City of Monterey ADA Transition Plan Update Executive Summary March 11, 2013 S a l l y S w a n s o n A r c h I t e c t s, I n c.
Official(s) Responsible
The ADA requires that an official be identified as responsible for the implementation of the Entity’s plan.
It is the US DOJ's view that compliance with 28 CFR 35.150(a), like compliance with the corresponding provisions of the section 504 regulations for public programs, would in most cases not result in undue financial and administrative burdens on a typical City. In determining undue financial and administrative burdens, all City resources available for use in the funding and operation of City services, programs and activities would need to be considered.
The burden of proving that compliance with paragraph (a) of 28 CFR 35.150 would either fundamentally alter the nature of a service, program, or activity OR would result in undue financial and administrative burdens rests with the City. The decision that compliance would result in such alteration and/or burden must be made by the head of the public entity or his or her designee and must be accompanied by a written statement of the reasons for reaching that conclusion.
While the US DOJ has acknowledged the difficulty/complexity of not only making such a determination, but also identifying the official responsible to make this decision/determination, the department's intention is clear in that the determination must be made by a high level official, no lower than a Department head, having budgetary authority and responsibility for making spending decisions.
The Official Responsible for the implementation should be able to seek/acquire funding for ADA barrier removal work over the City’s Transition Planning period. In most cities, it is the City Manager who can effectively control the City’s budget line item – “ADA Transition Planning budget”. As such, The City of Monterey will designate __________ as the Official Responsible for the implementation of its ADA Transition Plan. In the City of Monterey, the barriers identified in Parks, Buildings and the Rights-of-Way will all fall in the purview of the City Manager and/or his respective Directors – i.e. Community Development, Parks & Recreation, Public Works/Engineering, etc.
Typically, the responsibility of making any particular City program, service or activity accessible to all persons, regardless of ability, rests with the official who controls the operating funds for that particular program, service or activity. To this end, the task of seeking/getting approval for funds from the governing body to make the said program accessible lies with the official responsible for the program.
Indication of the official(s) responsible for implementation of the plan fulfills the final requirement of a Transition Plan.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3671, Packet Page 3876
City of Monterey ADA Transition Plan Update Executive Summary March 11, 2013 S a l l y S w a n s o n A r c h I t e c t s, I n c.
Public Input
A public meeting is to be held on Friday, March 22, 2013 to invite the public to comment on the City’s Draft ADA Transition Plan Update. A meeting notice was posted on the City’s website and published in two local newspapers two weeks before the meeting. Invitations to the meeting were sent to several stakeholder groups for persons with disabilities.
Transition Plan Implementation
The document should be maintained and updated for the duration of the Transition Planning period and a copy of the transition plan shall be made available for public inspection.
The final product is a working document to be modified as barriers are removed or alterations are made. The Official(s) responsible and project managers overseeing the barrier-removal projects will document all such ADA improvements/upgrades. Also as part of this process, technical infeasibility, if any, to meet necessary accessibility compliance will be documented and filed for the City’s records by the Engineer-of-Record on the said project. It is also recommended to provide accessibility site audits (inspections) of on-going projects as part of the project close-out/certification. This documentation and verification of barrier-mitigation will be integrated into the City’s ADA Transition Plan on a regular basis to ensure that barriers are “checked-off” and the Plan is current with a record of barrier-mitigation work. Annual reports of barrier-mitigation work may also be provided to City Council.
This is a living document and is open to modification throughout the transition period. Identified in the appendix of the Transition Plan, are proposed facilities barrier-mitigation sorted and assigned by the City programs/plans. Also identified in the appendix of the Transition Plan, is a list of issues that will be included as part of the City’s maintenance programs.
The City has formed an ADA Compliance Team. The Team is tasked with analyzing the City’s ADA Compliance efforts and implement, where necessary, changes to the City’s policies, procedures and infrastructure to ensure that they adhere to the guidelines set forth in the ADA Regulations and that the City’s programs, services or activities are accessible to people with disabilities. This team will meet on a biannual basis.
The City will continue to plan for an annual “ADA Transition Planning budget”. This budget will be used to plan mitigation of those barriers identified in the Plan that are not part of any CIP project or Bond program. This budget will be in addition to and separate from funds required for any ADA improvements and upgrades triggered on account of CIP projects and Bond Programs. The scope of work and budget for all such CIP and bond projects must incorporate the improvements triggered by applicable Federal, State and local accessibility regulations and codes.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3672, Packet Page 3877
City of Monterey ADA Transition Plan Update Executive Summary March 11, 2013 S a l l y S w a n s o n A r c h I t e c t s, I n c.
FUNDING TYPES FUNDING SOURCES
CIP - General Fund General Fund
Parking Fund
Gas Tax
Marina Fund
Wharves 1 & 2 Fund
POM - Presidio of Monterey
NIP - Neighbor Improvement Plan Fully Funded
Partial/Other Funded
Cut-Off Projects
Maintenance of Accessible Features
Finally, the Maintenance of accessible features is mandated by State and Federal Regulations and is an integral part of the City’s plan to transition into a more accessible destination. Both, Chapter 28 Code of Federal Regulation, Part 35, Section 35.133 as well as the California Building Code section 1101B.3 – Maintenance of accessible features, state:
1. A public accommodation shall maintain in operable working condition those features of facilities and equipment that are required to be accessible to and usable by persons with disabilities.
2. This section does not prohibit isolated or temporary interruptions in service or access due to maintenance or repairs.
Both these sections provide that a public entity shall maintain in operable working condition those features of facilities and equipment that are required to be accessible to and usable by persons with disabilities. They require that, to the maximum extent feasible, facilities must be accessible to, and usable by, individuals with disabilities. These sections recognize that it is not sufficient to provide features such as accessible routes, ramps, or elevators, if those features are not maintained in a manner that enables individuals with disabilities to use them. Inoperable elevators, are neither "accessible to" nor "usable by" individuals with disabilities.
It is, of course, impossible to guarantee that mechanical devices will never fail to operate. As such, the 2nd paragraph provides that this section does not prohibit isolated or temporary interruptions in service or access due to maintenance or repairs. This paragraph is intended to clarify that temporary obstructions or isolated instances of mechanical failure would not be considered violations of the ADA or this part. However, allowing obstructions or "out of service" equipment to persist beyond a reasonable period of time would violate this part, as would repeated mechanical failures due to improper or inadequate maintenance. Failure of the public entity to arrange prompt repair of inoperable elevators or other equipment intended to provide access would also violate this part.
A City-wide formal policy specifically addressing the legal requirements (28CFR Part 35.133 & CBC1101B.3) of maintaining accessible features would be of long-term benefit to the City.
When, over time, an accessible feature fails, institutionalizing organizational commitments towards protocols and maintenance ensures an appropriate action is taken.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3673, Packet Page 3878 SSA Project # 11037
City of Monterey - ADA Transition Plan
March 2013
Section: II Self-Evaluation
A. Report of Findings, Recommendations and Model
Policies
B. Self-Evaluation Questionnaire Tool
C. Department Responses Matrix
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3674, Packet Page 3879 City of Monterey Self Evaluation report
Instructions: Use this chart to track the status of findings/recommendations identified in the City's Self Evaluation.
Status key: Completed
Minor policy revision that need attention but will not delay implementation Progress key:
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Sally Swanson Architect is under contract to provide services designed to comply with this mandate 28CFR Part 35.150
$ -
Provide guidance on furniture placement and make communication devices, such as telephones, accessible to staff. 28CFR Part 35.150
$ -
The program needs to be made accessible to and useable by qualified persons with disabilities. This can be achieved either by relocating the program to an accessible location or exploring 28CFR Part 35.150
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Major policy revision/implementation that need attention and will (or most likely will) be delayed I. Examine Programs for Physical Barriers
$ -
Months
City of Monterey Self Evaluation Plan - Status Chart
Task progress and deadline
SSA Inc. Page 1 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3675, Packet Page 3880 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
We concur and recommend that any policy developed be implemented City wide. 28CFR Part 35.130 & 35.149 $ -
Develop, disseminate and implement Policies and Practices to ensure policy modification requests and alterations are handled appropriately on a Citywide 28CFR Part 35.130 & 35.149
$ -
Develop Policies and Procedures to ensure persons with disabilities are notified of the City's willingness to provide 28CFR Part 35.130 & 35.149 $ -
ADA Title II requires that all programs, services and activities be readibly accessible to and useable by qualified 28CFR Part 35.130 & 35.149 $ -
If this barrier (Colton Hall & PBL Building) is not resolved within the transition plan, Program Access Solutions must be entertained to determine what solutions might exist for creating an acceptable 28CFR Part 35.130 & 35.149
$ -
Offer guidance and training of provided services available in an integrated setting, including communications, awareness, policy modification and accessible meetings. 28CFR Part 35.130 & 35.149
$ -
Standardize language in 3rd party contractor agreements to ensure conformance to the City's disability policies and procedures. 28CFR Part 35.130 & 35.149
$ -
Develop a consistent approach to address matters related to alledged discrimination within 3rd party 28CFR Part 35.130 & 35.149 $ -
Develop a written policy to ensure the provision of auxilary aides and services remains free of charge. 28CFR Part 35.130 & 35.149
Develop and distribute an appropriate ADA Non-Discrimination Notice policy. 28CFR Part 35.130 & 35.149
Draft a Service Animal Policy with guidance for staff. This policy should be sensitive to the 2010 Regulations, as well as potential inconsistencies which may emerge in State Law. 28CFR Part 35.130 & 35.149
II. Review Practices that Limit Participation
SSA Inc. Page 2 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3676, Packet Page 3881 City of Monterey Self Evaluation report
Such policy and guidance should be developed and disseminated. 28CFR Part 35.130 & 35.149
Develop a Guidance Document and train maintenance staff to ensure compliance 28CFR Part 35.130 & 35.149
Update the policy to ensure compliance with the 2010 ADA Regulations. 28CFR Part 35.130 & 35.149
Evaluate Emergency Dispatch staff to determine their proficiency in use of the TTY systems. Provide training if needed. 28CFR Part 35.130 & 35.149
Develop guidance for impacted officers. 28CFR Part
35.130 & 35.149
Develop and disseminate information and guidance to officers regarding communication with persons with cognitive disabilities, if it has not been done so to date. 28CFR Part 35.130 & 35.149
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
$ -
SSA Inc. Page 3 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3677, Packet Page 3882 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Cover this topic in Disability Awareness Training, as guidance would be beneficial to City staff. 28CFR Part 35.160 & 35.161
$ -
Disability Awareness Training would be beneficial.
28CFR Part 35.160 & 35.161 $ -
Develop a policy mandating the testing of Web based forms prior to use on any City website. 28CFR Part 35.160 & 35.161 $ -
Should the City ever use touch screen systems, it is strongly recommended that 28CFR Part 35.160 & $ -
Disseminate guidance in this area to all impacted City staff to ensure continuity. 28CFR Part 35.160 & 35.161 $ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
III. Review Policies for Effective Communication
Months
$ -
SSA Inc. Page 4 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3678, Packet Page 3883 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Put in place guidance addressing the City's obligation to provide auxiliary aides and services (accommodations) to persons with disabilities as needed.Identify resources within the 28CFR Part 35.160(b)
$ -
Develop and disseminate guidance regarding video purchasing. It should be noted that this area may be subject to change as the US Dept of Justice is 28CFR Part 35.160(b)
$ -
Utilize the EEOC guidance relative to identifying employees in need of assistance during an emergency. 28CFR Part 35.160(b)
$ -
Develop guidance to assist impacted staff in administering the Interactive Process within the context of Emergency Planning. 28CFR Part 35.160(b)
$ -
Develop and disseminate specific guidance to ensure continuity in the Interactive Process, relative to Accommodations addressing Emergency 28CFR Part 35.160(b)
$ -
Develop, exercise and debrief emergency management plans for all impacted properties. The ADA Coordinator or his designee should participate in this process to ensure the needs of persons 28CFR Part 35.160(b)
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
IV. Review Policies to Secure Services/Equipment
$ -
Months
SSA Inc. Page 5 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3679, Packet Page 3884 City of Monterey Self Evaluation report
SSA Inc. Page 6 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3680, Packet Page 3885 City of Monterey Self Evaluation report
Recommendations for City Facilities
Code Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
If in planning it is determined the use of Emergency Evacuation Chairs are desireable for a given site, stairwells should be examined for accessibility of the chairs prior to equipment purchase. 28CFR Part 35.162 & 35.164
$ -
Emergency management plans should be developed, exercised and debriefed for all impacted properties. The ADA Coordinator or his designee should participate in this process to ensure the needs of persons with disabilities are factored into planning. 28CFR Part 35.162 & 35.164
$ -
If the City elects to use a buddy system to support emergency management during planning, careful role definition and redundancies should be built into the system. 28CFR Part 35.162 & 35.164
$ -
Communication from the command center to the area of safe refuge should be considered in emergency planning particularly as it relates to persons who 28CFR Part 35.162 & 35.164
$ -
Put in place a system to account for all occupants of evacuated sites. 28CFR Part 35.162 & 35.164 $ -
Develop guidance to address issues relative to examining the worksite of a person with a visual impairment during a bomb threat. 28CFR Part 35.162 & 35.164
$ -
Should facilities be used for mass care sheltering, consideration should be exercised concerning sleeping areas, toilet and shower facilities, eating 28CFR Part 35.162 & 35.164
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
$ -
Months
V. Review Emergency Evacuation Procedures
SSA Inc. Page 7 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3681, Packet Page 3886 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Develop and disseminate language and etiquette guidance to all City Employees who have public contact or create publications and documents on behalf of the City. These parties should also have disability awareness training. 28CFR Part 35.160
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
$ -
VI. Review Written and Audio-Visual Materials
SSA Inc. Page 8 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3682, Packet Page 3887 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
The City of Monterey is involved in a survey process leading towards a transition plan to ensure accessiblity to City's programs, activities and services. Should problems in this area be identified in that process they should be mitigated within the four steps of the Transition Plan. 28CFR Part 35.150(a)(2) & (b)(2) $ -
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
VII. Review Access within Historic Facilities
$ -
SSA Inc. Page 9 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3683, Packet Page 3888 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Put into place a procedure to evaluate ADA related policy modification requests and to determine whether said requests 28CFR Part 35.150(a)(3) & 35.164 $ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
VIII. Review Hardship Approval Policy
$ -
SSA Inc. Page 10 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3684, Packet Page 3889 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Formalize a system-wide approach including access surveys, provisions of auxiliary aides and services and disability etiquette. Incorporate the system into City 28CFR Part 35.130
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
$ -
IX. Review Policies for Access to Meetings/Events
Months
SSA Inc. Page 11 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3685, Packet Page 3890 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
It is recommended the City study this process to develop a manner in which applicants with disabilities have equitable access to the application process. 28CFR Part 35.140 & FEHA
$ -
The City should double its efforts in an attempt to ensure that all candidates are aware in advance of the general activities they are expected to engage in during selection. 28CFR Part 35.140 & FEHA
$ -
The City should develop and disseminate Policy/Guidance on this topic. 28CFR Part 35.140 & FEHA $ -
Upon creation of a policy it should be disseminated to candidates and staff. 28CFR Part 35.140 & FEHA $ -
Reasonable Accommodation procedures should be developed and disseminated to include forms to document the City's efforts. 28CFR Part 35.140 & FEHA
$ -
The criteria should be clearly spelled out in the Guidance recommended above. 28CFR Part 35.140 & FEHA $ -
X. Review Employment Practices for Supervisors/Managers SSA Inc. Page 12 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3686, Packet Page 3891 City of Monterey Self Evaluation report
A Policy/Guidance should be developed to address this coordination issue. 28CFR Part 35.140 & FEHA $ -
Emergency Planning must be conducted in a manner that covers all City sites. 28CFR Part 35.140 & FEHA $ -
The City should, on a voluntary basis, ask all employees at the time of hire if they need assistance during an emergency. They should also ask all staff annually on a voluntary basis if they need assistance during an emergency, and finally, if management observes a change in an employees condition, which might impact them during an emergency, they should ask if the employee would need assistance 28CFR Part 35.140 & FEHA
$ -
As recommended above the City should develop and disseminate an ADA Grievance Process. 28CFR Part 35.140 & FEHA $ -
It is recommended that at a minimum duty statements be revised prior to the selection process, and ideally, they should be reviewed and updates considered at the time of performance review, in addition to the review at accommodation. 28CFR Part 35.140 & FEHA
$ -
The specific policy should be reviewed, updated if needed and broadly disseminated. 28CFR Part 35.140 & FEHA
Disseminate to impacted staff as appropriate resources available to obtain needed information. This may also be accomplished in part through the 28CFR Part 35.140 & FEHA
This information should be contained in the Reasonable Accommodation Guidance. 28CFR Part 35.140 & FEHA
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
$ -
SSA Inc. Page 13 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3687, Packet Page 3892 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15
Status Comments
A systemic approach to lease acquistion and renewal should be developed and disseminated to impacted parties. The objective within would be to ensure that the City did not enter into or renew a lease agreement in which access barriers would become a liability for the City. 28CFR Part 35.150
$ -
Develop guidance to ensure that impacted parties have access to basic information concerning the appropriate placement of furniture and equipment to avoid access barriers. Train impacted staff to ensure ongoing compliance. 28CFR Part 35.105
$ -
We recommend that guidance and training be offered to impacted staff. 28CFR Part 35.105
It appears the only pending complaint is being addressed 28CFR Part 35.133 & CBC1101B.3 $ -
A procedure to ensure that maintenance of accessible features becomes a priority of all impacted City staff should be put in place. Training of maintenance staff would be an important factor in implementing this new procedure. 28CFR Part 35.133 & CBC1101B.3
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
XI. Review Building and Construction Policies
$ -
SSA Inc. Page 14 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3688, Packet Page 3893 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15
Status Comments
Due to the observations made within the Self Evaluaion Process and the responses contained within Section 12, we are recommending the following: the City should have a traiining program which would include, but not be limited to : 1) Disability etiquette and awareness for staff having public contact; 2) communication and meeting/event production for staff involved in the production of meetings and events; 3) emergency management for persons with disabilities for staff involved in the emergency management plan; 4) maintaining accessible features for all maintenance and custodial staff; 5) accessibility issues within lease, and lease renewal acquistion. These trainings should be supported by a series of guidance documents which should be available on a shared drive and accessible to staff as needed. The topics of the Guidance Documents should vary broadly. 28CFR Part 35.105
$ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Months
XII. Determine Training Needs for Employees/Subordinates $ -
SSA Inc. Page 15 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3689, Packet Page 3894 City of Monterey Self Evaluation report
Recommendation Code
Citation
Official Responsible/Dept/Div
Actual
Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15 Status Comments
Develop a policy to bring the City into compliance with this Federal mandate. 28CFR Part 35.131 $ -
Total Expense:
Total Time:
Dependencies on:
Dependencies for:
General comments:
Administrative RequirementsRecommendation Code
Citation
Official Responsible/Dept/Div
Actual Expense (if applic.)
Q3 13-14
Q4 13-14
Q1 14-15
Q2 14-15
Q3 14-15
Q4 14-15
Status Comments
Establish and broadly disseminate an ADA/Disability Civil Rights Grievance system, using the US Department of Justice Grievance template as a basis. 28 CFR 35.105-35.107; 35.150(c) and (d).
Develop a working support group comprised from key City Departments and a Citizen's Disability Advisory Committee representing a variety of disabling conditions to provide the ADA Coordinator with support and insight on ADA issues. 28 CFR 35.105-35.107; 35.150(c) and (d).
If program access solutions are used, the City must specify the manner in which programs will be offered in an alternative manner to ensure they are accessible to persons with disabilities. This system should be specific enough to identify staff involved and the solutions available. If training is necessary to implement program access solutions, it should be provided to impacted staff. 28 CFR 35.105-35.107; 35.150(c) and (d).
The development of an ADA Notice of Compliance should be created and broadly disseminated to ensure the City is in conformance with Federal ADA Mandates. 28 CFR 35.105-35.107; 35.150(c) and (d).
Months
XIII. Review Nondiscriminatory Practices
$ -
SSA Inc. Page 16 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3690, Packet Page 3895 City of Monterey Self Evaluation report
Develop and disseminate an Anti Surcharge Policy to ensure appropriate compliance with Federal Compliance. This policy should also be incorporated into the aforementioned ADA Notice. 28 CFR 35.105-35.107; 35.150(c) and (d).
Involve the ADA Coordinator in Emergency Planning.
28 CFR 35.105-35.107; 35.150(c) and (d).
Total Expense: #REF!
Total Time: Months
Dependencies on:
Dependencies for:
General comments:
SSA Inc. Page 17 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3691, Packet Page 3896
TEMPLATE
CITY OF MONTEREY
Self Evaluation Questionnaire
All rights reserved R. Michael Paravagna, 2012 Sally Swanson Architects Inc. 220 Sansome Street • Suite 1100
San Francisco • CA 94104
Phone 415.445.3045 • Fax 415.445.3055
SURVEY RESPONDENT INFORMATION City Department and/or Division: Name & Designation: Email Address & Telephone #: Survey Completion Date:
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3692, Packet Page 3897
TEMPLATE
City of Monterey Self Evaluation
Page ii
Table of Contents
Introduction iii
QUESTIONNAIRE SECTIONS
Administrative Requirements 1
I. Examine Programs for Physical Barriers 5
II. Review Practices that Limit Participation 6
III. Review Policies for Effective Communication 8
IV. Review Policies to Secure Services/Equipment 9
V. Review Emergency Evacuation Procedures 10
VI. Review Written and Audio-Visual Materials 13
VII. Review Access within Historic Facilities 14
VIII. Review Hardship Approval Policy 14
IX. Review Policies for Access to Meetings/Events 15
X. Review Employment Practices for Supervisors/Managers 15 XI. Review Building and Construction Policies 21
XII. Determine Training Needs for Employees/Subordinates 22 XIII. Review Non-discriminatory Practices 22
Summary – key citations 24
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3693, Packet Page 3898
TEMPLATE
City of Monterey Self Evaluation
Page iii
INTRODUCTION
Instructions for completion of the Self Evaluation questionnaire The Americans with Disabilities Act (ADA) requires that all programs offered by public entities be accessible to and useable by persons with disabilities when the programs are viewed in their entirety. Key ADA citations are referenced at the end of this questionnaire for your information. The purpose of this checklist is to provide the teams or individuals, reviewing their department’s policies, practices and procedures, a structure for evaluating the programs, services and activities therein as measured against the aforementioned requirement. Programs vary from department to department and their application frequently varies within any given department/division. For this reason no program survey checklist is perfect. One of the valuable contributions you can make as a reviewer is to add items to the checklist, which you believe are pertinent to your programs’ functioning and the requirements of the ADA.
We ask that you evaluate policies which your program has responsibility for. For example, HR Staff and department managers would be primarily responsible for the checklist items found in Section 10 (Employment). However, it is recommended that all supervisors review this section and flag questions or make comments as necessary. You may also find that some sections are not pertinent to your City department as a whole. This would be the case if you do not conduct business from any historic sites and, therefore would not be responsible for completing Section 7.
As you find areas of deficiencies, please note them and include your suggestions as to how they may be remediated. Suggestions are most helpful when they note the deficiency, the proposed method of mitigation, the persons responsible and a suggested timeline as appropriate. Additionally, you may find areas where practices are inconsistent with policy. Should that occur, please make note of that, as this may be a staff training issue.
If when going through the survey tool you find yourself unable to respond to certain items that you believe are pertinent, please make note of those items so that appropriate consultation and guidance can be provided. If you believe the attachment of a given policy to the survey form will assist in communicating the structure of the policy, please submit the policy with this survey tool. Please advise your teams responding to the questionnaire on behalf of their respective departments/divisions to submit the completed forms via email by _____, 2012.
Finally, we thank you for the time and energy you are investing in evaluating your program function, in order that it can meet the legal mandates of the Americans with Disabilities Act and State Law as appropriate. The end result will also lead us to discrimination free program services delivered in the most integrated setting possible. Should you have any questions or concerns in responding to this
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3694, Packet Page 3899
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 4 questionnaire, please do not hesitate to contact us via email at [email protected]
ADA Coordinator and persons responsible for
facility acquisition or maintenance should
respond to Section I.
All Surveyors should respond to Section II
through Section IX & Section XII.
All Supervisors, Managers and HR Staff should
respond to Section X.
Section XI should be addressed by persons
having responsibilities for Building Construction
or acquisition;
Section XII should be responded to by all parties.
Section XIII should be responded to by the ADA
Coordinator.
If in responding to the questionnaire, you
reference any policy or procedure, please attach
the policy or procedure to this document.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3695, Packet Page 3900
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 1
ADMINISTRATIVE REQUIREMENTS
(for the ADA Coordinator)
1. Does your City have 50 or more employees?
2. Are you aware of a grievance procedure that been developed to resolve ADA related issues within your department/division (or City-wide)?
3. How is the grievance procedure made available to stakeholders relating to your department/division?
4. Does the grievance procedure contain time lines, which facilitate a timely resolution of the complaint?
5. Is the complainant informed of the disposition of the grievance? Please state how.
6. If the complainant needs assistance because of his/her disability in filing the grievance, is such assistance made available? If yes, how is information regarding this support service made available to the public?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3696, Packet Page 3901
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 2
7. Is there a separation of duties between the person who handles grievances and the persons who provide reasonable accommodation, policy modification or auxiliary aides and services?
8. Does the designated Coordinator of the ADA/504 efforts have ready access to Senior Management? Is information regarding this person’s identity readily available to staff and constituents? If yes, how is this information disseminated?
9. What assistance do you believe the ADA Coordinator would benefit from in executing ADA implementation responsibilities?
10. A review of physical access concerning all sites from which your department/division provides programs, services and activities must be conducted. Has such a review occurred?
11. Did the review contain the following elements:
a. A list of all physical barriers
b. The method to be used to mitigate the barrier
c. A time line for barrier mitigation
d. The person responsible for administering the transition plan
12. Who is responsible for monitoring the work done under the Transition Plan?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3697, Packet Page 3902
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 3
13. When was the Transition Plan last updated?
14. Has the scope of the Transition Plan been increased to incorporate new elements covered within the 2010 Standards for Accessible Design?
15. Has the concept of “safe harbor” which was a part of the 2010 Standards for Accessible Design been incorporated into the Transition Plan?
16. When “Program Access Solutions” are used as the method to create access how are these solutions implemented? Please specifically state their impact on policy and staff operations.
17. It is required that interested parties are involved in Transition Plan decisions. Please discuss how this has been handled?
18. “Your Transition Plan is currently being updated. Please provide your comments and/or concerns, if any.
19. Was a self evaluation examining policies, practices and procedures conducted at an earlier date? If yes, please specify the date.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3698, Packet Page 3903
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 4
20. If recommendations were identified were they adopted and implemented?
21. Have new policies or programs been initiated since the completion of the previous self evaluation plan?
22. Were persons with disabilities and interested stakeholders consulted during the development of the previous self evaluation plan?
23. In conducting the Self Evaluation Plan and creating policies, was disability defined under the Fair Employment and Housing Act (Government Code, Section 12926 or the ADA)? (Explanation – the ADA covers people with a substantial limitation to a major life activity and Government Code Section 12926 covers persons with a limitation to a major life activity)
24. Has your Division, Department and/or Program provided Notice of its nondiscrimination policy? If yes, please describe how the Notice was disseminated and attach a copy of the Notice. .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3699, Packet Page 3904
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 5
25. Are policies in place that prohibit levying surcharges for the provision of auxiliary aides and services, i.e. readers, note takers, sign language interpreters, etc.? Please attach the policy.
26. Is the ADA Coordinator and emergency services personnel in communication on an ongoing basis concerning emergency
management?
NOTE: The US Department of Justice recommends the periodic publication of ADA notice, the use of TV/Radio, internet and other systemwide publications.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3700, Packet Page 3905
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 6 I. PHYSICAL ACCESS REQUIREMENTS A public
entity must examine each program to determine
whether any physical barriers to access exist.
(For ADA Coordinator and persons responsible for facilities acquisition or maintenance)
A. Identify steps to make programs physically accessible, i.e. restrooms in the area are accessible, doorways and paths into and around public offices and meeting rooms are wide enough for wheelchairs, etc. when viewed in their entirety. Please provide any comments or concerns, if any.
B. Structural changes are to be reported to the Building department and included in the overall Transition Plan for the City. Please provide any comments and/or concerns, if any.
C. Has the placement of furniture been considered as a potential barrier?
1. Is the use of furnishings which make it difficult or impossible for wheelchair users to pass through a given space avoided?
2. Are waiting rooms over-furnished, thus preventing
wheelchair users from having a place to be when waiting for appointments?
3. Are bulletin boards and brochure racks too high to be used by persons with disabilities?
4. Are items placed in areas immediately adjacent to the latch side of doorways in the pull direction?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3701, Packet Page 3906
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 7 II. REVIEW POLICIES AND PRACTICES TO
DETERMINE IF ANY EXCLUDE OR LIMIT
PARTICIPATION OF INDIVIDUALS WITH
DISABILITIES IN ITS PROGRAMS, ACTIVITIES OR
SERVICES.
A. Modify policies or practices.
B. Identify policy modifications to be implemented or submit justifications for those policies or practices which cannot be modified.
Example:
Can a blind person vote with the same degree of privacy and independence afforded sighted individuals?
Questions:
1. Are program eligibility requirements minimal?
2. Is each program eligibility requirement consistent with the business necessity of program administration? Would the removal of the requirement lead to a compromise of the
program’s functioning?
3. Are persons with disabilities receiving services provided in an integrated setting? If no, please discuss the program’s service model.
4. Do services provided through a third party contractor prohibit discrimination based on disability?
5. What methods could a complainant use to resolve an access issue related to a contract service provider?
6. Are policies in place that prohibit levying surcharges for the provision of auxiliary aides and services, i.e. readers, note
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3702, Packet Page 3907
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 8 takers, sign language interpreters, etc.? Please attach the policy.
7. Has your Division, Department and/or Program provided notice of its non-discrimination policy? If yes, please describe how the notice was disseminated.
8. Has your City reviewed its service animal policy since Federal Regulations changed Service Animal Access
Requirements in 2010? If a policy exists, please attach.
9. Do you have a policy and procedure to be used in analyzing “Direct Threat” to others? If yes, has this policy been updated since 2010? If the policy exists, please attach.
10. Have you developed guidance to be used within City
controlled property that addresses the use of motorized devices, other than wheelchairs, which are used for mobility? If the document exists, please attach.
11. Is a policy and procedure in place to ensure that features related to accessibility, such as elevators, lifts and other items that contribute to access to persons with disabilities are given the highest priority for repair when out of order? How is this policy disseminated to maintenance staff?
12. Is there a policy in place to enable persons to request a modification of City policy to create access for persons with disabilities? If a policy exists, please attach.
Law Enforcement:(For Police Department Only)
13. Has the US Department of Justice Role Call training videos been utilized to orient sworn officers to the appropriate interaction with persons with disabilities in law enforcement situations?
14. Are sign language interpreters available to support officers in public interactions?
15. Are TTY communication systems available on emergency telephone lines?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3703, Packet Page 3908
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 9
16. Has staff been trained in the appropriate use of TTYs? If yes, when was the last training date?
17. Is TTY training a part of the orientation for dispatch staff?
18. How are service animals handled when their owner is arrested?
19. How are motorized wheelchairs or other heavy mobility devices transported at the point of arrest?
20. When holding an inmate what is the procedure to ensure that medical equipment and medications are made available in a timely fashion?
21. How do officers ensure that persons with cognitive
disabilities or hearing impairments understand information communicated to them?
III. Review policies to ensure effective communication
systems exists with applicants, participants, staff and members of the public, particularly individuals with
disabilities.
A. Telephone communication
B. Telephone emergency services
C. TTY (Teletypewriter)
Questions:
1. How do persons who are deaf, hard of hearing or have a speech impairment communicate over the telephone with
(programs, services or activities offered by) your Division and/or Department?
2. If emergency response is part of your program what is the system for persons noted above to obtain emergency
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3704, Packet Page 3909
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 10 services?
3. When was the last time staff was trained in the use of your communication system for this population?
4. Are your web services accessible to persons who are blind or have low vision or learning disabilities?
5. Has the US Department of Justice guidance regarding
internet access been reviewed and used within your online programs?
6. Are forms available on your website for the public to complete? If yes, have these forms been tested by
individuals who use screen readers?
7. Do you use any touch screen systems when providing public service? If yes, please discuss how the services provided through this system are accessible for persons with visual impairment?
8. Do publications created by your division/department contain notice that they are available in alternative format upon request?
9. Is there a procedure for all staff having public contact regarding obtaining publications in alternative format when requested?
IV. Review policies to ensure provisions to secure services or equipment for:
A. Readers for individuals with visual impairments;
B. Interpreters for persons with hearing impairments; or
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3705, Packet Page 3910
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 11 C. A staff member available to take notes for an individual with a physical impairment
Questions:
1. Does your Division and/or Department provide auxiliary aides and services to persons with disabilities, to ensure equal program access?
2. Have resources been identified for the procurement of the following auxiliary aides and services: Sign language interpreter? Real time Captioner? Note taker? Braille? Large Print? Audio Tape? Assistive listening devices? Fragrance-free areas? Air purifiers? Remote video interpreting (RVI)? Qualified Reader?
3. Are staff who have public contact aware of the procedures of your Division and/or Department for securing resources in a timely manner to provide auxiliary aides and services?
4. Do all public meeting notices contain information relative to how auxiliary aides and services can be obtained?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3706, Packet Page 3911
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 12
5. Are videos purchased by your Division and/or Department always purchased with captioning included?
V. A review of procedures to evacuate individuals during an emergency. This may involve:
A. Installation of visual and audible warnings signals and special procedures for assisting individuals with disabilities from a facility during an emergency.
B. Using the EEOC guidance which was disseminated after 9/11 regarding identifying employees who have special needs in the event of an emergency.
Questions:
1. Is there an emergency evacuation plan for every site controlled by your Division and/or Department?
2. When was the last emergency drill?
3. Was a debriefing held after the drill to examine the effectiveness of the emergency response?
4. Did this debriefing include the provision of evacuation for employees and visitors with disabilities?
5. Has the EEOC guidance issued after 9-11 been used as a tool to identify staff that may need accommodation during an emergency?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3707, Packet Page 3912
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 13
6. After staff discloses the need for assistance during an emergency is the interactive process initiated?
7. Who is responsible for coordinating this process?
8. Is the ADA coordinator and safety personnel in
communication on an ongoing basis concerning emergency
management?
9. When was the last planning session held?
10. If emergency equipment has been purchased how frequently is emergency staff trained in its appropriate utilization?
11. How is emergency management equipment maintained?
12. Where in your building is emergency management
equipment stored?
13. Have evacuations in your building included the use of emergency evacuation equipment and persons with
disabilities? If not, please explain.
14. If emergency evacuation chairs are used in stairwells have they been tested to ensure that they can navigate corners within the stairwells without getting jammed?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3708, Packet Page 3913
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 14
15. Have provisions been made to ensure the stairwell can be utilized by emergency evacuation chairs, ambulatory building occupants and first responders simultaneously?
16. If it is necessary to reuse an emergency evacuation chair, what are the plans for the first person who is evacuated from the site regarding where they will be after the chair is taken back to the building?
17. Have first responders been consulted concerning your building’s plan for emergency management of persons with disabilities?
18. Have persons with disabilities in your building been informed of your emergency management plan?
19. If a buddy system is used for supportive persons with disabilities in an emergency please describe the system and its backups.
20. Is a system in place to shut down the HVAC system in the event hazardous chemical discharges occur outside the
building?
21. If an area of safe refuge is used please describe how the communication system between this area and the command
post is handled. Would this communication system be
effective for persons who are deaf or hard of hearing?
22. Does the command post have the capacity to communicate with first responders while they are in route to your building?
23. Is there a system in place to account for all personnel and visitors after the building has been evacuated?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3709, Packet Page 3914
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 15
24. Are individuals with visual impairments assisted in examining their immediate work area in the event of a bomb threat?
25. Would the facility (or part thereof) housing your program be used as a Mass Care Shelter in the event of a
communitywide disaster?
26. Have arrangements been made to obtain medications and durable medical supplies during a community-wide event? VI. A review of written and audio-visual materials to ensure that individuals with disabilities are not portrayed in an offensive or demeaning manner.
Questions:
1. Has a review of publications and audio visual material of your Divisions and/or Departments been made to ensure
that persons with disabilities are not viewed in an offensive or demeaning manner?
2. Has this review included an examination of language to ensure that: First person language is used? Offensive terms such as “handicapped”, “suffering from”, “victim of”, etc are not used?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3710, Packet Page 3915
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 16
3. Has the review ensured that the disabled community is represented by depicting a variety of disabilities within the publications and audio-visual materials of your
Division/Department?
VII. If Division and/or Department operates historic
preservation programs, review policies to ensure
priority is given to methods that provide physical
access.
Questions:
1. Does the City operate a program in a site that is listed on the National Historic Registry, a state historic registry or a local government historic registry? If yes, is there an accessible route from the arrival point to the entrance of the program location?
2. If the standard ramp slope was not feasible, has the historic standard been used to evaluate the ramp slope?
3. Is there an accessible route into the site (may not be the same entrance used by the general public)?
4. Is there at least one accessible toilet facility (maybe unisex)? Note: Accessible routes are only required at the level of entrance.
The program contained within the site must be accessible to and useable by persons with disabilities, i.e. if it is a historic library building, persons with disabilities must be able to participate in all phases of the program provided therein.
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3711, Packet Page 3916
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 17 VIII. A review of policies to ensure that decisions concerning a fundamental alteration of a program, activity, or
service is made properly and expeditiously.
Questions:
1. Does your Division and/or Department have a policy and procedure to ensure that decisions made claiming
fundamental alteration, hardships are reviewed in a timely fashion? If yes, please attach this policy. Has this policy been reviewed and updated to reflect the changes within the 2010 regulations?
IX. Review policies and procedures to ensure that
individuals with mobility impairments are provided
access to public meetings and events.
Questions:
1. Are formal or informal access surveys conducted within sites used for public meetings, training or other events?
2. Who conducts these site surveys?
3. What survey tools do they use to evaluate the site in question?
4. What training have they had in this subject matter?
5. What action is taken when findings concerning accessibility are identified?
6. Do the surveys include evaluations of access to City facilities to which school field trips are organized?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3712, Packet Page 3917
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 18
7. Does your City sell tickets to events? If yes, has a ticketing policy been developed since the Federal Regulation update of 2010? If such a policy exists, please attach.
Note: These standards and questions are also applicable to emergency shelters and disaster recovery centers.
X. A review of employment practices to ensure they
comply with other applicable nondiscrimination
requirements – Section 504 of the Rehabilitation Act, the ADA regulation issued by the Equal Employment
Opportunity Commission and the California Fair
Employment and Housing Act
(for all Supervisors, Managers and HR Staff)
Questions:
Note: It is recommended that employment checklist be completed by the HR staff and all supervisors/managers)
1. Are openings advertised through organizations which
have a disability constituency, i.e. the Department of
Rehabilitation, Independent Living Centers, One Stop
Service Centers, and other disability based community
organizations?
2. Are essential and marginal functions of each position defined before advertising?
3. Is information regarding openings available to
perspective candidates in alternative format upon
request?
4. Do job bulletins announcing openings contain statements regarding the City’s non discrimination policy concerning persons with disabilities?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3713, Packet Page 3918
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 19
5. Do advertisements inform potential applicants that
reasonable accommodation may be provided as needed
and appropriate during the selection process?
6. Are selection activities planned around evaluating the candidate’s ability to perform the essential function of the job in question?
7. Do candidates know in advance the types of activities they will be expected to engage in during the selection process? For example, interviews, writing exercise or
inbox exercise?
8. Have interview-panel members been trained in disability etiquette and allowable selection question formation?
9. Are all selection activities conducted in accessible locations?
10. Are selection sites adjacent to public transportation routes when possible?
11. Is there a policy prohibiting supervisors and managers from making any employment decision based on
disability?
12. Is there a reasonable accommodation policy in place, which can be utilized during selection, provision of
benefits and privileges, and to enable employees to
perform essential functions of their positions?
13. Is the reasonable accommodation policy readily
accessible to potential candidates and staff?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3714, Packet Page 3919
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 20
14. Is assistance available for persons who may, because of their disability, be unable to independently fill out or complete the necessary forms for reasonable
accommodation?
15. Is the reasonable accommodation process based on the ADA, the Rehab Act of 1973 or the California Fair
Employment and Housing Act?
16. Is the criteria for eligibility for reasonable accommodation that of the Fair Employment and Housing Act?
17. Are disabilities evaluated in the unmitigated status?
18. Do policies exist that coordinate the reasonable
accommodation process with Worker’s Compensation?
19. Does the reasonable accommodation process require a multiple step interactive process?
20. Have persons responsible for administering the
reasonable accommodation process been trained to
facilitate the interaction noted in the question above?
21. Are medical inquiries made only when necessary and
only when job related and consistent with business
necessity?
22. Is all medical information stored in a secure file, separate from the official personnel file?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3715, Packet Page 3920
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 21
23. Is there a policy in effect prohibiting the use of
information regarding existing leave balances in the
selection process?
24. Have hiring supervisors been trained not to ask questions about or leading to information about person’s disability during interviews or reference checks?
25. Is there a system in place to transfer a person with a disability into a vacant position if necessary, during the reasonable accommodation process? If yes, is there a
specific length of time prescribed in which a vacant
position is sought?
26. Does the search for vacant positions only include
positions from within the department the person is
employed by, or is it institution-wide?
27. When a vacant position is identified is there a prohibition against requiring that the person receiving the
reasonable accommodation compete for the assignment?
28. Has reasonable accommodation been considered during planning for emergency management in all sites from
which the City conducts programs, services and
activities?
29. Has the EEOC Guidance memo used to assist employers in identifying reasonable accommodation needs during
emergency evacuation of employees been used?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3716, Packet Page 3921
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 22
30. Please discuss how confidentiality is maintained for all reasonable accommodation requests.
31. When equipment is purchased for reasonable
accommodation is the employees’ names used on
purchasing documents?
32. If reasonable accommodation is denied is the case
reviewed prior to issuance of the denial decision?
33. Is there an internal appeal process to address
reasonable accommodation disputes?
34. How often are duty statements reviewed and updated?
35. Does this review include documenting essential
functions?
36. Is a requested reasonable accommodation always in
place/resolved prior to the end of employee’s probation?
37. Is notice posted regarding the availability of the
reasonable accommodation program?
38. If drug testing is used, have the labs conducting the tests, been informed that they are not to report the use of
prescription medication?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3717, Packet Page 3922
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 23
39. Is a policy disseminated annually to all staff putting them on notice that there is a zero tolerance for disability discrimination and/or harassment?
40. If direct threat is documented and will affect an employee or applicant’s position is it reviewed prior to decision implementation?
41. Are personal service assistants used as readers,
interpreters or drivers as a form of reasonable
accommodation? If yes, is there a consistent policy
addressing support services, such as, feeding, toileting, or tracheotomy tube cleaning?
42. What system is in place to keep HR, civil rights, legal counsel and managers and supervisor current with the
developments and disability employment law?
43. Has staff been trained in the determination of undue burden?
44. When undue burden decisions are reached are they
reviewed prior to the issuance of the decision?
Name of respondent (if different from cover page):
____________________________________
Email Address and Telephone Number:
____________________________________
Survey Completion Date:
____________________________________
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3718, Packet Page 3923
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 24 XI. Review building and construction policies to ensure new facilities or alterations after January 26, 1992,
conform to Title II Standards and Regulations and the
California Building Code.
(for persons responsible for facilities construction or acquisition)
Questions:
1. Is policy in place to ensure that facilities obtained after January 26, 1992 conform to ADA access standards and
the prevailing version of the California Building Code?
2. Does this policy pertain to facility remodels?
3. Does this policy pertain to new construction?
4. Does this policy pertain to new leases and lease
renewals?
5. Is there a policy in place to ensure that facilities are not furnished or equipped in a manner that would create
barriers to access? If yes, please provide policy.
6. Are all projects in which facility improvements are made updated in the Transition Plan document/database?
7. Have staff responsible for acquiring new space or new leases been trained relative to access requirements?
8. Has your Division and/or Department received any
complaints concerning the access described within this
requirement? If yes, what was the content and
disposition of that complaint?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3719, Packet Page 3924
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 25
9. Does your facility operation include a policy designed to maintain in operable working condition accessible
features of facilities and equipment that are required to be accessible to and usable by persons with disabilities? Note: Isolated or temporary interruptions in service or access due to maintenance or repairs are permitted.
XII. Ensure that employees are familiar with policies and practices for the full participation of individuals with disabilities. If appropriate, provide training to
employees.
(for the ADA Coordinator & HR Staff)
Questions:
1. Has training for staff been provided to ensure a thorough understanding of the City’s (including your Division and/or Department) disability civil rights responsibilities and disability etiquette?
2. How often is this training conducted?
3. What are the objectives of the training?
4. Is the training incorporated in your new employee academy? XIII. If a Division and/or Department limits or denies
participation based on drug usage, make sure
practices do not discriminate against former drug
users, as opposed to individuals currently engaged in
illegal use of drugs.
Questions
1. Have policies regarding illegal drug usage been reviewed to ensure that they do not discriminate against former drug and alcohol users?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3720, Packet Page 3925
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 26 Name of respondent (if different from cover page):
____________________________________
Email Address and Telephone Number:
____________________________________
Survey Completion Date:
____________________________________
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3721, Packet Page 3926
TEMPLATE
City of Monterey Self Evaluation
3/27/2012 S a l l y S w a n s o n A r c h i t e c t s I n c . Page 27 SUMMARY – 28 Code of Federal Regulations;
Part 35 (Title II, Department of Justice) http://www.ada.gov/reg2.html Non-discrimination on the basis of disability in State and Local Government services
Title II covers all activities of State and local governments regardless of the entity's size or receipt of Federal funding. Title II requires public entities, such as the City of Monterey, give people with disabilities an equal opportunity to benefit from all of its programs, services and activities.
The City is required to follow specific architectural standards in the new construction and alteration of its buildings. Furthermore, the City must relocate programs or alternatively provide access in inaccessible older buildings, and communicate effectively with people who have hearing, vision, or speech disabilities. The City is not required to take actions that would result in undue financial and administrative burdens. However, the City is required to make reasonable modifications to policies, practices and procedures, where necessary, to avoid discrimination, unless the City can demonstrate that doing so would fundamentally alter the nature of the service, program or activity being provided.
Key Citations
Sub Part A – General
35.105 – Requirement for Self Evaluation;
35.106 – Requires Posting Notice of ADA compliance;
35.107 – Requires the Designation of Employee Responsible for Coordination of ADA Implementation Activities;
Sub Part B – General Requirements
35.130 – General Prohibition Against Discrimination Against Qualified Persons with Disabilities;
35.131 – The Act's application to people who use drugs illegally;
35.133 – Requirement to maintain accessible features;
35.134 – Prohibition against retaliation or coercion;
35.135 – Clarification that personal services and devices are not required; Subpart C Employment
35.140 – Employment cross references with 29CFR part 1630; Sub Part D. Program Accessibility
35.150 - Adopts the program accessibility concept found in Section 504 of the Rehab Act of 1973;
35.151 – Requires New Construction and Alterations meet accessibility requirements; Sub Part E. Communications
35.160(d)(1) – Requirement of the Provision of Auxiliary Aides and Services;
35.161 – TDD Requirement;
35.162 – Telephone Emergency Services;
35.162 – Information Signage Availability;
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3722, Packet Page 3927
TEMPLATE
I. A review of employment practices to ensure they
comply with other applicable nondiscrimination
requirements – Section 504 of the Rehabilitation Act, the ADA regulation issued by the Equal Employment
Opportunity Commission and the California Fair
Employment and Housing Act (See Employment
Checklist)
Questions:
Note: It is recommended that employment checklist be completed by the HR department
1. Are openings advertised through organizations which
have a disability constituency, i.e. the Department of
Rehabilitation, Independent Living Centers, One Stop
Service Centers, and other disability based community
organizations?
2. Are essential and marginal functions of each position defined before advertising?
3. Is information regarding openings available to
perspective candidates in alternative format upon
request?
4. Do job bulletins announcing openings contain statements regarding the City’s non discrimination policy concerning persons with disabilities?
5. Do advertisements inform potential applicants that
reasonable accommodation may be provided as needed
and appropriate during the selection process?
6. Are selection activities planned around evaluating the candidate’s ability to perform the essential function of the job in question?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3723, Packet Page 3928
TEMPLATE
7. Do candidates know in advance the types of activities they will be expected to engage in during the selection process? For example, interviews, writing exercise or
inbox exercise?
8. Have interview-panel members been trained in disability etiquette and allowable selection question formation?
9. Are all selection activities conducted in accessible locations?
10. Are selection sites adjacent to public transportation routes when possible?
11. Is there a policy prohibiting supervisors and managers from making any employment decision based on
disability?
12. Is there a reasonable accommodation policy in place, which can be utilized during selection, provision of
benefits and privileges, and to enable employees to
perform essential functions of their positions?
13. Is the reasonable accommodation policy readily
accessible to potential candidates and staff?
14. Is assistance available for persons who may, because of their disability, be unable to independently fill out or complete the necessary forms for reasonable
accommodation?
15. Is the reasonable accommodation process based on the ADA, the Rehab Act of 1973 or the California Fair
Employment and Housing Act?
16. Is the criteria for eligibility for reasonable accommodation that of the Fair Employment and Housing Act?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3724, Packet Page 3929
TEMPLATE
17. Are disabilities evaluated in the unmitigated status?
18. Do policies exist that coordinate the reasonable
accommodation process with Worker’s Compensation?
19. Does the reasonable accommodation process require a multiple step interactive process?
20. Have persons responsible for administering the
reasonable accommodation process been trained to
facilitate the interaction noted in the question above?
21. Are medical inquiries made only when necessary and
only when job related and consistent with business
necessity?
22. Is all medical information stored in a secure file, separate from the official personnel file?
23. Is there a policy in effect prohibiting the use of
information regarding existing leave balances in the
selection process?
24. Have hiring supervisors been trained not to ask questions about or leading to information about person’s disability during interviews or reference checks?
25. Is there a system in place to transfer a person with a disability into a vacant position if necessary, during the reasonable accommodation process? If yes, is there a
specific length of time prescribed in which a vacant
position is sought?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3725, Packet Page 3930
TEMPLATE
26. Does the search for vacant positions only include
positions from within the department the person is
employed by, or is it institution-wide?
27. When a vacant position is identified is there a prohibition against requiring that the person receiving the
reasonable accommodation compete for the assignment?
28. Has reasonable accommodation been considered during planning for emergency management in all sites from
which the City conducts programs, services and
activities?
29. Has the EEOC Guidance memo used to assist employers in identifying reasonable accommodation needs during
emergency evacuation of employees been used?
30. Please discuss how confidentiality is maintained for all reasonable accommodation requests.
31. When equipment is purchased for reasonable
accommodation is the employees’ names used on
purchasing documents?
32. If reasonable accommodation is denied is the case
reviewed prior to issuance of the denial decision?
33. Is there an internal appeal process to address
reasonable accommodation disputes?
34. How often are duty statements reviewed and updated?
35. Does this review include documenting essential
functions?
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3726, Packet Page 3931
TEMPLATE
36. Is a requested reasonable accommodation always in
place/resolved prior to the end of employee’s probation?
37. Is notice posted regarding the availability of the
reasonable accommodation program?
38. If drug testing is used, have the labs conducting the tests, been informed that they are not to report the use of
prescription medication?
39. Is a policy disseminated annually to all staff putting them on notice that there is a zero tolerance for disability discrimination and/or harassment?
40. If direct threat is documented and will affect an employee or applicant’s position is it reviewed prior to decision implementation?
41. Are personal service assistants used as readers,
interpreters or drivers as a form of reasonable
accommodation? If yes, is there a consistent policy
addressing support services, such as, feeding, toileting, or tracheotomy tube cleaning?
42. What system is in place to keep HR, civil rights, legal counsel and managers and supervisor current with the
developments and disability employment law?
43. Has staff been trained in the determination of undue burden?
44. When undue burden decisions are reached are they
reviewed prior to the issuance of the decision?
Name of respondent (if different from cover page):
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3727, Packet Page 3932
TEMPLATE
____________________________________
Email Address and Telephone Number:
____________________________________
Survey Completion Date:
____________________________________
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3728, Packet Page 3933
TEMPLATE
SUMMARY – 28 Code of Federal Regulations;
Part 35 (Title II, Department of Justice) http://www.ada.gov/reg2.html Non-discrimination on the basis of disability in State and Local Government services
Title II covers all activities of State and local governments regardless of the entity's size or receipt of Federal funding. Title II requires public entities, such as the City of San Carlos, give people with disabilities an equal opportunity to benefit from all of its programs, services and activities.
The City is required to follow specific architectural standards in the new construction and alteration of its buildings. Furthermore, the City must relocate programs or alternatively provide access in inaccessible older buildings, and communicate effectively with people who have hearing, vision, or speech disabilities. The City is not required to take actions that would result in undue financial and administrative burdens. However, the City is required to make reasonable modifications to policies, practices and procedures, where necessary, to avoid discrimination, unless the City can demonstrate that doing so would fundamentally alter the nature of the service, program or activity being provided.
Key Citations
Sub Part A – General
35.105 – Requirement for Self Evaluation;
35.106 – Requires Posting Notice of ADA compliance;
35.107 – Requires the Designation of Employee Responsible for Coordination of ADA Implementation Activities;
Sub Part B – General Requirements
35.130 – General Prohibition Against Discrimination Against Qualified Persons with Disabilities;
35.131 – The Act's application to people who use drugs illegally;
35.133 – Requirement to maintain accessible features;
35.134 – Prohibition against retaliation or coercion;
35.135 – Clarification that personal services and devices are not required; Subpart C Employment
35.140 – Employment cross references with 29CFR part 1630; Sub Part D. Program Accessibility
35.150 - Adopts the program accessibility concept found in Section 504 of the Rehab Act of 1973;
35.151 – Requires New Construction and Alterations meet accessibility requirements; Sub Part E. Communications
35.160(d)(1) – Requirement of the Provision of Auxiliary Aides and Services;
35.161 – TDD Requirement;
35.162 – Telephone Emergency Services;
35.162 – Information Signage Availability;
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3729, Packet Page 3934 City of Monterey Self Evaluation - Staff Respondents
First Name Last Name Title Department Division Date
Rhonda Combs Services Manager Finance Sunday, June 03, 2012Brian McMinn Principal Engineer Plans/Public Works Capital Projects Anne McGrath
Communications & Outreach Manager
City Manager’s Office (CMO) and Communications & Outreach Office (C&OO) Monday, May 14, 2012 Andrew Miller Fire DepartmentJohn Kuehl Building Official ADA Coordinator Plans/Public Works Permit and Inspection George H. Helms General Services Superintendent Plans/Public Works General Services Monday, April 02, 2012 Maryrose Rinaudo
COMMUNITY SERVICES/RECREATION/SCHOLZE PARK CENTER
Shannon Leon
COMMUNITY SERVICES/RECREATION/SCHOLZE PARK CENTER Thursday, July 12, 2012 Lane Hayes Assistant City Attorney's Office Wednesday, June 20, 2012Scott Pryor Public Facilities Monterey Harbor & MarinaMarty Hart Sergeant Police Dept. Tuesday, April 17, 2012Claire Rygg Administrative Assistant Library Museum Division Tuesday, May 08, 2012Ksenia Kutow Coordinator Community Services/Recreation/Hilltop Park Center Wednesday, August 08, 2012 Rachel Deis Recreation Coordinator
Community Services/Recreation/Casanova Oak Knoll Park Center Wednesday, August 08, 2012 Nate Cota Recreation Coordinator
Community Services/ Recreation/ Monterey Youth Center Tuesday, August 07, 2012 SSA Inc. 3/12/2013
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3730, Packet Page 3935 SSA Project # 11037
City of Monterey - ADA Transition Plan
March 2013
Section: III Access Compliance Assessment
A. Appendix A: Facilities:
Sections
1) Buildings
2) Parks
3) Parking Lots
B. Appendix B: Public Rights-of-Way:
Sections
1) Intersections
2 Pedestrian Signals
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3731, Packet Page 3936 SSA Project # 11037
City of Monterey - ADA Transition Plan
March 2013
ACCESS COMPLIANCE SURVEY REPORTS
Navigation and Legend
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3732, Packet Page 3937 City of Monterey Access Compliance Survey Report Navigation and Legend Access Compliant Report Format
S a l l y S w a n s o n A r c h i t e c t s I n c .
City of Monterey Access Compliance Survey Report 108-0-1 Facility: City Hall Area: Exterior Part/Floor: On-Site
Address: 580 Pacific St. Building Maintenance
Existing Architectural Barrier
Item No. and Name and Proposed Solution Codes / Mitigation Qty Unit Cost Total 1 POT from West City Hall Entrance to South Entrance
11585 Sidewalk
• Access Barrier: PCODE EA05 50 JOB $45 $2250
Cross slope more than 1/4":12" (2%). ADAAG 4.6.3
CSAS 1129B.3.3
• As-built: 3.5% ADA 2010 502.4
• Proposed Solution:
Modify cross slope.
1. Item Number: Unique for each part/building in SSA Database.
2. Area / Location: Describes the building location / item title (e.g.: parking lot, room name).
3. As-Built: Description of as-is barrier based on applicable accessibility codes.
4. As-is Measurement: Existing conditions/dimensions.
5. Proposed Solution: Description of steps necessary to remove barrier and, if applicable, an interim solution or notes.
6. Codes / Info: - PCODE: specifies the relevant SSA database code. Database code plus suffix:
- REF: data shown for reference only [scope of work related to or covered by other item]; - NT: non-typical problem or solution.
- ADAAG, ADA ABA and CSAS: specifies applicable sections of Federal and State accessibility codes.
7. Qty: Number of units required.
8. Unit: Unit of measurement used to compute cost estimate. LF=linear feet; SF=square feet; JOB=lump sum.
9. Cost: Estimated cost of specific solution per one unit. (The final cost of the barrier-removal projects may exceed this estimate based on year of mitigation and design approach.)
10. Mitigation Schedule: Identifies the funding source, type, project year and name.
11. Total: Total estimated cost for removing identified barrier (multiplied Qty by Cost).
12. ID No: Specifies Facility Number – Area: 108 = Interior / 0 = Exterior – Part / Floor Number. 1 2 3 4 5 6 7 8 9 10 11 12
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3733, Packet Page 3938 City of Monterey Access Compliance Report – Public Rights-of-Way (Intersections) Navigation and Legend Access Compliant Report Format
Non compliant 1
City of Monterey Access Compliance Report – Public Rights-of-Way (Intersections) 100.123 Street ID# Survey Street Street ID# Cross Street
100 ANY STREET 123 ANY AVENUE
Orientation Ramp Type Existing Access Barrier Codes / Mitigation Info Measurements and Proposed Solution
NW Perpendicular
176 Ramp Slope
• As-Built Description: PCODE PC03A Width of Ramp (in) 48 Running slope of existing perpendicular curb ramp ADAPROW R303.2.1.1 Slope of Ramp (%) 12.8 is less than 5% or greater than 8.3%. CSAS 1127B.5.3 X Slope of the Ramp (%) 0.7 ADAAG 4.7.2; 4.8.2 Top Landing Length (in) 48
• As-is Measurement: 12.8% Top Landing Slope (%) 2.5
Top Landing X Slope (%) 1.2
• Proposed Solution: Left Flare (%) 10.5
Demolish existing and provide new, parallel curb Unit Cost $2,800.00 Right Flare (%) 15.2 ramp, including detectable warning surfaces, and Gutter Slope (%) 4.1 top and bottom landing as required. Gutter Lip (in) 0
Grooved Borders (in) 12
Truncated Domes Yes
Within Crosswalk Yes
1. Locator Number: Corresponds to the unique database record (one locator number per record).
2. Orientation: Corresponds to the specific corner/curb ramp in any given intersection, unique to each corner/curb ramp (in some cases there is more than one curb ramp per corner, or no curb ramp):
-NW, SW, SE, and NE are the most commonly used directions; -NWN, NWS, SWN, SWS, SEN, SES, NEN, and NES identify individual curb ramps in situations involving multiple curbs ramps at one corner; - I-NW, I-NE, I-SW, I-SE, etc, identify curb ramps located on medians and pedestrian refuge islands.
3. Specific Item: Category of accessible feature in which the barrier belongs.
4. Survey Street: Arterial/Primary street name with corresponding unique street identification number.
5. Ramp Type: Identifies the type of curb ramp (parallel, perpendicular, blended transition or no curb ramp, etc).
6. As-Built Description: Description of as-built barrier based on applicable accessibility codes.
7. As-is Measurement: Existing condition/dimension featured on the ramp measured as the most severe barrier on the particular ramp.
8. Proposed Solution: Description of steps necessary to remove barrier and, if applicable, an interim solution or notes.
9. Codes / Info: - PCODE: specifies the relevant SSA database code. Database code plus suffix:
-ADAPROW: U.S. Access Boards proposed accessibility guidelines for pedestrian facilities in the public rights of-way.
-CSAS: California State Accessibility Standards within Building Code. - ADAAG: Americans with Disabilities Act Accessibility Guidelines.
10. Unit Cost: Estimated cost specific solution per one unit. (The final cost of barrier removal may exceed this estimate based on the year of mitigation, design approach and chosen method of mitigation)
11. Cross Street: Cross/intersecting street name with corresponding unique street identification number.
12. Ramp Features: Features of ramp measured to determine accessibility.
13. Measurements: Existing condition/dimension determined for each ramp. -(in) measurement in inches
-(%) measurement in percentage grade
-Left measurements on the left side while facing the ramp -Right measurements on the right side while facing the ramp -BOLD text indicate non-compliant dimensions.
-Normal text indicate compliant dimensions
14. Compliancy: Identifies if curb ramp is compliant or not. Non-compliant curb ramps can be classified further into Non-Compliant 1 or Non-Compliant 2 based on the proposed solution. Non-Compliant 1 involves major work such as remove existing and replace with new curb ramp. Non-Compliant 2 involve minor work such as restriping crosswalk, etc. 1 2 3 4 5 6 7 8 9 10 11 12 13 14
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3734, Packet Page 3939 City of Monterey Access Compliance Report – Public Rights-of-Way (Pedestrian Signals) Navigation and Legend Access Compliant Report Format
Non compliant 1
City of Monterey Access Compliance Report – Public Rights-of-Way (Pedestrian Signal) 133.808 Street ID# Survey Street Street ID# Cross Street
133 ANY STREET 808 ANY AVENUE
Orientation Existing Access Barrier Codes / Mitigation Info Measurements and Proposed Solution
NW Clear Floor Space
176 • As-Built Description: PCODE PA19A Accessible Path (y/n) Yes The slope of the floor or ground surface at the ADAPROW R306.2.2 Clear Floor Space (y/n) Yes pedestrian signal device exceed 1:48 (2%). CSAS 1118B.4.1 Clear Floor Slope (%) 6.0 ADAAG 4.3.7 Clear Floor X Slope (%) 5.7
• As-is Measurement: 6.0% Button Height (in) 47
Button Reach (in) 0
• Proposed Solution: Button Diameter (in) 0.5
Modify or repave the ground surface as necessary Unit Cost $2,650.00 Button Pressure (lbs) 5 To provide slope(s) not exceeding the required 1:48 Closed Fist Operation (y/n) NO (2%) maximum in any direction. Visual Contrast (y/n) Yes Contrasting Color Bands (y/n) NO
Audible Walk Indicator (y/n) NO
Button Locator Tone (y/n) NO
Directional Information (y/n) Yes
1. Locator Number: Corresponds to the unique database record (one locator number per record).
2. Orientation: Corresponds to the specific corner in any given intersection, unique to each corner -NW, SW, SE, and NE are the most commonly used directions; -NWN, NWS, SWN, SWS, SEN, SES, NEN, and NES identify individual pedestrian signal system in situations involving multiple signal systems at one corner; - I-NW, I-NE, I-SW, I-SE, etc, identify pedestrian signal systems located on medians and pedestrian refuge
3. Specific Item: Category of accessible feature in which the barrier belongs. islands.
4. As-Built Description: Description of as-built barrier based on applicable accessibility codes.
5. As-is Measurement: Existing condition/dimension featured on the signal system measured as the most severe barrier on the particular signal system.
6. Survey Street: Arterial/Primary street name with corresponding unique street identification number.
7. Proposed Solution: Description of steps necessary to remove barrier and, if applicable, an interim solution or notes.
8. Codes / Info: -PCODE: specifies the relevant SSA database code. Database code plus suffix. -ADAPROW: US Access Board Draft Guidelines for accessible public rights-of-way. -CSAS: California State Accessibility Standards.
-ADDAG: Americans with Disability Act Accessibility Guidelines.
9. Unit Cost: Estimated cost specific solution per one unit. (The final cost of barrier removal may exceed this estimate based on the year of mitigation, design approach and chosen method of mitigation)
10. Cross Street: Cross/intersecting street name with corresponding unique street identification number.
11. Pedestrian Signal Features: Features of the pedestrian signal system measured to determine accessibility.
12. Measurements: Existing condition/dimension determined for each pedestrian signal system. -(in) measurement in inches
-(%) measurement in percentage grade
-BOLD text indicate non-compliant dimensions.
-Normal text indicate compliant dimensions
13. Street ID Number: Identifies street on which given intersection occurs.
14. Compliancy: Identifies if signal device is compliant or not. Non-compliant signal device can be classified further into NonCompliant 1 or Non-Compliant 2 based on the proposed solution. Non-Compliant 1 involves major work such as remove existing and replace with new signal device. Non-Compliant 2 involves minor work such as providing color coding.
1 2 3 4 5 6 7 8 9 10 11 12 13 14
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3735, Packet Page 3940 City of Monterey Access Compliance Report – Public Rights-of-Way (Intersections) Navigation and Legend Access Compliant Report Format
ADA Americans with Disabilities Act
ADAAG ADA Accessibility Guidelines
ADACO ADA-Coordinator
AFF Above finished floor
C.T.P. Contact third party
CA State of California
CDD Community Development Director
cl Center line
CMGR City Manager
CP Chief of Police
CSAS CA State Accessibility Standards
D.A. Designated accessible
Dep. Deputy
Dept. Rep Department representative
DF Drinking fountain
DH Department Head
Dir. Director
E East
E.D. Executive Director
E.F. Equivalent facilitation
F-B-F Facility-Building-Floor
FC Fire Chief
FD Finance Director
Fig. Figure
FM&O Facilities, Maintenance & Operations
FND Feminine napkin dispenser
FTD Feminine tampon dispenser
Gov. Government
HQ Headquarters
JOB per one job (lump sum)
Lab Laboratory
Lav Lavatory
lbs Pounds
LF Linear foot
MOD Modernization project
MoM Method of mitigation
MP Master priority
MRR Men’s restroom
N North
N.A.R. No action required
NE Northeast
NT Non-typical
NW Northwest
NWn Northwest: North side
NWs Northwest: South side
o.c. On center
O/R Official responsible
PAR Public Access Route
P.A. Physical alteration
P.M. Program modification
POT Path of travel
PROW Public Right of Way
PTD Paper towel dispenser
PWD Public Works Director
Qty Quantity
REF Reference
S South
SCD Seat cover dispenser
SD Soap dispenser
sec. Second
Sec. Section
SE Southeast
SF Square foot
SW Southwest
TBD To be determined
up Ramp or stair direction up
W West
WC Water Closet
WRR Women’s Restroom
STANDARDS
PERPENDICULAR CURB RAMP
Width of Ramp 48” wide min.
Slope of Ramp 8.3% max.
X Slope of the Ramp 2.0% max.
Top Landing Length 48” long min.
Top Landing Slope 2.0% max.
Top Landing X Slope 2.0% max.
Left Flare 10% max.
Right Flare 10% max.
Gutter Slope 5% max.
Gutter X Slope 2% max.
Gutter Lip 0” lip (Flush)
Grooved Borders 12” grooves
Truncated Domes 36” deep x width of ramp
Within Crosswalk 48” within crosswalk
PARALLEL CURB RAMP
LEFT RIGHT
Width of Ramp 48” wide min. 48” wide min
Slope of Ramp 8.3% max. 8.3% max.
X Slope of the Ramp 2.0% max. 2.0% max.
Top Landing X Slope 2.0% max. 2.0% max.
Bottom Landing Length 48” long x 48” wide
Bottom Landing Slope 2.0% max.
Bottom Landing X Slope 2.0% max.
Gutter Slope 5% max.
Gutter X Slope 2% max.
Gutter Lip 0” lip (Flush)
Grooved Border 12” grooves (on both sides)
Truncated Domes 36” deep x width of ramp
Within Crosswalk 48” within crosswalk
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3736, Packet Page 3941 SSA Project # 11037
City of Monterey - ADA Transition Plan
March 2013
ACCESS COMPLIANCE SURVEY REPORTS
Barrier Location Plans
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3737, Packet Page 3942 Exterior - On-Site
101
101-0-1
Senior Center
101-0-1
280 Dicke.
Monterey Ca
93940
Senior Center
Elm st.
Magnolia Ave.
9 8 7 6 5 1
2 3
4 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3738, Packet Page 3943 Interior - Basement & Ground Floor
101
101-1-1
Senior Center
101-1-0&1
280 Dickman Ave.
Monterey Ca
93940
Senior Center
Elm st.
Magnolia Ave.
101-1-0
1 754
3 16
151011
12 9
6 1314
8 21
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3739, Packet Page 3944 Exterior - On-Site
102
102-0-1 Coporation Yard
102-0-1
Ryan Ranch Rd.
Monterey Ca
93940
Coporation Yard
Elm st.
Magnolia Ave.
5 2 1 4 3
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3740, Packet Page 3945 Exterior - On-Site
103
103-0-1 Building Maintenance POM Shop
103-0-1
POM 268,
Presidio of
Monterey
Building
Maintenop
1 Interior Items
111
BLDG #1 1, 2 & 3BLDG #2 1
BLDG #4 1 & 2BLDG #3 1 - 9
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3741, Packet Page 3946 Exterior - On-Site
104
104-0-1 Cannery Row Fishing Shack
104-0-1
Cannery Row
Monterey Ca
93940
Cannery
Fishing Sha
Elm st.
Magnolia Ave.
1 3
2 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3742, Packet Page 3947 Exterior - On-Site
105
105-0-1 Cemetery Office
105-0-1
Fremont &
Camino Aguajito
Monterey Ca 93940
Cemeterey
Office
Elm st.
Magnolia Ave.
2 5
4 1
3 6
7 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3743, Packet Page 3948 Exterior - On-Site
108
108-0-1 City Hall Complex
108-0-1
580 Pacific St
Monterey, CA
93940
City Hall Complex
14172016
24 181913231522
7 11
8 2110
96 12
45321
25 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3744, Packet Page 3949 Interior - Ground Floor
108
108-1-1 City Offices
108-1-1
424 Madison St
Monterey, CA
93940
City Offices
3 1
2 4
56 7
9 8 12 11 10 18 17
16 151314
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3745, Packet Page 3950 Interior - Second Floor
108
108-1-2 City Offices
108-1-2
424 Madison St
Monterey, CA
93940
City Offices
3 1
2 4
5 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3746, Packet Page 3951 Interior - Ground Floor
108
108-2-1 Old Monterey Jail & Colton Hall
108-2-1
580 Pacific St
Monterey, CA
93940 Elm st.
Magnolia Ave.
Old Monterey Jail
& Colton Hall
1 6 5
4 3 2 7
9 8
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3747, Packet Page 3952 Interior - Second Floor
108
108-2-2 Old Monterey Jail & Colton Hall
108-2-2
580 Pacific St
Monterey, CA
93940
Old Monterey Jail
& Colton Hall
3 2
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3748, Packet Page 3953 Exterior - On-Site
109
109-0-1
109-0-1
1 Portola Plaza
Monterey, CA
93940
Conference
Center
Conference Center
7 8
9 11 6
4 10 3 1 2
5 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3749, Packet Page 3954 Interior - Ground Floor
109
109-1-1
109-1-1
1 Portola Plaza
Monterey, CA
93940
Conference
Center
Conference Center
20 19
16 17
18 2
3 15
1413
11 12
10 9
1 4
8 6 7 5 Sally Swanson Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3750, Packet Page 3955 Interior - Second Floor
109
109-1-2
109-1-2
1 Portola Plaza
Monterey, CA
93940
Conference
Center
Conference Center
4 7
6 5
3 2
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3751, Packet Page 3956 Interior - Third Floor
109
109-1-3
109-1-3
1 Portola Plaza
Monterey, CA
93940
Conference
Center
Conference Center
3 6
7 9
5 8
1 2
10 4
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3752, Packet Page 3957 Elm st.
Exterior - On Site
110
110-0-1
110-0-1
353
Camino El Estero
Monterey, CA
93940
Construction
Management
Construction Management
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3753, Packet Page 3958 Interior - Ground Floor
110
110-1-1
110-1-1
353
Camino El Estero
Monterey, CA
93940
Construction
Management
Construction Management
4 2
3 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3754, Packet Page 3959 Exterior - On-Site
111
111-0-1
111-0-1
800 Cannery Row
Monterey, CA
93940
Doc’s Lab
Doc’s Lab
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3755, Packet Page 3960 Elm st.
Exterior - On-Site
112
112-0-1
112-0-1
Madison & Dutra
Monterey, CA
93940
Employee Lounge
Employee Lounge
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3756, Packet Page 3961 Elm st.
Interior - Ground Floor
112
112-1-1
112-1-1
Madison & Dutra
Monterey, CA
93940
Employee Lounge
Employee Lounge
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3757, Packet Page 3962 Elm st.
Exterior - On-Site
113
113-0-1
113-0-1
610 Pacific St.
Monterey, CA
93940
Fire and
Police Annex
Fire and Police Annex
FIRE STATION No. 1
POLICE DEPARTMENT 6
3 1
7 8
11 10
2 5
4 12
9 13
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3758, Packet Page 3963 Elm st.
Interior - Ground Floor
113
113-1-1
113-1-1
610 Pacific St.
Monterey, CA
93940
Police Admin. &
E.O.C. Operation
Police Admin. & E.O.C. Operation
1 3
4 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3759, Packet Page 3964 Interior - Ground Floor
113
113-2-1
113-2-1
610 Pacific St.
Monterey, CA
93940
Fire
Administration
Fire Administration
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3760, Packet Page 3965 Interior - Ground Floor
114
114-1-1
114-1-1
Pacific & Madison
Monterey, CA
93940
Fire Station
No. 1
Fire Station No. 1
5 4
6 1 2 3
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3761, Packet Page 3966 Exterior - On-Site
115
115-0-1
115-0-1
558/582
Hawthorne St.
Monterey, CA
93940
Fire Station No. 2
Fire Station No. 2
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3762, Packet Page 3967 Interior - Ground Floor
115
115-1-1
115-1-1
558/582
Hawthorne St.
Monterey, CA
93940
Fire Station No. 2
Fire Station No. 2
1 2
4 3
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3763, Packet Page 3968 Interior - Ground Floor
116
116-1-1
116-1-1
401 Dela Vina
Monterey, CA
93940
Fire Station No. 3
Fire Station No. 3
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3764, Packet Page 3969 Elm st.
Exterior - On-Site
117
117-0-1
117-0-1
526 Pierce St.
Monterey, CA
93940
Gordon House
Gordon House
1 2 3
4 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3765, Packet Page 3970 Elm st.
Interior - Ground Floor
117
117-1-1
117-1-1
526 Pierce St.
Monterey, CA
93940
Gordon House
Gordon House
1 6
2 7
3 5
4 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3766, Packet Page 3971 Exterior - On-Site
118
118-0-1
118-0-1
Del Monte &
Figueroa
Monterey,
CA 93940
Harbor Master
Harbor Master
2 4 5
1 3
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3767, Packet Page 3972 Interior - Ground Floor
118
118-1-1
118-1-1
Del Monte &
Figueroa
Monterey,
CA 93940
Harbor Master
Harbor Master
2 4 5
3 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3768, Packet Page 3973 Interior - Second Floor
118
118-1-2
118-1-2
Del Monte &
Figueroa
Monterey,
CA 93940
Harbor Master
Harbor Master
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3769, Packet Page 3974 Exterior - On-Site
119
119-0-1
119-0-1
417 Figueroa
Monterey, CA
93940
Harbor Patrol
Harbor Patrol
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3770, Packet Page 3975 Elm st.
Exterior - On-Site
120
120-0-1
120-0-1
669 Van Buren
Monterey, CA
93940
Housing &
Property
Management
Housing & Property Management
3 5
1 2
4 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3771, Packet Page 3976 Elm st.
Interior - Ground Floor
120
120-1-1
120-1-1
669 Van Buren
Monterey, CA
93940
Housing &
Property
Management
Housing & Property Management
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3772, Packet Page 3977 Elm st.
Exterior - On-Site
123
123-0-1
123-0-1
512 Pierce St.
Monterey, CA
93940
Ketcham House
Ketcham House
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3773, Packet Page 3978 Elm st.
Interior - Ground Floor
123
123-1-1
123-1-1
512 Pierce St.
Monterey, CA
93940
Ketcham House
Ketcham House
1 2
3 4
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3774, Packet Page 3979 Elm st.
Exterior - On-Site
124
124-0-1
124-0-1
625 Pacific St.
Monterey, CA
93940
Library
Library
3 6
1 542
Book Mobile
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3775, Packet Page 3980 Elm st.
Interior - Basement Floor
124
124-1-0
124-1-0
625 Pacific St.
Monterey, CA
93940
Library
Library
21 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3776, Packet Page 3981 Elm st.
Interior - Ground Floor
124
124-1-1
124-1-1
625 Pacific St.
Monterey, CA
93940
Library
Library
1312141110
9 1516
57138246
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3777, Packet Page 3982 Elm st.
Interior - Second Floor
124
124-1-2
124-1-2
625 Pacific St.
Monterey, CA
93940
Library
Library
4653721
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3778, Packet Page 3983 Exterior - On-Site
125
125-0-1
125-0-1
5 Custom
House Plaza
Monterey, CA
93940
Maritime
Museum
Maritime Museum
Community
Room
1 3
1, 2 & 3
2 4
1 Interior Items
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3779, Packet Page 3984 Elm st.
Exterior - On-Site
126
126-0-1
126-0-1
399 Madison
Monterey, CA
93940
Temporary Office
Facility (Modular)
Temporary Office Facility (Modular)
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3780, Packet Page 3985 Elm st.
Interior - Ground Floor
126
126-1-1
126-1-1
399 Madison
Monterey, CA
93940
Temporary Office
Facility (Modular)
Temporary Office Facility (Modular)
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3781, Packet Page 3986 Exterior - On-Site
128
128-0-1
128-0-1
Presidio of
Monterey
Monterey, CA
93940
Presidio
Museum
Presidio Museum
2 1
4 5
3 6
7 9
8 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3782, Packet Page 3987 Interior - Ground Floor
128
128-1-1
128-1-1
Presidio of
Monterey
Monterey, CA
93940
Presidio
Museum
Presidio Museum
1 2
3 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3783, Packet Page 3988 Exterior - On-Site
129
129-0-1
129-0-1
380 Alvarado
Monterey, CA
93940
Osio
Rodriquez Adobe
Osio Rodriquez Adobe
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3784, Packet Page 3989 Interior - Ground Floor
134
134-1-1
134-1-1
546 Dutra St.
Monterey, CA
93940
Vasquez Adobe
Recreation Dept.
Vasquez Adobe Recreation Dept.
65 132
4 7 8
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3785, Packet Page 3990 Interior - Second Floor
134
134-1-2
134-1-2
546 Dutra St.
Monterey, CA
93940
Vasquez Adobe
Recreation Dept.
Vasquez Adobe Recreation Dept.
1 23
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3786, Packet Page 3991 Exterior - On-Site
136
136-0-1
136-0-1
314 Del Monte
Avenue
Monterey, CA
93940
Monterey
Sport Center
Monterey Sport Center
456
312
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3787, Packet Page 3992 136
136-1-1
136-1-1
314 Del Monte
Avenue
Monterey, CA
93940
Monterey
Sport Center
Monterey Sport Center
Interior - Ground Floor
7 6 8 4 10 11 1 2 15 16
5 9 12 3 13 19 17 14 18
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3788, Packet Page 3993 Interior - Second Floor
136
136-1-2
136-1-2
314 Del Monte
Avenue
Monterey, CA
93940
Monterey
Sport Center
Monterey Sport Center
5 6 4
1 3 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3789, Packet Page 3994 Exterior - On Site
137
137-0-1
137-0-1
Oliver St.
Monterey, CA
93940
Wharf I
Wharf I
2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3790, Packet Page 3995 Interior - Ground Floor
137
137-1-1
137-1-1
Oliver St.
Monterey, CA
93940
Wharf I
Wharf I
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3791, Packet Page 3996 Interior - Ground Floor
138
138-1-1
138-1-1
Wharf II
Monterey, CA
93940
Wharf IIBeach Restroom
Wharf II Beach Restroom
2 3
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3792, Packet Page 3997 Interior - Ground Floor
138
138-2-1
138-2-1
Wharf II
Monterey, CA
93940
Wharf II End
Restroom
Wharf II End Restroom
2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3793, Packet Page 3998 Interior - Ground Floor
138
138-3-1
138-3-1
Wharf II
Monterey, CA
93940
Wharf II
Boater’s Restroom
Wharf II Boater’s Restroom
2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3794, Packet Page 3999 Elm st.
Exterior - On-Site
139
139-0-1
139-0-1
735 Pacific St.
Monterey, CA
93940
City Offices
City Offices
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3795, Packet Page 4000 Elm st.
Interior - Ground Floor
139
139-1-1
139-1-1
735 Pacific St.
Monterey, CA
93940
City Offices
City Offices
4 3 6 2 7 8 9 10
5 1 12 14 13 11
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3796, Packet Page 4001 Elm st.
Exterior - On Site
140
140-0-1
140-0-1
777 Pearl St.
Monterey, CA
93940
Monterey
Youth Center
Monterey Youth Center
15 2
34 Dance Studio
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3797, Packet Page 4002 Elm st.
Interior - Ground Floor
140
140-1-1
140-1-1
777 Pearl St.
Monterey, CA
93940
Monterey
Youth Center
Monterey Youth Center
3 4
1 2
5 7
6 8
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3798, Packet Page 4003 Elm st.
Exterior - On Site
141
141-0-1
141-0-1
401
Camino El Estero
Monterey, CA
93940
Visitor Center
Visitor Center
1 2
3 5
4 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3799, Packet Page 4004 Elm st.
Interior - Ground Floor
141
141-1-1
141-1-1
401
Camino El Estero
Monterey, CA
93940
Visitor Center
Visitor Center
2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3800, Packet Page 4005 Interior - Ground Floor
145
142-1-1
142-1-1
542 Archer St.
Monterey, CA
93940
Archer Community Center
Archer
Community
Center
6 5 4 3 2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3801, Packet Page 4006 Interior - Ground Floor
143
143-1-1
143-1-1
601 Wave St.
Monterey, CA
93940
Cannery Row
Parking Garage
Office
Cannery Row Parking Garage Office
1 3 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3802, Packet Page 4007 Interior - Second Floor
143
143-1-2
143-1-2
601 Wave St.
Monterey, CA
93940
Cannery Row
Parking Garage
Office
Cannery Row Parking Garage Office
1 4 5 6 2
3 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3803, Packet Page 4008 Interior - Ground Floor
144
144-1-1
144-1-1
735 Ramona St.
Monterey, CA
93940
Casanova Oak
Knoll Center
Casanova Oak Knoll Center
5 4 2 3 1 7
9 8 6
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3804, Packet Page 4009 Interior - Ground Floor
145
145-1-1
145-1-1
871 Jessie St.
Monterey, CA
93940
Hilltop Center
Hilltop Center
6 5 4 3 2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3805, Packet Page 4010 Interior - Second Floor
145
145-1-2
145-1-2
871 Jessie St.
Monterey, CA
93940
Hilltop Center
Hilltop Center
2 3
1 13 14 11
12 4 5 7 6 8 9
10 15 3
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
06/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3806, Packet Page 4011 Interior - Ground Floor
147
147-1-1
147-1-1
Monterey, CA
93940
Traffic Engineering
Traffic Engineering
FLOOR PLANS NOT PROVIDED
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
08/27/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3807, Packet Page 4012 Exterior - On-Site
1001
1001-0-1
Archer Park
1001-0-1
Elm st.
Magnolia Ave.
Archer Park
542 Archer Street
Monterey, CA
576
1432
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3808, Packet Page 4013 Exterior - On-Site
1004
1004-0-1
Casanova Oak Knoll Park
1004-0-1
Casanova Oak
Knoll Park
735 Ramona St.
Monterey, CA
354
12 6
12879
10 11
13 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3809, Packet Page 4014 Exterior - On-Site
1005
1005-0-1 Cypress Park
1005-0-1
Elm st.
Magnolia Ave.
Cypress Park
Cypress &
Hoffman St.
Monterey, CA
45386972
1 10
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3810, Packet Page 4015 Exterior - On-Site
1006
1006-0-1
Deer Flats Park
1006-0-1
Elm st.
Deer Flats Park
Deer Forest Road
Monterey, CA
435
162
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3811, Packet Page 4016 Exterior - On-Site
1007
1007-0-1
Don Dahvee Park
1007-0-1
Elm st.
Don Dahvee Park
Fremont St. &
Iris Canyon Rd.
Monterey, CA
7 564
3 2
1 9
8 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3812, Packet Page 4017 Exterior - On-Site
1008
1008-0-1 El Estero Park Complex No. 1
1008-0-1
Elm st.
Magnolia Ave.
777 Pearl Street
Monterey, CA
El Estero Park
Complex No. 1
3 1
2 5
35 36
4 34
2225
2423
8 7
6 9
11 10
12 13
14 20
18 19
17 1516
21 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3813, Packet Page 4018 Exterior - On-Site
1008
1008-0-1
1008-0-1
Elm st.
Magnolia Ave.
777 Pearl Street
Monterey, CA
El Estero Park
Complex No. 2
El Estero Park Complex No. 2
29 27
28 30
31 32
33 26
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3814, Packet Page 4019 Exterior - On-Site
1010
1010-0-1
Peter J. Ferrante Park
1010-0-1
Peter J.
Ferrante Park
Encina & Palo
Verde St.
Monterey, CA
2813
9 10
7564
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3815, Packet Page 4020 Exterior - On-Site
1011
1011-0-1
Fisherman Flats Park
1011-0-1
Elm st.
Magnolia Ave.
Fisherman
Flats Park
Via Isola &
San Vito Circle
Monterey, CA
3 5412
No. 1
No. 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3816, Packet Page 4021 Exterior - On-Site
1012
1012-0-1 Hilltop Park
1012-0-1
Elm st.
Magnolia Ave.
Hilltop Park
871 Jessie Street
Monterey, CA
16 15 14 13 12 1 4 3
2 7 8 9 10 11 5 6
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3817, Packet Page 4022 Exterior - On-Site
1013
1013-0-1
Hoffman Park
1013-0-1
Elm st.
Magnolia Ave.
Hoffman Park
542 Archer Street
Monterey, CA
3846
5127
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3818, Packet Page 4023 Exterior - On-Site
1014
1014-0-1
Jacks Ball Park
1014-0-1
Elm st.
Magnolia Ave.
Jacks Ball Park
Franklin &
Figueroa St.
Monterey, CA
5 1
2 4
3 9
8 6
7 10
11 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3819, Packet Page 4024 Exterior - On-Site
1016
1016-0-1 Laguna Grande Regional Park
1016-0-1
Elm st. Del Monte & Virgin Avenue Monterey, CA
Laguna Grande
Regional Park
8 1 4 5 7
9 2 3 6
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3820, Packet Page 4025 Exterior - On-Site
1017
1017-0-1 Laguna Grande Court Park
1017-0-1
Elm st.
Magnolia Ave.
Laguna Grande
Court Park
Kolb Avenue
Monterey, CA
1 2
3 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3821, Packet Page 4026 Exterior - On-Site
1019
1019-0-1
Larkin Park
1019-0-1
Elm st.
Magnolia Ave.
Larkin Park
Monroe &
Clay Street
Monterey, CA
541732
68 9
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3822, Packet Page 4027 Exterior - On-Site
1021
1021-0-1
Montecito Park
1021-0-1
Elm st.
Magnolia Ave.
Montecito Park
Montecito &
Dela Vina St.
Monterey, CA
1 5
7623
4 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3823, Packet Page 4028 Exterior - On-Site
1022
1022-0-1 Monterey Bay Park
1022-0-1
Elm st.
Monterey Bay
Park
Del Monte Avenue
Monterey, CA
8 7 2 1 3 4 5 6
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3824, Packet Page 4029 Exterior - On-Site
1023
1023-0-1
Oak Newton Park
1023-0-1
Oak Newton
Park
Oak & Newton St.
Monterey, CA
Proposed Ramp
1 2 5 4 3 8 9 10 11
13 12 6 7
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3825, Packet Page 4030 Exterior - On-Site
1024
1024-0-1 Quarry Park
1024-0-1
Elm st.
Magnolia Ave.
Quarry Park
Via Gayuba &
Via Del Pinar
Monterey, CA
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3826, Packet Page 4031 Exterior - On-Site
1027
Ryan Ranch Park
Park Road &
Ryan Ranch Rd.
Monterey, CA
Ryan Ranch Park 1027-0-1
1027-0-1
67 4521
3 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3827, Packet Page 4032 Exterior - On-Site
1028
1028-0-1
San Carlos Beach Park
1028-0-1
San Carlos
Beach Park
Cannery Row at
Reeside Avenue
Monterey, CA
1 2
9 10 8 4 3 5 6 7 11
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3828, Packet Page 4033 Exterior - On-Site
1029
1029-0-1
Scholze Park
1029-0-1
Elm st.
Magnolia Ave.
Scholze Park
280 Dickman St.
Monterey, CA
43 21
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3829, Packet Page 4034 Exterior - On-Site
1030
1030-0-1
Fishermans Shoreline Park
1030-0-1
Fishermans
Shoreline Park
Fishermans Wharf
& Coast Guard Pier
Monterey, CA
76 8 9
4 5
123
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3830, Packet Page 4035 Exterior - On-Site
1031
1031-0-1
Soldier Field
1031-0-1
Soldier Field
Infantry Street &
Stillwell Avenue
Monterey, CA
8 141617
76 13
9 10
121118
12 15
453
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3831, Packet Page 4036 Exterior - On-Site
1032
1032-0-1 Spray Ave. Tot Lot
1032-0-1
Elm st.
Spray Ave.
Tot Lot
Spray Avenue
Monterey, CA
3 2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3832, Packet Page 4037 Exterior - On-Site
1033
1033-0-1
Veterans Memorial Park
1033-0-1
Veterans
Memorial Park
Skyline Drive
at Veterans Drive
Monterey, CA
10 11
4 1
15 16
14 13
12 6
8 7
9 2
3 18
17 5
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3833, Packet Page 4038 Exterior - On-Site
1034
1034-0-1
Via Paraiso Park
1034-0-1
Via Paraiso Park
Via Paraiso &
Herrmann Drive
Monterey, CA
10 9
2 13
14 15
11 8
7 1
3 5
4 6
12 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3834, Packet Page 4039 Exterior - On-Site
1035
1035-0-1 Whispering Pines Park
1035-0-1
Whispering
Pines Park
Pacific &
Alameda Street
Monterey, CA
5 67
10 3
11 1
2 4
13 12 9
8 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
6/15/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelInaccessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3835, Packet Page 4040 Exterior - On-Site
1 1-0-1 Parking Lot 1
1-0-1
Elm st. Waterfront-West
Magnolia Ave.
Parking Lot 1
231
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3836, Packet Page 4041 Exterior - On-Site
2 2-0-1 Parking Lot 2
2-0-1
WaterfrontEast/Marina
Parking Lot 2
Elm st.
Magnolia Ave.
1243
56 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3837, Packet Page 4042 Exterior - On-Site
3 3-0-1 Parking Lot 3
3-0-1
Rear-City Hall
Parking Lot 3
Elm st.
Magnolia Ave.
132
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3838, Packet Page 4043 Exterior - On-Site
4 4-0-1 Parking Lot 4
4-0-1
Franklin/
Van Buren
Parking Lot 4
Elm st.
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3839, Packet Page 4044 Exterior - On-Site
5 5-0-1 Parking Lot B
5-0-1
Calle Principal/
Pearl
Parking Lot B
Elm st.
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3840, Packet Page 4045 Exterior - On-Site
6 6-0-1 Parking Lot #6
6-0-1
Parking Lot #6
Elm st. Entrance Wharf I
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3841, Packet Page 4046 Exterior - Upper Floor
7 7-0-2 Calle Principal Parking Garage
7-0-2
438 Calle Principal
Monterey, CA
93940
Calle Principal
Parking Garage
Elm st.
Magnolia Ave.
213
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3842, Packet Page 4047 Interior - Lower Floor
7 7-1-1 Calle Principal Parking Garage
7-1-1
438 Calle Principal
Monterey, CA
93940
Calle Principal
Parking Garage
Elm st.
Magnolia Ave.
1423 5
6 Restrooms
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3843, Packet Page 4048 Exterior - On-Site
8 8-0-1 Parking Lot #8
8-0-1
Franklin/Pierce
Monterey, CA
93940
Calle Principal
Parking Garage
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3844, Packet Page 4049 Exterior - On-Site
10 10-0-1 Parking Lot 10
10-0-1
Calle P./
Franklin/Jefferson
Parking Lot 10
Elm st.
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3845, Packet Page 4050 Exterior - On-Site
11 11-0-1 Parking Lot 11
11-0-1
Calle Principal/
Pearl
Monterey, CA
Parking Lot 11
Elm st.
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3846, Packet Page 4051 Exterior - On-Site
12 12-0-1 Parking Lot C
12-0-1
700 Pacific St.
Monterey, CA
93940
Parking Lot C
Elm st.
Magnolia Ave.
12 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3847, Packet Page 4052 Exterior - On-Site
13 13-0-1 Parking Lot CR7
13-0-1
Foam/Irving
Parking Lot CR1
Elm st.
Magnolia Ave. 1 3
2 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3848, Packet Page 4053 Exterior - On-Site
14 14-0-1 Parking Lot 14
14-0-1
Bonifacio/Adams
Parking Lot 14
Elm st.
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3849, Packet Page 4054 Exterior - On-Site
17 17-0-1
Breakwater Lot
17-0-1
Coast Guard Pier
Monterey, CA
Breakwater Lot
57896
2431
10 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3850, Packet Page 4055 Exterior - On-Site
18 18-0-1 Parking Lot 18
18-0-1
Van Buren/
Jefferson
Parking Lot 18
Elm st.
Magnolia Ave.
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3851, Packet Page 4056 Exterior - On-Site
21 21-0-1 Parking Lot 21
21-0-1
Foam/
Cannery Row
Parking Lot 21
Elm st.
Magnolia Ave.
12 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3852, Packet Page 4057 Exterior - On-Site
23 23-0-1 Depot Lot (East)
23-0-1
Near Train
Depot Building
Depot Lot
(East)
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3853, Packet Page 4058 Exterior - On-Site
21 24-0-1 Parking Lot 24
24-0-1
Foam/
Cannery Row
Parking Lot 24
Elm st.
Magnolia Ave.
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3854, Packet Page 4059 Exterior - On-Site
27 27-0-1 Depot Lot (West)
27-0-1
Near Train
Depot Building
Depot Lot
(West)
1 2
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3855, Packet Page 4060 Interior - Ground Floor
29 29-1-1 Cannery Row Parking Garage
601 Wave St.
Monterey, CA
93940
Cannery Row
Parking Garage
29-1-1
10 9
12 11 5 8 7 6 1 2 4 3
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3856, Packet Page 4061 Interior - Second Floor
29 29-1-2 Cannery Row Parking Garage
601 Wave St.
Monterey, CA
93940
Cannery Row
Parking Garage
29-1-2
2 1
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3857, Packet Page 4062 Interior - Third Floor
29 29-1-3 Cannery Row Parking Garage
601 Wave St.
Monterey, CA
93940
Cannery Row
Parking Garage
29-1-3
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3858, Packet Page 4063 Interior - Fourth Floor
29 29-1-4 Cannery Row Parking Garage
601 Wave St.
Monterey, CA
93940
Cannery Row
Parking Garage
29-1-4
1 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
12/26/2011
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3859, Packet Page 4064 Interior - All Floors
30 30-1-2 East Parking Garage
340 Tyler St.
Monterey, CA
93940
East
Parking Garage
30-1-1,2,3
30-1-3
30-1-1
1 5 2 6 4 3
7 Ground Floor
1 Second and Third Floor 8
Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3860, Packet Page 4065 Interior - All Floors
31 31-1-231-1-131-1-3
West Parking Garage
340 Tyler St.
Monterey, CA
93940
West Parking
Garage
31-1-1,2,3
1 9 5 6 1 1
4 3 7 2 8 11 2 3
First Floor Second Floor Third Floor
10 Sally Swanson
Architects
San Francisco, CA
Prepared By:
Date:
04/19/2012
Sheet:
Project #:
11037
Location:Facility:
REF NORTH
N.T.S.
BARRIER
LOCATION
MAP
City of
Monterey
1 Accessible Path of TravelItem Number
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3861, Packet Page 4066 SSA Project # 11037
City of Monterey - ADA Transition Plan
March 2013
City of Monterey Facilities (Buildings)
Access Compliance Survey Reports
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3862, Packet Page 4067 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: Building Maintenance $656,335.00
Funding Source: General Fund Project: General Maintenance $656,335.00 Fac #: 101 Senior Center $37,032.00
Exterior On Site $6,292.00
Interior Lower Level $30,740.00
Fac #: 102 Corporation Yard $8,050.00
Exterior On-Site $8,050.00
Fac #: 103 Building Maintenance POM Shop $22,825.00
Exterior - POM 268 & 271 On-Site $450.00
Interior - POM 271 Ground Floor $5,820.00
Interior - POM 269 Ground Floor $1,750.00
Interior - POM 268 Ground Floor $13,180.00
Interior - POM 267 Ground Floor $1,625.00
Fac #: 104 Cannery Row Fishing Shack $4,296.00
Exterior On-Site $4,296.00
Fac #: 105 Cemetery Office $8,258.00
Exterior On-Site $8,258.00
Fac #: 108 City Hall Complex $88,287.00
Exterior On-Site $24,289.00
Interior-City Offices Ground Floor $33,865.00
Interior-Old Monterey Ground Floor $30,133.00
Fac #: 109 Conference Center $168,216.00
Exterior On Site $44,610.00
Interior Ground Floor $123,606.00
Fac #: 110 Construction Management $4,378.00
Exterior On-Site $488.00
Interior Ground Floor $3,890.00
Fac #: 111 Doc's Lab $1,330.00
Exterior On-Site $1,330.00
Fac #: 112 Employee Lounge $2,905.00
Exterior On-Site $1,035.00
Interior Ground Floor $1,870.00
Fac #: 113 Police and Fire Annex $10,143.00
Exterior On-Site $6,298.00
Police Admin. & E.O.C. Ground Floor $3,590.00
Fire Administration Ground Floor $255.00
Fac #: 114 Fire Station No. 1 $7,570.00
Interior Ground Floor $7,570.00
Fac #: 115 Fire Station No. 2 $1,065.00
Exterior On-Site $135.00
Interior Ground Floor $930.00
Fac #: 116 Fire Station No. 3 $1,840.00
Interior Ground Floor $1,840.00
Fac #: 117 Gordon House $11,016.00
Exterior On-Site $1,725.00
Interior Ground Floor $9,291.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 1 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3863, Packet Page 4068 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Fac #: 119 Harbor Patrol/PD $250.00
Exterior On-Site $250.00
Fac #: 120 Housing and Property Management $7,614.00
Exterior On-Site $5,209.00
Interior Ground Floor $2,405.00
Fac #: 123 Ketcham House $6,970.00
Exterior On-Site $2,550.00
Interior On-Site $4,420.00
Fac #: 124 Library $55,294.00
Exterior On-Site $12,503.00
Interior Basement $42,791.00
Fac #: 125 Maritime Museum Community Room and Public $5,815.00 Exterior On-Site $3,270.00
Interior Ground Floor $2,545.00
Fac #: 129 Osio Rodriquez Adobe $5,530.00
Exterior On-Site $5,530.00
Fac #: 134 Vasquez Adobe Building $13,789.00
Interior Ground Floor $13,789.00
Fac #: 136 Monterey Sports Center $38,023.00
Exterior On-Site $3,840.00
Interior Ground Floor $34,183.00
Fac #: 139 City Offices $8,640.00
Exterior On Site $200.00
Interior On Site $8,440.00
Fac #: 140 Monterey Youth Center $7,920.00
Exterior On-Site $1,125.00
Interior Ground Floor $6,795.00
Fac #: 141 Visitor Center $9,505.00
Exterior On-Site $4,130.00
Interior Ground Floor $5,375.00
Fac #: 143 Cannery Row Parking Garage Office $44,114.00 Interior Ground Floor $44,114.00
Fac #: 144 Casanova/Oak Knoll Center $14,035.00
Interior Ground Floor $14,035.00
Fac #: 145 Hilltop Center $58,510.00
Interior Ground Floor $58,510.00
Fac #: 147 Traffic Engineering $3,115.00
Exterior On-Site $1,315.00
Interior Ground Floor $1,800.00
Funding: Building Maintenance $656,335.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 2 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3864, Packet Page 4069 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: CIP - General Fund $3,303,134.00
Funding Source: Gas Tax Project: Upgrade City Pavement Management Program $23,135.00 Fac #: 101 Senior Center $2,240.00
Exterior On Site $2,240.00
Fac #: 108 City Hall Complex $2,975.00
Exterior On-Site $2,975.00
Fac #: 113 Police and Fire Annex $3,840.00
Exterior On-Site $3,840.00
Fac #: 115 Fire Station No. 2 $9,600.00
Exterior On-Site $9,600.00
Fac #: 120 Housing and Property Management $1,920.00
Exterior On-Site $1,920.00
Fac #: 139 City Offices $2,560.00
Exterior On Site $2,560.00
Funding Source: General Fund Project: City ADA Transition Plan Upgrade $2,162,075.00 Fac #: 101 Senior Center $108,458.00
Exterior On Site $35,273.00
Interior Lower Level $73,185.00
Fac #: 102 Corporation Yard $4,134.00
Exterior On-Site $4,134.00
Fac #: 103 Building Maintenance POM Shop $188,062.00
Exterior - POM 268 & 271 On-Site $10,350.00
Interior - POM 271 Ground Floor $60,800.00
Interior - POM 269 Ground Floor $37,662.00
Interior - POM 268 Ground Floor $30,130.00
Interior - POM 267 Ground Floor $49,120.00
Fac #: 104 Cannery Row Fishing Shack $610.00
Exterior On-Site $610.00
Fac #: 105 Cemetery Office $35,113.00
Exterior On-Site $35,113.00
Fac #: 108 City Hall Complex $508,371.00
Exterior On-Site $157,276.00
Interior-City Offices Ground Floor $207,355.00
Interior-Old Monterey Ground Floor $143,740.00
Fac #: 110 Construction Management $7,740.00
Exterior On-Site $3,100.00
Interior Ground Floor $4,640.00
Fac #: 111 Doc's Lab $3,200.00
Exterior On-Site $3,200.00
Fac #: 112 Employee Lounge $19,829.00
Exterior On-Site $17,829.00
Interior Ground Floor $2,000.00
Fac #: 113 Police and Fire Annex $122,804.00
Exterior On-Site $103,489.00
Police Admin. & E.O.C. Ground Floor $19,265.00
Fire Administration Ground Floor $50.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 3 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3865, Packet Page 4070 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Fac #: 114 Fire Station No. 1 $16,070.00
Interior Ground Floor $16,070.00
Fac #: 115 Fire Station No. 2 $39,500.00
Exterior On-Site $5,200.00
Interior Ground Floor $34,300.00
Fac #: 116 Fire Station No. 3 $39,200.00
Interior Ground Floor $39,200.00
Fac #: 117 Gordon House $64,865.00
Exterior On-Site $7,765.00
Interior Ground Floor $57,100.00
Fac #: 119 Harbor Patrol/PD $400.00
Exterior On-Site $400.00
Fac #: 120 Housing and Property Management $28,445.00
Exterior On-Site $21,400.00
Interior Ground Floor $7,045.00
Fac #: 123 Ketcham House $6,585.00
Exterior On-Site $1,960.00
Interior On-Site $4,625.00
Fac #: 125 Maritime Museum Community Room and Public $41,400.00 Exterior On-Site $24,775.00
Interior Ground Floor $16,625.00
Fac #: 129 Osio Rodriquez Adobe $1,600.00
Exterior On-Site $1,600.00
Fac #: 134 Vasquez Adobe Building $268,065.00
Interior Ground Floor $268,065.00
Fac #: 136 Monterey Sports Center $181,007.00
Exterior On-Site $45,694.00
Interior Ground Floor $135,313.00
Fac #: 139 City Offices $113,553.00
Exterior On Site $10,743.00
Interior On Site $102,810.00
Fac #: 140 Monterey Youth Center $117,968.00
Exterior On-Site $68,978.00
Interior Ground Floor $48,990.00
Fac #: 141 Visitor Center $33,346.00
Exterior On-Site $27,166.00
Interior Ground Floor $6,180.00
Fac #: 143 Cannery Row Parking Garage Office $29,575.00 Interior Ground Floor $29,575.00
Fac #: 144 Casanova/Oak Knoll Center $22,075.00
Interior Ground Floor $22,075.00
Fac #: 145 Hilltop Center $43,700.00
Interior Ground Floor $43,700.00
Fac #: 147 Traffic Engineering $116,400.00
Exterior On-Site $20,000.00
Interior Ground Floor $96,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 4 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3866, Packet Page 4071 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding Source: General Fund Project: Conference Center ADA Compliance Upgrades $273,953.00 Fac #: 109 Conference Center $273,953.00
Exterior On Site $38,718.00
Interior Ground Floor $235,235.00
Funding Source: General Fund Project: Library ADA Compliance Upgrades $232,196.00 Fac #: 124 Library $232,196.00
Exterior On-Site $6,440.00
Interior Basement $225,756.00
Funding Source: General Fund Project: Sports Center ADA Compliance Upgrades $35,635.00 Fac #: 136 Monterey Sports Center $35,635.00
Exterior On-Site $1,260.00
Interior Ground Floor $34,375.00
Funding Source: Marina Fund Project: TBD $354,436.00
Fac #: 118 Harbor Master Building $354,436.00
Exterior On-Site $60,368.00
Interior Ground Floor $294,068.00
Funding Source: POM - Presidio of Monterey Project: Street and Parking Lot Resurfacing $724.00 Fac #: 128 Lower Presidio Museum $724.00
Exterior On-Site $724.00
Funding Source: POM - Presidio of Monterey Project: TBD $53,937.00 Fac #: 128 Lower Presidio Museum $53,937.00
Exterior On-Site $51,802.00
Interior Ground Floor $2,135.00
Funding Source: Wharves 1 & 2 Fund Project: TBD $149,627.00 Fac #: 137 Wharf I $12,020.00
Exterior On-Site $5,000.00
Interior Ground Floor $7,020.00
Fac #: 138 Wharf II $137,607.00
Exterior On-Site $37,610.00
Beach Restroom Ground Floor $75,366.00
End Restroom Ground Floor $5,085.00
Boater's Restroom Ground Floor $19,546.00
Funding Source: Wharves 1 & 2 Fund Project: Wharf 1 Guest Dock Grant Match $17,416.00 Fac #: 137 Wharf I $17,416.00
Exterior On-Site $17,416.00
Funding: CIP - General Fund $3,303,134.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 5 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3867, Packet Page 4072 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: NIP - Neighbor Improvement Plan $10,000.00
Funding Source: Partial/Other Funded Project: Library Alarm System (CW-63) Fac #: 124 Library
Interior Ground Floor
Funding Source: Partial/Other Funded Project: Library Drinking Fountain Upgrade (CW-59) $10,000.00 Fac #: 124 Library $10,000.00
Interior Ground Floor $10,000.00
Funding: NIP - Neighbor Improvement Plan $10,000.00
Grand Total for City of Monterey $3,969,469.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 6 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3868, Packet Page 4073 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: Building Maintenance $656,335.00
General Fund $656,335.00
General Maintenance $656,335.00
Funding: CIP - General Fund $3,303,134.00
Gas Tax $23,135.00
Upgrade City Pavement Management Program $23,135.00
General Fund $2,703,859.00
City ADA Transition Plan Upgrade $2,162,075.00
Conference Center ADA Compliance Upgrades $273,953.00
Library ADA Compliance Upgrades $232,196.00
Sports Center ADA Compliance Upgrades $35,635.00
Marina Fund $354,436.00
TBD $354,436.00
POM - Presidio of Monterey $54,661.00
Street and Parking Lot Resurfacing $724.00
TBD $53,937.00
Wharves 1 & 2 Fund $167,043.00
TBD $149,627.00
Wharf 1 Guest Dock Grant Match $17,416.00
Funding: NIP - Neighbor Improvement Plan $10,000.00
Partial/Other Funded $10,000.00
Library Alarm System (CW-63)
Library Drinking Fountain Upgrade (CW-59) $10,000.00
Grand Total for City of Monterey $3,969,469.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 1 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3869, Packet Page 4074 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-0-1
Senior Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
1 Accessible Parking Space in Scholze Center Lot
Identification
Project Year:
Funding source:
Project:
502.6
PCODE EA04B 1 JOB $315 $315
Sign for accessible parking space is missing or noncompliant.
Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
5412
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:
Funding source:
Project:
208.2; 502.1
REF
5' wide access aisle
PCODE EA07REF No van parking provided (one in every 8 accessible spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).
Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
• As-Built:
5413
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04GREF REF
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
5418
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
POT from Parking Lot to Acc. Entrance of Senior Center & Driveway Parking Space
2 Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).
Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
5430
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
5431
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3870, Packet Page 4075 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-0-1
Senior Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Near stair entrance: Exterior signage at inaccessible
entrances to provide direction to accessible
entrances is missing or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
5420
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
4 POT from Main Entrance to Scholze Park
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 2 JOB $170 $340
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign to entrance to lighthouse or
through facility.
• As-Built Description:
• Proposed Solution:
5439
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
5 Stairs to Staff Entrance by Parking Lot
Cross Section
Project Year:
Funding source:
Project:
505.7
REF
1.75" wide
PCODE ED03REF Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5443
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Height
Project Year:
Funding source:
Project:
505.4
16 LF $75 $1,200
33" AFF
PCODE ED02 Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5442
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
REF
10" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5441
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3871, Packet Page 4076 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-0-1
Senior Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 18 LF $9 $162
Contrasting color strip faded at all stair nosings
(required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5440
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
6 Two Steps to Parking lot from Sidewalk on Foam St.
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5445
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
8 Staff Entrance Stairs to Alliance on Aging
Cross Section
Project Year:
Funding source:
Project:
505.7
28 LF $75 $2,100
1" - 3.25" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5448
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5449
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
9 Ramp from Senior Center Exit to Rear of Park
Curb or Barrier
Project Year:
Funding source:
Project:
405.9.2
PCODE EB14REF REF
Ramp: No curb (2" minimum height) or wheel
guide (centered approx. 3" above surface of ramp)
at sides of ramp.
Provide 2" minimum curb or wheel guide.
• As-Built Description:
• Proposed Solution:
5452
TBD
ADAAG 4.8.7
CSAS 1133B.5.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3872, Packet Page 4077 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-0-1
Senior Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Top and Bottom Extension at
Ramps
Project Year:
Funding source:
Project:
505.10.1
REF
9" extensions
PCODE ED05REF Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.
Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5453
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On Site $6,292.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3873, Packet Page 4078 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-0-1
Senior Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Total Costs for Part: Exterior $6,292.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3874, Packet Page 4079 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-0
Senior Center Part: Interior Floor: Lower Level
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
1 Studio
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 2 JOB $250 $500
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
5408
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Lower Level $500.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3875, Packet Page 4080 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
1 Main Entrance and Lobby
Carpet/Doormat
Project Year:
Funding source:
Project:
302.2
PCODE ID05A 1 JOB $75 $75
At coffee station: Doormat not securely attached to
ground or floor structure.
Attach doormat to floor surface or remove doormat.
• As-Built Description:
• Proposed Solution:
5320
TBD
ADAAG 4.5.3
CSAS 1124B.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Drinking Fountain
Project Year:
Funding source:
Project:
602.2
1 JOB $1,200 $1,200
Knee space: 26.5" high
PCODE IA02A Wall- and post-mounted cantilevered units: Knee space not provided at drinking fountain (27" high,
8" deep, 30" wide from front of drinking fountain).
Unit in good condition.
Remount fountain at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5317
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5315
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Meeting Room One (Conference Room)
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
9 lbs
PCODE ID03 At exit: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5323
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
5326
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3876, Packet Page 4081 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5322
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 1 JOB $90 $90
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5321
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
3 Small Kitchen Serving Meeting Room 1
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5331
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5332
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
37" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5329
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3877, Packet Page 4082 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
5330
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
4 Staff Restroom (by front desk)
Accessories
Project Year:
Funding source:
Project:
1 JOB $100 $100
SD: 54"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5342
TBD CSAS 1115B.8.3
Severity 2
Priority 5
General Fund
General Maintenance
Project Year:
Funding source:
Project:
603.3
1 JOB $150 $150
53" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.
Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
5341
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5336
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5337
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3878, Packet Page 4083 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Toilet Stall
Project Year:
Funding source:
Project:
604.8.1.1
1 JOB $90 $90
59" wide
PCODE WB06 Toilet stall less than 60" wide.
Interim solution: Provide directional sign to
accessible restroom.
• As-Built Description:
• Proposed Solution:
• As-Built:
5338
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
5 Staff Area by Main Lobby
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5345
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
6 Ramp To Activity Rooms
Cross Section
Project Year:
Funding source:
Project:
505.7
PCODE ED03REF REF
Standard handrail: Gripping section narrower than
1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
5347
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:
Funding source:
Project:
505.4
46 LF $75 $3,450
33.5" AFF
PCODE ED02 Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5346
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
7 Ramp To Alliance on Aging
Cross Section
Project Year:
Funding source:
Project:
505.7
60 LF $75 $4,500
5.5" x 1.5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5349
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3879, Packet Page 4084 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Curb or Barrier
Project Year:
Funding source:
Project:
405.9.2
PCODE EB14 20 LF $17 $340
Along guardrail: No curb (2" minimum height) or
wheel guide (centered approx. 3" above surface of
ramp) at sides of ramp.
Provide 2" minimum curb or wheel guide. Also
provide hand rail and guide to protect people from
running into protruding corner.
• As-Built Description:
• Proposed Solution:
5350
TBD
ADAAG 4.8.7
CSAS 1133B.5.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 16"
PCODE ID23C Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60".
Provide power door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5348
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
8 Alliance on Aging
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 3 JOB $400 $1,200 At facility main office, lobby, and kitchen: a fire alarm system, visual signal (strobe) not provided at
required type of common use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5359
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 6 JOB $250 $1,500 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
5352
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 6 LF $95 $570
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5355
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3880, Packet Page 4085 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Height
Project Year:
Funding source:
Project:
505.4
6 LF $75 $450
32" AFF
PCODE ED02 Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5357
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5356
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
9 Restroom Lobby
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5362
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
10 Women's Restroom
Accessories
Project Year:
Funding source:
Project:
3 JOB $100 $300
EHD: 47"
SD: 44"
PTD: 41"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5367
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3881, Packet Page 4086 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Project Year:
Funding source:
Project:
603.3
1 JOB $150 $150
41.5" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.
Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
5368
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
64" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5369
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5365
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5364
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.
CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
5363
TBD CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
General Maintenance
11 Men's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3882, Packet Page 4087 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Accessories
Project Year:
Funding source:
Project:
3 JOB $100 $300
PTD: 41" AFF
SD: 44" AFF
EHD: 45" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5378
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
65" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5383
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5376
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5375
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Grab Bars
Project Year:
Funding source:
Project:
609.3
1 JOB $500 $500
2.5" to wall
PCODE WB07ENT Grab bar clearance not 1-1/2" from wall.
Provide additional partition.
• As-Built Description:
• Proposed Solution:
• As-Built:
5385
TBD
ADAAG 4.26.2
CSAS 1115B.7.1
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3883, Packet Page 4088 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.
CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
5373
TBD CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
General Maintenance
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07REF REF
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5374
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5382
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
12 Corridor to Dance Room
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10C 1 JOB $90 $90
At door leading into exit ramp: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT RAMP
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5387
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
13 Meeting Room Three
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3884, Packet Page 4089 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
3 JOB $25 $75
7 - 13 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5391
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 2 JOB $25 $50
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5393
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5389
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 1 JOB $90 $90
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5390
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
14 Meeting Room Three Kitchen
Sink
Project Year:
Funding source:
Project:
606.3
PCODE IN06 1 JOB $1,750 $1,750 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
5395
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3885, Packet Page 4090 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
5396
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
15 Computer Room
Door Closer
Project Year:
Funding source:
Project:
404.2.9
3 JOB $25 $75
8 - 12 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5404
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 2 JOB $25 $50
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5401
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 2 JOB $90 $180
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5400
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
16 Meeting Room Four and Kitchen
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
9 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5406
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3886, Packet Page 4091 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Sink
Project Year:
Funding source:
Project:
606.2
2 JOB $1,750 $3,500
Knee space: 24" high
PCODE IN06A Sink does not have knee space min. 27" high x 19" deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
• As-Built:
5405
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $30,240.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3887, Packet Page 4092 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
101-1-1
Senior Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 280 Dickman Ave Building Maintenance
Total Costs for Part: Interior $30,740.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3888, Packet Page 4093 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
102-0-1
Corporation Yard Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 21- 27 Ryan Ranch Building Maintenance
2 Park's Department (Staff Only)
Door
Project Year:
Funding source:
Project:
404.2.4
REF
7.7%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).
Provide sign directing persons to front entrance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5901
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 11 JOB $250 $2,750 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
5898
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Threshold
Project Year:
Funding source:
Project:
404.2.5
REF
4"
PCODE ID02AREF Door inaccessible due to threshold or step at door exceeding 3/4".
Provide sign directing persons to front entrance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5900
TBD
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
Minimum Number
Project Year:
Funding source:
Project:
208.2
PCODE EA01ANT 1 JOB $300 $300
Guest Parking: At parking lot with 1-25 spaces, the
number of accessible spaces is less than required by
code; 1 space required
Provide required accessible parking space with sign
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
5897
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 12 JOB $50 $600
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5899
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3889, Packet Page 4094 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
102-0-1
Corporation Yard Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 21- 27 Ryan Ranch Building Maintenance
3 Fleet Services (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 3 JOB $250 $750
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
5904
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
4 Street Services (Staff Only)
Door
Project Year:
Funding source:
Project:
404.2.4
REF
7.9%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).
Provide sign directing persons to main entrance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5906
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 11 JOB $250 $2,750 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
5905
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
5 Staff Parking
Minimum Number
Project Year:
Funding source:
Project:
208.2
3 JOB $300 $900
0 accessible spaces provided
PCODE EA01C At parking lot with 51-75 spaces, the number of accessible spaces is less than required by code; 3
spaces required.
Provide required accessible parking spaces with
signs including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
• As-Built:
5909
TBD
ADAAG 4.1.2(5)*
CSAS Tbl. 11B-6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $8,050.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3890, Packet Page 4095 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
102-0-1
Corporation Yard Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 21- 27 Ryan Ranch Building Maintenance
Total Costs for Part: Exterior $8,050.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3891, Packet Page 4096 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-0-1
Building Maintenance POM Shop Part: Exterior - POM 268 & 271 Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
1 Accessible Parking Serving Building Maintenance
Parking
Project Year:
Funding source:
Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).
Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
6763
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
6765
TBD CSAS 1129B.4
Severity 4
Priority 1
General Fund
General Maintenance
Total Costs for Floor: On-Site $450.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3892, Packet Page 4097 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-0-1
Building Maintenance POM Shop Part: Exterior - POM 268 & 271 Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Total Costs for Part: Exterior - POM 268 & 271 $450.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3893, Packet Page 4098 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-1-1
Building Maintenance POM Shop Part: Interior - POM 271 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
1 Main Entrance Stairs
Cross Section
Project Year:
Funding source:
Project:
505.7
7 LF $75 $525
3.25" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6664
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6660
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 7 LF $95 $665
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6662
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
6665
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Conference Room
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3894, Packet Page 4099 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-1-1
Building Maintenance POM Shop Part: Interior - POM 271 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6666
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
6668
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
6669
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.4
PCODE IN07 1 JOB $600 $600
Sink faucet controls not accessible.
Provide accessible sink faucet controls.
• As-Built Description:
• Proposed Solution:
6670
TBD
ADAAG 4.24.7
CSAS 1115B.4.7.1
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
3 Stairs to Restroom and Restroom
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 3 JOB $250 $750
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6675
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3895, Packet Page 4100 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-1-1
Building Maintenance POM Shop Part: Interior - POM 271 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 12 LF $95 $1,140 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6671
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $5,820.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3896, Packet Page 4101 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-1-1
Building Maintenance POM Shop Part: Interior - POM 271 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Total Costs for Part: Interior - POM 271 $5,820.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3897, Packet Page 4102 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-2-1
Building Maintenance POM Shop Part: Interior - POM 269 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
1 Entrance to Workshops & Workshops in General
Sink
Project Year:
Funding source:
Project:
606.3
PCODE IN06 1 JOB $1,750 $1,750 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
6680
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $1,750.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3898, Packet Page 4103 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-2-1
Building Maintenance POM Shop Part: Interior - POM 269 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Total Costs for Part: Interior - POM 269 $1,750.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3899, Packet Page 4104 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
1 Accessible Entrance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6683
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 2 JOB $230 $460
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide directional signage sufficient to guide
persons to accessible entrances and provide ISA
sign at accessible entrance.
• As-Built Description:
• Proposed Solution:
6682
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
6681
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Staff Break Room
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door at small office does not have accessible
operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6698
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3900, Packet Page 4105 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6694
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
6696
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 1 JOB $90 $90
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
6695
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
35.25" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
6688
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
6687
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
3 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3901, Packet Page 4106 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Accessories
Project Year:
Funding source:
Project:
308.2.1
2 JOB $100 $200
SCD: 54" AFF
PTD: 52" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6709
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
603.3
1 JOB $150 $150
53" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.
Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
6710
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6701
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
PCODE ID24NT 1 JOB $500 $500
Front approach: At push side, door does not have
clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).
Change door swing out.
• As-Built Description:
• Proposed Solution:
6702
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:
Funding source:
Project:
606.4
PCODE WD06REF REF
Lavatory: Accessible faucet (lever-operated, pushtype or electronically controlled) not provided at otherwise accessible lavatory.
Provide accessible faucet at accessible lavatory.
• As-Built Description:
• Proposed Solution:
6706
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3902, Packet Page 4107 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6699
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6700
TBD CSAS 1115B.6
Severity 3
Priority 4
General Fund
General Maintenance
4 Men's Restroom
Accessories
Project Year:
Funding source:
Project:
2 JOB $75 $150
SD: 54" AFF
PTD: 53" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).
Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
6716
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 4
General Fund
General Maintenance
Project Year:
Funding source:
Project:
603.3
1 JOB $150 $150
53" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.
Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
6715
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3903, Packet Page 4108 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6712
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6711
TBD CSAS 1115B.6
Severity 3
Priority 4
General Fund
General Maintenance
5 Corridor to Locker Room
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 2 JOB $250 $500
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6718
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
44" to wall
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing in and relocate lockers.
• As-Built Description:
• Proposed Solution:
• As-Built:
6719
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
6 File Storage Room
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3904, Packet Page 4109 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6722
TBD
CSAS 1133B.2.6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
Door width + 7"
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Remodel area or remove door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6723
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
7 Entrance Stairs at Staff Break Room
Cross Section
Project Year:
Funding source:
Project:
505.7
16 LF $75 $1,200
3.5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6730
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6725
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6726
TBD
CSAS 1133B.2.6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3905, Packet Page 4110 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 16 LF $95 $1,520 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6729
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
6727
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
6731
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
8 Building Main Entrance and Lobby
Cross Section
Project Year:
Funding source:
Project:
505.7
8 LF $75 $600
3.5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6734
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6739
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3906, Packet Page 4111 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6735
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door to superintendent's office does not have
accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6741
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6738
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 16 LF $95 $1,520 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6733
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
6732
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3907, Packet Page 4112 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
6740
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
6742
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
9 Corridor to Break Room
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 2 JOB $250 $500
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6743
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 2 JOB $50 $100
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
6744
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $13,180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3908, Packet Page 4113 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-3-1
Building Maintenance POM Shop Part: Interior - POM 268 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Total Costs for Part: Interior - POM 268 $13,180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3909, Packet Page 4114 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-4-1
Building Maintenance POM Shop Part: Interior - POM 267 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
1 Entrance to Offices / Lobby
Accessible Route
Project Year:
Funding source:
Project:
REF
24" drop off to drain
PCODE EG08REF (CA requirement only) Abrupt changes in level, except between a walk or sidewalk and an adjacent
street or driveway, exceeding 4" in depth must be
identified by a 6" min. curb above the potential
drop off.
Provide a 6" curb as a warning curb for the blind or
a handrail centered +/- 3" above finished surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6748
TBD CSAS 1133B.8.1
Severity 1
Priority 1
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
11 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6752
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6746
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6754
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Lower Coffee, Restroom & Office Area
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3910, Packet Page 4115 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-4-1
Building Maintenance POM Shop Part: Interior - POM 267 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 3 JOB $250 $750
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6758
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $1,625.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3911, Packet Page 4116 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
103-4-1
Building Maintenance POM Shop Part: Interior - POM 267 Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey Building Maintenance
Total Costs for Part: Interior - POM 267 $1,625.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3912, Packet Page 4117 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
104-0-1
Cannery Row Fishing Shack Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row Building Maintenance
1 POT from Cannery Row to Lower Fishing Shack
Cross Section
Project Year:
Funding source:
Project:
505.7
28 LF $75 $2,100
1.75" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5980
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Ramps
Project Year:
Funding source:
Project:
303.4
PCODE EB01ANT 1 JOB $150 $150
Ramp needed to provide disabled access at steps or
change of level along path of travel.
Provide sign to direct persons to bike path.
• As-Built Description:
• Proposed Solution:
5977
TBD
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 70 LF $9 $630
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5979
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
2 Stairs to Upper Fish Shack
Cross Section
Project Year:
Funding source:
Project:
505.7
16 LF $75 $1,200
1.75" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5985
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:
Funding source:
Project:
505.4
PCODE ED02REF REF
Handrail gripping surface top not mounted between
34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
5986
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3913, Packet Page 4118 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
104-0-1
Cannery Row Fishing Shack Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row Building Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 24 LF $9 $216
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5984
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $4,296.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3914, Packet Page 4119 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
104-0-1
Cannery Row Fishing Shack Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row Building Maintenance
Total Costs for Part: Exterior $4,296.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3915, Packet Page 4120 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
105-0-1
Cemetery Office Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont and Camino Aguajito Building Maintenance 1 Cemetery Office Parking
Minimum Number
Project Year:
Funding source:
Project:
208.2
PCODE EA01A 1 JOB $300 $300
At parking lot with 1-25 spaces, the number of
accessible spaces is less than required by code; 1
space required
Provide required accessible parking space with sign
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
5936
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 POT to Cemetery Office and Restrooms
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 12 LF $95 $1,140 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5942
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 12 LF $9 $108
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5941
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
3 Cemetery Office
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5945
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06A 1 JOB $1,750 $1,750 Sink does not have knee space min. 27" high x 19" deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
5946
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
4 Left Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3916, Packet Page 4121 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
105-0-1
Cemetery Office Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont and Camino Aguajito Building Maintenance Accessories
Project Year:
Funding source:
Project:
1 JOB $100 $100
SD: 42" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5952
TBD CSAS 1115B.8.3
Severity 4
Priority 5
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5951
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07REF REF
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5950
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5949
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3917, Packet Page 4122 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
105-0-1
Cemetery Office Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont and Camino Aguajito Building Maintenance Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5948
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
5 Right Restroom
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5961
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07REF REF
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5960
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5959
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3918, Packet Page 4123 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
105-0-1
Cemetery Office Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont and Camino Aguajito Building Maintenance Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5958
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
6 Ramp Serving Mausoleum
Curb or Barrier
Project Year:
Funding source:
Project:
405.9.2
PCODE EB14REF REF
Ramp: No curb (2" minimum height) or wheel
guide (centered approx. 3" above surface of ramp)
at sides of ramp.
Provide 2" minimum curb or wheel guide.
• As-Built Description:
• Proposed Solution:
5967
TBD
ADAAG 4.8.7
CSAS 1133B.5.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
7 Southeast POT to Mausoleum
Cross Section
Project Year:
Funding source:
Project:
505.7
36 LF $75 $2,700
2" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5975
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend 12" minimum
horizontally beyond the bottom nosing.
Extend stair handrail at bottom (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
5976
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $8,258.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3919, Packet Page 4124 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
105-0-1
Cemetery Office Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont and Camino Aguajito Building Maintenance Total Costs for Part: Exterior $8,258.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3920, Packet Page 4125 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
1 Accessible Parking Spaces Serving City Hall Complex (2 Spaces) Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04G 2 JOB $100 $200
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
2383
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
2 POT from Acc. Parking to West City Hall Entrance
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs(steps between Jail
and City Hall), required on both sides (not required
at curb ramps or adjacent to seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2393
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
7 Main Stairway to City Hall Offices/Council Chamber
Accessible Route
Project Year:
Funding source:
Project:
45 LF $45 $2,025
22"
PCODE EG08 (CA requirement only) Abrupt changes in level, except between a walk or sidewalk and an adjacent
street or driveway, exceeding 4" in depth must be
identified by a 6" min. curb above the potential
drop off.
Provide a 6" curb as a warning curb for the blind or
a handrail centered +/- 3" above finished surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
2415
TBD CSAS 1133B.8.1
Severity 1
Priority 5
General Fund
General Maintenance
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at one side of stairs to lower
patio plaza, required on both sides (not required at
curb ramps or adjacent to seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2411
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3921, Packet Page 4126 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06 3 JOB $170 $510
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing. Handrail is obstructed by column.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
2412
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
POT from South City Hall Entrance to South Entrance to City Managers Offices (PRoW)
8 Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2420
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
POT from Sidewalk along East Side of City Managers Office to Main City Hall Walkway
9 Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02 4 LF $9 $36
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2422
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
12 Path of Travel from City Manager Offices to Non-accessible Restroom Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign to accessible restroom.
• As-Built Description:
• Proposed Solution:
2433
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
Walk
Project Year:
Funding source:
Project:
405.1
REF
4.3% - 5.7%
PCODE EF01AREF Walk near door landing: Slope greater than 1:20 (5.0%), and walk does not comply with
requirements for ramps.
Provide directional sign to accessible restroom.
• As-Built Description:
• Proposed Solution:
• As-Built:
2434
TBD
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3922, Packet Page 4127 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Project Year:
Funding source:
Project:
405.1
REF
7.6%
PCODE EF01AREF Walk near door landing: Slope greater than 1:20 (5.0%), and walk does not comply with
requirements for ramps.
Provide directional sign to accessible restroom.
• As-Built Description:
• Proposed Solution:
• As-Built:
2435
TBD
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
13 Site Entry to Colton Hall Museum from King St.
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 16 LF $95 $1,520 Handrail not provided at stairs, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2437
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2436
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
14 Main Walkway from Pacific St. to Front of Colton Hall Route Sign
Project Year:
Funding source:
Project:
PCODE SA20NT 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign to accessible entrance.
• As-Built Description:
• Proposed Solution:
2439
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
17 Northeast Stairs at Friendly Plaza
Handrail
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06 1 JOB $170 $170
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
2451
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3923, Packet Page 4128 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2453
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02 42 LF $9 $378
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2449
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
18 Northwest Stairs at Friendly Plaza
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 48 LF $95 $4,560 Handrail not provided at stairs, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2457
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
8 JOB $170 $1,360
8" - 9" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2456
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2452
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3924, Packet Page 4129 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02 45 LF $9 $405
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2454
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
19 Southwest Stairs at Friendly Plaza
Handrail
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
12 JOB $170 $2,040
0" - 9" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2459
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2458
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02 65 LF $9 $585
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2460
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
20 Southeast Stairs at Friendly Plaza
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 12 LF $95 $1,140 Handrail not provided at stairs, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2463
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3925, Packet Page 4130 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2462
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
21 Steps Between Old Monterey Jail and Council Chamber
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs, required on both
sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2465
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
504.6
PCODE ED01 12 LF $95 $1,140 Handrail not provided at stairs, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2467
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
22 Path from Accessible Parking to Old Monterey Jail
Handrail
Project Year:
Funding source:
Project:
504.6
48 REF
16.2% - 18.7%
PCODE ED01REF Handrail not provided at lower ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
• As-Built:
2471
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
23 Path from Accessible Parking to City Planning Offices Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs, required on both
sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2475
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3926, Packet Page 4131 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
2 JOB $170 $340
9" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2476
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
24 Path of Travel from Friendly Plaza to Colton Hall
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 12 LF $95 $1,140 Handrail not provided at stairs, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2480
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02 15 LF $9 $135
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2481
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
25 Stairs to City Manager Offices (Room 1)
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 9 LF $95 $855
Handrail not provided at stairs, required on both
sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2489
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.7
18 LF $75 $1,350
2.5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2488
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3927, Packet Page 4132 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
REF
4" - 6" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2487
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02REF 25 REF
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads when altering area.
• As-Built Description:
• Proposed Solution:
2491
TBD
CSAS 1133B.4.4
Severity 2
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $24,289.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3928, Packet Page 4133 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-0-1
City Hall Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Total Costs for Part: Exterior $24,289.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3929, Packet Page 4134 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
1 City Manager / Mayor Office (Room 1)
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2495
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 2 JOB $250 $500
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2498
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
2492
TBD CSAS 1133B.2.6
Severity 3
Priority 4
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
PCODE ID23ANT 1 JOB $50 $50
Front approach: At pull side, door does not have
clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Remove door closer and swing door out.
• As-Built Description:
• Proposed Solution:
2494
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
2502
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3930, Packet Page 4135 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
2 Conference Room / Lord Nelson Room (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 2 JOB $250 $500
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2503
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
2508
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
3 City Manager Office (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2510
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
4 Mayor Office (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2515
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
5 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3931, Packet Page 4136 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Directional Sign
Project Year:
Funding source:
Project:
PCODE SA19 1 JOB $90 $90
No sign at non-accessible room or space directing
persons to an accessible room that provides the
same or equivalent service.
Provide directional sign to accessible restroom.
• As-Built Description:
• Proposed Solution:
2517
TBD
ADAAG 35.163(b); 4.1.6(3)(e)(iii)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3 General Fund
General Maintenance
Door
Project Year:
Funding source:
Project:
PCODE ID06AREF REF
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
2519
TBD CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
13 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2527
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
2525
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
2526
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3932, Packet Page 4137 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05CREF REF
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
2522
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
6 Men's Restroom
Directional Sign
Project Year:
Funding source:
Project:
PCODE SA19 1 JOB $90 $90
No sign at non-accessible room or space directing
persons to an accessible room that provides the
same or equivalent service.
Provide directional sign to accessible restroom..
• As-Built Description:
• Proposed Solution:
2536
TBD
ADAAG 35.163(b); 4.1.6(3)(e)(iii)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3 General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
2531
TBD CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.
CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
2530
TBD CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.8
PCODE SA11ANT 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
2529
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3933, Packet Page 4138 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
2528
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
2539
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
7 Accessible Unisex Restroom
Accessories
Project Year:
Funding source:
Project:
REF
EHD: 45"
PCODE WG01AREF Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
2549
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
Project Year:
Funding source:
Project:
603.3
REF
43" AFF
PCODE WG03REF Bottom of flat, not tilted mirror more than 40" above floor.
Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
2548
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door
Project Year:
Funding source:
Project:
PCODE ID06AREF REF
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
2542
TBD CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3934, Packet Page 4139 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
8 Permit and Inspection Service (Room 4)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2561
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Electrical
Project Year:
Funding source:
Project:
308.2.1 & 308.2.2
1 JOB $300 $300
Thermostat: 65" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.
Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2558
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
2553
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
2555
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2 General Fund
General Maintenance
9 Rear Offices (Staff Only)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3935, Packet Page 4140 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Door Clearance
Project Year:
Funding source:
Project:
404.3.1
1 JOB $2,600 $2,600
31" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).
Remove door frame to provide 32" clear opening
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
2564
TBD
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 5
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
2562
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4 General Fund
General Maintenance
10 City Clerk (Room 6)/Entrance Lobby
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2565
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Drinking Fountain
Project Year:
Funding source:
Project:
1 JOB $3,200 $3,200
2" high
PCODE IA03E Drinking fountain water flow less than 4" high; unit in poor condition.
Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
2567
TBD
ADAAG 4.15.3
CSAS 1115B.4.6.5
Severity 3
Priority 3 General Fund
General Maintenance
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 5 LF $95 $475
Handrail not provided at stairs, required on both
sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2569
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3936, Packet Page 4141 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06A 4 JOB $320 $1,280 Floor mounted stair handrail does not extend horizontally 12" minimum beyond top nosing, and
one tread width sloped, plus 12" minimum
horizontally beyond the bottom nosing.
Extend stair handrail at top and bottom (cost for
both extensions).
• As-Built Description:
• Proposed Solution:
2568
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
11 City Clerk Offices
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2572
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
2571
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
12 City Clerk Staff Offices
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 2 JOB $250 $500
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2578
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
13 Council Chamber (Designated Accessible Entrance)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3937, Packet Page 4142 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
9 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2581
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 2"
PCODE ID24C Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
2582
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
2583
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1 General Fund
General Maintenance
14 Council Chamber Main Entrance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2585
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
2584
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3938, Packet Page 4143 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Project Year:
Funding source:
Project:
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
2587
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1 General Fund
General Maintenance
15 Council Chamber Assembly Room
Assistive Listening
Project Year:
Funding source:
Project:
219.1 & 706.1
PCODE GI01A 1 JOB $1,700 $1,700 No permanently installed assistive listening system provided for smaller assembly area
(accommodating 50 to 200 persons).
Provide permanent assistive listening system (FM
type) for smaller assembly area, including sign at
entrance indicating availability to the public.
• As-Built Description:
• Proposed Solution:
2592
TBD
ADAAG 4.1.3(19)(b)
CSAS 1104B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
703.7.2.4
PCODE GI02 1 JOB $100 $100
No signs at the building or assembly area entrance
to notify patrons that an assistive listening system is available.
Provide assistive listening signage.
• As-Built Description:
• Proposed Solution:
2593
TBD
ADAAG 4.1.3(19)(b)
CSAS 1104B.2.4
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Disabled Seating
Project Year:
Funding source:
Project:
PCODE GB01E 1 JOB $150 $150
Aisle transfer seats not provided (1% of total fixed
seats, but not less than 1).
Provide aisle transfer seats without armrests on the
aisle side, or removable or folding armrests on the
aisle seat. Include sign or marker identifying such
seats. (NOTE: Space must be adjacent to regular
seating; can provide easily removable fixed seat).
• As-Built Description:
• Proposed Solution:
2588
TBD
ADAAG 4.1.3(19)(a)
CSAS 1104B.3.8
Severity 3
Priority 2 General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2595
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3939, Packet Page 4144 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Electrical
Project Year:
Funding source:
Project:
308.2.1 & 308.2.2
1 JOB $300 $300
66" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.
Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2597
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
1 JOB $300 $300
Light switches: 56" to 76" AFF
PCODE IC01 Electric switch or control, mounted less than 36" or more than 48" above floor to center.
Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2598
TBD
ADAAG 4.2.5&6
CSAS 1117B.6.3
Severity 1
Priority 2 General Fund
General Maintenance
Operable Part
Project Year:
Funding source:
Project:
PCODE IC02REF REF
Light fixture operable part(s) require tight grasping,
pinching, or twisting of the wrist with one hand.
Modify or replace the operable part(s) to not require
tight grasping, pinching, or twisting of the wrist
with one hand.
• As-Built Description:
• Proposed Solution:
2599
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 2 General Fund
General Maintenance
Operating Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07ANT 1 JOB $50 $50
Light switches cabinet cabinet does not have
accessible hardware.
Provide accessible pull / latch (touch latches or Upulls). • As-Built Description:
• Proposed Solution:
2596
TBD
ADAAG 4.25.4
CSAS 1125B.4
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
16 Kitchen / Restroom (Council Chamber)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2603
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3940, Packet Page 4145 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2610
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07A 1 JOB $100 $100
AV station does not have accessible hardware.
Provide accessible pull / latch (touch latches or Upulls). • As-Built Description:
• Proposed Solution:
2615
TBD
ADAAG 4.25.4
CSAS 1125B.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
REF
42" from face of door to wall
PCODE ID23REF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
2613
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
Top: 35.75" high
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
2607
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.3
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
2608
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
17 Council Chamber Entrance (Staff Only)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3941, Packet Page 4146 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-1
City Hall Complex Part: Interior-City Offices Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Directional Sign
Project Year:
Funding source:
Project:
PCODE SA19 1 JOB $90 $90
No sign at non-accessible room or space directing
persons to an accessible room that provides the
same or equivalent service.
Provide directional sign.
• As-Built Description:
• Proposed Solution:
2617
TBD
ADAAG 35.163(b); 4.1.6(3)(e)(iii)
CSAS 1117B.5.8.1.2
Severity 4
Priority 4 General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2616
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
18 Public Works Lobby (Room 7)
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2620
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2623
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 19"
PCODE ID23C Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 60".
Provide power door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
2622
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $27,750.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3942, Packet Page 4147 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-2
City Hall Complex Part: Interior-City Offices Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
1 Stairs to Public Works
Handrail
Project Year:
Funding source:
Project:
505.4
REF
29" AFF
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2626
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.7
56 LF $75 $4,200
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2625
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.5
REF
2.5" to wall
PCODE ED04REF Handrail: Clearance to wall is not 1-1/2".
Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2628
TBD
ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
2627
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
2 Staff Restroom
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2631
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3943, Packet Page 4148 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-2
City Hall Complex Part: Interior-City Offices Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
REF
Door width + 2" to lavatory
PCODE ID23REF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
2632
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 5
ADA-2010
General Fund
General Maintenance
3 Office Space Adjacent to Restroom
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2635
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
4 Public Works (Room 7)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2638
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
2639
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3944, Packet Page 4149 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-2
City Hall Complex Part: Interior-City Offices Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Project Year:
Funding source:
Project:
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
2641
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2 General Fund
General Maintenance
5 Staff Offices
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
15 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2646
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 4 JOB $250 $1,000 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2643
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Second Floor $6,115.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3945, Packet Page 4150 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-1-2
City Hall Complex Part: Interior-City Offices Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Total Costs for Part: Interior-City Offices $33,865.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3946, Packet Page 4151 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-1
City Hall Complex Part: Interior-Old Monterey Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
2 Colton Hall Front Porch
Handrail
Project Year:
Funding source:
Project:
505.7
14 LF $75 $1,050
6" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2650
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
2654
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
2652
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
50 LF $9 $450
1" to 1.5" unbeveled
PCODE EC02 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
• As-Built:
2649
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
3 City Planning Lobby
Alarm Signal
Project Year:
Funding source:
Project:
1 JOB $100 $100
114" AFF
PCODE IC05E Visual signal (strobe) is not between 80" and 96" above the finished floor.
Relocate visual signal at 80" to 96" above the
finished floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
2662
TBD
ADAAG 4.28.3(6)
CSAS 1114B.2.2
Severity 3
Priority 3 General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3947, Packet Page 4152 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-1
City Hall Complex Part: Interior-Old Monterey Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2656
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2655
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
2657
TBD CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
Door width + 1" to bench, 16" deep
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
2659
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
5 Rear Entrance (West)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2666
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3948, Packet Page 4153 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-1
City Hall Complex Part: Interior-Old Monterey Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 2" to wall, 16" deep
PCODE ID23C Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60".
Provide power door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
2667
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
6 Staff Entrance (Door Near Old Monterey Jail)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2669
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
REF
Door width + 0"
PCODE ID23CREF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60".
Provide power door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
2673
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
2672
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
7 Stairs to Museum
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 40 LF $95 $3,800 Handrail not provided at stairs, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2674
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3949, Packet Page 4154 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-1
City Hall Complex Part: Interior-Old Monterey Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Project Year:
Funding source:
Project:
505.7
40 LF $75 $3,000
5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2679
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Stairs
Project Year:
Funding source:
Project:
504.4
PCODE EC02 126 LF $9 $1,134 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2677
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
504.4
PCODE EC02 114 LF $9 $1,026 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2678
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
8 Museum and Culture Offices
Alarm Signal
Project Year:
Funding source:
Project:
1 JOB $100 $100
114" AFF
PCODE IC05E Visual signal (strobe) is not between 80" and 96" above the finished floor.
Relocate visual signal at 80" to 96" above the
finished floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
2685
TBD
ADAAG 4.28.3(6)
CSAS 1114B.2.2
Severity 3
Priority 3 General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2682
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3950, Packet Page 4155 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-1
City Hall Complex Part: Interior-Old Monterey Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2680
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2683
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 1", 16" deep
PCODE ID23C Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60".
Provide power door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
2681
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
9 Office Restroom (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 6 JOB $250 $1,500 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
2686
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
Handrail not provided at stairs, required on both
sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2688
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3951, Packet Page 4156 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-1
City Hall Complex Part: Interior-Old Monterey Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11ANT 2 JOB $90 $180
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
2692
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $25,385.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3952, Packet Page 4157 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-2
City Hall Complex Part: Interior-Old Monterey Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
1 Museum at 2nd Floor
Alarm Signal
Project Year:
Funding source:
Project:
1 JOB $500 $500
112" AFF
PCODE IC05A Room with audible smoke alarm does not provide visual signal (strobe).
Provide combination visual / audible signal device.
• As-Built Description:
• Proposed Solution:
• As-Built:
2694
TBD
ADAAG 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3 General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2695
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
2697
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1 General Fund
General Maintenance
2 Exit Door
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
6 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2700
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
2703
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3953, Packet Page 4158 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-2
City Hall Complex Part: Interior-Old Monterey Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Door Stopper
Project Year:
Funding source:
Project:
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
2699
TBD CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
2698
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2 General Fund
General Maintenance
3 Exit Stairs
Handrail
Project Year:
Funding source:
Project:
504.6
PCODE ED01 10 LF $95 $950
Handrail not provided at stairs, required on both
sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2704
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.7
28 LF $75 $2,100
5.5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2705
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
2706
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3954, Packet Page 4159 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-2
City Hall Complex Part: Interior-Old Monterey Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 52 LF $9 $468
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2708
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Second Floor $4,748.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3955, Packet Page 4160 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
108-2-2
City Hall Complex Part: Interior-Old Monterey Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 580 Pacific St. Building Maintenance
Total Costs for Part: Interior-Old Monterey Jail/Colton Hall $30,133.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3956, Packet Page 4161 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
2 Fountain Plaza
Accessible Route
Project Year:
Funding source:
Project:
68 LF $45 $3,060
10.5" deep
PCODE EG08 At fountain: (CA requirement only) Abrupt changes in level, except between a walk or sidewalk and an
adjacent street or driveway, exceeding 4" in depth
must be identified by a 6" min. curb above the
potential drop off.
Provide a 6" curb as a warning curb for the blind or
a handrail centered +/- 3" above finished surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5274
TBD CSAS 1133B.8.1
Severity 2
Priority 5
General Fund
General Maintenance
Cross Section
Project Year:
Funding source:
Project:
505.7
24 LF $75 $1,800
2" wide
PCODE ED03 Standard handrail on stairs: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5275
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Top stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5278
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
3 SE Stairway Exterior
Cross Section
Project Year:
Funding source:
Project:
505.7
28 LF $75 $2,100
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5280
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3957, Packet Page 4162 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5281
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 126 LF $9 $1,134 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5279
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
5 Level Two Patio East (No Wheelchair Access)
Cross Section
Project Year:
Funding source:
Project:
505.7
72 LF $75 $5,400
2" wide
PCODE ED03 Standard handrail at stairs serving conference room:
Gripping section narrower than 1-1/4" or wider than
1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5285
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5287
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 192 LF $9 $1,728 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5286
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
6 Level Three Patio
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3958, Packet Page 4163 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Cross Section
Project Year:
Funding source:
Project:
505.7
PCODE ED03 32 LF $75 $2,400 North Stairs from second level to third level standard handrail: Gripping section narrower than
1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
5288
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
North stair from level two to level three handrail
does not extend horizontally 12" minimum beyond
top nosing, and one tread width sloped, plus 12"
minimum horizontally beyond the bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5289
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 192 LF $9 $1,728 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5290
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
8 South Stairway from Level Three to Level Four
Cross Section
Project Year:
Funding source:
Project:
505.7
PCODE ED03 20 LF $75 $1,500 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
5296
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5298
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3959, Packet Page 4164 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 80 LF $9 $720
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5297
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
9 West Stairway from Level Three to Level Four
Cross Section
Project Year:
Funding source:
Project:
505.7
PCODE ED03 20 LF $75 $1,500 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
5301
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5303
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 80 LF $9 $720
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5302
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
11 Jeffers Plaza
Cross Section
Project Year:
Funding source:
Project:
505.7
90 LF $75 $6,750
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5305
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3960, Packet Page 4165 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Project Year:
Funding source:
Project:
505.7
PCODE ED03 32 LF $75 $2,400 At ramp standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
5311
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 70 LF $95 $6,650 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5306
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
504.6
PCODE ED01 32 LF $95 $3,040 At ramp: Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps
or adjacent to seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5309
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5308
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 220 LF $9 $1,980 Contrasting color strip not provided at all stair nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5307
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On Site $44,610.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3961, Packet Page 4166 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Total Costs for Part: Exterior $44,610.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3962, Packet Page 4167 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
2 Elevator
Operating Hardware
Project Year:
Funding source:
Project:
811.4
PCODE ID07ANT 1 JOB $50 $50
Emergency phone cabinet does not have accessible
hardware.
Provide accessible pull / latch (touch latches or Upulls). • As-Built Description:
• Proposed Solution:
5008
TBD
ADAAG 4.25.4
CSAS 1125B.4
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
3 Junipero Serra Room
Door
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 4 JOB $200 $800
At main entrance doors: push side of door on
accessible route, bottom 10" does not have a
smooth, uninterrupted surface (required in CA
only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5010
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 4 JOB $200 $800
At side entrance: push side of door on accessible
route, bottom 10" does not have a smooth,
uninterrupted surface (required in CA only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5016
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 2 JOB $200 $400
At connecting doors by side entrance: push side of
door on accessible route, bottom 10" does not have
a smooth, uninterrupted surface (required in CA
only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5018
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
8 JOB $25 $200
8 - 15 lbs
PCODE ID03 At main entrance doors: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5009
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3963, Packet Page 4168 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Project Year:
Funding source:
Project:
404.2.9
8 JOB $25 $200
8 - 12 lbs
PCODE ID03 At side entrance: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5013
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.9
4 JOB $25 $100
9 - 12 lbs
PCODE ID03 At connecting doors by side entrance: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5019
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 4 JOB $25 $100
At connecting doors by side entrance: push side of
door on accessible route, bottom 10" does not have
a smooth, uninterrupted surface (required in CA
only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5017
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Drinking Fountain
Project Year:
Funding source:
Project:
602.2
PCODE IA02B 1 JOB $3,200 $3,200 At restroom lobby in Serra 1: Wall- and postmounted cantilevered units: Drinking fountain less than 17"-19" deep (front to back).
Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
5020
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 4 JOB $90 $360
At main entrance doors: Where required exit signs
are installed, signs to provide exiting information
for people with vision impairment are not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5012
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3964, Packet Page 4169 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 4 JOB $90 $360
At side entrance: Where required exit signs are
installed, signs to provide exiting information for
people with vision impairment are not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5014
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
4 Loading Area and Exit from Serra Hall
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5021
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 2 JOB $90 $180
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5023
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
5 SE Exit Stairway from Serra Hall # 1 (fire exit)
Door Closer
Project Year:
Funding source:
Project:
404.2.9
PCODE ID03 1 JOB $25 $25
Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
5025
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5024
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3965, Packet Page 4170 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
4 JOB $170 $680
6" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5026
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
6 Men's Restroom (Serra 1)
Accessories
Project Year:
Funding source:
Project:
308.2.1
2 JOB $100 $200
Hand sanitizer: 47" AFF
SCD: 57" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5031
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5040
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5036
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3966, Packet Page 4171 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5028
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5027
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
45" from face of door to wall
PCODE ID27C Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5029
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5033
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
7 Women's Restroom (Serra 1)
Accessories
Project Year:
Funding source:
Project:
308.2.1
1 JOB $100 $100
SCD: 55" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5046
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3967, Packet Page 4172 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5052
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
67" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5047
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
9 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5043
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5041
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
45" from face of door
PCODE ID27C Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5042
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3968, Packet Page 4173 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5048
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
8 Men's Restroom (Serra 2)
Accessories
Project Year:
Funding source:
Project:
1 JOB $100 $100
Hand sanitizer: 46" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5058
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
Project Year:
Funding source:
Project:
308.2.1
1 JOB $100 $100
SCD: 58" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5066
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5068
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
67" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5067
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3969, Packet Page 4174 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5055
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5054
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
44.5" from face of door
PCODE ID27C Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5056
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5062
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
9 Women's Restroom (Serra 2)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3970, Packet Page 4175 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Accessories
Project Year:
Funding source:
Project:
308.2.1
3 JOB $100 $300
SCD: 55" AFF
Tissues: 50" AFF Hand Sanitizer: 49"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5077
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5080
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5081
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
67" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5075
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
9 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5070
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3971, Packet Page 4176 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5069
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
45" from face of door
PCODE ID27C Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5071
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5076
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
10 SW Stairs(fire exit) (Serra 2)
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5082
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3972, Packet Page 4177 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
4 JOB $170 $680
5" - 6" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5083
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
11 2 Sets of Stairs Serving Stage
Cross Section
Project Year:
Funding source:
Project:
505.7
16 LF $75 $1,200
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5084
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5085
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
12 Stairs to Green Room and Restroom 109B (dressing room) Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 2 JOB $400 $800
Restroom and green room: facility with a fire alarm
system, visual signal (strobe) not provided at
required type of common use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5090
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3973, Packet Page 4178 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Cross Section
Project Year:
Funding source:
Project:
505.7
16 LF $75 $1,200
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5088
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 2 JOB $25 $50
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5087
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
PCODE ID27CREF REF
Latch approach: At pull side, door does not have
clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide directional sign to ramp.
• As-Built Description:
• Proposed Solution:
5086
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5093
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5089
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3974, Packet Page 4179 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
13 Dressing Room 109C
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5098
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5094
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5095
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
14 Ramp Serving Stage
Clearance
Project Year:
Funding source:
Project:
505.5
40 LF $37 $1,480
2" to wall
PCODE ED04 Handrail: Clearance to wall is not 1-1/2".
Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5101
TBD
ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3975, Packet Page 4180 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Fire Alarm
Project Year:
Funding source:
Project:
309.2
1 JOB $75 $75
8.5%
PCODE IC03ANT Clear floor space (30" x 48" min.) at light switch along ramp not provided.
Remove or relocate existing furniture/obstructions
to provide clear access to light switch.
• As-Built Description:
• Proposed Solution:
• As-Built:
5104
TBD
ADAAG 4.27.2
CSAS 1117B.6.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Height
Project Year:
Funding source:
Project:
505.4
REF
32" AFF
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5103
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:
Funding source:
Project:
505.10.1
PCODE ED05REF REF
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.
Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
5102
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
15 NW Stairway Serra 2
Clearance
Project Year:
Funding source:
Project:
505.5
REF
1.75" to wall
PCODE ED04REF Handrail: Clearance to wall is not 1-1/2".
Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5111
TBD
ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Cross Section
Project Year:
Funding source:
Project:
505.7
160 LF $75 $12,000
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5110
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3976, Packet Page 4181 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 1 JOB $200 $200
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5107
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5106
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5109
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5105
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Stairway
Project Year:
Funding source:
Project:
PCODE II02B 72 LF $14 $1,008 Stairs: There is no 2" wide contrasting color strip 1" from nosing on top & bottom treads (required in
CA only).
Provide 2" wide contrasting color strip 1" from
nosing on top & bottom treads when altering area.
• As-Built Description:
• Proposed Solution:
5108
TBD CSAS 1133B.4.4
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3977, Packet Page 4182 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5112
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
16 NW Stairway Serra 2
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 2 JOB $50 $100
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5118
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5113
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
5114
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
1 JOB $1,850 $1,850
12" deep
PCODE IN06B Sink is more than 6 1/2" deep.
Provide additional sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5115
TBD
ADAAG 4.24.4
CSAS 1115B.4.7.1
Severity 2
Priority 2 General Fund
General Maintenance
17 Kitchen
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3978, Packet Page 4183 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5119
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE IN06B 1 JOB $1,850 $1,850 Sink is more than 6 1/2" deep.
Provide new sink. Remodel cabinet as needed.
• As-Built Description:
• Proposed Solution:
5121
TBD
ADAAG 4.24.4
CSAS 1115B.4.7.1
Severity 2
Priority 2 General Fund
General Maintenance
Project Year:
Funding source:
Project:
REF
12" deep
PCODE IN06BREF Sink is more than 6 1/2" deep.
Provide new sink. Remodel cabinet as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5120
TBD
ADAAG 4.24.4
CSAS 1115B.4.7.1
Severity 2
Priority 2 General Fund
General Maintenance
18 Escalator and Stairs to Level 2 (in lobby)
Cross Section
Project Year:
Funding source:
Project:
505.7
48 LF $75 $3,600
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5126
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Stairway
Project Year:
Funding source:
Project:
PCODE II02B 14 LF $14 $196
Stairs: There is no 2" wide contrasting color strip 1"
from nosing on top & bottom treads (required in
CA only).
Provide 2" wide contrasting color strip 1" from
nosing on top & bottom treads when altering area.
• As-Built Description:
• Proposed Solution:
5125
TBD CSAS 1133B.4.4
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3979, Packet Page 4184 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Project Year:
Funding source:
Project:
PCODE II02BNT 1 JOB $160 $160
Escalator: There is no 2" wide contrasting color
strip 1" from nosing on top & bottom treads
(required in CA only).
Provide 2" wide contrasting color strip 1" from
nosing on top & bottom treads when altering area.
• As-Built Description:
• Proposed Solution:
5124
TBD CSAS 1133B.4.4
Severity 3
Priority 5
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5127
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
19 Stairs to Level 3 from 1st Floor
Cross Section
Project Year:
Funding source:
Project:
505.7
92 LF $75 $6,900
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5128
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Stairway
Project Year:
Funding source:
Project:
PCODE II02B 16 LF $14 $224
Stairs: There is no 2" wide contrasting color strip 1"
from nosing on top & bottom treads (required in
CA only).
Provide 2" wide contrasting color strip 1" from
nosing on top & bottom treads when altering area.
• As-Built Description:
• Proposed Solution:
5130
TBD CSAS 1133B.4.4
Severity 3
Priority 5
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5129
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
20 Conference Center Offices (Staff Area)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3980, Packet Page 4185 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
14 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5133
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5131
TBD
CSAS 1133B.2.6
Severity 3
Priority 5
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.2
1 JOB $1,750 $1,750
No knee space
PCODE IN06A Sink does not have knee space min. 27" high x 19" deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
• As-Built:
5134
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $70,913.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3981, Packet Page 4186 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
1 Stairs and Escalator from Level 2 to Level 3 (Alvarado Lobby) Cross Section
Project Year:
Funding source:
Project:
505.7
48 LF $75 $3,600
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5136
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Stairway
Project Year:
Funding source:
Project:
PCODE II02B 16 LF $14 $224
Stairs: There is no 2" wide contrasting color strip 1"
from nosing on top & bottom treads (required in
CA only).
Provide 2" wide contrasting color strip 1" from
nosing on top & bottom treads when altering area.
• As-Built Description:
• Proposed Solution:
5138
TBD CSAS 1133B.4.4
Severity 3
Priority 5
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5137
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
2 Larkin Room I and II
Alarm Signal
Project Year:
Funding source:
Project:
702.1
PCODE IC05D 2 JOB $100 $200
Visual signal (strobe) is mounted on the ceiling,
less than 6" below the ceiling (if the intensity is
increased to penetrate smoke, a shorter dimension
may be permitted by the authority having
jurisdiction).
Install extension piece for signal device.
• As-Built Description:
• Proposed Solution:
5142
TBD
ADAAG 4.28.3(6)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06AREF REF
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5144
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3982, Packet Page 4187 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
PCODE ID03 2 JOB $25 $50
Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
5139
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Electrical
Project Year:
Funding source:
Project:
308.2.1 & 308.2.2
REF
42" - 64" AFF
PCODE IC01REF Electric switch or control mounted less than 36" or more than 48" above floor to center.
Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5141
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Operable Part
Project Year:
Funding source:
Project:
309.4
PCODE IC02 7 JOB $300 $2,100 Light switches require tight grasping, pinching, or twisting of the wrist with one hand.
Modify or replace the light switches to not require
tight grasping, pinching, or twisting of the wrist
with one hand.
• As-Built Description:
• Proposed Solution:
5140
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
2 JOB $1,750 $3,500
39" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5143
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
3 Dana Room
Alarm Signal
Project Year:
Funding source:
Project:
702.1
PCODE IC05D 1 JOB $100 $100
Visual signal (strobe) is mounted on the ceiling,
less than 6" below the ceiling (if the intensity is
increased to penetrate smoke, a shorter dimension
may be permitted by the authority having
jurisdiction).
Install extension piece for signal device.
• As-Built Description:
• Proposed Solution:
5150
TBD
ADAAG 4.28.3(6)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3983, Packet Page 4188 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
12 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5146
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Operable Part
Project Year:
Funding source:
Project:
309.4
PCODE IC02 2 JOB $300 $600
Operable part(s) require tight grasping, pinching, or
twisting of the wrist with one hand.
Modify or replace the operable part(s) to not require
tight grasping, pinching, or twisting of the wrist
with one hand.
• As-Built Description:
• Proposed Solution:
5145
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 1 JOB $90 $90
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5149
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5148
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
4 Corridor to Meeting Rooms
Door
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 1 JOB $200 $200
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5154
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3984, Packet Page 4189 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
15 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5155
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Drinking Fountain
Project Year:
Funding source:
Project:
602.2
1 JOB $3,200 $3,200
Knee clearance: 12" high
PCODE IA02 Wall- and post-mounted cantilevered units: Knee space not provided at drinking fountain (27" high,
8" deep, 30" wide from front of drinking fountain).
Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
5152
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
602.2
REF
12" deep
PCODE IA02BREF Wall- and post-mounted cantilevered units:
Drinking fountain less than 17"-19" deep (front to
back).
Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
5153
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5151
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
5 Stairs from Corridor to Exit
Cross Section
Project Year:
Funding source:
Project:
505.7
9 LF $75 $675
1.75"
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5157
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3985, Packet Page 4190 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
18 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5160
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Stairway
Project Year:
Funding source:
Project:
PCODE II02B 16 LF $14 $224
Stairs: There is no 2" wide contrasting color strip 1"
from nosing on top & bottom treads (required in
CA only).
Provide 2" wide contrasting color strip 1" from
nosing on top & bottom treads when altering area.
• As-Built Description:
• Proposed Solution:
5159
TBD CSAS 1133B.4.4
Severity 3
Priority 5
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5158
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
6 Men's Restroom
Accessories
Project Year:
Funding source:
Project:
2 JOB $100 $200
Hand sanitizer: 45"
SCD: 44"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5164
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5175
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3986, Packet Page 4191 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5170
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5162
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5161
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05CREF REF
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5169
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
7 Women's Restroom
Accessories
Project Year:
Funding source:
Project:
2 JOB $100 $200
Hand sanitizer: 47" AFF
SCD: 42" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5178
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3987, Packet Page 4192 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5185
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5182
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
13 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5177
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5176
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Second Floor $18,128.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3988, Packet Page 4193 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
1 Steinbeck Lobby
Door Closer
Project Year:
Funding source:
Project:
404.2.9
10 JOB $25 $250
12 - 15 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5189
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 5 JOB $90 $450
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5188
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Colton Rooms (Colton I, II, III)
Door Closer
Project Year:
Funding source:
Project:
404.2.9
3 JOB $25 $75
6 - 8 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5193
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.9
6 JOB $25 $150
12 - 15 lbs
PCODE ID03 At Exit doors: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5196
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 3 JOB $25 $75
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5195
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3989, Packet Page 4194 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Electrical
Project Year:
Funding source:
Project:
308.2.1 & 308.2.2
3 JOB $300 $900
56" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.
Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5194
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 3 JOB $90 $270
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5192
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
3 Ferrante Rooms (I, II, III)
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
11 - 14 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5199
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.9
6 JOB $25 $150
12 - 17 lbs
PCODE ID03 At exit doors: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5205
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 3 JOB $25 $75
At Exit doors: push side of door on accessible
route, bottom 10" does not have a smooth,
uninterrupted surface (required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5203
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3990, Packet Page 4195 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Electrical
Project Year:
Funding source:
Project:
308.2.1 & 308.2.2
3 JOB $300 $900
56" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.
Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5198
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
At room 3: Compliant sign identifying permanent
room or space not mounted 60" high to center on
nearest adjacent wall, on latch side if a single door
(located not to cause a Braille reader to stand within
the door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5197
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 3 JOB $90 $270
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5202
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 3 JOB $90 $270
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5201
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
4 Restroom Corridor
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
12 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5207
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3991, Packet Page 4196 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
5206
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
5 Women's Restroom
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5217
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
11 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5209
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
44" from face of door
PCODE ID27C Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5210
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5212
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
6 Men's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3992, Packet Page 4197 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
5223
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:
Funding source:
Project:
603.4
1 JOB $50 $50
67" AFF
PCODE WG03A Accessible coat hook not within reach range.
Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5227
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
12 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5219
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5218
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $5,000 $5,000
44" from face of door
PCODE ID27C Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").
Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
5220
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3993, Packet Page 4198 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Stall Door
Project Year:
Funding source:
Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5224
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
7 Steinbeck Forum East Entrance and Stairwell
Cross Section
Project Year:
Funding source:
Project:
505.7
44 LF $75 $3,300
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5232
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Door
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 1 JOB $200 $200
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5231
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
12 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5230
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
12 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5237
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3994, Packet Page 4199 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Height
Project Year:
Funding source:
Project:
505.4
REF
32" AFF
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5234
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
703.4.1
PCODE SA07 1 JOB $50 $50
At east entrance: Compliant sign identifying
permanent room or space not mounted 60" high to
center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
5229
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5238
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5233
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
8 Steinbeck Forum West Entrance and Stairwell
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3995, Packet Page 4200 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Cross Section
Project Year:
Funding source:
Project:
505.7
PCODE ED03A 44 LF $75 $3,300 Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
5242
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06ANT 1 JOB $200 $200
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
• As-Built Description:
• Proposed Solution:
5240
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
13 lbs
PCODE ID03 At entrance doors: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5241
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.9
2 JOB $25 $50
11 lbs
PCODE ID03 At exit doors: Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5246
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Height
Project Year:
Funding source:
Project:
505.4
PCODE ED02REF REF
Handrail gripping surface top not mounted between
34" and 38" above ramp surface or stair nosings.
Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
5244
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3996, Packet Page 4201 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5247
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5243
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
9 Steinbeck Forum Assembly Area and Stage
Clearance
Project Year:
Funding source:
Project:
505.5
REF
3.5" to wall
PCODE ED04REF Handrail: Clearance to wall is not 1-1/2".
Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5256
TBD
ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Cross Section
Project Year:
Funding source:
Project:
505.7
80 LF $75 $6,000
1.75" wide
PCODE ED03A Ornamental handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5255
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.7
8 LF $75 $600
1.75" wide
PCODE ED03A At ornamental handrail to stage: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5257
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3997, Packet Page 4202 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Disabled Seating
Project Year:
Funding source:
Project:
PCODE GB01E 1 JOB $150 $150
Aisle transfer seats not provided (1% of total fixed
seats, but not less than 1).
Provide aisle transfer seats without armrests on the
aisle side, or removable or folding armrests on the
aisle seat. Include sign or marker identifying such
seats. (NOTE: Space must be adjacent to regular
seating; can provide easily removable fixed seat).
• As-Built Description:
• Proposed Solution:
5251
TBD
ADAAG 4.1.3(19)(a)
CSAS 1104B.3.8
Severity 3
Priority 2 General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 8 LF $95 $760
At handrail to stage: not provided at stairs or ramp,
required on both sides (not required at curb ramps
or adjacent to seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5259
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 6 JOB $90 $540
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
5260
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10D 2 JOB $90 $180
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
5261
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
8 REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5258
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3998, Packet Page 4203 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
10 Dressing Room Steinbeck Forum
Accessories
Project Year:
Funding source:
Project:
308.2.1
1 JOB $100 $100
61" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5265
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
5 JOB $25 $125
8 - 10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5264
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 5 JOB $25 $125
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
5262
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 10 LF $95 $950
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
5266
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
5263
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 3999, Packet Page 4204 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Project Year:
Funding source:
Project:
606.2
REF
No knee space
PCODE IN06AREF Sink does not have knee space min. 27" high x 19" deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
• As-Built:
5269
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06 4 JOB $170 $680
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5267
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Third Floor $34,565.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4000, Packet Page 4205 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza Building Maintenance
Total Costs for Part: Interior $123,606.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4001, Packet Page 4206 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
110-0-1
Construction Management Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 353 Camino El Estero Building Maintenance
1 POT from Parking to Construction Management
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 4 LF $95 $380
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6037
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 12 LF $9 $108
Contrasting color strip not provided at all stair
nosings at steps to entrance (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
6036
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $488.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4002, Packet Page 4207 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
110-0-1
Construction Management Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 353 Camino El Estero Building Maintenance
Total Costs for Part: Exterior $488.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4003, Packet Page 4208 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
110-1-1
Construction Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 353 Camino El Estero Building Maintenance
2 Conference Room (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6041
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 3 JOB $250 $750
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6043
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
Door width + 6.5"
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6042
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 5
ADA-2010
General Fund
General Maintenance
3 Kitchen (Staff Only)
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6046
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
6047
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4004, Packet Page 4209 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
110-1-1
Construction Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 353 Camino El Estero Building Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
36" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
6044
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
6045
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
4 Restroom (Staff Only)
Accessories
Project Year:
Funding source:
Project:
3 JOB $100 $300
SCD: 48" AFF
SD: 42" AFF
PTD: 46" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6052
TBD CSAS 1115B.8.3
Severity 2
Priority 5
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $3,890.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4005, Packet Page 4210 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
110-1-1
Construction Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 353 Camino El Estero Building Maintenance
Total Costs for Part: Interior $3,890.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4006, Packet Page 4211 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
111-0-1
Doc's Lab Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 800 Cannery Row Building Maintenance
1 Main Entrance Stairs
Cross Section
Project Year:
Funding source:
Project:
505.7
REF
2.5" wide
PCODE ED03REF Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6845
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 14 LF $95 $1,330 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6843
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $1,330.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4007, Packet Page 4212 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
111-0-1
Doc's Lab Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 800 Cannery Row Building Maintenance
Total Costs for Part: Exterior $1,330.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4008, Packet Page 4213 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-0-1
Employee Lounge Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra Building Maintenance
2 Exterior Patio Area
Cross Section
Project Year:
Funding source:
Project:
505.7
12 LF $75 $900
3.25" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6907
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6908
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 15 LF $9 $135
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
6906
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $1,035.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4009, Packet Page 4214 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-0-1
Employee Lounge Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra Building Maintenance
Total Costs for Part: Exterior $1,035.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4010, Packet Page 4215 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-1-1
Employee Lounge Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra Building Maintenance
1 Employee's Lounge Room
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
37" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
6915
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
6916
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.5
PCODE IN06C 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.
Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6917
TBD
ADAAG 4.24.6
CSAS 1115B.4.7.1
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $1,870.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4011, Packet Page 4216 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-1-1
Employee Lounge Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra Building Maintenance
Total Costs for Part: Interior $1,870.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4012, Packet Page 4217 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
1 Accessible Space Serving Police Department (Lot El Cuartel) Minimum Number
Project Year:
Funding source:
Project:
208.2
PCODE EA01C 2 JOB $300 $600
At parking lot with 51-75 spaces, the number of
accessible spaces is less than required by code; 3
spaces required.
Provide required accessible parking spaces with
signs including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
6302
TBD
ADAAG 4.1.2(5)*
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:
Funding source:
Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).
Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
6303
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).
Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
6301
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
6300
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
4 2 Accessible Parking Spaces Serving E.O.C.
Parking
Project Year:
Funding source:
Project:
208.2; 502.1
PCODE EA07NT 1 JOB $90 $90
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).
Provide "Van Accessible" sign at space with aisle
located on passenger side.
• As-Built Description:
• Proposed Solution:
6320
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4013, Packet Page 4218 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).
Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
6322
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE EA04G 2 JOB $100 $200
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
6321
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
5 Ramp from E.O.C. to Fire Station No. 1
Top and Bottom Extension at
Ramps
Project Year:
Funding source:
Project:
505.10.1
4 JOB $170 $680
5" - 9" extensions
PCODE ED05 Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.
Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6324
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 18 LF $9 $162
Contrasting color strip not provided at all stair
nosings at corner stairs to lot (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
6325
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
7 1 Accessible Space Serving Fire Admin. and Police Admin.
Identification
Project Year:
Funding source:
Project:
502.6
PCODE EA04B 1 JOB $315 $315
Sign for accessible parking space is missing or noncompliant.
Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
6329
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4014, Packet Page 4219 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Parking
Project Year:
Funding source:
Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).
Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
6333
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04GREF REF
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
6330
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
9 Ramp Serving Fire Admin.
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
2 JOB $170 $340
9" extension
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6338
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:
Funding source:
Project:
505.10.1
2 JOB $170 $340
9" extension
PCODE ED05 Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.
Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6337
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02NT 12 LF $9 $108
Contrasting color strip not provided in correct
location (required in CA only).
Provide contrasting color strips at all exterior stair
treads when altering area.
• As-Built Description:
• Proposed Solution:
6339
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
10 Ramp Serving Police Admin. (Staff Only)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4015, Packet Page 4220 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
2 JOB $170 $340
9" extension
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6341
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:
Funding source:
Project:
505.10.1
2 JOB $170 $340
9" extension
PCODE ED05 Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.
Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6340
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 12 LF $9 $108
Clearly contrasting color strip at least 2" wide
placed parallel to and not more than 1" from the
nose of the step not provided at all stair nosings
(required in CA only).
Provide compliant contrasting color strips at all
exterior stair treads.
• As-Built Description:
• Proposed Solution:
6342
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
11 Exit Stairs Serving Police Admin.
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
2 JOB $170 $340
9" extension
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6345
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4016, Packet Page 4221 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 15 LF $9 $135
Clearly contrasting color strip at least 2" wide
placed parallel to and not more than 1" from the
nose of the step not provided at all stair nosings
(required in CA only).
Provide compliant contrasting color strips at all
exterior stair treads.
• As-Built Description:
• Proposed Solution:
6344
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
12 Exit Stairs Serving Fire Admin.
Handrail
Project Year:
Funding source:
Project:
505.3
PCODE ED10NT 10 LF $75 $750
Handrail: Gripping surface (rail top and sides)
interrupted by support or other obstruction.
Modify handrail as needed.
• As-Built Description:
• Proposed Solution:
6347
TBD
ADAAG 4.9.4(4)
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $6,298.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4017, Packet Page 4222 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Total Costs for Part: Exterior $6,298.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4018, Packet Page 4223 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
1 Police Department Lobby / Entrance
Carpet/Doormat
Project Year:
Funding source:
Project:
302.2
PCODE ID05A 1 JOB $75 $75
Doormat not securely attached to ground or floor
structure.
Attach doormat to floor surface or remove doormat.
• As-Built Description:
• Proposed Solution:
6355
TBD
ADAAG 4.5.3
CSAS 1124B.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $75 $75
Emergency phone does not have accessible
hardware.
Provide u-pull on existing emergency phone.
• As-Built Description:
• Proposed Solution:
6353
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 3 JOB $250 $750
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6357
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 2 JOB $25 $50
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6356
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 E.O.C. Operations Classroom (Fire Station No. 1)
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6362
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4019, Packet Page 4224 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
35.75" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
6360
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
6361
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
3 E.O.C. Print Room / Office
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
Door width + 8"
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6363
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6364
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
4 E.O.C. Unisex Restroom
Lavatory
Project Year:
Funding source:
Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.
Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6366
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4020, Packet Page 4225 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Signage
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
adjacent to existing sliding door. If wheelchair
accessible, include International Symbol of
Accessibility on sign.
• As-Built Description:
• Proposed Solution:
6365
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $3,590.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4021, Packet Page 4226 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Total Costs for Part: Police Admin. & E.O.C. Operation $3,590.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4022, Packet Page 4227 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-2-1
Police and Fire Annex Part: Fire Administration Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
1 Fire Admin. Lobby (Building A)
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6372
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6371
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Fire Admin. Conference Room
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6373
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6374
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6375
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $255.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4023, Packet Page 4228 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-2-1
Police and Fire Annex Part: Fire Administration Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street Building Maintenance
Total Costs for Part: Fire Administration $255.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4024, Packet Page 4229 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison Building Maintenance
1 Main Entrance and Apparatus Room
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 3 JOB $400 $1,200 At facility with a fire alarm system, visual signal (strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
6270
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
3 JOB $25 $75
8 - 12 lbs
PCODE ID03 Excessive force required to open door at entrance, gym and corridor.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6268
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6266
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
Door width + 4.5"
20" deep structural column.
PCODE ID23NT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6260
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Restroom
Project Year:
Funding source:
Project:
603
PCODE WA01NT 1 JOB $90 $90
Single accommodation restroom not accessible;
multiple compliance violations.
Provide directional sign to accessible public
restroom.
• As-Built Description:
• Proposed Solution:
6264
TBD
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
2 Corridor to Recreation Room and Kitchen
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4025, Packet Page 4230 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison Building Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
6273
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6272
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
3 Corridor Serving Sleeping Quarters and Restrooms
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 2 JOB $400 $800
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
6276
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Restroom
Project Year:
Funding source:
Project:
603
PCODE WA01A 2 JOB $90 $180
Multiple accommodation STAFF restrooms not
accessible; multiple compliance violations.
Provide compliant restrooms when remodeling
area. Provide directional sign to accessible public
restroom.
• As-Built Description:
• Proposed Solution:
6277
TBD
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
4 Corridor to Rear Lot and Accessible Restrooms
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 2 JOB $400 $800
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
6280
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4026, Packet Page 4231 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison Building Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
1 JOB $500 $500
Door width + 5"
PCODE ID24 Front approach: At push side, door at accessible restroom and sleeping quarter do not have clear and
level maneuvering space measuring door width x
48" (door width plus 12" if door has both, latch and
closer).
Remove door closer and patch door & door frame if
necessary.
• As-Built Description:
• Proposed Solution:
• As-Built:
6279
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
5 Accessible Unisex Restroom and Shower
Accessories
Project Year:
Funding source:
Project:
308.2.1
2 JOB $100 $200
PTD: 51" AFF
SCD: 63" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6288
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 1 JOB $400 $400
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
6284
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:
Funding source:
Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.
Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6286
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4027, Packet Page 4232 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison Building Maintenance
Operable Part
Project Year:
Funding source:
Project:
309.4
PCODE IC02NT 1 JOB $300 $300
Operable part(s) of shower head adjuster require
tight grasping, pinching, or twisting of the wrist
with one hand.
Modify or replace the operable part(s) of shower
head adjuster to not require tight grasping,
pinching, or twisting of the wrist with one hand.
• As-Built Description:
• Proposed Solution:
6296
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6281
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6282
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
6 Kitchen and Recreation Room (Staff Only)
Alarm Signal
Project Year:
Funding source:
Project:
215.1 & 702.1
PCODE IC05 2 JOB $400 $800
At facility with a fire alarm system, visual signal
(strobe) not provided at required type of common
use area.
Provide combination visual / audible signal device
connected to existing fire alarm system.
• As-Built Description:
• Proposed Solution:
6298
TBD
ADAAG 4.1.3(14) & 4.28.3
CSAS 1114B.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4028, Packet Page 4233 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison Building Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 2 JOB $250 $500
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6297
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6299
TBD
CSAS 1133B.2.6
Severity 3
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $7,570.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4029, Packet Page 4234 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison Building Maintenance
Total Costs for Part: Interior $7,570.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4030, Packet Page 4235 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-0-1
Fire Station No. 2 Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. Building Maintenance
1 POT from Sidewalk to Public Entrance
Tread Surface
Project Year:
Funding source:
Project:
504.4
15 LF $9 $135
12" change in level
PCODE EC02NT Contrasting color strip not provided along drop off between driveway.
Recommended: provide contrasting color striping
along drop off between driveway .
• As-Built Description:
• Proposed Solution:
• As-Built:
6546
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $135.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4031, Packet Page 4236 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-0-1
Fire Station No. 2 Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. Building Maintenance
Total Costs for Part: Exterior $135.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4032, Packet Page 4237 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. Building Maintenance
2 POT Through Apparatus Bay to Restroom
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 2 JOB $250 $500
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6529
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
3 Restroom Corridor
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 1 JOB $250 $250
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6531
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
4 Unisex Restroom
Lavatory
Project Year:
Funding source:
Project:
606.4
PCODE WD06REF REF
Lavatory: Accessible faucet (lever-operated, pushtype or electronically controlled) not provided at otherwise accessible lavatory.
Provide accessible faucet at accessible lavatory.
• As-Built Description:
• Proposed Solution:
6538
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6536
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4033, Packet Page 4238 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. Building Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6535
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $930.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4034, Packet Page 4239 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. Building Maintenance
Total Costs for Part: Interior $930.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4035, Packet Page 4240 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
116-1-1
Fire Station No. 3 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Dela Vina Building Maintenance
1 Main Entrance and Lobby
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6517
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
6518
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Apparatus Room and Restroom
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6521
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 5 JOB $250 $1,250 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6522
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Door Swing
Project Year:
Funding source:
Project:
404.2.4
REF
Door width + 10" to lavatory
56" from face of door to wall
PCODE ID23REF Restroom - Front approach: At pull side, door does not have clear and level maneuvering space
measuring door width plus 18" x 60" (CA only:
exterior door width plus 24").
Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6525
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4036, Packet Page 4241 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
116-1-1
Fire Station No. 3 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Dela Vina Building Maintenance
Lavatory
Project Year:
Funding source:
Project:
606.4
PCODE WD07REF REF
Lavatory: Self-closing faucet at accessible lavatory
does not remain open for at least 10 seconds.
Adjust self-closing faucet at accessible lavatory.
• As-Built Description:
• Proposed Solution:
6524
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $1,840.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4037, Packet Page 4242 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
116-1-1
Fire Station No. 3 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Dela Vina Building Maintenance
Total Costs for Part: Interior $1,840.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4038, Packet Page 4243 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-0-1
Gordon House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
1 Front Entrance to Gordon House
Cross Section
Project Year:
Funding source:
Project:
505.7
12 LF $75 $900
3.5" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2710
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.
Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
2713
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
2711
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 20 LF $9 $180
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2712
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
2 Accessible Parking at Rear of Facility (Dutra St)
Identification
Project Year:
Funding source:
Project:
502.6
PCODE EA04B 1 JOB $315 $315
Sign for accessible parking space is missing or noncompliant.
Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
2716
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4039, Packet Page 4244 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-0-1
Gordon House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
2717
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Total Costs for Floor: On-Site $1,725.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4040, Packet Page 4245 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-0-1
Gordon House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Total Costs for Part: Exterior $1,725.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4041, Packet Page 4246 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
1 Entrance Lobby
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
3040
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 City Attorney Staff Offices
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 5 JOB $250 $1,250 Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
3043
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07C 4 JOB $250 $1,000 Non-common use areas within this facility, such as offices, do not have accessible door hardware.
Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
3044
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
3 Accessible Entrance at Rear of Facility
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
3046
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
4 Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4042, Packet Page 4247 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Accessories
Project Year:
Funding source:
Project:
308.2.1
2 JOB $100 $200
PTD: 50"
SCD: 60"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3054
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
3049
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:
Funding source:
Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3052
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3051
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
5 Kitchen
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4043, Packet Page 4248 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Staff only door does not have accessible operating
hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
3021
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Sink
Project Year:
Funding source:
Project:
606.3
1 JOB $1,750 $1,750
38" AFF
PCODE IN06 Sink rim higher than 34" above floor.
Remodel sink cabinet to lower sink.
• As-Built Description:
• Proposed Solution:
• As-Built:
3023
TBD
ADAAG 4.24.2
CSAS 1115B.4.7.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
606.2
REF
No knee space
PCODE IN06AREF Sink does not have knee space min. 27" high x 19" deep x 30" wide.
Remodel sink cabinet.
• As-Built Description:
• Proposed Solution:
• As-Built:
3024
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
REF
9" deep
PCODE IN06BREF Sink is more than 6 1/2" deep.
Provide new sink. Remodel cabinet as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3025
TBD
ADAAG 4.24.4
CSAS 1115B.4.7.1
Severity 3
Priority 2 General Fund
General Maintenance
7 Communication and Outreach Building (Staff only)
Cross Section
Project Year:
Funding source:
Project:
505.7
PCODE ED03 18 LF $75 $1,350 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
3038
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4044, Packet Page 4249 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 2 JOB $250 $500
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
3031
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 18 LF $95 $1,710 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
3037
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 39 LF $9 $351
Contrasting color strip not provided at all stair
nosings (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
3039
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: Ground Floor $9,291.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4045, Packet Page 4250 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. Building Maintenance
Total Costs for Part: Interior $9,291.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4046, Packet Page 4251 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
119-0-1
Harbor Patrol/PD Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 417 Figueroa St. Building Maintenance
1 Main Entrance at Figueroa Street
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6855
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $250.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4047, Packet Page 4252 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
119-0-1
Harbor Patrol/PD Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 417 Figueroa St. Building Maintenance
Total Costs for Part: Exterior $250.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4048, Packet Page 4253 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
2 Accessible Parking Serving Housing Property Management Identification
Project Year:
Funding source:
Project:
502.6
PCODE EA04BNT 1 JOB $315 $315
Sign for accessible parking is not in front of space.
Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
6863
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:
Funding source:
Project:
208.2; 502.1
PCODE EA07REF REF
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).
Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
6861
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:
Funding source:
Project:
PCODE EA04GNT 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.
Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
6864
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
3 POT from Staff Lot to Police Parking Lot
Handrails
Project Year:
Funding source:
Project:
504.6
PCODE ED01 5 LF $95 $475
Handrail not provided at stairs to staff lot, required
on both sides (not required at curb ramps or
adjacent to seating areas).
Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6869
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:
Funding source:
Project:
PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.
Provide directional sign guiding persons to front
accessible entrance.
• As-Built Description:
• Proposed Solution:
6866
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 4 General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4049, Packet Page 4254 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06 1 JOB $170 $170
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
6868
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
3 JOB $170 $510
9" - 10" extensions
PCODE ED06 Stair handrail at stairs to staff lot does not extend horizontally 12" minimum beyond top nosing, and
one tread width sloped, plus 12" minimum
horizontally beyond the bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6870
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 24 LF $9 $216
Contrasting color strip not provided at all stair
nosings at stairs to staff lot (required in CA only).
Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
6871
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Project Year:
Funding source:
Project:
504.4
PCODE EC02NT 28 LF $9 $252
Contrasting color strip not provided in full width at
all stair nosings (required in CA only).
Provide contrasting color strips at full width of all
exterior stair treads when altering area.
• As-Built Description:
• Proposed Solution:
6867
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
4 Wooden Stairs to Designated Accessible Entrance
Cross Section
Project Year:
Funding source:
Project:
505.7
24 LF $75 $1,800
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6874
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4050, Packet Page 4255 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
3 JOB $170 $510
8" - 9" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6872
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02NT 50 LF $9 $450
Contrasting color strip is non-compliant at all stair
nosings (required in CA only).
Provide compliant contrasting color strips at all
exterior stair treads when altering area.
• As-Built Description:
• Proposed Solution:
6873
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
5 Stairs to Accessible Entrance
Cross Section
Project Year:
Funding source:
Project:
505.7
? LF $75 ?
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".
Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
7041
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of gate door on accessible route,
bottom 10" does not have a smooth, uninterrupted
surface (required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
7044
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:
Funding source:
Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
7042
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4051, Packet Page 4256 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
Tread Surface
Project Year:
Funding source:
Project:
504.4
PCODE EC02 24 LF $9 $216
Clearly contrasting color strip at least 2" wide
placed parallel to and not more than 1" from the
nose of the step not provided at all stair nosings
(required in CA only).
Provide compliant contrasting color strips at all
exterior stair treads.
• As-Built Description:
• Proposed Solution:
7040
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $5,209.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4052, Packet Page 4257 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
Total Costs for Part: Exterior $5,209.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4053, Packet Page 4258 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-1-1
Housing and Property Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
1 Entrance Lobby
Carpet/Doormat
Project Year:
Funding source:
Project:
302.2
PCODE ID05A 1 JOB $75 $75
Doormat not securely attached to ground or floor
structure.
Attach doormat to floor surface or remove doormat.
• As-Built Description:
• Proposed Solution:
6879
TBD
ADAAG 4.5.3
CSAS 1124B.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:
Funding source:
Project:
404.2.9
1 JOB $25 $25
10 lbs
PCODE ID03 Excessive force required to open door.
Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6875
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:
Funding source:
Project:
404.2.7
PCODE ID07NT 1 JOB $250 $250
Door does not have accessible operating hardware
at sliding door.
Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6881
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:
Funding source:
Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).
Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6876
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 Unisex Restroom
Accessories
Project Year:
Funding source:
Project:
1 JOB $100 $100
SD: 47" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.
Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6887
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .
APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4054, Packet Page 4259 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-1-1
Housing and Property Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. Building Maintenance
Door Hardware
Project Year: