405.1
20 LF $260 $5,200

3.2%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
6902
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.3
REF

12.4%
PCODE EF01REF Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6899
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Exterior Patio Area
Clear Width
Project Year:

Funding source:

Project:
403.5.1
1 JOB $50 $50
29" to trash bin & planter
PCODE EF08ANT Tree branches reduce walkway to less than 48" wide.

Trim tree to enlarge width of walk to 48".
• As-Built Description:
• Proposed Solution:
• As-Built:
6903
2011-12
ADAAG 4.3.3
CSAS 1133B.7.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
1 JOB $160 $160

0.75"
PCODE EF04 Walk: Grating has grid openings greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
6905
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Picnic Table
Project Year:

Funding source:

Project:
902.2
REF
9" deep
PCODE NH11AREF Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6911
2011-12
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4318, Packet Page 4523 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-0-1
Employee Lounge Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra CIP - General Fund
Ramps
Project Year:

Funding source:

Project:
303.4
1 JOB $2,000 $2,000
13"
PCODE EB01ANT Ramp needed to provide disabled access at steps or change of level along path of travel.

Remodel area to provide accessible picnic table at
accessible location.
• As-Built Description:
• Proposed Solution:
• As-Built:
6910
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
25 SF $25 $625

5.7% - 12.9%
PCODE EF07 Cross slope more than 1/4":12" (2%) at recess brick paver at corner of patio and building.

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6904
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 1
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.3
250 SF $25 $6,250

2.5% - 14.7%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope by resetting brick paver.
• As-Built Description:
• Proposed Solution:
• As-Built:
6909
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 1
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $17,829.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4319, Packet Page 4524 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-0-1
Employee Lounge Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra CIP - General Fund
Total Costs for Part: Exterior $17,829.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4320, Packet Page 4525 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-1-1
Employee Lounge Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra CIP - General Fund
1 Employee's Lounge Room
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400
1" at sliding door
PCODE ID02ANT Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6913
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.5
REF

0.5" - 1.75"
PCODE ID02AREF Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6912
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 26" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6914
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $2,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4321, Packet Page 4526 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
112-1-1
Employee Lounge Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Madison & Dutra CIP - General Fund
Total Costs for Part: Interior $2,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4322, Packet Page 4527 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
1 Accessible Space Serving Police Department (Lot El Cuartel) Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09REF REF
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Relocate parking and provide accessible path.
• As-Built Description:
• Proposed Solution:
6306
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
162 SF $12 $1,944

3.6% - 5%
PCODE EA05 Accessible parking space has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
6305
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:

PCODE EA04D 1 JOB $100 $100
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
6304
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
2 POT from Accessible Space to Police Department
Changes in Level
Project Year:

Funding source:

Project:
403.4
10 SF $21 $210

0.5" - 1" lip
PCODE EF03 Walk: Pavement dislocation creates abrupt change in level exceeding 1/2" in accessible route.

Remove, replace or repair area of pavement
sufficient to correct abrupt change in level.
• As-Built Description:
• Proposed Solution:
• As-Built:
6314
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Curb Ramp
Project Year:

Funding source:

Project:
406.2
REF

1.5"
PCODE EH02DREF Transition from ramp to gutter does not have a smooth transition.

Grind lip.
• As-Built Description:
• Proposed Solution:
• As-Built:
6310
2011-12
ADAAG 4.7.2
CSAS 1133B.5.3
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4323, Packet Page 4528 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Project Year:

Funding source:

Project:
405.3
1 JOB $2,500 $2,500

4.4%
PCODE EH02F Cross slope greater than 2%
Demolish existing and provide new curb ramp.
• As-Built Description:
• Proposed Solution:
• As-Built:
6311
2011-12
ADAAG 4.8.6
CSAS 1133B.5.3.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
406.4
REF
29"
PCODE EH05BREF Curb ramp: Less than 48" level space at top and 1:12 flared sides not provided.

Demolish existing and provide new curb ramp.
• As-Built Description:
• Proposed Solution:
• As-Built:
6312
2011-12
ADAAG 4.7.5; Fig.12(a)
CSAS 1127B.5.4
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
705.1
PCODE EH07A 1 JOB $250 $250
Detectable warning not provided where pedestrian
crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) at regular curb ramp.
• As-Built Description:
• Proposed Solution:
6309
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
405.1
256 LF $260 $66,560

10.9%
PCODE EF01A Sidewalk to Police entrance: Slope greater than 1:20 (5.0%), and walk does not comply with
requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
6315
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
303.1
PCODE EF10 240 SF $5 $1,200 Walk along sidewalk pavement and concrete:

Irregular surface in pavement.

Smooth pavement surface; grind or refinish surface.
• As-Built Description:
• Proposed Solution:
6308
2011-12
ADAAG 4.5.2
CSAS 1133B.7.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Curb Ramp at Back of E.O.C.

March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4324, Packet Page 4529 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Curb Ramp
Project Year:

Funding source:

Project:
705.1
PCODE EH07A 1 JOB $250 $250
Detectable warning not provided where pedestrian
crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) at regular curb ramp.
• As-Built Description:
• Proposed Solution:
6316
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 2 Accessible Parking Spaces Serving E.O.C.

Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 7 LF $27 $189
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6319
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
500 SF $12 $6,000

4.3% - 5.4%
PCODE EA05 Accessible parking space has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
6318
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:

PCODE EA04D 1 JOB $100 $100
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
6317
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
5 Ramp from E.O.C. to Fire Station No. 1
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4325, Packet Page 4530 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Change in Direction
Project Year:

Funding source:

Project:
405.7.4
35 SF $45 $1,575
56"
PCODE EB08 Landing at change of direction not at least
60"x60" (CA only: 72"x width of ramp runs).

Modify ramp bottom landing to 72" length.
• As-Built Description:
• Proposed Solution:
• As-Built:
6323
2011-12
ADAAG 4.8.4(3)
CSAS 1133B.5.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
160 SF $25 $4,000

2.4% - 3.8%
PCODE EF07 Cross slope along building more than
1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6326
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
25 SF $25 $625

6.8%
PCODE EF01NT Stair top landing slopes greater than 1:20 (5.0%), and landing does not comply with requirements for
stairs.

Modify stairs top landing slope to 2% or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6327
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Exit Ramp from E.O.C. to Fire Station No. 1
Change in Direction
Project Year:

Funding source:

Project:
405.7.4
PCODE EB08 60 SF $45 $2,700 Landing at change of direction not at least 60"x60" (CA only: 72"x width of ramp runs).

Modify ramp bottom landings to 72" length.
• As-Built Description:
• Proposed Solution:
6328
2011-12
ADAAG 4.8.4(3)
CSAS 1133B.5.4
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 1 Accessible Space Serving Fire Admin. and Police Admin.

Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
252 SF $12 $3,024

4.3%
PCODE EA05 Accessible parking space has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
6334
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4326, Packet Page 4531 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Parking
Project Year:

Funding source:

Project:

PCODE EA04D 1 JOB $100 $100
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
6331
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
Parking Aisle
Project Year:

Funding source:

Project:

PCODE EA02C 1 JOB $200 $200
Accessible parking aisle is not located on the
passenger side (required in CA only).

Modify parking aisle(s) to create accessible space
by restriping.
• As-Built Description:
• Proposed Solution:
6332
2011-12 CSAS 1129B.3.1
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
8 Curb Ramp Serving Fire and Police Admin.

Curb Ramp
Project Year:

Funding source:

Project:
406.3
1 JOB $2,000 $2,000
R flare: 10.6%
PCODE EH05A Side slopes more than 1:10 (10%).

Modify curb ramp. Demolish side slopes and
replace with 1:10 side slopes if 48" level top
landing is provided.
• As-Built Description:
• Proposed Solution:
• As-Built:
6336
2011-12
ADAAG 4.7.5
CSAS 1127B.5.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
705.1
PCODE EH07AREF REF
Detectable warning not provided where pedestrian
crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) at regular curb ramp.
• As-Built Description:
• Proposed Solution:
6335
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
11 Exit Stairs Serving Police Admin.

Vertical Clearance
Project Year:

Funding source:

Project:
307.4
24 LF $100 $2,400
AC Unit: 22" protrusion at 71" AFF
PCODE EG01A Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6343
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
12 Exit Stairs Serving Fire Admin.

March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4327, Packet Page 4532 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
24 LF $100 $2,400
AC Unit: 22" protrusion at 71" AFF
PCODE EG01A Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6346
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
13 POT to Fire Station No. 1 Entrance
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 6 LF $27 $162
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6349
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
200 SF $25 $5,000

5.5%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6348
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $103,489.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4328, Packet Page 4533 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-0-1
Police and Fire Annex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Total Costs for Part: Exterior $103,489.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4329, Packet Page 4534 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
1 Police Department Lobby / Entrance
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Emergency Phone: 6" protrusion at 50"
AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6351
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Display window: 7.5" protrusion at 48"
AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6354
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
43" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
6358
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:
704.2.2
REF
Emergency Phone: 56" AFF
PCODE IB02REF Telephone mounting height more than 48" to highest operable part of phone.

Lower telephone enclosure and phone.
• As-Built Description:
• Proposed Solution:
• As-Built:
6352
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
405.1
64 LF $260 $16,640

13.6%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
6350
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4330, Packet Page 4535 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
2 E.O.C. Operations Classroom (Fire Station No. 1)
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 26" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6359
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 E.O.C. Unisex Restroom
Accessories
Project Year:

Funding source:

Project:

PCODE WG02BREF REF
Toilet paper dispenser or disposal container
protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
6369
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 14" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6368
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 44" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6367
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4331, Packet Page 4536 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75
SCD: 2" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6370
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $19,265.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4332, Packet Page 4537 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-1-1
Police and Fire Annex Part: Police Admin. & E.O.C. Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Total Costs for Part: Police Admin. & E.O.C. Operation $19,265.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4333, Packet Page 4538 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-2-1
Police and Fire Annex Part: Fire Administration Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
2 Fire Admin. Conference Room
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
Door width + 13"
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6376
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $50.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4334, Packet Page 4539 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
113-2-1
Police and Fire Annex Part: Fire Administration Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 610 Pacific Street CIP - General Fund
Total Costs for Part: Fire Administration $50.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4335, Packet Page 4540 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison CIP - General Fund
1 Main Entrance and Apparatus Room
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

8.2%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6259
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

12.6%
PCODE ID11NT Surface of required maneuvering clearance at Division Chief Office door slopes more than
1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6265
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6261
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Elevator
Project Year:

Funding source:

Project:

PCODE IK01REF REF
Elevator not provided in multistory building.

Staff only. Provide all accessible programs on
accessible ground floor.
• As-Built Description:
• Proposed Solution:
6267
2011-12
ADAAG 4.1.3(5)
CSAS 1007.2.1
Severity 3
Priority 4 General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Phone: 5" protrusion at 55" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6269
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4336, Packet Page 4541 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
Door bell: 52" AFF
Emergency Phone: 51" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6262
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:
1 JOB $2,220 $2,220

8.2% within clear space
PCODE IB01NT Emergency Telephone: Clear floor space, 30" wide x 48" out from wall, not provided.

Provide clear space in front of telephone, 30" wide
x 48" out from wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6263
2011-12
ADAAG 4.31.2
CSAS 1117B.2.2
Severity 2
Priority 3 General Fund
City ADA Transition Plan Upgrade
2 Corridor to Recreation Room and Kitchen
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

9.9%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6271
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
F.E. Cabinet: 65" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6274
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Corridor Serving Sleeping Quarters and Restrooms
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Phone: 5" protrusion at 58" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6275
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4337, Packet Page 4542 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison CIP - General Fund
4 Corridor to Rear Lot and Accessible Restrooms
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Phone: 5" protrusion at 58" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6278
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Accessible Unisex Restroom and Shower
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
58" to lavatory
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Relocate lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
6283
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 51.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6292
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 39.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6293
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4338, Packet Page 4543 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison CIP - General Fund
Project Year:

Funding source:

Project:
604.5
REF
35" AFF
PCODE WB07CREF Grab bars not at 33" to 36" from floor (CA only:
33" from floor if no tank toilet).

Relocate accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
6294
2011-12
ADAAG 4.16.4
CSAS 1115B.4.1.3.1 & 2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
REF

35.25" AFF
PCODE WD02REF Lavatory: Fixture rim or counter height more than 34" above floor.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6285
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
REF
PTD: 9" protrusion at 51" AFF
PCODE EG04REF Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6289
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Shower
Project Year:

Funding source:

Project:
1 JOB $500 $500
48" - 67"
PCODE WF05B CA only: Mounting height of shower spray bracket exceeds 48" max. or is more than 27" from rear
edge of folding seat.

Provide or remount shower spray bracket within
27" from rear edge of seat.
• As-Built Description:
• Proposed Solution:
• As-Built:
6295
2011-12 CSAS 1115B.4.4.5.3
Severity 1
Priority 5
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
608.4
PCODE WF07 1 JOB $550 $550
In 36" x 36" (CA: 30" x 60") stall, seat at 17" to 19"
height above floor opposite controls not provided
(CA only: folding seat at 18").

Provide new, or relocate, folding wall-mounted
shower seat.
• As-Built Description:
• Proposed Solution:
6291
2011-12
ADAAG 4.21.3
CSAS 1115B.4.4.8.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4339, Packet Page 4544 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
19" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6287
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $5,000 $5,000
45" to corner wall
PCODE WB03A CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Provide alternate water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6290
2011-12 CSAS 1115B.3.2.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $16,070.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4340, Packet Page 4545 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
114-1-1
Fire Station No. 1 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Madison CIP - General Fund
Total Costs for Part: Interior $16,070.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4341, Packet Page 4546 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-0-1
Fire Station No. 2 Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. CIP - General Fund
1 POT from Sidewalk to Public Entrance
Electrical
Project Year:

Funding source:

Project:
309.2
REF

2.5%
PCODE IC06BREF Clear floor space is not 30" x 48" minimum at all switches, outlets and other controls.

Re-grade and provide clear floor space in front of
door bell.
• As-Built Description:
• Proposed Solution:
• As-Built:
6545
2011-12 4.1.2(12)/4.1.3(13)
&4.27.2
ADAAG
1117B.6.2 CSAS
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Old telephone box: 7.5" protrusion at 44"
AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6547
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
200 SF $25 $5,000

2.3% - 8.0%
PCODE EF07 Cross slope more than 1/4":12" (2%) pavement to entrance and at door bell and phone.

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6544
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:

REF

4.1% within clear space
PCODE IB01REF Telephone: Clear floor space, 30" wide x 48" out from wall, not provided.

Provide clear space in front of telephone, 30" wide
x 48" out from wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6543
2011-12
ADAAG 4.31.2
CSAS 1117B.2.2
Severity 2
Priority 3 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
704.2.2
1 JOB $100 $100
Emergency Phone: 54" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower phone to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6542
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $5,200.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4342, Packet Page 4547 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-0-1
Fire Station No. 2 Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. CIP - General Fund
Total Costs for Part: Exterior $5,200.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4343, Packet Page 4548 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. CIP - General Fund
1 Public Entrance
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

2.6%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6526
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
REF

0.5"
PCODE ID02REF Existing threshold at door is 3/4" high or less but without a beveled edge on both sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
6527
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 POT Through Apparatus Bay to Restroom
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
2 LF $100 $200
Eye wash station: 5" protrusion at 40"
AFF
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6528
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Restroom Corridor
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Door width + 10"
PCODE ID23 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Change hinge to latch side and relocate shelving.
• As-Built Description:
• Proposed Solution:
• As-Built:
6530
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4344, Packet Page 4549 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. CIP - General Fund
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
28" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6534
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
REF
Knee space: 23" high
PCODE WD04REF Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6539
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
6532
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Turning Space
Project Year:

Funding source:

Project:
603.2.1
PCODE WC01REF REF
Wheelchair clearance: Clear space, floor to 27"
high with a diameter of 60", not provided (space
56" x 63" acceptable).

Provide wheelchair clearance space in restroom.
• As-Built Description:
• Proposed Solution:
6540
2011-12
ADAAG 4.22.3
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Urinal
Project Year:

Funding source:

Project:
605.2
REF
24" AFF
PCODE WE02REF Fixture mounted with rim more than 17" above floor.

Provide accessible urinal. Remodel restroom as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6537
2011-12
ADAAG 4.18.2
CSAS 1115B.4.2.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4345, Packet Page 4550 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:

REF
26" in front of water closet
PCODE WB03AREF CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Remodel restroom to provide at least 48" in front of
water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6533
2011-12 CSAS 1115B.3.2.1
Severity 1
Priority 5
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $34,300.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4346, Packet Page 4551 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
115-1-1
Fire Station No. 2 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 558/582 Hawthorne St. CIP - General Fund
Total Costs for Part: Interior $34,300.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4347, Packet Page 4552 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
116-1-1
Fire Station No. 3 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Dela Vina CIP - General Fund
1 Main Entrance and Lobby
Ramps
Project Year:

Funding source:

Project:
303.4
PCODE EB01A 92 SF $100 $9,200 Ramp needed to provide disabled access at steps or change of level along path of travel.

Provide new concrete ramp with handrails and
landings to entrance, emergency phone, and door
bell.
• As-Built Description:
• Proposed Solution:
6516
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Apparatus Room and Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF

27.5" clear opening width
PCODE ID01REF Restroom door has less than 32" clear opening width when 90° open (CA only:...or has leaf size
less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6523
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
6519
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
26" in front of water closet
PCODE WB03REF Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6520
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $39,200.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4348, Packet Page 4553 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
116-1-1
Fire Station No. 3 Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Dela Vina CIP - General Fund
Total Costs for Part: Interior $39,200.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4349, Packet Page 4554 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-0-1
Gordon House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
2 Accessible Parking at Rear of Facility (Dutra St)
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
45 SF $12 $540

2.3% - 3.2%
PCODE EA05 Portions of accessible parking space surface has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
2715
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:
502.3
PCODE EA02B 1 JOB $200 $200
Accessible parking space does not have 5' wide
access aisle; 8' wide for van accessible aisle (CA
only: aisle spaces need to be 18' in length).

Modify parking aisle(s) to create accessible space
by restriping.
• As-Built Description:
• Proposed Solution:
2714
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 POT from Accessible Parking to Ramp
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

9.4%
PCODE ID11NT At wooden entrance gate: Surface of required maneuvering clearance at door slopes more than
1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
2718
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
160 SF $25 $4,000

5.3% - 8.0%
PCODE EF01NT Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Remodel area to provide ramp with handrails and
landings.
• As-Built Description:
• Proposed Solution:
• As-Built:
3016
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Ramp to Gordon House at Rear Entrance
Clear Width
Project Year:

Funding source:

Project:
405.5
15 LF $75 $1,125
42" wide
PCODE EB10 Concrete ramp: Width (between handrails) less than 36" (CA only: less than 48" or less than 60" if
occupant load is 300 or more).

Modify ramp width to 48" or 60" as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
3017
2011-12
ADAAG 4.8.3
CSAS 1133B.5.2
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4350, Packet Page 4555 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-0-1
Gordon House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Length
Project Year:

Funding source:

Project:
405.7.3
20 SF $45 $900
57" to stair handrail
PCODE EB07 Landing less than 60" long. (CA only: 72"x width of ramp runs at bottom landing).

Modify ramp landing.
• As-Built Description:
• Proposed Solution:
• As-Built:
3018
2011-12
ADAAG 4.8.4(2)
CSAS 1133B.5.4.2
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $7,765.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4351, Packet Page 4556 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-0-1
Gordon House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Total Costs for Part: Exterior $7,765.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4352, Packet Page 4557 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
1 Entrance Lobby
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
29" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide directional information to accessible rear
entrance.
• As-Built Description:
• Proposed Solution:
• As-Built:
3042
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
REF
4" step
PCODE ID02AREF Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
3041
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 City Attorney Staff Offices
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" - 30" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3045
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Accessible Entrance at Rear of Facility
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3047
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4353, Packet Page 4558 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
Door width + 12" to partition
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3048
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
28" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3050
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
44" from face of door to partition
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3060
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 16.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3058
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4354, Packet Page 4559 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 48.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3057
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3053
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $100 $100
33" in front of WC
PCODE WB03NT Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Relocate bookshelves and furniture items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3056
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Turning Space
Project Year:

Funding source:

Project:
603.2.1
PCODE WC01REF REF
Wheelchair clearance: Clear space, floor to 27"
high with a diameter of 60", not provided (space
56" x 63" acceptable).

Relocate furniture items to provide adequate
wheelchair clearance.
• As-Built Description:
• Proposed Solution:
3059
2011-12
ADAAG 4.22.3
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
19" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3055
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4355, Packet Page 4560 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
5 Kitchen
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

7.7%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
3020
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
25" clear opening width
73" high
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3019
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
28" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3022
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
SD: 57" AFF at 19" deep
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3026
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Private Staff Restroom
Door Threshold
Project Year:

Funding source:

Project:

REF
8"
PCODE ID02BREF Door inaccessible due to threshold or step at door more than 6" high.

Provide ramp including handrails and compliant
landings, matching floor level inside door (+/-1/4").
• As-Built Description:
• Proposed Solution:
• As-Built:
3028
2011-12
ADAAG 4.8.5
CSAS 1133B.2.4.1
Severity 3
Priority 4 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4356, Packet Page 4561 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01REF REF
Single accommodation restroom not accessible;
multiple compliance violations.

Provide directional information to accessible
restroom.
• As-Built Description:
• Proposed Solution:
3027
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 Communication and Outreach Building (Staff only)
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3029
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
22" clear opening width
PCODE ID01 Restroom door on accessible route has less than 32" clear opening width when 90° open (CA only:...or
has leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
3030
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 1
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Elevator
Project Year:

Funding source:

Project:

PCODE IK01REF REF
Elevator not provided in multistory building.

Relocate program when meeting with non staff.
• As-Built Description:
• Proposed Solution:
3036
2011-12
ADAAG 4.1.3(5)
CSAS 1007.2.1
Severity 3
Priority 4 General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01A 1 JOB $35,000 $35,000 Multiple accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide accessible restroom with
one accessible stall, lavatory (and one urinal at
Men's).
• As-Built Description:
• Proposed Solution:
3032
2011-12
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4357, Packet Page 4562 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
PCODE WB04REF REF
Less than 95" from back wall to front wall of side
entry toilet stall when door swings inward, or less
than 92" if water closet is wall-hung (CA only: Less
than 60" from front of water closet to opposite wall
in side entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
3034
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.2
Severity 3
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.8.1.1
PCODE WB06REF REF
Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
3033
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.8.1.1
PCODE WB06REF REF
Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
3035
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $57,100.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4358, Packet Page 4563 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
117-1-1
Gordon House Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Total Costs for Part: Interior $57,100.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4359, Packet Page 4564 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
119-0-1
Harbor Patrol/PD Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 417 Figueroa St. CIP - General Fund
1 Main Entrance at Figueroa Street
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400

4.5"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6856
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4360, Packet Page 4565 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
119-0-1
Harbor Patrol/PD Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 417 Figueroa St. CIP - General Fund
Total Costs for Part: Exterior $400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4361, Packet Page 4566 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
1 POT from Sidewalk to Lift
Elevator
Project Year:

Funding source:

Project:

PCODE IK01NT 1 JOB $15,000 $15,000 Existing chair lift is broken down in multistory building.

Replace existing with new enclosed lift with two
stops.
• As-Built Description:
• Proposed Solution:
6859
2011-12
ADAAG 4.1.3(5)
CSAS 1007.2.1
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
40 SF $25 $1,000

5.2% - 6.0%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6858
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Accessible Parking Serving Housing Property Management Parking
Project Year:

Funding source:

Project:
502.2
1 JOB $5,000 $5,000

8.5' wide
PCODE EA02A Accessible parking space smaller than 8' wide (CA only: 9' x 18').

Provide accessible on-street parking and access
route including curb ramp.
• As-Built Description:
• Proposed Solution:
• As-Built:
6865
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
502.3
REF

9.5' long
PCODE EA02BREF Accessible parking space does not have 5' wide access aisle; 8' wide for van accessible aisle (CA
only: aisle spaces need to be 18' in length).

Modify parking aisle(s) to create accessible space
by restriping.
• As-Built Description:
• Proposed Solution:
• As-Built:
6862
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE EA04DREF REF
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
6860
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
5 Stairs to Accessible Entrance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4362, Packet Page 4567 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400

2.5"
PCODE ID02A Gate door at stair entrance inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
7043
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $21,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4363, Packet Page 4568 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-0-1
Housing and Property Management Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
Total Costs for Part: Exterior $21,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4364, Packet Page 4569 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-1-1
Housing and Property Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
1 Entrance Lobby
Corridor
Project Year:

Funding source:

Project:
1 JOB $50 $50
31" to cabinet
PCODE IH03A Corridor, for occupant load less than 10, less than 36" wide.

Remove or relocate furniture and storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6882
2011-12
ADAAG 4.3.3
CSAS 1133B.3.1
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
41" to bench
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6877
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 9"
PCODE ID23B Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6878
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
43" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
6880
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4365, Packet Page 4570 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-1-1
Housing and Property Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
TPD: 44" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6895
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 50.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6893
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5
1 JOB $260 $260
36" AFF
PCODE WB07C Grab bars not at 33" to 36" from floor (CA only:
33" from floor if no tank toilet).

Relocate accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
6894
2011-12
ADAAG 4.16.4
CSAS 1115B.4.1.3.1 & 2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $900 $900

35.25" AFF
PCODE WD02A Lavatory: Fixture rim or counter height more than 34" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6886
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
REF
Shelf: 12" protrusion at 58" AFF
PCODE EG04REF Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6890
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4366, Packet Page 4571 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-1-1
Housing and Property Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
Shelf & first aid kit: 59" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6888
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:
1 JOB $2,000 $2,000
24"
PCODE WB01A CA only: Less than 32" from side of water closet to far side of stall wall or 28" to adjacent fixture.

Remove adjacent fixture and provide new enclosure
at accessible water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6892
2011-12 CSAS 1115B.4.1.1
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
6885
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $7,045.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4367, Packet Page 4572 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
120-1-1
Housing and Property Management Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 669 Van Buren St. CIP - General Fund
Total Costs for Part: Interior $7,045.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4368, Packet Page 4573 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
123-0-1
Ketcham House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 512 Pierce St. CIP - General Fund
1 POT from Acc Parking to Back Accessible Entrance
Slope
Project Year:

Funding source:

Project:
403.3
64 SF $25 $1,600

3.2% - 5.7%
PCODE EF07 Brick paver walk cross slope more than
1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5767
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Front Stair Entrance at Ketcham House
Nosings
Project Year:

Funding source:

Project:
504.5
18 LF $20 $360
1" not beveled
PCODE EC01 Stair nosings project more than 1-1/2" past face of riser and/or are not beveled on underside 60° min.
from horizontal.

Modify stair nosings.
• As-Built Description:
• Proposed Solution:
• As-Built:
5981
2011-12
ADAAG 4.9.3
CSAS 1133B.4.5.2
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $1,960.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4369, Packet Page 4574 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
123-0-1
Ketcham House Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 512 Pierce St. CIP - General Fund
Total Costs for Part: Exterior $1,960.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4370, Packet Page 4575 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
123-1-1
Ketcham House Part: Interior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 512 Pierce St. CIP - General Fund
1 Entrance Lobby
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
REF
5"
PCODE ID02AREF Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
7018
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150

41.5" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
7020
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Copy Room (Staff Only)
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
PTD: 58" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
7027
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Unisex Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
46" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
7035
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4371, Packet Page 4576 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
123-1-1
Ketcham House Part: Interior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 512 Pierce St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
39" to drawers
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
7032
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600

57.5" to lavatory and wall
PCODE ID23B Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
7030
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Doormat
Project Year:

Funding source:

Project:
302.2
PCODE ID05 1 JOB $500 $500
Doormat hinders access to disabled persons.

Provide new doormat; recess or attach at edges.
• As-Built Description:
• Proposed Solution:
7031
2011-12
ADAAG 4.5.3
CSAS 1124B.3
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 14" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
7037
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
7038
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4372, Packet Page 4577 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
123-1-1
Ketcham House Part: Interior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 512 Pierce St. CIP - General Fund
Project Year:

Funding source:

Project:
609.3
REF
15" above SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
7036
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $50 $50
45" to trash bin
48" to wall
PCODE WB03NT Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Relocate trash bin.
• As-Built Description:
• Proposed Solution:
• As-Built:
7039
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

19.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
7034
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $4,625.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4373, Packet Page 4578 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
123-1-1
Ketcham House Part: Interior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 512 Pierce St. CIP - General Fund
Total Costs for Part: Interior $4,625.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4374, Packet Page 4579 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-0-1
Maritime Museum Community Room and Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
POT from Accessible Parking Spaces (2) Near Main Entrance to Restrooms
1 Walk
Project Year:

Funding source:

Project:
405.1
35 LF $260 $9,100

6.3% - 9.2%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
6571
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
POT from Accessible Parking Spaces (8) Near Harbor to Community Room
2 Slope
Project Year:

Funding source:

Project:
403.3
400 SF $25 $10,000

2.2% - 3.3%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope (small section of walkway
between anchor statue and museum).
• As-Built Description:
• Proposed Solution:
• As-Built:
6573
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Men's Restroom
Accessories
Project Year:

Funding source:

Project:

REF
TPD: 5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6588
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 4.25"
PCODE ID23BNT Front approach: At stall door, pull side, door does not have clear and level maneuvering space
measuring door width plus 18" x 60" (CA only:
exterior door width plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6585
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4375, Packet Page 4580 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-0-1
Maritime Museum Community Room and Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
3" to souvenir machine
PCODE ID24A Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6575
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6587
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 57" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6578
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
BCS: 18" protrusion at 34" AFF when
down
PCODE EG04NT Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6582
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6584
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4376, Packet Page 4581 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-0-1
Maritime Museum Community Room and Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Urinal
Project Year:

Funding source:

Project:
605.3
1 JOB $1,500 $1,500
32" wide
42" deep
PCODE WE04A 36" wide clearance in front of accessible urinal not provided when walls or partitions project more than
24" from the front edge of 30" x 48" clear space.

Provide 36" clear floor space in front of accessible
urinal. Remodel restroom as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6583
2011-12
ADAAG 4.18.3
CSAS 1115B.4.2.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
39" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6603
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
TPD: 5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6602
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 38" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6601
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4377, Packet Page 4582 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-0-1
Maritime Museum Community Room and Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Project Year:

Funding source:

Project:
609.3
3 REF
SCD, Shelf & TPD: 6" to 9"
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6604
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
BCS: 19" protrusion at 33" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6599
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
307.2
REF
EHD: 10" protrusion at 56" AFF
PCODE EG04REF Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6592
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6594
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
6600
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $24,775.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4378, Packet Page 4583 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-0-1
Maritime Museum Community Room and Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Total Costs for Part: Exterior $24,775.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4379, Packet Page 4584 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-1-1
Maritime Museum Community Room and Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
1 Entrance and Community Room
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
9" deep to table leg
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6550
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
3 JOB $100 $300
Light fixture: 9" protrusion at 67" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6551
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
TV mounting bracket: 20" protrusion at
54" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6552
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Kitchen
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $250 $250
Phone: 62" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower telephone enclosure and phone.
• As-Built Description:
• Proposed Solution:
• As-Built:
6554
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4380, Packet Page 4585 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-1-1
Maritime Museum Community Room and Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Tray Pass-thru
Project Year:

Funding source:

Project:
1 JOB $3,300 $3,300
Food pass through counter: 43.5" AFF
PCODE FB04NT Food tray pass-thru at institutional cafeteria has lower edge higher than 34" above floor.

Remodel pass-thru and counter to be 34" max.
above floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
6553
2011-12
ADAAG 5.2
CSAS 1122B.4
Severity 2
Priority 2 General Fund
City ADA Transition Plan Upgrade
3 Restroom (Unisex)
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
TPD: 53" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6567
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
TPD: 5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6565
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $900 $900
49" to lavatory
PCODE ID23BNT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Install smaller lavatory to provide the required
maneuvering space.
• As-Built Description:
• Proposed Solution:
• As-Built:
6569
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 16" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6563
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4381, Packet Page 4586 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-1-1
Maritime Museum Community Room and Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 39.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6562
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
REF
TPD: 0.5" below SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6566
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
REF

34.75" AFF
PCODE WD02AREF Lavatory: Fixture rim or counter height more than 34" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6570
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
16" o.c.

PCODE WB02 Less than 18" from near side wall to center line of water closet (2010 ADAAG: 16"-18").

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6564
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $5,000 $5,000
43"
PCODE WB03A CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Remodel restroom to provide at least 48" in front of
water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6568
2011-12 CSAS 1115B.3.2.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $16,625.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4382, Packet Page 4587 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
125-1-1
Maritime Museum Community Room and Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 5 Custom House Plaza CIP - General Fund
Total Costs for Part: Interior $16,625.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4383, Packet Page 4588 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
129-0-1
Osio Rodriquez Adobe Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 380 Alvarado St. CIP - General Fund
1 Stairs to Upper Level
Elevator
Project Year:

Funding source:

Project:

PCODE IK01REF REF
Elevator not provided in multistory building.

Provide new elevator with two stops or provide city
program or service at alternate accessible location.
• As-Built Description:
• Proposed Solution:
6849
2011-12
ADAAG 4.1.3(5)
CSAS 1007.2.1
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Nosings
Project Year:

Funding source:

Project:
504.5
80 LF $20 $1,600

0.75" unbeveled
PCODE EC01 Stair nosings project more than 1-1/2" past face of riser and/or are not beveled on underside 60° min.
from horizontal.

Modify stair nosings.
• As-Built Description:
• Proposed Solution:
• As-Built:
6853
2011-12
ADAAG 4.9.3
CSAS 1133B.4.5.2
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $1,600.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4384, Packet Page 4589 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
129-0-1
Osio Rodriquez Adobe Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 380 Alvarado St. CIP - General Fund
Total Costs for Part: Exterior $1,600.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4385, Packet Page 4590 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-1
Vasquez Adobe Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
1 POT from Acc. Parking to Recreation and Community Svcs. Dept.

Curb Ramp
Project Year:

Funding source:

Project:
705.1
PCODE EH07AREF REF
Detectable warning not provided where pedestrian
crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) at regular curb ramp.
• As-Built Description:
• Proposed Solution:
5737
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
REF

6.0% - 6.3%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
7046
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Recreation and Community Svcs. Dept. Entrance
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
30" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5739
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
42" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
5740
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Staff Lobby Offices (Staff Only)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4386, Packet Page 4591 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-1
Vasquez Adobe Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
Gate
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Door width + 0"
PCODE ID23NT Front approach: At pull side, gate does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide alternate hinges to allow door swing in
both direction at single office.
• As-Built Description:
• Proposed Solution:
• As-Built:
5741
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Office Connecting to Patio (Staff Only)
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $250 $250

0.5" threshold
PCODE ID02 Existing threshold at door is 3/4" high or less but without a beveled edge on both sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
5744
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Conference Room (Staff Only)
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $250 $250

0.5" threshold
PCODE ID02 Existing threshold at door is 3/4" high or less but without a beveled edge on both sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
5745
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Copy Room (Staff Only)
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
28" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5748
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4387, Packet Page 4592 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-1
Vasquez Adobe Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
2 JOB $75 $150
Not in line with traffic flow
PCODE EF04 Walk: Grating has grid openings greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
5751
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
405.2
1 JOB $3,400 $3,400

11.2%
PCODE EB02 Slope greater than 1:12 (8.3%).

Demolish existing and provide new restroom ramp
with handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
5750
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
8 Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
41" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
5758
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5757
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 48" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5764
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4388, Packet Page 4593 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-1
Vasquez Adobe Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
Project Year:

Funding source:

Project:
609.3
1 JOB $500 $500

1.75" to wall
PCODE WB07E Grab bar clearance not 1-1/2" from wall.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
5765
2011-12
ADAAG 4.26.2
CSAS 1115B.7.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
2 REF
TPD: 8" above SGB;
SCD: 7" above RGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
5759
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400
Knee space: 25.5" high
PCODE WD04 Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5761
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
First aid kit: 9" protrusion at 53" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5762
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
REF
First aid: 61" AFF
PCODE IE01REF Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
5763
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4389, Packet Page 4594 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-1
Vasquez Adobe Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
29" in front of WC
PCODE WB03NT Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5756
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $15,815.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4390, Packet Page 4595 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-2
Vasquez Adobe Building Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
1 Interior Stair to Second Floor
Elevator
Project Year:

Funding source:

Project:

PCODE IK01 1 JOB ? $200,000 Elevator not provided in multistory building.

Provide new elevator or relocate city services and
programs on upper level to accessible area.
• As-Built Description:
• Proposed Solution:
5727
2011-12
ADAAG 4.1.3(5)
CSAS 1007.2.1
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Stairs
Project Year:

Funding source:

Project:
504.2
54 JOB $75 $4,050
10" tread
PCODE EC06 Stair tread width less than 11", measured
horizontally from nosing to nosing.

Rebuild stair as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5731
2011-12
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Staff Offices
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
7 JOB $2,600 $18,200
22" - 27.5" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5734
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 1
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
5732
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Second Floor $252,250.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4391, Packet Page 4596 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
134-1-2
Vasquez Adobe Building Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 546 Dutra St. CIP - General Fund
Total Costs for Part: Interior $268,065.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4392, Packet Page 4597 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
1 POT from Site Entry at Washington Street to Accessible Parking Curb Ramp
Project Year:

Funding source:

Project:
406.1
1 JOB $2,500 $2,500

8.5%
PCODE EH02A Slope greater than 1:12 (8.3%).

Demolish existing and provide new curb ramp.
• As-Built Description:
• Proposed Solution:
• As-Built:
3675
2011-12
ADAAG 4.7.2
CSAS 1127B.5.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
705.1
PCODE EH07A 1 JOB $250 $250
Detectable warning not provided where pedestrian
crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) at east curb ramp.
• As-Built Description:
• Proposed Solution:
3674
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
705.1
PCODE EH07ANT 1 JOB $250 $250
Detectable warning not completely provided where
pedestrian crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) covering entire width of west curb
ramp.
• As-Built Description:
• Proposed Solution:
3673
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
1 JOB $160 $160

1.5"
PCODE EF04 Walk: Grating has grid openings greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
3676
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Accessible Parking Spaces
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 123 LF $27 $3,321 36" wide band of truncated domes not provided at walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
3682
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4393, Packet Page 4598 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
PCODE EF04 1 JOB $160 $160
Walk: Grating has grid openings greater than 1/2"
along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
3683
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.2; 302.3
PCODE EF04REF 6 REF
Throughout parking area: Grating has grid openings
greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
3678
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
980 SF $12 $11,760

2.4% - 3.6%
PCODE EA05 Accessible parking space has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
3677
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:

PCODE EA04D 4 JOB $100 $400
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
3679
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
3 POT from Acc. Parking to Entrance
Changes in Level
Project Year:

Funding source:

Project:
403.4
8 SF $21 $168

0.5" - 0.75" change in level
PCODE EF03 Adjacent to tree: Pavement dislocation creates abrupt change in level exceeding 1/2" in accessible
route.

Remove, replace or repair area of pavement
sufficient to correct abrupt change in level.
• As-Built Description:
• Proposed Solution:
• As-Built:
3684
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Drop-off Area and Curb Ramp
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4394, Packet Page 4599 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Access Aisle
Project Year:

Funding source:

Project:
503.3
PCODE EA08 1 JOB $600 $600
Aisle at passenger drop-off, adjacent to the vehicle
pull-up space is not 60"x 240" and/or slopes more
than 1/4":12" (2%).

Modify passenger drop-off.
• As-Built Description:
• Proposed Solution:
3685
2011-12
ADAAG 4.6.6
CSAS 1131B.2.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Curb Ramp
Project Year:

Funding source:

Project:
406.2
1 JOB $100 $100

0.5" - 1"
PCODE EH02D Transition from curb ramp to gutter does not have a smooth transition.

Grind lip.
• As-Built Description:
• Proposed Solution:
• As-Built:
3688
2011-12
ADAAG 4.7.2
CSAS 1127B.5.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
705.1
PCODE EH07A 1 JOB $250 $250
Detectable warning not provided where pedestrian
crosses vehicular area.

Provide detectable warning surface (i.e. in-line
truncated domes) at regular curb ramp.
• As-Built Description:
• Proposed Solution:
3687
2011-12
ADAAG 4.7.7
CSAS 1127B.5.7
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
PCODE EF04REF REF
Walk: Grating has grid openings greater than 1/2"
along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
3686
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Exit Ramp at Del Monte Avenue
Change in Direction
Project Year:

Funding source:

Project:
405.7.4
35 SF $45 $1,575
64"
PCODE EB08 Landing at change of direction not at least
60"x60" (CA only: 72"x width of ramp runs).

Modify ramp bottom landing to 72" length.
• As-Built Description:
• Proposed Solution:
• As-Built:
3691
2011-12
ADAAG 4.8.4(3)
CSAS 1133B.5.4
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4395, Packet Page 4600 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Door
Project Year:

Funding source:

Project:
404.2.4
50 SF $40 $2,000

2.4% - 2.6%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
3689
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
405.2
120 SF $100 $12,000

9.6%-10%
PCODE EB02 Slope greater than 1:12 (8.3%) at lower ramp.

Demolish existing and provide new ramp with
handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
3694
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Exit Ramp at Del Monte Avenue
Ramp
Project Year:

Funding source:

Project:
405.1
48 LF $75 $3,600

6.1% - 8.6%
PCODE EB03 Slope not steep but greater than 1:20 (5.0 %) without handrails.

Provide handrails for ramp.
• As-Built Description:
• Proposed Solution:
• As-Built:
3697
2011-12
ADAAG 4.8.1
CSAS 1133B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
405.2
24 SF $100 $2,400

8.6%
PCODE EB02 Slope greater than 1:12 (8.3%) at lower portion of ramp.

Demolish existing lower portion of ramp and
provide new ramp with handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
3698
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
405.7.1
42 SF $100 $4,200

2.8% - 3.2%
PCODE EB05A Level 2% max. top landing for ramp not provided.

Re-grade top landing with slopes no greater than
2%
• As-Built Description:
• Proposed Solution:
• As-Built:
3699
2011-12
ADAAG 4.8.4
CSAS 1133B.5.4.1
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $45,694.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4396, Packet Page 4601 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Total Costs for Part: Exterior $45,694.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4397, Packet Page 4602 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
2 Elevator Lobby and Stairway
Elevator
Project Year:

Funding source:

Project:

PCODE IK11D 1 SET $50 $50
California Braille (1/10" dot spacing) not provided
at control panel.

Provide compliant floor numbering on elevator
control panel (each floor).
• As-Built Description:
• Proposed Solution:
3438
2011-12 CSAS 1116B.1.14
Severity 3
Priority 4
General Fund
City ADA Transition Plan Upgrade
Vending Machine
Project Year:

Funding source:

Project:
308.2.1
REF
53" - 54" AFF
PCODE IL02 Vending machine coin slot or dispensing outlet, more than 48" above the floor.

Advise vendor/leasing company to provide
accessible vending machine with highest operable
part at 48" max.
• As-Built Description:
• Proposed Solution:
• As-Built:
3434
2011-12
ADAAG 4.2.5
CSAS 1126B
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Central Corridor
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 26.5" high x
16" deep
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide dining table with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
3450
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
3 JOB $100 $300
F.E. Cabinet: 6.5" protrusion at 33" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3445
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4398, Packet Page 4603 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
REF
F.E. Cabinet: 49" AFF
PCODE IE01REF Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3446
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Men's Restroom at West Corridor
Accessories
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3459
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
43" from face of door to trash bin
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3454
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 50" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3458
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 40.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3457
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4399, Packet Page 4604 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Locker Facilities
Project Year:

Funding source:

Project:
1 JOB $750 $750
19" x 56" non-fixed bench
PCODE GG03 No section of bench provided adjacent to
designated accessible locker, measuring 24” deep,
48” wide, and 18” high, and fixed to a wall along
the longer dimension.

Provide a new bench, fixed to a wall along the
longer dimension, close to the accessible locker.
• As-Built Description:
• Proposed Solution:
• As-Built:
3462
2011-12
ADAAG 4.35.4
CSAS 1117B.8
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE GG04 1 JOB $750 $750
Accessible locker(s) in dressing room not provided
(1% of lockers; not less than one).

Provide new locker(s) with accessible locking
hardware that is operable with one hand and does
not require grasping, pinching or twisting.
• As-Built Description:
• Proposed Solution:
3461
2011-12
ADAAG 4.1.3(12)(a)
CSAS 1115B.8.5
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
5 Women's Restroom at West Corridor
Accessories
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3470
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
43" from face of door to trash bin
PCODE ID23AREF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3464
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $2,600 $2,600
52" from stall door to counter
PCODE ID27B Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
7047
2011-12 CSAS 11B-26A(c)
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4400, Packet Page 4605 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 50" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3468
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 40.75" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3469
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Locker Facilities
Project Year:

Funding source:

Project:
1 JOB $750 $750
19" x 56" non-fixed bench
PCODE GG03 No section of bench provided adjacent to
designated accessible locker, measuring 24” deep,
48” wide, and 18” high, and fixed to a wall along
the longer dimension.

Provide a new bench, fixed to a wall along the
longer dimension, close to the accessible locker.
• As-Built Description:
• Proposed Solution:
• As-Built:
3472
2011-12
ADAAG 4.35.4
CSAS 1117B.8
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE GG04 1 JOB $750 $750
Accessible locker(s) in dressing room not provided
(1% of lockers; not less than one).

Provide new locker(s) with accessible locking
hardware that is operable with one hand and does
not require grasping, pinching or twisting.
• As-Built Description:
• Proposed Solution:
3471
2011-12
ADAAG 4.1.3(12)(a)
CSAS 1115B.8.5
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
7 Studio 1
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4401, Packet Page 4606 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
57" from face of door to F.E. cabinet at
corridor
PCODE ID23ANT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24") due to fire extinguisher cabinet.

Relocate fire extinguisher cabinet.
• As-Built Description:
• Proposed Solution:
• As-Built:
3478
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
1 JOB $350 $350
Door width + 5"
PCODE ID24ANT Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer) due to cubbies.

Modify existing cubbies to provide required 12" at
latch side of door.
• As-Built Description:
• Proposed Solution:
• As-Built:
3481
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
F.E. Cabinet: 7" protrusion at 33" AFF
PCODE EG04 Fire extinguisher cabinet inside studio I protrudes more than 4" from wall, when bottom of object
more than 27" or less than 80" above finished floor.

Relocate existing fire extinguisher cabinet. Patch
existing surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3483
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
307.2
REF
F.E. Cabinet: 7" protrusion at 33" AFF
PCODE EG04REF Fire extinguisher cabinet at corridor protrudes more than 4" from wall, when bottom of object more than
27" or less than 80" above finished floor.

Relocate existing fire extinguisher cabinet. Patch
existing surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3479
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $350 $350
AV station: 65" AFF
PCODE IE01NT At fire extinguisher cabinet, reach height to operable part exceeds 48" AFF.

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3484
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
8 Kid Zone
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4402, Packet Page 4607 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:

REF

5.75" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3497
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Knee space: 24" high
PCODE IN02NT Accessible fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide)
not provided."
Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
3498
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 2"
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3490
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
3495
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01ANT 1 JOB $35,000 $35,000 Multiple accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide accessible restroom with
one accessible stall, lavatory (and one urinal at
Men's).
• As-Built Description:
• Proposed Solution:
3496
2011-12
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4403, Packet Page 4608 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
34" o.c.

PCODE WB02A More than 18" from near side wall to centerline of water closet.

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
3493
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
9 Weight Training Center
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 2"
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3505
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
11 Cardio Fitness Center
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 2"
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3507
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
12 Gymnasium
Reach Range
Project Year:

Funding source:

Project:
308.2.1
3 JOB $100 $300
F.E. Cabinet: 56" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3513
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
13 Women's Restroom at East Corridor
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4404, Packet Page 4609 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:

REF

5.75" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3521
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 49.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3518
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3519
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not
completely self closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
3522
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
14 Family Dressing Room
Baby Changing Station
Project Year:

Funding source:

Project:
306.1
REF
Top: 36" high
PCODE IN02REF Baby changing station (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide) not
provided."
Modify baby changing station mounting height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3529
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4405, Packet Page 4610 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
2 JOB $2,600 $5,200
Door width + 2" - 11.5"
PCODE ID23B Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3526
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Locker Facilities
Project Year:

Funding source:

Project:

PCODE GG03 1 JOB $750 $750
No section of bench provided adjacent to
designated accessible locker, measuring 24” deep,
48” wide, and 18” high, and fixed to a wall along
the longer dimension.

Provide a new bench, fixed to a wall along the
longer dimension, close to the accessible locker.
• As-Built Description:
• Proposed Solution:
3527
2011-12
ADAAG 4.35.4
CSAS 1117B.8
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
BCS: 58" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3528
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
15 Men's Locker and Shower Room
Accessories
Project Year:

Funding source:

Project:

REF

5.75" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3548
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4406, Packet Page 4611 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Top: 36" high
PCODE IN02NT Baby changing station (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide) not
provided."
Remount baby changing station at accessible
height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3538
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
58" from face of door to urinal partition
wall
PCODE ID23NT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Shorten urinal partition to provide required
maneuvering space.
• As-Built Description:
• Proposed Solution:
• As-Built:
3541
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Door width + 8"
PCODE ID24NT Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Remove latch.
• As-Built Description:
• Proposed Solution:
• As-Built:
3534
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 51.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3547
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3546
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4407, Packet Page 4612 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:
609.3
REF
SCD: 4" above RGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
3550
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Locker Facilities
Project Year:

Funding source:

Project:

PCODE GG03 1 JOB $750 $750
No section of bench provided adjacent to
designated accessible locker, measuring 24” deep,
48” wide, and 18” high, and fixed to a wall along
the longer dimension.

Provide a new bench, fixed to a wall along the
longer dimension, close to the accessible locker.
• As-Built Description:
• Proposed Solution:
3539
2011-12
ADAAG 4.35.4
CSAS 1117B.8
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
6 LF $100 $600
EHD: 9" protrusion at 50" - 70" AFF
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
3551
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Fire extinguisher cabinet: 56" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3535
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
58" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3537
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4408, Packet Page 4613 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Shower
Project Year:

Funding source:

Project:
608.2
1 JOB $3,300 $3,300
41" x 44"
PCODE WF02 Shower less than 36" x 36" or 60" x 30" (CA only:
60"x 30").

Enlarge shower to CA dimensions.
• As-Built Description:
• Proposed Solution:
• As-Built:
3556
2011-12
ADAAG 4.21.2
CSAS 1115B.4.4.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
608.6
PCODE WF05 1 JOB $500 $500
Shower spray unit with hose at least 60" long that
can be used fixed and hand-held is not provided
(Exception: Where vandalism is a consideration, a
fixed shower head mounted at 48" height is
allowed).

Provide an accessible shower spray unit with hose
(60" minimum length).
• As-Built Description:
• Proposed Solution:
3555
2011-12
ADAAG 4.21.6
CSAS 1115B.4.4.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
3542
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

18.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3545
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
16 Natatorium
Door
Project Year:

Funding source:

Project:
404.2.4
50 SF $40 $2,000

3.0%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
3559
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4409, Packet Page 4614 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Lifts
Project Year:

Funding source:

Project:
203.11
PCODE IO01 1 REF
Wheelchair access to water slide not provided
Access not required per ADA 2010 . 203.11
• As-Built Description:
• Proposed Solution:
3561
2011-12
ADAAG 4.11.1; 4.11.2
CSAS 1116B.2
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
F.E. Cabinet: 6" protrusion at 62" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3575
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
307.2
4 JOB $100 $400
Pool cover: 26" protrusion at 54" AFF
PCODE EG04A Wall mounted pool cover at northeast end near exit to Del Monte Avenue protrudes more than 4" from
wall, when bottom of object more than 27" or less
than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
3572
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
4 JOB $100 $400
F.E. cabinet: 63" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Remount fire extinguisher cabinet at accessible
height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3569
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Shower
Project Year:

Funding source:

Project:
608.5
1 JOB $800 $800
49" AFF
PCODE WF12 Controls not located at 40" max. height or not within a range of no less than 19" and no more than
27" from the seat wall.

Provide new, or relocate, shower controls.
• As-Built Description:
• Proposed Solution:
• As-Built:
3576
2011-12
ADAAG 4.27.3
CSAS 1115B.4.4.4.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4410, Packet Page 4615 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Stairway
Project Year:

Funding source:

Project:

PCODE II02D 78 LF $36 $2,808 Stair does not have closed risers.

Modify stair to have closed risers.
• As-Built Description:
• Proposed Solution:
3562
2011-12
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Swimming Pool
Project Year:

Funding source:

Project:

PCODE GJ03 270 LF $73 $19,710 Pool edges, ramps and stairs are not identified by texture and/or color change.

Provide alternating color bands.
• As-Built Description:
• Proposed Solution:
3560
2011-12
ADAAG pending
Severity 3
Priority 2
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE GJ03 70 LF $73 $5,110 Pool edges, ramps and stairs are not identified by texture and/or color change.

Provide alternating color bands.
• As-Built Description:
• Proposed Solution:
3566
2011-12
ADAAG pending
Severity 3
Priority 2
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $250 $250
58" AFF
PCODE IB02NT Emergency telephone mounting height more than 48" to highest operable part of phone.

Lower telephone enclosure and phone.
• As-Built Description:
• Proposed Solution:
• As-Built:
3581
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $110 $110
12"
PCODE IB07A Emergency telephone cord length less than 29".

Provide new telephone cord with minimum 29"
length.
• As-Built Description:
• Proposed Solution:
• As-Built:
3582
2011-12
ADAAG 4.31.8
CSAS 1117B.2.11
Severity 1
Priority 3 General Fund
City ADA Transition Plan Upgrade
17 North Side Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4411, Packet Page 4616 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
41" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3593
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF

5.75" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3594
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 2"
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3592
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 49.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3595
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3596
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4412, Packet Page 4617 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $900 $900
14" o.c.

PCODE WD01A Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Relocate existing lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
3591
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

19.75" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3597
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
18 South Side Unisex Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
41" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3608
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF

5.75" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3609
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4413, Packet Page 4618 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 2"
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3604
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 49.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3611
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3612
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $900 $900
14" o.c.

PCODE WD01A Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Relocate existing lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
3607
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4414, Packet Page 4619 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

19.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3610
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
19 Women's Locker and Shower Room
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
40" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3630
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
TPD: 5.75" protrusion
FND: 4" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3629
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Baby Changing Station
Project Year:

Funding source:

Project:
306.1
PCODE IN02REF REF
Baby changing station (top 28" to 34" high; knee
space at least 27" high x 19" deep x 30" wide) not
provided."
Remount baby changing station at accessible
height.
• As-Built Description:
• Proposed Solution:
3621
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4415, Packet Page 4620 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 51" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3627
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3628
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5
1 JOB $260 $260
34" o.c.

PCODE WB07C Grab bars not at 33" to 36" from floor (CA only:
33" from floor if no tank toilet).

Relocate accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
3631
2011-12
ADAAG 4.16.4
CSAS 1115B.4.1.3.1 & 2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Locker Facilities
Project Year:

Funding source:

Project:
1 JOB $750 $750
15" deep
PCODE GG03 No section of bench provided adjacent to
designated accessible locker, measuring 24” deep,
48” wide, and 18” high, and fixed to a wall along
the longer dimension.

Provide a new bench, fixed to a wall along the
longer dimension, close to the accessible locker.
• As-Built Description:
• Proposed Solution:
• As-Built:
3618
2011-12
ADAAG 4.35.4
CSAS 1117B.8
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
FTD: 5.5" protrusion at 30" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3622
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4416, Packet Page 4621 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
BCS: 59" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3620
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Semi-Ambulant Stall
Project Year:

Funding source:

Project:
213.3.1
PCODE WB06B 1 JOB $400 $400
Semi-ambulant stall in restroom not compliant (one
required where 6 or more exist).

Provide grab bars in otherwise compliant stall.
• As-Built Description:
• Proposed Solution:
3625
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Shower
Project Year:

Funding source:

Project:
608.2
2 JOB $3,300 $6,600
43" x 48"
PCODE WF02 Shower less than 36" x 36" or 60" x 30" (CA only:
60"x 30").

Enlarge shower to CA dimensions.
• As-Built Description:
• Proposed Solution:
• As-Built:
3632
2011-12
ADAAG 4.21.2
CSAS 1115B.4.4.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
3626
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $126,848.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4417, Packet Page 4622 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
2 Studio 2
Telephone
Project Year:

Funding source:

Project:

PCODE IB01REF 2 REF
Telephone: Clear floor space, 30" wide x 48" out
from wall, not provided.

Relocate emergency phones and remount them at
accessible height.
• As-Built Description:
• Proposed Solution:
3639
2011-12
ADAAG 4.31.2
CSAS 1117B.2.2
Severity 2
Priority 3 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
704.2.2
2 JOB $100 $200
Emergency phone: 56" and 66"
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower phone to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3638
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Unisex Restroom
Accessories
Project Year:

Funding source:

Project:

REF

5.75" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3646
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
53" from face of door to PTD
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3648
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4418, Packet Page 4623 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 48" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3647
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
PCODE WD04A 1 JOB $1,500 $1,500 Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
3644
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Sports Center Manager Offices
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $200 $200
47" from face of door to counter
PCODE ID23ANT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3651
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
Top: 44" high
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
3652
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Kitchen
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4419, Packet Page 4624 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Corridor
Project Year:

Funding source:

Project:
1 JOB $50 $50
35" between metal cabinet and counter
PCODE IH03A Corridor, for occupant load less than 10, less than 36" wide.

Remove or relocate furniture and storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3656
2011-12
ADAAG 4.3.3
CSAS 1133B.3.1
Severity 4
Priority 4 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
Door width + 1" to metal cabinet
PCODE ID24A Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3662
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
PTD: 10" protrusion at 48" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3659
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
64" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3660
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Restroom at Kitchen
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
46" from back wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3667
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4420, Packet Page 4625 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3668
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
41" from face of door to metal cabinet
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3665
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 50" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3669
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 38" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3670
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
1 JOB $5,000 $5,000

47.5" to wall
PCODE WB03ANT CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Relocate fixture to provide at least 48" in front of
water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
3671
2011-12 CSAS 1115B.3.2.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Second Floor $8,465.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4421, Packet Page 4626 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Total Costs for Part: Interior $135,313.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4422, Packet Page 4627 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-0-1
City Offices Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
1 POT from Pacific to Main Entrance
Changes in Level
Project Year:

Funding source:

Project:
403.4
REF

0.5" change in level
PCODE EF03AREF Walk: Pavement dislocation creates vertical change in level between 1/4" and 1/2" in accessible route.

Grind or fill pavement dislocation to create beveled
transition.
• As-Built Description:
• Proposed Solution:
• As-Built:
5525
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.4
REF

0.75"
PCODE EF03AREF Walk: Pavement dislocation creates vertical change in level between 1/4" and 1/2" in accessible route.

Grind or fill pavement dislocation to create beveled
transition.
• As-Built Description:
• Proposed Solution:
• As-Built:
5527
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 125 LF $27 $3,375 36" wide band of truncated domes not provided at walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
5526
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
120 SF $25 $3,000
3% - 3.2%
PCODE EF07 At beginning portion of walkway: Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5524
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.3
30 SF $25 $750

2.3% - 2.9%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5528
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Accessible Parking
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4423, Packet Page 4628 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-0-1
City Offices Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09NT 4 LF $27 $108
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Detectable warning should be at bottom landing of
ramp.
• As-Built Description:
• Proposed Solution:
5530
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
1 JOB $160 $160

0.75"
PCODE EF04 At ramp to adjacent building walk: : Grating has grid openings greater than 1/2" along the line of
traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
5534
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:

PCODE EA04DNT 1 JOB $100 $100
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
5531
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
405.2
25 SF $100 $2,500

14.3%
PCODE EB02 At ramp to adjacent building: Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
5533
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.3
PCODE EF07 30 SF $25 $750
Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
5529
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On Site $10,743.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4424, Packet Page 4629 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-0-1
City Offices Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Total Costs for Part: Exterior $10,743.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4425, Packet Page 4630 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
1 Main Entrance and Lobby
Brochure Bins
Project Year:

Funding source:

Project:
1 JOB $100 $100
64" AFF
PCODE IN08 Information brochure bins mounted above
accessible height 48"
Relocate/remount bins at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5460
2011-12
ADAAG 4.2.5 & 6
CSAS 1118B.5
Severity 2
Priority 1 General Fund
City ADA Transition Plan Upgrade
Door
Project Year:

Funding source:

Project:
1 JOB $100 $100
5"
PCODE ID06 At push side of door on accessible route, bottom 10" does not have a smooth, uninterrupted surface
(required in CA only).

Provide 10" min. "kick plate" covering width of
door when altering area.
• As-Built Description:
• Proposed Solution:
• As-Built:
5457
2011-12 CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
4 JOB $100 $400
counter:12" protrusion at 33" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5458
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Corridor to Finance (Staff Only)
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

6.6%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
5466
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Finance Conference Room (Staff Only)
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4426, Packet Page 4631 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01E REF
No portable assistive listening system provided for
small meeting room.

Share existing portable assistive listening system
from other facility.
• As-Built Description:
• Proposed Solution:
5469
2011-12
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Restroom in Finance (Staff Only)
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
27" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5470
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Entry Door
Project Year:

Funding source:

Project:

PCODE WC03CREF REF
CA only: Restroom entry / exit door: 60" square
clear space not provided at door swing side.

Provide automatic door.
• As-Built Description:
• Proposed Solution:
5474
2011-12 CSAS 1115B.3.1.1
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
5471
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:

REF
8" to lav
PCODE WB01REF CA only: Less than 32" from side of water closet to far side of stall wall or 28" to adjacent fixture.

Relocate water closet. Remodel restroom as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5472
2011-12 CSAS 1115B.4.1.1
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4427, Packet Page 4632 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:

REF
34" in front of WC
PCODE WB03AREF CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Remodel restroom to provide at least 48" in front of
water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
5473
2011-12 CSAS 1115B.3.2.1
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
6 Employee Break Room (Staff Only)
Door Swing
Project Year:

Funding source:

Project:
404.2.4
PCODE ID23A 1 JOB $50 $50
Front approach: At pull side, door does not have
clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
5478
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
33" from face of door to vending at
fridge
PCODE ID23NT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Relocate vending machine.
• As-Built Description:
• Proposed Solution:
• As-Built:
5479
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 HR Conference Room
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01E REF
No portable assistive listening system provided for
small meeting room.

Share existing portable assistive listening system
from other facility.
• As-Built Description:
• Proposed Solution:
5481
2011-12
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
16" deep
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5482
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4428, Packet Page 4633 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
8 HR Offices and Restroom (Staff Only)
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
27" clear opening width
PCODE ID01REF At restroom: Door on accessible route has less than 32" clear opening width when 90° open (CA only:...
or has leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5489
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Counter: 12" protrusion at 44" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5483
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
5488
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
9 ISD Offices Corridor and Restroom (Staff Only)
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
27" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5496
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4429, Packet Page 4634 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
5495
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
10 Information Resources Training Room (Staff Only)
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
24" wide
PCODE IN02NT At PC station: Accessible fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19"
deep x 30" wide) not provided."
Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
5497
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
11 IT Lab (Staff Only)
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01E REF
Adjacent conference room: No portable assistive
listening system provided for small meeting room.

Share existing portable assistive listening system
from other facility.
• As-Built Description:
• Proposed Solution:
5505
2011-12
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Top: 36.5" high
PCODE IN02 At workbench: Accessible fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19"
deep x 30" wide) not provided.

Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
5501
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4430, Packet Page 4635 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
Door width + 5" to wall
PCODE ID24B At exit door front approach: At push side, door does not have clear and level maneuvering space
measuring door width x 48" (door width plus 12" if
door has both, latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5504
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
12 Orca Conference Room (Staff Only)
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01E REF
No portable assistive listening system provided for
small meeting room.

Share existing portable assistive listening system
from other facility.
• As-Built Description:
• Proposed Solution:
5509
2011-12
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
4 LF $100 $400
TV: 8" protrusion at 53"
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5510
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
13 Women's Restroom Public
Accessories
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5514
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
14 Men's Restroom Public
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4431, Packet Page 4636 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5520
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 53.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5518
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $200 $200
LAV: 26" protrusion at 31" AFF
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing or wing wall to
mark area of low clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5522
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

18.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5519
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On Site $102,810.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4432, Packet Page 4637 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
139-1-1
City Offices Part: Interior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Pacific St. CIP - General Fund
Total Costs for Part: Interior $102,810.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4433, Packet Page 4638 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-0-1
Monterey Youth Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
1 POT from Sidewalk to Front Entrance to Youth Center
Changes in Level
Project Year:

Funding source:

Project:
403.4
15 SF $21 $315

0.75" change in level
PCODE EF03A Expansion joint: Pavement dislocation creates vertical change in level between 1/4" and 1/2" in
accessible route.

Fill expansion joint to create beveled transition.
• As-Built Description:
• Proposed Solution:
• As-Built:
5837
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 65 LF $27 $1,755 36" wide band of truncated domes not provided at walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
5838
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
1 JOB $160 $160

0.75"
PCODE EF04 Walk: Grating has grid openings greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
5836
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
70 SF $25 $1,750

4.2% - 7.0%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5834
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
40 SF $25 $1,000

5.3% - 5.9%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
5835
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Accessible Parking for Youth Center
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4434, Packet Page 4639 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-0-1
Monterey Youth Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
54 SF $12 $648

3.6% - 6.0%
PCODE EA05 Portion of accessible parking space along walkway has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
5843
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:
1 JOB $200 $200
8'-9" wide
PCODE EA02A Accessible parking space smaller than 8' wide (CA only: 9' x 18').

Modify parking space(s) to create accessible space.
• As-Built Description:
• Proposed Solution:
• As-Built:
5842
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
502.3
PCODE EA02B 1 JOB $200 $200
Accessible parking space does not have 5' wide
access aisle; 8' wide for van accessible aisle (CA
only: aisle spaces need to be 18' in length).

Modify parking aisle(s) to create accessible space
by restriping.
• As-Built Description:
• Proposed Solution:
5839
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE EA04DREF REF
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min. high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
5840
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
3 POT from Preschool to Play Area
Ramps
Project Year:

Funding source:

Project:
303.4
PCODE EB01A 30 SF $100 $3,000 Ramp needed to provide disabled access at steps or change of level along path of travel.

Provide new concrete ramp with handrails [slope
more than 1:20 (5.0%) needed].
• As-Built Description:
• Proposed Solution:
5844
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 POT from Parking to Barbecue Area
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4435, Packet Page 4640 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-0-1
Monterey Youth Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Accessible Route
Project Year:

Funding source:

Project:
206.1
PCODE EF13 400 LF $45 $18,000 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

Provide new 48" wide walk / sidewalk to BBQ area.
• As-Built Description:
• Proposed Solution:
5845
2011-12
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Picnic Table
Project Year:

Funding source:

Project:
902.2
1 JOB $450 $450
10" deep
PCODE NH11A Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5846
2011-12
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Dance Studio and Restroom
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

5.1%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
5847
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF

25.5" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5856
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Pair
Project Year:

Funding source:

Project:
1 JOB $1,500 $1,500

27.5" clear opening width
PCODE ID08A Pair of doors on accessible route has less than 32" clear opening width with one leaf open 90°.

Provide new door leaves, unequal in width, to
existing frame for pair of doors.
• As-Built Description:
• Proposed Solution:
• As-Built:
5851
2011-12
ADAAG 4.13.4
CSAS 1133B.2.3.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4436, Packet Page 4641 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-0-1
Monterey Youth Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Door Threshold
Project Year:

Funding source:

Project:
90 SF $100 $9,000
7"
PCODE ID02B Door inaccessible due to threshold or step at door more than 6" high.

Provide ramp including handrails and compliant
landings, matching floor level inside door (+/-1/4").
• As-Built Description:
• Proposed Solution:
• As-Built:
5853
2011-12
ADAAG 4.8.5
CSAS 1133B.2.4.1
Severity 4
Priority 2 General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
5855
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF

29.5" in front of water closet
PCODE WB03REF Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5857
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 1
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:

REF
17" between water closet and lavatory
PCODE WB09REF In single occupancy restroom less than 18" from centerline of water closet to another fixture (CA
only: 28" from edge of water closet to edge of
another fixture).

Provide new, accessible fixture. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5858
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 2 General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $68,978.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4437, Packet Page 4642 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-0-1
Monterey Youth Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Total Costs for Part: Exterior $68,978.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4438, Packet Page 4643 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
1 Lobby and Entrance
Desk
Project Year:

Funding source:

Project:
306.1
REF
43" to pc
PCODE IN02REF Accessible fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide)
not provided."
Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
5777
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
43" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
5776
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Conference Room
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01E REF
No portable assistive listening system provided for
small meeting room.

Share existing portable assistive listening system
from other facility.
• As-Built Description:
• Proposed Solution:
5780
2011-12
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Main Hall Auditorium
Open Risers
Project Year:

Funding source:

Project:
504.3
PCODE EC03 20 LF $36 $720
Movable stair does not have closed risers.

Modify stair to have closed risers
• As-Built Description:
• Proposed Solution:
5790
2011-12
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4439, Packet Page 4644 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Fire Extinguisher: 60" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
5786
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stages
Project Year:

Funding source:

Project:
1 JOB $25,000 $25,000
40" AFF
PCODE GC01A Stage, enclosed and unenclosed platform, backstage areas or orchestra pit not accessible.

Provide ramp or chair lift to raised platform.
• As-Built Description:
• Proposed Solution:
• As-Built:
5789
2011-12
ADAAG 4.33.5
CSAS 1104B.3.10
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
4 Teen Room
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
13" deep
PCODE IN02 Accessible fixed PC station (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide)
not provided.

Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
5799
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Pair
Project Year:

Funding source:

Project:
1 JOB $1,500 $1,500

29.5" clear opening width
PCODE ID08A Entrance door on accessible route has less than 32" clear opening width with one leaf open 90°.

Provide new door leaves, unequal in width, to
existing frame for pair of doors.
• As-Built Description:
• Proposed Solution:
• As-Built:
5795
2011-12
ADAAG 4.13.4
CSAS 1133B.2.3.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
22"
PCODE IN03 PC station: Accessible section min. 36" length and 36" max. height (in CA: 28" to 34" high) not
provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
5798
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 1
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4440, Packet Page 4645 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5811
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
49" from face of door to wall
PCODE ID23BNT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5803
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 14.5" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5808
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
5805
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4441, Packet Page 4646 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

19.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5807
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Men's Restroom
Accessories
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5821
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
56" from face of stall door to wall
PCODE ID23BNT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5816
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
56" from face of door
PCODE ID27B Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5815
2011-12
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4442, Packet Page 4647 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 16" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5820
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
5818
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 Kitchen
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" clear opening width to main hall
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5825
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
8 Preschool and Preschool Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5829
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4443, Packet Page 4648 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Water Closet (Kindergarten)
Project Year:

Funding source:

Project:

PCODE WK01A 1 JOB $4,500 $4,500 Centerline of water closet not 12" from near side wall.

Provide new or relocate accessible water closet.
• As-Built Description:
• Proposed Solution:
5833
2011-12
ADAAG 4.16.7(1)
CSAS Tbl. 1115B-1(K)
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE WK03A 1 JOB $300 $300
Grab bars not between 18" and 20" above floor (CA
only: Side grab bar not between 20" and 22" above
floor).

Relocate accessible grab bars.
• As-Built Description:
• Proposed Solution:
5832
2011-12
ADAAG 4.16.7(3)
CSAS Tbl. 1115B-1(K)
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $48,990.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4444, Packet Page 4649 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
140-1-1
Monterey Youth Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl St. CIP - General Fund
Total Costs for Part: Interior $48,990.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4445, Packet Page 4650 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
1 POT from Acc Parking to Entrance
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 24 LF $27 $648
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6055
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
56 SF $25 $1,400

4.5% - 6.2%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6056
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
40 SF $25 $1,000

6.3%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6057
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 POT from Sidewalk at Camino El Estero to Entrance
Walk
Project Year:

Funding source:

Project:
403.3
32 SF $25 $800

10.0%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6058
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 POT from Parking to Restroom Building
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4446, Packet Page 4651 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Changes in Level
Project Year:

Funding source:

Project:
403.4
8 SF $21 $168

0.75" change in level
PCODE EF03A Walk: Pavement dislocation creates vertical change in level between 1/4" and 1/2" in accessible route.

Grind or fill pavement dislocation to create beveled
transition.
• As-Built Description:
• Proposed Solution:
• As-Built:
6063
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Drinking Fountain
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
6061
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
40 SF $45 $1,800
36" wide
PCODE EF08 Walk more than 36" but less than 48" wide
(required in CA only).

Enlarge width of walk to 48".
• As-Built Description:
• Proposed Solution:
• As-Built:
6060
2011-12 CSAS 1133B.7.1
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $475 $475

4.9% - 6.3%
PCODE EF09 Walk more than 200' long is less than 60" wide and does not have passing space (60"x60") at 200'
intervals.

Provide passing space (60"x60") every 200'.
• As-Built Description:
• Proposed Solution:
• As-Built:
6059
2011-12
ADAAG 4.3.4
CSAS 1133B.7.1
Severity 4
Priority 1 General Fund
City ADA Transition Plan Upgrade
4 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4447, Packet Page 4652 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
39" from face of door to LAV
PCODE ID23BNT Front approach: At pull side, stall door does not have clear and level maneuvering space measuring
door width plus 18" x 60" (CA only: exterior door
width plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6073
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75

4.5"
PCODE WB07I Toilet paper dispenser in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6076
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400

14.5" o.c.

PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6070
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400
Knee space: 24" high
PCODE WD04 Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6068
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4448, Packet Page 4653 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
REF
EHD: 10" protrusion at 43" AFF
PCODE EG04REF Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6066
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6072
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
19" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6075
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Men's Restroom
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
38" from face of door to LAV
PCODE ID23BNT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6087
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4449, Packet Page 4654 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
5"
PCODE WB07I Toilet paper dispenser in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6090
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.2
REF
15" o.c.

PCODE WD01REF Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6082
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400
Knee space: 24" high
PCODE WD04 Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6083
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
2 JOB $100 $200
EHD: 10" protrusion at 43" AFF
BCS: 19" protrusion at 36" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6081
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4450, Packet Page 4655 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6085
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Urinal
Project Year:

Funding source:

Project:
605.3
1 JOB $1,500 $1,500
31" wide 33" deep
PCODE WE04A 36" wide clearance in front of accessible urinal not provided when walls or partitions project more than
24" from the front edge of 30" x 48" clear space.

Provide 36" clear floor space in front of accessible
urinal. Remodel restroom as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6079
2011-12
ADAAG 4.18.3
CSAS 1115B.4.2.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $27,166.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4451, Packet Page 4656 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-0-1
Visitor Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Total Costs for Part: Exterior $27,166.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4452, Packet Page 4657 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-1-1
Visitor Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
1 Visitor Center Lobby
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Top: 43" high
No knee space
PCODE IN02 PC station (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide) not provided.

Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
6096
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

13.8%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6092
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE ID18NT 1 JOB $550 $550
Doorway opening (32" min. clear) is not provided.

Enlarge opening to 32" min.
• As-Built Description:
• Proposed Solution:
6094
2011-12
ADAAG 4.13.5
CSAS 11B-33(a)
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
65" to large touch screen
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6097
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Staff Restroom
Accessories
Project Year:

Funding source:

Project:

REF
6" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6100
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4453, Packet Page 4658 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-1-1
Visitor Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 48.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6098
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Turning Space
Project Year:

Funding source:

Project:
603.2.1
1 JOB $1,190 $1,190
Lavatory within clear space
PCODE WC01NT Wheelchair clearance: Clear space, floor to 27" high with a diameter of 60", not provided (space
56" x 63" acceptable).

Provide wheelchair clearance space in restroom.
• As-Built Description:
• Proposed Solution:
• As-Built:
6102
2011-12
ADAAG 4.22.3
CSAS 1115B.3.1
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
19" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6099
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $6,180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4454, Packet Page 4659 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
141-1-1
Visitor Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 401 Camino El Estero CIP - General Fund
Total Costs for Part: Interior $6,180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4455, Packet Page 4660 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-1
Cannery Row Parking Garage Office Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
1 Main Entrance / Lobby
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
PTD: 52" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6776
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $100.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4456, Packet Page 4661 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-2
Cannery Row Parking Garage Office Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
2 Offices Lobby and Ramp to Exit Door
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400
2"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6793
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Length
Project Year:

Funding source:

Project:
405.7.3
1 JOB $10,000 $10,000
55"
PCODE EB07NT Landing less than 60" long. (CA only: 72"x width of ramp runs at bottom landing).

Modify wall and area to provide bottom ramp
landing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6789
2011-12
ADAAG 4.8.4(2)
CSAS 1133B.5.4.2
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
42" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
6796
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Kitchen / Lounge
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
5" to refrigerator
PCODE ID23ANT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Change latch to hinge side.
• As-Built Description:
• Proposed Solution:
• As-Built:
6809
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Women's Restroom and Shower Room
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4457, Packet Page 4662 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-2
Cannery Row Parking Garage Office Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
47" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6824
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
6823
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 52" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6821
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340

39.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6822
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400
36" AFF
PCODE WD02 Lavatory: Fixture rim or counter height more than 34" above floor.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6813
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4458, Packet Page 4663 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-2
Cannery Row Parking Garage Office Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Shelf: 12" protrusion at 64" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6819
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Shower
Project Year:

Funding source:

Project:
1 JOB $500 $500
48" - 69"
PCODE WF05B CA only: Mounting height of shower spray bracket exceeds 48" max. or is more than 27" from rear
edge of folding seat.

Provide or remount shower spray bracket within
27" from rear edge of seat.
• As-Built Description:
• Proposed Solution:
• As-Built:
6825
2011-12 CSAS 1115B.4.4.5.3
Severity 1
Priority 5
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6816
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
22" o.c.

PCODE WB02A More than 18" from near side wall to centerline of water closet.

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6820
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Men's Restroom and Shower Room
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
48" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6838
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4459, Packet Page 4664 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-2
Cannery Row Parking Garage Office Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
Project Year:

Funding source:

Project:

REF
TPD: 5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6837
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 51" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6840
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 39" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6839
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400

35.25" AFF
PCODE WD02 Lavatory: Fixture rim or counter height more than 34" above floor.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6832
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Shelf: 13" protrusion at 65" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6842
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4460, Packet Page 4665 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-2
Cannery Row Parking Garage Office Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
Shower
Project Year:

Funding source:

Project:
1 JOB $500 $500
48" - 69"
PCODE WF05B CA only: Mounting height of shower spray bracket exceeds 48" max. or is more than 27" from rear
edge of folding seat.

Provide or remount shower spray bracket within
27" from rear edge of seat.
• As-Built Description:
• Proposed Solution:
• As-Built:
6833
2011-12 CSAS 1115B.4.4.5.3
Severity 1
Priority 5
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
20" o.c.

PCODE WB02A More than 18" from near side wall to centerline of water closet.

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6841
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
6836
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Second Floor $29,475.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4461, Packet Page 4666 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
143-1-2
Cannery Row Parking Garage Office Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 601 Wave St. CIP - General Fund
Total Costs for Part: Interior $29,575.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4462, Packet Page 4667 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
1 Reception Entrance / Lobby
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $250 $250

0.75"
PCODE ID02 Existing threshold at door is 3/4" high or less but without a beveled edge on both sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
6940
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150

43.5" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
6942
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Mail box: 65" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6937
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Teen Room / Computer Station
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
14" - 20" to railing
PCODE ID23BNT Front approach at exit door: At pull side, door does not have clear and level maneuvering space
measuring door width plus 18" x 60" (CA only:
exterior door width plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6945
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4463, Packet Page 4668 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Drinking Fountain
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
6948
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 24" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6949
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Main Hall
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
2 JOB $250 $500

0.75"
PCODE ID02 Existing threshold at door is 3/4" high or less but without a beveled edge on both sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
6956
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Vending Machine
Project Year:

Funding source:

Project:
308.2.1
REF
58" AFF
PCODE IL02 Vending machine coin slot or dispensing outlet, more than 48" above the floor.

Advise vendor/leasing company to provide
accessible vending machine with highest operable
part at 48" max.
• As-Built Description:
• Proposed Solution:
• As-Built:
6952
2011-12
ADAAG 4.2.5
CSAS 1126B
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Kitchen
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4464, Packet Page 4669 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
6" to cabinet
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6965
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $250 $250
Telephone: 65" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower telephone enclosure and phone.
• As-Built Description:
• Proposed Solution:
• As-Built:
6967
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Tray Pass-thru
Project Year:

Funding source:

Project:
1 JOB $3,300 $3,300
36" AFF
PCODE FB04 Food tray pass-thru at institutional cafeteria has lower edge higher than 34" above floor.

Remodel pass-thru and counter to be 34" max.
above floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
6963
2011-12
ADAAG 5.2
CSAS 1122B.4
Severity 4
Priority 2 General Fund
City ADA Transition Plan Upgrade
5 Corridor to Restrooms
Corridor
Project Year:

Funding source:

Project:
1 JOB $50 $50
38" - 41" to cubbies
PCODE IH03A Corridor, for occupant load less than 10, less than 36" wide.

Remove or relocate furniture and storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6969
2011-12
ADAAG 4.3.3
CSAS 1133B.3.1
Severity 4
Priority 3 General Fund
City ADA Transition Plan Upgrade
6 Preschool
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4465, Packet Page 4670 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
PCODE ID23BNT 1 JOB $1,500 $1,500 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Modify resilient surface to correct drop off adjacent
to door.
• As-Built Description:
• Proposed Solution:
6974
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 Preschool Patio
Fixed Bench
Project Year:

Funding source:

Project:
903.2
1 JOB $500 $500

4.7%
PCODE NO07 Clear floor or ground space (30" x 48") not
overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
• As-Built:
6977
2011-12
ADAAG 4.32.2
CSAS 1118B.4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
1 JOB $75 $75
Tree trunk: 51" AFF
PCODE EG01NT Overhead clearance less than 80" above finished floor.

Modify overhead clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6976
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
8 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
45" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6991
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4466, Packet Page 4671 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
43" to cubbies
PCODE ID23AREF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6981
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 16" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6994
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 48" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6995
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
REF
TPD: 9" above SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6993
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 24" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6984
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4467, Packet Page 4672 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Metal shelf: 77" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6987
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6988
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
19" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6992
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
9 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
42" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
7009
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4468, Packet Page 4673 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
2" to cubbies at latch side
PCODE ID23AREF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
7000
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 16" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
7011
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 40" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
7012
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
REF
TPD: 9" above SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
7013
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
7003
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4469, Packet Page 4674 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Metal shelf: 77" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Remove metal shelf.
• As-Built Description:
• Proposed Solution:
• As-Built:
7006
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
7007
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
17" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
7010
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $22,075.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4470, Packet Page 4675 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
144-1-1
Casanova/Oak Knoll Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona St. CIP - General Fund
Total Costs for Part: Interior $22,075.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4471, Packet Page 4676 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-1
Hilltop Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
1 Photography Room
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $100 $100
Phone: 57" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower phone to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6380
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Ceramic Room
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
PTD: 55" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6386
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $250 $250
Phone: 56" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower phone to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6383
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Classroom
Door
Project Year:

Funding source:

Project:
404.2.4
20 SF $40 $800

3.2%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6390
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
Phone: 56" AFF
PTD: 55" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6393
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4472, Packet Page 4677 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-1
Hilltop Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
4 Storage
Door
Project Year:

Funding source:

Project:
404.2.4
20 SF $40 $800

3.8%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6396
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 After School Room
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 25.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6405
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
2 LF $100 $200
EHD: 10" protrusion at 36" AFF
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6406
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $100 $100
Phone: 56" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower phone to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6404
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Exterior Patio Area
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4473, Packet Page 4678 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-1
Hilltop Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Fixed Bench
Project Year:

Funding source:

Project:
903.2
PCODE NO07 1 JOB $500 $500
Clear floor or ground space (30" x 48") not
overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
6409
2011-12
ADAAG 4.32.2
CSAS 1118B.4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Picnic Table
Project Year:

Funding source:

Project:
902.2
PCODE NH11A 1 JOB $450 $450
Knee clearance at minimums 27" high, 30" wide,
and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
6408
2011-12
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $5,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4474, Packet Page 4679 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
1 Main Hall
Reach Range
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
Phone: 62" AFF
Coat rack: 62" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6414
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Kitchen
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $100 $100
Phone: 66" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower phone to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6421
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Upper Activity Room No. 1
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

3.7%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6430
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Teen Room
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
16" deep
26" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Modify one existing table or desk to provide
accessible knee clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6438
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Main Lobby / Office
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4475, Packet Page 4680 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

5.5%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6440
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50

4.5" to file cabinet
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6445
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
42" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
6443
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 Work Room (Staff Only)
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600

24.5" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6448
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4476, Packet Page 4681 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
Door width + 14" to bench
PCODE ID23A Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
6449
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 5
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
24" wide
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6451
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
9 Small Conference Room
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01E REF
No portable assistive listening system provided for
small meeting room.

Share existing portable assistive listening system
from other facility.
• As-Built Description:
• Proposed Solution:
6454
2011-12
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
10 Preschool Unisex Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600

27.5" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6457
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4477, Packet Page 4682 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
36" long
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6465
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
30" long
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6466
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
SCD: 7" above GB
TPD: 3" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6468
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500

24.5"
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6463
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:

REF
16" to LAV
PCODE WB01AREF CA only: Less than 32" from side of water closet to far side of stall wall or 28" to adjacent fixture.

Remove adjacent fixture and provide new enclosure
at accessible water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6464
2011-12 CSAS 1115B.4.1.1
Severity 1
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4478, Packet Page 4683 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
16" o.c.

PCODE WB02 Less than 18" from near side wall to center line of water closet (proposed new ADAAG: 16"-18").

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6467
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $5,000 $5,000

47.5"
PCODE WB03A CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Remodel restroom to provide at least 48" in front of
water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6461
2011-12 CSAS 1115B.3.2.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
11 Preschool Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600

27.5" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6473
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
36" long
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6481
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
30" long
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6480
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4479, Packet Page 4684 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
TPD: 4.5" above GB
SCD: 7" above GB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6482
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 24.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6477
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:

REF
16"
PCODE WB01AREF CA only: Less than 32" from side of water closet to far side of stall wall or 28" to adjacent fixture.

Remove adjacent fixture and provide new enclosure
at accessible water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6478
2011-12 CSAS 1115B.4.1.1
Severity 1
Priority 5
General Fund
City ADA Transition Plan Upgrade
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
16" o.c.

PCODE WB02 Less than 18" from near side wall to center line of water closet (proposed new ADAAG: 16"-18").

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6479
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $5,000 $5,000
33"
PCODE WB03A CA only: In single-accommodation restroom less than 48" in front of water closet provided.

Remodel restroom to provide at least 48" in front of
water closet.
• As-Built Description:
• Proposed Solution:
• As-Built:
6475
2011-12 CSAS 1115B.3.2.1
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4480, Packet Page 4685 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
6485
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
12 Upper Activity Room No. 2
Door
Project Year:

Funding source:

Project:
404.2.4
20 SF $40 $800

3.2%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6495
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Drinking Fountain
Project Year:

Funding source:

Project:
602.6
1 JOB $75 $75
0" high
PCODE IA03D Drinking fountain water flow less than 4" high; unit in good condition.

Adjust water flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
6492
2011-12
ADAAG 4.15.3
CSAS 1115B.4.6.5
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Reach Range
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
Phone: 62" AFF
Coat rack: 60" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6488
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
15 Music Room
Drinking Fountain
Project Year:

Funding source:

Project:
602.6
1 JOB $75 $75
1" high
PCODE IA03D Drinking fountain water flow less than 4" high; unit in good condition.

Adjust water flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
6514
2011-12
ADAAG 4.15.3
CSAS 1115B.4.6.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Second Floor $38,700.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4481, Packet Page 4686 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
145-1-2
Hilltop Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street CIP - General Fund
Total Costs for Part: Interior $43,700.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4482, Packet Page 4687 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
147-0-1
Traffic Engineering Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
1 Parking Lot Serving Traffic Engineering Building
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
REF

6.5%
PCODE EA05BREF Access aisle at accessible parking space has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space aisle.
• As-Built Description:
• Proposed Solution:
• As-Built:
6919
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Ramps
Project Year:

Funding source:

Project:
303.4
200 SF $100 $20,000
32" level change
PCODE EB01A Ramp or lift needed to provide disabled access at steps or change of level along path of travel.

Provide new concrete ramp with handrails [slope
more than 1:20 (5.0%) needed].
• As-Built Description:
• Proposed Solution:
• As-Built:
6920
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $20,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4483, Packet Page 4688 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
147-0-1
Traffic Engineering Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Total Costs for Part: Exterior $20,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4484, Packet Page 4689 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
147-1-1
Traffic Engineering Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
1 Main Entrance
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
27" wide
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6925
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Swing
Project Year:

Funding source:

Project:
404.2.4
PCODE ID23B 1 JOB $2,600 $2,600 Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
6928
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400

2.5"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6924
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 Women's Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF

27.5" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6930
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4485, Packet Page 4690 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
147-1-1
Traffic Engineering Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
6929
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 Men's Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
20" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6931
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 1 JOB $30,000 $30,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
6932
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Corridor to Offices
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
28" - 29"
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6935
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Ramps
Project Year:

Funding source:

Project:
303.4
1 JOB $30,000 $30,000
7"
PCODE EB01A Ramp needed to provide disabled access at steps or change of level along path of travel.

Remodel area to provide access to offices.
• As-Built Description:
• Proposed Solution:
• As-Built:
6933
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4486, Packet Page 4691 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
147-1-1
Traffic Engineering Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
5 Garage Office
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
2 JOB $400 $800

1.5"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6936
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: Ground Floor $96,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4487, Packet Page 4692 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
147-1-1
Traffic Engineering Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 424 Madison St. CIP - General Fund
Total Costs for Part: Interior $96,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4488, Packet Page 4693 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
1 POT from Del Monte to Main Entrance
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 200 LF $27 $5,400 Along portola Plaza: 36" wide band of truncated domes not provided at walkway or crossing
adjoining a vehicular way, if surfaces are not
separated by a curb, railing, or other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
5273
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
Conference Center ADA
Compliance Upgrades
Slope
Project Year:

Funding source:

Project:
403.3
REF

6.7%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5272
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Walk
Project Year:

Funding source:

Project:
403.3
300 SF $25 $7,500

5.1% - 9%
PCODE EF01 Start of walk from sidewalk: Slope greater than 1:20 (5.0%), and walk does not comply with
requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
5271
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
2 Fountain Plaza
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 60 LF $27 $1,620 36" wide band of truncated domes not provided at walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
5277
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4489, Packet Page 4694 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Nosings
Project Year:

Funding source:

Project:
504.5
PCODE EC04 78 LF $16 $1,248 Stair nosings have leading edges with radius greater than 1/2".

Modify stair nosings.
• As-Built Description:
• Proposed Solution:
5276
2011-12
ADAAG 4.9.3
CSAS 1133B.4.5.1
Severity 3
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
4 Level Two Patio South (No Wheelchair Access)
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
1 JOB $75 $75

0.75"
PCODE EF04 Walk: Grating has grid openings greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
5282
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Slope
Project Year:

Funding source:

Project:
403.3
200 SF $25 $5,000

5.9% - 7.9%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5283
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
3 JOB $150 $450
79" AFF
PCODE EG01 Overhead clearance less than 80" above finished floor.

Modify overhead clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5284
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
6 Level Three Patio
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Sculpture: 10" protrusion at 60" AFF
PCODE EG04NT Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Enlarge base holding sculpture to be cane detected.
• As-Built Description:
• Proposed Solution:
• As-Built:
5291
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4490, Packet Page 4695 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Slope
Project Year:

Funding source:

Project:
403.3
7 SF $25 $175

2.3% - 4.2%
PCODE EF07 Around drainage: Cross slope more than
1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5292
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
7 Level Three SW Patio
Slope
Project Year:

Funding source:

Project:
403.3
150 SF $25 $3,750

3.5% - 3.7%
PCODE EF07 Around Drainage: Cross slope more than
1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5294
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
403.3
150 SF $25 $3,750

2.3% - 3.2%
PCODE EF07 At Del Monte and Pacific entrance: Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5295
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
PCODE EG01A 20 LF $100 $2,000 Underneath stairs: Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
5293
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
9 West Stairway from Level Three to Level Four
Slope
Project Year:

Funding source:

Project:
403.3
2 SF $25 $50

2.2% - 3.7%
PCODE EF07 At Drainage: Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
5300
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4491, Packet Page 4696 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
PCODE EG01A 25 LF $100 $2,500 Beneath Stairs: Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
5299
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
10 Ramp on Bridge to Marriott
Slope
Project Year:

Funding source:

Project:
405.2
REF

8.7% - 9.2%
PCODE EB02REF Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
5304
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 4
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
11 Jeffers Plaza
Post-Mounted Objects
Project Year:

Funding source:

Project:
307.3
1 JOB $300 $300
Plant: 50" AFF
PCODE EG05NT Free-standing object on pedestal with more than 12" cantilever from post.

Remove/relocate leaning plant so as to not be a
protrusion hazard within the access route.
• As-Built Description:
• Proposed Solution:
• As-Built:
5312
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Slope
Project Year:

Funding source:

Project:
405.7.1
48 SF $100 $4,800
Bottom landing 3.1%
PCODE EB05A At drain: Level 2% max. landing for ramp not provided.

Rebuild ramp to provide landings for each ramp run
with slopes no greater than 2%
• As-Built Description:
• Proposed Solution:
• As-Built:
5310
2011-12
ADAAG 4.8.4
CSAS 1133B.5.4.1
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Total Costs for Floor: On Site $38,718.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4492, Packet Page 4697 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-0-1
Conference Center Part: Exterior Floor: On Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Total Costs for Part: Exterior $38,718.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4493, Packet Page 4698 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
1 Portola Lobby
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
4 JOB $250 $1,000

0.5"
PCODE ID02 At main entry doors: Existing threshold at door is 3/4" high or less but without a beveled edge on both
sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
5001
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Electrical
Project Year:

Funding source:

Project:
309.2
PCODE IC06ANT 1 JOB $50 $50
Clear floor space is not 30" x 48" minimum at
informational touch screen.

Relocate existing plants.
• As-Built Description:
• Proposed Solution:
5004
2011-12 4.1.2(12) &[4.1.3(13)]
&[4.27.2]
ADAAG
1117B.6.2 CSAS
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Touch screen: 40" - 62" AFF.

PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
5005
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Telephone
Project Year:

Funding source:

Project:
704.2.2
1 JOB $250 $250
62" AFF
PCODE IB02 Telephone mounting height more than 48" to
highest operable part of phone.

Lower telephone enclosure and phone.
• As-Built Description:
• Proposed Solution:
• As-Built:
5003
2011-12
ADAAG 4.2.6
CSAS 1118B.6
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
PCODE EG01A 60 LF $100 $6,000 Beneath stairs: Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
5002
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
2 Elevator
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4494, Packet Page 4699 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Elevator
Project Year:

Funding source:

Project:
1 JOB $360 $360
42" AFF
PCODE IK08A Handrail not mounted with top 32", plus or minus one inch, above the floor of car.

Remount handrail at 32" above floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
5006
2011-12 CSAS 1116B.1.11
Severity 1
Priority 4
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:

PCODE IK10ANT 1 JOB $350 $350
Visual hall lantern, minimum 2-1/2" x 2-1/2", not
working properly.

Repair existing visual hall lantern for elevator.
• As-Built Description:
• Proposed Solution:
5007
2011-12
ADAAG 4.10.4(1)
CSAS 1116B.1.13
Severity 3
Priority 1 General Fund
Conference Center ADA
Compliance Upgrades
3 Junipero Serra Room
Signage
Project Year:

Funding source:

Project:
703.4.1
1 JOB $150 $150

57.5" AFF
PCODE SA07B At main entrance doors: Sign designating a
permanent room or space is not centered at 60"
above the finished floor.

Remount signage to 60" o.c., remodel wall as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5011
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
703.4.1
2 JOB $150 $300
65" AFF
PCODE SA07B At side entrance: Sign designating a permanent room or space is not centered at 60" above the
finished floor.

Remount signage to 60" o.c., remodel wall as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5015
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
4 Loading Area and Exit from Serra Hall
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
4 JOB $400 $1,600

1.5" - 3"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5022
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 1
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4495, Packet Page 4700 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
6 Men's Restroom (Serra 1)
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
48" - 55" from face of door
PCODE ID23BNT At stall door: At pull side, door does not have clear and level maneuvering space measuring door width
plus 18" x 60" (CA only: exterior door width plus
24").

Provide relocated new door and frame; remodel
restroom as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5038
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5037
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5030
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
5034
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
37" Wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5032
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4496, Packet Page 4701 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Urinal
Project Year:

Funding source:

Project:
605.2
1 JOB $500 $500
18" AFF
PCODE WE02A Fixture mounted with rim more than 17" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5039
2011-12
ADAAG 4.18.2
CSAS 1115B.4.2.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

19.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5035
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
7 Women's Restroom (Serra 1)
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
32" from face of door to lav;
46" from face of door to wall
PCODE ID27BNT Latch approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 24" x 48" or 54" if door has closer (CA
only: door width plus 24" x 60").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5051
2011-12
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5053
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4497, Packet Page 4702 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5045
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
8 LF $100 $800
Shelves: 8.5" protrusion at 33" AFF
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5044
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
35" in front of WC
PCODE WB03 Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5050
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
37" Wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5049
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
8 Men's Restroom (Serra 2)
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5065
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4498, Packet Page 4703 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 27.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5057
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Shelves: 55" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
5061
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
5060
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
33" in front of WC
PCODE WB03 Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5064
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
604.8.1.1
PCODE WB06 1 JOB $1,500 $1,500 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
5063
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4499, Packet Page 4704 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Urinal
Project Year:

Funding source:

Project:
1 JOB $4,000 $4,000
13" from wall
PCODE WE01 CA only: Front of rim projects less than 14" from wall.

Provide accessible urinal. Remodel restroom as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5059
2011-12 CSAS 1115B.4.2.1
Severity 4
Priority 5
General Fund
Conference Center ADA
Compliance Upgrades
9 Women's Restroom (Serra 2)
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5074
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.5" knee
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5073
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
8 LF $100 $800
Shelves: 8.5" protrusion at 33" AFF
PCODE EG04A Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5072
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4500, Packet Page 4705 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
32" in front of WC
PCODE WB03 Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5079
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500

36.5" wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5078
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
12 Stairs to Green Room and Restroom 109B (dressing room) Restroom
Project Year:

Funding source:

Project:
603
1 JOB $30,000 $30,000
36" wide
PCODE WA01 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
• As-Built:
5091
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
2 JOB $75 $150
Shelf and coat hanger: 65" AFF
PCODE EG01 Overhead clearance less than 80" above finished floor.

Modify overhead clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5092
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
13 Dressing Room 109C
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4501, Packet Page 4706 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Restroom
Project Year:

Funding source:

Project:
603
1 JOB $30,000 $30,000
36" wide
PCODE WA01 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
• As-Built:
5096
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
1 JOB $75 $75
Shelf and coat hanger: 65" AFF
PCODE EG01 Overhead clearance less than 80" above finished floor.

Modify overhead clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
5097
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
14 Ramp Serving Stage
Rise
Project Year:

Funding source:

Project:
405.6
160 SF $100 $16,000
41" no landing.

PCODE EB05 Ramp: Rise more than 30" between landings.

Rebuild ramp to provide landings at 30" maximum
rise.
• As-Built Description:
• Proposed Solution:
• As-Built:
5099
2011-12
ADAAG 4.8.2
CSAS 1133B.5.4.1
Severity 3
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Slope
Project Year:

Funding source:

Project:
405.2
160 REF

9.3% - 9.8%
PCODE EB02REF Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
5100
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
16 NW Stairway Serra 2
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Hand sanitizer: 57"
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
5117
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4502, Packet Page 4707 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Tables and Cubicles
Project Year:

Funding source:

Project:
2 JOB $1,600 $3,200
PTD: 55" AFF
SD: 48" at 31" deep
PCODE IN01 Accessible fixed worktables or cubicles for disabled individuals not provided.

Provide accessible tables or cubicles.
• As-Built Description:
• Proposed Solution:
• As-Built:
5116
2011-12
ADAAG 4.32.1
CSAS 1122B.1
Severity 1
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
17 Kitchen
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
27" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5123
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01 2 JOB $30,000 $60,000 Single accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide single-occupant accessible
restroom.
• As-Built Description:
• Proposed Solution:
5122
2011-12
ADAAG 4.22
CSAS 1115B.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
20 Conference Center Offices (Staff Area)
Door Swing
Project Year:

Funding source:

Project:
404.2.4
PCODE ID24ANT 1 JOB $250 $250
Front approach: At push side, door does not have
clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Remove or relocate planter.
• As-Built Description:
• Proposed Solution:
5132
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 4
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4503, Packet Page 4708 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-1
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
46" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
5135
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 4
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Total Costs for Floor: Second Floor $180,535.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4504, Packet Page 4709 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
3 Dana Room
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 25" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5147
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
4 Corridor to Meeting Rooms
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
10 JOB $50 $500
78" AFF
PCODE EG01 Light fixtures: Overhead clearance less than 80" above finished floor.

Provide new fixtures.
• As-Built Description:
• Proposed Solution:
• As-Built:
5156
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
6 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
TPD: 41" from back wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
5173
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF

42.5" from face of door to wall
PCODE ID23BREF Stall door: At pull side, door does not have clear and level maneuvering space measuring door width
plus 18" x 60" (CA only: exterior door width plus
24").

Provide relocated new stall door and frame;
remodel walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5174
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4505, Packet Page 4710 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
Door width + 9" to DF
PCODE ID24ANT Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
5163
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5171
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $900 $900

34.5" AFF
PCODE WD02A Lavatory: Fixture rim or counter height more than 34" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5165
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
33" in front of WC
PCODE WB03REF Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5168
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
38" wide
PCODE WB06 Toilet stall less than 60" wide.

Remove urinal and redesign area.
• As-Built Description:
• Proposed Solution:
• As-Built:
5167
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4506, Packet Page 4711 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Urinal
Project Year:

Funding source:

Project:
1 JOB $4,000 $4,000
13" deep
PCODE WE01 CA only: Front of rim projects less than 14" from wall.

Provide accessible urinal. Remodel restroom as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5166
2011-12 CSAS 1115B.4.2.1
Severity 4
Priority 5
General Fund
Conference Center ADA
Compliance Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
19" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5172
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
7 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
42" from back wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
5186
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
40" from face of door to wall
PCODE ID23BREF Front approach: At pull side, stall door does not have clear and level maneuvering space measuring
door width plus 18" x 60" (CA only: exterior door
width plus 24").

Remove one water closet and remodel area to add
accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5187
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4507, Packet Page 4712 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5183
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $900 $900

32.5" AFF
PCODE WD02A Lavatory: Fixture rim or counter height more than 34" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5179
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
33" to WC
PCODE WB03REF Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
5181
2011-12
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
37" Wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5180
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

19.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5184
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4508, Packet Page 4713 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-2
Conference Center Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Total Costs for Floor: Second Floor $13,100.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4509, Packet Page 4714 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
1 Steinbeck Lobby
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
5 JOB $400 $2,000

0.75" - 1.5"
PCODE ID02A Door to patio's inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5190
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
TV: 7" protrusion at 77" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5191
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
3 Ferrante Rooms (I, II, III)
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Door width + 8"
PCODE ID24 Room three at front approach: At push side, door does not have clear and level maneuvering space
measuring door width x 48" (door width plus 12" if
door has both, latch and closer).

Change latch to hinge side.
• As-Built Description:
• Proposed Solution:
• As-Built:
5200
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
3 JOB $400 $1,200

1.5"
PCODE ID02A At exit door: Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5204
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 2
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
4 Restroom Corridor
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4510, Packet Page 4715 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400
1"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5208
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
5 Women's Restroom
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
44" from face of door to LAV
PCODE ID23BNT Stall door front approach: At pull side, door does not have clear and level maneuvering space
measuring door width plus 18" x 60" (CA only:
exterior door width plus 24").

Remodel bathroom and provide accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5213
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07REF REF
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5215
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $900 $900

34.5" AFF
PCODE WD02A Lavatory: Fixture rim or counter height more than 34" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5211
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF

39.5" wide
PCODE WB06REF Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
• As-Built:
5214
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4511, Packet Page 4716 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

17.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5216
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
6 Men's Restroom
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07REF REF
Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
5225
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $900 $900

34.5" AFF
PCODE WD02A Lavatory: Fixture rim or counter height more than 34" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5221
2011-12
ADAAG 4.19.2
CSAS 1115B.4.3
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Shelf: 56" AFF
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
7048
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
38" wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5226
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4512, Packet Page 4717 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Urinal
Project Year:

Funding source:

Project:
1 JOB $4,000 $4,000
Urinal: 13" from wall
PCODE WE01 CA only: Front of rim projects less than 14" from wall.

Provide accessible urinal. Remodel restroom as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5222
2011-12 CSAS 1115B.4.2.1
Severity 4
Priority 5
General Fund
Conference Center ADA
Compliance Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

18.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
5228
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
7 Steinbeck Forum East Entrance and Stairwell
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400
1" threshold and cables along door
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5239
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Lifts
Project Year:

Funding source:

Project:
410.1 & 410.6
PCODE IO02 1 JOB $5,000 $5,000 No automatic doors provided.

Provide automatic doors at wheelchair lift.
• As-Built Description:
• Proposed Solution:
7016
2011-12
ADAAG 4.11.3
CSAS 1116B.4
Severity 3
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Stairs
Project Year:

Funding source:

Project:
1 JOB $6,500 $6,500

10.5%
PCODE EC06NT Landing between stairs is not level 2% max.

Rebuild stair as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5236
2011-12 CSAS 1009.6.1
Severity 1
Priority 4
General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4513, Packet Page 4718 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
8 Steinbeck Forum West Entrance and Stairwell
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400

0.75"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5248
2011-12
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 1
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Stairs
Project Year:

Funding source:

Project:
1 JOB $6,500 $6,500

10.1%
PCODE EC06NT Landing between stairs is not level 2% max.

Rebuild stair as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
5245
2011-12 CSAS 1009.6.1
Severity 1
Priority 4
General Fund
Conference Center ADA
Compliance Upgrades
9 Steinbeck Forum Assembly Area and Stage
Fixed Seating
Project Year:

Funding source:

Project:
2 EA $600 $1,200
494 total seats
2 provided
38" x 48"
PCODE GE01 Proper amount of seating for disabled persons at public seating is not provided (>25=1; >50=2;
>300=4; >500=6; +500=6=1%).

Modify seating to provide clear and level
wheelchair space 33" x 48" or 33" x 60", including
companion seat, as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
5249
2011-12
ADAAG 4.1.2(19)a
CSAS 1104B.3.4
Severity 2
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:

PCODE GE01A 5 EA $350 $1,750 Less than one percent of total seating are aisle seats with removable armrest (at aisle side) that are
identified by by a sign.

Provide aisle seats with no or removable armrest
and post availability at ticket office.
• As-Built Description:
• Proposed Solution:
5250
2011-12
ADAAG 4.1.2(19)a
CSAS 1104B.3.4
Severity 2
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4514, Packet Page 4719 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Project Year:

Funding source:

Project:

PCODE GE01BREF REF
At least one fixed companion seat next to each
wheelchair seating area is not provided.

Provide one companion seat next to each accessible
wheelchair space(s).
• As-Built Description:
• Proposed Solution:
5253
2011-12
ADAAG 4.33.3
CSAS 1104B.3.5
Severity 2
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
Project Year:

Funding source:

Project:

PCODE GE01CREF REF
Wheelchair locations not dispersed throughout
seating area (n/a if floor slope greater than 1:20 or
5%).

Disperse accessible wheelchair space(s).
• As-Built Description:
• Proposed Solution:
5254
2011-12
ADAAG 4.33.3
CSAS 1104B.3.3
Severity 2
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
Public Participation Counter
Project Year:

Funding source:

Project:
1 JOB $2,000 $2,000
41" AFF
PCODE GB02A On stage: Speaker podium is not accessible. Upper edge of podium is more than 40" above the finished
floor, and knee space is less than 27" high, 30"
wide, and 19" deep.

Provide additional, integrated, and accessible
speaker podium.
• As-Built Description:
• Proposed Solution:
• As-Built:
5252
2011-12
ADAAG 4.32.3
CSAS 1122B.3
Severity 2
Priority 2 General Fund
Conference Center ADA
Compliance Upgrades
10 Dressing Room Steinbeck Forum
Corridor
Project Year:

Funding source:

Project:
1 JOB $50 $50
27" between server and table
PCODE IH03A Corridor, for occupant load less than 10, less than 36" wide.

Remove or relocate furniture and storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
5270
2011-12
ADAAG 4.3.3
CSAS 1133B.3.1
Severity 2
Priority 3 General Fund
Conference Center ADA
Compliance Upgrades
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
27" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
5268
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
Conference Center ADA
Compliance Upgrades
Total Costs for Floor: Third Floor $41,600.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4515, Packet Page 4720 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
109-1-3
Conference Center Part: Interior Floor: Third Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 1 Portola Plaza CIP - General Fund
Total Costs for Part: Interior $235,235.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4516, Packet Page 4721 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-0-1
Library Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
1 Accessible Parking Serving Library
Parking
Project Year:

Funding source:

Project:
502.3
REF
6'-13' wide
PCODE EA02BREF Accessible parking space does not have 5' wide access aisle; 8' wide for van accessible aisle (CA
only: aisle spaces need to be 18' in length).

Modify parking aisle(s) to create accessible space
by restriping.
• As-Built Description:
• Proposed Solution:
• As-Built:
3221
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 2
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04E 1 JOB $315 $315
Sign for "Van Accessible" space is located at stall
where the van accessible aisle is located on the
driver side of the vehicle.

Remove the words "Van Accessible" from existing
sign.
• As-Built Description:
• Proposed Solution:
3220
2011-12 CSAS 1129B.4
Severity 4
Priority 4
General Fund
Library ADA Compliance
Upgrades
2 Ramp from Parking to Entrance
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 5 LF $27 $135
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
3225
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
Library ADA Compliance
Upgrades
Slope
Project Year:

Funding source:

Project:
405.7.1
36 SF $100 $3,600

5.3%
PCODE EB05A Level 2% max. bottom landing for ramp not
provided.

Rebuild ramp to provide landings for each ramp run
with slopes no greater than 2%
• As-Built Description:
• Proposed Solution:
• As-Built:
3222
2011-12
ADAAG 4.8.4
CSAS 1133B.5.4.1
Severity 3
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
3 Stairs to Basement
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4517, Packet Page 4722 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-0-1
Library Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Floor or Ground Surface
Project Year:

Funding source:

Project:
403.2; 302.3
1 JOB $160 $160
1" opening
PCODE EF04 Walk: Grating has grid openings greater than 1/2" along the line of traffic flow.

Provide new grating, with grid openings 1/2" max.
along the line of traffic flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
3229
2011-12
ADAAG 4.3.6; 4.5.4
CSAS 1133B.7.2
Severity 2
Priority 4
ADA-2010
General Fund
Library ADA Compliance
Upgrades
4 Upper Patio Area and Rear Entrance
Door
Project Year:

Funding source:

Project:
404.2.4
REF

4.5%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Automatic door opener provided.
• As-Built Description:
• Proposed Solution:
• As-Built:
3231
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Nosings
Project Year:

Funding source:

Project:
504.5
PCODE EC01 9 LF $20 $180
Stair nosings project more than 1-1/2" past face of
riser and/or are not beveled on underside 60° min.
from horizontal.

Modify stair nosings at step to lower patio.
• As-Built Description:
• Proposed Solution:
3230
2011-12
ADAAG 4.9.3
CSAS 1133B.4.5.2
Severity 4
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
5 Main Entrance at Pacific Street
Walk
Project Year:

Funding source:

Project:
403.3
64 SF $25 $1,600

9.6%-10.2%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
3233
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
6 Book Mobile
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4518, Packet Page 4723 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-0-1
Library Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Ramps
Project Year:

Funding source:

Project:
303.4
1 JOB $450 $450

1.5" change in level
PCODE EB04NT Book mobile metal ramp has abrupt change in level exceeding 1/2".

Modify area of abrupt change in level to provide
smooth transition.
• As-Built Description:
• Proposed Solution:
• As-Built:
3234
2011-12
ADAAG 4.5.2
CSAS 1133B.7.1
Severity 2
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Total Costs for Floor: On-Site $6,440.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4519, Packet Page 4724 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-0-1
Library Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Total Costs for Part: Exterior $6,440.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4520, Packet Page 4725 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-0
Library Part: Interior Floor: Basement
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
1 Stairs to Basement
Door Swing
Project Year:

Funding source:

Project:
404.2.4
PCODE ID24BNT 1 JOB $2,600 $2,600 Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
3426
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 4
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Stairway
Project Year:

Funding source:

Project:

PCODE II02C 45 LF $16 $720
Stair nosings project more than 1-1/2" past face of
riser and/or not beveled on underside 60° min. from
horizontal.

Modify stair nosings.
• As-Built Description:
• Proposed Solution:
3425
2011-12
ADAAG 4.9.3
CSAS 1133B.4.5.2
Severity 3
Priority 4 General Fund
Library ADA Compliance
Upgrades
2 Basement
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
Door width + 9" to furniture items
PCODE ID24A Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
3428
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 4
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Total Costs for Floor: Basement $3,370.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4521, Packet Page 4726 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
1 Circulation Area and Main Floor
Desk
Project Year:

Funding source:

Project:
306.1
2 JOB $2,500 $5,000
Knee space: 14.5" & 11.5" deep
PCODE IN02NT Accessible fixed table or desk (#15 Internet PC & #14 Library Catalog PC) not provided.

Provide new accessible workstations for each type
(top 28" to 34" high; knee space at least 27" high x
19" deep x 30" wide).
• As-Built Description:
• Proposed Solution:
• As-Built:
3235
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Top: 25" high
PCODE IN02NT Accessible fixed table or desk (Print Station) not provided.

Provide new fixed accessible table or desk (top 28"
to 34" high; knee space at least 27" high x 19" deep
x 30" wide).
• As-Built Description:
• Proposed Solution:
• As-Built:
3237
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 3
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Top: 39" high
PCODE IN02NT Accessible fixed table or desk (#21) not provided.

Provide new fixed accessible table or desk (top 28"
to 34" high; knee space at least 27" high x 19" deep
x 30" wide) .
• As-Built Description:
• Proposed Solution:
• As-Built:
3245
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 4
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
306.1
2 JOB $2,500 $5,000
Knee space: 23.5" & 26.5" high
PCODE IN02NT Accessible fixed table or desk (magnifier & microfiche) not provided.

Provide new fixed accessible table or desk (top 28"
to 34" high; knee space at least 27" high x 19" deep
x 30" wide) .
• As-Built Description:
• Proposed Solution:
• As-Built:
3246
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
306.1
REF
Top: 40" high
PCODE IN02REF Accessible fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30" wide)
not provided."
Provide new fixed accessible table or desk.
• As-Built Description:
• Proposed Solution:
• As-Built:
3242
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 3
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4522, Packet Page 4727 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 26.5" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
3244
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Open Stack
Project Year:

Funding source:

Project:
1 JOB $0
36" - 40"
PCODE BB01A Open stacks (i.e. public use) do not have min. 36" (44" preferred) wide aisles (CA only: 44" min.
width at main aisles and 36" min. at end aisles).

Provide attendant when needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3243
2011-12
ADAAG 8.5
CSAS 1106B.4.2
Severity 4
Priority 1 General Fund
Library ADA Compliance
Upgrades
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Printer: 52" in height
18" in depth
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3238
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
Self checkout station: 53" in height
15" in depth
PCODE IE01 Reach height to control or access point exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
3241
2011-12
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 1
ADA-2010
General Fund
Library ADA Compliance
Upgrades
2 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
53" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3262
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 1
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4523, Packet Page 4728 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3261
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
Library ADA Compliance
Upgrades
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
PCODE ID01NT 1 JOB $150 $150
Door on accessible route has less than 32" clear
opening because stall door does not open 90° due to
baby changing station. (CA only:...or has leaf size
less than 36" wide or 80" high).

Remove or relocate baby changing station to
provide required clear opening at stall.
• As-Built Description:
• Proposed Solution:
3253
2011-12
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 46" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3264
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
30" long GB extends 34" from rear wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3265
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
PCODE WB07INT 1 JOB $75 $75
Flush control in front of obstructs use of rear grab
bar.

Modify flush control so as to not obstruct use of
rear grab bar.
• As-Built Description:
• Proposed Solution:
3256
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4524, Packet Page 4729 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Project Year:

Funding source:

Project:
609.3
REF
TPD: 4" below SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
3263
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.2
PCODE WD01 1 JOB $3,400 $3,400 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
3250
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3266
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Shelf: 5" protrusion at 42" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3252
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
3254
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4525, Packet Page 4730 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
57" wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3260
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $4,500 $4,500
14" o.c.

PCODE WB02 Less than 18" from near side wall to center line of water closet (2010 ADAAG: 16"-18").

Provide new accessible water closet and relocate
plumbing.
• As-Built Description:
• Proposed Solution:
• As-Built:
3259
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
3 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
54" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3284
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 1
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3283
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
Library ADA Compliance
Upgrades
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
33" from face of door to partition wall
PCODE ID23BNT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3288
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4526, Packet Page 4731 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
2 JOB $500 $1,000
30" long
PCODE WB07 Grab bars not provided or are not code compliant.

Provide accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
3282
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
PCODE WB07IREF REF
Flush control in front of obstructs use of rear grab
bar.

Modify flush control so as to not obstruct use of
rear grab bar.
• As-Built Description:
• Proposed Solution:
3281
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400

16.5" o.c.

PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3271
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 25.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3272
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Shelf: 5" protrusion at 47" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3273
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4527, Packet Page 4732 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
3275
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
58" in front of WC
PCODE WB04 Less than 95" from back wall to front wall of side entry toilet stall when door swings inward, or less
than 92" if water closet is wall-hung (CA only: Less
than 60" from front of water closet to opposite wall
in side entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
3286
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.2
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
56" wide
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3285
2011-12
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Urinal
Project Year:

Funding source:

Project:
605.2
1 JOB $500 $500
20" AFF
PCODE WE02A Fixture mounted with rim more than 17" above floor.

Remount compliant fixture at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3278
2011-12
ADAAG 4.18.2
CSAS 1115B.4.2.1
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
605.3
1 JOB $1,500 $1,500
32" wide & 40" deep
PCODE WE04A 36" wide clearance in front of accessible urinal not provided when walls or partitions project more than
24" from the front edge of 30" x 48" clear space.

Provide 36" clear floor space in front of accessible
urinal. Remodel restroom as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3279
2011-12
ADAAG 4.18.3
CSAS 1115B.4.2.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4528, Packet Page 4733 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
3280
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
4 Corridor to Restrooms and Community Rooms
Doormat
Project Year:

Funding source:

Project:
302.2
PCODE ID05 1 JOB $500 $500
Doormat hinders access to disabled persons.

Provide new doormat; recess or attach at edges.
• As-Built Description:
• Proposed Solution:
3290
2011-12
ADAAG 4.5.3
CSAS 1124B.3
Severity 3
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
6 Community Room
Door
Project Year:

Funding source:

Project:
404.2.11
2 JOB $2,500 $5,000
58" AFF
PCODE ID06C Vision Light at door that permits viewing, does not have bottom of at least one glazed panel located 43
inches maximum above the finish floor. (Exception:

More than 66" above finished floor.)
Provide new door with vision panel at 43" max.
above finish floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
3294
2011-12
Severity 1
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
8 Conference Room
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Knee space: 25" & 26.5" high
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
3307
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
9 Stairs Adjacent to Elevator
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4529, Packet Page 4734 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Stairway
Project Year:

Funding source:

Project:

PCODE II02D 56 LF $36 $2,016 Stair does not have closed risers.

Modify stair to have closed risers.
• As-Built Description:
• Proposed Solution:
3309
2011-12
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 3
Priority 2 General Fund
Library ADA Compliance
Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
16 LF $100 $1,600
35" AFF
PCODE EG01A Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
3312
2011-12
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
10 Elevator
Elevator
Project Year:

Funding source:

Project:

REF
32" wide
PCODE IK03REF Door opening has less than 36" clear opening width.

Enlarge elevator door opening to 36" width.
• As-Built Description:
• Proposed Solution:
• As-Built:
3315
2011-12
ADAAG 4.10.9
CSAS 1116B.1.4
Severity 3
Priority 1 General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
1 JOB ? $120,000
62" wide
PCODE IK04A In an elevator cab with 36” wide side slide opening doors, cab-size is not 68” min. wide and/or 54”
min. deep between the back wall and the elevator
door, and 51” min. deep between the back wall and
the return panel.

Provide new elevator.
• As-Built Description:
• Proposed Solution:
• As-Built:
3318
2011-12
ADAAG Fig. 22
CSAS 1116B.1.8
Severity 4
Priority 1 General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IK07AREF REF
Elevator control panel buttons less than 3/4"
minimum dimension and/or not raised at least 1/8".

Provide new elevator control panel buttons.
• As-Built Description:
• Proposed Solution:
3317
2011-12
ADAAG 4.10.12(1)
CSAS 1116B.1.9
Severity 3
Priority 1 General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4530, Packet Page 4735 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Project Year:

Funding source:

Project:

PCODE IK10AREF REF
Visual hall lantern, minimum 2-1/2" x 2-1/2", not
provided, or installed less than 6' above floor.

Provide or raise proper visual hall lantern for
elevator.
• As-Built Description:
• Proposed Solution:
3316
2011-12
ADAAG 4.10.4(1)
CSAS 1116B.1.13
Severity 3
Priority 1 General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IK11A 1 SET $50 $50
Star not provided at floor identifying jamb signs.

Provide compliant floor numbering on elevator
door jambs (each floor).
• As-Built Description:
• Proposed Solution:
3319
2011-12 CSAS 1116B.1.14
Severity 3
Priority 4
General Fund
Library ADA Compliance
Upgrades
13 Staff Area
Locker Facilities
Project Year:

Funding source:

Project:

PCODE GG04 1 JOB $750 $750
Accessible locker(s) in dressing room not provided
(1% of lockers; not less than one).

Provide new locker(s) with accessible locking
hardware that is operable with one hand and does
not require grasping, pinching or twisting.
• As-Built Description:
• Proposed Solution:
3333
2011-12
ADAAG 4.1.3(12)(a)
CSAS 1115B.8.5
Severity 3
Priority 4 General Fund
Library ADA Compliance
Upgrades
15 Unisex Restroom 1
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
46" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3343
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3344
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4531, Packet Page 4736 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 51" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3346
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
PCODE WB07I 1 JOB $75 $75
Flush valve in accessible stall located closer than 1
-1/2" below or 18" above grab bar impedes its use.

Modify plumbing to allow flush valve no closer
than 1-1/2" below and 18" above grab bars (except
if accessories are recessed, flush with wall, and
have no sharp edges).
• As-Built Description:
• Proposed Solution:
3341
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
TPD: 2" above SGB
Shelf: 8" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
3345
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400
13" o.c.

PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3347
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4532, Packet Page 4737 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

16.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3342
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
16 Unisex Restroom 2
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
44" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3365
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3364
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
Library ADA Compliance
Upgrades
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
57" from face of door to lavatory
PCODE ID23BNT Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3362
2011-12
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4533, Packet Page 4738 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 52" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3361
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
30" long
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3360
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
TPD: 6" above SGB
Shell: 8" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
3359
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
PCODE WB07IREF REF
Flush valve in accessible stall located closer than 1
-1/2" below or 18" above grab bar impedes its use.

Modify plumbing to allow flash valve no closer
than 1-1/2" below and 18" above grab bars (except
if accessories are recessed, flush with wall, and
have no sharp edges).
• As-Built Description:
• Proposed Solution:
3353
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4534, Packet Page 4739 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400

13.5" o.c.

PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3355
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3356
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500
17" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3358
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
3352
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Total Costs for Floor: Ground Floor $188,226.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4535, Packet Page 4740 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
1 General Stack Area
Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $2,500 $2,500
Top: 39" high
PCODE IN02NT Accessible fixed table or desk (Catalog PC) not provided."
Provide new fixed accessible table or desk (top 28"
to 34" high; knee space at least 27" high x 19" deep
x 30" wide).
• As-Built Description:
• Proposed Solution:
• As-Built:
3368
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 4
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Table
Project Year:

Funding source:

Project:
902.1
1 JOB $800 $800
Knee space: 26.5" high
PCODE BE03 Study carrels or tables: Less than 5% have
accessible height (28" to 34") and 27" clear knee
space.

Provide accessible study carrel or worktable unit.
• As-Built Description:
• Proposed Solution:
• As-Built:
3367
2011-12
ADAAG 8.2
CSAS 1106B.3
Severity 4
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
28 JOB $400 $11,200
78" AFF
PCODE EG02NT Slanted utility guy wire adjacent to accessible route walkway creates overhead obstruction within 80"
height from surface.

Provide guy brace to vertically align guy wire
within 80" height from walkway surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
3366
2011-12
ADAAG 4.4.2
CSAS 1133B.8.2
Severity 4
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
2 Mezzanine Patio
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $250 $250

0.5"
PCODE ID02 Existing threshold at door is 3/4" high or less but without a beveled edge on both sides.

Modify threshold to have beveled edge on each
side.
• As-Built Description:
• Proposed Solution:
• As-Built:
3371
2011-12
ADAAG 4.1.6(3)(d)(ii)
CSAS 1133B.2.4.1
Severity 4
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4536, Packet Page 4741 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
25" wide
PCODE IN02A Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
3372
2011-12
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 2
ADA-2010
General Fund
Library ADA Compliance
Upgrades
5 Unisex Restroom 1
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
42" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3392
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3393
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
Library ADA Compliance
Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 52" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3391
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
30" long
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3389
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4537, Packet Page 4742 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Project Year:

Funding source:

Project:
604.5
1 JOB $260 $260
30" AFF
PCODE WB07C Grab bars not at 33" to 36" from floor (CA only:
33" from floor if no tank toilet).

Relocate accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
3390
2011-12
ADAAG 4.16.4
CSAS 1115B.4.1.3.1 & 2
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75
TPD: 4" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
3394
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
PCODE WB07INT 1 JOB $75 $75
Flash valve in accessible stall located closer than 1
-1/2" below or 18" above grab bar impedes its use.

Modify plumbing to allow flash valve to be no
closer than 1-1/2" below and 18" above grab bars
(except if accessories are recessed, flush with wall,
and have no sharp edges).
• As-Built Description:
• Proposed Solution:
3388
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400

13.5" o.c.

PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3384
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400
Knee space: 26" high
PCODE WD04 Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3383
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4538, Packet Page 4743 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07B 1 JOB $150 $150
Sign designating a permanent room or space is not
centered at 60" above the finished floor.

Remount signage to 60" o.c., remodel wall as
needed.
• As-Built Description:
• Proposed Solution:
3381
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Toilet Stall
Project Year:

Funding source:

Project:
1 JOB $750 $750
46" in front of water closet
PCODE WB01BNT CA only: In existing buildings a single
accommodation restroom has less than 60" wide x
48" deep space in front of a water closet.

Provide shorter water closet , repair tiled surfaces,
patch finishes to match and repaint as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3395
2011-12 CSAS 1115B.4.1.2
Severity 2
Priority 5
General Fund
Library ADA Compliance
Upgrades
Water Closet
Project Year:

Funding source:

Project:
604.2
1 JOB $500 $500

16.5" o.c.

PCODE WB02C Water closet not located at 18" from near side wall to center line of water closet (2010 ADAAG:
16"-18").

Relocate existing water closet and plumbing,
remount with offset closet flange to provide 18"
from side wall.
• As-Built Description:
• Proposed Solution:
• As-Built:
3387
2011-12
ADAAG Fig. 28
CSAS 1115B.4.1.1
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
6 Unisex Restroom 2
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
TPD: 47" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3412
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4539, Packet Page 4744 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
3413
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
Library ADA Compliance
Upgrades
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 52" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3411
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
30" long
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
3409
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
604.5
REF
32" AFF due to recessed SCD
PCODE WB07CREF Grab bars not at 33" to 36" from floor (CA only:
33" from floor if no tank toilet).

Relocate accessible grab bars & recess seat cover
dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
3410
2011-12
ADAAG 4.16.4
CSAS 1115B.4.1.3.1 & 2
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75
TPD: 6" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
3414
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4540, Packet Page 4745 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Project Year:

Funding source:

Project:
609.3
PCODE WB07INT 1 JOB $75 $75
Flash valve in accessible stall located closer than 1
-1/2" below or 18" above grab bar impedes its use.

Modify plumbing to allow flash valve to be no
closer than 1-1/2" below and 18" above grab bars
(except if accessories are recessed, flush with wall,
and have no sharp edges).
• As-Built Description:
• Proposed Solution:
3407
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400

15.5" o.c.

PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3404
2011-12
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
606.3
1 JOB $3,400 $3,400
Knee space: 25" high
PCODE WD04 Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Provide new accessible lavatory. Remodel restroom
as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
3403
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07B 1 JOB $150 $150
Sign designating a permanent room or space is not
centered at 60" above the finished floor.

Remount signage to 60" o.c., remodel wall as
needed.
• As-Built Description:
• Proposed Solution:
3401
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 4
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Toilet Stall
Project Year:

Funding source:

Project:

PCODE WB01BNT 1 JOB $750 $750
CA only: In existing buildings a single
accommodation restroom has less than 60" wide x
48" deep space in front of a water closet.

Provide shorter water closet , repair tiled surfaces,
patch finishes to match and repaint as needed.
• As-Built Description:
• Proposed Solution:
3415
2011-12 CSAS 1115B.4.1.2
Severity 2
Priority 5
General Fund
Library ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4541, Packet Page 4746 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.6
PCODE WB10REF REF
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
3408
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
Library ADA Compliance
Upgrades
Total Costs for Floor: Second Floor $34,160.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4542, Packet Page 4747 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. CIP - General Fund
Total Costs for Part: Interior $225,756.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4543, Packet Page 4748 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
2 Accessible Parking Spaces
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 8 JOB $100 $800
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
3681
2011-12 CSAS 1129B.4
Severity 4
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
5 Exit Ramp at Del Monte Avenue
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Washington Street.
• As-Built Description:
• Proposed Solution:
3695
2011-12
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
6 Exit Ramp at Del Monte Avenue
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
3700
2011-12
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Total Costs for Floor: On-Site $1,260.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4544, Packet Page 4749 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-0-1
Monterey Sports Center Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Total Costs for Part: Exterior $1,260.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4545, Packet Page 4750 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
1 Main Entrance and Lobby
Brochure Bins
Project Year:

Funding source:

Project:
1 JOB $100 $100
63" AFF
PCODE IN08 Information brochure bins mounted above
accessible height (48" for front approach or 54" for
side approach).

Relocate/remount bins at accessible height, or
provide same information at lower bins.
• As-Built Description:
• Proposed Solution:
• As-Built:
3433
2011-12
ADAAG 4.2.5 & 6
CSAS 1118B.5
Severity 3
Priority 1 General Fund
Sports Center ADA Compliance
Upgrades
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150
47" high
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
3432
2011-12
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
2 Elevator Lobby and Stairway
Elevator
Project Year:

Funding source:

Project:

PCODE IK11 1 JOB $50 $50
Floor numbers not provided at all elevator entrances
with both raised characters 2" high and Braille
numbers, on each entrance jamb.

Provide compliant floor numbering on elevator
door jambs.
• As-Built Description:
• Proposed Solution:
3437
2011-12
ADAAG 4.10.5*
CSAS 1116B.1.14
Severity 3
Priority 1 General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IK11NT 1 SET $50 $50
Braille symbols on floor indicators of each elevator
entrance jamb not compliant.

Provide compliant floor numbering with star on
elevator door jambs.
• As-Built Description:
• Proposed Solution:
3436
2011-12 CSAS 1116B.1.14
Severity 3
Priority 4
General Fund
Sports Center ADA Compliance
Upgrades
3 Central Corridor
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4546, Packet Page 4751 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain is provided per floor: Fountain is not accessible to individuals who
use wheelchairs, or to those who have difficulty
bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
3449
2011-12
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
602.2
1 JOB $1,200 $1,200
Knee space: 26" high
PCODE IA02A Wall- and post-mounted cantilevered units: Knee space not provided at drinking fountain (27" high,
8" deep, 30" wide from front of drinking fountain).

Unit in good condition.

Remount fountain at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3448
2011-12
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3447
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
4 Men's Restroom at West Corridor
Signage
Project Year:

Funding source:

Project:

PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.

CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
3453
2011-12 CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
Sports Center ADA Compliance
Upgrades
5 Women's Restroom at West Corridor
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4547, Packet Page 4752 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Signage
Project Year:

Funding source:

Project:

PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.

CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
3463
2011-12 CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
Sports Center ADA Compliance
Upgrades
6 Operations Manager Offices
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor at entrance door.
• As-Built Description:
• Proposed Solution:
3473
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 4 JOB $50 $200
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor (Doors located
inside of office space).
• As-Built Description:
• Proposed Solution:
3475
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10D 1 JOB $90 $90
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
3476
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
7 Studio 1
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4548, Packet Page 4753 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3477
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
3482
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
8 Kid Zone
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3485
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
3489
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4549, Packet Page 4754 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:
216.8
PCODE SA11ANT 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3494
2011-12
ADAAG 4.1.3(16)(a)
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
9 Weight Training Center
Drinking Fountain
Project Year:

Funding source:

Project:
602.4
1 JOB $3,200 $3,200
38" AFF
PCODE IA03B Drinking fountain bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
3503
2011-12
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3502
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3500
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4550, Packet Page 4755 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
3504
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
10 Physical Therapy Room
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 2 JOB $50 $100
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor at fitness
manager's office.
• As-Built Description:
• Proposed Solution:
3506
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
11 Cardio Fitness Center
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor at main entrance
door from corridor.
• As-Built Description:
• Proposed Solution:
3510
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
3508
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4551, Packet Page 4756 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
3509
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
12 Gymnasium
Signage
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10A 1 JOB $90 $90
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
3512
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
14 Family Dressing Room
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3524
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
15 Men's Locker and Shower Room
Drinking Fountain
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3530
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4552, Packet Page 4757 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Signage
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10B 2 JOB $90 $180
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
3553
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10D 1 JOB $90 $90
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
3536
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3532
2011-12
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3533
2011-12 CSAS 1115B.6
Severity 3
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
16 Natatorium
Drinking Fountain
Project Year:

Funding source:

Project:
602.2
PCODE IA02 1 JOB $3,200 $3,200 Wall- and post-mounted cantilevered units: Knee space not provided at drinking fountain (27" high,
8" deep, 30" wide from front of drinking fountain).

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
3580
2011-12
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4553, Packet Page 4758 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3579
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
602.2
PCODE IA06REF REF
30" wide x 48" long clear floor space not provided
at drinking fountain due to bleacher.

Relocate bleacher to provide clear floor space at
drinking fountain.
• As-Built Description:
• Proposed Solution:
3583
2011-12
ADAAG 4.15.5(1)*
CSAS 1115B.4.6.3
Severity 2
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 1 JOB $50 $50
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3558
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10A 5 JOB $90 $450
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT" sign at door.
• As-Built Description:
• Proposed Solution:
3574
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
17 North Side Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4554, Packet Page 4759 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 2 JOB $50 $100
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3598
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
703.2
PCODE SA07ANT 1 JOB $150 $150
Sign designating a permanent room or space is
located on door.

Relocate sign at latch side of door at 60" o.c. above
fish floor.
• As-Built Description:
• Proposed Solution:
3584
2011-12
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3585
2011-12 CSAS 1115B.6
Severity 3
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
18 South Side Unisex Restroom
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07ANT 1 JOB $150 $150
Sign designating a permanent room or space is
located on door.

Relocate sign at latch side of door at 60" o.c. above
fish floor.
• As-Built Description:
• Proposed Solution:
3599
2011-12
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4555, Packet Page 4760 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3600
2011-12 CSAS 1115B.6
Severity 3
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
19 Women's Locker and Shower Room
Drinking Fountain
Project Year:

Funding source:

Project:
602.6
1 JOB $75 $75
1" high
PCODE IA03D Drinking fountain water flow less than 4" high; unit in good condition.

Adjust water flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
3617
2011-12
ADAAG 4.15.3
CSAS 1115B.4.6.5
Severity 2
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3616
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
Signage
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10D 2 JOB $90 $180
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT ROUTE" sign at
door.
• As-Built Description:
• Proposed Solution:
3619
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4556, Packet Page 4761 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-1
Monterey Sports Center Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3613
2011-12
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3614
2011-12 CSAS 1115B.6
Severity 3
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
Total Costs for Floor: Ground Floor $28,535.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4557, Packet Page 4762 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
1 Corridor to Studio 2
Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain is provided per floor: Fountain is not accessible to individuals who
use wheelchairs, or to those who have difficulty
bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
3634
2011-12
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3635
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
2 Studio 2
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 2 JOB $50 $100
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3636
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10B 2 JOB $90 $180
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
3637
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 2
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
3 Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4558, Packet Page 4763 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3641
2011-12
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
4 Sports Center Manager Offices
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07 4 JOB $50 $200
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
3649
2011-12
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 4
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
3650
2011-12
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 4
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
6 Restroom at Kitchen
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3664
2011-12
ADAAG 4.1.3(16)(a)
Severity 3
Priority 4
ADA-2010
General Fund
Sports Center ADA Compliance
Upgrades
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4559, Packet Page 4764 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3663
2011-12 CSAS 1115B.6
Severity 3
Priority 5
General Fund
Sports Center ADA Compliance
Upgrades
Total Costs for Floor: Second Floor $5,840.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4560, Packet Page 4765 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
136-1-2
Monterey Sports Center Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 301 E. Franklin St. CIP - General Fund
Total Costs for Part: Interior $34,375.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4561, Packet Page 4766 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-0-1
Harbor Master Building Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
1 Entrance to Harbor Master Building
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

3.9%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6167
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 1
ADA-2010
Marina Fund
TBD
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07CNT 1 JOB $250 $250
No u-pull provided at change machine cover.

Provide u-pull on change machine cover.
• As-Built Description:
• Proposed Solution:
6168
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 4
ADA-2010
Marina Fund
TBD
Reach Range
Project Year:

Funding source:

Project:
308.2.1
1 JOB $400 $400
53" - 63" AFF
PCODE IE01 Reach height to internet weather kiosk/touch screen, where only forward approach is available,
exceeds 48" or is less than 15".

Modify equipment or mounting.
• As-Built Description:
• Proposed Solution:
• As-Built:
6169
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 1
ADA-2010
Marina Fund
TBD
2 Drinking Fountain Adjacent to Restrooms
Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain is provided per floor: Fountain is not accessible to individuals who
use wheelchairs, or to those who have difficulty
bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
6171
TBD
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
602.2
1 JOB $3,200 $3,200
16" high

9.5" deep
PCODE IA02 Wall- and post-mounted cantilevered units: Knee space not provided at drinking fountain (27" high,
8" deep, 30" wide from front of drinking fountain).

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
6170
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4562, Packet Page 4767 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-0-1
Harbor Master Building Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Project Year:

Funding source:

Project:
602.4
REF

37.5" AFG
PCODE IA03BREF Drinking fountain bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
6172
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
3 POT from Public Restrooms to Marina Restrooms
Handrail
Project Year:

Funding source:

Project:
40 LF $120 $4,800

5.5" openings
PCODE ED08A Open guards does not have balusters or ornamental patterns such that a 4-inch-diameter (102 mm)
sphere cannot pass through any opening.

Provide new guards which do not allow passage of
an 4 inch sphere at any opening.
• As-Built Description:
• Proposed Solution:
• As-Built:
6176
TBD CSAS 1013.3
Severity 3
Priority 4
Marina Fund
TBD
Slope
Project Year:

Funding source:

Project:
403.3
80 SF $25 $2,000

2.3% - 4.9%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6175
TBD
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 2
ADA-2010
Marina Fund
TBD
Walk
Project Year:

Funding source:

Project:
403.3
48 SF $25 $1,200

8.9%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6173
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
303.1
PCODE EF10REF REF
Around utility boxes: Irregular surface in pavement
around utility boxes.

Smooth pavement surface; grind or refinish surface.
• As-Built Description:
• Proposed Solution:
6174
TBD
ADAAG 4.5.2
CSAS 1133B.7.1
Severity 3
Priority 2
ADA-2010
Marina Fund
TBD
4 POT from Restrooms to South Tier Gate
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4563, Packet Page 4768 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-0-1
Harbor Master Building Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6177
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
Marina Fund
TBD
Slope
Project Year:

Funding source:

Project:
405.2
400 SF $100 $40,000

9.9% - 10.2%
PCODE EB02 Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
6178
TBD
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 4
Priority 2
ADA-2010
Marina Fund
TBD
5 South Tier Gate and Ramp
Change in Direction
Project Year:

Funding source:

Project:
405.7.4
30 SF $45 $1,350
48" - 68"
PCODE EB08 Upper landing at change of direction not at least 60"x60" (CA only: 72"x width of ramp runs).

Modify ramp upper landing to 72" length.
• As-Built Description:
• Proposed Solution:
• As-Built:
6184
TBD
ADAAG 4.8.4(3)
CSAS 1133B.5.4
Severity 2
Priority 1
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
405.7.4
30 SF $45 $1,350
68"
PCODE EB08 Lower landing at change of direction not at least 60"x60" (CA only: 72"x width of ramp runs).

Modify ramp lower landing to 72" length.
• As-Built Description:
• Proposed Solution:
• As-Built:
6185
TBD
ADAAG 4.8.4(3)
CSAS 1133B.5.4
Severity 4
Priority 1
ADA-2010
Marina Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6181
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4564, Packet Page 4769 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-0-1
Harbor Master Building Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6180
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
PCODE ID24 1 JOB $500 $500
Front approach: At push side, door does not have
clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Change door swing.
• As-Built Description:
• Proposed Solution:
6182
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 1
ADA-2010
Marina Fund
TBD
Gate
Project Year:

Funding source:

Project:
404.2.10
1 JOB $180 $180

6.5" from ground
PCODE ID06B 10" min. kick-plate/accessible operating hardware at gate not provided on push-side of gate and/or
gap between floor surface and bottom of gate
exceeds 3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
• As-Built:
6179
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Handrail
Project Year:

Funding source:

Project:

REF
15" openings
PCODE ED08AREF Open guards along marina do not have balusters or ornamental patterns such that a 4-inch-diameter
(102 mm) sphere cannot pass through any opening.

Provide new guards which do not allow passage of
an 4 inch sphere at any opening.
• As-Built Description:
• Proposed Solution:
• As-Built:
6190
TBD CSAS 1013.3
Severity 1
Priority 4
Marina Fund
TBD
Slope
Project Year:

Funding source:

Project:
405.2
1 JOB $100 $100

15.9%
PCODE EB02NT Slope greater than 1:12 (8.3%) due to tide adjusting.

Modify connector piece when remodeling.
• As-Built Description:
• Proposed Solution:
• As-Built:
6183
TBD
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 2
Priority 1
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4565, Packet Page 4770 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-0-1
Harbor Master Building Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06 4 JOB $170 $680
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
6187
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
2 JOB $170 $340
9" extensions
PCODE ED05 Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6188
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 52 LF $9 $468
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
6186
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
Marina Fund
TBD
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
5 LF $100 $500
55" AFF
PCODE EG01A Overhead clearance less than 80" above finished floor under ramp.

Provide chain to mark area of low clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6189
TBD
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 1
ADA-2010
Marina Fund
TBD
Total Costs for Floor: On-Site $60,368.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4566, Packet Page 4771 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-0-1
Harbor Master Building Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Total Costs for Part: Exterior $60,368.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4567, Packet Page 4772 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
1 Main Entrance Lobby
Clearance
Project Year: