2.75" to wall
PCODE ED04REF Handrail: Clearance to wall is not 1-1/2".

Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6198
TBD
ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 1
Priority 1
ADA-2010
Marina Fund
TBD
Cross Section
Project Year:

Funding source:

Project:
505.7
36 LF $75 $2,700

2.5"
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6199
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
Marina Fund
TBD
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07C 2 JOB $250 $500
Non-common use areas within this facility, such as
offices, do not have accessible door hardware.

Provide lever handle or other accessible hardware
when a specific need is identified in the future or
when altering area.
• As-Built Description:
• Proposed Solution:
6192
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door to staff area on accessible
route, bottom 10" does not have a smooth,
uninterrupted surface (required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6193
TBD
CSAS 1133B.2.6
Severity 3
Priority 5
ADA-2010
Marina Fund
TBD
Elevator
Project Year:

Funding source:

Project:

PCODE IK01 1 JOB ? $200,000 Elevator not provided in multistory building.

Provide new elevator, or provide alternate access to
city provided services and/or programs. As interim
solution: Signage and phone are provided in down
stairs lobby.
• As-Built Description:
• Proposed Solution:
6191
TBD
ADAAG 4.1.3(5)
CSAS 1007.2.1
Severity 3
Priority 1 Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4568, Packet Page 4773 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Stairway
Project Year:

Funding source:

Project:

PCODE II02D 48 LF $36 $1,728 Stair does not have closed risers.

Modify stair to have closed risers.
• As-Built Description:
• Proposed Solution:
6196
TBD
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 3
Priority 1 Marina Fund
TBD
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06REF 2 REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
6197
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
PCODE EG01A 6 LF $15 $90
Beneath stairs: Overhead clearance less than 80"
above finished floor.

Provide chain to mark area of low clearance.
• As-Built Description:
• Proposed Solution:
6194
TBD
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 1
ADA-2010
Marina Fund
TBD
2 Men's Public Restroom
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
63" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6207
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
1 JOB $2,600 $2,600
29" clear opening width
PCODE ID01 Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6209
TBD
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4569, Packet Page 4774 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6202
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
42" from face of door to wall
PCODE ID23REF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6204
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
404.2.4
REF
Door width + 6.5"
PCODE ID24REF Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6203
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6208
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 41" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6206
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4570, Packet Page 4775 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01A 1 JOB $35,000 $35,000 Multiple accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide accessible restroom with
one accessible stall, lavatory (and one urinal at
Men's).
• As-Built Description:
• Proposed Solution:
6195
TBD
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 3
ADA-2010
Marina Fund
TBD
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
6201
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6200
TBD CSAS 1115B.6
Severity 3
Priority 5
Marina Fund
TBD
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
40" wide
PCODE WB06REF Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
• As-Built:
6205
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
3 Women's Public Restroom
Accessories
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150

43.5" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
6217
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4571, Packet Page 4776 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
56" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6218
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
30" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6213
TBD
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6219
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
41" from face of door to wall
PCODE ID23REF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6214
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
404.2.4
REF
Door width + 7"
PCODE ID24REF Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6212
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4572, Packet Page 4777 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 42" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6215
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01A 1 JOB $35,000 $35,000 Multiple accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide accessible restroom with
one accessible stall, lavatory (and one urinal at
Men's).
• As-Built Description:
• Proposed Solution:
6211
TBD
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 3
ADA-2010
Marina Fund
TBD
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6210
TBD CSAS 1115B.6
Severity 3
Priority 5
Marina Fund
TBD
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
42" wide
PCODE WB06REF Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
• As-Built:
6216
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
4 Men's Marina Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4573, Packet Page 4778 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
43" AFF
36" to 48" from back wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6227
TBD
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
56" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6231
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
56" AFF
PCODE WG03A Accessible coat hook at shower not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6234
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6220
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6223
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4574, Packet Page 4779 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
42" from face of door to wall
PCODE ID23NT Front approach: At pull side, shower door does not have clear and level maneuvering space measuring
door width plus 18" x 60" (CA only: exterior door
width plus 24").

Remove door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6235
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
404.2.4
1 JOB $2,600 $2,600
36" to corner wall
PCODE ID24B Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide relocated new door and frame; remodel
walls as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6224
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Stall door width + 17" to lavatory
counter
PCODE ID24NT Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
6226
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 51" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6228
TBD
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 41" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6229
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4575, Packet Page 4780 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Operable Part
Project Year:

Funding source:

Project:
309.4
PCODE IC02 2 JOB $300 $600
Operable part(s) at fan switch/timer require tight
grasping, pinching, or twisting of the wrist with one
hand.

Modify or replace the operable part(s) to not require
tight grasping, pinching, or twisting of the wrist
with one hand.
• As-Built Description:
• Proposed Solution:
6239
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 42" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6236
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Shower
Project Year:

Funding source:

Project:
1 JOB $500 $500
38" from rear of seat
PCODE WF05B CA only: Mounting height of shower spray bracket exceeds 48" max. or is more than 27" from rear
edge of folding seat.

Provide or remount shower spray bracket within
27" from rear edge of seat.
• As-Built Description:
• Proposed Solution:
• As-Built:
7017
TBD CSAS 1115B.4.4.5.3
Severity 1
Priority 5
Marina Fund
TBD
Project Year:

Funding source:

Project:
608.5
PCODE WF13 2 JOB $700 $1,400 Single lever faucet controls not provided in shower.

Provide new single lever faucet controls.
• As-Built Description:
• Proposed Solution:
6237
TBD
ADAAG 4.27.4
CSAS 1115B.4.4.4.3
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
6222
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4576, Packet Page 4781 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6221
TBD CSAS 1115B.6
Severity 3
Priority 5
Marina Fund
TBD
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6230
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to shower not self closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6232
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upull on inside of stall door. • As-Built Description:
• Proposed Solution:
6225
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Shower stall door does not have accessible
operating hardware (U-pulls on both sides, flip-over
or sliding lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
6233
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4577, Packet Page 4782 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
1 JOB $75 $75
76" AFF
PCODE EG01NT Overhead clearance less than 80" above finished floor.

Modify overhead clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6238
TBD
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
5 Women's Marina Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
31" - 41"
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6249
TBD
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Coat Hook
Project Year:

Funding source:

Project:
603.4
3 JOB $50 $150
53" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6248
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6242
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6243
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4578, Packet Page 4783 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
42" from face of door to wall
PCODE ID23 Front approach: At pull side, shower door does not have clear and level maneuvering space measuring
door width plus 18" x 60" (CA only: exterior door
width plus 24").

Remove door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6251
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 5"
PCODE ID24C Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
6244
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Grab Bars
Project Year:

Funding source:

Project:
609.3
REF
TPD: 8" above SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6250
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
Operable Part
Project Year:

Funding source:

Project:
309.4
PCODE IC02 2 JOB $300 $600
Operable part(s) of light switch and fan timer
require tight grasping, pinching, or twisting of the
wrist with one hand.

Modify or replace the operable part(s) to not require
tight grasping, pinching, or twisting of the wrist
with one hand.
• As-Built Description:
• Proposed Solution:
6254
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 40" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6245
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4579, Packet Page 4784 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Shower
Project Year:

Funding source:

Project:
608.5
PCODE WF13 1 JOB $700 $700
Single lever faucet controls not provided in shower
at side wall.

Provide new single lever faucet controls.
• As-Built Description:
• Proposed Solution:
6252
TBD
ADAAG 4.27.4
CSAS 1115B.4.4.4.3
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
6241
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6240
TBD CSAS 1115B.6
Severity 3
Priority 5
Marina Fund
TBD
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6246
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
Marina Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
6247
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4580, Packet Page 4785 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-1
Harbor Master Building Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
6253
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Marina Fund
TBD
Total Costs for Floor: Ground Floor $293,643.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4581, Packet Page 4786 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-2
Harbor Master Building Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
1 Office or Lobby
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.

Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
6255
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6256
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Public Counter
Project Year:

Funding source:

Project:
904.4
1 JOB $150 $150

41.5" AFF
PCODE IN03 Service counter (stand-up): Accessible section min. 36" length and 36" max. height (in CA: 28" to 34"
high) not provided.

Provide auxiliary shelf, clipboard, or table as
equivalent facilitation.
• As-Built Description:
• Proposed Solution:
• As-Built:
6257
TBD
ADAAG 7.2(2)
CSAS 1122B.4
Severity 3
Priority 1
ADA-2010
Marina Fund
TBD
Sink
Project Year:

Funding source:

Project:
606.2
PCODE IN06AREF REF
Sink does not have knee space min. 27" high x 19"
deep x 30" wide.

Remodel sink when renovating building.
• As-Built Description:
• Proposed Solution:
6258
TBD
ADAAG 4.24.3
CSAS 1115B.4.7.1
Severity 2
Priority 4
ADA-2010
Marina Fund
TBD
Total Costs for Floor: Second Floor $425.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4582, Packet Page 4787 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
118-1-2
Harbor Master Building Part: Interior Floor: Second Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte & Figuero CIP - General Fund
Total Costs for Part: Interior $294,068.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4583, Packet Page 4788 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
1 Accessible Parking Serving Museum
Changes in Level
Project Year:

Funding source:

Project:
403.4
4 SF $21 $84

0.5" lip at bottom of walk
PCODE EF03 Walk: Pavement dislocation creates abrupt change in level exceeding 1/2" in accessible route.

Remove, replace or repair area of pavement
sufficient to correct abrupt change in level.
• As-Built Description:
• Proposed Solution:
• As-Built:
6612
2011-12
ADAAG 4.3.8
CSAS 1133B.7.4
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
Street and Parking Lot
Resurfacing
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
20 SF $12 $240

3.2% - 5.4%
PCODE EA05 Portion of accessible parking space has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
• As-Built:
6610
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
Street and Parking Lot
Resurfacing
Parking
Project Year:

Funding source:

Project:
502.3
1 JOB $200 $200

6.5' wide
PCODE EA02B Accessible parking space does not have 5' wide access aisle; 8' wide for van accessible aisle (CA
only: aisle spaces need to be 18' in length).

Modify parking aisle(s) to create accessible space
by restriping.
• As-Built Description:
• Proposed Solution:
• As-Built:
6609
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
Street and Parking Lot
Resurfacing
Project Year:

Funding source:

Project:
502.3
PCODE EA02BNT 1 JOB $200 $200
Existing striping within access aisle is not diagonal.

Re-stripe access aisle per requirements.
• As-Built Description:
• Proposed Solution:
6606
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
Street and Parking Lot
Resurfacing
Total Costs for Floor: On-Site $724.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4584, Packet Page 4789 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Total Costs for Part: Exterior $724.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4585, Packet Page 4790 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
1 Accessible Parking Serving Museum
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 6 LF $27 $162
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6611
TBD
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 POM - Presidio of Monterey
TBD
Identification
Project Year:

Funding source:

Project:
502.6
PCODE EA04B 1 JOB $315 $315
Sign for accessible parking space is missing or noncompliant.

Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
6605
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
6608
TBD CSAS 1129B.4
Severity 4
Priority 5
POM - Presidio of Monterey
TBD
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
6607
TBD CSAS 1129B.4
Severity 4
Priority 5
POM - Presidio of Monterey
TBD
2 Sloped Concrete Walkway to Museum and Restroom Building Picnic Area
Project Year:

Funding source:

Project:

PCODE NH02NT 1 JOB $100 $100
Single fixed picnic table is not connected to an
outdoor recreation access route.

Relocate to accessible location.
• As-Built Description:
• Proposed Solution:
6616
TBD
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4586, Packet Page 4791 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Picnic Table
Project Year:

Funding source:

Project:
902.2
1 JOB $450 $450
9" deep
PCODE NH11A Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6617
TBD
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
Slope
Project Year:

Funding source:

Project:
403.3
56 SF $25 $1,400

2.3% - 3.3%
PCODE EF07 Cross slope more than 1/4":12" (2%) at lower half of lower run.

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6613
TBD
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Walk
Project Year:

Funding source:

Project:
403.3
56 SF $25 $1,400

5.4% - 6.3%
PCODE EF01 Walk at upper half of lower run: Slope greater than 1:20 (5.0%), and walk does not comply with
requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6614
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Project Year:

Funding source:

Project:
403.3
240 SF $25 $6,000

5.2% - 6.1%
PCODE EF01 Walk at upper run: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for
ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6615
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
3 POT from Sloped Concrete Walk Along Restroom Building Drinking Fountain
Project Year:

Funding source:

Project:
602.4
1 JOB $3,200 $3,200
37" AFG
PCODE IA03B Drinking fountain bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
6619
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4587, Packet Page 4792 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Project Year:

Funding source:

Project:
602.2
1 JOB $2,220 $2,220

4.6% within clear space
PCODE IA06NT 30" wide x 48" long clear floor space not provided at drinking fountain.

Provide clear floor space at drinking fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
6620
TBD
ADAAG 4.15.5(1)*
CSAS 1115B.4.6.3
Severity 2
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
Utility box adjacent to women's
restroom: 8" protrusion at 44" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6621
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Slope
Project Year:

Funding source:

Project:
403.3
45 SF $25 $1,125

2.3% - 3.0%
PCODE EF07 Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6618
TBD
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
4 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
TPD: 36" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6630
TBD
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 4
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Project Year:

Funding source:

Project:

REF
TPD: 5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6628
TBD
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4588, Packet Page 4793 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
15 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6624
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6623
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Electrical
Project Year:

Funding source:

Project:
308.2.1 & 308.2.2
1 JOB $300 $300
52" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.

Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6625
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 4
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 13" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6627
TBD
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Project Year:

Funding source:

Project:
609.3
REF
TPD: 3" above SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6629
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4589, Packet Page 4794 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 36" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6626
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6622
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
5 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
TPD: 46" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
6637
TBD
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 2
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Door
Project Year:

Funding source:

Project:
404.2.4
25 SF $40 $1,000

2.4%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6632
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4590, Packet Page 4795 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
12 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6633
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6634
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Electrical
Project Year:

Funding source:

Project:
308.2.1 & 308.2.2
1 JOB $300 $300
52" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.

Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6639
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 4
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 15" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6638
TBD
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Project Year:

Funding source:

Project:
609.3
REF
TPD: 3" above SGB
PCODE WB07IREF Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6636
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4591, Packet Page 4796 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 36" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6635
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6631
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
POM - Presidio of Monterey
TBD
6 Accessible Ramp to Museum Entrance
Cross Section
Project Year:

Funding source:

Project:
505.7
55 LF $75 $4,125
2"
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6640
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
6643
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Slope
Project Year:

Funding source:

Project:
405.7.1
24 SF $100 $2,400

2.7%
PCODE EB05A Level 2% max. bottom landing for ramp not
provided.

Rebuild ramp to provide landings for each ramp run
with slopes no greater than 2%
• As-Built Description:
• Proposed Solution:
• As-Built:
6642
TBD
ADAAG 4.8.4
CSAS 1133B.5.4.1
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4592, Packet Page 4797 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
REF
0" - 10" extensions
PCODE ED05REF Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6641
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 2
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
7 Stairs to Accessible Parking Space
Cross Section
Project Year:

Funding source:

Project:
505.7
48 LF $75 $3,600
2"
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6644
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
9" - 10" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6645
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
8 Stairs to Museum Main Entrance
Cross Section
Project Year:

Funding source:

Project:
505.7
22 LF $75 $1,650
2"
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6646
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4593, Packet Page 4798 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
10" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6647
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
9 Stairs to Bench Area
Accessible Route
Project Year:

Funding source:

Project:
206.1
PCODE EF13 400 LF $45 $18,000 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

Provide new 48" wide walk / sidewalk.
• As-Built Description:
• Proposed Solution:
6651
TBD
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
Cross Section
Project Year:

Funding source:

Project:
505.7
22 LF $75 $1,650
2"
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
6648
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
Fixed Bench
Project Year:

Funding source:

Project:
903.2
PCODE NO07 1 JOB $500 $500
Clear floor or ground space (30" x 48") not
overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide path and position clear floor or ground
space to allow wheelchair users to be seated
shoulder-to-shoulder with an individual seated on
the bench.
• As-Built Description:
• Proposed Solution:
6650
TBD
ADAAG 4.32.2
CSAS 1118B.4
Severity 2
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4594, Packet Page 4799 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
10" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
6649
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 4
Priority 2
ADA-2010
POM - Presidio of Monterey
TBD
Total Costs for Floor: On-Site $51,802.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4595, Packet Page 4800 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-0-1
Lower Presidio Museum Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Total Costs for Part: Exterior $51,802.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4596, Packet Page 4801 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-1-1
Lower Presidio Museum Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
1 Museum Main Entrance
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6653
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $230 $230

3.5"
PCODE ID02ANT Door inaccessible due to threshold or step at door exceeding 3/4".

Provide directional sign at stair to guide persons to
accessible entrance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6652
TBD
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 1
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
2 Accessible Entrance
Carpet/Doormat
Project Year:

Funding source:

Project:
302.2
PCODE ID05A 1 JOB $75 $75
Doormat not securely attached to ground or floor
structure.

Attach doormat to floor surface or remove doormat.
• As-Built Description:
• Proposed Solution:
6657
TBD
ADAAG 4.5.3
CSAS 1124B.3
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
12 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6656
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Signage
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10B 1 JOB $90 $90
At door leading into exit stairway: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT STAIR
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
6655
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4597, Packet Page 4802 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-1-1
Lower Presidio Museum Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Project Year:

Funding source:

Project:
216.4.1
PCODE SA10C 1 JOB $90 $90
At door leading into exit ramp: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.

Provide raised letter/Braille "EXIT RAMP
UP/DOWN" sign at door.
• As-Built Description:
• Proposed Solution:
6654
TBD
ADAAG 4.1.3(16)
CSAS 1011.3
Severity 3
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
3 Museum and Culture Offices
Non-Fixed Desk
Project Year:

Funding source:

Project:
306.1
1 JOB $1,600 $1,600
Guest sign in & donation box: 36" AFF
PCODE IN02ANT Accessible non-fixed table or desk (top 28" to 34" high; knee space at least 27" high x 19" deep x 30"
wide) not provided.

Provide table or desk with accessible dimensions
when purchasing new furniture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6658
TBD
ADAAG 4.32.3 & .4
CSAS 1122B.3 & 4
Severity 2
Priority 1
ADA-2010
POM - Presidio of Monterey
TBD
Total Costs for Floor: Ground Floor $2,135.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4598, Packet Page 4803 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
128-1-1
Lower Presidio Museum Part: Interior Floor: Ground Floor City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Presidio of Monterey CIP - General Fund
Total Costs for Part: Interior $2,135.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4599, Packet Page 4804 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-0-1
Wharf I Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
1 POT from Women's Restroom to California Dock
Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain is provided per floor: Fountain is not accessible to individuals who
use wheelchairs, or to those who have difficulty
bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
5861
TBD
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
602.4
REF

37.5" AFG
PCODE IA03BREF Drinking fountain by restroom bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
5860
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain by restroom not located in an alcove (min. 32" wide x 18" deep) or
otherwise encroaches into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
5859
TBD 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
Wharves 1 & 2 Fund
TBD
Total Costs for Floor: On-Site $5,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4600, Packet Page 4805 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-0-1
Wharf I Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Total Costs for Part: Exterior $5,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4601, Packet Page 4806 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
1 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
2 JOB $100 $200
SD: 44" AFF
SCD: 48" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5872
TBD CSAS 1115B.8.3
Severity 2
Priority 5
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5875
TBD
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 Wharves 1 & 2 Fund
TBD
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
60" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5877
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door
Project Year:

Funding source:

Project:
404.2.4
REF

4.2%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
5866
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Door width + 3.5"
PCODE ID23NT Front approach: At pull side, stall door does not have clear and level maneuvering space measuring
door width plus 18" x 60" (CA only: exterior door
width plus 24").

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
5873
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4602, Packet Page 4807 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 43" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5874
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
609.3
PCODE WB07IREF REF
Toilet paper dispenser and seat cover dispenser in
accessible stall located closer than 1-1/2" below or
18" above grab bar impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
5876
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 2 JOB $120 $240
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
5871
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 36" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5870
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:

PCODE SA07CREF REF
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.

CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
5868
TBD CSAS 1117B.5.6
Severity 3
Priority 3
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4603, Packet Page 4808 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5867
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
1 JOB $90 $90
New sign is not on door.

PCODE SA15NT Required in CA only: identification symbol centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
• As-Built:
5869
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5878
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
2 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
2 JOB $100 $200
SD: 43" AFF
SCD: 46" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5886
TBD CSAS 1115B.8.3
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4604, Packet Page 4809 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Project Year:

Funding source:

Project:

REF

5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
5892
TBD
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
41" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
5885
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door
Project Year:

Funding source:

Project:
404.2.4
REF

3.8%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
5882
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $500 $500
Door width + 3"
PCODE ID23NT Front approach: At pull side, stall door does not have clear and level maneuvering space measuring
door width plus 18" x 60" (CA only: exterior door
width plus 24").

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
5888
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 43" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5891
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4605, Packet Page 4810 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Project Year:

Funding source:

Project:
609.3
REF
9" above GB
PCODE WB07IREF Toilet paper dispenser and seat cover dispenser in accessible stall located closer than 1-1/2" below or
18" above grab bar impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
5893
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5887
TBD
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
606.5
PCODE WD05 2 JOB $120 $240
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
5883
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 36" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5884
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
BCS: 19" protrusion at 36" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5889
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4606, Packet Page 4811 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Semi-Ambulant Stall
Project Year:

Funding source:

Project:
213.3.1
PCODE WB06A 1 JOB $1,900 $1,900 Semi-Ambulant stall with 36" width, parallel grab bars, and out-swinging door not provided (one
required where 6 or more exist).

Provide 36" wide stall with out-swinging door and
two side grab bars. Remodel restroom as needed.
• As-Built Description:
• Proposed Solution:
5879
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5880
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5881
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5890
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Total Costs for Floor: Ground Floor $7,020.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4607, Packet Page 4812 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-1-1
Wharf I Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Total Costs for Part: Interior $7,020.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4608, Packet Page 4813 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-0-1
Wharf II Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
1 A-Tier Dock's Ramp
Door
Project Year:

Funding source:

Project:

PCODE ID06 1 JOB $100 $100
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Provide 10" min. "kick plate" covering width of
door when altering area.
• As-Built Description:
• Proposed Solution:
6158
TBD CSAS 1133B.2.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
20 lbs
PCODE ID03 Excessive force required to open gate.

Adjust regular gate closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6159
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 1
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Slope
Project Year:

Funding source:

Project:
405.2
180 SF $100 $18,000

20.8%
45 LF
PCODE EB02NT Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails. Interim solution: provide directional sign
to accessible boarding location.
• As-Built Description:
• Proposed Solution:
• As-Built:
6160
TBD
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 1
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
PCODE ED05 4 JOB $170 $680
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
6161
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
2 H-Tier Dock's Ramp
Change in Direction
Project Year:

Funding source:

Project:
405.7.4
PCODE EB08REF REF
Landing at change of direction not at least
60"x60" (CA only: 72"x width of ramp runs).

Modify ramp bottom landing to 72" length.
• As-Built Description:
• Proposed Solution:
6165
TBD
ADAAG 4.8.4(3)
CSAS 1133B.5.4
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4609, Packet Page 4814 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-0-1
Wharf II Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Door
Project Year:

Funding source:

Project:

PCODE ID06 1 JOB $100 $100
At push side of gate on accessible route, bottom 10"
does not have a smooth, uninterrupted surface
(required in CA only).

Provide 10" min. "kick plate" covering width of
door when altering area.
• As-Built Description:
• Proposed Solution:
6162
TBD CSAS 1133B.2.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
15 lbs
PCODE ID03 Excessive force required to open gate.

Adjust regular gate closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6163
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Slope
Project Year:

Funding source:

Project:
405.2
180 SF $100 $18,000

20.8%
45 LF
PCODE EB02NT Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails. Interim solution: provide directional sign
to accessible boarding location.
• As-Built Description:
• Proposed Solution:
• As-Built:
6164
TBD
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 1
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
PCODE ED05 4 JOB $170 $680
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
6166
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Total Costs for Floor: On-Site $37,610.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4610, Packet Page 4815 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-0-1
Wharf II Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Total Costs for Part: Exterior $37,610.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4611, Packet Page 4816 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-1-1
Wharf II Part: Beach Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
1 POT Along West Side of Restroom
Accessible Route
Project Year:

Funding source:

Project:
22 LF $45 $990
6"
PCODE EG08NT (CA requirement only) Abrupt changes in level, except between a walk or sidewalk and an adjacent
street or driveway, exceeding 4" in depth must be
identified by a 6" min. curb above the potential
drop off.

Extend walkway 6" to sand and provide curb
between walkway and sand.
• As-Built Description:
• Proposed Solution:
• As-Built:
6021
TBD CSAS 1133B.8.1
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 18 LF $27 $486
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6015
TBD
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 Wharves 1 & 2 Fund
TBD
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01 4 LF $95 $380
Handrail not provided at step at Porto Potty,
required on both sides (not required at curb ramps
or adjacent to seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
6018
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Nosings
Project Year:

Funding source:

Project:
504.5
PCODE EC01 6 LF $20 $120
Stair nosings project more than 1-1/2" past face of
riser and/or are not beveled on underside 60° min.
from horizontal.

Modify stair nosings.
• As-Built Description:
• Proposed Solution:
6017
TBD
ADAAG 4.9.3
CSAS 1133B.4.5.2
Severity 4
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4612, Packet Page 4817 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-1-1
Wharf II Part: Beach Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage at step sufficient to guide persons
to accessible entrances.
• As-Built Description:
• Proposed Solution:
6019
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Slope
Project Year:

Funding source:

Project:
403.3
88 SF $25 $2,200

2.7% - 3.2%
PCODE EF07 Cross slope more than 1/4":12" (2%) at area in front of restroom entrance.

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
6020
TBD
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
Vertical Clearance
Project Year:

Funding source:

Project:
307.4
6 LF $100 $600
Pump valves: 33" AFF
PCODE EG01A Overhead clearance less than 80" above finished floor.

Provide cane-detectable railing to mark area of low
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
6016
TBD
ADAAG 4.4.2
CSAS 1133B.8.6.2
Severity 2
Priority 1
ADA-2010
Wharves 1 & 2 Fund
TBD
2 Women's Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF

28.5" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6023
TBD
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01A 1 JOB $35,000 $35,000 Multiple accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide accessible restroom with
one accessible stall, lavatory (and one urinal at
Men's).
• As-Built Description:
• Proposed Solution:
6022
TBD
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4613, Packet Page 4818 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-1-1
Wharf II Part: Beach Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6026
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6025
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
34" wide
PCODE WB06REF Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
• As-Built:
6024
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
3 Men's Restroom
Door Clearance
Project Year:

Funding source:

Project:
404.3.1
REF
21" clear opening width
PCODE ID01REF Door on accessible route has less than 32" clear opening width when 90° open (CA only:...or has
leaf size less than 36" wide or 80" high).

Provide new, larger door and frame with new
accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
6030
TBD
ADAAG 4.13.5
CSAS 1133B.1.1.1.1
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4614, Packet Page 4819 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-1-1
Wharf II Part: Beach Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Restroom
Project Year:

Funding source:

Project:
603
PCODE WA01A 1 JOB $35,000 $35,000 Multiple accommodation restroom not accessible; multiple compliance violations.

Remodel area to provide accessible restroom with
one accessible stall, lavatory (and one urinal at
Men's).
• As-Built Description:
• Proposed Solution:
6029
TBD
ADAAG 4.22
CSAS 1115B.3.1
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
6027
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6028
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
36" wide
PCODE WB06REF Toilet stall less than 60" wide.

Provide new accessible stall (alternate stalls 36" x
69" or 48" x 69" not recommended).
• As-Built Description:
• Proposed Solution:
• As-Built:
6031
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Total Costs for Floor: Ground Floor $75,366.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4615, Packet Page 4820 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-1-1
Wharf II Part: Beach Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Total Costs for Part: Beach Restroom $75,366.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4616, Packet Page 4821 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-2-1
Wharf II Part: End Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
1 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
4 JOB $100 $400
SD: 42" AFF
EHD: 42" AFF
SCD: 48" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5997
TBD CSAS 1115B.8.3
Severity 2
Priority 5
Wharves 1 & 2 Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
5994
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $50 $50
39" from face of wall to privacy screen
PCODE ID28ANT Latch approach: At push side, door does not have clear and level maneuvering space measuring door
width plus 24" (starting at hinge) x 42", or 48" if
door has closer (CA only: door width plus 24" x
44").

Remove or relocate furniture or storage items.
• As-Built Description:
• Proposed Solution:
• As-Built:
5999
TBD
ADAAG Fig. 25(c)
CSAS 11B-26A(c)
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Extends 53" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6004
TBD
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4617, Packet Page 4822 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-2-1
Wharf II Part: End Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 44.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6003
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.5" knee
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5998
TBD
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6000
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 41" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
5996
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5995
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4618, Packet Page 4823 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-2-1
Wharf II Part: End Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
6002
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Water Closet
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
6001
TBD
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
2 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
308.2.1
3 JOB $100 $300
SD: 48" AFF
EHD: 42" AFF
SCD: 56" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6008
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6013
TBD
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 Wharves 1 & 2 Fund
TBD
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6006
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4619, Packet Page 4824 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-2-1
Wharf II Part: End Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.8.1.5
PCODE WB07 1 JOB $500 $500
Side grab bar not provided or are not code
compliant.

Provide accessible side grab bar.
• As-Built Description:
• Proposed Solution:
6012
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 43.5" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6014
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6009
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 41" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6007
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6005
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4620, Packet Page 4825 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-2-1
Wharf II Part: End Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6011
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
6010
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Total Costs for Floor: Ground Floor $5,085.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4621, Packet Page 4826 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-2-1
Wharf II Part: End Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Total Costs for Part: End Restroom $5,085.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4622, Packet Page 4827 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
1 Men's Restroom
Accessible Compartment
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05D 1 JOB $500 $500
The location of the stall door is not in front of the
clear space (next to the water closet), with a
maximum stile width of 4 ".

Remodel compartment.
• As-Built Description:
• Proposed Solution:
6124
TBD
ADAAG 4.17.3 & Fig. 30(a)
CSAS 1115B.3.1.4.3
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Accessories
Project Year:

Funding source:

Project:

REF
SCD: 48" AFF
PCODE WG01AREF Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6130
TBD CSAS 1115B.8.3
Severity 2
Priority 5
Wharves 1 & 2 Fund
TBD
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
60" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6132
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 4 LF $27 $108
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6116
TBD
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 3 Wharves 1 & 2 Fund
TBD
Door
Project Year:

Funding source:

Project:
404.2.4
REF

9.7%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%) due to ramp.

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6117
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4623, Packet Page 4828 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6134
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door Threshold
Project Year:

Funding source:

Project:
404.2.5
1 JOB $400 $400
1"
PCODE ID02A Door inaccessible due to threshold or step at door exceeding 3/4".

Modify threshold to be no more than 1/2" by
removing existing paving at door and providing
landing with edge ramping (slope 1:20 max).
• As-Built Description:
• Proposed Solution:
• As-Built:
6125
TBD
ADAAG 4.13.8
CSAS 1133B.2.4.1
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 44" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
6131
TBD
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
TPD & SCD: 8" above grab bars
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6127
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.5" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6138
TBD
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4624, Packet Page 4829 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
6137
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Operable Part
Project Year:

Funding source:

Project:
309.4
PCODE IC02 1 JOB $300 $300
Operable part of fan timer require tight grasping,
pinching, or twisting of the wrist with one hand.

Modify or replace the operable part of fan timer to
not require tight grasping, pinching, or twisting of
the wrist with one hand.
• As-Built Description:
• Proposed Solution:
6135
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 40" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6121
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Shower
Project Year:

Funding source:

Project:
608.6
1 JOB $500 $500
43" - 63"
PCODE WF05 Shower spray unit with hose at least 60" long that can be used fixed and hand-held is not provided
(Exception: Where vandalism is a consideration, a
fixed shower head mounted at 48" height is
allowed).

Provide an accessible shower spray unit with hose
(60" minimum length).
• As-Built Description:
• Proposed Solution:
• As-Built:
6136
TBD
ADAAG 4.21.6
CSAS 1115B.4.4.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
6119
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4625, Packet Page 4830 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Project Year:

Funding source:

Project:
703.4.1
REF
69" AFF
PCODE SA07REF Compliant sign identifying permanent room or space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
• As-Built:
6120
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6118
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6122
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upull on inside of stall door. • As-Built Description:
• Proposed Solution:
6123
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4626, Packet Page 4831 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
REF
45" in front of water closet
PCODE WB03REF Less than 59" from back wall to front wall or door swing of toilet stall, or less than 56" if water closet is wall-hung (CA only: Less than 60" wide and 48"
deep from front of water closet to door in front
entry stall).

Provide new enclosure at existing water closet
fixture.
• As-Built Description:
• Proposed Solution:
• As-Built:
6129
TBD
ADAAG 4.17.3
CSAS 1115B.3.4.3
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
54"
PCODE WB06 Toilet stall less than 60" wide.

Provide new accessible stall.
• As-Built Description:
• Proposed Solution:
• As-Built:
6128
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.1
PCODE WB06REF REF
Toilet stall less than 60" wide due to partition
support bar.

Remove support bar and provide alternate
reinforcement.
• As-Built Description:
• Proposed Solution:
6126
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Urinal
Project Year:

Funding source:

Project:
605.2
1 JOB $2,400 $2,400
22" AFF
PCODE WE02 Fixture mounted with rim more than 17" above floor.

Provide accessible urinal. Remodel restroom as
needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
6133
TBD
ADAAG 4.18.2
CSAS 1115B.4.2.1
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Walk
Project Year:

Funding source:

Project:
403.3
30 SF $25 $750

9.7%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6115
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
2 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4627, Packet Page 4832 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Accessible Compartment
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $500 $500
Stile width: 22"
PCODE WB05D The location of the stall door is not in front of the clear space (next to the water closet), with a
maximum stile width of 4 ".

Remodel compartment.
• As-Built Description:
• Proposed Solution:
• As-Built:
6149
TBD
ADAAG 4.17.3 & Fig. 30(a)
CSAS 1115B.3.1.4.3
Severity 1
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Accessories
Project Year:

Funding source:

Project:

REF
SCD: 47" AFF
PCODE WG01AREF Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
6154
TBD CSAS 1115B.8.3
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:

REF
TPD: 5.5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
6152
TBD
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
41" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
6146
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
60" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6150
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4628, Packet Page 4833 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 4 LF $27 $108
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area.
• As-Built Description:
• Proposed Solution:
6144
TBD
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 3 Wharves 1 & 2 Fund
TBD
Door
Project Year:

Funding source:

Project:
404.2.4
REF

6.8%
PCODE ID11REF Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%) due to sloped
walk.

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
6142
TBD
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
6156
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Door Swing
Project Year:

Funding source:

Project:
404.2.4
1 JOB $5,000 $5,000
Door width + 8"
PCODE ID24C Front approach: At push side, door does not have clear and level maneuvering space measuring door
width x 48" (door width plus 12" if door has both,
latch and closer).

Provide door operator.
• As-Built Description:
• Proposed Solution:
• As-Built:
6143
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4629, Packet Page 4834 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
609.3
2 JOB $75 $150
TPD & SCD: 6" above grab bars
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
6153
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.25" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
6145
TBD
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Operable Part
Project Year:

Funding source:

Project:
309.4
PCODE IC02 1 JOB $300 $300
Operable part of fan/light require tight grasping,
pinching, or twisting of the wrist with one hand.

Modify or replace the operable part of fan/light to
not require tight grasping, pinching, or twisting of
the wrist with one hand.
• As-Built Description:
• Proposed Solution:
6157
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
EHD: 10" protrusion at 40" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
6151
TBD
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 2
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07B 1 JOB $150 $150
Sign designating a permanent room or space is not
centered at 60" above the finished floor.

Remount signage to 60" o.c., remodel wall as
needed.
• As-Built Description:
• Proposed Solution:
6141
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4630, Packet Page 4835 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
6140
TBD CSAS 1115B.6
Severity 3
Priority 5
Wharves 1 & 2 Fund
TBD
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
6148
TBD
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upull on inside of stall door. • As-Built Description:
• Proposed Solution:
6147
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
PCODE WB06NT 1 JOB $1,500 $1,500 Toilet stall less than 60" wide due to support bar.

Remove support bar and provide alternate
reinforcement.
• As-Built Description:
• Proposed Solution:
6155
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 3
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Walk
Project Year:

Funding source:

Project:
403.3
30 SF $25 $750

6.8%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
6139
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 3
ADA-2010
Wharves 1 & 2 Fund
TBD
Total Costs for Floor: Ground Floor $19,546.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4631, Packet Page 4836 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
138-3-1
Wharf II Part: Boater's Restroom Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Wharf II CIP - General Fund
Total Costs for Part: Boater's Restroom $19,546.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4632, Packet Page 4837 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-0-1
Wharf I Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
1 POT from Women's Restroom to California Dock
Handrail
Project Year:

Funding source:

Project:
? LF $120 ?

5.5" - 6"
PCODE ED08A Open guards does not have balusters or ornamental patterns such that a 4-inch-diameter (102 mm)
sphere cannot pass through any opening.

Provide new guards which do not allow passage of
an 4 inch sphere at any opening.
• As-Built Description:
• Proposed Solution:
• As-Built:
5862
2011-12 CSAS 1013.3
Severity 3
Priority 3
Wharves 1 & 2 Fund
Wharf 1 Guest Dock Grant Match
2 Aluminum Ramp to Lower Docks
Curb or Barrier
Project Year:

Funding source:

Project:
405.9.2
PCODE EB14 48 LF $17 $816
No curb (2" minimum height) or wheel guide
(centered approx. 3" above surface of ramp) at sides
of ramp.

Provide 2" minimum curb or wheel guide.
• As-Built Description:
• Proposed Solution:
5863
2011-12
ADAAG 4.8.7
CSAS 1133B.5.6
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
Wharf 1 Guest Dock Grant Match
Height
Project Year:

Funding source:

Project:
505.4
48 LF $75 $3,600
42"
PCODE ED02 Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
5864
2011-12
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 1
ADA-2010
Wharves 1 & 2 Fund
Wharf 1 Guest Dock Grant Match
Slope
Project Year:

Funding source:

Project:
405.2
200 SF $65 $13,000

34.0% at low tide
PCODE EB02 Slope greater than 1:12 (8.3%).

Demolish existing and provide new ramp with
handrails.
• As-Built Description:
• Proposed Solution:
• As-Built:
5865
2011-12
ADAAG 4.8.2
CSAS 1133B.5.3
Severity 1
Priority 1
ADA-2010
Wharves 1 & 2 Fund
Wharf 1 Guest Dock Grant Match
Total Costs for Floor: On-Site $17,416.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4633, Packet Page 4838 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-0-1
Wharf I Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Total Costs for Part: Exterior $17,416.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4634, Packet Page 4839 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
137-0-1
Wharf I Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oliver St. CIP - General Fund
Total Costs for Funding: CIP - General Fund $3,303,134.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4635, Packet Page 4840 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. NIP - Neighbor Improvement Plan 6 Community Room
Assistive Listening
Project Year:

Funding source:

Project:
219.1 & 706.1
PCODE GI01DREF REF
No portable assistive listening system provided for
small assembly space/room accommodating at least
50 persons, or having an audio-amplification
system, and with fixed seating.

Provide portable assistive listening system, to be
shared with other spaces/rooms.
• As-Built Description:
• Proposed Solution:
3300
TBD
ADAAG 4.1.3(19)(b) & 4.33.7
CSAS 1104B.2
Severity 3
Priority 2
ADA-2010
Partial/Other Funded
Library Alarm System (CW-63)
Total Costs for Floor: Ground Floor
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4636, Packet Page 4841 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. NIP - Neighbor Improvement Plan Total Costs for Part: Interior
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4637, Packet Page 4842 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-1
Library Part: Interior Floor: Ground Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. NIP - Neighbor Improvement Plan 1 Circulation Area and Main Floor
Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain is provided per floor: Fountain is not accessible to individuals who
use wheelchairs, or to those who have difficulty
bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
3239
TBD
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
Partial/Other Funded
Library Drinking Fountain Upgrade
(CW-59)
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
3240
TBD 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
Partial/Other Funded
Library Drinking Fountain Upgrade
(CW-59)
Total Costs for Floor: Ground Floor $5,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4638, Packet Page 4843 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. NIP - Neighbor Improvement Plan 4 Drinking Fountain at Unisex Restrooms
Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain is provided per floor: Fountain is not accessible to individuals who
use wheelchairs, or to those who have difficulty
bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
3375
TBD
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
Partial/Other Funded
Library Drinking Fountain Upgrade
(CW-59)
Project Year:

Funding source:

Project:
1 JOB $3,000 $3,000

17.5" deep
PCODE IA04NT Drinking fountain alcove is within door clear floor space.

Relocate drinking fountain and provide accessible
alcove (32" wide min. x 18" deep).
• As-Built Description:
• Proposed Solution:
• As-Built:
3376
TBD 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 3
Partial/Other Funded
Library Drinking Fountain Upgrade
(CW-59)
Total Costs for Floor: Second Floor $5,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4639, Packet Page 4844 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. NIP - Neighbor Improvement Plan Total Costs for Part: Interior $10,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4640, Packet Page 4845 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
124-1-2
Library Part: Interior Floor: Second Floor
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 625 Pacific St. NIP - Neighbor Improvement Plan Total Costs for Funding: NIP - Neighbor Improvement Plan $10,000.00 Total Costs for Facility: City of Monterey $3,969,469.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4641, Packet Page 4846 SSA Project # 11037
City of Monterey - ADA Transition Plan
March 2013
City of Monterey Facilities (Parks)
Access Compliance Survey Reports

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4642, Packet Page 4847 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: Building Maintenance $2,400.00
Funding Source: General Fund Project: General Maintenance $2,400.00 Fac #: 1005 Cypress Park $2,400.00
Exterior On-Site $2,400.00
Funding: Building Maintenance $2,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 1 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4643, Packet Page 4848 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: Building Maintenance $224,623.00
Funding Source: General Fund Project: General Maintenance $224,623.00 Fac #: 1001 Archer Park $2,040.00
Exterior On-Site $2,040.00
Fac #: 1004 Casanova Oak Knoll Park $5,225.00
Exterior On-Site $5,225.00
Fac #: 1005 Cypress Park $7,654.00
Exterior On-Site $7,654.00
Fac #: 1006 Deer Flats Park $460.00
Exterior On-Site $460.00
Fac #: 1007 Don Dahvee Park $1,385.00
Exterior On-Site $1,385.00
Fac #: 1008 El Estero Park Complex $42,166.00
Exterior On-Site $42,166.00
Fac #: 1010 Peter J. Ferrante Park $8,023.00
Exterior On-Site $8,023.00
Fac #: 1011 Fisherman Flats Park $230.00
Exterior On-Site $230.00
Fac #: 1012 Hilltop Park $17,159.00
Exterior On-Site $17,159.00
Fac #: 1013 Hoffman Park $10,734.00
Exterior On-Site $10,734.00
Fac #: 1014 Jacks Ball Park $7,890.00
Exterior On-Site $7,890.00
Fac #: 1016 Laguna Grande Regional Park $1,220.00
Exterior On-Site $1,220.00
Fac #: 1019 Larkin Park $2,697.00
Exterior On-Site $2,697.00
Fac #: 1021 Montecito Park $8,950.00
Exterior On-Site $8,950.00
Fac #: 1022 Monterey Bay Park $1,050.00
Exterior On-Site $1,050.00
Fac #: 1023 Oak Newton Park $16,911.00
Exterior On-Site $16,911.00
Fac #: 1027 Ryan Ranch Park $7,617.00
Exterior On-Site $7,617.00
Fac #: 1028 San Carlos Beach Park $13,356.00
Exterior On-Site $13,356.00
Fac #: 1029 Scholze Park $6,226.00
Exterior On-Site $6,226.00
Fac #: 1030 Fisherman's Shoreline Park $24,179.00
Exterior On-Site $24,179.00
Fac #: 1032 Spray Avenue Tot Lot $180.00
Exterior On-Site $180.00
Fac #: 1033 Veterans Memorial Park $10,185.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 2 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4644, Packet Page 4849 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Exterior On-Site $10,185.00
Fac #: 1034 Via Pariaso Park $17,180.00
Exterior On-Site $17,180.00
Fac #: 1035 Whispering Pine Park $11,906.00
Exterior On-Site $11,906.00
Funding: Building Maintenance $224,623.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 3 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4645, Packet Page 4850 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: CIP - General Fund $2,551,745.00
Funding Source: Gas Tax Project: City ADA Transition Plan Upgrade - Intersections $5,800.00 Fac #: 1005 Cypress Park $2,800.00
Exterior On-Site $2,800.00
Fac #: 1010 Peter J. Ferrante Park $3,000.00
Exterior On-Site $3,000.00
Funding Source: Gas Tax Project: Upgrade City Pavement Management Program $88,688.00 Fac #: 1005 Cypress Park $62,800.00
Exterior On-Site $62,800.00
Fac #: 1010 Peter J. Ferrante Park $25,200.00
Exterior On-Site $25,200.00
Fac #: 1019 Larkin Park $688.00
Exterior On-Site $688.00
Funding Source: General Fund Project: City ADA Transition Plan Upgrade $2,243,219.00 Fac #: 1001 Archer Park $93,805.00
Exterior On-Site $93,805.00
Fac #: 1004 Casanova Oak Knoll Park $62,146.00
Exterior On-Site $62,146.00
Fac #: 1005 Cypress Park $59,925.00
Exterior On-Site $59,925.00
Fac #: 1006 Deer Flats Park $34,140.00
Exterior On-Site $34,140.00
Fac #: 1007 Don Dahvee Park $103,032.00
Exterior On-Site $103,032.00
Fac #: 1008 El Estero Park Complex $466,223.00
Exterior On-Site $466,223.00
Fac #: 1010 Peter J. Ferrante Park $67,673.00
Exterior On-Site $67,673.00
Fac #: 1011 Fisherman Flats Park $46,896.00
Exterior On-Site $46,896.00
Fac #: 1012 Hilltop Park $71,564.00
Exterior On-Site $71,564.00
Fac #: 1013 Hoffman Park $50,365.00
Exterior On-Site $50,365.00
Fac #: 1014 Jacks Ball Park $84,246.00
Exterior On-Site $84,246.00
Fac #: 1016 Laguna Grande Regional Park $48,478.00
Exterior On-Site $48,478.00
Fac #: 1017 Laguna Grande Court Park $5,250.00
Exterior On-Site $5,250.00
Fac #: 1019 Larkin Park $36,660.00
Exterior On-Site $36,660.00
Fac #: 1021 Montecito Park $12,735.00
Exterior On-Site $12,735.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 4 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4646, Packet Page 4851 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Fac #: 1022 Monterey Bay Park $40,431.00
Exterior On-Site $40,431.00
Fac #: 1023 Oak Newton Park $159,545.00
Exterior On-Site $159,545.00
Fac #: 1024 Quarry Park $2,850.00
Exterior On-Site $2,850.00
Fac #: 1027 Ryan Ranch Park $39,175.00
Exterior On-Site $39,175.00
Fac #: 1028 San Carlos Beach Park $98,080.00
Exterior On-Site $98,080.00
Fac #: 1029 Scholze Park $118,660.00
Exterior On-Site $118,660.00
Fac #: 1030 Fisherman's Shoreline Park $94,080.00
Exterior On-Site $94,080.00
Fac #: 1032 Spray Avenue Tot Lot $9,315.00
Exterior On-Site $9,315.00
Fac #: 1033 Veterans Memorial Park $292,911.00
Exterior On-Site $292,911.00
Fac #: 1034 Via Pariaso Park $94,888.00
Exterior On-Site $94,888.00
Fac #: 1035 Whispering Pine Park $50,146.00
Exterior On-Site $50,146.00
Funding Source: Parking Fund Project: ADA Transition Plan Improvements $8,116.00 Fac #: 1028 San Carlos Beach Park $8,116.00
Exterior On-Site $8,116.00
Funding Source: Parking Fund Project: Parking Lot Maintenance and Repair $715.00 Fac #: 1028 San Carlos Beach Park $715.00
Exterior On-Site $715.00
Funding Source: POM - Presidio of Monterey Project: Street and Parking Lot Resurfacing $15,932.00 Fac #: 1031 Soldier Field $15,932.00
Exterior On-Site $15,932.00
Funding Source: POM - Presidio of Monterey Project: TBD $189,275.00 Fac #: 1031 Soldier Field $189,275.00
Exterior On-Site $189,275.00
Funding: CIP - General Fund $2,551,745.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 5 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4647, Packet Page 4852 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: NIP - Neighbor Improvement Plan $174,330.00
Funding Source: Cut-Off Projects Project: Dennis the Menace Walkway/Access Improvements PH II (CW-20) $1,100.00 Fac #: 1008 El Estero Park Complex $1,100.00
Exterior On-Site $1,100.00
Funding Source: Cut-Off Projects Project: TBD $4,250.00 Fac #: 1008 El Estero Park Complex $4,250.00
Exterior On-Site $4,250.00
Funding Source: Fully Funded Project: Cypress Park ADA Access to Tot Lot (NM-33) $150,000.00 Fac #: 1005 Cypress Park $150,000.00
Exterior On-Site $150,000.00
Funding Source: Partial/Other Funded Project: El Estero Picnic Area (CW-23) $12,530.00 Fac #: 1008 El Estero Park Complex $12,530.00
Exterior On-Site $12,530.00
Funding Source: Partial/Other Funded Project: Laguna Grande Park Replace Walkway Adjacent to Park Lot (DMG-05) $6,450.00 Fac #: 1016 Laguna Grande Regional Park $6,450.00
Exterior On-Site $6,450.00
Funding: NIP - Neighbor Improvement Plan $174,330.00
Grand Total for City of Monterey $2,953,098.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 6 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4648, Packet Page 4853 City of Monterey Access Compliance Survey Report Cost Summary (By Funding) Funding: Building Maintenance $2,400.00
General Fund $2,400.00
General Maintenance $2,400.00
Funding: Building Maintenance $224,623.00
General Fund $224,623.00
General Maintenance $224,623.00
Funding: CIP - General Fund $2,551,745.00
Gas Tax $94,488.00
City ADA Transition Plan Upgrade - Intersections $5,800.00 Upgrade City Pavement Management Program $88,688.00
General Fund $2,243,219.00
City ADA Transition Plan Upgrade $2,243,219.00
Parking Fund $8,831.00
ADA Transition Plan Improvements $8,116.00
Parking Lot Maintenance and Repair $715.00
POM - Presidio of Monterey $205,207.00
Street and Parking Lot Resurfacing $15,932.00
TBD $189,275.00
Funding: NIP - Neighbor Improvement Plan $174,330.00
Cut-Off Projects $5,350.00
Dennis the Menace Walkway/Access Improvements PH II (CW-20) $1,100.00 TBD $4,250.00
Fully Funded $150,000.00
Cypress Park ADA Access to Tot Lot (NM-33) $150,000.00
Partial/Other Funded $18,980.00
El Estero Picnic Area (CW-23) $12,530.00
Laguna Grande Park Replace Walkway Adjacent to Park Lot (DMG-05) $6,450.00 Grand Total for City of Monterey $2,953,098.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c . Cost summary-Page 1 APPENDIX N Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4649, Packet Page 4854 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
10 Stairs at NW Side of Park
Handrail
Project Year:

Funding source:

Project:
505.7
32 LF $75 $2,400
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2368
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $2,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4650, Packet Page 4855 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
Total Costs for Part: Exterior $2,400.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4651, Packet Page 4856 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
Total Costs for Funding: Building Maintenance $2,400.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4652, Packet Page 4857 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
1 Parking Spaces Serving Archer Park
Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01A 1 JOB $300 $300
At parking lot with 1-25 spaces, the number of
accessible spaces is less than required by code; 1
space required
Provide required accessible parking space with sign
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
2720
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
2719
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
2 POT from Parking Spaces to Play Structure Entrance
Door
Project Year:

Funding source:

Project:
1 JOB $460 $460
0"
PCODE ID10 CA only: At exterior door on wheelchair-accessible route, width of level and clear area at door swing
side does not extend 24" past the strike side edge.

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
2724
TBD CSAS 11B-26A(a)
Severity 1
Priority 5
General Fund
General Maintenance
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
8 lbs
PCODE ID03 Excessive force required to open metal gate at entrance.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2722
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
5 Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4653, Packet Page 4858 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 44"
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
2744
TBD
ADAAG Fig. A3(a)
Severity 3
Priority 3
General Fund
General Maintenance
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
15 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
2743
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Electrical
Project Year:

Funding source:

Project:
308.2.1 & 308.2.2
1 JOB $300 $300
50"
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.

Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2746
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2754
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
2739
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4654, Packet Page 4859 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
2740
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
7 Site Entry Stair at Spencer Street (Staff Only)
Cross Section
Project Year:

Funding source:

Project:
505.7
REF

2.5" wide
PCODE ED03REF Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2762
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at McClellan Ave.
• As-Built Description:
• Proposed Solution:
2765
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
PCODE ED05REF REF
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
2764
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02REF REF
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads when altering area.
• As-Built Description:
• Proposed Solution:
2760
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $2,040.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4655, Packet Page 4860 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Total Costs for Part: Exterior $2,040.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4656, Packet Page 4861 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Street Building Maintenance
1 Accessible Parking Space Serving Park and Center
Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
4359
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4358
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
2 POT from Acc. Parking Space to Slide Play Structure Entrance Gate Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
15 lbs
PCODE ID03 Excessive force required to open entrance gate at slide structure.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
4366
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07 1 JOB $250 $250
Door does not have accessible operating hardware.

Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
4368
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4657, Packet Page 4862 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
1 JOB $180 $180
5" gap
PCODE ID06B 10" min kick-plate/accessible operating hardware at gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
• As-Built:
4367
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
4 POT from Slide Play Structure to Swing Play Structure Entrance Gate Door Swing
Project Year:

Funding source:

Project:
404.2.4
REF
48" from face of door to dirt;

2.4%
PCODE ID23REF Front approach: At pull side, door does not have clear and level maneuvering space measuring door
width plus 18" x 60" (CA only: exterior door width
plus 24").

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
4378
TBD
ADAAG Fig. 25(a)
CSAS 11B-26A(a)
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
1 JOB $180 $180
11" gap
PCODE ID06B 10" min kick-plate/accessible operating hardware at gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
• As-Built:
4376
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign directing persons to an
accessible route to lower level basketball court
through the play structure area.
• As-Built Description:
• Proposed Solution:
4379
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 2 General Fund
General Maintenance
7 Men's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4658, Packet Page 4863 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
Accessories
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150

42.5" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4389
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4391
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
7 lbs
PCODE ID03 Excessive force required to open door.

Adjust regular door closer to accessible standards (5
lbs max).
• As-Built Description:
• Proposed Solution:
• As-Built:
4388
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4387
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4385
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4659, Packet Page 4864 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4386
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4392
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Urinal
Project Year:

Funding source:

Project:
605.3
1 JOB $150 $150
30" wide
PCODE WE04ANT 36" wide clearance in front of accessible urinal not provided when walls or partitions project more than
24" from the front edge of 30" x 48" clear space.

Reduce urinal partition depth to 24" max.
• As-Built Description:
• Proposed Solution:
• As-Built:
4398
TBD
ADAAG 4.18.3
CSAS 1115B.4.2.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
8 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
SD: 49" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
4412
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150

40.5" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4403
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4660, Packet Page 4865 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4405
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
4402
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05NT 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe need to be
re-insulated.

Re-insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4407
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4400
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4401
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4661, Packet Page 4866 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4404
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
9 POT from Public Restroom to Lower Barbecue / Picnic Area Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign.
• As-Built Description:
• Proposed Solution:
4418
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 2 General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
2 JOB $170 $340
0" - 4" extensions
PCODE ED05 Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4416
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
11 Stairs from Upper Patio to Lower Picnic / Barbecue Area Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06 4 JOB $170 $680
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
4424
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 32 LF $9 $288
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4422
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4662, Packet Page 4867 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
13 Stairs Entrance at Ramona Avenue
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06 4 JOB $170 $680
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
4429
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 28 LF $9 $252
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4428
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $5,225.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4663, Packet Page 4868 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue Building Maintenance
Total Costs for Part: Exterior $5,225.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4664, Packet Page 4869 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
7 Tennis Courts
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
REF
49" AFF
PCODE ID07REF Door hardware not centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor.

Relocate lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
2357
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:

PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
2356
TBD CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
General Maintenance
8 Stairs Connecting Tennis Court to Upper Play Area
Handrail
Project Year:

Funding source:

Project:
504.6
PCODE ED01 10 LF $95 $950
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2359
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.4
REF
32" AFF
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2361
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.7
10 LF $75 $750
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2358
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4665, Packet Page 4870 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
Project Year:

Funding source:

Project:
505.5
PCODE ED04NT 1 JOB $375 $375
Handrail adjacent to rough wall surface can pose
hazard.

Remount or modify handrail and adjacent wall to
minimize hazard.
• As-Built Description:
• Proposed Solution:
2360
TBD
ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
1" - 5" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2362
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Stairs
Project Year:

Funding source:

Project:
504.4
PCODE EC02 35 LF $9 $315
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2364
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
9 Stairs at South Side of Tennis Court
Handrail
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
4 JOB $170 $680
10" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2367
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Stairs
Project Year:

Funding source:

Project:
504.4
PCODE EC02 30 LF $9 $270
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2366
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
10 Stairs at NW Side of Park
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4666, Packet Page 4871 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
Handrail
Project Year:

Funding source:

Project:
504.6
PCODE ED01 32 LF $95 $3,040 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2370
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.4
REF
32" AFF
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2369
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
8" - 10" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2372
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible path to provide
direction to accessible entrances is missing or
noncompliant.

Provide signage sufficient to guide persons to
accessible path.
• As-Built Description:
• Proposed Solution:
2373
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 2 General Fund
General Maintenance
Stairs
Project Year:

Funding source:

Project:
504.4
PCODE EC02 96 LF $9 $864
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2371
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $7,654.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4667, Packet Page 4872 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 Building Maintenance
Total Costs for Part: Exterior $7,654.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4668, Packet Page 4873 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1006-0-1
Deer Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Deer Forest Road Building Maintenance
1 South Park Entrance at Deer Forest Drive
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Mule Dear Way.
• As-Built Description:
• Proposed Solution:
2839
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
2 North Park Entrance at Deer Forest Drive
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Mule Dear Way.
• As-Built Description:
• Proposed Solution:
2840
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $460.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4669, Packet Page 4874 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1006-0-1
Deer Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Deer Forest Road Building Maintenance
Total Costs for Part: Exterior $460.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4670, Packet Page 4875 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1007-0-1
Don Dahvee Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont Street & Iris Canyon Road Building Maintenance 1 Parking Area at Don Dahvee Lane
Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01A 1 JOB $300 $300
At parking lot with 1-25 spaces, the number of
accessible spaces is less than required by code; 1
space required
Provide required accessible parking space with sign
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
4010
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
4 Steep Section Under Mall Bridge
Walk
Project Year:

Funding source:

Project:
403.3
2 JOB $90 $180

7.3% - 10.7%
PCODE EF01NT Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Interim solution: Provide warning signs of steep
slope and directional sign to less steep sidewalk
when remodeling area.
• As-Built Description:
• Proposed Solution:
• As-Built:
4018
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
5 Trail and Bridge Leading to Mall Near Soledad
Accessible Route
Project Year:

Funding source:

Project:

PCODE EG08 15 LF $45 $675
(CA requirement only) Abrupt changes in level,
except between a walk or sidewalk and an adjacent
street or driveway, exceeding 4" in depth must be
identified by a 6" min. curb above the potential
drop off.

Provide a 6" curb as a warning curb for the blind or
a handrail centered +/- 3" above finished surface.
• As-Built Description:
• Proposed Solution:
4022
TBD CSAS 1133B.8.1
Severity 3
Priority 5
General Fund
General Maintenance
8 Steep Section Across from Clarion Hotel
Walk
Project Year:

Funding source:

Project:
403.3
REF

10.5% - 11%
PCODE EF01REF Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Recommended: Provide warning sign indicating
steep slope along trail or provide crosswalk to
sidewalk along other side of street.
• As-Built Description:
• Proposed Solution:
• As-Built:
4030
TBD
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
9 Trail Along Frisbee Golf Course
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4671, Packet Page 4876 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1007-0-1
Don Dahvee Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont Street & Iris Canyon Road Building Maintenance Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at non-accessible curb ramp at
intersection.
• As-Built Description:
• Proposed Solution:
4032
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $1,385.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4672, Packet Page 4877 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1007-0-1
Don Dahvee Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont Street & Iris Canyon Road Building Maintenance Total Costs for Part: Exterior $1,385.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4673, Packet Page 4878 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
1 Accessible Parking Serving North Upper Park and El Estero Boating Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07NT 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van sign.
• As-Built Description:
• Proposed Solution:
4707
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4705
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
2 Accessible Parking Serving North Upper Park and Visitor Center Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4712
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Accessible Parking at Camino El Estero Serving Southwest Portion of Park
4 Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
4721
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4720
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
5 Trail Along Lake Between Cemetery and Camino El Estero (Southwest March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4674, Packet Page 4879 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Cross Section
Project Year:

Funding source:

Project:
505.7
30 LF $75 $2,250
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4728
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4730
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF
28"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4729
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4731
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 90 LF $9 $810
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads (stairs to upper dog park).
• As-Built Description:
• Proposed Solution:
4727
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
6 Accessible Parking Serving Picnic Ground and Skate Park March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4675, Packet Page 4880 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07NT 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van sign.
• As-Built Description:
• Proposed Solution:
4735
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
4732
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 2 JOB $100 $200
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4733
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
7 POT from Acc. Parking to Viewing Balcony Above Lake
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01 24 LF $95 $2,280 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4750
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
9 POT from Acc. Parking to Group Picnic Area
Lavatory
Project Year:

Funding source:

Project:
606.4
PCODE WD06NT 1 JOB $600 $600
Accessible faucet (lever-operated, push-type or
electronically controlled) not provided at free
standing water faucet.

Provide accessible faucet at free standing water
faucet.
• As-Built Description:
• Proposed Solution:
4760
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
10 POT from Group Picnic Area to Upper Picnic Area at Pearl Street March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4676, Packet Page 4881 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.4
PCODE WD06NT 3 JOB $600 $1,800 Accessible faucet (lever-operated, push-type or electronically controlled) not provided at free
standing water faucet.

Provide accessible faucet at free standing water
faucet.
• As-Built Description:
• Proposed Solution:
4767
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stairs at Upper Picnic Area to Skate Park and Picnic Ground Parking Lot
11 Cross Section
Project Year:

Funding source:

Project:
505.7
54 LF $75 $4,050
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4769
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF
29"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4770
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" - 9" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4771
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 102 LF $9 $918
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4768
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
12 POT from Upper Picnic Area to Restroom Building (EEP Public March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4677, Packet Page 4882 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Cross Section
Project Year:

Funding source:

Project:
505.7
PCODE ED03 28 LF $75 $2,100 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
4774
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4777
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF
31"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4775
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4776
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 30 LF $9 $270
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4773
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
13 Men's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4678, Packet Page 4883 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 48" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4782
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 3
General Fund
General Maintenance
Project Year:

Funding source:

Project:
1 JOB $75 $75
SCD: 49" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4791
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
65" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4795
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4784
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4780
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4679, Packet Page 4884 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05CREF REF
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4794
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
REF
33"
PCODE WB05REF Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
4788
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
14 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SCD: 48" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4807
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 3
General Fund
General Maintenance
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
51" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4803
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
67" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4800
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4680, Packet Page 4885 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4801
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11ANT 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage. The existing sign is for
unisex restroom.

Provide ADAAG compliant women's restroom sign
mounted 5' high on center on nearest adjacent wall,
on latch side if a single door (located not to cause a
Braille reader to stand within the door swing).
• As-Built Description:
• Proposed Solution:
4798
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4797
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05CREF REF
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4810
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
REF
33"
PCODE WB05REF Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
4805
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4681, Packet Page 4886 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
15 Accessible Parking Serving Jr. Ball Park, Dance Studio and Snack Bar Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
4816
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4815
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
17 POT from Snack Bar Area to Bleacher
Cross Section
Project Year:

Funding source:

Project:
505.7
40 LF $75 $3,000
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4824
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
REF
8" extensions
PCODE ED05REF Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4825
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
18 Bleacher
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06NT 6 JOB $170 $1,020 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
4827
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4682, Packet Page 4887 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
19 POT from Bleacher to Northeast Dugout and Batting Cage Drinking Fountain
Project Year:

Funding source:

Project:
602.4
1 JOB $3,200 $3,200
37" AFG
PCODE IA03B Drinking fountain bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
4830
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
21 POT from Snack Bar Dinning Area to Northwest Dugout
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4841
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01NT 6 LF $95 $570
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4840
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06NT 1 JOB $170 $170
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
4839
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4683, Packet Page 4888 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 16 LF $9 $144
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4838
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
22 Accessible Parking Serving Dennis Playground
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4846
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
24 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
2 JOB $75 $150
EHD: 43.5" AFF
SD: 42.5" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4859
TBD
ADAAG Fig. A3(a)
Severity 4
Priority 3
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4861
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
606.4
1 JOB $50 $50
5 seconds
PCODE WD07 Lavatory: Self-closing faucet at accessible lavatory does not remain open for at least 10 seconds.

Adjust self-closing faucet at accessible lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4860
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4684, Packet Page 4889 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4857
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4868
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
25 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SCD: 41" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4883
TBD
ADAAG Fig. A3(a)
Severity 4
Priority 3
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4875
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4685, Packet Page 4890 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Project Year:

Funding source:

Project:
606.4
1 JOB $50 $50
5 seconds
PCODE WD07 Lavatory: Self-closing faucet at accessible lavatory does not remain open for at least 10 seconds.

Adjust self-closing faucet at accessible lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4873
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4871
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4876
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
26 POT from Restroom Building to Menace Playground Entrance Drinking Fountain
Project Year:

Funding source:

Project:
211.1
PCODE IA01A 1 JOB $2,000 $2,000 Where only one drinking fountain (Lion Head Drinking Fountain) is provided: Fountain is not
accessible to individuals who use wheelchairs, or to
those who have difficulty bending or stooping.

Provide additional fountain or hi-lo combination
fountain.
• As-Built Description:
• Proposed Solution:
4886
TBD
ADAAG 4.1.3(10)(a)
CSAS 1115B.4.6.1
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4686, Packet Page 4891 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06BREF REF
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4885
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
POT from Miracle Playground to Upper Joey's Play House and Picnic Area
29 Cross Section
Project Year:

Funding source:

Project:
505.7
32 LF $75 $2,400
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail (stairs at play structure to
lower sand box).
• As-Built Description:
• Proposed Solution:
• As-Built:
4902
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions (stairs at play structure to lower sand
box).
• As-Built Description:
• Proposed Solution:
4903
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing (stairs at play structure to lower sand
box).

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4904
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4687, Packet Page 4892 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 21 LF $9 $189
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads (stairs at Joey's house from picnic to play
structure).
• As-Built Description:
• Proposed Solution:
4900
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
504.4
PCODE EC02 33 LF $9 $297
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads (stairs at play structure to lower sand box).
• As-Built Description:
• Proposed Solution:
4901
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
30 POT from Upper Picnic Area to Lower Picnic Area
Cross Section
Project Year:

Funding source:

Project:
505.7
22 LF $75 $1,650
2" wide
PCODE ED03NT Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4913
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4914
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4915
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4688, Packet Page 4893 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 42 LF $9 $378
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4912
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
32 POT from Shrub Maze to Suspension Bridge
Cross Section
Project Year:

Funding source:

Project:
505.7
14 LF $75 $1,050
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail (stairs to steep sloped walk).
• As-Built Description:
• Proposed Solution:
• As-Built:
4932
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
60 LF $75 $4,500
24"
PCODE ED02 Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail (stairs to
lower sand box).
• As-Built Description:
• Proposed Solution:
• As-Built:
4929
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" -12" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4933
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 60 LF $9 $540
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads (stairs to lower sand box).
• As-Built Description:
• Proposed Solution:
4928
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4689, Packet Page 4894 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Project Year:

Funding source:

Project:
504.4
PCODE EC02NT 10 LF $9 $90
Contrasting color strip is fading at all stair nosings
(required in CA only).

Refinish contrasting color strips at all exterior stair treads when altering area (stairs to steep sloped
walk).
• As-Built Description:
• Proposed Solution:
4931
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
34 Parking Lot Serving City Dog Park (South of Pearl Street) Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01A 1 JOB $300 $300
At parking lot with 1-25 spaces, the number of
accessible spaces is less than required by code; 1
space required
Provide required accessible parking space with sign
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
4940
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
4941
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
35 Dog Park Entrance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4954
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.4
PCODE WD06NT 1 JOB $600 $600
Accessible faucet (lever-operated, push-type or
electronically controlled) not provided at free
standing water faucet.

Provide accessible faucet at free standing water
faucet.
• As-Built Description:
• Proposed Solution:
4943
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $42,166.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4690, Packet Page 4895 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1008-0-1
El Estero Park Complex Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 777 Pearl Street Building Maintenance
Total Costs for Part: Exterior $42,166.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4691, Packet Page 4896 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance 3 POT from Swing Structure to Press Box Building Gate Entrance Cross Section
Project Year:

Funding source:

Project:
505.7
17 LF $75 $1,275

5.5" wide
PCODE ED03 Wooden handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4277
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4271
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
17 LF $40 $680
31"
PCODE ED02B Wall mounted metal handrail gripping surface top not mounted between 34" and 38" above stair
nosings due to railing structure at eave.

Remove or relocate railing structure and remount
existing handrail at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4276
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
1 JOB $170 $170
0" extensions
PCODE ED06 Metal stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread
width sloped, plus 12" minimum horizontally
beyond the bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4278
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4692, Packet Page 4897 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 42 LF $9 $378
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4275
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
4 POT from Press Box Building Gate to Park Entrance at Encina Avenue Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07REF REF
Door does not have accessible operating hardware.

Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
4288
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06BREF REF
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4289
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
6 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SCD: 57" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4309
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 3
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4693, Packet Page 4898 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
70" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4308
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Entry Door
Project Year:

Funding source:

Project:

REF
48" to wall
PCODE WC03REF CA only: Restroom entry / exit door: 60" square clear space not provided at door swing side.

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
4291
TBD CSAS 1115B.3.1.1
Severity 2
Priority 5
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05NT 1 JOB $120 $120
Section of hot or sharp-surfaced water/drain pipe
not insulated or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4303
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4292
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4293
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4694, Packet Page 4899 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4298
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
7 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
2 JOB $75 $150
SD: 50" AFF
SCD: 57" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4327
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
68" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4320
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Electrical
Project Year:

Funding source:

Project:
308.2.1 & 308.2.2
1 JOB $300 $300
49" AFF
PCODE IC01 Electric switch or control mounted less than 36" or more than 48" above floor to center.

Relocate light switches or control to between 36"
and 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4328
TBD
ADAAG 4.2.5 & 6
CSAS 1117B.6.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4695, Packet Page 4900 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Entry Door
Project Year:

Funding source:

Project:

REF
48" to wall
PCODE WC03REF CA only: Restroom entry / exit door: 60" square clear space not provided at door swing side.

Change door swing.
• As-Built Description:
• Proposed Solution:
• As-Built:
4312
TBD CSAS 1115B.3.1.1
Severity 2
Priority 5
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4317
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4313
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4314
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4322
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
8 POT from Restroom Building to East Bleacher and Dugout March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4696, Packet Page 4901 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Drinking Fountain
Project Year:

Funding source:

Project:
602.2
1 JOB $3,200 $3,200
13" deep
PCODE IA02B Wall- and post-mounted cantilevered units:

Drinking fountain less than 17"-19" deep (front to
back).

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
4336
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
602.3
PCODE IA03REF REF
Fountain bubbler not easily activated by lever, push
bar, or other accessible control.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
4337
TBD
ADAAG 4.15.4
CSAS 1115B.4.6.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4338
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA07C 1 JOB $150 $150
Braille symbols on emergency phone: dots are not
1/10" on centers in each cell with 2/10" space
between cells.

CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
4330
TBD CSAS 1117B.5.6
Severity 3
Priority 4
General Fund
General Maintenance
9 POT from East Bleacher and Dugout to West Bleacher and Dugout Door Closer
Project Year:

Funding source:

Project:
404.2.9
1 JOB $25 $25
10 lbs
PCODE ID03NT Exterior door: excessive force required to open door.

Adjust regular door hinge to accessible standards (5
lbs max CA only).
• As-Built Description:
• Proposed Solution:
• As-Built:
4343
TBD
ADAAG 4.13.11
CSAS 1133B.2.5
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4697, Packet Page 4902 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 2 JOB $180 $360
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate at dugout and
batting cage.
• As-Built Description:
• Proposed Solution:
4342
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $8,023.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4698, Packet Page 4903 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues Building Maintenance Total Costs for Part: Exterior $8,023.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4699, Packet Page 4904 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1011-0-1
Fisherman Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Isola and San Vito Circle Building Maintenance 1 Park Entrance at San Vito Circle
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Trapani Circle.
• As-Built Description:
• Proposed Solution:
2812
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $230.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4700, Packet Page 4905 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1011-0-1
Fisherman Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Isola and San Vito Circle Building Maintenance Total Costs for Part: Exterior $230.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4701, Packet Page 4906 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Accessible Parking Serving Lower Park Area (Picnic, Tennis & Basketball)
1 Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4115
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20NT 1 JOB $170 $170
Sign to provide direction to upper park accessible
parking at Devisadero is missing.

Provide directional sign.
• As-Built Description:
• Proposed Solution:
4119
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 3
Priority 1 General Fund
General Maintenance
2 POT from Accessible Parking Space to Picnic Area
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07REF REF
Door does not have accessible operating hardware.

Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
4121
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 2 JOB $180 $360
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4120
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
5 Men's Restroom Serving Lower Park
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4702, Packet Page 4907 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Accessories
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
47" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4139
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4133
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
4127
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4128
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4129
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4703, Packet Page 4908 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500
32" clear opening width
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
4132
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4134
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Wheelchair Clearance
Project Year:

Funding source:

Project:
1 JOB $750 $750
42"
PCODE WC02ANT Clear passage width (except doorways) from rest room entry to accessible water closet compartment
less than 36" (CA only: 44" wide).

Modify facility passage to be min. 44" wide.

Demolish portion of existing partition wall and
refinish to match existing
• As-Built Description:
• Proposed Solution:
• As-Built:
4126
TBD
ADAAG 4.3.3
CSAS 1115B.3.2.4
Severity 2
Priority 3 General Fund
General Maintenance
6 Women's Restroom Serving Lower Park
Accessories
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
43" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4155
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4149
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4704, Packet Page 4909 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Door Stopper
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06A 1 JOB $25 $25
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Remove door stopper when altering area. Provide
rubber wedge.
• As-Built Description:
• Proposed Solution:
4143
TBD
CSAS 1133B.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4144
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4145
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500
32" clear opening width
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
4148
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4150
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4705, Packet Page 4910 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Wheelchair Clearance
Project Year:

Funding source:

Project:
1 JOB $750 $750
39"
PCODE WC02ANT Clear passage width (except doorways) from rest room entry to accessible water closet compartment
less than 36" (CA only: 44" wide).

Modify facility passage to be min. 44" wide.

Demolish portion of existing partition wall and
refinish to match existing
• As-Built Description:
• Proposed Solution:
• As-Built:
4142
TBD
ADAAG 4.3.3
CSAS 1115B.3.2.4
Severity 2
Priority 3 General Fund
General Maintenance
Accessible Parking at Divisadero Serving Upper Park Area & Hilltop Center
7 Identification
Project Year:

Funding source:

Project:
502.6
REF
45" o.c. AFG
PCODE EA04BREF Sign for accessible parking space is missing or noncompliant.

Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
• As-Built:
4160
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07REF REF
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
4164
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Aisle
Project Year:

Funding source:

Project:
502.3.4
PCODE EA02CNT 1 JOB $3,000 $3,000 Accessible parking aisle is not located on the passenger side (required in CA only).

Redesign parking layout to provide van accessible
parking with access aisle on the passenger side and
provide van sign and curb cut per requirements.
• As-Built Description:
• Proposed Solution:
4161
TBD
CSAS 1129B.3.1
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
4159
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4706, Packet Page 4911 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4158
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20NT 1 JOB $170 $170
Sign to provide direction to lower park on-site
accessible parking is missing.

Provide directional sign.
• As-Built Description:
• Proposed Solution:
4165
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 3
Priority 1 General Fund
General Maintenance
9 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
41" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4182
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
63" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4173
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4183
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4707, Packet Page 4912 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4170
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500
33"
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
4171
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4174
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
11 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 42.5" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4198
TBD
ADAAG Fig. A3(a)
Severity 4
Priority 3
General Fund
General Maintenance
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
41" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
4197
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4708, Packet Page 4913 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
58" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4190
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4199
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4187
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500

33.5" o.c. AFF
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
4189
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4191
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
POT from Men's Restroom to Drinking Fountain Adjacent to Jessie Street Exit Stairs
12 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4709, Packet Page 4914 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Cross Section
Project Year:

Funding source:

Project:
505.7
33 LF $75 $2,475
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4207
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF
32"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4208
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06REF REF
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
4209
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 56 LF $9 $504
Contrasting color strip not provided at all stair
nosings (required in CA only) at stairs leading to
Jessie street adjacent to flag pole.

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4206
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
13 POT from Drinking Fountain to Play Area 1
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07REF REF
Door does not have accessible operating hardware.

Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
4212
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4710, Packet Page 4915 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4211
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
16 Parking at Jessie Street Serving Upper Park Area
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20NT 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.

Provide sign directing people to accessible parking
space and entrance at upper and lower park.
• As-Built Description:
• Proposed Solution:
4227
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
Total Costs for Floor: On-Site $17,159.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4711, Packet Page 4916 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1012-0-1
Hilltop Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 871 Jessie Street Building Maintenance
Total Costs for Part: Exterior $17,159.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4712, Packet Page 4917 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1013-0-1
Hoffman Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
1 Accessible Parking Serving Hoffman Park (1 Space)
Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01ANT 1 JOB $300 $300
At parking lot with 1-25 spaces, the number of
accessible spaces is less than required by code; 1
space required (Note: 1 space provided on site, but
it is not accessible due to emergency storage unit)
Relocate and provide required accessible parking
space with sign including a minimum of one van
space at brick paver side of lot.
• As-Built Description:
• Proposed Solution:
2767
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07REF REF
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
2772
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
2766
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
2771
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
5 South Parking Lot Stair at Archer Street
Cross Section
Project Year:

Funding source:

Project:
505.7
24 LF $75 $1,800
6" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2789
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4713, Packet Page 4918 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1013-0-1
Hoffman Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF
43"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2788
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at lower parking lot.
• As-Built Description:
• Proposed Solution:
2811
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
PCODE ED05REF REF
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
2790
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 45 LF $9 $405
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2786
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
6 West Stair from Upper Parking Lot to Lower Play Structure Area Height
Project Year:

Funding source:

Project:
505.4
36 LF $75 $2,700
33"
PCODE ED02 Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2794
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4714, Packet Page 4919 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1013-0-1
Hoffman Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
8" - 10" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2795
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 54 LF $9 $486
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2792
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
East Sloped Brick Pathway from Upper Parking Lot to Lower Play Structure Area
7 Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2800
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02REF REF
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads when altering area.
• As-Built Description:
• Proposed Solution:
2799
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Central Stair from Play Structure Area to Lower Lawn Area / Park Entrance at Spencer St.
8 Cross Section
Project Year:

Funding source:

Project:
505.7
42 LF $75 $3,150
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2804
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4715, Packet Page 4920 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1013-0-1
Hoffman Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Handrail
Project Year:

Funding source:

Project:

PCODE ED13REF REF
Handrails not returned to wall or newel post.

Add handrail return.
• As-Built Description:
• Proposed Solution:
2805
TBD
ADAAG 4.9.4(6)
CSAS 1133B.4.2.3
Severity 3
Priority 2 General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at upper parking lot.
• As-Built Description:
• Proposed Solution:
2810
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 112 LF $9 $1,008 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2802
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $10,734.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4716, Packet Page 4921 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1013-0-1
Hoffman Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. Building Maintenance
Total Costs for Part: Exterior $10,734.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4717, Packet Page 4922 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance 1 Accessible Parking Serving Jack's Park
Identification
Project Year:

Funding source:

Project:
502.6
PCODE EA04B 2 JOB $315 $630
Sign for accessible parking space is missing or noncompliant.

Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
3936
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01CNT 1 JOB $300 $300
At parking lot with 51-75 spaces, the number of
accessible spaces is less than required by code; 3
spaces required.

Provide required accessible parking spaces with
signs including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
3938
TBD
ADAAG 4.1.2(5)*
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 3 JOB $100 $300
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
3937
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
3 POT from Play Structure to Northeast Bleacher
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06 2 JOB $170 $340
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
3953
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06NT 1 JOB $170 $170
Stair handrail (bleacher adjacent to dugout) does
not extend horizontally 12" minimum beyond top
nosing, and one tread width sloped, plus 12"
minimum horizontally beyond the bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
3955
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4718, Packet Page 4923 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 120 LF $9 $1,080 Contrasting color strips at all stair nosings are fading (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
3952
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
504.4
PCODE EC02 40 LF $9 $360
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads (bleacher adjacent to dugout).
• As-Built Description:
• Proposed Solution:
3954
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
4 POT from Northeast Bleacher to Dugout and Batting Cage Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
3958
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
5 Northwest Bleacher
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06 2 JOB $170 $340
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
3961
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
6 POT from Northwest Bleacher to Dugout
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4719, Packet Page 4924 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
3962
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
7 POT from Northwest Bleacher to Restroom Building
Drinking Fountain
Project Year:

Funding source:

Project:
602.4
1 JOB $3,200 $3,200
38" AFG
PCODE IA03B Drinking fountain bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
3967
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
8 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 47" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
3974
TBD
ADAAG Fig. A3(a)
Severity 3
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
69" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3978
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4720, Packet Page 4925 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05REF REF
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
3975
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3971
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3970
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware at inside of stall door (U-pulls on both
sides, flip-over or sliding lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
3977
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
9 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4721, Packet Page 4926 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SDP: 44" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
3995
TBD
ADAAG Fig. A3(a)
Severity 3
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
60" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3996
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05REF REF
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
3993
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3990
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3991
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4722, Packet Page 4927 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware at inside of stall door (U-pulls on both
sides, flip-over or sliding lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
3997
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $7,890.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4723, Packet Page 4928 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1014-0-1
Jacks Ball Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Franklin & Figueroa Streets Building Maintenance Total Costs for Part: Exterior $7,890.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4724, Packet Page 4929 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1016-0-1
Laguna Grande Regional Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte and Virgin Avenue Building Maintenance 1 Parking Lot Serving Laguna Grande Park at Virgin Street Identification
Project Year:

Funding source:

Project:
502.6
PCODE EA04BREF REF
Sign for accessible parking space is missing or noncompliant.

Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
4633
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
4632
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4635
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
5 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 44" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4668
TBD
ADAAG Fig. A3(a)
Severity 3
Priority 3
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4669
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4725, Packet Page 4930 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1016-0-1
Laguna Grande Regional Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte and Virgin Avenue Building Maintenance Project Year:

Funding source:

Project:
606.4
1 JOB $50 $50
5 seconds
PCODE WD07 Lavatory: Self-closing faucet at accessible lavatory does not remain open for at least 10 seconds.

Adjust self-closing faucet at accessible lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4675
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4665
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
6 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 44" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4681
TBD
ADAAG Fig. A3(a)
Severity 3
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
60" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4686
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
4683
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4726, Packet Page 4931 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1016-0-1
Laguna Grande Regional Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte and Virgin Avenue Building Maintenance Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4676
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4682
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $1,220.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4727, Packet Page 4932 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1016-0-1
Laguna Grande Regional Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte and Virgin Avenue Building Maintenance Total Costs for Part: Exterior $1,220.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4728, Packet Page 4933 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street Building Maintenance
5 South Park Entrance Stairs
Handrail
Project Year:

Funding source:

Project:
505.4
REF
33" AFF
PCODE ED02BREF Wall mounted handrail gripping surface top not mounted between 34" and 38" above ramp surface.

Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2274
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.7
14 LF $75 $1,050
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2272
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
4" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2273
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible west entrance.
• As-Built Description:
• Proposed Solution:
2271
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1 General Fund
General Maintenance
Stairs
Project Year:

Funding source:

Project:
504.4
PCODE EC02 33 LF $9 $297
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2275
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
8 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4729, Packet Page 4934 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street Building Maintenance
Accessories
Project Year:

Funding source:

Project:
1 JOB $100 $100
SD: 41"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
2291
TBD CSAS 1115B.8.3
Severity 4
Priority 5
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2292
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.

CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
2287
TBD CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
2288
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
2294
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4730, Packet Page 4935 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street Building Maintenance
9 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $100 $100
SD: 43"
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
2302
TBD CSAS 1115B.8.3
Severity 4
Priority 5
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2301
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA07C 1 JOB $150 $150
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.

CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
• As-Built Description:
• Proposed Solution:
2298
TBD CSAS 1117B.5.6
Severity 3
Priority 3
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
2299
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4731, Packet Page 4936 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street Building Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
2305
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $2,697.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4732, Packet Page 4937 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street Building Maintenance
Total Costs for Part: Exterior $2,697.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4733, Packet Page 4938 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1021-0-1
Montecito Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Montecito and Dela Vina Avenues Building Maintenance 5 POT from Intersecting Path to Restroom Building
Drinking Fountain
Project Year:

Funding source:

Project:

PCODE IA01BNT 1 JOB $3,200 $3,200 Where more than one drinking fountain is provided per floor, less than 50% comply with ADAAG

4.15. Front approach is not available at existing
drinking fountain due to its orientation.

Provide accessible fountain or relocate existing to
compliance.
• As-Built Description:
• Proposed Solution:
2911
TBD
ADAAG 4.1.3.(10)(b)
CSAS 1115B.4.6.1
Severity 2
Priority 3 General Fund
General Maintenance
Project Year:

Funding source:

Project:
602.6
1 JOB $3,200 $3,200
9"
PCODE IA03A Oval and round drinking fountains: bubbler outlet more than 3" from front edge of fountain (CA only:
all drinking fountain bubbler out lets more than 6"
from front edge).

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
2913
TBD
ADAAG 4.15.3
CSAS 1115B.4.6.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
6 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SDP: 44" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
2919
TBD
ADAAG Fig. A3(a)
Severity 3
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
60" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2925
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4734, Packet Page 4939 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1021-0-1
Montecito Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Montecito and Dela Vina Avenues Building Maintenance Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2918
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
2915
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
216.8
PCODE SA11 1 JOB $90 $90
Entrance to wheelchair accessible toilet or bathing
facility not identified with the International Symbol
of Accessibility when not all are accessible.

Provide sanitary facility sign that shows the
international symbol.
• As-Built Description:
• Proposed Solution:
2916
TBD
ADAAG 4.1.2(7)(d)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500
32" clear opening width
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
2922
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (no U-pull at inside of stall).

Provide U-pull at inside of stall door.
• As-Built Description:
• Proposed Solution:
2926
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
7 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4735, Packet Page 4940 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1021-0-1
Montecito Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Montecito and Dela Vina Avenues Building Maintenance Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SD: 42" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
2932
TBD
ADAAG Fig. A3(a)
Severity 4
Priority 3
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
61" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2934
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2933
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
2928
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
216.8
PCODE SA11 1 JOB $90 $90
Entrance to wheelchair accessible toilet or bathing
facility not identified with the International Symbol
of Accessibility when not all are accessible.

Provide sanitary facility sign that shows the
international symbol.
• As-Built Description:
• Proposed Solution:
2929
TBD
ADAAG 4.1.2(7)(d)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4736, Packet Page 4941 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1021-0-1
Montecito Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Montecito and Dela Vina Avenues Building Maintenance Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (no U-pull at inside of stall).

Provide U-pull at inside of stall door.
• As-Built Description:
• Proposed Solution:
2931
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $8,950.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4737, Packet Page 4942 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1021-0-1
Montecito Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Montecito and Dela Vina Avenues Building Maintenance Total Costs for Part: Exterior $8,950.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4738, Packet Page 4943 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1022-0-1
Monterey Bay Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte Avenue Building Maintenance
1 Accessible Parking Spaces Serving Monterey Bay Park (2 Spaces) Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
2855
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 2 JOB $100 $200
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
2857
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
8 Unisex Restroom Inside of Monterey Bay Kayaks Building Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
PTD: 58" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
2897
TBD
ADAAG Fig. A3(a)
Severity 2
Priority 3
General Fund
General Maintenance
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
48" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
2887
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2888
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4739, Packet Page 4944 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1022-0-1
Monterey Bay Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte Avenue Building Maintenance
Signage
Project Year:

Funding source:

Project:
703.4.1
PCODE SA07NT 1 JOB $90 $90
Compliant sign identifying permanent room or
space not mounted 60" high to center on nearest
adjacent wall, on latch side if a single door (located
not to cause a Braille reader to stand within the
door swing).

Provide compliant signage including tactile
characters and Grade II Braille on latch side of door
located 60" on center from floor.
• As-Built Description:
• Proposed Solution:
2884
TBD
ADAAG 4.30.6
CSAS 1117B.5.7
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
216.8
PCODE SA11REF REF
Entrance to wheelchair accessible toilet or bathing
facility not identified with the International Symbol
of Accessibility when not all are accessible.

Provide sanitary facility sign that shows the
international symbol.
• As-Built Description:
• Proposed Solution:
2885
TBD
ADAAG 4.1.2(7)(d)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
216.2
PCODE SA13A 1 JOB $90 $90
Sign identifying permanent room does not include
sans serif, upper case, raised 1/32" min. tactile
characters and Grade 2 Braille.

Provide compliant room identifying signage,
including raised letters and Grade 2 Braille.
• As-Built Description:
• Proposed Solution:
2886
TBD
ADAAG 4.1.3(16)(a)
CSAS 1117B.5
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $1,050.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4740, Packet Page 4945 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1022-0-1
Monterey Bay Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Del Monte Avenue Building Maintenance
Total Costs for Part: Exterior $1,050.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4741, Packet Page 4946 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1023-0-1
Oak Newton Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oak and Newton Streets Building Maintenance
6 Men's Restroom
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2966
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
2963
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
216.8
PCODE SA11 1 JOB $90 $90
Entrance to wheelchair accessible toilet or bathing
facility not identified with the International Symbol
of Accessibility when not all are accessible.

Provide sanitary facility sign that shows the
international symbol.
• As-Built Description:
• Proposed Solution:
2964
TBD
ADAAG 4.1.2(7)(d)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
7 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $75 $75
SDP: 41" AFF
PCODE WG01 Individuals using wheelchairs, crutches, or walkers cannot reach paper towel and/or soap dispensers
from designated accessible sink(s) or lavatory(s).

Relocate paper towel and/or soap dispensers to be
within immediate reach range of a person standing
or sitting at an accessible sink or lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
2985
TBD
ADAAG Fig. A3(a)
Severity 4
Priority 3
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
2980
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4742, Packet Page 4947 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1023-0-1
Oak Newton Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oak and Newton Streets Building Maintenance
Signage
Project Year:

Funding source:

Project:
703.2
PCODE SA07A 1 JOB $90 $90
Sign designating a permanent room or space does
not include Grade 2 Braille.

Provide new compliant signage including California
Grade 2 Braille (1/10" on center dots with 2/10"
space between cells).
• As-Built Description:
• Proposed Solution:
2977
TBD
ADAAG 4.30.4
CSAS 1117B.5.6
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
216.8
PCODE SA11 1 JOB $90 $90
Entrance to wheelchair accessible toilet or bathing
facility not identified with the International Symbol
of Accessibility when not all are accessible.

Provide sanitary facility sign that shows the
international symbol.
• As-Built Description:
• Proposed Solution:
2978
TBD
ADAAG 4.1.2(7)(d)
CSAS 1117B.5.8.1.2
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
8 POT from Upper Play Structure Area to Lower Play Structure Area Cross Section
Project Year:

Funding source:

Project:
505.7
PCODE ED03 72 LF $75 $5,400 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
2994
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2996
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF

32.5"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2995
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4743, Packet Page 4948 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1023-0-1
Oak Newton Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oak and Newton Streets Building Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 160 LF $9 $1,440 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2993
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
10 POT from Lower Play Structure to Bridge
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
3005
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02REF REF
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads when altering area.
• As-Built Description:
• Proposed Solution:
3004
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
11 POT from Bridge to Stairway (Staff Only) at Pvt Bolio Road Cross Section
Project Year:

Funding source:

Project:
505.7
40 LF $75 $3,000
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
3008
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01 54 LF $95 $5,130 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
3013
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4744, Packet Page 4949 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1023-0-1
Oak Newton Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oak and Newton Streets Building Maintenance
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Newton Street entrance.
• As-Built Description:
• Proposed Solution:
3011
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
PCODE ED05REF REF
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
3009
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 64 LF $9 $576
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
3010
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
12 East Park Entrance at Oak Street
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Newton street.
• As-Built Description:
• Proposed Solution:
3014
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
13 West Park Entrance at Oak Street
Signage
Project Year:

Funding source:

Project:
216.6
PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances at Newton street.
• As-Built Description:
• Proposed Solution:
3015
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $16,911.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4745, Packet Page 4950 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1023-0-1
Oak Newton Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Oak and Newton Streets Building Maintenance
Total Costs for Part: Exterior $16,911.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4746, Packet Page 4951 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1027-0-1
Ryan Ranch Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Ryan Ranch & Park Roads Building Maintenance
1 Parking Lot Serving Ryan Ranch Park
Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01C 1 JOB $1,000 $1,000 At parking lot with 51-75 spaces, the number of accessible spaces is less than required by code; 3
spaces required.

Provide required accessible parking spaces close to
park entrance with signs & detectable warning
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
4540
TBD ADAAG 4.1.2(5)*
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
4541
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04GREF REF
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
4544
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
3 Stairs to 19 Hole (North of Parking Lot)
Cross Section
Project Year:

Funding source:

Project:
505.7
REF

5.5" wide
PCODE ED03REF Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4554
TBD ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 4
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01NT 28 LF $95 $2,660 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4553
TBD ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4747, Packet Page 4952 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1027-0-1
Ryan Ranch Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Ryan Ranch & Park Roads Building Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" -12" extensions
PCODE ED06AREF Floor mounted stair handrail does not extend horizontally 12" minimum beyond top nosing, and
one tread width sloped, plus 12" minimum
horizontally beyond the bottom nosing.

Extend stair handrail at top and bottom (cost for
both extensions).
• As-Built Description:
• Proposed Solution:
• As-Built:
4555
TBD ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 28 LF $9 $252
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4549
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
4 Stairs to Private Company Parking Lot
Clearance
Project Year:

Funding source:

Project:
505.5
PCODE ED04REF REF
Handrail: Clearance to wood board support is not 1
-1/2".

Remount existing handrail.
• As-Built Description:
• Proposed Solution:
4563
TBD ADAAG 4.9.4(3)
CSAS 1133B.4.2.5 & B.5.5
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Cross Section
Project Year:

Funding source:

Project:
505.7
REF
2" wide
PCODE ED03REF Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4561
TBD ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 4
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01NT 30 LF $95 $2,850 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4560
TBD ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4748, Packet Page 4953 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1027-0-1
Ryan Ranch Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Ryan Ranch & Park Roads Building Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign.
• As-Built Description:
• Proposed Solution:
4564
TBD ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 4 General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" -12" extensions
PCODE ED06AREF Floor mounted stair handrail does not extend horizontally 12" minimum beyond top nosing, and
one tread width sloped, plus 12" minimum
horizontally beyond the bottom nosing.

Extend stair handrail at top and bottom (cost for
both extensions).
• As-Built Description:
• Proposed Solution:
• As-Built:
4562
TBD ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 4
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 40 LF $9 $360
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4556
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $7,617.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4749, Packet Page 4954 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1027-0-1
Ryan Ranch Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Ryan Ranch & Park Roads Building Maintenance
Total Costs for Part: Exterior $7,617.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4750, Packet Page 4955 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance 2 POT from Acc Parking to Central Stairway
Curb or Barrier
Project Year:

Funding source:

Project:
405.9.2
PCODE EB14REF REF
Ramp: No curb (2" minimum height) or wheel
guide (centered approx. 3" above surface of ramp)
at sides of ramp.

Provide 2" minimum curb or wheel guide.
• As-Built Description:
• Proposed Solution:
5546
TBD
ADAAG 4.8.7
CSAS 1133B.5.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 2 JOB $170 $340
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign.
• As-Built Description:
• Proposed Solution:
5548
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
3 POT from Central Stairway to Beach Ramp Access
Drinking Fountain
Project Year:

Funding source:

Project:
602.4
1 JOB $1,200 $1,200
39"
PCODE IA03C Drinking fountain bubbler more than 36" above floor.

Remount fountain at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5553
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
4 Ramp Access to Beach
Top and Bottom Extension at
Ramps
Project Year:

Funding source:

Project:
505.10.1
4 JOB $170 $680
0" - 10" extensions
PCODE ED05 Ramp handrail does not extend horizontally 12" past top and / or bottom of ramp.

Provide ramp handrail extension (cost for each
extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5554
TBD
ADAAG 4.8.5(2)
1133B.4.2.2 &
1133B.5.5.1
CSAS
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
5 Central Stair Access to Beach
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4751, Packet Page 4956 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
PCODE ED06 2 JOB $170 $340
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
5559
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 264 LF $9 $2,376 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
5558
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
7 Multiple Stair Cases at East End of Park (Near Breakwater Lot) Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
4 JOB $170 $680
10" extensions
PCODE ED06 Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
5563
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02NT 1 JOB $2,000 $2,000 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads when altering area.
• As-Built Description:
• Proposed Solution:
5562
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
8 POT from Beach Access Ramp to Restroom
Drinking Fountain
Project Year:

Funding source:

Project:
602.4
1 JOB $3,200 $3,200

37.5" AFG
PCODE IA03B Drinking fountain bubbler more than 36" above floor.

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
5567
TBD
ADAAG 4.15.2
CSAS 1115B.4.6.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4752, Packet Page 4957 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance 9 Men's Restroom
Accessible Compartment
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05DNT 1 JOB $500 $500
The location of the stall door is not in front of the
clear space (next to the water closet), with a
maximum stile width of 4 ".

Remodel compartment.
• As-Built Description:
• Proposed Solution:
5579
TBD
ADAAG 4.17.3 & Fig. 30(a)
CSAS 1115B.3.1.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Accessories
Project Year:

Funding source:

Project:
3 JOB $100 $300
SD: 45" AFF
SCD: 46" AFF
EHD: 45" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
5574
TBD CSAS 1115B.8.3
Severity 3
Priority 5
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
55" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5584
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
5572
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4753, Packet Page 4958 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5569
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5570
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5578
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
10 Women's Restroom
Accessible Compartment
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05DNT 1 JOB $500 $500
The location of the stall door is not in front of the
clear space (next to the water closet), with a
maximum stile width of 4 ".

Remodel compartment.
• As-Built Description:
• Proposed Solution:
5599
TBD
ADAAG 4.17.3 & Fig. 30(a)
CSAS 1115B.3.1.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4754, Packet Page 4959 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
55" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
5595
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
5589
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
5586
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
5587
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
5593
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4755, Packet Page 4960 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance 11 POT from Site Entry Near Hotel at Cannery Row to Memorial Fountain Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 2 JOB $170 $340
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign.
• As-Built Description:
• Proposed Solution:
5605
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
Total Costs for Floor: On-Site $13,356.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4756, Packet Page 4961 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1028-0-1
San Carlos Beach Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Cannery Row at Reeside Avenue Building Maintenance Total Costs for Part: Exterior $13,356.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4757, Packet Page 4962 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1029-0-1
Scholze Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Lighthouse Ave and Dickman Ave Building Maintenance 1 POT from Site Entry on Lighthouse Ave. to Park Corner at Drake Signage
Project Year:

Funding source:

Project:

PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
2310
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 1 General Fund
General Maintenance
2 Stair at Park Corner at Drake Ave.

Handrail
Project Year:

Funding source:

Project:
504.6
PCODE ED01 28 LF $95 $2,660 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
2322
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" - 7" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2325
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA01 1 JOB $230 $230
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to south
accessible entrances.
• As-Built Description:
• Proposed Solution:
2321
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 2 General Fund
General Maintenance
Stairs
Project Year:

Funding source:

Project:
504.4
PCODE EC02 54 LF $9 $486
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2323
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
4 Corner Entrance at Dickman and Lighthouse Ave.

March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4758, Packet Page 4963 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1029-0-1
Scholze Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Lighthouse Ave and Dickman Ave Building Maintenance Handrail
Project Year:

Funding source:

Project:
505.4
REF
40" AFF
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2332
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.7
24 LF $75 $1,800

1.75" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
2330
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" - 9" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
2331
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:

PCODE SA01 2 JOB $230 $460
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing
or noncompliant.

Provide signage sufficient to guide persons to
accessible entrances.
• As-Built Description:
• Proposed Solution:
2329
TBD
ADAAG 4.1.2(7)(c)
CSAS 1117B.5.8.1.2
Severity 3
Priority 2 General Fund
General Maintenance
Stairs
Project Year:

Funding source:

Project:
504.4
PCODE EC02 40 LF $9 $360
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
2334
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $6,226.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4759, Packet Page 4964 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1029-0-1
Scholze Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Lighthouse Ave and Dickman Ave Building Maintenance Total Costs for Part: Exterior $6,226.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4760, Packet Page 4965 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1030-0-1
Fisherman's Shoreline Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Between Fisherman's Wharf & Coast Guard Pier Building Maintenance 3 POT from Drinking Fountain to Viewing Area No. 1
Cross Section
Project Year:

Funding source:

Project:
505.7
28 LF $75 $2,100
3" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4592
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF

33.5"
PCODE ED02AREF Wall mounted handrail gripping surface top not mounted between 34" and 38" above ramp surface.

Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4594
TBD
ADAAG 4.8.5(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4593
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 72 LF $9 $648
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4591
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
4 POT from Viewing Area No. 1 to Viewing Area No. 2
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01 12 LF $95 $1,140 Handrail not provided at stairs or ramp, required on both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4596
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4761, Packet Page 4966 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1030-0-1
Fisherman's Shoreline Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Between Fisherman's Wharf & Coast Guard Pier Building Maintenance Ramp
Project Year:

Funding source:

Project:
403.1
PCODE EB01C 95 SF $45 $4,275 Sloped walk needed to provide disabled access at steps or change of level along path of travel.

Provide new concrete sloped walk without
handrails [slope less than 1:20 (5.0%)].
• As-Built Description:
• Proposed Solution:
4597
TBD
ADAAG 4.1.1 & 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 48 LF $9 $432
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4595
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
5 POT from Viewing Area No. 2 to Viewing Area No. 3
Cross Section
Project Year:

Funding source:

Project:
505.7
24 LF $75 $1,800
3" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4601
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 1
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF

33.5"
PCODE ED02AREF Wall mounted handrail gripping surface top not mounted between 34" and 38" above ramp surface.

Remount existing handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
4603
TBD
ADAAG 4.8.5(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4602
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 2
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4762, Packet Page 4967 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1030-0-1
Fisherman's Shoreline Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Between Fisherman's Wharf & Coast Guard Pier Building Maintenance Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 56 LF $9 $504
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4600
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
7 POT from Viewing Area No. 4 to Picnic Area
Ramp
Project Year:

Funding source:

Project:
403.1
PCODE EB01CREF REF
Sloped walk needed to provide disabled access at
steps or change of level along path of travel due to
existing curb.

Provide new concrete sloped walk without
handrails [slope less than 1:20 (5.0%)].
• As-Built Description:
• Proposed Solution:
4611
TBD
ADAAG 4.1.1 & 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
POT from Picnic Area to East Park Entrance at Old Fisherman's Wharf Plaza
8 Cross Section
Project Year:

Funding source:

Project:
505.7
40 LF $75 $3,000
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail at stairs to upper Heritage
Harbor.
• As-Built Description:
• Proposed Solution:
• As-Built:
4616
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.7
88 LF $75 $6,600
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail at stairs to beach access.
• As-Built Description:
• Proposed Solution:
• As-Built:
4628
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Handrails
Project Year:

Funding source:

Project:
504.6
PCODE ED01REF REF
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).

Provide new handrail for each side including
extensions.
• As-Built Description:
• Proposed Solution:
4624
TBD
ADAAG 4.8.5 & 4.9.4
CSAS 1133B.4.1.1 & .5.5
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4763, Packet Page 4968 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1030-0-1
Fisherman's Shoreline Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Between Fisherman's Wharf & Coast Guard Pier Building Maintenance Height
Project Year:

Funding source:

Project:
505.4
REF
33"
PCODE ED02AREF Wall mounted handrail gripping surface top not mounted between 34" and 38" above ramp surface.

Remount existing handrail at Stairs to upper
Heritage Harbor.
• As-Built Description:
• Proposed Solution:
• As-Built:
4618
TBD
ADAAG 4.8.5(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign at sloped walkway to upper
Fisherman's Wharf lot.
• As-Built Description:
• Proposed Solution:
4626
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing at stairs to upper Heritage Harbor.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
4617
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
0" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece) at stairs to beach access.
• As-Built Description:
• Proposed Solution:
• As-Built:
4629
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 240 LF $9 $2,160 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads (stairs to upper Heritage Harbor).
• As-Built Description:
• Proposed Solution:
4615
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4764, Packet Page 4969 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1030-0-1
Fisherman's Shoreline Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Between Fisherman's Wharf & Coast Guard Pier Building Maintenance Project Year:

Funding source:

Project:
504.4
PCODE EC02 150 LF $9 $1,350 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads at stairs to beach access.
• As-Built Description:
• Proposed Solution:
4627
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $24,179.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4765, Packet Page 4970 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1030-0-1
Fisherman's Shoreline Park Part: Exterior Floor: On-Site City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Between Fisherman's Wharf & Coast Guard Pier Building Maintenance Total Costs for Part: Exterior $24,179.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4766, Packet Page 4971 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1032-0-1
Spray Avenue Tot Lot Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Spray Avenue Building Maintenance
1 Park Entrance at Spray Avenue
Door Hardware
Project Year:

Funding source:

Project:
404.2.7
PCODE ID07REF REF
Door does not have accessible operating hardware.

Provide lever handle or other accessible hardware.
• As-Built Description:
• Proposed Solution:
4236
TBD
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
4235
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4767, Packet Page 4972 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1032-0-1
Spray Avenue Tot Lot Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Spray Avenue Building Maintenance
Total Costs for Part: Exterior $180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4768, Packet Page 4973 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance 1 Accessible Parking Serving Lower Restrooms & Basketball Court Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07NT 1 JOB $350 $350
Access aisle is provided on driver side (one in every
8 accessible spaces, but not less than one, 8' wide
access aisle to the right of the parking stall, 98"
height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
3701
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
3702
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
2 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
1 JOB $100 $100
SD: 42" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3707
TBD CSAS 1115B.8.3
Severity 4
Priority 5
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
57" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3712
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4769, Packet Page 4974 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3705
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware on outside of stall door.

Provide U-pull on outside of stall door
• As-Built Description:
• Proposed Solution:
3708
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
3 Women's Restroom
Accessories
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
SCD: 49" AFF
SD: 41" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3715
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
57" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3721
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4770, Packet Page 4975 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Signage
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3713
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware on outside of stall door.

Provide U-pull on outside of stall door.
• As-Built Description:
• Proposed Solution:
3716
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
6 Accessible Parking Space Serving South Picnic Area and Park Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
3738
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
3737
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
7 POT from Accessible Parking Space to Picnic Area
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4771, Packet Page 4976 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Cross Section
Project Year:

Funding source:

Project:
505.7
16 LF $75 $1,200
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
3748
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Handrail
Project Year:

Funding source:

Project:
505.10.3
1 JOB $230 $230
9" protrusion at 33" AFF
PCODE ED12 Bottom extension of handrail does not return creating a hazard for blind individuals.

Remodel handrail return.
• As-Built Description:
• Proposed Solution:
• As-Built:
3750
TBD
ADAAG 4.9.4(6)
CSAS 1133B.4.2.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.4
PCODE WD06NT 1 JOB $600 $600
Faucet at drinking fountain requires twisting.

Provide accessible lever handle at drinking
fountain.
• As-Built Description:
• Proposed Solution:
3745
TBD
ADAAG 4.19.5
CSAS 1115B.4.3
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
5" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
3749
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 30 LF $9 $270
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
3747
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
8 POT from Picnic Area to Play Structure
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4772, Packet Page 4977 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Cross Section
Project Year:

Funding source:

Project:
505.7
32 LF $75 $2,400
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
3751
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Top & Bottom Extension at Stairs
Project Year:

Funding source:

Project:
505.10.2; 505.10.3
REF
8" extensions
PCODE ED06REF Stair handrail does not extend horizontally 12" minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.

Extend stair handrail at top and bottom (cost for
each extension piece).
• As-Built Description:
• Proposed Solution:
• As-Built:
3752
TBD
ADAAG 4.9.4(2)
CSAS 1133B.4.2.2
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 70 LF $9 $630
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
3753
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
10 Men's Restroom and Shower
Accessories
Project Year:

Funding source:

Project:
308.2.1
5 JOB $100 $500
SD: 47" AFF
EHD: 50" AFF
EHD: 77" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3765
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150

48.5" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
3766
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4773, Packet Page 4978 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
65" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3772
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
3768
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3769
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 2 JOB $100 $200
Stall doors (shower stall & toilet stall) do not have
accessible operating hardware (U-pulls on both
sides, flip-over or sliding lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
3777
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
11 Women's Restroom and Shower
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4774, Packet Page 4979 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Accessories
Project Year:

Funding source:

Project:
308.2.1
4 JOB $100 $400
SD: 45" AFF
EHD: 46" AFF
EHD: 65" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3794
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
603.3
1 JOB $150 $150
48" AFF
PCODE WG03 Bottom of flat, not tilted mirror more than 40" above floor.

Relocate or provide new accessible mirror.
• As-Built Description:
• Proposed Solution:
• As-Built:
3793
TBD
ADAAG 4.19.6
CSAS 1115B.8.1
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
66" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3795
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 1
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
3790
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3787
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4775, Packet Page 4980 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
3800
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
12 Camp Site Adjacent to Restrooms
Identification
Project Year:

Funding source:

Project:
502.6
PCODE EA04B 1 JOB $315 $315
Sign for accessible parking space is missing or noncompliant.

Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
3809
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
14 Women's Restroom and Shower
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3812
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3813
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
15 Men's Restroom and Shower
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4776, Packet Page 4981 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3817
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3818
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
16 Accessible Unisex Restroom Between Showers
Accessories
Project Year:

Funding source:

Project:
308.2.1
3 JOB $100 $300
EHD: 50" AFF
SD: 43" AFF
SCD: 48" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3829
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3822
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4777, Packet Page 4982 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3823
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Total Costs for Floor: On-Site $10,185.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4778, Packet Page 4983 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1033-0-1
Veterans Memorial Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Skyline Drive at Veterans Drive Building Maintenance Total Costs for Part: Exterior $10,185.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4779, Packet Page 4984 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance 1 Accessible Parking Adjacent to Tennis Court
Identification
Project Year:

Funding source:

Project:
502.6
PCODE EA04B 1 JOB $315 $315
Sign for accessible parking space is missing or noncompliant.

Provide compliant parking signage.
• As-Built Description:
• Proposed Solution:
3847
TBD
ADAAG 4.6.4
CSAS 1129B.4
Severity 4
Priority 1
ADA-2010
General Fund
General Maintenance
Parking
Project Year:

Funding source:

Project:
208.2; 502.1
PCODE EA07 1 JOB $350 $350
No van parking provided (one in every 8 accessible
spaces, but not less than one, 8' wide access aisle to
the right of the parking stall, 98" height clearance).

Provide van parking space(s) by restriping; provide
van sign.
• As-Built Description:
• Proposed Solution:
3849
TBD
ADAAG 4.1.2(5)(b)
CSAS 1129B.3.2
Severity 2
Priority 1
ADA-2010
General Fund
General Maintenance
Parking Signage
Project Year:

Funding source:

Project:

PCODE EA04C 1 JOB $325 $325
No "Tow Away" sign at parking lot entrance
(required in CA only).

Provide "Tow Away" sign at parking lot entrance
when altering area.
• As-Built Description:
• Proposed Solution:
3846
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE EA04G 1 JOB $100 $100
CA only: Additional Sign or additional language
below the symbol of accessibility stating
“Minimum Fine $250” not provided.

Provide compliant parking signage that includes
fine information.
• As-Built Description:
• Proposed Solution:
3850
TBD CSAS 1129B.4
Severity 4
Priority 5
General Fund
General Maintenance
2 POT from Acc. Parking to Tennis Court West Gate Entrance Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
3854
TBD
CSAS 1133B.2.6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
4 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4780, Packet Page 4985 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Accessible Compartment
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05D 1 JOB $500 $500
The location of the stall door is not in front of the
clear space (next to the water closet), with a
maximum stile width of 4 ".

Remodel compartment.
• As-Built Description:
• Proposed Solution:
3866
TBD
ADAAG 4.17.3 & Fig. 30(a)
CSAS 1115B.3.1.4.3
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Accessories
Project Year:

Funding source:

Project:
3 JOB $100 $300
SD: 43" AFF
SCD: 45" AFF
BCS: 48" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3862
TBD CSAS 1115B.8.3
Severity 2
Priority 5
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
61" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3873
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $1,200 $1,200
29" x 59"
PCODE WD01NT Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Modify partition/privacy screen
• As-Built Description:
• Proposed Solution:
• As-Built:
3861
TBD
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3857
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4781, Packet Page 4986 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3858
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500

33.5" clear opening width
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
3878
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05CNT 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
3864
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
5 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
308.2.1
2 JOB $100 $200
SD: 44" AFF
SCD: 49" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
3883
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4782, Packet Page 4987 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
58" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
3884
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.5
PCODE WD05 1 JOB $120 $120
Hot or sharp-surfaced water/drain pipe not insulated
or covered.

Insulate or cover water/drain pipe.
• As-Built Description:
• Proposed Solution:
3885
TBD
ADAAG 4.19.4
CSAS 1115B.4.3.4
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
3880
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
3881
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
1 JOB $1,500 $1,500
32" clear opening width
PCODE WB05 Stall door opening less than 32" clear (CA only: ... or less than 34" at side entry door).

Provide new partition and stall door with compliant
width.
• As-Built Description:
• Proposed Solution:
• As-Built:
3896
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4783, Packet Page 4988 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide U-pull at inside of stall door.
• As-Built Description:
• Proposed Solution:
3888
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
6 POT from Restroom Building to East Tennis Court Gate Entrance Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 1 JOB $180 $180
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
3899
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
9 North Pathway Along Park
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 1 JOB $170 $170
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign toward dugout.
• As-Built Description:
• Proposed Solution:
3913
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 1 General Fund
General Maintenance
11 Baseball Dugout and Bleacher
Gate
Project Year:

Funding source:

Project:
404.2.10
PCODE ID06B 2 JOB $180 $360
10" min kick-plate/accessible operating hardware at
gate not provided on push-side of gate and/or gap
between floor surface and bottom of gate exceeds
3” max. (required in CA only).

Provide accessible operating hardware and 10" min.
"kick plate" covering width of gate when altering
area.
• As-Built Description:
• Proposed Solution:
3918
TBD
CSAS 1133B.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
13 Stairs to Upper Picnic Area
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4784, Packet Page 4989 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Cross Section
Project Year:

Funding source:

Project:
505.7
100 LF $75 $7,500
2" wide
PCODE ED03 Standard handrail: Gripping section narrower than 1-1/4" or wider than 1-1/2".

Provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
3927
TBD
ADAAG 4.26.2
CSAS 1133B.4.2.6
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Handrail
Project Year:

Funding source:

Project:
505.10.3
REF
Protrusion at 32" AFG
PCODE ED12REF Bottom extension of handrail does not return creating a hazard for blind individuals.

Remodel handrail return.
• As-Built Description:
• Proposed Solution:
• As-Built:
3928
TBD
ADAAG 4.9.4(6)
CSAS 1133B.4.2.3
Severity 3
Priority 2
ADA-2010
General Fund
General Maintenance
Height
Project Year:

Funding source:

Project:
505.4
REF
32"
PCODE ED02REF Handrail gripping surface top not mounted between 34" and 38" above ramp surface or stair nosings.

Remove existing and provide new handrail.
• As-Built Description:
• Proposed Solution:
• As-Built:
3926
TBD
ADAAG 4.9.4(5)
CSAS 1133B.4.2.1 & B.5.5.1
Severity 4
Priority 2
ADA-2010
General Fund
General Maintenance
Route Sign
Project Year:

Funding source:

Project:

PCODE SA20 2 JOB $170 $340
No sign by inaccessible route directing persons to
an accessible route.

Provide directional sign at to and bottom directing
people to accessible parking lot provided at each
area.
• As-Built Description:
• Proposed Solution:
3923
TBD
ADAAG 35.163(b)
CSAS 1127B.3
Severity 4
Priority 2 General Fund
General Maintenance
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 120 LF $9 $1,080 Contrasting color strip not provided at all stair nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
3925
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
14 Parking Lot Serving Upper Picnic Area
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4785, Packet Page 4990 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Minimum Number
Project Year:

Funding source:

Project:
208.2
PCODE EA01A 1 JOB $300 $300
At parking lot with 1-25 spaces, the number of
accessible spaces is less than required by code; 1
space required
Provide required accessible parking space with sign
including a minimum of one van space.
• As-Built Description:
• Proposed Solution:
3929
TBD
ADAAG 4.1.2(5)
CSAS Tbl. 11B-6
Severity 3
Priority 1
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $17,180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4786, Packet Page 4991 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1034-0-1
Via Pariaso Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Via Pariaso & Herrmann Dr. Building Maintenance Total Costs for Part: Exterior $17,180.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4787, Packet Page 4992 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance 2 POT from Park Entrance to Picnic Tables
Operable Part
Project Year:

Funding source:

Project:
309.4
2 JOB $300 $600
9 lbs
PCODE IC02 Operable part(s) require tight grasping, pinching, or twisting of the wrist with one hand.

Modify or replace the operable part(s) to not require
tight grasping, pinching, or twisting of the wrist
with one hand.
• As-Built Description:
• Proposed Solution:
• As-Built:
4043
TBD
ADAAG 4.27.4
CSAS 1117B.6.4
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
5 POT from Driveway to Amphitheater
Tread Surface
Project Year:

Funding source:

Project:
504.4
PCODE EC02 64 LF $9 $576
Contrasting color strip not provided at all stair
nosings (required in CA only).

Provide contrasting color strips at all exterior stair
treads.
• As-Built Description:
• Proposed Solution:
4053
TBD
CSAS 1133B.4.4
Severity 4
Priority 5
ADA-2010
General Fund
General Maintenance
9 POT from Covered Picnic Area to Barbecue and Drinking Fountain Drinking Fountain
Project Year:

Funding source:

Project:
602.2
PCODE IA02NT 1 JOB $3,200 $3,200 Wall- and post-mounted cantilevered units: Knee space not provided at drinking fountain (27" high,
8" deep, 30" wide from front of drinking fountain).

Provide new, accessible fountain.
• As-Built Description:
• Proposed Solution:
4066
TBD
ADAAG 4.15.5(1)
CSAS 1115B.4.6.2
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
10 Men's Restroom (West)
Accessories
Project Year:

Funding source:

Project:
1 JOB $100 $100
EHD: 43" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
4076
TBD CSAS 1115B.8.3
Severity 4
Priority 5
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4788, Packet Page 4993 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
61" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4071
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11AREF REF
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign with raised letters
and pictogram, mounted 5' high on center on
nearest adjacent wall, on latch side if a single door.
• As-Built Description:
• Proposed Solution:
4070
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4068
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
11 Women's Restroom (West)
Accessories
Project Year:

Funding source:

Project:
1 JOB $100 $100
EHD: 43" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
4080
TBD CSAS 1115B.8.3
Severity 4
Priority 5
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
59" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4081
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4789, Packet Page 4994 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11AREF REF
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign with raised letters
and pictogram, mounted 5' high on center on
nearest adjacent wall, on latch side if a single door.
• As-Built Description:
• Proposed Solution:
4079
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4077
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4084
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
12 Men's Restroom (East)
Accessories
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
EHD: 55" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
4092
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4790, Packet Page 4995 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
61" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4095
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4090
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4089
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4096
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Toilet Stall
Project Year:

Funding source:

Project:
604.8.1.1
1 JOB $1,500 $1,500
59" wide
PCODE WB06 Toilet stall less than 60" wide due to curb.

Relocate stall partition to provide 60" wide stall and
maintain the required urinal clear floor space.
• As-Built Description:
• Proposed Solution:
• As-Built:
4101
TBD
ADAAG 4.17.3
CSAS 1115B.3.1.4.1
Severity 4
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4791, Packet Page 4996 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Turning Space
Project Year:

Funding source:

Project:
603.2.1
1 JOB $1,190 $1,190
61" x 58"
PCODE WC01 Wheelchair clearance: Clear space, floor to 27" high with a diameter of 60", not provided (space
56" x 63" acceptable).

Provide wheelchair clearance space in restroom by
shorten the partition wall between urinal and
lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4094
TBD
ADAAG 4.22.3
CSAS 1115B.3.1
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
13 Women's Restroom (East)
Accessories
Project Year:

Funding source:

Project:
308.2.1
1 JOB $100 $100
EHD: 56" AFF
PCODE WG01A Dispensers in sanitary facilities, such as for towels, soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40") from
floor to highest operating slot or control.

Relocate existing restroom accessories.
• As-Built Description:
• Proposed Solution:
• As-Built:
4106
TBD
ADAAG 4.23.7
CSAS 1115B.8.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Coat Hook
Project Year:

Funding source:

Project:
603.4
1 JOB $50 $50
61" AFF
PCODE WG03A Accessible coat hook not within reach range.

Adjust existing or provide new coat hook at
maximum 48" height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4112
TBD
ADAAG 4.2.5
CSAS 1118B.5
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
Lavatory
Project Year:

Funding source:

Project:
606.2
1 JOB $3,400 $3,400
29" wide
PCODE WD01 Clear floor space, 30" x 48" in front of fixture, extending 19" max. under the lavatory, not
provided (CA only: Less than 18" from side wall to
centerline of lavatory).

Relocate adjacent partition to provide 30" x 48" in
front of lavatory.
• As-Built Description:
• Proposed Solution:
• As-Built:
4105
TBD
ADAAG 4.19.3
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
General Maintenance
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4792, Packet Page 4997 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Signage
Project Year:

Funding source:

Project:
216.8
PCODE SA11A 1 JOB $90 $90
Entrance to toilet or bathing facility identified with
California signage on door leaf not identified with
ADAAG compliant signage.

Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
• As-Built Description:
• Proposed Solution:
4103
TBD
ADAAG 4.1.3(16)(a)
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Project Year:

Funding source:

Project:

PCODE SA15 1 JOB $90 $90
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provided (women: 12" ø circle, men: 12" triangle,
unisex: combined symbol).

Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
• As-Built Description:
• Proposed Solution:
4102
TBD CSAS 1115B.6
Severity 3
Priority 5
General Fund
General Maintenance
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05C 1 JOB $100 $100
Stall door does not have accessible operating
hardware (U-pulls on both sides, flip-over or sliding
lock).

Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and Upulls on both sides. • As-Built Description:
• Proposed Solution:
4113
TBD
ADAAG 4.17.5
CSAS 1115B.3.1.4.5
Severity 3
Priority 3
ADA-2010
General Fund
General Maintenance
Total Costs for Floor: On-Site $11,906.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4793, Packet Page 4998 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Total Costs for Part: Exterior $11,906.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4794, Packet Page 4999 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1035-0-1
Whispering Pine Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Pacific & Alameda Streets Building Maintenance Total Costs for Funding: Building Maintenance $224,623.00 March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4795, Packet Page 5000 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
2 SW Curb Ramp at Cypress and Hoffman Serving Park
Detectable Warnings
Project Year:

Funding source:

Project:
705.1
PCODE PC53DREF REF
No detectable warning surface provided where a
curb ramp, landing, or blended transition connects
to a street.

Install a truncated dome surface extending 24" min
in the direction of travel and the full width of the
curb ramp, landing, or blended transition that is
flush with the street.
• As-Built Description:
• Proposed Solution:
2341
2011-12
ADAAG 4.7.7
Severity 3
Priority 1
PROW R303.3.2
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Gutter
Project Year:

Funding source:

Project:
406.2
REF

10.3%
PCODE PC70DREF The slope of the gutter area or street at the foot of a curb ramp or blended transition exceeds 1:20 (5%)
in the direction of the pedestrian crossing.

Demolish gutter or street area as required and
provide new gutter with 5% max slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2340
2011-12
ADAAG 4.7.2
CSAS 1127B.5.3
Severity 2
Priority 1
PROW R303.3.5
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Ramp Landing
Project Year:

Funding source:

Project:
405.7
PCODE PC05AREF REF
Top landing at existing perpendicular curb ramp is
less than 48" x 48" (60" length x ramp width
preferred).

Demolish existing and provide new, perpendicular
curb ramp, including detectable warning surfaces,
and top and bottom landings as required.
• As-Built Description:
• Proposed Solution:
2342
2011-12
ADAAG 4.8.4(1)
CSAS 1127B.5.4
Severity 3
Priority 1
PROW R303.2.1.3
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Ramp Slope
Project Year:

Funding source:

Project:
405.2
REF

9.0%
PCODE PC03CREF Running slope of existing perpendicular curb ramp is less than 5% or more than 8.3%.

Demolish existing and provide new, blended
transition, including detectable warning surfaces,
and top and bottom landings as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
2339
2011-12
ADAAG 4.7.2; 4.8.2
CSAS 1127B.5.3
Severity 4
Priority 1
PROW R303.2.1.1
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4796, Packet Page 5001 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
Project Year:

Funding source:

Project:
405.3
1 JOB $2,800 $2,800

13.2%
PCODE PC04A Cross slope of an existing perpendicular curb ramp exceeds 1:48 (2%).

Demolish existing and provide new, perpendicular
curb ramp, including detectable warning surfaces,
and top and bottom landings as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
2338
2011-12
ADAAG 4.8.6
Severity 3
Priority 1
PROW R303.2.1.2
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Total Costs for Floor: On-Site $2,800.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4797, Packet Page 5002 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
Total Costs for Part: Exterior $2,800.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4798, Packet Page 5003 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues CIP - General Fund 4 POT from Press Box Building Gate to Park Entrance at Encina Avenue Detectable Warnings
Project Year:

Funding source:

Project:
705.1
PCODE PC53DREF REF
No detectable warning surface provided where a
curb ramp, landing, or blended transition connects
to a street.

Install a truncated dome surface extending 36" min
in the direction of travel and the full width of the
curb ramp, landing, or blended transition that is
flush with the street.
• As-Built Description:
• Proposed Solution:
4284
2011-12
ADAAG 4.7.7
Severity 3
Priority 1
PROW R303.3.2
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Gutter
Project Year:

Funding source:

Project:
406.2
REF

7.1%
PCODE PC70DREF The slope of the gutter area or street at the foot of a curb ramp or blended transition exceeds 1:20 (5%)
in the direction of the pedestrian crossing.

Demolish gutter or street area as required and
provide new gutter with 5% max slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4283
2011-12
ADAAG 4.7.2
CSAS 1127B.5.3
Severity 4
Priority 1
PROW R303.3.5
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Ramp Flare
Project Year:

Funding source:

Project:

REF
L flare: 13.2%
R flare: 10.3%
PCODE PC08AREF Slope of flare(s) along curb at perpendicular curb ramp exceed(s) 10%.

Demolish existing and provide new, perpendicular
curb ramp, including detectable warning surfaces,
and top and bottom landings as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
4282
2011-12 CSAS 1127B.5.3
Severity 3
Priority 1
PROW R303.2.1.4
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Ramp Landing
Project Year:

Funding source:

Project:
405.7
PCODE PC05AREF REF
Top landing at existing perpendicular curb ramp is
less than 48" x 48" (60" length x ramp width
preferred).

Demolish existing and provide new, perpendicular
curb ramp, including detectable warning surfaces,
and top and bottom landings as required.
• As-Built Description:
• Proposed Solution:
4281
2011-12
ADAAG 4.8.4(1)
CSAS 1127B.5.4
Severity 2
Priority 1
PROW R303.2.1.3
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4799, Packet Page 5004 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues CIP - General Fund Ramp Slope
Project Year:

Funding source:

Project:
405.2
1 JOB $3,000 $3,000

13.0%
PCODE PC03B Running slope of existing perpendicular curb ramp is less than 5% or greater than 8.3%.

Demolish existing and provide new, parallel curb
ramp, including detectable warning surfaces, and
top and bottom landings as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
4280
2011-12
ADAAG 4.7.2; 4.8.2
CSAS 1127B.5.3
Severity 3
Priority 1
PROW R303.2.1.1
ADA-2010
Gas Tax
City ADA Transition Plan Upgrade
- Intersections
Total Costs for Floor: On-Site $3,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4800, Packet Page 5005 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues CIP - General Fund Total Costs for Part: Exterior $3,000.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4801, Packet Page 5006 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
3 Sidewalk Along Cypress
Continuous Access Route
Project Year:

Funding source:

Project:

PCODE PR02B 1000 LF $60 $60,000 Pedestrian access route does not exist.

Provide an accessible connection between the
pedestrian route and elements required to be
accessible.
• As-Built Description:
• Proposed Solution:
2343
2011-12
ADAAG 4.1.2 (1) & (2)
Severity 3
Priority 1
PROW R301.2
Gas Tax
Upgrade City Pavement
Management Program
6 POT from Cypress St. to Tennis Court
Access Route
Project Year:

Funding source:

Project:

PCODE PC01A 1 JOB $2,800 $2,800 Curb ramp or blended transition not provided where a pedestrian access route crosses a curb.

Provide a perpendicular curb ramp, including
detectable warning surfaces, and top and bottom
landings as required.
• As-Built Description:
• Proposed Solution:
2351
2011-12
ADAAG 4.7.1
CSAS 1127B.5.1
Severity 3
Priority 1
PROW R303.1 Gas Tax
Upgrade City Pavement
Management Program
Total Costs for Floor: On-Site $62,800.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4802, Packet Page 5007 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
Total Costs for Part: Exterior $62,800.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4803, Packet Page 5008 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues CIP - General Fund 4 POT from Press Box Building Gate to Park Entrance at Encina Avenue Changes in Level
Project Year:

Funding source:

Project:

REF
5"
PCODE PC67REF 12" wide grooved border not provided (CA
requirement only).

Provide 12" wide grooved border per CA code
when remodeling
• As-Built Description:
• Proposed Solution:
• As-Built:
4285
2011-12 CSAS 1127B.5.6
Severity 1
Priority 5
Gas Tax
Upgrade City Pavement
Management Program
Cross Slope
Project Year:

Funding source:

Project:
403.3
100 SF $40 $4,000

2.3% - 2.4%
PCODE PR05A The cross slope of the pedestrian access route exceeds the maximum required slope (1:48 max).

Modify existing route as necessary to not exceed
the required 1:48 (2%) maximum cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4279
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
Project Year:

Funding source:

Project:
403.3
150 SF $40 $6,000

2.4% - 2.8%
PCODE PR05A The cross slope of the pedestrian access route (sidewalk between stop sign and gate entrance)
exceeds the maximum required slope (1:48 max).

Modify existing route as necessary to not exceed
the required 1:48 (2%) maximum cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4286
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
POT from Park Entrance at Encina Ave. to Group Picnic at Corner of Del Robles Ave.
10 Cross Slope
Project Year:

Funding source:

Project:
403.3
125 SF $40 $5,000

2.6% - 3.2%
PCODE PR05A The cross slope of the pedestrian access route (1st 5 sections of sidewalk) exceeds the maximum
required slope (1:48 max).

Modify existing route as necessary to not exceed
the required 1:48 (2%) maximum cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4347
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4804, Packet Page 5009 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues CIP - General Fund Project Year:

Funding source:

Project:
403.3
150 SF $40 $6,000

2.5% - 3.0%
PCODE PR05A The cross slope of the pedestrian access route (sidewalk between fence post adjacent to tool shed
and storm drain) exceeds the maximum required
slope (1:48 max).

Modify existing route as necessary to not exceed
the required 1:48 (2%) maximum cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4348
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
Cross Slope (Driveway)
Project Year:

Funding source:

Project:
403.3
105 SF $40 $4,200

8.2%
PCODE PR10A The cross slope of the pedestrian access route in a driveway exceeds the maximum required slope
(1:48).

Modify the driveway to provide a slope not
exceeding the required 1:48 (2%) maximum slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4350
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
Total Costs for Floor: On-Site $25,200.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4805, Packet Page 5010 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1010-0-1
Peter J. Ferrante Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Encina and Palo Verde Avenues CIP - General Fund Total Costs for Part: Exterior $25,200.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4806, Packet Page 5011 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street CIP - General Fund
1 West Park Entrance
Cross Slope (Driveway)
Project Year:

Funding source:

Project:
403.3
24 SF $12 $288

9.7%
PCODE PR10B The cross slope of the pedestrian access route in a driveway exceeds the maximum required slope
(1:48).

Create an alternative path around the driveway to
provide a slope not exceeding the required 1:48
(2%) maximum slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2263
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 1
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
5 South Park Entrance Stairs
Protruding Object
Project Year:

Funding source:

Project:
307.4
PCODE PS25A 1 JOB $400 $400
Slanted utility guy wire adjacent to accessible route
walkway creates overhead obstruction between 27"
and 80" from surface.

Provide guy brace to vertically align guy wire
within 80" height from walkway surface.
• As-Built Description:
• Proposed Solution:
2276
2011-12
ADAAG 4.4.2, 4.3.5
CSAS 1133B.8.2
Severity 3
Priority 2
PROW R401.4
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
6 POT from East Park Entrance to Baseball Field
Cross Slope
Project Year:

Funding source:

Project:
403.3
REF
6% - 7%
PCODE PR05AREF The cross slope of the pedestrian access route exceeds the maximum required slope (1:48 max).

Modify existing route as necessary to not exceed
the required 1:48 (2%) maximum cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2278
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 1
PROW R301.4.1
ADA-2010
Gas Tax
Upgrade City Pavement
Management Program
Total Costs for Floor: On-Site $688.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4807, Packet Page 5012 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1019-0-1
Larkin Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monroe & Clay Street CIP - General Fund
Total Costs for Part: Exterior $688.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4808, Packet Page 5013 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
1 Parking Spaces Serving Archer Park
Curb Ramp
Project Year:

Funding source:

Project:
406.1
PCODE EH01 1 JOB $2,500 $2,500 No curb ramp available where an accessible route crosses a curb.

Provide new parallel curb ramp within the 18' long
access aisle.
• As-Built Description:
• Proposed Solution:
2721
2011-12
ADAAG 4.7.1
CSAS 1127B.5.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
2 POT from Parking Spaces to Play Structure Entrance
Door
Project Year:

Funding source:

Project:

PCODE ID06 1 JOB $100 $100
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface
(required in CA only).

Provide 10" min. "kick plate" covering width of
door when altering area.
• As-Built Description:
• Proposed Solution:
2723
2011-12 CSAS 1133B.2.6
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
15 SF $40 $600

4.7%
PCODE ID11 Surface of required maneuvering clearance at door slopes more than 1/4":12" (2.0%).

Modify surface slope at door.
• As-Built Description:
• Proposed Solution:
• As-Built:
2725
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
3 POT from Play Structure Entrance to Play Structure
Play Structure
Project Year:

Funding source:

Project:

PCODE OC01 1 JOB $1,500 $1,500 A transfer platform is not provided onto a play structure from an accessible route.

Provide transfer platform at play structure.
• As-Built Description:
• Proposed Solution:
2728
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE OC01AREF REF
A 60" x 60" clear area is not provided on at least
one side of the transfer platform.

Provide space as required.
• As-Built Description:
• Proposed Solution:
2729
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4809, Packet Page 5014 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Project Year:

Funding source:

Project:

PCODE OC01BREF REF
A wheelchair parking space, 30" x 48" min., is not
provided and/or is located within 8' of play
equipment or in path of travel.

Provide space as required, hard-surfaced with
access to path of travel.
• As-Built Description:
• Proposed Solution:
2730
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
REF

3.3% - 4.5%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2727
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
300 SF $25 $7,500

3.5% - 6.7%
PCODE EF01 Brick Paver Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for
ramps.

Modify brick paver walk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
2726
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 POT from Play Structure Entrance to Picnic Area
Clear Width
Project Year:

Funding source:

Project:
403.5.1
480 SF $45 $21,600
40"
PCODE EF08A Walk less than 36" wide.

Enlarge width of walk to 48".
• As-Built Description:
• Proposed Solution:
• As-Built:
2733
2011-12
ADAAG 4.3.3
CSAS 1133B.7.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Fixed Bench
Project Year:

Funding source:

Project:
903.2
PCODE NO07NT 1 JOB $100 $100
Bench is not connected to an access route and clear
floor or ground space (30" x 48") not overlapping
with other clear space requirements, is not provided
at at least one end of the bench.

Provide connection to bench access route and
position clear floor or ground space to allow
wheelchair users to be seated shoulder-to-shoulder
with an individual seated on the bench.
• As-Built Description:
• Proposed Solution:
2736
2011-12
ADAAG 16.12.4
CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4810, Packet Page 5015 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Picnic Area
Project Year:

Funding source:

Project:

PCODE NH02 9 LF $45 $405
Single fixed picnic table is not connected to an
outdoor recreation access route.

Provide connection to recreation access route.
• As-Built Description:
• Proposed Solution:
2734
2011-12
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
902.2
1 JOB $850 $850
26" high x 28" wide x 12" deep
PCODE NH11B Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Replace inaccessible picnic table with new
accessible, providing knee clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
2737
2011-12
ADAAG 4.32.3
CSAS 1122B.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
REF

5.6% - 7.1%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope when remodeling brick paver
walk from metal gate entrance to play structure.
• As-Built Description:
• Proposed Solution:
• As-Built:
2731
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.3
REF

5.8% - 7.2%
PCODE EF07REF Walk adjacent to tree cross slope more than 1/4":12" (2%).

Modify cross slope when fixing width of walk
within play structure area.
• As-Built Description:
• Proposed Solution:
• As-Built:
2732
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
REF

5.3% - 7.8%
PCODE EF01REF Walk connecting bridge structure stair: Slope greater than 1:20 (5.0%), and walk does not comply
with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less when
fixing width of walk within play structure area.
• As-Built Description:
• Proposed Solution:
• As-Built:
2735
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Unisex Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4811, Packet Page 5016 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Accessories
Project Year:

Funding source:

Project:
604.7
PCODE WG02 1 JOB $75 $75
Toilet paper dispenser (center line) less than 19" or
more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
2751
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
4" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
2741
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 4
Priority 5 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $200 $200
45"
PCODE WG04 Electric hand dryer mounted with control higher than 40" above floor.

Remount hand dryer at accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2745
2011-12
ADAAG 28 CFR 35.133(a)
CSAS 1115.B.9.2
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Door
Project Year:

Funding source:

Project:

PCODE ID15NT 1 JOB $750 $750
Front approach: less than 60" clear space
perpendicular to closed door at swing side.

Demolish partition and patch finishes.
• As-Built Description:
• Proposed Solution:
2742
2011-12
ADAAG Fig. 25
CSAS 1133B.2.4.2
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Drinking Fountain
Project Year:

Funding source:

Project:

PCODE IA05C 1 JOB $500 $500
Drinking fountain lacks protection for visually
impaired persons.

Provide cane-detectable rails.
• As-Built Description:
• Proposed Solution:
2738
2011-12
ADAAG 4.4.1
CSAS 1115B.4.6.3
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4812, Packet Page 5017 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Grab Bars
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 43" from rear wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
2748
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5
1 JOB $260 $260
34"
PCODE WB07C Grab bars not at 33" to 36" from floor (CA only:
33" from floor if no tank toilet).

Relocate accessible grab bars.
• As-Built Description:
• Proposed Solution:
• As-Built:
2752
2011-12
ADAAG 4.16.4
CSAS 1115B.4.1.3.1 & 2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75
SCD: 9" above RGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
2753
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 25" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
2747
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Toilet Stall
Project Year:

Funding source:

Project:
1 JOB $2,000 $2,000
26"
PCODE WB01 CA only: Less than 32" from side of water closet to far side of stall wall or 28" to adjacent fixture.

Relocate water closet. Remodel restroom as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
2750
2011-12 CSAS 1115B.4.1.1
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4813, Packet Page 5018 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Water Closet
Project Year:

Funding source:

Project:
604.6
PCODE WB10 1 JOB $500 $500
Flush Control: Operating handle not mounted
toward wide side of stall.

Replace flush control with properly mounted
accessible type, or install sensor flush.
• As-Built Description:
• Proposed Solution:
2749
2011-12
ADAAG 4.16.5
CSAS 1115B.4.1.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 POT from Unisex Restroom to Lower BBQ Area
Picnic Area
Project Year:

Funding source:

Project:

PCODE NH02 80 LF $45 $3,600 Single fixed picnic table is not connected to an outdoor recreation access route.

Provide connection to recreation access route.
• As-Built Description:
• Proposed Solution:
2758
2011-12
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
902.2
1 JOB $850 $850
29" high x 28" wide x 9" deep
PCODE NH11B Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Replace inaccessible picnic table with new
accessible, providing knee clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
2759
2011-12
ADAAG 4.32.3
CSAS 1122B.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Ramps
Project Year:

Funding source:

Project:
303.4
PCODE EB01A 480 SF $100 $48,000 Ramp needed to provide disabled access at steps or change of level along path of travel.

Provide new concrete ramp with handrails [slope
more than 1:20 (5.0%) needed].
• As-Built Description:
• Proposed Solution:
2757
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
REF

5.2% - 12.8%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2756
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 1
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4814, Packet Page 5019 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Walk
Project Year:

Funding source:

Project:
403.3
REF

8.2% - 12.3%
PCODE EF01REF Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
2755
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 Site Entry Stair at Spencer Street (Staff Only)
Stairs
Project Year:

Funding source:

Project:
504.2
REF
10" tread
PCODE EC06REF Stair tread width less than 11", measured horizontally from nosing to nosing.

Rebuild stair as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
2763
2011-12
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 4
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Treads and Risers
Project Year:

Funding source:

Project:
504.2
REF
5" to 7"
PCODE EC07AREF Steps do not have uniform riser height.

Remodel stairs as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
2761
2011-12
CSAS 1133B.4.5.3
Severity 3
Priority 4
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $93,805.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4815, Packet Page 5020 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1001-0-1
Archer Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 542 Archer St. CIP - General Fund
Total Costs for Part: Exterior $93,805.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4816, Packet Page 5021 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
1 Accessible Parking Space Serving Park and Center
Fixed Bench
Project Year:

Funding source:

Project:
903.2
PCODE NO07 1 JOB $500 $500
Clear floor or ground space (30" x 48") not
overlapping with other clear space requirements, is
not provided at at least one end of the bench near
sidewalk at Ramona Avenue.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
4361
2011-12
ADAAG 4.32.2
CSAS 1118B.4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Floor or Ground Surfaces
Project Year:

Funding source:

Project:
502.4
PCODE EA05 72 SF $12 $864
Lower portion of existing accessible parking space
has slope greater than 1/4":12" (2%).

Modify slope at accessible parking space.
• As-Built Description:
• Proposed Solution:
4360
2011-12
ADAAG 4.6.3
CSAS 1129B.3.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Parking
Project Year:

Funding source:

Project:
502.3
PCODE EA02BNT 1 JOB $1,000 $1,000 Accessible parking space does not have 5' wide access aisle; 8' wide for van accessible aisle (CA
only: aisle spaces need to be 18' in length).

Install accessible aisle at adjacent lawn area.
• As-Built Description:
• Proposed Solution:
4356
2011-12
ADAAG 4.6.3
CSAS 1129B.3.1
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE EA04D 1 JOB $100 $100
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle
(12" min high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).

Provide the words “NO PARKING” in each access
aisle, painted in 12” high letters, when altering area. • As-Built Description:
• Proposed Solution:
4357
2011-12 CSAS 1129B.3.1
Severity 4
Priority 5
General Fund
City ADA Transition Plan Upgrade
2 POT from Acc. Parking Space to Slide Play Structure Entrance Gate March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4817, Packet Page 5022 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Door
Project Year:

Funding source:

Project:
404.2.4
30 SF $40 $1,200

4.6%
PCODE ID11 Surface of required maneuvering clearance at pull side of gate slopes more than 1/4":12" (2.0%).

Modify surface slope at gate.
• As-Built Description:
• Proposed Solution:
• As-Built:
4370
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.4
30 SF $40 $1,200
10%
PCODE ID11 Surface of required maneuvering clearance at pushside of gate slopes more than 1/4":12" (2.0%).

Modify surface slope at gate.
• As-Built Description:
• Proposed Solution:
• As-Built:
4371
2011-12
ADAAG 4.13.6
CSAS 1133B.2.4
Severity 1
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
404.2.7
REF
51" AFG
PCODE ID17REF Door lock or latch more than 48" above the floor (CA only: 30" to 44").

Relocate or replace existing hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
4369
2011-12
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Slope
Project Year:

Funding source:

Project:
403.3
68 SF $25 $1,700

6.1% - 7.9%
PCODE EF07 Asphalt concrete walk cross slope more than
1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4365
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
405.1
30 LF $260 $7,800

4.3% - 9.3%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
4363
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE EF08REF REF
Walk more than 36" but less than 48" wide
(required in CA only) due to vegetation adjacent to
tree.

Remove and maintain vegetation area to provide
required 48" wide walk.
• As-Built Description:
• Proposed Solution:
4362
2011-12 CSAS 1133B.7.1
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4818, Packet Page 5023 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Project Year:

Funding source:

Project:

PCODE EF08REF REF
Sloped walk between preschool gate and asphalt
concrete paving more than 36" but less than 48"
wide (required in CA only) .

Enlarge width of walk to 48".
• As-Built Description:
• Proposed Solution:
4364
2011-12 CSAS 1133B.7.1
Severity 3
Priority 5
General Fund
City ADA Transition Plan Upgrade
3 Slide Play Structure
Fixed Bench
Project Year:

Funding source:

Project:
903.2
PCODE NO07REF REF
Clear floor or ground space (30" x 48") not
overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
4374
2011-12
ADAAG 16.12.4
CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Play Structure
Project Year:

Funding source:

Project:
1008.3.1.1
REF
29" x 13"
PCODE OC01C Transfer platform is smaller than 24" wide x 14" minimum deep.

Provide space as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
4372
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1008.3.1.4
PCODE OC01E 1 JOB $125 $125
At least one handhold, 25"-27" above the ground
surface needs to be provided -- or the transfer
platform needs an edge that can be gripped.

Provide handhold or transfer supports.
• As-Built Description:
• Proposed Solution:
4373
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE OC04 1 JOB $225 $225
Grab bars are not provided where platform height
changes.

Provide grab bars.
• As-Built Description:
• Proposed Solution:
6114
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
4 POT from Slide Play Structure to Swing Play Structure Entrance Gate March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4819, Packet Page 5024 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Accessible Route
Project Year:

Funding source:

Project:
206.1
PCODE EF13NT 75 LF $45 $3,375 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

Install accessible path from resilient surfacing at
slide play structure along fence to resilient
surfacing at swing play structure.
• As-Built Description:
• Proposed Solution:
4375
2011-12
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Door
Project Year:

Funding source:

Project:
404.2.7
1 JOB $300 $300
45" AFG
PCODE ID17 Door lock or latch more than 48" above the floor (CA only: 30" to 44").

Relocate or replace existing hardware.
• As-Built Description:
• Proposed Solution:
• As-Built:
4377
2011-12
ADAAG 4.13.9
CSAS 1133B.2.5.2
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
POT from Swing Play Structure Entrance Gate to Lower Basketball Court
5 Walk
Project Year:

Funding source:

Project:
405.1
30 LF $260 $7,800

6.5% - 7.2%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
4380
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 POT from Basketball Court to Public Restrooms
Drinking Fountain
Project Year:

Funding source:

Project:
602.6
1 JOB $75 $75
1" high
PCODE IA03D Drinking fountain water flow less than 4" high; unit in good condition.

Adjust water flow.
• As-Built Description:
• Proposed Solution:
• As-Built:
4383
2011-12
ADAAG 4.15.3
CSAS 1115B.4.6.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE IA05C 1 JOB $500 $500
Drinking fountain lacks protection for visually
impaired persons.

Provide cane-detectable rails.
• As-Built Description:
• Proposed Solution:
4382
2011-12
ADAAG 4.4.1
CSAS 1115B.4.6.3
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4820, Packet Page 5025 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Slope
Project Year:

Funding source:

Project:
403.3
88 SF $25 $2,200

2.4% - 3.8%
PCODE EF07 Cross slope more than 1/4":12" (2%) at portion of asphalt concrete paving between planter and sloped
walk in front of men's restroom.

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4381
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
7 Men's Restroom
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
42" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
4396
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
4395
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Entry Door
Project Year:

Funding source:

Project:

PCODE WC03NT 1 JOB $460 $460
CA only: Restroom entry / exit door: 60" square
clear space not provided at door swing side.

Re-grade clear floor space at 2% max.
• As-Built Description:
• Proposed Solution:
4384
2011-12 CSAS 1115B.3.1.1
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 15" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5809
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4821, Packet Page 5026 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 40" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
4393
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75
TPD: 9" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
4394
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26.75" high;
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4397
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Stall Door
Project Year:

Funding source:

Project:
604.8.1.2
PCODE WB05B 1 JOB $25 $25
Stall door to accessible compartment not self
closing.

Adjust closer.
• As-Built Description:
• Proposed Solution:
4390
2011-12
ADAAG 4.22.4
CSAS 1115B.3.1.4.4
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
8 Women's Restroom
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4822, Packet Page 5027 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Accessories
Project Year:

Funding source:

Project:
604.7
1 JOB $75 $75
42" from rear wall
PCODE WG02 Toilet paper dispenser (center line) less than 19" or more than 40" above floor (CA only: not within 12"
from front of water closet and/or not within 36"
max. to the far edge from the rear wall).

Relocate or provide new toilet paper dispenser.
• As-Built Description:
• Proposed Solution:
• As-Built:
4411
2011-12
ADAAG 4.16.6
CSAS 1115B.8.4
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

REF
5" protrusion
PCODE WG02BREF Toilet paper dispenser or disposal container protrudes more than 3" out from side wall, into
clear 30" x 48" space in front of water closet.

Recommended: Provide recessed toilet paper
dispenser. (99-07 Formally Deleted 8/25/05)
• As-Built Description:
• Proposed Solution:
• As-Built:
4410
2011-12
ADAAG Fig. 28
CSAS 1133B.8.6.1
Severity 3
Priority 5 General Fund
City ADA Transition Plan Upgrade
Entry Door
Project Year:

Funding source:

Project:

PCODE WC03NT 1 JOB $460 $460
CA only: Restroom entry / exit door: 60" square
clear space not provided at door swing side.

Re-grade clear floor space at 2% max.
• As-Built Description:
• Proposed Solution:
4399
2011-12 CSAS 1115B.3.1.1
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
Grab Bars
Project Year:

Funding source:

Project:
604.5.1
1 JOB $260 $260
Starting at 15" from rear wall
PCODE WB07A Side grab bar less than 42" long, or located more than 12 inches max. from the rear wall, or
extending less than 54" from rear wall (CA only:
front end min. 24" in front of water closet).

Provide or relocate accessible side grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
5810
2011-12
ADAAG Fig. 29(b)
CSAS 1115B.4.1.3.1
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
604.5.2
1 JOB $340 $340
Extends 40" from side wall
PCODE WB07B Rear grab bar less than 36" long, or does not extend from the centerline of the water closet 12"
minimum on one side and 24" (Does not extend 42"
from side wall when WC is located at CA required
18" o.c.).

Provide accessible rear grab bar.
• As-Built Description:
• Proposed Solution:
• As-Built:
4408
2011-12
ADAAG 4.17.6
CSAS 1115B.4.1.3.2
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4823, Packet Page 5028 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Project Year:

Funding source:

Project:
609.3
1 JOB $75 $75
TPD: 9" above SGB
PCODE WB07I Accessories/dispensers in accessible stall located closer than 1-1/2" below or 18" above grab bar
impedes its use.

Relocate accessories/dispensers to be no closer than
1-1/2" below and 18" above grab bars (except if
accessories are recessed, flush with wall, and have
no sharp edges).
• As-Built Description:
• Proposed Solution:
• As-Built:
4409
2011-12
ADAAG 4.26.2
CSAS 1133B.4.2.5
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Lavatory
Project Year:

Funding source:

Project:
606.3
1 JOB $1,500 $1,500
Knee space: 26" high
PCODE WD04A Knee clearance 27" min. high starting 8" back from the front edge of the lavatory towards the wall is
not provided.

Remount compliant fixture to accessible height.
• As-Built Description:
• Proposed Solution:
• As-Built:
4406
2011-12
ADAAG Fig. 31
CSAS 1115B.4.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Protrusion Limits
Project Year:

Funding source:

Project:
307.2
1 JOB $100 $100
BCS: 4" protrusion at 28" AFF
PCODE EG04 Protruding objects more than 4" from wall, when bottom of object more than 27" or less than 80"
above finished floor.

Remove/relocate protruding object. Patch existing
surface.
• As-Built Description:
• Proposed Solution:
• As-Built:
4413
2011-12
ADAAG 4.4.1
CSAS 1133B.8.6.1
Severity 4
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Turning Space
Project Year:

Funding source:

Project:
603.2.1
PCODE WC01 1 JOB $1,190 $1,190 Wheelchair clearance: Clear space, floor to 27" high with a diameter of 60", not provided (space
56" x 63" acceptable).

Provide wheelchair clearance space in restroom.
• As-Built Description:
• Proposed Solution:
4414
2011-12
ADAAG 4.22.3
CSAS 1115B.3.1
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
9 POT from Public Restroom to Lower Barbecue / Picnic Area Slope
Project Year:

Funding source:

Project:
403.3
25 SF $25 $625

3.6%
PCODE EF07 Cross slope more than 1/4":12" (2%) at portion walk adjacent to downspout.

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4415
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4824, Packet Page 5029 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Walk
Project Year:

Funding source:

Project:
405.1
62 LF $260 $16,120

2.6% - 10.6%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
4417
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
10 Picnic / Barbecue Area
Cooking and Grills
Project Year:

Funding source:

Project:

PCODE NJ06REF REF
No min. 30" by 48" clear ground space for forward
or parallel approach to cook surface control.

Provide min. 30" by 48" clear ground space for
forward or parallel approach to cook surface
control.
• As-Built Description:
• Proposed Solution:
4421
2011-12
ADAAG 16.7.4, 2.7.2, 4.2.4.1
CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Picnic Area
Project Year:

Funding source:

Project:

PCODE NH02NT 20 LF $45 $900
Single fixed picnic table is not connected to an
outdoor recreation access route.

Provide connection to recreation access route at
picnic table, preparation table and grill stand.
• As-Built Description:
• Proposed Solution:
4420
2011-12
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Picnic Table
Project Year:

Funding source:

Project:
902.2
1 JOB $450 $450
12" deep
PCODE NH11A Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
4419
2011-12
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
11 Stairs from Upper Patio to Lower Picnic / Barbecue Area Open Risers
Project Year:

Funding source:

Project:
504.3
PCODE EC03 32 LF $36 $1,152 Stair does not have closed risers.

Modify stair to have closed risers
• As-Built Description:
• Proposed Solution:
4423
2011-12
ADAAG 4.9.2
CSAS 1133B.4.5.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
12 POT from Swing Play Structure Entrance Gate to Picnic Table at Lawn March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4825, Packet Page 5030 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Accessible Route
Project Year:

Funding source:

Project:
206.1
PCODE EF13 150 LF $45 $6,750 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

Provide new 48" wide pathway from entrance gate
to nearest picnic table.
• As-Built Description:
• Proposed Solution:
4425
2011-12
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Cooking and Grills
Project Year:

Funding source:

Project:

PCODE NJ06REF REF
No min. 30" by 48" clear ground space for forward
or parallel approach to cook surface control.

Provide min. 30" by 48" clear ground space for
forward or parallel approach to cook surface
control.
• As-Built Description:
• Proposed Solution:
4427
2011-12
ADAAG 16.7.4, 2.7.2, 4.2.4.1
CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Picnic Table
Project Year:

Funding source:

Project:
902.2
1 JOB $450 $450
26" high x 28" wide x 16" deep
PCODE NH11A Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
4426
2011-12
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $62,146.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4826, Packet Page 5031 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1004-0-1
Casanova Oak Knoll Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: 735 Ramona Avenue CIP - General Fund
Total Costs for Part: Exterior $62,146.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4827, Packet Page 5032 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
1 Overlook at Corner of Hoffman and Filmore
Fixed Bench
Project Year:

Funding source:

Project:
903.2
PCODE NO07 1 JOB $500 $500
Clear floor or ground space (30" x 48") not
overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
2337
2011-12
ADAAG 4.32.2
CSAS 1118B.4
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
206.1
PCODE EF13 120 LF $45 $5,400 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

Provide new 48" wide walk from street to bench
area and trash bin.
• As-Built Description:
• Proposed Solution:
2336
2011-12
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 POT from Cypress St. to Play Structure and Picnic Table Fixed Bench
Project Year:

Funding source:

Project:
903.2
REF
18" wide
PCODE NO07REF Clear floor or ground space (30" x 48") not overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
• As-Built:
2346
2011-12
ADAAG 16.12.4
CSAS 1132B.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Picnic Area
Project Year:

Funding source:

Project:

PCODE NH13AREF REF
Clear floor or ground space (30"x 48"), not
exceeding 1:50 (2%) slope is not provided at each
seating space required to be accessible. (Exception:
at special surface conditions 1:33 is allowed).

Provide clear floor or ground space 30"x 48".
• As-Built Description:
• Proposed Solution:
2347
2011-12
ADAAG 16.5.4
CSAS 1132B.1
Severity 2
Priority 2 General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4828, Packet Page 5033 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
Picnic Table
Project Year:

Funding source:

Project:
902.2
1 JOB $450 $450
26" high x 19" deep
PCODE NH11A Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Modify picnic table as required to provide knee
clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
2345
2011-12
ADAAG 16.5.4.

CSAS 1132B.1
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
206.1
PCODE EF13 320 LF $45 $14,400 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

Provide new 48" wide walk / sidewalk connecting
bench, picnic table and play structure.
• As-Built Description:
• Proposed Solution:
2344
2011-12
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 POT from Cypress St. to Tennis Court
Drinking Fountain
Project Year:

Funding source:

Project:
602.3
1 JOB $100 $100
7 lbs
PCODE IA03NT Fountain bubbler not easily activated by lever, push bar, or other accessible control.

Adjust to be less than 5 lbs.
• As-Built Description:
• Proposed Solution:
• As-Built:
2355
2011-12
ADAAG 4.15.4
CSAS 1115B.4.6.5
Severity 3
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE IA04 1 JOB $3,000 $3,000 CA only: Drinking fountain not located in an alcove (min. 32" wide x 18" deep) or otherwise encroaches
into pedestrian way.

Provide new alcove for drinking fountain, or, if
unreasonable hardship is determined, provide wing
walls or cane-detectable railings on each side of the
drinking fountain. The wings must project out from
the supporting wall at least as far as the drinking
fountain to within 6” of the surface of the
circulation path, but cannot reduce the required
clear width of the adjacent accessible route.
• As-Built Description:
• Proposed Solution:
2354
2011-12 1115B.4.6.3; Fig. 11B-3A
(b)
CSAS
Severity 2
Priority 5
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4829, Packet Page 5034 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
Walk
Project Year:

Funding source:

Project:
405.1
120 LF $260 $31,200

8.6% - 10.5%
PCODE EF01A Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Provide ramp with handrails on both (2) sides.
• As-Built Description:
• Proposed Solution:
• As-Built:
2352
2011-12
ADAAG 4.8.1
CSAS 1133B.7.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
403.3
REF

4.7% - 6.0%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2353
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
8 Stairs Connecting Tennis Court to Upper Play Area
Stairs
Project Year:

Funding source:

Project:
504.2
PCODE EC07ANT 35 LF $75 $2,625 Stone steps do not have uniform riser height due to uneven surfaces.

Remodel stairs as needed.
• As-Built Description:
• Proposed Solution:
2363
2011-12
CSAS 1133B.4.5.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
9 Stairs at South Side of Tennis Court
Stairs
Project Year:

Funding source:

Project:
504.2
30 LF $75 $2,250
8" - 10" risers
PCODE EC07ANT Stone steps do not have uniform riser height due to uneven surfaces.

Remodel stairs as needed.
• As-Built Description:
• Proposed Solution:
• As-Built:
2365
2011-12
CSAS 1133B.4.5.3
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $59,925.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4830, Packet Page 5035 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1005-0-1
Cypress Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Monterey, CA 93940 CIP - General Fund
Total Costs for Part: Exterior $59,925.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4831, Packet Page 5036 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1006-0-1
Deer Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Deer Forest Road CIP - General Fund
3 POT from Park Entrance at Mule Dear Way to Drinking Fountain Drinking Fountain
Project Year:

Funding source:

Project:

PCODE IA05C 1 JOB $500 $500
Drinking fountain lacks protection for visually
impaired persons.

Provide cane-detectable rails.
• As-Built Description:
• Proposed Solution:
2842
2011-12
ADAAG 4.4.1
CSAS 1115B.4.6.3
Severity 3
Priority 3 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
602.2
1 JOB $2,220 $2,220

3.6%
PCODE IA06NT 30" wide x 48" long clear floor space not provided at drinking fountain.

Provide clear floor space at drinking fountain.
• As-Built Description:
• Proposed Solution:
• As-Built:
2841
2011-12
ADAAG 4.15.5(1)*
CSAS 1115B.4.6.3
Severity 2
Priority 3
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Fixed Bench
Project Year:

Funding source:

Project:
903.2
1 JOB $500 $500
RS: 5.1%
CS: 4.1%
PCODE NO07NT Clear floor or ground space (30" x 48") not overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
• As-Built:
2844
2011-12
ADAAG 16.12.4
CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Signage
Project Year:

Funding source:

Project:
703.5.5
1 JOB $200 $200
44" from edge of walkway
PCODE SA02ANT Information on bulletin stand not readable because it is distanced from the walkway for viewing
purpose.

Install level concrete pad in front of bulletin stand
connecting with existing walkway.
• As-Built Description:
• Proposed Solution:
• As-Built:
2843
2011-12
ADAAG 4.30.3
CSAS 1117B.5.4
Severity 4
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 POT from Drinking Fountain to Play Structure
Play Structure
Project Year:

Funding source:

Project:
1008.4.1
8 SF $15 $120
48" wide
PCODE OC01A A 60" x 60" clear area is not provided on at least one side of the transfer platform.

Provide space as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
2845
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4832, Packet Page 5037 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1006-0-1
Deer Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Deer Forest Road CIP - General Fund
Project Year:

Funding source:

Project:

REF
Slope: 6.4%
PCODE OC01ANT A 60" x 60" clear area is not provided on at least one side of the transfer platform.

Provide space as required.
• As-Built Description:
• Proposed Solution:
• As-Built:
2846
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
1 JOB $125 $125
39"
PCODE OC01ENT At least one handhold, 25"-27" above the ground surface, needs to be provided -- or the transfer
platform needs an edge that can be gripped.

Provide handhold.
• As-Built Description:
• Proposed Solution:
• As-Built:
2847
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 2
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE OC04 1 JOB $225 $225
Grab bars are not provided where platform height
changes.

Provide grab bars.
• As-Built Description:
• Proposed Solution:
2848
2011-12
ADAAG 36 CFR Part 1191
CSAS DSA 99-02
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
5 POT from Play Structure to Basketball Court / Picnic Tables Picnic Area
Project Year:

Funding source:

Project:

PCODE NH02 20 LF $45 $900
Single fixed picnic table is not connected to an
outdoor recreation access route.

Provide connection to recreation access route.
• As-Built Description:
• Proposed Solution:
2852
2011-12
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:
902.2
1 JOB $850 $850
28" high x 29" wide x 14.5" deep
PCODE NH11B Knee clearance at minimums 27" high, 30" wide, and 19" deep is not provided.

Replace inaccessible picnic table with new
accessible, providing knee clearance.
• As-Built Description:
• Proposed Solution:
• As-Built:
2853
2011-12
ADAAG 4.32.3
CSAS 1122B.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Ramps
Project Year:

Funding source:

Project:
303.4
PCODE EB01A 280 SF $100 $28,000 Ramp needed to provide disabled access at steps or change of level along path of travel.

Provide new concrete ramp with handrails [slope
more than 1:20 (5.0%) needed].
• As-Built Description:
• Proposed Solution:
2851
2011-12
ADAAG 4.1.1
CSAS 1127B.1
Severity 3
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4833, Packet Page 5038 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1006-0-1
Deer Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Deer Forest Road CIP - General Fund
Slope
Project Year:

Funding source:

Project:
403.3
REF

2.1% - 3.1%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
2850
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 4
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
REF

6.3% - 14.2%
PCODE EF01REF Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
2849
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
6 Fixed Benches Adjacent to Sidewalk at Deer Forest Drive Fixed Bench
Project Year:

Funding source:

Project:
903.2
1 JOB $500 $500
RS: 7.8%
CS: 5.6%
PCODE NO07NT Clear floor or ground space (30" x 48") not overlapping with other clear space requirements, is
not provided at at least one end of the bench.

Provide and position clear floor or ground space to
allow wheelchair users to be seated shoulder-toshoulder with an individual seated on the bench. • As-Built Description:
• Proposed Solution:
• As-Built:
2854
2011-12
ADAAG 16.12.4
CSAS 1132B.1
Severity 2
Priority 2
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Total Costs for Floor: On-Site $34,140.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4834, Packet Page 5039 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1006-0-1
Deer Flats Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Deer Forest Road CIP - General Fund
Total Costs for Part: Exterior $34,140.00
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4835, Packet Page 5040 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1007-0-1
Don Dahvee Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont Street & Iris Canyon Road CIP - General Fund 1 Parking Area at Don Dahvee Lane
Detectable Warning
Project Year:

Funding source:

Project:

PCODE EG09 16 LF $27 $432
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.

Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area at street crossing.
• As-Built Description:
• Proposed Solution:
4011
2011-12
ADAAG 4.29.5
CSAS 1133B.8.5
Severity 3
Priority 1 General Fund
City ADA Transition Plan Upgrade
Picnic Area
Project Year:

Funding source:

Project:
1 JOB $850 $850
No knee space
PCODE NH01 Single fixed picnic table has no accessible seating space.

Provide accessible seating space at single fixed
picnic table near parking area.
• As-Built Description:
• Proposed Solution:
• As-Built:
4012
2011-12
ADAAG 4.1.2(2), 5.4
1124B.1, 1127B.1,
1132B.2
CSAS
Severity 2
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE NH02 80 LF $45 $3,600 Single fixed picnic table near parking area is not connected to an outdoor recreation access route.

Provide connection to recreation access route.
• As-Built Description:
• Proposed Solution:
4013
2011-12
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
2 Picnic Table Across Vio Robles
Picnic Area
Project Year:

Funding source:

Project:
1 JOB $850 $850
Knee space: 25" high
PCODE NH01 Single fixed picnic table has no accessible seating space.

Provide accessible seating space at single fixed
picnic table.
• As-Built Description:
• Proposed Solution:
• As-Built:
4015
2011-12
ADAAG 4.1.2(2), 5.4
1124B.1, 1127B.1,
1132B.2
CSAS
Severity 2
Priority 2 General Fund
City ADA Transition Plan Upgrade
Project Year:

Funding source:

Project:

PCODE NH02 25 LF $45 $1,125 Single fixed picnic table is not connected to an outdoor recreation access route.

Provide connection to recreation access route.
• As-Built Description:
• Proposed Solution:
4014
2011-12
ADAAG 16.5.1.1.

CSAS 1132B.1
Severity 3
Priority 2 General Fund
City ADA Transition Plan Upgrade
3 Ramp Leading to Sidewalk and Del Monte Mall Center
March 12, 2013 S a l l y S w a n s o n A r c h i t e c t s , I n c .

APPENDIX N
Council Regular Meeting, 12/17/2024, Item No. 17., Item Page 4836, Packet Page 5041 Codes / Mitigation Info Qty Unit Cost Total
Access Compliance Survey Report
Facility:
1007-0-1
Don Dahvee Park Part: Exterior Floor: On-Site
City of Monterey
Item No. and Name
Existing Architectural Barrier
and Proposed Solution
Address: Fremont Street & Iris Canyon Road CIP - General Fund Slope
Project Year:

Funding source:

Project:
403.3
REF

2.5% - 9.4%
PCODE EF07REF Cross slope more than 1/4":12" (2%).

Modify cross slope.
• As-Built Description:
• Proposed Solution:
• As-Built:
4017
2011-12
ADAAG 4.3.7
CSAS 1133B.7.1.3
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
Walk
Project Year:

Funding source:

Project:
403.3
1200 SF $25 $30,000

6.2% - 16.1%
PCODE EF01 Walk: Slope greater than 1:20 (5.0%), and walk does not comply with requirements for ramps.

Modify walk/sidewalk slope to 1:20 or less.
• As-Built Description:
• Proposed Solution:
• As-Built:
4016
2011-12
ADAAG 4.3.7
CSAS 1133B.7.3
Severity 2
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
4 Steep Section Under Mall Bridge
Accessible Route
Project Year:

Funding source:

Project:
206.1
PCODE EF13 100 LF $45 $4,500 No walk / sidewalk provided to connect accessible facilities or elements that are on the same site.

South side of bridge; provide sidewalk connecting
to mall entry and sidewalk on other side of bridge.
• As-Built Description:
• Proposed Solution:
4019
2011-12
ADAAG 4.3.2
CSAS 1114B.1.2
Severity 3
Priority 1
ADA-2010
General Fund
City ADA Transition Plan Upgrade
5 Trail and Bridge Leading to Mall Near Soledad
Curb Ramp
Project Year:

Funding source:

Project:
406.1
PCODE EH01REF REF
No curb ramp available where an accessible route
crosses a curb.