City Council
City of Hermosa Beach
Adjourned Meeting Agenda - Final
City Hall
1315 Valley Drive
Hermosa Beach, CA
90254
Mayor
Michael Detoy
Mayor Pro Tem
Raymond Jackson
Councilmembers
Stacey Armato
Mary Campbell
Justin Massey
Thursday, March 31, 2022 6:00 PM
ADA Study Session
Hybrid virtual/in-person meetings are held pursuant to AB361 Duly posted on Monday, March 25, 2022 at 5:00 p.m. by A.Y. 1 City Council Adjourned Meeting Agenda - March 31, 2022 Final
VIEWING OPTIONS FOR PUBLIC MEETINGS
Public meetings are broadcast live on Spectrum Channel 8 and Frontier Channel 31 in Hermosa Beach. Additional viewing options are provided as a courtesy.
ZOOM: Join the meeting link if available or participate by phone YOUTUBE CHANNEL: https://www.youtube.com/c/CityofHermosaBeach90254 CITY WEBSITE: www.hermosabeach.gov and visit the Agendas/Minutes/Videos page ***PLEASE NOTE: IF YOU EXPERIENCE TECHNICAL DIFFICULTIES WHILE VIEWING THE
MEETING ON ONE OF THESE PLATFORMS, PLEASE TRY ONE OF THE OTHER VIEWING OPTIONS***
All council meetings are open to the public. PLEASE ATTEND.
The Council receives a packet with detailed information and recommendations on nearly every agenda item. City Council agenda packets are available for your review on the City's website located at www.hermosabeach.gov. Complete agenda packets are also available for public inspection in the City Clerk's office.
During the meeting, a packet is also available in the Council Chambers foyer or you can access the packet at our website, www.hermosabch.org, on your laptop, tablet or smartphone through the wireless signal available in the City Council chambers - Network ID: CHB-Guest, Password: chbguest To comply with the Americans with Disabilities Act of 1990, Assistive Listening Devices (ALD) will be available for check out at the meeting. If you require special assistance to participate in this meeting, you must call or submit your request in writing to the Office of the City Clerk at (310) 318-0204 at least 48 hours prior to the meeting.
City of Hermosa Beach Page 2 Printed on 3/26/2024
2 City Council Adjourned Meeting Agenda - March 31, 2022 Final
6:00 P.M. – STUDY SESSION
I. CALL TO ORDER
II. PLEDGE OF ALLEGIANCE
III. ROLL CALL
IV. ANNOUNCEMENTS - UPCOMING CITY EVENTS
V. APPROVAL OF AGENDA
VI. PUBLIC PARTICIPATION: Although the City Council values your comments, the Brown Act generally prohibits the Council from taking action on any matter not listed on the posted agenda as a business item. Comments from the speaker are limited to three minutes per speaker.
Hybrid virtual/in-person meetings are held pursuant to AB361. State and local officials recommend measures to promote social distancing. Members of the public may email comments to [email protected] or submit eComments until 3:00 p.m. on the meeting date.
IN-PERSON: Council Chambers, 1315 Valley Drive, Hermosa Beach JOIN THE VIRTUAL MEETING AT:
https://us02web.zoom.us/j/89968207828?pwd=bXZmWS83dmxHWDZLbWRTK2RVaUxaUT09 OR PARTICIPATE BY PHONE:
• Toll Free: 833-548-0276
• Meeting ID: 899 6820 7828, then #
• Passcode: 472825
ATTENDEES WILL BE MUTED UNTIL THE PUBLIC PARTICIPATION PERIOD IS OPENED.
If you are joining by phone, press * 9 to raise your virtual hand and * 6 to unmute your line when asked to do so. Comments from the public are limited to 3 minutes per speaker.
VII. OPENING REMARKS: City Manager Suja Lowenthal
VIII. STUDY SESSION
AMERICANS WITH DISABILITIES ACT (ADA) STUDY SESSION
(Public Works Director Joe SanClemente)
REPORT
22-0173
a.
Recommendation: Staff recommends City Council receive and discuss:
1. The City's ongoing Americans with Disability Act (ADA) program efforts;
2. The Americans with Disabilities Act (ADA) Self-Evaluation and Transition Plan (Attachment 1); and
3. The Feasibility Study for an Accessible Trail along the Greenbelt (Attachment 3).
City of Hermosa Beach Page 3 Printed on 3/26/2024
3 City Council Adjourned Meeting Agenda - March 31, 2022 Final
IX. PUBLIC PARTICIPATION: Although the City Council values your comments, the Brown Act generally prohibits the Council from taking action on any matter not listed on the posted agenda as a business item. Comments from the speaker are limited to three minutes per speaker.
X. MUNICIPAL MATTER
CONSIDERATION OF TAKING ACTION AND GIVING DIRECTION TO
STAFF ON ITEMS FROM THE AMERICANS WITH DISABILITIES ACT (ADA) STUDY SESSION
(Public Works Director Joe SanClemente)
REPORT
22-0176
a.
XI. ADJOURNMENT
City of Hermosa Beach Page 4 Printed on 3/26/2024
4 City Council Adjourned Meeting Agenda - March 31, 2022 Final
FUTURE MEETINGS AND CITY HOLIDAYS
CITY COUNCIL MEETINGS:
April 12, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
April 21, 2022 -Thursday - Adjourned Regular Meeting:
5:00 PM - FY 2022-2023 CIP Study Session
April 26, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
May 10, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
May 24, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
June 2, 2022 -Thursday - Adjourned Regular Meeting:
5:00 PM - Budget Study Session
June 14, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
June 28, 2022 - No meeting due to lack of quorum
July 12, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
July 21, 2022 -Thursday - Adjourned Regular Meeting:
6:00 PM - Joint meeting with all Boards/Commissions
July 26, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
August 4, 2022 -Thursday - Adjourned Regular Meeting:
5:00 PM - Study Session
August 9, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
August 23, 2022 - Tuesday - No Meeting (Dark for Summer Break) September 1, 2022 -Thursday - Adjourned Regular Meeting:
5:00 PM - Study Session
September 13, 2022 - Tuesday - 5:00 PM - Closed Session, 6:00 PM - City Council Meeting
September 27, 2022 - Tuesday - 5:00 PM - Closed Session, 6:00 PM - City Council Meeting
October 11, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
October 22, 2022 -Saturday - Adjourned Regular Meeting:
8:00 AM - City Council Retreat
October 25, 2022 - Tuesday - 5:00 PM - Closed Session,
6:00 PM - City Council Meeting
November 3, 2022 -Thursday - Adjourned Regular Meeting:
5:00 PM - Closed Session, 6:00 PM - Regular Meeting
November 8, 2022 - No meeting due to lack of quorum (General Election) November 22, 2022 - No meeting due to lack of quorum (Thanksgiving week) November 29, 2022 -Tuesday - Adjourned Regular Meeting:
5:00 PM - Closed Session, 6:00 PM - Regular Meeting (Installation of new officers) City of Hermosa Beach Page 5 Printed on 3/26/2024
5 City Council Adjourned Meeting Agenda - March 31, 2022 Final
CITY COUNCIL MEETINGS - CONTINUED:
December 1, 2022 -Thursday - Adjourned Regular Meeting:
6:00 PM - Mayor Transition Ceremony & Reception
December 13, 2022 - Tuesday - 5:00 PM - Closed Session, 6:00 PM - City Council Meeting
December 27, 2022 - Tuesday - No Meeting (Dark for WInter Break) BOARDS, COMMISSIONS AND COMMITTEE MEETINGS:
April 4, 2022 - Monday - 6:00 PM - Economic Development Committee Meeting April 5, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting April 19, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting May 2, 2022 - Monday - 6:00 PM - Economic Development Committee Meeting May 3, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting May 17, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting May 18, 2022 - Wednesday - 6:00 PM - Public Works Commission Meeting June 6, 2022 - Monday - 6:00 PM - Economic Development Committee Meeting June 16, 2022 - Thursday - 7:00 PM - Parks and Recreation Advisory Commission Meeting June 21, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting July 5, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting July 19, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting July 20, 2022 - Wednesday - 6:00 PM - Public Works Commission Meeting August 2, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting August 16, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting September 6, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting September 20, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting September 21, 2022 - Wednesday - 6:00 PM - Public Works Commission Meeting October 6, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting October 18, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting November 1, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting November 15, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting November 16 - Wednesday - 6:00 PM - Public Works Commission Meeting December 6, 2022 - Tuesday - 7:00 PM - Parks and Recreation Advisory Commission Meeting December 20, 2022 - Tuesday - 6:00 PM - Planning Commission Meeting CITY OFFICES CLOSED FRIDAY-SUNDAY AND ON THE FOLLOWING DAYS:
May 30, 2022 - Monday - Memorial Day
July 4, 2022 - Monday - Independence Day
September 5, 2022 - Monday - Labor Day
November 24, 2022 - Thursday - Thanksgiving Day
December 26, 2022 - Monday - Christmas Day (observed)
January 2, 2023 - Monday - New Year's Day (observed)
City of Hermosa Beach Page 6 Printed on 3/26/2024
6 City of Hermosa Beach
Staff Report
City Hall
1315 Valley Drive
Hermosa Beach, CA 90254
Staff Report
REPORT 22-0173
Honorable Mayor and Members of the Hermosa Beach City Council Adjourned Regular Meeting of March 31, 2022
AMERICANS WITH DISABILITIES ACT (ADA) STUDY SESSION
(Public Works Director Joe SanClemente)
Recommended Action:
Staff recommends City Council receive and discuss:
1. The City’s ongoing Americans with Disability Act (ADA) program efforts;
2. The Americans with Disabilities Act (ADA) Self-Evaluation and Transition Plan (Attachment 1); and
3. The Feasibility Study for an Accessible Trail along the Greenbelt (Attachment 3).
Executive Summary:
The Americans with Disability Act (ADA) Study Session details the City’s ongoing ADA program efforts, the draft Americans with Disability Act (ADA) Self-Evaluation and Transition Plan, and the Feasibility Study for an Accessible Trail along the Greenbelt.
No formal action may be taken by the City Council at the ADA Study Session. However, the meeting is an adjourned City Council meeting; therefore, action may be taken on the draft Americans with Disability Act (ADA) Self-Evaluation and Transition Plan and direction given on the Greenbelt Feasibility Study after the Study Session portion of the meeting concludes.
Background:
ADA Self-Evaluation and Transition Plan
At its July 13, 2021 meeting, City Council directed staff to return for a study session focused on the City’s Americans with Disabilities Act (ADA) program including efforts to complete the incomplete 2015 Draft ADA Transition Plan.
ADA Inspection Plus, LLC prepared a draft ADA Transition Plan for the City in 2015 to assist with the identification of physical barriers of access to facilities and to develop barrier removal solutions to facilitate access for all individuals. The report also provided an overview of the obligation public entities have to develop a Self-Evaluation and Transition Plan and outlined the plan development City of Hermosa Beach Page 1 of 9 Printed on 5/24/2023
powered by Legistar™ 7
Staff Report
REPORT 22-0173
entities have to develop a Self-Evaluation and Transition Plan and outlined the plan development process. As part of the preparation of the 2015 Draft Transition Plan, the consultant team prepared a series of Self-Evaluation Reports for the City’s main public facilities.
The City created and involved the Access Hermosa Working Group (AHWG) to help comment on the 2015 Draft Transition Plan. Formed by the City Manager, the AHWG met approximately once per month 2015 through 2019 to discuss ADA access concerns and make suggestions to City staff. In 2019, the AHWG was given the opportunity to comment on the 2015 Draft Transition Plan and submitted feedback to City staff. For a number of reasons beyond the City’s control (including exigencies created by the COVID-19 pandemic), adoption of the proposed plan was delayed.
The City has since contracted with Access, Inc. to provide Certified Access Specialist (CASp) services, review the 2015 Draft Transition Plan, and update the plan with currently known information to serve as the City’s 2022 ADA Self-Evaluation and Transition Plan (Attachments 1 and 2).
The City Manager reconvened the AHWG to meet on February 9, 2022 to comment on the draft 2022 ADA Self-Evaluation and Transition Plan and the draft Greenbelt Accessibility Feasibility Study. Staff also presented these items to the Public Works Commission at its March 2, 2022 meeting.
Greenbelt Feasibility Study for ADA Accessibility
At its February 27, 2018 meeting, City Council was presented an item titled ADA Assessment and Proposed Decomposed Granite Path on the Greenbelt during which staff recommended further review and policy direction for ADA accessibility upon the Greenbelt. Following discussion, Council directed staff to further investigate modification options to the Greenbelt for an accessible path, consistent with the current zoning requirements, and to work with the Access Hermosa Working Group (AHWG) and the Public Works Commission. Council further directed staff to include in the agenda item presented to the Public Works Commission a report from a landscape architect with options allowed under existing zoning requirements.
The City contracted with an ADA specialist, Access, Inc., and a landscaping architect, SWA Group, to study the feasibility of an accessible trail along a portion of, or throughout, the Greenbelt (Attachment 3). The work was done as part of a Capital Improvement Project (CIP) Study 544- Greenbelt Accessible Path Assessment.
Past Commission and Council Actions
Meeting Date Description
February 27, 2018 Council directed staff to continue to work with AHWG, Public Works Commission, and the City Attorney and
return to the Council at a future meeting with
recommendations for either (1) implementing the proposed Greenbelt modifications consistent with current zoning
requirements, OR (2) providing the actions needed to
place the issue of potential mo difications to The Greenbelt City of Hermosa Beach Page 2 of 9 Printed on 5/24/2023
powered by Legistar™ 8
Staff Report
REPORT 22-0173
Past Commission and Council Actions
Meeting Date Description
February 27, 2018 Council directed staff to continue to work with AHWG, Public Works Commission, and the City Attorney and
return to the Council at a future meeting with
recommendations for either (1) implementing the proposed Greenbelt modifications consistent with current zoning
requirements, OR (2) providing the actions needed to
place the issue of potential mo difications to The Greenbelt as a ballot measure at a future election. Staff was further directed to include, in the agenda item presented to the Public Works Commission, a report from a landscape
architect with opinions on options within existing zoning requirements, making clear that the issue is to be brought back as time allows.
July 13, 2021 As part of the Adoption of the Fiscal Year 2021 –22 Budget, City Council directed staff to return for a study session focused on the City’s Americans with Disabilities Act (ADA) program including efforts to complete the
incomplete 2015 Draft ADA Transition Plan.
March 2, 2022 Public Works Commission (PWC) received and filed the draft ADA Self-Evaluation and Transition Plan and the
draft Feasibility Study for an Accessible Trail along the Greenbelt and recommended City Council approve the
draft ADA Self -Evaluation and Transition with the
incorporation of PWC comments.
Discussion:
City ADA Program Efforts
The City of Hermosa Beach has actively made and continues to make significant efforts improving accessibility throughout the City. Some of those efforts include dedicating an ADA coordinator; retaining a Certified Access Specialist (CASp) consultant; establishing an ADA grievance process; and finalizing the City’s draft ADA Self-Evaluation and Transition Plan. The City has also committed approximately $662,000 in Fiscal Year 2021-2022 to address ADA issues and grievances, fund ADA City of Hermosa Beach Page 3 of 9 Printed on 5/24/2023
powered by Legistar™ 9
Staff Report
REPORT 22-0173
consulting, and address priority accessibility enhancement needs.
The City also incorporates ADA improvement elements throughout Capital Improvement Projects (CIPs) and private developments on a continuous basis. Examples include adding new curb ramps as part of pavement resurfacing, installing and updating ADA parking spaces, ensuring ADA compliance of new city facilities, such as the park restrooms, and increasing accessibility to beaches and parks.
ADA Self-Evaluation and Transition Plan
The City brought aboard a CASp consultant, Access, Inc. to review and update the 2015 Draft ADA Transition Plan and associated facilities site surveys (Attachment 2), which once finalized and adopted by City Council, will serve as the City’s 2022 ADA Self-Evaluation and Transition Plan (“2022 Transition Plan”).
An ADA transition plan is a living document and is a tool that Title II of the ADA requires cities to develop, identifying and prioritizing accessibility issues. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible. Given the tremendous amount of time and expense needed to achieve complete program accessibility, the primary purpose of a transition plan is to demonstrate a city’s good faith commitment to doing so, which in many cases requires several decades.
Title II of the ADA requires that public entities take several steps designed to achieve program accessibility, including preparation of the self-evaluation and notice to the public. Public entities with 50 or more employees are also required to develop a grievance procedure, designate an ADA coordinator, develop a transition plan if structural changes are necessary for achieving program accessibility, and retain the self-evaluation for three years.
Five phases of access compliance were used to assess the status of the City’s Program Accessibility including Commitment, Self-Evaluation, Transition, Implementation, and Ongoing Support. The City is currently engaging in ongoing efforts in all five phases of access compliance with recommended actions, which include finalizing the draft ADA Transition Plan and the subsequent approval and adoption of the ADA Transition Plan by City Council.
The City’s 2022 Transition Plan is intended to consolidate the unfinished 2015 Draft Transition Plan prepared by ADA Inspection Plus, LLC. and the self-evaluation of selected facilities completed to date. Although areas of self-evaluation are yet to be completed, the report nonetheless functions as the City’s 2022 Transition Plan to demonstrate its good faith commitment to achieve program accessibility in measurable steps and goals over the next several decades. Areas yet to be examined City of Hermosa Beach Page 4 of 9 Printed on 5/24/2023
powered by Legistar™ 10
Staff Report
REPORT 22-0173
accessibility in measurable steps and goals over the next several decades. Areas yet to be examined for accessibility will be the subject of individualized self-evaluation reports to be completed at a later date and then added to the 2022 Transition Plan at that time.
The 2022 Transition Plan identifies physical barriers at City facilities, compiles ADA facility evaluation reports, provides cost estimates of improvements, identities priorities, and provides an implementation schedule of the improvements. As mentioned, the 2022 Transition Plan is a living document that requires updating as accessibility goals are achieved and new ones arise. The ADA improvements that are recommended in the 2022 Transition Plan will require funding and resource commitment from the City to implement. Implementation of these improvements will take time, some of which will span several decades.
Greenbelt Feasibility
The Feasibility Study for an Accessible Trail along the Greenbelt, prepared by the City’s consultant Access, Inc., assesses the practicality of providing an accessible route along a portion, or throughout the Greenbelt.
The Greenbelt was developed in 1986 on an abandoned Santa Fe Railroad spur. Over time, the City provided incremental access improvements to the Greenbelt with the construction of curb ramps and ramps at cross streets and various mid-block points of access. Additionally, the City also installed workout stations, water fountains, benches, and monuments.
The Greenbelt is currently zoned O-S-1 Restricted Open Space. As per Hermosa Beach Municipal Code (HBMC) § 17.32.010, the O-S-1 zone is intended to restrict the further use of certain designated open space to ensure permanent open space in and for public parks and recreation areas. The uses permitted in the O-S-1 zone are codified in Hermosa HBMC § 17.30.020 and lists 13 types of uses (e.g., public parks, playgrounds, bicycling and pedestrian walkways, etc.). Furthermore, improvements permitted in the Greenbelt are restricted to only nonbuilding public improvements relating to landscaping, beautification, erosion control, and irrigation improvements by the City which are consistent with or necessary to maintain and ensure permanent open space in and for public parks and recreation purposes. These restrictions are further described in the February 22, 2018 memorandum titled “Improvements on the Greenbelt” which is included as part of Attachment 3.
The 2014 Architect Barriers Act Guidelines for Outdoor Developed Areas and the 2010 American with Disabilities Act Standards for Accessible Designs were used as the reference standards for the feasibility of an accessible route on the Greenbelt. From those standards, field observations and analysis, the pedestrian trail route type was determined to be the best-suited trail type to define the required improvements and associated slope requirements for a possible Greenbelt accessible path.
One of the critical elements of an accessible path is the pathway material used. The material shall be City of Hermosa Beach Page 5 of 9 Printed on 5/24/2023
powered by Legistar™ 11
Staff Report
REPORT 22-0173
One of the critical elements of an accessible path is the pathway material used. The material shall be firm, stable, and slip resistant for it to be accessible. The existing wood chips do not meet these requirements. Another important criterion for the City is to maintain the natural look of the Greenbelt.
As such, the recommended material that best matches these requirements is decomposed granite (DG), which resembles a fine gravel or coarse sand, and can be obtained in different colors to best match the surroundings. If a new DG pedestrian trail were to be installed on the Greenbelt, drainage and grading would need to be improved to keep the trail dry. Enhanced maintenance, such as ensuring the DG remains stabilized and trimming overgrown branches and vegetation as necessary, would also need to be considered.
The feasibility study found that it is technically feasible for the City to make either all or a portion of the Greenbelt accessible, provided that slope requirements are met. The recommended location for an initial pilot project is between Pier Avenue and 8th Street as this segment offers all the elements offered elsewhere along the Greenbelt (monument, workout station, benches, water fountain, etc.).
The City engaged SWA Group, a landscape architect, to provide conceptual designs to assist with the visualization of what an accessible pedestrian trail could look like along a shorter portion of this segment of the Greenbelt from Pier Avenue to 11th Street to establish an initial pilot. The City could in the future add additional elements as discussed above or extend the pilot segment to 8th Street.
The visualizations include three options for an initial pilot along the segment of the Greenbelt, from Pier Avenue to 11th Street, to establish and detail considerations for edge treatments and colorization of the DG material:
· Option 1-replace the entire wood chip path in the pilot segment with DG. This option would be the lowest maintenance and create a seamless sense of access for all but would require the complete replacement of the wood chips and minor modifications to existing irrigation and landscaping;
· Option 2-combine wood chips and DG in the pilot segment area into one path with six feet of wood chips on one side and six feet of DG on the other side. This option would keep some of the existing wood chips to provide an option of either material for pedestrians but would require significant maintenance to prevent mixing of materials and may increase conflicts between passing users. It would also require a fixed header to separate the material which may be a potential tripping hazard. Minor modifications to existing irrigation and planting would still be needed; and
· Option 3-create a separate DG path in the pilot segment, just west of and parallel to the existing wood chip pathway. This option would provide a dedicated DG path, retain the existing wood chip path, and reduce the risk of conflicts between Greenbelt users traveling in opposite directions. This is the highest cost option and would require some planting and possible tree City of Hermosa Beach Page 6 of 9 Printed on 5/24/2023
powered by Legistar™ 12
Staff Report
REPORT 22-0173
directions. This is the highest cost option and would require some planting and possible tree removal (and replanting). Given the variability of the terrain in different segments of the Greenbelt, this approach may not be feasible for the entirety of the Greenbelt without significant regrading.
Each of these options would provide an accessible pedestrian trail on the Greenbelt. While wood chips create a barrier to some people with physical disabilities, the Greenbelt is “Safe Harbored” because it was built before the ADA. This means the City does not have to make modifications to elements in the Greenbelt that comply with ADA Standards, unless alterations occur, or through a barrier removal plan. The Access Feasibility Study of the Greenbelt will be incorporated in the City’s future Transition Plan.
In review of these options with the AHWG on February 9, 2022, the group generally favored Option 1 as it provided access for all in a single location versus separate paths for users of different abilities.
At its March 2, 2022 meeting, the Public Works Commission generally supported Options 1 or 3, with most favoring Option 3. Option 2 was the least favorable option during discussions with both groups and is not recommended by staff due primarily to concerns over maintenance. Should it decide to move forward with the pilot project, staff recommends City Council consider Option 1 as it reduces overall maintenance needs for this segment of the Greenbelt (i.e., one material), minimizes impacts to adjacent plantings, has the lowest capital cost, and provides the most equal access for users of all abilities.
General Plan Consistency:
This report and associated recommendation have been evaluated for their consistency with the City’s General Plan. Relevant Policies are listed below:
Governance Element
Goal 1. A high degree of transparency and integrity in the decision-making process.
Policies:
· 1.1 Open meetings. Maintain the community’s trust by holding meetings in which decisions are being made, that are open and available for all community members to attend, participate, or view remotely.
· 1.2 Strategic planning. Regularly discuss and set priorities at the City Council and management level to prioritize work programs and staffing needs. · 1.3 Priority-based budgeting. Utilize priority-based budgeting to ensure funding allocations are consistent with the priorities set by the community and City Council. · 1.4 Consensus oriented. Strive to utilize a consensus-oriented decision-making process.
City of Hermosa Beach Page 7 of 9 Printed on 5/24/2023
powered by Legistar™ 13
Staff Report
REPORT 22-0173
Goal 2. The community is active and engaged in decision-making processes.
Policy:
· 2.4 Public Forum. Host periodic public forums on issues important to the community, facilitating these forums with the purpose of guiding City policy.
Mobility Element
Goal 3. Public rights-of-way supporting a multimodal and people-oriented transportation system that provides diversity and flexibility on how users choose to be mobile.
Policies:
· 3.1 Enhance public rights-of-way. Where right-of-way clearance allows, enhance public rights -of-way to improve connectivity for pedestrians, bicyclists, disabled persons, and public transit stops.
· 3.10 Require ADA standards. Require that all public rights-of-way be designed per Americans with Disabilities Act (ADA) standards by incorporating crosswalks, curb ramps, pedestrian signals, and other components to provide ease of access for disabled persons.
Parks + Open Space Element
Goal 1. First class, well maintained, and safe recreational facilities, parks, and open spaces.
Policies:
· 1.4 Low-maintenance design. Promote environmentally sustainable and low maintenance design principles in the renovation, addition, or maintenance of parks and recreation facilities. · 1.5 Evaluate community needs. Conduct a periodic review of community park needs and interests to inform maintenance and investment priorities.
Goal 4. Direct and accessible routes and connections to parks, recreational facilities, and open space are provided.
Policy:
· 4.4 ADA accessible park access. Install ADA and universally accessible amenities and equipment so that all parks, beach, and trail networks are accessible to all persons.
Infrastructure Element
Goal 1. Infrastructure systems are functional, safe, and well maintained.
Policies:
· 1.1 Infrastructure systems plan. Establish and adopt an integrated, holistic systems approach to guide infrastructure development, improvement, maintenance, and resilience. · 1.2 Priority investments. Use City Council established priorities and the Capital Improvement City of Hermosa Beach Page 8 of 9 Printed on 5/24/2023
powered by Legistar™ 14
Staff Report
REPORT 22-0173
Program (CIP) to identify and allocate funding for projects identified in the infrastructure plan.
Fiscal Impact:
Funds would need to be appropriated to advance recommendations in the 2022 Transition Plan, as funds are available in future budget cycles. Staff will present the selected option for the pilot accessible trail on the Greenbelt along with other new funding requests, during the FY2022-23 budget review and approval process.
Attachments:
1. Draft 2022 ADA Self-Evaluation and Transition Plan
2. Draft ADA Self-Evaluation and Transition Plan Appendix B-ADA Evaluation Reports
3. Feasibility Study for an Accessible Trail along the Greenbelt
4. Link to February 27, 2018 City Council Staff Report on ADA Assessment and Proposed Decomposed Granite Path On Greenbelt
5. Link to July 13, 2021 City Council Staff Report for Adoption of the Fiscal Year 2021-22 Budget
6. Link to March 2, 2022 Public Works Commission Staff Report on Americans with Disabilities Act (ADA) Self-Evaluation and Transition Plan and Feasibility Study for an Accessible Trail along the Greenbelt
7. Presentation Slides
Respectfully Submitted by: Andrew Nguyen, Associate Engineer Concur: Lucho Rodriguez, Deputy City Engineer
Concur: Joe SanClemente, Public Works Director
Noted for Fiscal Impact: Viki Copeland, Finance Director Legal Review: Mike Jenkins, City Attorney
Approved: Suja Lowenthal, City Manager
City of Hermosa Beach Page 9 of 9 Printed on 5/24/2023
powered by Legistar™ 15
2901 West Coast Hwy, Suite 200, Newport Beach, CA 92663 (949) 270-2775 www.adaexperts.net City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services
DRAFT February 8, 2022
City of Hermosa Beach
Public Works Department
Administration and Engineering Division
1315 Valley Drive, Basement Level
Hermosa Beach, California 90254
Attention: Mr. Lucho Rodriguez, P.E., Deputy City Engineer Subject: Americans with Disability Act (ADA) Self Evaluation and Transition Plan City of Hermosa Beach, California 90254
Dear Mr. Rodriguez,
Access, Inc. is pleased to have the opportunity to be of service to the City of Hermosa Beach by performing a review of the City’s Draft Americans with Disabilities Act (ADA) Transition Plan. Access, Inc. reviewed a copy of the City’s 2015 Draft ADA Transition Plan and various site survey inspection reports prepared to date. The 2015 Draft ADA Transition Plan has been updated with currently known information, and together with the site surveys, serve as the City’s ADA Self-Evaluation and Transition Plan.
As will be explained in greater detail in the ADA Self-Evaluation and Transition Plan, a transition plan is a living document and is a tool the ADA requires cities to develop to identify and prioritize accessibility issues in a city’s facilities, services, and programs based on legally-mandated self-evaluations. Though the City has completed numerous self-evaluations over the years, there are some areas that are yet to be assessed for ADA compliance. This is normal. Any remaining areas will be included in future updates to the ADA Transition Plan, which we are happy to assist the City with.
If there are any questions or clarification is needed, please contact our office at (949) 270-2775.
Respectfully,
Matthew D. Steele
Certified Access Specialist (CASp) #865
16 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 2
ADA SELF-EVALUATION AND TRANSITION PLAN
City of Hermosa Beach
1315 Valley Drive
Hermosa Beach, CA 90254
17 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 3
I. INTRODUCTION
The American with Disabilities Act (ADA) enacted on July 26, 1990, is a Federal Civil Rights law prohibiting discrimination against individuals on the basis of disability. The ADA is built upon the foundation laid out by Section 504 of the 1973 Rehabilitation Act.
It uses as its model Section 504's definition of disability and then goes further. While Section 504 applies only to entities receiving federal financial assistance, the ADA covers all state and local governments, including those that receive no federal financial assistance. Section 504 works together with the ADA to protect children and adults with disabilities from exclusion, and unequal treatment in schools, jobs and the community.
While the ADA consists of five titles, Title II is the section specifically applicable to programs, services, and activities provided by “public entities” (state and local governments) including state executive agencies, towns, counties, school districts, universities, community colleges, special purpose districts, regional transit authorities, and other state and local government instrumentalities. Generally, Title II of the ADA requires a public entity to make reasonable changes to policies, ensure effective communication with people with disabilities, and provide physical access to buildings, facilities, and programs with the goal of ensuring meaningful access to all its services and offerings. This requirement extends not only to physical access to facilities, programs, and events; but also to pedestrian facilities in public rights-of-way.
To provide the legal background of this ADA Self-Evaluation and Transition Plan, Part I of this report will discuss the ADA Title II requirements applicable to public entities, including cities’ obligations to prepare self-evaluations and transition plans. Part II then goes on to summarize the City’s Transition Plan; past site-specific self-evaluations; facilities, programs, services yet to be assessed; and recommended steps to achieve access compliance, also known as “program accessibility”. It is important to stress that transition plans are living documents. Given the tremendous amount of time and expense that may be needed to achieve program accessibility, the primary purposes of a transition plan is to demonstrate a city’s good faith commitment to that goal, which in many cases requires several decades.
A. GENERAL ADA TITLE II REQUIREMENTS
1. Equality in Participation/Benefits
The ADA provides for equality of opportunity but does not guarantee equality of results.
The foundation of many of the specific requirements in the U.S. Department of Justice (the “Department”) regulations is the principle that individuals with disabilities must be provided an equally effective opportunity to participate in or benefit from a public entity's 18 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 4
aids, benefits, and services. On the other hand, as long as persons with disabilities are afforded an equally effective opportunity to participate in or benefit from a public entity's aids, benefits, and services, the ADA's guarantee of equal opportunity is not violated.
Also, the ADA generally does not require a State or local government entity to provide additional services for individuals with disabilities that are not provided for individuals without disabilities.
2. Separate Benefit/Integrated Setting
A primary goal of the ADA is the equal participation of individuals with disabilities in the "mainstream" of American society. The major principles of mainstreaming are – 1) Individuals with disabilities must be integrated to the maximum extent appropriate.
2) Separate programs are permitted where necessary to ensure equal opportunity. A separate program must be appropriate to the particular individual. 3) Individuals with disabilities cannot be excluded from the regular program or required to accept special services or benefits.
a. Separate Programs
A public entity may offer separate or special programs when necessary to provide individuals with disabilities an equal opportunity to benefit from the programs. Such programs must, however, be specifically designed to meet the needs of the individuals with disabilities for whom they are provided.
b. Relationship to “Program Accessibility” Requirement
The integrated setting requirement may conflict with the obligation to provide “program accessibility”, which may not necessarily mandate physical access to all parts of all facilities (see “Program Accessibility” section, below). Provision of services to individuals with disabilities in a different location, for example, is one method of achieving program accessibility. Public entities should make every effort to ensure that alternative methods of providing program access do not result in unnecessary segregation.
3. Reasonable Modifications
A public entity must reasonably modify its policies, practices, or procedures to avoid discrimination. If the public entity can demonstrate, however, that the modifications would fundamentally alter the nature of its service, program, or activity, it is not required to make the modification.
19 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 5
4. Maintenance of Accessible Features
Public entities must maintain in working order equipment and features of facilities that are required to provide ready access to individuals with disabilities. Isolated or temporary interruptions in access due to maintenance and repair of accessible features are not prohibited.
Where a public entity must provide an accessible route, the route must remain accessible and not blocked by obstacles such as furniture, filing cabinets, or potted plants. An isolated instance of placement of an object on an accessible route, however, would not be a violation, if the object is promptly removed. Similarly, accessible doors must be unlocked when the public entity is open for business.
Mechanical failures in equipment such as elevators or automatic doors will occur from time to time. The obligation to ensure that facilities are readily accessible to and usable by individuals with disabilities would be violated, if repairs are not made promptly or if improper or inadequate maintenance causes repeated and persistent failures.
B. EMPLOYMENT REQUIREMENTS
Beginning January 26, 1992, Title II prohibits all public entities, regardless of size of workforce, from discriminating in their employment practices against qualified individuals with disabilities.
1. Other Federal Laws Prohibiting Employment Discrimination In addition to the Title II employment coverage, Title I of the ADA and section 504 of the Rehabilitation Act of 1973 prohibit employment discrimination against qualified individuals with disabilities by certain public entities. Title I of the ADA, which is primarily enforced by the Equal Employment Opportunity Commission (EEOC), prohibits job discrimination –
1) Effective July 26, 1992, by State and local employers with 25 or more employees; and
2) Effective July 26, 1994, by State and local employers with 15 or more employees. Section 504 of the Rehabilitation Act prohibits discrimination in employment in programs or activities that receive Federal financial assistance, including federally funded State or local programs or activities. Each Federal agency that extends financial assistance is responsible for enforcement of section 504 in the programs it funds.
20 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 6
2. Reasonable Accommodation
All public entities must make "reasonable accommodation" to the known physical or mental limitations of otherwise qualified applicants or employees with disabilities, unless the public entity can show that the accommodation would impose an "undue hardship" on the operation of its program.
"Reasonable accommodation" means any change or adjustment to a job or work environment that permits a qualified applicant or employee with a disability to participate in the job application process, to perform the essential functions of a job, or to enjoy benefits and privileges of employment equal to those enjoyed by employees without disabilities. Examples include –
1) Acquiring or modifying equipment or devices;
2) Job restructuring;
3) Part-time or modified work schedules;
4) Providing readers or interpreters; and
5) Making the workplace accessible to and usable by individuals with disabilities.
However, any particular change or adjustment would not be required if, under the circumstances involved, it would result in an undue hardship. "Undue hardship" means significant difficulty or expense relative to the operation of a public entity's program. Where a particular accommodation would result in an undue hardship, the public entity must determine if another accommodation is available that would not result in an undue hardship.
C. PROGRAM ACCESSIBILITY
A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
Public entities may achieve program accessibility by a number of methods. In many situations, providing access to facilities through structural methods, such as alteration of existing facilities and acquisition or construction of additional facilities, may be the most efficient method of providing program accessibility. The public entity may, however, pursue alternatives to structural changes in order to achieve program accessibility. 21 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 7
Nonstructural methods include acquisition or redesign of equipment, assignment of aides to beneficiaries, and provision of services at alternate accessible sites. Put differently, unlike private entities under Title III of the ADA, public entities are not required to remove barriers from each facility, even if removal is readily achievable. A public entity must make its "programs" accessible. Physical changes to a building are required only when there is no other feasible way to make the program accessible.
1. Curb Ramps
Public entities that have responsibility or authority over streets, roads, or walkways must prepare a schedule for providing curb ramps where pedestrian walkways cross curbs.
Public entities must give priority to walkways serving State and local government offices and facilities, transportation, places of public accommodation, and employees, followed by walkways serving other areas. This schedule must be included as part of a transition plan (see Section F.2 “Transition Plan”, below).
2. Existing Parking Lots or Garages
A public entity should provide an adequate number of accessible parking spaces in existing parking lots or garages over which it has jurisdiction.
3. Time Periods for Achieving Program Accessibility
Public entities must achieve program accessibility by January 26, 1992. If structural changes are needed to achieve program accessibility, they must be made as expeditiously as possible, but in no event later than January 26, 1995. This three-year time period is not a grace period; all changes must be accomplished as expeditiously as possible. In addition, a public entity that employs 50 or more persons must develop a transition plan by July 26, 1992, setting forth the steps necessary to complete such changes (see Section F.2 “Transition Plan”, below).1 Title II also requires public entities to complete a self-evaluation by January 26, 1993 (see Section F.1 “Self-Evaluation”, below).2 Failure to complete a self-evaluation does not excuse public entities from compliance with Title II’s requirements.
1 Though the City has not completed a transition plan until now (which by law addresses the removal of existing structural barriers only), the City through various capital improvement programs over the decades has ensured renovations to existing public facilities and new construction comply with current California Building Code (CBC) and ADA accessibility standards. In addition, through its ADA grievance procedures, the City has made improvements to several facilities on a case‐by‐case basis. 2 While no formal self‐evaluation(s) has been prepared until recent years, the City assesses its programs, activities, and services on an ongoing basis to provide equal access to persons with disabilities (to the extent required by law) and avoid discriminatory treatment. See also fn. 1.
22 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 8
D. NEW CONSTRUCTION AND ALTERATIONS
All facilities designed, constructed, or altered by, on behalf of, or for the use of a public entity must be readily accessible and usable by individuals with disabilities, if the construction or alteration is begun after January 26, 1992. This means that the facility must be designed, constructed, or altered in strict compliance with a design standard.
The Title II regulation gives public entities a choice of two standards that may be used:
the Uniform Federal Accessibility Standards (UFAS) or the Americans with Disabilities Act Accessibility Guidelines for Buildings and Facilities (ADAAG). 28 CFR § 35.151. The major differences between these two standards as they apply to specific facilities and elements of those facilities are summarized in Section II-6.3000 of The ADA Title Technical Assistance Manual published by the U.S. Department of Justice available at https://www.ada.gov/taman2.html.
1. Curb Ramps
When streets, roads, or highways are newly built or altered, they must have ramps or sloped areas wherever there are curbs or other barriers to entry from a sidewalk or path. Likewise, when new sidewalks or paths are built or altered, there must be curb ramps or sloped areas wherever they intersect with streets, roads, or highways.
E. COMMUNICATIONS
A public entity must ensure that its communications with individuals with disabilities are as effective as communications with others. This obligation, however, does not require a public entity to take any action that it can demonstrate would result in a fundamental alteration in the nature of its services, programs, or activities, or in undue financial and administrative burdens.
In order to provide equal access, a public accommodation is required to make available appropriate auxiliary aids and services where necessary to ensure effective communication.
Examples of auxiliary aids and services for individuals who are deaf or hard of hearing include qualified interpreters, note takers, computer-aided transcription services, written materials, telephone handset amplifiers, assistive listening systems, telephones compatible with hearing aids, closed caption decoders, open and closed captioning, telecommunications devices for deaf persons (TDD's), videotext displays, and exchange of written notes.
23 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 9
Examples for individuals with vision impairments include qualified readers, taped texts, audio recordings, Brailed materials, large print materials, and assistance in locating items.
Examples for individuals with speech impairments include TDD's, computer terminals, speech synthesizers, and communication boards.
The type of auxiliary aid or service necessary to ensure effective communication will vary in accordance with the length and complexity of the communication involved F. ADMINISTRATIVE REQUIREMENTS
Title II requires that public entities take several steps designed to achieve program accessibility. These include –
The preparation of a self-evaluation; and
Notice to the public of Title II.
In addition, public entities with 50 or more employees are required to – Develop a grievance procedure;
Designate an individual to oversee Title II compliance (e.g., an ADA coordinator);
Develop a transition plan if structural changes are necessary for achieving program accessibility; and
Retain the self-evaluation for three years.
1. Self-Evaluation
All public entities subject to Title II of the ADA were required to complete a selfevaluation by January 26, 1993.3 28 Code of Federal Regulations (“CFR)” § 35.105. A self-evaluation is a public entity's assessment of its current policies and practices. The self-evaluation identifies and corrects those policies and practices that are inconsistent with the Title II requirements.
A public entity that employs 50 or more employees must retain its self-evaluation for three years. Other public entities are not required to retain their self-evaluations but are encouraged to do so because these documents are evidence a public entity's good faith efforts to comply with the Title II requirements.
3 See fn. 2, above.
24 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 10
As part of the self-evaluation, a public entity should:
1) Identify all of the public entity's programs, activities, and services; and 2) Review all the policies and practices that govern the administration of the public entity's programs, activities, and services.
Normally, a public entity's policies and practices are reflected in its laws, ordinances, regulations, administrative manuals or guides, policy directives, and memoranda. Other practices, however, may not be recorded and may be based on local custom.
Once a public entity has identified its policies and practices, it should analyze whether these policies and practices adversely affect the full participation of individuals with disabilities in its programs, activities, and services. In this regard, a public entity should be mindful that although its policies and practices may appear harmless, they may result in denying individuals with disabilities the full participation of its programs, activities, or services. A public entity should carefully examine the programs, activities, and services discussed in Section B (“Employment”), Section C (“Program Accessibility”), Section E (“Communications”), above, and more specifically perform the following in preparing a self-evaluation.
1) A public entity must examine each program to determine whether any physical barriers to access exist. It should identify steps that need to be taken to enable these programs to be made accessible when viewed in their entirety. If structural changes are necessary, they should be included in the transition plan. 2) A public entity must review its policies and practices to determine whether any exclude or limit the participation of individuals with disabilities in its programs, activities, or services. Such policies or practices must be modified, unless they are necessary for the operation or provision of the program, service, or activity.
The self-evaluation should identify policy modifications to be implemented and include complete justifications for any exclusionary or limiting policies or practices that will not be modified.
3) A public entity should review its policies to ensure that it communicates with applicants, participants, and members of the public with disabilities in a manner that is as effective as its communications with others. If a public entity communicates with applicants and beneficiaries by telephone, it should ensure that TDD's or equally effective telecommunication systems are used to 25 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 11
communicate with individuals with impaired hearing or speech. Finally, if a public entity provides telephone emergency services, it should review its policies to ensure direct access to individuals who use TDD's and computer modems. 4) A public entity should review its policies to ensure that they include provisions for readers for individuals with visual impairments; interpreters or other alternative communication measures, as appropriate, for individuals with hearing impairments; and amanuenses for individuals with manual impairments. A method for securing these services should be developed, including guidance on when and where these services will be provided. Where equipment is used as part of a public entity's program, activity, or service, an assessment should be made to ensure that the equipment is usable by individuals with disabilities, particularly individuals with hearing, visual, and manual impairments. In addition, a public entity should have policies that ensure that its equipment is maintained in operable working order.
5) A review should be made of the procedures to evacuate individuals with disabilities during an emergency. This may require the installation of visual and audible warning signals and special procedures for assisting individuals with disabilities from a facility during an emergency.
6) A review should be conducted of a public entity's written and audio-visual materials to ensure that individuals with disabilities are not portrayed in an offensive or demeaning manner.
7) If a public entity operates historic preservation programs, it should review its policies to ensure that it gives priority to methods that provide physical access to individuals with disabilities.
8) A public entity should review its policies to ensure that its decisions concerning a fundamental alteration in the nature of a program, activity, or service, or a decision that an undue financial and administrative burden will be imposed by Title II, are made properly and expeditiously.
9) A public entity should review its policies and procedures to ensure that individuals with mobility impairments are provided access to public meetings. 10) A public entity should review its employment practices to ensure that they comply with other applicable nondiscrimination requirements, including section 26 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 12
504 of the Rehabilitation Act and the ADA regulation issued by the Equal Employment Opportunity Commission.
11) A public entity should review its building and construction policies to ensure that the construction of each new facility or part of a facility, or the alteration of existing facilities after January 26, 1992, conforms to the standards designated under the applicable Title II regulation.
12) A review should be made to ascertain whether measures have been taken to ensure that employees of a public entity are familiar with the policies and practices for the full participation of individuals with disabilities. If appropriate, training should be provided to employees.
13) If a public entity limits or denies participation in its programs, activities, or services based on drug usage, it should make sure that such policies do not discriminate against former drug users, as opposed to individuals who are currently engaged in illegal use of drugs.
2. Notice to the Public
A public entity must provide information on Title II's requirements to applicants, participants, beneficiaries, and other interested persons. The notice shall explain Title II's applicability to the public entity's services, programs, or activities. A public entity shall provide such information as the head of the public entity determines to be necessary to apprise individuals of Title II's prohibitions against discrimination.
Public notice methods include the publication of information in handbooks, manuals, and pamphlets that are distributed to the public to describe a public entity's programs and activities; the display of informative posters in service centers and other public places; or the broadcast of information by television, radio, or the internet. In providing the notice, a public entity must comply with the Title II requirements for effective communication, including alternate formats, as appropriate.
3. Development of Grievance Procedures
A public entity that employs 50 or more persons must adopt and publish grievance procedures providing for the prompt and equitable resolution of complaints alleging any action that would be prohibited by Title II.
4. Designation of Responsible Employee
27 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 13
In addition, a public entity that employs 50 or more persons shall designate at least one employee to coordinate its efforts to comply with and fulfill its responsibilities under Title II, including the investigation of complaints. A public entity shall make available the name, office address, and telephone number of any designated employee. This person is commonly referred to as the ADA Coordinator.
5. Transition Plan
Where structural modifications are required to achieve program accessibility, a public entity with 50 or more employees must develop a transition plan by July 26, 1992, that provides for the removal of these barriers. 28 CFR § 35.150(d).4 Any structural modifications must be completed as expeditiously as possible, but, in any event, by January 26, 1995. When completed, a copy of the transition plan must be made available for public inspection.
A transition plan must contain at a minimum –
1) A list of the physical barriers in a public entity's facilities that limit the accessibility of its programs, activities, or services to individuals with disabilities; 2) A description of the methods to be utilized to remove these barriers and make the facilities accessible;
3) The schedule for taking the necessary steps to achieve compliance with Title II’s regulations. If the time period for achieving compliance is longer than one year, the plan should identify the interim steps that will be taken during each year of the transition period; and
4) The name and contact information of the public official responsible for the plan’s implementation.
4 See fn. 1, above.
28 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 14
II. 2022 ADA SELF-EVALUATION AND TRANSITION PLAN
A. PREFACE
This report is intended to consolidate the unfinished 2015 Draft Transition Plan by ADA Inspection Plus, LLC. and the self-evaluation of selected facilities to date. Though areas of self-evaluation are yet to be completed, this report nonetheless functions as the City’s 2022 Self-Evaluation and ADA Transition Plan (“2022 Transition Plan”) to demonstrate its good faith commitment to achieve program accessibility in measurable steps and goals. Areas yet to be examined for accessibility will be the subject of individualized self-evaluation reports to be completed at a later date.
B. FOCUS OF 2022 TRANSITION PLAN
This report focuses on subtitle A of Title II. Subtitle A is intended to protect qualified individuals with disabilities from discrimination on the basis of disability in the services, programs, or activities of all State and local governments. It additionally extends the prohibition of discrimination on the basis of disability established by section 504 of the Rehabilitation Act of 1973, as amended, to all activities of State and local governments, including those that do not receive Federal financial assistance.
Barriers that deny or limit access to programs, services or activities may be structural or nonstructural. This report focuses on structural barriers. Structural barriers are referenced in this 2022 Transition Plan by site and are described in detail in the selfevaluation reports of sites inspected over the years. It is important to note that the recommended corrections in site evaluation reports are options, and that some structural barriers may be addressed by using a programmatic methodology if they do not involve new construction or new remodeling and renovation.
C. CURRENT STATUS OF ACCESS COMPLIANCE
This report applies a simplified conceptual framework known as the “Five Phases of Access Compliance” to assess the status of the City’s program accessibility. This framework was created by the State of California Department of Government Services (DGS), the five phases of which are summarized below.5
5 The DGS framework is derived from Title II and California Government Code Section 4450 et seq. and do not have the force of law. The Five Phases framework was developed as an advisory bulletin for public entities that, like the City, are subject to both Title II of the ADA and Title 1, Division 5, Chapter 7 (Access to Public Buildings by Physically Handicapped Persons) of the California Government Code, commencing with Section 4450. Chapter 7 requires that buildings, structures, sidewalks, curbs, and related facilities funded by state, county, or municipal funds be 29 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 15
Phase I. Commitment
This phase involves the designation of an employee as the ADA Coordinator, notice to the public of how Title II applies to the public entity, adoption of an ADA Grievance procedure, and the hiring of a Certified Access Specialist (CASp).
Phase II. Self-Evaluation
This phase involves the completion of a self-evaluation as described in Section F.1 (“Self-Evaluation”), above.
Phase III. Transition
This transition phase involves the development and completion of a transition plan as described in Section F.2 (“Transition Plan”), above.
Phase IV. Implementation
This phase achieves the goals established in the self-evaluation and transition plan.
Phase V. Ongoing Support
This phase is the maintenance and quality control phase and includes such steps as a final report on compliance status, periodic evaluations of compliance status, scheduled maintenance of access features, resolution of access issues as they arise, and ensuring new facilities, alterations, and repairs are ADA-compliant.
Table 1 below sets forth a basic summary of the current status of the City’s program accessibility.
accessible to and usable by persons with disabilities. Such publicly funded facilities (which include those leased by a city) must comply with the California Building Code (CBC) Standards relating to access to persons with disabilities and federal standards.
30 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 16
TABLE 1
FIVE PHASES OF ACCESS COMPLIANCE
Phase Status Steps Taken Actions
Required/Recommended
I: Commitment Ongoing ADA Coordinator has been
designated, grievance
procedures developed, and
CASp consultant hired.
Provide public notice of ADA
requirements applicable to City,
and maintain commitment to
access compliance.
II: Self
Evaluation
Ongoing ADA inspection reports are
completed for (1) main public
buildings; (2) main parking
lots and on-street parking
segments; and (3) sidewalks
and curb ramps.
1) Update existing ADA reports;
(2) complete self-evaluation of
remaining programs, services,
and facilities; (3) and review
every 3-4 years.
III: Transition Ongoing 2022 Transition Plan has
been prepared.
Incorporate updated ADA
reports, self-evaluation of
remaining programs, services,
and facilities into Plan, and
review Plan every 3-4 years.
IV:
Implementation
Ongoing Not yet applicable; City will
complete goals in 2022
Transition Plan according to
recommendations and
implementation schedule
shown in Appendix A.
Update the implementation
dates in the ADA reports and
Transition Plan as budget and
priority dictates.
V. Ongoing
Support
Ongoing City is employing its
grievance procedure,
ensures public works
projects meet CBC and ADA
regulations, and is in regular
contact with its CASp
employee or consultant.
Provide periodic assessment
related to the proper
maintenance of all access
features.
D. 2022 ADA TRANSITION PLAN DOCUMENTS
Access, Inc. has reviewed the documents listed below. Each evaluation report contains an inventory of features at a facility (e.g., parking signs and striping) and an assessment of these features’ compliance with applicable CBC and ADA standards. The earliest evaluation report was prepared in 2015, and as discussed in the “Recommendations” 31 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 17
section below, these reports should be updated by the time of the City’s next transition plan cycle to reflect current conditions (e.g., compliance achieved, structure removed, etc.). Access, Inc. has updated cost estimates in the summary assessment included with the 2015 Draft Transition Plan, and added cost estimates and the status of completed work to the City of Hermosa Beach Citywide Disabled Parking Report prepared by Creative Design Associates & Martin Brothers Construction Services. The updated costs to correct each violation listed in the 2015 Draft Transition Plan were based on an average inflation rate of 2.21% per year. The estimated costs do not include design, project and/or construction management, construction inspection and any contingencies.
These updates are indicated in bold red text in the reports. Hermosa Beach Draft Transition Plan, dated September 24, 2015 (ADA Inspection Plus LLC)
Program Accessibility Evaluation Reports (ADA Inspection Plus LLC) for:
o 13th St. Parking Structure
o Clark Building
o Valley Park Building
o Kiwanis Shared Building Exterior Access & Parking
o Hermosa Beach Kiwanis Club
o Hermosa Beach Rotary Club
o Fire Department
o Police Department
o City Hall
o Civic Center Exterior
o City Yard
o Base 3 Building
o South Park Building
o Community Center & Theatre
City of Hermosa Beach Citywide Disabled Parking Report, dated June 13, 2017 (Creative Design Associates & Martin Brothers Construction Services) Hermosa Beach On-Street Disabled Parking Report, dated June 13, 2017 (Creative Design Associates & Martin Brothers Construction Services) Citywide Building and Facilities Condition Assessment CIP 13-664 ADA Sidewalks and Curb Ramps Evaluation, dated May 2015 (CivilSource, Inc.)
1. 2015 City of Hermosa Beach Draft Transition Plan
The City of Hermosa Beach Title II Comprehensive Evaluation and Transition Plan, Revision 1, dated September 24, 2015 (the “2015 Draft Transition Plan”), was prepared by ADA Inspection Plus, LLC. (See Attachment A of Appendix B.) The report was prepared to assist the City with identifying physical barriers of accessibility and to develop barrier removal solutions that will facilitate the opportunity of access to all 32 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 18
individuals. The 2015 Draft Transition Plan describes the process by which facilities were evaluated for compliance with the ADA; presents the findings of that evaluation; and provides recommendations to ensure compliance. Like this 2022 ADA Transition Plan, the report also provides an overview of the obligation public entities have to develop a Self-Evaluation and Transition Plan and outlines the plan development process. Additionally, the report describes the differences between policies and programs and establishes the relationship between physical and programmatic barriers to accessibility.
2. 2015 Draft Transition Plan Evaluation Reports – Main Public Facilities To prepare the 2015 Draft Transition Plan, ADA Inspection Plus, LLC also prepared Program Accessibility Evaluation Reports for the City’s main public facilities. They are attached to this report as indicated in the chart below.
Facility Address
Report
Date Attachment
13th St. Parking Structure
NW corner of 13th &
Hermosa Ave 3/18/2015 A‐1
Clark Building 861 Valley Drive 3/18/2015 A‐2
Valley Park Building 2521 Valley Drive 4/8/2015 A‐3
Kiwanis Shared Building Exterior Access and
Parking 2515 Valley Drive 4/8/2015 A‐4
Hermosa Beach Kiwanis Club 2515 Valley Drive 4/8/2015 A‐5 Hermosa Beach Rotary Club 2515 Valley Drive 4/8/2015 A‐6 Fire Department 540 Pier Ave 4/21/2015 A‐7
Police Department 540 Pier Ave 4/21/2015 A‐8
City Hall 1315 Valley Drive 4/21/2015 A‐9
Civic Center Exterior
Same as City Hall, Fire, and
Police 4/21/2015 A‐10
City Yard 679 Valley Drive 5/6/2015 A‐11
Base 3 Building
NE corner of 11th and
Valley Drive 5/6/2015 A‐12
South Park Building 425 Valley Drive 5/6/2015 A‐13
Community Center & Theater 710 Pier Ave 5/6/2015 A‐14
A summary assessment of these evaluation reports, which include ADA Inspection Plus, LLC’s findings, is provided on pages 10 through 58 of the 2015 Draft Transition Plan.
As shown in the summary assessment, we have added an “Updated Estimated Cost” column denoted in red font.
33 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 19
ESTIMATED COST
The total estimated cost to correct all the violations noted in the evaluation reports is on the order of approximately $1,150,468.
3. Citywide Disabled Parking Evaluation Reports - Off-Street Parking (Parking Lots)
The Hermosa Beach Citywide Disabled Parking report, dated June 13, 2017, was prepared by Creative Design Associates and Martin Brothers Construction Services (CDA-MBCS) (the “City-Wide Disabled Parking Report”). (See Attachment B of Appendix B.) The City of Hermosa Beach engaged the consultant to review eight (8) City-owned parking lots for compliance with applicable accessibility standards. The standards CDA-MBCS used in their evaluation included the 2010 ADA Standards for Accessible Design (ADAS) and the 2016 California Building Code (CBC). The report provided recommendations to correct non-compliant conditions. Cost to correct the noncompliant conditions was not provided.
CDA-MBCS team members evaluated the City parking facilities shown in the chart below, and prepared reports for each. An executive summary of these evaluation reports, which include CDA-MBCS’s findings, is provided on pages 1 through 21 of the Citywide Disabled Parking Report.
Off‐Street Parking Facility Address Report Date
Parking Lot A
1101 Hermosa (NW corner of 11th &
Hermosa Ave) 2/8/2017
Parking Lot B 59 13th Court 2/8/2017
Parking Lot L
Between 2nd St. and Herondo St. along
Valley 3/11/2017
Parking Lot M
Between 2nd and 3rd Street South of
PCH 2/8/2017
Parking Lot N 800 4th Street 2/9/2017 & 2/28/2017
Parking Lot O Kiwanis Club 2/9/2017
Parking Lot R Greenwood Park 2/9/2017
Access, Inc. found that many of the non-compliant conditions noted by CDA-MBCS have been corrected and updated the evaluation reports with edits in red, starting on page 22 of the Citywide Disabled Parking Report. Additionally, Access, Inc. provided estimated costs to correct the remaining non-compliant conditions. 34 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 20
ESTIMATED COST
The total estimated cost to correct all remaining violations noted in the evaluation reports is on the order of approximately $850,000.
4. Hermosa Beach On-Street Disabled Parking Report
Creative Design Associates and Martin Brothers Construction Services (CDA-MBCS) also evaluated selected on-street accessible parking spaces and provided a report dated, June 13, 2017 (“On-Street Disabled Parking Report”). (See Attachment C of Appendix B.) CDA-MBCS reviewed 28 accessible residential parking spaces for compliance with applicable accessibility standards (see chart below). A detailed breakdown of the parking space locations, assessment of compliance, and recommended corrections can be found on pages 11 through 21 of the On-Street Disabled Parking Report. No cost estimates were provided.
Parking Location Inspection Date
On‐street parking east of PCH 1050 1st Street 6/13/2017 On‐street parking east of PCH 436 Gentry 6/13/2017
On‐street parking east of PCH 439 Ocean View 6/13/2017
On‐street parking east of PCH 1105 3rd St. 6/13/2017
On‐street parking east of PCH 1115 17th St. 6/13/2017
On‐street parking east of PCH 1228 6th St. 6/13/2017
On‐street parking east of PCH 505 Hallowell 6/13/2017
On‐street parking east of PCH 1507 Golden St. 6/13/2017 On‐street parking west of PCH 1823 Valley Park Ave 6/13/2017 On‐street parking west of PCH 2162 Circle Drive 6/13/2017 On‐street parking west of PCH 731 10th St 6/13/2017
On‐street parking west of PCH 245 33rd St 6/13/2017
On‐street parking west of PCH 616 7th St. 6/13/2017
On‐street parking west of PCH 1441 Monterey 6/13/2017 On‐street parking west of PCH 823 Monterey 6/13/2017
On‐street parking west of PCH 412 Manhattan 6/13/2017 On‐street parking west of PCH 1811 Manhattan 6/13/2017 On‐street parking west of PCH 2440 Silverstrand 6/13/2017 35 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 21
On‐street parking west of PCH 218 28th St. 6/13/2017
On‐street parking west of PCH 360 33rd St. 6/13/2017
On‐street parking west of PCH 611 7th St. 6/13/2017
On‐street parking west of PCH 3010 Hermosa Ave. 6/13/2017 On‐street parking west of PCH 74 18th St. 6/13/2017
On‐street parking west of PCH 67 16th St. 6/13/2017
On‐street parking west of PCH 60 10th St. 6/13/2017
On‐street parking west of PCH 32 10th St. 6/13/2017
On‐street parking west of PCH 21 4th St. 6/13/2017
On‐street parking west of PCH 841 Manhattan Ave. 6/13/2017 On‐street parking west of PCH 2006 PCH 6/13/2017
The standards used in the CDA-MBCS evaluation included the 2010 ADA Standards for Accessible Design, the 2016 California Building Code, and the proposed 2011 Public Rights-of-Way Guidelines published by the U.S. Access Board (2011 PROWAG). In general, there is not one specific accessibility regulation or code that directly applies to on-street parking areas. The proposed PROWAG addresses only spaces that are marked or metered and have yet been adopted by the DOJ, which means they are not mandatory but are instead “best practices” guidelines. However, it was the consultant’s professional opinion that the on-street parking areas are required to be made accessible due to case law, even in the absence of specific scoping or technical requirements that directly apply.
Since the date of the CDA-MBCS on-street disabled parking report, the City has added additional on-street accessible parking spaces in the downtown district and updated many of the existing on-street accessible parking spaces with new striping and signage.
The report also provided guidance on receiving request by businesses and residences for additional on-street accessible parking spaces.
ESTIMATED COST
The total estimated cost to correct all remaining violations noted in the evaluation reports is on the order of approximately $52,500.
5. Citywide Facilities Assessment of Sidewalks and Curb Ramps 36 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 22
The Citywide Building and Facilities Condition Assessment CIP 13-664 ADA Sidewalks and Curb Ramps Evaluation report, dated May 2015, was prepared by Civil Source, Inc. (“Sidewalk and Curb Ramp Report”). (See Attachment D of Appendix B.) This assessment covered the pedestrian facilities for all streets including major arterials, collectors, and residential streets. The field data was input for each segment regarding physical characteristics, accessibility criteria, existing barriers, and any additional comments by the data collector. The criteria relating to accessibility included sidewalk width and alignment, the presence of curb ramps, ramp width and ramp slope. A detailed table of the numerous sidewalks and curb ramps evaluated for the Sidewalk and Curb Ramp Report begins on page 4 of that report.
Pedestrian facility improvements are mainly funded through the local Capital Improvement Program (CIP), Gas Tax Revenue Funds, the Regional Transportation Authority, and federally funded programs. Analyzing the design characteristics that promote accessibility will help jurisdictions to meet basic standards for accessibility. It also aids the process of prioritizing improvements and funding. Identifying these deficiencies will aid the City as it meets the needs of all sidewalk users.
In addition, pursuant to Hermosa Beach Municipal Code Chapter 12.08, most persons constructing commercial, industrial, and residential development projects must make improvements to the right-of-way. Section 12.08.010 states:
Except as provided in Section 12.08.020, any owner, lessee or agent or any other person or persons constructing or arranging for the construction of: (a) any commercial or industrial building or residential dwelling structure, or addition thereto, exceeding four hundred (400) square feet in floor area, or (b) any accessory building greater than fifty percent (50%) of the square footage of the existing main building, shall provide for the construction of Portland cement concrete curbs, gutters and sidewalks, street pavement between the gutter and center line of the street fronting the property, and pavement between the edge of pavement and center line of any alley adjoining the property, in accordance with the standard specifications of the City Engineer. (Ord. 02-1219, §1, May 2002).
Due to the number of curb ramps, driveways and sidewalks that have been improved since the report was authored, and potential changes to site conditions over time, it is recommended the Citywide Buildings and Facilities Condition Assessment CIP13-664 ADA Sidewalks & Curb Ramps Evaluation, dated May 2015, be updated or replaced with a new report.
37 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 23
ESTIMATED COST
The total estimated cost to correct all remaining violations noted in the evaluation reports is on the order of approximately $43,000,000. A new assessment report is estimated to cost approximately $150,000. The resulting combined cost is approximately $43,150,000.
E. TOTAL ESTIMATED COST
The updated costs to correct each violation listed in the ADA Assessment Reports were based on an average inflation rate of 2.21% per year. The updated costs do not include design, inspection, project and/or construction management and any contingencies.
Citywide Building Facilities $ 1,150,500.00
Citywide Disabled Parking (Off-Street) $ 850,000.00
Citywide Disabled Parking (On-Street) $ 52,500.00
Citywide Sidewalks and Curb Ramps $ 43,000,000.00
TOTAL ESTIMATED COST $ 45,053,000.00
F. PARTICIPATION OF INTERESTED PERSONS
The City created and involved the Access Hermosa Working Group (AHWG) to help comment on the 2015 Draft Transition Plan. Formed by a prior City Manager, from 2015 to November 2019 the AHWG met approximately once per month to discuss ADA access concerns and made suggestions to City staff. In 2019, the AHWG was given the opportunity to comment on the 2015 Draft Transition Plan and submitted feedback to City staff. AHWG comments November 2019 are included in Appendix C of this report.
For a number of reasons beyond the City’s control (including exigencies created by the COVID-19 pandemic), adoption of the proposed plan was delayed. As the purpose of the AHWG had up to that time been fulfilled, the AHWG ceased meeting and would convene again, upon request of the City Manager, to accomplish final approval of the City’s transition plan.
G. IMPLEMENTATION SCHEDULE
Appendix A to this report is the schedule to implement the corrections to the accessibility issues noted in this 2022 Transition Plan. The dates in the schedule are approximate and may change as funding becomes available and priorities may change over time.
38 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 24
H. RECOMMENDATIONS
This report functions as the City’s 2022 Self-Evaluation and ADA Transition Plan (“2022 Transition Plan”). Access, Inc. recommends the following as the City continues to demonstrate its good faith commitment to achieve program accessibility in measurable steps and goals:
1. Evaluation Report and Code Updates - The 2015 Draft Transition Plan and its ADA self-evaluation reports were performed in 2015. The other evaluation reports are based on inspections performed in early 2015 through 2017.
However, the current California Building Code cycle is dated July 1, 2021. It is therefore recommended that prior to making alterations to existing buildings and facilities, a new assessment report(s) with current code requirements be provided by a licensed architect and/or California Access Specialist (CASp). As projects are created the design shall include the current codes that are applicable at the time of design.
2. Self-evaluation - The City should also perform self-evaluations of areas described in Section F.1 of Part I, above, including: (1) employment policies and practices, (2) notice to the public of ADA requirements, (3) website accessibility, (4) temporary event permits and (5) Emergency Operations Center and on-scene operations. It is recommended the City review and update the Self-Evaluation documents and Transition Plan every 3 to 4 years.
3. Programs, Services and Activities - Staff must continue to evaluate the City’s programs, services and activities to ensure compliance.
4. Other City Facilities - Additional ADA assessments are required for City facilities that are not detailed in this 2022 ADA Transition Plan, including:
a. City Parks.
b. Buildings that are leased to Title III entities that provide public accommodations such as the storage facility adjacent to City Hall and the County Library.
c. Public buildings that are not occupied – the City should identify these buildings and indicate their current use. Such buildings that are not in use do not require ADA assessment reports, although if the use of the building(s) changes in the future, an ADA assessment is strongly recommended.
39 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 25
5. Commitment - Provide public notice of ADA requirements applicable to City (e.g., post notice at City Hall and on City website) and maintain commitment to access compliance.
6. Funding – the City has dedicated approximately $600,000 within its FY 2021-2022 budget for ADA consulting services and Capital Improvements Improvement Projects that include ADA accessibility components. It should continue to dedicate funds as they are available in future budget cycles to advance recommendations in this report.
As funding becomes available, it is recommended that priority be given to completing self-evaluations of programs and services (including (1) employment policies and practices, (2) notice to the public of ADA requirements, (3) website accessibility, (4) temporary event permits and (5) Emergency Operations Center and on-scene operations) and developing a more detailed implementation schedule for curb ramps and walkways serving government buildings and facilities, transportation, and places of public accommodation (e.g., bus stops), followed by walkways serving other areas.
7. Implementation - Update the implementation dates in the ADA reports and Transition Plan Schedule as budget and priority dictates.
8. On-going Maintenance Assessment - Periodic assessment related to the proper maintenance of all accessible features is required. This can be accomplished through future updates to facilities assessment report, sidewalk/curb ramp inventories, etc. The City also has a GoHermosa system for residents to report issues.
FINAL COMMENTS
The services provided by Access, Inc. to create this Transition Plan, a vast majority of which is based on reports prepared by other consultants, does not guarantee the completeness nor the correctness in the reports provided in this document. This report is a living document and should be updated as accessible features are brought into compliance with the ADA and CBC Standards.
40 City of Hermosa Beach February 8, 2022
On-Call ADA Consultant Services Page 26
Appendix A – Implementation Schedule
Appendix B – ADA Evaluation Reports
A. Hermosa Beach Draft Transition Plan (ADA Plus LLC)
A.1 Parking Structure (ADA Plus LLC)
A.2 Clark Building (ADA Plus LLC)
A.3 Valley Park Building (ADA Plus LLC)
A.4 Kiwanis Shared Building Exterior Access & Parking (ADA Plus LLC) A.5 Hermosa Beach Kiwanis Club (ADA Plus LLC)
A.6 Hermosa Beach Rotary Club (ADA Plus LLC)
A.7 Fire Department (ADA Plus LLC)
A.8 Police Department (ADA Plus LLC)
A.9 City Hall (ADA Plus LLC)
A.10 Civic Center Exterior (ADA Plus LLC)
A.11 City Yard (ADA Plus LLC)
A.12 Base 3 (ADA Plus LLC)
A.13 South Park (ADA Plus LLC)
A.14 Community Center & Theatre (ADA Plus LLC)
B. City of Hermosa Beach Citywide Disabled Parking (Creative Design Associates & Martin Brothers Construction Services)
C. Hermosa Beach On-Street Disabled Parking (Creative Design Associates & Martin Brothers Construction Services)
D. Citywide Building and Facilities Condition Assessment CIP 13-664 ADA Sidewalks and Curb Ramps Evaluation (CivilSource, Inc.) Appendix C – Access Hermosa Working Group Comments, November 2019 ATTACHMENTS:
41 Appendix A – Implementation Schedule
42 2022‐2025 2026‐2030 2031‐2035 2036‐2040 2041‐2045 2046‐2050 2051‐2055 2056‐2060 2061‐2065 2066‐2070 2071‐2075 2076‐2080 Parking Structure Building
Clark Building BuildingValley Park Building Building
Kiwani's Building Shared Exterior Building
Hermosa Beach Kiwanis Club BuildingHermosa Beach Rotary Club Building Fire Department Building
Police Department Building
City Hall Building BuildingCivic Center Exterior Building City Yard BuildingBase 3 Building BuildingSouth Park Building Building Community Center & Theatre BuildingCity Parks Parks
Citywide Disabled Parking (Parking Lots) Parking
Citywide On‐Street Disabled Parking Parking
Citywide Sidewalk & Curb Ramps Right‐of‐Way
City of Hermosa Beach
ADA Transition Plan ‐ Implementation Schedule ‐ DRAFT
February 8, 2022
Facility Name Facility Type Year
43Appendix A
Appendix C – Access Hermosa Working Group Comments,
November 2019
44 1 Appendix C
ADA TRANSITION PLAN COMMENTS
BY
ACCESS HERMOSA
November 2019
13th Street - Parking Structure
The Access Hermosa Work group has the following comments:
• Entrance into parking structure is too steep (2% grade change). • Handicap entrance (1), cars only, no sidewalk to structure (no ramp provided). • 10 handicap spots in total (4 L2, 3 L2, 3 L4).
• Trashcans (L4) in the way of path of travel.
• Hotel parking located at the subterranean level/bottom level (one handicap space for hotel guests/employees only).
• No sidewalk/walkway for handicap access for those coming from the bottom floor to L2.
Valley Park Building - 2521 Valley Dr.
The Access Hermosa Work Group has the following comments:
• Picnic areas need better sidewalk access. Most of the picnic areas are in the grass which make it very difficult for people in wheel chairs, strollers, and walkers to reach. • All stairways to the park need ramps with handrails.
• The park needs solar lights. While the park does have lights at night, they only light up some areas of the park. Solar lights would provide more lighting to the park at night and would prevent suspicious activity.
• BBQ areas need at least one picnic table that are lower for wheel chair access. • All BBQ areas need to be leveled so wheel chairs can have access to the picnic areas. • All sinks in the picnic areas need to have wheel chair access. • At least one BBQ needs to be lowered for wheel chair access.
The Access Hermosa Work Group has the following comments regarding the men's and women's restrooms:
• Park restrooms all need to provide disable access for adults and children. • The bathrooms need an outside camera for monitoring bathroom activity.
Kiwani's Building South - 2515 Valley Dr.
The Access Hermosa Work Group has the following comments:
• The building needs disable bathroom repairs and upgrades including wheel chair access with upgraded door and push button door access.
• The front door is wide enough for wheel chairs access but the doors need push button door opener.
• A handrail may be needed on one side of the entrance. • The south side door needs to have a ramp with a door wide enough for a wheel chair access this door leads to the kitchen.
45 2 Appendix C
• The north side door needs a ramp with hand rails leading outside. • Next to the north side door, more disable parking is needed. • The street parking on Valley Dr. needs disable parking near the stairs. The stairs needs a ramp for wheel chair access and with handrails.
Kiwani's Building North (Hermosa Beach Rotary) - 2515 Valley Dr.
The Access Hermosa Work Group has the following comments:
• The building has two front doors and both need to be upgraded to larger doors for wheel chair access with push button door openers.
• Bathrooms need to be upgraded with wider doors with push button door openers. • Disable parking is needed on Valley Dr. in front of the Rotary Building. • Stairs in front of the Rotary entrance needs a ramp with rails. • Area in front of the Rotary Building Northside walkway near a tree needs to be leveled so wheel chairs do not get off the walkway.
• Rotary building only has outdoor access from the front doors in case of a fire a back door access maybe needed.
City Hall Building - 1315 Valley Dr.
The Access Hermosa Work Group has the following comments:
• Automatic door needs to be fixed.
• Ramp to City Hall is too far away (East of Library – difficult to see ramp if you park in front of City Hall).
Base 3 Building - 11th Street & Valley Dr.
The Access Hermosa Work Group has the following comments:
• There are 2 ADA parking spaces in the southwest corner of the parking lot and 1 ADA parking space curbside on 11th street west of the building. • There is a ramp from the 2 spaces in the lot but it leads to a very long and serpentine sidewalk path to the main entrance on the east side of the building. • There is no painted path anywhere on the premises.
• The curbside space also has no painted path.
• On the east side of the building there is the main entrance, a 36" door with appropriate clearance, but no opening device.
South Park Building - 425 Valley Dr.
The Access Hermosa Work group had the following comments:
• Portions of the sidewalk need leveling.
• Park tables need to be raised.
• The BBQ need to be lowered.
• The bathrooms need major disable remodeling.
• Looking at the building from the lower front, the stairs to the right need a ramp.
Community Center and Theatre – 710 Pier Avenue
The Access Hermosa Work Group had the following comments:
• Entrance door 1 has an automatic door, which closes slowly enough to allow a wheelchair to get through safely. The lip is safe to rollover.
• The doors for the men’s and women’s restrooms in the Main Building and entrance doors 2, 4, and 6 are not automatic. The doors close too fast. The lips are safe to rollover. 46 3 Appendix C
• Entrance door 4 does not have a ramp, which makes it wheelchair inaccessible. • Entrance doors 3 and 8 do not automatically open. These doors close too fast to allow a wheelchair to get through safely. The lips are safe to rollover. • Entrance door 7 does not automatically open. The door closes slowly enough, and the lip is safe to rollover.
• Entrance door 5 automatically closes. It closes slow enough to allow a wheelchair to get through safely. The lip is safe to rollover.
• The south corridor door from the theatre does not automatically close. It closes too fast to allow a wheelchair to get through safely. The lip is okay to rollover. • The museum entrance and exit doors were locked, so an assessment was not possible. 47 Appendix B – ADA Evaluation Reports
A. Hermosa Beach Draft Transition Plan (ADA Plus LLC)
48 City of Hermosa Beach
Title II Comprehensive Evaluation and Transition Plan
Adopted
(Date)
REVISION 1 09/24/2015
49 City of Hermosa Beach
Transition Plan
Table of Contents
A. Introduction
1. Summary
a) Federal Accessibility Requirements
b) Title II Requirements
c) Purpose of the Self-Evaluation
d) Purpose of the Transition Plan
e) State of California Five Phases of Access Compliance (1) PHASE I: COMMITMENT Agency Head or Department Director demonstrates a commitment to Access Compliance.
(2) PHASE II: SELF-EVALUATION Complete Self-Evaluation and develop Transition Plan to identify and resolve accessibility issues. (3) PHASE III: TRANSITION Prepare budget and correction plan to submit to Department of Finance (DOF) for approval.
(4) PHASE IV: IMPLEMENTATION Implement all items in the SelfEvaluation and remove structural noncompliance items of the Transition Plan.
(5) PHASE V: ONGOING SUPPORT Continue involvement and
resolution of all problems and issues related to ADA. Provide periodic assessment related to the proper maintenance of all accessfeatures B. Self-Assessment
1. Introduction
2. Findings
a) Parking Structure
b) Clark Building
c) Valley Park Building
d) Kiwanis Shared Exterior
e) Kiwanis South
f) Kiwanis North
g) Fire Department
h) Police Department
i) City Hall
j) Civic Center Exterior
k) City Yard
l) Base 3
m) South Park
n) Community Center & Theatre
2 | P a g e
50 City of Hermosa Beach
Transition Plan
C. Transition Plan
1. Facilities
a) Barrier Removal Priorities
b) Prioritizing Access
c) Priorities for Barrier Removal within Facilities
d) Transition Plan for Facilities
e) Phasing Schedule for Facilities
D. Pedestrian Rights-of-Way (PROW)
1. Surveys of Existing PROW Conditions
2. Pedestrian Rights-of-Way Prioritization
3. Time Period for Pedestrian Rights-of-Way Improvements
4. PROW Construction Details
5. Accessibility during construction
6. Street or Sidewalk Closure
7. On-Street Accessible Parking
8. Citizen Request Process
3 | P a g e
51 City of Hermosa Beach
Transition Plan
A. Introduction
1. Summary
The American with Disabilities Act (ADA) enacted on July 26, 1990, is a Federal Civil Rights law prohibiting discrimination against individuals on the basis of disability. The ADA consists of five titles providing protections in the following areas: Title I – Employment, Title II - State and Local Government Services, Title III - Public Accommodations, Title IV – Telecommunications, Title V - Miscellaneous Provisions. Title II of ADA pertains to the programs, activities, and services provided by public entities, such as State departments of transportation. The ADA states that its purpose is to provide a "clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities." Congress emphasized that the ADA seeks to dispel stereotypes and assumptions about disabilities and to assure equality of opportunity, full participation, independent living, and economic self-sufficiency for people with disabilities. Title II of ADA provides that, “…no qualified individual with a disability shall, by reason of such disability, be excluded from participation in or be denied the benefits of the services, programs, or activities of a public entity, or be subjected to discrimination by any such entity” (42 USC. Sec. 12132; 28 CFR. Sec. 35.130). A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. In other words, a public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. The ADA states that a public entity must reasonably modify its policies, practices, or procedures to avoid discrimination against people with disabilities.
This report will assist City of Hermosa Beach to identify physical barriers of accessibility and to develop barrier removal solutions that will facilitate the opportunity of access to all individuals. This 2015 plan describes the process by which facilities were evaluated for compliance with the ADA; presenting the findings of that evaluation; and providing recommendations to ensure compliance. This section provides an overview of the requirements for developing the Self-Evaluation and Transition Plan and outlines the plan development process. Subsequent sections will describe and evaluate policies and programs and will establish the relationship between physical and programmatic barriers to accessibility
2. Federal Accessibility Requirements
The Department of Justice published revised regulations for Titles II and III of the Americans with Disabilities Act of 1990 "ADA" in the Federal Register on September 15, 2010. These regulations adopted revised, enforceable accessibility standards called the 2010 ADA Standards for Accessible Design "2010 Standards" or "Standards". The 2010 Standards set minimum requirements – both scoping and technical – for newly designed and constructed or altered State and local government facilities, public accommodations, and commercial facilities to be readily accessible to and usable by individuals with disabilities. Adoption of the 2010 Standards also establishes a revised reference point for Title II entities that choose to make structural changes to existing facilities to meet their program accessibility requirements; and it establishes a similar reference for Title III entities undertaking readily 4 | P a g e
52 City of Hermosa Beach
Transition Plan
achievable barrier removal. The Department is providing this document with the official 2010 Standards in one publication. The document includes: The 2010 Standards for State and local governments, which consist of the Title II regulations at 28 CFR 35.151 and the 2004 ADAAG at 36 CFR part 1191, appendices B and D; The 2010 Standards for public accommodations and commercial facilities, which consist of the Title III regulations at 28 CFR part 36, subpart D, and the 2004 ADAAG at 36 CFR part 1191, appendices B and D. The Department has assembled into a separate publication the revised regulation guidance that applies to the Standards. The Department included guidance in its revised ADA regulations published on September 15, 2010. This guidance provides detailed information about the Department’s adoption of the 2010 Standards including changes to the Standards, the reasoning behind those changes, and responses to public comments received on these topics. The document, Guidance on the 2010 ADA Standards for Accessible Design, can be downloaded from www.ADA.gov
a) Title II Requirements
Title II of the ADA covers programs, activities, and services of public entities. It is divided into two subtitles, subtitle A of title II, which is implemented by the Department of Justice's title II regulation. Subtitle B, covering public transportation, and the Department of Transportation's regulation implementing that subtitle.
Subtitle A is intended to protect qualified individuals with disabilities from discrimination on the basis of disability in the services, programs, or activities of all State and local governments. It additionally extends the prohibition of discrimination on the basis of disability established by section 504 of the Rehabilitation Act of 1973, as amended, to all activities of State and local governments, including those that do not receive Federal financial assistance. By law, the Department of Justice's title II regulation adopts the general prohibitions of discrimination established under section 504, and incorporates specific prohibitions of discrimination from the ADA.
Subtitle B is intended to clarify the requirements of section 504 for public transportation entities that receive Federal financial assistance. Also it extends coverage to all public entities that provide public transportation, whether or not they receive Federal financial assistance. It establishes detailed and complex standards for the operation of public transit systems, including commuter and intercity rail (AMTRAK). The Department of Transportation is responsible for the implementation of the second subtitle of Title II and issued a regulation implementing that subtitle. Public entity. A public entity covered by title II is defined as -- 1) Any State or local government; 2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
5 | P a g e
53 City of Hermosa Beach
Transition Plan
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include --
1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees; 3) Whether the entity receives significant assistance from the government by provision of property or equipment; and 4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
b) Purpose of the Self-Evaluation
Title II regulations also require public entities, by January 1993, to evaluate their current services, policies and practices, and their effects, that "do not or may not meet the requirements [of Title II of the ADA],” and if modification of services, policies, and practices is needed to achieve compliance, make the necessary modifications. Unlike transition plans, the regulations require selfevaluation plans to be developed by every public entity regardless of the number of employees it has. The regulations require public entities to provide an opportunity for the public to participate by submitting comments on self-evaluation plans, and public entities with 50 or more employees are required to keep these plans on file for three years for public inspection, along with a list of the interested people consulted in developing the plan, a description of the areas examined, and the problems identified, and a description of any modifications made. As with transition plans, agencies that already completed self-evaluation plans under Section 504 of the Rehabilitation Act are required to draft a self-evaluation plan and comply with the plan requirements only for those policies and practices that were not included in the agency's Section 504 plan. c) Purpose of Transition Plan
The development of a Transition Plan is a requirement of the federal regulations implementing the Rehabilitation Act of 1973, which requires that all organizations receiving federal funds make their programs available without discrimination toward people with disabilities. The Act, which has become known as the "civil rights act" of persons with disabilities, states that: No otherwise qualified handicapped individual in the United States shall, solely by reason of handicap, be excluded from the participation in, be denied the benefits of, or be subjected to discrimination under any program or activity receiving federal financial assistance. (Section 504). The Transition Plan, as required by 28 CFR
35.150 (d), must include at a minimum, the following: Identification of the physical barriers that limit accessibility to the public entity’s programs, services, or activities for people with disabilities, Description of the methods to be used to make the facilities accessible, A schedule for making the necessary modifications, including a yearly schedule and, The name and contact information for the public official responsible for implementation of the Transition Plan. As required by Title II of ADA, 28 CFR. Part 35 Sec. 35.105 and Sec. 35.150,
6 | P a g e
54 City of Hermosa Beach
Transition Plan
d) State of California Five Phases of Access Compliance (1) PHASE I: COMMITMENT Agency Head or Department Director demonstrates a commitment to Access Compliance.
ADA Coordinator
Identifying an ADA Coordinator: This individual should: Communicate with DOR to complete the mandatory Self-Evaluation. If necessary, a contract may be initiated with an access consultant to facilitate the process. Recommend necessary changes to policies affecting people with disabilities including a complaint process. Designate an individual to resolve program access issues including alternative format requests and equivalent facilitation. This may be the ADA Coordinator. Personnel specified above should perform periodic assessments of ADA compliance status committing to continuous improvement and proper maintenance of accessibility programs and services including: - Revising forms and documents; - Modifying emergency evacuation plans; - Identifying training needs within the organization to prevent discrimination. Promote the establishment of the departmental Disability Advisory Committee as an independent body dedicated to ensuring equal treatment for persons with disabilities.
Accessibility Specialist CGC 4459.5
BUILDING OR FACILITY: Identifying the agency official responsible for the Self-Evaluation/Transition Plan project. Designating an Accessibility Specialist to monitor renovation and construction projects identified in the Self-Evaluation phase. Once established, this position will be responsible to: - Determine access compliance status of all leased buildings or minor capital outlay projects. - Assist the project leader in identifying barriers while completing the Self-Evaluation. - Produce a Transition Plan effectively eliminating all barriers identified in the Self-Evaluation. - Ensure that an employees' needs assessment is completed and delivered to the architectural professional to be incorporated into the construction design. - Submit complete and correct project packages to DSA for plan review and approval (see Project Submittal Checklist - www.dsa.dgs.ca.gov/projectsubmittalprocess/ checklist.htm). - Monitor barrier removal and verified report as each phase of work progresses.
Collaboration with a licensed California architect as needed is expected. (2) PHASE II: SELF-EVALUATION Complete Self-Evaluation and develop Transition Plan to identify and resolve accessibility issues.
ADA Coordinator
EVALUATE PROGRAMS AND SERVICES: Evaluate program accessibility (1) Fill out Self-Evaluation survey to identify program accessibility needs. (2) Develop Transition Plan to resolve issues and remove barriers within each program. (3) Establish timelines for completion of modifications identified in Transition Plan. (4) Establish procedures for follow up to ensure proper maintenance of access features. (5) Retain records of Self-Evaluation on-file for public inspection and comment for 3 years. Solicit individual input from employees with disabilities to ensure that their needs and expectations are met through this process. Consult with departmental Disability Advisory Committee regarding issues affecting persons with disabilities. Provide design guidance to Accessibility Specialist or architect developing the access plan. Establish an evacuation plan that includes provisions for persons with disabilities. Evaluate all policies, programs, services, activities, practices and privileges to comply with ADA requirements. Organize disability awareness and sensitivity training for all employees. Provide specialized training for supervisors and managers. Establish multi-level complaint process and grievance procedure.
7 | P a g e
55 City of Hermosa Beach
Transition Plan
Accessibility Specialist CGC 4459.5
BUILDING OR FACILITY: With guidance from the Accessibility Specialist, describe in detail the physical obstacles that limit program or activity accessibility by individuals with disabilities. Begin to evaluate the cost, timeframe and issues associated with the removal of barriers discovered by the survey. DSA is requiring facility owners to confer with qualified universal design consultants before completing the Transition Plan and subsequent architectural drawings.
(3) PHASE III: TRANSITION Prepare budget and correction plan to submit to Department of Finance (DOF) for approval.
ADA Coordinator
BUDGET PROGRAMS AND SERVICES: After all comments are compiled and considered, the published Self-Evaluation becomes the foundation for the access compliance Transition Plan. Programmatic collaboration on the completion of these plans is available through DOR. Architectural guidance is available through DSA. The Transition Plan describes all corrections needed and the timeframe within which the project will be completed. When proposal is complete, a budget item is prepared for submission to DOF for approval.
Accessibility Specialist CGC 4459.5
BUILDING OR FACILITY: The Accessibility Specialist coordinates the completion of the structural elements of the Transition Plan by providing the architect/designer with a report on the following: - Describe in detail the methods used to achieve facility accessibility; this includes physical alterations, program modifications and assignment changes. - Provide an opportunity for comments from employees, the DAC, the disability community and the general public. - Produce a timeline for achieving access compliance. - Initiate development of the architectural plans for the needed modifications. Funding is allocated for the correction plan: - Major capital outlay projects must be approved through DOF. - Minor capital outlay and discretionary funds are identified through the departmental budgetary process. All surveys and mitigation plans must be reviewed and approved by: - DGS, Real Estate Design Services (RESD), if the building is state leased - The appropriate DSA Regional Office, if the building is state owned. Retain the final Transition Plan on file for public inspection (4) PHASE IV: IMPLEMENTATION Implement all items in the SelfEvaluation and remove structural noncompliance items of the Transition Plan.
ADA Coordinator
IMPLEMENT CHANGES IN PROGRAMS AND SERVICES: The implementation phase achieves the goals established in the Self-Evaluation and Transition Plan. - All barriers to programs, services and activities are removed. - Alternative formats and/or accommodations are employed. Examples: large print, audiotapes, electronic format, voice recognition, interpretive services. - Signage and other methods of communication are initiated to publicize the availability of these modifications and alternatives. - Initiate new policies and procedures developed during the Self-Evaluation and Transition Plan phases and facilitated by plan implementation
Accessibility Specialist CGC 4459.5
BUILDING OR FACILITY: The implementation phase ensures that building or facility accessibility is achieved. - All physical barriers are removed from the facility. - All recommendations for modifications 8 | P a g e
56 City of Hermosa Beach
Transition Plan
to achieve accessibility are implemented. Examples: paths of travel, restroom facilities, signage, automatic door openers and parking areas. - Each phase of the Transition Plan will be signed off as it is completed. - Once the project is finished, the signed Transition Plan will be kept on file for public inspection. When the project is finished, a verified report from a private architect is signed to indicate: - Mitigation of the previously existing conditions described in the Transition Plan. - The work performed complies with current code and policies adopted by DSA and/or DOR. (5) PHASE V: ONGOING SUPPORT Continue involvement and
resolution of all problems and issues related to ADA. Provide periodic assessment related to the proper maintenance of all accessfeatures ADA Coordinator
PROVIDE PROGRAM SUPPORT FOR PROGRAMS AND SERVICES: After the program and facility modifications based on the Transition Plan have been completed, the maintenance and quality control phase begins. - Complete a final report reflecting access compliance status and retain it on file for public inspection and comments. - Administer periodic evaluations of the agency's access compliance status. - Conduct scheduled maintenance of all access features. - Continue resolving all access related problems and issues as they surface. - Facilitate the inclusion of accessibility issues in all construction, modernization or facility repair projects.
Accessibility Specialist CGC 4459.5
BUILDING OR FACILITY: Maintain proper operation and upkeep of all accessibility features. - Adhere to the established maintenance schedule of all mechanical features. - Ensure that paths of travel are adequately maintained. - Ensure that accessibility features remain foremost concerns when alterations, modifications and new construction are contemplated. - Inspect all repairs or additions to the building or facility for operable accessibility features.
B. Self-Assessment
1. Introduction
In order to perform the required self-evaluation for the City of Hermosa Beach’s public facilities in regards to adherence to the Americans with Disabilities Act, a collection database was developed. A preliminary checklist was first created from the specific requirements for public facilities outlined in the Americans with Disabilities Act, to provide a starting point for the collection database. The selfevaluation consisted of visiting eleven public facilities within the City of Hermosa Beach: Base E, City Hall, City Yard, Clark Building, Community Center & Theatre, Kiwanis club-North Building, Kiwanis clubSouth Building, Parking Structure, Police & Fire Department, South Park, and Valley Park Building.
Aspects of each facility were observed, tested, and measured to ensure compliance with ADA Standards. What follows below is a conclusive summary assessment or evaluation of where the City of Hermosa Beach complies with ADA standards and where the City of Hermosa Beach needs further work in order to comply.
2. Findings (#1-High Priority-#4-Low Priority)
9 | P a g e
57 City of Hermosa Beach
Transition Plan
a) Parking Structure
The Parking Structure is located on the NW corner of 13th St. and Hermosa Ave Violations:
Parking Structure
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations:
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
Exterior:
Site Arrival Points: Section 1 Cost Estimate: $5000 - For detectable warning devises only. $5,662.50 Accessible
Route
Pg. 6-7,
Item A
CBC 11B206East Access - From Hermosa Ave. (Cross Slopes violations).
West Access form Beach (Cross Slope / Curb Ramp
violations) At least one accessible route shall be provided within the
boundary of the site.
2 Detectable
Warning Devices
Pg. 7,
Item B
CBC 11B705.1.2.5Detectable warning devices shall be provided (36" minimum width) at hazardous vehicular areas per CBC only.
3 Overall Parking: Section 2 Cost Estimate: $500 - Signs Only. $566.25 Sufficient
Accessible
Parking
Pg. 9,
Item A
11B-208.1 Not Sufficient Accessible Parking Provided.
Provide proper number of ADA parking
spaces.
1 Sufficient Number
of Vanaccessible
Parking
Pg. 9,
Item B
CBC 11B208.2.4Findings - No Van Accessible Parking Provided.
Six or a fraction of six parking spaces shall be
VAN ACCESSIBLE
1 Tow Away Sign Pg. 10,
Item C
CBC 11B502.8Not Provided / Provide one at each driveway entrance. Provide a
new "Unauthorized Vehicle Tow Away" (R100B)
1 Level 3 –
Parking Spaces:
Section
3(B)
Cost Estimate: $9,000 - Charging station, Striping and Signage 10,192.50 Wheel stop or
Curb
Pg.19,
Item A.2.
11B-208.1 Non-Compliant
Provide Wheel Stop at PS 3.2 to prevent encroachment
on accessible route
1 Accessible spaces
properly
marked
Pg. 19-
20, Item
B.2.
11B-208.1 40" +/- all 3 signs. Missing "Minimum FINE $250" sign.
Mounting height of 60" min from ground surface to bottom of sign not
provided
2 Accessible Stall
Striping
Pg. 20-
22, Item
D.2.
11B-208.1 Length and width of Parking not done properly 3 Level 2 –
Parking Spaces:
Section
3(C)
Cost Estimate: $4000 - Slope modifications, Striping, Cane Protection & Signage. $1500 - To add at least (2) accessible parking spaces on the lower level parking.
$4,530.00
$1,698.75
Wheel Stop or
Curb
Pg. 25,
Item A.3.
11B-208.1 Non-Compliant.
Provide Wheel Stop to prevent encroachment into
accessible route.
1 Accessible Spaces
Properly
Marked
Pg. 25,
Item B.3.
11B-208.1 40" - 55" +/- all 3 signs on level 2.
Increase Height to 60”min from
ground
2 Accessible
Parking and
Adjacent aisle
Slope
Pg. 26,
Item C.3.
CBC 11B502.4
2.7% in Access Aisle.
Repave to be no greater than (2%) max slope
1 Accessible Stall
Striping
Pg. 27,
Item D.3
11B-208.1 88" +/- / Striping not measured 108" centerline to centerline.
See Level 3 Parking Spaces for requirements.
1 Path of Travel Pg. 28-
29, Item
E.3.
11B-307.2 Need a clear Path of Travel 1
Upper Level /
Hermosa Ave
Entrance/Exit:
Section
3(D)
Cost Estimate: $7000 - Design, striping, signs & slope modifications $7,927.50 Wheel Stop or
Curb
Pg. 30,
Item A.4.
CB
C
11B
-
502.7.1
Forced to walk behind vehicle other than their own. The spaces must be located so a person with a disability is not compelled go behind other parking spaces.
1 Accessible
Spaces Properly
Marked
Pg. 32,
Item B.4.
11B-208.1 Findings - 36" / Mounting height of 60" min from ground surface to bottom of sign not provided & Incorrect
Sign.
2 10 | P a g e 58
City of Hermosa Beach
Transition Plan
Violations:
Parking Structure
Pg.
Ref.,
Item
Number
Code
Reference
Comments:
Recommendations:
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
Accessible
Parking and
Adjacent aisle
Slope
Pg. 33,
Item C.4.
11B-208.1 Violations Found: Exceeds 1:48 (2%) in parking and/or access aisles (Findings - 2.4% / 3.0% / 3.5% / )
1 Accessible Stall
Striping
Pg. 34-
35,
Item
D.4.
11B-208.1 Findings - 96" / Striping not measured 108" centerline to centerline. Findings - Lines not painted BLUE. Typical all (4)
spaces. Findings - No Access Aisles provided
1 Curb Ramps: Section 4 Cost Estimate: $5000 - For North curb ramp approach from top. $5,662.50 Slope Pg. 36,
Item A
CBC 11B406Construction of this curb ramp does not allow for a complaint path of travel when entering the ramp from the north side. 2 Detectable
Warnings
Pg. 37,
Item B
CBC 11B406.5.12Findings - No Detectable Warning Devices provided See "Accessible Routes Exterior" section.
3 Accessible Routes
Exterior:
Section 5 Cost Estimate: $3000 - Replace concrete $3,397.50 Walks Pg. 38-
41,
Item A
11B-403 Cross slopes too great 2
Changes in
Level
Pg. 41-
42,
Item B
CBC 11B303
Findings - 1" change in elevation at sidewalk join 1
Elevator: Section 6 Cost Estimate: $2500 - For Landing and Door-jam identification. $2,831.25 Elevator Door
Landings and
Clear Floor
Space
Pg. 44,
Sectio
n A
11B-407.2 Findings - Level 3 elevator approach 3.9%
Clear Floor or Ground Space shall be provided at call
controls.
3 Elevator hoist
way
Pg. 44-
45,
Sectio
n B
11B407.2.3.1
Findings - Not Provided on first floor jams. These shall have a STAR to identify the "Main" floor.
2 11 | P a g e
59 City of Hermosa Beach
Transition Plan
b) Clark Building
The Clark Building is located 861 Valley Dr.
Violations: Clark
Building
Pg. Ref.,
Item
Number
Code
Referenc
e
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
Exterior Site Access:
Parking: Section 2 Cost Estimate: $500-signs only $566.25 Signage Pg.8, Item C CBC
11B502.8
Unauthorized Vehicle Tow Away Sign. Provide a new R100B sign with the proper information. Reposition Parking Spaces
2 Accessible Routes: Section 3 Cost Estimate: $6000 $6,795.00 Accessible Route Pg. 11, Item
A
CBC 11B502.7Parking is not placed to connect to the shortest possible accessible route to the accessible entrance/s.
1 Wheel Stop or
curb to prevent
vehicles from
walking surface
Pg. 11, Item B CBC
11B-502.7.1
Forced to walk behind vehicle other than their own. No
bumper or curb in place to prevent encroachment of cars.
Move the parking spaces out and provide an accessible
route in front of
the existing parking spaces.
1 International
Symbol of
Accessibility
Pg. 13-15,
Item C
2013 CBC
11B-502.6.
Incorrect Signs & Sign Height. Replace Signs and Place
at Proper Height and distance.
1 Spaces and
adjacent aisle
exceeding
1:48(2%)
Pg. 17-18,
Item D
CBC
11B502.4
Slope greater that 2%. Repave 1
Accessible Stall
Striping
Pg. 19-23,
Item E
CBC
11B.50
2 Striping not measured centerline to centerline. Stripe accessible parking space according to code.
1 Curb Ramps: Section 4 Cost Estimate: $5000- New curb ramp required $5,662.50 Slope Pg. 24-25,
Item A
CBC
11B- 406
Cross pedestrian traffic parallel to the street creates a cross slopes of 21%. This is a very dangerous condition. Need new Ramp
1 Bottom Turning
Space
Pg. 26, Item B CBC
11B406.3.2
Recommended modified layout for proper turning space. 2 Accessible Routes
Exterior:
Section 5 Cost Estimate: $6500 for new ramp with landings & railings. $7,361.25 Accessible routes
of Travel
Pg. 28-29,
Item B
CBC -
11B-206.2.2
No accessible route to Clark Field. Provide accessible route of travel to and from all accessible buildings and within accessible
facilities.
2 Changes in
Level
Pg. 29-31,
Item C
CBC
11B- 303
1" at top of ramp - Not on an accessible route -
hazardous condition for pedestrian ways need to be
leveled.
2 Ramps: Section 6 Cost Estimate: $7500 Ramp design/ $4500 for 5% max walk with 6" curb edge protection.
$8,493.75/
$5,096.25
Slope Pg. 33, Item A CBC
11B- 405
8.5% - 11.2% ramp slopes. New Ramp 1
Landings /
Ramps
Pg. 33, Item B CBC
11B405.7
Included in Slope 1
Railings / Curb Pg. 33, Item
C-F
CBC
11B405.8
Included in Slope. Ramps shall provide hand railing on
each side of ramp.
1 Stairways: Section 7 Cost Estimate: $3000 for railing and contrasting stripe. $3,397.50 Risers Pg. 36, Item
B
11B-504.2 Bottom riser is less than 4" / All rises are not equal. 4 Hand Railings Pg. 36, Item C 11B-505.2 No Hand railing provided - Ramp is recommended to be provided at this location as well. Handrails shall be provided on both sides of stairs and ramps.
4 Stair Striping Pg. 38, Item
D
11B-504.4.1 It is recommended to provide contrasting stripe. 4 Entrance Doors: Section 8 Cost Estimate: $3500 for door landing and door adjustments $3,963.75 12 | P a g e 60
City of Hermosa Beach
Transition Plan
Violations: Clark
Buildin
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
Door Closure Pg. 39, Item
A
CBC 11B404.2.8.1
3 Seconds 90deg to12deg 3
Pull/Push Force Pg. 40, Item
B
CBC 11B404.2.9The pressure exceeds 5lbs on the left door leaf. It should be 5lbs after the release of the push bar.
3 Maneuvering
Space
Pg. 41-42,
Item C
CBC 11B4048.8% ramp in level maneuvering space. The floor or ground space within the required clearances shall be level and clear. 3 Threshold Pg. 39, Item
D
CBC 11B404.2.5Information Only: Provide or modify door threshold or raise maneuvering space so that the floor or landing shall not be more than 1/2" lower than the top of the threshold of the doorway. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2.
3 EXIT Sign Pg. 39, Item
E
CBC 11B703
Not provided. Provide tactile EXIT sign at exit doors. 3 Meeting Room
Door:
Section 9(A Cost Estimate: $200 $226.50
Door Hardware Pg. 45, Item
B.1
28 CFR
Part 36 App.
A - 4.13.9
Twist Type door knob on meeting room door. Exit door in kitchen has a twist door knob as well. Closet door has a twist door knob. It is recommended to provide a lever type door handle, mounted between 34" and 44" above finish floor. 2 Kitchen Door: Section 9(B Cost Estimate: $250 $283.13 Door Hardware Pg. 47, Item
A.2
28 CFR
Part 36 App.
A - 4.13.9
Twist Type door knob. It is recommended to provide a lever type door handle, mounted between 34" and 44" above finish floor. 2 Accessible
Routes
Interior:
Section 11 Cost Estimate: $250 - Relocate fire extinguisher cabinet $283.13 Obstacles in
Path of Travel
Pg. 51-52,
Item A
11B-307.2 Fire Extinguisher is in the path of travel. Relocate fire extinguisher cabinet.
3 Reach
Ranges for
Operable
Parts:
Section 12 Cost Estimate: $250 $283.13
Reach Range
Requirements
Item A
11B-308.2 Lower thermostat to 48" to top of control. Does not meet "Safe Harbor" Requirements of 54" to top if installed before March 15, 2012. Need to place things within proper Reach Range
2 Kitchens &
Kitchenettes:
Section 13 Cost Estimate: $1500 for new accessible sink $1,698.75 Sinks and Knee
Clearance
Pg. 56-58,
Item A
11B-212.3 Existing sinks do not meet compliance with at least (1) sink at 34" high AFF and required knee clearance. Need at least (1) sink at regulation height
3 Restroom Doors: Section 14 Cost Estimate: $4000 - New doors and reconfigure. $4530.00 SignageWomen’s
Pg. 60-61,
Item A
703.7.2.6 Tactile Sign Not Provided / Geometric sign not provided Doorways leading to toilet rooms and bathing rooms. Provide Proper Signage.
1 Signage- Men’s Pg. 61, Item
B
Same as
Above
Tactile Sign Not Provided / Geometric sign not provided. Same as Above
1 Door Hardware Pg. 61-62,
Item C
28 CFR
Part 36 App.
A - 4.13.9
Women's Restroom and Men's Restroom door have twist type door knobs - Replace with lever type door. Handles and install at proper distance.
1 Accessible Door Pg. 63-64,
Item D
CBC
11B-404
Both restroom doors are less the 32" minimum clear. Provide 32" clear width from face of door at 90deg to opposite stop.
Door 3' wide by 6'-8" shall be provided.
1 Maneuvering
Space
Pg. 65-66,
Item G
CBC 11B404Women's Restroom Door - 35" on the pull side of door. Men's Restroom door less than 18" strike side clearance on pull side of door. The floor or ground space within the required
clearances shall be level and clear.
1 Strike Side
Clearance
Pg. 67-68,
Item H
11B404.2.4.311" recessed door at Men's restroom. - Door has latch and closure and 12" at less than 8" is required. Maneuvering clearances for forward approach shall be provided.
2 Door Closure
Height
Pg. 68, Item
I
CBC 11B404.2.3Both restroom doors in violation. Modify door closure to be a minimum of 78" clear above finish floor or ground.
3 Smooth Surface
on Door Bottom
Pg. 68, Item
J
CBC 11B404.2.10Both door have stop mounted in the smooth 10" area. Remove door stops. Provide a 10" smooth panel on the push side of 3 13 | P a g e
61 City of Hermosa Beach
Transition Plan
Violations: Clark
Buildin
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
door or gate. Cap all voids at top of smooth panel if void is present.
Women’s
Restroom:
Section
15(A)
Cost Estimate: $15,000 $16,987.50
Required
Clearance at
Water Closet
Pg. 74, Item
B.1
11B-604.3 No accessible compartment provided. Existing compartments - Non Compliant. This entire restroom needs to be redesigned to meet current accessibility requirements.
1 Stall Door
Handles
Pg. 75, Item
C.1.
28 CFR
Part 36 App.
A - 4.13.9
Not Provided. U-Shaped handle shall be provided on front and back of compartment doors.
1 Stall Doors Pg. 75, Item
D.1.
CBC
1133B.2
Not Compliant. Provide 32" clear width from face of door at 90deg to opposite stop.
1 Grab Bars Pg. 76, Item
E.1.
2013 CBC
11B-604.5.2
Compliant grab bars Not Provided. Install proper grab bars at appropriate distance and measurements.
1 Side Grab Bar Pg. 76, Item
F.1.
Same as
Above
Not Compliant. Same as Above. 1
Rear Wall Grab
Bar
Pg. 76, Item
G.1.
Same as
Above
Not Compliant. Same as Above. 1
Grab Bar load Pg. 76, Item
H.1.
Same as
Above
Not Compliant. Same as Above. 1
Water Closet
location
Pg. 76, Item
I.1.
CBC
1115B.4.1
Not Compliant. The centerline of the water closet fixture shall need to be repositioned according to code.
1 Water Closet
Seat Cover
Pg. 77, Item
J.1.
CBC
1115B.4.1.4
Not Compliant 1
Sink Knee
Clearance
Pg. 77, Item
L.1.
CBC 11B603Curtain blocking knee clearance 1
Sink Mounted Pg. 77, Item
M.1.
Same as
Above
Not Compliant. Same as Above 1
Faucet Controls Pg. 78, Item
N.1.
CBC
1115B.4.3
Twist type. Install sink controls that do not require tight grasping, pinching or twisting.
1 Sink Mount
Center
Pg.79, Item
O.1.
CBC 11B606 /Not Provided. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition.
1 Exposed Pipes Pg. 79, Item
P.1.
CBC
1115B.4.3.4
Exposed pipes 1
Mirror Pg. 80, Item
Q. 1.
11B-603.3 53" / Greater than 40" to reflective surface 1 Restroom
Accessories
Pg. 81, Item
R.1.
CBC 11B603.5.(42" Soap Dispenser) ( 63" for Towel Dispenser) (60" Seat Covers). Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor.
1 Toilet dispenser Pg. 81, Item
S.1.
11B-604.7 Not Compliant. Toilet paper dispensers shall comply with 11B309.41 Coat Hooks Pg. 82, Item
T.1.
11B-604.8.3 67" to top of hook 1
Men’s Restroom: Section
15(B)
Cost Estimate: $15,000 Redesign and construction $16,987.50 Required
Clearance at
Water Closet
Pg. 84, Item
A.2.
11B-604.3
Clearance.
No accessible compartment provided. 1
Stall Door
Handles
Item B.2. Same as in
Women’s
1 Stall Doors Item C.2. Same as in
Women’s
1 Grab Bars Item D.2. Same as in
Women’s
1 Water Closet
Seat Cover
Pg. 85, Item
E.2.
Same as in
Women’s
Existing toilets in restroom are 15-1/2" AFF. Accessible toilets shall meet this code.
1 Faucet Controls Pg. 85, Item
F.2.
Same as in
Women’s
Twist type. Lever type or automatic required 1
Exposed Pipes Pg. 86, Item
G.2.
Same as in
Women’s
Exposed Pipes 1
14 | P a g e
62 City of Hermosa Beach
Transition Plan
Violations: Clark
Building
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
Accessible
Urinals
Pg. 86, Item
H.2.
CBC 11B605.219" to top of rim. 1
Urinal Lever Pg. 87, Item
I.2.
11B-605.4
Flush
Controls
48" AFF 1
Mirror Pg. 87, Item
J.2.
Same as in
Women’s
45" / Greater than 40" to reflective surface above finish floor. 1 Restroom
Accessories
Pg. 88, Item
K.2.
Same as in
Women’s
61" for Towel Dispenser. Provide at least one at 40" max to top of operable part.
1 Coat Hooks Pg. 88, Item
L.2.
Same as in
Women’s
Provide at least (1) hook and shelf at 48" max AFF 1
Shelves Pg. 89, Item
M.2.
Provide a shelf at 48" max AFF 1
Stage Areas: Section 16 Cost Estimate: $4000 for a ramp / $7000 for a lift. $4,530.00/ $7,927.50
Stage
Accessibility
Pg. 90, Item
A
CBC 11B206.2.4
No access to stage 3
15 | P a g e
63 City of Hermosa Beach
Transition Plan
c) Valley Park Building
Valley Park Building is located at 2521 Valley Dr.
Violations:
Valley Park
Building
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations:
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
date:
Miscellaneous
Doors
Section 2 Cost Estimate: $2,500 $2,831.25
Accessible door Pg. 8, Item
A.1
CBC
11B-404
Provide 32" clear width from face of door at 90deg to
opposite stop. Door 3' wide by 6'-8" shall be provided. 4 Door Closing
Speed
Pg. 8, Item
B.1
CBC 11B404.2.8.1Adjust or provide door closure so that from an opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door
4 Men’s Restroom
Door
Section
3(A)
Cost Estimate: $50 $56.63
Men’s Proper
Sign
Pg. 9-10
Item A.1
11B703.7.2.6Tactile Sign Not Provided 1
Women’s
Restroom
Door
Section
3(B)
Cost Estimate: $50 $56.63
Women’s
Proper Sign
Pg. 13-14,
Item A.2
11B703.7.2.6Tactile Sign Not Provided 1
Men’s Restroom Section
4(A)
Cost Estimate: $2,500 $2,831.25
Door Handles Pg. 16,
Item A.1
28 CFR
Part 36 App.
A - 4.13.9
Findings - Missing on exterior of door.
Provide door hardware mounted between 34" and 44"
above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching.
3 Water Closet Pg. 17,
Item B.1
CBC
1115B.4.1
Findings - 19-1/2" from side wall. The centerline of the water closet fixture shall be centered 17" to 18" from the side wall or partition
3 Exposed Pipes Pg. 17,
Item C.1
CBC
1115B.4.3.4
Findings - Exposed Pipe and hot water line. Provide
insulated wrapping around pipes under sink
1 Women’s
Restroom
Section
4(B)
Cost Estimate: $2,500 $2,831.25
Compartment
Door
Pg. 19,
Item A.2
ADA
404.2.8.2
Findings - Partition door does not close automatically 3 Water Closet Pg. 20,
Item B.2
CBC
1115B.4.1
Findings - 19" from side wall. The centerline of the water closet fixture shall be centered 17" to 18" from the side wall or partition.
3 Toilet Tissue
Dispenser
Pg. 21,
Item C.2
11B-309.4 Findings - Incorrect mounting location. Toilet paper dispensers shall be 7 inches
minimum and 9 inches maximum in front of the water
closet measured to the centerline of the dispenser
3 Exposed Pipes Pg. 22,
Item D.2
CBC
1115B.4.3.4
Findings - Partially Exposed. Provide insulated wrapping around pipes under sink.
1 Mirror Pg. 22,
Item E.2
CBC11B603.3Findings -Greater than 40" to reflective surface. Mirrors located above lavatories or countertops shall be installed with the bottom edge of
the reflecting surface 40 inches maximum above the finish floor or ground
3 Drinking
Fountains:
Section 5 Cost Estimate: $1,000 $1,132.50
Location Pg. 24,
Item A
CBC 11B-602 Findings - Wing walls or protection railing not provided. 4 Water Flow Pg. 25,
Item B
Findings - trickles out of spout for low. Approx. 2" for higher fountain. The water flow shall be 4" minimum high and shall be 5" maximum from the front of the fountain
including bumpers.
4 16 | P a g e
64 City of Hermosa Beach
Transition Plan
d) Kiwanis Shared Building Exterior Access and Parking
Kiwanis Club Building is located at 2515 Valley Dr.
Violations:
Kiwanis
Shared
Building
Exterior
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Exterior:
Site Arrival
Points:
Section 2 Cost Estimate: 10000 $11,325.00
Accessible
Route
Pg. 8,
Item A
CBC 11B206Findings - No accessible route provided from the city right-of-way.
Provide new ramp. 2
Overall
Parking:
Section 3 Cost Estimate: See Parking Spaces Section for cost estimates VanAccessible
Parking
Pg. 10,
Item B
CBC 11B208.2.4
Findings - Parking between buildings shall be Van accessible. 1 Tow Away
Sign
Pg. 11,
Item C
CBC 11B502.8Provide a new "Unauthorized Vehicle Tow Away" (R100B) sign 1 Parking Space
1:
Section
4(A)
Cost Estimate: 5000 $5,662.50
Accessible
Route
Pg. 13,
Item A.1
CBC 11B502.7Parking shall connect to the shortest possible accessible route to the accessible entrance/s. 1
ISA Symbol Pg. 14-
15, Item
C.1
CBC 11B502.6
Missing "Minimum FINE $250" sign 1
Cross Slopes Pg. 16,
Item D.1
CBC 11B502.4
Findings - 3.0% / 3.3% / 3.9%. Surfaces shall not exceed 1:48 (2%) 1
Accessible
Striping
Pg. 17-
19, Item
E.1
CBC
11B.502
Missing NO PARKING Stencil. Findings - 80" / Van Access Aisle less than 96" Minimum (8') measured centerline to centerline. (Minor
1 Parking Space
2:
Section
4(B)
Cost Estimate: 2500 $2,831.25
ISA Symbol Pg. 22,
Item A.2
CBC 11B502.6
Missing "Minimum FINE $250" sign 1
Cross Slopes Pg. 22-
23, Item
B.2
CBC 11B502.4Exceeds 1:48 (2%) in parking and/or access aisles (Findings -
3.3% slope in access aisle at accessible route join.)
1 Accessible
Striping
Pg. 23,
Item C.2
CBC
11B.502
Missing NO PARKING Stencil. Findings - 187" / Space and/or accessible parking less than 216" (18') in length. (Minor Violation) 1 Accessible
Routes
Exterior:
Section 5 Cost Estimate: To Be Determined
Walks Pg. 25-
27, Item
A
11B-403 Access from accessible parking to south building. Cross Slopes exceed 1:48 (2%) 48" minimum wide clear. (Findings- 2.8% /
4.2%) Slopes exceed 1:20 (5%) and shall be considered a "RAMP" (Landings and Hand railing Required). Findings - 12.2% slope in the direction of travel. / The slopes at the door landing was found to have extreme slopes in the direction of travel. A complete design for the entry door for the south building will need design to determine the most cost effective remediation. 2 Stairways: Section 6 Cost Estimate: $6000 - Railing and some removal and replacement $6,795.00 Treads and
Riser
Pg. 28,
Item A
11B-504.2 Findings - Risers not equal heights. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. 4 Railings Pg. 29-
31, Item
B
CBC 11B505.10.3Findings - Level extension not provided at several location on the railing for the three sets of stairs.
4 Stair Stripes Pg. 32,
Item C
11B504.4.1
Findings - Contrasting stripe not provided. Typical all 3 sets of exterior stairs. Exterior stairs shall have the upper approach and all treads marked by a stripe providing clear visual contrast. 4 17 | P a g e
65 City of Hermosa Beach
Transition Plan
e) Kiwanis South
Kiwanis Club South Building is located at 2515 Valley Dr.
Violations:
Kiwanis
South
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Exterior:
Entrance Doors: Section 2 Cost Estimate: $7000 $7,927.50 Accessible Door Pg. 8,
Item A
CBC 11B404Findings - 27-1/2" wide clear. / Typical findings at entry doors. Provide 32" clear width from face of door at 90deg to opposite stop.
1 Maneuvering
Space
Pg. 9-10,
Item D
CBC 11B40448" / Less than 60" from pull side of door. The floor or ground space within the required clearances shall be level and clear.
2 Smooth Surface Pg. 10,
Item E
CBC 11B404.2.10
Findings - Door hardware within 10" smooth area. 4
EXIT Sign Pg. 11-
12, Item
F
CBC 11B703
Findings - Not provided 2
Miscellaneous
Doors:
Section 3 Cost Estimate: $10,000 for doors accessed by the public and proposed $11,325.00 accessible egress.
Accessible Door Pg. 14,
Item A
CBC 11B404Findings - Existing storage doors have less than 32" min clear widths. These doors required to be accessible if
accessed by the public.
4 Door Hardware Pg. 14-
15, Item
B
CBC
11B-404-2-
7 Findings - Twist Type door knob, Several doors within the space have twist type door handles. Replace with level type door handles
2 Pull/Push Force Pg. 15-
16, Item
C
CBC 11B404.2.9North Facing egress door / Findings - Extremely difficult to activate panic bar.
1 Service Counters: Section 4 Cost Estimate: $3000 $3,397.50 Counter Top Pg. 18,
Item A
CBC 11B904.4Provide or modify sales or service counter to 28" minimum to 34" maximum height and 36" minimum long. Findings -
42" at pass thru services counter window. If these are used by the public it shall comply with this section.
4 Accessible Routes
Interior:
Section 5 Cost Estimate: Can move the appliances
Interior Path of
Travel
Pg. 18,
Item A
CBC 11B403.5.1Provide 36" minimum clear width in accessible path of travel. Kitchen access around center table / Findings - 25- 1/2" / 30" clear width
4 Reach Ranges for
Operable Parts:
Section 6 Cost Estimate: $500 $566.25
Reach Range Pg. 23-
24, Item
A
11B-308.2 Light switch and thermostat out of reach range. Does not meet "Safe Harbor" of 54" maximum.
2 Kitchens &
Kitchenettes:
Section 7 Cost Estimate: $250 $283.13
Lavatory Height Pg. 25,
Item A
11B-212.3 Findings - Provide (1) accessible sink in kitchen that meets section 11B-606. Modification to existing scullery sink not required.
3 Men’s Restroom
Door:
Section
8(A)
Cost Estimate: $3000 $3,397.50
Men’s Signs Pg. 27-
28, Item
A.1
11B-216.8 Tactile Sign Not Provided / Geometric sign not provided 1 Door Hardware Pg. 28,
Item B.1
CBC 11B404-2-7Findings - Twist Type door knob 1
Accessible Door
18 | P a g e
66 City of Hermosa Beach
Transition Plan
Violations:
Kiwanis
South
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Pg. 29,
Item C.1
CBC 11B404Provide 32" clear width from face of door at 90deg to opposite stop. Findings - 26" clear width
1 Maneuvering
Space
Pg. 31,
Item F.1
CBC 11B404
Findings - 56-1/2" (60" minimum required.) 1
Strike Side
Clearance
Pg. 32,
Item G.1
11B404.2.4.3Findings - 14-1/2" strike side clearance 1 Women’s
Restroom
Doors:
Section
8(B)
Cost Estimate: $3000 $3,397.50
Women’s Signs Pg. 35-
36, Item
A.2
11B-216.8 Tactile Sign Not Provided / Geometric sign not provided, Incorrect Mounting Location
1 Door Hardware Pg. 37,
Item B.2
CBC 11B404-2-7
Findings - Twist Type door knob 1
Accessible Door Pg. 38,
Item C.2
CBC 11B404
Findings - 27-3/4" clear width 1
Men’s Restroom: Section
9(A)
Cost Estimate: $15,000 $16.987.50
Accessible Route Pg. 41,
Item A.1
CBC 11B213
Non accessible door - See Men's Restroom Door section. 1 Wheelchair
Accommodation
Pg. 41,
Item B.1
CBC 11B603Provide 60" Turning Space in room. Findings - Not provided in restroom
1 Clearance at
Water Closet
Pg. 42-
43, Item
C.1
11B-604.3 Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall.
Findings - Not provided
1 Stall Doors Pg. 43,
Item D.1
CBC
1133B.2
Provide 32" clear width from face of door at 90deg to
opposite stop. Findings - There is no partition door, however the clear width is 23-1/2" wide.
1 Grab Bars Pg. 44,
Item E.1
CBC 11B604.5.2Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Findings - Not Provided or incorrect
1 Tissue Dispenser Pg. 44-
45, Item
H.1
11B-604.7 Shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the
dispenser. Findings - Incorrect Mounting Location
1 Clear Floor Space Pg. 45-
46, Item
I.1
11B-305.2 Findings - 44" / Not Provided at sink, Findings - 40" / Not Provided at urinal
1 Sink Mounting
From Side Wall to
Center
Pg. 47,
Item J.1
CBC 11B
606.6
Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink. Findings - 16" 1 Sink Mounting
from Finish Floor
and Rear Wall
Pg. 48-
49, Item
K.1
CBC 11B606
Mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance. Findings - 34- 1/2" to top of rim
1 Exposed Pipes Pg. 49,
Item L.1
CBC
1115B.4.3.
4 Provide insulated wrapping around pipes under sink.
Findings - Exposed
1 Mirror Height Pg. 50,
Item M.1
11B-603.3 Findings - 48-1/2" Greater than 40" to reflective surface above finish floor.
1 Restroom
Accessories
Pg. 51,
Item N.1
CBC 11B603.5.Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above
finish floor. Findings - ( 47" for Towel Dispenser) (No clear floor space and mounted too high Toilet seat covers)
1 19 | P a g e
67 City of Hermosa Beach
Transition Plan
Violations:
Kiwanis
South
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Accessible Urinal
Location
Pg. 52,
Item O.1
CBC 11B605.2Rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided.
Findings - 24-1/2" to lip of urinal
1 Lever on
Accessible Urinal
Pg. 52,
Item P.1
11B-605.4 Findings - 47" to top of lever 1
Women’s
Restroom:
Section
9(B)
Cost Estimate: 15000 $16.987.50
Accessible Route Pg. 55,
Item A.2
CBC 11B213
Non accessible door 1
Path of Travel Pg. 56,
Item B.2
CBC 11B603
Not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the
circulation path. Findings - 79-3/4" partition clearance 1 Clearance at
Water Closet
Pg. 57-
58, Item
C.2
11B-604.3 Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall.
Findings - Not provided
1 Grab Bars Pg. 58,
Item D.2
CBC 11B604.5.2Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Findings - Not Provided or incorrect
1 Tissue Dispenser Pg. 59,
Item G.2
11B-604.7 Shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the
dispenser. Findings - Incorrect Mounting Location
1 Clear Floor Space Pg. 60,
Item H.2
11B-305.2 Findings - 29-1/2" clear width. 36" minimum clear with side walls greater than 24" from the rear wall.
1 Sink Mounting
From Side Wall to
Center
Pg. 61-
62, Item
I.2
CBC 11B
606.6
Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink. Findings - 14" to center
1 Sink Mounting
from Finish Floor
and Rear Wall
Pg. 63,
Item J.2
CBC 11B606Mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance… Findings - Bottom underside of sink encroaches on the knee
clearance.
1 Exposed Pipes Pg. 64,
Item K.2
CBC
1115B.4.3.
4 Provide insulated wrapping around pipes under sink.
Findings - Exposed
1 Mirror Height Pg. 64,
Item L.2
11B-603.3 Findings - 44-1/2" / Greater than 40" to reflective surface. 1 Restroom
Accessories
Pg. 65,
Item M.2
CBC 11B603.5.
Relocate (or provide same) restroom accessories to a
height of 40" maximum to highest operable parts above
finish floor. Findings - (59-1/2" Paper Towels)
1 Coat Hooks Pg. 66,
Item N.2
11B604.8.3
Shelves shall be located 40 inches minimum and 48 inches maximum above the finish floor. Findings - 65"
1 Light
Switch/Outlets
Pg. 66,
Item O.2
11B308.1.1Findings - 58" / Does not meet "Safe Harbor" at 54" max 1 Group A
Occupancies:
Section
10 Cost Estimate: $1000 - $5000 $1,132.50-$5,662.50
AssistiveListening System
Pg. 67,
Item A
11B-219.2 Required Systems. An Assistive Listening System shall be provided in assembly areas, including conference and
meeting rooms. Findings - Not Provided
2 20 | P a g e
68 City of Hermosa Beach
Transition Plan
f) Kiwanis North
Kiwanis Club North Building is located at 2515 Valley Dr.
Violations: Kiwanis
North
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Exterior:
Ramps: Section 2 Cost Estimate: $15,000 $16.987.50
Slope of Ramp Pg. 7, Item
A
CBC 11B405Slopes on ramp shall not exceed 1:12 (8.33%) and maximum 1:48 (2%) cross slope. Findings - 8% at top near door. 2 Level Landing Pg. 8, Item
B
CBC 11B405.7
Findings - No door landing and no top ramp landings. Ramp continues to door threshold. Note: Design of a ramp and stairs are required for this area.
2 Pedestrian Ramp Pg. 9, Item
C
CBC 11B405.8Ramps shall provide hand railing on each side of ramp. Findings - Not Provided 2
Entrance Doors: Section 3 Cost Estimate: $5,000 $5,662.50 Door Hardware Pg. 11-12,
Item B
CBC 11B404-2-7Findings - Twist Type door knob- Door to Activity Area, Door to Meeting Room/Office Area 1
Maneuvering Space Pg. 13-14,
Item E
CBC 11B40448" / Less than 60" from pull side of door. The floor or ground space within the required clearances shall be level and clear. 3 Threshold Pg. 14-15,
Item F 404.2.5
Entry Doors to Activity Area / Findings - 1-1/2" to top of threshold; Entry Door to Meeting/Office Area / Findings - 2" to top of threshold.
1 Smooth Surface Pg. 16, Item
G
CBC 11B404.2.10Entry Doors to Activity Area / Findings - door stop in 10" smooth portion of door on the push side. 3
EXIT Sign Pg. 17-18,
Item H
CBC 11B703 Findings - Not provided 2
Miscellaneous Doors: Section 4 Cost Estimate: $4,000 $4,530.00 Accessible Door Pg. 19, Item
A
CBC 11B404
Findings - 29" clear width / This Door may not be required to be accessible. Door to kitchen accessed through activity area / Findings - 28" clear width
3 Door Hardware Pg. 21-22,
Item B
CBC11B404-2-7
Findings - Twist Type door knob. Note: Doors to be used by the public shall be accessible. Shall be replaced with lever type handles.
3 Strike Side
Clearance
Pg. 23, Item
C
11B404.2.4.3Kitchen door accessed through activity area - Findings - 9" strike side clearance 3
Reach Ranges for
Operable Parts: Section 5 Cost Estimate: $1,500 $1,698.75 Reach Range Pg. 25-27,
Item A 11B-308.2
Fire Extinguishers are required to be at 48" to handle for current code. It is recommended to lower top of operable part to 48" above finish floor. Outlet out of reach range. Thermostat out of reach range
3 Kitchens &
Kitchenettes:
Section 6 Cost Estimate: $4,000 $4,530.00
Lavatory Height Pg. 30, Item
A
11B-212.3
Findings - No accessible sink provided. Install additional accessible sink if possible. If not, this sink shall meet current code requirements.
3 Ranges or Cooktops
control locations
Pg. 25, Item
C
11B-804.6.4 Findings - Controls require reaching over burners. 3 Men’s Restroom
Door:
Section 7(A) Cost Estimate: $2,500 $2,831.25
Men’s Signs Pg. 33-34,
Item A.1 11B-216.8 Tactile Sign Not Provided / Geometric sign not provided 1 Door Hardware Pg. 34, Item
B.1
CBC11B404-2-7
Findings - Twist Type door knob 1
Accessible Door Pg. 35, Item
C.1
CBC 11B404Provide 32" clear width from face of door at 90deg to opposite stop. Findings - 27" clear width 1
Maneuvering Space Pg. 31, Item
D.1
CBC 11B404Findings - 37" on pull side / Less than 60" on pull side of door. / Less than 18" on strike side clearances on the pull side of door. 1 Women’s Restroom
Doors:
Section 7(B) Cost Estimate: $2,500 $2,831.25
Women’s Signs Pg. 38-39,
Item A.2 11B-216.8 Tactile Sign Not Provided / Geometric sign not provided 1 Door Hardware Pg. 39, Item
B.2
CBC 11B404-2-7
Findings - Twist Type door knob 1
21 | P a g e
69 City of Hermosa Beach
Transition Plan
Violations: Kiwanis
North
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Accessible Door Pg. 41, Item
C.2
CBC 11B404Findings - 27" clear width, Interior door passage is less than 32" minimum clear width. / Findings - 30" 1
Maneuvering Space Pg. 42, Item
F.2
CBC 11B404 Findings - 34" on pull side of door 1
Men’s Restroom: Section 8(A) Cost Estimate: $15,000 $16,987.50 Accessible Route Pg. 44, Item
A.1
CBC 11B213 Findings - See Restroom Door section 1
Wheelchair
Accommodation
Pg. 45, Item
B.1
CBC 11B603 Findings - Not Provided - Very small restroom 1 Clearance at Water
Closet
Pg. 47, Item
C.1 11B-604.3
Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. Findings - Not provided
1 Grab Bars Pg. 47, Item
D.1
CBC 11B604.5.2Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Findings - Not Provided 1
Sink Knee Clearance Pg. 48-49,
Item H.1
CBC 11B603Findings - Pedestal sinks are not accessible - knee clearance not provided 1
Mirror Height Pg. 50, Item
J.1 11B-603.3 Findings - 48-1/2" Greater than 40" to reflective surface above finish floor. 1 Restroom
Accessories
Pg. 51, Item
K.1
CBC 11B603.5.
Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor.
Findings - (48" for Towel Dispenser)
1 Accessible Urinal
Location
Pg. 52, Item
L.1
CBC 11B605.2
Rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided. Findings - 26-1/2" to rim
1 Lever on Accessible
Urinal
Pg. 52, Item
M.1 11B-605.4 Findings - 51" to top of lever 1
Women’s Restroom: Section 8(B) Cost Estimate: $15,000 $16,987.50 Accessible Route Pg. 54, Item
A.2
CBC 11B213 Findings - See Restroom Doors section. 1
Path of Travel Pg. 55, Item
B.2
CBC 11B603
Not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path.
Overhead obstruction / Findings - 77-1/2"
1 Wheelchair
Turnaround
Pg. 56, Item
C.2
CBC 11B603
Findings - Very small restroom
1 Clearance at Water
Closet
Pg. 56-58,
Item D.2 11B-604.3
Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. Findings - Not provided
1 Grab Bars Pg. 59, Item
E.2
CBC 11B604.5.2Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Findings - Not Provided or incorrect 1
Sink Knee Clearance Pg. 60, Item
I.1
CBC 11B603Findings - Pedestal sinks are not accessible - knee clearance not provided 1
Faucet Controls and
Operable Parts
Pg. 61, Item
J.2
CBC 11B309.4
Operable Parts shall not require tight grasping, pinching or twisting. Control shall be operable with one hand and shall not require tight grasping, pinching or twisting. Findings - twist type faucet controls.
1 Mirror Height Pg. 61, Item
K.2 11B-603.3 Findings - 48" / Greater than 40" to reflective surface. 1 Restroom
Accessories
Pg. 62, Item
L.2
CBC 11B603.5.
Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor.
Findings - (47" for Towel Dispenser)
1 Group A
Occupancies:
Section 9 Cost Estimate: $1000 - $5000 $1,132.50-$5,662.50 Assistive-Listening
System
Pg. 63, Item
A
11B-219.2
Required Systems. An Assistive Listening System shall be provided in assembly areas, including conference and meeting rooms. Findings - Not Provided 2
22 | P a g e
70 City of Hermosa Beach
Transition Plan
g) Fire Department
Fire Department is located at 540 Pier Ave
Violation
s: Fire
Depart
ment
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations:
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Accessible
Routes
Exterior:
Section 3 Cost Estimate: Unknown & unclear if feasible to do so. $566.25 $500 for proposed solution
Path Of Travel Pg. 8,
Item A 11B-307.2
Emergency Fire Alarm mechanism violates obstacle
requirements. Moving it may violate other requirements set forth in City Codes. Findings - Greater than 4" from Wall / More than 27" from floor Proposed solution is to add something under the unit to 27" minimum from the concrete surface. 2 Stairways: Section 4 Cost Estimate: Not required - If the City choose to alter these stairs to meet $16,987.50-22,650.00 accessibility requirements, the estimated cost would be around $15000-20000 Risers
Pg. 11-
12, Item
A
11B-504.2
Risers shall be 4 inches high minimum and 7 inches high maximum. Findings - 7-3/4" riser heights Note: No Action required
4 Stairs Shall Have
Closed Risers
Pg. 13,
Item B 11B-504.3
Open risers are not permitted. EXCEPTIONS: 1. On exterior stairways, an opening of not more than 1/2 inch may be
permitted between the base of the riser and the tread. Findings - Open Risers. Note: No action required.
4 Hand Railings Pg. 13,
Item C 11B-505.2
Handrails shall be provided on both sides of stairs and ramps.
Findings - No Hand railing provided Note: Not required unless modified or altered.
4 Stairs Have Stripe
on Treads
Pg. 14,
Item D
11B504.4.1Findings - Not Provided Note: Not required unless altered or modified. 4
Entrance Doors: Section 5 Cost Estimate: $2,500 $2,831.25 Pull/Push Force
less than 5lbs
Pg. 16,
Item B
CBC 11B404.2.9 Findings - 15lbs of pressure 2
Maneuvering
Space for Forward
Approach
Pg. 17-
18, Item
C
CBC 11B404Exterior door landings exceed 2% max in all directions.
Findings - 4.5% 3
Miscellaneous Doors: Section 6 Cost Estimate: $1500 Note: No Action Required. Information only $1,698.75 Door Hardware
Pg. 19-
20, Item
A
CBC 11B404-2-7
Findings - Twist Type door knob 4
Pull/Push Force
less than 5lbs
Pg. 20,
Item B
CBC 11B404.2.9Door from garage to living quarters and office area. 8lbs. of pressure
4 Strike Side
Clearance
Pg. 21-
22, Item
D
11B404.2.4.3
Door from garage to living quarters and office area. Findings - 4" strike side clearance on pull side of door. 4
Threshold Pg. 23,
Item E
CBC 11B404.2.5
Findings - Exterior and/or interior door maneuvering space is greater than 1/2 in. maximum for top of threshold to
maneuvering space. Sliding door are included. Note: Not required to be accessible unless modified or altered
.
4 Service Counters: Section 7 Cost Estimate: $500 to provide a counter at 34" maximum above finish floor. $566.25 Counter Top Pg. 25,
Item A
CBC 11B904.4
Findings - 38-1/2" to top of counter. If the public does any kind of transaction including information(s) exchange at this counter, then it shall comply.
3 Accessible
Routes
Interior:
Section 8 Cost Estimate: Move Furniture
Interior Path
Pg. 26-
27, Item
A
CBC 11B403.5.1
Areas of accessible routes throughout the facility for
employees shall have a minimum width of 36" Findings -
Locations less than 36" minimum clear width.
3 Unisex Restroom
Door:
Section
11 Cost Estimate: $250 Note: No Action Required $283.13 Unisex Signs
Pg. 33-
34, Item
A
11B-216.8 Findings - Geometric sign on door not provided Findings - Missing Tactile Sign on wall Note: No Action Required 4 23 | P a g e 71
City of Hermosa Beach
Transition Plan
Violation
s: Fire
Depart
ment
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Recommendations:
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date:
Door Closing no
Faster than 5
seconds
Pg. 34,
Item B
CBC
11B404.2.8.1
Findings - 3 Seconds 90-12 4
Pull/Push Force
5lbs or Less
Pg. 35,
Item C
CBC 11B404.2.9 Findings - 15lbs of pressure 4
Strike Side
Clearance
Pg. 35,
Item E 404.2.4 Findings - 13" strike side clearance (18" min required) 4 Unisex Restroom: Section
12 Cost Estimate: $3000 Note: No Action Required. Estimated cost are for $3,397.50 information only if alterations or modifications are performed.
Grab Bars Pg. 37,
Item A
CBC
11B604.5.2
Findings - Not Provided Note: No Action Required 4
Water Closet
Location above
Finish Floor
Pg. 38,
Item B
CBC
1115B.4.1
.
4 Install water closet with a seat height of 17" - 19" above finish floor. Findings - 16" to top of seat 4
Sink Location Pg. 39,
Item C
CBC
11B606.3
Mounted with the rim or counter edge no higher than 34" above finish floor. Findings - 37" to top of sink rim. Note: No Action Required
4 Exposed Pipes Pg. 40,
Item D
CBC
1115B.4.3
.
4 Provide insulated wrapping around pipes under sink. Findings - Exposed Note: No Action Required 4
Clear Floor Space
around Accessible
Urinal
Pg. 41,
Item E
CBC
11B- 305
Findings - 40" (48" minimum required) Note: No Action
Required 4
Accessible Urinal
Location
Pg. 42,
Item F
CBC
11B605.2
Where one or more wall-hung urinals are provided, at least one with an elongated rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided. Findings - 25" to rim. Note: No Action Required 4 Accessible Urinal
Lever
Pg. 42,
Item G 11B-605.4 Mounted at a maximum height of 44 inches above the finish floor. Findings - 46" to lever. Note: No Action Required 4 Mirror Location Pg. 42,
Item H
CBC11B603.3Findings - 53-1/2" / Greater than 40" to reflective surface. No Action Required 4
Restroom
Accessories
Pg. ,
Item I
CBC
11B603.5.
Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor.
Findings - (62" for Towel Dispenser) (61" Seat Covers) Note:
No Action Required.
4 24 | P a g e
72 City of Hermosa Beach
Transition Plan
h) Police Department
The Police is located at 540 Pier Ave
Violations:
Police
Departme
nt
Pg. Ref.,
Item
Number
Code
Reference
Comments:
Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Recommendations: Date:
Interior:
Entrance Doors: Section 2 Cost Estimate: $100 $113.25
Door Closing
Speed
Pg. 7, Item
A
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12 2
Smooth Surface
on Bottom of Door
Pg. 8, Item
C
CBC 11B404.2.10 Findings - Door Stop in 10" smooth area 3 EXIT Sign Pg. 9, Item
D
CBC 11B703Findings - Not provided 2
Miscellaneous
Doors:
Section 3 Cost Estimate: $2500 (to building a landing and ramp to landing at the $2,831.25 detainee loading area.)
Threshold Pg. 10-11,
Item A
CBC
11B404.
2.5 Entry door at detainee unloading area. Findings - 6" step into the building at the threshold. Pass-through door from detainee unloading area. Findings - 5/8" vertical change in elevation to the top of the threshold. (1/4" vertical and 1/4" beveled max
required)
4 Service Counters: Section 4 Cost Estimate: $2,500 $2,831.25 Counter Top Pg. 12,
Item A CBC 11B904.4
Information Service Counter shall be accessible.
Findings - 36" to top of counter (Not an ADA Violation, Violation with CA Building code requirements.) The
pass through window is greater than 36" which is a
violation. Provide accessible
counter.
3 Clear Floor or
Ground Space
Pg. 13,
Item B CBC1118B.
4 Findings - No Clear floor space provided. 2
Dining and Work
Surfaces: Section 5 Cost Estimate: $4,000 $4,530.00
Detention
Facilities
Pg. 14,
Item A 11B-232.5
This area is used for the public to discuss matters with an officer. The public side shall meet ADA code
requirements. The officer side of the security glass is considered an employee work station and is required to
be accessible if altered or modified. The violation is
limited to the full depth of the knee clearance of
19" minimum.
3 Men’s Restroom
Door:
Section
6(A) Cost Estimate: $3,000 $3,397.50
Men’s Signs Pg. 18-19,
Item A.1 11B-216.8 Tactile Sign Not Provided 1
Accessible Door Pg. 19,
Item B.1 CBC 11B404
Provide 32" clear width from face of door at 90deg to
opposite stop. Findings - 28-1/2" clear width 1
5 Seconds 90 to
12deg
Pg. 20,
Item C.1
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12 1
Pull/Push Force
Less Than 5lbs
Pg. 20,
Item D.1
CBC
11B404.
2.9 Findings - 8lbs 1
Strike Side
Clearance
Pg. 21-22,
Item E.1 11B404.2.4.3
Findings - 2" strike side clearance on push side of door. (12" required when both latch and closure are provided) This may be "Technically Infeasible" to provide strict and full compliance for doors. This may need to be verified by an engineer to determine the feasibility and if structural wall would need to be
altered to meet accessibility requirements.
1 Women’s
Restroom
Doors:
Section
6(B) Cost Estimate: $3,000 $3,397.50
Women’s Signs Pg. 24-25,
Item A.2 11B-216.8 Tactile Sign Not Provided 1
25 | P a g e
73 City of Hermosa Beach
Transition Plan
Violations:
Police
Departm
ent
Pg.
Ref.,
Item
Number
Code
Reference
Comments:
Priority
(1-4)
UPDATED
ESTIMATED COST Implementation
Recommendations: Date:
Accessible Door Pg. 25,
Item B.2 CBC 11B-404 Provide 32" clear width from face of door at 90deg to opposite stop. Findings - 28-3/4" clear width 1
5 Seconds 90 to
12deg
Pg. 26,
Item C.2
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12deg 1
Pull/Push Force
Less Than 5lbs
Pg. 26,
Item D.2
CBC 11B404.2.9 Findings - 9lbs 1
Strike Side
Clearance
Pg., Item
E.2 11B-404.2.4.3
Findings - 4" strike side clearance on push side of
door. (12" required when both latch and closure are
provided). This may be "Technically Infeasible" to
provide strict and full compliance for doors. This may
need to be verified by an engineer to determine the
feasibility and if structural wall would need to be
altered to meet accessibility requirements.
1 Men’s Restroom : Section
7(A) Cost Estimate: $15,000 $16,987.50
Public Toilet
Located on an
Accessible Route
Pg. 30,
Item A.1 CBC 11B-213 Findings - See Restroom Doors section for violations found. 1
Bathroom be
Large Enough to
Accommodate a
Wheelchair
Pg. 30,
Item B.1 CBC 11B-603
There shall be sufficient space in the toilet room for a wheel chair measuring 30" wide by 48" long to enter
the room and permit the door to close. Findings - 59-
1/2" clear width in restroom. 60" minimum required
(Minor Violation)
1 Grab Bars Pg. 32,
Item D.1
CBC11B604.5.2Findings - Toilet plumbing is blocking access to the grab bar. 2
Water Closet Pg. 33,
Item E.1 CBC1115B.4.1
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or partition.
Findings - 18-3/4" from side wall
2 Flushing Lever Pg. 34,
Item F.1 CBC11B-604.6
Control shall be on the wide side of the toilet area
and mounted no more than 44" above the finish floor.
Findings- short side of stall
1 Sinks Mount from
Side Wall
Pg. 34,
Item G.1 CBC 11B 606.6
Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink.
Findings - 14-1/2" from side wall. (Not a violation of
the ADA Standards for accessible design.)
2 Sink Mount from
Finish Floor
Pg. 35,
Item H.1 CBC 11B-606 Mounted with the rim or counter edge no higher than34" above finish floor… Findings - 35" to top of rim 1 Exposed Pipes Pg. 36,
Item I.1 CBC1115B.4.3.
4 Provide insulated wrapping around pipes under sink.
Findings - Exposed drain pipe 1
Mirror Location Pg. 36,
Item J.1 11B-603.3 Findings - 41" / Greater than 40" to reflective surface. 2 Accessories Pg. 37,
Item K.1 CBC 11B-603.5
Relocate (or provide same) restroom accessories to
a height of 40" maximum to highest operable parts
above finish floor. Findings - (49" Soap Dispenser)
1 Women’s
Restroom:
Section
7(B) Cost Estimate: $5,000 $5,662.50
Public Toilet
Located on an
Accessible Route
Pg. 39,
Item A.2 CBC 11B-213 Findings - See Restroom Doors section for violations found. 1 Grab Bars Pg. 41,
Item D.2
CBC
11B604.5.2
Findings - Toilet plumbing is blocking access to the
grab bar. 2
Water Closet Pg. 42,
Item E.2 CBC 1115B.4.1
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or partition.
Findings - 18-3/4" from side wall
2 Sinks Mount from
Side Wall
Pg. 42,
Item F.2 CBC 11B 606.6
Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink.
Findings - 16" from side wall. (Not a violation of the
ADA Standards for accessible design.)
1 Sink Mount from
Finish Floor
Pg. 43,
Item G.2 CBC 11B-606 Mounted with the rim or counter edge no higher than34" above finish floor. Findings - 35" to top of rim 1 Mirror Location Pg. 44,
Item H.2 11B-603.3 Findings - 41-1/2 / Greater than 40" to reflective surface. 2
26 | P a g e
74 City of Hermosa Beach
Transition Plan
Violations:
Police
Departm
ent
Pg.
Ref.,
Item
Number
Code
Reference
Comments:
Priorit
y (1-
4)
UPDATED
ESTIMATED
COST
Implementatio
Recommendations: n Date:
Accessories Pg. 45,
Item I.2 CBC 11B603.5
Relocate (or provide same) restroom accessories to a
height of 40" maximum to highest operable parts
above finish floor. Findings - (50" Seat Covers)
1 Coat Hooks Pg. 46,
Item J.2 11B-604.8.3 Findings - 67" to top of hook. Provide at least one hook at 48" max above finish floor. 2
Holding Cells:
Toilets
Section 8 Cost Estimate: $5000 (to provide new fixtures and grab bars) $5,662.50 Common Area
Public Toilet
Located on
Accessible Route
Pg. 47,
Item A CBC 11B-213
Provide an accessible route to accessible toilet
facilities. Findings - Door widths to holding cells are less than 32" minimum clear width requirements.
2 Grab Bars Pg. 48,
Item B
CBC
11B604.5.2
Findings - Not Provided throughout facility. 2
Water Closet
From Side Wall
Pg. 49,
Item C CBC 1115B.4.1
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or partition.
Findings - 14-1/2" from side wall
2 Water Closet Seat
Cover
Pg. 49,
Item D
CBC
1115B.4.
1.4 Install water closet with a seat height of 17" - 19" above finish floor. Findings - 15" 2
Sink Knee
Clearance
Pg. 50,
Item E CBC 11B-603 Findings - Not Provided 2
Holding Cells:
Showers
Section 9 Cost Estimate: $3,500 $3,963.75
Roll-in Shower
Width
Pg. 54-56,
Item A 11B-806.2.4 Findings - Accessible Roll-in shower not provided.Typical Findings - Showers not accessible. 2 Grab Bars Pg. 57,
Item B 11B-608.3.2 Findings - Not provided 2
Shower Spraying
Unit
Pg. 57,
Item C 11B-608.6
A shower spray unit with a hose 59 inches long
minimum that can be used both as a fixed-position
shower head and as a hand-held shower shall be
provided. Findings - Not provided
2 Shower Seats
Provided
Pg. 58-59,
Item D 11B-610.3 Findings - Not Provided 2
Controls Pg. 60,
Item E 11B-608.5 Findings - Not Positioned and incorrect controls 2 Drinking Fountains: Section 10 Cost Estimate: $3,000 $3,397.50 Knee and Toe
Clearance
Pg. 62-63,
Item A CBC 11B-603 Findings - No knee clearance provided 4 Alcoves Projection
into Paths of
Travel
Pg. 64,
Item B CBC 11B-602
Drinking fountains shall be located in an alcove,
between wing walls, or positioned not to project into
the accessible route more than 4". Findings - No
alcove or protection provided
4 Detention Facilities
and
Correctional
Facilities:
Section 11 Cost Estimate: $20,000 $22,650.00
Cells with Mobility
Features
Pg. 65-66,
Item A 11B-232.2.1 Findings - Full mobility features not provided. Toilet and Bathing Facilities Mobility Features not provided. 2 Special Holding
Cells and Housing
Cells
Pg. 67,
Item B 11B-232.3
Where special holding cells or special housing cells are provided, at least one cell serving each purpose
shall provide mobility features Findings - No Mobility
features provided
2 27 | P a g e
75 City of Hermosa Beach
Transition Plan
i) City Hall
City Hall is located at 1315 Valley Dr.
Violations: City Hall
Pg.
Ref.,
Item
Number
Code Reference
Comments: Prio
rity
(1-
4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Exterior:
Entrance Doors (East
Side):
Section
2(A) Cost Estimate: $100 $113.25
Smooth Surface 10”
at Bottom of
Door
Item
C.1, Pg.
8 CBC
11B404.2.10
Provide a 10" smooth panel on the push side of door
or gate. Findings - Door stop in 10" smooth area 3
Entrance Doors
(West Side):
Sectio
n 2(B) Cost Estimate: $100 $113.25
Door Closing
Speed
Item
A.2, Pg.
9 CBC
11B404.2.8.1
Adjust or provide door closure so that from an
opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch,
measured from the leading edge of the door. Findings
- 3 Seconds 90-12 on right door leaf / 4 Seconds 90-
12 on left door leaf
2 Pull/Push Force Item
B.2, Pg.
10 CBC
11B404.2.9
Modify door pull/push force to maximum of 5lbs of
pressure 30" from the hinge or the door hardware
whichever is furthest from the hinge. Findings - 9lbs
Right door leaf / 10lbs Left door leaf.
2 Smooth Surface
10” at Bottom of
Door
Item
C.2, Pg.
10 CBC
11B404.2.10
Findings - Door stop in 10" smooth area on push side
of door. 3
Finance / City
Treasurer Entry Door:
Section
3(A) Cost Estimate: $100 $113.25
Pull/Push Force Item
B.1, Pg.
11 CBC
11B404.2.9
Findings - 10lbs 2
Smooth Surface
10” at Bottom of
Door
Item
C.1, Pg.
12 CBC
11B404.2.10
Findings - Door stop in 10" smooth area 3
City Manager / City
Clerk Entry Door:
Section
3(B) Cost Estimate: $100 $113.25
Pull/Push Force Item
A.2, Pg.
13 CBC
11B404.2.9
Findings - 8lbs 2
Smooth Surface
10” at Bottom of
Door
Item
B.2, Pg.
14 CBC
11B404.2.10
Findings - door stop in 10" smooth area 3
Conference Room 2
Entry Door:
Section
3(C) Cost Estimate: $100 $113.25
Door Hardware Item
A.3, Pg.
15 2013 CBC 11B404-2-7
Provide door hardware mounted between 34" and 44"
above finish floor. Hardware shall be easy to grasp
with one hand and shall not be required to twist with
the wrist, grasp tightly or does not require tight
pinching. Findings - Twist Type door knob
1 Staff Only / Public Use
Entry Door:
Section
3(D) Cost Estimate: $100 $113.25
Door Hardware Item
A.4, Pg.
17 2013 CBC 11B404-2-7
Findings - Twist Type door knob 1
Engineering Entry
Door:
Section
3(E) Cost Estimate: $100 $113.25
Exits Signs Item
A.5, Pg.
18 CBC 11B-703 Provide tactile EXIT sign at exit doors in accordance with CBC 11B-703 Signs. Findings - Not provided 3
Smooth Surface 10”
at Bottom of
Door
Item
B.5, Pg.
19 CBC
11B404.2.10
Findings - Door stop in 10" smooth area on push side
of door. 3
Community
Development
Entry Door:
Sectio
n 3(F) Cost Estimate: $100 $113.25
28 | P a g e 76
City of Hermosa Beach
Transition Plan
Violations: City
Hall
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Door Closing
Speed
Item A.6,
Pg. 20
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12 2
Pull/Push Force Item B.6,
Pg. 20
CBC 11B404.2.9 Findings - 10lbs 2
Smooth Surface
10” at Bottom of
Door
Item C.6,
Pg. 21
CBC 11B404.2.10Findings - Door stop in 10" smooth area on push side of door. 3
Conference Room
1 Door:
Section
3(G) Cost Estimate: $100 $113.25
Door Closing
Speed
Item A.7,
Pg. 22
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12 2
Pull/Push Force Item B.7,
Pg. 22
CBC 11B404.2.9 Findings - 10lbs. 2
Smooth Surface
10” at Bottom of
Door
Item C.7,
Pg. 23
CBC 11B404.2.10 Findings - Door stop on push side. 3
Doors
Leading to
Chambers:
Section
3(H) Cost Estimate: $100 $113.25
Pull/Push Force Item A.8,
Pg. 23-25
CBC 11B404.2.9Findings - 9lbs / 8lbs typical all doors. Findings - 10lbs typical 2
Smooth Surface
10” at Bottom of
Door
Item B.8,
Pg. 26
CBC 11B404.2.10 Findings - Door stop on push side of door. 3 Misc. Doors
– Exit
Signs:
Section 3(I) Cost Estimate: $500 - For all doors and passage ways $566.25 with illuminated EXIT signs.
Exits Signs Item A.9,
Pg. 27-29 CBC 11B-703
Findings - Not provided / Typical Findings. All
illuminated EXITs shall have Tactile EXIT signs
throughout the facility.
3 City Manager /
Clerk
Service Counter:
Section
4(A) Cost Estimate: $2,000 $2,265.00
Counter Top
Height
Item A.1,
Pg. 31 CBC 11B-904.4
Provide or modify sales or service counter to 28"
minimum to 34" maximum height and 36" minimum
long. Findings - 40-1/4" above finish floor to top of
counter
2 Engineering
Service
Counter:
Section
4(B) Cost Estimate: $2,500 $2,831.25
Counter Top
Height
Item A.2,
Pg. 33 CBC 11B-904.4 Findings - 40-1/2" to top of counter. 2 Interior:
Accessible Routes
Interior: Section 5 Cost Estimate: No Cost
Interior Path of
Travel
Item A, Pg.
34-35
CBC 11B403.5.1
Provide 36" minimum clear width in accessible path
of travel. Staff Only Room - This room is used for
several different types of services and shall provide a turning space and 36" minimum accessible route
throughout. Path of travel through the employee area
is required to be provided. Provide 36" minimum clear
for an accessible route.
2 Men’s
Restroom Door
Lower Level:
Section
6(A) Cost Estimate: $150 $169.88
Proper Signs Item A.1,
Pg. 37 11B-216.8 Findings - Incorrect Mounting Location Incorrect sign 1 Door Closing
Speed
Item B.1,
Pg. 37
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12 1
Pull/Push Force Item C.1,
Pg. 38
CBC 11B404.2.9 Findings - 14lbs 1
Strike Side
Clearance
Item D.1,
Pg. 39-40 11B-404.2.4.3
Maneuvering clearances for forward approach shall
be provided when any obstruction within 18 inches of
the latch side of an interior doorway, or within 24
inches of the latch side of an exterior doorway,
projects more than 8 inches beyond the face of the
door, measured perpendicular to the face of the door
or gate. Findings - 15-1/2" strike side clearance on
2 29 | P a g e
77 City of Hermosa Beach
Transition Plan
Violations: City Hall
Pg.
Ref.,
Item
Number
Code Reference
Comments: Priorit
y (1-
4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
pull side of door. Move urinal partition wall.
Maintain 30" minimum clearance for urinal.
Women’s Restroom
Door Lower Level:
Section
6(B) Cost Estimate: $100 $113.25
Proper Signs Item A.2,
Pg. 41 11B-216.8 Findings - Incorrect mounting location / Incorrect sign 1 Door Closing
Speed
Item B.2,
Pg. 42
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12 1
Pull/Push Force Item C.2,
Pg. 42
CBC 11B404.2.9 Findings - 10lbs 1
Men’s Restroom Door
Upper Level:
Section
6(C) Cost Estimate: $3000 - To raise exterior level to 1/2" max $3,397.50 below top of threshold.
Proper Signs Item A.3,
Pg. 44 11B-216.8 Incorrect Tactile Wall Sign 1
Door Closing
Speed
Item B.3,
Pg. 44
CBC 11B404.2.8.1 Findings - 1 Seconds 90-12 1
Pull/Push Force Item C.3,
Pg. 44
CBC 11B404.2.9 Findings - 8lbs 1
Threshold Item D.3,
Pg. 45
CBC 11B404.2.5
Provide or modify door threshold or raise
maneuvering space so that the floor or landing shall
not be more than 1/2" lower than the top of the
threshold of the doorway, changes in level between
1/4" and 1/2" shall be beveled with a slope no
greater
than 1:2. Findings - 1" change in elevation to top
of threshold
2 Women’s Restroom
Door Upper Level:
Section
6(D) Cost Estimate: $150 $169.88
Proper Signs Item A.4,
Pg. 46 11B-216.8 Findings - Missing Tactile wall sign 1 Door Closing
Speed
Item B.4,
Pg. 47
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12 1
Pull/Push Force Item C.4,
Pg. 47
CBC 11B404.2.9 Findings - 8lbs 1
Men’s Restroom Lower
Level:
Section
7(A) Cost Estimate: $1,250 $1,415.63
Flushing Lever Item A.1,
Pg. 48 CBC 11B-604.6 Install toilet with the control on the open side of the water closet. Findings- Short side of stall. 2 Faucet Controls Item B.1,
Pg. 49 CBC 1115B.4.3
The force to activate controls shall be no greater
that 5lbs. force. Lever-operated, push-type, and
electronically controlled mechanisms are example
of
expectable designs. Findings - 15lbs to operate
2 Restroom
Accessories
Item C.1,
Pg. 50 CBC 11B-603.5.
Relocate (or provide same) restroom accessories to
a height of 40" maximum to highest operable parts
above finish floor. Findings - (51" for Towel
Dispenser)
2 Lever on Urinal Item D.1,
Pg. 51 11B-605.4
(Operable Parts) except that the flush control shall
be mounted at a maximum height of 44 inches above
the
finish floor. Findings - 45-1/2" to top of urinal lever 2 Women’s Restroom
Lower Level:
Section
7(B) Cost Estimate: $3,000 $3,397.50
Water Closet
Location
Item A.2,
Pg. 52 CBC 1115B.4.1
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or
partition.
Findings - 18-1/2" from side wall
2 Clear Floor for
Wheelchairs
Item B.2,
Pg. 53-54 11B-305.2
The clear floor or ground space shall be 30 inches
minimum by 48 inches minimum. Findings - trash
receptacle encroaches into the clear floor space
for
the sink
2 Restroom
Accessories
Item C.2,
Pg. 55 CBC 11B-603.5. Findings - 61-1/2" to highest operable part of SanitaryNapkins 2 Coat Hook
Height
Item D.2,
Pg. 56 11B-604.8.3
Coat hooks shall be located within one of the
reach ranges specified in 11B-308 (Reach
Ranges).
Findings - 69" to top of hook.
2 30 | P a g e 78
City of Hermosa Beach
Transition Plan
Violations: City Hall
Pg.
Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Men’s Restroom Upper
Level:
Section
7(C) Cost Estimate: $1,000 $1,132.50
Restroom
Accessories
Item A.3,
Pg. 57 CBC 11B-603.5. Findings - 51" to top of outlet for towel dispenser. 2 Women’s
Restroom Upper
Level:
Sectio
n 7(D) Cost Estimate: $1,500
Exposed Pipes Item A.4,
Pg. 59
CBC
1115B.4.3.4
Provide insulated wrapping around pipes under sink.
Findings - Hot water lines exposed 1
Restroom
Accessorie
s
Item
B.4, Pg.
60 CBC 11B-603.5. Findings - (50" for Towel Dispenser) 2 Drinking Fountains: Section 10 Cost Estimate: $2,500 2,831.25 Knee and
Toe
Clearance
Item A,
Pg. 63-65 ADA 306
Provide the required knee clearance. Space under
an element between 9" and 27" above finish floor
shall be provided. Knee clearance shall extend 25"
maximum under an element at 9" above the finish
floor. Drinking fountain next to lower lever
restrooms. Findings - No knee clearance provided.
Drinking fountain in employee work area / Findings
- No knee
clearance & no clear floor space of 30" by 48"
provided: Not for public access. No Action
Required.
4 Fountai
n
Locatio
n
Item B,
Pg. 66 CBC 11B-602
Drinking fountains shall be located in an alcove,
between wing walls, or positioned not to project
into the accessible route more than 4". Drinking
fountain next to lower lever restrooms. Findings -
Not Provided. Drinking fountain in employee work
area /
Findings - Not Provided Not for public access.
No Action Required.
4 Bubbler Outlet Item C,
Pg. 67-68 ADA 602.4
The spout shall be 15" minimum from the vertical
support and 5" max from the face of the fountain
including bumpers. The height shall be 36"
maximum from finish floor. Findings - 43" to outlet.
Drinking
fountain in employee work area / Findings - 38"
to outlet Not for public access. No Action
Required.
4 Stage Areas: Section 11 Cost Estimate: $15K- $20K for a platform lift. $16,987.50-22,650.00 Accessibl
e Stage
Item A,
Pg. 69
CBC
11B206.2.4
At least one accessible route shall connect
accessible building or facility with all accessible
spaces and elements within a building or facility
which are otherwise connected by a circulation path
unless
exempted by 206.2.3. Findings - No Access
to Council Seats.
3 31 | P a g e
79 City of Hermosa Beach
Transition Plan
j) Civic Center Exterior
City Hall is located at 1315 Valley Dr., The Police and Fire station are located at 540 Pier Ave Violations: Civic
Center
Exterior
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Exterior:
Overall Parking: Section 3 Cost Estimate: $500 for new signs / See Parking Spaces $566.25 section for additional estimated costs.
Number of VanAccessible
Parking Spaces
Pg. 11, Item
B
208.2.4
Six or a fraction of six parking spaces shall be VAN
ACCESSIBLE.
Findings - 1 Van accessible provided at the Library
location. / The single location on the west side of the City
Hall is not a van accessible and should be.
See Parking Spaces section for more information.
1 Tow Away Sign Pg. 11, Item
C
CBC 11B-502.8
Provide a new "Unauthorized Vehicle Tow Away"
(R100B) sign. Findings - Outdated wording and
missing required information. / Incorrect signs
1 Parking
Space 1 –
West Side:
Section
4(B)
Estimated Cost: $250 - To remove and relocate. $283.13
(Estimated cost if parking remains $4000)
Accessible
Route
Pg. 20, Item
A.2 CBC 11B-502.7
Parking shall connect to the shortest possible
accessible route to the accessible entrance/s.
Findings - Violations Found
See "Accessible Routes Exterior" Section
See "Curb Ramps" Section
See "Ramp Location 2" Section
1 Space Signage
and Look
Pg. 21, Item
C.2 CBC 11B.502 Incorrect Sign / Missing $250 Fine 1
Space and Aisle
Slope
Pg. 22, Item
D.2 CBC 11B.502
Violations Found: Exceeds 1:48 (2%) in parking
and/or access aisles (Findings - 3.2% / 4.6%) / 11.0%
in flow line.
1 Stall Striping Pg. 23-24,
Item E.2 CBC 11B.502
Findings - 192" / Space and/or accessible parking
less than 216" (18') in length. (Minor Violation) VAN
Accessible parking required in this location if it
remains in this location. Van Access Aisle less than
96" Minimum (8') measured centerline to centerline.
(Minor Violation) Missing NO PARKING Stencil
1 Parking Spaces 2-
5- S
of Library:
Section
4(C) Cost Estimate: $6000 - Surface modification and post with signs. $6,795.00 Accessible
Route
Pg. 26, Item
A.3 CBC 11B.502
See "Accessible Routes Exterior" Section See "Curb
Ramp" Section
Findings - Violations Found
1 Space Signage
and Look
Pg. 27-28,
Item C.3 CBC 11B.502
Access provided in front of the parking spaces is less
than 48" minimum clear due to sign posts. Missing
"Minimum FINE $250" sign
Incorrect Signs all spaces
Findings - 44" clear width at all posts.
1 Space and Aisle
Slope
Pg. 29, Item
D.3 CBC 11B.502
Violations Found: Exceeds 1:48 (2%) in parking
and/or access aisles (Findings - 2.4% / 2.4% / 2.5%)
Spaces
2-4
1 Stall Striping Pg. 29-31,
Item E.3 CBC 11B.502
Striping not measured 108" centerline to centerline.
(Minor Violation) / Findings - 104" Missing NO
PARKING Stencil - All spaces. Access Aisle less
than 60" Minimum (5') measured centerline to
centerline. Findings - 52" Findings - 192" all spaces / Space and/or accessible parking less than 216" (18')
in length.
1 Path of Travel 11B-307.2 1
32 | P a g e
80 City of Hermosa Beach
Transition Plan
Violations: Civic
Center
Exterior
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Pg. 32-33,
Item F.3
Sign next to Parking Space 5 - Sign shall be 80"
minimum clear as this is a pedestrian way. Findings -
78" clear.
Curb Ramp @
Parking
Location 1:
Section
5(A) Cost Estimate: $3,500 $3,963.75
Slope Pg. 35-36,
Item A.1 CBC 11B-406 Exceeds 1:12 (8.33%) on Ramp Portion Findings -10.3% ramp slope 2 Landings Pg. 36, Item
B.1 CBC 11B-406 Findings - 4.3% cross slopes at blended transition. 2 Detectable
Warning
Pg. 36, Item
C.1
CBC 11B406.5.12 Findings - No Detectable Warning Devices provided 2 Curb Ramp @
Parking
Location 2-5:
Section
5(B)
Cost Estimate: $5000 - Remove existing ramps at each $5,662.50 end and provide 1 compliant curb ramp along
the front of the parking area that is attached to the accessible route.
Slope Pg. 38-39,
Item A.2 CBC 11B-406
Cross Slopes exceed 1:48 (2%) / Findings - 2.4%
cross slopes. Cross Slopes exceed 1:48 (2%) / Ramp
Slopes exceeding 1:12 (8.33%) Findings - 2.9% cross
slopes & 13.7% ramp slopes
2 Accessible Routes
Exterior: Section 6 Cost Estimate: $4000 - $7000 $4,530.00-$7,927.50 Walks Pg. 41-42,
Item A 11B-403
Findings - 5.2% / 2.5% Cross Slopes. Findings - 7.1%
Ramp Slope - (Requires hand railing). Findings -
19.2% Ramp Slope at city sidewalk join. This path of
travel is the only route provided from accessible
parking spaces south of the library. This parking
serves the City Hall, Police and Fire departments and
is required to be accessible.
2 Ramp Location
1 – S of
Library:
Section
7(A) Cost Estimate: $7,500 $8,493.75
Level Landing Pg. 45, Item
A.1 CBC 11B-405.7
(Doors, when fully open, shall not reduce the required
ramp landing width by more than 3 inches. Doors, in
any position, shall not reduce the minimum dimension
of the ramp landing to less than 42 inches.
11B-405.7.5)
Findings - Slope violations at bottom and mid
landings. Bottom Landing - 3.8% in level landing area.
Mid Landing - 4.0% in level landing area
2 Ramp Location 2 –
W
of City Hall Entry:
Section
7(B) Cost Estimate: $12,000 - $15,000 $13,590.00-$16,987.50 Slope Pg. 47, Item
A.2 CBC 11B-405 Findings - 9.3% slopes in the direction of travel (thisarea only) 2 Level Landings Pg. , Item
B.2 CBC 11B-405.7 Findings - Slope violations at mid landings. Findings -3.23% in mid landing 2 Width Pg. , Item
C.2 11B-403 Findings - 47-1/2" clear width / Portions of ramp areless than 48" minimum clear width. 2 Stairways: Section 8 Cost Estimate: $750 $849.38
Stripe Tread Pg. 50, Item
A
11B-504.4.1
Findings - Contrasting stipe not provided. Main entry
stairways east side of City Hall. - No contrasting stripe provided on all treads. Stairs at west side of City Hall entry door. - Not provided
3 33 | P a g e
81 City of Hermosa Beach
Transition Plan
k) City Yard
City Hall is located at 679 Valley Dr.
Violations: City
Yard
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Site Arrival Points: Section 2 Cost Estimate: $4,000 $4,530.00 Accessible
Route
Item A, Pg.
8 CBC 11B-206
At least one accessible route shall be provided within
the boundary of the site from public transportation
stops, accessible parking, and accessible passenger
loading zones, and public streets or sidewalks.
Findings - Not Provided
2 Overall Parking: Section 3 Cost Estimate: $4000.00 / Not clear due to existing conditions $4,530.00 and layout.
Sufficient
Accessible
Parking
Item A, Pg.
10 11B-208.1
TOTAL OVERALL PARKING SPACES PROVIDED =
0 Marked
TOTAL ACCESSIBLE PARKING SPACES
PROVIDED = 0
TOTAL REQUIRED ACCESSIBLE PARKING
SPACES = 1 at animal holding.
1 Sufficient
Number of Van
Accessible
Item B, Pg.
10 CBC 11B208.2.4Six or a fraction of six parking spaces shall be VAN ACCESSIBLE. Findings - Not Provided 1
Tow Away Sign Item C, Pg.
11 CBC 11B-502.8 Provide a new "Unauthorized Vehicle Tow Away"(R100B) sign 1 Accessible
Routes
Exterior:
Section 5 Cost Estimate: $4000 - Design Required. $4,530.00 Walks Item A, Pg.
17 CBC 11B-206
There is no clear route at this facility. The access
from the public right of way is through driveways and
opens to a large asphalt maintenance yard. Design
and new routes will need to be evaluated and
designed to meet full compliance for access to the
animal holding center.
2 Entrance Doors: Section 6 Cost Estimate: $2,500 $2,831.25 Door Hardware Item A, Pg.
19 CBC 11B-404-2-
7 Provide door hardware mounted between 34" and 44"
above finish floor. Findings - Twist Type door knob 3
Maneuvering
Space
Item B, Pg.
19-20 CBC 11B-404
The floor or ground space within the required
clearances shall be level and clear. Suite 27762 -
5.2% in level maneuvering space
3 Strike Side
Clearance
Item C, Pg.
20 11B-404.2.4.3
Maneuvering clearances for forward approach shall
be provided
when any obstruction within 18 inches of the latch
side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than
8 inches beyond the face of the door, measured
perpendicular to the face of the door or gate.
Findings - 9" on pull side of door. (18" required)
3 Threshold Item D, Pg.
21 CBC 11B404.2.5
Provide or modify door threshold or raise
maneuvering space so that the floor or landing shall
not be more than 1/2" lower than the top of the
threshold of the doorway. Changes in level between
1/4" and 1/2" shall be beveled with a slope no greater
than 1:2. Findings - 2-1/2" change in elevation
3 Miscellaneous
Doors:
Section 7 Cost Estimate: $3000 - No Action Required. $3,397.50 Accessible Door Item A, Pg.
23-25
Findings - 27" clear wide. Findings - 29-1/2" clear
wide / Door to offices. Findings - 30" clear width. /
Men's Restroom Door - No Action Required.
4 Door Hardware Item B, Pg.
26 CBC11B-404-2-
7 Findings - Twist Type door knob 4
34 | P a g e
82 City of Hermosa Beach
Transition Plan
Violations: City
Yard
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Door Closing
Speed
Item C, Pg.
26 CBC 11B404.2.8.1
Adjust or provide door closure so that from an
opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch,
measured from the leading edge of the door. Findings
- 3 Seconds 90-12
4 Pull/Push Force Item D, Pg.
27 CBC 11B404.2.9
Modify door pull/push force to maximum of 5lbs of
pressure 30" from the hinge or the door hardware
whichever is furthest from the hinge. Findings - 7lbs.
Minor violation
4 Maneuvering
Space
Item E, Pg.
27-28 CBC 11B-404
The floor or ground space within the required
clearances shall be level and clear. Findings - 7.6% /
Slopes exceed 1:48 (2%) in maneuvering Space
4 Strike Side
Clearance
Item F, Pg.
29 11B-404.2.4.3 Findings - Strike side clearance not provided on thepull side of door. 4 Threshold Item G, Pg.
29-30
CBC 11B404.2.5
Findings - 1" to top of threshold. No Action Required
for this door. Findings - 2" to top / Greater than 1/2 in. maximum for top of threshold to maneuvering space.
4 Kitchens &
Kitchenettes: Section 8 Cost Estimate: $3000 - No Action Required $3,397.50 Lavatory Heights Item A, Pg.
32 CBC 11B-606
All lavatories that are designated to be accessible
shall be a minimum of 17" in horizontal depth and
mounted with the rim or counter edge no higher than
34" above finish floor with a vertical clearance
measured from the bottom of the apron or the outside
bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. Findings -
36" to top of sink.
4 Sink Knee
Clearance
Item B, Pg.
33 CBC 11B-603
Provide knee clearance at lavatory. Findings - If this
sink was modified or altered, It would require a clear
floor space and the proper knee clearance under the
sink.
4 Ranges or
Cooktop Control
Location
Item C, Pg.
34 11B-804.6.4
Where a forward approach is provided, the clear floor
or ground space shall provide knee and toe clearance
complying with 11B- 306 (Knee and Toe Clearance).
Findings - Forced to reach over stove top.
4 Restrooms: Section 9 Cost Estimate: $15,000 - No Action Required $16,987.50 Proper Signs Item A, Pg.
39 11B-216.8
Doorways leading to toilet rooms and bathing rooms
complying with 11B- 603 (Toilet and Bathing Rooms).
Findings - Proper signs not provided.
4 Door Swing Item B, Pg.
39 11B-603.2.3
Doors shall not swing into the clear floor space or
clearance required for any fixture.
Other than the door to the accessible water closet
compartment, a door, in any position, may encroach
into the turning space by 12 inches maximum.
Findings - Door swings in and encroaches greater
than 12" into clear turning space. It is recommended
to provide new compliant door and swing the door out
to prevent encroachment into 60" turning space.
4 Clearance at
Water Closet
Item C, Pg.
40-41 11B-604.3
Clearance around a water closet shall be 60 inches
minimum measured perpendicular from the side wall
and 56 inches minimum measured perpendicular from
the rear wall. Findings - 44" wide. When shower is
removed the proper space will be achieved.
4 Grab Bars Item D, Pg.
42 CBC 11B604.5.2
Grab Bars shall be 36" long and mounted 33" to 36"
measured to the top of the grab bar. Findings - Not
Provided
4 Water Closet
Location
Item J, Pg.
43 CBC 1115B.4.1
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or partition.
Findings - Not positioned correctly. 16" from side wall (Incorrect wall)
4 35 | P a g e
83 City of Hermosa Beach
Transition Plan
Violations: City
Yard
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Water Closet
Seat Cover
Location
Item K, Pg.
44 CBC
1115B.4.1.4
Install water closet with a seat height of 17" - 19"
above finish floor. Findings - 16" to top of seat 4
Sink Knee
Clearance
Item M, Pg.
45-46 CBC 11B-603
Provide knee clearance at lavatory. Findings - Sink
does not provide proper knee clearance. Findings -
Remove pedestal sink.
4 Faucet Controls Item N, Pg.
47 CBC 1115B.4.3 Install sink controls that do not require tight grasping,pinching or twisting. Findings - Twist type controls 4 Sink Location Item O, Pg.
47 CBC 11B-606
Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall
or partition. Findings - Minor violation 17-1/2" from
side wall
4 Exposed Pipes Item P, Pg.
48 CBC
1115B.4.3.4
Provide insulated wrapping around pipes under sink.
Findings - Exposed 4
Mirror Location Item Q, Pg.
48 11B-603.3
Mirrors located above lavatories or countertops shall
be installed with the bottom edge of the reflecting
surface 40 inches maximum above the finish floor or
ground. Findings - 51-1/2" Greater than 40" to
reflective surface.
4 Restroom
Accessories
Item R, Pg.
50 CBC 11B-603.5.
Relocate (or provide same) restroom accessories to a
height of 40" maximum to highest operable parts
above finish floor. Findings - (41" Soap Dispenser) (
52" for Towel Dispenser) (Seat Covers / No clear floor
space)
4 Toilet Tissue
Dispenser
Location
Item S, Pg.
51 11B-604.7
Toilet paper dispensers shall comply with 11B-309.4
(Operation) and shall be 7 inches minimum and 9
inches maximum in front of the water closet measured
to the centerline of the dispenser. Findings - Incorrect mounting location
4 Coat Hooks Item T, Pg.
51 11B-604.8.3
Coat hooks shall be located within one of the reach
ranges specified in 11B-308 (Reach Ranges).
Findings - 69" to top of hook
4 Unisex Restroom
Door:
Section 10 Cost Estimate: $1500 - No Action Required $1,698.75 Accessible Door Item A, Pg.
53 CBC 11B-404 Provide 32" clear width from face of door at 90deg toopposite stop. Findings - 29-1/2" clear width. 4 Door Hardware Item B, Pg.
54 11B-404-2-7
Provide door hardware mounted between 34" and 44"
above finish floor. Findings - Twist Type door knob. 4
Strike Side
Clearance
Item C,
Pg.54 11B-404.2.4.3 Findings - 4" on pull side of door. 4 36 | P a g e
84 City of Hermosa Beach
Transition Plan
l) Base 3
Base 3 is located at NE corner of 11th St and Valley Dr.
Violations: Base 3
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Exterior:
Site Arrival Points: Section 2 Cost Estimate: $2500 - For access to building only. $2,831.25 Ramp design or alternate path of travel required.
One Accessible
Route
Item A,
Pg. 7-8
CBC 11B-206
At least one accessible route shall be provided within
the boundary of the site from public transportation
stops, accessible parking, and accessible passenger
loading zones, and public streets or sidewalks.
Findings - 8.7% ramp slope (See Ramp Section).
Joining sidewalk has slopes greater than 1:48 (2%).
This is a turning space and shall not exceed 2% in all
directions.
2 Walks Item B,
Pg. 8-11 11B-403
Provide compliant walks for accessible routes with 48"
minimum width, 1:48 (2%) or less cross slopes & 1:20
(5%) or less running slopes. Findings - All sidewalks
surrounding the building have cross slope and minor
width violations. This may be included in other reports outside of ADAIP.
2 Overall Parking: Section 3 Cost Estimate: $250 $283.13 Accessible Route Item A,
Pg. 11 CBC 11B-502.7
Parking shall connect to the shortest possible
accessible route to the accessible entrance/s.
Findings - See "Accessible Routes Exterior" section
1 “Unauthorized
Vehicle Tow
Away” Sign
Item D,
Pg. 12-13 CBC 11B-502.8 Findings - Incorrect - Outdated wording and missing required information. 1 Parking Space 1 & 2: Section
4(B) Cost Estimate: $4,000 $4,530.00
Accessible Route Item A.2,
Pg. 20 CBC 11B-502.7 Findings - See "Accessible Routes Exterior" Section 1 Proper Marking for
Accessible Spaces Item B.2,
Pg. 21
CBC 11B502.7.1
Missing "Minimum FINE $250" sign This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to eliminate
the potential for litigation.
1 Accessible
Parking Slopes
Item C.2,
Pg. 22
2013 CBC 11B502.6.Violations Found: Exceeds 1:48 (2%) in parking and/or access aisles (Findings - 3.7% / 2.7% / 3.0%) 1
Accessible Stall
Striping
Item D.2,
Pg. 23-24 CBC 11B-502.4
Findings - 181" / Space and/or accessible parking
less than 216" (18') in length. (Minor Violation).
Missing NO PARKING Stencil. Diagonal Lines in
access aisles are greater than 36" measured
centerline to centerline. (Minor Violation). Faded -
Maintenance Required
1 Parking Space 3: Section
4(C) Cost Estimate: $250 $283.13
Accessible Route Item A.3,
Pg. 25 CBC 11B-502.7 See "Accessible Routes Exterior" Section 1 Proper Marking for
Accessible Spaces Item B.3,
Pg. 26 11B-502.7.1
Missing "Minimum FINE $250" sign This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to eliminate
the potential for litigation.
1 Accessible
Parking Slopes
Item C.3,
Pg. 27 CBC 11B-502.6. Violations Found: Exceeds 1:48 (2%) in parkingand/or access aisles (Findings - 11.0%) 1 Accessible Stall
Striping
Item D.3,
Pg. 28 CBC 11B-502.4 No Access aisle / Parking space less than 108"minimum wide 1 Accessible Routes
Exterior: Section 5 Cost Estimate: $20,000 $22,650.00
37 | P a g e
85 City of Hermosa Beach
Transition Plan
Violations: Base
3 Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Walks Item A,
Pg. 28-34 11B-403
Provide compliant walks for accessible routes with 48"
minimum width, 1:48 (2%) or less cross slopes & 1:20
(5%) or less running slopes. In front of Parking 1 & 2
to Base 3 Building 3.4% / 3.1% cross slopes. From
Parking 1 & 2 to Base 3 Building / Findings - Less
than 48" minimum wide. From Parking 1 & 2 to Base
3 Building / Findings - (10.8%) Slopes in the direction of travel exceed 1:12 (8.33%). From Parking 1 & 2 to
Base 3 Building / Findings - (6.6%) / Slopes exceed
1:20 (5%) and shall be considered a "RAMP"
(Landings and Hand railing Required). From Parking
1 & 2 on walkway to Base 3 Building / 3.0% cross
slopes. From Parking 1 & 2 on walkway to Base 3
Building / Findings - (10.4%) Slopes in the direction of travel exceed 1:12 (8.33%). From Main Walkway to
Base 3 Building (Kitchen) / Findings - (3.4%) Widths
less than 48" minimum wide (No Violation with the
ADA for width)
2 Stairways: Section 6 Cost Estimate: $4500 for new railing only $5,096.25 Hand Railing Item A,
Pg. 36 11B-505.2 Handrails shall be provided on both sides of stairs and ramps. Findings - Railing on one side only. 4 Railing
Requirements
Item B,
Pg. 36 11B- 504.6 Findings - Less than 12" parallel with landing surface. 4 Entrance Doors: Section 7 Cost Estimate: $250 $283.13
Door with Closure
Speed
Item A,
Pg. 37
CBC 11B404.2.8.1
Adjust or provide door closure so that from an
opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch,
measured from the leading edge of the door. Findings
- 2 Seconds 90-12
2 Pull/Push Force Item B,
Pg. 38
CBC 11B404.2.9
Modify door pull/push force to maximum of 5lbs of
pressure 30" from the hinge or the door hardware
whichever is furthest from the hinge. Findings - 13lbs
2 Miscellaneous
Doors:
Section 8 Cost Estimate: $7,000 $7,927.50
Accessible Door Item A,
Pg. 39-42 CBC 11B-404
Provide 32" clear width from face of door at 90deg to
opposite stop. Door 3' wide by 6'-8" shall be provided.
Accessibility Required-Door to left office / information area. Findings - 28" clear width. Misc. Interior Doors
Less than 32" Minimum clear wide. Accessibility
Required These doors MAY need to meet compliance
if the public enters this room for use.
4 Door Hardware Item B,
Pg. 43-46
CBC 11B-404-2-
7 Provide door hardware mounted between 34" and 44"
above finish floor. Hardware shall be easy to grasp
with one hand and shall not be required to twist with
the wrist, grasp tightly or does not require tight
pinching. Findings - Twist Type door knob.
Accessibility Required Door to left office / service
area. Misc. Interior Doors - Twist type. / Slide lock is greater than 44" above the floor
4 Door with Closure
Speed
Item C,
Pg. 46-47
CBC 11B404.2.8.1
Adjust or provide door closure so that from an
opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch,
measured from the leading edge of the door. Door top
Exit from corridor / Findings - 3 Seconds 90-12
4 Pull/Push Force Item D,
Pg. 47
CBC 11B404.2.9
Modify door pull/push force to maximum of 5lbs of
pressure 30" from the hinge or the door hardware
whichever is furthest from the hinge. Door top Exit
from corridor / Findings - 8 lbs.
4 Maneuvering
Space
Item E,
Pg. 48-49 CBC 11B-404
The floor or ground space within the required
clearances shall be level and clear. Provide door
landing on the exterior side of the entrance door. The
floor or ground area within the required clearances
shall be level and clear. Findings - (38") 60" required on the pull side of door. Maneuvering space too small.
4 38 | P a g e
86 City of Hermosa Beach
Transition Plan
Violations: Base
3 Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Strike Side
Clearance
Item F,
Pg. 50-51 11B-404.2.4.3
Maneuvering clearances for forward approach shall
be provided when any obstruction within 18 inches of
the latch side of an interior doorway, or within 24
inches of the latch side of an exterior doorway,
projects more than 8 inches beyond the face of the
door, measured perpendicular to the face of the door
or gate. Exit Door from corridor - Less than 24" strike side maneuvering space / 4.4% in maneuvering
space
3 Exits Identified Item G,
Pg. 52-53 CBC 11B-703 Provide tactile EXIT sign at exit doors. Findings - Notprovided / Illuminated EXIT's require tactile signs. 2 Threshold Item H,
Pg. 54-55
CBC 11B404.2.5
Provide or modify door threshold or raise
maneuvering space so that the floor or landing shall
not be more than 1/2" lower than the top of the
threshold of the doorway. Changes in level between
1/4" and 1/2" shall be beveled with a slope no greater
than 1:2. Accessibility Required This door MAY need
to meet compliance if the public enters this room for
use. Door top exterior from kitchen / 3" from outside / 1" interior
3 Smooth Surface
of 10” at Bottom
of Door
Item I, Pg.
55-56
CBC 11B404.2.10
Provide a 10" smooth panel on the push side of door
or gate. Door to exterior form kitchen area & Exit Door from corridor / Lock mounted in 10" smooth area on
push side of door.
3 Accessible Routes
Interior: Section 9 Cost Estimate: $2,500 $2,831.25
Interior Path of
Travel
Item A,
Pg. 57-58 CBC 11B-403
Provide 36" minimum clear width in accessible path of
travel. Every portion of every building in which are
installed seats, tables, merchandise, equipment or
similar materials shall be provided with aisles leading to an exit. Access to the Men's restroom is not an
accessible route.
4 Path of Travel Item B,
Pg. 58-59 11B-307.2
Objects with leading edges more than 27 inches and
not more than 80 inches above the finish floor or
ground shall protrude 4 inches maximum horizontally
into the circulation path. Dutch Door shelving exceeds
requirements for an accessible route. This door
passage is an accessible route.
4 Reach Ranges for
Operable Parts: Section 10 Cost Estimate: $250 $283.13
Reach Range
Requirements
Item A,
Pg. 60-61 11B-308.2
Where a forward reach is unobstructed, the high
forward reach shall be 48 inches maximum and the
low forward reach shall be 15 inches minimum above
the finish floor or ground. Notification Buzzer - Does
NOT meet "Safe Harbor" Requirements of 54" to top if
installed before March 15, 2012. Fire Extinguishers
are required to be at 48" to handle for current code. It is recommended to lower top 48".
3 Kitchens &
Kitchenettes:
Section 11 Cost Estimate: $2,000 $2,265.00
Lavatory Heights Item A,
Pg. 63 CBC 11B-606
All lavatories that are designated to be accessible
shall be a minimum of 17" in horizontal depth and
mounted with the rim or counter edge no higher than
34" above finish floor with a vertical clearance
measured from the bottom of the apron or the outside
bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending
back toward the wall to a distance 6" from the back
wall. The toe clearance space must be free of
equipment or obstructions. Provide (1) accessible
lavatory if this is used by the public.
3 Men’s Restroom
Door:
Section
12(A) Cost Estimate: $3,000 $3,397.50
39 | P a g e
87 City of Hermosa Beach
Transition Plan
Violations: Base 3
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Proper Signs Item A.1,
Pg. 65-66
11B-216.8 Tactile Sign shall be mounted on the wall next to the door / Geometric sign not provided Sing on door shall
be mounted at 60" +/- 1" to center of sign
3 Door Hardware Item B.1,
Pg. 66
CBC 11B-404-
2- 7
Provide door hardware mounted between 34" and 44"
above finish floor. Findings - Twist Type door knob 3
Accessible Door Item C.1,
Pg. 67 CBC 11B-404 Provide 32" clear width from face of door at 90deg toopposite stop. Findings - 21-1/2" clear width. 3 Maneuvering Space Item D.1,
Pg. 68 CBC 11B-404
The floor or ground space within the required
clearances shall be level and clear. Findings - 29" on
the pull side of door
3 Women’s Restroom
Doors:
Section
12(B) Cost Estimate: $3,000 $3,397.50
Proper Signs Item A.2,
Pg. 70-71 11B-216.8
Tactile Sign mounted on door shall be mounted on
wall beside door / Geometric sign not provided for
door. Findings - Incorrect Mounting Location.
3 Door Hardware Item B.2,
Pg. 71
CBC 11B-404-
2- 7
Provide door hardware mounted between 34" and 44"
above finish floor. Findings - Twist Type door knob 3
Accessible Door Item C.2,
Pg. 72 CBC 11B-404 Provide 32" clear width from face of door at 90deg toopposite stop. Findings - 21-1/2" clear width. 3 Men’s Restroom: Section
13(A) Cost Estimate: $10,000 $11,325.00
Location Item A.1,
Pg. 73 CBC 11B-213
Objects with leading edges more than 27 inches and
not more than 80 inches above the finish floor or
ground shall protrude 4 inches maximum horizontally
into the circulation path. Cross bar at top of partition door is less than 80" minimum clear.
3 Grab Bars Item C.1,
Pg. 75
CBC
11B604.5.2
Findings - Not Provided. 3
Water Closet
Location
Item D.1,
Pg. 76 CBC 1115B.4.1 Findings – 16” from Side wall. 3
Sink Location Item E.1,
Pg. 77 CBC 11B 606.6 Findings – 17-1/2” from side wall. 3 Knee clearance Item F.1,
Pg. 78 CBC 11B-603 Findings- pedestal sinks are not accessible – kneeclearance not provided. 3 Mirror Location Item H.1,
Pg. 79 CBC 11B-603.3 Findings – 52-1/2”/Greater than 40” to reflectivesurface. 3 Restroom
Accessories
Item I.1,
Pg. 80 CBC 11B-603.5 Findings- Accessories greater than 40” above floor. 3 Women’s Restroom: Section
13(B) Cost Estimate: $6,000 $6,795.00
Location Item A.2,
Pg. 82 CBC 11B-213 Findings- Door width violations. 3
Door Swing Item B.2,
Pg. 82 11B-603.2.3 Findings- Door swings more than 12” into 60” turningspace. 3 Grab Bars Item D.2,
Pg. 83
CBC 11B604.5.2 Findings - Not Provided. 3
Water Closet
Location
Item I.2,
Pg. 84 CBC 1115B.4.1 Findings – 15” from Side wall. 3
Water Closet Seat
Cover
Item J.2,
Pg. 84
CBC
1115B.4.1.4 Findings – 15-1/2” AFF 3
Sink Location Item K.2,
Pg. 85 CBC 11B 606.6 Findings – 13” from Side wall. 3
Knee Clearance Item L.2,
Pg. 86 CBC 11B-603 Findings- pedestal sinks are not accessible – kneeclearance not provided. 3 Faucet Controls Item N.2,
Pg. 87 CBC 1115B.4.3 Findings – Twist type controls. 3
Mirror Location Item O.2,
Pg. 87 CBC 11B-603.3 Findings – 52”/Greater than 40” to reflective surface. 3 Restroom
Accessories
Item P.2,
Pg. 88 CBC 11B-603.5 Findings- Accessories greater than 40” above floor. 3 Drinking Fountains Section
14 Cost Estimate: $2,000 $2,265.00
40 | P a g e
88 City of Hermosa Beach
Transition Plan
Violations: Base
3 Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Knee Clearance Item A.,
Pg. 89 ADA 306 Findings- Knee Clearance Not Provided 3
Location Item B,
Pg. 90 CBC 11B-602 Findings- No alcove or railing protection provided 3 Bubbler Outlet Item C,
Pg. 91 ADA 602.4 Findings – 43” 3
Electrical Switches Section 15
Cost Estimate: $250/ Not Required $283.13
Switch Height Item A,
Pg. 92 11B-308.1.1 Findings – (60”) / Light switch in break room 4 41 | P a g e
89 City of Hermosa Beach
Transition Plan
m) South Park
South Park is located at 425 Valley Dr.
Violations: South
Park
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Site Arrival Points: Section 2
Accessible Route Item A,
Pg. 7. CBC 11B206
At least one accessible route shall be provided within the boundary of the site from public transportation stops,
accessible parking, and accessible passenger loading
zones, and public streets or sidewalks.
Findings - Access from Valley Dr. is accessed through the park. Slope violations found.. See "Accessible
Routes Exterior" section. Access From Loma Dr. is
vehicle access only providing no pedestrian access.
2 Overall Parking: Section 3 Cost Estimate: $250 for sign only / See Parking section for estimated cost to provide VAN Accessible Parking $283.13 Sufficient Number
of Van-Accessible
Parking
Item B,
Pg. 10.
CBC
11B208.
2.4 Six or a fraction of six parking spaces shall be VAN ACCESSIBLE. Findings - No Van Parking Provided
Reconfigure parking to meet VAN Accessible
requirements.
1 Tow Away Sign Item C,
Pg. 11. CBC 11B502.8
Provide a new "Unauthorized Vehicle Tow Away" (R100B)
sign. Findings - Outdated wording and
missing required information.
1 Parking Spaces: Section 4 Cost Estimate: $4,000 $4,530.00 Accessible Route Item A,
Pg. 12. See "Accessible Routes Exterior" Section 1
Accessible
Spaces Marked
Properly
Item C,
Pg. 13-14. CBC 11B502.6.
Signs shall be provided at spaces for each parking stall space for persons with disabilities. Incorrect Sign
/ Missing "VAN Accessible" sign
1 Accessible Space
and Aisle Slope
Item D,
Pg. 15. CBC 11B502.4
Surfaces shall not exceed 1:48 (2%) max slope in any
direction at accessible parking spaces and access aisle.
Findings - 3.9% / 3.2%
1 Accessible Stall
Striping
Item E,
Pg. 16-19. CBC
11B.502
Stripe accessible parking space with 36"x36" ISA (White on Blue), 216" (18') long 108" (9') wide with blue
boarder measured centerline to centerline.
Striping not measured 108" centerline to centerline.
Missing Edge Line or Border (Minor Violation).
Findings - 39" / Diagonal Lines in access aisles are
greater than 36" measured centerline to centerline.
(Minor Violation). Missing NO PARKING Stencil.
1 Accessible
Routes
Exterior:
Section 5 Cost Estimate: $40,000 - $60,000 / Design and realignment for new ramp may be necessary to meet full compliance to connect the upper $45,300.00-67,950.00 and lower levels of this building.
Walks Item A,
Pg. 20-29. 11B-403
Provide compliant walks for accessible routes with 48"
minimum width, 1:48 (2%) or less cross slopes & 1:20
(5%) or less running slopes. Cross Slopes
exceed 1:48 (2%) 48" minimum wide clear.
2 Change in Level Item B,
Pg. 30.
Changes in level up to 1/4" may be vertical and without edge treatment. Changes in level between 1/4" and 1/2"
shall be beveled with a slope no greater than one unit
vertical in 2 units horizontal (50% slope). Access from Valley Rd to lower level of
building. / Findings - 1" change in elevation.
2 Stairways: Section 7 Estimated Cost: $25,000 In railing to meet requirements if an elevator or accessible ramp is NOT provided. It is recommended to provide $28,312.50 accessible hand railing.
Railing Location Item B,
Pg. 35-36. CBC 11B505.4
Provide railing on both sides of ramp at 34"-38" to top of railing from ramp surface and consistent in height.
Findings - 45" / 40" to top of railing.
4 Railing Extension Item C,
Pg. 37.
CBC
11B505.
10.3 Modify handrail to extend a minimum of 12" beyond the top nosing and 12" plus tread width, beyond the bottom
nosing. Findings - Not Provided at any stair
sections at this facility.
4 42 | P a g e
90 City of Hermosa Beach
Transition Plan
Violations: South
Park
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Stair Striping Item D,
Pg. 38-39. 11B-504.4.1
Exterior stairs shall have the upper approach and all
treads marked by a stripe providing clear visual
contrast. Findings - Grooves are not contrasting. Paint stripe for contrasting affect.
2 Entrance Doors: Section 8 Cost Estimate: $10,000 due to threshold height. $11,325.00 Door Hardware Item A,
Pg. 40-41.
CBC 11B-404-2-
7 Hardware shall be easy to grasp with one hand and
shall not be required to twist with the wrist, grasp
tightly or does not require tight pinching. Findings -
Twist Type door knob
2 Door Closing
Speed
Item B,
Pg. 41-42.
CBC 11B404.2.8.1
Adjust or provide door closure so that from an
opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch,
measured from the leading edge of the door. Room 3
/ Findings - 3 Seconds 90-12. Room 2 / Findings - 3
Seconds 90-12. Room 1 / Findings - 3 Seconds 90-
12 2
Door Closure
Height
Item C,
Pg. 42-43.
CBC 11B404.2.3
Modify door closure to be a minimum of 78" clear
above finish floor or ground. Room 1 / Findings - 77".
Room 2 / Findings - 77". Room 3 / Findings - 77".
3 Pull/Push Force Item D,
Pg. 44.
CBC 11B404.2.9
Modify door pull/push force to maximum of 5lbs of
pressure 30" from the hinge or the door hardware
whichever is furthest from the hinge. Room 3 /
Findings - 8lbs.
2 Threshold Item E,
Pg. 45.
CBC 11B404.2.5
Provide or modify door threshold or raise
maneuvering space so that the floor or landing shall
not be more than 1/2" lower than the top of the
threshold of the doorway. Findings - 1-1/2" to top of
threshold.
2 Smooth Surface
on Push Side of
Door
Item F,
Pg. 45-46.
CBC 11B404.2.10
Provide a 10" smooth panel on the push side of door
or gate. Room 1 / Findings - Door Stop in 10" smooth
area. Room 2 / Findings - Door Stop in 10" smooth
area. Room 3 / Findings - Door Stop in 10" smooth
area
3 Reach Ranges for
Operable Parts: Section 9 Cost Estimate: $500 $566.25
Reach Range
Requirements
Item A,
Pg. 49-50. 11B-308.2
Where a forward reach is unobstructed, the high
forward reach shall be 48 inches maximum and the
low forward reach shall be 15 inches minimum above
the finish floor or ground. Fire Extinguishers are
required to be at 48" to handle for current code. It is recommended to lower top 48". Findings - 61-1/2" to
top of highest operable part / Outside Reach Range
Requirements.
3 Men’s Restroom
Door:
Section
10(A) Cost Estimate: $3,000 $3,397.50
Proper Signs Item A.1,
Pg. 52. 11B-216.8
Doorways leading to toilet rooms and bathing rooms
complying with 11B- 603 (Toilet and Bathing Rooms)
shall be identified by a geometric symbol complying
with 11B- 703.7.2.6.
1 Door Hardware Item B.1,
Pg. 53.
CBC 11B-404-2-
7 Provide door hardware mounted between 34" and 44"
above finish floor. Findings - Handle located out of
required range. 53"-56" Lock located 48" to top. 44"
for new doors (48" not a violation of the ADA)
(Violation of CA Building code requirements.)
1 Maneuvering
Space
Item C.1,
Pg. 53-54. CBC 11B-404
The floor or ground space within the required
clearances shall be level and clear. Slopes exceed
1:48 (2%) in maneuvering Space / Findings - 4.0%
1 Door Closure
Height
Item D.1,
Pg. 54.
CBC 11B404.2.3 Findings - Less than 78" minimum clear 1 Threshold Item E.1,
Pg. 55.
CBC 11B404.2.5 Findings - 2" to top of threshold 1
43 | P a g e
91 City of Hermosa Beach
Transition Plan
Violations: South Park
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Smooth Surface
on Push Side of Door Item F.1,
Pg. 55.
CBC 11B404.2.10 Findings - Door stop on push side. 1
Women’s Restroom
Doors:
Section
10(B) Cost Estimate: $3,000 $3,397.50
Proper Signs Item A.2,
Pg. 59. 11B-216.8 Tactile Sign Not Provided / Geometric sign notmounted on the door. 1 Door Hardware Item B.2,
Pg. 59.
CBC 11B-404-2-
7 Findings - Lock at 54" to top. 1
Closing Speed Item C.2,
Pg. 59.
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12 1
Maneuvering Space Item D.2,
Pg. 60-61. CBC 11B-404 Slopes exceed 1:48 (2%) in maneuvering Space / Findings - 3.0% 1 Door Closure
Height
Item E.2,
Pg. 61.
CBC 11B404.2.3 Findings - Less than 78" minimum clear 1 Threshold Item F.2,
Pg. 62.
CBC 11B404.2.5 Findings - 2" to top of threshold 1
Smooth Surface
on Push Side of Door Item G.2,
Pg. 62.
CBC 11B404.2.10 Findings - Door stop on push side of door. 1 Men’s Restroom: Section
11(A) Cost Estimate: $6,000 $6,795.00
Path of Travel Item A.1,
Pg. 65. 11B-307.2
Objects with leading edges more than 27 inches and
not more than 80 inches above the finish floor or
ground shall protrude 4 inches maximum horizontally
into the circulation path. Cross bar at top of partition door is less than 80" minimum clear.
1 Floor or Ground
Surfaces Slope
Item B.1,
Pg. 66. 11B-304.2
Floor or ground surfaces of a turning space shall
comply with 11B-302(Floor or Ground Surfaces).
Changes in level are not permitted. Findings - 10.6%
in front of urinals
1 Clearance at
Water Closet
Item C.1,
Pg. 67-68. 11B-604.3 Findings - Not Provided 1
Grab Bars Item D.1,
Pg. 68.
CBC 11B604.5.2 Findings - Not Provided 1
Sink Knee
Clearance
Item N.1,
Pg. 70. CBC 11B-603 Findings - Less than 27" minimum clear kneeclearance. 1 Exposed Pipes Item O.1,
Pg. 71.
CBC
1115B.4.3.4 Findings - Exposed 1
Restroom
Accessories
Item P.1,
Pg. 72. CBC 11B-603.5. Findings - (48" Soap Dispenser) ( 49" for Towel Dispenser) 1 Women’s Restroom: Section
11(B) Cost Estimate: $4,000 $4,530.00
Floor or Ground
Surfaces Slope
Item A.2,
Pg. 75. 11B-304.2 Findings - 2.4% under sink 1
Clearance at
Water Closet
Item B.2,
Pg. 76-77. 11B-604.3 Findings - Not provided 1
Grab Bars Item C.2,
Pg. 77.
CBC 11B604.5.2 Findings - Not Provided 1
Sink Location Item M.2,
Pg. 78. CBC 11B 606.6
Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink. A
clear floor space shall be provided for forward
approach. Findings - 13-1/2" from side wall to center.
1 Exposed Pipes Item O.2,
Pg. 78.
CBC
1115B.4.3.4 Findings - Exposed 1
Restroom
Accessories
Item P.2,
Pg. 79. CBC 11B-603.5. Findings - ( 61" for Towel Dispenser) 1 Electrical Switches: Section 12 Cost Estimate: $3,500 $3,963.75 44 | P a g e
92 City of Hermosa Beach
Transition Plan
Violations: South
Park
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Switch Height Item A,
Pg. 80-.
11B-308.1.1
Controls and switches intended to be used by the
occupant of a room or area to control lighting and
receptacle outlets, appliances or cooling, heating and
ventilating equipment, shall comply with 11B-308
except the low reach shall be measured to the bottom
of the outlet box and the high reach shall be
measured to the top of the outlet box. Findings Room
1, 2, and 3 56” to top of light Switch.
3 45 | P a g e
93 City of Hermosa Beach
Transition Plan
n) Community Center and Theatre
The Community Center and Theatre are located at 710 Pier Ave.
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Site Arrival Points: Section 2 See "Accessible Routes Exterior" section for cost estimates.
Accessible Route Item A,
Pg. 7 CBC 11B206
At least one accessible route shall be provided within the boundary of the site from public transportation stops,
accessible parking, and accessible passenger loading
zones, and public streets or sidewalks. See
"Accessible Routes Exterior" Section.
2 Overall Parking: Section 3 Difficult to estimate. This is very dependent on design and feasibility.
Estimated Cost: $100,000 - $250,000 to provide accessible parking $113,250.00-$283,125.00 with an accessible route to ground level entrancedoors.
Accessible
Parking Spaces
Item A,
Pg. 9 11B-208.1
TOTAL OVERALL PARKING SPACES PROVIDED =
123 parking spaces provided combined. NOTE: The lower
level parking has a total of (106). (2) Serve the main
buildings and (1) serves the tennis courts. This area alone would require 5 accessible parking spaces. The 11th Pl
street parking has a total of (17) and only (1) accessible parking space required at this location. It is recommended to provide at least (1) or more in this area if it is technically feasible to do so. Site survey required. TOTAL
ACCESSIBLE PARKING SPACES PROVIDED = 9 TOTAL
REQUIRED ACCESSIBLE PARKING SPACES = (5)
in lower level / (1) at 11th Pl
NOTE: It is recommended to provide as many as
possible in recommended location.
1 Van-Accessible
Parking Spaces
Item B,
Pg. 9
CBC 11B208.2.4Six or a fraction of six parking spaces shall be VAN ACCESSIBLE. Findings - None provided. 1
Tow Away Sign Item C,
Pg. 10-11 CBC 11B502.8.
Provide a new "Unauthorized Vehicle Tow Away" (R100B)
sign with the proper information with a minimum 17"x22" with 1" lettering at each site entrance or in view of each accessible space.
Findings - Outdated wording / Incorrect sign and missing required information. It is recommended to
provide a new R100B with the required information at each driveway entrance.
1 Parking Space 1 &
2:
Section
4(B) Estimated Cost: See "Overall Parking" section.
Accessible Route Item A.2,
Pg. 18 CBC 11B502.7
Parking shall connect to the shortest possible accessible route to the accessible entrance/s. Findings - The elevation from the parking surface to the ground level for the
buildings is approximately 60"
- Stairs are the only proved route. Stairs cannot be part of an accessible route.
1 Parking
Requirements
Item B.2,
Pg. 12
CBC
11B502.
7.1 A bumper or curb must be placed to prevent encroachment of cars. The spaces must be located so a person with a
disability is not compelled to wheel or walk behind parking spaces other than that
person's own space.
1 Accessible Space
Identification
Item C.2,
Pg. 19
2013 CBC
11B502.6.
Missing "Minimum FINE $250" sign. This is not considered a barrier under the ADA, however, it is recommended to
provide current signs to eliminate the potential for
litigation. Mounting height of 60" min from ground surface to bottom of sign not provided.
Incorrect Sign.
1 Accessible
Parking Slope
Item D.2,
Pg. 20 CBC 11B502.4
Surfaces shall not exceed 1:48 (2%) max slope in any
direction at accessible parking spaces and access
aisle. Violations Found: Exceeds 1:48 (2%) in parking
1 46 | P a g e
94 City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
and/or access aisles (Findings - 10.5% / 2.9% /
3.0%).
Accessible Stall
Striping
Item E.2,
Pg. 21 CBC 11B.502
Missing NO PARKING Stencil. Access Aisle less than
60" Minimum (5') measured centerline to centerline.
(Minor Violation). This area shall provide a VAN
Accessible parking space.
1 Parking Space 3: Section
4(C) Estimated Cost: See "Overall Parking" section.
Accessible Route Item A.3,
Pg. 23 CBC 11B-502.7 Slope violations to court / Findings - 3.1%. 1 Accessible Space
Identification
Item C.3,
Pg. 24
2013 CBC 11B502.6.
Missing "Minimum FINE $250" sign. This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to eliminate
the potential for litigation. Incorrect Sign.
1 Accessible
Parking Slope
Item D.3,
Pg. 25 CBC 11B-502.4 Violations Found: Exceeds 1:48 (2%) in parkingand/or access aisles (Findings - 3.4% / 4.1%). 1 Accessible Stall
Striping
Item E.3,
Pg. 25 CBC 11B.502 Missing NO PARKING Stencil. 1
Parking Space 4: Section
4(D) Estimated Cost: See "Overall Parking" section.
Accessible Route Item A.4,
Pg. 27 CBC 11B-502.7 Provided at corner curb ramp. Slope violation found. 1 Accessible Space
Identification
Item C.4,
Pg. 28
2013 CBC 11B502.6.
Missing "Minimum FINE $250" sign. This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to eliminate
the potential for litigation. Incorrect Sign.
1 Accessible
Parking Slope
Item D.4,
Pg. 29-30 CBC 11B-502.4
Violations Found: Exceeds 1:48 (2%) in parking
and/or access aisles (Findings - 14.6% / 4.0%).
Change in elevation exceeds 1/4" vertical and 1/4"
beveled. Deteriorated Surface - Maintenance
Required.
1 Accessible Stall
Striping
Item E.4,
Pg. 30 CBC 11B.502
Findings - 201" / Space and/or accessible parking
less than 216" (18') in length. Diagonal parking
spaces require longer parking spaces. Shall be per
city requirements.
1 Parking Space 5 &
6:
Section
4(E) Estimated Cost: See "Overall Parking" section.
Accessible Route Item A.5,
Pg. 32 CBC 11B-502.7 See "Accessible Route Exterior" Section. 1 Parking
Requirements
Item B.5,
Pg. 32
CBC 11B502.7.1 Forced to walk behind vehicle other than their own. 1 Accessible Space
Identification
Item C.5,
Pg. 33
2013 CBC 11B502.6.
Missing "Minimum FINE $250" sign. This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to eliminate
the potential for litigation. Incorrect Sign. Only (1) sign provided for (2) spaces.
1 Accessible
Parking Slope
Item D.5,
Pg. 34 CBC 11B-502.4 Violations Found: Exceeds 1:48 (2%) in parking and/or access aisles (Findings - 5.1% / 4.3%). 1 Accessible Stall
Striping
Item E.5,
Pg. 35 CBC 11B.502
Findings - 195" / Space and/or accessible parking
less than 216" (18') in length. Missing required access aisle.
1 Parking Space 7 &
8:
Section
4(F) Estimated Cost: See "Overall Parking" section.
Accessible Route Item A.6,
Pg. 36 CBC 11B-502.7 See "Accessible Route Exterior" Section. 1 Parking
Requirements
Item B.6,
Pg. 36
CBC 11B502.7.1 Forced to walk behind vehicle other than their own. 1 Accessible Space
Identification
Item C.6,
Pg. 37
2013 CBC 11B502.6.
Missing "Minimum FINE $250" sign. This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to eliminate
1 47 | P a g e
95 City of Hermosa Beach
Transition Plan
Violations: Community
Center and Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
the potential for litigation. Incorrect Sign. Only (1) sign provided for (2) spaces.
Accessible
Parking Slope
Item D.6,
Pg. 38 CBC 11B-502.4 Violations Found: Exceeds 1:48 (2%) in parkingand/or access aisles (Findings - 5.8% / 5.4%). 1 Accessible Stall
Striping
Item E.6,
Pg. 39 CBC 11B.502
Findings - 194" / Space and/or accessible parking
less than 216" (18') in length. Missing required
access
aisle.
1 Parking Space 9: Section
4(G) Estimated Cost: See "Overall Parking" section.
Accessible Route Item A.7,
Pg. 40 CBC 11B-502.7 See "Curb Ramp" Section. 1
Accessible Space
Identification
Item C.7,
Pg. 41
2013 CBC 11B502.6.
Missing "Minimum FINE $250" sign. This is not
considered a barrier under the ADA, however, it is
recommended to provide current signs to
eliminate
the potential for litigation. Incorrect Sign.
1 Accessible Parking
Slope
Item D.7,
Pg. 42 CBC 11B-502.4
Violations Found: Exceeds 1:48 (2%) in
parking and/or access aisles (Findings - 4.4% /
9.3%).
Excessive slope violations.
1 Accessible Stall
Striping
Item E.7,
Pg. 43 CBC 11B.502
Missing NO PARKING Stencil / Does not provide a
loading access aisle on the side of the vehicle.
Note: This layout is not in accordance with the State
of
California Standards in Chapter 11B.
1 Curb Ramps: Section 5 Cost Estimate: $3,500 $3,963.75 Slope and Cross
Slope
Item A,
Pg. 44-46
CBC 11B-406
/28
Curb Ramp shall have a slope of 1:12 (8.33%)
or less. Cross slope shall not exceed 1:48 (2%).
Location - At Parking Space 9 / Exceeds 1:12
(8.33%) on Ramp Portion / Findings - 8.8% ramp
slope & 5.5%cross slopes. Location: South side of
building at Parking Spaces 5/6 & 7/8 - Exceeds 1:12
(8.33%) on
Ramp Portion / Findings - 9.6%. Cross slope
violations, Exceeds 1:48 (2%) / Findings -
4.1%.
2 48” Opening on
Ramp
Item B,
Pg. 46-47
CBC 11B406.5.8
Curb ramp shall have a 48" minimum opening by
the full length of the ramp. Location: South side of
building at Parking Spaces 5/6 & 7/8 - Findings - Not
flush at same elevation at bottom of ramp.
2 Counter Slopes Item C,
Pg. 47-48 11B-406.5.8
Counter slopes of adjoining gutters and road
surfaces immediately adjacent to and within 24
inches of the curb ramp shall not be steeper than
1:20. Location -
At Parking Space 9 / Findings - 6.4% / Greater
than 5% within 24" of bottom of ramp.
2 Slope of Flared
Sides
Item D,
Pg. 48-49
CBC 11B406.2.2
Flared or fanned sides shall be 10% or less
slope. Location - At Parking Space 9 / Findings -
15.3 left
wing.
2 Detectable
Warnings
Item E,
Pg. 49-50
No Detectable Warning Devices provided / This is
not considered a "Barrier" in the ADA requirements.
Detectable warning Devices are not required in the
2010 ADA Standards for Accessible Design. Curb
ramp at Parking Space 9 - Not Provided. Curb
Ramp
at Parking Spaces 5/6 & 7/8 - Not provided.
2 Accessible Routes
Exterior: Section 6 Estimated Cost to connect an accessible route to the courtyard from the building with the Gymnasium. – $28,312.50 $25,000 for a ramp.
48 | P a g e
96 City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Walks Item A,
Pg. 51-57 11B-403
Provide compliant walks for accessible routes with
48" minimum width, 1:48 (2%) or less cross slopes &
1:20 (5%) or less running slopes. City sidewalk from
Parking Space 9 to an entrance / Cross Slopes
exceed 1:48 (2%) (Findings- 3.4%). Location - Access
to main theatre entrance / Cross Slopes exceed 1:48
(2%) (Findings- 4.9%). Location - Access to theatre
entrance from HWY 1 and Pier Ave. / Findings -
(6.6% / 5.7%) / Slopes exceed 1:20 (5%) and shall be
considered a "RAMP" (Landings and Handrailing
Required). Cross Slopes exceed 1:48 (2%) (Findings4.9%). Location - Access to theatre entrance from Pier Ave. / Findings - (5.8%) / Slopes exceed 1:20
(5%) and shall be considered a "RAMP" (Landings
and Handrailing Required). Location - Access to
theatre entrance from HWY 1 and 11th Pl / Findings -
(6.7% / 6.6% / 8.7%) / Slopes exceed 1:20 (5%) and
shall be considered a "RAMP" (Landings and
Handrailing Required). Location: South side of
building at Parking Spaces 5/6 & 7/8 - Findings - 5.5%
/ 5.0% Cross Slopes.
2 Accessible Route
of Travel
Item B,
Pg. 57-58 11B-206.2.2
Provide accessible route of travel to and from all
accessible buildings and within accessible facilities.
North Door to Building with Gymnasium - These doors
leads to stairs. Access between these doors and the
courtyard are required to connect the Theatre building
and main community center building. The main
building does not provide vertical access between
floors by the means of an elevator or ramp. This is an
existing building with only 2 levels and not required to provide an elevator in existing buildings. However, the city is required to provide access for programs
provided by the city. An elevator should be provided
to connect the lower and upper levels.
2 ISA Directional
Sign
Item C,
Pg. 59 11B-216.6
In existing buildings and facilities where not all
entrances comply with 11B-404 (Doors, Doorways,
and Gates), entrances complying with 11B-404
(Doors, Doorways, and Gates) shall be identified by
the International Symbol of Accessibility complying
with 11B-03.7.2.1. NOTE: Not all doors are required
to be accessible in existing buildings. It is
recommended to provide at least (1) accessible
entrance to the theatre and place ISA directional
signs directing people to the accessible entrance. It is recommended to modify as many doors as possible to
meet accessibility requirements.
2 Ramps: Section 7 Cost Estimate: $35,000 to modify or add railing and modify ramps. $39,637.50 Slope of Ramp Item A,
Pg. 60-62 CBC 11B-405
Slopes on ramp shall not exceed 1:12 (8.33%) and
maximum 1:48 (2%) cross slope. Exceeds 1:12
(8.33%) on Ramp Portion / Findings - 17.2% ramp
slope at bottom portion. NOTE: This ramp is part of
an egress from the Gymnasium and not required to
be accessible unless modified or altered. Exception
for existing buildings. Ramp inside main community
center building - Exceeds 1:12 (8.33%) on Ramp
Portion / Findings - 8.7% ramp slopes.
3 Required Level
Landings
Item B,
Pg.63-66 CBC 11B-405.7
Ramp landings shall provide landings with slopes not
exceeding 1:48 (2%) with top landings 60"x 60"
minimum. The existing entryway is considered a ramp
and shall meet all ramp requirements including
compliant landings. The existing configuration was
found to have landing violations as well as no
landings at 30" vertical intervals. It is recommended to provide a new accessible route that will join the
3 49 | P a g e
97 City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
existing at or near the door landing. Some modification are necessary at the door landing as well. This will be more cost effective than to remove the existing ramp,
redesign and rebuild. Location - Egress Ramp from
Gymnasium / Compliant landings not provided / 56" (72"
required). NOTE: This ramp is part of an egress from
the Gymnasium and not required to be accessible
unless modified or altered. Exception for existing
buildings. Ramp inside main community center building / Findings - 60" bottom landing. This does not violate
codes at the time of
construction.
Pedestrian
Ramps
Item C,
Pg. 67-68 CBC 11B405.8
Ramps shall provide hand railing on each side of ramp.
Findings - Some paths of travel with slopes exceeding
5% but not exceeding 8.33% do not have railing
required for an accessible route. If a compliant path of travel is provided then the remaining ramps will not
need to be modified. Not ALL paths of travel
are required to be compliant in existing buildings.
3 Railing Height Item D,
Pg. 68-69 CBC 11B505.4
Provide railing on both sides of ramp at 34"-38" to top of railing from ramp surface and consistent in height.
Existing hand railings do not meet accessible
requirements. Not all railings and ramps need to be
accessible as long as (1) accessible route to the Theatre is provided and marked with ISA directional
signs directing persons with disabilities.
3 Railing Extension Item E,
Pg. 69-
CBC
11B505.10
.1
Handrail shall extend a minimum of 12" beyond the top
landing and 12" at the bottom landing. Extension are
less than 12" parallel with landings and/or not extending over landings. (Minor Violation). Location - Egress
Ramp from Gymnasium / Extensions not parallel with
landings. NOTE: This ramp is part of an egress from the Gymnasium and not required to be accessible unless
modified or altered. Exception for
existing buildings.
3 Width between
Railing
Item F,
Pg. 71
2013 CBC
11B405.5
Ramps shall have a minimum clear width of 48". / Hand
rails shall be permitted to project 3-1/2" into clear width each side when railing is attached to wall surface /
ADAS less stringent. Findings - 33" wide clear. NOTE:
This ramp is part of an egress from the Gymnasium and
not required to be accessible unless
modified or altered. Exception for existing buildings.
3 Gripping Surface Item G,
Pg. 71 CBC 11B505.6
Handrails shall be configured so that the gripping surface is continuous along their length and they shall not be
obstructed along their tops or sides. Location - Egress Ramp from Gymnasium / Railing not smooth and
continuous. NOTE: This ramp is part of an egress from
the Gymnasium and not required to be accessible unless
modified or altered. Exception for
existing buildings.
3 Stairways: Section 8 Cost Estimate: $25,000 To modify or add railing and provide contrasting stripe. $28,312.50
Hand Railing Item B,
Pg. 72-73 11B-505.2
Handrails shall be provided on both sides of stairs and ramps. Location - Stairs at Parking Space 1 & 2 -
Findings - Railing provided on one side only.
4 Railing Extension Item C,
Pg. 74-78
CBC
11B505.10
.3
Modify handrail to extend a minimum of 12" beyond the
top nosing and 12" plus tread width, beyond the bottom
nosing. Findings - Less than 12" parallel with landing
surface. (Minor Violation). Findings - Does not extend a full tread width before it levels out for the landing
extension. (Minor Violation). (Typical
Findings)
4 Gripping Surface Item D,
Pg. 79 CBC 11B505.6
Handrails shall be configured so that the gripping surface is continuous along their length and they shall 4
50 | P a g e
98 City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code
Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
not be obstructed along their tops or sides. Findings - Not smooth and continuous.
Stair Stripes Item E,
Pg. 11B-504.4.1
Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast.
Exterior stairs shall have the upper approach and all
treads marked by a stripe providing clear visual contrast. - Findings - No contrasting striping
provided.
2 Entrance Door
Codes &
Requirements:
Section
9(A)
Estimated Cost: $5000 - This estimated cost is for adjustment of door closures only. It may be required to replace some closures to meet the $5,662.50 requirements for accessible doors. NOTE: All other estimated costs for individual doors will be noted in the individual sections of this part.
Entrance Door 1: Section
9(B) Cost Estimate: $5000 - Hardware & Maneuvering space. $5,662.50 Maneuvering
Space for
Forward
Approach
Item C.2,
Pg. 89-90 CBC 11B-404
The floor or ground space within the required
clearances shall be level and clear. Main Theatre
Doors - 3.1% in level maneuvering space.
2 Smooth Surface
at Bottom of Door
Item D.2,
Pg. 90
CBC
11B404.2
.10
Provide a 10" smooth panel on the push side of door or
gate. Findings - Door Stop in 10" smooth area.
Findings - Door hardware in 10" smooth area.
3 EXIT Sign Item E.2,
Pg. 91 CBC 11B-703 Provide tactile EXIT sign at exit doors in accordance with CBC 11B-703 Signs. Findings - Not Provided. 2 Entrance Door 2: Section
9(C) Cost Estimate: $2500 - To change out hardware. $2,831.25 ISA Decal Item A.3,
Pg. 93 CBC 11B216.6.
Required when not all doors are accessible. Findings
- Not Provided. 2
Door Closing
Speed
Item E.3,
Pg. 93
CBC
11B404.2
.8.1
Adjust or provide door closure so that from an opening
position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door. Findings
- 2-3 Seconds 90-12 all leafs.
2 Pull/Push Force Item G.3,
Pg. 93
CBC
11B404.2
.9
Modify door pull/push force to maximum of 5lbs of
pressure 30" from the hinge or the door hardware
whichever is furthest from the hinge. Findings -
Between 10lbs and 20lbs. Findings - Panic bar
exceeds 15lbs.
2 Smooth Surface
at Bottom of Door
Item L.3,
Pg. 93
CBC 11B404.2.10 Findings - Door hardware in 10" smooth area. 3 EXIT Sign Item M.3,
Pg. CBC 11B-703 Findings - Not provided. 2
Entrance Door 3: Section
9(D) Cost Estimate: $5000 - To Replace doors. $5,662.50 ISA Decal Item A.4,
Pg. 84 CBC 11B216.6.
Required when not all doors are accessible. Findings
- Not Provided. 3
Double Leaf
Doors
Item B.4,
Pg. 96 11B-404.2.2
At least one of the active leaves of doorways with two
leaves shall comply with 11B-404.2.3 No Compliant door
leaf provided. Violations stated in this section.
2 Accessible Door Item C.4,
Pg. 96 CBC 11B-404
Provide 32" clear width from face of door at 90deg to
opposite stop. Door 3' wide by 6'-8" shall be provided.
Findings - 30" wide clear / Less than 32" minimum
clear width.
2 Pull/Push Force Item G.4,
Pg. 96
CBC
11B404.2
.9
Doors evaluated were found to be in violation with this code. Verify all accessible doors meet this requirement.
Findings - 15lbs - 20lbs. / Panic
hardware greater than 15" to activate.
2 Smooth Surface
at Bottom of Door
Item L.4,
Pg. 97
CBC 11B404.2.10 Findings - Door hardware in 10" smooth area. 3 EXIT Sign Item M.4,
Pg. 97 CBC 11B-703 Findings - Not Provided. 2
Entrance Door 4: Section
9(E) Cost Estimate: $5000 - To Replace Doors. $5,662.50 ISA Decal Item A.5,
Pg. 84 CBC 11B216.6.
Findings - Not Provided. 3
51 | P a g e 99
City of Hermosa Beach
Transition Plan
Violations: Community
Center and Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Double Leaf
Doors
Item B.5,
Pg. 100 11B-404.2.2 No Compliant door leaf provided. Violations stated inthis section. 2 Accessible Door Item C.5,
Pg. 100 CBC 11B-404 Findings - 29" wide clear / Less than 32" minimumclear width. 2 Pull/Push Force Item G.5,
Pg. 100
CBC 11B404.2.9
Doors evaluated were found to be in violation with
this code. Verify all accessible doors meet this
requirement. Findings - 15lbs - 20lbs. / Panic
hardware greater than 15" to activate.
3 Smooth Surface at
Bottom of Door
Item L.5,
Pg. 100
CBC 11B404.2.10 Findings - Door hardware in 10" smooth area. 3 EXIT Sign Item M.5,
Pg. 101 CBC 11B-703 Findings - Not Provided. 2
Entrance Door 5: Section
9(F) Cost Estimate: $2,500 $2,831.25
ISA Decal Item A.6,
Pg. 84 CBC 11B-216.6. Findings - Not Provided. 3
Door Closing
Speed
Item B.6,
Pg. 102
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12. 3
Pull/Push Force Item C.6,
Pg. 102
CBC 11B404.2.9 Findings - 12lbs. 3
Threshold Item D.6,
Pg. 103
CBC 11B404.2.5
Provide or modify door threshold or raise
maneuvering space so that the floor or landing
shall not be more than 1/2" lower than the top of
the threshold of the doorway. Findings - 1-1/2" to
top of
threshold.
2 Smooth Surface
at Bottom of Door
Item E.6,
Pg. 103
CBC 11B404.2.10 Findings - Door Stop in 10" smooth area. 3 EXIT Sign Item F.6,
Pg. 104 CBC 11B-703 Findings - Not Provided. 2
Entrance Door 6: Section
9(G) Cost Estimate: $500 $566.25
ISA Decal Item A.7,
Pg. 84 CBC 11B-216.6. Findings - Not Provided. 3
Door Closing
Speed
Item B.7,
Pg. 105
CBC 11B404.2.8.1 Findings – 3-4 Seconds 90-12. 4
Pull/Push Force Item C.7,
Pg. 106
CBC 11B404.2.9 Findings - 10lbs both doors. 2
Smooth Surface
at Bottom of Door
Item D.7,
Pg. 106
CBC 11B404.2.10 Findings - Door Stop in 10" smooth area. 3 EXIT Sign Item E.7,
Pg. 107 CBC 11B-703 Findings - Not Provided. 2
Entrance Door 7: Section
9(H) Only if operated by staff only.
Pull/Push Force Item B.8,
Pg. 108
CBC 11B404.2.9 Findings - 12lbs each door. 2
Smooth Surface at
Bottom of Door
Item C.8,
Pg. 109
CBC 11B404.2.10Findings - Door Stop in 10" smooth area. Findings - Door hardware in 10" smooth area. 3
Entrance Door 8: Section
9(I) Cost Estimate: $2,500 $2,831.25
Door Closing
Speed
Item B.9,
Pg. 110
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12. 2
Pull/Push Force Item C.9,
Pg. 110
CBC 11B404.2.9 Findings - 10-12lbs. 2
Maneuvering Space
for Forward
Approach
Item D.9,
Pg. 111-
112
CBC 11B-404 2.3% in level maneuvering space (Minor). Change in elevation greater than 1/4" Vertical and 1/4"
beveled.
4 Smooth Surface at
Bottom of Door
Item E.9,
Pg. 113
CBC 11B404.2.10Findings - Door Stop in 10" smooth area. Findings - Door hardware in 10" smooth area. 3
EXIT Sign Item F.9,
Pg. 113 CBC 11B-703 Findings - Not Provided. 2
Exit Doors at Theatre
Stage:
Section
9(J) Cost Estimate: $3,000 $3,397.50
52 | P a g e
100
City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Door Closing
Speed
Item A.10,
Pg. 115
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12. 2
Pull/Push Force Item B.10,
Pg. 114
CBC 11B404.2.9 Findings - 8-10lbs. 3
Threshold Item C.10,
Pg. 114
CBC 11B404.2.5Findings - Door on West side / 1-3/4" to top of threshold. 2
Smooth Surface
at Bottom of Door
Item D.10,
Pg. 116
CBC 11B404.2.10Findings - Door Stop in 10" smooth area. Findings - Door hardware in 10" smooth area. 3
EXIT Sign Item E.10,
Pg. 117 CBC 11B-703 Findings - Not Provided. 2
Museum Entrance
&
Exit Doors:
Section
9(K) Cost Estimate: $2,500 $2,831.25
Door Closing
Speed
Item A.11,
Pg.118
CBC 11B404.2.8.1 Findings - 2 Seconds 90-12. 2
Pull/Push Force Item B.11,
Pg. 119
CBC 11B404.2.9 Findings - Greater than 5lbs at EXIT doors. 3 Maneuvering
Space for
Forward
Approach
Item C.11,
Pg. 119-
121
CBC 11B-404 7.0% in level maneuvering space. 10.8% in level maneuvering space. 2
Threshold Item D.11,
Pg. 122
CBC 11B404.2.5 Findings - 1-1/4" to top of threshold. 2 Smooth Surface
at Bottom of Door
Item E.11,
Pg. 123
CBC 11B404.2.10 Findings - Door hardware in 10" smooth area. 3 EXIT Sign Item F.11,
Pg. 124 CBC 11B-703 Findings - Not Provided. 2
Miscellaneous
Doors:
Section 10 Cost Estimate: $9,000 10,192.50
Permanent Room
Tactile ID Sign
Item A,
Pg. 126-
127
11B-703.4
Tactile Characters on signs shall be located 48 inches
minimum above the finish floor or ground surface,
measured from the baseline of the lowest Braille cells
and 60 inches maximum above the finish floor or
ground surface, measured from the baseline of the
highest line of raised characters. Findings - All tactile ID room signs are mounted too high.
4 Accessible Door
Item B,
Pg. 127-
129
CBC 11B-404
Findings - 31" clear both door leafs. Exit doors at gym 24-1/2" clear wide. Doors to administrative office that are NOT accessed by the general public. These
doors do not need to comply. Findings - Less than 32"
minimum clear width.
4 Door Hardware
Item C,
Pg. 130-
132
2013 CBC 11B404-2-7
Hardware shall be easy to grasp with one hand and
shall not be required to twist with the wrist, grasp
tightly or does not require tight pinching. Findings -
Twist Type door knob.
3 Door Closing
Speed
Item D,
Pg. 132
CBC 11B404.2.8.1
Doors evaluated were found to be in violation with this code. Verify all accessible doors meet this
requirement. Findings - Many doors closed faster than
5 seconds 90 degrees to 12 degrees from door latch.
3 Door Closure
Height
Item E,
Pg. 133-
134
CBC 11B404.2.3
Modify door closure to be a minimum of 78" clear
above finish floor or ground. Location: Several doors
in the building with the gymnasium - Door closures
are lower than the 78" minimum clear requirement.
Doors to administrative office that are occasionally
accessed by the general public. These doors shall
comply. Findings - 77".
4 Pull/Push Force Item F,
Pg. 134
CBC 11B404.2.9
Doors evaluated were found to be in violation with this code. Verify all accessible doors meet this
requirement. Findings - Most ALL doors in this facility were excessive in pressure and closure speeds. 10lbs
- 20lbs. / Panic hardware greater than 15" to activate. 2 Maneuvering
Space for
Forward
Approach
Item G,
Pg. 135-
136
CBC 11B-404 Double Doors in main building near interior ramp.
Findings - 2.6% in maneuvering space. 4
53 | P a g e
101
City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Vision Lights
Location
Item H,
Pg. 136-
137
11B-404.2.11
Doors, gates, and side lights adjacent to doors or
gates, containing one or more glazing panels that
permit viewing through the panels shall have the
bottom of at least one glazed panel located 43 inches
maximum above the finish floor. Double Doors to Gym
- 45" to vision lights on both doors. One required to be 43" AFF. Doors to administrative office that are NOT
accessed by the general public. These doors do
not need to comply. Findings - 44" to vision light.
4 EXIT Sign Item I, Pg.
138-140 CBC 11B-703 Findings - Not Provided. 4
Threshold Item J, Pg.
140-141
CBC 11B404.2.5Door 15 - Threshold greater than 1/4" vertical and 1/4" beveled. 3
Smooth Surface at
Bottom of Door
Item K,
Pg. 141-
145
CBC 11B404.2.10 Findings - Door Stop in 10" smooth area. Typical 4 Point of Sale
Counters:
Section 11 Cost Estimate: $6,000 $6,795.00
Sales or Service
Counter Height
Item A,
Pg. 146-
147
CBC 11B-904.4
Provide or modify sales or service counter to 28"
minimum to 34" maximum height and 36" minimum
long. Findings - Ticket counter for Theatre does not
provide a portion at 34" max high by 36" minimum
wide – This shall be accessible from both employee
side and public side. Bar service in theater lobby -
Findings - 42" to top of counter.
1 Service Counters: Section 12 Cost Estimate: $2000 - To drop counter. $2,265.00 Countertop Width
and Height
Item A,
Pg. CBC 11B-904.4 Administrative Office service counter -Findings - 34-1/2" to top from finish floor. 4 Accessible Routes
Interior: Section 13 Cost Estimate: $1000 - Add cane protection barrier to floor. $1,132.50 Path of Travel
Item A,
Pg. 149-
150
11B-307.2
Objects with leading edges more than 27 inches and
not more than 80 inches above the finish floor or
ground shall protrude 4 inches maximum horizontally
into the circulation path. Overhead hazard at stairwell at west side of building.
2 Reach Ranges for
Operable Parts: Section 14 Cost Estimate: $100 $113.25
Reach Range
Requirements
Item A,
Pg. 151-
11B-308.2
Where a forward reach is unobstructed, the high
forward reach shall be 48 inches maximum and the
low forward reach shall be 15 inches minimum above
the finish floor or ground. Public information items - At least one of each kind shall be within reach range.
3 Men's Restroom
Door -
Main Building:
Section
15(A) Cost Estimate: $100 $113.25
Proper Signs
Item A.1,
Pg. 153-
154
11B-216.8
Doorways leading to toilet rooms and bathing rooms
complying with 11B- 603 (Toilet and Bathing Rooms)
shall be identified by a geometric symbol complying
with 11B- 703.7.2.6 (Toilet and Bathing Facilities
Geometric Symbols). Tactile Sign Not Provided.
1 Pull/Push Force Item B.1,
Pg. 154
CBC 11B404.2.9 Findings - 10lbs. 2
Women's
Restroom Doors
- Main Building:
Section
15(B) Cost Estimate: $50 $56.63
Proper Signs
Item A.2,
Pg. 155-
156
11B-216.8 Tactile Sign Not Provided. 1
Men's Restroom
Door -
Upper Level:
Section
15(C) Cost Estimate: $250 $283.13
Proper Signs
Item A.3,
Pg. 157-
158
11B-216.8
Findings - Incorrect mounting. Tactile sign mounted
on door and door sign mounted where the tactile sign
is to be mounted. Incorrect mounting height.
1 Pull/Push Force Item B.3,
Pg. 158
CBC 11B404.2.9 Findings - 15lbs. 2
54 | P a g e
102
City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Smooth Surface
at Bottom of Door
Item C.3,
Pg. 158
CBC 11B404.2.10 Findings - Door Stop in 10" smooth area. 3 Women's Restroom
Door - Upper Level:
Section
15(D) Cost Estimate: $250 $283.13
Proper Signs
Item A.4,
Pg. 160-
161
11B-216.8
Findings - Incorrect mounting. Tactile sign mounted
on door and door sign mounted where the tactile sign
is to be mounted. Incorrect mounting height.
1 Pull/Push Force Item B.4,
Pg. 161
CBC 11B404.2.9 Findings - 15lbs. 2
Smooth Surface
at Bottom of Door
Item C.4,
Pg. 162
CBC 11B404.2.10 Findings - Door Stop in 10" smooth area. 3 Men's Restroom
DoorGymnasium
Building:
Section
15(E) Cost Estimate: $250 $283.13
Door Closing
Speed
Item A.5,
Pg. 163
CBC 11B404.2.8.1 Findings - 3 Seconds 90-12. 3
Pull/Push Force Item B.5,
Pg. 163
CBC 11B404.2.9 Findings - 10lbs. 3
Women's Restroom
Door –
Gymnasium
Building:
Section
15(F) Cost Estimate: $250 $283.13
Proper Signs
Item A.6,
Pg. 164-
165
11B-216.8 Geometric sign on door not provided. 1
Pull/Push Force Item B.6,
Pg. 165
CBC 11B404.2.9 Findings - 8lbs. 3
Men's Restroom -
Main
Building:
Section
16(A) Cost Estimate: $6,000 - to provide ambulatory compartment $6,795.00 and other misc. corrections.
Clearance at
Water Closet
Item A.1,
Pg. 167 11B-604.3
Clearances around water closets and in toilet
compartments shall comply with 11B-604.3. Findings
- 59-1/4" clear wide (Minor Violation).
3 Toilet Stall Doors Item B.1,
Pg. 168 CBC 1133B.2
Provide 32" clear width from face of door at 90deg to
opposite stop. Findings - 26-1/2 wide clear / Door to
required ambulatory compartment shall be 32" clear
width.
1 Ambulatory
Compartment
Handrails
Item C.1,
Pg. 169 11B-213.3.1
Where toilet compartments are provided, at least one
toilet compartment shall comply with 11B-604.8.1.
Findings - Not Provided / 6 or more fixtures provided.
(1) Shall be ambulatory.
2 Ambulatory
Compartment
Location
Item D.1,
Pg. 170 CBC 11B-604.2 Findings - 58-1/2" deep / Less than 60" deep by 39" wide. 4 Water Closet in
Ambulatory
Compartment
Location
Item E.1,
Pg. 171 CBC 11B-604.2
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or partition.
Findings - 20" from side wall.
3 Side Grab Bar
Location
Item F.1,
Pg. 172 11B-604.5.1
The side wall grab bar shall be 42 inches long
minimum, located 12 inches maximum. From the rear
wall and extending 54 inches minimum from the rear
wall with the front end positioned 24 inches minimum
in front of the water closet. Findings - Not mounted
54" minimum from rear wall.
4 Water Closet Seat
Cover Height
Item G.1,
Pg. 173
CBC
1115B.4.1.4
Install water closet with a seat height of 17" - 19"
above finish floor. Findings - 16-1/2" - Change seat
cover.
2 Restroom
Accessories
Item H.1,
Pg. 174 CBC 11B-603.5.
Relocate (or provide same) restroom accessories to a
height of 40" maximum to highest operable parts
above finish floor. Findings - (42" for Towel
Dispenser).
3 Women's
Restroom -
Main Building:
Section
16(B) Cost Estimate: $200 $226.50
Self-Closing Door Item A.2,
Pg. 175 11B-404.2.7
The door shall be self-closing. A door pull complying
with 11B-404.2.7 (Door and Gate Hardware) shall be
placed on both sides of the door near the latch with a
3 55 | P a g e 103
City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
1.5 second minimum closing time from 70 deg (2010
ADA 404.2.8.2 Spring Hinges). Findings - Not
self- closing.
Water Closet Seat
Cover Height
Item B.2,
Pg. 176
CBC
1115B.4.1.4 Findings - 16-1/2" AFF / Change seat cover. 2 Men's Restroom -
Upper
Level:
Section
16(C) Cost Estimate: $15,000 $16,987.50
Self-Closing Door Item A.3,
Pg. 178 11B-404.2.7 Compartment door not provided. 2
Compartment
Door Location
Item B.3,
Pg. 178 11B-604.8.1.2
Doors shall be located in the front partition or in the side wall or partition furthest from the water closet.
Finding - Toilet not placed diagonally from
compartment door.
2 Clearance at
Water Closet
Item C.3,
Pg. 179 11B-604.3
Clearances around water closets and in toilet
compartments shall comply with 11B-604.3. Findings
- 56-1/2" wide (60" minimum required).
2 Grab Bars
Location
Item D.3,
Pg. 180 CBC 11B-609.4
Grab bars shall be positioned 33" min to 36" max
measured from top of bar to the floor. Findings - 37-
1/2" to top on rear bar.
2 Side Grab Bar
Location
Item E.3,
Pg. 181 11B-604.5.1
The side wall grab bar shall be 42 inches long
minimum, located 12 inches maximum from the rear
wall and extending 54 inches minimum from the rear
wall with the front end positioned 24 inches minimum
in front of the water closet. Provide 1-1/2" inch
minimum clearance. Findings - 36" long bar / No 1-
1/2" minimum clearance.
2 Rear Wall Grab
Bar
Item F.3,
Pg. 182
CBC 11B604.5.2
Grab Bars shall be 36" long and mounted 33" to 36"
measured to the top of the grab bar. Clearance above
the tank shall be 1-12" minimum to bottom of grab
bar. Bar shall be position above water closet at 12"
and 24". Findings - 30" long bar.
2 Water Closet
Location
Item G.3,
Pg. 183 CBC 11B-604.2
The centerline of the water closet fixture shall be
centered 17" to 18" from the side wall or partition.
Findings - 16" from side wall.
1 Sink Location Item H.3,
Pg. 184 CBC 11B-606
All lavatories that are designated to be accessible
shall be a minimum of 17" in horizontal depth and
mounted with the rim or counter edge no higher than
34" above finish floor with a vertical clearance
measured from the bottom of the apron or the outside
bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. Findings -
34-1/2" to top of counter from finish floor.
3 Exposed Pipes Item I.3,
Pg. 185
CBC
1115B.4.3.4
Provide insulated wrapping around pipes under sink.
Findings - Exposed. 1
Restroom
Accessories
Item J.3,
Pg. 186 CBC 11B-603.5.
Relocate (or provide same) restroom accessories to a
height of 40" maximum to highest operable parts
above finish floor. Findings - (49" Soap Dispenser),
(42" for Towel Dispenser).
2 Lever on Urinal Item K.3,
Pg. 187 11B-605.4
Flush controls shall be hand operated or automatic.
Hand operated flush controls shall comply with 11B309 (Operable Parts) except that the flush control shall be mounted at a maximum height of 44 inches
above the finish floor. Findings - 45" to top of lever. 4 Women's Restroom
-
Upper Level:
Section
16(D) Cost Estimate: $15,000 $16,987.50
Compartment
Door Handles
Item A.4,
Pg. 189
CBC 11B-404-2-
7 Provide door hardware mounted between 34" and 44"
above finish floor. Hardware shall be easy to grasp
with one hand and shall not be required to twist with
the wrist, grasp tightly or does not require tight
pinching. Findings - Not Provided on inside of door.
1 Self-Closing Door Item B.4,
Pg. 189 11B-404.2.7 Findings - Not self-closing. 2
56 | P a g e
104
City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation Date:
Recommendations:
Compartment
Door Location
Item C.4,
Pg. 190 11B-604.8.1.2 Findings - Not positioned diagonally from watercloset. 2 Clearance at
Water Closet
Item D.4,
Pg. 191 11B-604.3 Findings - 57-1/2" wide. 3
Grab Bars
Location
Item E.4,
Pg. 192 CBC 11B-609.4 Findings - 37-1/2" to top of bar on rear bar. 2 Side Grab Bar
Location
Item F.4,
Pg. 192 11B-604.5.1 Findings - 36" long / 1-1/2" clearance not provided /Bar greater than 12" from rear wall. 2 Rear Wall Grab
Bar
Item G.4,
Pg. 194
CBC 11B604.5.2 Findings - 30" long. 3
Water Closet
Location
Item H.4,
Pg. 195 CBC 11B-604.2 Findings - 15-1/2" from side wall. 2 Flushing Lever
Location
Item I.4,
Pg. 195 CBC 11B-604.6
Install toilet with the control on the open side of the water closet. Control shall be operable with one hand
and shall not require tight grasping, pinching or
twisting. Control shall be on the wide side of the toilet area and mounted no more than 44" above the finish
floor. The force to activate controls shall be no greater that 5lbs. force. Findings- short side of stall.
2 Toilet Tissue
Dispenser
Location
Item J.4,
Pg. 196 11B-604.7
Toilet paper dispensers shall comply with 11B-309.4
(Operation) and shall be 7 inches minimum and 9
inches maximum in front of the water closet measured
to the centerline of the dispenser. Findings - Not
positioned correctly.
2 Sink Location Item K.4,
Pg. 197 CBC 11B-606 Findings - 34-1/2" to top of counter. 3 Exposed Pipes Item L.4,
Pg. 198
CBC
1115B.4.3.4 Findings - Exposed. 1
Restroom
Accessories
Item M.4,
Pg. 199 CBC 11B-603.5. Findings - (42" Soap Dispenser), (42" for TowelDispenser). 3 Coat Hook Height Item N.4,
Pg. 200 11B-604.8.3
Coat hooks shall be located within one of the reach
ranges specified in 11B-308 (Reach Ranges).
Shelves shall be located 40 inches minimum and 48
inches maximum above the finish floor. Findings - 58"
to top of hook. Provide (1) at 48" max.
2 Men's Restroom -
Gymnasium
Building:
Section
16(E) Cost Estimate: $3000 - Provide 36" clear width at urinal. $3,397.50 Accessible Urinal
Floor Space
Item A.5,
Pg. 202-
203
CBC 11B-305
Provide required clear floor space. Where urinals are
provided, at least one shall have a clear floor space
30" by 48" in front of the urinal to allow forward
approach. In alcoves greater than 24", an additional
6" shall be required. Findings - Less than 36"
minimum wide with an alcove greater than 24".
3 Group A
Occupancies -
Assembly Halls,
Auditoriums,
Theaters:
Section 17 Estimated cost for renovation to provide program accessibility to this facility is not possible estimate due to the scope of modifications required.
Assistive-listening
Systems
Item A,
Pg. 206 11B-219
Assistive listening systems shall be provided in
accordance with 11B-219 and shall comply with 11B706 (Assistive Listening Systems). Findings - Not Provided.
1 Receivers
Provided
Item B,
Pg. 207 11B-219.3
The minimum number of receivers to be provided
shall be equal to 4 percent of the total number of
seats, but in no case less than two. Twenty-five
percent minimum of receivers provided, but no fewer
than two, shall be hearing-aid compatible in
accordance with 11B-706.3
1 Listening System Item C,
Pg. 207 11B-219.4
If the assistive listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the stage or
playing area and shall have a complete view of the
stage or playing area.
1 57 | P a g e
105
City of Hermosa Beach
Transition Plan
Violations:
Community
Center and
Theatre
Pg. Ref.,
Item
Number
Code Reference
Comments: Priority
(1-4)
UPDATED
ESTIMATED
COST
Implementation
Date: Recommendations:
Permanent
Systems
Item D,
Pg. 207 11B-219.5
Permanently installed assistive listening systems are
required in areas if (1) they accommodate at least 50
persons or if they have audio-amplification systems,
and (2) they have fixed seating. If portable assistive
listening systems are used for conference or meeting
rooms, the system may serve more than one room.
An adequate number of electrical outlets or other
supplementary wiring necessary to support a portable
assistive listening system shall be provided.
1 Signage Item E,
Pg. 207
A sign shall be posted in a prominent place indicating
the availability of assistive listening devices. Locations and types shall include the International Symbol of
Access for Hearing Loss complying with figure 11B14C and indicating wording that states "Assistive Listening System Available".
1 Assembly Area
Accessible
Spaces
Item F,
Pg. 208 11B-221.1
Assembly areas shall provide wheelchair spaces,
companion seats, designated aisle seats and semiambulant seats complying with 11B-221 (Assembly Areas) and 11B- 802 (Wheelchair Spaces,
Companion Seats, and Designated Aisle Seats). In
addition, lawn seating shall comply with 11B- 221.5
(Lawn Seating). Findings - No designated aisle seats
and semi-ambulant seats.
2 Accessible
Seating
Item H,
Pg. 208 11B-221.2.1.1
Findings - No dispersion of accessible seating and
companion seats provided. There shall be (7) total
accessible seating and companion seats provided.
2 Accessible Seats Item I, Pg.
209-210 11B-221.2.3
Wheelchair spaces shall provide lines of sight
complying with 11B-802.2 (Lines of Sight) and shall
comply with 11B-221.2.3. Findings - Accessible
seating and companion seating not provided in
dispersed areas and viewing locations.
2 Designated Aisle
Seats
Item J, Pg.
210 11B-221.4
At least 5 percent of the total number of aisle seats
provided shall comply with 11B-802.4 (Designated
Aisle Seats) and shall be the aisle seats located
closest to accessible routes. Findings - Removable
armrest and ISA identification not provided.
2 Accessible Route
to Stage
Item K,
Pg. 211
CBC
11B206.2.4
At least one accessible route shall connect accessible
building or facility with all accessible spaces and
elements within a building or facility which are
otherwise connected by a circulation path unless
exempted by 206.2.3. Findings - Not Provided.
3 Accessible
Seating Areas
Item L, Pg.
212 11B-802.1
Wheelchair spaces shall comply with 11B-802.1.
Findings - Not Provided. Findings - Slopes greater
than 1:12 (8.33%) are present in the existing aisles.
This area can satisfy partial dispersement.
3 Drinking Fountains: Section 18 Cost Estimate: $5,000 $5,662.50 Minimum Number
of Fountains
Item B,
Pg. 214
28 CFR Part 36
ADAAG 4.15
ADA 602.1 -
602.6
Where drinking fountains are provided, no fewer than
two shall be provided and shall comply with 28 CFR
Part 36 ADAAG 4.15 ADA 602.1 - 602.6 (Clear Floor
Space, Operable Parts, Spout Height, Spout Location,
Water Flow) and one for Standing Persons ADA
602.7 (Drinking fountains for Standing Persons.)
4 Fountain Location Item B,
Pg. 215 CBC 11B-602
Drinking fountains shall be located in an alcove,
between wing walls, or positioned not to project into
the accessible route more than 4". Alcoves may be
railing protection but may not be greater than 6:
above finish floor. Findings - No Alcove provided.
4 Stage Areas: Section 19 Cost Estimate: $25,000 - For a chair lift. $28,312.50 Accessible Stage Item A,
Pg. 216
CBC
11B206.2.4
At least one accessible route shall connect accessible
building or facility with all accessible spaces and
elements within a building or facility which are
otherwise connected by a circulation path unless
exempted by 206.2.3
3 58 | P a g e
106
City of Hermosa Beach
Transition Plan
C. Transition Plan
1. Facilities
a) Barrier Removal Priorities
b) Prioritizing Access
c) Priorities for Barrier Removal within Facilities
d) Transition Plan for Facilities
e) Phasing Schedule for Facilities
D. Pedestrian Rights-of-Way (PROW)
1. Surveys of Existing PROW Conditions
2. Pedestrian Rights-of-Way Prioritization
3. Time Period for Pedestrian Rights-of-Way Improvements
4. PROW Construction Details
5. Accessibility during construction
6. Street or Sidewalk Closure
7. On-Street Accessible Parking
8. Citizen Request Process
59 | P a g e
107
Appendix B – ADA Evaluation Reports
A.1 Parking Structure (ADA Plus LLC)
108
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
13th Street - Parking Structure
Hermosa Beach CA 90254
Inspection Date: 3/18/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
109
Date: 3/18/2015 Report ID: Parking
Structure_H.B.001
Property:
13th Street - Parking Structure
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 2 of 46110
IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
PROGRAM ACCESSIBILITY for Title II Facilities.
General. A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
ADA.gov - Public entity. A public entity covered by title II is defined as -- 1) Any State or local government;
2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include -- 1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees;
3) Whether the entity receives significant assistance from the government by provision of property or equipment; and
4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
Relationship to title III. Public entities are not subject to title III of the ADA, which covers only private entities.
Conversely, private entities are not subject to title II. In many situations, however, public entities have a close relationship to private entities that are covered by title III, with the result that certain activities may be at least indirectly affected by both titles.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 3 of 46111
California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
Building Use:
Parking Structure
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 4 of 46112
Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Site Arrival Points.....................................................6 2 Overall Parking ........................................................8 3(A) Parking Codes and Requirements ....................11 3(B) Level 3 - Parking Spaces ..................................17 3(C) Level 2 - Parking Spaces..................................24 3(D) Upper Level / Hermosa Ave Entrance/Exit .......30
4 Curb Ramps...........................................................36 5 Accessible Routes Exterior....................................38 6 Elevator..................................................................43 Agreement ................................................................46 ADA Inspection Plus, LLC
13th Street - Parking Structure Page 5 of 46113
1. Site Arrival Points
C N/C Yes No I N/I A/R N/A A
A.
At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking spaces, passenger loading zones, if provided, and public streets and sidewalks.
•
B. Detectable warning devices shall be at walks crossing vehicular ways. • C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking, and accessible passenger loading zones, and public streets or sidewalks. Provide accessible route of travel to and from all accessible buildings and accessible facilities. CBC 11B-206 / 28 CFR Part 36 App. A -
4.3 / ADA 2010 Standards: 206 Accessible Route.
Findings - See "Accessible Routes Exterior" Section
A. East Access - From Hermosa Ave. (Cross Slopes violations) ADA Inspection Plus, LLC
13th Street - Parking Structure Page 6 of 46114
A. West Access form Beach (Cross Slope / Curb Ramp violations) B. Detectable warning devices shall be provided (36" minimum width) at hazardous vehicular areas per CBC only.
The Color shall be yellow conforming to FS 33538 of Federal Standard 959C CBC 11B-705.1.2.5 / ADA 2010 Standards: Only at boarding platforms currently)
Verify with the Authorizing Agency to determine requirements with regards to the vehicular way as a "Hazardous Vehicular Area" meeting a pedestrian way.
This is not a "Barrier" with the ADA requirements.
C.
Estimated Costs: $5000 - For detectable warning devises only.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 7 of 46115
2. Overall Parking
The parking structure is split into two sections with dedicated entrance / exit for each area.
Vehicular and Pedestrian access for the Upper Level parking (2 & 3) is accessed from Hermosa Ave.
Vehicular access for the Lower Level (1) is through the ally on the north side of the facility.
Pedestrian access is through the S/W corner of the facility (Site Arrival Point).
Accessible Parking is provided in the Upper Levels 2 & 3 portion of the structure only with no accessible parking provided at the Lower Level (1) which has direct access to the street level on the S/W corner of the facility.
Accessible Parking is also provided on the East side (Attached to Upper Level Portion) near the Hermosa Ave.
Entrance / Exit. More severe violations found at this location.
It is recommended to provide accessible parking at the Lower Level Parking area.
See this section for more information.
C N/C Yes No I N/I A/R N/A A
A.
Sufficient accessible parking spaces with respect to the total number of reported spaces.
•
B. Sufficient number of van-accessible parking spaces. • C. "Unauthorized Vehicle Tow Away" Sign •
D.
Vertical clearance of 98" at accessible parking and at least one vehicle route from site entrance and exits.
•
E. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
13th Street - Parking Structure Page 8 of 46116
Comments:
A. 11B-208.1 General. Where parking spaces are provided, parking spaces shall be provided in accordance with 11B-208.
11B-208.2 Minimum Number. Parking spaces complying with 11B-502 (Parking Spaces) shall be provided in accordance with Table 11B-208.2 except as required by 11B-208.2.1 (Hospital Outpatient Facilities) 11B-208.2.2 (Rehabilitation Facilities and Outpatient Physical Therapy Facilities )and 11B-208.2.3 (Rehabilitation Facilities and Outpatient Physical Therapy Facilities) Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking facility.
TOTAL OVERALL PARKING SPACES PROVIDED =
Lower Level (97) / (No Accessible Parking)
Upper Levels (260) / (10 of 260) Marked Accessible
B. Six or a fraction of six parking spaces shall be VAN ACCESSIBLE. ADA 2010 Standards: 208.2.4 Van Parking Spaces / One in every eight accessible spaces (for Safe Harbor), but not less than one, shall be van accessible with the access isle on the passenger side of the parking space. CBC 11B-208.2.4 Van Spaces.
Findings - No Van Accessible Parking Provided
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 9 of 46117
C. Provide a new "Unauthorized Vehicle Tow Away" (R100B) sign with the proper information with a minimum 17"x22" with 1" lettering at each site entrance or in view of each accessible space. Sign shall read" UNAUTHORIZED
VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS
OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE...TOWED VEHICLES MAY BE CLAIMED AT....OR BY TELEPHONING... CBC 11B-502.8 Findings - Not Provided / Provide one at each driveway entrance.
E.
Estimated Cost: $500 - Signs Only.
See "Parking Spaces" section for estimated cost for parking.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 10 of 46118
3(A) . Parking Codes and Requirements
Information Only
C N/C Yes No I N/I A/R N/A A
A.1.
An accessible route must be provided from accessible parking to an accessible entrance.
•
B.1.
Wheel Stop or curb to prevent vehicles from walking surface. Shortest possible route. Not forced to walk behind spaces other than the persons own space.
•
C.1.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
D.1.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
E.1. Accessible stall striping. •
F.1.
Path of Travel shall have no obstacles that protrude more than 4 inches into walkways or corridors between 27" AFF and 80" AFF
•
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.1. Parking shall connect to the shortest possible accessible route to the accessible entrance/s. CBC 11B-502.7 / 28 CFR Part 36 App A - 4.6.2 Location. / ADA 2010 Standards: 208.3 Location B.1. A bumper or curb must to placed to prevent encroachment of cars. The spaces must be located so a person with a disability is not compelled to wheel or walk behind parking spaces other than that person's own space. CBC 11B-502.7.1 / 28 CFR Part 36 App. A: 4.6 / ADA 2010 Standards: 502.7 Relationship to Accessible Routes. (ADA does not require arrangement to NOT walk behind vehicles other than their own.) ADA Inspection Plus, LLC
13th Street - Parking Structure Page 11 of 46119
C.1. Signs shall be provided at spaces for each parking stall space for persons with disabilities. Signs shall be identified by a reflective sign no less than 70 square inches with a white ISA on blue background and additional language below the symbol of accessibility stating "Minimum Fine $250". Van spaces must have a sign reading "Van Accessible" Bottom of sign must be mounted Minimum 80" above finish elevation in areas of pedestrian access. 60" Min. above finish elevation if centered on a wall. 2013 CBC 11B-502.6. / 28 CFR Part 36 App A: 4.6.4 / ADA 2010 Standards: 502.6 Identification.
D.1. Surfaces shall not exceed 1:48 (2%) max slope in any direction at accessible parking spaces and access aisle.
CBC 11B-502.4 / 28 CFR Part 36 App. A - 4.6 / ADA 2010 Standards: 502.4 Floor and Ground Surfaces. Changes in level are not permitted.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 12 of 46120
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 13 of 46121
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 14 of 46122
E.1. Stripe accessible parking space with 36"x36" ISA (White on Blue), 216" (18') long 108" (9') wide with blue boarder measured centerline to centerline. White 12" "NO PARKING" in access aisle. Diagonal lines in access aisle ADA Inspection Plus, LLC
13th Street - Parking Structure Page 15 of 46123
at 36" O.C. Access aisle shall be 60" (5') wide for standard accessible stall. A van space width shall be 144" with a 60" wide access aisle. Exception: permitted to be 108" min wide when the access aisle is 96" (8') wide min. Van access aisle shall be on the passenger side of vehicle. CBC 11B.502 Parking Spaces. / 28 CFR Part 36 App A: 4.6.3 Parking Spaces (Modified Layout) / ADA 2010 Standards: 502 Parking Spaces.(Modified Layout) F.1. 11B-307.2 Protrusion Limits. Objects with leading edges more than 27 inches and not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path. / 28 CFR Part 36 App A: 4.4 Protruding Objects / ADA 2010 Standards: 307 Protruding Objects 11B-307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum and 80 inches maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches, the lowest edge of such sign or obstruction shall be 27 inches maximum or 80 inches minimum above the finish floor or ground.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 16 of 46124
3(B) . Level 3 - Parking Spaces
The Upper Level 3 Parking provides charging stations for able body drivers. Provide at least (1) charging station in a position to where a disabled driver and an able body person can access.
No Van Accessible Parking Provided on Level 3
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 17 of 46125
C N/C Yes No I N/I A/R N/A A
A.2.
Wheel Stop or curb to prevent vehicles from walking surface. Shortest possible route. Not forced to walk behind spaces other than the persons own space.
•
B.2.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
C.2.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
D.2. Accessible stall striping. •
E.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
13th Street - Parking Structure Page 18 of 46126
Comments:
A.2.
Provide Wheel Stop at PS 3.2 to prevent encroachment on accessible route B.2. Findings - 40" +/- all 3 signs / Mounting height of 60" min from ground surface to bottom of sign not provided.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 19 of 46127
B.2. Missing "Minimum FINE $250" sign - Typical all signs on level 3 ADA Inspection Plus, LLC
13th Street - Parking Structure Page 20 of 46128
D.2.
Parking Space 3.1
Findings - 202" / Space and/or accessible parking less than 216" (18') in length. (Minor Violation)
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 21 of 46129
D.2.
Parking Spaces 3.1, 3.2 & 3.3
Findings - 88" +/- to centerline - Striping not measured 108" centerline to centerline.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 22 of 46130
D.2. Parking Spaces 3.1, 3.2 & 3.3
Missing NO PARKING Stencil
E.2.
Estimated Cost: $9,000 - Charging station, Striping and Signage.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 23 of 46131
3(C) . Level 2 - Parking Spaces
No Van Accessible Parking Provided on Level 2
C N/C Yes No I N/I A/R N/A A
A.3.
Wheel Stop or curb to prevent vehicles from walking surface. Shortest possible route. Not forced to walk behind spaces other than the persons own space.
•
B.3.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
C.3.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
D.3. Accessible stall striping. •
E.3.
Path of Travel shall have no obstacles that protrude more than 4 inches into walkways or corridors between 27" AFF and 80" AFF
•
F.3. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
13th Street - Parking Structure Page 24 of 46132
Comments:
A.3.
Provide Wheel Stop to prevent encroachment into accessible route.
B.3. Findings - 40" - 55" +/- all 3 signs on level 2 / Mounting height of 60" min from ground surface to bottom of sign not provided.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 25 of 46133
B.3.
Missing "Minimum FINE $250" sign - Typical all (3) signs on Level 2 C.3. Surfaces shall not exceed 1:48 (2%) max slope in any direction at accessible parking spaces and access aisle.
CBC 11B-502.4 / 28 CFR Part 36 App. A - 4.6 / ADA 2010 Standards: 502.4 Floor and Ground Surfaces. Changes in level are not permitted.
Findings - 2.7% in Access Aisle
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 26 of 46134
D.3.
Findings - 88" +/- / Striping not measured 108" centerline to centerline.
See Level 3 Parking Spaces for requirements.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 27 of 46135
E.3. 11B-307.2 Protrusion Limits. Objects with leading edges more than 27 inches and not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path. / 28 CFR Part 36 App A: 4.4 Protruding Objects / ADA 2010 Standards: 307 Protruding Objects 11B-307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum and 80 inches maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches, the lowest edge of such sign or obstruction shall be 27 inches maximum or 80 inches minimum above the finish floor or ground.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 28 of 46136
E.3.
Provide Cane Protection under stairwell beam.
F.3.
Estimated Cost: $4000 - Slope modifications, Striping, Cane Protection & Signage.
Estimated Cost: $1500 - To add at least (2) accessible parking spaces on the lower level parking.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 29 of 46137
3(D) . Upper Level / Hermosa Ave Entrance/Exit
No Van Accessible Parking Provided on Upper Level at Hermosa Ave Entrance / Exit No Access Aisles Provided
A Van Accessible Parking Space is placed behind a fenced area. It may be better to relocate the fence for storage to the existing accessible parking area and provide additional accessible parking at fenced area.
Design may be required to meet full compliance.
C N/C Yes No I N/I A/R N/A A
A.4.
Wheel Stop or curb to prevent vehicles from walking surface. Shortest possible route. Not forced to walk behind spaces other than the persons own space.
•
B.4.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
C.4.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
D.4. Accessible stall striping. •
E.4. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.4. A bumper or curb must to placed to prevent encroachment of cars. The spaces must be located so a person with a disability is not compelled to wheel or walk behind parking spaces other than that person's own space. CBC 11B-502.7.1 / 28 CFR Part 36 App. A: 4.6 / ADA 2010 Standards: 502.7 Relationship to Accessible Routes. (ADA does not require arrangement to NOT walk behind vehicles other than their own.) ADA Inspection Plus, LLC
13th Street - Parking Structure Page 30 of 46138
A.4. Forced to walk behind vehicle other than their own. California Building Code Only ADA Inspection Plus, LLC
13th Street - Parking Structure Page 31 of 46139
B.4.
Findings - 36" / Mounting height of 60" min from ground surface to bottom of sign not provided & Incorrect Sign.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 32 of 46140
C.4.
Violations Found: Exceeds 1:48 (2%) in parking and/or access aisles (Findings - 2.4% / 3.0% / 3.5% / ) ADA Inspection Plus, LLC
13th Street - Parking Structure Page 33 of 46141
D.4.
Findings - 96" / Striping not measured 108" centerline to centerline.
D.4.
Findings - Lines not painted BLUE. Typical all (4) spaces.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 34 of 46142
D.4.
Findings - No Access Aisles provided
E.4.
Estimated Costs: $7000 - Design, striping, signs & slope modifications ADA Inspection Plus, LLC
13th Street - Parking Structure Page 35 of 46143
4. Curb Ramps
C N/C Yes No I N/I A/R N/A A
A. Slope shall not exceed 8.33% (1:12) or 2% cross slope (1:48) • B. Detectable warnings shall be 36"deep by width of curb ramp. • C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Curb Ramp shall have a slope of 1:12 (8.33%) or less. Cross slope shall not exceed 1:48 (2%). CBC 11B-406 / 28 CFR Pt36 App A 4.3.7 Slope / 2010 ADA 406
A. Construction of this curb ramp does not allow for a complaint path of travel when entering the ramp from the north side. Design shall provide cross slopes no greater than 1:48 (2%) entering the ramp.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 36 of 46144
B. Detectable warning surfaces 36" minimum deep by full width of curb ramp shall be provided. Placement shall be 6" Min to 8" Max. from bottom of ramp. CBC 11B-406.5.12 (11B-705) / Currently not required in 2010 ADA Standards for accessible Design.
(This is not considered a "Barrier" in the ADA requirements as Detectable Warning Devices are not required on curb ramps.)
Findings - No Detectable Warning Devices provided See "Accessible Routes Exterior" section.
C.
Estimated Cost: $5000 - For North curb ramp approach from top.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 37 of 46145
5. Accessible Routes Exterior
C N/C Yes No I N/I A/R N/A A
A. Walks (48" wide minimum and 2% max cross slope) ( 5% max running slope) • B.
Changes in level shall not exceed 1/4" vertical and 1/4" beveled at 45 degrees with a 1/2" maximum overall.
•
C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide compliant walks for accessible routes with 48" minimum width, 1:48 (2%) or less cross slopes & 1:20 (5%) or less running slopes. 11B-403 Walking Surfaces / 28 CFR Part 36 App. A - 4.3 / ADA 2010 Standards: 403 Walking Surfaces (Less Restrictive)
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 38 of 46146
A.
Findings 2.7% cross slope / Level 1 - Elevator to West Site Access Point for beach access.
A. Findings 3.4% cross slope / Level 1 - Parking marked route to West Site Access Point curb ramp for beach access.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 39 of 46147
A. Findings - 10.0% in the direction of travel / From Marked Accessible Parking to Hermosa Ave in Structure.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 40 of 46148
A. Findings - 3.5% cross slope / From Hermosa Ave to Structure.
B. Changes in level up to 1/4" may be vertical and without edge treatment. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than one unit vertical in 2 units horizontal (50% slope) Changes in level greater 1/2" shall be accomplished by means of a curb ramp, ramp, elevator or platform lift.... CBC 11B-303 Changes in Level. / 28 CFR Part 36 App. A - 4.3.8 Changes in level. / ADA 2010 Standards: 303 Changes in Level. / Levels exceeding 4" shall be identified by a 6" high curb or hand railing - Warning Curbs 11B-303.5 Findings -
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 41 of 46149
B. Findings - 1" change in elevation at sidewalk join / Level 1 - Parking marked route to West Site Access Point curb ramp for beach access.
C.
Estimated Cost: $3000 - Replace concrete.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 42 of 46150
6. Elevator
C N/C Yes No I N/I A/R N/A A
A. Elevator Door Landings and Clear floor Space at Call Controls • B.
Elevator hoist-way shall be provided and markings shall be mounted 48" min to bottom of Braille and 60" maximum to bottom of highest tactile wording. •
C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
13th Street - Parking Structure Page 43 of 46151
Comments:
A. 11B-407.2 Elevator Landing Requirements. Elevator landings shall comply with 11B-407.2. 11B-407.2.1.3 Clear Floor or Ground Space. A clear floor or ground space complying with 11B-305 (Clear Floor or Ground Space) shall be provided at call controls.
Findings - Level 3 elevator approach 3.9%
B. 11B-407.2.3.1 Floor Designation. Floor designations complying with 11B-703.2 (Signs -Raised Characters) and 11B-703.4.1 (Height Above Finish Floor or Ground) shall be provided on both jambs of elevator hoist-way entrances.
Floor designations shall be provided in both raised characters and braille. Raised characters shall be 2 inches high minimum. A raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry level. The outside diameter of the star shall be 2 inches and all points shall be of equal length. Raised characters, including the star, shall be white on a black background. Braille complying with Section 11B- 703.3 (Braille) shall be placed below the corresponding raised characters and the star. The Braille translation for the star shall be “MAIN”.
Applied plates are acceptable if they are permanently fixed to the jamb. / 2010 ADA Standards 407.2.3.1 Floor Designation
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 44 of 46152
B. Findings - Not Provided on first floor jams. These shall have a STAR to identify the "Main" floor.
C.
Estimated Cost: $2500 - For Landing and Door jam identification.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 45 of 46153
Evaluation Statement
This ADA Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at 13th Street - Parking Structure, Hermosa Beach, CA 90254. This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply.
ADA Inspection Plus, LLC
13th Street - Parking Structure Page 46 of 46154
Appendix B – ADA Evaluation Reports
A.2 Clark Building (ADA Plus LLC)
155
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
Clark Building - 861 Valley Dr.
Hermosa Beach CA 90254
Inspection Date: 3/18/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
156
Date: 3/18/2015 Report ID: Clark Building
H.B.002
Property:
Clark Building - 861 Valley Dr.
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 2 of 92157
IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
PROGRAM ACCESSIBILITY for Title II Facilities.
General. A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
ADA.gov - Public entity. A public entity covered by title II is defined as -- 1) Any State or local government;
2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include -- 1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees;
3) Whether the entity receives significant assistance from the government by provision of property or equipment; and
4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
Relationship to title III. Public entities are not subject to title III of the ADA, which covers only private entities.
Conversely, private entities are not subject to title II. In many situations, however, public entities have a close relationship to private entities that are covered by title III, with the result that certain activities may be at least indirectly affected by both titles.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 3 of 92158
California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
Building Use:
Banquet and Party Facility for Public Use
Age Of building:
Pre ADA Regulations, Year Built - 1939
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 4 of 92159
Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Site Arrival Points.....................................................6 2 Overall Parking ........................................................7 3 Parking Spaces......................................................10 4 Curb Ramps...........................................................24 5 Accessible Routes Exterior....................................27 6 Ramps....................................................................32 7 Stairways ...............................................................36 8 Entrance Doors......................................................39 9(A) Meeting Room Door..........................................44 9(B) Kitchen Door .....................................................47 10 Dining and Work Surfaces ...................................49 11 Accessible Routes Interior ...................................51 12 Reach Ranges for Operable Parts.......................53 13 Kitchens & Kitchenettes.......................................56 14 Restroom Doors...................................................59 15(A) Women's Restroom.........................................70 15(B) Men's Restroom ..............................................83 16 Stage Areas .........................................................90 Agreement ................................................................92 ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 5 of 92160
1. Site Arrival Points
C N/C Yes No I N/I A/R N/A A
A.
At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking spaces, passenger loading zones, if provided, and public streets and sidewalks.
•
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking, and accessible passenger loading zones, and public streets or sidewalks. Provide accessible route of travel to and from all accessible buildings and accessible facilities. CBC 11B-206 / 28 CFR Part 36 App. A -
4.3 / ADA 2010 Standards: 206 Accessible Route.
Findings - See "Curb Ramps" Section for violations found and estimated costs.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 6 of 92161
2. Overall Parking
Public parking provided across the street from this facility and to the south on the west side of the street. The count for provided parking includes the entire length of street parking which may also serve other city facilities including tennis courts and softball fields.
The evaluation and recommendations are for this entire parking - excluding City Vehicles Only parking spaces.
The Existing conditions provide (4) accessible parking spaces for the overall 90 provide spaces.
Recommendation: It may be possible to add an access aisle and a new car accessible space adjacent to the existing across the street and provide only (1) accessible parking on the west side of the street. However, if a space is added at this location, then a 48" wide accessible route shall be provided in front of the parking to prevent forcing a person with disabilities to pass behind a vehicle other than their own.
C N/C Yes No I N/I A/R N/A A
A.
Sufficient accessible parking spaces with respect to the total number of reported spaces.
•
B. Sufficient number of van-accessible parking spaces. • C. "Unauthorized Vehicle Tow Away" Sign •
D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 7 of 92162
Comments:
A. 11B-208.1 General. Where parking spaces are provided, parking spaces shall be provided in accordance with 11B-208. / ADAS 2010 208
11B-208.2 Minimum Number. Parking spaces complying with 11B-502 (Parking Spaces) shall be provided in accordance with Table 11B-208.2 except as required by 11B-208.2.1 (Hospital Outpatient Facilities) 11B-208.2.2 (Rehabilitation Facilities and Outpatient Physical Therapy Facilities )and 11B-208.2.3 (Rehabilitation Facilities and Outpatient Physical Therapy Facilities) Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking facility.
TOTAL OVERALL PARKING SPACES PROVIDED = 90
TOTAL ACCESSIBLE PARKING SPACES PROVIDED = 4
TOTAL REQUIRED ACCESSIBLE PARKING SPACES = 4
C. Provide a new "Unauthorized Vehicle Tow Away" (R100B) sign with the proper information with a minimum 17"x22" with 1" lettering at each site entrance or in view of each accessible space. Sign shall read" UNAUTHORIZED
VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS
OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE...TOWED VEHICLES MAY BE CLAIMED AT....OR BY TELEPHONING... CBC 11B-502.8 ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 8 of 92163
C.
Findings - Outdated wording and missing required information.
D.
Estimated Cost: $500 for signs only - Place in clear view of all accessible parking. (One on each side of the road.)
See "Parking Spaces" section for estimated costs for Parking.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 9 of 92164
3. Parking Spaces
C N/C Yes No I N/I A/R N/A A
A.
An accessible route must be provided from accessible parking to an accessible entrance.
•
B.
Wheel Stop or curb to prevent vehicles from walking surface. Shortest possible route. Not forced to walk behind spaces other than the persons own space. •
C.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
D.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
E. Accessible stall striping. •
F. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 10 of 92165
Comments:
A. Parking shall connect to the shortest possible accessible route to the accessible entrance/s. CBC 11B-502.7 / 28 CFR Part 36 App A - 4.6.2 Location. / ADA 2010 Standards: 208.3 Location Findings - See "Accessible Routes Exterior" and "Curb Ramps" Sections for violations found.
B. A bumper or curb must be placed to prevent encroachment of cars. The spaces must be located so a person with a disability is not compelled to wheel or walk behind parking spaces other than that person's own space. CBC 11B-502.7.1 / 28 CFR Part 36 App. A: 4.6 / ADA 2010 Standards: 502.7 Relationship to Accessible Routes. (ADA does not require arrangement to NOT walk behind vehicles other than their own.) ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 11 of 92166
B.
Forced to walk behind vehicle other than their own. It appears to be possible to move the parking spaces out and provide an accessible route in front of the existing parking spaces.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 12 of 92167
C. Signs shall be provided at spaces for each parking stall space for persons with disabilities. Signs shall be identified by a reflective sign no less than 70 square inches with a white ISA on blue background and additional language below the symbol of accessibility stating "Minimum Fine $250". Van spaces must have a sign reading "Van Accessible" Bottom of sign must be mounted Minimum 80" above finish elevation in areas of pedestrian access. 60" Min. above finish elevation if centered on a wall. 2013 CBC 11B-502.6. / 28 CFR Part 36 App A: 4.6.4 / ADA 2010 Standards: 502.6 Identification.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 13 of 92168
C. Findings - 33" & 40" to bottom / 80" min clear to bottom of sign not provided at walking surface. This area can be considered a walking area.
Incorrect Signs
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 14 of 92169
C. Findings - 60" min clear to bottom of sign not provided.
Incorrect Signs
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 15 of 92170
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 16 of 92171
D. Surfaces shall not exceed 1:48 (2%) max slope in any direction at accessible parking spaces and access aisle.
CBC 11B-502.4 / 28 CFR Part 36 App. A - 4.6 / ADA 2010 Standards: 502.4 Floor and Ground Surfaces. Changes in level are not permitted.
Findings - 3.6%, 2.5% at PS 1 / 4.5%, 4.0% in access aisle / 2.8%, 4.0% PS 2 ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 17 of 92172
D.
Violations Found: Exceeds 1:48 (2%) in parking and/or access aisles (Findings - 2.7%) ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 18 of 92173
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 19 of 92174
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 20 of 92175
E. Stripe accessible parking space with 36"x36" ISA (White on Blue), 216" (18') long 108" (9') wide with blue boarder measured centerline to centerline. White 12" "NO PARKING" in access aisle. Diagonal lines in access aisle at 36" ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 21 of 92176
O.C. Access aisle shall be 60" (5') wide for standard accessible stall. A van space width shall be 144" with a 60" wide access aisle. Exception: permitted to be 108" min wide when the access aisle is 96" (8') wide min. Van access aisle shall be on the passenger side of vehicle. CBC 11B.502 Parking Spaces. / 28 CFR Part 36 App A: 4.6.3 Parking Spaces (Modified Layout) / ADA 2010 Standards: 502 Parking Spaces.(Modified Layout) E. Striping not measured centerline to centerline. (Minor Violation) ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 22 of 92177
E. Missing NO PARKING Stencil
Van Access Aisle less than 96" Minimum (8') measured centerline to centerline. (Minor Violation) F.
Estimated Cost: $6000
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 23 of 92178
4. Curb Ramps
This curb ramp layout is incorrect for the existing condition. A T-shaped curb ramp design with a level landing 60" by 60" recommended.
C N/C Yes No I N/I A/R N/A A
A. Slope shall not exceed 8.33% (1:12) or 2% cross slope (1:48) • B. Bottom turning space on parallel curb ramps shall not exceed 1:48 (2%) • C. Detectable warnings shall be 36"deep by width of curb ramp. • D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Curb Ramp shall have a slope of 1:12 (8.33%) or less. Cross slope shall not exceed 1:48 (2%). CBC 11B-406 / 28 CFR Pt36 App A 4.3.7 Slope / 2010 ADA 406
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 24 of 92179
A.
Exceeds 1:12 (8.33%) on Ramp Portion / Findings - 21.1% / Excessive A.
Cross pedestrian traffic parallel to the street creates a cross slopes of 21%. This is a very dangerous condition.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 25 of 92180
B. 11B-406.3.2 Turning Space. A turning space 48 inches minimum by 48 inches minimum shall be provided at the bottom of the Curb Ramp. The slope of the turning space in all directions shall be 1:48 maximum. / 2010 ADAS 406.3.2
Findings - Recommended modified layout
C.
No Detectable Warning Devices provided / This is not considered a "Barrier" in the ADA requirements.
Detectable warning Devices are not required in the 2010 ADA Standards for Accessible Design.
D.
Estimated Cost: $5000 - New curb ramp required.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 26 of 92181
5. Accessible Routes Exterior
C N/C Yes No I N/I A/R N/A A
A. Walks (48" wide minimum and 2% max cross slope) ( 5% max running slope) • B.
Accessible routes of travel shall be provided between buildings and within accessible facilities.
•
C.
Changes in level shall not exceed 1/4" vertical and 1/4" beveled at 45 degrees with a 1/2" maximum overall.
•
D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide compliant walks for accessible routes with 48" minimum width, 1:48 (2%) or less cross slopes & 1:20 (5%) or less running slopes. 11B-403 Walking Surfaces / 28 CFR Part 36 App. A - 4.3 / ADA 2010 Standards: 403 Walking Surfaces (Less Restrictive)
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 27 of 92182
A.
Slopes exceed 1:20 (5%) and shall be considered a "RAMP" (Landings and Handrailing Required) This is technically not a violation of the ADA Standards for Accessible Design.
The ADA allows slopes up to 1:12 (8.33%) with a 6" maximum rise and 6' maximum in length. California only allows this at door landings.
Minor violation of the CA building code. Cities may exempt this in roads if applicable.
B. Provide accessible route of travel to and from all accessible buildings and within accessible facilities. CBC - 11B-206.2.2 / 28 CFR Part 36 App. A - 4.3 / ADA 2010 Standards: 206 Accessible Route.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 28 of 92183
B.
Findings - This facility is connected to Clark Field and shall provide access to Clark Field C. Changes in level up to 1/4" may be vertical and without edge treatment. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than one unit vertical in 2 units horizontal (50% slope) Changes in level greater 1/2" shall be accomplished by means of a curb ramp, ramp, elevator or platform lift.... CBC 11B-303 Changes in Level. / 28 CFR Part 36 App. A - 4.3.8 Changes in level. / ADA 2010 Standards: 303 Changes in Level. / Levels exceeding 4" shall be identified by a 6" high curb or hand railing - Warning Curbs 11B-303.5 ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 29 of 92184
C.
Findings - 1" at top of ramp / Greater than 1/4" Vert / 1/4" beveled ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 30 of 92185
C.
1-1/2" vertical change in elevation - Not on an accessible route - hazardous condition for pedestrian ways D.
Estimated Cost: $6500 for new ramp with landings & railings.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 31 of 92186
6. Ramps
Design and construction of new ramp required to provide access to an accessible entrance.
Recommendation: Design to 5% maximum slopes in the direction of travel and 2% maximum cross slopes.
C N/C Yes No I N/I A/R N/A A
A.
Slope of ramp shall not exceed 1:12 (8.33%) running slope and 1:48 (2%) cross slope.
•
B. Required level landings shall be provided (60"x60" Top / 60"x72" Bottom). • C. Pedestrian ramps shall have compliant railings on both sides of ramp. • D.
Width between railings shall be at least 48 inches (less 3-1/2" each side when mounted on wall).
•
E.
Handrail size shall be 1-1/4" - 2" Outside Diameter. Non-circular handrail perimeter 4"-6-1/4"
•
F.
A curb 2" high minimum or a barrier preventing a 4" diameter sphere from passing through.
•
G. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 32 of 92187
Comments:
A. Slopes on ramp shall not exceed 1:12 (8.33%) and maximum 1:48 (2%) cross slope. CBC 11B-405 Slope - / 28 CFR Part 36 App. A - 4.8 Ramps / ADA 2010 Standards: 405 Ramps Findings - 8.5% - 11.2% ramp slopes
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 33 of 92188
B. Ramp landings shall provide landings with slopes not exceeding 1:48 (2%) with top landings 60"x 60" minimum.
Intermediate landings width of ramp x 60". Bottom landings width of ramp x 72". Changes in directions require landing 72" long x 60" wide with the 72" in the direction of downward travel. CBC 11B-405.7 / 28 CFR Part 36 App. A - 4.8 Ramps. / ADA 2010 Standards: 405 Ramps
C. Ramps shall provide hand railing on each side of ramp.. CBC 11B-405.8 Handrails for Ramps / 28 CFR Part 36 App. A - 4.8.5 / ADA 2010 Standards: 405.8 Handrails
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 34 of 92189
G.
Estimated Cost: $7500 if Ramp design / $4500 for 5% max walk with 6" curb edge protection.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 35 of 92190
7. Stairways
C N/C Yes No I N/I A/R N/A A
A. Existing Stairs Requirements - Pre-ADA regulations. • B. Risers shall be no less than 4" or greater than 7". • C. Hand Railings required on each side of stairs. •
D. Stairs have a stripe on the treads (1" from nose, 2"-4" stripe the width of tread) • E. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Interior and exterior stairs connecting levels that are not connected by an elevator, ramp or other accessible means of vertical access shall comply with 4.9 Stairs. 4.1.3 (4) In existing buildings that have different levels connected by an accessible route (ramp, elevator, etc.), no accessibility modifications are required to the stairs connecting levels that are connected by the elevator as long as the elevator is made accessible.
If the stairs are altered in any way, then the handrails have to comply at a minimum. 4.1.6 (d) B. 11B-504.2 Treads and Risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches high minimum and 7 inches high maximum. Treads shall be 11 inches deep minimum. 11B-504.3 Open Risers. Open risers are not permitted.. 2010 ADA Standards - 504.2 Treads and Risers Findings - Bottom riser is less than 4" / All rises are not equal.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 36 of 92191
C. 11B-505.2 Where Required. Handrails shall be provided on both sides of stairs and ramps./ 2010 ADA Standards 504 Stairways, 504.6 Handrails.
Findings - No Hand railing provided - Ramp is recommended to be provided at this location as well.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 37 of 92192
D. 11B-504.4.1 Contrasting Stripe. Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast. Exterior stairs shall have the upper approach and all treads marked by a stripe providing clear visual contrast. The stripe shall be a minimum of 2 inches wide to a maximum of 4 inches wide placed parallel to, and not more than 1 inch from, the nose of the step or upper approach. The stripe shall extend the full width of the step or upper approach and shall be of material that is at least as slip resistant as the other treads of the stair. A painted stripe shall be acceptable. Grooves shall not be used to satisfy this requirement.
Findings - It is recommended to provide contrasting stripe.
E.
Estimated Cost: $3000 for railing and contrasting stripe.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 38 of 92193
8. Entrance Doors
Modifications to this pair of door shall include a level maneuvering space. Design of a new entry may be required.
Recommendation: Place level (2% Max) landing at 72" from the face of door and provide a walk leading both directions at 5% maximum in the direction of travel. Provide a hand rail along the curb portion of landing area.
Minor door adjustments required for pressure and closure speeds.
C N/C Yes No I N/I A/R N/A A
A.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
B.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
C.
Maneuvering space for forward approach shall be 60" measured from the face of the closed door on the pull side. 48" from push side. Slopes shall not exceed 2% for Manual Doors
•
D. Threshold - 1/4" or 1/2" beveled at 1:2 between 1/4" and 1/2" • E.
An EXIT sign with Contracted Grade II Braille shall be placed on the strike side of the interior spaces leading to an accessible Exit.
•
F. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Adjust or provide door closure so that from an opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door.CBC 11B-404.2.8.1 / 28 CFR Part 36 App. A - 4.13.10 / 2010 ADAS-404.2.8.1 / Spring hinges are 70deg to closed position in 1.5 seconds minimum) Findings - 3 Seconds 90-12
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 39 of 92194
B. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware whichever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
Findings - Push bars are allowed 15lbs to release the door. It should be 5lbs after the release of the push bar.
The pressure exceeds 5lbs on the left door leaf. The ADA has no requirements for "Exterior Doors" ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 40 of 92195
C. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 41 of 92196
C.
8.8% ramp in level maneuvering space.
D. Provide or modify door threshold or raise maneuvering space so that the floor or landing shall not be more than 1/2" lower than the top of the threshold of the doorway. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2. CBC 11B-404.2.5 Thresholds / 28 CFR Part 36 App A: 4.13.8 Thresholds at doorways /ADA 2010 Standards: 404.2.5 Thresholds
Information Only
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 42 of 92197
E. Provide tactile EXIT sign at exit doors in accordance with CBC 11B-703 Signs / ADA 2010 Standards: 216.4 Means of Egress / No provisions in 28 CFR Pt 36 App A.
Findings - Not provided
Exit sign at all doors with illuminated EXIT signs.
"EXIT STAIRS DOWN" at doors leading to steps.
F.
Estimated Cost: $3500 for door landing and door adjustments ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 43 of 92198
9(A) . Meeting Room Door
Meeting Room Door / Applicable if used by the public. This door was locked and not inspected. - The door handle is a violation. Verify compliance with this section.
C N/C Yes No I N/I A/R N/A A
A.1. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • B.1.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.1.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
• •
D.1.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
• •
E.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 44 of 92199
Comments:
B.1. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob on meeting room door
B.1. Exit door in kitchen has a twist door knob as well. This door technically does not need to be accessible, however, it is recommended to provide a lever type door handle.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 45 of 92200
B.1. Closet door has a twist door knob. It is recommended to provide a lever type door handle.
E.1.
Estimated Cost $200
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 46 of 92201
9(B) . Kitchen Door
C N/C Yes No I N/I A/R N/A A
A.2.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
B.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.2. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 47 of 92202
B.2.
Estimated Cost: $250
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 48 of 92203
10. Dining and Work Surfaces
Information if applicable
C N/C Yes No I N/I A/R N/A A
A. Accessible seating shall be 5% of total seating in each functional area. • B.
Clear floor space for forward approach to tables and work surfaces shall be 30"x48" with 30" min clear to accessible route from behind or 48" clear backed by a wall or obstruction.
•
C.
Table and counter height for persons in a wheelchair 28" minimum to 34"maximum with proper knee clearance of 27" and a minimum width of 30" clear.
•
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide one wheelchair seating space for each 20 seats, with at least one minimum wheelchair seating space per each functional area. Accessible seating spaces shall be integrated with general seating to allow a reasonable selection of seating area to avoid having one area specifically highlighted as the area for persons with disabilities.
CBC 11B-226 Seating / 28 CFR Part 36 App A 4.32 Fixed or Built-in Seating and Tables / 2010 ADA Standards 226 Dining Surfaces and Work Surfaces
B. Provide a clear floor space for forward reach to tables and work surfaces and provide a 30" min clear space from the front edge of table to circulation path. CBC 1122B Fixed or Built-in Seating, Tables and Counters / CBC 1118B.4 Clear floor or ground space for wheelchairs. / 28 CFR Part 36 App A 4.2.4 Clear floor or ground space for wheelchairs / 2010 ADA Standards 305 Clear Floor or Ground Space & 226 Dining Surfaces and Work Surfaces ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 49 of 92204
C. Provide a table with a knee space of at least 27" high, 30" wide and 19" deep (CBC11B-306). Table or counter height shall be 28" min and 34" max above finish floor. (CBC 11B-902.3) / 28 CFR Part 36 App A 4.32.2 Knee Clearance / 2010 ADA Standards 306 & 902
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 50 of 92205
11. Accessible Routes Interior
C N/C Yes No I N/I A/R N/A A
A.
Path of Travel shall have no obstacles (phones, fountains, etc.) that protrude more than 4 inches into walkways or corridors between 27" AFF and 80" AFF •
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-307.2 Protrusion Limits. Objects with leading edges more than 27 inches and not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path. / 28 CFR Part 36 App A: 4.4 Protruding Objects / ADA 2010 Standards: 307 Protruding Objects 11B-307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum and 80 inches maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches, the lowest edge of such sign or obstruction shall be 27 inches maximum or 80 inches minimum above the finish floor or ground.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 51 of 92206
A. Findings - Greater than 4" from Wall / More than 27" from floor.
Recommendation: Relocate to adjacent wall and lower to 48" reach range.
B.
Estimated Cost: $250 - Relocate fire extinguisher cabinet.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 52 of 92207
12. Reach Ranges for Operable Parts.
C N/C Yes No I N/I A/R N/A A
A. Reach Range Requirements. •
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 53 of 92208
Comments:
A. 11B-308.2 Forward Reach.
11B-308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward reach shall be 15 inches minimum above the finish floor or ground. 11B-308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches maximum where the reach depth is 20 inches maximum. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum.
11B-308.3 Side Reach.
11B-308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches maximum and the low side reach shall be 15 inches minimum above the finish floor or ground.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 54 of 92209
A.
Does not meet "Safe Harbor" Requirements of 54" to top if installed before March 15, 2012.
Lower thermostat to 48" to top of control.
B.
Estimated Cost: $250
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 55 of 92210
13. Kitchens & Kitchenettes
If this kitchen is use by the general public, Then it shall be accessible.
C N/C Yes No I N/I A/R N/A A
A. Sinks provided shall have required knee clearance. • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-212.3 Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 11B- 606 (Lavatories and Sinks). EXCEPTION: 1. Mop service or scullery sinks shall not be required to comply with 11B-212.3.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 56 of 92211
A. Provide knee clearance at lavatory. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-603 / 28 CFR Part 36 App "A" 4.19 / 2010 ADAS 603 ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 57 of 92212
A.
Existing sinks do not meet compliance with at least (1) sink at 34" high AFF and required knee clearance.
B.
Estimated Cost: $1500 for new accessible sink
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 58 of 92213
14. Restroom Doors
This Women's Restroom door and access into the restroom has many severe violations. Complete design of restroom and doorway is necessary to provide an accessible entrance.
The Men's restroom door is not as severe but violations were still present and reconfiguration required.
C N/C Yes No I N/I A/R N/A A
A.
Women's sanitary facility - proper signs (1/4" thick, 12" circle / light on dark or dark on light)
•
B.
Men's sanitary facility - proper signs (1/4" thick, 12" equilateral triangle / light on dark or dark on light) Permanent Room Identification Sign (Braille) •
C.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
D. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • E. 5 seconds from 90deg to 12deg from latch. •
F.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
G.
Maneuvering space of 60" measured from the face of the closed door on the pull side. 48" from push side.
•
H.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
I. Door closure height of 78" minimum clear from finish floor. • J. Smooth surface 10" at the bottom of door on the push side. • K. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 59 of 92214
Comments:
A. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 60 of 92215
A.
Tactile Sign Not Provided / Geometric sign not provided B.
Tactile Sign Not Provided / Geometric sign not provided C. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 61 of 92216
C.
Women's Restroom and Men's Restroom door have twist type door knobs - Replace with lever type door handles.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 62 of 92217
D. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - Both restroom doors are less the 32" minimum clear ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 63 of 92218
D. Women's interior pass through - 31-1/2" clear / 78" clear D. Men's interior pass through - 27" clear / 78" clear
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 64 of 92219
E.
No Closure Provided
F.
No Closure Provided
G. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 65 of 92220
G. Women's Restroom Door - 35" on the pull side of door.
G. Men's Restroom door less than 18" strike side clearance on pull side of door. / 10" Findings ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 66 of 92221
H. 11B-404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate./ 28 CFR Part 36 App. A - 4.13 / ADA 2010 Standards: 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 67 of 92222
H. Findings - 11" recessed door at Men's restroom. - Door has latch and closure and 12" at less than 8" is required
I. Modify door closure to be a minimum of 78" clear above finish floor or ground. CBC 11B-404.2.3 / ADA 2010 Standards: 404.2.3 Clear Width - Exception 2.
Findings - Both restroom doors in violation
J. Provide a 10" smooth panel on the push side of door or gate. Cap all voids at top of smooth panel if void is present. CBC 11B-404.2.10 / ADA 2010 Standards: 404.2.10 Door and Gate Surfaces (Exception 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor shall not be required to provide smooth surfaces complying with 404.2.10 provided that if added kick plates are installed, cavities created by the kick plates are capped.)
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 68 of 92223
J. Both door have stop mounted in the smooth 10" area. Remove door stops K.
Estimated Cost: $4000 - New doors and reconfigure.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 69 of 92224
15(A) . Women's Restroom
No accessible compartment provided in this restroom. This entire restroom needs to be redesigned to meet current accessibility requirements.
See this section for codes and requirements for accessible restrooms.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 70 of 92225
C N/C Yes No I N/I A/R N/A A
A.1.
Public toilet rooms shall be large enough to accommodate a wheelchair turnaround (60" diameter) or have the required clear floor space. •
B.1. Required clearance at water closet shall be provided. • C.1. Stall door handles •
D.1.
Toilet stall doors shall be at least 32" wide on end doors or 34" on side doors to stalls.
•
E.1. Grab Bars shall be provided. •
F.1.
Side grab bar shall be min. 42" long 12 " max from back wall and 54" min from back wall.
•
G.1.
Rear wall grab bar shall be 36" long min. / 12" min center on one side and 24" min other side of water closet.
•
H.1. Grab bars shall carry a 250lbs. load min. •
I.1. Water closet shall be centered 17" to 18" center from side wall. • J.1. Water closet seat cover shall be 17"-19" above finish floor. • K.1.
Flushing lever on the wide side of stall with 5lbs maximum pressure to activate.
•
L.1. Sinks provided shall have required knee clearance. • M.1.
Sinks shall be mounted 34" max from top of rim above finish floor and 17" min from rear wall to front of sink.
•
N.1.
Faucet controls shall be operable with one hand without grasping, pinching or twisting with 5lbs max force to activate.
•
O.1. Sinks shall be mounted 18" minimum off the side wall to center of sink. • P.1. Exposed pipes under sinks shall be sufficiently insulated against contact. • Q.1. Mirror shall be 40" max above finish floor if provided. • R.1.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
S.1.
Toilet tissue dispenser shall be within 7" minimum to 9" to the center of dispenser maximum from the front of water closet and 14" minimum to 19" maximum from the floor to the outlet of the dispenser.
•
T.1. Coat Hooks shall be 48" maximum to the top of the hook. • U.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 71 of 92226
Comments:
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 72 of 92227
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 73 of 92228
B.1. 11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 11B-604.3.11B-604.3.1 Size. Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. A minimum 60 inches wide and 48 inches deep maneuvering space shall be provided in front of the water closet. ADDAG 91 - In existing facilities a clear floor space shall not be less than 36" by 48" in front of the water closet. In new facilities (CBC 1984), the wide clear floor space shall be 28" min to any fixture from the edge of the water closet and 32" clear to a wall or partition. In the 91 ADAAG a fixture can be 36" from the side wall. The width from wall to wall shall be 60" minimum.
Findings - No accessible compartment provided. This entire restroom needs to be redesigned to meet current accessibility requirements.
B.1. Existing compartments - Non Compliant.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 74 of 92229
C.1. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
U-Shaped handle shall be provided on front and back of compartment doors D.1. Provide 32" clear width from face of door at 90deg to opposite stop. CBC 1133B.2 Doors / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates / 34" when located on the side of the water closet compartment. CBC 1115B.3.1.4(4.4) 18" strike side clearance shall be 18" on out swings door and 12" on in swings doors. (2010 ADA 604.8.1.2)
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 75 of 92230
E.1. Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Clearance above the tank shall be 1-12" minimum to bottom of grab bar. Bar shall be position above water closet at 12" and 24". 2013 CBC 11B-604.5.2 / 28 CFR Part 36 App. "A" - 4.16.4 Grab Bars / ADA 2010 Standards: 604.5 Grab Bars. Exception: 2010 ADA Standards - 604.5.2 Exception 1 the rear grab bar shall be permitted to be 24" long centered on the water closet.
Where wall space does not permit a 36" grab bar due to a recessed fixture adjacent to the water closet.
Findings - Compliant grab bars Not Provided
I.1. The centerline of the water closet fixture shall be centered 17" to 18" from the side wall or partition. In Ambulatory compartments, the center of the water closet shall be located 17" to 19" from the side wall. CBC 1115B.4.1 Accessible Water Closet / 28 CFR Part 36 App "A" 4.16 Water Closets / 2010 ADA Standards for Accessible Design 604.2
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 76 of 92231
J.1. Install water closet with a seat height of 17" - 19" above finish floor. The height of accessible water closet shall be a minimum of 17" and a maximum of 19" measured to the top of a maximum 2" high toilet seat. Exception: A 3" toilet seat shall be permitted only in alterations where the existing fixture is less than 15" high. CBC 1115B.4.1.4 Accessible Water Closet. / 28 CFR Part 36 App "A" Water Closets / L.1. Provide knee clearance at lavatory. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-603 / 28 CFR Part 36 App "A" 4.19 / 2010 ADAS 603 ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 77 of 92232
L.1.
Findings - Curtain blocking knee clearance
N.1. Install sink controls that do not require tight grasping, pinching or twisting. Control shall be operable with one hand and shall not require tight grasping, pinching or twisting. The force to activate controls shall be no greater than 5lbs force. Lever-operated, push-type, and electronically controlled mechanisms are example of expectable designs.
If self-closing valves are used the faucet shall remain open for at least 10 seconds. CBC 1115B.4.3 Accessible lavatories / 28 CFR Part 36 App. "A" 4.19 Lavatories & Mirrors/ Findings - Twist type
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 78 of 92233
O.1. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition. . CBC 11B-606 / 28 CFR Part 36 App "A" 4.19 Lavatories and Mirrors P.1. Provide insulated wrapping around pipes under sink. Hot water and drainpipes accessible under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. CBC 1115B.4.3.4 Accessible Lavatories / 28 CFR Part 36 App "A" 4.24.6 Exposed Pipes and Surfaces Findings - Exposed pipes
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 79 of 92234
Q.1. 11B-603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches maximum above the finish floor or ground. CBC11B-603.3 / 28 CFR Pt36 App A 4.19.6 / 2010 ADA Standards for Accessible Design 6.3.3 Findings - 53" / Greater than 40" to reflective surface.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 80 of 92235
R.1. Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor. CBC 11B-603.5. / 28 CFR Part 36 App "A" 4.16.6 Dispensers Findings - (42" Soap Dispenser) ( 63" for Towel Dispenser) (60" Seat Covers) ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 81 of 92236
S.1. 11B-604.7 Dispensers. Toilet paper dispensers shall comply with 11B-309.4 (Operation) and shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be below the grab bar, 19 inches minimum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. / 28 CFR Part 36 App. "A" 4.16.6 Dispensers
T.1. 11B-604.8.3 Coat Hooks and Shelves. Coat hooks shall be located within one of the reach ranges specified in 11B-308 (Reach Ranges). Shelves shall be located 40 inches minimum and 48 inches maximum above the finish floor..2010 ADAS 604.3
Findings - 67" to top of hook
U.1.
Estimated Cost: $15,000
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 82 of 92237
15(B) . Men's Restroom
See Women's Restroom for codes and requirements. Violation only depicted in this section.
No accessible compartment provided in this restroom. This entire restroom needs to be redesigned to meet current accessibility requirements.
C N/C Yes No I N/I A/R N/A A
A.2. Required clearance at water closet shall be provided. • B.2. Stall door handles •
C.2.
Toilet stall doors shall be at least 32" wide on end doors or 34" on side doors to stalls.
•
D.2. Grab Bars shall be provided. •
E.2. Water closet seat cover shall be 17"-19" above finish floor. • F.2.
Faucet controls shall be operable with one hand without grasping, pinching or twisting with 5lbs max force to activate.
•
G.2. Exposed pipes under sinks shall be sufficiently insulated against contact. • H.2.
Accessible urinals shall be min 14" and max 17" from rear wall and 17" max from finish floor to rim.
•
I.2. The lever on the urinal shall be 44" max above finish floor. • J.2. Mirror shall be 40" max above finish floor if provided. • K.2.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
L.2. Coat Hooks shall be 48" maximum to the top of the hook. • M.2.
Shelves shall be mounted 40" minimum to 48" maximum per the ADA 603.4 / The CBC states 44" shelf provided in a medicine cabinet if provided. •
N.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 83 of 92238
Comments:
A.2. 11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 11B-604.3.
Findings - No accessible compartment provided.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 84 of 92239
E.2.
Existing toilets in restroom are 15-1/2" AFF. Accessible toilets shall meet this code.
F.2.
Twist type - Lever type or automatic required
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 85 of 92240
G.2.
Exposed Pipes
H.2. Prove accessible urinal. Urinals shall be floor mounted, stall type or wall hung. Where one or more wall-hung urinals are provided, at least one with an elongated rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided. CBC 11B-605.2 / 28 CFR Part 36 App "A" 4.18 Urinals / 2010 ADAS 605.2 Findings - 19" to top of rim.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 86 of 92241
I.2. 11B-605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 11B- 309 (Operable Parts) except that the flush control shall be mounted at a maximum height of 44 inches above the finish floor.
Findings - 48" AFF
J.2. Findings - 45" / Greater than 40" to reflective surface above finish floor.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 87 of 92242
K.2.
(61" for Towel Dispenser) Provide at least one at 40" max to top of operable part.
L.2. Provide at least (1) hook and shelf at 48" max AFF ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 88 of 92243
M.2.
Provide a shelf at 48" max AFF
N.2.
Estimated Cost: $15,000 Redesign and construction
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 89 of 92244
16. Stage Areas
C N/C Yes No I N/I A/R N/A A
A. Stage areas shall be accessible. •
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. CBC 11B-206.2.4 Spaces and Elements Spaces and Elements. At least one accessible route shall connect accessible building or facility with all accessible spaces and elements within a building or facility which are otherwise connected by a circulation path unless exempted by 206.2.3 Exemption.... / 2010 ADAS 206.2.4 / 28CFR Pt 36 App A
4.3.2 (2)
11B-206.7 Platform Lifts. Platform lifts shall comply with 11B-410 (Platform Lifts). Platform lifts shall be permitted as a component of an accessible route in new construction in accordance with 11B- 206.7. Platform lifts shall be permitted as a component of an accessible route in an existing building or facility. 11B-206.7.1 Performance Areas and Speakers’ Platforms. Platform lifts shall be permitted to provide accessible routes to performance areas and speakers’ platforms.
Findings - No access to stage
Recommendation: Provide a lift or a ramp to the stage platform.
B.
Estimated Cost: $4000 for a ramp / $7000 for a lift.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 90 of 92245
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 91 of 92246
Evaluation Statement
This ADA Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at Clark Building - 861 Valley Dr., Hermosa Beach, CA 90254. This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply.
ADA Inspection Plus, LLC
Clark Building - 861 Valley Dr. Page 92 of 92247
Appendix B – ADA Evaluation Reports
A.3 Valley Park Building (ADA Plus LLC)
248
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
Valley Park Building - 2521 Valley Dr.
Hermosa Beach CA 90254
Inspection Date: 4/8/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
249
Date: 4/8/2015 Report ID: H.B.003
Property:
Valley Park Building - 2521
Valley Dr.
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
This report is for construction-related accessibility standards only as required by CASp requirements.
Construction related non-compliance elements in this report shall be considered to fall under "readily achievable barrier removal" unless otherwise noted in the comments for any item in this report. If construction of an item was completed after applicable codes and regulation went into affect, the items are considered to be non-conforming construction practices and shall be modified to meet the current standards.
It is highly recommended to secure a qualified contractor and or architect for all modifications performed for accessibility compliance. It is the responsibility of the owner and contractor to adhere to all requirements set forth in State and Local jurisdictions including permits if required. "Certified Access Specialist" or "CASp" means any person who has been certified pursuant to Section 4459.5 of the CA Government Code.
Technically Infeasible. With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member that is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces, or features that are in full and strict compliance with the minimum requirements.
The following requirements must be met for this CASp Evaluation Report to be recognized in California Litigation for a "Qualified Defendant" as defined in SB1608 and SB1186
(A) An identification and description of the inspected structures and areas of the site. (B) A statement that, in the opinion of the CASp, the inspected structures and areas of the site need correction to meet constructionrelated accessibility standards. This statement shall clearly indicate whether the determination of the CASp includes an assessment of readily achievable barrier removal.
(C) An identification and description of the structures or areas of the site that need correction and the correction needed. (D) A schedule of completion for each of the corrections within a reasonable time frame. (b) For purposes of this section, in determining whether the site meets applicable construction-related accessibility standards when there is a conflict or difference between a state and federal provision, standard, or regulation, the state provision, standard, or regulation shall apply unless the federal provision, standard, or regulation is more protective of accessibility rights. (c) Every CASp who conducts an inspection of a place of public accommodation shall, upon completing the inspection of the site, provide the building owner or tenant who requested the inspection with the following notice, which the State Architect shall make available as a form on the State Architect’s Internet Web site:
NOTICE TO PRIVATE PROPERTY OWNER/TENANT:
YOU ARE ADVISED TO KEEP IN YOUR RECORDS ANY WRITTEN INSPECTION REPORT AND ANY OTHER
DOCUMENTATION CONCERNING YOUR PROPERTY SITE THAT IS GIVEN TO YOU BY A CERTIFIED ACCESS SPECIALIST.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 2 of 26250
IF YOU BECOME A DEFENDANT IN A LAWSUIT THAT INCLUDES A CLAIM CONCERNING A SITE INSPECTED BY A
CERTIFIED ACCESS SPECIALIST, YOU MAY BE ENTITLED TO A COURT STAY (AN ORDER TEMPORARILY STOPPING ANY LAWSUIT) OF THE CLAIM AND AN EARLY EVALUATION CONFERENCE.
IN ORDER TO REQUEST THE STAY AND EARLY EVALUATION CONFERENCE, YOU WILL NEED TO VERIFY THAT A CERTIFIED ACCESS SPECIALIST HAS INSPECTED THE SITE THAT IS THE SUBJECT OF THE CLAIM. YOU WILL ALSO BE
REQUIRED TO PROVIDE THE COURT AND THE PLAINTIFF WITH THE COPY OF A WRITTEN INSPECTION REPORT BY THE CERTIFIED ACCESS SPECIALIST, AS SET FORTH IN CIVIL CODE SECTION 55.54. THE APPLICATION FORM AND
INFORMATION ON HOW TO REQUEST A STAY AND EARLY EVALUATION CONFERENCE MAY BE OBTAINED AT www.courts.ca.gov/selfhelp-start.htm.
YOU ARE ENTITLED TO REQUEST, FROM A CERTIFIED ACCESS SPECIALIST WHO HAS CONDUCTED AN INSPECTION
OF YOUR PROPERTY, A WRITTEN INSPECTION REPORT AND OTHER DOCUMENTATION AS SET FORTH IN CIVIL CODE SECTION 55.53. YOU ARE ALSO ENTITLED TO REQUEST THE ISSUANCE OF A DISABILITY ACCESS INSPECTION CERTIFICATE, WHICH YOU MAY POST ON YOUR PROPERTY.
“Meets applicable standards” means the site was inspected by a CASp and determined to meet all applicable construction-related accessibility standards pursuant to paragraph (1) of subdivision (a) of Section 55.53. A site that is “CASp inspected” on or before the effective date of the amendments made to this section by Senate Bill 1186 of the 2011–12 Regular Session of the Legislature means that the site “meets applicable standards.”
“Inspected by a CASp” means the site was inspected by a CASp and is pending a determination by the CASp that the site meets applicable construction-related accessibility standards pursuant to paragraph (2) of subdivision (a) of Section 55.53. A site that is “CASp determination pending” on or before the effective date of the amendments made to this section by Senate Bill 1186 of the 2011–12 Regular Session of the Legislature means that the site was “inspected by a CASp.” The Americans with Disabilities Act is a civil rights law that was enacted in 1990 to provide persons with disabilities with accommodations and access equal to, or similar to, that available to the general public. Title III of the ADA requires that owners of buildings that are considered to be places of public accommodations remove those architectural barriers and communications barriers that are considered readily achievable in accordance with the resources available to building ownership to allow use of the facility by the disabled. The obligation to remove barriers where readily achievable is an ongoing one. The determination as to whether removal of a barrier or an implementation of a component or system is readily achievable is often a business decision, which is based on the resources available to the owner or tenants, and contingent upon the timing of implementation as well. Determination of whether barrier removal is readily achievable is on a case-by-case basis; the United States Department of Justice did not provide numerical formulas or thresholds of any kind to determine whether an action is readily achievable.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title III (Public Accommodation and Commercial Facilities) Compliance dates for the 2010 Standards for new construction and alterations is determined by: the date the last application for a building permit or permit extension is certified to be complete by a State, county, or local government; the date the last application for a building permit or permit extension is received by a State, county, or local government, where the government does not certify the completion application; or, the state of physical construction or alteration, if no permit is required. If that date is on or after March 15, 2012, then new construction and alterations must comply with the 2010 Standards. If that date is on or after September 15, 2010 and before March 15, 2012, then new construction and alterations must comply with either the 1991 Standards or the 2010 Standards. / Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 3 of 26251
Senate Bill No. 1608 & Senate Bill no. 1186 provides relief for qualified defendants. Consult with an attorney with knowledge in accessibility requirements and the ADA.
Building Use:
Restrooms, Storage and Snack Bar
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 4 of 26252
Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Inspection Scope .....................................................6 2 Miscellaneous Doors................................................7 3(A) Men's Restroom Door .........................................9 3(B) Women's Restroom Doors ................................12 4(A) Men's Restroom ................................................15 4(B) Women's Restroom...........................................19 5 Drinking Fountains.................................................23 Agreement ................................................................26 ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 5 of 26253
1. Inspection Scope
C N/C Yes No I N/I A/R N/A A
A. Inspection Scope and Areas. •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
Valley Park Building and concrete around the building.
Note: Park Parking & Accessible Routes to and from. Through the park not inspected.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 6 of 26254
2. Miscellaneous Doors
C N/C Yes No I N/I A/R N/A A
A. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • B.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 7 of 26255
Comments:
A. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - 31-3/4" clear wide
B. Adjust or provide door closure so that from an opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door. CBC 11B-404.2.8.1 / 28 CFR Part 36 App. A - 4.13.10 / 2010 ADAS-404.2.8.1 / Spring hinges are 70deg to closed position in 1.5 seconds minimum)
Findings - 3 Seconds 90-12
C.
Estimated Cost: $2500.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 8 of 26256
3(A) . Men's Restroom Door
C N/C Yes No I N/I A/R N/A A
A.1.
Men's sanitary facility - proper signs (1/4" thick, 12" equilateral triangle / light on dark or dark on light) Permanent Room Identification Sign (Braille) •
B.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 9 of 26257
Comments:
A.1. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 10 of 26258 A.1.
Tactile Sign Not Provided
B.1.
Estimated Cost: $50
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 11 of 26259 3(B) . Women's Restroom Doors
C N/C Yes No I N/I A/R N/A A
A.2.
Women's sanitary facility - proper signs (1/4" thick, 12" circle / light on dark or dark on light)
•
B.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 12 of 26260 Comments:
A.2. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 13 of 26261 A.2.
Tactile Sign Not Provided
B.2.
Estimated Cost: $50
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 14 of 26262 4(A) . Men's Restroom
C N/C Yes No I N/I A/R N/A A
A.1.
Compartment door handles shall be U-shaped or lever type mounted below compliant latch and on both sides of the door.
•
B.1. Water closet shall be centered 17" to 18" center from side wall. • C.1. Exposed pipes under sinks shall be sufficiently insulated against contact. • D.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 15 of 26263 Comments:
A.1. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Missing on exterior of door.
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 16 of 26264 B.1. The centerline of the water closet fixture shall be centered 17" to 18" from the side wall or partition. In Ambulatory compartments, the center of the water closet shall be located 17" to 19" from the side wall. CBC 1115B.4.1 Accessible Water Closet / 28 CFR Part 36 App "A" 4.16 Water Closets / 2010 ADA Standards for Accessible Design 604.2
Findings - 19-1/2" from side wall
C.1. Provide insulated wrapping around pipes under sink. Hot water and drainpipes accessible under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. CBC 1115B.4.3.4 Accessible Lavatories / 28 CFR Part 36 App "A" 4.24.6 Exposed Pipes and Surfaces Findings - Exposed Pipe and hot water line
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 17 of 26265 D.1.
Estimated Cost: $2500
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 18 of 26266 4(B) . Women's Restroom
C N/C Yes No I N/I A/R N/A A
A.2.
Compartment door shall have be self-closing with 1.5 second minimum closure time from 70deg to 3" (CBC) and 5 seconds from 90deg to 12 deg (ADA)
•
B.2. Water closet shall be centered 17" to 18" center from side wall. • C.2.
Toilet tissue dispenser shall be within 7" minimum to 9" to the center of dispenser maximum from the front of water closet 19" minimum from the floor to the outlet of the dispenser and mounted below the grab bar. •
D.2. Exposed pipes under sinks shall be sufficiently insulated against contact. • E.2.
Mirror shall be 40" max to reflective surface and 74" minimum to the top of the reflective surface above finish floor if provided.
•
F.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.2. The door shall be self-closing. A door pull complying with 11B-404.2.7 (Door and Gate Hardware) shall be placed on both sides of the door near the latch with a 1.5 second minimum closing time from 70 deg (2010 ADA 404.2.8.2 Spring Hinges)
Findings - Partition door does not close automatically
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 19 of 26267 B.2. The centerline of the water closet fixture shall be centered 17" to 18" from the side wall or partition. In Ambulatory compartments, the center of the water closet shall be located 17" to 19" from the side wall. CBC 1115B.4.1 Accessible Water Closet / 28 CFR Part 36 App "A" 4.16 Water Closets / 2010 ADA Standards for Accessible Design 604.2
Findings - 19" from side wall
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 20 of 26268 C.2. 11B-604.7 Dispensers. Toilet paper dispensers shall comply with 11B-309.4 (Operation) and shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be below the grab bar, 19 inches minimum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. / 28 CFR Part 36 App. "A" 4.16.6 Dispensers
Findings - Incorrect mounting location
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 21 of 26269 D.2. Provide insulated wrapping around pipes under sink. Hot water and drainpipes accessible under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. CBC 1115B.4.3.4 Accessible Lavatories / 28 CFR Part 36 App "A" 4.24.6 Exposed Pipes and Surfaces Findings - Partially Exposed
E.2. 11B-603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches maximum above the finish floor or ground. CBC11B-603.3 / 28 CFR Pt36 App A 4.19.6 / 2010 ADA Standards for Accessible Design 6.3.3 Findings -Greater than 40" to reflective surface.
F.2.
Estimated Cost: $2500
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 22 of 26270
5. Drinking Fountains
C N/C Yes No I N/I A/R N/A A
A.
Fountain shall be located in an alcove. Not less than 32" between wing walls and 18" minimum in depth. If a High/Low fountain is provided, Width will vary however and clear floor space shall be provided at the low fountain. If the wing wall is greater than 24" in depth, add 6" to the width of the clear floor space. •
B. The flow of water shall be at least 4" high. •
C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 23 of 26271 Comments:
A. Drinking fountains shall be located in an alcove, between wing walls, or positioned not to project into the accessible route more than 4". Alcoves may be railing protection but may not be greater than 6: above finish floor.
CBC 11B-602
Findings - Wing walls or protection railing not provided ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 24 of 26272 B. The water flow shall be 4" minimum high and shall be 5" maximum from the front of the fountain including bumpers. The angle of the water flow stream shall be measured horizontally relative to the front of the unit. Where the water stream is located 3" to 5" the angle shall be 15 degrees maximum. When the water stream is up to 3" the water stream shall be 30 degrees maximum from the face of the unit. CBC 11B-602.6 / ADA 602.6 Water Flow Findings - Trickles out of spout for low. Approx. 2" for higher fountain C.
Estimated Cost: $1000
ADA Inspection Plus, LLC
Valley Park Building - 2521 Valley Dr. Page 25 of 26273 ADA Inspection Plus, LLC
CASp Evaluation Statement
This CASp Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at Valley Park Building - 2521 Valley Dr., Hermosa Beach, CA 90254. This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply. The areas of the property, dictated by City of Hermosa Beach , and only those areas dictated by City of Hermosa Beach , were inspected for code requirements and addressed in this report under the terms of a CASp Evaluation Agreement. The agreement was signed and agreed upon before the preparation of this report.
Valley Park Building - 2521 Valley Dr. Page 26 of 26274 Appendix B – ADA Evaluation Reports
A.4 Kiwanis Shared Building Exterior Access & Parking (ADA Plus LLC) 275
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
Kiwani's Buildings Shared Exterior & Parking
Hermosa Beach CA 90254
Inspection Date: 4/8/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
276
Date: 4/8/2015 Report ID: H.B.004
Property:
Kiwani's Buildings Shared
Exterior & Parking
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
This report is for construction-related accessibility standards only as required by CASp requirements.
Construction related non-compliance elements in this report shall be considered to fall under "readily achievable barrier removal" unless otherwise noted in the comments for any item in this report. If construction of an item was completed after applicable codes and regulation went into affect, the items are considered to be non-conforming construction practices and shall be modified to meet the current standards.
It is highly recommended to secure a qualified contractor and or architect for all modifications performed for accessibility compliance. It is the responsibility of the owner and contractor to adhere to all requirements set forth in State and Local jurisdictions including permits if required. "Certified Access Specialist" or "CASp" means any person who has been certified pursuant to Section 4459.5 of the CA Government Code.
Technically Infeasible. With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member that is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces, or features that are in full and strict compliance with the minimum requirements.
The following requirements must be met for this CASp Evaluation Report to be recognized in California Litigation for a "Qualified Defendant" as defined in SB1608 and SB1186
(A) An identification and description of the inspected structures and areas of the site. (B) A statement that, in the opinion of the CASp, the inspected structures and areas of the site need correction to meet constructionrelated accessibility standards. This statement shall clearly indicate whether the determination of the CASp includes an assessment of readily achievable barrier removal.
(C) An identification and description of the structures or areas of the site that need correction and the correction needed. (D) A schedule of completion for each of the corrections within a reasonable time frame. (b) For purposes of this section, in determining whether the site meets applicable construction-related accessibility standards when there is a conflict or difference between a state and federal provision, standard, or regulation, the state provision, standard, or regulation shall apply unless the federal provision, standard, or regulation is more protective of accessibility rights. (c) Every CASp who conducts an inspection of a place of public accommodation shall, upon completing the inspection of the site, provide the building owner or tenant who requested the inspection with the following notice, which the State Architect shall make available as a form on the State Architect’s Internet Web site:
NOTICE TO PRIVATE PROPERTY OWNER/TENANT:
YOU ARE ADVISED TO KEEP IN YOUR RECORDS ANY WRITTEN INSPECTION REPORT AND ANY OTHER
DOCUMENTATION CONCERNING YOUR PROPERTY SITE THAT IS GIVEN TO YOU BY A CERTIFIED ACCESS SPECIALIST.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 2 of 33277
IF YOU BECOME A DEFENDANT IN A LAWSUIT THAT INCLUDES A CLAIM CONCERNING A SITE INSPECTED BY A
CERTIFIED ACCESS SPECIALIST, YOU MAY BE ENTITLED TO A COURT STAY (AN ORDER TEMPORARILY STOPPING ANY LAWSUIT) OF THE CLAIM AND AN EARLY EVALUATION CONFERENCE.
IN ORDER TO REQUEST THE STAY AND EARLY EVALUATION CONFERENCE, YOU WILL NEED TO VERIFY THAT A CERTIFIED ACCESS SPECIALIST HAS INSPECTED THE SITE THAT IS THE SUBJECT OF THE CLAIM. YOU WILL ALSO BE
REQUIRED TO PROVIDE THE COURT AND THE PLAINTIFF WITH THE COPY OF A WRITTEN INSPECTION REPORT BY THE CERTIFIED ACCESS SPECIALIST, AS SET FORTH IN CIVIL CODE SECTION 55.54. THE APPLICATION FORM AND
INFORMATION ON HOW TO REQUEST A STAY AND EARLY EVALUATION CONFERENCE MAY BE OBTAINED AT www.courts.ca.gov/selfhelp-start.htm.
YOU ARE ENTITLED TO REQUEST, FROM A CERTIFIED ACCESS SPECIALIST WHO HAS CONDUCTED AN INSPECTION
OF YOUR PROPERTY, A WRITTEN INSPECTION REPORT AND OTHER DOCUMENTATION AS SET FORTH IN CIVIL CODE SECTION 55.53. YOU ARE ALSO ENTITLED TO REQUEST THE ISSUANCE OF A DISABILITY ACCESS INSPECTION CERTIFICATE, WHICH YOU MAY POST ON YOUR PROPERTY.
“Meets applicable standards” means the site was inspected by a CASp and determined to meet all applicable construction-related accessibility standards pursuant to paragraph (1) of subdivision (a) of Section 55.53. A site that is “CASp inspected” on or before the effective date of the amendments made to this section by Senate Bill 1186 of the 2011–12 Regular Session of the Legislature means that the site “meets applicable standards.”
“Inspected by a CASp” means the site was inspected by a CASp and is pending a determination by the CASp that the site meets applicable construction-related accessibility standards pursuant to paragraph (2) of subdivision (a) of Section 55.53. A site that is “CASp determination pending” on or before the effective date of the amendments made to this section by Senate Bill 1186 of the 2011–12 Regular Session of the Legislature means that the site was “inspected by a CASp.” The Americans with Disabilities Act is a civil rights law that was enacted in 1990 to provide persons with disabilities with accommodations and access equal to, or similar to, that available to the general public. Title III of the ADA requires that owners of buildings that are considered to be places of public accommodations remove those architectural barriers and communications barriers that are considered readily achievable in accordance with the resources available to building ownership to allow use of the facility by the disabled. The obligation to remove barriers where readily achievable is an ongoing one. The determination as to whether removal of a barrier or an implementation of a component or system is readily achievable is often a business decision, which is based on the resources available to the owner or tenants, and contingent upon the timing of implementation as well. Determination of whether barrier removal is readily achievable is on a case-by-case basis; the United States Department of Justice did not provide numerical formulas or thresholds of any kind to determine whether an action is readily achievable.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title III (Public Accommodation and Commercial Facilities) Compliance dates for the 2010 Standards for new construction and alterations is determined by: the date the last application for a building permit or permit extension is certified to be complete by a State, county, or local government; the date the last application for a building permit or permit extension is received by a State, county, or local government, where the government does not certify the completion application; or, the state of physical construction or alteration, if no permit is required. If that date is on or after March 15, 2012, then new construction and alterations must comply with the 2010 Standards. If that date is on or after September 15, 2010 and before March 15, 2012, then new construction and alterations must comply with either the 1991 Standards or the 2010 Standards. / Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 3 of 33278 Senate Bill No. 1608 & Senate Bill no. 1186 provides relief for qualified defendants. Consult with an attorney with knowledge in accessibility requirements and the ADA.
Building Use:
Public Use Buildings
Age Of building:
Pre ADA Regulations
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 4 of 33279 Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Inspection Scope .....................................................6 2 Site Arrival Points.....................................................7 3 Overall Parking ........................................................9 4(A) Parking Space 1................................................13 4(B) Parking Space 2................................................21 5 Accessible Routes Exterior....................................25 6 Stairways ...............................................................28 Agreement ................................................................33 ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 5 of 33280
1. Inspection Scope
C N/C Yes No I N/I A/R N/A A
A. Inspection Scope and Areas. •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
Exterior Only; Site Access, Parking, Accessible Routes, Signage, Common Areas.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 6 of 33281
2. Site Arrival Points
C N/C Yes No I N/I A/R N/A A
A.
At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking spaces, passenger loading zones, if provided, and public streets and sidewalks.
•
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 7 of 33282 Comments:
A. At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking, and accessible passenger loading zones, and public streets or sidewalks. Provide accessible route of travel to and from all accessible buildings and accessible facilities. CBC 11B-206 / 28 CFR Part 36 App. A -
4.3 / ADA 2010 Standards: 206 Accessible Route.
Findings - No accessible route provided from the city right-of-way.
Provide new ramp.
B.
Estimated Cost: $10,000
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 8 of 33283
3. Overall Parking
C N/C Yes No I N/I A/R N/A A
A.
Sufficient accessible parking spaces with respect to the total number of reported spaces.
•
B. Sufficient number of van-accessible parking spaces. • C. "Unauthorized Vehicle Tow Away" Sign •
D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 9 of 33284 Comments:
A. 11B-208.1 General. Where parking spaces are provided, parking spaces shall be provided in accordance with 11B-208.
11B-208.2 Minimum Number. Parking spaces complying with 11B-502 (Parking Spaces) shall be provided in accordance with Table 11B-208.2 except as required by 11B-208.2.1 (Hospital Outpatient Facilities) 11B-208.2.2 (Rehabilitation Facilities and Outpatient Physical Therapy Facilities )and 11B-208.2.3 (Rehabilitation Facilities and Outpatient Physical Therapy Facilities) Where more than one parking facility is provided on a site, the number of accessible spaces provided on the site shall be calculated according to the number of spaces required for each parking facility.
TOTAL OVERALL PARKING SPACES PROVIDED = 36 Overall
TOTAL ACCESSIBLE PARKING SPACES PROVIDED = 2 (one for park and one for buildings.) TOTAL REQUIRED ACCESSIBLE PARKING SPACES = 2
B. Six or a fraction of six parking spaces shall be VAN ACCESSIBLE. ADA 2010 Standards: 208.2.4 Van Parking Spaces / One in every eight accessible spaces (for Safe Harbor), but not less than one, shall be van accessible with the access isle on the passenger side of the parking space. CBC 11B-208.2.4 Van Spaces.
Findings - Parking between buildings shall be Van accessible.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 10 of 33285 C. Provide a new "Unauthorized Vehicle Tow Away" (R100B) sign with the proper information with a minimum 17"x22" with 1" lettering at each site entrance or in view of each accessible space. Sign shall read" UNAUTHORIZED
VEHICLES PARKED IN DESIGNATED ACCESSIBLE SPACES NOT DISPLAYING DISTINGUISHING PLACARDS
OR SPECIAL LICENSE PLATES ISSUED FOR PERSONS WITH DISABILITIES WILL BE TOWED AWAY AT THE OWNER'S EXPENSE...TOWED VEHICLES MAY BE CLAIMED AT....OR BY TELEPHONING... CBC 11B-502.8 ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 11 of 33286 C.
Findings - Outdated wording and missing required information.
D. See Parking Spaces Section for cost estimates.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 12 of 33287 4(A) . Parking Space 1
C N/C Yes No I N/I A/R N/A A
A.1.
An accessible route must be provided from accessible parking to an accessible entrance.
•
B.1.
Wheel Stop or curb to prevent vehicles from walking surface. Shortest possible route. Not forced to walk behind spaces other than the persons own space.
•
C.1.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
D.1.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
E.1. Accessible stall striping. •
F.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.1. Parking shall connect to the shortest possible accessible route to the accessible entrance/s. CBC 11B-502.7 / 28 CFR Part 36 App A - 4.6.2 Location. / ADA 2010 Standards: 208.3 Location Findings - See "Accessible Routes Exterior" Section
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 13 of 33288 C.1. Signs shall be provided at spaces for each parking stall space for persons with disabilities. Signs shall be identified by a reflective sign no less than 70 square inches with a white ISA on blue background and additional language below the symbol of accessibility stating "Minimum Fine $250". Van spaces must have a sign reading "Van Accessible" Bottom of sign must be mounted Minimum 80" above finish elevation in areas of pedestrian access. 60" Min. above finish elevation if centered on a wall. 2013 CBC 11B-502.6. / 28 CFR Part 36 App A: 4.6.4 / ADA 2010 Standards: 502.6 Identification.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 14 of 33289 C.1. Missing "Minimum FINE $250" sign
Missing VAN ACCESSIBLE sign
Incorrect Sign
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 15 of 33290 D.1. Surfaces shall not exceed 1:48 (2%) max slope in any direction at accessible parking spaces and access aisle.
CBC 11B-502.4 / 28 CFR Part 36 App. A - 4.6 / ADA 2010 Standards: 502.4 Floor and Ground Surfaces. Changes in level are not permitted.
Findings - 3.0% / 3.3% / 3.9%
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 16 of 33291 ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 17 of 33292 E.1. Stripe accessible parking space with 36"x36" ISA (White on Blue), 216" (18') long 108" (9') wide with blue boarder measured centerline to centerline. White 12" "NO PARKING" in access aisle. Diagonal lines in access aisle ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 18 of 33293 at 36" O.C. Access aisle shall be 60" (5') wide for standard accessible stall. A van space width shall be 144" with a 60" wide access aisle. Exception: permitted to be 108" min wide when the access aisle is 96" (8') wide min. Van access aisle shall be on the passenger side of vehicle. CBC 11B.502 Parking Spaces. / 28 CFR Part 36 App A: 4.6.3 Parking Spaces (Modified Layout) / ADA 2010 Standards: 502 Parking Spaces.(Modified Layout) E.1. Missing NO PARKING Stencil
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 19 of 33294 E.1.
Findings - 80" / Van Access Aisle less than 96" Minimum (8') measured centerline to centerline. (Minor Violation)
E.1.
Findings - 192" / Space and/or accessible parking less than 216" (18') in length.
F.1.
Estimated Cost: $5000
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 20 of 33295 4(B) . Parking Space 2
C N/C Yes No I N/I A/R N/A A
A.2.
Accessible spaces marked with the International Symbol of Accessibility, reflectorized, 70 square in. min. or a "Minimum Fine $250" "Van Accessible" / Bottom of sign must have a clearance of 80" to walking surface. •
B.2.
Accessible parking spaces and adjacent aisle shall not exceed 1:48 (2%) in any direction.
•
C.2. Accessible stall striping. •
D.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 21 of 33296 Comments:
A.2. Missing "Minimum FINE $250" sign
Missing VAN ACCESSIBLE sign
Incorrect Sign
B.2. Surfaces shall not exceed 1:48 (2%) max slope in any direction at accessible parking spaces and access aisle.
CBC 11B-502.4 / 28 CFR Part 36 App. A - 4.6 / ADA 2010 Standards: 502.4 Floor and Ground Surfaces. Changes in level are not permitted.
Findings -
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 22 of 33297 B.2.
Violations Found: Exceeds 1:48 (2%) in parking and/or access aisles (Findings - 3.3% slope in access aisle at accessible route join.)
C.2. Missing NO PARKING Stencil
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 23 of 33298 C.2.
Findings - 187" / Space and/or accessible parking less than 216" (18') in length. (Minor Violation) D.2.
Estimated Cost: $2500
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 24 of 33299
5. Accessible Routes Exterior
C N/C Yes No I N/I A/R N/A A
A. Walks (48" wide minimum and 2% max cross slope) ( 5% max running slope) • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide compliant walks for accessible routes with 48" minimum width, 1:48 (2%) or less cross slopes & 1:20 (5%) or less running slopes. 11B-403 Walking Surfaces / 28 CFR Part 36 App. A - 4.3 / ADA 2010 Standards: 403 Walking Surfaces (Less Restrictive)
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 25 of 33300 A.
Access from accessible parking to south building.
Cross Slopes exceed 1:48 (2%) 48" minimum wide clear. (Findings- 2.8% / 4.2%) Slopes exceed 1:20 (5%) and shall be considered a "RAMP" (Landings and Handrailing Required) ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 26 of 33301 A. 11B-405.8 Handrails. Ramp runs shall have handrails complying with 11B-505 (Handrails).
EXCEPTION: 4. At door landings, handrails are not required on ramp runs less than 6 inches in rise or 72 inches in length.
Findings - 12.2% slope in the direction of travel. / The slopes at the door landing was found to have extreme slopes in the direction of travel. A complete design for the entry door for the south building will need design to determine the most cost effective remediation.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 27 of 33302
6. Stairways
C N/C Yes No I N/I A/R N/A A
A. Treads and riser shall be uniform in size. •
B.
The railings shall extend 12" horizontal past the top and bottom stair as required.
•
C. Stairs have a stripe on the treads (1" from nose, 2"-4" stripe the width of tread) • D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-504.2 Treads and Risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches high minimum and 7 inches high maximum. Treads shall be 11 inches deep minimum. 11B-504.3 Open Risers. Open risers are not permitted.. 2010 ADA Standards - 504.2 Treads and Risers Findings - Risers not equal heights
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 28 of 33303 B. Modify handrail to extend a minimum of 12" beyond the top nosing and 12" plus tread width, beyond the bottom nosing. At the top, the extension shall be parallel with the floor or ground surface. at the bottom, the handrail shall ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 29 of 33304 continue to slope for a distance of the width of one tread from the bottom riser, the remainder ot the extension shall be horizontal. CBC 11B-505.10.3 / 2010 ADA Standards 505.10.2 Top Extension, 505.10.3 Bottom Extension.
Findings - Level extension not provided at several location on the railing for the three sets of stairs.
ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 30 of 33305 ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 31 of 33306 C. 11B-504.4.1 Contrasting Stripe. Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast. Exterior stairs shall have the upper approach and all treads marked by a stripe providing clear visual contrast. The stripe shall be a minimum of 2 inches wide to a maximum of 4 inches wide placed parallel to, and not more than 1 inch from, the nose of the step or upper approach. The stripe shall extend the full width of the step or upper approach and shall be of material that is at least as slip resistant as the other treads of the stair. A painted stripe shall be acceptable. Grooves shall not be used to satisfy this requirement.
Findings - Contrasting stripe not provided. Typical all 3 sets of exterior stairs.
D.
Estimated Cost: $6000 - Railing and some removal and replacement ADA Inspection Plus, LLC
Kiwani's Buildings Shared Exterior & Parking Page 32 of 33307 ADA Inspection Plus, LLC
CASp Evaluation Statement
This CASp Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at Kiwani's Buildings Shared Exterior & Parking, Hermosa Beach, CA 90254.
This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply. The areas of the property, dictated by City of Hermosa Beach , and only those areas dictated by City of Hermosa Beach , were inspected for code requirements and addressed in this report under the terms of a CASp Evaluation Agreement. The agreement was signed and agreed upon before the preparation of this report.
Kiwani's Buildings Shared Exterior & Parking Page 33 of 33308 Appendix B – ADA Evaluation Reports
A.5 Hermosa Beach Kiwanis Club (ADA Plus LLC)
309
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
HB.005 Kiwani's Building South - 2515 Valley Dr.
Hermosa Beach CA 90254
Inspection Date: 4/8/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
310
Date: 4/8/2015 Report ID: H.B.005
Property:
HB.005 Kiwani's Building South -
2515 Valley Dr.
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 2 of 70311 IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
PROGRAM ACCESSIBILITY for Title II Facilities.
General. A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
ADA.gov - Public entity. A public entity covered by title II is defined as -- 1) Any State or local government;
2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include -- 1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees;
3) Whether the entity receives significant assistance from the government by provision of property or equipment; and
4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
Relationship to title III. Public entities are not subject to title III of the ADA, which covers only private entities.
Conversely, private entities are not subject to title II. In many situations, however, public entities have a close relationship to private entities that are covered by title III, with the result that certain activities may be at least indirectly affected by both titles.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 3 of 70312 California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
Building Use:
Public Use Building
Age Of building:
Pre ADA Regulations
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 4 of 70313 Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Inspection Scope .....................................................6 2 Entrance Doors........................................................7 3 Miscellaneous Doors..............................................13 4 Service Counters ...................................................17 5 Accessible Routes Interior .....................................19 6 Reach Ranges for Operable Parts.........................21 7 Kitchens & Kitchenettes.........................................25 8(A) Men's Restroom Door .......................................26 8(B) Women's Restroom Doors ................................34 9(A) Men's Restroom ................................................39 9(B) Women's Restroom...........................................54 10 Group A Occupancies - Assembly Halls,
Auditoriums, Theaters...............................................67 Agreement ................................................................70 ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 5 of 70314
1. Inspection Scope
C N/C Yes No I N/I A/R N/A A
A. Inspection Scope and Areas. •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
Interior Evaluation including doors, restrooms, kitchen, assembly room.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 6 of 70315
2. Entrance Doors
C N/C Yes No I N/I A/R N/A A
A. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • B.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
C.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
D.
Maneuvering space for forward approach shall be 60" measured from the face of the closed door on the pull side. 48" from push side. Slopes shall not exceed 2% for Manual Doors
•
E. Smooth surface 10" at the bottom of door on the push side. • F.
An EXIT sign with Contracted Grade II Braille shall be placed on the strike side of the interior spaces leading to an accessible Exit.
•
G. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 7 of 70316 Comments:
A. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates A. Findings - 27-1/2" wide clear. / Typical findings at entry doors ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 8 of 70317 B.
No Closure Provided
C.
No Closure Provided
D. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 9 of 70318 D.
Findings- 48" / Less than 60" from pull side of door
E. Provide a 10" smooth panel on the push side of door or gate. Cap all voids at top of smooth panel if void is present. CBC 11B-404.2.10 / ADA 2010 Standards: 404.2.10 Door and Gate Surfaces (Exception 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor shall not be required to provide smooth surfaces complying with 404.2.10 provided that if added kick plates are installed, cavities created by the kick plates are capped.)
Findings - Door hardware within 10" smooth area.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 10 of 70319 F. Provide tactile EXIT sign at exit doors in accordance with CBC 11B-703 Signs / ADA 2010 Standards: 216.4 Means of Egress / No provisions in 28 CFR Pt 36 App A.
Findings - Not provided
F. "EXIT ROUTE" sign required
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 11 of 70320 F. "EXIT" sign required
F. "EXIT STAIRS DOWN" sign required
G.
Estimated Cost: $7000 for new entry doors and exterior landings.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 12 of 70321
3. Miscellaneous Doors
These two exit doors are not currently accessible and not required to be. If alteration are performed, these two doors may be required to meet current code and be accessible for accessible egress.
C N/C Yes No I N/I A/R N/A A
A. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • B.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest. (15lbs for panic hardware release) •
D.
Maneuvering space of 60" measured from the face of the closed door on the pull side. 48" from push side. (44" Exception) - Additional Requirements for Doors & Sliding Doors.
•
E. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 13 of 70322 Comments:
A. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - Existing storage doors have less than 32" min clear widths. These doors required to be accessible if accessed by the public.
B. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 14 of 70323 B.
Several doors within the space have twist type door handles. Replace with level type door handles C. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware which ever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 15 of 70324 C. North Facing egress door / Findings - Extremely difficult to activate panic bar.
D.
Exit doors may be required when alteration are preformed to meet current accessible egress requirements.
Current conditions have stairs down to the ground level E.
Estimated Cost: $10,000 for doors accessed by the public and proposed accessible egress.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 16 of 70325
4. Service Counters
C N/C Yes No I N/I A/R N/A A
A. Counter top shall be 36" minimum width and 28" to 34" high maximum. • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 17 of 70326 Comments:
A. Provide or modify sales or service counter to 28" minimum to 34" maximum height and 36" minimum long. Where counters have cash registers and are provided for sales or distribution of goods and services to the public, at least one of each type shall have a portion of the counter which is at least 36" in length with a maximum height of 34" above finish floor and located on an accessible route. Exception: In existing buildings where it is determined that providing an accessible counter would create an unreasonable hardship, equivalent facilitation may consist of one of the following: 1. An auxiliary counter, in close proximity, meeting these requirements. may be provided. 2. Provision of a folding shelf attached to the main counter on which an individual with disabilities can write. CBC 11B-904.4 / 36" max high required in ADA 28 CFR Part 36 App A 7.2 Sales and Services Counters, Teller Windows, Information Counters / 2010 ADA Standards 904.4 (CBC more restrictive) Findings - 42" at pass thru services counter window. If these are used by the public it shall comply with this section.
B.
Estimated Cost: $3000
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 18 of 70327
5. Accessible Routes Interior
C N/C Yes No I N/I A/R N/A A
A.
Interior Path of travel shall be free of obstruction and wide enough for a wheelchair (at least 36" wide)
•
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide 36" minimum clear width in accessible path of travel. Every portion of every building in which are installed seats, tables, merchandise, equipment or similar materials shall be provided with aisles leading to an exit. CBC 11B-403 / Every aisle shall not be less than 36" wide if serving only one side, and not less than 44" wide if serving both sides or occupant loads of 10 or more. CBC 11B-403.5.1 Clear Widths, / 28 CFR Part 36 App "A" 4.3 Accessible Routes / ADA 2010 Standards: 403 Walking Surfaces
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 19 of 70328 A.
Kitchen access around center table / Findings - 25-1/2" / 30" clear width ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 20 of 70329
6. Reach Ranges for Operable Parts.
C N/C Yes No I N/I A/R N/A A
A. Reach Range Requirements. •
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 21 of 70330 Comments:
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 22 of 70331 A. 11B-308.2 Forward Reach.
11B-308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward reach shall be 15 inches minimum above the finish floor or ground. 11B-308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches maximum where the reach depth is 20 inches maximum. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum.
11B-308.3 Side Reach.
11B-308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches maximum and the low side reach shall be 15 inches minimum above the finish floor or ground.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 23 of 70332 A. Light switch and thermostat out of reach range. Does not meet "Safe Harbor" of 54" maximum.
B.
Estimated Cost: $500
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 24 of 70333
7. Kitchens & Kitchenettes
C N/C Yes No I N/I A/R N/A A
A. Lavatory heights shall be 29" min and 34" max above finish floor. • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-212.3 Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 11B-606 (Lavatories and Sinks).
EXCEPTION:
1. Mop service or scullery sinks shall not be required to comply with 11B-212.3.
2. Scrub sinks, as defined in California Plumbing Code Section 221.0, shall not be required to comply with 11B-606 (Lavatories and Sinks).
Findings - Provide (1) accessible sink in kitchen that meets section 11B-606. Modification to existing scullery sink not required.
B.
Estimated Cost: $250
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 25 of 70334 8(A) . Men's Restroom Door
C N/C Yes No I N/I A/R N/A A
A.1.
Men's sanitary facility - proper signs (1/4" thick, 12" equilateral triangle / light on dark or dark on light) Permanent Room Identification Sign (Braille) •
B.1.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.1. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • D.1. 5 seconds from 90deg to 12deg from latch. •
E.1.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
F.1.
Maneuvering space of 60" measured from the face of the closed door on the pull side. 48" from push side.
•
G.1.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
H.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 26 of 70335 Comments:
A.1. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 27 of 70336 A.1.
Tactile Sign Not Provided / Geometric sign not provided B.1. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 28 of 70337 C.1. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided.
CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - 26" clear width
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 29 of 70338 D.1.
No Closure Provided
E.1.
No Closure Provided
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 30 of 70339 F.1. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances Findings - 56-1/2" (60" minimum required.)
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 31 of 70340 G.1. 11B-404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate./ 28 CFR Part 36 App. A - 4.13 / ADA 2010 Standards: 404.2.4 Maneuvering Clearances Findings - 14-1/2" strike side clearance
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 32 of 70341 H.1.
Estimated Cost: $3000
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 33 of 70342 8(B) . Women's Restroom Doors
C N/C Yes No I N/I A/R N/A A
A.2.
Women's sanitary facility - proper signs (1/4" thick, 12" circle / light on dark or dark on light)
•
B.2.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.2. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • D.2. 5 seconds from 90deg to 12deg from latch. •
E.2.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
F.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 34 of 70343 Comments:
A.2. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 35 of 70344 A.2.
Tactile Sign Not Provided / Geometric sign not provided A.2. Findings - Incorrect Mounting Location
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 36 of 70345 B.2. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 37 of 70346 C.2. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided.
CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - 27-3/4" clear width
D.2.
No Closure Provided
E.2.
No Closure Provided
F.2.
Estimated Cost: $3000
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 38 of 70347 9(A) . Men's Restroom
This restroom has many violations with all elements and clearances. This restroom will need extensive design to determine the feasibility to meet full and strict compliance for the disabled.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 39 of 70348 C N/C Yes No I N/I A/R N/A A
A.1. Common area public toilet rooms shall be located on an accessible route. • B.1.
Public toilet rooms shall be large enough to accommodate a wheelchair turnaround (60" diameter) or have the required clear floor space. •
C.1. Required clearance at water closet shall be provided. • D.1.
Toilet stall doors shall be at least 32" wide on end doors or 34" on side doors to stalls. 18" strike-side clearance for out swinging doors and 12" for in swinging doors.
•
E.1. Grab Bars shall be provided. •
F.1. Water closet shall be centered 17" to 18" center from side wall. • G.1. Water closet seat cover shall be 17"-19" above finish floor. • H.1.
Toilet tissue dispenser shall be within 7" minimum to 9" to the center of dispenser maximum from the front of water closet 19" minimum from the floor to the outlet of the dispenser and mounted below the grab bar. •
I.1. Clear Floor or Ground Space of Wheelchairs •
J.1. Sinks shall be mounted 18" minimum off the side wall to center of sink. • K.1.
Sinks shall be mounted 34" max from top of rim above finish floor and 17" min from rear wall to front of sink.
•
L.1. Exposed pipes under sinks shall be sufficiently insulated against contact. • M.1.
Mirror shall be 40" max to reflective surface and 74" minimum to the top of the reflective surface above finish floor if provided.
•
N.1.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
O.1.
Accessible urinals shall be min 13-1/2" from wall and 17" max from finish floor to rim.
•
P.1. The lever on the urinal shall be 44" max above finish floor. • Q.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 40 of 70349 Comments:
A.1.
Non accessible door - See Men's Restroom Door section.
B.1. Provide 60" Turning Space in room. A clear floor space measured to a height of 27" above the floor, within the sanitary facility room, of sufficient size to inscribe a circle with a diameter not less than 60" in size. Other than the door to the accessible water closet compartment, a door, in any position, may encroach into the space by not more than 12". CBC 11B-603 Multiple-accommodation toilet facilities. / 28 CFR Part 36 App "A" 4.23 / 2010 ADAS 603 Findings - Not provided in restroom
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 41 of 70350 ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 42 of 70351 C.1. 11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 11B-604.3.11B-604.3.1 Size. Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. A minimum 60 inches wide and 48 inches deep maneuvering space shall be provided in front of the water closet.. ADDAG 91 - In existing facilities a clear floor space shall not be lees than 36" by 48" in front of the water closet. In new facilities (CBC 1984), the wide clear floor space shall be 28" min to any fixture from the edge of the water closet and 32" clear to a wall or partition. In the 91 ADAAG a fixture can be 36" from the side wall. The width from wall to wall shall be 60" minimum.
C.1. Findings - Not provided
D.1. Provide 32" clear width from face of door at 90deg to opposite stop. CBC 1133B.2 Doors / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates / 34" when located on the side of the water closet compartment. CBC 1115B.3.1.4(4.4) 18" strike side clearance shall be 18" on out swings door and 12" on in swings doors. (2010 ADA 604.8.1.2)
Findings - There is no partition door, however the clear width is 23-1/2" wide.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 43 of 70352 E.1. Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Clearance above the tank shall be 1-12" minimum to bottom of grab bar. Bar shall be position above water closet at 12" and 24". 2013 CBC 11B-604.5.2 / 28 CFR Part 36 App. "A" - 4.16.4 Grab Bars / ADA 2010 Standards: 604.5 Grab Bars. Exception: 2010 ADA Standards - 604.5.2 Exception 1 the rear grab bar shall be permitted to be 24" long centered on the water closet.
Where wall space does not permit a 36" grab bar due to a recessed fixture adjacent to the water closet.
Findings - Not Provided or incorrect
H.1. 11B-604.7 Dispensers. Toilet paper dispensers shall comply with 11B-309.4 (Operation) and shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be below the grab bar, 19 inches minimum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. / 28 CFR Part 36 App. "A" 4.16.6 Dispensers
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 44 of 70353 H.1. Findings - Incorrect Mounting Location
I.1. 11B-305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 11B-302 (Floor or Ground Surfaces). Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 11B-305.3 Size. The clear floor or ground space shall be 30 inches minimum by 48 inches minimum. 2013 CBC 11B-305 / 2010 ADA Standards for Accessible Design 305 Clear Floor and Ground Space ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 45 of 70354 I.1.
Findings - 44" / Not Provided at sink
I.1. Findings - 40" / Not Provided at urinal
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 46 of 70355 J.1. Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink. A clear floor space shall be provided for forward approach. CBC 11B 606.6 Findings - 16"
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 47 of 70356 K.1. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-606 / 28 CFR Part 36 App "A" 4.19 / ADAS 2010 - 606
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 48 of 70357 K.1.
Findings - 34-1/2" to top of rim
L.1. Provide insulated wrapping around pipes under sink. Hot water and drainpipes accessible under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. CBC 1115B.4.3.4 Accessible Lavatories / 28 CFR Part 36 App "A" 4.24.6 Exposed Pipes and Surfaces Findings - Exposed
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 49 of 70358 M.1. Findings - 48-1/2" Greater than 40" to reflective surface above finish floor.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 50 of 70359 N.1. Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor. CBC 11B-603.5. / 28 CFR Part 36 App "A" 4.16.6 Dispensers Findings - ( 47" for Towel Dispenser) (No clear floor space and mounted too high Toilet seat covers) ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 51 of 70360 O.1. Prove accessible urinal. Urinals shall be floor mounted, stall type or wall hung. Where one or more wall-hung urinals are provided, at least one with an elongated rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided. CBC 11B-605.2 / 28 CFR Part 36 App "A" 4.18 Urinals / 2010 ADAS 605.2 Findings - 24-1/2" to lip of urinal
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 52 of 70361 P.1. 11B-605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 11B- 309 (Operable Parts) except that the flush control shall be mounted at a maximum height of 44 inches above the finish floor.
Findings - 47" to top of lever
Q.1.
Estimated Costs: $15,000
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 53 of 70362 9(B) . Women's Restroom
This restroom has many violations with all elements and clearances. This restroom will need extensive design to determine the feasibility to meet full and strict compliance for the disabled.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 54 of 70363 C N/C Yes No I N/I A/R N/A A
A.2. Common area public toilet rooms shall be located on an accessible route. • B.2.
Path of Travel shall have no obstacles (phones, fountains, etc.) that protrude more than 4 inches into walkways or corridors between 27" AFF and 80" AFF •
C.2. Required clearance at water closet shall be provided. • D.2. Grab Bars shall be provided. •
E.2. Water closet shall be centered 17" to 18" center from side wall. • F.2. Water closet seat cover shall be 17"-19" above finish floor. • G.2.
Toilet tissue dispenser shall be within 7" minimum to 9" to the center of dispenser maximum from the front of water closet 19" minimum from the floor to the outlet of the dispenser and mounted below the grab bar. •
H.2. Clear Floor or Ground Space of Wheelchairs •
I.2. Sinks shall be mounted 18" minimum off the side wall to center of sink. • J.2. Sinks provided shall have required knee clearance. • K.2. Exposed pipes under sinks shall be sufficiently insulated against contact. • L.2.
Mirror shall be 40" max to reflective surface and 74" minimum to the top of the reflective surface above finish floor if provided.
•
M.2.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
N.2. Coat Hooks shall be 48" maximum to the top of the hook. • O.2.
Light Switch / Outlets Shall be 48" maximum to top of box. 15" to bottom of box for low outlets.
•
P.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.2. Provide an accessible route to accessible toilet facilities. Bathing and toilet facilities that serve buildings, facilities or portions of buildings or facilities that are required by these standards to be accessible to persons with disabilities, shall be on an accessible route. CBC 11B-213 . / 28 CFR Part 36 App "A" 4.23 Bathrooms, Bathing Facilities and Shower Rooms. / ADA 2010 Standards: 213 Toilet Facilities and Bathing Facilities.
Findings - Non accessible door
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 55 of 70364 B.2. 11B-307.2 Protrusion Limits. Objects with leading edges more than 27 inches and not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path. / 28 CFR Part 36 App A: 4.4 Protruding Objects / ADA 2010 Standards: 307 Protruding Objects 11B-307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum and 80 inches maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches, the lowest edge of such sign or obstruction shall be 27 inches maximum or 80 inches minimum above the finish floor or ground.
B.2. Findings - 79-3/4" partition clearance
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 56 of 70365 ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 57 of 70366 C.2. 11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 11B-604.3.11B-604.3.1 Size. Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. A minimum 60 inches wide and 48 inches deep maneuvering space shall be provided in front of the water closet. ADDAG 91 - In existing facilities a clear floor space shall not be less than 36" by 48" in front of the water closet. In new facilities (CBC 1984), the wide clear floor space shall be 28" min to any fixture from the edge of the water closet and 32" clear to a wall or partition. In the 91 ADAAG a fixture can be 36" from the side wall. The width from wall to wall shall be 60" minimum.
C.2. Findings - Not Provided
D.2. Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Clearance above the tank shall be 1-12" minimum to bottom of grab bar. Bar shall be position above water closet at 12" and 24". 2013 CBC 11B-604.5.2 / 28 CFR Part 36 App. "A" - 4.16.4 Grab Bars / ADA 2010 Standards: 604.5 Grab Bars. Exception: 2010 ADA Standards - 604.5.2 Exception 1 the rear grab bar shall be permitted to be 24" long centered on the water closet.
Where wall space does not permit a 36" grab bar due to a recessed fixture adjacent to the water closet.
Findings - Not Provided or incorrect
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 58 of 70367 G.2. 11B-604.7 Dispensers. Toilet paper dispensers shall comply with 11B-309.4 (Operation) and shall be 7 inches minimum and 9 inches maximum in front of the water closet measured to the centerline of the dispenser. The outlet of the dispenser shall be below the grab bar, 19 inches minimum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. / 28 CFR Part 36 App. "A" 4.16.6 Dispensers
G.2. Findings - Incorrect Mounting Location
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 59 of 70368 H.2. 11B-305.2 Floor or Ground Surfaces. Floor or ground surfaces of a clear floor or ground space shall comply with 11B-302 (Floor or Ground Surfaces). Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. 11B-305.3 Size. The clear floor or ground space shall be 30 inches minimum by 48 inches minimum. 2013 CBC 11B-305 / 2010 ADA Standards for Accessible Design 305 Clear Floor and Ground Space ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 60 of 70369 H.2.
Findings - 29-1/2" clear width. 36" minimum clear with side walls greater than 24" from the rear wall.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 61 of 70370 I.2. Lavatories located next to a wall or partition shall be located 18" min from side wall to center of sink. A clear floor space shall be provided for forward approach. CBC 11B 606.6 Findings - 14" to center
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 62 of 70371 J.2. Provide knee clearance at lavatory. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-603 / 28 CFR Part 36 App "A" 4.19 / 2010 ADAS 603 Findings - Bottom underside of sink encroaches on the knee clearance.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 63 of 70372 K.2. Provide insulated wrapping around pipes under sink. Hot water and drainpipes accessible under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. CBC 1115B.4.3.4 Accessible Lavatories / 28 CFR Part 36 App "A" 4.24.6 Exposed Pipes and Surfaces Findings - Exposed
L.2. 11B-603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches maximum above the finish floor or ground. CBC11B-603.3 / 28 CFR Pt36 App A 4.19.6 / 2010 ADA Standards for Accessible Design 6.3.3 Findings - 44-1/2" / Greater than 40" to reflective surface.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 64 of 70373 M.2. Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor. CBC 11B-603.5. / 28 CFR Part 36 App "A" 4.16.6 Dispensers Findings - (59-1/2" Paper Towels)
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 65 of 70374 N.2. 11B-604.8.3 Coat Hooks and Shelves. Coat hooks shall be located within one of the reach ranges specified in 11B-308 (Reach Ranges). Shelves shall be located 40 inches minimum and 48 inches maximum above the finish floor..2010 ADAS 604.3
Findings - 65"
O.2. 11B-308.1.1 Electrical Switches. Controls and switches intended to be used by the occupant of a room or area to control lighting and receptacle outlets, appliances or cooling, heating and ventilating equipment, shall comply with 11B-308 except the low reach shall be measured to the bottom of the outlet box and the high reach shall be measured to the top of the outlet box. / 28 CFR Part 36 App "A" 4.27 C/ 2010 ADAS 309 Findings - 58" / Does not meet "Safe Harbor" at 54" max P.2.
Estimated Costs: $15,000
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 66 of 70375
10. Group A Occupancies - Assembly Halls, Auditoriums,
Theaters
C N/C Yes No I N/I A/R N/A A
A. Assistive-listening systems shall be provided. •
B. Receivers provided shall be equal to 4% of total seating (not less than 2) • C.
If listening system is limited to a specific area, such areas shall be within 50' of the stage with a complete view.
•
D.
Permanent systems are required when accommodating 50 persons or more OR audio-amplification AND they have fixed seating.
•
E.
Portable assistive listening systems used for conference or meeting rooms, the system may serve more than one room.
•
F. Assistive listening system general requirements shall comply with 706. • G. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-219.2 Required Systems. An Assistive Listening System shall be provided in assembly areas, including conference and meeting rooms. ADAS 219.2
EXCEPTION: This section does not apply to systems used exclusively for paging, background music, or a combination of these two uses.
Findings - Not Provided
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 67 of 70376 B. 11B-219.3 Receivers. The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 11B-706.3 (Receiver Hearing-Aid Compatibility). 2010 ADAS 219.3
EXCEPTIONS:
1. Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems.
2. Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by 11B-219.3 to be hearing-aid compatible shall not be required to be provided.
C. 11B-219.4 Location. If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the stage or playing area and shall have a complete view of the stage or playing area.
D. 11B-219.5 Permanent and portable systems. Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating.
If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room. An adequate number of electrical outlets or other supplementary wiring necessary to support a portable assistive-listening system shall be provided.
E. 11B-219.5 Permanent and portable systems. Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating.
If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room. An adequate number of electrical outlets or other supplementary wiring necessary to support a portable assistive-listening system shall be provided.
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 68 of 70377 F. Assistive Listening Systems
11B-706.1 General. Assistive listening systems required in assembly areas, conference and meeting rooms shall comply with 11B-706.
11B-706.2 Receiver Jacks. Receivers required for use with an Assistive Listening System shall include a 1/8 inch standard mono jack.
11B-706.3 Receiver Hearing-Aid Compatibility. Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neckloops. 11B-706.4 Sound Pressure Level. Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB. 11B-706.5 Signal-to-Noise Ratio. The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum.
11B-706.6 Peak Clipping Level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
G.
Estimated Cost: $1000 - $5000
ADA Inspection Plus, LLC
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 69 of 70378 ADA Inspection Plus, LLC
CASp Evaluation Statement
This CASp Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at HB.005 Kiwani's Building South - 2515 Valley Dr., Hermosa Beach, CA 90254. This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply. The areas of the property, dictated by City of Hermosa Beach , and only those areas dictated by City of Hermosa Beach , were inspected for code requirements and addressed in this report under the terms of a CASp Evaluation Agreement. The agreement was signed and agreed upon before the preparation of this report.
HB.005 Kiwani's Building South - 2515 Valley Dr. Page 70 of 70379 Appendix B – ADA Evaluation Reports
A.6 Hermosa Beach Rotary Club (ADA Plus LLC)
380
Program Accessibility Evaluation Report
Inspection Date: 4/8/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
City of Hermosa Beach
HERMOSA BEACH ROTARY CLUB
Property Address:
HB.006 Kiwanis Building North - 2515 Valley
Dr.
Hermosa Beach CA 90254
381
Date: 4/8/2015 Report ID: H.B.006
Property:
HB.006 Kiwanis Building North -
2515 Valley Dr.
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 2 of 66382 IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
PROGRAM ACCESSIBILITY for Title II Facilities.
General. A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
ADA.gov - Public entity. A public entity covered by title II is defined as -- 1) Any State or local government;
2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include -- 1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees;
3) Whether the entity receives significant assistance from the government by provision of property or equipment; and
4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
Relationship to title III. Public entities are not subject to title III of the ADA, which covers only private entities.
Conversely, private entities are not subject to title II. In many situations, however, public entities have a close relationship to private entities that are covered by title III, with the result that certain activities may be at least indirectly affected by both titles.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 3 of 66383 California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
Building Use:
Public Use Building
Age Of building:
Pre ADA Regulations
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 4 of 66384 Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Inspection Scope .....................................................6 2 Ramps......................................................................7 3 Entrance Doors......................................................10 4 Miscellaneous Doors..............................................19 5 Reach Ranges for Operable Parts.........................24 6 Kitchens & Kitchenettes.........................................28 7(A) Men's Restroom Door .......................................32 7(B) Women's Restroom Doors ................................37 8(A) Men's Restroom ................................................43 8(B) Women's Restroom...........................................53 9 Group A Occupancies - Assembly Halls,
Auditoriums, Theaters...............................................63 Agreement ................................................................66 ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 5 of 66385
1. Inspection Scope
C N/C Yes No I N/I A/R N/A A
A. Inspection Scope and Areas. •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
Interior Evaluation including doors, restrooms, kitchen, assembly rooms.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 6 of 66386
2. Ramps
C N/C Yes No I N/I A/R N/A A
A.
Slope of ramp shall not exceed 1:12 (8.33%) running slope and 1:48 (2%) cross slope.
•
B. Required level landings shall be provided (60"x60" Top / 60"x72" Bottom). • C. Pedestrian ramps shall have compliant railings on both sides of ramp. • D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Slopes on ramp shall not exceed 1:12 (8.33%) and maximum 1:48 (2%) cross slope. CBC 11B-405 Slope - / 28 CFR Part 36 App. A - 4.8 Ramps / ADA 2010 Standards: 405 Ramps Findings - 8% at top near door.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 7 of 66387 B. Ramp landings shall provide landings with slopes not exceeding 1:48 (2%) with top landings 60"x 60" minimum.
Intermediate landings width of ramp x 60". Bottom landings width of ramp x 72". Changes in directions require landing 72" long x 60" wide with the 72" in the direction of downward travel. CBC 11B-405.7 / 28 CFR Part 36 App. A - 4.8 Ramps. / ADA 2010 Standards: 405 Ramps
(Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches. Doors, in any position, shall not reduce the minimum dimension of the ramp landing to less than 42 inches. 11B-405.7.5)
Findings - No door landing and no top ramp landings. Ramp continues to door threshold.
Note: Design of a ramp and stairs are required for this area.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 8 of 66388 C. Ramps shall provide hand railing on each side of ramp.. CBC 11B-405.8 Handrails for Ramps / 28 CFR Part 36 App. A - 4.8.5 / ADA 2010 Standards: 405.8 Handrails
Findings - Not Provided
D.
Estimated Cost: $15,000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 9 of 66389
3. Entrance Doors
C N/C Yes No I N/I A/R N/A A
A. Double Leaf Doors shall have at least one active compliant door. • B.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
D.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
E.
Maneuvering space for forward approach shall be 60" measured from the face of the closed door on the pull side. 48" from push side. Slopes shall not exceed 2% for Manual Doors
•
F. Threshold - 1/4" or 1/2" beveled at 1:2 between 1/4" and 1/2" • G. Smooth surface 10" at the bottom of door on the push side. • H.
An EXIT sign with Contracted Grade II Braille shall be placed on the strike side of the interior spaces leading to an accessible Exit.
•
I. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 11B-404.2.3 (Doors, Doorways, and Gates - Clear Width) and 11B- 404.2.4 (Maneuvering Clearances). / ADA 2010 Standards: 404.2.2 Double-Leaf Doors and Gates ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 10 of 66390 B. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 11 of 66391 B.
Door to Activity Area
B.
Door to Meeting Room/Office Area
C.
No Closure Provided
D.
No Closure Provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 12 of 66392 E. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 13 of 66393 E.
Activity Room Entry Doors - 8.8% in level maneuvering space on push side of F. Provide or modify door threshold or raise maneuvering space so that the floor or landing shall not be more than 1/2" lower than the top of the threshold of the doorway. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2. CBC 11B-404.2.5 Thresholds / 28 CFR Part 36 App A: 4.13.8 Thresholds at doorways /ADA 2010 Standards: 404.2.5 Thresholds
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 14 of 66394 F. Entry Doors to Activity Area / Findings - 1-1/2" to top of threshold F. Entry Door to Meeting/Office Area / Findings - 2" to top of threshold ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 15 of 66395 G. Provide a 10" smooth panel on the push side of door or gate. Cap all voids at top of smooth panel if void is present. CBC 11B-404.2.10 / ADA 2010 Standards: 404.2.10 Door and Gate Surfaces (Exception 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor shall not be required to provide smooth surfaces complying with 404.2.10 provided that if added kick plates are installed, cavities created by the kick plates are capped.)
G. Entry Doors to Activity Area / Findings - door stop in 10" smooth portion of door on the push side.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 16 of 66396 H. Provide tactile EXIT sign at exit doors in accordance with CBC 11B-703 Signs / ADA 2010 Standards: 216.4 Means of Egress / No provisions in 28 CFR Pt 36 App A.
Findings - Not provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 17 of 66397 H.
Lighted EXIT from office/ Meeting room area. - Not Provided H. Lighted EXIT from activity room area. - Not Provided I.
Estimated Cost: $5000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 18 of 66398
4. Miscellaneous Doors
C N/C Yes No I N/I A/R N/A A
A. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • B.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 19 of 66399 A.
Findings - 29" clear width / This Door may not be required to be accessible.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 20 of 66400 A.
Door to kitchen accessed through activity area / Findings - 28" clear width B. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
Note: Doors to be used by the public shall be accessible.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 21 of 66401 B.
Misc. Doors throughout the facility have twist type door knobs and shall be replaced with lever type handles.
B. Doors to kitchen / Only one accessible door required ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 22 of 66402 C. 11B-404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate./ 28 CFR Part 36 App. A - 4.13 / ADA 2010 Standards: 404.2.4 Maneuvering Clearances C.
Kitchen door accessed through activity area - Findings - 9" strike side clearance D.
Estimated Cost: $4000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 23 of 66403
5. Reach Ranges for Operable Parts.
C N/C Yes No I N/I A/R N/A A
A. Reach Range Requirements. •
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 24 of 66404 Comments:
A. 11B-308.2 Forward Reach.
11B-308.2.1 Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches maximum and the low forward reach shall be 15 inches minimum above the finish floor or ground. 11B-308.2.2 Obstructed High Reach. Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48 inches maximum where the reach depth is 20 inches maximum. Where the reach depth exceeds 20 inches, the high forward reach shall be 44 inches maximum and the reach depth shall be 25 inches maximum.
11B-308.3 Side Reach.
11B-308.3.1 Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches maximum and the low side reach shall be 15 inches minimum above the finish floor or ground.
Does NOT meet "Safe Harbor" Requirements of 54" to top if installed before March 15, 2012.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 25 of 66405 A. Fire Extinguisher's are required to be at 48" to handle for current code. It is recommended to lower top of operable part to 48" above finish floor.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 26 of 66406 A.
Outlet out of reach range
A.
Thermostat out of reach range
B.
Estimated Cost: $1500
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 27 of 66407
6. Kitchens & Kitchenettes
C N/C Yes No I N/I A/R N/A A
A. Lavatory heights shall be 29" min and 34" max above finish floor. • B. Sinks provided shall have required knee clearance. • C. Ranges or cook-tops control locations shall not require reaching over burners. • D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 28 of 66408 Comments:
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 29 of 66409 A. 11B-212.3 Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 11B-606 (Lavatories and Sinks). 11B-804.4 Sinks. Sinks shall comply with 11B-606 (Lavatories and Sinks).
All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge.
In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-606 / 28 CFR Part 36 App "A"
4.19 / ADAS 2010 - 606
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 30 of 66410 Findings - No accessible sink provided. Install additional accessible sink if possible. If not, this sink shall meet current code requirements.
C. 11B-804.6.4 Range or Cooktop. Where a forward approach is provided, the clear floor or ground space shall provide knee and toe clearance complying with 11B- 306 (Knee and Toe Clearance). Where knee and toe space is provided, the underside of the range or cooktop shall be insulated or otherwise configured to prevent burns, abrasions, or electrical shock. The location of controls shall not require reaching across burners.
Findings - Controls require reaching over burners.
D.
Estimated Cost: $4000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 31 of 66411 7(A) . Men's Restroom Door
This restroom door has many violations. Design and major modifications required for door and restroom to meet accessibility requirements.
C N/C Yes No I N/I A/R N/A A
A.1.
Men's sanitary facility - proper signs (1/4" thick, 12" equilateral triangle / light on dark or dark on light) Permanent Room Identification Sign (Braille) •
B.1.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.1. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • D.1.
Maneuvering space of 60" measured from the face of the closed door on the pull side. 48" from push side.
•
E.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 32 of 66412 Comments:
A.1. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 33 of 66413 A.1.
Tactile Sign Not Provided / Geometric sign not provided B.1. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 34 of 66414 C.1. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided.
CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - 27" clear width
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 35 of 66415 D.1. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances Findings - 37" on pull side / Less than 60" on pull side of door. / Less than 18" on strike side clearances on the pull side of door.
E.1.
Estimated Cost: $2500
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 36 of 66416 7(B) . Women's Restroom Doors
This restroom door has many violations. Design and major modifications required for door and restroom to meet accessibility requirements.
C N/C Yes No I N/I A/R N/A A
A.2.
Women's sanitary facility - proper signs (1/4" thick, 12" circle / light on dark or dark on light)
•
B.2.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
C.2. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • D.2. 5 seconds from 90deg to 12deg from latch. •
E.2.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
F.2.
Maneuvering space of 60" measured from the face of the closed door on the pull side. 48" from push side.
•
G.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 37 of 66417 Comments:
A.2. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 38 of 66418 A.2.
Tactile Sign Not Provided / Geometric sign not provided B.2. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 39 of 66419 C.2. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided.
CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - 27" clear width
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 40 of 66420 C.2.
Interior door passage is less than 32" minimum clear width. / Findings - 30" D.2.
No Closure Provided
E.2.
No Closure Provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 41 of 66421 F.2. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances Findings - 34" on pull side of door.
G.2.
Estimated Cost: $2500
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 42 of 66422 8(A) . Men's Restroom
This restroom has many violations. Design and major modifications required for door and restroom to meet accessibility requirements.
Some violation not inspected due to severity of all violations as a hole.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 43 of 66423 C N/C Yes No I N/I A/R N/A A
A.1. Common area public toilet rooms shall be located on an accessible route. • B.1.
Public toilet rooms shall be large enough to accommodate a wheelchair turnaround (60" diameter) or have the required clear floor space. •
C.1. Required clearance at water closet shall be provided. • D.1. Grab Bars shall be provided. •
E.1. Water closet shall be centered 17" to 18" center from side wall. • F.1. Water closet seat cover shall be 17"-19" above finish floor. • G.1.
Toilet tissue dispenser shall be within 7" minimum to 9" to the center of dispenser maximum from the front of water closet 19" minimum from the floor to the outlet of the dispenser and mounted below the grab bar. •
H.1. Sinks provided shall have required knee clearance. • I.1. Exposed pipes under sinks shall be sufficiently insulated against contact. • J.1.
Mirror shall be 40" max to reflective surface and 74" minimum to the top of the reflective surface above finish floor if provided.
•
K.1.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
L.1.
Accessible urinals shall be min 13-1/2" from wall and 17" max from finish floor to rim.
•
M.1. The lever on the urinal shall be 44" max above finish floor. • N.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.1. Provide an accessible route to accessible toilet facilities. Bathing and toilet facilities that serve buildings, facilities or portions of buildings or facilities that are required by these standards to be accessible to persons with disabilities, shall be on an accessible route. CBC 11B-213 . / 28 CFR Part 36 App "A" 4.23 Bathrooms, Bathing Facilities and Shower Rooms. / ADA 2010 Standards: 213 Toilet Facilities and Bathing Facilities.
Findings - See Restroom Door section
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 44 of 66424 B.1. Must comply with single accommodation toilet facility. There shall be sufficient space in the toilet room for a wheel chair measuring 30" wide by 48" long to enter the room and permit the door to close. There shall be in the room a clear floor space of at least 60" in diameter, or a T-Shaped space complying with T-Shaped Detail. No door shall encroach into this space for more than 12". CBC 11B-603 / ADA 2010 Standards: 603 Toilet and Bathing Rooms
Findings - Not Provided - Very small restroom
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 45 of 66425 ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 46 of 66426 C.1. 11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 11B-604.3.11B-604.3.1 Size. Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. A minimum 60 inches wide and 48 inches deep maneuvering space shall be provided in front of the water closet. ADDAG 91 - In existing facilities a clear floor space shall not be less than 36" by 48" in front of the water closet. In new facilities (CBC 1984), the wide clear floor space shall be 28" min to any fixture from the edge of the water closet and 32" clear to a wall or partition. In the 91 ADAAG a fixture can be 36" from the side wall. The width from wall to wall shall be 60" minimum.
Findings - Not Provided
D.1. Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Clearance above the tank shall be 1-12" minimum to bottom of grab bar. Bar shall be position above water closet at 12" and 24". 2013 CBC 11B-604.5.2 / 28 CFR Part 36 App. "A" - 4.16.4 Grab Bars / ADA 2010 Standards: 604.5 Grab Bars. Exception: 2010 ADA Standards - 604.5.2 Exception 1 the rear grab bar shall be permitted to be 24" long centered on the water closet.
Where wall space does not permit a 36" grab bar due to a recessed fixture adjacent to the water closet.
Findings - Not Provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 47 of 66427 E.1. The centerline of the water closet fixture shall be centered 17" to 18" from the side wall or partition. In Ambulatory compartments, the center of the water closet shall be located 17" to 19" from the side wall. CBC 1115B.4.1 Accessible Water Closet / 28 CFR Part 36 App "A" 4.16 Water Closets / 2010 ADA Standards for Accessible Design 604.2
Findings - No clearances provided
F.1. Install water closet with a seat height of 17" - 19" above finish floor. The height of accessible water closet shall be a minimum of 17" and a maximum of 19" measured to the top of a maximum 2" high toilet seat. Exception: A 3" toilet seat shall be permitted only in alterations where the existing fixture is less than 15" high. CBC 1115B.4.1.4 Accessible Water Closet. / 28 CFR Part 36 App "A" Water Closets / ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 48 of 66428 H.1. Provide knee clearance at lavatory. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-603 / 28 CFR Part 36 App "A" 4.19 / 2010 ADAS 603 Findings - Pedestal sinks are not accessible - knee clearance not provided ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 49 of 66429 J.1. 11B-603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches maximum above the finish floor or ground. CBC11B-603.3 / 28 CFR Pt36 App A 4.19.6 / 2010 ADA Standards for Accessible Design 6.3.3 Findings - 48-1/2" / Greater than 40" to reflective surface.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 50 of 66430 K.1. Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor. CBC 11B-603.5. / 28 CFR Part 36 App "A" 4.16.6 Dispensers Findings - (48" for Towel Dispenser)
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 51 of 66431 L.1. Prove accessible urinal. Urinals shall be floor mounted, stall type or wall hung. Where one or more wall-hung urinals are provided, at least one with an elongated rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided. CBC 11B-605.2 / 28 CFR Part 36 App "A" 4.18 Urinals / 2010 ADAS 605.2 Findings - 26-1/2" to rim
M.1. 11B-605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 11B- 309 (Operable Parts) except that the flush control shall be mounted at a maximum height of 44 inches above the finish floor.
Findings - 51"
N.1.
Estimated Costs: $15,000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 52 of 66432 8(B) . Women's Restroom
This restroom door has many violations. Design and major modifications required for door and restroom to meet accessibility requirements.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 53 of 66433 C N/C Yes No I N/I A/R N/A A
A.2. Common area public toilet rooms shall be located on an accessible route. • B.2.
Path of Travel shall have no obstacles (phones, fountains, etc.) that protrude more than 4 inches into walkways or corridors between 27" AFF and 80" AFF •
C.2.
Public toilet rooms shall be large enough to accommodate a wheelchair turnaround (60" diameter) or have the required clear floor space. •
D.2. Required clearance at water closet shall be provided. • E.2. Grab Bars shall be provided. •
F.2. Water closet shall be centered 17" to 18" center from side wall. • G.2. Water closet seat cover shall be 17"-19" above finish floor. • H.2.
Toilet tissue dispenser shall be within 7" minimum to 9" to the center of dispenser maximum from the front of water closet 19" minimum from the floor to the outlet of the dispenser and mounted below the grab bar. •
I.2. Sinks provided shall have required knee clearance. • J.2.
Faucet controls and other operable parts shall be operable with one hand without grasping, pinching or twisting with 5lbs max force to activate. •
K.2.
Mirror shall be 40" max to reflective surface and 74" minimum to the top of the reflective surface above finish floor if provided.
•
L.2.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
M.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.2. Provide an accessible route to accessible toilet facilities. Bathing and toilet facilities that serve buildings, facilities or portions of buildings or facilities that are required by these standards to be accessible to persons with disabilities, shall be on an accessible route. CBC 11B-213 . / 28 CFR Part 36 App "A" 4.23 Bathrooms, Bathing Facilities and Shower Rooms. / ADA 2010 Standards: 213 Toilet Facilities and Bathing Facilities.
Findings - See Restroom Doors section.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 54 of 66434 B.2. 11B-307.2 Protrusion Limits. Objects with leading edges more than 27 inches and not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path. / 28 CFR Part 36 App A: 4.4 Protruding Objects / ADA 2010 Standards: 307 Protruding Objects 11B-307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum and 80 inches maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches, the lowest edge of such sign or obstruction shall be 27 inches maximum or 80 inches minimum above the finish floor or ground.
B.2. Overhead obstruction / Findings - 77-1/2"
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 55 of 66435 C.2. Must comply with single accommodation toilet facility. There shall be sufficient space in the toilet room for a wheel chair measuring 30" wide by 48" long to enter the room and permit the door to close. There shall be in the room a clear floor space of at least 60" in diameter, or a T-Shaped space complying with T-Shaped Detail. No door shall encroach into this space for more than 12". CBC 11B-603 / ADA 2010 Standards: 603 Toilet and Bathing Rooms
Findings - Very small restroom
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 56 of 66436 ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 57 of 66437 D.2. 11B-604.3 Clearance. Clearances around water closets and in toilet compartments shall comply with 11B-604.3.11B-604.3.1 Size. Clearance around a water closet shall be 60 inches minimum measured perpendicular from the side wall and 56 inches minimum measured perpendicular from the rear wall. A minimum 60 inches wide and 48 inches deep maneuvering space shall be provided in front of the water closet. ADDAG 91 - In existing facilities a clear floor space shall not be less than 36" by 48" in front of the water closet. In new facilities (CBC 1984), the wide clear floor space shall be 28" min to any fixture from the edge of the water closet and 32" clear to a wall or partition. In the 91 ADAAG a fixture can be 36" from the side wall. The width from wall to wall shall be 60" minimum.
Findings - Not Provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 58 of 66438 E.2. Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Clearance above the tank shall be 1-12" minimum to bottom of grab bar. Bar shall be position above water closet at 12" and 24". 2013 CBC 11B-604.5.2 / 28 CFR Part 36 App. "A" - 4.16.4 Grab Bars / ADA 2010 Standards: 604.5 Grab Bars. Exception: 2010 ADA Standards - 604.5.2 Exception 1 the rear grab bar shall be permitted to be 24" long centered on the water closet.
Where wall space does not permit a 36" grab bar due to a recessed fixture adjacent to the water closet.
Findings - Not Provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 59 of 66439 I.2. Provide knee clearance at lavatory. Lavatories located adjacent to a wall or partition shall be minimum 18" to centerline of fixture from side wall or partition. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge. In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-603 / 28 CFR Part 36 App "A" 4.19 / 2010 ADAS 603 Findings - Pedestal sinks are not accessible - knee clearance not provided ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 60 of 66440 J.2. Operable Parts shall not require tight grasping, pinching or twisting. Control shall be operable with one hand and shall not require tight grasping, pinching or twisting. CBC 11B-309.4 Findings - twist type faucet controls.
K.2. 11B-603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches maximum above the finish floor or ground. CBC11B-603.3 / 28 CFR Pt36 App A 4.19.6 / 2010 ADA Standards for Accessible Design 6.3.3 Findings - 48" / Greater than 40" to reflective surface.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 61 of 66441 L.2. Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor. CBC 11B-603.5. / 28 CFR Part 36 App "A" 4.16.6 Dispensers Findings - (47" for Towel Dispenser)
M.2.
Estimated Costs: $15,000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 62 of 66442
9. Group A Occupancies - Assembly Halls, Auditoriums,
Theaters
C N/C Yes No I N/I A/R N/A A
A. Assistive-listening systems shall be provided. •
B. Receivers provided shall be equal to 4% of total seating (not less than 2) • C.
If listening system is limited to a specific area, such areas shall be within 50' of the stage with a complete view.
•
D.
Permanent systems are required when accomadating 50 persons or more OR audio-amplification AND they have fixed seating.
•
E.
Portable assistive listening systems used for conference or meeting rooms, the system may serve more than one room.
•
F. Assistive listening system general requirements shall comply with 706. • G. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-219 Assistive Listening Systems
11B-219.1 General. Assistive listening systems shall be provided in accordance with 11B-219 and shall comply with 11B-706 (Assistive Listening Systems).
11B-219.2 Required Systems. An Assistive Listening System shall be provided in assembly areas, including conference and meeting rooms.
EXCEPTION: This section does not apply to systems used exclusively for paging, background music, or a combination of these two uses.
Findings - Not Provided
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 63 of 66443 B. 11B-219.3 Receivers. The minimum number of receivers to be provided shall be equal to 4 percent of the total number of seats, but in no case less than two. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible in accordance with 11B-706.3 (Receiver Hearing-Aid Compatibility). 2010 ADAS 219.3
EXCEPTIONS:
1. Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems.
2. Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required by 11B-219.3 to be hearing-aid compatible shall not be required to be provided.
C. 11B-219.4 Location. If the assistive-listening system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the stage or playing area and shall have a complete view of the stage or playing area.
D. 11B-219.5 Permanent and portable systems. Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating.
If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room. An adequate number of electrical outlets or other supplementary wiring necessary to support a portable assistive-listening system shall be provided.
E. 11B-219.5 Permanent and portable systems. Permanently installed assistive-listening systems are required in areas if (1) they accommodate at least 50 persons or if they have audio-amplification systems, and (2) they have fixed seating.
If portable assistive-listening systems are used for conference or meeting rooms, the system may serve more than one room. An adequate number of electrical outlets or other supplementary wiring necessary to support a portable assistive-listening system shall be provided.
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 64 of 66444 F. Assistive Listening Systems
11B-706.1 General. Assistive listening systems required in assembly areas, conference and meeting rooms shall comply with 11B-706.
11B-706.2 Receiver Jacks. Receivers required for use with an Assistive Listening System shall include a 1/8 inch standard mono jack.
11B-706.3 Receiver Hearing-Aid Compatibility. Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neckloops. 11B-706.4 Sound Pressure Level. Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB. 11B-706.5 Signal-to-Noise Ratio. The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum.
11B-706.6 Peak Clipping Level. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech.
G.
Estimated Cost: $1000 - $5000
ADA Inspection Plus, LLC
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 65 of 66445 ADA Inspection Plus, LLC
CASp Evaluation Statement
This CASp Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at HB.006 Kiwanis Building North - 2515 Valley Dr., Hermosa Beach, CA 90254.
This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply. The areas of the property, dictated by City of Hermosa Beach , and only those areas dictated by City of Hermosa Beach , were inspected for code requirements and addressed in this report under the terms of a CASp Evaluation Agreement. The agreement was signed and agreed upon before the preparation of this report.
HB.006 Kiwanis Building North - 2515 Valley Dr. Page 66 of 66446 Appendix B – ADA Evaluation Reports
A.7 Fire Department (ADA Plus LLC)
447
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
Fire Department
Hermosa Beach CA 90254
Inspection Date: 4/21/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
448
Date: 4/21/2015 Report ID: H.B.007
Property:
Fire Department
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
ADA Inspection Plus, LLC
Fire Department Page 2 of 45449
IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
PROGRAM ACCESSIBILITY for Title II Facilities.
General. A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
ADA.gov - Public entity. A public entity covered by title II is defined as -- 1) Any State or local government;
2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include -- 1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees;
3) Whether the entity receives significant assistance from the government by provision of property or equipment; and
4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
Relationship to title III. Public entities are not subject to title III of the ADA, which covers only private entities.
Conversely, private entities are not subject to title II. In many situations, however, public entities have a close relationship to private entities that are covered by title III, with the result that certain activities may be at least indirectly affected by both titles.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
ADA Inspection Plus, LLC
Fire Department Page 3 of 45450
California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
Building Use:
Fire Station
Age Of building:
Pre ADA Regulations
ADA Inspection Plus, LLC
Fire Department Page 4 of 45451
Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Inspection Scope .....................................................6 2 Site Arrival Points.....................................................7 3 Accessible Routes Exterior......................................8 4 Stairways ...............................................................11 5 Entrance Doors......................................................15 6 Miscellaneous Doors..............................................19 7 Service Counters ...................................................24 8 Accessible Routes Interior .....................................26 9 Kitchens & Kitchenettes.........................................28 10 Restrooms............................................................31 11 Unisex Restroom Door.........................................32 12 Unisex Restroom .................................................36 Agreement ................................................................45 ADA Inspection Plus, LLC
Fire Department Page 5 of 45452
1. Inspection Scope
C N/C Yes No I N/I A/R N/A A
A. Inspection Scope and Areas. •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
The entire fire station including doors, restrooms, living quarters, kitchens and locker rooms were inspected for accessibility.
NOTE: Only those areas where the public has access to are required to meet accessibility code requirements for the ADA.
The Estimated Cost for compliance beyond the requirements set forth in the ADA are advisory only and not required to be modified.
ADA Inspection Plus, LLC
Fire Department Page 6 of 45453
2. Site Arrival Points
C N/C Yes No I N/I A/R N/A A
A.
At least one accessible route shall be provided within the boundary of the site from public transportation stops, accessible parking spaces, passenger loading zones, if provided, and public streets and sidewalks.
•
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
Access Provided
ADA Inspection Plus, LLC
Fire Department Page 7 of 45454
3. Accessible Routes Exterior
C N/C Yes No I N/I A/R N/A A
A.
Path of Travel shall have no obstacles (phones, fountains, etc.) that protrude more than 4 inches into walkways or corridors between 27" AFF and 80" AFF •
B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-307.2 Protrusion Limits. Objects with leading edges more than 27 inches and not more than 80 inches above the finish floor or ground shall protrude 4 inches maximum horizontally into the circulation path. / 28 CFR Part 36 App A: 4.4 Protruding Objects / ADA 2010 Standards: 307 Protruding Objects 11B-307.3 Post-Mounted Objects. Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches maximum when located 27 inches minimum and 80 inches maximum above the finish floor or ground. Where a sign or other obstruction is mounted between posts or pylons and the clear distance between the posts or pylons is greater than 12 inches, the lowest edge of such sign or obstruction shall be 27 inches maximum or 80 inches minimum above the finish floor or ground.
ADA Inspection Plus, LLC
Fire Department Page 8 of 45455
A. Emergency Fire Alarm mechanism violates obstacle requirements. Moving it may violate other requirements set forth in City Codes. See Estimated Cost for proposed solution.
Findings - Greater than 4" from Wall / More than 27" from floor ADA Inspection Plus, LLC
Fire Department Page 9 of 45456
B.
Estimated Costs: Unknown & unclear if feasible to do so. $500 for proposed solution:
Proposed solution is to add something under the unit to 27" minimum from the concrete surface.
ADA Inspection Plus, LLC
Fire Department Page 10 of 45457
4. Stairways
Stairs to the second floor are not required to be accessible because the public has no access to second floor. The second floor is dedicated to living and sleeping quarters for the employees only. No action required unless altered or modified. Alterations shall meet current code requirements.
C N/C Yes No I N/I A/R N/A A
A. Risers shall be no less than 4" or greater than 7". • B.
Stairs shall have closed risers. (1/2" between exterior riser and tread is acceptable)
•
C. Hand Railings required on each side of stairs. •
D. Stairs have a stripe on the treads (1" from nose, 2"-4" stripe the width of tread) • E. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Fire Department Page 11 of 45458
Comments:
A. 11B-504.2 Treads and Risers. All steps on a flight of stairs shall have uniform riser heights and uniform tread depths. Risers shall be 4 inches high minimum and 7 inches high maximum. Treads shall be 11 inches deep minimum. 11B-504.3 Open Risers. Open risers are not permitted.. 2010 ADA Standards - 504.2 Treads and Risers Findings - 7-3/4" riser heights
Note: No Action required
ADA Inspection Plus, LLC
Fire Department Page 12 of 45459
B. 11B-504.3 Open Risers. Open risers are not permitted. EXCEPTIONS: 1. On exterior stairways, an opening of not more than 1/2 inch may be permitted between the base of the riser and the tread. 2. On exterior stairways, risers constructed of grating containing openings of not more than 1/2 inch may be permitted.
Findings - Open Risers
Note: No action required.
C. 11B-505.2 Where Required. Handrails shall be provided on both sides of stairs and ramps./ 2010 ADA Standards 504 Stairways, 504.6 Handrails.
Findings - No Handrailing provided
Note: Not required unless modified or altered.
ADA Inspection Plus, LLC
Fire Department Page 13 of 45460
D. 11B-504.4.1 Contrasting Stripe. Interior stairs shall have the upper approach and lower tread marked by a stripe providing clear visual contrast. Exterior stairs shall have the upper approach and all treads marked by a stripe providing clear visual contrast. The stripe shall be a minimum of 2 inches wide to a maximum of 4 inches wide placed parallel to, and not more than 1 inch from, the nose of the step or upper approach. The stripe shall extend the full width of the step or upper approach and shall be of material that is at least as slip resistant as the other treads of the stair. A painted stripe shall be acceptable. Grooves shall not be used to satisfy this requirement.
Findings - Not Provided
Note: Not required unless altered or modified.
E.
Not required - If the City choose to alter these stairs to meet accessibility requirements, the estimated cost would be around $15000-20000
ADA Inspection Plus, LLC
Fire Department Page 14 of 45461
5. Entrance Doors
C N/C Yes No I N/I A/R N/A A
A.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
B.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
C.
Maneuvering space for forward approach shall be 60" measured from the face of the closed door on the pull side. 48" from push side. Slopes shall not exceed 2% for Manual Doors
•
D. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Fire Department Page 15 of 45462
Comments:
B. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware whichever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
Findings - 15lbs of pressure
ADA Inspection Plus, LLC
Fire Department Page 16 of 45463
C. The floor or ground space within the required clearances shall be level and clear. CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
Fire Department Page 17 of 45464
C.
Exterior door landings exceed 2% max in all directions.
Findings - 4.5%
D.
Estimated Cost: $2500
ADA Inspection Plus, LLC
Fire Department Page 18 of 45465
6. Miscellaneous Doors
These doors are not accessed by the public and not required to meet current accessibility requirements unless modified or altered.
C N/C Yes No I N/I A/R N/A A
A.
Door Hardware (lever/push type hardware no twisting required, and mounted between 30" and 44" above the floor)
•
B.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest. (15lbs for panic hardware release) •
C.
Fire door pull/push force 15lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
D.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
E. Threshold - 1/4" or 1/2" beveled at 1:2 between 1/4" and 1/2" • F. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide door hardware mounted between 34" and 44" above finish floor. Hardware shall be easy to grasp with one hand and shall not be required to twist with the wrist, grasp tightly or does not require tight pinching. 28 CFR Part 36 App. A - 4.13.9 / ADA 2010 Standards: 404.2.7 Door and Gate Hardware (CBC More Restrictive) 2013 CBC 11B-404-2-7
Findings - Twist Type door knob
ADA Inspection Plus, LLC
Fire Department Page 19 of 45466
A. Door from garage to living quarters and office.
B. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware whichever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
B. Door from garage to living quarters and office area. 8lbs. of pressure ADA Inspection Plus, LLC
Fire Department Page 20 of 45467
D. 11B-404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate./ 28 CFR Part 36 App. A - 4.13 / ADA 2010 Standards: 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
Fire Department Page 21 of 45468
D.
Door from garage to living quarters and office area. Findings - 4" strike side clearance on pull side of door.
ADA Inspection Plus, LLC
Fire Department Page 22 of 45469
E. Provide or modify door threshold or raise maneuvering space so that the floor or landing shall not be more than 1/2" lower than the top of the threshold of the doorway. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2. CBC 11B-404.2.5 Thresholds / 28 CFR Part 36 App A: 4.13.8 Thresholds at doorways /ADA 2010 Standards: 404.2.5 Thresholds
Findings - Exterior and/or interior door maneuvering space is greater than 1/2 in. maximum for top of threshold to maneuvering space. Sliding door are included.
Note: Not required to be accessible unless modified or altered.
F.
Estimated Cost: $1500
Note: No Action Required. Information only
ADA Inspection Plus, LLC
Fire Department Page 23 of 45470
7. Service Counters
This counter may not need modifications unless transactions of any kind take place across the counter.
C N/C Yes No I N/I A/R N/A A
A. Counter top shall be 36" minimum width and 28" to 34" high maximum. • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide or modify sales or service counter to 28" minimum to 34" maximum height and 36" minimum long. Where counters have cash registers and are provided for sales or distribution of goods and services to the public, at least one of each type shall have a portion of the counter which is at least 36" in length with a maximum height of 34" above finish floor and located on an accessible route. Exception: In existing buildings where it is determined that providing an accessible counter would create an unreasonable hardship, equivalent facilitation may consist of one of the following: 1. An auxiliary counter, in close proximity, meeting these requirements, may be provided. 2. Provision of a folding shelf attached to the main counter on which an individual with disabilities can write. CBC 11B-904.4 / 36" max high required in ADA 28 CFR Part 36 App A 7.2 Sales and Services Counters, Teller Windows, Information Counters / 2010 ADA Standards 904.4 (CBC more restrictive) ADA Inspection Plus, LLC
Fire Department Page 24 of 45471
A. Findings - 38-1/2" to top of counter. If the public does any kind of transaction including informations exchange at this counter, then it shall comply.
B.
Estimated Cost: $500 to provide a counter at 34" maximum above finish floor.
ADA Inspection Plus, LLC
Fire Department Page 25 of 45472
8. Accessible Routes Interior
C N/C Yes No I N/I A/R N/A A
A.
Interior Path of travel shall be free of obstruction and wide enough for a wheelchair (at least 36" wide)
•
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide 36" minimum clear width in accessible path of travel. Every portion of every building in which are installed seats, tables, merchandise, equipment or similar materials shall be provided with aisles leading to an exit. CBC 11B-403 / Every aisle shall not be less than 36" wide if serving only one side, and not less than 44" wide if serving both sides or occupant loads of 10 or more. CBC 11B-403.5.1 Clear Widths, / 28 CFR Part 36 App "A" 4.3 Accessible Routes / ADA 2010 Standards: 403 Walking Surfaces
ADA Inspection Plus, LLC
Fire Department Page 26 of 45473
A. Areas of accessible routes throughout the facility for employees shall have a minimum width of 36" Findings - Locations less than 36" minimum clear width.
ADA Inspection Plus, LLC
Fire Department Page 27 of 45474
9. Kitchens & Kitchenettes
This kitchen is not required to meet current accessibility codes and requirements set forth in the ADA.
No action required unless an alteration or a modification is performed. New construction and alteration shall meet current accessibility code requirements.
Any violation Found and/or estimated cost for remediation is for information only.
C N/C Yes No I N/I A/R N/A A
A. Lavatory heights shall be 29" min and 34" max above finish floor. • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Fire Department Page 28 of 45475
Comments:
A. A. 11B- 212.3 Sinks. Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 11B-606 (Lavatories and Sinks). 11B- 804.4 Sinks. Sinks shall comply with 11B-606 (Lavatories and Sinks).
All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor with a vertical clearance measured from the bottom of the apron or the outside bottom edge of the lavatory of 29" reducing to 27" at a point located 8" back from the front edge.
In addition a 9" high toe clearance must be provided extending back toward the wall to a distance 6" from the back wall. The toe clearance space must be free of equipment or obstructions. CBC 11B-606 / 28 CFR Part 36 App "A"
4.19 / ADAS 2010 - 606
A. Adding an additional sink in a different location within the area would be recommended if the city were to choose to make accessible for an employee.
ADA Inspection Plus, LLC
Fire Department Page 29 of 45476
B.
Estimated Cost: $2500 / Not required
ADA Inspection Plus, LLC
Fire Department Page 30 of 45477
10. Restrooms
Restrooms on the second level are not required to meet current accessibility codes and requirements. All elements on the second floor are not required to meet current codes.
They were inspected briefly and were found to have multiple severe violations if they were provided for the general public.
C N/C Yes No I N/I A/R N/A A
A. Common area public toilet rooms shall be located on an accessible route. • B. Required clearance at water closet shall be provided. • C. Grab Bars shall be provided. •
D. Water closet shall be centered 17" to 18" center from side wall. • E. Water closet seat cover shall be 17"-19" above finish floor. • F. Sinks provided shall have required knee clearance. • G. Mirror shall be 40" max above finish floor if provided. • H. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. No elevator to second floor - No action required
H.
No Action Required.
ADA Inspection Plus, LLC
Fire Department Page 31 of 45478
11. Unisex Restroom Door
Ground level restroom. - Not for public use and not required to meet current ADA codes and requirements.
This section - Information Only
C N/C Yes No I N/I A/R N/A A
A.
Unisex sanitary facilities - proper signs (1/4" thick 12" circle with a 1/4" thick triangle 12" superimposed in the circle. Circle shall be contrasting color to the triangle.)
•
B.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
C.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
D.
Fire door pull/push force 15lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
E.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
F. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Fire Department Page 32 of 45479
Comments:
A. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
Fire Department Page 33 of 45480
A.
Findings - Geometric sign on door not provided
Findings - Missing Tactile Sign on wall
Note: No Action Required
B. Adjust or provide door closure so that from an opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door.CBC 11B-404.2.8.1 / 28 CFR Part 36 App. A - 4.13.10 / 2010 ADAS-404.2.8.1 / Spring hinges are 70deg to closed position in 1.5 seconds minimum) Findings - 3 Seconds 90-12
ADA Inspection Plus, LLC
Fire Department Page 34 of 45481
C. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware whichever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
Findings - 15lbs of pressure
E. 11B-404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate./ 28 CFR Part 36 App. A - 4.13 / ADA 2010 Standards: 404.2.4 Maneuvering Clearances Findings - 13" strike side clearance (18" min required) F.
Estimated Cost: $250
Note: No Action Required
ADA Inspection Plus, LLC
Fire Department Page 35 of 45482
12. Unisex Restroom
Restroom on the ground level are not for public use and are not required to meet current accessibility codes and requirements.
No action required unless an alteration or a modification is performed. New construction and alteration shall meet current accessibility code requirements.
Any violation Found and/or estimated cost for remediation is for information only.
C N/C Yes No I N/I A/R N/A A
A. Grab Bars shall be provided. •
B. Water closet seat cover shall be 17"-19" above finish floor. • C.
Sinks shall be mounted 34" max from top of rim above finish floor and 17" min from rear wall to front of sink.
•
D. Exposed pipes under sinks shall be sufficiently insulated against contact. • E.
The accessible urinal shall have a clear floor space 30" by 48" forward approach.
•
F.
Accessible urinals shall be min 14" and max 17" from rear wall and 17" max from finish floor to rim.
•
G. The lever on the urinal shall be 44" max above finish floor. • H. Mirror shall be 40" max above finish floor if provided. • I.
Restroom Accessories Shall be no higher than 40" to operable parts. All accessories shall have clear floor space 30"x48".
•
J. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Fire Department Page 36 of 45483
Comments:
A. Grab Bars shall be mounted 33" to 36" measured to the top of the grab bar. Clearance above the tank shall be 1-12" minimum to bottom of grab bar. Bar shall be position above water closet at 12" and 24". 2013 CBC 11B-604.5.2 / 28 CFR Part 36 App. "A" - 4.16.4 Grab Bars / ADA 2010 Standards: 604.5 Grab Bars. Exception: 2010 ADA Standards - 604.5.2 Exception 1 the rear grab bar shall be permitted to be 24" long centered on the water closet.
Where wall space does not permit a 36" grab bar due to a recessed fixture, adjacent to the water closet.
Findings - Not Provided
Note: No Action Required
ADA Inspection Plus, LLC
Fire Department Page 37 of 45484
B. Install water closet with a seat height of 17" - 19" above finish floor. The height of accessible water closet shall be a minimum of 17" and a maximum of 19" measured to the top of a maximum 2" high toilet seat. Exception: A 3" toilet seat shall be permitted only in alterations where the existing fixture is less than 15" high. CBC 1115B.4.1.4 Accessible Water Closet. / 28 CFR Part 36 App "A" Water Closets /
Findings - 16" to top of seat
ADA Inspection Plus, LLC
Fire Department Page 38 of 45485
C. All lavatories that are designated to be accessible shall be a minimum of 17" in horizontal depth and mounted with the rim or counter edge no higher than 34" above finish floor. CBC 11B-606.3 / 28 CFR Part 36 App "A" 4.19 Lavatories and Mirrors / ADAS 606.3
Findings - 37" to top of sink rim.
Note: No Action Required
ADA Inspection Plus, LLC
Fire Department Page 39 of 45486
D. Provide insulated wrapping around pipes under sink. Hot water and drainpipes accessible under lavatories shall be insulated or otherwise covered. There shall be no sharp or abrasive surfaces under lavatories. CBC 1115B.4.3.4 Accessible Lavatories / 28 CFR Part 36 App "A" 4.24.6 Exposed Pipes and Surfaces Findings - Exposed
Note: No Action Required
ADA Inspection Plus, LLC
Fire Department Page 40 of 45487
E. Provide required clear floor space. Where urinals are provided, at least one shall have a clear floor space 30" by 48" in front of the urinal to allow forward approach. CBC 11B-305 / 28 CFR Part 36 App "A" 4.18 Urinals / 2010 ADAS 305
In alcoves greater than 24", an additional 6" shall be required.
Findings - 40" (48" minimum required)
Note: No Action Required
ADA Inspection Plus, LLC
Fire Department Page 41 of 45488
F. Prove accessible urinal. Urinals shall be floor mounted, stall type or wall hung. Where one or more wall-hung urinals are provided, at least one with an elongated rim projecting a minimum of 13-1/2" from the wall and a maximum of 17" above finish floor shall be provided. CBC 11B-605.2 / 28 CFR Part 36 App "A" 4.18 Urinals / 2010 ADAS 605.2 Findings - 25" to rim
Note: No Action Required
G. 11B-605.4 Flush Controls. Flush controls shall be hand operated or automatic. Hand operated flush controls shall comply with 11B- 309 (Operable Parts) except that the flush control shall be mounted at a maximum height of 44 inches above the finish floor.
Findings - 46" to lever
Note: No Action Required
ADA Inspection Plus, LLC
Fire Department Page 42 of 45489
H. 11B-603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches maximum above the finish floor or ground. CBC11B-603.3 / 28 CFR Pt36 App A 4.19.6 / 2010 ADA Standards for Accessible Design 6.3.3 Findings - 53-1/2" / Greater than 40" to reflective surface.
No Action Required
ADA Inspection Plus, LLC
Fire Department Page 43 of 45490
I. Relocate (or provide same) restroom accessories to a height of 40" maximum to highest operable parts above finish floor. CBC 11B-603.5. / 28 CFR Part 36 App "A" 4.16.6 Dispensers Findings - (62" for Towel Dispenser) (61" Seat Covers)
Note: No Action Required.
J.
Estimated Cost: $3000
Note: No Action Required. Estimated cost are for information only if alterations or modifications are performed.
ADA Inspection Plus, LLC
Fire Department Page 44 of 45491
ADA Inspection Plus, LLC
CASp Evaluation Statement
This CASp Evaluation survey and inspection was performed per the request of City of Hermosa Beach for the property located at Fire Department, Hermosa Beach, CA 90254. This evaluation and inspection report is a comprehensive detailed report for accessibility for the property stated above in accordance with "2013 California Building Code" Chapter 11B (Title 24), the "Americans with Disabilities Act" 1991 guidelines (ADAAG) and the 2010 ADA Standards for Accessible Design as well as any other laws and regulation that apply. The areas of the property, dictated by City of Hermosa Beach , and only those areas dictated by City of Hermosa Beach , were inspected for code requirements and addressed in this report under the terms of a CASp Evaluation Agreement. The agreement was signed and agreed upon before the preparation of this report.
Fire Department Page 45 of 45492
Appendix B – ADA Evaluation Reports
A.8 Police Department (ADA Plus LLC)
493
Program Accessibility Evaluation Report
City of Hermosa Beach
Property Address:
Police Department
Hermosa Beach CA 90254
Inspection Date: 4/21/2015
PREPARED BY:
ADA Inspection Plus, LLC
Ron D Johnson CASp344
7349 Milliken Ave. #140-344
Rancho Cucamonga, CA 91730
(909) 732-5800
[email protected]
494
Date: 4/21/2015 Report ID: H.B.008
Property:
Police Department
Hermosa Beach CA 90254
Customer:
City of Hermosa Beach
ADA Inspection Plus, LLC
Police Department Page 2 of 68495
IMPORTANT INFORMATION. PLEASE READ THE FOLLOWING.
PROGRAM ACCESSIBILITY for Title II Facilities.
General. A public entity may not deny the benefits of its programs, activities, and services to individuals with disabilities because its facilities are inaccessible. A public entity's services, programs, or activities, when viewed in their entirety, must be readily accessible to and usable by individuals with disabilities. This standard, known as "program accessibility," applies to all existing facilities of a public entity. Public entities, however, are not necessarily required to make each of their existing facilities accessible.
ADA.gov - Public entity. A public entity covered by title II is defined as -- 1) Any State or local government;
2) Any department, agency, special purpose district, or other instrumentality of a State or local government; or 3) Certain commuter authorities as well as AMTRAK.
As defined, the term "public entity" does not include the Federal Government. Title II, therefore, does not apply to the Federal Government, which is covered by sections 501 and 504 of the Rehabilitation Act of 1973.
Title II is intended to apply to all programs, activities, and services provided or operated by State and local governments. Currently, section 504 of the Rehabilitation Act only applies to programs or activities receiving Federal financial assistance. Because many State and local government operations, such as courts, licensing, and legislative facilities and proceedings do not receive Federal funds, they are beyond the reach of section 504.
In some cases it is difficult to determine whether a particular entity that is providing a public service, such as a library, museum, or volunteer fire department, is in fact a public entity. Where an entity appears to have both public and private features, it is necessary to examine the relationship between the entity and the governmental unit to determine whether the entity is public or private. Factors to be considered in this determination include -- 1) Whether the entity is operated with public funds; 2) Whether the entity's employees are considered government employees;
3) Whether the entity receives significant assistance from the government by provision of property or equipment; and
4) Whether the entity is governed by an independent board selected by members of a private organization or a board elected by the voters or appointed by elected officials.
Relationship to title III. Public entities are not subject to title III of the ADA, which covers only private entities.
Conversely, private entities are not subject to title II. In many situations, however, public entities have a close relationship to private entities that are covered by title III, with the result that certain activities may be at least indirectly affected by both titles.
Applicable Codes and Regulations:
1991 Americans with Disabilities Act Accessibility Guidelines (ADAAG) 28 CFR Part 36 Appendix A 2010 ADA Standards for Accessible Design - Title II (State and Local Government Facilities) - ADA regulation taking affect for start date for construction is on or after March 15, 2012. Before this date, the 1991 Standards (without the elevator exemption), the UFAS, or 2010 Standards may be used for projects when used for projects when the start of construction commences on or after September 15, 2010.
Title 24 - California Building Code (2013) Chapter 11B
ADA Inspection Plus, LLC
Police Department Page 3 of 68496
California Building Code (2013) - Chapters 11A (Housing Accessibility) & CBC 2013 11B (Public Accommodations and Commercial Facilities), specifies the "Accessibility" requirements for buildings in California. In most cases the 11A & 11B are more stringent than the ADAAG. If the ADAAG has a more stringent requirement than that of the Title 24 CBC, then the ADAAG shall be the standard used. Title 24 CBC (2010), Section
1.9.1.5 - Special conditions for persons with disabilities requiring appeals action ratification. Whenever reference is made in these regulations to this section, the findings and determinations required to be rendered by the local enforcement agency shall be subject to ratification through an appeals process. This simply means that if an element in question cannot be modified per the requirements of the ADA or Title 24, then an appeals board, through the local agency, will make the determination on how to resolve the issue. This determination will then be filed with the local agency.
Age Of building:
Pre ADA Regulations
ADA Inspection Plus, LLC
Police Department Page 4 of 68497
Table of Contents
Cover Page.................................................................1 Intro Page ...................................................................2 Table of Contents........................................................5 1 Inspection Scope .....................................................6 2 Entrance Doors........................................................7 3 Miscellaneous Doors..............................................10 4 Service Counters ...................................................12 5 Dining and Work Surfaces .....................................14 6(A) Men's Restroom Door .......................................17 6(B) Women's Restroom Doors ................................23 7(A) Men's Restroom ................................................29 7(B) Women's Restroom...........................................38 8 Restrooms..............................................................47 9 Accessible Roll-in Showers & Tubs .......................52 10 Drinking Fountains...............................................62 11 Detention Facilities and Correctional Facilities ....65 Agreement ................................................................68 ADA Inspection Plus, LLC
Police Department Page 5 of 68498
1. Inspection Scope
C N/C Yes No I N/I A/R N/A A
A. Inspection Scope and Areas. •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A.
Doors, Cells and General Housing, Visiting Areas, Cubicles & Counters, Restrooms, General Circulation.
Exterior Elements, See Report HB.010 ADA Evaluation - Exterior Elements City Hall, Police & Fire ADA Inspection Plus, LLC
Police Department Page 6 of 68499
2. Entrance Doors
C N/C Yes No I N/I A/R N/A A
A.
Door with a closure closes no faster that 5 seconds from an opened position 90deg to 12deg from the latch when closing.
•
B.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
C. Smooth surface 10" at the bottom of door on the push side. • D.
An EXIT sign with Contracted Grade II Braille shall be placed on the strike side of the interior spaces leading to an accessible Exit.
•
E. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Adjust or provide door closure so that from an opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door.CBC 11B-404.2.8.1 / 28 CFR Part 36 App. A - 4.13.10 / 2010 ADAS-404.2.8.1 / Spring hinges are 70deg to closed position in 1.5 seconds minimum) Findings - 3 Seconds 90-12
ADA Inspection Plus, LLC
Police Department Page 7 of 68500
B. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware which ever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
Findings - 7lbs (Minor Violation)
C. Provide a 10" smooth panel on the push side of door or gate. Cap all voids at top of smooth panel if void is present. CBC 11B-404.2.10 / ADA 2010 Standards: 404.2.10 Door and Gate Surfaces (Exception 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor shall not be required to provide smooth surfaces complying with 404.2.10 provided that if added kick plates are installed, cavities created by the kick plates are capped.)
Findings - Door Stop in 10" smooth area
ADA Inspection Plus, LLC
Police Department Page 8 of 68501
D. Provide tactile EXIT sign at exit doors in accordance with CBC 11B-703 Signs / ADA 2010 Standards: 216.4 Means of Egress / No provisions in 28 CFR Pt 36 App A.
Findings - Not provided
E.
Estimated Cost $100
ADA Inspection Plus, LLC
Police Department Page 9 of 68502
3. Miscellaneous Doors
C N/C Yes No I N/I A/R N/A A
A. Threshold - 1/4" or 1/2" beveled at 1:2 between 1/4" and 1/2" • B. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide or modify door threshold or raise maneuvering space so that the floor or landing shall not be more than 1/2" lower than the top of the threshold of the doorway. Changes in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2. CBC 11B-404.2.5 Thresholds / 28 CFR Part 36 App A: 4.13.8 Thresholds at doorways /ADA 2010 Standards: 404.2.5 Thresholds
ADA Inspection Plus, LLC
Police Department Page 10 of 68503
A.
Entry door at detainee unloading area. Findings - 6" step into the building at the threshold.
A. Pass-through door from detainee unloading area. Findings - 5/8" vertical change in elevation to the top of the threshold. (1/4" vertical and 1/4" beveled max required) B.
Estimated Cost: $2500 (to building a landing and ramp to landing at the detainee loading area.) ADA Inspection Plus, LLC
Police Department Page 11 of 68504
4. Service Counters
C N/C Yes No I N/I A/R N/A A
A. Counter top shall be 36" minimum width and 28" to 34" high maximum. • B. Clear Floor or Ground Space of Wheelchairs •
C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. Provide or modify sales or service counter to 28" minimum to 34" maximum height and 36" minimum long. Where counters have cash registers and are provided for sales or distribution of goods and services to the public, at least one of each type shall have a portion of the counter which is at least 36" in length with a maximum height of 34" above finish floor and located on an accessible route. Exception: In existing buildings where it is determined that providing an accessible counter would create an unreasonable hardship, equivalent facilitation may consist of one of the following: 1. An auxiliary counter, in close proximity, meeting these requirements, may be provided. 2. Provision of a folding shelf attached to the main counter on which an individual with disabilities can write. CBC 11B-904.4 / 36" max high required in ADA 28 CFR Part 36 App A 7.2 Sales and Services Counters, Teller Windows, Information Counters / 2010 ADA Standards 904.4 (CBC more restrictive) A. Information Service Counter shall be accessible. Findings - 36" to top of counter (Not an ADA Violation, Violation with CA Building code requirements.)
The pass through window is greater than 36" which is a violation.
Provide accessible counter.
ADA Inspection Plus, LLC
Police Department Page 12 of 68505
B. Provide a clear floor space of 30"x48" for a parallel approach at the sales or service counter. Knee clearance is not required. CBC1118B.4 Clear floor and ground space for wheelchairs / 28 CFR Part 36 App A 4.2.4 Clear Floor and Ground Space for Wheelchairs / 2010 ADA Standards 904.4.1 Parallel Approach Findings - No Clear floor space provided.
C.
Estimated Cost: $2500
ADA Inspection Plus, LLC
Police Department Page 13 of 68506
5. Dining and Work Surfaces
C N/C Yes No I N/I A/R N/A A
A. Detention Facilities and Correctional Facilities shall comply with 11B-232.5.1 • B.
Table and counter height for persons in a wheelchair 28" minimum to 34"maximum with proper knee clearance of 27" and a minimum width of 30" clear.
•
C. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable Comments:
A. 11B-232.5 Visiting Areas. Visiting areas shall comply with 11B-232.5. (ADAS 2010, 232) 11B-232.5.1 Cubicles and Counters. At least 5 percent, but no less than one, of cubicles shall comply with 11B-902 (Dining Surfaces and Work Surfaces) on both the visitor and detainee sides. Where counters are provided, at least one shall comply with 11B-904.4.2 (Forward Approach) on both the visitor and detainee or inmate sides.
EXCEPTION: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with 11B-232 (Detention Facilities and Correctional Facilities) shall not be required to comply with 11B-902 (Dining Surfaces and Work Surfaces) or 11B-904.4.2 (Forward Approach). 11B-232.5.2 Partitions. Where solid partitions or security glazing separate visitors from detainees or inmates at least one of each type of cubicle or counter partition shall comply with 11B-904.6 (Security Glazing).
ADA Inspection Plus, LLC
Police Department Page 14 of 68507
A. This area is used for the public to discuss matters with an officer. The public side shall meet ADA code requirements.
The officer side of the security glass is considered an employee work station and is required to be accessible if altered or modified. The violation is limited to the full depth of the knee clearance of 19" minimum.
See Item
B. Provide a table with a knee space of at least 27" high, 30" wide and 19" deep (CBC11B-306). Table or counter height shall be 28" min and 34" max above finish floor. (CBC 11B-902.3) / 28 CFR Part 36 App A 4.32.2 Knee Clearance / 2010 ADA Standards 306 & 902
ADA Inspection Plus, LLC
Police Department Page 15 of 68508
B. Findings - 15" depth of counter Public and officer side of counters.
C.
Estimated Cost: $4000
ADA Inspection Plus, LLC
Police Department Page 16 of 68509
6(A) . Men's Restroom Door
C N/C Yes No I N/I A/R N/A A
A.1.
Men's sanitary facility - proper signs (1/4" thick, 12" equilateral triangle / light on dark or dark on light) Permanent Room Identification Sign (Braille) •
B.1. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • C.1. 5 seconds from 90deg to 12deg from latch. •
D.1.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
E.1.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
F.1. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Police Department Page 17 of 68510
Comments:
A.1. 11B-216.8 Toilet Rooms and Bathing Rooms. Doorways leading to toilet rooms and bathing rooms complying with 11B- 603 (Toilet and Bathing Rooms) shall be identified by a geometric symbol complying with 11B- 703.7.2.6 (Toilet and Bathing Facilities Geometric Symbols). / ADA 2010 Standards: 216 Signs.
ADA Inspection Plus, LLC
Police Department Page 18 of 68511
A.1.
Tactile Sign Not Provided
B.1. Provide 32" clear width from face of door at 90deg to opposite stop. Door 3' wide by 6'-8" shall be provided.
CBC 11B-404 / 28 CFR Part 36 App. A - 4.13 Doors / ADA 2010 Standards: 404 Doors, Doorways, and Gates Findings - 28-1/2" clear width
ADA Inspection Plus, LLC
Police Department Page 19 of 68512
C.1. Adjust or provide door closure so that from an opening position of 90deg, the door will take at least 5 seconds to move to a point 12deg from the latch, measured from the leading edge of the door.CBC 11B-404.2.8.1 / 28 CFR Part 36 App. A - 4.13.10 / 2010 ADAS-404.2.8.1 / Spring hinges are 70deg to closed position in 1.5 seconds minimum)
Findings - 2 Seconds 90-12
D.1. Modify door pull/push force to maximum of 5lbs of pressure 30" from the hinge or the door hardware which ever is furthest from the hinge. CBC 11B-404.2.9 / 28 CFR Part 36 App. A - 4.13.11 / ADA 2010 Standards: 404.2.9 Door and Gate Opening Force. ADA Interior Doors Only
Findings - 8lbs
ADA Inspection Plus, LLC
Police Department Page 20 of 68513
E.1. 11B-404.2.4.3 Recessed Doors and Gates. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side of an interior doorway, or within 24 inches of the latch side of an exterior doorway, projects more than 8 inches beyond the face of the door, measured perpendicular to the face of the door or gate./ 28 CFR Part 36 App. A - 4.13 / ADA 2010 Standards: 404.2.4 Maneuvering Clearances ADA Inspection Plus, LLC
Police Department Page 21 of 68514
E.1.
Findings - 2" strike side clearance on push side of door. (12" required when both latch and closure are provided)
This may be "Technically Infeasible" to provide strict and full compliance for doors. This may need to be verified by an engineer to determine the feasibility and if structural wall would need to be altered to meet accessibility requirements.
F.1.
Estimated Cost: $3000
ADA Inspection Plus, LLC
Police Department Page 22 of 68515
6(B) . Women's Restroom Doors
C N/C Yes No I N/I A/R N/A A
A.2.
Women's sanitary facility - proper signs (1/4" thick, 12" circle / light on dark or dark on light)
•
B.2. Accessible door 3'wide x 6'8" high with at least 32 inches clear width. • C.2. 5 seconds from 90deg to 12deg from latch. •
D.2.
Pull/push force 5lbs or less tested from 30" from hinge or door hardware whichever is furthest.
•
E.2.
Strike side clearance on the level area at the swing side of the door. 24" exterior 18" interior.
•
F.2. Estimated Cost for Remediation This Section •
C N/C Yes No I N/I A/R N/A A
C= Compliant, N/C= Non Compliant, Yes= Yes, No= No, I= Inspected, N/I= Not Inspected, A/R= Action Required, N/A= Not Applicable, A= Applicable ADA Inspection Plus, LLC
Police Department Page 23 of 68516
Comments: