" above the top surface of the rear step.

Page 290 of 508 ends

16.H

Page 1354 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 123 of 140 PO00010934 - REAR MUD FLAPS
Heavy duty mud flaps shall be provided behind the rear wheels.

PO00000207 - RECESSED REAR STEP - 12 D X 72 W + 4 D X 100 W The rear step shall be a total of 16" deep, 12" recessed, and 4" extended. The recessed area of the step shall be 12" deep. The step must be recessed between the rear portion of the rear side compartments. The step shall be 72" wide in the recessed area and 100" wide in the extended area. The step shall be fabricated from 3/16" tread plate and shall be rigidly reinforced. The recessed design of the rear step shall reduce the rear side compartment depth to 14" deep in the rearmost 12" wide area of the compartment. The rear edge of the step shall be designed to accommodate the rear clearance lights. It will also be recessed for protection in the step reinforcement channel. The step shall be bolted into place with a minimum 1/2" clearance gap between the step and rear body panel.

The rear body beavertail area shall be furnished with a squared off appearance to maximize the available compartment area. The squared off appearance also provides additional support to the rear step structure.

The beavertail panels shall be assembled in conjunction with the rear body corner panels. This assembly shall provide a vertical mounting surface for taillights at the rear most portion of the body. In addition, storage space is also added to the assembly. The beavertails insides shall be furnished with tread plate overlays. ***SPECIAL: SP00008795 - INTERMEDIATE REAR STEP, 8" X FULL WIDTH An eight (8) inch deep formed intermediate rear step will be provided as an integral part of the rear body. The traffic advisor will be flush mounted into the rear body sheet above the intermediate rear step compartment.

PO00011555 - GRAB RAILS, KNURLED ALUMINUM EXTRUSION
All handrails shall be 1-1/4" outer diameter, knurled bright anodized aluminum extrusion, designed to meet NFPA 1901 requirements.

Molded gaskets shall be installed between the handrail stanchion castings and body surfaces to prevent electrolytic reaction between dissimilar metals and to protect paint.

Grab rails shall be provided at the following specified locations.

Additional grab rails shall be provided adjacent to any additional steps specified to comply with NFPA 1901.

PO00011563 - TWO (2) VERTICAL RAILS ON REAR
Two (2) vertical rails shall be mounted on the rear edge of the beavertails, one (1) each side. ***SPECIAL: SP00037887 - TWO (2) 12" HORIZONTAL HANDRAILS REAR TOP OF BODY Two (2) 12" horizontal handrails shall be provided and installed one (1) on each side at rear top of body.

Page 291 of 508 ends

16.H

Page 1355 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 124 of 140 PO00011569 - HANDRAIL ABOVE PUMP PANEL, EACH SIDE
Two (2) horizontal handrails shall be mounted above each pump panel, (1) each side.

PO00011511 - INNOVATIVE CONTROLS LIGHTED STEP(S), BODY FRONT, DRIVER SIDE Innovative Controls large lighted folding step(s), with a textured chrome plate finish, shall be provided on driver side body front to provide NFPA compliant access (maximum 18” height between steps) to an upper horizontal walking surface (compartment cap, dunnage area, fabricated step, or upper body compartments).

PO00011496 - INNOVATIVE CONTROLS LIGHTED FOLDING STEP(S), BODY REAR DRIVER SIDE Innovative Controls large lighted folding step(s), with a textured chrome plate finish, shall be provided on driver side body rear to provide NFPA compliant access (maximum 18” height between steps) to an upper horizontal walking surface (compartment cap, dunnage area, fabricated step, or upper body compartments).

PO00011502 - NO FOLDING STEP(S), BODY REAR, OFFICER SIDE No folding steps shall be provided in this location.

PO00000317 - PAINTED REAR TOW EYES, BELOW BODY
Two (2) painted tow eyes shall be furnished on the rear of the vehicle. The tow eyes shall be made from plate steel and shall be bolted directly to the chassis frame rails with grade 8 bolts. The tow eyes will extend below the body. The tow eyes shall be smooth and free from sharp edges. They will have a minimum eyelet hole of 2-1/2". The tow eyes shall be painted.

PO00000217 - STANDARD BED - STANDARD COMPT CAPS (72")
The hose bed shall be located directly above the booster tank and be free from all sharp objects such as bolts, nuts, and so on, in avoidance of damage to a fire hose. For added strength, the hose bed side walls shall be approximately 2" thick, providing a mounting surface for devices such as warning and scene lights. The inner hosebed side walls shall be brushed aluminum panels, which will help prevent damage to painted surfaces when the hose is deployed. The front wall shall be flanged inward 2" with a 1" downward return, providing additional rigidity to the front wall.

PO00000226 - NFPA MINIMUM HOSEBED CAPACITY
The hose bed shall provide a minimum of 30 cubic feet hose storage area for 2-1/2" or larger fire hose in order to meet NFPA-1901 minimum pumper hose storage requirement. The apparatus weight analysis shall be based on 800’ of 2-1/2" hose, unless otherwise specified. If the hose load carried exceeds this minimum, the purchaser should advise the manufacturer prior to contract so that adequate chassis carrying capacity can be provided.

Page 292 of 508 ends

16.H

Page 1356 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 125 of 140 PO00000228 - HOSEBED FLOORING - ALUMINUM SLATS
Flooring is to be constructed from extruded aluminum and have proper spaces for ventilation purposes. The flooring shall be smooth and free from sharp edges to avoid any hose damage. The hose bed floor shall be removable, providing access to the inner body framework. ***SPECIAL: SP00037836 - THREE (3) - 1/4" ADJUSTABLE HOSEBED PARTITIONS W/ NOTCHES Three (3) fully adjustable 1/4" aluminum hose bed partitions shall be provided. The partition shall be easily adjustable by channels, located at the front and rear of the hose bed. The partition shall be removable for access to the booster tank.

Each partition shall include an 8” deep notch on the bottom section of the partition at the hosebed wall to allow for ease of connection. Notches will be as high as the lower Unistrut.

PO00009735 - HOSEBED BLANK PANEL
A full width divider shall be installed in the hose bed located approximately 2" beyond the end of the water fill tower.

This divider shall be constructed of smooth aluminum and shall be fixed.

The adjustable hose bed dividers shall be installed up to this divider with the adjustment tracking attached to the fixed divider.

PO00009731 - TUBING REINFORCEMENT ON PARTITION(S) - 1-1/4" The top and rear edge of each of the hose bed partitions shall have a 1-1/4" integral tubing reinforcement welded on for additional support.

PO00009732 - HOSE PARTITION HANDHOLD CUTOUTS
The hose bed partition(s) shall have a vertical handhold cutout at upper rear edge of the partition. ***SPECIAL: SP00037868 - HOSEBED COVER - TREADPLATE COVER WITH FIXED CENTER DIVIDER An aluminum tread plate hose bed cover shall be mounted to the side body flanges utilizing a full-length stainless-steel hinge on each side. The cover shall be constructed of 3/16” aluminum tread plate with aluminum extrusion frame. The cover shall be supported by a fixed center partition which shall be 1-1/2” higher than the side body flanges to allow water runoff. The center hose bed fixed partition shall be notched at the lower rear to allow hose to be packed around the partition. The notch shall be 12” high X 6” deep.

Handles shall be provided at the rear for lifting. Gas springs and cables shall be provided at the front to hold open the doors. Note: The gas shocks for the hose bed covers shall be as strong as possible.

Switches shall be provided on each side cover, which shall be tied into the "Do Not Move Apparatus When Light Is On" warning light in the cab.

Page 293 of 508 ends

16.H

Page 1357 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 126 of 140 A two (2) piece hinged access door shall be provided over the water tank fill tower area to allow access to the fill tower when the hose bed cover is in the closed position. The access door shall be hinged to the front to help prevent the door from opening when the apparatus is in motion. The split doors shall allow the driver side door to be opened when the ladder rack is in the stowed position. A single forward hinged flip up door will be provided in the driver's side door above the water fill tower.

There shall be an Amdor Luma bar light under the body flange in the water tower compartment.

Hose bed aluminum tread plate doors shall be provided with D-handles at the front and rear to assist with lifting.

The stay-open arms shall be provided with sleeves in place of release knobs. ***SPECIAL: SP00037835 - VINYL FLAPS AT REAR EDGE OF TREAD PLATE COVER W/ POSTMAN STRAPS Two (2) vinyl flaps at the rear of the tread plate hose bed cover. They shall be secured to the hose bed cover with quarter turn fasteners and secured at the bottom with postman straps.

PO00000254 - VINYL MATERIAL COLOR - BLACK
The vinyl material shall be black in color.

PO00009678 - ZICO "SINGLE ARM" HEAVY DUTY HYDRAULIC LADDER RACK (OFFICER SIDE) A hydraulically actuated, single arm, swing down ladder rack, for use with ladders that have a combined weight of approximately 500lbs., shall be provided. The ladders shall be stored horizontally, directly above the officer side compartments. The ladders shall be lowered and raised by means of a hydraulic actuator.

The ladders shall be stored on an 86" long cradle to retain the ladders with two (2) ladder retaining brackets mounted to hold the ladders with the rack down. The cradle shall be equipped with a forward and rear bumper stop, which shall be designed to contact the upper portion of the body to stabilize the ladder rack in the travel position.

The arm mechanism shall be constructed from 2" X 3" rectangular steel tubing arms with a square tubing framework to support the ladder storage angles. The pivot points of the arms shall be mounted with pins through a rigid aluminum casting to maintain structural integrity.

The actuator switch and power on/off switch for the ladder rack shall be located on the officer side pump panel area in an enclosed housing, to provide the operator full view of the rack during the raising or lowering operation. A warning alarm shall activate when the rack is in motion and shall be installed on the officer side rear body panel. An interlock system shall be provided whereas if any hinged compartment door on the officer side of the body is open, the rack shall not operate.

A flashing warning light labeled: "Do Not Move Apparatus When Light Is On", shall be provided on the cab dash to indicate when the rack is not in the raised travel position.

Page 294 of 508 ends

16.H

Page 1358 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 127 of 140 The forward and rear ends of the ladder rack shall be equipped with flashing lights to warn when the rack is down. The lights shall be amber on the front and red on the rear and shall automatically activate when the rack is not locked in the travel position.

An automatic lock shall be provided for the ladder rack in the nested position that shall automatically engage when the ladder rack is nested.

PO00009682 - ZICO SINGLE ARM RACK - LOCATED IN CENTER POSITION The specified single arm ladder rack shall be located in the center mounting position on the body side.

This mounting shall split the specified high side compartment into two separate compartments, and reduce the overall width by 17".

The 17" void shall be taken from the center section of the high side compartment, and two (2) equally sized doors shall be installed on the high side compartments.

PO00009684 - SINGLE ARM LADDER RACK - PAINTED HYDRAULIC COVER A painted cover shall be installed to cover the hydraulic cylinder actuator arm. The cover shall be painted job color of the body and shall be actuated automatically with operation of the ladder rack.

PO00008997 - DUO-SAFETY 900-A 24' 2-SECTION EXTENSION LADDER (ALUMINUM) A Duo-Safety series 900-A, 24', aluminum, two (2) section extension ladder shall be provided.

PO00009017 - DUO-SAFETY 775-A 14' ROOF LADDER W/ FOLDING HOOKS (ALUMINUM) A Duo-Safety series 775-A, 14', aluminum, straight roof ladder with folding hooks shall be provided.

PO00000401 - DUO-SAFETY 585-A 10' FOLDING ATTIC LADDER (ALUMINUM) A Duo-Safety series 585-A, 10', folding, aluminum, attic ladder shall be provided.

PO00019830 - 1/2 DEPTH ADJUSTABLE SHELF DESCRIPTION - RESCUE Compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2” upward bend at front and rear, and side supports. Shelving shall be vertically adjustable with spring nuts in aluminum strut channel.

Half depth adjustable shelves shall be located as indicated at each compartment description.

PO00019874 - 1/2 DEPTH ADJUSTABLE SHELF(S) LOCATED R-4
Located in the right side compartment #4

Page 295 of 508 ends

16.H

Page 1359 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 128 of 140 PO00019887 - ADJUSTABLE SHELF DESCRIPTION - RESCUE
Compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2” upward bend at front and rear, and side supports. Shelving shall be vertically adjustable with spring nuts in aluminum strut channel.

Adjustable shelves shall be located as indicated at each compartment description.

PO00019932 - ADJUSTABLE SHELF(S) LOCATED R-5
Located in the right side compartment #5
PO00019935 - ADJUSTABLE SHELF(S) LOCATED REAR COMPARTMENT Located in the rear compartment
PO00019997 - 250#, FLOOR MOUNTED, ROLLOUT TRAY
Slide out floor mount compartment shelving shall be constructed of 3/16” brush finish aluminum with a 2" upward bend at front and rear, and side supports attached to #250 rated slides. Slide out floor mount shelving shall have gas shocks to hold the tray in and out.

Slide out floor mount shelving shall be as indicated at each compartment description.

PO00020028 - ROLLOUT TRAY, LOCATED L-2
Located in the left side compartment #2
PO00020031 - ROLLOUT TRAY, LOCATED L-5
Located in the left side compartment #5
PO00020035 - ROLLOUT TRAY, LOCATED R-2
Located in the right side compartment #2
PO00020041 - 250# ROLLOUT TRAY, LOCATED REAR COMPARTMENT Located in the rear compartment
PO00009876 - TURTLE TILE MATERIAL ON ALL COMPARTMENT FLOORS Turtle Tile brand floor material shall be installed on all compartment floors.

The Turtle Tile shall be custom installed to provide full floor coverage.

Page 296 of 508 ends

16.H

Page 1360 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 129 of 140 PO00009869 - FLOORING MATERIAL ON SHELF(S) OR TRAY(S)
Floor matting material shall be provided on the noted quantity of specified shelves or roll-out trays.

PO00009870 - FLOORING MATERIAL COLOR (BLACK IS DEFAULT) The compartment flooring color shall be black.
***SPECIAL: SP00008663 - TOOL BOARDS ON REAR WALLS OF COMPARTMENTS 1/4" smooth aluminum tool boards shall be provided on the rear walls for mounting of loose equipment in the specified compartment. The tool boards will be as wide, wall to wall and as tall, floor to ceiling as possible.

The tool boards shall be located in the following compartment/s:
• Driver side upper front
• Driver side upper rear
PO00010847 - GENERAL PAINT DESCRIPTION
The apparatus body shall be painted with Sikkens paint product. The paint process shall meet or exceed current state regulations concerning paint operations. Pollution control shall include measures to protect the atmosphere, water, and soil. Contractor shall, upon demand, provide evidence that the manufacturing facility is in compliance with State EPA rules and regulations.

The exterior shall have no mounted components prior to painting to assure full coverage of metal treatments and paint to the exterior surfaces of the body. Any vertically or horizontally hinged smooth-plate compartment doors shall be painted separately to assure proper paint coverage on body, door jambs and door edges.

Paint process shall feature Sikkens high solid LV products and be performed in the following steps:
• Corrosion Prevention - all aluminum surfaces shall be pre-treated with the Alodine 5700 conversion coating to provide superior corrosion resistance and excellent adhesion of the base coat. • Sikkens Sealer/Primer LV - acrylic urethane sealer/primer shall be applied to guarantee excellent gloss hold-out, chip resistance and a uniform base color.
• Sikkens High Solid LVBT650 (Base coat) - a lead-free, chromate-free high solid acrylic urethane base coat shall be applied, providing excellent coverage and durability. A minimum of two (2) coats shall be applied. • Sikkens High Solid LVBT650 (Clear coat) - high solid LV clear coat shall be applied as the final step in order to ensure full gloss and color retention and durability. A minimum of two (2) coats shall be applied.

Any location where the material is penetrated after painting, for the purpose of mounting steps, hand rails, doors, lights, or other specified components shall be treated at the point of penetration with a corrosion inhibiting pre-treatment (ECK Corrosion Control). The pre-treatment shall be applied to the aluminum sheet metal or aluminum extrusions in all locations where the aluminum has been penetrated. All hardware used in mounting steps, hand rails, doors, lights, or other specified components shall be individually treated with the corrosion inhibiting pre-treatment.

Page 297 of 508 ends

16.H

Page 1361 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 130 of 140 After the paint process is complete, the gloss rating of the unit shall be tested with a 20 degree gloss meter.

Coating thickness shall be measured with a digital MIL gauge and the orange peel with a digital wave scan device.

PO00010848 - GENERAL PRIMER & PREP DESCRIPTION - PUMPER All exposed welds shall be ground smooth for final finishing of areas to be painted.

The compartments and doors are totally degreased and phosphatized.

After final body work is completed, grinding (36 and 80 grit), and finish sanding shall be used in preparation for priming.

PO00010849 - GENERAL FINISH PAINT DESCRIPTION
The body shall be finish sanded and prepared for final paint.

Upon completion of final preparation, the body shall be painted utilizing the highest quality, state of the art, low V.O.C., polyurethane base paint.

Finish paint shall be applied in multiple coats to ensure proper paint coverage with a high gloss finish.

PO00010852 - CUSTOM FINISH PAINT & PREP
The applicable areas of the cab shall be finish sanded and prepared for final paint.

Upon completion of final preparation, the cab shall be painted utilizing the highest quality, state of the art, low V.O.C., polyurethane base paint.

Finish paint shall be applied in multiple coats to ensure proper paint coverage with a high gloss finish.

PO00010851 - CUSTOM CAB PRIMER & PREP
The cab primer shall be a two (2) stage process.

First stage shall be a coating with a two-part component, self-etching, and corrosion resistant primer to chemically bond the surface of the metal for increased adhesion.

Second stage shall be multiple coats of a catalyzed, two component, polyurethane primer applied for leveling of small imperfections and topcoat sealing.

PO00011730 - CUSTOM CAB UNDERSIDE PAINT - JOB COLOR
The exposed areas under the cab shall be painted job color to match the exterior cab.

On two tone cabs, this shall match the primary color.

Page 298 of 508 ends

16.H

Page 1362 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 131 of 140 PO00023873 - CUSTOM CAB EXTENSION PAINT
PO00010853 - CUSTOM CAB BUFFING & FINISH
The exposed exterior finish of the cab shall be buffed and detailed.

PO00004569 - CUSTOM CAB INTERIOR PAINT - TEXTURED GRAY
The exposed interior metal surfaces of the cab shall be finish painted with a textured gray paint.

PO00010850 - BODY BUFFING & FINISH - PUMPER
The visible and exposed areas of the body shall be buffed and detailed.

PO00004547 - INSIDE/UNDERSIDE BODY PAINTED JOB COLOR - PUMPER The inside and underside of the complete body assembly shall be painted job color using a Sikkens paint system, prior to installation of the body on the chassis or torque box.

PO00004548 - JOB COLOR COMPARTMENT INT W/SPATTER PAINT - PUMPER/TANKER The interior of the compartments shall be finish painted job color with a scuff resistant webbing type paint of a contrasting color applied over the painted surfaces.
***SPECIAL: SP00032528 - FENDER COMPARTMENT INTERIOR-BLACK SPEEDY LINER The interior of the fender storage compartments including the cylinder/equipment shelves/brackets shall be finish painted with Black Speedy Liner paint to provide a protective finish.

PO00004566 - SINGLE COLOR CUSTOM CAB PAINT SCHEME - RED FLNA 3225 (E-1 RED) The cab exterior shall be finish painted with Sikkens paint system, single color, to match purchaser's furnished paint code.

PO00004558 - PUMPHOUSE & PLUMBING PAINTED JOB COLOR - PUMPER The pump enclosure and pump/plumbing within the pump enclosure shall be painted job color to match the primary color of the body.

PO00004555 - SINGLE COLOR BODY PAINT SCHEME - PUMPER - RED FLNA 3225 (E-1 RED) The body paint finish shall be Sikkens paint system in a single color to match customer furnished paint codes and requirements.

Page 299 of 508 ends

16.H

Page 1363 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 132 of 140 PO00010855 - PINT OF TOUCH-UP PAINT
One (1) pint of each exterior color paint for touch-up purposes shall be supplied when the apparatus is delivered to the end user.

PO00010854 - FINALIZATION & DETAILING - PUMPER
Prior to delivery the vehicle, the interior and exterior be cleaned and detailed.

The finalization process detailing shall include installation of NFPA required labels, checking fluid levels, sealing and caulking required areas of the cab and body, rust proofing, paint touch-up, etc PO00004577 - CUSTOM CHASSIS JOB COLOR FRAME RAILS
The chassis frame rails, suspension, axles, and drivelines (with the exception of any PTO drivelines which shall be safety yellow) shall be painted with polyurethane paint to match the body color code prior to the installation of any air lines or electrical system to ensure serviceability.

PO00004588 - CUSTOM LETTERING ON FRONT CAB DOORS
Lettering provided on the driver's and officer's cab doors shall be custom height per Fire Department and engineering design.

PO00004583 - GOLDLEAF W/ DROP SHADOW LETTERING ON FRONT CAB DOORS Gold leaf, "Real Gold" vinyl, with drop shadow lettering shall be provided on the cab driver's and officer's doors per the fire department requirements.

The design of the lettering on the cab doors shall be designed to fit in the 496 sq. inches available.

PO00023730 - FRONT CAB DOOR TEXT LINE 1 - CITY OF HEMET PO00023731 - FRONT CAB DOOR TEXT LINE 2 - FIRE DEPARTMENT PO00004681 - FRONT CAB DOOR LETTERING TOP LINE ARCED
PO00004610 - CUSTOM LETTERING ON REAR CAB DOOR
Lettering provided on the front of cab shall be custom height per Fire Department and engineering design.

PO00009617 - GOLDLEAF W/ DROP SHADOW LETTERING ON REAR CAB DOORS Gold leaf, "Real Gold" vinyl, with drop shadow lettering shall be provided on the cab driver's and officer's doors per the fire department requirements.

The design of the lettering on the cab doors shall be designed to fit in the 496 sq. inches available.

Page 300 of 508 ends

16.H

Page 1364 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 133 of 140 PO00023732 - REAR CAB DOOR TEXT LINE 1 - #
PO00023733 - REAR CAB DOOR TEXT LINE 2 - PARAMEDIC
PO00009624 - CUSTOM LETTERING ON FRONT OF CAB
Lettering provided on the front of cab shall be custom height per Fire Department and engineering design.

PO00004605 - GOLDLEAF W/ DROP SHADOW LETTERING ON FRONT OF CAB Gold leaf, "Real Gold" vinyl, with drop shadow lettering shall be provided on the front of the cab per the fire department requirements.

The design of the lettering on the front of the cab shall be designed to fit in the 167 sq. inches available.

PO00023734 - FRONT OF CAB TEXT - HEMET
PO00004625 - SCOTCH-LITE W/ DROP SHADOW LETTERING ON REAR BODY PANEL Scotch-Lite with drop shadow lettering shall be provided on the rear body panel per the fire department requirements.

The design of the lettering on the rear of the body shall be designed to fit in the 167 sq. inches available.

PO00023737 - REAR BODY TEXT LINE 1 - HMT
PO00023738 - REAR BODY TEXT LINE 2 - #
PO00023739 - REAR BODY TEXT LINE 3 - DATA ERROR
PO00004632 - CUSTOM LETTERING ON REAR BODY
Lettering provided on the rear body panel shall be custom height per Fire Department and engineering design.

PO00004635 - SCOTCH-LITE W/O DROP SHADOW LETTERING ON CAB ROOF Scotch-Lite without drop shadow lettering shall be provided on the cab roof per the fire department requirements.

The design of the lettering on the cab roof shall be designed to fit in the 2500 sq. inches available.

PO00004644 - 30" LETTERING ON CAB ROOF
Lettering provided on the cab roof shall be 30" high per Fire Department and engineering design.

Page 301 of 508 ends

16.H

Page 1365 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 134 of 140 PO00023740 - CAB ROOF TEXT LINE 1 - HMT #
PO00023741 - CAB ROOF TEXT LINE 2 - DATA ERROR
PO00011791 - 6" SCOTCH-LITE STRIPE ON CAB AND BODY - PUMPER/TANKER A six (6) inch high "Scotch-Lite" stripe shall be provided.

The stripe shall be applied on a minimum of 60 percent of each side of the unit, 60 percent on the rear of the unit and 40 percent on the front of the unit.

The Scotch-Lite stripe layout shall be determined by the Fire Department.

PO00009526 - BLACK SCOTCH-LITE
The Scotch-Lite shall be black in color.

PO00009496 - 6" SCOTCH-LITE "Z" IN STRIPE
A six (6) inch simple "Z" effect shall be incorporated into the Scotch-Lite scheme on the body.

Final layout of this configuration shall be determined by the Fire Department. ***SPECIAL: SP00037912 - REAR CHEVRON PINSTRIPING
1/4" black vinyl pinstripes shall be provided on the front bumper chevron and rear chevron and shall overlap the chevron seams where the two colors meet. Clear tape shall be applied over the pinstriping.

PO00009536 - REAR CHEVRON STRIPING

REAR CHEVRON STRIPING
PO00012448 - ENTIRE REAR
The entire rear of the truck shall be covered with alternating strips of reflective striping.

PO00009540 - 6" FULL REAR ORALITE CHEVRON STRIPING
The striping shall be 6" Oralite reflective striping.

PO00024628 - RED & YELLOW ORALITE V98
The Oralite V98 reflective tape shall be #12 red and #18 yellow in color.

Page 302 of 508 ends

16.H

Page 1366 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 135 of 140 PO00026066 - MISCELLANEOUS EQUIPMENT
The following equipment shall be mounted as specified or as loose equipment provided with the completed apparatus at the time of delivery:

PO00011822 - ROAD SAFETY KITS
A road safety kit shall be furnished with the following equipment:
• 2 1/2 lb. B-C fire extinguisher
• Triangle safety reflectors.

PO00009970 - ZICO SCBA CYLINDER BRACKET, MOUNTED AS DIRECTED A Zico SCBA bottle brackets mounted as directed by the fire department.

PO00000518 - TWO (2) ZICO #SAC-44 FOLDING WHEEL CHOCKS - FD MOUNTING Two (2) Zico model #SAC-44 folding wheel chocks shall be provided and mounted as directed by the fire department.

PO00023664 - KME WARRANTY, STARTING ON IN-SERVICE DATE
Warranty coverage by KME will begin when the customer places the unit in service. This date may not exceed 60 days from the date of delivery to the customer.

The Customer must email [email protected] within 60 days of delivery, or the warranty start date will default to the original delivery date.

PO00022810 - 1 YEAR WARRANTY - BASE WITH CUSTOM CHASSIS The proposed vehicle includes a one (1) year new vehicle warranty, upon delivery and acceptance of the vehicle.

The warranty will ensure that the vehicle has been manufactured to the proposed contract specifications and will be free from defects in material and workmanship that may appear under normal use and service within the warranty period. The warranty may be subject to different time and mileage limitations for specific components and parts. This warranty is issued to the original purchaser of the vehicle.

The warranty will not apply to tires, batteries, or other parts or components that are warranted directly by their manufacturers. The warranty will not apply to routine maintenance requirements as described in the service and operators manual. No warranty whether express, implied, statutory or otherwise including, but not limited to any warranty of merchantability or fitness for purpose will be imposed.

All components and parts of the vehicle are warranted for a period of one (1) year from acceptance of the vehicle unless excluded elsewhere in this warranty or described as having longer time limitations.

Page 303 of 508 ends

16.H

Page 1367 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 136 of 140 PO00022661 - 5 YEAR CUMMINS BASE WARRANTY
The proposed unit will be equipped with a Fire Service rated engine, which will come furnished with a five (5) year Engine Manufacturer's warranty. A copy of the manufacturer's warranty will be supplied to define additional details of the warranty provisions.

PO00022665 - 5 YEAR ALLISON EVS TRANSMISSION WARRANTY
The proposed Allison transmission will be provided with a five (5) year warranty. A copy of the Allison transmission warranty will be supplied to the purchaser to define additional details of the warranty provisions.

PO00022980 - 3 YEAR COOLING SYSTEM WARRANTY - CUSTOM
Kovatch Mobile Equipment (KME) warrants all Cooling System Equipment components used in the construction of KME Fire Apparatus against defects and workmanship provided the apparatus is used in a normal and reasonable manner. This warranty is extended only to the original user-purchaser for a period of three (3) years from the date of delivery/acceptance to the original user-purchaser, whichever occurs first.

This warranty applies to both purchased and fabricated, manufacturer supplied coolant system components and is not provided in lieu of any Vendor provided warranties. All coolant system components provided by the engine manufacturer are covered by the engine manufacturer’s warranty only.

PO00022669 - LIFETIME FRAMERAIL WARRANTY
The proposed KME custom chassis frame and cross members will be warranted to the original purchaser for the life of the vehicle. A copy of KME's frame rail warranty will be supplied to define additional details of the warranty provisions.

PO00022978 - SHEPPARD STEERING GEAR STANDARD - THREE YEAR WARRANTY The proposed Sheppard steering gear will be warranted for a period of three (3) years from the first date of service or 150,000 miles (241,401 kilometers), whichever occurs first. The product will be free from defects in material and workmanship under normal use in applications approved in advance by Sheppard.

PO00022956 - 5 YEAR MERITOR 160 SERIES TANDEM AXLE REAR - WARRANTY The Meritor axle/s shall be provided with a five (5) year warranty. The first two (2) years shall be parts and labor; the remaining three (3) years shall be parts only. Wheel seals, gaskets and wheel bearings shall be covered for one year. A copy of Meritor's warranty shall be supplied to define additional details of the warranty provisions. Vehicles that operate full or part-time outside the United States and Canada shall have a one (1) year, parts only warranty.

PO00022681 - 3 YEAR MERITOR ABS - WARRANTY
The Meritor ABS shall be provided with a three (3) year warranty, parts and labor. A copy of Meritor's warranty shall be supplied to define additional details of the warranty provisions. Vehicles that operate full or part-time outside the United States and Canada shall have a one (1) year, parts only warranty.

Page 304 of 508 ends

16.H

Page 1368 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 137 of 140 PO00022979 - 10 YEAR CAB STRUCTURAL WARRANTY
The proposed cab will be warranted against structural defects for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.

PO00022695 - 10 YEAR BODY STRUCTURAL WARRANTY
The proposed body will be warranted against structural defects for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.

PO00022698 - 10 YEAR CAB & BODY CORROSION WARRANTY
The cab and body shall be warranted against rust-through or perforation, due to corrosion from within, for a period of ten (10) years. Perforation is defined as a condition in which an actual hole occurs in a sheet metal panel due to rust or corrosion from within. Surface rust or corrosion caused by chips or scratches in the paint is not covered by this warranty.

PO00022701 - PAINT FINISH WARRANTY, TEN (10) YEAR
The proposed paint finish will be warranted for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.

PO00022702 - 5 YEAR LETTERING WARRANTY
The apparatus manufacturer will provide a five (5) year warranty against defects in material and workmanship for all graphics processes. Any valid claims must be made in writing within 15 days of the determination of any defects to the manufacturer's fire apparatus. The manufacturer will at its option make any necessary repairs either at a local authorized service center or at the factory if required. The manufacturer will make the final decision as to where the repairs are to be made and any transportation cost is the owner's responsibility. The manufacturer will at its option, repair or replace any verified defects in workmanship or materials at no cost to the owner provided all the requirements of this warranty have been met.

The manufacturer will not be liable to the original purchaser or anyone else for consequential, incidental, special or direct damages, including, but not limited to, any claims for loss of profits, downtime, loss of use or inconvenience. THE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OF IMPLIED, AND SPECIFICALLY, DISCLAIMS ANY IMPLIED WARRANTY INCLUDING THE WARRANTY OF MERCHANTABILITY.

The manufacturer continually strives to improve its products and therefore, reserves the right to make improvements or changes without incurring any obligations to make such changes or additions to equipment previously sold.

Page 305 of 508 ends

16.H

Page 1369 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 138 of 140 PO00022703 - 1 YEAR BRIGHTWORK WARRANTY
KME Fire Apparatus (KME) warrants all bright finish components used in the construction of KME Fire Apparatus against defects and workmanship provided the apparatus is used in a normal and reasonable manner. This warranty is extended only to the original user-purchaser for a period of one (1) year from the date of delivery/acceptance to the original user-purchaser, whichever occurs first.

The expressed warranty excludes corrosion or degradation of bright finished components caused by damage to the component.

PO00022981 - 10 YEAR STAINLESS-STEEL PIPING WARRANTY
The proposed stainless-steel plumbing will be warranted for a period of ten (10) years from the date of acceptance of the unit. Details of warranty coverage, limitations and exclusions are included in the specific warranty document.

PO00024719 - FRONT SUSPENSION - HENDRICKSON STEERTEK - 5 YEAR WARRANTY The Hendrickson Steertek NXT front axle shall be provided with a five (5) year parts and labor warranty and shall include the axle and kingpin assembly, the steering arm assembly, and the upper and lower steering knuckle assembly.

The warranty for the integrated suspension components shall be two (2) years or two hundred fifty thousand (250,000) miles, whichever occurs first.

The integrated suspension components covered under this two year warranty are limited to:
• Front Frame Hanger Assemblies
• Rear Shackle Assemblies
• Jounce Stop Assemblies
• Rear Frame Hanger Assemblies
• Shock Absorbers
• Shock Absorber Brackets
• Leaf Spring Assemblies
A copy of the Hendrickson Steertek NXT Warranty shall be provided to define additional details of the warranty provisions.

PO00023672 - REAR SUSPENSION - HENDRICKSON AIR RIDE - SINGLE AXLE -THREE YEAR WARRANTY Hendrickson warrants suspension products manufactured by it to be free from defects in material and workmanship which occur under normal use and service for a period of three(3) years (base year + 2 years).

This warranty will not apply and no warranty of any kind will exist as to any product which has been subject to abuse, misuse, neglect, misapplication or accident of any type or cause or which has been repaired, replaced, substituted or used with parts other than genuine Hendrickson parts or altered by anyone.

Page 306 of 508 ends

16.H

Page 1370 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 139 of 140 PO00022973 - LIFETIME POLY TANK WARRANTY - ALL TANKS
The proposed water tank will be warranted by the water tank manufacturer for the "Lifetime" of the unit. A copy of the manufacturer's warranty will be supplied to define additional details of the warranty provisions.

PO00022734 - HALE FIRE PUMP LIMITED STANDARD WARRANTY
Hale Products, Incorporated ("Hale") hereby warrants to the original buyer that products manufactured by Hale shall be free of defects in material and workmanship for a period of five (5) years from the date product is first placed into service or five and one-half (5 1/2) years from date of shipment by Hale, whichever period shall be first to expire. Within this warranty period, Hale will cover parts and labor for the first two (2) years and parts only for years three (3) through five (5).

PO00022959 - FOAM PRO 2000 SERIES- FOAM SYSTEM - STANDARD WARRANTY The liability of FoamPro under the foregoing warranty will be limited to the repair or replacement at FoamPro’s option without charge for labor or materials of any parts upon return of the entire pump, system or other product or of the particular part to the FoamPro factory within the warranty period, at the sole expense of the purchaser, which part will upon examination appear to FoamPro’s satisfaction to have been defective in material and workmanship.

PO00022989 - CLASS 1 - PRODUCT WARRANTY
Class 1 warrants that any equipment of our own manufacture (or manufactured for us pursuant to our specifications) found to have defects in material or workmanship during normal use and service, will be repaired or replaced (at our opinion) free of charge, provided that written notice of such defect is received by us within two (2) years, (three 3 years on liquid filled gauges) after initial shipment.

PO00022760 - AKRON - 5 YEAR LIMITED WARRANTY
The limited warranty set forth here against defective materials or workmanship for a period of five (5) years will be given by Akron Brass Co. with respect to Akron Brass Co. products purchased and used in the United States and Canada respectively. All Akron valves are warranted for 10 years.

PO00022988 - AKRON - 5 YEAR LIMITED WARRANTY
The limited warranty set forth here against defective materials or workmanship for a period of five (5) years will be given by Akron Brass Co. with respect to Akron Brass Co. products purchased and used in the United States and Canada respectively. All Akron valves are warranted for 10 years.

PO00022983 - CLASS 1 - ELECTRICAL PRODUCT WARRANTY - 2 YEAR Class 1 warrants that any equipment of our own manufacture (or manufactured for us pursuant to our specifications) found to have defects in material or workmanship during normal use and service, will be repaired or replaced (at our option) free of charge, provided that written notice of such defect is received by us within two years (three for liquid-filled gauges) after initial shipment.

Page 307 of 508 ends

16.H

Page 1371 of 2151 ends

City of Hemet
2023 Type 1 ‘Severe Service’ Pumper

MANUFACTURERS DETAILED SPECIFICATIONS

Quote # QUO0000007365 (Rev 0) February 17, 2022 Page 140 of 140 All equipment requiring repair or replacement under this warranty will be returned prepaid to Class 1. Such returned equipment will be examined by us and, if found to be defective as a result of materials failure or workmanship, will be repaired or replaced at no charge.

PO00022985 - BOSTROM SEATING 5 YEAR LIMITED WARRANTY
H.O. Bostrom will warrant each new seat manufactured, to be free from defects in materials and workmanship when delivered to the original purchaser for a period of five (5) years.

Labor to remove or reinstall and transportation of defective items will not be covered by, or any allowance made for the said cost under this warranty.

PO00010937 - CORROSION TREATMENT
Upon apparatus completion, underside of the apparatus, from the pump enclosure-back, shall have anti corrosion film applied to help inhibit rust and the corrosion process. The semi-firm wax film shall be applied by air spray method. The film shall be applied as a minimum to the following areas: body substructure, underside of all body compartments, running board supports and rear step supports. No film shall be applied directly to the exhaust system or wheel wells.

NOTE: The film shall remain semi-firm to promote self-sealing. The film may leave a light tinted color to those areas treated.

PO00024906 - ADDITIONAL ITEMS SHIPPED WITH VEHICLE
• 1 - Pint of touch up paint for each color
• 1 - Bag of assorted stainless-steel nuts and bolts

Page 308 of 508 ends

16.H

Page 1372 of 2151 ends

TBD
C
A
B: 10
0"W
K

ME SEVERE SER
VICE LFD 10" R
R
ALU
M
EN
GINE &
TRA
NS: C
U
M
MINS X12 50
0 HP/ALLISO
N
4 0
0 0 EVS
A
XLES: 22,0
0 0
# STEERTEK FRO
N
T/24,0
0 0
# REAR
PU
MP: H
ALE Q
M
A
X-150 150
0 GPM SIN
GLE ST
A
GE/C
BP-250
W
A
TER
T
A
N
K: 50
0 G
ALLO

NS POLY
W/ 30/10
G
ALLO
N FO
A
M
B
O
D
Y
T
YPE: 143" FLA
T
B
A
C
K 12 G
A
G
ALV
FO
A
M SYSTEM: FO
A
M PR
O 20
01

Page 309 of 508 ends

16.H

Page 1373 of 2151 ends
Page 310 of 508 ends

16.H

Page 1374 of 2151 ends

DATE:

BY:

GSO:

CUSTOMER - DEALER:

BODY STYLE:

CHASSIS MAKE & MODEL:

WHEELBASE: 207
NUMBER OF PERSONNEL: 5
FRONT GVWR: 22000
REAR GVWR: 24000
TOTAL GVWR: 46000

ITEM DESCRIPTION ITEM

DETAILS
ITEM
WEIGHT
INCHES

FORWARD OF

REAR AXLE

WEIGHT ON

FRONT AXLE

WEIGHT ON

REAR AXLE
CHASSIS WEIGHT: 21384 16009 5375
PERSONNEL (DRIVER/OFFICER): 2 500 229 553 -53
PERSONNEL (CREW REAR FACING): 0 0 0
PERSONNEL (CREW FORWARD FACING): 3 750 156 565 185
BUMPER EXTENSION: 125 289 175 -50
BUMPER STORAGE WELL: 2 250 289 349 -99
CAB EMS CABINET: 2 200 202 195 5
PUMP WEIGHT: 1900 86 789 1111
CROSSLAYS: 3 600 121 351 249
SPEEDLAYS: 0 0 0
DECK GUN: 1 80 76 29 51
FRONT SUCTION: 207 0 0
REAR SUCTION: 0 0 0
FRONT DISCHARGES: 1 75 207 75 0
REAR DISCHARGES: 1 100 0 0 100
PTO PUMP: 1 2350 86 976 1374
REAR DIRECT TANK FILL: 0 0
HOSE REEL (INCLUDES HOSE): 1 250 76 92 158
WATER TANK (LOWER): 500 4450 7 150 4300
WATER TANK (UPPER): 0 0 0 0
FOAM TANK: 40 408 38 75 333
BODY WEIGHT: 4000 -12 -232 4232
EQUIPMENT ALLOWANCE: 2000 -12 -116 2116
LOCKER COMPARTMENT: 1 250 98 118 132
REAR STEP COMPARTMENT: 150 -62 -45 195
SCBA CYLINDER COMPT.: 6 180 0 0 180
HOSEBED (GENERAL): 1250 -24 -145 1395
HOSEBED (5"): 0 0 0
HOSEBED (4"): 0 0 0
HOSEBED (3"): 0 0 0
Original Issue Date: 12/20/2011
Revision: 3
Revision Date: 05/17/2018
Department: Sales Engineering
P73-1-F5
Weight Analysis Form
12/6/2021
JJM
QUOTE 7365-0

HEMET FD CA
147" FLAT BACK 12 GA GALV
100"W KME SEVERE SERVICE LFD 10" RR ALUM
Printed on: 12/8/2021 Page 1 of 2

Page 311 of 508 ends

16.H

Page 1375 of 2151 ends

DATE:

BY:

GSO:

CUSTOMER - DEALER:

BODY STYLE:

CHASSIS MAKE & MODEL:

WHEELBASE: 207
NUMBER OF PERSONNEL: 5
FRONT GVWR: 22000
REAR GVWR: 24000
TOTAL GVWR: 46000

ITEM DESCRIPTION ITEM

DETAILS
ITEM
WEIGHT
INCHES

FORWARD OF

REAR AXLE

WEIGHT ON

FRONT AXLE

WEIGHT ON

REAR AXLE
Original Issue Date: 12/20/2011
Revision: 3
Revision Date: 05/17/2018
Department: Sales Engineering
P73-1-F5
Weight Analysis Form
12/6/2021
JJM
QUOTE 7365-0

HEMET FD CA
147" FLAT BACK 12 GA GALV
100"W KME SEVERE SERVICE LFD 10" RR ALUM
HOSEBED (2.5"): 0 0 0
HOSEBED (1.75"): 0 0 0
HARD SUCTION HOSES: 0 0
LADDERS: 130 -7 -4 134
GENERATOR: 0 0
LIGHTING: 50 137 33 17
SIDE DUMPS: 0 0
REAR DUMP: 0 0
PORTABLE WATER TANK: 0 0
Q2B: 33 289 46 -13
HOSE BED COVER: 200 -24 -23 223
REAR STEP EXTENDED: 35 -85 -14 49
LADDER RACK: 200 -7 -7 207
0 0
0 0
0 0
0 0
0 0

TOTAL FRONT AXLE REAR AXLE
SUB-TOTAL: 41900 19995 21905
2% SAFETY FACTOR (GVWR): 838 400 438
TOTAL: 42738 20395 22343
CHASSIS GVWR: 46000 22000 24000
WEIGHT DIFFERENCE: 3262 1605 1657
WEIGHT DISTRIBUTION (%): 48% 52%
Printed on: 12/8/2021 Page 2 of 2

Page 312 of 508 ends

16.H

Page 1376 of 2151 ends

DATE:

BY:

GSO:

CUSTOMER - DEALER:

BODY STYLE:

CHASSIS MAKE & MODEL:

OVERALL HEIGHT:

REAR AXLE TRACK WIDTH: 72.79 Max CG Height: 58.232
OUTER REAR TIRE TO TIRE MEASUREMENT: Calculated CG: 50.48 (Assuming 24" to ground for Rear Step)

ITEM DESCRIPTION
ITEM
WEIGHT
(Wi)
INCHES
ABOVE
GROUND (yi)
W i* yi
CHASSIS CG: 21384 41 876744
PERSONNEL CG: 1250 71 88750
BUMPER EXT: 125 31 3875
PUMP (Only use if Commercial Chass.): 0
X-lay/SPEEDLAY: 600 85 51000
FRONT SUCTION: 0
REAR SUCTION: 0
FRONT DISCHARGE: 150 31 4650
DECK GUN: 80 93 7440
HOSE REEL(with hose): 250 85 21250
GENERATOR: 0
BODY CG: 4000 66 264000
EQUIPMENT CG: 2000 56 112000
WATER TANK CG: 4450 59 262550
FOAM TANK CG: 408 59 24072
HOSE LOAD CG: 1250 82 102500
HOSE BED FLOOR CG: 176 72 12672
LADDER CG: 130 108 14040
HOSE BED COVER CG: 160 100 16000
Q2B CG: 33 31 1023
SCBA CYLINDERS CG: 180 48 8640
PTO PUMP: 2350 41 96350
CALCULATED CG: 50.48
Department: Sales Engineering
P73-1-F8
Vertical CG Analysis Form
Original Issue Date: 12/20/2011
Revision: 0
Revision Date: 12/20/2011
147 FLAT BACK 12 GA GALV
100"W KME SEVERE SERVICE LFD 10" RR ALUM
12/06/21
JJM
QUOTE 7365-0

HEMET FD CA
116
Printed on: 12/8/2021 Page 1 of 1

Page 313 of 508 ends

16.H

Page 1377 of 2151 ends

KME Fire Apparatus
72 3
-69
0 Specified Hoseload Hoseload #1 Hoseload #2 Hoseload #3 Hoseload #4 Hoseload #5 Location:

Size: 2.5 4 2.5 1.75 1.75
Amount: 150 700 900 200 200
Storage Width: 6 28 25 5 5
Storage Height: 18 18 19 20 20
Storage Length: 102 102 102 102 102
Hose Width: 5 7 5 3.25 3.25
Hose Thickness: 0.75 0.75 0.75 0.69 0.69
Practical Hoselaod: 184 734 956 214 214
Specified Hoseload Hoseload #6 Hoseload #7 Hoseload #8 Hoseload #9 Hoseload #10 Location:

Size:

Amount:

Storage Width:

Storage Height: 8
Storage Length: 92
Hose Width: 0 0 0 0 0
Hose Thickness: 0 0 0 0 0
Practical Hoseload: #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0! Split Bed Width (Uses Hoseload 6-10): Remaining Hosebed Space:

Original Issue Date: 12/20/2011
Revision: 1
Revision Date: 11/01/2013
Full Width Apparatus Hosebed Width: Remaining Hosebed Space:

QUOTE 7365-0

HEMET, CA
TBD
GSO:

Customer:

Sales Engineer:

Department: Sales Engineering
P73-1-F4
Hoseload Layout Guide
Split Bed Width (Uses Hoseload 1-5): Remaining Hosebed Space:

Created On: 12/8/2021

Page 314 of 508 ends

16.H

Page 1378 of 2151 ends

THIRD MODIFICATION OF AGREEMENT NO. 10409 (CCS)
This Third Modification of Agreement Number 10409 (CCS) ("Third Modification"), entered into as of ___________, by and between the City of Santa Monica, a municipal corporation ("City"), and Kovatch Mobile Equipment Corporation ("KME") is made with reference to the following:

RECITALS
A. On or about July 27, 2017, the City and KME entered into Agreement Number 10409 (CCS) for KME to provide four fire engine pumpers and one tractor drawn aerial (TDA) ladder truck ("Original Agreement").

B. On or about September 26, 2018, the City and KME entered into the First Modification to Agreement Number 10409 (CCS) ("First Modification) to provide additional manufacturing time for the delivery of the four fire engine pumpers and one tractor drawn aerial (TDA) ladder truck.

C. On or about November 7, 2018, the City and KME entered into the Second Modification to Agreement Number 10409 (CCS) ("Second Modification) to provide additional manufacturing time for the delivery of the four fire engine pumpers and one tractor drawn aerial (TDA) ladder truck.

D. The City and KME now desire to further modify the Original Agreement to increase the per unit cost of the apparatus to be provided to the City. The parties have agreed that the Original Agreement's compensation terms, as modified by the Second Modification, need to be further amended due to increased cost of materials, an update in the communications equipment, and to add an optional warranty. In addition, the parties desire to update the contract manufacturing time as identified in Exhibit C-3, update the apparatus build specifications as identified in Exhibit E-3 and Exhibit E-3A, and update the contact information to provide notice to KME under Section 7.2 of the Agreement as modified by the First Modification. For the purposes of this Third Modification, the First Modification, Second Modification, and the Original Agreement shall be referred to collectively hereafter as the "Agreement"

TERMS AND CONDITIONS
Now, therefore, the undersigned parties do hereby mutually agree to modify the Agreement as follows:

1. A new Section 5.1 entitled "Additional Compensation" shall be added to the Agreement and shall read as follows:

5.1 Additional Compensation. The City shall also compensate KME for additional services performed under this Agreement which shall include KME providing the City with two new fire

Page 1 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 315 of 508 ends

16.H

Page 1379 of 2151 ends

engine pumpers as identified in Exhibit E-3 and additional warranty as identified in Exhibit E-3A. KME’ s compensation for these additional services shall be in an amount not to exceed One Million, Six Hundred Eighty-Five Thousand, Five Hundred Ninety-Four Dollars, and Zero Cents ($1,685,594.00) and as set forth in Exhibit B-3.

2. Exhibit B-2 of the Agreement entitled "Budget" shall be deleted in its entirety and replaced with Exhibit B-3, of copy of which is attached to this Third Modification.

3. Exhibit C-2 of the Agreement entitled "Schedule Requirements" shall be deleted in its entirety and replaced with Exhibit C-3, a copy of which is attached to this Third Modification.

4. New Exhibits E-3 ("Specification Requirements") and E-3A (“Warranty Information) shall be incorporated into the Agreement. Copies of Exhibits E-3 and E-3A are attached to this Third Modification. Exhibit E-3 includes the new design specifications for the two fire engines pumpers identified in Exhibit E-3, and Exhibit E-3A provides the corresponding warranty information for the two engines.

5. Section 7.2 of the Agreement entitled "Notices" shall be deleted in its entirety and replaced with the following paragraph:

7.2 All notices, demands, requests or approvals to KME:

KME
One Industrial Complex
Nesquehoning, PA 18240 USA
Attention: Brandon Gomez
Re: Contract No, 10409

6. Except as expressly modified by this Third Modification, all other terms and conditions of the Agreement shall be and remain in full force and effect.

Page 2 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 316 of 508 ends

16.H

Page 1380 of 2151 ends

IN WITNESS WHEREOF, the parties have executed this Third Modification as of the date and year first written above.

ATTEST:
______________________________

DENISE ANDERSON-WARREN
City Clerk
APPROVED AS TO FORM:
______________________________

LANE DILG
City Attorney

CITY OF SANTA MONICA,
a municipal corporation
By: ______________________________

RICK COLE
City Manager
ABC Corporation
#VENDOR
By: _______________________________

Page 3 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03 Interim City Attorney
10/26/2021
Joseph Lawrence
10/26/2021
Anrew Baney
KME
Vice President/General Manager

Page 317 of 508 ends

16.H

Page 1381 of 2151 ends

Exhibit B-3
Budget
The City shall compensate KME for additional services set forth in Section 5.1 of the Agreement which include which shall include KME providing the City with two new fire engine pumpers as set forth in Exhibit E-3, two sets of fire communication wireless intercom systems, and two five (5) Year Comprehensive Warranties (Exhibit E-3A).

KME’ s compensation for these additional services shall be in an amount not to exceed One Million, Six Hundred Eighty-Five Thousand, Five Hundred Ninety-Four Dollars and Zero Cents ($1,685,594.00).

If the City desires to purchase additional apparatus and equipment from KME, the parties may further modify this agreement to reflect the City's desire, and such transaction shall be based on the pricing reflected in the price schedule identified in KME’ s original bid to the City dated 9/13/16. However, the total compensation paid under this Agreement, irrespective of whether the City makes an additional purchase from KME, shall at no time exceed Six Million, Three Hundred Sixty-Six, Five Hundred Thirteen Dollars and Zero Cents ($6,366,513.00).

Description Original Unit Price Revised Unit Price
Two (2) Type 1 Fire Engine Pumpers $654,239 $700,427
Equipment mounting and custom
bracket manufacturing costs
Included in price above $12,000
Delivery Included in price above $4,000
Additional Costs: Communications
package installation
Included in price above $22,056
Change Orders: 2, 6, 7, 8, 14, 15 $9,732 Included in price above 2021 Updates to Specifications Included in price above
Subtotal $663,971 $738,483
Tax $68,057 $73,024
Total with 10.25% Tax $732,028 $811,507
Approved Options Unit Price
5 Year Comprehensive Warranty
(Exhibit 3-A)
$25,790
Fire Communication Wireless Intercom $5,500
Total Unit Price $842,797
Total Price Contract
Mod 3
$1,685,594

Page 4 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 318 of 508 ends

16.H

Page 1382 of 2151 ends

Exhibit C-3
Schedule Requirements
KME shall manufacture two (2) Type I engine pumpers together with consecutive build numbers allowing for one (1) potential pre-construction inspection trip, one (l) potential in-process inspection trip, and one (1) potential final inspection trip.

Build time is defined as the time from contract written notice to proceed to engine delivery to Santa Monica, California with an approved SMFD in-service date. Build time shall simultaneously include two engine pumpers and shall not exceed 420 days.

If an additional engine pumper is ordered, the completion time shall be negotiated at the time of order.

Page 5 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 319 of 508 ends

16.H

Page 1383 of 2151 ends

EXHIBIT E-3

SPECIFICATION REQUIREMENTS

KME FIRE APPARATUS

SANTA MONICA FIRE
OCTOBER 2021

Page 6 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 320 of 508 ends

16.H

Page 1384 of 2151 ends

EXHIBIT E-3

DESIGN CLAUSE
QTY: 1
These specifications outline the components, installation methods, and operational characteristics KME is agreeing to provide in order to meet the purchaser’s requirements. Subject to the terms of the purchase agreement, other construction details not explicitly listed in these specifications will be determined at the discretion of the builder. In the event the purchaser desires a different construction or installation not already described in these specifications, additional charges may apply, and quoted lead time commitments will be adjusted.

DELIVERY TIMELINE FROM DATE OF PRE-CONSTRUCTION - 390 DAYS QTY: 1
KME is proposing to complete the apparatus delivery time based on the number of calendar days, starting from the date the pre-construction letter is signed and returned to KME Fire Apparatus.

OVERALL APPARATUS LENGTH - 352.5"
QTY: 1
OVERALL APPARATUS WIDTH - 100"
QTY: 1
OVERALL APPARATUS HEIGHT - 122"
QTY: 1
WHEELBASE - 177"
QTY: 1
MINIMUM FRONT G.A.W.R. - 20,000 LBS
QTY: 1
MINIMUM REAR G.A.W.R. - 24,000 LBS
QTY: 1
MINIMUM TOTAL G.A.W.R. - 44,000 LBS
QTY: 1

COMPLETION INFORMATION
QTY: 1
The contractor shall supply, at the time of delivery, at least one (1) copy of the following documents.

• Owners name and address Apparatus manufacturer, model and serial number • Chassis make, model and serial number
• Front tire size and total rated capacity in pounds
• Rear tire size and total rated capacity in pounds

Page 7 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 321 of 508 ends

16.H

Page 1385 of 2151 ends

EXHIBIT E-3
• Chassis weight distribution in pounds with water and manufacturer mounted equipment, front and rear
• Engine make, model, serial number, rated horsepower, rated speed and governed speed • Type of fuels and fuel tank capacity
• Electrical system voltage and alternator output in amps. • Battery make, model and total capacity in cold crank amps (CCA) • Transmission make, model, and serial number. If so equipped chassis transmission PTO(s) make, model and gear ratio
• Pump make, model, rated capacity in gallons per minute (liters per minute where applicable) and serial number
• Pump transmission make, model, serial number and gear ratio • Auxiliary pump make, model, rated capacity in gallons per minute (liters per minute where applicable) and serial number
• Water tank certified capacity in gallons or liters
• Paint manufacturer and paint number(s)
• Company name and signature of responsible company representative • Certification of slip resistance of all stepping, standing and walking surfaces.

If the apparatus has a fire pump or an industrial supply pump, the pump manufacturer's certification of suction capability.

If the apparatus has a fire pump or an industrial supply pump, a copy of the apparatus manufacturer's approval for stationary pumping applications.

If the apparatus has a fire pump or an industrial supply pump, the engine manufacturers certified brake horsepower curve for the engine furnished, showing the maximum governed speed.

If the apparatus has a fire pump or an industrial supply pump, the pump manufacturers certification of hydrostatic test.

If the apparatus has a fire pump or an industrial supply pump, the third party certification of inspection and test for the fire pump (if applicable).

If the apparatus has an aerial device the third party certification of inspection and test for the aerial device.

If the apparatus has an aerial device, all the technical information required for inspections to comply with NFPA 1911, Standards for Testing Fire Department Aerial Devices.

If the apparatus has a fixed line voltage power source, the certification of the test for the fixed power source (if applicable).

Page 8 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 322 of 508 ends

16.H

Page 1386 of 2151 ends

EXHIBIT E-3
If the apparatus is equipped with an air system, test results of the air quality, the SCBA fill station, and the air system installation.

Weight documents from certified scale - showing actual loading on the front axle, rear axle(s) and overall vehicle (with the water tank full but without personnel, equipment and hose) shall be supplied with the complete vehicle to determine compliance with NFPA-1901.

Written load analysis and results of electrical performance tests.

If the apparatus is equipped with a water tank, the certification of water tank capacity by the tank manufacturer.

FMVSS REQUIREMENT
QTY: 1
The chassis shall be certified by the apparatus manufacturer as conforming to all applicable Federal Motor Vehicle Safety Standards in effect at the date of contract.

This shall be attested to by the attachment of a FMVSS certification label on the vehicle by the contractor who shall be recognized as the responsible final manufacturer.

RECORDS
QTY: 1
KME shall be responsible for preparing and maintaining a record file of parts and assemblies used to manufacture the apparatus.

These records shall be maintained in the KME factory for a minimum of twenty (20) years.

File shall contain copies of any and all reported deficiencies, all replacement parts required to maintain the apparatus, and original purchase documents including specifications, contract, invoices, incomplete chassis certificates, quality control reports and final delivery acceptance documents.

The City of Santa Monica shall have access to any and all documents contained in this file upon official written request.

TOP OF THE LINE CHASSIS - MULTIPLEX
QTY: 1
KME shall provide a custom built chassis, which is "Top of the Line" and includes an integrated multiplexed electrical system. NO EXCEPTIONS!

GENERAL CONSTRUCTION
QTY: 1
The complete apparatus, assemblies, subassemblies, component parts, etc., shall be designed and constructed with the due consideration to the nature and distribution of the load to be sustained and to the general character of the service to which the apparatus is to be subject.

Page 9 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 323 of 508 ends

16.H

Page 1387 of 2151 ends

EXHIBIT E-3
All parts of the apparatus shall be designed with a factor of safety, which is equal to or greater than that which is considered standard and acceptable for this class of equipment in fire fighting service.

All parts of the apparatus shall be strong enough to withstand general service under full load.

The apparatus shall be so designed that the various parts and readily accessible for lubrication, inspection, adjustment and repair.

Specifications must meet minimum requirements of N.F.P.A. Pamphlet #1901 and all State and Federal Department of Transportation vehicle regulations at time of sale of unit.

The apparatus shall be designed and constructed, and the equipment so mounted, with due consideration to distribution of the load between front and rear axles that all specified equipment, including a full complement of specified ground ladders, full water tank, loose equipment, and firefighters shall be carried without overloading or injuring the apparatus.

PRODUCT LIABILITY
QTY: 1
KME shall supply proof of product liability and facility insurance equal to or exceeding $30,000,000.00.

PAINT CERTIFICATION
QTY: 1
The finish paint shall be certified by the apparatus manufacturer as conforming to all applicable Commercial Vehicle Paint Standards in effect at the date of contract.

This shall be attested to by the attachment of a Sikkens certification.

PARTS & SERVICE DEPOT
QTY: 1
The manufacturer shall have an authorized service center, with a staff of factory-trained mechanics, well versed in all aspects of service for all major components, of the apparatus within a 300-mile radius of the Purchaser.

In addition, the manufacturer shall maintain a separate service facility at the manufacturing site, in order to satisfy the need for possible major emergency service work.

PROPOSED SERVICE BY - KME FIRE APPARATUS - CA
QTY: 1

SERVICE CENTER AND PARTS DEPOT
KME Fire Apparatus

FACTORY BRANCH - CALIFORNIA

KME APPARATUS SERVICE STATEMENT

Page 10 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 324 of 508 ends

16.H

Page 1388 of 2151 ends

EXHIBIT E-3
The proposed KME Fire Apparatus vehicle is offered with complete single-source service performed by the regional KME factory service center.

Service is provided by:

KME Fire Apparatus
4725 Troy Ct.

Jurupa Valley, CA 91761
Phone: (800) 328-1033 / (909) 937-3326
Fax: (909) 937-1762
Email: [email protected]
John Whitney - Service Manager
Service Center Capabilities:

KME Fire Apparatus in Ontario, CA. celebrates fourteen (14) years of operation and employs twenty (20) people. The factory owned operation employs nine (9) full-time service mechanics two (2) certified paint and body technicians and two (2) fabrication technicians to handle any service-related issues or operational improvements that you may desire.

KME Fire Apparatus employees EVTCC and ASE certified technicians, along with PPG and DuPont certified body shop technicians.

KME Fire Apparatus operates five (5) mobile service trucks that offer In-Station Service repairs to your apparatus when needed. We also have towing available should your unit need to travel to our service facility.

KME Fire Apparatus offers a twenty-four (24) hour service plan in which assigned service personnel carry pagers; one (1) man is always on call to handle any truck that is down and out of service.

KME Fire Apparatus offers:

Sheet metal repair and fabrication
Pump and electrical repair
Aerial ladder service and repair
Booster tank repair and replacement
Minor or major refurbishment capabilities
Mobile pump testing at your facility
KME Fire Apparatus offers factory authorized service and repairs to all makes of fire apparatus equipped with Hale, Waterous and Darley Pumps.

KME Fire Apparatus has the largest inventory of apparatus parts in Southern California and offers quick turn-around parts delivery when your unit is down. We also offer a large loose goods line and apparel to service the fire industry.

KME Fire Apparatus contact information, of proud service professionals.

Page 11 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 325 of 508 ends

16.H

Page 1389 of 2151 ends

EXHIBIT E-3
Service Contacts - (951) 685-1237
John Whitney - Service Manager
Alfred Dominuez - Warranty
Parts and Loose Goods Sales - (951) 685-1237
Matthew Groth – Parts Manager
KME Fire Apparatus employees are protected by Workmens’ Compensation Insurance.

A one million dollar Garage Keepers Liability Insurance Coverage and a twenty-five million dollar Product Liability Insurance Policy protect your fire department and your fire department equipment.

SERVICE SHOP DETAILS
QTY: 1
The center must provide a full time staff of experienced technicians with all of the required equipment to provide modern, accurate and efficient service.

KME shall state the size of their shop and officer area in square feet.

They shall state the location of the facility and provide photos of both the exterior and interior of the center.

Accuracy of the description of the service center is of great importance.

PRICES & PAYMENTS
QTY: 1
The price will be F.O.B. Destination, on a delivered and accepted basis at the Fire Department.

Total price on KME's proposal sheet will include all items listed in these specifications.

KME has computed pricing less federal and state taxes. It is understood that any applicable taxes will be added to the proposed prices, unless the purchaser furnishes appropriate tax-exempt forms.

FAIR ETHICAL & LEGAL COMPETITION
QTY: 1
In order to ensure fair, ethical, and legal competition, neither original equipment manufacturer (OEM) nor parent company of the OEM shall have ever been fined or convicted of price fixing, bid rigging, or collusion in any domestic or international fire apparatus market.

There will be no exceptions.

MATERIAL & WORKMANSHIP
QTY: 1

Page 12 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 326 of 508 ends

16.H

Page 1390 of 2151 ends

EXHIBIT E-3
All equipment furnished shall be guaranteed to be new and of current manufacture, to meet all requirements of these specifications.

All workmanship shall be of high quality and accomplished in a professional manner so as to insure a functional apparatus with a pleasing, aesthetic appearance.

APPROVAL DRAWING
QTY: 1
A detailed drawing of the apparatus shall be provided to the purchaser for approval before construction begins. A copy of this drawing shall also be provided to the manufacturer's representative. Upon purchaser's approval, the finalized drawing shall become a part of the total contract.

The drawing shall show, but is not limited to, such items as the chassis make and model, major components, location of lights, sirens, all compartment locations and dimensions, special suctions, discharges, etc. The drawing shall be a visual interpretation of the apparatus as it is to be supplied.

INSPECTION TRIPS (3)
QTY: 1
KME and City of Santa Monica shall collaborate to provide three (3) factory inspection trips to the apparatus manufacturer's facility.

Lodging and vehicle transportation to/from factory and other locales in Pennsylvania shall be KME’s responsibility. The Santa Monica Fire Department will pay for air travel to/from Pennsylvania and daily meals for all members attending the inspection trips.

ACCOMMODATIONS FOR SIX (6)
QTY: 1
Accommodations shall be for six (6) Fire Department representatives per trip.

The factory visits shall occur at the following stages of production of the apparatus:

TRIP ONE (1) AT PRE CONSTRUCTION
QTY: 1
Pre-construction / blueprint review.

TRIP TWO (2) AT MID-POINT COMPLETION
QTY: 1
Midpoint completion of entire apparatus.

TRIP THREE (3) AT FINAL COMPLETION
QTY: 1
Final inspection upon completion.

Page 13 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 327 of 508 ends

16.H

Page 1391 of 2151 ends

EXHIBIT E-3
The City of Santa Monica maintains the right to inspect the apparatus, within normal business hours, at any other point during construction.

Expenses incurred during non-specified inspection visits shall be the responsibility of SMFD.

During inspection visits, the City of Santa Monica reserves the right to conduct actual performance tests to evaluate completed portions of the unit.

Testing shall be accomplished with the assistance and resources of the contractor.

At final inspection, if apparatus has an unreasonable amount of deficiences SMFD reserves the right to reschedule an additional final inspection at KME’s expense.

DELIVERY
QTY: 1
Delivery of the apparatus to the customer shall remain KME’s responsibility.

Delivery shall not occur during winter months, to prevent weather damage to new apparatus.

Depending on weather and road conditions SMFD will defer delivery without penalty.

On initial delivery of the fire apparatus, a qualified and responsible representative of the contractor shall demonstrate the apparatus and provide initial instruction to representatives of the customer regarding the operation, care, and maintenance of the apparatus and equipment supplied.

INSTRUCTION MANUALS - TWO (2) SETS - USB
QTY: 1
In accordance with standard commercial practices, applicable to each vehicle (including body and special equipment) furnished under the contract, the following listed manuals and schematics, in the quantity specified, shall be provided at time of delivery of each vehicle.

The contractor shall supply at time of delivery, two (2) USB copies of a complete operation and service manual covering the complete apparatus as delivered and accepted.

The manual shall contain the following:
• Descriptions, specifications, and ratings of chassis, pump (if applicable), and aerial device • Wiring diagrams
• Lubrication charts
• Operating instructions for the chassis, any major components such as a pump and any auxiliary systems
• Instructions regarding the frequency and procedures recommended for maintenance • Parts replacement information

PRODUCTION LEVEL ELECTRICAL DRAWINGS

Page 14 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 328 of 508 ends

16.H

Page 1392 of 2151 ends

EXHIBIT E-3
QTY: 1
KME shall provide production level harness drawings for the specific unit to be built.

PRODUCTION LEVEL ELECTRICAL DRAWINGS
QTY: 1
KME shall provide production level harness drawings for the specific unit to be built.

AS-BUILT AIR SYSTEM SCHEMATICS
QTY: 1
In accordance with standard commercial practices, KME will supply two (2) copies of "AS BUILT" air schematics/diagrams for the air system at the time of delivery.

AS-BUILT PLUMBING SCHEMATICS
QTY: 1
In accordance with standard commercial practices, the manufacturer shall supply two (2) copies of "AS BUILT" plumbing schematics/diagrams for the pumping system at the time of delivery.

VEHICLE FLUID PLATE
QTY: 1
As required by NFPA-1901, the contractor shall affix a permanent plate in the driver's compartment specifying the quantity and type of the following fluids used in the vehicle:

A permanent plate in the driving compartment shall specify the quantity and type of the following fluids used in the vehicle:

• Engine oil
• Engine coolant
• Chassis transmission fluid
• Pump transmission lubrication fluid
• Pump primer fluid
• Drive axle(s) lubrication fluid
• Air-conditioning refrigerant
• Air-conditioning lubrication oil
• Power steering fluid
• Cab tilt mechanism
• Transfer case fluid
• Equipment rack fluid
• Air compressor system lubricant
• Generator system lubricant
• Aerial systems

PRE-DELIVERY SERVICE

Page 15 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 329 of 508 ends

16.H

Page 1393 of 2151 ends

EXHIBIT E-3
QTY: 1
After transportation from the factory and immediately prior to delivery to the fire department, the apparatus shall receive a pre-delivery service consisting of: engine oil filter change, chassis lubrication, fuel filter(s) changed, adjustment of engine to manufacturers specifications, complete inspection including all electrical and mechanical devices, for proper operation and correction of leaks or obvious problems.

UNIT BUILT AT HEADQUARTERS
QTY: 1
In order to insure top quality construction, maximum assembly line and engineering communication and the highest level of manufacturing supervision the entire apparatus shall be built at the KME’s primary (headquarters) manufacturing facility.

Apparatus constructed at satellite plants will not be considered.

EXACT BLUEPRINT
QTY: 1
The drawing shall be done at the manufacturer's facility by the manufacturer's engineering department in order to guarantee the accuracy of the drawing. KME to provide SMFD Apparatus drawings- to include all modules and provide locations in schematic electronically and in paper form.

FAMA MEMBERSHIP
QTY: 1
The apparatus manufacturer must be a current member of the Fire Apparatus Manufacturer's Association (FAMA). Remove all unnecessary FAMA decals as deemed by SMFD.

MANUFACTURED IN UNITED STATES
QTY: 1
The entire apparatus shall be assembled within the borders of the Continental United States to insure more readily available parts (without added costs and delays caused by tariffs and customs) and service.

ISO REQUIREMENT
QTY: 1
The manufacturer shall operate a Quality Management System that is certified to ISO 9001 by an organization that is accredited by the ANSI-ASQ National Accreditation Board (ANAB).

This type of business management system shall allow the manufacturer to monitor processes to ensure they are effective; keep adequate records; check output for defects, with appropriate and corrective action where necessary; regularly review individual processes and the quality system itself for effectiveness; and facilitate continual improvement.

A copy of the registration certificate must be included in the proposal, NO EXCEPTIONS.

Page 16 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 330 of 508 ends

16.H

Page 1394 of 2151 ends

EXHIBIT E-3

AMP DRAW REPORT
QTY: 1
KME shall provide at the time of delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.

A written load analysis, which shall include the following:

• The rating of the alternator.
• The minimum continuous load of each component that is specified per: Applicable NFPA1901. • Additional loads that, when added to the minimum continuous load, determine the total connected load.
• Each individual intermittent load.

All of the above listed items shall be provided per the applicable NFPA-1901.

SAFETY VIDEO
QTY: 1
An apparatus safety video will be supplied with the final documentation for the apparatus.

The video will address key safety considerations for personnel to understand driving, operating, and maintenance of the apparatus.

Safety procedures like vehicle pre-trip inspection, chassis operation, pump operation, and maintenance will be covered.

COOPERATIVE PURCHASING
QTY: 1
KME shall be pleased to allow other public agencies to use the purchase agreement resulting from this invitation unless expressly noted on the proposal form that prices are not available for tag-on.

The condition of such use by other agencies shall be that any such agency must make and pursue contact, purchase order/contract, and all contractual remedies.

Such tag-ons shall be done so that the original purchasing agency has no responsibility for performance by either the manufacturer or the agency using the contract.

VEHICLE DATA PLATE DESCRIPTION
QTY: 1
The following safety signs shall be provided in the cab:

• A label displaying the maximum number of personnel the vehicle is designed to carry shall be visible to the driver.

Page 17 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 331 of 508 ends

16.H

Page 1395 of 2151 ends

EXHIBIT E-3
• “Occupants will be seated and belted when apparatus is in motion” signs shall be visible from each seat.
• “Do Not Move Apparatus When Light Is On” sign adjacent to the warning light indicating a hazard if the apparatus is moved (as described in subsequent section). • A label displaying the height, length, and GVWR of the vehicle shall be visible to driver. • This label shall indicate that the fire department will revise the dimension if vehicle height changes while vehicle is in service.

The following information shall be on labels affixed to the vehicle:

Fluid Data
• Engine Oil
• Engine Coolant
• Chassis Transmission Fluid
• Pump Transmission Lubrication Fluid
• Pump Primer Fluid (if applicable)
• Drive Axle(s) Lubrication Fluid
• Air Conditioning Refrigerant
• Air Conditioning Lubrication Oil
• Power Steering Fluid
• Cab Tilt Mechanism Fluid
• Transfer Case Fluid (if applicable)
• Equipment Rack Fluid (if applicable)
• Air Compressor System Lubricant
• Generator System Lubricant (if applicable)
• Front Tire Cold Pressure
• Rear Tire Cold Pressure
• Aerial Hydraulic Fluid (if applicable)
• Maximum Tire Speed Rating
Chassis Data
• Chassis Manufacturer
• Production Number
• Year Built
• Month Manufactured
• Vehicle Identification Number

Manufacturers weight certification:
• Gross Vehicle (or Combination) Weight Rating (GVWR or GCWR) • Gross Axle Weight Rating, Front

Page 18 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 332 of 508 ends

16.H

Page 1396 of 2151 ends

EXHIBIT E-3
• Gross Axle Weight Rating, Rear

VEHICLE TRANSPORTATION - KME PROVIDED
QTY: 1
Transportation for the completed vehicle from KME Fire Apparatus in Nesquehoning, PA to the end user shall be provided by KME.

CRITICAL OVERALL HEIGHT REQUIREMENT - "NO
QTY: 1
CRITICAL OVERALL LENGTH REQUIREMENT - "NO
QTY: 1

NFPA CERTIFICATION
QTY: 1
The proposed apparatus will be constructed to withstand the severe and continuous use encountered during emergency fire fighting services.

The apparatus will be of the latest type, carefully designed and constructed with due consideration to the nature and distribution of the load to be sustained.

This proposal details the general design criteria of cab and chassis components, aerial device (if applicable), fire pump and related components (if applicable), water tank (if applicable), fire body, electrical components, painting, and equipment.

All items of these proposal specifications will conform to the fullest extent possible with the National Fire Protection Association Pamphlet No. 1901, latest edition, except as noted in the Statement-of-Exceptions.

KME will furnish satisfactory evidence of our ability to construct, supply service parts and technical assistance for the apparatus specified.

GENERAL INFORMATION - NFPA 1901
QTY: 1
The proposed apparatus will be constructed to withstand the severe and continuous use encountered during emergency fire fighting services. The apparatus will be of the latest type, carefully designed and constructed with due consideration to the nature and distribution of the load to be sustained.

This proposal details the general design criteria of cab and chassis components, aerial device (if applicable), fire pump and related components (if applicable), water tank (if applicable), fire body, electrical components, painting, and equipment.

All items of these proposal specifications will conform to the fullest extent possible with the National Fire Protection Association Pamphlet No. 1901, latest edition, except as noted in the Statement-of-Exceptions.

Page 19 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 333 of 508 ends

16.H

Page 1397 of 2151 ends

EXHIBIT E-3

KME will furnish satisfactory evidence of our ability to construct, supply service parts and technical assistance for the apparatus specified.

NFPA TREADPLATE CERTIFICATION
QTY: 1
All stepping, standing, and walking surfaces on the body shall meet NFPA #1901 anti-slip standards.

Aluminum tread plate utilized for stepping, standing, and walking surfaces shall be Alcoa NoSlip type.

Upon request by the purchaser, the manufacturer shall supply proof of compliance with this requirement.

All vertical surfaces on the entire vehicle will also have NFPA treadplate in order to provide a consistent pattern.
"PUMPER FIRE APPARATUS" NFPA 2016 CHAPTERS
QTY: 1
The unit shall be designed to conform fully to the "Pumper Fire Apparatus" requirements as stated in the NFPA 1901 Standard (2016 Revision), which shall include the following required chapters as stated in this revision:

• Chapter 1 Administration
• Chapter 2 Referenced Publications
• Chapter 3 Definitions
• Chapter 4 General Requirements
• Chapter 5 Pumper Fire Apparatus
• Chapter 12 Chassis and Vehicle Components
• Chapter 13 Low Voltage Electrical Systems and Warning Devices • Chapter 14 Driving and Crew Areas
• Chapter 15 Body, Compartments and Equipment Mounting
• Chapter 16 Fire Pumps and Associated Equipment
• Chapter 18 Water Tanks

DIAMONDPLATE ON VERTICAL SURFACES
QTY: 1
All vertical surfaces requiring treadplate will be non-embossed, non-nfpa compliant diamondplate. This will apply to the cab step wells, rear of cab, front of body, coffin compartment sides and rear surface of body.

NFPA "CHAPTER 20" FOAM SYSTEM REQUIREMENTS
QTY: 1

Page 20 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 334 of 508 ends

16.H

Page 1398 of 2151 ends

EXHIBIT E-3
Chapter 20 Foam Proportioning Systems

SAFETY SIGNS (NFPA REQUIRED)
QTY: 1
Safety sign(s) shall be located on the vehicle at the rear step, and at any cross walkway(s), to warn personnel that riding in or on these areas while the vehicle is in motion is prohibited.

THIRD PARTY TESTING
QTY: 1
If required by the specific chapters of NFPA-1901, the proposed unit shall be tested and certified by independent third party inspectors.

All test work for fire pumps outlined in NFPA 1901, Edition shall be conducted.

The third party inspectors shall provide the manufacturer a complete written examination and test report for each inspection performed at the manufacturer's facility.

This report specifies the points of inspection and results of such examinations and tests.

The inspectors performing the test work on the units are certified to Level II in the required NDT methods, under the requirements outlined in ASNT document CP-189.

The actual person(s) performing the inspection shall present for review proof of Level II Certification in the required NDT methods.

The apparatus manufacturer shall designate, in writing, who is qualified to witness and certify these test results.

Prior to submittal to the automotive fire apparatus manufacturer, the final Report shall be reviewed by the Supervisor of Fire Equipment Services and a Registered Professional Engineer, both of whom are directly involved with the aerial device certification program.

When the unit successfully meets all the requirements outlined in NFPA 1901, current edition, the third party inspector shall issue a Certificate of Automotive Fire Apparatus Examination and Test stating the unit's compliance with NFPA- 1901.

DEALER SUPPLIED RADIO
QTY: 1

DEALER SUPPLIED COMMUNICATIONS PACKAGE
The following communications equipment will be provided by the manufacturer/SMFD and must be approved by the Santa Monica Fire Department for installation by Johnson Equipment Company of Perris California:
• Four (4) Motorola mobile radios; model APX 8500 tri-band with remote single heads • Microphones, speakers, antennas, remote head cables, and radio mic

Page 21 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 335 of 508 ends

16.H

Page 1399 of 2151 ends

EXHIBIT E-3
• Eight ( 8) Motorola portable radios; model APX 8000XE tri-band with remote microphones and portable vehicular radio chargers.
• One ( 1) ICOM IC-A 110 Aircraft radio with external speaker (check new engine for model) • 2021 Change (4) Ipads SMFD to determine size and (4)mounts. Each Ipad will need power conecition to charge ipad (1) Ipad for Officer mounted on mount center of cooling, (2) Ipads mounted in front off FF on new storage compartments. If rear facing seats are removed. • One (1) CSI intercom system with four (4) radio transmit capability. • Two (2) four-position PTI's, six (6) headset stations, four (4) radio interfaces, six (6) headsets with hangers, all power and communication cabling. (remote wireless) • KME California will facilitate scheduling and logistical support with Johnson Equipment Company after final acceptance of the apparatus from KME by the City. • SMFD will be provided equipment and installation quote prior to install for review. • The dash cutouts for the two way radios will be provided by the radio contractor. • CSI headset system has been upgraded to Firecom Wireless System as identified in Exhibit B-3
SEVERE SERVICE CAB - BASE, 96" - NON-S2020
QTY: 1
The cab shall be a custom tilt style, built specifically for fire service.

The cab shall be a cab over engine design, with integral tilt mechanism and engine access from inside the cab.

Cab shall be designed, fabricated, assembled in its entirety, and installed on the frame rails in the manufacturer's factory.

This requirement will eliminate any split responsibility in warranty and service.

The cab interior shall be the "Open-Space" design with no wall, window or vertical support posts between the front and rear crew areas to allow direct communication, better visibility and air circulation in the cab.

CAB MATERIAL
QTY: 1
The cab shall be fabricated from 5052-H 32 aluminum alloy, utilizing the minimum material thickness as follows:

• Cab side panels 0.125 thick (1/8")
• Cab roof 0.125 thick (1/8")
• Forward cab front sheet 0.125 thick (1/8")
• Interior cab panels 0.125 thick (1/8")
• Other panels 0.125 thick (1/8")
• Cab doors 0.1875 thick (3/16")
• Engine enclosure side panels 0.250 thick (1/4")

Page 22 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 336 of 508 ends

16.H

Page 1400 of 2151 ends

EXHIBIT E-3
Cab, sub-frame shall be a welded assembly, fabricated of 6063 structural aluminum alloy. This frame shall extend the full length and width of the cab and be secured to the chassis frame through two (2) rear, urethane, self centering load cushions, two (2) forward pivot brackets, and two (2) cab locks. The cab shall be of entirely welded construction.

The front cab wall shall be of double wall type construction, featuring an inner and outer panel.

No Exceptions

CRASH TESTING
QTY: 1
To ensure the safety of the cab occupants and cab integrity, proof of third party testing shall be provided.

The cab shall be certified for SAEJ2422 side impact, SAEJ2420 with ECER29 cab front impact, and ECER29 cab roof strength.

CAB LENGTH
QTY: 1
Minimum Cab Dimensions:

• Overall width 96"
• Inside width of ceiling 88"
• Front area floor to ceiling 59-3/4"
• Top of front seat to ceiling 42" (depending upon seat type) • Seat back to steering wheel 21-1/4" (depending upon seat type) • Inside width (door to engine enclosure) 25-1/4" (driver's side, at the floor) • Inside width (door to engine enclosure) 22" (officer's side, at the floor) • Crew seat area width 88"
• Front cab floor to top of engine enclosure 27”
• Front cab floor to top of center dash 34-3/4”
• Outer crew seat risers to rear wall 38-1/2"
• Centerline axle to rear wall 59-1/2"

Glass Area Dimensions:

• Windshield (Contour) 3,122 sq. in.
• Side door window, retractable 625 sq. in. each
• Side fixed crew windows 550 sq. in. each
CAB ROOF 6"
QTY: 1
Cab Entry Door Height Dimensions:

Page 23 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 337 of 508 ends

16.H

Page 1401 of 2151 ends

EXHIBIT E-3
• Forward door opening 76" high
• Rear door opening 82" high

The roof will be a split level design with radius edges for an aesthetic, streamline appearance.

The roof shall be constructed with the same material as the main structure and be internally reinforced using framing which shall span the entire width and length of the cab for maximum structural integrity. This shall allow the roof to support personnel and roof mounted equipment without the need for additional reinforcement. The cab roof over the rear crew area shall be raised six (6) inches higher than the front driver and officer area. The front face of the raised roof section shall be sloped at a 45 degree angle, creating a streamlined interface with the standard, lower, forward roof section. The forward section of the raised roof shall be notch to accommodate the roof mount air conditioning system. This design shall allow for additional interior height in the rear crew area. The rear crew area doors shall be "Vista-Style", extending full height to the radius edge of the raised roof.

Approximate dimensions:
• Crew area floor to ceiling 60"
Top of crew seat to ceiling 41" (depending upon seat type) ALUMINUM TREAD PLATE OVERLAY ON CAB ROOF 18"
QTY: 1
A bright finish aluminum tread plate overlay shall be placed on the cab roof.

The treadplate on the cab roof will extend 18" forward from the rear of cab and will be full width.

This tread plate overlay shall be sealed with caulking around the edges to prevent moisture from entering the area between the cab roof and the overlay.

CAB ROOF DRIP RAIL
QTY: 1
For enhanced protection from inclement weather, an integral drip rail shall be furnished on each side of the cab roof. The drip rail shall extend the full length of the cab roof.

CAST ANTI-SLIP ENTRY STEPS
QTY: 1
Each of the forward entrance steps shall be a minimum of 8-1/2" deep x 32" wide with the floor board recessed a minimum of 5" to avoid "shin knocking".

Each step shall be a bolt-in cast aluminum step.

The cab steps risers shall be overlaid with bright finish aluminum tread plate.

Each of the rear entrance steps shall be a minimum of 8-1/2" deep x 32" wide.

Page 24 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 338 of 508 ends

16.H

Page 1402 of 2151 ends

EXHIBIT E-3
An intermediate step shall be provided between the lower entrance step and the crew area floor for ease of entry and egress.

Each upper section of the steps and respective step risers shall be constructed as an integral part of the cab construction and shall be overlaid with bright finish aluminum tread plate.

Each lower step shall be a bolt-in cast aluminum step.

BATTERY ACCESS DOORS
QTY: 1
The battery access door(s) shall be 1/8" aluminum tread plate, drop down doors with thumb latches at each side rear cab step well.

CAB DOORS
QTY: 1
Four (4) side-opening doors shall be provided. The cab doors shall be totally constructed of aluminum with an extruded aluminum frame and an aluminum outer door skin. Doors shall be full height from the step to the cab roof extrusion and enclose the step area when the doors are closed. The forward cab door opening shall be a minimum of 37" wide and the rear cab door opening shall be a minimum of 37" wide. The rearward cab doors shall have a radius cutout allowing the door opening to protrude forward over the cab wheel well, while providing full access to the rear crew area. There shall be a heavy duty, piano type, stainless steel hinge on each door with a minimum pin diameter of 3/8". Hinges shall be slotted for ease of horizontal and vertical adjustment. There shall be a cab door seal and the doors shall close flush with the side of the cab. A heavy duty 6" wide belting material shall be utilized to prevent the cab doors from opening greater than 90 degrees.

WEATHER STRIP FASTENER
QTY: 1
Weather stripping to be mechanically fastened using a strip of aluminum that runs through the entire length of the weather strip, then screwed to the cab.

CAB DOOR INSULATION
QTY: 1
A 1/4" insulation panel shall be installed in each cab door. This insulation panel shall provide an additional acoustical barrier as well as help with heating/cooling properties of the apparatus.

CAB DOOR LATCHES
QTY: 1
Heavy-duty, bright finish cast paddle latches shall be provided on the interior and exterior of each cab door.

Door latch mechanisms which utilize spring steel clamps shall not be considered due to their tendency to both rust and break.

Page 25 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 339 of 508 ends

16.H

Page 1403 of 2151 ends

EXHIBIT E-3
The interior door latch cables/rods are to be designed to reduce adjustment or possible wear at the adjustment turnbuckles.

KEY MODEL #751
QTY: 1
The specified door lock cylinder/s shall be equipped with #751 key/s.

DOOR LOCKS
QTY: 1
Each exterior cab door shall be equipped with keyed locks. The cab doors shall be capable of being locked from the outside with a key and manually from the inside or with a momentary switch that shall either lock or unlock the doors. A switch shall be provided on both the driver and officer side of the cab dash.

DOOR LOCKS
QTY: 1
A power door lock switch will be provided for driver and officer, located as per approved dash drawing

KEYLESS ENTRY
QTY: 1
A Trimark brand, keyless entry system shall be provided on all cab doors.

This system shall lock the doors by use of the key fob and shall unlock the doors by either the key fob or the touch pads.

The system shall include two (2) "e-PAD", five number lighted touch pads mounted one (1) each side to the rear of each front cab door.

The system shall also incorporate FOUR (4) "e-FOB", 2 button RF transmitters, one (1) RF receiver module and a total of four (4) power door lock actuators.

The driver door shall have a traditional key - lock installed.

ELECTRIC WINDOWS
QTY: 1
Each side cab door shall have a tinted retractable window. The window track shall be designed into the door frame extrusion, which shall be extruded with a track groove to house a window track and seal. The window shall be capable of being removed from an access slot designed in the bottom of the door frame.

All side cab doors shall be equipped with electrically operated windows. Power window controls for all doors shall be provided on the driver's lower wing dash panel. The officer side power window control shall be on the officer's lower wing dash panel.

Page 26 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 340 of 508 ends

16.H

Page 1404 of 2151 ends

EXHIBIT E-3
The control for each rear door shall be a rocker type, automotive style switch located on the inside door panel within easy reach.

MECHANICALLY FASTEN CAB DOOR SWITCHES
QTY: 1
All cab door switches will be mechanically fastened.

DOOR WINDOW TRIM EXTRUSION
QTY: 1
Each side cab door window shall be designed with a custom extruded trim plate, which shall conform to the perimeter of the window opening in each door.

The trim plate shall extend from the edge of the door skin to the window and shall have a silver anodized finish.

CAB DOOR WINDOW SILL PROTECTION
QTY: 1
Brushed stainless steel protection caps shall be provided on each door interior window sill.

The caps shall be fabricated from 18-gauge brushed stainless steel and cover from the window edge down over the sill and meet the inner door panel top edge.

DOOR PANELS
QTY: 1
The cab door interior panels shall be covered with a brushed stainless steel panel, at full height.

The panel shall be 16 gauge stainless steel with a brushed finish and shall be designed to allow easy access to the inner door.

INNER DOOR PANEL TO BE THREE (3) PIECE DESIGN
QTY: 1
The inner door panel shall be designed as a three (3) piece panel to allow easy access to the door latching mechanism, electrical components or the window mechanism without disassembling the entire door.

ORALITE CHEVRONS INTERIOR OF CAB DOOR PANELS
QTY: 1
Four (4) Oralite chevron reflective signs shall be installed on the lowest portion of the inner door panels.

There will be one (1) on each door. These chevrons shall cover at least 962 in.

POLISHED S/S SCUFF PLATES @ EACH CAB DOOR FRAME
QTY: 1

Page 27 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 341 of 508 ends

16.H

Page 1405 of 2151 ends

EXHIBIT E-3
A polished stainless steel trim plate shall be provided rearward of each cab door opening to protect the vertical cab corner rearward of the door opening and on the cab door striker posts to protect the cab paint when exiting and entering the cab.

WINDSHIELD
QTY: 1
A two piece, symmetrical, safety glass windshield shall be provided on the cab for the driver and officer providing a clear viewing area.

The windshields shall be full width to the center of the front cab support for each side and provide the occupants with a panoramic view.

To provide enhanced peripheral vision on each side of the cab, the windshield and cab structure shall be designed with radius corners, which provide a minimum of 8" of glass area, measured from the glass face to the side edge near the door post.

The windshield shall consist of three (3) layers; the outer light, the middle safety laminate and the inner light.

The thick outer light layer shall provide superior chip resistance, the middle safety laminate layer shall prevent the windshield glass pieces from detaching in the event of breakage and the inner light shall provide yet another chip resistant layer.

The windshield will be a contour design with 3122 sq. in. of area for improved visibility and style.

The windshield glass shall be designed so it can be used on either the driver or officer side.

Single piece windshields that utilize epoxy or that are bonded to the cab structure shall not be acceptable.

WINDSHIELD WIPERS & WASHERS
QTY: 1
Dual, electric operated, pantographic type windshield wipers shall be provided.

One (1 ) electric drive motor shall be provided for each wiper. Wipers shall have "HI/LO" and "INTERMITTENT" operating speeds.

"HI/LO" speeds shall be controlled by a steering column control, within the turn signal control stem.

"INTERMITTENT" operation shall be controlled by a twist switch within the control on the steering column.

The wipers shall be of the self-parking type.

Page 28 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 342 of 508 ends

16.H

Page 1406 of 2151 ends

EXHIBIT E-3
Windshield washers shall be electric operated wet-arm type with a 3/4 gallon washer fluid reservoir, mounted behind a hinged access door in the officer side front cab step well area. The fluid level shall be visible through a cutout in the access door. This door shall be secured with two thumb latches.

The washer control shall be integral with the intermittent wiper control switch.

There shall be individual removable panels on the front face of the cab for access to the wiper motor assemblies.

Windshield wipers shall survive testing in excess of 3 million cycles in accordance with section

6.2 of SAE J198 “Windshield Wiper Systems – Trucks, Buses and Multipurpose Vehicles”.

KME shall certify that the wiper system design has been “Third party tested” and that the wiper system has met this criteria.

DELETE SIDE VIEWING WINDOWS
QTY: 1
The windows provided on each side of the cab behind the forward cab doors shall be deleted.

DARK TINT WINDOWS
QTY: 1
The windshield and the forward cab door glass shall be provided with standard DOT, green automotive tint.

If provided, the side cab windows to the rear of the front doors, the rear cab door windows, and any rear viewing windows shall be equipped with a dark, automotive tint.

CAB GRAB RAILS EXTERIOR
QTY: 1
1-1/4" diameter x 28" long, knurled bright anodized aluminum handrails shall be provided.

There will be one (1) at each cab door entrance.

Grab rail stanchions shall be chrome plated and offset when necessary to prevent "handpinching" when opening or closing the doors.

Formed rubber gaskets shall be provided between each stanchion base and the cab surface.

CAB GRAB HANDLES, INTERIOR
QTY: 1
Grab rails shall be provided to assist in entry and exiting of the cab. Each grab rail shall be a cast aluminum "D" style handle that shall have a wheelabrated finish and shall be located in the following locations:

• One (1) 11" long, horizontally mounted on each front cab door on the interior door panel

Page 29 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 343 of 508 ends

16.H

Page 1407 of 2151 ends

EXHIBIT E-3
• One (1) 11" long, horizontally mounted on each rear cab door on the interior door panel

INTERIOR C POST GRAB HANDLES-BALL-BURNISHED ADD OFFICERS SIDE GRAB HANDLE A POST.

QTY: 1
Two (2) 12" long, vertically mounted, one (1) each side of the cab interior on the “C” post in the crew area.

INTERIOR GRAB RAILS-REAR CREW DOORS-BALL-BURNISHED
QTY: 1
One (1), horizontally mounted, on each rear cab door, located at the same height as the window in the lowered position.

FRONT CAB GRILLE
QTY: 1
A square mirror finished stainless steel grille shall be installed to allow for maximum air flow to the charge air cooler and the radiator. The top of the grille will have a flat area for the manufacturers emblem.

A four (4) inch wide solid band shall extend across the middle of the grill for lettering or lighting options.

SIDE CAB GRILLES
QTY: 1
Two (2) rectangle, mirror finished stainless steel air inlets/outlets shall be provided horizontally above the wheel well opening, one on each side of the cab.

The grilles shall be equipped with a mesh screen to serve as a secondary ember separator.

The design shall permit proper ducting of air through the engine compartment and cooling system.

This system shall be such that particles larger than .039 inches (1 mm) in diameter cannot reach the air filter element.

CAB EXTERIOR REAR WALL
QTY: 1
A bright finish aluminum tread plate overlay shall be provided over the entire exterior rear cab wall.

The tread plate overlay shall be sealed with caulking around the edges to prevent moisture from getting between the cab and the overlay.

NON NFPA TREADPLATE
QTY: 1
Non-embossed diamondplate on rear of cab.

Page 30 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 344 of 508 ends

16.H

Page 1408 of 2151 ends

EXHIBIT E-3

CAB WHEEL WELL LINERS - ALUMINUM
QTY: 1
The front cab, wheel wells shall be equipped with fully removable bolt-in aluminum inner wheel well liners.

The liners shall extend full depth into the truck frame.

The completely washable wheel well liners shall be designed to protect the cab substructure, inner panels, and other miscellaneous installed components from road salts, debris, dirt accumulation and corrosion.

STAINLESS STEEL CAB FENDERETTES
QTY: 1
The cab wheel well openings shall be trimmed with replaceable, bolt-in, polished stainless steel fenderettes.

The fenderettes shall be secured to the cab with stainless steel threaded fasteners along the internal perimeter of the wheel well.

Dissimilar metal tape and black vinyl trim molding shall be used where the cab and fender meet.

FRONT MUD FLAPS
QTY: 1
Heavy duty, black rubber type mud flaps shall be provided behind the front wheels. All mud flaps will be plain black with stainless steel SMFD weights at the bottom.

The rear lower surface of each front mud flap will be equipped with a four (4) inch high, brushed 12 gauge stainless steel weight that will have the letters “SMFD” cut into the metal. Letters will be 2-1/2” in height, with a ½” stroke

CAB MIRRORS
QTY: 1
Two (2) Ramco model 6001 PCHR polished aluminum, full face, heated, remote operated, 13 inches high X 9 3/4 wide mirrors, with a bottom heated / remote convex mirror, on a standard arm length of 15 inches shall be provided and installed.

The flat glass and bottom mirror head shall be remote operated with controls on the driver's lower wing panel.

The mirror head shall be attached to a polished aluminum arm mounted on the cab radius panel.

MIRROR CONTROL
QTY: 1
In addition to the switches on the driver's lower wing panel, the mirror position and heat (if applicable) controls shall be programmed into the multiplex control screen.

Page 31 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 345 of 508 ends

16.H

Page 1409 of 2151 ends

EXHIBIT E-3
DOOR WIDTH, X-MFD, LFD & X-LFD - 96" SS
QTY: 1
Cab Entry Door Width Dimensions;

• Forward door opening 37" wide
• Rear door opening 37" wide

Cab Entry Step Dimensions:

• Forward door recessed step 30" wide by 8-1/2" deep
• Rear door recessed step 20" wide x 8-1/2" deep

INTERIOR TRIM- GRAY VINYL
QTY: 1
The cab interior shall be constructed to create an ergonomically designed interior to be user friendly and functional for the driver and officer.

The forward overhead panel shall be a fabricated module, which shall have six (6), 3" diameter, adjustable, windshield defroster/heat vents and four (4) comfort vents.

All interior upholstery panels shall be gray in color.

The upholstered cab overhead and side wall portions shall utilize vinyl upholstery with padding underneath to provide additional insulation.

INTERIOR CAB WALL GRAY VINYL
QTY: 1
The interior rear wall of the cab shall be covered with gray vinyl for durability and shall match the other upholstered areas of the cab. The kick plate at the bottom of the interior rear cab wall will be non-NFPA polished aluminum tread-plate.

CAB FLOORING
QTY: 1
The floor of the driver’s compartment and the floor of the crew area shall be lined with Baryfol vinyl composite flooring to comply with NFPA noise and heat requirements.

ACOUSTICAL INSULATION
QTY: 1
One (1) inch thick acoustical insulation shall be provided on the cab roof, rear and side walls of the cab.

This material shall be fitted between the cab structural members and secured with adhesive to provide an insulation barrier for noise and heat.

Page 32 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 346 of 508 ends

16.H

Page 1410 of 2151 ends

EXHIBIT E-3

TREAD PLATE FOOT PADS ON FLOOR
QTY: 1
An aluminum tread plate foot pad shall be provided at each seating position.

This foot pad shall be overlaid on top of the standard flooring.

ENGINE ENCLOSURE ACCESS
QTY: 1
A padded, hinged access door shall be provided in the top rearward portion of the engine enclosure. The door shall allow access to the engine oil, transmission fluid, power steering fluid level dipsticks and the windshield washer fluid reservoir. The access door shall be provided with two (2) flush mounted latches and gas shock holders. There shall be a vinyl material cover over the access door to give a cleaner look to the top of the engine enclosure and doghouse area.

HD SOUNDPROOFING/ INSULATION PACKAGE UNDER ENGINE
QTY: 1
The underside of the engine enclosure shall be overlaid with Milcut, MilShield insulation.

MilShield can withstand temperatures up to 1300°F. To ensure a clean, smooth surface, this material shall have a heavy aluminum foil covering and shall be retained by aluminum panels fastened to the cab structure as needed. Any gaps in this insulation barrier shall be sealed with 3M #425 aluminized high temperature tape.

The insulation material and aluminum covering will extend the full length of the underside of the cab including the crew seating area.

HD SOUNDPROOFING/INSULATION BETWEEN UPHOLSTERY
QTY: 1
To further reduce the noise and heat levels inside the cab, 1/4" foam upholstery material shall be installed on all interior surfaces of the engine enclosure, below the upholstery material.

ENGINE ENCLOSURE OVERLAY MATERIAL
QTY: 1
The forward portion of the engine enclosure shall be covered with vinyl material formed overlay to match the balance of the cab interior. To allow maximum "elbow room" for the driver and officer, the forward portion of the engine enclosure shall feature a contour shape. The engine enclosure shall not significantly obstruct the driver's vision in any direction. The enclosure shall be an integral part of the cab structure, which shall be constructed from material providing adequate strength to support radio, map boxes, etc. The engine enclosure shall be insulated to protect from heat and sound. The noise insulation shall keep the DBA level within the limits stated in the current NFPA series 1901 pamphlet.

BRUSHED S/S SCUFF PLATES DS
QTY: 1
A brushed stainless steel scuff plate shall be provided on the vertical surface of the driver side engine enclosure.

Page 33 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 347 of 508 ends

16.H

Page 1411 of 2151 ends

EXHIBIT E-3
The scuff plates shall extend a minimum of 6" above the floor.

BRUSHED S/S SCUFF PLATES OS
QTY: 1
A brushed stainless steel scuff plate shall be provided on the vertical surface of the officer side engine enclosure.

The scuff plates shall extend a minimum of 6" above the floor.

BRUSHED S/S SCUFF PLATES REAR
QTY: 1
A brushed stainless steel scuff plate shall be provided on the vertical surface of the rear engine enclosure.

The scuff plates shall extend a minimum of 6" above the floor.

SUN VISORS
QTY: 1
To provide maximum protection for the driver and officer, two (2) padded sun visors shall be mounted in the cab overhead on each side.

OVERHEAD PANEL
QTY: 1
An overhead console with a removable pewter panel shall be provided on the cab roof between the driver and officer to permit installation of cab stereo, intercom systems, arrow stick controls, etc.

The overhead console shall not obstruct the driver's vision through the officer's side window.

SEAT AND SEAT BELT ANCHOR TESTING
QTY: 1
Each seat belt anchor shall be tested to withstand 3,000lbs of pull on both the lap and shoulder belt in accordance with FMVSS 210 section 4.2.

Each seat mounting position shall be tested to withstand 20G's of force in accordance with FMVSS 207 section 4.2(c).

Both tests shall be performed and verified at a third party testing and evaluation center.

STORAGE COMPARTMENTS UNDER FRONT SEATS
QTY: 1
There shall be a compartment provided under each front seat.

Each compartment shall be accessible from the front of the seat riser when the door is opened.

SEAT RISER PULL OUT DRAWERS

Page 34 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 348 of 508 ends

16.H

Page 1412 of 2151 ends

EXHIBIT E-3
QTY: 1
Two (2) enclosed drawer assemblies will be provided, located one (1) each side below the forward Driver and Officer seats, between the seat "C" channel risers. The overall dimensions of the enclosure are to be 12-1/2” wide x 5” high x 18” deep with light duty slides and an air bottle door type paddle latch.

SEAT BASE COMPARTMENT LATCHES
QTY: 1
The seat base compartments will have paddle latches.

DRIVERS SEAT
QTY: 1
The driver's seat shall be a H.O. Bostrom Sierra 500 Series EX8 high, back bucket ABTS LH seat.

The seat shall have a tapered, ergonomic, contoured, extended seat cushion with bolster support.

The seat shall have an eight inch, before and after adjustment, as well as a 2 inch height adjustment, a front of seat tilt, a rear of seat tilt, and a reclining seat back.

All seat movements shall be electrically controlled from a control panel on the forward, lower, edge of the seat.

The seat shall be equipped with a red, integrated, 3-point shoulder harness with a lap belt, and an automatic Dual Retractor anti-binding webbing guide built into the seat assembly with RiteHite Seat Belt customized, fit Adjustment. Female receiver must be long enough to allow FF to buckle while in full turnout gear coat and pants. Seat manufacturer must make seat cushion low enough to allow firefighters to be buckled in full turnout gear while maintaining the NFPA seatbelt requirements.

OFFICERS SEAT
QTY: 1
The officer's seat shall be a H.O. Bostrom Sierra 500 Series, EX8, high back, bucket ABTS RH seat.

The seat shall have a tapered, ergonomic, contoured, extended seat cushion with bolster support.

Seat shall have a six inch before and after adjustment, a 2 inch height adjustment, front of seat tilt, rear of seat tilt, and a reclining seat back.

All seat movements shall be electrically controlled from a control panel on the forward, lower edge of the seat.

The seat shall be equipped with a red, integrated, 3-point shoulder harness with lap belt, and an automatic Dual Retractor with anti-binding webbing guide built into the seat assembly with RiteHite Seat Belt customized fit Adjustment. Female receiver must be long enough to allow FF

Page 35 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 349 of 508 ends

16.H

Page 1413 of 2151 ends

EXHIBIT E-3
to buckle while in full turnout gear coat and pants. Seat manufacturer must make seat cushion low enough to allow firefighters to be buckled in full turnout gear while maintaining the NFPA seatbelt requirements

OUTBOARD REAR FACING SEAT, DRIVERS SIDE
QTY: 1
The driver's side, outboard, rear facing crew seat shall be a H.O. Bostrom Tanker 550, ABTS RH series fixed base SCBA seat.

The seat shall have a tapered, ergonomic, contoured, extended seat cushion with bolster support.

The seat shall include a SCBA storage area with integral, contoured headrest and tapered side cushions with built in SCBA strap hooks.

The seat shall be equipped with a red, integrated, 3-point shoulder harness with lap belt, and an automatic Dual Retractor with anti-binding webbing guide built into the seat assembly with RiteHite Seat Belt customized fit Adjustment.

SCBA BRACKET
QTY: 1
The driver's side, rear facing, outboard seat shall include a H.O. BOSTROM Secure All SCBA Locking System. The bracket system shall be free of straps and clamps that may interfere with auxiliary equipment on SCBA units. The center guide fork shall keep the tank in-place for a safe and comfortable fit in seat cavity. Fire fighters shall simply push the SCBA unit against the pivot arm to engage the patented auto-locking system. Once the lock is engaged, the top clamp shall surround the top of the SCBA tank for a secure fit in all directions.

The standard release handle shall be integrated into the seat cushion for quick and easy release and shall eliminate the need for straps or pull cords to interfere with other SCBA equipment.

OUTBOARD REAR FACING SEAT, OFFICER SIDE
QTY: 1
The officer's side, outboard, rear facing crew seat shall be a H.O. Bostrom Tanker 550, ABTS LH series, fixed base SCBA seat.

The seat shall have a tapered, ergonomic, contoured, extended seat cushion with bolster support.

The seat shall include a SCBA storage area with integral, contoured headrest and tapered side cushions with built in SCBA strap storage hooks.

The seat shall be equipped with a red, integrated, 3-point shoulder harness with lap belt, and an automatic Dual Retractor with anti-binding webbing guide built into the seat assembly with RiteHite Seat Belt customized fit Adjustment.

SCBA BRACKET
QTY: 1

Page 36 of 179 ends

DocuSign Envelope ID: BD964444-8052-4190-BF77-6BC9B0671D03

Page 350 of 508 ends

16.H

Page 1414 of 2151 ends

EXHIBIT E-3
The officer's side rear facing outboard seat shall include a H. O. BOSTROM Secure All SCBA Locking System. The bracket system shall be free of straps and clamps that may interfere with auxiliary equipment on SCBA units. The center guide fork shall keep the tank in-place for a safe and comfortable fit in seat cavity. Fire fighters shall simply push the SCBA unit against the pivot arm to engage the patented auto-locking system. Once the lock is engaged, the top clamp shall surround the top of the SCBA tank for a secure fit in all directions.

The standard release handle shall be integrated into the seat cushion for quick and easy release and shall eliminate the need for straps or pull cords to interfere with other SCBA equipment.

FORWARD FACING SEAT, OUTBOARD, DS
QTY: 1
The driver's side outboard forward facing crew seat position shall be provided.

The inner rear wall of the cab will serve for back support.

The seating position shall be equipped with a red, 3-point shoulder harness with lap belt.

FORWARD FACING SEAT, OUTBOARD, DS
QTY: 1
The driver's side outboard, forward facing, crew seat position shall have a flip-up style seat.

FORWARD FACING SEAT, OUTBOARD, OS
QTY: 1
The officer's side outboard, forward facing, crew seat position shall be provided.

The inner rear wall of the cab will serve for back support.

The seating position shall be equipped with a red, 3-point, shoulder harness with lap belt.

FORWARD FACING SEAT, OUTBOARD, OS
QTY: 1
The officer's side outboard, forward facing, crew seat shall have a flip-up style seat.

FORWARD FACING SEATBACK CUSHIONS - REAR CAB WALL
QTY: 1
The forward facing flip-up seats will be provided with an 18" wide, 24" tall and 2” thick, padded seat back on the rear cab wall, one (1) for each seat.

The seat back cushions will be mounted to a aluminum tread plate backer plate. Back cushions will have a nine (9) degree fixed recline angle.

FORWARD FACING SEAT POSITION - NO BACK, CENTER
QTY: 1
The center forward facing, crew seat position shall be provided.

Page 37 of 179 ends
← All documents from this meeting