AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 63626
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
CONTROL POINT SET THIS SURVEY
FOUND MONUMENT AS NOTED
FOUND MONUMENT WELL
DIMENSION POINT, NOTHING FOUND OR SET
SUBJECT PARCEL(S) PROPERTY LINE
EXISTING PROPERTY/RW LINE
EXISTING EASEMENT LINE
WOOD FENCE
WIRE/BARBED WIRE FENCE
WROUGHT IRON FENCE
EXISTING WATER LINE AND SIZE
WATER BLOWOFF VALVE
WATER VALVE
FIRE HYDRANT
EXISTING DRAIN LINE SIZE & FLOW DIRECTION
DRAIN MANHOLE
DRAIN INLET OR CATCH BASIN
EXISTING SEWER LINE SIZE & FLOW DIRECTION
SEWER MANHOLE
SEWER CLEANOUT
STREET LIGHT
UTILITY PULLBOX
UTILITY/JOINT POLE
SIGN
BORING LOCATION
CONCRETE SURFACE
ASPHALT SURFACE
LEGEND:
Exp.12-31-2022
ET
V
TS
A
EK
IA
R
f A
o C L I FO
N
Y
NE
NO.5914
IN A
E E
H
L I CENSED LAND SURVEYOR
THE HORIZONTAL DATUM FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, NAD83, ZONE II AND IS BASED UPON GPS OBSERVATIONS TO NGS STATIONS "NEWFIDDY" (PID DL9185) AND "HPGN CA 03 09" (PID JS4669)
THE VERTICAL DATUM FOR THIS SURVEY IS NAVD88 AND IS BASED UPON CITY OF ROSEVILLE BENCHMARKS BM-10 (3 1/4” BRASS DISK STAMPED 2018 PLS 8278 AT WEST OF D.I. AT SOUTHEAST CORNER OF CIRBY WAY AND SUNRISE BLVD, ELEV. 158.13) AND BM-96 (3 1/4" BRASS DISK STAMPED PLS 8278, AT TOP OF THE CURB 1 FOOT SOUTH OF D.I. AT THE SOUTHWEST CORNER OF THE INTERSECTION OF BLUE OAKS BLVD. AND WOODCREEK OAKS BLVD., ELEV. 114.97)
HORIZONTAL/VERTICAL DATUM
THE PROPERTY LINES FOR THE SUBJECT PARCEL ARE BASED ON THE LARGE LOT FINAL MAP OF "CAMPUS OAKS" FILED IN BOOK "DD" OF MAPS, PAGE 47. ADJACENT PROPERTY LINES SHOWN HEREON WERE TAKEN FROM THE CITY OF ROSEVILLE G.I.S. SHAPEFILE ON JUNE 10, 2020 AND ADJUSTED TO FIT THE MONUMENTATION FOUND IN THE COURSE OF THIS SURVEY.
PROPERTY LINE INFORMATION
APN 496-030-008-000
EXISTING MONITORING WELL
PROPOSED ASR WELL
30" TREE
10" TREE
36" TREE
6" TREE
8" TREE
6" OAK
20" TREE
8" TREE
6" TREE
10" TREE
24" OAK
36" OAK
48" 0AK
SET 5/8" REBAR WITH CAP
N. 2043588.864
E. 6755857.263
ELEV.=134.65
SET 5/8" REBAR WITH CAP
N. 2043520.796
E. 6756192.466
ELEV.=129.70
STORM DRAIN MANHOLE
RIM EL. = 131.86
FL 12" RCP NW = 125.21
FL 18" RCP SE = 125.26
FL 18" RCP NE = 125.11
ELEC. PB
2.5' WOOD POST & CABLE FENCE
P L E A S A N T
G R O V E
B L V D .
6' WROUGHT IRON FENCE
FL 18" RCP SW = 125.11
FL 12" RCP SE = 128.06
DI GRATE EL.= 131.21
8" BLOCK WALL
"NO PARKING"
ELEC. PB
P L E A
L A P O R T E D R I V E
30" TREE
10" TREE
36" TREE 6" TREE
8" TREE
6" OAK
20" TREE
8" TREE
6" TREE
10" TREE
24" OAK
36" OAK
48" 0AK
36" OAK
8" OAK
36" OAK
24" OAK
30" OAK
24" OAK
120
120
125
125
130
125
125
130
130
130
130
135
135
135
135
130
130
PROJECT NO. LAST SAVED BY:FILE NAME: Plot Date:
MED
HPG
DM
19G06
7 GENERAL
MISTY WOOD ASR WELL
SURVEY CONTROL DATA
11843A1019G006.dwg
hgarcia 12/13/2024 5:48:41 PM
0 10' 20' 40'
SCALE: 1" = 20'
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
CONTROL POINT SET THIS SURVEY
FOUND MONUMENT AS NOTED
FOUND MONUMENT WELL
DIMENSION POINT, NOTHING FOUND OR SET
SUBJECT PARCEL(S) PROPERTY LINE
EXISTING PROPERTY/RW LINE
EXISTING EASEMENT LINE
WOOD FENCE
WIRE/BARBED WIRE FENCE
WROUGHT IRON FENCE
EXISTING WATER LINE AND SIZE
WATER BLOWOFF VALVE
WATER VALVE
FIRE HYDRANT
EXISTING DRAIN LINE SIZE & FLOW DIRECTION
DRAIN MANHOLE
DRAIN INLET OR CATCH BASIN
EXISTING SEWER LINE SIZE & FLOW DIRECTION
SEWER MANHOLE
SEWER CLEANOUT
STREET LIGHT
UTILITY PULLBOX
UTILITY/JOINT POLE
SIGN
BORING LOCATION
CONCRETE SURFACE
ASPHALT SURFACE
LEGEND:
Exp.12-31-2022
ET
V
TS
A
EK
IA
R
f A
o C L I FO
N
Y
NE
NO.5914
IN A
E E
H
L I CENSED LAND SURVEYOR
APN 496-030-008-000
HORIZONTAL/VERTICAL DATUM
PROPERTY LINE INFORMATION
THE HORIZONTAL DATUM FOR THIS SURVEY IS THE CALIFORNIA COORDINATE SYSTEM, NAD83, ZONE II AND IS BASED UPON GPS OBSERVATIONS TO NGS STATIONS "NEWFIDDY" (PID DL9185) AND "HPGN CA 03 09" (PID JS4669)
THE VERTICAL DATUM FOR THIS SURVEY IS NAVD88 AND IS BASED UPON CITY OF ROSEVILLE BENCHMARKS BM-10 (3 1/4” BRASS DISK STAMPED 2018 PLS 8278 AT WEST OF D.I. AT SOUTHEAST CORNER OF CIRBY WAY AND SUNRISE BLVD, ELEV. 158.13) AND BM-96 (3 1/4” BRASS DISK STAMPED 2018 PLS 8278, AT TOP OF CURB 1 FOOT SOUTH OF D.I. AT THE SOUTHWEST CORNER OF THE INTERSECTION OF BLUE OAKS BLVD. AND WOODCREEK OAKS BLVD., ELEV. 114.97)
THE PROPERTY LINES SHOWN HEREON WERE TAKEN FROM THE CITY OF ROSEVILLE G.I.S.
SHAPEFILE ON JUNE 10, 2020 AND ADJUSTED TO FIT THE CENTERLINE MONUMENTATION FOUND IN THE COURSE OF THIS SURVEY.
EXISTING MONITORING WELL
EXISTING ASR WELL
Plot Date: 12/11/2024 5:47:10 PM PROJECT NO. LAST SAVED BY: FILE NAME: CECECE 00GC01 12 CIVIL GENERAL CIVIL NOTES AND LEGEND 11843A1000GC001.dwg hgarcia NOTES GENERAL PIPELINE NOTES: 1. DIMENSIONS TO STRUCTURES, REFERENCED PIPING, PAVING, AND OTHER IMPROVEMENTS IS APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS 14 DAYS IN ADVANCE OF THE CONSTRUCTION PROGRESS. THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER. 2. CONTRACTOR SHALL MAINTAIN A MINIMUM CLEARANCE OF 10 FEET HORIZONTAL AND 3 FEET VERTICAL BETWEEN THE SEWER LINES AND EXISTING WATER LINES. 3. REFER TO THE GEOTECHNICAL REPORT LOCATED IN THE APPENDIX OF THE SPECIFICATIONS FOR ADDITIONAL INFORMATION ON THE GEOTECHNICAL CONDITIONS AND BORING INFORMATION. 4. IN ALL LOCATIONS WHERE TRENCH PLATE IS USED FOR VEHICULAR OR PEDESTRIAN TRAFFIC, THE CONTRACTOR SHALL APPLY SKID RESISTANT COATING ON THE TRENCH PLATES AND COLD MIX ASPHALT CONCRETE AT THE EDGES. THE TRENCH PLATES SHALL BE NOTCHED INTO THE ASPHALT, CONCRETE, OR TRAVELED SURFACE TO PREVENT SLIPPAGE AND ROCKING UNDER TRAFFIC. 5. THE CONTRACTOR SHALL MAINTAIN ACCESS TO ALL PROPERTIES ADJACENT TO THE WORK, THROUGHOUT THE CONSTRUCTION PERIOD. 6. ALL OPEN TRENCHES, WORK AREAS AND SHAFTS SHALL HAVE A SHORING SYSTEM IN ACCORDANCE WITH OSHA, STATE AND LOCAL REQUIREMENTS. 7. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, COUNTY, AND LOCAL LAWS AND ORDINANCES RELATING TO THE SAFETY AND CHARACTER OF WORK, EQUIPMENT AND PERSONNEL. THIS INCLUDES BUT IS NOT LIMITED TO SHEETING, SHORING, BRACING, VENTILATION, CONFORMANCE WITH TRAFFIC CONTROL AND MAINTENANCE OF BARRICADES AND WARNING DEVICES. 8. LAYOUT DRAWINGS ARE REQUIRED FOR PIPING INSTALLED. 9. CONTRACTOR SHALL TAKE ALL PRACTICAL PRECAUTIONS TO MINIMIZE DISTURBANCES TO STREAMS, VEGETATION, TREES AND CROP LANDS. WHEREVER PRACTICAL LEAVE EXISTING TREES AND VEGETATED AREAS UNDISTURBED. UTILITY NOTES: EARTHWORK NOTES: 1. CLEAR THE CONSTRUCTION AREA OF NATURAL OBSTRUCTIONS EXISTING FOUNDATIONS, BUILDINGS, FENCES, LUMBER, WALLS, STUMPS, BRUSH, WEEDS, RUBBISH, TREES, BOULDERS, AND ANY OTHER ITEMS WHICH INTERFERES WITH CONSTRUCTION OPERATIONS OR ARE DESIGNATED FOR REMOVAL. 2. GRUB OUT AND DISPOSE OF TREE TRUNKS AND ROOT MATERIAL BELOW THE GROUND SURFACE REMAINING AFTER CLEARING. 3. DISPOSE OF THE UNACCEPTABLE BACKFILL MATERIAL FROM THE CLEARING AND GRUBBING OPERATIONS AT NO ADDITIONAL COST TO THE OWNER. 4. STRIP AND STOCKPILE THE TOPSOIL. THE DEPTH OF STRIPPING SHALL BE ESTIMATED TO BE 12-INCHES BUT WILL BE DETERMINED IN THE FIELD AS SOIL CONDITIONS DICTATE. 5. REPLACE STOCKPILED SOIL AND RESTORE SITE AS SPECIFIED. 6. ROCK AND AGGREGATE STORAGE AREAS SHALL BE RESTORED BY EXCAVATING ANY SOILS CONTAINING ROCK OR AGGREGATE AND BACKFILLING WITH TOPSOIL. SOIL REMOVED MAY BE USED FOR TRENCH BACKFILL ABOVE THE PIPE ZONE AND 3 FEET BELOW FINISHED GRADE. 1. EXISTING UTILITIES IN THE PROJECT MAY BE IN A FRAGILE CONDITION. THE CONTRACTOR SHALL EXERCISE NECESSARY CAUTION WHEN WORKING NEAR EXISTING UTILITIES. 2. PLAN LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES ARE BASED ON RECORD DRAWINGS, POTHOLING AND SURVEY INFORMATION AND ARE CONSIDERED APPROXIMATE ONLY. WHERE NO ELEVATIONS ARE SHOWN, NO INFORMATION WAS AVAILABLE DURING THE DESIGN PERIOD. 3. SOME UTILITY SERVICES MAY NOT BE SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL TAKE NECESSARY MEASURES TO LOCATE AND PROTECT SERVICE DURING CONSTRUCTION. 4. CONTRACTOR SHALL CALL THE LOCAL UTILITY LOCATOR PRIOR TO ANY EXCAVATION ACTIVITIES. 5. NOTIFY THE CITY OF ROSEVILLE UNDERGROUND SERVICE ALERT (U.S.A.) ONE-CALL SYSTEM. THE CONTRACTOR SHALL NOTIFY THE U.S.A. CENTER 48 HOURS IN ADVANCE OF PERFORMING ANY EXCAVATION WORK BY CALLING 1-800-227-2600. 6. THE LOCATION, SIZE, AND MATERIALS OF EXISTING UNDERGROUND UTILITIES SHOWN ON THESE DRAWINGS ARE APPROXIMATE AND IS SHOWN FOR BIDDING PURPOSES. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTACT THE UTILITY OWNERS SO THAT THOSE UTILITIES MAY MARK THE LOCATION OF THEIR UTILITIES PRIOR TO ANY EXCAVATION ACTIVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE AND PROTECT EXISTING UTILITIES. X X X SYMBOLS SYMBOL DESCRIPTION FLOW/SLOPE DIRECTION MANHOLE (PROFILE) MANHOLE (PLAN) PULL BOX POWER TOWER SYMBOL DESCRIPTION ROCK WALL BURIED VALVE HEADWALL CABLE TV UTILITY POLE UTILITY POLE GUY WIRE PIPE CAP OR CONNECTION CHECK VALVE FLANGE PLUG VALVE REDUCER GUARD POST PCTVPH SHRUB/HEDGE TREE T TELEPHONE PEDESTAL CO CLEANOUT AIR RELEASE VALVE BLOW OFF VALVE LIGHT PP POWER POLE SIGN/SIGN POST ELECTRICAL MANHOLE AND PULL BOX SERVICE CONNECTION GATE LINE WORK PHXX HOSE BIBB / YARD HYDRANT FIRE HYDRANT CATCH BASIN E POTHOLE POTHOLE NUMBER BALL VALVE GATE VALVE HATCH PATTERNS M METER BOX BUTTERFLY VALVE NOTE: ALL SYMBOLS SHOWN AS NEW. EXISTING SYMBOLS ARE SCREENED. COORDINATES / ELEVATION ROADWAY / PIPE CURVES COORDINATES SLOPE CALLOUT CONTROL POINT 2 1 X 1325.00 PT RADIUS ANGLE CLOCKWISE PC EDGE OF PVMT OR OUTSIDE FACE OF CURB CXX SPOT ELEVATION FG XX.XX EXISTING SPOT ELEVATION 2:1 N=XXXXXX.XX E=XXXXXX.XX N=1600000 E=1000000 2.0% TC XX.XX (REFER TO ABBREVIATIONS FOR DESIGNATION) S=0.0020 ROADWAY / PIPE CURVE (SEE TABLE ON EACH PAVING AND GRADING OR CIVIL PIPING DWG WITH ROADWAY / PIPE CURVES.) LENGTH CURVE NUMBER RADIUS POINT XX XX SHORING /\ FLOWLINE GUARDRAIL NEW ROAD EXISTING CONTOURS (SCREENED) NEW FENCE POWER POLE & LINE EXISTING FENCE (SCREENED) EXISTING ROAD (SCREENED) PROPERTY LINE OR RIGHT OF WAY REMOVE OR ABANDONED (CROSS HATCHING: FENCE SHOWN AS EXAMPLE) SLOPE EXISTING PIPING (TRIPLE LINES) (SCREENED) NEW PIPING (SINGLE LINE) NEW PIPING (TRIPLE LINES) EXISTING STRUCTURES (SCREENED) EXISTING PIPING (SINGLE LINE)(SCREENED) CENTER, MONUMENT, OR SURVEY LINE PP X X X X X X OHE OHE CABLE TV (UNDERGROUND) CTV CTV FIBER OPTIC NATURAL GAS G G SANITARY SEWER STORM DRAIN 310 310 NEW STRUCTURES OR EDGE OF PAVEMENT FUTURE ROAD, WATER EDGE OR RIDGE HIDDEN LINE OR TRAIL EDGE FO FO UNDERGROUND ELECTRIC RAILROAD TRACKS FUEL TELEPHONE WATER NEW CONTOURS SILT FENCE SF SF EASEMENT EXISTING EASEMENT CITY LIMITS EXISTING GRADE (PROFILE) PROPOSED GRADE (PROFILE) CURB CURB & GUTTER SWALE LOC LOC UGE UGE F F SS SS SD SD TEL TEL W W FORCEMAIN SANITARY SEWER FM FM STAGING AREA CLSM TREAD PLATE AGGREGATE BASE COURSE (ABC) ASPHALT PAVING GRATING BEDROCK CONCRETE (ALL CLASSES) DRAIN ROCK GRAVEL RIPRAP EXISTING/ UNDISTURBED SOIL STRUCTURAL FILL OR BACKFILL STEEL LANDSCAPING LIMITS OF CONSTRUCTION OR CONTROL POINT SOIL BORING LOCATIONS B-XX XX EXISTING MONUMENT EXISTING CONTROL POINT (WITH AERIAL) SPAN MATCH LINE MATCH LINE STA XXX SEE DWG XXX No. 63626 REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION STAGING AREAS: 1. THE CITY SHALL PROVIDE STAGING AREAS ON AND/OR NEAR TO THE SITES FOR THE TEMPORARY STORAGE OF MATERIALS AND EQUIPMENT. THE CITY IS NOT RESPONSIBLE FOR SECURITY AND THEFT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PUBLIC SAFETY. REFER TO TECHNICAL SPECIFICATIONS. CATHODIC PROTECTION TEST STATION CPTS 129
129
131
130
129
130
CB-3A
FG 130.20
FG 130.40
FG 130.40
CB-1A
FG 130.30
CB-1B
FG 130.30
CB-1C
FG 130.20
FG 130.85
CB-2
FG 130.10
FG 131.00
HP 130.75
FG 130.85
FG 130.80
FG 130.60
HP 130.90
FG 130.60
FG 130.50
FG 130.47
FG 130.85
HP 130.60
FG 130.70
FG 130.40
CB-3
FG 130.20 FG 130.70
CB-3B
FG 130.05
FG 130.60
130.60
130.60
31 32
33 34
FG 130.80
FG 130.60
FG 130.85
SSMH
FG 130.50
129
129
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
0 10' 20' 40'
SCALE: 1" = 20'
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
13C01
13 CIVIL
CAMPUS OAKS
PAVING, GRADING, AND SITE PLAN
11843A1013C001.dwg
hgarcia
usanorth811.org
WELL
BUILDING
10 1
9 TYP
CR110
TYP
CR110
GENERAL NOTES:
1. THE PLANS HAVE BEEN PREPARED IN PART
BASED ON AVAILABLE RECORD INFORMATION.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL EXISTING CONDITIONS PRIOR TO BEGINNING
THE WORK.
2. SURFACE RESTORATION REQUIRED AT
TRENCHES AND EXCAVATION IS NOT SHOWN ON
THESE PLANS.
3. SEE DETAIL 2/13C05 FOR TYPICAL PAVEMENT
SECTION.
X KEY NOTES:
1. FUTURE WATER TREATMENT FILTER VESSELS, IF
REQUIRED. NOT PART OF THIS CONTRACT.
2. FUTURE FILTER BACKWASH TANK AND SEWER
AIR-GAP, IF REQUIRED. NOT PART OF THIS
CONTRACT.
3. ELECTRICAL TRANSFORMER, SEE 13E01.
4. 2" BACKFLOW PREVENTER INSTALL SIMILAR TO
CITY OF ROSEVILLE STANDARD DETAIL W-7.
5. FIBER OPTIC HANDHOLE, SEE 13E01.
6. AUTOMATIC GATE OPENER PER SECTION 02820.
7. AUTOMATIC ROLLING GATE PER SECTION 02820.
8. GATE KEY PAD PER SECTION 02820.
9. AIR-GAP STRUCTURE TO STORM DRAIN. SEE
DETAIL 1/13C05 FOR DETAILS.
10. EXISTING MONITORING WELL.
11. CMU WALL (REFER TO 13C04 FOR COORDINATE
POINTS).
12. PAVED DRIVE. REMOVE AND REPLACE CURB AND
GUTTER TO MEET CITY STANDARD DETAIL ST-21.
INSTALL DETACHED SIDEWALK PER CITY DETAIL
ST-7.
13. FUTURE LOCATION FOR FIRE PROTECTION
BACKFLOW AND FDC ASSEMBLY PER CITY OF
ROSEVILLE STANDARD DETAIL W-2.
14. FLOW METER INSTALL SIMILAR TO CITY OF
ROSEVILLE STANDARD DETAIL W-7.
15. CONDENSING UNIT, SEE MECHANICAL DRAWINGS.
16. CONCRETE LANDING, SLOPED AT 1/4" PER FOOT
AWAY FROM THE BUILDING FOR DRAINAGE PER
CR306/TYP.
17. PEDESTRIAN ACCESS GATE.
18. INSTALL 20 FT WIDE IRRIGATED LANDSCAPED
STRIP WITH CITY APPROVED SHRUBS AND
GROUND COVER.
19. IRRIGATION CONTROL PANEL AND CONDUIT.
POST MOUNT OR SURFACE MOUNT ON
PERIMETER WALL.
20. EXISTING FIRE HYDRANT.
21. EXISTING STREET LIGHT.
22. INSTALL TYPE 2 VERTICAL CURB AND GUTTER
PER CITY OF ROSEVILLE STANDARD DETAIL ST-17.
START AND STOP AT EXISTING SCORE MARKS OR
JOINTS. REMOVE AND REPLACE BARRICADES AS
REQUIRED.
23. INSTALL TYPE D DRIVEWAY APRON PER CITY OF
ROSEVILLE STANDARD DETAIL ST-21.
24. ELECTRICAL PULL BOX, SEE 13E01.
25. EXISTING FIBER OPTIC STUB UP AND ELECTRICAL
UTILITY VAULT. CONTRACTOR TO DEMOLISH AND
ROUTE NEW FO CABLE AND ELEC CONDUIT TO
THE NEW FIBER OPTIC HANDHOLE AND
TRANSFORMER. SEE ELECTRICAL DRAWINGS..
26. STORM DRAIN MANHOLE PER CITY OF ROSEVILLE
STANDARD DETAIL DR-4 WITH DETAIL DR-8 GRATE
COVER.
27. POLE FOR LICENSE PLATE READER CAMERAS,
SEE ELECTRICAL DRAWINGS.
2 TYP
CS202
TOC 130.9
R
13M12
16 15
16 20
21 PAINTED DESERT DRIVE
NEW MEADOW DRIVE (FUTURE)
1 13C01
SCALE:
FILE:
1 DETAIL
- 1" =10'-0"
11843A1013C001
20' ROLLING GATE
6 5
3 11
12 14
13 4
7 17
PAINTED DESERT DRIVE
8 19
TYP
CF200
14 4
23 22 10' 20'
26 24
27 5
5' WIDE SIDEWALK
PER CITY STANDARDS
27 5' 3'
3 25
25 18
EX EP
EX CURB
EX BARRICADE
2 FO FO FO FO
UGE UGE UGE UGE FO UGE
GAS
VAULT
APPROX. LOCATION
GAS
SERVICE
20' P.G.& E. EASEMENT
PER 99-0026799
SD SD
SD
SS
SS SS SS SS
W
W
66 65 68
69 71
62 8" SD
SDMH-1
63 64
8" SD
12" SD
12" SD
4" SS
EX-EX-18" SD
18" SD
12" SD
EX-8" RW
EX-8" RW
EX-10" SS
EX-16" W
EX-10" SS
EX-10" SS
W W
W
56 59
55 58
52 53 51
W
61 45
44 43
73 8" SS
8" SD
EX-16" W
41 46
48 47
54 57
35 36 FO
42 UGE
UGE
FO
W SS
EX MONITORING WELL
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
GENERAL NOTES:
1. SEE GENERAL NOTES ON SHEET 00G04 AND CIVIL
NOTES ON 00GC01.
2. OFFSITE UTILITIES EXTENDED TO SITE BY
OTHERS. CONNECT TO SERVICES PROVIDED IN
FIELD.
3. REFER TO PIPE PROFILES FOR INVERT
ELEVATIONS NOT CALLED OUT ON THE PLANS.
MAINTAIN MINIMUM 36" COVER WHERE ANY
INVERT ELEVATION IS NOT IDENTIFIED.
4. PIPE TRENCHING AND SURFACE RESTORATION
SHALL BE PER THE CITY OF ROSEVILLE
STANDARD DETAILS AND CY111/TYP.
5. THE CONTRACTOR SHALL RESTORE ALL
LANDSCAPING AND IRRIGATION COMPONENTS
PER THE CITY OF ROSEVILLE STANDARDS WHERE
DISTURBED AS A RESULT OF THIS WORK. PLANTS
SHALL BE REPLACED IN KIND AND SIZE BY THE
CONTRACTOR.
6. REFER TO DRAWING 00GM05 FOR PIPE SCHEDULE
AND SECTION 15052 FOR GENERAL PIPING
REQUIREMENTS.
7. THESE PLANS HAVE BEEN PREPARED IN PART
BASED ON AVAILABLE RECORD INFORMATION.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL EXISTING CONDITIONS PRIOR TO BEGINNING
OF THE WORK.
8. EXISTING INVERT ELEVATIONS ARE BASED ON
AVAILABLE RECORD INFORMATION. CONTRACTOR
SHALL FIELD VERIFY INVERT ELEVATIONS PRIOR
TO BEGINNING THE WORK.
9. SEE DWG 13C06 FOR COORDINATE POINTS.
10. BURIED DI PIPE SHALL BE PROTECTED WITH A
CATHODIC PROTECTION SYSTEM OR WAX TAPE
PER SPECIFICATION 15320. ANODE AND TEST
STATION SPACING/PLACEMENT ARE
APPROXIMATE BASED ON OBSTACLES IN AREA
AND MAY BE MOVED. ALL ISOLATION FLANGES
MUST HAVE ISOLATION JOINT FLANGE KIT TEST
STATION INSTALLED AT THE LOCATION. ISOLATE
ALL DISSIMILAR PIPE, VALVES, ETC. ADD JOINT
BONDING TO DIP, REFER TO CP150 FOR JOINT
BOND DETAILS.
X
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
13C02
14 CIVIL
CAMPUS OAKS
YARD PIPING AND UTILITIES PLAN
11843A1013C002.dwg
hgarcia 12/13/2024 6:51:26 PM Plot Date:
KEY NOTES:
1. NOT USED
2. PROVIDE HAND HOLE PER ROSEVILLE ELECTRIC
REQUIREMENTS.
3. STORM DRAIN MANHOLE PER CITY OF ROSEVILLE
STANDARD DETAIL DR-4 WITH DETAIL DR-8 GRATE
COVER.
4. STUB OUT FOR FUTURE CONNECTION.
5. PROVIDE 4" DIP WITH BLIND FLANGE AND BLOW
OFF 24" ABOVE FINISHED GRADE. TYPICAL OF
THREE LOCATIONS.
6. ROUTE EACH 1" SAMPLE LINE FROM EXISTING
MONITORING WELL TO INSIDE THE BUILDING
(TWO TOTAL). ROUTE SAMPLE LINE TO AVOID
OTHER UTILITIES. WORK INCLUDES ALL FITTINGS,
WALL PENETRATIONS, AT-GRADE HANDHOLES,
AND PIPE SUPPORTS AS REQUIRED.
7. ROUTE EACH 1" SAMPLE LINE FROM EXISTING
MONITORING WELL TO THE SD AIR GAP
STRUCTURE (TWO TOTAL). ROUTE SAMPLE LINE
TO AVOID OTHER UTILITIES, WORK INCLUDES ALL
FITTINGS, WALL PENETRATIONS AT-GRADE
HANDHOLES, AND PIPE SUPPORTS AS REQUIRED.
8. NOT USED.
9. CONNECT TO EXISTING 18" STORM DRAIN STUB
OUT.
10. EXISTING 16" STUB UP. INSTALL BUTTERFLY
ISOLATION VALVE AND 4" BLOW OFF SIMILAR TO
TYP/CY733.
11. BACKFLOW PREVENTER, FLOW METER AND CORP
STOP PER CITY OF ROSEVILLE STANDARD DETAIL
W-7.
12. CONTRACTOR TO DEMOLISH EXISTING SEWER
LATERAL PIPE AND ROUTE NEW SEWER PIPE
FROM EXISTING SSMH-0 TO THE FACILITY.
13. CONTRACTOR TO DEMOLISH EXISTING FIBER
OPTIC STUB UP AND ELECTRICAL UTILITY VAULT
AND ROUTE NEW FO CABLE AND ELEC CONDUIT
TO THE NEW FIBER OPTIC HANDHOLE AND
TRANSFORMER. SEE ELECTRICAL DRAWINGS.
0 10' 20' 40'
SCALE: 1" = 20'
usanorth811.org
FUTURE WATER
TREATMENT FILTER TANKS
FUTURE FILTER BACKWASH
TANK WELL BUILDING
TYP
CS110 FUTURE SS AIR GAP
STRUCTURE TO SEWER
3 1
12" FI 4
12" FE 4
5 10" AF
4" GV
4" FPW
2" PW
16" PW
1" SAM
TYP
CS202
7 1" SAM
6 9
CONDENSING UNIT
(TWO EACH)
(TWO EACH)
PIPE
STUB
PAINTED DESERT DRIVE
NEW MEADOW DRIVE (FUTURE)
ELEC TRANSFORMER
FIBER OPT TIE-IN
TYP
CY716
5 FUTURE 4" BACKFLOW PREVENTER
2" BACKFLOW PREVENTER
FLOWMETER
11 CO
CONTRACTOR TO
CONFIRM POC
ELEVATION FOR TIE-IN
13 2
SCALE:
FILE:
1 DETAIL
- 1" =10'-0"
11843A1013C002
TYP
CP311
TYP
CP311
1 13C02
TYP
CP311
(TRAFFIC RATED)
TYP
CP311
(ABOVE GROUND)
(TRAFFIC RATED)
(TRAFFIC RATED)
2" RW
2" BACKFLOW
PREVENTER
11 CONTRACTOR TO POTHOLE
AND CONFIRM ELEVATION OF
EXISTING SEWER LATERAL
12 13M12
2 1
13M12
11 EXISTING
IRRIGATION VAULT
13 EXISTING FIBER
OPTIC STUB-UP
EXISTING
ELECTRICAL VAULT
13 13
CONTRACTOR
TO CONFIRM
POC FOR TIE-IN
13 13
CB-3 CB-3B
CB-3A
CB-2
CPTS
CPTS
CPTS
CB-1
CB-1A
CB-1C
16" BFV, TEE, 4" GV W/ BO 10
SD AIR-GAP STRUCTURE
SSMH-0
RW R
100
104
108
112
116
120
124
128
132
136
140
100
104
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 12+00
S=1.22%
S=1.19% CB-1 STA 10+56.93 RIM 130.30 INV IN 122.15 (12" W) INV IN 122.50 (8" E) INV IN 122.15 (12" S) INV OUT 121.95 (18" N) CB-2 STA 11+07.08 RIM 130.10 INV IN 122.93 (12" S) INV OUT 122.76 (12" N) CB-3 STA 11+55.32 RIM 130.20 INV IN 123.71 (8" E) INV IN 123.71 (8" W)INV OUT 123.51 (12" N) EX-10" SS INV 107.4± EX-8" RW INV=125.7± 4" SS INV 125.1± SDMH-1 STA 10+00 RIM 128.83 INV IN 121.63 (18" S) INV OUT 107.92 (18" W) S=0.69%
18" SD
12" SD 12" SD
S=0.47%
EX-18" SD
(2) 2" RW INV 127.0± 10" AF INV=124.1± 1" SAM INV 127.5± 108
112
116
120
124
128
132
136
140
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 11+20 SD AIR-GAP STRUCTURE STA 10+07.58 RIM 130.41 INV OUT 122.64 (12" E) INV OUT 122.74 (12" W) CB-1 STA 10+38.91 RIM 130.30 INV IN 122.15 (12" W) INV IN 122.50 (8" E) INV IN 122.15 (12" S) INV OUT 121.95 (18" N) CB-1C STA 10+91.39 RIM 130.20 INV OUT 123.02 (8" W) S=1.56%
S=1.00%
12" SD
8" SD 8" SS INV 124.6±2" PW INV=127.7± 4" FPW INV=124.9± CB-1A STA 10+00 RIM 130.30 INV IN 122.84 (12" E) S=-1.32%
12" SD 16" PW INV 120.4± UGE/FO INV 126.5±
108
112
116
120
124
128
132
136
140
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 11+20 CB-3A STA 10+00 RIM 130.20 INV OUT 124.20 (8" E) CB-3 STA 10+45.77 RIM 130.20 INV IN 123.71 (8" E) INV IN 123.71 (8" W) INV OUT 123.51 (12" N) CB-3B STA 10+95.98 RIM 130.05 INV OUT 124.27 (8" W) S=1.07% S=1.12%
8" SD 8" SD
104
108
112
116
120
124
128
132
136
140
104
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 11+20
S=2.00% SSMH-1 STA 10+68.88 RIM 130.50 INV IN 124.97 (4" E) INV OUT 124.77 (8" NW) 4" SS 12" SD INV 122.4± 12" SD INV 122.2±
8" SS
S=2.00% STA 10+00 EL 129.48 SSMH-0 STA 10+00 RIM 129.48 INV IN 107.20 (10" E) INV IN 120.00 (8" S) INV OUT 107.20 (10" W) STA 10+16.84 EL 124.58 2" PW INV=127.7± PROJECT NO. LAST SAVED BY:FILE NAME: Plot Date:
MED
HPG
DM
13C03
15 CIVIL
CAMPUS OAKS
PIPE PROFILES
11843A1013C003.dwg
hgarcia 9/12/2022 7:29:07 AM
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1013C003
1"=20'
1"=5'
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROPOSED GRADE
EXISTING GRADE
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1013C003
1"=20'
1"=5'
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1013C003
1"=20'
1"=5'
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1013C003
1"=20'
1"=5'
PROPOSED GRADE
EXISTING GRADE
PROPOSED GRADE
EXISTING GRADE
PROPOSED GRADE
EXISTING GRADE
GENERAL NOTES:
1. SEE GENERAL NOTES ON SHEET 00G04 AND CIVIL
NOTES ON 00GC01.
2. OFFSITE UTILITIES EXTENDED TO SITE BY
OTHERS. CONNECT TO SERVICES PROVIDED IN
FIELD.
3. EXISTING INVERT ELEVATIONS ARE BASED ON
AVAILABLE RECORD INFORMATION. CONTRACTOR
SHALL FIELD VERIFY INVERT ELEVATIONS PRIOR
TO BEGINNING THE WORK.
CLEANOUT
CONTRACTOR TO POTHOLE AND CONFIRM
ELEVATION OF EXISTING SEWER LATERAL
1 2
3 4
COORDINATE CONTROL POINTS
POINT
1 2
3 4
5 6
7 8
NORTHING
2050895.31
2050895.31
2050780.60
2050781.48
2050895.31
2050895.31
2050895.31
2050895.31
EASTING
6754930.02
6754888.84
6754886.65
6754998.78
6754997.95
6754950.02
6754957.35
6754952.02
DESCRIPTION
BEGIN WALL
WALL CORNER
WALL CORNER
WALL CORNER
WALL CORNER
END WALL
BEGIN WALL
BEGIN WALL
TOW
130.70
130.61
131.00
131.00
130.70
130.70
130.70
130.70
5 6
7 8
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
13C04
16 CIVIL
CAMPUS OAKS
PERIMETER WALL IMPROVEMENTS
11843A1013C004.dwg
hgarcia 12/11/2024 8:34:15 AM Plot Date: 0 10' 20' 40'
SCALE: 1" = 20'
usanorth811.org
1. THE PLANS HAVE BEEN PREPARED IN PART
BASED ON AVAILABLE RECORD INFORMATION.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL EXISTING CONDITIONS PRIOR TO BEGINNING
THE WORK.
2. SURFACE RESTORATION REQUIRED AT
TRENCHES AND EXCAVATION IS NOT SHOWN ON
THESE PLANS.
GENERAL NOTES:
SCALE:
FILE:
A SECTION
- 1/2" = 1-0"
11843A1013S310
WEST, SOUTH, AND EAST PERIMETER WALL
3'-0" 1'-9 1/2" 8'-2 1/2" 1'-4" 10'-0"
12" CMU
HP EL 130.80± HP EL 131.00±
TOC EL 129.00
EXTENT OF WALL
FOOTING
A
-
TOW EL 139.00±
PAINTED DESERT DRIVE
NEW MEADOW DRIVE (FUTURE)
B
-
SCALE:
FILE:
B SECTION
- 1/2" = 1-0"
11843A1013S310
NORTH PERIMETER WALL
3'-0" 1'-9 1/2" 8'-2 1/2" 1'-4" 10'-0"
12" CMU
HP EL 130.80± HP EL 131.00±
TOC EL 129.00
TOW EL 139.00±
ROLLING GATE,
SEE SPEC
SECTION 02820
PEDESTRIAN
GATE TYP
CF200
20' 20'
NOTES:
1. SEE SECTION A FOR
REINFORCEMENT.
#4 @ 24"
#6 @ 8" LAP
#4 @ 8"
T&B
#6 @ 8"
#4 @ 8"
OUTSIDE INSIDE OUTSIDE INSIDE
Plot Date: 12/11/2024 8:35:34 AM PROJECT NO. LAST SAVED BY: FILE NAME:
MED
HPG
DM
13C05
17 CIVIL
CAMPUS OAKS
DETAILS AND SECTIONS
11843A1013C005.dwg hgarcia
12" SD
SCALE:
FILE:
1 DETAIL
13C01 1/2" =1'-0"
11843A10C400
BACKFLUSH AIR GAP
GENERAL NOTES:
1. CONTRACTOR TO FIELD VERIFY PIPE CONFIGURATION AT BURIED VALVE AND NOTIFY ENGINEER OF ANY DISCREPANCIES.
SEE CIVIL PLANS AND PROFILES FOR PIPE
ORIENTATION, COORDINATES AND
ELEVATIONS. PIPE PENETRATIONS SHOWN
SCHEMATICALLY IN THIS DETAIL (TYP)
10" AF
12" X 10" REDUCER ELBOW
12" AF
CONCRETE PIPE
ENCASEMENT
AC PAVEMENT
CLASS 2 ABC
AT 95% RELATIVE
COMPACTION
SCARIFY NATIVE SOIL
AND COMPACT TO 95%
RELATIVE COMPACTION
UNDISTURBED NATIVE SOIL
SCALE:
FILE:
2 DETAIL
13C01 1" =1'-0"
11843A10C400
ASPHALT CONCRETE PAVEMENT 3" 9" 10"
CONCRETE CURB
SCALE:
FILE:
A SECTION
13C05 1/2" =1'-0"
11843A10C400
BACKFLUSH AIR GAP 9" 6"
6" (TYP ALL AROUND)
10" AF
12" AF
12" SD
4'-0"
1 12" ABC
CONCRETE PIPE
ENCASEMENT
TYP
CY119
TYP
MP140
8"
MIN
2'-0"
MIN 12" MAX
CONCRETE CURB
SIMILAR TO CR100/TYP
WITH 2 EA #4 BAR LOOPS
AND UNISTRUT FOR
SAMPLE LINE
TWO
FROM MONITORING
WELL
PRECAST
CONCRETE
NOTE 1
8"
1'-0"
5'-10"
DECHLORINATION TABLET
BASKET, WELDED GALV.
EXPANDED STEEL.
SEE DETAIL 1/-
8"
1'-0" 10"
PIPE SUPPORT
8" MIN MIN 6" ABC UNDER CURB
1" SAM
SCALE:
FILE:
1 DETAIL
- NO SCALE
11843A10C400
DECHLORINATION BASKET
DECHLORINATION TABLET
INLET CHUTE, 3" PIPE
FABRICATED GALVANIZED
EXPANDED STEEL BASKET
WELDED TO FLANGE
FINISHED GRADE,
SEE CIVIL PLANS
TYP
MP034 AIR-GAP 2 PIPE DIAMETERS 1'-0"
TYP
SD503
(TWO) 1" SAMPLE LINE
FROM THE EXISTING
MONITORING WELL
SLOPE 1/4"/FT
TOWARDS THE PIPE.
A
-
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
12" SD 3'-9" MAX
TYP
CP175
ISOLATION JOINT
FLANGE KIT
KEY NOTES:
1. 2" H-20 RATED WELDED GALVANIZED STEEL GRATING. 1'-0"
COORDINATE CONTROL POINTS
POINT
31 32
33 34
NORTHING
2050885.33
2050795.33
2050795.33
2050885.33
EASTING
6754987.94
6754987.95
6754959.94
6754959.94
DESCRIPTION
BLDG CORNER
BLDG CORNER
BLDG CORNER
BLDG CORNER
PRESSURE PIPE COORDINATES POINTS
POINT NUMBER
35 36
41 42
43 44
45 46
47 48
51 52
53 54
55 56
57 58
59 NORTHING
2050848.58
2050831.58
2050813.54
2050796.08
2050796.08
2050881.52
2050887.39
2050845.76
2050883.47
2050883.47
2050901.40
2050899.87
2050896.96
2050893.96
2050899.90
2050899.91
2050864.16
2050901.40
2050901.40
EASTING
6754953.94
6754953.94
6754894.75
6754894.77
6754892.00
6754891.94
6754897.82
6754921.98
6754921.98
6754909.28
6754970.22
6754970.22
6754970.22
6754969.09
6754969.10
6754955.23
6754955.23
6754969.09
6754958.44
CL ELEVATION
124.00
124.00
127.98
127.25
127.25
127.25
127.25
124.54
124.54
124.54
118.07
118.07
118.07
121.07
126.43
127.75
127.95
125.00
125.47
DESCRIPTION
12" STUB
12" STUB
1" 90° ELL
1" TEE
1" 90 ELL
1" 90 ELL
1" 90 ELL
10" 90° ELL
10" 90° ELL
10" 90° ELL
16" X 4" TEE
16" X 2" TEE
16" 45 ELL
16" 45 ELL
2" 90 ELL
2" 90 ELL
2" 90 ELL
4" 90 ELL
4" 90 ELL
YARD PIPING STRUCTURES COORDINATES POINTS
POINT NUMBER
61 62
63 64
65 66
68 69
71 73
NORTHING
2050887.39
2050887.43
2050887.39
2050887.41
2050789.00
2050788.60
2050789.44
2050837.24
2050881.26
2050927.18
EASTING
6754901.70
6754909.28
6754940.60
6754993.09
6754940.53
6754894.76
6754990.74
6754940.53
6754932.45
6754889.33
DESCRIPTION
CB-1A
SD AIR-GAP STRUCTURE
CB-1
CB-1C
CB-3
CB-3A
CB-3B
CB-2
SSMH-1
SSMH-0
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
13C06
18 CIVIL
CAMPUS OAKS
COORDINATE POINTS
11843A1013C006.dwg
hgarcia 12/11/2024 8:37:28 AM Plot Date:
8" BLOCK WALL
SET 5/8" REBAR WITH CAP
N. 2043588.864
E. 6755857.263
ELEV.=134.65
SET 5/8" REBAR WITH CAP
N. 2043520.796
E. 6756192.466
ELEV.=129.70
"NO PARKING"
ELEC. PB
DI GRATE EL.= 131.21
FL 12" RCP E = 118.76
DI GRATE EL.= 122.74
ELEC. BOX
GUARD RAIL
COMM MH
RIM=124.28
USA MARKING
(GREEN)
SEWER MANHOLE
RIM=116.77
INV.12"N=102.67
INV.12"S=102.77
SEWER MANHOLE
RIM=116.73
(LID LOCKED)
30" TREE
10" TREE
36" TREE 6" TREE
8" TREE
6" OAK
20" TREE
8" TREE
6" TREE
10" TREE
24" OAK
36" OAK
48" 0AK
36" OAK
8" OAK
30" OAK
24" OAK 36" OAK
30" OAK
48" OAK
36" OAK
24" OAK
16" OAK
20" OAK
30" OAK
10" OAK
12" OAK
14" OAK
10" OAK
8" OAK
8" OAK
12" OAK
24" OAK
12" OAK
6" OAK
8" OAK 6" OAK
36" OAK
30" OAK
24" OAK
6' WROUGHT IRON FENCE
4' CHAIN LINK FENCE
2.5' WOOD POST & CABLE FENCE
SEWER MANHOLE
RIM=122.88
INV.12"E=112.08
INV.12"S=112.38
INV.12"W=112.68
INV.12"NW=112.58
CONCRETE HEADWALL
N. 2043729.554
E. 6756442.766
ELEV.=114.76
SET 60D NAIL
CL TWIN BOX CULVERTS
APPROX 10'x10'±
INV.12"SE = 128.06
INV12"=108.21
END STORM PIPE
6' WROUGHT IRON FENCE
STORM DRAIN MANHOLE
RIM EL. = 131.86
INV.12"NW = 125.21
INV.18"SE = 125.26
INV.18"= 125.11
INV.18"SW = 125.11
125
127
126
124
129
131
132
131
131
131
131
131
131
130
133
134
135
136
136
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
19C00
19 CIVIL
MISTY WOOD
OVERALL SITE PLAN
11843A1019C000.dwg
hgarcia 12/11/2024 9:10:13 AM Plot Date:
0 15' 30' 60'
SCALE: 1" = 30'
usanorth811.org
SEWER TIE-IN
LOCATION
ASR FACILITY
STORM DISCHARGE
LOCATION
5 19C05
R50'
1270 PLEASANT GROVE BLVD
SEWER STATION LIFT
2" SFM
ASR WELL
REMOVE EXISTING BOMANITE
HERRINGBONE PATTERN
BRICKWORK ON THE
DRIVEWAY AND REPLACE TO
MATCH EXISTING
EXISTING 16" CONCRETE BAND WITH 8" SOLDER
COURSE AND HERRINGBONE BOMANITE
BRICKWORK. BOMANITE COLOR SHALL BE
MEXICAN TILE WITH AUTUMN BROWN RELEASE.
REFER TO IMPROVEMENTS PLANS FOR
WOODCREEK OAKS VILLAGE 3 RECORD
DRAWINGS, PROVIDED BY THE CITY
8" BLOCK WALL
SET 5/8" REBAR WITH CAP
N. 2043588.864
E. 6755857.263
ELEV.=134.65
SET 5/8" REBAR WITH CAP
N. 2043520.796
E. 6756192.466
ELEV.=129.70
"NO PARKING"
ELEC. PB
DI GRATE EL.= 131.21
COMM MH
RIM=124.28
30" TREE
10" TREE
36" TREE 6" TREE
8" TREE
6" OAK
20" TREE
8" TREE
6" TREE
10" TREE
24" OAK
36" OAK
48" 0AK
36" OAK
8" OAK
30" OAK
24" OAK 36" OAK
36" OAK
24" OAK
16" OAK
30" OAK
24" OAK
6' WROUGHT IRON FENCE
2.5' WOOD POST & CABLE FENCE
INV.12"SE = 128.06
6' WROUGHT IRON FENCE
STORM DRAIN MANHOLE
RIM EL. = 131.86
INV.12"NW = 125.21
INV.18"SE = 125.26
INV.18"= 125.11
INV.18"SW = 125.11
125
127
126
124
129
131
132
130.90
130.50
130.50
131.40
131.40
130.95
130.61
135.38
134.50
128.54
128.91
129.82
129.99
130.80
130.30
130.80
131.25
HP 131.40
131.35
131.35
HP 131.45
HP 131.20
131.20
131.50
130.90
131.00
130.90
131.00
131.10
131.21
131.20
130.65
131.00
131
131
131
131
131
131
130
130.80
130.90
131.20
130.40
131.40
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
131.40
131.40
132
134
133
136
135
136
131.20
131.20
131.28
131.42
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
5 19C05
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
19C01
20 CIVIL
MISTY WOOD
PAVING, GRADING, AND SITE PLAN
11843A1019C001.dwg
hgarcia 12/11/2024 12:16:02 PM Plot Date: 0 10' 20' 40' SCALE: 1" = 20'
WELL
BUILDING
3 5
9 2
8 6
7 16
1 TYP
CR110
10 TOC 131.50
EX MONITORING WELL
11 125'
103'
13 14
12 KEY NOTES:
1. FUTURE WATER TREATMENT FILTER VESSELS
AND BACKWASH TANK.
2. FUTURE FILTER BACKWASH TANK.
3. ELECTRICAL TRANSFORMER, SEE 19E01.
4. 2" BACKFLOW PREVENTER INSTALL SIMILAR TO
CITY OF ROSEVILLE STANDARD DETAIL W-7.
5. FIBER OPTIC HANDHOLE, SEE 19E01.
6. AUTOMATIC GATE OPENER PER SECTION 02820.
7. AUTOMATIC ROLLING GATE PER SECTION 02820.
8. GATE KEY PAD PER SECTION 02820.
9. AIR-GAP STRUCTURE TO STORM DRAIN. SEE
19C05 FOR DETAILS.
10. FUTURE AIR GAP STRUCTURE TO SEWER.
11. CMU WALL (REFER TO 13C04 FOR COORDINATE
POINTS).
12. PAVED DRIVE WAY.
13. FUTURE LOCATION FOR FIRE PROTECTION
BACKFLOW AND FDC ASSEMBLY PER CITY OF
ROSEVILLE STANDARD DETAIL W-2.
14. FLOWMETER INSTALL SIMILAR TO CITY OF
ROSEVILLE STANDARD DETAIL W-7.
15. CONDENSING UNIT, SEE MECHANICAL DRAWINGS.
16. CONCRETE LANDING, SLOPED AT 1/4" PER FOOT
FOR DRAINAGE PER CR306/TYP.
17. PEDESTRIAN ACCESS GATE.
GENERAL NOTES:
1. THE PLANS HAVE BEEN PREPARED IN PART
BASED ON AVAILABLE RECORD INFORMATION.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL EXISTING CONDITIONS PRIOR TO BEGINNING
THE WORK.
2. SURFACE RESTORATION REQUIRED AT
TRENCHES AND EXCAVATION IS NOT SHOWN ON
THESE PLANS.
3. SEE DETAIL 2/19C05 FOR TYPICAL PAVEMENT
SECTION.
4. CONTRACTOR SHALL FOLLOW TREE PERMIT
REQUIREMENTS, SEE SPECIFICATION 01562.
5. SEE CITY STANDARD CONSTRUCTION
SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
6. SLOPE ALL FINISHED PAVEMENT WITHIN 4 FEET
AT A MINIMUM OF 2% SLOPE AWAY FROM
STRUCTURE.
16 15
17 4
usanorth811.org
X
KEY NOTES CONT'D:
18. REMOVE AND REPLACE EXISTING CONCRETE
SQUARE CURB AND GUTTER WITH DEPRESSED
CURB PER CITY STANDARD DETAIL ST-21. START
AND STOP AT EXISTING SCORE MARKS OR
JOINTS.
19. REMOVE AND REPLACE EXISTING 8 FT WIDE
CONCRETE SIDEWALK. MATCH EXISTING
CONCRETE COLOR AND FINISH. START AND STOP
AT EXISTING SCORE MARKS OR JOINTS.
20. THE CONTRACTOR SHALL PROVIDE A
TEMPORARY SAFE, SMOOTH, AND FIRM
PEDESTRIAN ACCESS ALONG THE EXISTING
SIDEWALK PATHWAY.
21. ESTABLISH NEW 2'-6" POST AND CABLE FENCE TO
MATCH EXISTING.
22. FIRE HYDRANT AND 6" GATE VALVE PER CITY OF
ROSEVILLE STANDARD DETAIL W-13 AND W-16.
23. IRRIGATION CONTROL PANEL AND CONDUIT.
POST MOUNT OR SURFACE MOUNT ON
PERIMETER WALL.
24. REMOVE EXISTING SMALL TREES, (LESS THAN 6"
DIAMETER) AND CUT LIMBS TO PROVIDE 10'
CLEARANCE. COORDINATE WITH CITY ARBORIST.
25. INSTALL 10 FT WIDE IRRIGATED LANDSCAPED
STRIP WITH CITY APPROVED SCREENING BUSHES
OR TREES.
26. LIMITS OF DISTURBANCE/CONTRACTOR WORK
AREA.
27. ALLOWANCE ITEM #1 REPLACE EXISTING
RESIDENTIAL WROUGHT IRON FENCE.
28. KEYSTONE STYLE BLOCK WALL.
29. CONCRETE LANDING PAD, MIN 2% SLOPE TO
DRAIN.
30. POLE FOR LICENSE PLATE READER CAMERAS,
SEE ELECTRICAL DRAWINGS.
31. INSTALL "NO PARKING" SIGN.
32. HAND PLACE 4"-6" RIP RAP AT BOTH ENDS OF THE
CROSS GUTTER, WITH FILTER FABRIC
UNDERLAYMENT.
33. ELECTRICAL PULL BOX, SEE 19E01.
34. NOT USED
X
25 23
25 20
20 20
18 5'
5'
22 19
18 19
5'
5'
LAPORTE DR PLEASANT GROVE BLVD
10'
10'
10'
10'
3 19C05
1 19C05
TYP
CF200
28 27
26 24
24 6" OAK
R45'
R55'
R27'
R71.46'
20'
R
19M12
R37.16'
31 21
21 30
32 32
TYP
CR110
TYP
CR110
GRASS-LINED SWALE,
FINISHED GRADE TO DRAIN TO
THE SOUTHWEST CORNER
GRASS
LINED
SWALE
33 34
26 12
11 12
29 8" BLOCK WALL
FOUND 1 1/2" BRASS DISK WITH
PUNCH IN MONUMENT WELL
"NO PARKING"
STORM DRAIN MANHOLE
RIM EL. = 131.86
FL 12" RCP NW = 125.21
FL 18" RCP SE = 125.26
FL 18" RCP NE = 125.11
ELEC. PB
2.5' WOOD POST & CABLE FENCE
6' WROUGHT IRON FENCE
FL 18" RCP SW = 125.11
FL 12" RCP SE = 128.06
DI GRATE EL.= 131.21
W
UGE
UGE FO
FO
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
W
W
W
W
W
W
52 87
88 89
85 86
84 81
82 90
83 53
54 51
58 59
60 57
56 55
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
KEY NOTES:
1. (1) 2" CONDUIT WITH FIBER OPTIC CABLE AND (1)
2" CONDUIT SPARE WITH PULL WIRE.
2. (1) 4" CONDUIT POWER AND (1) 4" CONDUIT SPARE
WITH PULL WIRE, PER ROSEVILLE ELECTRIC
REQUIREMENTS.
3. CONNECT TO EXISTING 12" SD.
4. EXISTING 4" BLOW OFF.
5. NOT USED.
6. CONNECT TO EXISTING SSMH. DROP INLET OR
OTHER SIMILAR TO CITY OF ROSEVILLE
STANDARD DETAILS SS-12.
7. STUB OUT FOR FUTURE CONNECTION.
8. PROVIDE 4" DIP WITH BLIND FLANGE AND BLOW
OFF 24" ABOVE FINISHED GRADE. TYPICAL OF
THREE LOCATIONS.
9. ROUTE EACH 1" SAMPLE LINE FROM EXISTING
MONITORING WELL TO INSIDE THE BUILDING
(TWO TOTAL). ROUTE SAMPLE LINE TO AVOID
OTHER UTILITIES. WORK INCLUDES ALL FITTINGS,
WALL PENETRATIONS, AT-GRADE HANDHOLES,
AND PIPE SUPPORTS AS REQUIRED.
10. ROUTE EACH 1" SAMPLE LINE FROM EXISTING
MONITORING WELL TO THE SD AIR GAP
STRUCTURE (TWO TOTAL).
11. ENCASE 4" DRAIN IN CONCRETE FROM THE
BUILDING TO THE MANHOLE INSTALL TWO
FLEXIBLE COUPLINGS (FLEX-SEAL ARC SHIELDED
ADJUSTABLE SEWER REPAIR COUPLING MR56
ARC SERIES OR EQUAL) TO ALLOW FOR
DEFLECTION BETWEEN THE BUILDING AND
MANHOLE.
12. BACKFLOW PREVENTER AND FLOWMETER PER
CITY OF ROSEVILLE STANDARD DETAIL W-7.
13. FIRE HYDRANT AND 6" GATE VALVE PER CITY OF
ROSEVILLE STANDARD DETAIL W-13 AND W-16.
14. SPECIAL TRENCH: CUT PAVEMENT RESTORATION
SECTION PER CITY STANDARD TB-6, 3' BEHIND
THE BACK OF CURB, TYP OF ALL WORK IN PAVED
AREA.
15. CONTRACTOR SHALL POTHOLE TO IDENTIFY
EXISTING UTILITY CROSSINGS ALONG THE
PROPOSED SEWER FORCE MAIN. SUBMIT A
CONSTRUCTION PLAN TO THE ENGINEER FOR
REVIEW AND APPROVAL.
16. STORM DRAIN MANHOLE PER CITY OF ROSEVILLE
STANDARD DETAIL DR-4 WITH DETAIL DR-8 GRATE
COVER.
GENERAL NOTES:
1. SEE GENERAL NOTES ON SHEET 00G04 AND CIVIL
NOTES ON 00GC01.
2. REFER TO DEMOLITION DRAWINGS FOR
REQUIRED SITE WORK.
3. REFER TO PIPE PROFILES FOR INVERT
ELEVATIONS NOT CALLED OUT ON THE PLANS.
MAINTAIN MINIMUM 36" COVER WHERE ANY
INVERT ELEVATION IS NOT IDENTIFIED.
4. PIPE TRENCHING AND SURFACE RESTORATION
SHALL BE PER THE CITY OF ROSEVILLE
STANDARD DETAILS AND CY111/TYP.
5. THE CONTRACTOR SHALL RESTORE ALL
LANDSCAPING AND IRRIGATION COMPONENTS
PER THE CITY OF ROSEVILLE STANDARDS WHERE
DISTURBED AS A RESULT OF THIS WORK. PLANTS
SHALL BE REPLACED IN KIND AND SIZE BY THE
CONTRACTOR.
6. REFER TO DRAWING 00GM05 FOR PIPE SCHEDULE
AND SECTION 15052 FOR GENERAL PIPING
REQUIREMENTS.
7. BURIED DI PIPE SHALL BE PROTECTED WITH A
CATHODIC PROTECTION SYSTEM OR WAX TAPE
PER SPECIFICATION 15320. ANODE AND TEST
STATION SPACING/PLACEMENT ARE
APPROXIMATE BASED ON OBSTACLES IN AREA
AND MAY BE MOVED. ALL ISOLATION FLANGES
MUST HAVE ISOLATION JOINT FLANGE KIT TEST
STATION INSTALLED AT THE LOCATION. ISOLATE
ALL DISSIMILAR PIPE, VALVES, ETC. ADD JOINT
BONDING TO DIP, REFER TO CP150 FOR JOINT
BOND DETAILS.
8. OFFSITE UTILITIES EXTENDED TO SITE BY
OTHERS. CONNECT TO SERVICES PROVIDED IN
FIELD.
X
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
19C02
21 CIVIL
MISTY WOOD
YARD PIPING AND UTILITIES PLAN
11843A1019C002.dwg
hgarcia 12/13/2024 7:02:19 PM Plot Date:
12" SD
2" SFM
16" PW
UGE
F/O
EX-36" W
EX-12" SD
EX-15" SD
EX-12" SD
EX-TELE
EX-X" GAS
EX-TELE
EX-CABLE
1 2
4 0 10' 20' 40'
SCALE: 1" = 20'
usanorth811.org
8" SD
8" SD
12" SD
12" SD
8" SD
12" SD
8" SS
EX-12" SD
7 8" SD
WELL
BUILDING
XFMR
FUTURE WATER TREATMENT
FILTER TANK
SEE 19M05 FOR CONTINUATION
AND CLEANOUT LOCATION
SEE 19M01 FOR
CONTINUATION
INSTALL WET WELL SUBMERSIBLE
GRINDER PUMP STATION IN
TRAFFIC RATED MANHOLE PER
SPECIFICATION 11309. PROVIDE
BUCK-BOOST TRANSFORMER
WITH VENDOR CONTROL PANEL.
GENERAL ALARM TO SCADA.
7 12" FI
7 7 12" FE
10" AF FUTURE AIR GAP
STRUCTURE TO SEWER
8 2" PW
4" FPW
8 TYP
CY716
4" GV
(EX) MONITORING WELL
FUTURE FILTER
BACKWASH TANK
REMOVE AND REPLACE
COLORED STAMPED
CONCRETE OR ASPHALT
1" SAM 10
FLOWMETER
SS VENT
11 INSTALL BUTTERFLY
ISOLATION VALVE AT
THE 16" PW TIE-IN.
12 CONDENSING
UNIT
13 (TWO EACH)
WD37-PUMP-30001
WD37-PUMP-30002
LAPORTE DR PLEASANT GROVE BLVD
2" BACKFLOW
12 PREVENTER
2" IRR
TYP
CP311
TYP
CP322
TYP
CP311
(TRAFFIC RATED)
TYP
CP311
(TRAFFIC RATED)
3 19C05
2" SFM
1" SAM
(TWO EACH)
9 3
1 19M12
2 19M12
9 (DIRECT
CONNECT
ANODE)
(TRAFFIC
RATED)
15 14
14 15
6 EXISTING 12" DI
EXISTING 12" DI
16 AIR GAP STRUCTURE
TO STORM DRAIN
CB5
CB1
CB6
CB7
CB2
CB3
CB4
CB5
SSMH
2" BACKFLOW
PREVENTER
12 15
15 CPTS
CPTS
CPTS
CPTS
CPTS
CPTS
CPTS
CPTS
1 19C05
R
19M12
S
19M12
EX UGE & FO
108
112
116
120
124
128
132
136
140
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 12+00 12+40
12" SD
12" SD 12" SD STA 10+00 EL 126.81 TIE-IN TO EXISTING CB1 STA 11+05.09 RIM 130.80 INV IN 127.59 (12" SE) INV OUT 127.79 (12" NW) INV OUT 127.79 (12" NE) INV OUT 127.79 (8" SW) CB5 STA 11+39.70 RIM 130.80 INV IN 128.04 (12" SE) INV OUT 128.24 (12" NW) INV OUT 128.24 (8" NE) CB2 STA 12+13.53 RIM 130.80 INV IN 128.86 (12" SE) INV OUT 129.06 (8" SW)INV OUT 129.06 (8" NE)
S=-0.72% S=-0.72%
S=-0.84%
(2) 2" IRR INV 129.0± 10" AF INV 122.1± (2) 1" SAM INV 128.3± 108
112
116
120
124
128
132
136
140
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 11+40
S=-0.84%
S=-0.81%
8" SD
8" SD CB7 STA 10+00 RIM 130.90 INV IN 129.46 (8" NE) CB2 STA 10+47.58 RIM 130.80 INV IN 128.86 (12" SE) INV OUT 129.06 (8" SW)INV OUT 129.06 (8" NE) CB3 STA 10+77.17 RIM 130.50 INV IN 129.30 (8" SW) 108
112
116
120
124
128
132
136
140
108
112
116
120
124
128
132
136
140
9+90 10+00 10+80
S=0.25% CB5 STA 10+00 RIM 130.80 INV IN 128.04 (12" SE) INV OUT 128.24 (12" NW) INV OUT 128.24 (8" NE) CB4 STA 10+39.58 RIM 130.30 INV IN 128.14 (8" SW) 8" SD
(2) 1" SAM INV 128.6
108
112
116
120
124
128
132
136
140
108
112
116
120
124
128
132
136
140
9+80 10+00 11+00 11+20 CB6 STA 10+00 RIM 130.90 INV IN 128.20 (8" NE) CB1 STA 10+47.59 RIM 130.80 INV IN 127.59 (12" SE) INV OUT 127.79 (12" NW) INV OUT 127.79 (12" NE) INV OUT 127.79 (8" SW) SD AIR-GAP STRUCTURE STA 10+79.10 RIM 130.90 INV IN 128.11 (12" SW) INV IN 128.10 (12" NE) 8" SS INV 124.1± S=-0.86%
8" SD
S=-1.00%
12" SD
S=1.00% CB8 STA 10+86.45 RIM 130.90 INV OUT 128.18 (12" SW) 4" FPW INV 129.0± 2" PW INV 129.0± PROJECT NO. LAST SAVED BY:FILE NAME: Plot Date:
MED
HPG
DM
19C03
22 CIVIL
MISTY WOOD
PIPE PROFILES
11843A1019C003.dwg
hgarcia 9/12/2022 7:29:07 AM
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1019C004
1"=20'
1"=5'
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROPOSED GRADE
EXISTING GRADE
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1019C004
1"=20'
1"=5'
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1019C004
1"=20'
1"=5'
PROFILE
FILE:
VERT SCALE:
HORIZ SCALE:
11843A1019C004
1"=20'
1"=5'
PROPOSED GRADE
EXISTING GRADE
PROPOSED GRADE
EXISTING GRADE
PROPOSED GRADE
EXISTING GRADE
GENERAL NOTES:
1. SEE GENERAL NOTES ON SHEET 00G04 AND CIVIL
NOTES ON 00GC01.
2. OFFSITE UTILITIES EXTENDED TO SITE BY
OTHERS. CONNECT TO SERVICES PROVIDED IN
FIELD.
3. EXISTING INVERT ELEVATIONS ARE BASED ON
AVAILABLE RECORD INFORMATION. CONTRACTOR
SHALL FIELD VERIFY INVERT ELEVATIONS PRIOR
TO BEGINNING THE WORK.
(2) 1" SAM INV 128.6± 129.166±
2 3
4 5
6 7
8 1
COORDINATE CONTROL POINTS
POINT
1 2
3 4
5 6
7 8
9 10
NORTHING
2043499.37
2043524.03
2043566.51
2043559.45
2043605.47
2043539.79
2043451.29
2043485.19
2043483.78
2043480.01
EASTING
6756031.54
6756056.38
6756014.00
6756006.92
6755961.02
6755895.18
6755983.46
6756017.44
6756016.02
6756012.25
DESCRIPTION
BEGIN WALL
WALL CORNER
WALL CORNER
WALL CORNER
WALL CORNER
WALL CORNER
WALL CORNER
END WALL
MAN DOOR
MAN DOOR
TOW
141.16
142.50
142.50
142.50
142.50
142.50
142.50
141.16
141.16
141.16
9 10
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
19C04
23 CIVIL
MISTY WOOD
PERIMETER WALL IMPROVEMENTS
11843A1019C004.dwg
hgarcia 12/11/2024 10:03:08 AM Plot Date:
A
-
0 10' 20' 40'
SCALE: 1" = 20'
usanorth811.org
PLEASANT GROVE BLVD
1. THE PLANS HAVE BEEN PREPARED IN PART
BASED ON AVAILABLE RECORD INFORMATION.
CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL EXISTING CONDITIONS PRIOR TO BEGINNING
THE WORK.
2. SURFACE RESTORATION REQUIRED AT
TRENCHES AND EXCAVATION IS NOT SHOWN ON
THESE PLANS.
GENERAL NOTES:
SCALE:
FILE:
A SECTION
- 1/2" = 1-0"
11843A1019S310
PERIMETER WALL
5'-0" 2'-9 1/2" 9'-10 1/2" 1'-4" 12'-8"
HP EL 131.4±
LP EL 128.54± TOC EL 128.50
TOW EL 141.16±
EXTENT OF WALL FOOTING
TOW AT CORNERS (8')
EL 142.5±
HP EL 135.38±
1. ALLOWANCE ITEM #1 REPLACE EXISTING
RESIDENTIAL WROUGHT IRON FENCE.
KEY NOTES:
1 12" CMU
#4 @ 24"
#6 @ 8" LAP
#4 @ 8"
T&B
#6 @ 8"
#4 @ 8" EL 127
ROLLING GATE, SEE
SPEC SECTION 02820
PEDESTRIAN GATE
TYP
CF200
20'
5.33'
OUTSIDE INSIDE
Plot Date: 12/11/2024 10:16:39 AM PROJECT NO. LAST SAVED BY: FILE NAME:
MED
HPG
DM
19C05
24 CIVIL
MISTY WOOD
DETAILS AND SECTIONS
11843A1019C005.dwg hgarcia
12" SD
A
-
SCALE:
FILE:
1 DETAIL
19C01 1/2" =1'-0"
11843A10C400
BACKFLUSH AIR GAP
GENERAL NOTES:
1. CONTRACTOR TO FIELD VERIFY PIPE CONFIGURATION AT BURIED VALVE AND NOTIFY ENGINEER OF ANY DISCREPANCIES.
SEE CIVIL PLANS AND PROFILES FOR PIPE
ORIENTATION, COORDINATES AND
ELEVATIONS. PIPE PENETRATIONS SHOWN
SCHEMATICALLY IN THIS DETAIL (TYP)
10" AF
12" X 10" REDUCER ELBOW
12" AF
AC PAVEMENT
CLASS 2 ABC
AT 95% RELATIVE
COMPACTION
SCARIFY NATIVE SOIL
AND COMPACT TO 95%
RELATIVE COMPACTION
UNDISTURBED NATIVE SOIL
SCALE:
FILE:
2 DETAIL
19C01 1" =1'-0"
11843A10C400
ASPHALT CONCRETE PAVEMENT 3" 9" 10"
CONCRETE CURB
SCALE:
FILE:
A SECTION
19C05 1/2" =1'-0"
11843A10C400
BACKFLUSH AIR GAP 9" 6"
6" (TYP ALL AROUND)
10" AF
12" AF
12" SD
12" ABC
CONCRETE PIPE
ENCASEMENT
TYP
CY119
TYP
MP140 3'-9" MAX
8"
MIN
2'-0"
MIN 12" MAX
PRECAST
CONCRETE
NOTE 1
5'-10"
SCALE:
FILE:
C SECTION
- NO SCALE
11843A10C400
ENERGY DISSIPATOR PROFILE
PHOTO
FILE:
5 19C00
STORM DRAIN OUTLET TO CREEK ENERGY DISSIPATOR
FILE
3'-0"
3'-0"
6'-0"
STORM DRAIN
OUTLET
12" RIP RAP ROCK OVER FILTER FABRIC, EXTEND 1
FT BEYOND ROCK. PLACE CLASS I ROCK SLOPE
PROTECTION (RSP) OVER CLASS 8 RSP FABRIC
ACCORDING TO CALTRANS STANDARD
SPECIFICATIONS. HAND PLACE RSP TO WITHIN 3
INCHES OF THE PIPE INVERT AT THE WALL. RSP MAY
BE TAPERED TO A DEPTH OF 8 TO 12 INCHES AT THE
EDGES OF THE PLACEMENT AREA. FABRIC TO BE
PLACED WITHOUT EXCAVATION. NO DUMP
PLACEMENT OF RSP SHALL BE PERMITTED. RSP
AREA SHALL NOT ENTER THE NORMAL FLOW
CHANNEL; IT IS ONLY FOR EROSION PROTECTION OF
THE NEAR-BANK AREA DIRECTLY BELOW THE
DISCHARGE PIPE.
C
-
6'-0"
STORM DRAIN OUTLET
4'-0"
1 CONCRETE CURB
SIMILAR TO CR100/TYP
WITH 2 EA #4 BAR LOOPS
AND UNISTRUT
PIPE SUPPORT
8" MIN MIN 6" ABC UNDER CURB
12" RIP RAP ROCK
EXISTING CONCRETE
DRAINAGE STRUCTURE
EXTEND FABRIC
1 FT ALL SIDES
EXISTING GRADE
CONCRETE PIPE
ENCASEMENT
(TWO) 1" DRAIN LINE
FROM THE EXISTING
MONITORING WELL
TYP
SD503
(TWO)
FROM MONITORING
WELL
1" SAM
TYP
MP034
8"
1'-0"
DECHLORINATION TABLET
BASKET, WELDED GALV.
EXPANDED STEEL.
SEE PHOTO 4 ON THIS SHEET
8"
1'-0" 10"
FINISHED GRADE,
SEE CIVIL PLANS AIR-GAP 2 PIPE DIAMETERS 1'-0"
SLOPE 1/4"/FT
TOWARDS THE PIPE.
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
12" SD
PHOTO
FILE:
4 -
DECHLORINATION BASKET
FILE
DECHLORINATION
TABLET INLET CHUTE,
3" PIPE
FABRICATED GALVANIZED
EXPANDED STEEL BASKET
WELDED TO FLANGE
TYP
CP175
ISOLATION JOINT
FLANGE KIT
OD OF MANHOLE + 12" 6" CLR 12" MIN
#5 @ 12" EW
CAST-IN-PLACE CLASS "A"
CONCRETE BASE. CAST BASE
AGAINST UNDISTURBED SOIL
OR 8" MIN ABC UNDER BASE
WHERE SOIL IS UNSTABLE.
SCALE:
FILE:
3 DETAIL
19C01
19C02
NO SCALE
11843A10C400
GRINDER PUMP STATION
4" DR
(FROM THE
BUILDING)
INV EL
123.37 3'-0" 2'-6" 2'-6"
PACKAGED DUPLEX
GRINDER PUMP STATION
PER SECTION 11309
PRECAST CONCRETE
MANHOLE RISERS WITH
VARIABLE HEIGHT
SIZE PUMP PER
MANUFACTURER
REQUIREMENTS
2" SFM
(TO THE SS MANHOLE TIE-IN)
SEE CIVIL DRAWINGS FOR FITTINGS LOCATION
BACKFILL WITH CLSM
ELEC
MIN 3'-0" ID 5'-0" MIN DEPTH
ENSURE ADEQUATE SPACE
BETWEEN MANHOLE AND PUMP
STATION TO ALLOW CONNECTION
OF ELECTRICAL CONDUIT, PIPING
AND OTHER COMPONENTS
(TO THE BLDG,
SEE CIVIL)
(TO THE CONTROL PANEL
IN THE CHEMICAL ROOM)
VENT TO NORTHEAST SIDE OF
BUILDING, RUN UP ADJACENT
TO ROOF DRAIN, MIN HEIGHT
2'. COORDINATE VENT SIZE
WITH MANUFACTURER
SS VENT
LOCATE PANEL INSIDE OF CHEM
ROOM. COORDINATE CONDUIT
RUNS WITH BUILDING FOUNDATION
MIN 5'-0" ID
PROVIDE SST HOOK
GRADE RINGS FOR LIFTING ROPE
AS REQUIRED
MORTAR
AC PAVEMENT OR
SOIL BACKFILL
PROVIDE 30" MIN H-20 TRAFFIC RATED MANHOLE COVER
AND FRAME WITH FLAT TOP COVER. FINISH MH COVER PER
CS110/TYP INCLUDING GRADE RINGS, CLASS A CONCRETE
FINAL SIZE AND LOCATION WITH PUMP MANUFACTURER.
# KEY NOTES:
1. 2" H-20 RATED WELDED GALVANIZED STEEL GRATING.
CLASS "A" CONCRETE
CORE DRILL CONCRETE AND SEAL
SPACE WITH NON-SHRINK GROUT
PER CITY STANDARDS, TYP ALL
MANHOLE PENETRATIONS
DISCHARGE ELEVATION PER PUMP
PACKAGE MANUFACTURER
TYP
CS110 (SIM TO)
FINISHED GRADE PER CIVIL DRAWINGS
TYP
MP218
FROM MONITORING WELL
FROM
MONITORING
WELL
TO PUMP
ROOM
B
-
SCALE:
FILE:
B SECTION
- NO SCALE
11843A10C400
BACKFLUSH AIR GAP
PREFORMED CHANNEL
PIPE SUPPORT
CONCRETE CURB
FINISHED GRADE
SEE CIVIL PLANS
TYP
MP218
1" SAM
(TWO EACH)
1" SAM
(TWO EACH) FROM
MONITORING
WELL
TO PUMP
ROOM 1'-0"
EXISTING BLOCK EROSION PROTECT
2" MINIMUM
AIR GAP
COORDINATE CONTROL POINTS
POINT
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
NORTHING
2043556.00
2043492.29
2043472.51
2043536.23
2043476.15
2043449.89
2043392.52
2043368.12
2043441.87
2043502.15
2043502.53
2043522.17
2043499.58
2043526.48
2043555.28
2043393.08
EASTING
6755932.67
6755996.23
6755976.41
6755912.85
6756026.31
6756038.88
6756045.65
6756041.83
6756061.65
6756104.96
6756066.73
6756102.97
6756031.86
6756220.79
6756258.31
6756067.41
DESCRIPTION
BLDG CORNER
BLDG CORNER
BLDG CORNER
BLDG CORNER
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
EP
YARD PIPING STRUCTURES COORDINATE POINTS
POINT NUMBER
81 82
83 84
85 86
87 88
89 90
NORTHING
2043463.00
2043496.60
2043518.88
2043524.06
2043521.11
2043549.06
2043539.77
2043573.38
2043594.27
2043485.53
EASTING
6755982.96
6756016.65
6756038.94
6756044.16
6755992.20
6756020.23
6755906.37
6755940.06
6755961.00
6755998.27
DESCRIPTION
CB6
CB1
SD AIR-GAP STRUCTURE
CB
CB5
CB4
CB7
CB2
CB3
SS MH
PRESSURE PIPE COORDINATE POINTS
POINT NUMBER
51 52
53 54
55 56
57 58
59 60
NORTHING
2043423.17
2043419.22
2043533.28
2043526.85
2043391.15
2043466.94
2043469.53
2043546.29
2043529.69
2043523.67
EASTING
6756051.57
6756055.51
6755961.22
6755967.64
6756055.49
6756007.90
6756005.32
6756023.53
6756040.17
6756034.16
CL ELEVATION
124.33
123.97
124.33
124.33
121.99
124.33
124.33
122.54
122.54
122.54
DESCRIPTION
16" X 6" TEE
16" 45° ELL
12" STUB
12" STUB
16" X 6" TEE
16" X 6" CROSS
16" X 6" TEE
10" 90° ELL
10" 90° ELL
10" 90° ELL
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
PROJECT NO. LAST SAVED BY:FILE NAME:
MED
HPG
DM
19C06
25 CIVIL
MISTY WOOD
COORDINATE POINTS
11843A1019C006.dwg
hgarcia 12/11/2024 3:31:15 PM Plot Date:
SCHEDULE ABBREVIATION LIST:
B:
ci:
CMU:
CONC:
EXPO:
F-1:
FACT FIN:
GYP:
HW:
MATL:
MTL DECK
N/A
NR:
PAMP:
PR:
REQ:
SEALER:
U-FACTOR:
WDECK:
WFRP:
INT CLR:
BUSINESS GROUP (2022, TITLE 24)
CONTINUOUS INSULATION
INTEGRALLY COLORED CONCRETE MASONRY UNIT, REFERENCE
SPECIFICATION SECTION 04220
CONCRETE
EXPOSED MATERIAL
FACTORY INDUSTRIAL GROUP, MODERATE HAZARD OCCUPANCY
(2022, TITLE 24)
FACTORY FINISH
GYPSUM WALL BOARD, REFERENCE SPECIFICATION SECTION
09250
HARDWARE GROUP, REFERENCE SPECIFICATION SECTION 08710
MATERIAL
METAL DECK PER STRUCTURAL DESIGN
NOT APPLICABLE
NOT REQUIRED
PERFORATED ACOUSTICAL METAL PANELS. SYSTEM SHALL EXTEND TO THE UNDERSIDE OF GYP CEILING. REFERENCE SPECIFICATION SECTION 09523
PAIR
REQUIRED
FLOOR COATING, REFERENCE SPECIFICATION SECTION 09960
THERMAL TRANSMITTANCE, IS THE COEFFICIENT OF HEAT
TRANSMISSION (AIR TO AIR) THROUGH A BUILDING COMPONENT OR
ASSEMBLY, EQUAL TO THE TIME RATE OF HEAT FLOW PER UNIT
AREA AND UNIT TEMPERATURE DIFFERENCE BETWEEN THE WARM
SIDE AND COLD SIDE AIR FILMS (2022, TITLE 24)
WOOD DECK PER STRUCTURAL DESIGN
STANDARD FRP WALL SYSTEM, SMOOTH FINISH, LIGHT GRAY S490N AS MANUFACTURED BY MARLITE OR EQUAL. FRP SHALL BE
INSTALLED AT THE PERIMETER (INTERIOR FACE) OF THE FOUR
RESTROOM WALLS, THE FRP WALL SYSTEM SHALL BE 4'H FROM
FINISH FLOOR.
INTEGRAL COLOR
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:32 PM
R:\d1341480\11843A1013A0801.rvt
13GA01
CAMPUS OAKS ASR WELL
BUILDING CODE ANALYSIS, AND SCHEDULES 26
ARCHITECTURAL
JCA
FVG
MEH
2022 CALIFORNIA BUILDING CODE, TITLE 24, PART 2, VOL.1 & 2 BUILDING NAME, ROOM #, & ROOM WITHIN
STRUCTURE CONST.
TYPE
OCCUPANCY
CLASSIFICATION
ALLOW.
STORIES/HEIGHT
ACTUAL
STORIES/HEIGHT
ALLOW.
AREA (EA.
FLOOR)
ACTUAL
FLOOR AREA
(EA. FLOOR)
OCCUPANT
LOAD
FACTOR
ACTUAL
OCCUPANT
LOAD
NO. OF EXITS
REQ/ PROVIDED
OCCUPANCY
SEPARATION
FIRE
SUPPRESSION
ACCESSIBILITY
ROOM # ROOM NAME
101 PUMP ROOM V-B F-1 1 STORIES/40 '-0" 1 STORY/14 '-0" 8,500 1,123 SF 300 4 1/1 NR NO *NR 102 RESTROOM V-B B 1 STORIES/40 '-0" 1 STORY/14 '-0" 9,000 65 SF 100 1 1/1 NR NO R 103 CHEMICAL ROOM V-B F-1 1 STORIES/40 '-0" 1 STORY/14 '-0" 8,500 501 SF 300 2 1/2 NR NO *NR 104 ELECTRICAL ROOM V-B F-1 1 STORIES/40 '-0" 1 STORY/14 '-0" 8,500 464 SF 300 2 2/2 NR NO *NR 2022 CALIFORNIA ENERGY CODE, TITLE 24, PART 6
ENVELOPE COMPONENT REQUIRED PROVIDED
ROOFS U-0.034 U-0.034
WALLS ABOVE GRADE, MASS LIGHT U-0.170 ci U-0.170 ci
SLAB ON GRADE FLOORS U-0.039 U-0.039
ROOF - STEEP SLOPE U-0.25 U-0.25
ROOF - STEEP SLOPE U-0.80 U-0.80
AIR BARRIER REQ **NR, PROCESS BUILDING
DOORS - SWINGING U-0.70 U-0.70
DOORS - NONSWINGING U-1.45 U-1.45
FIXED FENESTRATION U-0.34 U-0.34
OPERABLE FENESTRATION U-0.46 U-0.46
SKYLIGHTS - PLASTIC DOME U-0.88 U-0.88
DOOR & HARDWARE SCHEDULE
DOOR
NUMBER
POSITION
INT/EXT
DOOR FRAME DETAILS UL
LABEL
LOUVER
SIZE
CARD
READER
PANIC
HARDWARE
HARDWARE
WIDTH HEIGHT THICK GROUP TYPE
(AJ103/TYP) MATL FINISH WIDTH HEIGHT DEPTH TYPE(AJ100/TYP) MATL FINISH HEAD
(AJ105/TYP)
JAMB
(AJ107/TYP)
SILL
(AJ109/TYP)
101-1 EXT 8'-0" 10' - 0" 3/4" C STEEL FACT FIN - - - - STEEL FACT FIN AJ123/TYP AJ123/TYP AJ123/TYP NR - - - - 101-2 EXT 8'-0" 10' - 0" 3/4" C STEEL FACT FIN - - - - STEEL FACT FIN AJ123/TYP AJ123/TYP AJ123/TYP NR - - - - 101-3 EXT PR 3'-2" 7' - 10" 1 3/4" F STEEL COATING 6'-8" 7'-4" 5 3/4" R STEEL COATING C C E NR NR REQ REQ HW-1 102-1 INT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C B NR NR NR NR HW-3 103-1 INT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C B NR NR NR REQ HW-4 103-2 EXT 10'-0" 10' - 0" 3/4" C STEEL FACT FIN - - - - STEEL FACT FIN AJ123/TYP AJ123/TYP AJ123/TYP NR - - - - 103-3 EXT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C E NR NR NR REQ HW-2 104-1 INT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C B NR NR NR REQ HW-5 104-2 EXT PR 3'-2" 7' - 10" 1 3/4" F STEEL COATING 6'-8" 7'-4" 5 3/4" R STEEL COATING C C E NR NR NR REQ HW-1
BUILDING CODE ANALYSIS
CAMPUS OAKS ASR WELL - REFERENCE DRAWING 13A01
THERMAL EMITTANCE
AGED SOLAR REFLECTANCE
.
ROOF - STEEP SLOPE
TABLE 140.3-B, CHAPTER 5, 2022 CALIFORNIA ENERGY CODE, TITLE 24, PART 6 **REFERENCE BUILDING ENERGY ANALYSIS COMPLIANCE REPORT NRCC-PRF PREPARED BY GABLE ASSOCIATES LLC *MACHINERY SPACES VISITED ONLY BY SERVICE PERSONNEL FOR MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH ADA ACCESSIBILITY (2022 CALIFORNIA TITLE 24).
ARCHITECTURAL SCHEDULES
CAMPUS OAKS ASR WELL - REFERENCE DRAWING 13A01
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASEMATL
NORTH EAST SOUTH WEST CEILING REMARKS
MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL INT CLR FINISH 101 PUMP ROOM CONC SEALER N/A CMU INT CLR CMU INT CLR CMU INT CLR CMU INT CLR GYP ±14'-0" PAINTED PAMP - QUANTITY TO BE DETERMINED 102 RESTROOM CONC SEALER WFRP CMU INT CLR/WFRP CMU INT CLR/WFRP CMU INT CLR/WFRP CMU INT CLR/WFRP GYP ±8'-8" PAINTED - 103 CHEMICAL ROOM CONC SEALER N/A CMU INT CLR CMU INT CLR CMU INT CLR CMU INT CLR GYP ±12'-6" PAINTED - 104 ELECTRICAL ROOM CONC SEALER N/A CMU INT CLR CMU INT CLR CMU INT CLR CMU INT CLR GYP ±14'-0" PAINTED - CAMPUS OAKS ASR WELL - REFERENCE DRAWING 13A01
H F I O
ROOM NAME CHEMICAL HAZARD CLASS CAS NO. MANUFACTURER STORAGE EXEMPT QUANTITY
IBC OCCUPANCY
CLASSIFICATION
NFPA RATING
REMARKS
HAZARDOUS MATERIAL INVENTORY STATEMENT TABLE
A
ELECTRICAL ROOM SODIUM FLUORIDE N/A 7681-49-4 TO BE DETERMINED TO BE DETERMINED YES F-1 CHEMICAL ROOM SODIUM HYPOCHLORITE 12.5% CORROSIVE 7681-52-9 TO BE DETERMINED 2 - 1,000 GALLON DAY TANK (MAX) YES F-1 2 3
0 0
1 0
-
-
. .
.
.
.
.
ELECTRICAL ROOM
. PER TABLE 307.1(2) OF THE 2019 CBC-1,000 GALLONS .
STORAGE PERMITTED, WAIVER SUBMITTED TO PERMIT
EXPANSION OF 2,000 GALLONS AT FULL BUILD OUT
CAMPUS OAKS ASR WELL - REFERENCE DRAWING 13A01
T
T
SF -
OL -
OLF -
SPR -
PUMP ROOM
101
1,174
4 300
NO
SF -
OL -
OLF -
SPR -
CHEMICAL ROOM
103
501
2 300
NO
27'-7" 24'-0"
SF -
OL -
OLF -
SPR -
RESTROOM
102
66 1
100
NO
32'-1" 26'-0"
34'-10"
65'-8"
SF -
OL -
OLF -
SPR -
ELECTRICAL
ROOM
104
460
2 300
NO
FX
FXE
FXE
FX
FX
EXIT, REFERENCE ELECTRICAL DRAWINGS FOR
LOCATION OF ILLUMINATED SIGNS
FIRE EXTINGUISHER, TYPE AS INDICATED,
REFERENCE DETAIL AN400/TYP AND SPECIFICATION
SECTION 10520
FIRE RATED WALL: HOUR AS # INDICATES
EGRESS ABBREVIATION & SYMBOLS LIST:
X'-X"
MEANS OF EGRESS PATH OF TRAVEL
TRAVEL DIRECTION
TOTAL TRAVEL DISTANCE
COMMON PATH TERMINATION
PATH START / MOST REMOTE POINT
SF: SQUARE FEET
OL: OCCUPANT LOAD
OLF: OCCUPANT LOAD FACTOR
SPR: AUTOMATIC SPRINKLER
FX
FXE
NR: NOT REQUIRED
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:38 PM
R:\d1341480\11843A1013A0801.rvt
13GA02
CAMPUS OAKS ASR WELL
EGRESS PLAN 27
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
PLAN A 1/4" = 1'-0"
EGRESS
T
T
FXE
FX
3' - 4" 6' - 8" 6' - 0" 2' - 8" 3' - 4" 3' - 4" 2' - 8" FX FX
90' - 0"
15' - 4" 8' - 0" 4' - 8"
28' - 0"
5' - 4" 8' - 0" 28' - 8" 6' - 8" 23' - 4" 10' - 0" 8' - 0" PUMP
ROOM
101
CHEMICAL
ROOM
103
ELECTRICAL
ROOM
104
FXE
104-2
102-1
101-1
101-2 101-3 103-2
1' - 4" 3' - 4" 8' - 0" 3' - 4" 1' - 0"
8' - 4"
RESTROOM
102
3 3
3 4 4
4 5 5
5 5
5 8
1 10
8' - 0"
2' - 0"
9 11
7 104-1
28' - 0"
90' - 0"
13A05
H
13A05 J
103-1
103-3
13A05
K
9' - 4" 3' - 4" 5' - 0"
12 6
1 1
12 2
2 10
8 8
11 14
14 14
13 2 14
15 13
GENERAL NOTES:
1. EXTERIOR FACE OF ALL CONCRETE MASONRY UNITS SHALL BE
FINISHED WITH WATER REPELLANT, REFERENCE SPECIFICATION
SECTION 07190.
2. FOR DOOR SCHEDULES AND ROOF FINISHES REFERENCE
SHEET 13GA01.
3. FOR EXTERIOR ENTRANCE PADS REFERENCE CIVIL DRAWINGS.
4. FOR RESTROOM ACCESSORY MOUNTING REFERENCE TYPICAL
DETAIL AN400/TYP AND SPECIFICATION SECTION 10810.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. OVERHEAD COILING DOOR, REFERENCE SPECIFICATION SECTION 08332
4. GUARD POST AT EACH SIDE OF COILING DOOR, REFERENCE CIVIL
DRAWINGS
5. FIRE EXTINGUISHER, REFERENCE SPECIFICATION SECTION 10520 AND AN400/TYP
6. FOR EQUIPMENT PADS AND GRATING, REFERENCE STRUCTURAL
DRAWINGS
7. FOR EQUIPMENT REQUIREMENTS, REFERENCE ELECTRICAL
DRAWINGS
8. FOR EQUIPMENT REQUIREMENTS, REFERENCE MECHANICAL
DRAWINGS
9. 24"D x 34"H METAL LABORATORY BASE CABINETS, MOLDED EPOXY WORK SURFACE WITH 4" BACK SPLASH, AND UNDERMOUNTED
MOLDED EPOXY SINK WITH HOT AND COLD WATER SUPPLY PER
PLUMBING
10. PREFABRICATED ACOUSTICAL METAL PANELS, REFERENCE
SPECIFICATION SECTION 09523
11. HOLLOW METAL DOOR AND FRAME, REFERENCE SPECIFICATION SECTION 08110
12. FOR CONCRETE SPLASH BLOCK, REFERENCE TYPICAL DETAIL AG229/TYP
13. FOR HVAC UNIT, LOUVERS, AND EQUIPMENT, REFERENCE
MECHANICAL DRAWINGS
14. MASONRY CONTROL JOINT, REFERENCE STRUCTURAL DRAWINGS
15. 2" X 4" WOOD STUDS WITH 5/8" GYPSUM WALL BOARD
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:23 PM
R:\d1341480\11843A1013A0801.rvt
13A01
CAMPUS OAKS ASR WELL
FLOOR PLAN 28
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
PLAN B 1/4" = 1'-0"
FLOOR
D 13A03
13A04
13A04
13A03
E
F
G
2' - 0" 28' - 0" 2' - 0"
32' - 0"
2' - 0" 90' - 0" 2' - 0"
94' - 0"
EXTENT OF WALL
BELOW
5 2
90' - 0"
2' - 0" 28' - 8" 28' - 8" 28' - 8" 2' - 0"
2' - 0" 25' - 8" 28' - 10" 29' - 6" 4' - 0" CL CL CL CL
CL CL CL CL
1 4
SLOPE
PER STRUCTURAL
SLOPE
PER STRUCTURAL
3 4' - 11" 7' - 0"
5' - 10" 7 '- 0"
M
13A05
L
13A05
SLOPE
PER STRUCTURAL
SLOPE
PER STRUCTURAL
GENERAL NOTES:
1. COORDINATE WITH STRUCTURAL DRAWINGS FOR SLOPE OF WOOD TRUSSES AND PLYWOOD DECKING REQUIREMENTS.
KEY NOTES:
1. STANDING SEAM METAL ROOF SYSTEM, REFERENCE SPECIFICATION SECTION 07415
2. ALUMINUM FASCIA, REFERENCE SPECIFICATION SECTION 07415
3. ROOF RIDGE, REFERENCE SPECIFICATION SECTION 07415
4. FOR GUTTER AND DOWNSPOUT, REFERENCE TYPICAL DETAIL
AG227/TYP
5. ROOF HATCH AND PREFABRICATED CURB, REFERENCE
SPECIFICATION SECTION 07722 AND AG170/TYP
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:25 PM
R:\d1341480\11843A1013A0801.rvt
13A02
CAMPUS OAKS ASR WELL
ROOF PLAN 29
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
PLAN C 1/4" = 1'-0"
ROOF
TOP OF FINISH FLOOR
0"
10' - 0"
14' - 0"
10' - 0"10' - 0" 1' - 4"
2 1
3 3 4
4 PER STRUCTURAL
12 11
TOP OF MASONRY
PER STRUCTURAL 14' - 0"
7' - 4" 2' - 8"
13 5
6 10
9 7
8 8' - 0" 2' - 0"8' - 0"
14 14
22' - 0" 46' - 0" 22' - 0" 1 14' - 0"
TOP OF FINISH FLOOR
PER STRUCTURAL
TOP OF MASONRY
PER STRUCTURAL
2 1
7 12
11 10' - 0" 1' - 4"
2' - 8" 2' - 0"
13 6
5 10
9 7' - 4"
8' - 0"
1 GENERAL NOTES:
1. EXTERIOR FACE OF ALL CONCRETE MASONRY UNITS SHALL BE
FINISHED WITH WATER REPELLANT, REFERENCE SPECIFICATION
SECTION 07190.
2. FOR DOOR SCHEDULES AND ROOF FINISHES, REFERENCE
SHEET 13GA01.
3. FOR EXTERIOR ENTRANCE PADS, REFERENCE CIVIL DRAWINGS.
4. COORDINATE WITH STRUCTURAL DRAWINGS SLOPE OF WOOD
TRUSSES AND PLYWOOD DECKING REQUIREMENTS.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. OVERHEAD COILING DOOR, REFERENCE SPECIFICATION SECTION 08332
4. GUARD POST AT EACH SIDE OF COILING DOOR, REFERENCE CIVIL
DRAWINGS
5. STANDING SEAM METAL ROOF SYSTEM, REFERENCE
SPECIFICATION SECTION 07415
6. FOR GUTTER AND DOWNSPOUT, REFERENCE TYPICAL DETAIL
AG227/TYP
7. FOR CONCRETE SPLASH BLOCK, REFERENCE TYPICAL DETAIL
AG229/TYP
8. ROOF HATCH PREFABRICATED CURB, REFERENCE SPECIFICATION SECTION 07722
9. ALUMINUM FASCIA, REFERENCE SPECIFICATION SECTION 07415
10. ALUMINUM SOFFIT, REFERENCE SPECIFICATION SECTION 07415
11. HOLLOW METAL DOOR AND FRAME, REFERENCE SPECIFICATION SECTION 08110
12. FOR EXTERIOR LIGHT FIXTURE, REFERENCE ELECTRICAL
DRAWINGS
13. FOR HVAC UNIT, LOUVERS, AND EQUIPMENT, REFERENCE
MECHANICAL DRAWINGS
14. MASONRY CONTROL JOINT, REFERENCE STRUCTURAL DRAWINGS #
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:29 PM
R:\d1341480\11843A1013A0801.rvt
13A03
CAMPUS OAKS ASR WELL
NORTH AND WEST ELEVATIONS 30
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
ELEVATION
1/4" = 1'-0" 13A02
E
WEST
SCALE:
ELEVATION
1/4" = 1'-0" 13A02
D
NORTH
TOP OF FINISH FLOOR
PER STRUCTURAL0"
14' - 0"
6 1
2 7
TOP OF MASONRY
PER STRUCTURAL 14' - 0"
10 9
11 1' - 4" 10' - 0"
5 8" 9' - 4"
12 12 2' - 0" 2' - 0"
22' - 0" 46' - 0" 21' - 6"
1 TOP OF FINISH FLOOR
PER STRUCTURAL0"
10' - 0"
5 6
7 2
1 4 3
TOP OF MASONRY
PER STRUCTURAL 14' - 0"
14' - 0"
10 9
8 1' - 4" 10' - 0"
1 GENERAL NOTES:
1. EXTERIOR FACE OF ALL CONCRETE MASONRY UNITS SHALL BE
FINISHED WITH WATER REPELLANT, REFERENCE SPECIFICATION
SECTION 07190.
2. FOR DOOR SCHEDULES AND ROOF FINISHES, REFERENCE
SHEET 13GA01.
3. FOR EXTERIOR ENTRANCE PADS, REFERENCE CIVIL DRAWINGS.
4. COORDINATE WITH STRUCTURAL DRAWINGS SLOPE OF WOOD
TRUSSES AND PLYWOOD DECKING REQUIREMENTS.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. OVERHEAD COILING DOOR, REFERENCE SPECIFICATION SECTION 08332
4. GUARD POST AT EACH SIDE OF COILING DOOR, REFERENCE CIVIL
DRAWINGS
5. STANDING SEAM METAL ROOF SYSTEM, REFERENCE
SPECIFICATION SECTION 07415
6. FOR GUTTER AND DOWNSPOUT, REFERENCE TYPICAL DETAIL
AG227/TYP
7. FOR CONCRETE SPLASH BLOCK, REFERENCE TYPICAL DETAIL
AG229/TYP
8. ROOF HATCH AND PREFABRICATED CURB, REFERENCE
SPECIFICATION SECTION 07722
9. ALUMINUM FASCIA, REFERENCE SPECIFICATION SECTION 07415
10. ALUMINUM SOFFIT, REFERENCE SPECIFICATION SECTION 07415
11. FOR HVAC UNIT, LOUVERS, AND EQUIPMENT, REFERENCE
MECHANICAL DRAWINGS
12. MASONRY CONTROL JOINT, REFERENCE STRUCTURAL DRAWINGS #
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:30 PM
R:\d1341480\11843A1013A0801.rvt
13A04
CAMPUS OAKS ASR WELL
SOUTH AND EAST ELEVATIONS 31
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
ELEVATION
1/4" = 1'-0" 13A02
G
EAST
SCALE:
ELEVATION
1/4" = 1'-0" 13A02
F
SOUTH
4' - 0" 5' - 4"
4 3
7 2
3 4
1 1 1
Level 1
0' - 0"
Lower Plan
130' 130' -10 13/16" - 10 3/4"
Level 1
0' - 0"
Lower Plan
130' - 10 13/16"
5 5' - 4" 4' - 0"
4 4
1 5
6 3
1 2
9' - 4"
Level 1
0' - 0"
Lower Plan
130' 130' -10 13/16" - 10 3/4"
Level 1
0' - 0"
Lower Plan
130' - 10 13/16"
5 6
5 4 3
1 2
1 2' - 6" 1' - 10" 2' - 10"
6 GENERAL NOTES:
1. FOR RESTROOM ACCESSORY MOUNTING, REFERENCE TYPICAL
DETAIL AN100/TYP.
2. FOR LAB CABINETS REFER TO SPECIFICATION SECTION.
3. FOR RESTROOM ACCESSORIES, REFERENCE SPECIFICATION
SECTION 10810.
4. FOR PLUMBING SYSTEMS, REFERENCE SPECIFICATION
SECTION 15400.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. 4'-0" H MIN. FRP WALL SYSTEM, SMOOTH FINISH, LIGHT GRAY S490N COLOR AS MANUFACTURED BY MARLITE OR EQUAL. SYSTEM SHALL
BE INSTALLED AT THE BASE OF ALL THE RESTROOM WALLS
4. WOOD STUDS PER STRUCTURAL, 5/8" TYPE X FIRE RATED GYPSUM
WALLBOARD EACH SIDE
5. 2" X 4" WOOD STUDS WITH 5/8" GYPSUM WALL BOARD
6. 2" X 6" FIRE RETARDANT WOOD STUDS AT 12 0.C. MAX WITH 5/8"
TYPE X GYPSUM BOARD, TEXTURED AND PAINTED PER
SPECIFICATIONS
#
1. FLOOR MOUNTED WATER CLOSET
2. SURFACE MOUNTED ADA LAVATORY
3. ADA MIRROR
4. GRAB BARS
5. SURFACE MOUNTED TOILET PAPER HOLDER
6. SURFACE MOUNTED PAPER TOWEL DISPENSER AND RECEPTACLE
7. SURFACE MOUNTED LIQUID SOAP DISPENSER
1. 1" THICK MOLDED EPOXY WORK SURFACE
2. 4"H MOLDED EPOXY BACK SPLASH
3. 18"W x 24"D x 34"H METAL LABORATORY BASE CABINET WITH FOUR
DRAWERS
4. 30"W x 24"D x 24"H METAL LABORATORY BASE CABINET WITH
UNDERMOUNTED MOLDED EPOXY SINK, REFERENCE
SPECIFICATION SECTION 15400 FOR FAUCET WITH HOT AND COLD
WATER SUPPLY
5. 48"W x 24"D x 34"H DOUBLE DOOR METAL LABORATORY BASE
CABINET
6. 48"W x 14"D x 30"H DOUBLE DOOR METAL LABORATORY WALL
MOUNTED CABINET WITH TWO SHELVES
# RESTROOM AND ANALYSIS AREA SCHEDULE
# CABINETRY SCHEDULE
STANDING SEAM ROOF SYSTEM
NAILABLE BASE AS REQUIRED
BY MANUFACTURER
INSULATION
U - .034
REFERENCE STRUCTURAL
DRAWINGS FOR SHEATHING
GUTTER
FASCIA, PER ROOFING
MANUFACTURER
FINISH SOFFIT PANEL
FLUSH JOINT,
PER ROOFING MFR
DOWNSPOUT
CONCRETE MASONRY UNIT
STRUCTURAL TRUSSES,
REFER TO STRUCTURAL
DRAWINGS
5/8" GYPSUM WALLBOARD
2X WOOD BLOCKING
WOOD TRIM WITH
CAULKING
2X WOOD BLOCKING
FOR SOFFIT SUPPORT
STANDARD CMU
FASCIA BEYOND
WOOD NAILER
STANDING SEAM METAL ROOF SYSTEM
NAILABLE BASE AS REQUIRED
BY MANUFACTURER
INSULATION
U - 0.34
REFERENCE STRUCTURAL
DRAWINGS FOR SHEATHING
FASCIA, PER ROOFING MFR
SOFFIT PANEL FLUSH JOINT,
PER ROOFING MFR
CONCRETE MASONRY UNIT
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:30:32 PM
R:\d1341480\11843A1013A0801.rvt
13A05
CAMPUS OAKS ASR WELL
INTERIOR ELEVATIONS 32
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
ELEVATION
1/2" = 1'-0" 13A01
H
SCALE:
ELEVATION
1/2" = 1'-0" 13A01
J
SCALE:
ELEVATION
1/2" = 1'-0" 13A01
K
SCALE:
SECTION
3/4" = 1'-0" 13A02
L
SCALE:
SECTION
3/4" = 1'-0" 13A02
M
SCHEDULE ABBREVIATION LIST:
B:
ci:
CMU:
CONC:
EXPO:
F-1:
FACT FIN:
GYP:
HW:
MATL:
MTL DECK
N/A
NR:
PAMP:
PR:
REQ:
SEALER:
U-FACTOR:
WDECK:
WFRP:
INT CLR:
BUSINESS GROUP (2022, TITLE 24)
CONTINUOUS INSULATION
INTEGRALLY COLORED CONCRETE MASONRY UNIT, REFERENCE
SPECIFICATION SECTION 04220
CONCRETE
EXPOSED MATERIAL
FACTORY INDUSTRIAL GROUP, MODERATE HAZARD OCCUPANCY
(2022, TITLE 24)
FACTORY FINISH
GYPSUM WALL BOARD, REFERENCE SPECIFICATION SECTION
09250
HARDWARE GROUP, REFERENCE SPECIFICATION SECTION 08710
MATERIAL
METAL DECK PER STRUCTURAL DESIGN
NOT APPLICABLE
NOT REQUIRED
PERFORATED ACOUSTICAL METAL PANELS. SYSTEM SHALL EXTEND TO THE UNDERSIDE OF GYP CEILING. REFERENCE SPECIFICATION SECTION 09523
PAIR
REQUIRED
FLOOR COATING, REFERENCE SPECIFICATION SECTION 09960
THERMAL TRANSMITTANCE, IS THE COEFFICIENT OF HEAT
TRANSMISSION (AIR TO AIR) THROUGH A BUILDING COMPONENT OR
ASSEMBLY, EQUAL TO THE TIME RATE OF HEAT FLOW PER UNIT
AREA AND UNIT TEMPERATURE DIFFERENCE BETWEEN THE WARM
SIDE AND COLD SIDE AIR FILMS (2022, TITLE 24)
WOOD DECK PER STRUCTURAL DESIGN
STANDARD FRP WALL SYSTEM, SMOOTH FINISH, LIGHT GRAY S490N AS MANUFACTURED BY MARLITE OR EQUAL. FRP SHALL BE
INSTALLED AT THE PERIMETER (INTERIOR FACE) OF THE FOUR
RESTROOM WALLS, THE FRP WALL SYSTEM SHALL BE 4'H FROM
FINISH FLOOR.
INTEGRAL COLOR
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:29 PM
R:\d1341480\11843A1019A0801.rvt
19GA01
MISTY WOODS ASR WELL
BUILDING CODE ANALYSIS, AND SCHEDULES 33
ARCHITECTURAL
JCA
FVG
MEH
2022 CALIFORNIA BUILDING CODE, TITLE 24, PART 2, VOL.1 & 2 BUILDING NAME, ROOM #, & ROOM WITHIN
STRUCTURE CONST.
TYPE
OCCUPANCY
CLASSIFICATION
ALLOW.
STORIES/HEIGHT
ACTUAL
STORIES/HEIGHT
ALLOW.
AREA (EA.
FLOOR)
ACTUAL
FLOOR AREA
(EA. FLOOR)
OCCUPANT
LOAD
FACTOR
ACTUAL
OCCUPANT
LOAD
NO. OF EXITS
REQ/PROVIDED
OCCUPANCY
SEPARATION
FIRE
SUPPRESSION
ACCESSIBILITY
ROOM # ROOM NAME
101 PUMP ROOM V-B F-1 1 STORIES/40 '-0" 1 STORY/14 '-0" 8,500 1,123 SF 300 4 1/1 NR NO *NR 102 RESTROOM V-B B 1 STORIES/40 '-0" 1 STORY/14 '-0" 9,000 65 SF 100 1 1/1 NR NO R 103 CHEMICAL ROOM V-B F-1 1 STORIES/40 '-0" 1 STORY/14 '-0" 8,500 501 SF 300 2 1/2 NR NO *NR 104 ELECTRICAL ROOM V-B F-1 1 STORIES/40 '-0" 1 STORY/14 '-0" 8,500 464 SF 300 2 2/2 NR NO *NR 2022 CALIFORNIA ENERGY CODE, TITLE 24, PART 6
ENVELOPE COMPONENT REQUIRED PROVIDED
ROOFS U-0.034 U-0.034
WALLS ABOVE GRADE, MASS LIGHT U-0.170 ci U-0.170 ci
SLAB ON GRADE FLOORS U-0.039 U-0.039
ROOF - STEEP SLOPE U-0.25 U-0.25
ROOF - STEEP SLOPE U-0.80 U-0.80
AIR BARRIER REQ **NR, PROCESS BUILDING
DOORS - SWINGING U-0.70 U-0.70
DOORS - NONSWINGING U-1.45 U-1.45
FIXED FENESTRATION U-0.34 U-0.34
OPERABLE FENESTRATION U-0.46 U-0.46
SKYLIGHTS - PLASTIC DOME U-0.88 U-0.88
DOOR & HARDWARE SCHEDULE
DOOR
NUMBER
POSITION
INT/EXT
DOOR FRAME DETAILS UL
LABEL
LOUVER
SIZE
CARD
READER
PANIC
HARDWARE
HARDWARE
WIDTH HEIGHT THICK GROUP TYPE
(AJ103/TYP) MATL FINISH WIDTH HEIGHT DEPTH TYPE(AJ100/TYP) MATL FINISH HEAD
(AJ105/TYP)
JAMB
(AJ107/TYP)
SILL
(AJ109/TYP)
101-1 EXT 8'-0" 10' - 0" 3/4" C STEEL FACT FIN - - - - STEEL FACT FIN AJ123/TYP AJ123/TYP AJ123/TYP NR - - - - 101-2 EXT 8'-0" 10' - 0" 3/4" C STEEL FACT FIN - - - - STEEL FACT FIN AJ123/TYP AJ123/TYP AJ123/TYP NR - - - - 101-3 EXT PR 3'-2" 7' - 10" 1 3/4" F STEEL COATING 6'-8" 7'-4" 5 3/4" R STEEL COATING C C E NR NR REQ REQ HW-1 102-1 INT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C B NR NR NR NR HW-3 103-1 INT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C B NR NR NR REQ HW-4 103-2 EXT 10'-0" 10' - 0" 3/4" C STEEL FACT FIN - - - - STEEL FACT FIN AJ123/TYP AJ123/TYP AJ123/TYP NR - - - - 103-3 EXT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C E NR NR NR REQ HW-2 104-1 INT 3'-0" 7' - 2" 1 3/4" F STEEL COATING 3'-4" 7'-4" 5 3/4" R STEEL COATING C C B NR NR NR REQ HW-5 104-2 EXT PR 3'-2" 7' - 10" 1 3/4" F STEEL COATING 6'-8" 7'-4" 5 3/4" R STEEL COATING C C E NR NR NR REQ HW-1
BUILDING CODE ANALYSIS
MISTY WOODS ASR WELL - REFERENCE DRAWING 19A01
THERMAL EMITTANCE
AGED SOLAR REFLECTANCE
.
ROOF - STEEP SLOPE
TABLE 140.3-B, CHAPTER 5, 2022 CALIFORNIA ENERGY CODE, TITLE 24, PART 6 **REFERENCE BUILDING ENERGY ANALYSIS COMPLIANCE REPORT NRCC-PRF PREPARED BY GABLE ASSOCIATES LLC *MACHINERY SPACES VISITED ONLY BY SERVICE PERSONNEL FOR MAINTENANCE, REPAIR OR OCCASIONAL MONITORING OF EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH ADA ACCESSIBILITY (2022 CALIFORNIA TITLE 24).
ARCHITECTURAL SCHEDULES
MISTY WOODS ASR WELL - REFERENCE DRAWING 19A01
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASEMATL
NORTH EAST SOUTH WEST CEILING REMARKS
MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL FINISH MATL INT CLR FINISH 101 PUMP ROOM CONC SEALER N/A CMU INT CLR CMU INT CLR CMU INT CLR CMU INT CLR GYP ±14'-0" PAINTED PAMP - QUANTITY TO BE
DETERMINED
102 RESTROOM CONC SEALER WFRP CMU INT CLR/WFRP CMU INT CLR/WFRP CMU INT CLR/WFRP CMU INT CLR/WFRP GYP ±8'-8" PAINTED - 103 CHEMICAL ROOM CONC SEALER N/A CMU INT CLR CMU INT CLR CMU INT CLR CMU INT CLR GYP ±12'-6" PAINTED - 104 ELECTRICAL ROOM CONC SEALER N/A CMU INT CLR CMU INT CLR CMU INT CLR CMU INT CLR GYP ±14'-0" PAINTED - MISTY WOODS ASR WELL - REFERENCE DRAWING 19A01
H F I O
ROOM NAME CHEMICAL HAZARD CLASS CAS NO. MANUFACTURER STORAGE EXEMPT QUANTITY
IBC OCCUPANCY
CLASSIFICATION
NFPA RATING
REMARKS
HAZARDOUS MATERIAL INVENTORY STATEMENT TABLE
A
ELECTRICAL ROOM SODIUM FLUORIDE N/A 7681-49-4 TO BE DETERMINED TO BE DETERMINED YES F-1 CHEMICAL ROOM SODIUM HYPOCHLORITE 12.5% CORROSIVE 7681-52-9 TO BE DETERMINED 2 - 1,000 GALLON DAY TANK (MAX) YES F-1 2 3
0 0
1 0
-
-
. .
.
.
.
.
ELECTRICAL ROOM
. PER TABLE 307.1(2) OF THE 2019 CBC-1,000 GALLONS .
STORAGE PERMITTED, WAIVER SUBMITTED TO PERMIT
EXPANSION OF 2,000 GALLONS AT FULL BUILD OUT
MISTY WOODS ASR WELL - REFERENCE DRAWING 19A01
T
T
SF -
OL -
OLF -
SPR -
PUMP ROOM
101
1,174
4 300
NO
SF -
OL -
OLF -
SPR -
CHEMICAL ROOM
103
501
2 300
NO
27'-7" 24'-0"
SF -
OL -
OLF -
SPR -
RESTROOM
102
66 1
100
NO
32'-1" 26'-0"
34'-10"
65'-8"
SF -
OL -
OLF -
SPR -
ELECTRICAL
ROOM
104
460
2 300
NO
FX
FXE
FXE
FX
FX
EXIT, REFERENCE ELECTRICAL DRAWINGS FOR
LOCATION OF ILLUMINATED SIGNS
FIRE EXTINGUISHER, TYPE AS INDICATED,
REFERENCE DETAIL AN400/TYP AND SPECIFICATION
SECTION 10520
FIRE RATED WALL: HOUR AS # INDICATES
EGRESS ABBREVIATION & SYMBOLS LIST:
X'-X"
MEANS OF EGRESS PATH OF TRAVEL
TRAVEL DIRECTION
TOTAL TRAVEL DISTANCE
COMMON PATH TERMINATION
PATH START / MOST REMOTE POINT
SF: SQUARE FEET
OL: OCCUPANT LOAD
OLF: OCCUPANT LOAD FACTOR
SPR: AUTOMATIC SPRINKLER
FX
FXE
NR: NOT REQUIRED
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:34 PM
R:\d1341480\11843A1019A0801.rvt
19GA02
MISTY WOODS ASR WELL
EGRESS PLAN 34
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
PLAN A 1/4" = 1'-0"
EGRESS
T
T
FXE
FX
3' - 4" 6' - 8" 6' - 0" 2' - 8" 3' - 4" 3' - 4" 2' - 8" FX FX
90' - 0"
15' - 4" 8' - 0" 4' - 8"
28' - 0"
5' - 4" 8' - 0" 28' - 8" 6' - 8" 23' - 4" 10' - 0" 8' - 0" PUMP
ROOM
101
CHEMICAL
ROOM
103
ELECTRICAL
ROOM
104
FXE
104-2
102-1
101-1
101-2 101-3 103-2
1' - 4" 3' - 4" 8' - 0" 3' - 4" 1' - 0"
8' - 4"
RESTROOM
102
3 3
3 4 4
4 5 5
5 5
5 8
1 10
8' - 0"
2' - 0"
9 11
7 104-1
28' - 0"
90' - 0"
19A05
H
19A05 J
103-1
103-3
19A05
K
9' - 4" 3' - 4" 5' - 0"
12 6
1 1
12 2
2 13
14 14 14
14 8
8 11
2 15
13 GENERAL NOTES:
1. EXTERIOR FACE OF ALL CONCRETE MASONRY UNITS SHALL BE
FINISHED WITH WATER REPELLANT, REFERENCE SPECIFICATION
SECTION 07190.
2. FOR DOOR SCHEDULES AND ROOF FINISHES REFERENCE
SHEET 19GA01.
3. FOR EXTERIOR ENTRANCE PADS REFERENCE CIVIL DRAWINGS.
4. FOR RESTROOM ACCESSORY MOUNTING REFERENCE TYPICAL
DETAIL AN400/TYP AND SPECIFICATION SECTION 10810.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. OVERHEAD COILING DOOR, REFERENCE SPECIFICATION SECTION 08332
4. GUARD POST AT EACH SIDE OF COILING DOOR, REFERENCE CIVIL
DRAWINGS
5. FIRE EXTINGUISHER, REFERENCE SPECIFICATION SECTION 10520 AND AN400/TYP
6. FOR EQUIPMENT PADS AND GRATING, REFERENCE STRUCTURAL
DRAWINGS
7. FOR EQUIPMENT REQUIREMENTS, REFERENCE ELECTRICAL
DRAWINGS
8. FOR EQUIPMENT REQUIREMENTS, REFERENCE MECHANICAL
DRAWINGS
9. 24"D x 34"H METAL LABORATORY BASE CABINETS, MOLDED EPOXY WORK SURFACE WITH 4" BACK SPLASH, AND UNDERMOUNTED
MOLDED EPOXY SINK WITH HOT AND COLD WATER SUPPLY PER
PLUMBING
10. PREFABRICATED ACOUSTICAL METAL PANELS, REFERENCE
SPECIFICATION SECTION 09523
11. HOLLOW METAL DOOR AND FRAME, REFERENCE SPECIFICATION SECTION 08110
12. FOR CONCRETE SPLASH BLOCK, REFERENCE TYPICAL DETAIL AG229/TYP
13. FOR HVAC UNIT, LOUVERS, AND EQUIPMENT, REFERENCE
MECHANICAL DRAWINGS
14. MASONRY CONTROL JOINT, REFERENCE STRUCTURAL DRAWINGS
15. 2" X 4" WOOD STUDS WITH 5/8" GYPSUM WALL BOARD
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:19 PM
R:\d1341480\11843A1019A0801.rvt
19A01
MISTY WOODS ASR WELL
FLOOR PLAN 35
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
PLAN B 1/4" = 1'-0"
FLOOR
D 19A03
19A04
19A04
19A03
E
F
G
2' - 0" 28' - 0" 2' - 0"
32' - 0"
2' - 0" 90' - 0" 2' - 0"
94' - 0"
EXTENT OF WALL
BELOW
5 2
90' - 0"
2' - 0" 28' - 8" 28' - 8" 28' - 8" 2' - 0"
2' - 0" 25' - 8" 28' - 10" 29' - 6" 4' - 0" CL CL CL CL
CL CL CL CL
1 4
SLOPE
PER STRUCTURAL
SLOPE
PER STRUCTURAL
3 4' - 11" 7' - 0"
5' - 10" 7 '- 0"
M
19A05
L
19A05
SLOPE
PER STRUCTURAL
SLOPE
PER STRUCTURAL
GENERAL NOTES:
1. COORDINATE WITH STRUCTURAL DRAWINGS FOR SLOPE OF WOOD TRUSSES AND PLYWOOD DECKING REQUIREMENTS.
KEY NOTES:
1. STANDING SEAM METAL ROOF SYSTEM, REFERENCE SPECIFICATION SECTION 07415
2. ALUMINUM FASCIA, REFERENCE SPECIFICATION SECTION 07415
3. ROOF RIDGE, REFERENCE SPECIFICATION SECTION 07415
4. FOR GUTTER AND DOWNSPOUT, REFERENCE TYPICAL DETAIL
AG227/TYP
5. ROOF HATCH AND PREFABRICATED CURB, REFERENCE
SPECIFICATION SECTION 07722 AND AG170/TYP
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:21 PM
R:\d1341480\11843A1019A0801.rvt
19A02
MISTY WOODS ASR WELL
ROOF PLAN 36
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
PLAN C 1/4" = 1'-0"
ROOF
TOP OF FINISH FLOOR
0"
10' - 0"
14' - 0"
10' - 0"10' - 0" 1' - 4"
2 1 3
3 4
4 PER STRUCTURAL
12 11
TOP OF MASONRY
PER STRUCTURAL 14' - 0"
7' - 4" 2' - 8"
13 5
6 10
9 7
8 8' - 0" 2' - 0"8' - 0"
14 14
22' - 0" 46' - 0" 22' - 0"
1 14' - 0"
TOP OF FINISH FLOOR
PER STRUCTURAL
TOP OF MASONRY
PER STRUCTURAL
2 1
7 12
11 10' - 0" 1' - 4"
2' - 8" 2' - 0"
13 6
5 10
9 7' - 4"
1 8' - 0"
GENERAL NOTES:
1. EXTERIOR FACE OF ALL CONCRETE MASONRY UNITS SHALL BE
FINISHED WITH WATER REPELLANT, REFERENCE SPECIFICATION
SECTION 07190.
2. FOR DOOR SCHEDULES AND ROOF FINISHES, REFERENCE
SHEET 19GA01.
3. FOR EXTERIOR ENTRANCE PADS, REFERENCE CIVIL DRAWINGS.
4. COORDINATE WITH STRUCTURAL DRAWINGS SLOPE OF WOOD
TRUSSES AND PLYWOOD DECKING REQUIREMENTS.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. OVERHEAD COILING DOOR, REFERENCE SPECIFICATION SECTION 08332
4. GUARD POST AT EACH SIDE OF COILING DOOR, REFERENCE CIVIL
DRAWINGS
5. STANDING SEAM METAL ROOF SYSTEM, REFERENCE
SPECIFICATION SECTION 07415
6. FOR GUTTER AND DOWNSPOUT, REFERENCE TYPICAL DETAIL
AG227/TYP
7. FOR CONCRETE SPLASH BLOCK, REFERENCE TYPICAL DETAIL
AG229/TYP
8. ROOF HATCH AND PREFABRICATED CURB, REFERENCE
SPECIFICATION SECTION 07722
9. ALUMINUM FASCIA, REFERENCE SPECIFICATION SECTION 07415
10. ALUMINUM SOFFIT, REFERENCE SPECIFICATION SECTION 07415
11. HOLLOW METAL DOOR AND FRAME, REFERENCE SPECIFICATION SECTION 08110
12. FOR EXTERIOR LIGHT FIXTURE, REFERENCE ELECTRICAL
DRAWINGS
13. FOR HVAC UNIT, LOUVERS, AND EQUIPMENT, REFERENCE
MECHANICAL DRAWINGS
14. MASONRY CONTROL JOINT, REFERENCE STRUCTURAL DRAWINGS #
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:25 PM
R:\d1341480\11843A1019A0801.rvt
19A03
MISTY WOODS ASR WELL
NORTH AND EAST ELEVATIONS 37
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
ELEVATION
1/4" = 1'-0" 19A02
E
NORTHEAST
SCALE:
ELEVATION
1/4" = 1'-0" 19A02
D
SOUTHEAST
TOP OF FINISH FLOOR
PER STRUCTURAL0"
14' - 0"
6 1
2 7
TOP OF MASONRY
PER STRUCTURAL 14' - 0"
10 9
11 1' - 4" 10' - 0"
5 8" 9' - 4"
12 12
22' - 0" 46' - 0" 22' - 0" 2' - 0" 2' - 0"
1 TOP OF FINISH FLOOR
PER STRUCTURAL0"
10' - 0"
5 6
7 2
1 4 3
TOP OF MASONRY
PER STRUCTURAL 14' - 0"
14' - 0"
10 9
8 1' - 4" 10' - 0"
1 GENERAL NOTES:
1. EXTERIOR FACE OF ALL CONCRETE MASONRY UNITS SHALL BE
FINISHED WITH WATER REPELLANT, REFERENCE SPECIFICATION
SECTION 07190.
2. FOR DOOR SCHEDULES AND ROOF FINISHES, REFERENCE
SHEET 19GA01.
3. FOR EXTERIOR ENTRANCE PADS, REFERENCE CIVIL DRAWINGS.
4. COORDINATE WITH STRUCTURAL DRAWINGS SLOPE OF WOOD
TRUSSES AND PLYWOOD DECKING REQUIREMENTS.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. OVERHEAD COILING DOOR, REFERENCE SPECIFICATION SECTION 08332
4. GUARD POST AT EACH SIDE OF COILING DOOR, REFERENCE CIVIL
DRAWINGS
5. STANDING SEAM METAL ROOF SYSTEM, REFERENCE
SPECIFICATION SECTION 07415
6. FOR GUTTER AND DOWNSPOUT, REFERENCE TYPICAL DETAIL
AG227/TYP
7. FOR CONCRETE SPLASH BLOCK, REFERENCE TYPICAL DETAIL
AG229/TYP
8. ROOF HATCH AND PREFABRICATED CURB, REFERENCE
SPECIFICATION SECTION 07722
9. ALUMINUM FASCIA, REFERENCE SPECIFICATION SECTION 07415
10. ALUMINUM SOFFIT, REFERENCE SPECIFICATION SECTION 07415
11. FOR HVAC UNIT, LOUVERS, AND EQUIPMENT, REFERENCE
MECHANICAL DRAWINGS
12. MASONRY CONTROL JOINT, REFERENCE STRUCTURAL DRAWINGS #
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:27 PM
R:\d1341480\11843A1019A0801.rvt
19A04
MISTY WOODS ASR WELL
SOUTH AND WEST ELEVATIONS 38
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
ELEVATION
1/4" = 1'-0" 19A02
G
SOUTHWEST
SCALE:
ELEVATION
1/4" = 1'-0" 19A02
F
NORTHWEST
4' - 0" 5' - 4"
4 3
7 2
3 4
1 1 1
Lower Plan
130'-10 13/16" 131' - 6"
Level 1
0' - 0"
Lower Plan
100'
Level 1
0'
Lower Plan
131' 6"
5 5' - 4" 4' - 0"
4 4
1 5
6 3
1 2
9' - 4"
Lower Plan
130'-10 13/16" 131' - 6"
Level 1
0' - 0"
Lower Plan
100'
Level 1
0'
Lower Plan
131' 6"
5 6
5 4 3
1 2
1 2' - 6" 1' - 10" 2' - 10"
Lower Plan
131' - 6"
Top Of Wall
145' - 6"
Lower Plan
130'-10 13/16"
Top Of Wall
144'-10 13/16"
Lower Plan
100' - 0"
Top Of Wall
114' - 0"
Level 1
0' - 0"
Lower Plan
131' 6"
Top Of Wall
144' - 10"
6 GENERAL NOTES:
1. FOR RESTROOM ACCESSORY MOUNTING, REFERENCE TYPICAL
DETAIL AN100/TYP.
2. FOR LAB CABINETS REFER TO SPECIFICATION SECTION.
3. FOR RESTROOM ACCESSORIES, REFERENCE SPECIFICATION
SECTION 10810.
4. FOR PLUMBING SYSTEMS, REFERENCE SPECIFICATION
SECTION 15400.
KEY NOTES:
1. 12" X 8" X 16" INTEGRALLY COLORED SMOOTH-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
2. 12" X 8" X 16" INTEGRALLY COLORED SPLIT-FACE CONCRETE
MASONRY UNITS, COLOR AS SELECTED BY OWNER
3. 4'-0" H MIN. FRP WALL SYSTEM, SMOOTH FINISH, LIGHT GRAY S490N COLOR AS MANUFACTURED BY MARLITE OR EQUAL. SYSTEM SHALL
BE INSTALLED AT THE BASE OF ALL THE RESTROOM WALLS
4. WOOD STUDS PER STRUCTURALLY, 5/8" TYPE X FIRE RATED
GYPSUM WALLBOARD EACH SIDE
5. 2" X 4" WOOD STUDS WITH 5/8" GYPSUM WALL BOARD
6. 2" X 6" FIRE RETARDANT WOOD STUDS AT 12 O.C. MAX WITH 5/8"
TYPE X GYPSUM BOARD, TEXTURED AND PAINTED PER
SPECIFICATIONS
#
1. FLOOR MOUNTED WATER CLOSET
2. SURFACE MOUNTED ADA LAVATORY
3. ADA MIRROR
4. GRAB BARS
5. SURFACE MOUNTED TOILET PAPER HOLDER
6. SURFACE MOUNTED PAPER TOWEL DISPENSER AND RECEPTACLE
7. SURFACE MOUNTED LIQUID SOAP DISPENSER
1. 1" THICK MOLDED EPOXY WORK SURFACE
2. 4"H MOLDED EPOXY BACK SPLASH
3. 18"W x 24"D x 34"H METAL LABORATORY BASE CABINET WITH FOUR
DRAWERS
4. 30"W x 24"D x 24"H METAL LABORATORY BASE CABINET WITH
UNDERMOUNTED MOLDED EPOXY SINK, REFERENCE
SPECIFICATION SECTION 15400 FOR FAUCET WITH HOT AND COLD
WATER SUPPLY
5. 48"W x 24"D x 34"H DOUBLE DOOR METAL LABORATORY BASE
CABINET
6. 48"W x 14"D x 30"H DOUBLE DOOR METAL LABORATORY WALL
MOUNTED CABINET WITH TWO SHELVES
# RESTROOM AND ANALYSIS AREA SCHEDULE
# CABINETRY SCHEDULE
STANDING SEAM ROOF SYSTEM
NAILABLE BASE AS REQUIRED
BY MANUFACTURER
REFERENCE STRUCTURAL
DRAWINGS FOR SHEATHING
GUTTER
FASCIA, PER ROOFING
MANUFACTURER
FINISH SOFFIT PANEL
FLUSH JOINT,
PER ROOFING MFR
DOWNSPOUT
CONCRETE MASONRY UNIT
STRUCTURAL TRUSSES,
REFER TO STRUCTURAL
DRAWINGS
5/8" GYPSUM WALLBOARD
2X WOOD BLOCKING
WOOD TRIM WITH
CAULKING
2X WOOD BLOCKING
FOR SOFFIT SUPPORT
INSULATION
U - .034
STANDARD CMU
FASCIA BEYOND
STANDING SEAM METAL ROOF SYSTEM
NAILABLE BASE AS REQUIRED
BY MANUFACTURER
INSULATION
U - .034
REFERENCE STRUCTURAL
DRAWINGS FOR SHEATHING
FASCIA, PER ROOFING MFR
SOFFIT PANEL FLUSH JOINT,
PER ROOFING MFR
CONCRETE MASONRY UNIT
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 2:41:28 PM
R:\d1341480\11843A1019A0801.rvt
19A05
MISTY WOODS ASR WELL
INTERIOR ELEVATIONS 39
ARCHITECTURAL
JCA
FVG
MEH
SCALE:
ELEVATION
1/2" = 1'-0" 19A01
H
SCALE:
ELEVATION
1/2" = 1'-0" 19A01
J
SCALE:
ELEVATION
1/2" = 1'-0" 19A01
K
SCALE:
SECTION
3/4" = 1'-0" 19A02
L
SCALE:
SECTION
3/4" = 1'-0" 19A02
M
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 53219
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20243:04:51PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:11843A1000GS01.dgn
GENERAL NOTES:
TYPICAL STRUCTURAL MATERIALS:
CONSTRUCTION:
STRUCTURAL SYMBOLS:
CURED TO THEIR MINIMUM SPECIFIED 28-DAY COMPRESSIVE STRENGTH.OF THE WALL ARE IN PLACE, ARE COMPLETE, AND (IN THE CASE OF CONCRETE) HAVE
2.DO NOT PLACE BACKFILL AGAINST WALLS UNTIL STRUCTURES SUPPORTING THE TOP PREPARED, BEFORE PROCEEDING WITH FOUNDATION CONSTRUCTION.OBTAIN ENGINEER’S OBSERVATION OF SUBGRADE SURFACES, AS EXPOSED AND AS
1.EXPOSE AND PREPARE SUBGRADE AS SHOWN ON THE DRAWINGS AND SPECIFIED. EXCAVATION AND BACKFILLING:
SPECIAL INSPECTION:
REINFORCING STEEL (FOR CONCRETE AND MASONRY):CONCRETE:MASONRY:STRUCTURAL STEEL:
STRUCTURAL ABBREVIATIONS:DEFERRED DESIGN SUBMITTALS
STRUCTURAL DESIGN CRITERIA - GENERAL:
THE DRAWINGS.
CONFORM TO THE FOLLOWING REQUIREMENTS UNLESS OTHERWISE INDICATED ON ITS MINIMUM SPECIFIED 28-DAY COMPRESSIVE STRENGTH.STRUCTURE ABOVE IS COMPLETE AND (IN THE CASE OF CONCRETE) HAS CURED TO ARE COMPLETE, PROVIDE BRACING FOR WALLS. KEEP BRACING IN PLACE UNTIL THE
3. WHERE BACKFILL MUST BE PLACED AGAINST WALLS BEFORE STRUCTURES ABOVE FOR DETAILED AND LOCATION-SPECIFIC REQUIREMENTS.
2. SEE PROJECT SPECIFICATIONS AND NOTES ON DRAWINGS OF SPECIFIC STRUCTURES OTHERWISE INDICATED ON THE DRAWINGS.
1.MATERIALS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS UNLESS
DISCREPANCIES
OPENINGS.
8.SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZES OF DOOR AND WINDOW D.SEE MECHANICAL DRAWINGS FOR EQUIPMENT PADS AND PIPE SUPPORTS.
AND ASSOCIATED STRUCTURAL REQUIREMENTS.
C.SEE MECHANICAL DRAWINGS FOR DETAILS OF PIPE PENETRATIONS, PIPE SUPPORTS, DIAMETER ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS.
B.IN GENERAL, OPENINGS, EMBEDMENTS, AND PENETRATIONS LESS THAN 12 INCHES IN ITEMS AND EQUIPMENT FURNISHED.
A.CONFIRM SIZE AND LOCATIONS OF OPENINGS, PENETRATIONS AND EMBEDMENT FOR STRUCTURES.CONDUITS, AND OTHER ITEMS THAT ARE EMBEDDED INTO OR PASS THROUGH
7.DRAWINGS PREPARED BY OTHER DISCIPLINES INCLUDE OPENINGS, ANCHORS, PIPES, TO WHICH SITE COORDINATES REFER ARE SHOWN ON THE STRUCTURAL PLANS.
6.SEE CIVIL DRAWINGS FOR STRUCTURE COORDINATES. POINTS ON THE STRUCTURES ORIENTATION REQUIRED AT THAT STRUCTURE.CONCRETE) IS GENERALLY ARBITRARY. SEE DRAWINGS OF EACH STRUCTURE FOR REINFORCEMENT (WHETHER “LINES” OR “DOTS”ARE CLOSER TO THE FACE OF THE B.IN STRUCTURAL TYPICAL DETAILS, ORIENTATION OF BARS IN EACH MAT OF TITLES, EVEN WHEN NOT SPECIFICALLY REFERENCED ON THE DRAWINGS.
A. TYPICAL DETAILS ARE INTENDED TO APPLY AT LOCATIONS DESCRIBED BY THEIR
5.TYPICAL DETAILS ARE INCLUDED ON THE “TS” DRAWINGS.
B. SIZES AND LOCATIONS OF EQUIPMENT PADS FOR EQUIPMENT SELECTED.A. DIMENSIONS AND WEIGHTS FOR EQUIPMENT SELECTED.FOLLOWING BEFORE PREPARATION AND SUBMITTAL OF SHOP DRAWINGS:DIMENSIONS, AND INFORMATION SHOWN ON THESE DRAWINGS. CONFIRM THE IMMEDIATELY OF BETWEEN EXISTING CONDITIONS AND
4.VERIFY DIMENSIONS AND CONDITIONS BEFORE BEGINNING WORK. ADVISE ENGINEER SHOWS CONSTRUCTION AT AND BELOW ELEVATION 110.)
C. PLANS ARE TREATED AS HORIZONTAL SECTIONS. (I.E.: “PLAN AT ELEVATION 110” B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES.A. SCREENED LINE WORK INDICATES EXISTING CONDITIONS.
3.PRESENTATION CONVENTIONS FOR STRUCTURAL DRAWINGS:
INDICATED IN THE GENERAL NOTES AND TYPICAL DETAILS.
2.UNLESS DETAILED, SPECIFIED, OR INDICATED OTHERWISE, CONSTRUCTION SHALL BE AS DISCIPLINES AND WITH THE SPECIFICATIONS.
1.USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH PROJECT DRAWINGS BY OTHER C. WELDS - SHIELDED METAL ARC PROCESS USING E70-XX ELECTRODES.
ASTM F 1554, GRADE 36 GALVANIZED.ASTM F 593, STAINLESS TYPE 316 (304)ANCHOR BOLTS WITH HEX FORGED HEAD.
B. BOLTS - STEEL TO CONCRETE OR MASONRY:
WASHERS.ASTM F 3125 GRADE A325 HIGH-STRENGTH BOLTS, WITH LOAD INDICATOR A. BOLTS - STEEL TO-STEEL:
2. CONNECTIONS:
SQUARE AND RECTANGULAR: ASTM A 500, GRADE B (Fy = 46 KSI)ROUND: ASTM A 500, GRADE B (Fy = 42 KSI) E. HOLLOW STRUCTURAL SECTIONS:D. PIPES: ASTM A 53, GRADE B (Fy = 35 KSI)C. PLATES AND BARS: ASTM A 36 (Fy = 36 KSI)B. SHAPES S, ST, M, MT, HP, C, MC, L: ASTM A 36 (Fy = 36 KSI)A. SHAPES W, WT: ASTM A 992 (Fy = 50 KSI)
1. SECTIONS
EH
BRACING, AND BALANCING.THEIR DESIGN STRENGTH, PROTECT STRUCTURES AS REQUIRED BY SHORING, FACILITIES. UNTIL CONSTRUCTION IS COMPLETE AND MEMBERS HAVE ACHIEVED STRUCTURES HAVE BEEN DESIGNED FOR OPERATING LOADS ON COMPLETED
9. CONSTRUCTION LOADS:
2. WELDED WIRE FABRIC: ASTM A 1064.
B. WHERE INDICATED ON THE DRAWINGS: ASTM A 706.A. TYPICAL: ASTM A 615, GRADE 60.
1. DEFORMED BARS:
D.ELECTRICAL DUCT ENCASEMENT: “CLASS CE” f’c = 2500 PSI.C.PIPE ENCASEMENT: “CLASS CE” f’c = 2500 PSI.B.FILL AND THRUST BLOCKS: “CLASS C” f’c = 2500 PSI.A.STRUCTURES: “CLASS A”OR “CLASS B” f’c = 4000 PSI.
2.MINIMUM SPECIFIED CONCRETE COMPRESSIVE STRENGTH, f’c (AT 28 DAYS UNO).1.NORMAL DENSITY. 1)SOLID GROUTED: f’m = 1500 PSI.
D.MINIMUM SPECIFIED COMPRESSIVE STRENGTH, f’m (AT 28 DAYS).C.GROUT: ASTM C 476. MINIMUM 28-DAY COMPRESSIVE STRENGTH = 2000 PSI.B.MORTAR: ASTM C 270, MINIMUM 28-DAY COMPRESSIVE STRENGTH = 1800 PSI.A.UNITS: ASTM C 90, NORMAL WEIGHT.
1.CONCRETE MASONRY
6.DIVISION 6 WOOD, PLASTICS AND COMPOSITES.
C.COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION.
2) SIDE CONNECTIONS BETWEEN ADJACENT SHEETS.1) CONNECTIONS TO SUPPORTS.
B.STEEL DECKING.
4) ANCHORS - POST-INSTALLED MECHANICAL AND ADHESIVE.3) ANCHORS - CAST-IN AND BUILT-IN ANCHOR BOLTS.2) MEMBER SIZES/TYPES.1) MEMBER LOCATIONS.
A.GENERAL ALL METALS:
5.DIVISION 5 METALS
G.PROTECTION AND CURING PROCEDURES.F.GROUT AND GROUTING.E.MORTAR AND JOINTS.D.ANCHORS: BUILT-IN AND POST-INSTALLED.C.REINFORCING STEEL.B.MEMBER SIZES.A.LOCATIONS.
4.DIVISION 4 MASONRY
G.PRECAST CONCRETE.F.PROTECTION AND CURING PROCEDURES.E.CONCRETE MIX AND PLACEMENT.D.ANCHORS: CAST-IN AND POST-INSTALLED.C.REINFORCING STEEL.B.FORMWORK AND MEMBER SIZES.A.LOCATIONS.
3.DIVISION 3 CONCRETE:
D.FILL AND BACKFILL.C.PREPARATION OF SOILS/SURFACES SUPPORTING CONSTRUCTION.B.ADEQUACY OF EXPOSED SURFACE TO PROVIDE REQUIRED SUPPORT.A.EXCAVATION DEPTH.
2.DIVISION 2 SITE CONSTRUCTION (EARTHWORK)
AND CONSTRUCTION. SEE SPECIFICATION SECTION 01455 FOR DETAILS.
1.SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING STRUCTURAL MATERIALS (AWS) A2.4.
2.WELDING: SYMBOLS: IN ACCORDANCE WITH AMERICAN WELDING SOCIETY FOR DEFINITION OF MATERIALS SHADING PATTERNS.
1. SEE DRAWING G03 FOR KEY TO DRAWING TITLES AND SECTION CUTS, AND BAR SIZE)# NUMBER (REINFORCINGT.O. TOP OFO.F. OUTSIDE FACEI.F. INSIDE FACEEF EACH FACE PL PLATEBO BOTTOM OF L ANGLEREINFORCEMENT: OTHER:ABBREVIATIONS HAVE THE MEANINGS LISTED.WHEN USED ON THE STRUCTURAL DRAWINGS, THE FOLLOWING
4. ABBREVIATIONS FOR STRUCTURAL DRAWINGS:
THE ALUMINUM ASSOCIATION’S ALUMINUM DESIGN MANUAL, CURRENT EDITION.
B. ALUMINUM: ABBREVIATIONS AND DESIGNATIONS ARE IN ACCORDANCE WITH MANUAL, CURRENT EDITION.AMERICAN INSTITUTE OF STEEL CONSTRUCTION’S STEEL CONSTRUCTION A. STEEL: ABBREVIATIONS AND DESIGNATIONS ARE IN ACCORDANCE WITH THE
3. STRUCTURAL MEMBERS:
PROJECT SPECIFICATIONS.
2. ABBREVIATIONS FOR NAMES OF TECHNICAL GROUPS MAY BE FOUND IN THE 1. SEE DRAWING G02 FOR GENERAL LIST OF ABBREVIATIONS USED ON DRAWINGS.
A. 06174 SHOP-FABRICATED WOOD TRUSSES.
1. DIVISION 6 WOOD AND PLASTICS.DEFERRED DESIGN SUBMITTALS FOR THIS PROJECT INCLUDE:SUBSEQUENTLY SUBMITTED TO THE BUILDING OFFICIAL.THAT ARE TO BE REVIEWED BY THE REGISTERED DESIGN PROFESSIONAL AND OF THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF PERMIT APPLICATION, AND AS DEFINED IN THE BUILDING CODE, DEFERRED DESIGN SUBMITTALS ARE PORTIONS 40603000.30
53804500.45
B. TYPE 304L: E304L-15 ELECTRODES.A. TYPE 316L: E316L-15 ELECTRODES.
4. WELDED CONNECTIONS:
C. TYPE 304/304L: ASTM F 593, GRADE B8, CLASS 1, HEAVY HEX.B. TYPE 316/316L: ASTM F 593, GRADE B8M, CLASS 1, HEAVY HEX.A. MATCH ALLOY OF THE STRUCTURAL MEMBERS CONNECTED.
3. BOLTED CONNECTIONS - BOLTS AND ANCHOR BOLTS:2. SECTIONS: SHAPES AND BARS: ASTM A 276.1. ANSI TYPE 316/316L EXCEPT WHERE TYPE 304/304L IS INDICATED ON THE DRAWINGS.STAINLESS STEEL:
40603000.30
53804500.45
ABE
RYW
EQ
STRUCTURAL 00GS01
GENERAL NOTES
( * 5% DAMPED)E. DESIGN SPECTRAL RESPONSE ACCELERATIONS:* Sds =0.43 g Sd1 =0.32D. MAXIMUM CONSIDERED ACCELERATIONS:* Sms =0.645 g Sm1 = 0.48C. SITE COEFFICIENTS: Fa = 1.443 Fv = 2.154B. MAPPED SPECTRAL RESPONSE ACCELERATIONS:Ss = 0.447 g S1 = 0.223 gA. SITE CLASS: D. 0.2 SECOND *1.0 SECOND
7. MISTY WOODS EARTHQUAKE DESIGN DATA:
C. BASIC WIND SPEED (3 SEC GUST, 33 FEET ABOVE GROUND): 105 MPH.B. WIND-BORNE DEBRIS REGION: NOA. SPECIAL WIND REGION: NO
6. WIND DESIGN DATA FOR MISTY WOODS AND CAMPUS OAKS:5. FLUID PRESSURE LOADS: 63 PSF/FT (UNO).
D. EQUIPMENT LOADS: SEE PLANS.C. ROOF LIVE LOAD: SEE PLANS (25 PSF MINIMUM).B. GRATING AND CHECKERED PLATE: 100 PSF (UNO).A. FLOOR LIVE LOAD: SEE PLANS.
4. LIVE LOADS: (REDUCTIONS NOT USED)3. DEAD LOADS: CALCULATED FOR STRUCTURE SELF-WEIGHT.2. STRUCTURE RISK CATEGORY: SEE PLANS FOR EACH STRUCTURE.
B. LOCAL AMENDMENTS: CITY OF ROSEVILLE.A. 2022 CALIFORNIA BUILDING CODE (“CBC 2022”) WITH ASCE 7-16.
1. BUILDING CODE:THESE OVERALL CRITERIA FOR THE SITE.SEE DRAWINGS OF INDIVIDUAL STRUCTURES FOR SPECIFIC DESIGN CRITERIA BASED ON ( * 5% DAMPED)E. DESIGN SPECTRAL RESPONSE ACCELERATIONS:* Sds =0.43 g Sd1 =NULLD. MAXIMUM CONSIDERED ACCELERATIONS:* Sms =0.645 g Sm1 = NULLC. SITE COEFFICIENTS: Fa = 1.443 Fv = NULLB. MAPPED SPECTRAL RESPONSE ACCELERATIONS:Ss = 0.447 g S1 = 0.224 gA. SITE CLASS: D. 0.2 SECOND *1.0 SECOND
8. CAMPUS OAKS EARTHQUAKE DESIGN DATA:
FOR MISTY WOODS:GEOTECHNICAL REPORT / FOUNDATION DESIGN CRITERIA D. GROUNDWATER EL 0.00'.
SLIDING COEFFICIENT OF FRICTION: PASSIVE (PSF/FT): AT REST (PSF/FT): ACTIVE (PSF/FT):
STATIC SEISMIC
SURCHARGE: EQUIVALENT TO 2 FEET OF SOIL ABOVE FINISHED GRADE.C. LATERAL EARTH PRESSURE (UNO): B. FROST DEPTH: 0A. NET ALLOWABLE BEARING PRESSURE SEE PLANS.
INVESTIGATION REPORT.2. FOUNDATION DESIGNS ARE BASED ON RECOMMENDATIONS IN THE GEOTECHNICAL REPORT NO: 17340.000.000 DATED: FEBRUARY 27, 2023.PREPARED BY: ENGEO.
ASR WELL (WELL 19).
TITLE: AQUIFER STORAGE RECOVERY WELL AND PUMP STATION MISTY WOODS
1. GEOTECHNICAL INVESTIGATION REPORT:
FOR CAMPUS OAKS:GEOTECHNICAL REPORT / FOUNDATION DESIGN CRITERIA D. GROUNDWATER EL 19.00'.
SLIDING COEFFICIENT OF FRICTION: PASSIVE (PSF/FT): AT REST (PSF/FT):
ACTIVE (PSF/FT):
STATIC SEISMIC
SURCHARGE: EQUIVALENT TO 2 FEET OF SOIL ABOVE FINISHED GRADE.C. LATERAL EARTH PRESSURE (UNO): B. FROST DEPTH: 0A. NET ALLOWABLE BEARING PRESSURE SEE PLANS.
INVESTIGATION REPORT.2. FOUNDATION DESIGNS ARE BASED ON RECOMMENDATIONS IN THE GEOTECHNICAL REPORT NO: 17340.000.000 DATED: AUGUST 30, 2021.PREPARED BY: ENGEO.TITLE: AQUIFER STORAGE RECOVERY WELL AND PUMP STATION CAMPUS OAKS WELL.
1. GEOTECHNICAL INVESTIGATION REPORT:
CONSTRUCTION. SEE SPECIFICATION SECTION 01455 FOR DETAILS.
1. STRUCTURAL OBSERVATION IS REQUIRED DURING AND AT SPECIFIC STAGES OF STRUCTURAL OBSERVATION:
40 rwelch
ANCHORS.LOCATIONS OF REINFORCEMENT IN MEMBERS BEFORE DRILLING HOLES FOR ANCHORS. USE NON-DESTRUCTIVE TESTING EQUIPMENT TO IDENTIFY B.DO NOT CUT, DAMAGE, OR INTERRUPT EXISTING REINFORCEMENT TO INSTALL EVALUATION REPORT AND MANUFACTURER’S INSTRUCTIONS.
A.INSTALL IN FULL COMPLIANCE WITH ACCEPTED BUILDING CODE
4.POST-INSTALLED ANCHORS IN CONCRETE AND MASONRY:
ALUMINUM SURFACES AS SPECIFIED IN SECTION 09960.
B.WHERE ALUMINUM IS IN CONTACT WITH MASONRY OR CONCRETE, COAT ISOLATING SLEEVES AND WASHERS AS SPECIFIED IN SECTION 05190.AND STAINLESS STEEL, OR ALUMINUM AND STEEL) PROVIDE A.AT BOLTED CONNECTIONS THAT INCLUDE DIFFERENT METALS (E.G.: STEEL
3.INTERFACE BETWEEN MATERIALS:
BEING JOINED, AND FULL LENGTH OF THE JOINT.
A.FILLET WELDS: PER AWS CODE BASED ON THE THICKNESS OF THE MATERIALS
2.WELDED:
EDGE OF A PLATE OR STRUCTURAL ELEMENT.
C.WITH A DISTANCE OF AT LEAST 1 1/2 INCHES FROM CENTER OF BOLT TO ANY CENTER.
B.HAVING A MINIMUM OF 2 BOLTS, SPACED NOT CLOSER THAN 3 INCHES ON A.MADE USING 3/4-INCH DIAMETER BOLTS.
1.BOLTED:STEEL, STAINLESS STEEL, AND ALUMINUM - CONNECTIONS:
A.FULLY GROUTED.
4.GROUTING:
DRAWINGS OR ACCEPTED IN ADVANCE BY THE ENGINEER.
3.WELDING OF REINFORCING IS NOT PERMITTED UNLESS DETAILED ON THE B.AT OPENINGS AS INDICATED IN SF220/TYP.A.AT CORNERS AND JUNCTIONS AS INDICATED IN SF230/TYP.
2.PROVIDE REINFORCING:1.SEE SF002/TYP FOR MASONRY NOTES, INCLUDING LAP SPLICE LENGTHS.MASONRY: B. HOUSEKEEPING PAD FOR ELECTRICAL EQUIPMENT SEE SD702/TYP. A. EQUIPMENT PAD SEE SD512/TYP.8. CONCRETE PADS7.FINISH CONCRETE AS SPECIFIED IN SECTION 03366.
AND EMBEDMENTS.
6.MAINTAIN MINIMUM 3 INCHES CLEAR CONCRETE COVER BETWEEN REINFORCING DRAWINGS OR ACCEPTED IN ADVANCE BY THE ENGINEER.
5.WELDING OF REINFORCING IS NOT PERMITTED UNLESS DETAILED ON THE A.AT OPENINGS - AS INDICATED IN SC012/TYP.
4.PROVIDE REINFORCING:
SPECIFICATION 03102 FOR CHAMFERS.
3.PROVIDE CHAMFER AT EXPOSED EDGES OF CAST-IN-PLACE CONCRETE. SEE ACCEPTANCE BY THE ENGINEER BEFORE FORM LAYOUT.
2.SUBMIT LOCATIONS OF CONSTRUCTION JOINTS NOT SHOWN ON THE DRAWINGS FOR LENGTH REQUIREMENTS FOR REINFORCING.
1.SEE SC001/TYP FOR CONCRETE NOTES, INCLUDING CLEAR COVER AND LAP SPLICE CONCRETE:
MATERIAL.
B.COVER PLATE AND ITS SEATS OR SUPPORTS SHALL BE OF THE SAME OTHERWISE NOTED.
A.ALUMINUM WITH TYPE 316 STAINLESS STEEL FASTENERS, UNLESS
2.COVER PLATES:
FASTEN GRATING TO SUPPORTS AS INDICATED IN SR601/TYP.
C.UNLESS INDICATED ON THE DRAWINGS AS “REMOVABLE GRATING”, SECURELY B.GRATING AND ITS SEATS OR SUPPORTS SHALL BE OF THE SAME MATERIAL.
OTHERWISE NOTED.
A.ALUMINUM WITH TYPE 316 STAINLESS STEEL FASTENERS, UNLESS
1.GRATING:METAL FABRICATIONS:
D
13S03
E
13S03
CHEMICAL ROOM
ELECTRICAL ROOM
PUMP ROOM
RESTROOM
12" FULLY
GROUTED CMU
WALL (TYP)
5' - 4" 8' - 0" 28' - 8" 6' - 8"
90' - 0"
4' - 8" 8' - 0"
28' - 0"
34' - 4" 11' - 4" 44' - 4"
3' - 4" 6' - 8" 3' - 4" 8' - 8" 3' - 4" 2' - 8"
13' - 4" 14' - 8"
2' - 8"
51' - 4" 38' - 8"
3'-0" SQ SUMP
8' - 4"
17' - 0"
CHEMICAL TANK
PAD
SEE DWG 13M09 FOR WELLHEAD
AND PUMP CONCRETE PEDESTAL
DETAILS. 3'-6" MINIMUM PEDESTAL
DIAMETER. FINAL DIMENSIONS PER
APPROVED PUMP SEISMIC
ANCHORAGE REQUIREMENTS.
4' - 8"
1' - 0"
31' - 2"
9' - 6"
F
13S03
22' - 0" 22' - 0" 24' - 0" 22' - 0" CJ/MCJ CJ CJ/MCJ
TYP
SD702 (TYP) TYP
EM118
HPT 130.90
HPT 130.90
HPT 130.90
HPT 130.90 HPT 130.90
HPT
130.90
LPT 130.87
TOC 130.90
(2) #6 ADD BARS T&B (TYP)
TYP
TYPICAL WALL SF220
DOWELS
TYP
SF230 SINGLE DOWEL IN CORNERS
& INTERSECTIONS
TYP
SD382
TYP
SF230
8" (TYP)
JAMB BAR
DOWELS (TYP)
W/O
WSTP
1' - 0"
(TYP)
1' - 0"
9' - 4"
(TYP)
TYPICAL WALL DOWELS
SEE DETAIL 2/09S04
HPT 130.90
LPT 130.83
#6 DIAGONAL BARS
T&B (TYP)
2' - 6" 4' - 11" 5' - 6" 4' - 3"
8"
2' - 0"
7"
1' - 2"
8' - 6"
1' - 2"
8"
1' - 2"
5' - 6" 16' - 7 1/2"
8"
1' - 0"
TYP
SF220
RIM 130.90
INV 129.90
1'-0" WIDE
TRENCH
MIN 0.7%
SLOPE
RIM 130.75
INV 129.90
RIM 130.75
INV 129.50
RIM 130.90
INV 129.90
MAX 2%SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
HPT 130.90 HPT 130.90
H
13S04
1' - 0"
3' - 4" 8' - 0" 3' - 4"
1' - 4"
14' - 8" 2' - 8" 22' - 8" 1' - 4"
3' - 4" 2' - 8"
29' - 4" 2' - 8"
2' - 8" 29' - 4"
5' - 0" 3' - 4" 9' - 4"
2' - 0" MCJ
20' - 8" 10' - 0" 8' - 0"
STAINLESS
STEEL COVER
HPT 130.90 ZURN #ZF806-HDS-BDE 6"
WIDE TRENCH
RIM 130.70
26' - 11"
THICKNESS = 12"
TOC 130.90
1/8"/FT
SLOPE
TYP
SD503
TYP
1" SD382
EJ
RIM 130.80 RIM 130.80
(TYP)
TYP
SD512 (SIM)
W/O BASE PLATE
TYP
SC012
INV 129.71
INV 129.16
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 1:10:55 PM
R:\d1341486\11843A1013S801.rvt
13S01
CAMPUS OAKS ASR WELL
FOUNDATION PLAN 41
STRUCTURAL
EQ
RYW
ABE
SCALE:
PLAN A 1/4" = 1'-0"
1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
2. SEE DRAWING 13S02 FOR STRUCTURE DESIGN CRITERIA.
3. SEE DRAWING 13S03 FOR STRUCTURE FOUNDATION DESIGN
CRITERIA.
GENERAL NOTES:
2 '-3"9'-9"4'-0"9'-9"2'-3"
2'-0"OVERHANG(TYP)
2'-0" 43 PRE-ENGINEERED STANDARD TRUSSES @ 2'-0" = 86'-0" 2'-0" 2'-0" OVERHANG (TYP) 32'-0"
No. 53219
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:54:27AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 13S02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
ABE
RYW
STRUCTURAL
ROOF PLANS
11843A1013S002.dgn
(TYP)
INTERIOR PANEL EDGES
BLOCKING
SHAPED RIDGE
(TYP)
SHEATHING (TYP)
PLYWOOD ROOF
STANDARD 4'x8'
SLOPE
4V:12H
SLOPE
(TYP)
OF BUILDING
G
5 C
ROOF RIDGE L
(TYP)
STANDARD TRUSS
PRE-ENGINEERED
(TYP)
EDGE NAILING
INTERIOR PANEL
NAILING (TYP)
BOUNDARY
DIAPHRAGM
(TYP)
WITH BLOCKING
ALIGN PANEL EDGE
13S05
13S05
B
11843A1013S100
3/16" = 1'-0"
ROOF FRAMING PLAN
C
11843A1013S101
3/16" = 1'-0"
ROOF SHEATHING PLAN
F
13S03
E
13S03
D
13S03
G
13S05
D
13S03
E
13S03
F
13S03
G
13S05
(TYP) G
13S05
HATCH DESIGN REQUIREMENTS
SEE MECHANICAL DRAWINGS FOR
GENERAL NOTES:
REMAIN PERMANENTLY A PART OF TRUSS SYSTEM.BRACING SHALL NOT BE REMOVED AND SHALLRECOMMENDATIONS DURING TRUSS ERECTION. LATERALPER PRE-ENGINEERED TRUSS MANUFACTURER'S
3. ALL TRUSSES SHALL BE LATERALLY BRACED FOR STABILITY 2. TRUSS LOADING SEE SR620 / TYP.
WIDTH CHORD AND WEB MEMBERS.
1. ALL ROOF TRUSSES SHALL HAVE DUAL 1.5" NOMINAL
III TRUSS NOTES:
K
13S04 BELOW ROOF FRAMING
BATHROOM WALLS
4V:12H
# KEY NOTES:
(TYP)
2x OUT LOOKER 2x BLOCKING (TYP)
(TYP)
LOOKER
2x OUT
(TYP)
2x BLOCKING
ARCHITECTURAL DWGS (TYP)
EAVE FASCIA BOARD. SEE
(TYP)
2x BLOCKING
(TYP)
2x OUT LOOKER
1 STRAP 8 FOOT LONG (TYP)SIMPSON STRONG TIE CS16 COIL
NAILING (TYP)
BOUNDARY
DIAPHRAGM
2. STAGGER NAILS AT ADJOINING PANEL EDGES.
10d NAILS AT 6" SPACING.
C. INTERIOR PANEL:
10d NAILS AT 4" SPACING.BOUNDARIES:
B. NORTH AND SOUTH DIAPHRAGM
10d NAILS AT 6" SPACING.
A. EAST AND WEST DIAPHRAGM BOUNDARIES:
1. NAILING SCHEDULE:SHEATHING:
I ROOF SHEATHING: 15/32" STRUCTURAL 1 C-D
BLOCKED WITH FULL DEPTH BLOCKING.
2. ALL EDGES OF PLYWOOD SHEATHING SHALL BE
TRUSS TOP.
1. PROVIDE 2X FULL DEPTH BLOCKING BETWEEN
II FRAMING NOTES:
1. PROVIDE SIMPSON STRONG-TIE CS16 COIL STRAP AT OPENING.
CAMPUS OAKS ASR WELL
EQ
(TYP AROUND OPENING)
DOUBLE TRUSS
(TYP)
ARCHITECTURAL DWGS AND SOFFIT. SEE
RAKE FASCIA BOARD
42 TOP PLATE AT SPLICE LOCATIONS.
6. PROVIDE SIMPSON STRONG-TIE MSTA 21 STRAP AT EACH SIDE OF TOGETHER WITH 10d NAILS @6".PRESSURE TREATED. STAGGER STITCH NAIL TOP PLATES
5. (2) 2x10 TOP PLATE FOR 12x8x16 CMU. TOP PLATES SHALL BE FOR CLARITY.
4. ROOF UNDERLAYMENT AND STANDING SEAM ROOFING NOT SHOWN SIZE AND LOCATION.
3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR PENETRATION B. IMPORTANCE FACTOR, Iw: 1.0.A. EXPOSURE FACTOR: C.
4. WIND DESIGN CRITERIA:
E. SEISMIC RESPONSE COEFFICIENT, Cs: 0.1335.D. RISK CATEGORY: IV.C. IMPORTANCE FACTOR: 1.5.B. ANALYSIS PROCEDURE: ASCE 7-16 § 12.8.1. SPECIAL REINFORCED MASONRY SHEAR WALL, R: 5.A. BASIC SEISMIC FORCE RESISTING SYSTEM:
3. SEISMIC DESIGN CRITERIA:
C. SLAB AND EQUIPMENT: SELF WEIGHT. GROUTED: 133 PSF.B. WALL: NORMAL WEIGHT 12" CMU, SOLID A. ROOF: 25 PSF.
2. DESIGN DEAD LOAD:
SINGLE WHEEL POINT LOAD.C. FLOOR: 200 PSF DISTRIBUTED LOAD, 8,000 LBS B. GRATING: 100 PSF.A. ROOF: 20 PSF.
1. DESIGN LIVE LOAD:
2. STRUCTURAL DESIGN CRITERIA.1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES. rwelch
PUMP
PEDESTAL
1 13S04
1 2
(TYP)
(TYP)
TOC VARIES,
SEE PLAN
2x OUT LOOKER (TYP)
PRE-ENGINEERED
STANDARD TRUSS (TYP)
2x BLOCKING (TYP)
2 13S04
(SIM)
(TYP)
TYP
SF220
12 4
2 13S04
TOC VARIES,
SEE PLAN
TYP
(TYP) SF220
(2) #5 ADD BARS IN
ADDITION TO TYPICAL
WALL HORIZONTAL
REINFORCING 4'-0" LONG
TRUSS NOT SHOWN
FOR CLARITY
T.O.W. 144.90
12 4
3 13S04
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 1:10:56 PM
R:\d1341486\11843A1013S801.rvt
13S03
CAMPUS OAKS ASR WELL
SECTIONS AND DETAILS 1 43
STRUCTURAL
EQ
RYW
ABE
SCALE:
SECTION
1/4" = 1'-0" 13S01
D
SCALE:
SECTION
1/4" = 1'-0" 13S01
E
SCALE:
SECTION
1/4" = 1'-0" 13S01
F
KEY NOTES:
1. AGGREGATE BASE PER SPECIFICATION 02050 AND 02300.
2. SUBGRADE PREP:
A. SCARIFY TO A DEPTH OF AT LEAST 10 INCHES.
B. MOISTURE CONDITION SOIL TO AT LEAST 3 PERCENT ABOVE
OPTIMUM MOISTURE CONTENT.
C. COMPACT SUBGRADE TO AT LEAST 90 PERCENT RELATIVE
COMPACTION.
#
1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
2. NET ALLOWABLE BEARING PRESSURES:
A. DEAD LOAD ONLY: 2,500 PSF.
B. DEAD + LIVE LOAD: 2,500 PSF.
C. TOTAL (INCLUDING WIND OR SEISMIC): 3,333 PSF.
GENERAL NOTES:
#6@12" EW T&B (TYP)
#6@12" EW T&B
#6@12" EW EF
(TYP)
(TYP)
LAP SPLICE
1' - 0"
(TYP)
1' - 0"
(TYP)
1' - 0"
1 1
1 1
TYP
SD102
CLSM FILL. AT
CONTRACTOR'S
OPTION
1' - 6"
#5@16" EW EF (TYP
ALL CMU WALLS)SPLICE LAP
TOC VARIES,
SEE PLAN
#5 DOWELS
(TYP)
(2) #5 CONT
T.O.W. 144.90
SPLICE
LAP
#6@12" x 5'-0" CENTERED ON TRENCH
2' - 0"
1 1
2' - 8"
(TYP)
LAP SPLICE
#6@12" EW T&B (TYP)
VARIES
#6 BENT BAR @12"
CENTERED ON TRENCH
#6@12" x 5'-0"
CENTERED ON
TRENCH
1 1
1 1
6' - 4"
(TYP)
LAP SPLICE
10"
#6@12" x 4'-0"
CENTERED ON
TRENCH
2' - 0" 9"
T.O.W. 140.23
TOC 130.90
TYP
SF220
RESTROOM CEILING PLAN
J
-
2X6 (TYP)
2X6 (TYP)
(4) EQ SPACES = 9' - 4"
(3) EQ SPACES = 7' - 4"
SIMPSON STRONG TIE
HTT4 W/ (18) #10 x 1 1/2" SD
SCREWS (TYP)
SIMPSON STRONG TIE JB26
TOP MOUNTED HANGER (TYP)
TYP
SF062 5/8"Ø W/ 6" EMBED
(TYP)
SIMPSON STRONG TIE 18"
LONG CMSTC16 COIL STRAP
(TYP @ EACH JOIST)
SIMPSON STRONG TIE
A35 CLIP
SIMPSON STRONG TIE LU26
FACE MOUNTED HANGER (TYP)
15/32 STRUCTURAL 1 C-D SHEATHING.
10d @ 6" NAIL SPACING
2x6 PRESSURE
TREATED LEDGER
TYP
SF062 5/8"Ø W/ 6" EMBED
T.O.W. 140.23
TOP OF WALL (BEYOND)
2x6 DF BEAM (TYP)
PLYWOOD SHEATHING
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 1:10:58 PM
R:\d1341486\11843A1013S801.rvt
13S04
CAMPUS OAKS ASR WELL
SECTIONS AND DETAILS 2 44
STRUCTURAL
EQ
RYW
ABE
SCALE:
DETAIL
1/2" = 1'-0" 13S03
1 SCALE:
DETAIL
3/8" = 1'-0" 13S03
2 SCALE:
DETAIL
1/2" = 1'-0" 13S03
3 SCALE:
SECTION
3/8" = 1'-0" 13S01
H
SCALE:
PLAN K 1/2" = 1'-0"
SCALE:
J
-
SECTION
1 1/2" = 1'-0"
1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
2. BATHROOM ROOF LOADING:
A. LIVE LOAD: 15 PSF
B. DEAD LOAD: 20 PSF
3. PROVIDE 3/4" BEVEL OR CHAMFER (REFER TO SECTION 03102).
4. SEE KEY NOTES ON DRAWING 13S03 FOR BUILDING
FOUNDATION SUBGRADE MATERIALS AND PREPARATION.
GENERAL NOTES:
4'-0"
4'-0"
2'-1"
2'-1"
4'-0"
4'-0"
1/8"GAP
2'-0"
CMU
53/4"
2'-0"
2'-0"
2'-0"OC(TYP)
(TYP)LOOKER2x OUT-
(TYP)STANDARD TRUSSPRE-ENGINEERED
A35 CLIP (TYP)SIMPSON STRONG-TIE
BLOCKING (TYP)2x SHAPED
SEE NOTES 2 & 3(2) 2x TOP PLATE
CMU
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 53219
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20243:05:18PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 13S05
LASTSAVEDBY:
PROJECT NO. FILE NAME:
ABE
RYW
STRUCTURAL
11843A1013S005.dgn
1/8"GAP(TYP)
CMU BLOCK
TOP CHORD OF TRUSS
AND MATCH TOP ELEVATION
ROOF SLOPE 12H : 4V
EL VARIES. SHALL SATISFY
SCALE:FILE:
G
3/4" = 1'-0"
11843A1013S300
SECTION
SCALE:FILE:
5 11843A1013S400
DETAIL
1" = 1'-0"
WALL
WALL
(TYP)
INTO CMU (TYP)
W/ 12" EMBED
ANCHOR BOLT
1/2"Ø F1554
13S02
13S02
SECTIONS AND DETAILS 3
GENERAL NOTES:
STRONG-TIE A35SIMPSON
2x FASCIA
(2) 2x TOP PL
NOTES 3 & 4
(2) 2x TOP PLATE SEE
(TYP)
2x BLOCKING
BLOCKING
2x CONT SHAPED
SEE ARCHITECTURAL DWGS
2x RAKE FASCIA BOARD.
NOTES 2 & 3
(2) 2x TOP PLATE SEE
2x BLOCKING (TYP)
SEE ARCHITECTURAL DWGS
2x EAVE FASCIA BOARD.
A35 CLIP (TYP)STRONG-TIE SIMPSON
A35 (TYP)
SIMPSON STRONG-TIE
CAMPUS OAKS ASR WELL
EQ
BLOCKING DETAILS
FASCIA AND SOFFIT
DRAWINGS FOR
SEE ARCHITECTURAL
45 A35 CONNECTORS.
5. PROVIDE (12) 0.131" x 1 1/2" FASTENERS AT SIMPSON STRONG-TIE OPPOSITE FACES OF MEMBER.
4. STAGGER SIMPSON STRONG-TIE A35 CLIPS WHEN INSTALLED ON TOP PLATE AT SPLICE LOCATION.
3. PROVIDE SIMPSON STRONG-TIE MSTA 21 STRAP AT EACH SIDE OF TOGETHER WITH 10d NAILS @6".PRESSURE TREATED. STAGGER STITCH NAIL TOP PLATES
2. (2) 2x10 TOP PLATE FOR 12x8x16 CMU. TOP PLATE SHALL BE 1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES. rwelch
D
19S03
E
19S03
CHEMICAL ROOM
ELECTRICAL ROOM
PUMP ROOM
RESTROOM
12" FULLY
GROUTED CMU
WALL (TYP)
5' - 4" 8' - 0" 28' - 8" 6' - 8"
90' - 0"
4' - 8" 8' - 0"
28' - 0"
34' - 4" 11' - 4" 44' - 4"
3' - 4" 6' - 8" 3' - 4" 8' - 8" 3' - 4" 2' - 8"
13' - 4" 14' - 8"
2' - 8"
51' - 4" 38' - 8"
3'-0" SQ SUMP
8' - 4"
17' - 0"
CHEMICAL TANK
PAD
SEE DWG 19M09 FOR WELLHEAD
AND PUMP CONCRETE PEDESTAL
DETAILS. 3'-6" MINIMUM PEDESTAL
DIAMETER. FINAL DIMENSIONS
PER APPROVED PUMP SEISMIC
ANCHORAGE REQUIREMENTS.
4' - 8"
1' - 0"
31' - 2"
9' - 6"
F
19S03
22' - 0" 22' - 0" 24' - 0" 22' - 0" CJ/MCJ CJ CJ/MCJ
TYP
SD702 (TYP) TYP
EM118
HPT 131.50
HPT 131.50
HPT 131.50
HPT 131.50
HPT 131.50
HPT
131.50
LPT 131.47
TOC 131.50
(2) #6 ADD BARS T&B (TYP)
TYP
TYPICAL WALL SF220
DOWELS
TYP
SF230 SINGLE DOWEL IN CORNERS
& INTERSECTIONS
TYP
SD382
TYP
SF230
8" (TYP)
JAMB BAR
DOWELS (TYP)
W/O
WSTP
1' - 0"
(TYP)
1' - 0"
9' - 4"
(TYP)
TYPICAL WALL DOWELS
SEE DETAIL 2/09S04
HPT 131.50
LPT 131.43
#6 DIAGONAL BARS
T&B (TYP)
2' - 6" 4' - 11" 5' - 6" 4' - 3"
8"
2' - 0"
7"
1' - 2"
8' - 6"
1' - 2"
8"
1' - 2"
5' - 6" 16' - 7 1/2"
8"
1' - 0"
TYP
SF220
RIM 131.50
INV 130.50
1'-0" WIDE
TRENCH
MIN 0.7%
SLOPE
RIM 131.35
INV 130.50
RIM 131.35
INV 130.10
RIM 131.50
INV 130.50
MAX 2%SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
HPT 131.50 HPT 131.50
H
19S04
1' - 0"
3' - 4" 8' - 0" 3' - 4"
1' - 4"
14' - 8" 2' - 8" 22' - 8" 1' - 4"
3' - 4" 2' - 8"
29' - 4" 2' - 8" 2' - 8" 29' - 4"
TYP
THICKNESS = 12" SD503
TYP
1" SD382
5' - 0"
EJ
3' - 4" 9' - 4"
2' - 0" MCJ
20' - 8" 10' - 0" 8' - 0"
ZURN #ZF806-HDS-BDE 6"
WIDE TRENCH
STAINLESS
STEEL COVER
RIM 131.30
26' - 11"
TOC 131.50
1/8"/FT
SLOPE
RIM 131.40
RIM 131.40
TYP
(TYP) SC012
TYP
SD512 (SIM)
W/O BASE PLATE
INV 130.31
INV 129.76
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 1:06:13 PM
R:\d1341486\11843A1019S801.rvt
19S01
MISTY WOODS ASR WELL
FOUNDATION PLAN 46
STRUCTURAL
EQ
RYW
ABE
SCALE:
PLAN A 1/4" = 1'-0"
1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
2. SEE DRAWING 19S02 FOR STRUCTURE DESIGN CRITERIA.
3. SEE DRAWING 19S03 FOR STRUCTURE FOUNDATION DESIGN
CRITERIA.
GENERAL NOTES:
2 '-3"9'-9"4'-0"9'-9"2'-3"
2'-0"OVERHANG(TYP)
2'-0" 43 PRE-ENGINEERED STANDARD TRUSSES @ 2'-0" = 86'-0" 2'-0" 2'-0" OVERHANG (TYP) 32'-0"
No. 53219
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:54:32AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19S02
LASTSAVEDBY:
PROJECT NO. FILE NAME:
ABE
RYW
STRUCTURAL
ROOF PLANS
11843A1019S002.dgn
rwelch
(TYP)
INTERIOR PANEL EDGES
BLOCKING
SHAPED RIDGE
(TYP)
SHEATHING (TYP)
PLYWOOD ROOF
STANDARD 4'x8'
SLOPE
4V:12H
SLOPE
(TYP)
OF BUILDING
G
5 C
ROOF RIDGE L
(TYP)
STANDARD TRUSS
PRE-ENGINEERED
(TYP)
EDGE NAILING
INTERIOR PANEL
NAILING (TYP)
BOUNDARY
DIAPHRAGM
(TYP)
WITH BLOCKING
ALIGN PANEL EDGE
19S05
19S05
B
11843A1019S100
3/16" = 1'-0"
ROOF FRAMING PLAN
C
11843A1019S101
3/16" = 1'-0"
ROOF SHEATHING PLAN
F
19S03
E
19S03
D
19S03
G
19S05
D
19S03
E
19S03
F
19S03
G
19S05
(TYP) G
19S05
HATCH DESIGN REQUIREMENTS
SEE MECHANICAL DRAWINGS FOR
GENERAL NOTES:
REMAIN PERMANENTLY A PART OF TRUSS SYSTEM.BRACING SHALL NOT BE REMOVED AND SHALLRECOMMENDATIONS DURING TRUSS ERECTION. LATERALPER PRE-ENGINEERED TRUSS MANUFACTURER'S
3. ALL TRUSSES SHALL BE LATERALLY BRACED FOR STABILITY 2. TRUSS LOADING SEE SR620 / TYP.
WIDTH CHORD AND WEB MEMBERS.
1. ALL ROOF TRUSSES SHALL HAVE DUAL 1.5" NOMINAL
III TRUSS NOTES:
K
19S04 BELOW ROOF FRAMING
BATHROOM WALLS
4V:12H
# KEY NOTES:
(TYP)
2x OUT LOOKER 2x BLOCKING (TYP)
(TYP)
LOOKER
2x OUT
(TYP)
2x BLOCKING
ARCHITECTURAL DWGS (TYP)
EAVE FASCIA BOARD. SEE
(TYP)
2x BLOCKING
(TYP)
2x OUT LOOKER
1 STRAP 8 FOOT LONG (TYP)SIMPSON STRONG TIE CS16 COIL
NAILING (TYP)
BOUNDARY
DIAPHRAGM
2. STAGGER NAILS AT ADJOINING PANEL EDGES.
10d NAILS AT 6" SPACING.
C. INTERIOR PANEL:
10d NAILS AT 4" SPACING.BOUNDARIES:
B. NORTH AND SOUTH DIAPHRAGM
10d NAILS AT 6" SPACING.
A. EAST AND WEST DIAPHRAGM BOUNDARIES:
1. NAILING SCHEDULE:SHEATHING:
I ROOF SHEATHING: 15/32" STRUCTURAL 1 C-D
BLOCKED WITH FULL DEPTH BLOCKING.
2. ALL EDGES OF PLYWOOD SHEATHING SHALL BE
TRUSS TOP.
1. PROVIDE 2X FULL DEPTH BLOCKING BETWEEN
II FRAMING NOTES:
1. PROVIDE SIMPSON STRONG-TIE CS16 COIL STRAP AT OPENING.
MISTY WOODS ASR WELL
EQ
(TYP AROUND OPENING)
DOUBLE TRUSS
(TYP)
ARCHITECTURAL DWGS AND SOFFIT. SEE
RAKE FASCIA BOARD
47 TOP PLATE AT SPLICE LOCATIONS.
6. PROVIDE SIMPSON STRONG-TIE MSTA 21 STRAP AT EACH SIDE OF TOGETHER WITH 10d NAILS @6".PRESSURE TREATED. STAGGER STITCH NAIL TOP PLATES
5. (2) 2x10 TOP PLATE FOR 12x8x16 CMU. TOP PLATES SHALL BE FOR CLARITY.
4. ROOF UNDERLAYMENT AND STANDING SEAM ROOFING NOT SHOWN SIZE AND LOCATION.
3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR PENETRATION B. IMPORTANCE FACTOR, Iw: 1.0.A. EXPOSURE FACTOR: C.
4. WIND DESIGN CRITERIA:
E. SEISMIC RESPONSE COEFFICIENT, Cs: 0.1335.D. RISK CATEGORY: IV.C. IMPORTANCE FACTOR: 1.5.B. ANALYSIS PROCEDURE: ASCE 7-16 § 12.8.1. SPECIAL REINFORCED MASONRY SHEAR WALL, R: 5.A. BASIC SEISMIC FORCE RESISTING SYSTEM:
3. SEISMIC DESIGN CRITERIA:
C. SLAB AND EQUIPMENT: SELF WEIGHT. GROUTED: 133 PSF.B. WALL: NORMAL WEIGHT 12" CMU, SOLID A. ROOF: 25 PSF.
2. DESIGN DEAD LOAD:
SINGLE WHEEL POINT LOAD.C. FLOOR: 200 PSF DISTRIBUTED LOAD, 8,000 LBS B. GRATING: 100 PSF.A. ROOF: 20 PSF.
1. DESIGN LIVE LOAD:
2. STRUCTURAL DESIGN CRITERIA.1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
PUMP
PEDESTAL
1 19S04
1 2
(TYP)
(TYP)
TOC VARIES,
SEE PLAN
2x OUT LOOKER (TYP)
PRE-ENGINEERED
STANDARD TRUSS (TYP)
2x BLOCKING (TYP)
2 19S04
(SIM)
(TYP)
TYP
SF220
12 4
2 19S04
TOC VARIES,
SEE PLAN
TYP
(TYP) SF220
(2) #5 ADD BARS IN
ADDITION TO TYPICAL
WALL HORIZONTAL
REINFORCING 4'-0" LONG
TRUSS NOT SHOWN
FOR CLARITY
T.O.W. 145.50
12 4
3 19S04
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 1:06:14 PM
R:\d1341486\11843A1019S801.rvt
19S03
MISTY WOODS ASR WELL
SECTIONS AND DETAILS 1 48
STRUCTURAL
EQ
RYW
ABE
SCALE:
SECTION
1/4" = 1'-0" 19S01
D
SCALE:
SECTION
1/4" = 1'-0" 19S01
E
SCALE:
SECTION
1/4" = 1'-0" 19S01
F
KEY NOTES:
1. AGGREGATE BASE PER SPECIFICATION 02050 AND 02300.
2. SUBGRADE PREP:
A. SCARIFY TO A DEPTH OF AT LEAST 10 INCHES.
B. MOISTURE CONDITION SOIL TO AT LEAST 3 PERCENT ABOVE
OPTIMUM MOISTURE CONTENT.
C. COMPACT SUBGRADE TO AT LEAST 90 PERCENT RELATIVE
COMPACTION.
#
1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
2. NET ALLOWABLE BEARING PRESSURES:
A. DEAD LOAD ONLY: 2,500 PSF.
B. DEAD + LIVE LOAD: 2,500 PSF.
C. TOTAL (INCLUDING WIND OR SEISMIC): 3,333 PSF.
GENERAL NOTES:
#6@12" EW T&B (TYP)
#6@12" EW T&B
#6@12" EW EF
(TYP)
(TYP)
LAP SPLICE
1' - 0"
(TYP)
1' - 0"
(TYP)
1' - 0"
1 1
1 1
TYP
SD102
CLSM FILL. AT
CONTRACTOR'S
OPTION
1' - 6"
#5@16" EW EF (TYP
ALL CMU WALLS) SPLICE LAP
TOC VARIES,
SEE PLAN
#5 DOWELS
(TYP)
(2) #5 CONT
#6@12" x 5'-0" CENTERED ON TRENCH
T.O.W. 145.50
SPLICE
LAP
2' - 0"
1 1
2' - 8"
(TYP)
LAP SPLICE
#6@12" EW T&B (TYP)
#6@12" x 5'-0"
CENTERED ON
TRENCHVARIES
1 1
1 1
#6 BENT BAR @12"
CENTERED ON TRENCH
6' - 4"
2' - 0" 9"
2' - 8"
10"
#6@12" x 4'-0"
CENTERED ON
TRENCH
(TYP)
LAP SPLICE
T.O.W. 140.83
TOC 131.50
TYP
SF220
RESTROOM CEILING PLAN
J
-
2X6 (TYP)
2X6 (TYP)
(4) EQ SPACES = 9' - 4"
(3) EQ SPACES = 7' - 4"
SIMPSON STRONG TIE
HTT4 W/ (18) #10 x 1 1/2" SD
SCREWS (TYP)
SIMPSON STRONG TIE JB26
TOP MOUNTED HANGER (TYP)
TYP
SF062 5/8"Ø W/ 6" EMBED
(TYP)
SIMPSON STRONG TIE 18"
LONG CMSTC16 COIL STRAP
(TYP @ EACH JOIST)
SIMPSON STRONG TIE
A35 CLIP
SIMPSON STRONG TIE LU26
FACE MOUNTED HANGER (TYP)
15/32 STRUCTURAL 1 C-D SHEATHING.
10d @ 6" NAIL SPACING
2x6 PRESSURE
TREATED LEDGER
TYP
SF062 5/8"Ø W/ 6" EMBED
T.O.W. 140.83
TOP OF WALL (BEYOND)
2x6 DF BEAM (TYP)
PLYWOOD SHEATHING
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/6/2024 1:06:15 PM
R:\d1341486\11843A1019S801.rvt
19S04
MISTY WOODS ASR WELL
SECTIONS AND DETAILS 2 49
STRUCTURAL
EQ
RYW
ABE
SCALE:
DETAIL
19S03 1/2" = 1'-0"
1 SCALE:
DETAIL
3/8" = 1'-0" 19S03
2 SCALE:
DETAIL
19S03 1/2" = 1'-0"
3 SCALE:
SECTION
3/8" = 1'-0" 19S01
H
SCALE:
PLAN K 1/2" = 1'-0"
SCALE:
J
-
SECTION
1 1/2" = 1'-0"
1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES.
2. BATHROOM ROOF LOADING:
A. LIVE LOAD: 15 PSF
B. DEAD LOAD: 20 PSF
3. PROVIDE 3/4" BEVEL OR CHAMFER (REFER TO SECTION 03102).
4. SEE KEY NOTES ON DRAWING 19S03 FOR BUILDING
FOUNDATION SUBGRADE MATERIALS AND PREPARATION.
GENERAL NOTES:
4'-0"
4'-0"
2'-1"
2'-1"
4'-0"
4'-0"
1/8"GAP
2'-0"
CMU
53/4"
2'-0"
2'-0"
2'-0"OC(TYP)
(TYP)LOOKER2x OUT-
(TYP)STANDARD TRUSSPRE-ENGINEERED
A35 CLIP (TYP)SIMPSON STRONG-TIE
BLOCKING (TYP)2x SHAPED
SEE NOTES 2 & 3(2) 2x TOP PLATE
CMU
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 53219
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20243:05:18PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19S05
LASTSAVEDBY:
PROJECT NO. FILE NAME:
ABE
RYW
STRUCTURAL
11843A1019S005.dgn
1/8"GAP(TYP)
CMU BLOCK
TOP CHORD OF TRUSS
AND MATCH TOP ELEVATION
ROOF SLOPE 12H : 4V
EL VARIES. SHALL SATISFY
SCALE:FILE:
G
3/4" = 1'-0"
11843A1019S300
SECTION
SCALE:FILE:
5 11843A1019S400
DETAIL
1" = 1'-0"
WALL
WALL
(TYP)
INTO CMU (TYP)
W/ 12" EMBED
ANCHOR BOLT
1/2"Ø F1554
19S02
19S02
SECTIONS AND DETAILS 3
GENERAL NOTES:
STRONG-TIE A35SIMPSON
2x FASCIA
(2) 2x TOP PL
NOTES 3 & 4
(2) 2x TOP PLATE SEE
(TYP)
2x BLOCKING
BLOCKING
2x CONT SHAPED
SEE ARCHITECTURAL DWGS
2x RAKE FASCIA BOARD.
NOTES 2 & 3
(2) 2x TOP PLATE SEE
2x BLOCKING (TYP)
SEE ARCHITECTURAL DWGS
2x EAVE FASCIA BOARD.
A35 CLIP (TYP)STRONG-TIE SIMPSON
A35 (TYP)
SIMPSON STRONG-TIE
MISTY WOODS ASR WELL
EQ
BLOCKING DETAILS
FASCIA AND SOFFIT
DRAWINGS FOR
SEE ARCHITECTURAL
50 A35 CONNECTORS.
5. PROVIDE (12) 0.131" x 1 1/2" FASTENERS AT SIMPSON STRONG-TIE OPPOSITE FACES OF MEMBER.
4. STAGGER SIMPSON STRONG-TIE A35 CLIPS WHEN INSTALLED ON TOP PLATE AT SPLICE LOCATION.
3. PROVIDE SIMPSON STRONG-TIE MSTA 21 STRAP AT EACH SIDE OF TOGETHER WITH 10d NAILS @6".PRESSURE TREATED. STAGGER STITCH NAIL TOP PLATES
2. (2) 2x10 TOP PLATE FOR 12x8x16 CMU. TOP PLATE SHALL BE 1. SEE DRAWING 00GS01 FOR GENERAL STRUCTURAL NOTES. rwelch
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20241:42:59PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
11843A1000GM001.dgn
X KEY TAG
PIPING SYMBOLS MECHANICAL SYMBOLS
V
K
ECCENTRIC PLUG VALVEMUD VALVE (PLAN VIEW)
ELBOW, 11.25 DEGREE
ELBOW, 22.5 DEGREE
SWING CHECK VALVE
FLEXIBLE COUPLING ADAPTERDISMANTLING JOINT
WAFER CHECK VALVE
GLOBE VALVE
ANCHORCAP
CROSS
LATERAL
TEE
UNION
FLANGED COUPLING ADAPTER
GROOVED END ADAPTER
FLANGED COUPLING ADAPTER
FLEXIBLE COUPLING
EXPANSION COMPENSATOR
ELBOW, 90 DEGREE
LUBRICATED PLUGBALL CHECK VALVE
KNIFE GATE VALVE
MIXING VALVE
DUAL CHECK VALVEDIAPHRAGM VALVE
FLANGE
ELBOW, 45 DEGREE
EXP JOINT
PINCH VALVE
PLUG VALVE
(RUBBER GASKET)
FLANGED JOINT
ADAPTER SIDETHRUST TIES
WITH THRUST TIESWELDED JOINT
CONTROL VALVEGATE VALVEBALL VALVECHARACTERIZED BALLBUTTERFLY VALVE
TEE DOWNMETAL BELLOWS EXP JOINT
FLEXIBLE COUPLING WITH
ELASTOMER BELLOWS
HUB & SPIGOT JOINT
GROOVED END JOINT
CONCENTRIC REDUCER
ELBOW DOWNELBOW UPTEE UP
LATERAL DOWNLATERAL UP
VALVE
(RESTRAINED)PUSH-ON JOINT
3-WAY GLOBE TYPE
NEEDLE VALVEPREVENTERCHECK BACKFLOW
MS
X
M
PUMP: ROTARYPUMP: METERINGCAVITYPUMP: CENTRIFUGALPUMP: PLUNGER
VENTURI TUBE
STRAINER: WYE TYPEWITH BLOWOFF
WEIR
SLUICE GATE
PUMP: DIAPHRAGM
TELESCOPING VALVE
VALVE: AIR RELIEFVALVE: ANGLE
PULSATION DAMPENERPRIMARY FLOW ELEMENT:PUMP: RECIPROCATINGPUMP: PROGRESSIVE X = U - ULTRASONICX = TH - THERMALX = R - ROTAMETERX = M - MAGNETICX = C - CORIOLISPRIMARY FLOW ELEMENT:
PUMP: SUBMERSIBLE
PUMP: SCREW
FLUME
PRIMARY FLOW ELEMENT: ORIFICE PLATEX = PT - PITOT TUBE
ROTARY CHEMICALRUPTURE DISK
SLIDE GATE
SAMPLE PORT
SIGHT GLASS
FEEDER
PRIMARY FLOW ELEMENT:X = T - TURBINEX = P - PROPELLER
PRIMARY FLOW ELEMENT:
X = D - DENSITY
FLOW SWITCHFIRE HYDRANT
RADARPRIMARY LEVEL ELEMENT:
THERMOMETER
W/ EXTERNAL PRESSURE TAPBACKPRESSURE REGULATOR
THREE WAY VALVE
BACKPRESSURE REGULATOR
PUMP: PERISTALTIC TUBE METERING
THREE WAY VALVETHREE WAY VALVEMOTOR OPERATED
SELF-CONTAINED
AIR OPERATEDSOLENOID OPERATED
PRESSURE-REDUCINGPRESSURE-REDUCINGREGULATOR: SELF-CONTAINED DIFFUSERAIR VENTOR FLUSHINGRECIPROCATINGDRAINBLOWERQUICK DISCONNECTPRIMARY LEVEL ELEMENT:HIGH PRESSURE AIRBATCHMETERAIR OR CHEMICALCOMPRESSOR:ELECTRIC MOTOREXPANSION JOINT,EQUIPMENT DRAIN PUMP: VERTICAL LIFT
PIPE REDUCER: CONCENTRIC
FLEXIBLE VIBRATIONCOMPRESSOR/TURBINECALIBRATION COLUMNDIAPHRAGM SEALJOINTEJECTOR OR EDUCTORFLAME ARRESTERFLOOR DRAINFLAME ARRESTER WITHPRESSURETHERMALLY OPERATED VALVEFAN: EXHAUST/SUPPLYFILTERWEIRFLOAT SWITCH ULTRASONICPRIMARY LEVEL ELEMENT:
OIL OR MOISTURE TRAPGAUGE: PRESSUREGAUGE: DIFFERENTIALMIXERPRIMARY LEVEL ELEMENT:BUBBLER
BASKET STRAINER
PRIMARY LEVEL ELEMENT:ELECTRODEPRIMARY LEVEL ELEMENT:FLUID
SINGLE LINE DESCRIPTION SINGLE LINE DESCRIPTION SINGLE LINE DESCRIPTION
DOUBLE LINE SINGLE LINE DESCRIPTION SINGLE LINE DESCRIPTION
IDENTIFICATION SYMBOLS
PROCESS LINE SYMBOLS
LINE SYMBOLS
CONTINUATION TO DWG NO.CONTINUATION FROM DWG NO.
UNIQUE IDENTIFIER
CHEMICAL INJECTION POINT
CONTINUATION TAG
PIPE ABOVE OR BELOW GROUND
DEMO
EXISTING
FUTURE
OR STRUCTURE
PIPE UNDERNEATH SLAB PRIMARY PROCESS FLOW IN CHANNEL
SECONDARY PROCESS FLOW IN CHANNEL
PRIMARY PROCESS FLOW IN PIPE
SECONDARY PROCESS FLOW IN PIPE
PIPE DESIGNATOR
EQUIPMENT / VALVE TAG
PIPE SIZE FLOW STREAM
PIPE MATERIAL CHANGE
M
XXX-XX-XXXX
X" XXX
C
B
A
DWG NO.
CHEMICAL
(FOT. FOB)ECCENTRIC REDUCER
(FOT, FOB)PIPE REDUCER: ECCENTRIC
PLUG VALVECONCENTRIC
FOUR WAY VALVE
CONE VALVEPRESSURE RELIEFREGULATORPRESSURE-REDUCINGVACUUM VALVE REGULATOR W/EXTERNAL PRIMARY LEVEL ELEMENT: STRAINER: WYE TYPEPRESSURE TAP INVERTED COLUMN
MECHANICAL
GENERAL MECHANICAL NOTES AND LEGEND
51 HOSE VALVE, BIB
ROTAMETER
SILENT CHECK VALVE
00GM01
DM
rlinsenmann
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:07:46AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
GENERAL PLUMBING NOTES, ABBREVIATIONS,
AND SYMBOLS
11843A1000GM002.dgn
WT (SANITARY) WASTE
WALL CLEANOUTVENT THROUGH ROOFTANK DRAINSHOCK ABSORBER
NON-POTABLE WATERHOSE END VALVEFACE/BODY SPRAYFLOW ALARM SWITCH
W&VW&TWHWFWCOWVTRVACUNOTYPTDT&PSSKSKSFSA
OEDNPWMAXLSVKUKSIPSIOSINVHWRHPHEVF/BSFSFASEWUESEWESECODCOCONTBOPBLDGBFPLBV S
ADAFF@ AT
AREA DRAINABOVE FINISHED FLOOR
BWV
BACKFLOW PREVENTERBUILDINGBOTTOM OF PIPEBACKWATER VALVE
CL CENTERLINECACICOCW
COMPRESSED AIRCAST IRONCLEANOUTCONTINUOUS, CONTINUECUBIC FEETCHECK VALVECOLD WATER
CU FTCVDIDNDWG
DRAINDOUBLE CLEANOUTDUCTILE IRONDOWNDRAWING
ELEWC
EMERGENCY WATER EXTERIOR CLEANOUTELEVATIONEMERGENCY SHOWEREMERGENCY SHOWER / EYEWASH STATIONELECTRIC WATER COOLEREYE WASH UNIT
FCOFDFEFHV&CFV
FLOOR CLEANOUTFLOOR DRAINFIRE EXTINGUISHERFIRE HOSE VALVE AND CABINETFLOW SWITCHFIRE VALVE GPM
GASGALLONS PER MINUTE
HBHDHW
HOSE BIBBHUB DRAINHANDICAPPED (ADA ACCESSIBLE)HOT WATERHOT WATER RETURNINVERTINSTALLED BY OTHER SECTIONIRON PIPE SIZEKITCHEN SINKKITCHEN UNIT LABLAV
LABORATORYLAVATORYLOCKABLE BALL VALVELOCK SHIELD VALVE
MINMR
MAXIMUMMINIMUMMOP RECEPTOR
ND NUMBER
OPEN END OR OPEN EQUIPMENT DRAIN
RPBP
R RD
RM
ROOF DRAINROOMBACKFLOW PREVENTER
SSHSHTSPSQSS
SOILSQUARE FOOTSHOWERSHEETSPRINKLERSQUARESANITARY SEWERSINKSAMPLE T
THKTPTWTWH
TEMPERATURE & PRESSURE RELIEFTHICK(NESS)TRAP PRIMERTEPID WATERTANKLESS WATER HEATERTYPICAL U
UR
UNLESS NOTED OTHERWISEURINAL
V V
VBVE
VENTVACUUMVACUUM BREAKERVACUUM EXHAUST
W
W/WCWHS
WASTEWITHWATER CLOSETWASH FOUNTAINWALL HYDRANTWASH HOSE STATIONWASTE & TRAPWASTE & VENT
CLEANOUT
CO
FLOOR CLEANOUT
WCO WALL CLEANOUT
YCO
HUB DRAINHOSE RACKWATER PROOF SLEEVE
"DROP" DENOTES PIPES WHICH DO NOT."DN" DENOTES PIPE WHICH PENETRATE THE FLOOR BELOW.
DN OR DROP
"RISE" DENOTES PIPES WHICH DO NOT."UP" DENOTES PIPE WHICH PENETRATE THE FLOOR ABOVE.
UP OR RISE
DIRECTION OF FLOW WITHIN THE PIPE LINE.THE TERMS HAVE NO RELEVANCE TO THEIMAGINARY PLANE OF VIEW.IN WHICH A PIPE LINE CONTINUES FROM THEUSED TO INDICATE THE VERTICAL DIRECTION NOTE:THE TERMS "DN" "DROP" "UP" & "RISE" ARE
ETP ELECTRONIC TRAP PRIMEREWH ELECTRIC WATER HEATER
OR
FLOOR DRAIN
P-TRAPTEETEE UPTEE DOWNLOCKABLE BALL VALVECHECK VALVEGATE VALVEBALL VALVEGLOBE VALVEBUTTERFLY VALVEPLUG VALVEPRESSURE REGULATOR VALVE
VENTSOIL OR WATER (DRAINAGE)TEMPERED WATER (POTABLE)NON-POTABLE WATERNEW SANITARY SEWEREXISTING SANITARY SEWERNEW COLD WATER (POTABLE)EXISTING COLD WATER (POTABLE)NEW HOT WATER (POTABLE)EXISTING HOT WATER (POTABLE)
REDUCED PRESSURE
DOUBLE YARD CLEANOUTHOSE BIBB OR WALL HYDRANT
WHA WATER HAMMER ARRESTOR
FLOW CONTROLVALVECOLD BYPASS
HWS HOT WATER SUPPLY
ABBREVIATIONS PLUMBING LINE SYMBOLS
PLUMBING SYMBOLS
POUNDS PER SQUARE INCHPROTECTED WATER
P&TPSLPSIPRHPRWEDPHW
CAD
E
F
G
K
L
O
P P
PDPGPHPVCPW
PUMP DISCHARGEPRESSURE GAUGEPOST HYDRANTPROTECTED HOT WATERPRESSURE WATERHIGH PRESSURELOW PRESSUREPRESSURE & TEMPERATUREPOLYVINYL CHLORIDEPOTABLE WATER APPEAR ON THE CONTRACT DRAWINGS.ABBREVIATIONS. NOT ALL ITEMS SHOWN HERE NOTE:THIS IS A GENERAL LIST OF SYMBOLS AND
UNIONBOTTOM CONNECTIONTOP CONNECTIONBACKFLOW PREVENTERREDUCED PRESSURETEMPERATURE GAUGERE-CIRCULATION PUMP B
G
H
I
M
N
52 PLUMBING 00GM02
jshaffer
CG
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:08:10AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
HUMIDISTATTHERMOSTAT 60" ABOVE FINISH FLOOR
ROOF VENT OR ROOF FANUNIT HEATER (HORIZONTAL TYPE)
INLINE/AXIAL FANROOF/SIDEWALL FANCENTRIFUGAL FAN
DIRECT EXPANSION COILCOOLING COILCONTROL PANELSOLENOID VALVEGAS HEATER
ELECTRIC HEATER
FILTER
MOTOR OPERATED VALVE
UNIT HEATER (VERTICAL TYPE)
TURNING VANESFLEXIBLE DUCTACCESS DOOR
FLEXIBLE CONNECTION
SIDE MOUNT DEVICE
ROUND DUCT
DIRECTION OF FLOW
TO SPACEFROM SPACE
20x12 16 DIA20x12 16x8
AD
AD
R
20x1220x12
12x20
NOTES DUCTWORK SYMBOLS EQUIPMENT SYMBOLS REGISTERS, GRILLES & LOUVERS SYMBOLS
MOTORIZEDBACKDRAFTBALANCING
OR
FD
FEATURE SYMBOL FEATURE SYMBOL FEATURE SYMBOL
DAMPERS
SUPPLY RETURN EXHAUST
M
M
FIRE W/ ACCESS DOOR
DUCT SMOKE DETECTOR
9. PROVIDE TURNING VANES IN ALL ELBOWS. (SHOWN OR NOT)
8. COORDINATE FINAL LOUVER SIZE AND LOCATION WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
OUT AT ALL LOCATIONS WHERE THEY APPLY.
7. TYPICAL DETAILS SHALL BE USED FOR ALL PERMANENT WORK EVEN THOUGH THEY ARE NOT CALLED
6. THIS IS A GENERAL LIST OF SYMBOLS. NOT ALL ITEMS SHOWN HERE APPEAR ON CONTRACT DRAWINGS.
FURNISHED AND INSTALLED BY THE CONTRACTOR AS SPECIFIED.
OTHERWISE DETAILED ON THE DRAWINGS ALL PIPE AND DUCT SUPPORTS SHALL BE DESIGNED,
5. NOT ALL AND ONLY CERTAIN TYPES OF SUPPORTS ARE SHOWN ON THE HVAC DRAWINGS. UNLESS AS SHOWN ON THE TYPICAL DETAILS.
4. UNLESS OTHERWISE SHOWN ON THE DRAWINGS ALL FLOOR SLAB AND WALL PENETRATIONS SHALL BE HVAC SYSTEMS TO PROVIDE THE COMPLETE SYSTEM.
NOT EVERY FITTING AND OFFSET IS SHOWN. THE CONTRACTOR SHALL FURNISH, INSTALL AND TEST ALL ETC. REQUIRED FOR THE COMPLETE SYSTEM. SMALL PIPING IS SHOWN APPROXIMATELY TO SCALE BUT
3. HVAC PIPING AND DUCTWORK DRAWINGS DO NOT SHOW ALL DRAINS, VENTS, OFFSETS AND FITTINGS PIPE TO OTHER TYPES OF METALLIC PIPING.
2. DIELECTRIC COUPLINGS, FLANGES OR UNIONS SHALL BE INSTALLED AT ALL CONNECTIONS OF COPPER STRUCTURAL DRAWINGS.
EQUIPMENT SHALL BE SET ON CONCRETE PADS CONFORMING TO DETAILS SHOWN ON THE TYPICAL SHALL BE DETERMINED BY THE CONTRACTOR FOR THE EQUIPMENT FURNISHED. ALL FLOOR MOUNTED
1. SIZES OF EQUIPMENT PADS INDICATED ON THE DRAWINGS ARE APPROXIMATE. EXACT DIMENSIONS
FIRST NUMBER IS TOPDUCT SECTION, NEGATIVE PRESS FIRST NUMBER IS TOPDUCT SECTION, POSITIVE PRESS
RISE, (D) DROPELEVATION CHANGE (R)
IS SIDE SHOWNDUCT SIZE- FIRST NUMBER
COMPRESSORA/C OR HEAT PUMP
TRANSFER GRILLEARROWS INDICATE FLOW DIRECTIONSUPPLY DIFFUSER OR GRILLEARROWS INDICATE FLOW DIRECTIONRETURN DIFFUSER OR GRILLEARROWS INDICATE FLOW DIRECTIONEXHAUST DIFFUSER OR GRILLE
OR DUCT TAKEOFF REGISTER, GRILLE, DIFFUSERBOTTOM MOUNT DEVICE
TRANSITION RECTANGULARRECTANGULAR TO ROUND TRANSITION RECTANGULAR TOPRESSURE) DIAGONAL FOR NEGATIVEELBOW TURNED UP (USE ONEPOSITIVE PRESSURE DUCT -PRESSURE) DIAGONAL FOR NEGATIVEELBOW TURNED DOWN (USE ONEPOSITIVE PRESSURE DUCT -
INSTALLATION
CONFIRM ORIENTATION OF
SMOKE DETECTORINSTALLATION
CONFIRM ORIENTATION OF
SMOKE
INSTALLATION
CONFIRM ORIENTATION OFCOMBINATION SMOKE AND FIRE
T
S
M
H
TYPE OF REGISTER
SIDEWALL-ADJUSTABLE;
CFM FLOW PATTERN;
BOOT (IF REQ'D)NECK SIZEC-CORNER
(AS DESCRIBED INOR GRILLE
400/4
SR-1(B)/12x12
SPECIFICATIONS)
LEGEND FOR REGISTERS & GRILLES
PRESSURE DIFFERENTIAL SWITCH
PD
AIR FLOW SWITCH AFS
C
C
D
X
DUCT UP THRU ROOF OR FLOOR
ABBREVIATIONS
BDD BACKDRAFT DAMPERBOD BOTTOM OF DUCTAFF ABOVE FINISHED FLOORBD BALANCING DAMPER @ AT
CHDG DOOR GRILLE
EA EXHAUST AIR
FA FOUL AIR
MD
RA RETURN AIRRR RETURN REGISTER OR GRILLE
SA SUPPLY AIRSDSFDSR
SMOKE DAMPER OR SMOKE DETECTORSMOKE & FIRE DAMPER COMBINATIONSUPPLY REGISTER, GRILLE OR DIFFUSER D
A
BCEF
M
PRS
AFS AIR FLOW SWITCHAHU AIR HANDLING UNITBLR BOILER
EF EXHAUST FANEUH ELECTRIC UNIT HEATER
NCNO
NORMALLY CLOSEDNORMALLY OPEN
N
MAU MAKEUP AIR UNIT
MOTORIZED DAMPER
O OA OUTSIDE AIR
PPU POSITIVE PRESSURIZATION UNIT
W WUH WATER UNIT HEATER
AC AIR CONDITIONINGCO CARBON MONOXIDE DETECTOR
CHILLER
CTCSCU
COOLING TOWERCURRENT SENSORCONDENSING UNIT
DP DIFFERENTIAL PRESSURE
ECU EVAPORATIVE COOLING UNIT
FD FIRE DAMPERFCU FAN COIL UNIT
G GUH GAS UNIT HEATERH HP HEAT PUMP
OCF ODOR CONTROL FANSF SUPPLY FAN
V VAV VARIABLE AIR VOLUME
LOUVER/BRICK VENT - OPERABLELOUVER/BRICK VENT - FIXEDDUCT DOWNDUCT UP
CURRENT SENSOR CS
11843A1000GM003.dgn
WJS
KHB
AND SYMBOLS
GENERAL HVAC NOTES, ABBREVIATIONS,
53 AFF ABOVE FINISHED FLOOR
HVAC
jshaffer
CG
00GM03
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20245:36:36PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
DPF
11843A1000GM004.dgn
MECHANICAL
PROCESS EQUIPMENT AND PIPE SCHEDULES 1
VALVE AND PUMP STATUS FOR VARIOUS MODES OF OPERATION VALVE ACTUATOR SCHEDULE
TAG PROCESS EQUIPMENT
VALVE
TYPE
RECHARGE
(COLUMN ONLY)
RECHARGE
(COLUMN +
ANNULUS)
WASTE RECOVERY FILTER
BYPASS
MAINTENANCE
(OFF)
STORAGE
(MAINTENANCE)
VALVE
TYPE
SIZE DUTY
ACTUATOR
TYPE
NEMA
RATING VOLTAGE CONTROLS COMMENT
CAMPUS OAKS WELL 13WD34-PUIMP-30101 ASR PUMP WITH VFD SPEED CONTROL N/A OFF OFF ON ON ON OFF OFF N/A N/A N/A N/A N/A N/AWD34-FCVX-30150 AS
MODULATING RECHARGE CONTROLVALVE
BFV OPEN
(MODULATING)
OPEN
(MODULATING)
CLOSED CLOSED CLOSED CLOSED CLOSED BFV
8"
MD MOD 4X 120/1/60
WD34-MOVX-30130 AS PUMP COLUMN RECHARGE CONTROL BFV OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED BFV 12" STD O/C 4X 120/1/60WD34-VALV-30111 AS
MODULATING DOWNHOLE RECHARGECONTROL VALVE
DHCV OPEN
(MODULATING)
OPEN
(MODULATING)
CLOSED CLOSED CLOSED CLOSED CLOSED DHCV
12"
MD MOD 4X NEED TO
CONFIRM
USE THE BASKI VENDOR CONTROLPANEL
WD34-MOVX-30120 AS WELL ANNULUS RECHARGE VALVE
BFV CLOSED OPEN
(MODULATING)
CLOSED CLOSED CLOSED CLOSED CLOSED BFV
12"
STD O/C 4X 120/1/60
WD34-MOVX-30160 AR AQUIFER RECOVERY PRODUCTION BFV CLOSED CLOSED CLOSED OPEN OPEN CLOSED CLOSED BFV 12" STD O/C 4X 120/1/60 AWD34-MOVX-30140 AF AQUIFER & WELL FLUSH TO WASTE BFV CLOSED CLOSED OPEN CLOSED CLOSED CLOSED CLOSED BFV 10" STD O/C 4X 120/1/60 A TRICKLE FLOW VALVE BV CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN (MANUAL) BV 3/4" N/A O/C N/A N/A WD34-PDTX-30106 PRESSURE REDUCING VALVE 10"
MANUAL N/A N/A PRV HAS A VERTICAL INLET,
HORIZONTAL OUTLET (ANGLE
WD34-PDIT-30151 STRAINER 10" MANUAL N/A N/A VERTICAL CONFIGURATIONMISTY WOOD WELL 19WD34-PUIMP-36101 ASR PUMP WITH VFD SPEED CONTROL N/A OFF OFF ON ON ON OFF OFF N/A N/A N/A N/A N/A N/AWD34-FCVX-36150 AS
MODULATING RECHARGE CONTROLVALVE
BFV OPEN
(MODULATING)
OPEN
(MODULATING)
CLOSED CLOSED CLOSED CLOSED CLOSED BFV
8"
MD MOD 4X 120/1/60
WD34-MOVX-36130 AS PUMP COLUMN RECHARGE CONTROL BFV OPEN OPEN CLOSED CLOSED CLOSED CLOSED CLOSED BFV 12" STD O/C 4X 120/1/60WD34-VALV-36111 AS
MODULATING DOWNHOLE RECHARGECONTROL VALVE
DHCV OPEN
(MODULATING)
OPEN
(MODULATING)
CLOSED CLOSED CLOSED CLOSED CLOSED DHCV
12"
MD MOD 4X Need to
Confirm
USE THE BASKI VENDOR CONTROLPANEL
WD34-MOVX-36120 AS WELL ANNULUS RECHARGE VALVE
BFV CLOSED OPEN
(MODULATING)
CLOSED CLOSED CLOSED CLOSED CLOSED BFV
12"
STD O/C 4X 120/1/60
WD34-MOVX-36160 AR AQUIFER RECOVERY PRODUCTION BFV CLOSED CLOSED CLOSED OPEN OPEN CLOSED CLOSED BFV 12" STD O/C 4X 120/1/60 AWD34-MOVX-36140 AF AQUIFER & WELL FLUSH TO WASTE BFV CLOSED CLOSED OPEN CLOSED CLOSED CLOSED CLOSED BFV 8" STD O/C 4X 120/1/60 A TRICKLE FLOW VALVE BV CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED OPEN (MANUAL) BV 3/4" N/A O/C N/A N/A WD34-PDTX-36106 PRESSURE REDUCING VALVE 10"
MANUAL N/A N/A PRV HAS A VERTICAL INLET,
HORIZONTAL OUTLET (ANGLE
WD34-PDIT-36151 STRAINER 10" MANUAL N/A N/A VERTICAL CONFIGURATIONAbbreviations:
Type: Duty: Service: NEMA Rating: Controls:
BFV = Butterfly Valve MD = Modulating duty (~1,200 starts/hr) MOD = Modulating 4X for general locations A = Analog (4-20mA) control, modulatingBV = Ball Valve STD = Standard service (0-60 starts/hr) duty O/C - Open/Close 6P for vaults and possible submergence D JOD = Position control using discrete jumpsPV = Plug Valve XP for Class I, Division 1 and Division 2 locations D O/C - Discrete open/closeSG = Slide Gate DN = DeviceNet DP = Profibus DPE-IP = Ethernet/IP
PIPE SCHEDULE ABBREVIATIONS
ABBREVIATIONS TO DESIGNATE TEST PRESSURE/METHOD PER SPECIFICATION SECTION 15956:AM AIR METHODGR GRAVITY METHODHH HIGH HEAD METHODLH LOW HEAD METHODSC SPECIAL CASEABBREVIATIONS TO DESIGNATE PIPE MATERIAL:BSP BLACK STEEL PIPECI CAST IRONCISP CAST IRON SOIL PIPECL CLASS, FOLLOWED BY THE DESIGNATIONCPVC CHLORINATED POLYVINYL CHLORIDEDIP DUCTILE IRON PIPINGFRP FIBERGLASS REINFORCED PIPEGA GAUGE, PRECEDED BY THE DESIGNATIONGE GROOVED END JOINTGSP GALVANIZED STEEL PIPEHDPE HIGH DENSITY POLYETHYLENE PVC POLYVINYL CHLORIDESCH SCHEDULE, FOLLOWED BY THE DESIGNATIONSDR STANDARD DIMENSION RATIOSST STAINLESS STEELVCP VITRIFIED CLAY PIPINGWSP WELDED STEEL PIPEABBREVIATIONS TO DESIGNATE PIPING JOINTS/FITTINGS & COATING/LINING:B&SP BELL & SPIGOTBFW BUTT FUSION WELDBW BUTT-WRAPPEDBZD BRAZEDCF COMPRESSION FITTINGSCM CEMENT MORTAREPP EPOXY POLYURETHANE COATING (SEE SECTION 09960)FL FLANGEDGE GROOVED ENDMJ MECHANICAL JOINTNH NO HUBPEE POLYETHYLENE ENCASEMENTPO PUSH ONRMJ RESTRAINED MECHANICAL JOINTRPO RESTRAINED PUSH ONSCRD SCREWEDSFW SOCKET FUSION WELDSLD SOLDEREDSW SOLVENT WELDWLD WELDED ABBREVIATIONS TO DESIGNATE LINING AND COATINGS:CEP CERAMIC EPOXYCTP COAL TAR PITCHCM CEMENT MORTAREPP EPOXY AND POLYURETHANE COATING SYSTEM PER SECTION 09960FBE FUSION BONDED EPOXYGL GLASS LININGPEN POLYETHYLENE ENCASEDPTW POLYETHYLENE TAPE WRAPWAE WATERBORNE ACRYLIC EMULSIONZNC ZINC 00GM04
DM
54 DFassbinder
REG I ST ERED PROFESS I ONA L ENG I NEER ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20243:32:36PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
DPF
11843A1000GM005.dgn
MECHANICAL
PROCESS EQUIPMENT AND PIPE SCHEDULES 2
PIPING SCHEDULE
ABBR. SERVICE DIAMETER (INCHES) MATERIALS
3 MIN. PRESSURE
CL, SPECIAL
THICKNESS CL,
OR SCHEDULE
JOINTS/
FITTINGS
4 TEST
PRESSURE/
METHOD
1,2
LINING
5 COATING
6 PIPE SPEC
SECTION
COATING COLOR COMMENTS
AF AQUIFER FLUSH
BURIED ALL DIP 150 RPO OR RMJ 200 PSI/HH CM 2 LAYERS PEE 15244
CLEAR PEE PER CITY
CONSTRUCTION STANDARDS
CLS CHLORINE SOLUTION
EXPOSED ALL PVC SCH 80 SW
175 PSI/HH
NONE NONE 15230 YELLOW
BURIED ALL PVC SCH 80 SW NONE NONE 15230
SD STORM DRAIN
BURIED SMALLER THAN 8" PVC SDR 35 B&SP
10 FEET/GR
NONE NONE 15247
8" AND LARGER RCP MIN CLASS III B&SP NONE NONE 15229
DR DRAIN
EXPOSED,
INTERIOR
1-1/2" TO 10" PVC SCH 80 SW
10 FEET/GR
NONE NONE
15400
CONC. ENCASED ALL PVC SCH 80 SW NONE NONE
FI / FE FILTER INFLUENT / EFFLUENT
ALL 1" AND SMALLER PVC SCH 80 SW
150 PSI/HH
NONE NONE DARK BLUE
EXPOSED ALL DIP 150 RMJ OR FL CM EPP 15211 DARK BLUE
CONC. ENCASED ALL DIP 150 RMJ CM CTE 15211
BURIED ALL DIP 150 RPO OR RMJ CM 2 LAYERS PEE 15211
CLEAR PEE PER CITY
CONSTRUCTION STANDARDS
2" AND SMALLER PVC SCH 80 SW NONE NONE 15244LARGER THAN 2" PVC SCH 80 RPO NONE NONE 15244
FPW FIRE PROTECTION WATER
BURIED
ALL
DIP 150 RPO OR RMJ
200 PSI/HH
CM 2 LAYERS PEE 15244
CLEAR PEE PER CITY
CONSTRUCTION STANDARDS
CONC. ENCASED ALL DIP 250 FL OR RMJ CM CTE 15244
IRR IRRIGATION
BURIED ALL PVC SCH 40 SW 200 PSI/HH NONE NONE 15230 WHITE
NAF SODIUM FLUORIDE
EXPOSED ALL PVC SCH 80 SW
150 PSI/HH
NONE NONE 15230 GREEN
1" AND SMALLER PFA 0.0625 in CF NONE NONE
BURIED ALL PVC SCH 80 SW NONE NONE 15230
PW POTABLE WATER / SOFTENED WATER
EXPOSED 3" AND SMALLER COPPER ASTM B88 SOLDERED
200 PSI/HH
NONE NONE
EXPOSED 4" AND LARGER DIP CL 53 FL OR GE CM EPP 15211 LIGHT BLUE CONC. ENCASED 4" AND LARGER DIP 250 FL OR RMJ CM CTE 15244 BURIED ALL DIP 150 RPO OR RMJ CM 2 LAYERS PEE 15244
CLEAR PEE PER CITY
CONSTRUCTION STANDARDS
2" AND SMALLER PVC SCH 80 SW NONE NONELARGER THAN 2" PVC SCH 80 RPO NONE NONE
RW RECYCLED WATER
ALL PVC SCH 40 SW 200 PSI/HH NONE NONE 15230 PURPLE
SAM SAMPLE LINE
EXPOSED ALL PVC SCH 80 SW
150 PSI/HH
NONE NONE 15230 VARIES
BURIED ALL PVC SCH 80 SW NONE NONE
SH SODIUM HYPOCHLORITE
EXPOSED ALL CPVC SCH 80 SW
150 PSI/HH
NONE NONE 15230 YELLOW
1/2" AND SMALLER PFA 0.0625 in CF NONE NONE
SS SANITARY SEWER
EXPOSED
ALL PVC SCH 80 SW
10 FEET/GR NONE NONE 15247
LIGHT GRAY
CONCRETE
ENCASED BELOW
STRUCTURE
BURIED ALL PVC
SDR 26 PER ASTM
D3034
PO
2" PRESSURIZED PVC SCH 80 SW 150 PSI/HH NONE NONE 15230 V VENT
ALL ALL PVC SCH 80 SW 10 FEET/GR NONE NONE 15230
NOTES:
1 ALL PIPING TO BE FULLY RESTRAINED FOR HH TESTS
ABBREVIATIONS:
2 TEST PRESSURE/METHOD: METHODS ARE SPECIFIED IN SECTION 15956 - PIPING SYSTEMS TESTING.
AM AIR METHOD
GR GRAVITY METHOD
HH HIGH HEAD METHOD
LH LOW HEAD METHOD
SC SPECIAL CASE
3 MATERIALS:
DIP DUCTILE IRON PIPE
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
4 JOINTS/FITTINGS
B&SP BELL AND SPIGOT
CF COMPRESSION FITTING
FL FLANGE
GE GROOVED END JOINT
PO PUSH ON
RMJ RESTRAINED MECHANICAL JOINT
RPO RESTRAINED PUSH ON JOINT
SW SOLVENT WELDED
00GM05
DM
jshaffer
55 REG I ST ERED PROFESS I ONA L ENG I NEER ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
T
T
PUMP ROOM
CHEMICAL ROOM
ELECTRICAL ROOM
RESTROOM
B
13M02
16" PW
C
13M02
1 4
5 3
10 8
E
13M10
D
13M03
N 2047083.84
E 6736410.80
N 2047078.01
E 6736394.51
FROM DISTRIBUTION
& 2" BACKFLOW
PREVENTER
SEE CIVIL YARD PIPING PLAN
FROM 4" FDC
& BACKFLOW
PREVENTER
3" GRAVEL FILL TUBE
3 15
15 3
2" SOUNDING TUBE,
AND LEVEL
TRANSMITTER,
SEE DWG 13M10
WD34-PUMP-30101
N 2047061.09
E 6736373.39
12" AS
2 WD34-FCVX-30120
3 4" V
WD34-FCVX-30150
12" AR
3' - 0"
4" TANK VENT SEE
CHEM ROOM DWG
13M10
TYP
CY119
TYP
MP140
FROM/TO
DISTRIBUTION
CL 124.00
SEE DWG 13E11
22 7
27 9
D
16 SEE DWG 13M05
13 TO STORM DRAIN
AIR-GAP STRUCTURE
WD34-MOVX-30160
1 13M03
2 13M03
23 NITROGEN GAS
CYLINDER TANK
DHCV VCP
(x2 FOR TWO
MONITORING WELLS)
POWER AND 1"
SAMPLE LINE FROM
THE MONITORING WELL
18 17
NITROGEN
2 TUBES
NITROGEN
2 HOSES
PRELUBE AND TRICKLE
FLOW. SEE SECTION
1/13M03
12" AS/AR
PRESSURE INDICATING
TRANSMITTER
24 WD34-PITX-30109
3/4" NAF
3/4" SH
11 12
TYP
MC777
TYP
MC777
9' - 2"
10" AF
12" AS/AR
12" FE
(TYP)
5' - 0"
ENCASEMENT (TYP)
20 20
3/4" TW 12" AS/AR
WD34-MOVX-30140
WD34-MOVX-30130
12" x 10" RED
10" AS
3'-0" MIN
ROSSUM SAND
TESTER
2" PW
4" FPW
CL 124.00 CL 120.54 CL 124.00
1/4" NITROGEN VENT
26 14
21 10" AF
BYPASS
1/2" SAM
TO FUTURE 12" FI
FROM FUTURE 12" FE
L
13M09
OPERATOR INTERFACE, SEE
KEYNOTE 1 ON SHEET 13GN01
28 6
3'-0" MIN
25 GENERAL NOTES:
1. SEE CIVIL FOR PIPING CONTINUATIONS
2. NOT ALL REQUIRED PIPE SUPPORTS ARE SHOWN.
3. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING OFFSET,
SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE THE PROCESS AND INSTRUMENTATION DIAGRAMS AND SPECIFICATION SECTION 15052- COMMON WORK RESULTS FOR GENERAL PIPING.
KEY NOTES:
1. ASR WELL PUMP
2. WELL ANNULUS RECHARGE VALVE
3. 2" AIR RELEASE VALVE (TYP)
4. RESTRAINED FLANGE COUPLING ADAPTER (TYP)
5. BI-DIRECTIONAL FLOW METER
6. 1" SPARE NIPPLE AND FULL-PORT BALL VALVE FROM
CENTERLINE SIDE OF PIPE
7. AQUIFER & WELL FLUSH TO WASTE VALVE.
8. PRESSURE REDUCING VALVE.
9. MODULATING RECHARGE CONTROL VALVE.
10. AQUIFER RECOVERY PRODUCTION VALVE.
11. FLUORIDE INJECTION SIM TO TYP DETAIL MC777/TYP. ROUTE TO THE CHEMICAL TRENCH DRAIN.
12. SODIUM HYPOCHLORITE INJECTION SIM TO TYP DETAIL
MC777/TYP. ROUTE TO THE CHEMICAL TRENCH DRAIN.
13. RESTRAINED FLEXIBLE COUPLING PER TYP DETAIL MP310/TYP.
14. 1/2" AIR RELEASE VALVE, SEE DETAIL 2/13M03.
15. INSTALL DIELECTRIC ISOLATION FLANGE AT INTERFACE
BETWEEN SST WELLHEAD AND DOWNHOLE WELL PIPING FROM
DISTRIBUTION PIPING.
16. INSTALL 1" SAMPLE TAP AND BALL VALVE, 1/2" TUBING,
POOL/HOUSE WATER FILTER CARTRIDGE WITH CLEAR CASING,
AND PREFORMED CHANNEL PIPE SUPPORTS AS REQUIRED FOR
VISUAL INSPECTION AND HAND TURBIDITY TESTING. WASTE TO
DRAIN. REFER TO P&ID DRAWINGS FOR LAYOUT AND VALVES.
17. FLUORIDE ANALYZER, SEE DETAIL 4/13M03.
18. CHLORINE ANALYZER, SEE DETAIL 4/13M03.
19. NOT USED
20. ROUTE 1/2" CHEMICAL FLUORIDE AND CHLORINE TUBING FROM
THE CHEMICAL PUMPS IN THE CHEMICAL ROOM THROUGH THE
CHEMICAL TRENCH DRAIN TO THE INJECTION POINTS. 3/4" PIPE SHALL BE USED AT THE INJECTION POINTS.
21. PUMP COLUMN RECHARGE CONTROL VALVE.
22. LOCATE BURIED SAMPLE TAP OUTSIDE OF CONCRETE
ENCASEMENT. INSTALL CORPORATION STOP. SEE SITE CIVIL
YARD PIPING PLAN.
23. NITROGEN PNEUMATIC HOSES TO DOWNHOLE CONTROL VALVE
(SEE WELLHEAD DETAIL).
24. AQUIFER FLUSH SWING CHECK VALVE.
25. ROUTE 1" SAMPLE LINE FROM EXISTING MONITORING WELL TO INSIDE BUILDING. ROUTE SAMPLE LINE TO AVOID OTHER ABOVE
PEDESTAL OR WALL MOUNTED ENCLOSURES, AT-GRADE
HANDHOLES, AND PIPE SUPPORTS AS REQUIRED.
26. MOUNT CABLE TO MAXIMIZE ACCESS TO WELLHEAD.
COORDINATE LOCATION WITH OPERATION STAFF DURING
CONSTRUCTION.
27. INSTALL SHELF, COORDINATE LOCATION WITH OPERATIONS
STAFF.
28. SWING CHECK VALVE WITH WEIGHTED ARM.
#
REG I ST ERED PROFESS I ONA L ENG I NEER
ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 2:29:24 PM
R:\d1341485\11843A1013M800.rvt
13M01
CAMPUS OAKS ASR WELL
BUILDING PLAN 56
MECHANICAL
SMB
OB
MED
SCALE:
PLAN A 1/4" = 1'-0"
178
12"x10" RED
WELL ANNULUS
RECHARGE VALVE
TYP
MP034 (TYP)
2" ARV
BI-DIRECTIONAL
MAG METER
MODULATING RECHARGE
CONTROL VALVE
10" PRESSURE
REDUCING VALVE
10" H-STRAINER
10"x8" RED
12"x8" RED
PUMP
10" AS/AR
12" AS/AR
WD34-FCVX-30120
12" AS
WD34-FITX-30104
12" AS/AR
WD34-MOVX-30160
3/4" DRAIN LINE
W/ BALL VALVE (TYP)
FROM BOTTOM OF PIPE
PRESSURE TRANSMITTER
AND PRESSURE INDICATOR
PRESSURE TRANSMITTER AND
PRESSURE INDICATOR
WD34-FCVX-30150
WD34-PDIT-30151
WD34-PDIT-30151
10"X12" REDUCER
WD34-PIXX-30150
PRESSURE INDICATOR
PRESSURE DIFF W/ BYPASS
WD34-PIXX-30106
12" AS/AR
WD34-MOVX-30140
10" AF
SCREEN
1" SPARE NIPPLE AND FULLPORT BALL VALVE FROM
CENTERLINE SIDE OF PIPE.
CL 124.00
CL 120.54
10" AS
PUMP
12" SWING
CHECK VALVE
12" AS/AR NITROGEN
HOSE
PRESSURE TRANSMITTER
AND INDICATOR
2" ARV
2 13M03
WD34-PSHH-30107
PRESSURE SWITCH
HIGH
WD34-PITX-30102
WD34-PIXX-30102
3/4" SH
3/4" NAF
1 13M03
TYP
MC777
TYP
MC777
GENERAL NOTES:
1. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING OFFSET,
SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE THE PROCESS AND INSTRUMENTATION DIAGRAMS AND SPECIFICATION SECTION 15052- COMMON WORK RESULTS FOR GENERAL PIPING.
2. PROVIDE ISOLATION FLANGE KIT BETWEEN THE WELLHEAD AND ABOVE GROUND PIPING.
REG I ST ERED PROFESS I ONA L ENG I NEER
ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 2:29:27 PM
R:\d1341485\11843A1013M800.rvt
13M02
CAMPUS OAKS ASR WELL
BUILDING SECTIONS AND DETAILS 1 57
MECHANICAL
SMB
OB
MED
SCALE:
SECTION
13M01 3/8" = 1'-0"
B
SCALE:
SECTION
13M01 3/8" = 1'-0"
C
178
NITROGEN
TANK (TYP)
DHCV VCP CHLORINE ANALYZER
PANEL
FLUORIDE ANALYZER
PANEL
3 13M03
13 NITROGEN
TUBE
14 ROUTE 2 NITROGEN TUBES
TO FLOOR DRAIN TRENCH
THEN TO WELLHEAD
MONITORING WELL
PUMP CONTROLLER, MOUNT
ON WALL, SHELF, OR POST,
SEE TYPICAL DETAILS EM210
AND MP218
SPARE NITROGEN TANK
1/2" BACKFLOW PREVENTER
W/ WYE STRAINER
SAMPLE LINE FROM
12" AS/AR, SEE 13M01
TO BUILDING DRAIN LINE,
SEE PLUMBING PLAN
1/4" NITROGEN VENT
THROUGH WALL
1/2" SAM
1/2" SAM
VENT SEE PLUMBING PLAN
WD34-PEXX-30122
PRESSURE TRANSMITTER
M
S
WELL CASING
WELL COLUMN PIPE
3/4" PRELUBE, THROUGH PUMP
DISCHARGE HEAD ASSEMBLY
PRELUBE SOLENOID VALVE
FLOW SWITCH
MAG FLOW
METER
GLOBE VALVE
(TYP)
THROTTLING
NITROGEN HOSES, SEE
WELLHEAD DETAIL
ANNULAR SPACE
WD34-FITX-30105
WD34-FEXX-30113
1" PW
PRESSURE
REDUCING
VALVE
3/4" TRICKLE
5 13M09
WATER LEVEL GAUGE
WD3-PIXX-30105
1/2" SEAL
INSTALL 1" THREADED NIPPLE,
1" X 1/2" TEE AND 1" FULL PORT
BALL VALVE. INSTALL AIR AND
VACUUM RELEASE VALVE
OFF OF 1/2" TEE.
1/2" AIR AND VACUUM
RELEASE VALVE,
1/2" BALL VALVE AND PIPING
LEVEL TRANSDUCER
CORD GRIP AND SEAL
WD34-LITX-30100
2" SOUNDING TUBE
PLUG
2 1
10 3
4 12
GRAB
SAMPLE
2 9
3 5
16 TYP
8 7
6 8
4 9
16 TYP
10 5
7 3
10 2
1/2" SAM
GRAB
SAMPLE
4' - 6"
11 KEY NOTES:
1. FLUORIDE ANALYZER, ROUTE SAMPLE DRAIN AND OVERFLOW
TUBES TO DRAIN FUNNEL WITH 2 DIAMETER AIR GAP.
2. 1" PVC BACKER BOARD MOUNTED ON MASONRY WALL WITH
1/2" ANCHORS.
3. BALL VALVE (TYP).
4. DIAPHRAGM VALVE.
5. 0-40 GPM ROTAMETER.
6. AIR RELEASE VALVE.
7. PRESSURE GAUGE.
8. PRESSURE REDUCING VALVE.
9. 10" FILTER, 50 MICRON.
10. NEEDLE VALVE.
11. CHLORINE RESIDUAL ANALYZER, ROUTE SAMPLE DRAIN AND
OVERFLOW TUBES TO DRAIN FUNNEL WITH 2 DIAMETER AIR GAP.
12. pH SENSOR.
13. THREE "K" SIZE NITROGEN CYLINDERS, 1 DUTY + 2 SPARE, (228 SCF 9" DIA. x 51" TALL). SECURE TO WALL WITH PREFORMED CHANNEL CHAIN, OR OTHER ACCEPTABLE MEANS.
14. BASKI VENDOR CONTROL PANEL FOR DOWNHOLE FLOW CONTROL VALVE. ONLY A SCHEMATIC LAYOUT IS SHOWN. REFER TO
MANUFACTURER'S INSTALLATION MANUAL FOR LAYOUT, PIPE
SIZES, AND MATERIALS.
15. NOT USED.
16. INSTALL UNIONS OR VALVES WITH UNION CONNECTIONS AS
REQUIRED THROUGHOUT THE SAMPLE AND ANALYZER ASSEMBLIES
TO AID IN THE REMOVAL AND RE-ASSEMBLY OF VALVES AND
EQUIPMENT FOR MAINTENANCE.
#
GENERAL NOTES:
1. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING OFFSET,
SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE THE PROCESS AND INSTRUMENTATION DIAGRAMS AND SPECIFICATION SECTION 15052- COMMON WORK RESULTS FOR GENERAL PIPING.
REG I ST ERED PROFESS I ONA L ENG I NEER
ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 2:29:28 PM
R:\d1341485\11843A1013M800.rvt
13M03
CAMPUS OAKS ASR WELL
BUILDING SECTIONS AND DETAILS 2 58
MECHANICAL
SMB
OB
MED
SCALE:
SECTION
3/8" = 1'-0" 13M01
D
SCALE:
DETAIL
13M01 NO SCALE
1 SCALE:
DETAIL
13M01 NO SCALE
2 SCALE:
DETAIL
1/2" = 1'-0" 13M03
3 178
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:07:59AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 13M04
LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
MECHANICAL
11843A1013M004.dgn
PLUMBING SCHEDULES
PLUMBING ROUGH IN SCHEDULE
TAG NO.PW (IN.)HW (IN.) D/SS (IN.) VENT (IN.) FIXTURE DESCRIPTION WC 1-1/4" N/A 4" 3" WATER CLOSET (ADA ACCESSIBLE)
LAV 1/2" 1/2" 1-1/4" 1-1/2" LAVATORY (ADA ACCESSIBLE)
HXGR 1-1/4" N/A N/A N/A TANKLESS WATER HEATER (HB&ESEW)HXGR 3/4" N/A N/A N/A TANKLESS WATER HEATER (SINK)
CAMPUS OAKS ASR WELL
kbequette
WATER HEATER SCHEDULE
EQUIPMENT TAG AREA SERVED FLOW CAPACITY (GPM) TEMP. RISE (°F) ELEMENT (kW) MCA (Amps) VOLTAGE PHASE BASIS OF DESIGN NOTES WD05-HXGR-30002 RESTROOM .3 56 4.1 20 208 1 EEMAX EX4208T - WD37-HXGR-30401 CHEMICAL ROOM 23 21 72 87 480 3 HAWS 9327 1 NOTES:
1PROVIDE NEMA TYPE 4X CONTROL PANEL.
WATER HAMMER ARRESTOR SCHEDULE
SMITH MODEL * PDI SYMBOL ** FIXTURE UNIT RATING
5005 A 1-11
5010 B 12-325020 C 33-605030 D 61-1135040 E 114-1545050 F 155-330 * SMITH OR EQUAL ** PLUMBING DRAINAGE INSTITUTE "STANDARD PDI WH-201" 59 CG
4" MUD VALVE
IN SUMP INV 127.45 4" FCO 4" DR
REFER TO STRUCTURAL
FOR TRENCH DESIGN
(TYP)
4" FD
(IN TRENCH)
3" HD
(FOR ANALYZERS)
4" DR
4" DR
4" FD
3" VTR
3" VTR
3/4" PW
3/4" HOSE
VALVE
3/4" HOSE VALVE
1 1/2" PW
FROM 2" BACKFLOW
PREVENTER. REFER TO CIVIL
FOR CONTINUATION
WD05-HXGR-30002
TRICKLE FLOW WITH
ISOLATION VALVE AND
LEVEL GAUGE, SEE
SECTION 5/13M09
INV 127.29
MAG METER
PRELUBE WITH ISOLATION
BALL VALVE, FLOW SWITCH
AND SOLENOID VALVE, SEE
ELECTRICAL
2" PW
PRESSURE REDUCING VALVE
SET TO 80 PSI. INSTALL WYE
STRAINER UPSTREAM OF VALVE
3/4" PW
1 1/2" PW
WD37-HXGR-30401
1 1/2" PW
3/4" PW
TYP
HP640 (TYP)
2 1
TYP
(TYP) HP538
TYP
HP318 (TYP)
TYP
MA417
CL 100.20
CL 144.65
1/2" PW
(BELOW)
1 1/2" PW
CL 144.65
4" FD
3/4" FREEZELESS
WALL HYDRANT
TYP
MA417
WC
LAV
3" DR
INV 129.65
SK
INV 125.72
INV 125.52
CHEMICAL SUMP
REFER TO CIVIL
FOR CONTINUATION
4" FPW
TERMINATE 4" FPW LINE 2'-0"
ABOVE GRADE. PROVIDE END CAP
AT END OF PIPE FOR FUTURE USE
SLOPE
TO DRAIN
SLOPE
TO DRAIN
RIM 130.7
2" DR INV 128.95
2" DR
BELOW
CHEMICAL DRAIN
TRENCH
DRAIN TO SUMP
SLOPE
TO SUMP
3 INV 128.23
SLOPE TO DRAIN
GRADE BREAK
TYP
TYP
MP018
WD34-LEXX-30XX 4
INV 128.76
REFER TO CIVIL
FOR CONTINUATION
4" FD
3" V
1 1/2" PW 3" V
G
13M10
(TYP)
TYP
CY411
MP003
3" V
GENERAL NOTES:
1. PIPING SHALL BE FIELD ROUTED TO AVOID EQUIPMENT, PROCESS PIPING, AND OTHER ITEMS AS NECESSARY.
2. SLOPE ALL DRAIN LINES 2-1/2’’ AND BELOW AT A MINIMUM OF 1/4’’ PER FOOT IN THE DIRECTION OF FLOW.
3. SLOPE ALL DRAIN LINES 3’’ AND ABOVE AT A MINIMUM OF 1/8’’ PER FOOT IN THE DIRECTION OF FLOW.
4. ALL PIPING SHALL BE CONSTRUCTED FROM MATERIALS DEFINED IN SPECIFICATION 15052.
5. ALL DRAINS CONNECTED TO THE SANITARY SEWER SYSTEM TO CONTAIN P-TRAPS PER DETAILS HP220/TYP AND MA201/TYP.
6. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING
OFFSET, SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR
DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE
THE PROCESS AND INSTRUMENTATION DIAGRAMS AND
SPECIFICATION SECTION 15052-COMMON WORK RESULTS FOR
GENERAL PIPING.
7. REFER TO STRUCTURAL AND MECHANICAL FOR TRENCH DETAILS, SLOPING, AND PIPING. TRENCHES SHOWN ON THIS SHEET FRO
REFERENCE ONLY.
KEY NOTES:
1. SURFACE MOUNTED MECHANICAL TRAP PRIMER. PRIMER TO SERVE ALL DRAINS WITH P-TRAPS.
2. MAINTAIN 32’’ CLEARANCE AROUND EMERGENCY SHOWERHEAD.
3. MINIMUM 1.5% SLOPE BACK TO CHEMICAL SUMP WITHIN DEEPENED SLAB SECTION. REFER TO STRUCTURAL NOTES FOR MINIMUM
CLEARANCE AND OTHER REQUIREMENTS.
4. LEVEL SWITCH IN CHEMICAL SUMP.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 9:30:38 AM
R:\d1341489\11843A10013P800.rvt
13M05
CAMPUS OAKS ASR WELL
PLUMBING PLAN 60
MECHANICAL
CAG
KHB
WJS
SCALE:
PLAN E 1/4" = 1'-0"
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:08:28AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
CG
11843A1013M006.dgn
MECHANICAL 13M06
HVAC SCHEDULES 61
CAMPUS OAKS ASR WELL
WD37-HVAC-30105 ELECTRICAL ROOM - 90/67 48/34 55 54
NOTES:
1 2
3 4
THERMOSTAT PROVIDED BY MANUFACTURER.CONTROL SYSTEM SPECIFIED IN SECTION 15936- INSTRUMENTATION AND CONTROL DEVICES FOR HVAC.PROVIDE INTERNAL CONDENSATE LIFT PUMP ACCESSORY.PROVIDE CONDENSING UNIT SIZED PER VRF MANUFACTURER TO PROVIDE HEATING AND COOLING REQUIREMENTS AS INDICATED FOR ASSOCIATED FAN COIL UNITS 1,218 105 PER MFR PER MFR MERV 13 1 208 1 1.8 DAIKIN FXFQ48TVJU 1, 2, 3, 4 WD37-HVAC-30104 ELECTRICAL ROOM 1,165 - 105 90/67 PER MFR 36/28 55 PER MFR 40 MERV 13 1 208 1 1.5 DAIKIN FXFQ36TVJU 1, 2, 3, 4 WD37-HVAC-30103 ELECTRICAL ROOM
1,165 - 105 90/67 PER MFR 48/34 55 PER MFR 54 MERV 13 1 208 1 1.8 DAIKIN FXFQ48TVJU 1, 2, 3, 4 WD37-HVAC-30101 ELECTRICAL ROOM - - 105 - - - - - - 460 3 55.1 4
AIR CONDITIONING / HEAT PUMP SCHEDULE
EQUIPMENT TAG AREA SERVED
AIRFLOW
(CFM)
ESP
(IN. W.C.)
COOLING DATA FILTER DATA ELECTRICAL DATA
OA DB/WB BASIS OF DESIGN NOTES
(°F)
EAT DB/WB
(°F)
LAT DB/WB
(°F)
TOTAL / SENSIBLE CAPACITY
(MBH)
EFFICIENCY
THICKNESS
(IN.)
VOLTAGE PHASE
MCA
(AMPS)
MECHANICAL HEATING DATA
EAT DB/WB
(°F)
LAT DB/WB
(°F) (MBH)
TOTAL CAPACITY
WD37-HVAC-30102 ELECTRICAL ROOM
1,218 - 105 90/67 PER MFR 36/28
160
55 PER MFR
130
40 MERV 13 1 208 1 1.5 DAIKIN FXFQ36TVJU
DAIKIN RXYQ198XATJA
1, 2, 3, 4
ELECTRIC UNIT HEATER SCHEDULE
EQUIPMENT TAG AREA SERVED
HEATING CAPACITY
(kW)
AIRFLOW
(CFM)
MCA
(Amps)
VOLTAGE PHASE BASIS OF DESIGN NOTES
WD37-HEAT-30201 PUMP ROOM 3 700 5 480 3 TRIAD 234-U11N-0030U 1, 2, 3, 4 WD37-HEAT-30202 PUMP ROOM 3 700 5 480 3 TRIAD 234-U11N-0030U 1, 2, 3, 4 WD37-HEAT-30203 CHEMICAL ROOM 5 700 8 480 3 TRIAD 234-U11N-0050U 1, 2, 3, 4 WD37-HEAT-30204 ELECTRICAL ROOM 3 700 5 480 3 TRIAD 234-U11N-0030U 1, 2, 3, 4 NOTES:
1THERMOSTAT PROVIDED BY HEATER MANUFACTURER. THERMOSTAT SHALL BE LOCKED OUT AND NOT ALLOW HEATING ABOVE 55 DEGREES FAHRENHEIT. 2WALL MOUNTED.
3SIDE AIR DISCHARGE.
FAN SCHEDULE
EQUIPMENT TAG AREA SERVED FAN TYPE
AIR FLOW
(CFM)
ESP
(IN. W.C.)
FAN
RPM
NOISE
(SONES)
MOTOR DRIVE
TYPE
BASIS OF DESIGN NOTES
HP RPM V/PH/HZ ENCLOSURE
WD05-FANx-30303 RESTROOM TYPE 5 140 0.7 1050 4.5 0.128 (kW) 1050 115/60/1 ODP DIRECT GREENHECK SP-B150 5 WD37-FANx-30301 PUMP ROOM TYPE 4 700 0.35 1160 12.2 1/4 1160 460/60/3 TEFC DIRECT GREENHECK AER-E20C-603-B3 1, 2, 3, 4, 6, 7 WD37-FANx-30302 CHEMICAL ROOM TYPE 4 700 0.35 1160 12.2 1/4 1160 460/60/3 TEFC DIRECT GREENHECK AER-E20C-603-B3 1, 2, 3, 6, 7 NOTES:
1PROVIDE BIRD SCREEN.
2PROVIDE BACKDRAFT DAMPER BDD-3, COUNTERBALANCED FOR MINIMUM PRESSURE LOSS. 3PROVIDE DISCONNECT SWITCH AT FAN, NEMA TYPE 4X.
4PROVIDE THERMOSTAT AS SPECIFIED IN SECTION 15936.
5FAN SHALL BE INTERLOCKED WITH LIGHT SWITCH.
6PROVIDE HI-PRO POLYESTER COATING.7PROVIDE ACOUSTICAL LOUVER L-3 AS SPECIFIED IN SECTION 08910. jshaffer
T
T
700
CFM EA
11 TO
WD37-TSHX-30301
WD37-HEAT-30202
WD37-HEAT-30203
8 WD37-HEAT-30201 12 700
CFM OA 6 2
6"ø EA
WD05-FANX-30303
100
CFM EA
WD37-HEAT-30204
TO VRF SYSTEM
WD37-FANX-30301
TYP
HE350 (TYP)
TYP
HE520 (TYP)
TYP
(TYP) HE150
13 13
13 700
CFM EA
WD37-FANX-30302
13 700
CFM OA
9 TYP
HE620 (TYP)
(TYP)3
WD37-HVAC-30101
(TYP)7
5 WD37-HVAC-30103 WD37-HVAC-30105
10 4
TYP
HE166 (TYP)
2' - 2"
1 WD37-HVAC-30104 WD37-HVAC-30102
PUMP ROOM
CHEMICAL ROOM
GENERAL NOTES:
1. MOUNT THERMOSTATS AT 48” AFF AND LABEL WITH ITS
CONTROLLING DEVICE. THERMOSTAT LOCKBOXES TO BE
PROVIDED BY MECHANICAL CONTRACTOR.
2. DUCTWORK SERVING ELECTRICAL ROOM TO BE ALUMINUM PER
SECTION 16133. DO NOT ROUTE ABOVE ELECTRICAL EQUIPMENT.
3. ALL DUCTWORK AND SUPPORTS SHALL BE CONSTRUCTED PER
SMACNA. REFER TO SPECIFICATION SECTION 16133 FOR
ADDITIONAL REQUIREMENTS.
4. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING
OFFSET, SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR
DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE
THE PROCESS AND INSTRUMENTATION DIAGRAMS AND
SPECIFICATION SECTION 15052-COMMON WORK RESULTS FOR
GENERAL PIPING.
KEY NOTES:
1. 32’’x24’’ INTAKE LOUVER TYPE L-3 TO BE MOUNTED AT 8’-0’’ AFF.
2. BACKDRAFT DAMPER (BDD-3).
3. MANUFACTURER REQUIRED CLEARANCE. DO NOT BLOCK.
4. REFRIGERANT LINES. LINES WILL ENTER THE PUMP ROOM DOWN LOW THEN RISE TO BE ROUTED UNDER THE HARD CEILING. FIELD ROUTE TO FAN COIL UNITS IN ELECTRICAL ROOM. AVOID RUNNING LIQUID SIDE PIPE OVER ELECTRICAL EQUIPMENT. INSULATE ALL PIPING PER SPECIFICATIONS.
5. HEAT PUMP TYPE CONDENSING UNIT SERVING VRF. CONTRACTOR TO SUBMIT ANCHORAGE CALCULATIONS PER SPECIFICATION 01850.
6. 16''x8'' EXHAUST BRICK VENT TO BE MOUNTED AT 9’-4’’ AFF.
7. INDOOR VRF FAN COIL UNIT TO BE MOUNTED UNDER CEILING PER MANUFACTURER STANDARDS. SUBMIT SHOP DRAWINGS AND
CALCULATIONS FOR INDOOR UNIT SUPPORTS PER SPECIFICATION 01850. CONTRACTOR TO COORDINATE WITH TRUSS MANUFACTURER FOR ADDITIONAL LOADING. DO NOT PLACE ABOVE ELECTRICAL
EQUIPMENT.
8. WALL MOUNTED EXHAUST FAN AND CORRESPONDING ACOUSTICAL LOUVER TYPE L-3 TO BE MOUNTED IN WALL AT 2'-0" AFF PROVIDE FAN WITH GUARD.
9. ROUTE CONDENSATE PIPING OUT OF BUILDING AND INTO DRY WELL. SLOPE CONDENSATE DRAIN AT 1/8'' PER FOOT IN THE
DIRECTION OF FLOW.
10. 1'' SCH 40 PVC CONDENSATE DRAIN PIPE. INSULATE PER
SPECIFICATIONS.
11. WALL MOUNTED EXHAUST FAN AND CORRESPONDING ACOUSTICAL LOUVER TYPE L-3 TO BE MOUNTED IN WALL AT 7'-4" AFF PROVIDE FAN WITH GUARD.
12. 32"x24" INTAKE LOUVER TYPE L-3 TO BE MOUNTED AT 2'-0" AFF.
13. WALL MOUNTED ELECTRIC UNIT HEATER. MOUNT HEATER AT
8’-0’’ AFF.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 9:32:19 AM
R:\d1341488\11843A1013H800.rvt
13M07
CAMPUS OAKS ASR WELL
HVAC PLAN 62
MECHANICAL
CAG
KHB
WJS
SCALE:
PLAN K 1/4" = 1'-0"
1 1/28/2022 WJS DC003
(TYP)
THERMOSTAT
TYPE L-3 (TYP)ACOUSTICAL LOUVER
T
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:08:05AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
11843A1013M008.dgn
CFM EA
100
CFM EA
700
RESTROOM
WD05-FANx-30303 WD37-FANx-30301
T
CFM SA
1,165
T
CFM OA
700
CFM EA
700
CFM OA
700
WD37-HVAC-30101
WD37-HEAT-30204
T
T
WD37-HEAT-30203
WD05-FANx-30302
WD37-HEAT-30202 WD37-HEAT-30201
T
PUMP ROOM
CHEMICAL ROOM
13M08
HVAC AIRFLOW SCHEMATIC
CFM SA
1,218
CFM SA
1,218
CFM SA
1,165
WD37-HVAC-30102 WD37-HVAC-30103 WD37-HVAC-30104 WD37-HVAC-30105
MECHANICAL
CAMPUS OAKS ASR WELL
jshaffer
ROOM
ELECTRICAL
63 CFM INFILTRATION
100
CG
6 '-21/2"
3'-2"
2'-8"
2'-2" 1'-9"
1"
6"
2"
6"
3"
4 1/2"
4"
1'-0"
1'-4"
2'-2" 6"
1'-0"
6"
6"MIN
6"MIN
BELOW GRADE (TYP)MIN 3" EDGE DISTANCE
MAX 40.24"
2'-0"
1'-0"
22.5°
22.5°
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:12-DEC-20242:06:21PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 13M09
LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
TLR
MECHANICAL
WELLHEAD DETAILS
11843A1013M009.dgn
GENERAL NOTES:
3/8"
3/8"
SST WELLHEAD
FABRICATED 316L
DISCHARGE HEAD
FABRICATED 304 SST PUMP
SST WELLHEAD
FABRICATED 304
3/8"
ASR WELL PUMP
3/4" SST NIPPLE3/4" SST TO 3/4" POLY CONNECTOR3/4" TF-POLY SST
POLY
3/4" SST NIPPLE
1/4" V307
MODEL IPG45-WLSS)
(AMERICAN GRANBY
WATER LEVEL GAUGE
5 6" = 1'-0"
11843A1013M400
TRICKLE FLOW CONNECTION
13'-4"
WELL PUMP MOTOR
12" AR
CL +3.50
CL +2.50
WELD REPLACEMENT WELLHEADCUT EX-CASING AND FIELD
WELLHEAD
EXISTING
WELLHEAD
CL +1.25
10" AS
T.O.W. +14.00
EX FIN GR
ELEV 0.00TOC DATUM
SEE STRUCTURALBUILDING FOUNDATION,
M- L
13M01
11843A1013M400
1" = 1'-0"
EX FIN GR
VALVE W/ SST CAP
SST SCHRADER
64 EL +11.86
ANNULAR RECHARGE)
(AQUIFER STORAGE,
SEE CIVIL/STRUCTURALBUILDING ELEVATION,
SECTION 11313 VERTICAL TURBINE PUMPS12" PUMP COLUMN, SEE SPECIFICATION CONCRETE BUILDING SLAB AND WELLHEADCONDUCTOR CASING ENOUGH TO INSTALL EXCAVATE AND EXPOSE EXISTING #5 @ 8" O.C.
1/2" BJF
PUMP DISCHARGE)(AQUIFER RECOVERY,
ALL OTHER ARE SHOP WELDSFIELD WELD TO EXISTING CASING,
EX-304 SST CASING
SST WELDOLET1 1/2" NPT 304
10" 304 SST
SECTION 05120 STRUCTURAL STEELFABRICATED WELLHEAD IN SPECIFICATION INSPECTION REQUIREMENTS FOR SEE FABRICATION, WELDING, AND 5 AND TUBE EXTENSIONS (TYP)WELD 22.25 DEG BENDS CUT EX-TUBES AND FIELD 3/4" TF-SST
3/4" BALL VALVE
1/4 SST PLUG
3/4" SST TEE
EXISTING CONDUCTOR CASING, WHICH EVER IS LARGER.ENCASEMENT, 42" DIAMETER OR MATCH CYLINDRICAL CONCRETE WELLHEAD MECHANICAL DWGSFOR ARV, SEE SST WELDOLET1-1/2" NPT 304
M
1" = 1'-0"
11843A1013M400
WELLHEAD - N 1" = 1'-0" 11843A1013M400 -WELLHEAD (TYP A & B) P 1" = 1'-0" 11843A1013M400 -WELLHEAD (TYP A & B)
EXISTING CASING
INSTALLATION INSTRUCTIONSMANUFACTURER'S PRELUBE, REFER TO PUMP 12" COLUMN PIPEHEAD W/ 18" FLANGE AND12" WELL PUMP DISCHARGE SST FLANGE10" AS 304
PUMP HEAD & WELLHEAD
PUMPHEAD
TRICKLE FLOW CONNECTION
3" MIN COVER
COUPLINGS, TYPICALSST NIPPLES AND
LENGTH OF TUBINGRECOMMENDATIONS, TYPICAL FOR THESPACERS PER MANUFACTURER'SSST BAND CLAMPS AND PROTECTIVESTRAP TUBING TO COLUMN PIPE USING 10" X 12" REDUCER, WELDED10" PUMP COLUMN
I.D., TYPICAL10" PIPE FLANGE O.D. AND 20" CASINGBETWEEN TRICKLE FLOW CONNECTIONCENTER PENETRATION EQUALLY FLANGE O.D. 15" MAX.UNDERSIDE OF WELLHEAD,10" PIPE FLANGE BOLTED TO
WELLHEAD
WELLHEAD
FIELDVERIFYFIELDVERIFY
PUMPHEAD
18" CASING
FITTING FLANGE
18" SST WELL HEAD
FLANGE
18" PUMP HEAD
MAX O.D. 15"
10" PIPE FLANGE,
2 13M03
NOTE:
FABRICATIONPRIOR TO PROCUREMENT ANDLOCATIONS, AND ORIENTATIONWALL THICKNESS, MATERIALS,FIELD VERIFY ALL PIPE DIAMETERS,
CAMPUS OAKS ASR WELL
13M09
13M03, 13M09
FLANGE KIT DETAILISOLATION JOINT
TYP
CP175
P- N- 12" COLUMN PIPE FLANGE O.D. 15" FROM COLUMN PIPE TO PUMP HEAD, 10" FLANGE ON 10" X 12" REDUCER A-778 TYPE 304 SST CASING EX-20" I.D. 3/8" WALL ASTM ASTM A-139 GRADE B STEEL EX-36" O.D. X 3/8" WALL ENCASEMENT CONCRETE WELLHEAD TRANSDUCER PRESSURE W/ WATER LEVEL SST SOUNDING TUBE EX-2" SCH 40 304 PUMP DISCHARGE, TYPICAL SO THAT TUBE IS NOT UNDER EXTEND TUBE AND BEND OUTWARD GRAVEL FILL PIPE EX-3" SCH 40 BSP LOCATION BY PUMP SUPPLIER SHAFT PRELUBE WATER, LOCATION BY PUMP SUPPLIER MECHANICAL SEAL WATER, FLANGE O.D. AND CASING I.D., TYPICALEQUALLY BETWEEN COLUMN PIPEDETAIL 5/-. CENTER PENETRATIONWATER LEVEL GAUGE, SEETRICKLE FLOW AND WATER 10" AS
ANNULAR RECHARGE)
(AQUIFER STORAGE,
13M09 THE EXISTING WELL
TOP VIEW OF
(FOR BASKI DOWNHOLE CONTROL VALVE)BOTTOM TO MEET COUPLINGB.C. 3/8" NPT THREADS FROM[2] 3/8" COUPLINGS ON 8.81" 12" AR
A-778 TYPE 304 SST CASING20" I.D. X 3/8" WALL ASTM
(2) 1/4" NITROGEN
1/2" SEAL
3/4" PRELUBE
3/4" TRICKLE
20" I.D. X 3/8" WALL ASTM A-778 TYPE 304 SST CASING
HOOPS @ 12" O.C.#4 ROUND
NITRONIX TAPERED
A-778 TYPE 304 SST CASINGEX - 20" I.D. X 3/8" WALL ASTM GRADE B STEEL CONDUCTOR CASINGEX - 36" O.D. X 3/8" WALL ASTM A-139 SOUNDING TUBE EX-2" SCH 40 304 SST
SST CASING, FIELD VERIFYWALL ASTM A-778 TYPE 304MATCH EXISTING 20" I.D. X 3/8" DRAWINGS.ACCORDANCE WITH THE REQUIREMENTS DESCRIBED ON THE CONCRETE. THE CONCRETE AND REINFORCING SHALL BE IN PROVIDE 0.5-INCH MINIMUM CHAMFER ALL EXPOSED EDGES OF THE CASING AND SUPPORTED BY THE GROUT AROUND THE CASING. SHOWN, SHALL BE FULLY SEATED TO THE TOP OF THE SURFACE ENCASEMENT. AROUND THE FINISHED WELLHEAD ASSEMBLY AS
7. THE CONTRACTOR SHALL PROVIDE THE REINFORCED CONCRETE SHALL BE NSF APPROVED FOR POTABLE WATER USE.AIR IS CHARGED THROUGH THE SCHRADER VALVE. ALL MATERIALS TEE ON THE PUMP BASE. OR AS A BUBBLER TYPE INDICATOR WHEN A MANUAL TAPE THAT CAN BE DROPPED THROUGH THE TOP OF THE SHALL SERVE AS A BACKUP MEANS OF MEASURING WATER LEVEL VIA WATER VIA TRICKLE FLOW (TF) CONNECTION INTO THE WELL, AND TUBING SHALL SERVE A DUAL PURPOSE OF DIRECTING CHLORINATED SPACING TO A DEPTH OF 1 FOOT ABOVE THE BOWL ASSEMBLY. THE STRAPPED TO THE PUMP COLUMN WITH SST HOSE CLAMPS AT 10 FT
6. PROVIDE 0.75-INCH DIAMETER SEMI-RIGID POLYETHYLENE TUBING ON THESE DRAWINGS. CONNECTIONS AND APPURTENANCES AS SHOWN AND AS SPECIFIED MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL SPECIAL
5. INSTALL THE VERTICAL TURBINE PUMP AS PER THE
THE PLUG.PROCESS. PROMPTLY REMOVE ANY MATERIALS THAT FALL IN ABOVE ENTRY OF FOREIGN MATERIALS DURING THE CONSTRUCTION ATMOSPHERE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY INFLATABLE PLUG NEAR THE SURFACE WHEN OPEN TO MATERIALS AT ALL TIMES DURING CONSTRUCTION BY THE USE OF A
4. THE WELL SHALL BE PROTECTED FROM THE ENTRY OF FOREIGN MATERIALS AND COMPONENTS. REPAIR, AND REPLACE ANY UNSATISFACTORY WELDS OR DAMAGED SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE TO REMOVE, INSPECTIONS PER THE CONTRACT SCOPE OF WORK AND TECHNICAL SUBJECT TO FIELD WELDING AND SHOP WELDING PROCEDURES AND STEEL, SHALL BE PERFORMED BY A CERTIFIED WELDER AND IS FABRICATED WELLHEAD SHALL BE CONSIDERED TO BE STRUCTURAL
3. THE FIELD WELDING TO THE EXISTING WELLHEAD AND THE NEW PROVIDE MINIMUM COVER OVER BAR AND CHAMFER EDGE. REINFORCED CONCRETE ENCASEMENT AROUND NEW WELLHEAD. EXISTING SOUNDING TUBE AND GRAVEL FILL PIPE. INSTALL INSTRUMENT. MATCH NEW PIPE THICKNESS, AND MATERIAL TO REMOVAL OF THE FLANGED FITTINGS, BOLTS, VALVES, AND LEVEL FROM UNDER THE CASING FLANGE AS TO ENABLE THE EASY BEND OUTWARD FROM THE CENTER OF THE WELL HEAD AND OUT GRAVEL FILL PIPE AND FIELD WELD ON NEW FABRICATED TUBES TO TO EXISTING SST CASING. CUT EXISTING SOUNDING TUBE AND REQUIREMENTS. MATCH NEW SST SIZE, THICKNESS, AND MATERIAL COORDINATED WITH THE PUMP MOUNTING AND PIPING ORIENTATION PLACEMENT OF THE TOP FLANGE AND THE BOLT HOLES SHALL BE SHALL BE WELDED PLUMB AND TRUE. THE SIZE DIMENSIONS AND WITH A CLEAN LEVEL/PLUMB EDGE. THE FABRICATED WELLHEAD SLAB AND WELLHEAD. CUT EXISTING SST CASING TO ELEVATION CONCRETE ENCASEMENT ENOUGH TO INSTALL CONCRETE BUILDING EXPOSE AND DEMOLISH EXISTING CONDUCTOR CASING AND ENCASEMENT EXTEND TO APPROXIMATELY EXISTING GRADE. CARBON STEEL CONDUCTOR CASING AND CONCRETE SEAL AND GRAVEL FILL TUBE EXTENDS ABOVE EXISTING GRADE. THE EXISTING
2. THE EXISTING STAINLESS STEEL WELL CASING, SOUNDING TUBE, AND LUHDORFF & SCALMANINI CONSULTING ENGINEERS, JANUARY 2024WELL CONSTRUCTION SEE "CAMPUS OAKS WELL AS-BUILTS, BY
1. THE EXISTING WELL WAS CONSTRUCTED BY OTHERS. FOR EXISTING 10 eparker
10- NOT TO SCALE
11843A1013M601/602
EXISTING WELL - TOP VIEW EXISTING WELL - NORTH ELEVATION 304 SST
WALL ASTM A-778 TYPEWELL CASING 12" X 3/8"
ASTM A-139 GRADE B STEEL
36" O.D. X 3/8" WALL
CONDUCTOR CASING
EXISTING GRADE
POSSIBLE 4" ABOVE
AVOID WELD IF
GRADE
ABOVE EXISTING
POSSIBLE 18"
AVOID WELD IF
BALL SWING CHECK.
INTO DISTRIBUTION, THREADED SST 3/4"
CHECK VALVE TO PREVENT BACKFLOW
RM
SHALL BE PICKLED AND PASSIVATED.MINIMUM. ALL STAINLESS STEEL WELDS WELDING SHOULD BE KEPT TO A CONTROLLED CONDITIONS. FIELD IN THE SHOP UNDER IDEAL AND PERFORM AS MANY WELDS AS POSSIBLE AND WELDS SHOULD BE INSPECTED. QUALIFIED WELDERS SHOULD BE USED, ARE STRUCTURAL COMPONENTS. NOTE: THE WELL HEAD AND PUMP HEAD COLUMN PIPE ARE PLUMB.WELLHEAD, LINESHAFT ANDLEVEL EDGE SO THAT THECASING WITH A STRAIGHTSHALL CUT EXISTING WELLNOTE: CONTRACTOR GRAVEL FILL PIPEEX-3" SCH 40 BSP
PUMP DISCHARGE)
(AQUIFER RECOVERY
SOUNDING TUBE
2" SCH 40 304 SST
GRAVEL FILL PIPE
3" SCH 40 BSP
REG I ST ERED PROFESS I ONA L ENG I NEER ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
F
13M10
1 3
4" V
11 CHEMICAL ROOM
5 9
2" SH
G
13M10
10 4
13 12
15 3/4" PW
3/4" SW
16 TANK FILL
3/4" NAF
3/4" SH 3/4" V
16" PW
6 18
3" OF
H
13M10
17 2" SH
14 2
19 CHEMICAL ROOM
16"x12" RED
4" V
2" SH
CL 141.39
3 6
13 16" PW
5 8
3/4" SW
3/4" NAF
3/4" V
10 TANK FILL
PRV
16 16
3/4" SH
1/2 NAF
1/2 SH
11 3" OF
1 17
9 7
6 SLOPE VENT PIPES TO
DRAIN TO TANK, 1/4" PER
FOOT, TYPICAL
20 SLOPE TO DRAIN
SLOPE TO DRAIN
SLOPE TO DRAIN
GENERAL NOTES:
1. SEE CIVIL FOR PIPING CONTINUATIONS
2. NOT ALL REQUIRED PIPE SUPPORTS ARE SHOWN.
3. ALL PIPE SUPPORTS WITHIN THE CHEMICAL ROOM SHALL BE FRP, UNLESS OTHERWISE NOTED. WALL PIPE SUPPORTS PER MP218/TYP, FLOOR PIPE SUPPORTS PER MP034/TYP, AND VERTICAL PIPE
SUPPORTS PER MP042/TYP.
4. ALL PIPE SUPPORTS USED FOR CHEMICAL SERVICE TO USE
CUSHION STRIPS BY ANVIL #AS 3792 OR EQUAL.
5. ALL BALL VALVES USED FOR SODIUM HYPOCHLORITE SERVICE SHALL BE VENTED BALL TYPE.
KEY NOTES:
1. 1,000 GALLON DOUBLE CONTAINED SODIUM HYPOCHLORITE
TANK PER SPEC 13208
2. EMERGENCY SHOWER & EYEWASH STATION PER HP640/TYP SEE PLUMBING PLAN, DWG 13M05
3. TANK VENT ROUTED THROUGH WALL PER P302/TYP, TERMINATE AT A 45 DEGREE ANGLE WITH BIRD SCREEN
4. LEVEL INSTRUMENT
5. SODIUM HYPOCHLORITE DUAL PUMP SKID PER SPEC 11242
6. 2" VENTED BALL VALVE
7. 2" BALL CHECK VALVE
8. BACKFLOW PREVENTER, DIRECT DRAIN TO FLOOR DRAIN BELOW
9. TANK FILL 2" QUICK DISCONNECT HOSE COUPLING WITH CAP ANGLED DOWNWARD 22 DEGREES, VENTED BALL VALVE, AND
BALL CHECK VALVE SUPPORTED FROM FLOOR
10. 3" OVERFLOW, ROUTE PIPING TO SUMP
11. FLEXIBLE FITTING PER TANK MANUFACTURER.
12. WATER SOFTENER PER KINETICO, MODEL S650XP AND BRINE TANK MODEL 7202
13. PACKAGED FLUORIDE DOSING SKID PER SPEC 11249
14. INSTANT WATER HEATER. SEE PLUMBING PLAN, DWG 13M05.
15. UTILITY SINK
16. ZURN 6" WIDE TRENCH DRAIN #ZF806-HDS-BDE WITH STAINLESS STEEL TOP FRAME AND GRATING COVER. TRANSITION FROM
PVC PIPE TO PFA TUBING IN TRENCH
17. REVERSE LEVEL FLOAT GAUGE
18. FRP GRATING COVER FOR SUMP, TRAFFIC RATED.
19. TANK DRAIN TO BE LOCATED AT THE BOTTOM OF THE TANK TO ALLOW FULL DRAINAGE. CUT NOTCH OUT OF CONCRETE PAD
AND ADJUST REBAR TO AVOID CONFLICTS.
20. PRIOR TO INSTALLING CONCRETE TANK PAD, VERIFY WITH PUMP
CHEMICAL PUMP MANUFACTURER AND SUPPLIER THAT MINIMUM
LIQUID LEVEL OF TANK MEETS MINIMUM NET POSITIVE SUCTION HEAD REQUIRED FOR CHEMICAL FEED PUMPS. RAISE TANK PAD
IF REQUIRED.
#
3/4" SW
1" PW
12 TYP
P302
2 15
14 1 1/2" PW
2" PW
1/2" PW
1/2" NAF 1/2" SH
16 1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 2:29:32 PM
R:\d1341485\11843A1013M800.rvt
13M10
CAMPUS OAKS ASR WELL
CHEMICAL ROOM 65
MECHANICAL
RM
OB
SKG
SCALE:
ENLARGED PLAN
13M01 3/8" = 1'-0"
E
SCALE:
SECTION
1/4" = 1'-0" 13M10
F
SCALE:
SECTION
1/4" = 1'-0" 13M10
G
SCALE:
SECTION
1" = 10'-0" 13M10
H
178
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:11-DEC-20243:00:54PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 13M11
LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
TLR
MECHANICAL
11843A1013M011.dgn
GENERAL NOTES:
eparker
CAMPUS OAKS - WELL PROFILE
DRAWINGS.ACCORDANCE WITH THE REQUIREMENTS DESCRIBED ON THE CONCRETE. THE CONCRETE AND REINFORCING SHALL BE IN PROVIDE 0.5-INCH MINIMUM CHAMFER ALL EXPOSED EDGES OF THE CASING AND SUPPORTED BY THE GROUT AROUND THE CASING. SHOWN, SHALL BE FULLY SEATED TO THE TOP OF THE SURFACE ENCASEMENT. AROUND THE FINISHED WELLHEAD ASSEMBLY AS
7. THE CONTRACTOR SHALL PROVIDE THE REINFORCED CONCRETE SHALL BE NSF APPROVED FOR POTABLE WATER USE.AIR IS CHARGED THROUGH THE SCHRADER VALVE. ALL MATERIALS TEE ON THE PUMP BASE. OR AS A BUBBLER TYPE INDICATOR WHEN A MANUAL TAPE THAT CAN BE DROPPED THROUGH THE TOP OF THE SHALL SERVE AS A BACKUP MEANS OF MEASURING WATER LEVEL VIA WATER VIA TRICKLE FLOW (TF) CONNECTION INTO THE WELL, AND TUBING SHALL SERVE A DUAL PURPOSE OF DIRECTING CHLORINATED SPACING TO A DEPTH OF 1 FOOT ABOVE THE BOWL ASSEMBLY. THE STRAPPED TO THE PUMP COLUMN WITH SST HOSE CLAMPS AT 10 FT
6. PROVIDE 0.75-INCH DIAMETER SEMI-RIGID POLYETHYLENE TUBING ON THESE DRAWINGS. CONNECTIONS AND APPURTENANCES AS SHOWN AND AS SPECIFIED MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL SPECIAL
5. INSTALL THE VERTICAL TURBINE PUMP AS PER THE
THE PLUG.PROCESS. PROMPTLY REMOVE ANY MATERIALS THAT FALL IN ABOVE ENTRY OF FOREIGN MATERIALS DURING THE CONSTRUCTION ATMOSPHERE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY INFLATABLE PLUG NEAR THE SURFACE WHEN OPEN TO MATERIALS AT ALL TIMES DURING CONSTRUCTION BY THE USE OF A
4. THE WELL SHALL BE PROTECTED FROM THE ENTRY OF FOREIGN MATERIALS AND COMPONENTS. REPAIR, AND REPLACE ANY UNSATISFACTORY WELDS OR DAMAGED SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE TO REMOVE, INSPECTIONS PER THE CONTRACT SCOPE OF WORK AND TECHNICAL SUBJECT TO FIELD WELDING AND SHOP WELDING PROCEDURES AND STEEL, SHALL BE PERFORMED BY A CERTIFIED WELDER AND IS FABRICATED WELLHEAD SHALL BE CONSIDERED TO BE STRUCTURAL
3. THE FIELD WELDING TO THE EXISTING WELLHEAD AND THE NEW EDGE. WELLHEAD. PROVIDE MINIMUM COVER OVER BAR AND CHAMFER INSTALL REINFORCED CONCRETE ENCASEMENT AROUND NEW AND MATERIAL TO EXISTING SOUNDING TUBE AND GRAVEL FILL PIPE. VALVES, AND LEVEL INSTRUMENT. MATCH NEW PIPE, THICKNESS, ENABLE THE EASY REMOVAL OF THE FLANGED FITTINGS, BOLTS, WELL HEAD AND OUT FROM UNDER THE CASING FLANGE AS TO FABRICATED TUBES TO BEND OUTWARD FROM THE CENTER OF THE SOUNDING TUBE AND GRAVEL FILL PIPES AND FIELD WELD ON NEW THICKNESS, AND MATERIAL TO EXISTING SST CASING. CUT EXISTING REQUIREMENTS. FIELD VERIFY AND MATCH NEW SST SIZE, COORDINATED WITH THE PUMP MOUNTING AND PIPING ORIENTATION PLACEMENT OF THE TOP ND THE BOLT HOLES SHALL BE SHALL BE WELDED PLUMB AND TRUE. THE SIZE DIMENSIONS AND WITH A CLEAN LEVEL/PLUMB EDGE. THE FABRICATED WELLHEAD SLAB AND WELLHEAD. CUT EXISTING SST CASING TO ELEVATION CONCRETE ENCASEMENT ENOUGH TO INSTALL CONCRETE BUILDING EXPOSE AND DEMOLISH EXISTING CONDUCTOR CASING AND ENCASEMENT EXTEND TO APPROXIMATELY EXISTING GRADE. CARBON STEEL CONDUCTOR CASING AND CONCRETE SEAL AND GRAVEL FILL TUBE EXTENDS ABOVE EXISTING GRADE. THE EXISTING
2. THE EXISTING STAINLESS STEEL WELL CASING, SOUNDING TUBE, AND LUHDORFF & SCALMANINI CONSULTING ENGINEERS, JANUARY 2024WELL CONSTRUCTION SEE "CAMPUS OAKS WELL AS-BUILTS, BY
1. THE EXISTING WELL WAS CONSTRUCTED BY OTHERS. FOR EXISTING RM -6 11843A1013M301
CAMPUS OAKS WELL 13
NOT TO SCALE
OUTER DIAMETER OF 17.5".INSTALLED WITHIN THE CASING. THE 10" FOOT VALVE HAS A FLANGE CASING, AS WELL AS CONFIRM THAT THE 10" FOOT VALVE CAN BE SHALL CONFIRM THE INSIDE DIAMETER & ROUNDNESS OF THE WELL DIAMETER & LENGTH OF THE 10" FOOT VALVE ASSEMBLY. THIS TEST CASING BY PASSING A FULL-SCALE DUMMY GAGE WITH THE OUTER
6. CONTRACTOR SHALL VERIFY THE INTERNAL DIAMETER OF THE WELL SUBSTITUTED SUBJECT TO APPROVAL OF THE ENGINEER.ADVANCE PRODUCTS & SYSTEMS, LAFAYETTE, LA MAY BE POLYETHYLENE AND STAINLESS STEEL AS MANUFACTURED BY
5. COMMERCIALLY AVAILABLE CENTRALIZERS MADE OF
THE R.O. RELIABILITY WELL PUMP COLUMN PIPING.
4. CENTRALIZERS SHALL ALSO BE USED FOR THE INSTALLATION OF CLEAR CASING 1/2" ON ALL SIDES. SPACING ON PUMP COLUMN FLANGES. CENTRALIZERS SHALL
3. PROVIDE CENTRALIZER AT BOTTOM FLANGE AT PUMP AND AT 20' SST PIPING REQUIREMENTS.
2. SEE SCHEDULE, (SHEET 00GM05) AND PIPE SPECIFICATIONS FOR SPECIFICATIONS.
1. SEE VALVE TYPE SCHEDULE, (SHEET 00GM04) AND VALVE NOTES:
AS-BUILT WELL PROFILE
COMW-A
COMW-B
COMW-C BTTM & FLTR PAC 415' BTTM 355' BTTM & SCRN 295' FLTR PAC 275' FLTR PAC 300' SCRN 345' SCRN 330' FLTR PAC 319' SCRN 390' SCRN 405' FLTR PAC 378' Campus Oaks Well 13 2.5" Dia. Sch 80 PVC, typical all FLTR PAC 359' SCRN 280' 102.9' BGS Static Water Level 201.6' BGS Pumped Water Level, (98.7 ft Drawdown @ 2,200 gpm) 211.6' BGS Regional Adjustment 241.6' BGS Minimum Submergence 251.6' BGS Baski Downhole Control Valve 2.5' AGS Top Flange of Well Casing 0.0' BGS/AGS Existing Grade 3.5' AGS CL Discharge Head 256.6' BGS Straight Column Pipe 267.1' BGS Pump Bowls 272.1' BGS Straight Column Pipe 273.6' BGS Foot Check Valve 276.6' BGS Cone Strainer Submersible sample pump Level sensor
REG I ST ERED PROFESS I ONA L ENG I NEER ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
FLANGE 66
4 '-0"
4'-0"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20242:03:42PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 13M12
LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
DPF
MECHANICAL
11843A1013M012.dgn
SECTIONS AND DETAILS 67
S- GENERAL NOTES:
CAMPUS OAKS - MONITORING WELL
eparker
11843A1013M402
1' = 1 1/2"
S- 11843A1013M402 1' = 1 1/2" T- R 1' = 1 1/2" 11843A1013M402
T- EQUIPMENT REMOVAL, TYP WIRE AND TUBING TO FACILITE PROVIDE EXTRA LENGTH OF PER PUMP SUPPLIER, TYPDISCHARGE HOSESAMPLE PUMPPVC CASING, TYPEX 2.5" SCH 40LOCKING COVERCASING W/ HINGEDEX 16" STEEL GROUND, TYPSST ABOVE1" SAMPLE,
EACH 2.5" MONITORING WELL16" STL CASING, WITH THREEEX - NESTED MONITORING WELL,
EX TRAFFIC BOLLARDS, TYP
EX CONCRETE HOUSEKEEPING PAD
1" SPARE SAMPLE LINE
PREFORMED CHANNEL PIPE SUPPORT, TYP
BELOW GROUND, TYP1" SAMPLE SCH 80 PVC
TYP
MP218
EX GRADE
EX 16" STEEL CASING
EX 2.5" SCH 40 PVC CASING, TYP
HOUSEKEEPING PADEX CONCRETE
LOCATIONS AND DEPTHSPUMP AND LEVEL SENSORSEE P&ID DRAWINGS FOR
CONDUIT
CONDUITS TO PUMP ROOMSAMPLE TO AIR-GAP STRUCTURE
1" SAM
PIPE SUPPORT, TYPPREFORMED CHANNEL
EX GRADE
HOUSEKEEPING PADEX CONCRETE
1" SAM
CONDUIT, TYP
1" SAM
(TYP)
AIR-GAP STRUCTURESAMPLE TO
EX 16" STEEL CASING
1" SPARE SAMPLE LINEPIPE SUPPORT, TYPPREFORMED CHANNELBALL VALVE, TYPSST FULL PORT
TOP FLANGE
1 13C02
11843A1013M603
1 13C02
11843A1013M603
MONITORING SAMPLE LINE
DM
TYP
EM211
(SIM)
TERMINAL BOX
REFER TO ELECTRICAL SPECIFICATIONSCONDUIT BELOW GROUND, TYP.
SINGLE RECEPTACLES
BELOW GROUND, TYP1" SAMPLE SCH 80 PVC
TERMINAL BOX
REFER TO ELECTRICAL SPECIFICATIONSABOVE GROUND CONDUITREFER TO ELECTRICAL SPECIFICATIONSBELOW GROUND CONDUIT
SAMPLE TO PUMP ROOM
REFER TO ELECTRICAL SPECIFICATIONSABOVE GROUND CONDUITREFER TO ELECTRICAL SPECIFICATIONSBELOW GROUND CONDUIT
TERMINAL BOX
SINGLE RECEPTACLES
208V/1-P/60Hz, OR EQUAL.INC. THE PUMP SHALL BE GRUNDFOS MODEL 22SQE07-120, FT OF BORELINE HOSE AS MANUFACTURED BY HOSE SOLUTIONS, COMPLETE WITH 200 FT OF SUBMERSIBLE POWER CABLE AND 150 BE RATED AT 8 GPM AT 140 FT TDH, AND SHALL BE PROVIDED DEPTH OF 150 FT BLS USING 1" BORELINE HOSE. THE PUMP SHALL
5. PROVIDE A 3/4 HP SST SUBMERSIBLE SAMPLE PUMP, TO BE SET AT A MEASUREMENTS.) REMOVED TO PROVIDE ACCESS FOR PERIODIC WATER LEVEL NPT THREADED AND PLUGGED HOLE AS SHOWN. (THE PLUG CAN BE NPT THREADED NIPPLE CONNECTION TO AIR RELEASE VALVE AND A
4. FOR MONITOR WELL TUBES A & B - PROVIDE A SST FLANGE WITH WELLHEAD PRESSURE.PROVIDE A PRESSURE-TIGHT CABLE FITTING RATED FOR 20 PSI WITH THE INSTRUMENTATION AND CONTROL SYSTEM PACKAGE. SUBMERSIBLE WATER LEVEL TRANSDUCER LT~55 AS PROVIDED
3. FOR STORAGE ZONE MONITOR WELL TUBE C - INSTALL THE
PRESSURE OF 20 PSI. RECHARGE OPERATIONS AND SHALL BE CAPABLE OF A WELLHEAD WELLHEAD ASSEMBLY WILL BE UNDER PRESSURE DURING ASR MANUALLY MEASURING THE WATER LEVEL IN THE WELL. THE ALSO BE EASILY REMOVABLE TO FACILITATE A DROP TAPE FOR CONNECTION FOR AIR RELEASE VALVE ASSEMBLY WHICH SHALL CABLE OPENING FOR WATER LEVEL PROBE, D) 1/2 " NPT THREADED CABLE OPENING FOR PUMP POWER CABLE, C) PRESSURE SEALED AND THE 1" SAM-PVC DISCHARGE PIPING, B) PRESSURE SEALED CONNECTION BETWEEN BORELINE HOSE FROM THE SAMPLE PUMP SHOWN. TUBE C SHALL INCLUDE THE FOLLOWING: A) 1" SST PER THE DETAILS ON THIS DRAWING WITH HOLES AND TAPS AS MONITOR WELL.) PROVIDE A MATCHING 316 SST BLIND FLANGE AS SHALL BE THREADED, DO NOT USE SOLVENT WELDED PVC ON STAGGERED HEIGHT PATTERN AS SHOWN. (ALL CONNECTIONS INSTALL A 316 SST TOP FLANGE FOR EACH TUBE IN THE CASING TUBES AND TERMINATE ABOVE CONCRETE SLAB AND EXISTING GRADE WITH NPT THREADED ENDS. EXTEND THE PVC AND WERE EXTENDED APPROXIMATELY 6-INCHES ABOVE THE
2. THE MONITOR WELL CASING TUBES WERE INSTALLED BY OTHERS, REMOVAL. ALL FASTENERS SHALL BE TYPE 316 SST. .ANCHORS WITH SECURITY PATTERN TO INHIBIT TAMPERING AND ENCLOSURE TO THE CONCRETE SLAB USING 1#2" X 4" EXPANSION OPENING ENCLOSURE AS SHOWN ON DRAWING M18. MOUNT THE
1. A LOCKABLE, FABRICATED ALUMINUM, HINGED CLAM-SHELL
T
T
PUMP ROOM
CHEMICAL ROOM
ELECTRICAL ROOM
RESTROOM
B
19M02
16" PW
C
19M02
1 4
5 6
3 10
8 E
19M10
D
19M03
N 2047078.02
E 6736394.51
TO SANITARY
SEWER
FROM DISTRIBUTION
& 2" BACKFLOW
PREVENTER SEE
CIVIL YARD PIPING PLAN FROM 4" FDC
& BACKFLOW
PREVENTER
3" GRAVEL FILL TUBE
3 15
15 3
2" SOUNDING TUBE,
AND LEVEL
TRANSMITTER,
SEE DWG 19M10
WD34-PUMP-36101
N 2047061.14
E 6736373.46
12" AS
2 WD34-FCVX-36120
3 4" V
WD34-FCVX-36150
12" AR
20 4" TANK VENT SEE
CHEM ROOM
DWG 19M10
TYP
CY119
TYP
MP140
FROM/TO
DISTRIBUTION
CL 124.58
SEE DWG 19E11
14 9
D
16 SEE DWG 19M05
13 TO STORM DRAIN
AIR-GAP STRUCTURE
SEE CIVIL YARD PIPING
PLAN FOR OUTSIDE THE
BUILDING (TYPICAL)
WD34-MOVX-36160
1 19M03
2 19M03 23
NITROGEN GAS
CYLINDER TANK
DHCV VCP
(x2 FOR TWO
MONITORING WELLS
POWER AND 1" SAMPLE LINE
FROM THE MONITORING WELL
18 17
NITROGEN
2 TUBES
NITROGEN
2 HOSES
PRELUBE AND TRICKLE
FLOW. SEE SECTION
1/19M03
12" AS/AR
PRESSURE INDICATING
TRANSMITTER
24 10" AF
3/4" SH
TYP
12 MC777
11 3/4" NAF TYP
MC777
5' - 0"
ENCASEMENT (TYP)
(TYP)
2" PW
4" DR
4" FPW
BYPASS
WD34-MOVX-36140
12" X 10" RED
10" AS
WD34-MOVX-36130
12" AS/AR
20 20
3/4" PW
3' - 0"
ROSSUM SAND
TESTER
N 2047079.75
E 6736404.07
CL 124.58
CL 122.45
L
19M09
WD34-PITX-36109
26 1/4" NITROGEN VENT 1/2" SAM 22
GRINDER PUMP VCP
BUCK BOOST
TRANSFORMER
27 12" FE
10" AF
OPERATOR INTERFACE, SEE
KEYNOTE 1 ON SHEET 19GN01
21 28
25 TO FUTURE 12" FI FROM FUTURE 12" FE 3'-0" MIN 3'-0" MIN
TO STORM
DRAIN AIR-GAP
STRUCTURE
GENERAL NOTES:
1. SEE CIVIL FOR PIPING CONTINUATIONS
2. NOT ALL REQUIRED PIPE SUPPORTS ARE SHOWN.
3. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING OFFSET,
SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE THE PROCESS AND INSTRUMENTATION DIAGRAMS AND SPECIFICATION SECTION 15052- COMMON WORK RESULTS FOR GENERAL PIPING.
KEY NOTES:
1. ASR WELL PUMP
2. WELL ANNULUS RECHARGE VALVE
3. 2" AIR RELEASE VALVE (TYP)
4. RESTRAINED FLANGE COUPLING ADAPTER (TYP)
5. BI-DIRECTIONAL FLOW METER
6. 1" SPARE NIPPLE AND FULL-PORT BALL VALVE FROM
CENTERLINE SIDE OF PIPE
7. AQUIFER & WELL FLUSH TO WASTE VALVE.
8. PRESSURE REDUCING VALVE.
9. MODULATING RECHARGE CONTROL VALVE.
10. AQUIFER RECOVERY PRODUCTION VALVE.
11. FLUORIDE INJECTION SIM TO TYP DETAIL MC777/TYP.
12. SODIUM HYPOCHLORITE INJECTION SIM TO TYP DETAIL
MC777/TYP.
13. RESTRAINED FLEXIBLE COUPLING PER TYP DETAIL MP310/TYP.
14. 1/2" AIR RELEASE VALVE, SEE DETAIL 2/19M03.
15. INSTALL DIELECTRIC ISOLATION FLANGE AT INTERFACE
BETWEEN SST WELLHEAD AND DOWNHOLE WELL PIPING FROM
DISTRIBUTION PIPING.
16. INSTALL 1" SAMPLE TAP AND BALL VALVE, 1/2" TUBING,
POOL/HOUSE WATER FILTER CARTRIDGE WITH CLEAR CASING,
AND PREFORMED CHANNEL PIPE SUPPORTS AS REQUIRED FOR
VISUAL INSPECTION AND HAND TURBIDITY TESTING. WASTE TO
DRAIN. REFER TO P&ID DRAWINGS FOR LAYOUT AND VALVES.
17. FLUORIDE ANALYZER, SEE DETAIL 4/19M03
18. CHLORINE ANALYZER, SEE DETAIL 4/19M03
19. NOT USED.
20. ROUTE 1/2" CHEMICAL FLUORIDE AND CHLORINE TUBING FROM
THE CHEMICAL PUMPS IN THE CHEMICAL ROOM THROUGH THE
CHEMICAL TRENCH DRAIN TO THE INJECTION POINTS. ABOVE
GRADE TUBING WILL BE 3/4".
21. PUMP COLUMN RECHARGE CONTROL VALVE.
22. LOCATE BURIED SAMPLE TAP OUTSIDE OF CONCRETE
ENCASEMENT. INSTALL CORPORATION STOP. SEE SITE CIVIL
YARD PIPING PLAN.
23. NITROGEN PNEUMATIC HOSES TO DOWNHOLE CONTROL VALVE
(SEE WELLHEAD DETAIL)
24. AQUIFER FLUSH SWING CHECK VALVE
25. ROUTE 1" SAMPLE LINE FROM EXISTING MONITORING WELL TO INSIDE BUILDING. ROUTE SAMPLE LINE TO AVOID OTHER ABOVE
PEDESTAL OR WALL MOUNTED ENCLOSURES, AT-GRADE
HANDHOLES, AND PIPE SUPPORTS AS REQUIRED.
26. MOUNT CABLE TO MAXIMIZE ACCESS TO WELLHEAD.
COORDINATE LOCATION WITH OPERATION STAFF DURING
CONSTRUCTION.
27. INSTALL SHELF, COORDINATE LOCATION WITH OPERATIONS
STAFF.
28. SWING CHECK VALVE WITH WEIGHTED ARM.
#
REG I ST ERED PROFESS I ONA L ENG I NEER
ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 3:00:28 PM
R:\d1341485\11843A1019M800.rvt
19M01
MISTY WOODS ASR WELL
BUILDING PLAN 68
MECHANICAL
SMB
OB
MED
SCALE:
PLAN A 1/4" = 1'-0"
178
12"x10" RED
WELL ANNULUS
RECHARGE VALVE TYP
MP034 (TYP)
2" ARV
BI-DIRECTIONAL
MAG METER
MODULATING RECHARGE
CONTROL VALVE
10" PRESSURE
REDUCING VALVE
10" H-STRAINER
10"x8" RED
12"x8" RED
PUMP
12" AS/AR
12" AR
WD34-FCVX-36120
12" AS
WD34-FITX-36104
12" AS/AR
WD34-MOVX-36160
3/4" DRAIN LINE
W/ BALL VALVE (TYP)
FROM BOTTOM OF PIPE
PRESSURE TRANSMITTER
AND PRESSURE INDICATOR
PRESSURE TRANSMITTER AND
PRESSURE INDICATOR
WD34-FCVX-36150
WD34-PDIT-36151
WD34-PDIT-36151
10"X12" REDUCER
WD34-PIXX-36150
PRESSURE INDICATOR
PRESSURE DIFF W/ BYPASS
WD34-PIXX-36151
10" AS
CL 122.45
10" AF
CL 124.58
TO POOL FILTER
1" SPARE NIPPLE AND FULLPORT BALL VALVE FROM
CENTERLINE SIDE OF PIPE.
10" AS SCREEN
PUMP
12" SWING
CHECK VALVE
12" AS/AR NITROGEN
HOSE
PRESSURE TRANSMITTER
AND INDICATOR
2" ARV
2 19M03
WD34-PSHH-36107
PRESSURE SWITCH
HIGH
WD34-PITX-36102
WD34-PIXX-28102
TYP
MC777
TYP
MC777
3/4" NAF
3/4" SH
GENERAL NOTES:
1. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING OFFSET,
SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE THE PROCESS AND INSTRUMENTATION DIAGRAMS AND SPECIFICATION SECTION 15052- COMMON WORK RESULTS FOR GENERAL PIPING.
2. PROVIDE ISOLATION FLANGE KIT BETWEEN THE WELLHEAD AND ABOVE GROUND PIPING.
REG I ST ERED PROFESS I ONA L ENG I NEER
ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 3:00:30 PM
R:\d1341485\11843A1019M800.rvt
19M02
MISTY WOODS ASR WELL
BUILDING SECTIONS AND DETAILS 1 69
MECHANICAL
SMB
OB
MED
SCALE:
SECTION
3/8" = 1'-0" 19M01
B
SCALE:
SECTION
19M01 3/8" = 1'-0"
C
178
NITROGEN
TANK (TYP)
DHCV VCP
CHLORINE
ANALYZER
PANEL
FLUORIDE ANALYZER
PANEL
3 19M03
13 NITROGEN
TUBE
14 ROUTE 2 NITROGEN TUBES
TO FLOOR DRAIN TRENCH
THEN TO WELLHEAD
MONITORING WELL
PUMP CONTROLLER, MOUNT
ON WALL, SHELF, OR POST,
SEE TYPICAL DETAILS EM210
AND MP218
SPARE NITROGEN TANK
1/2" BACKFLOW PREVENTER
W/ WYE STRAINER
SAMPLE LINE FROM
12" AS/AR, SEE 19M01
TO BUILDING DRAIN LINE,
SEE PLUMBING PLAN
3" VENT
1/4" NITROGEN VENT
THROUGH WALL
1/2" SAM
1/2" SAM
VENT SEE PLUMBING PLAN
WD34-PITX-36122
PRESSURE ELEMENT
M
S
WELL CASING
WELL COLUMN PIPE
3/4" PRELUBE, THROUGH PUMP
DISCHARGE HEAD ASSEMBLY
PRELUBE SOLENOID VALVE
FLOW SWITCH
MAG FLOW
METER
GLOBE VALVE
(TYP)
THROTTLING
NITROGEN HOSES, SEE
WELLHEAD DETAIL
ANNULAR SPACE
WD34-FITX-36105
WD34-FSLX-36113
3/4" PW
PRESSURE
REDUCING
VALVE
3/4" TRICKLE
5 19M09
WATER LEVEL GAUGE
WD3-PIXX-36105
1/2" SEAL
INSTALL 1" THREADED NIPPLE, 1"
X 1/2" TEE AND 1" FULL PORT BALL
VALVE. INSTALL AIR AND VACUUM
RELEASE VALVE OFF OF 1/2" TEE.
1/2" AIR AND VACUUM
RELEASE VALVE,
1/2" BALL VALVE AND PIPING
LEVEL TRANSDUCER
CORD GRIP AND SEAL
WD34-LITX-36100
2" SOUNDING TUBE
NOTES:
1. VERIFY WITH CITY THAT THE
SOUNDING TAPE WILL PASS
THROUGH A 1" BALL VALVE
AND PIPE NIPPLE.
PLUG
2 1
10 3
4 12
GRAB
SAMPLE
2 9
3 5
16 TYP
8 7
6 8
4 9
16 TYP
10 5
7 3
10 2
GRAB
SAMPLE
11 KEY NOTES:
1. FLUORIDE ANALYZER, ROUTE SAMPLE DRAIN AND OVERFLOW
TUBES TO DRAIN FUNNEL WITH 2 DIAMETER AIR GAP
2. 1" PVC BACKER BOARD MOUNTED ON MASONRY WALL WITH
1/2" ANCHORS
3. BALL VALVE (TYP)
4. DIAPHRAGM VALVE
5. 0-40 GPM ROTAMETER
6. AIR RELEASE VALVE
7. PRESSURE GAUGE
8. PRESSURE REDUCING VALVE
9. 10" FILTER, 50 MICRON
10. NEEDLE VALVE
11. CHLORINE RESIDUAL ANALYZER, ROUTE SAMPLE DRAIN AND
OVERFLOW TUBES TO DRAIN FUNNEL WITH 2 DIAMETER AIR GAP
12. pH SENSOR
13. THREE "K" SIZE NITROGEN CYLINDERS, 1 DUTY + 2 SPARE, (228 SCF 9" DIA. x 51" TALL). SECURE TO WALL WITH PREFORMED CHANNEL
CHAIN, OR OTHER ACCEPTABLE MEANS
14. BASKI VENDOR CONTROL PANEL FOR DOWNHOLE FLOW CONTROL VALVE. ONLY A SCHEMATIC LAYOUT IS SHOWN. REFER TO
MANUFACTURER'S INSTALLATION MANUAL FOR LAYOUT, PIPE
SIZES, AND MATERIALS.
15. NOT USED.
16. INSTALL UNIONS OR VALVES WITH UNION CONNECTIONS AS
REQUIRED THROUGHOUT THE SAMPLE AND ANALYZER ASSEMBLIES
TO AID IN THE REMOVAL AND RE-ASSEMBLY OF VALVES AND
EQUIPMENT FOR MAINTENANCE.
GENERAL NOTES: #
1. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING OFFSET,
SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE THE PROCESS AND INSTRUMENTATION DIAGRAMS AND SPECIFICATION SECTION 15052- COMMON WORK RESULTS FOR GENERAL PIPING.
REG I ST ERED PROFESS I ONA L ENG I NEER
ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 3:00:31 PM
R:\d1341485\11843A1019M800.rvt
19M03
MISTY WOODS ASR WELL
BUILDING SECTIONS AND DETAILS 2 70
MECHANICAL
SMB
OB
MED
SCALE:
SECTION
19M01 3/8" = 1'-0"
D
SCALE:
DETAIL
19M01 NO SCALE
1 SCALE:
DETAIL
19M01 NO SCALE
2 SCALE:
DETAIL
1/2" = 1'-0" 19M03
3 178
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:08:32AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19M04
LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
MECHANICAL
11843A1019M004.dgn
PLUMBING SCHEDULES
WATER HEATER SCHEDULE
EQUIPMENT TAG AREA SERVED FLOW CAPACITY (GPM) TEMP. RISE (°F) ELEMENT (kW) MCA (Amps) VOLTAGE PHASE BASIS OF DESIGN NOTES WD05-HXGR-36002 RESTROOM .3 56 4.1 20 208 1 EEMAX EX4208T - WD37-HXGR-36401 CHEMICAL ROOM 23 21 72 87 480 3 HAWS 9327 1 NOTES:
1PROVIDE NEMA TYPE 4X CONTROL PANEL.
PLUMBING ROUGH IN SCHEDULE
TAG NO.PW (IN.)HW (IN.) D/SS (IN.) VENT (IN.) FIXTURE DESCRIPTION WC 1-1/4" N/A 4" 2" WATER CLOSET (ADA ACCESSIBLE)
LAV 1/2" 1/2" 1-1/4" 1-1/2" LAVATORY (ADA ACCESSIBLE)
HXGR 1-1/4" N/A N/A N/A TANKLESS WATER HEATER (HB&ESEW)HXGR 3/4" N/A N/A N/A TANKLESS WATER HEATER (SINK)
WATER HAMMER ARRESTOR SCHEDULE
SMITH MODEL * PDI SYMBOL ** FIXTURE UNIT RATING
5005 A 1-11
5010 B 12-325020 C 33-605030 D 61-1135040 E 114-1545050 F 155-330 * SMITH OR EQUAL ** PLUMBING DRAINAGE INSTITUTE "STANDARD PDI WH-201"
MISTY WOODS ASR WELL
kbequette
71 CG
G
19M10
4" MUD VALVE
IN SUMP INV EL128.03
4" FCO
INV 128.93 4" DR
REFER TO STRUCTURAL
FOR TRENCH DESIGN
(TYP)
4" FD
(IN TRENCH)
INV 128.90
2" HD
(FOR ANALYZERS)
4" DR
4" FD
3" V
3" VTR
3" VTR
3/4" HOSE
VALVE
3/4" HOSE VALVE
1 1/2" PW
FROM 2" BACKFLOW
PREVENTER. REFER TO CIVIL
FOR CONTINUATION
WD05-HXGR-36002
MAG METER
2" PW
PRESSURE REDUCING VALVE.
INSTALL WYE STRAINER
UPSTREAM OF VALVE
3/4" PW
1 1/2" PW
3/4" PW
TYP
HP640 (TYP)
2 1
TYP
(TYP) HP538
TYP
HP318 (TYP)
TYP
MA417
CL 100.20
CL 145.25
1/2" PW
(BELOW)
1 1/2" PW
CL 145.25
4" FD
3/4" FREEZELESS
WALL HYDRANT
TYP
MA417
SK
2" DR
REFER TO CIVIL
FOR CONTINUATION
REFER TO STRUCTURAL
FOR TRENCH DESIGN
(TYP)
4" DR
3/4" PW
CL 100.20
LAV
SLOPE
TO DRAIN
BELOW
CHEMICAL DRAIN
TRENCH
DRAIN TO SUMP
SLOPE
TO DRAIN
INV 126.30 INV 126.16
CHEMICAL SUMP
REFER TO CIVIL
FOR CONTINUATION
TERMINATE 4" FPW LINE 2'-0"
ABOVE GRADE. PROVIDE END CAP
AT END OF PIPE FOR FUTURE USE
3" DR
4" FPW
TRICKLE FLOW WITH
ISOLATION VALVE AND
LEVEL GAUGE, SEE
DETAIL 5/19M09
PRELUBE WITH ISOLATION
BALL VALVE, FLOW SWITCH
AND SOLENOID VALVE, SEE
ELECTRICAL
SLOPE
TO SUMP
RIM 131.28
2" DR INV 129.55
INV 130.25
2" DR
WC
3 TYP
INV 128.61
SLOPE TO DRAIN
GRADE BREAK
WD34-LEXX-36XX 4
TYP
MP018
INV 129.14
4" FD
3" V
3" V
TYP
CY411
MP003
(TYP)
3" V
SS VENT
2" SFM
SSMH WITH
GRINDER PUMP
STATION
GENERAL NOTES:
1. PIPING SHALL BE FIELD ROUTED TO AVOID EQUIPMENT, PROCESS PIPING, AND OTHER ITEMS AS NECESSARY.
2. SLOPE ALL DRAIN LINES 2-1/2’’ AND BELOW AT A MINIMUM OF 1/4’’ PER FOOT IN THE DIRECTION OF FLOW.
3. SLOPE ALL DRAIN LINES 3’’ AND ABOVE AT A MINIMUM OF 1/8’’ PER FOOT IN THE DIRECTION OF FLOW.
4. ALL PIPING SHALL BE CONSTRUCTED FROM MATERIALS DEFINED IN SPECIFICATION 15052.
5. ALL DRAINS CONNECTED TO THE SANITARY SEWER SYSTEM TO CONTAIN P-TRAPS PER DETAILS HP220/TYP AND MA201/TYP.
6. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING
OFFSET, SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR
DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE
THE PROCESS AND INSTRUMENTATION DIAGRAMS AND
SPECIFICATION SECTION 15052-COMMON WORK RESULTS FOR
GENERAL PIPING.
7. REFER TO STRUCTURAL AND MECHANICAL FOR TRENCH DETAILS, SLOPING, AND PIPING. TRENCHES SHOWN ON THIS SHEET FRO
REFERENCE ONLY.
KEY NOTES:
1. SURFACE MOUNTED MECHANICAL TRAP PRIMER. PRIMER TO SERVE ALL DRAINS WITH P-TRAPS.
2. MAINTAIN 32’’ CLEARANCE AROUND EMERGENCY SHOWERHEAD.
3. MINIMUM 1.5% SLOPE BACK TO CHEMICAL SUMP WITHIN DEEPENED SLAB SECTION. REFER TO STRUCTURAL NOTES FOR MINIMUM
CLEARANCE AND OTHER REQUIREMENTS.
4. LEVEL SWITCH IN CHEMICAL SUMP.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 9:23:50 AM
R:\d1341489\11843A10019P800.rvt
19M05
MISTY WOODS ASR WELL
PLUMBING PLAN 72
MECHANICAL
CAG
KHB
WJS
SCALE:
PLAN A 1/4" = 1'-0"
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:07:51AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
CAG
11843A1019M006.dgn
MECHANICAL 19M06
HVAC SCHEDULES 73
FAN SCHEDULE
EQUIPMENT TAG AREA SERVED FAN TYPE
AIR FLOW
(CFM)
ESP
(IN. W.C.)
FAN
RPM
NOISE
(SONES)
MOTOR DRIVE
TYPE
BASIS OF DESIGN NOTES
HP RPM V/PH/HZ ENCLOSURE
WD05-FANx-36303 RESTROOM TYPE 5 140 0.7 1050 4.5 0.128 (kW) 1050 115/60/1 ODP DIRECT GREENHECK SP-B150 5 WD37-FANx-36301 PUMP ROOM TYPE 4 700 0.35 1160 12.2 1/4 1160 460/60/3 TEFC DIRECT GREENHECK AER-E20C-603-B3 WD37-FANx-36302 CHEMICAL ROOM TYPE 4 700 0.35 1160 12.2 1/4 1160 460/60/3 TEFC DIRECT GREENHECK AER-E20C-603-B3 1, 2, 3, 6, 7 NOTES:
1PROVIDE BIRD SCREEN.
2PROVIDE BACKDRAFT DAMPER BDD-3, COUNTERBALANCED FOR MINIMUM PRESSURE LOSS. 3PROVIDE DISCONNECT SWITCH AT FAN, NEMA TYPE 4X.
4PROVIDE THERMOSTAT AS SPECIFIED IN SECTION 15936.
5FAN SHALL BE INTERLOCKED WITH LIGHT SWITCH.
6PROVIDE HI-PRO POLYESTER COATING.7PROVIDE ACOUSTICAL LOUVER L-3 AS SPECIFIED IN SECTION 08910.
MISTY WOODS ASR WELL
kbequette
WD37-HVAC-36105 ELECTRICAL ROOM - 90/67 48/34 55 54
NOTES:
1 2
3 4
THERMOSTAT PROVIDED BY MANUFACTURER.CONTROL SYSTEM SPECIFIED IN SECTION 15936- INSTRUMENTATION AND CONTROL DEVICES FOR HVAC.PROVIDE INTERNAL CONDENSATE LIFT PUMP ACCESSORY.PROVIDE CONDENSING UNIT SIZED PER VRF MANUFACTURER TO PROVIDE HEATING AND COOLING REQUIREMENTS AS INDICATED FOR ASSOCIATED FAN COIL UNITS 1,218 105 PER MFR PER MFR MERV 13 1 208 1 1.8 DAIKIN FXFQ48TVJU 1, 2, 3, 4 WD37-HVAC-36104 ELECTRICAL ROOM 1,165 - 105 90/67 PER MFR 36/28 55 PER MFR 40 MERV 13 1 208 1 1.5 DAIKIN FXFQ36TVJU 1, 2, 3, 4 WD37-HVAC-36103 ELECTRICAL ROOM
1,165 - 105 90/67 PER MFR 48/34 55 PER MFR 54 MERV 13 1 208 1 1.8 DAIKIN FXFQ48TVJU 1, 2, 3, 4 WD37-HVAC-36101 ELECTRICAL ROOM - - 105 - - - - - - 460 3 55.1 4
AIR CONDITIONING / HEAT PUMP SCHEDULE
EQUIPMENT TAG AREA SERVED
AIRFLOW
(CFM)
ESP
(IN. W.C.)
COOLING DATA FILTER DATA ELECTRICAL DATA
OA DB/WB BASIS OF DESIGN NOTES
(°F)
EAT DB/WB
(°F)
LAT DB/WB
(°F)
TOTAL / SENSIBLE CAPACITY
(MBH)
EFFICIENCY
THICKNESS
(IN.)
VOLTAGE PHASE
MCA
(AMPS)
MECHANICAL HEATING DATA
EAT DB/WB
(°F)
LAT DB/WB
(°F) (MBH)
TOTAL CAPACITY
WD37-HVAC-36102 ELECTRICAL ROOM
1,218 - 105 90/67 PER MFR 36/28
160
55 PER MFR
130
40 MERV 13 1 208 1 1.5 DAIKIN FXFQ36TVJU
DAIKIN RXYQ198XATJA
1, 2, 3, 4
ELECTRIC UNIT HEATER SCHEDULE
EQUIPMENT TAG AREA SERVED
HEATING CAPACITY
(kW)
AIRFLOW
(CFM)
MCA
(Amps)
VOLTAGE PHASE BASIS OF DESIGN NOTES
WD37-HEAT-36201 PUMP ROOM 3 700 5 480 3 TRIAD 234-U11N-0030U 1, 2, 3, 4 WD37-HEAT-36202 PUMP ROOM 3 700 5 480 3 TRIAD 234-U11N-0030U 1, 2, 3, 4 WD37-HEAT-36203 CHEMICAL ROOM 5 700 8 480 3 TRIAD 234-U11N-0050U 1, 2, 3, 4 WD37-HEAT-36204 ELECTRICAL ROOM 3 700 5 480 3 TRIAD 234-U11N-0030U 1, 2, 3, 4 NOTES:
1THERMOSTAT PROVIDED BY HEATER MANUFACTURER. THERMOSTAT SHALL BE LOCKED OUT AND NOT ALLOW HEATING ABOVE 55 DEGREES FAHRENHEIT. 2WALL MOUNTED.
3SIDE AIR DISCHARGE.
1, 2, 3, 4, 6, 7
T
T
700
CFM EA
11 TO
WD37-FANX-36301
WD37-HEAT-36202
WD37-HEAT-36203
8 12
WD37-HEAT-36201
700
CFM OA 6 2
6"ø EA
WD05-FANX-36303
100
CFM EA
WD37-HEAT-36204
TO VRF SYSTEM
WD37-FANX-36301
TYP
HE350 (TYP)
TYP
HE520 (TYP)
TYP
HE620 (TYP)
13 13
13 700
CFM EA
WD37-FANX-36302
13 700
CFM OA
9 WD37-HVAC-36102
(TYP)7
WD37-HVAC-36104 WD37-HVAC-36105
10 TYP
HE166 (TYP)
(TYP)3
WD37-HVAC-36101 5
4 1
WD37-HVAC-36103
TYP
HE620 (TYP)
CHEMICAL ROOM
PUMP ROOM
GENERAL NOTES:
1. MOUNT THERMOSTATS AT 48” AFF AND LABEL WITH ITS
CONTROLLING DEVICE. THERMOSTAT LOCKBOXES TO BE
PROVIDED BY MECHANICAL CONTRACTOR.
2. DUCTWORK SERVING ELECTRICAL ROOM TO BE ALUMINUM PER
SECTION 16133. DO NOT ROUTE ABOVE ELECTRICAL EQUIPMENT.
3. ALL DUCTWORK AND SUPPORTS SHALL BE CONSTRUCTED PER
SMACNA. REFER TO SPECIFICATION SECTION 16133 FOR
ADDITIONAL REQUIREMENTS.
4. DRAWINGS ARE DIAGRAMMATICAL AND NOT EVERY PIPING
OFFSET, SIZE, MATERIAL, FITTING, VALVE, INSTRUMENT, OR
DIELECTRIC IS SHOWN, PROVIDE AS REQUIRED. PROVIDE MINOR MODIFICATIONS TO PIPING AND SUPPORTS AS REQUIRED. SEE
THE PROCESS AND INSTRUMENTATION DIAGRAMS AND
SPECIFICATION SECTION 15052-COMMON WORK RESULTS FOR
GENERAL PIPING.
KEY NOTES:
1. 32’’x24’’ INTAKE LOUVER TYPE L-3 TO BE MOUNTED AT 8’-0’’ AFF.
2. BACKDRAFT DAMPER (BDD-3).
3. MANUFACTURER REQUIRED CLEARANCE. DO NOT BLOCK.
4. REFRIGERANT LINES. LINES WILL ENTER THE PUMP ROOM DOWN LOW THEN RISE TO BE ROUTED UNDER THE HARD CEILING. FIELD ROUTE TO FAN COIL UNITS IN ELECTRICAL ROOM. AVOID RUNNING LIQUID SIDE PIPE OVER ELECTRICAL EQUIPMENT. INSULATE ALL PIPING PER SPECIFICATIONS.
5. HEAT PUMP TYPE CONDENSING UNIT SERVING VRF. CONTRACTOR TO SUBMIT ANCHORAGE CALCULATIONS PER SPECIFICATION 01850.
6. 16''x8'' EXHAUST BRICK VENT TO BE MOUNTED AT 9’-4’’ AFF.
7. INDOOR VRF FAN COIL UNIT TO BE MOUNTED UNDER CEILING PER MANUFACTURER STANDARDS. SUBMIT SHOP DRAWINGS AND
CALCULATIONS FOR INDOOR UNIT SUPPORTS PER SPECIFICATION 01850. CONTRACTOR TO COORDINATE WITH TRUSS MANUFACTURER FOR ADDITIONAL LOADING. DO NOT PLACE ABOVE ELECTRICAL
EQUIPMENT.
8. WALL MOUNTED EXHAUST FAN AND CORRESPONDING ACOUSTICAL LOUVER TYPE L-3 TO BE MOUNTED IN WALL AT 2'-0" AFF PROVIDE FAN WITH GUARD.
9. ROUTE CONDENSATE PIPING OUT OF BUILDING AND INTO DRY WELL. SLOPE CONDENSATE DRAIN AT 1/8'' PER FOOT IN THE
DIRECTION OF FLOW.
10. 1'' SCH 40 PVC CONDENSATE DRAIN PIPE. INSULATE PER
SPECIFICATIONS.
11. WALL MOUNTED EXHAUST FAN AND CORRESPONDING ACOUSTICAL LOUVER TYPE L-3 TO BE MOUNTED IN WALL AT 7'-4" AFF PROVIDE FAN WITH GUARD.
12. 32"x24" INTAKE LOUVER TYPE L-3 TO BE MOUNTED AT 2'-0" AFF.
13. WALL MOUNTED ELECTRIC UNIT HEATER. MOUNT HEATER AT
8’-0’’ AFF.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 9:29:30 AM
R:\d1341488\11843A1019H800.rvt
19M07
MISTY WOODS ASR WELL
HVAC PLAN 74
MECHANICAL
CAG
KHB
WJS
SCALE:
PLAN K 1/4" = 1'-0"
(TYP)
THERMOSTAT
TYPE L-3 (TYP)ACOUSTICAL LOUVER
T
No. 37915
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20246:08:26AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
WJS
KHB
11843A1019M008.dgn
CFM EA
100
CFM EA
700
RESTROOM
WD05-FANx-36303 WD37-FANx-36301
T
CFM SA
1,165
T
CFM OA
700
CFM EA
700
CFM OA
700
WD37-HVAC-36101
WD37-HEAT-36204
T
T
WD37-HEAT-36203
WD05-FANx-36302
WD37-HEAT-36202 WD37-HEAT-36201
T
PUMP ROOM
CHEMICAL ROOM
19M08
HVAC AIRFLOW SCHEMATIC
CFM SA
1,218
CFM SA
1,218
CFM SA
1,165
WD37-HVAC-36102 WD37-HVAC-36103 WD37-HVAC-36104 WD37-HVAC-36105
MECHANICAL
MISTY WOODS ASR WELL
kbequette
ROOM
ELECTRICAL
75 CFM INFILTRATION
100
CG
6 '-21/2"
3'-2"
2'-8"
2'-2" 1'-9"
1"
6"
2"
6"
3"
4 1/2"
4"
1'-0"
1'-4"
2'-2" 6"
1'-0"
6"
6"MIN
6"MIN
BELOW GRADE (TYP)MIN 3" EDGE DISTANCE
MAX 40.24"
2'-0"
1'-0"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-202411:48:12AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19M09
LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
TLR
MECHANICAL
WELLHEAD DETAILS
11843A1019M009.dgn
GENERAL NOTES:
3/8"
3/8"
SST WELLHEAD
FABRICATED 316L
DISCHARGE HEAD
FABRICATED 304 SST PUMP
SST WELLHEAD
FABRICATED 304
3/8"
ASR WELL PUMP
3/4" SST NIPPLE3/4" TF-POLY
SST
POLY
3/4" SST NIPPLE
1/4" V307
MODEL IPG45-WLSS)
(AMERICAN GRANBY
WATER LEVEL GAUGE
5 6" = 1'-0"
11843A1009M400
TRICKLE FLOW CONNECTION
13'-4"
WELL PUMP MOTOR
12" AR
CL +3.50
CL +2.50
WELD REPLACEMENT WELLHEADCUT EX-CASING AND FIELD
WELLHEAD
EXISTING
WELLHEAD
CL +1.25
10" AS
T.O.W. +14.00
EX FIN GR
ELEV 0.00TOC DATUM
SEE STRUCTURALBUILDING FOUNDATION,
L
19M01
11843A1009M400
1" = 1'-0"
22.25°
22.25°
EX FIN GR
VALVE W/ SST CAP
SST SCHRADER
76 EL +11.86
ANNULAR RECHARGE)
(AQUIFER STORAGE,
SEE CIVIL/STRUCTURALBUILDING ELEVATION,
SECTION 11313 VERTICAL TURBINE PUMPS12" PUMP COLUMN, SEE SPECIFICATION CONCRETE BUILDING SLAB AND WELLHEADCONDUCTOR CASING ENOUGH TO INSTALL EXCAVATE AND EXPOSE EXISTING#5 @ 8" O.C. 1/2" BJF
PUMP DISCHARGE)(AQUIFER RECOVERY,
ALL OTHER ARE SHOP WELDSFIELD WELD TO EXISTING CASING,
EX-304 SST CASING
SST WELDOLET1 1/2" NPT 304
10" 304 SST
SECTION 05120 STRUCTURAL STEELFABRICATED WELLHEAD IN SPECIFICATION INSPECTION REQUIREMENTS FOR SEE FABRICATION, WELDING, AND 5 AND TUBE EXTENSIONS (TYP)WELD 22.25 DEG BENDS CUT EX-TUBES AND FIELD 3/4" TF-SST
3/4" BALL VALVE
1/4 SST PLUG
3/4" SST TEE
EXISTING CONDUCTOR CASING, WHICH EVER IS LARGER.ENCASEMENT, 42" DIAMETER OR MATCH CYLINDRICAL CONCRETE WELLHEAD HOOPS @ 12" O.C.#4 ROUND
MECHANICAL DWGSFOR ARV, SEE SST WELDOLET1-1/2" NPT 304
M
1" = 1'-0"
11843A1009M400
WELLHEAD - N 1" = 1'-0" 11843A1009M400 -WELLHEAD (TYP A & B) P 1" = 1'-0" 11843A1009M400 -WELLHEAD (TYP A & B)
EXISTING CASING
INSTALLATION INSTRUCTIONSMANUFACTURER'S PRELUBE, REFER TO PUMP 12" COLUMN PIPEHEAD W/ 18" FLANGE AND12" WELL PUMP DISCHARGE SST FLANGE10" AS 304
PUMP HEAD & WELLHEAD
PUMPHEAD
TRICKLE FLOW CONNECTION
3" MIN COVER
COUPLINGS, TYPICALSST NIPPLES AND
LENGTH OF TUBINGRECOMMENDATIONS, TYPICAL FOR THESPACERS PER MANUFACTURER'SSST BAND CLAMPS AND PROTECTIVESTRAP TUBING TO COLUMN PIPE USING 10" X 12" REDUCER, WELDED10" PUMP COLUMN
FLANGE O.D. 15" MAX.UNDERSIDE OF WELLHEAD,10" PIPE FLANGE BOLTED TO
WELLHEAD
WELLHEAD
FIELDVERIFYFIELDVERIFY
PUMPHEAD
18" CASING
FITTING FLANGE
18" SST WELL HEAD
FLANGE
18" PUMP HEAD
MAX O.D. 15"
10" PIPE FLANGE,
2 19M03
NOTE:
FABRICATIONPRIOR TO PROCUREMENT ANDLOCATIONS, AND ORIENTATIONWALL THICKNESS, MATERIALS,FIELD VERIFY ALL PIPE DIAMETERS, 19M09
19M0319M09
TYP
CP175
FLANGE KIT DETAILISOLATION JOINT
MISTY WOOD ASR WELL
eparker
RM
SHALL BE PICKLED AND PASSIVATED.MINIMUM. ALL STAINLESS STEEL WELDS WELDING SHOULD BE KEPT TO A CONTROLLED CONDITIONS. FIELD IN THE SHOP UNDER IDEAL AND PERFORM AS MANY WELDS AS POSSIBLE AND WELDS SHOULD BE INSPECTED. QUALIFIED WELDERS SHOULD BE USED, ARE STRUCTURAL COMPONENTS. NOTE: THE WELL HEAD AND PUMP HEAD A-778 TYPE 304 SST CASING20" I.D. X 3/8" WALL ASTM
NITRONIX TAPERED
20" I.D. X 3/8" WALL ASTM A-778 TYPE 304 SST CASINGA-778 TYPE 304 SST CASINGEX - 20" I.D. X 3/8" WALL ASTMA-139 GRADE B STEEL CONDUCTOR CASINGEX - 36" O.D. X 3/8" WALL ASTM COLUMN PIPE ARE PLUMB.WELLHEAD, LINESHAFT ANDLEVEL EDGE SO THAT THECASING WITH A STRAIGHTSHALL CUT EXISTING WELLNOTE: CONTRACTOR SST CASING, FIELD VERIFYASTM A-778 TYPE 30420" I.D. X 3/8" WALLMATCH EXISTING DRAWINGS.ACCORDANCE WITH THE REQUIREMENTS DESCRIBED ON THE THE CONCRETE. THE CONCRETE AND REINFORCING SHALL BE IN PROVIDE 0.5-INCH MINIMUM CHAMFER ALL EXPOSED EDGES OF CASING AND SUPPORTED BY THE GROUT AROUND THE CASING. SHOWN, SHALL BE FULLY SEATED TO THE TOP OF THE SURFACE ENCASEMENT. AROUND THE FINISHED WELLHEAD ASSEMBLY AS
7. THE CONTRACTOR SHALL PROVIDE THE REINFORCED CONCRETE FOR POTABLE WATER USE.THE SCHRADER VALVE. ALL MATERIALS SHALL BE NSF APPROVED AS A BUBBLER TYPE INDICATOR WHEN AIR IS CHARGED THROUGH DROPPED THROUGH THE TOP OF THE TEE ON THE PUMP BASE. OR MEASURING WATER LEVEL VIA A MANUAL TAPE THAT CAN BE THE WELL, AND SHALL SERVE AS A BACKUP MEANS OF CHLORINATED WATER VIA TRICKLE FLOW (TF) CONNECTION INTO THE TUBING SHALL SERVE A DUAL PURPOSE OF DIRECTING FT SPACING TO A DEPTH OF 1 FOOT ABOVE THE BOWL ASSEMBLY. STRAPPED TO THE PUMP COLUMN WITH SST HOSE CLAMPS AT 10
6. PROVIDE 0.75-INCH DIAMETER SEMI-RIGID POLYETHYLENE TUBING SPECIFIED ON THESE DRAWINGS. CONNECTIONS AND APPURTENANCES AS SHOWN AND AS MANUFACTURER'S RECOMMENDATIONS. PROVIDE ALL SPECIAL
5. INSTALL THE VERTICAL TURBINE PUMP AS PER THE
ABOVE THE PLUG.PROCESS. PROMPTLY REMOVE ANY MATERIALS THAT FALL IN FOR ENTRY OF FOREIGN MATERIALS DURING THE CONSTRUCTION TO ATMOSPHERE. THE CONTRACTOR SHALL BE RESPONSIBLE A TEMPORARY INFLATABLE PLUG NEAR THE SURFACE WHEN OPEN MATERIALS AT ALL TIMES DURING CONSTRUCTION BY THE USE OF
4. THE WELL SHALL BE PROTECTED FROM THE ENTRY OF FOREIGN COMPONENTS. UNSATISFACTORY WELDS OR DAMAGED MATERIALS AND RESPONSIBLE TO REMOVE, REPAIR, AND REPLACE ANY WORK AND TECHNICAL SPECIFICATIONS. THE CONTRACTOR IS PROCEDURES AND INSPECTIONS PER THE CONTRACT SCOPE OF WELDER AND IS SUBJECT TO FIELD WELDING AND SHOP WELDING STRUCTURAL STEEL, SHALL BE PERFORMED BY A CERTIFIED FABRICATED WELLHEAD SHALL BE CONSIDERED TO BE
3. THE FIELD WELDING TO THE EXISTING WELLHEAD AND THE NEW COVER OVER BAR AND CHAMFER EDGE. ENCASEMENT AROUND NEW WELLHEAD. PROVIDE MINIMUM AND GRAVEL FILL PIPES. INSTALL REINFORCED CONCRETE PIPE THICKNESS, AND MATERIAL TO EXISTING SOUNDING TUBE FITTINGS, BOLTS, VALVES, AND LEVEL INSTRUMENT. MATCH NEW FLANGE AS TO ENABLE THE EASY REMOVAL OF THE FLANGED CENTER OF THE WELL HEAD AND OUT FROM UNDER THE CASING WELD ON NEW FABRICATED TUBES TO BEND OUTWARD FROM THE EXISTING SOUNDING TUBE AND GRAVEL FILL PIPES AND FIELD THICKNESS, AND MATERIAL TO EXISTING SST CASING. CUT PIPING ORIENTATION REQUIREMENTS. MATCH NEW SST SIZE, HOLES SHALL BE COORDINATED WITH THE PUMP MOUNTING AND DIMENSIONS AND PLACEMENT OF THE TOP FLANGE AND THE BOLT WELLHEAD SHALL BE WELDED PLUMB AND TRUE. THE SIZE ELEVATION WITH A CLEAN LEVEL/PLUMB EDGE. THE FABRICATED BUILDING SLAB AND WELLHEAD. CUT EXISTING SST CASING TO AND CONCRETE ENCASEMENT ENOUGH TO INSTALL CONCRETE GRADE. EXPOSE AND DEMOLISH EXISTING CONDUCTOR CASING SEAL AND ENCASEMENT EXTEND TO APPROXIMATELY EXISTING EXISTING CARBON STEEL CONDUCTOR CASING AND CONCRETE AND GRAVEL FILL TUBE EXTENDS ABOVE EXISTING GRADE. THE
2. THE EXISTING STAINLESS STEEL WELL CASING, SOUNDING TUBE, JANUARY 2024AS-BUILTS, BY LUHDORFF & SCALMANINI CONSULTING ENGINEERS, EXISTING WELL CONSTRUCTION SEE "MISTY WOOD WELL
1. THE EXISTING WELL WAS CONSTRUCTED BY OTHERS. FOR
M- FLANGE O.D. 15"
FROM COLUMN PIPE TO PUMP HEAD,10" FLANGE ON 10" X 12" REDUCER A-778 TYPE 304 SST CASINGEX-20" I.D. 3/8" WALL ASTM
ASTM A-139 GRADE B STEELEX-36" O.D. X 3/8" WALLENCASEMENTCONCRETE WELLHEAD 12" COLUMN PIPE
12" AR
PUMP DISCHARGE)
(AQUIFER RECOVERY
19M09 THE EXISTING WELL
TOP VIEW OF 11
CONTROL VALVE)(FOR BASKI DOWNHOLEBOTTOM TO MEET COUPLINGB.C. 3/8" NPT THREADS FROM[2] 3/8" COUPLINGS ON 8.81" O.D. AND 18" CASING I.D., TYPICALBETWEEN 10" PIPE FLANGEPENETRATION EQUALLYSEE DETAIL 5/-. CENTERWATER LEVEL GAUGE,TRICKLE FLOW AND
LOCATION BY PUMP SUPPLIERMECHANICAL SEAL WATER,
LOCATION BY PUMP SUPPLIERSHAFT PRELUBE WATER,
LEVEL PRESSURE TRANSDUCERSOUNDING TUBE W/WATEREX-2" SCH 40 304 SST
PUMP DISCHARGE, TYPICALTUBE IS NOT UNDEROUTWARD SO THATEXTEND TUBE AND BEND GRAVEL FILL PIPEEX-3" SCH 40 BSP
N- P- 22° 0°
135°
180°
270°
321°
315°
11- NOT TO SCALE
EXISTING WELL - TOP VIEW EXISTING WELL - NORTH ELEVATION GRAVEL FILL PIPEEX-3" SCH 40 BSP
SOUNDING TUBE EX-2" SCH 40 304 SST
ANNULAR RECHARGE)
(AQUIFER STORAGE,
10" AS
1/2" SEAL
(2) 1/4" NITROGEN
3/4" PRELUBE
I.D., TYPICAL SEE DETAIL 5.10" PIPE FLANGE O.D. AND 20" CASINGBETWEEN TRICKLE FLOW CONNECTIONCENTER PENETRATION EQUALLY
GRAVEL FILL PIPE
3" SCH 40 BSP
SOUNDING TUBE
2" SCH 40 304 SST
304 SST
WALL ASTM A-778 TYPE
WELL CASING 12" X 3/8"
POLY CONNECTOR
3/4" SST TO 3/4"
ASTM A-139 GRADE B STEEL
36" O.D. X 3/8" WALL
CONDUCTOR CASING
GRADE
ABOVE EXISTING
POSSIBLE 18"
AVOID WELD IF
BALL SWING CHECK.
INTO DISTRIBUTION, THREADED SST 3/4"
CHECK VALVE TO PREVENT BACKFLOW
3/4" TRICKLE
11843A1019M601/602
M
REG I ST ERED PROFESS I ONA L ENG I NEER ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
F
19M10
1 2
14 3
4" V
11 CHEMICAL ROOM
5 9
G
19M10
10 4
13 12
15 3/4" SW
16 TANK FILL
3/4" NAF 3/4" V
H
19M10
6 18
3" OF
17 2" SH
GRINDER PUMP VCP
PER SPECIFICATION 11309 BUCK BOOST
TRANSFORMER
19 CHEMICAL ROOM
16"x12" RED
4" V
CL 142.00
3 6
13 16" PW
5 8
3/4" SW
3/4" NAF
3/4" V
20 10
TANK FILL
PRV
3" OF
2" SH
11 16 16
1 17
9 6
7 20
GENERAL NOTES:
1. SEE CIVIL FOR PIPING CONTINUATIONS
2. NOT ALL REQUIRED PIPE SUPPORTS ARE SHOWN.
3. ALL PIPE SUPPORTS WITHIN THE CHEMICAL ROOM SHALL BE FRP, UNLESS OTHERWISE NOTED. WALL PIPE SUPPORTS PER MP218/TYP, FLOOR PIPE SUPPORTS PER MP034/TYP, AND VERTICAL PIPE
SUPPORTS PER MP042/TYP.
4. ALL PIPE SUPPORTS USED FOR CHEMICAL SERVICE TO USE
CUSHION STRIPS BY ANVIL #AS 3792 OR EQUAL.
5. ALL BALL VALVES USED FOR SODIUM HYPOCHLORITE SERVICE SHALL BE VENTED BALL TYPE.
KEY NOTES:
1. 1,000 GALLON DOUBLE CONTAINED SODIUM HYPOCHLORITE
TANK PER SPEC 13208
2. EMERGENCY SHOWER & EYEWASH STATION PER HP640/TYP SEE PLUMBING PLAN, DWG 19M05.
3. TANK VENT ROUTED THROUGH WALL PER P302/TYP, TERMINATE AT A 45 DEGREE ANGLE WITH BIRD SCREEN
4. LEVEL INSTRUMENT
5. SODIUM HYPOCHLORITE DUAL PUMP SKID PER SPEC 11242
6. 2" VENTED BALL VALVE
7. 2" BALL CHECK VALVE
8. BACKFLOW PREVENTER, DIRECT DRAIN TO FLOOR DRAIN BELOW
9. TANK FILL 2" QUICK DISCONNECT HOSE COUPLING WITH CAP ANGLED DOWNWARD 22 DEGREES, VENTED BALL VALVE, AND
BALL CHECK VALVE SUPPORTED FROM FLOOR
10. 3" OVERFLOW, ROUTE PIPING TO SUMP
11. FLEXIBLE FITTING PER TANK MANUFACTURER
12. WATER SOFTENER PER KINETICO, MODEL S650XP AND BRINE TANK MODEL 7202
13. PACKAGED FLUORIDE DOSING SKID PER SPEC 11249
14. INSTANT WATER HEATER. SEE PLUMBING PLAN, DWG 19M05.
15. UTILITY SINK
16. ZURN 6" WIDE TRENCH DRAIN #ZF806-HDS-BDE WITH STAINLESS STEEL TOP FRAME AND GRATING COVER. TRANSITION FROM
PVC PIPE TO PFA TUBING IN TRENCH
17. REVERSE LEVEL FLOAT GAUGE
18. FRP GRATING COVER FOR SUMP, TRAFFIC RATED.
19. TANK DRAIN TO BE LOCATED AT THE BOTTOM OF THE TANK TO ALLOW FULL DRAINAGE. CUT NOTCH OUT OF CONCRETE PAD
AND ADJUST REBAR TO AVOID CONFLICTS.
20. PRIOR TO INSTALLING CONCRETE TANK PAD, VERIFY WITH PUMP
CHEMICAL PUMP MANUFACTURER AND SUPPLIER THAT MINIMUM
LIQUID LEVEL OF TANK MEETS MINIMUM NET POSITIVE SUCTION HEAD REQUIRED FOR CHEMICAL FEED PUMPS. RAISE TANK PAD
IF REQUIRED.
#
3/4" SW
12 TYP
P302
2 14
15 1/2" PW
3" V
1" PW
2" PW
1 1/2" PW
1/2" NAF 1/2" SH
16 1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 3:00:36 PM
R:\d1341485\11843A1019M800.rvt
19M10
MISTY WOODS ASR WELL
CHEMICAL ROOM 77
MECHANICAL
SKG
OB
RM
SCALE:
ENLARGED PLAN
3/8" = 1'-0" 19M01
E
SCALE:
SECTION
1/4" = 1'-0" 19M10
F
SCALE:
SECTION
1/4" = 1'-0" 19M10
G
SCALE:
SECTION
1" = 10'-0" 19M10
H
SLOPE VENT PIPES TO
DRAIN TO TANK, 1/4" PER
FOOT, TYPICAL
SLOPE TO DRAIN
SLOPE TO DRAIN
SLOPE TO DRAIN
178
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:11-DEC-20243:05:16PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19M11
LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
TLR
MECHANICAL
11843A1019M011.dgn
GENERAL NOTES:
eparker
RM
MISTY WOOD - WELL PROFILE - 11843A1013M302
10 1/4" = 1'-0"
MISTY WOOD WELL 19
DRAWINGS.ACCORDANCE WITH THE REQUIREMENTS DESCRIBED ON THE CONCRETE. THE CONCRETE AND REINFORCING SHALL BE IN PROVIDE 0.5-INCH MINIMUM CHAMFER ALL EXPOSED EDGES OF THE CASING AND SUPPORTED BY THE GROUT AROUND THE CASING. SHOWN, SHALL BE FULLY SEATED TO THE TOP OF THE SURFACE ENCASEMENT. AROUND THE FINISHED WELLHEAD ASSEMBLY AS
7. THE CONTRACTOR SHALL PROVIDE THE REINFORCED CONCRETE SHALL BE NSF APPROVED FOR POTABLE WATER USE.AIR IS CHARGED THROUGH THE SCHRADER VALVE. ALL MATERIALS TEE ON THE PUMP BASE. OR AS A BUBBLER TYPE INDICATOR WHEN A MANUAL TAPE THAT CAN BE DROPPED THROUGH THE TOP OF THE SHALL SERVE AS A BACKUP MEANS OF MEASURING WATER LEVEL VIA WATER VIA TRICKLE FLOW (TF) CONNECTION INTO THE WELL, AND TUBING SHALL SERVE A DUAL PURPOSE OF DIRECTING CHLORINATED SPACING TO A DEPTH OF 1 FOOT ABOVE THE BOWL ASSEMBLY. THE STRAPPED TO THE PUMP COLUMN WITH SST HOSE CLAMPS AT 10 FT
6. PROVIDE 0.75-INCH DIAMETER SEMI-RIGID POLYETHYLENE TUBING DRAWINGS. APPURTENANCES AS SHOWN AND AS SPECIFIED ON THESE RECOMMENDATIONS. PROVIDE ALL SPECIAL CONNECTIONS AND
5. INSTALL THE VERTICAL TURBINE PUMP AS PER THE MANUFACTURER'S THE PLUG.PROCESS. PROMPTLY REMOVE ANY MATERIALS THAT FALL IN ABOVE ENTRY OF FOREIGN MATERIALS DURING THE CONSTRUCTION ATMOSPHERE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY INFLATABLE PLUG NEAR THE SURFACE WHEN OPEN TO MATERIALS AT ALL TIMES DURING CONSTRUCTION BY THE USE OF A
4. THE WELL SHALL BE PROTECTED FROM THE ENTRY OF FOREIGN MATERIALS AND COMPONENTS. REPAIR, AND REPLACE ANY UNSATISFACTORY WELDS OR DAMAGED SPECIFICATIONS. THE CONTRACTOR IS RESPONSIBLE TO REMOVE, INSPECTIONS PER THE CONTRACT SCOPE OF WORK AND TECHNICAL SUBJECT TO FIELD WELDING AND SHOP WELDING PROCEDURES AND STEEL, SHALL BE PERFORMED BY A CERTIFIED WELDER AND IS FABRICATED WELLHEAD SHALL BE CONSIDERED TO BE STRUCTURAL
3. THE FIELD WELDING TO THE EXISTING WELLHEAD AND THE NEW EDGE. WELLHEAD. PROVIDE MINIMUM COVER OVER BAR AND CHAMFER INSTALL REINFORCED CONCRETE ENCASEMENT AROUND NEW AND MATERIAL TO EXISTING SOUNDING TUBE AND GRAVEL FILL PIPE. VALVES, AND LEVEL INSTRUMENT. MATCH NEW PIPE, THICKNESS, ENABLE THE EASY REMOVAL OF THE FLANGED FITTINGS, BOLTS, WELL HEAD AND OUT FROM UNDER THE CASING FLANGE AS TO FABRICATED TUBES TO BEND OUTWARD FROM THE CENTER OF THE SOUNDING TUBE AND GRAVEL FILL PIPES AND FIELD WELD ON NEW THICKNESS, AND MATERIAL TO EXISTING SST CASING. CUT EXISTING REQUIREMENTS. FIELD VERIFY AND MATCH NEW SST SIZE, COORDINATED WITH THE PUMP MOUNTING AND PIPING ORIENTATION PLACEMENT OF THE TOP AND THE BOLT HOLES SHALL BE SHALL BE WELDED PLUMB AND TRUE. THE SIZE DIMENSIONS AND WITH A CLEAN LEVEL/PLUMB EDGE. THE FABRICATED WELLHEAD SLAB AND WELLHEAD. CUT EXISTING SST CASING TO ELEVATION CONCRETE ENCASEMENT ENOUGH TO INSTALL CONCRETE BUILDING EXPOSE AND DEMOLISH EXISTING CONDUCTOR CASING AND ENCASEMENT EXTEND TO APPROXIMATELY EXISTING GRADE. CARBON STEEL CONDUCTOR CASING AND CONCRETE SEAL AND GRAVEL FILL TUBE EXTENDS ABOVE EXISTING GRADE. THE EXISTING
2. THE EXISTING STAINLESS STEEL WELL CASING, SOUNDING TUBE, AND LUHDORFF & SCALMANINI CONSULTING ENGINEERS, JANUARY 2024WELL CONSTRUCTION SEE "MISTY WOOD WELL AS-BUILTS, BY
1. THE EXISTING WELL WAS CONSTRUCTED BY OTHERS. FOR EXISTING OUTER DIAMETER OF 17.5".INSTALLED WITHIN THE CASING. THE 10" FOOT VALVE HAS A FLANGE CASING, AS WELL AS CONFIRM THAT THE 10" FOOT VALVE CAN BE SHALL CONFIRM THE INSIDE DIAMETER & ROUNDNESS OF THE WELL DIAMETER & LENGTH OF THE 10" FOOT VALVE ASSEMBLY. THIS TEST CASING BY PASSING A FULL-SCALE DUMMY GAGE WITH THE OUTER
6. CONTRACTOR SHALL VERIFY THE INTERNAL DIAMETER OF THE WELL SUBSTITUTED SUBJECT TO APPROVAL OF THE ENGINEER.ADVANCE PRODUCTS & SYSTEMS, LAFAYETTE, LA MAY BE POLYETHYLENE AND STAINLESS STEEL AS MANUFACTURED BY
5. COMMERCIALLY AVAILABLE CENTRALIZERS MADE OF
THE R.O. RELIABILITY WELL PUMP COLUMN PIPING.
4. CENTRALIZERS SHALL ALSO BE USED FOR THE INSTALLATION OF CLEAR CASING 1/2" ON ALL SIDES. SPACING ON PUMP COLUMN FLANGES. CENTRALIZERS SHALL
3. PROVIDE CENTRALIZER AT BOTTOM FLANGE AT PUMP AND AT 20' SST PIPING REQUIREMENTS.
2. SEE SCHEDULE, (SHEET 00GM05) AND PIPE SPECIFICATIONS FOR SPECIFICATIONS.
1. SEE VALVE TYPE SCHEDULE, (SHEET 00GM04) AND VALVE NOTES:
MISTY WOOD ASR WELL 19
AS-BUILT WELL PROFILE
MWMW-A
MWMW-B
MWMW-C BTTM 410' BTTM 345' SCRN 285' SCRN 270' FLTR PAC 302' SCRN 335' SCRN 320' FLTR PAC 311' FLTR PAC 353' SCRN 385' FLTR PAC 370' Misty Wood Well 19 2.5" Dia. Sch 80 PVC, typical all BTTM 295' FLTR PAC 409' FLTR PAC 260' SCRN 400' 118.0' BGS Static Water Level 138.0' BGS Pumped Water Level, (20.0 ft Drawdown @ 2,700 gpm) 158.0' BGS Regional Adjustment 198.0' BGS Minimum Submergence 208.0' BGS Baski Downhole Control Valve 225.0' BGS Straight Column Pipe 235.5' BGS Pump Bowls 240.5' BGS Straight Column Pipe 242.0' BGS Foot Check Valve 245.0' BGS Cone Strainer 2.5' AGS Top Flange of Well Casing 0.0' BGS/AGS Existing Grade 3.5' AGS CL Discharge Head Submersible sample pump Level sensor
REG I ST ERED PROFESS I ONA L ENG I NEER ST EPHEN BE L S ER
S T A T E O F CA L I FOR N I A
M E C H A N I C A L
M 40713
FLANGE 78
4 '-0"
4'-0"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:13-DEC-20242:03:49PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19M12
LASTSAVEDBY:
PROJECT NO. FILE NAME:
MED
DPF
MECHANICAL
11843A1019M012.dgn
SECTIONS AND DETAILS 79
GENERAL NOTES:
MISTY WOOD - MONITORING WELL
eparker
S- R 1' = 1 1/2"
11843A1009M402
EQUIPMENT REMOVAL, TYPWIRE AND TUBING TO FACILITEPROVIDE EXTRA LENGTH OFPER PUMP SUPPLIER, TYPDISCHARGE HOSESAMPLE PUMPPVC CASING, TYPEX 2.5" SCH 40LOCKING COVERCASING W/ HINGEDEX 16" STEEL GROUND, TYPSST ABOVE1" SAMPLE,
EACH 2.5" MONITORING WELL16" STL CASING, WITH THREEEX - NESTED MONITORING WELL,
EX TRAFFIC BOLLARDS, TYP
EX CONCRETE HOUSEKEEPING PAD
1" SPARE SAMPLE LINE
PREFORMED CHANNEL PIPE SUPPORT, TYP
BELOW GROUND, TYP1" SAMPLE SCH 80 PVC
TYP
MP218
TYP
EM211
(SIM)
TERMINAL BOX
REFER TO ELECTRICAL SPECIFICATIONSCONDUIT BELOW GROUND, TYP.
SINGLE RECEPTACLES
BELOW GROUND, TYP1" SAMPLE SCH 80 PVC
SEAL PENETRATION, TYP
11843A1009M402
1' = 1 1/2"
S- EX GRADE EX 16" STEEL CASING EX 2.5" SCH 40 PVC CASING, TYP
HOUSEKEEPING PADEX CONCRETE CONDUIT
1" SAM
PIPE SUPPORT, TYPPREFORMED CHANNEL
TERMINAL BOX
REFER TO ELECTRICAL SPECIFICATIONSABOVE GROUND CONDUITREFER TO ELECTRICAL SPECIFICATIONSBELOW GROUND CONDUIT
TO PUMP ROOMSTRUCTURE CONDUITSSAMPLE TO AIR-GAP
TOP FLANGE
1 19C02
11843A1019M603
2 19C02
11843A1019M604
MONITORING SAMPLE LINE
WITH CLASP FOR RECEPTACLENEMA 3R/4X PADLOCK
208V/1-P/60Hz, OR EQUAL.INC. THE PUMP SHALL BE GRUNDFOS MODEL 22SQE07-120, FT OF BORELINE HOSE AS MANUFACTURED BY HOSE SOLUTIONS, COMPLETE WITH 200 FT OF SUBMERSIBLE POWER CABLE AND 150 BE RATED AT 8 GPM AT 140 FT TDH, AND SHALL BE PROVIDED DEPTH OF 150 FT BLS USING 1" BORELINE HOSE. THE PUMP SHALL
5. PROVIDE A 3/4 HP SST SUBMERSIBLE SAMPLE PUMP, TO BE SET AT A MEASUREMENTS.) REMOVED TO PROVIDE ACCESS FOR PERIODIC WATER LEVEL NPT THREADED AND PLUGGED HOLE AS SHOWN. (THE PLUG CAN BE NPT THREADED NIPPLE CONNECTION TO AIR RELEASE VALVE AND A
4. FOR MONITOR WELL TUBES A & B - PROVIDE A SST FLANGE WITH WELLHEAD PRESSURE.PROVIDE A PRESSURE-TIGHT CABLE FITTING RATED FOR 20 PSI WITH THE INSTRUMENTATION AND CONTROL SYSTEM PACKAGE. SUBMERSIBLE WATER LEVEL TRANSDUCER LT~55 AS PROVIDED
3. FOR STORAGE ZONE MONITOR WELL TUBE C - INSTALL THE
PRESSURE OF 20 PSI. RECHARGE OPERATIONS AND SHALL BE CAPABLE OF A WELLHEAD WELLHEAD ASSEMBLY WILL BE UNDER PRESSURE DURING ASR MANUALLY MEASURING THE WATER LEVEL IN THE WELL. THE ALSO BE EASILY REMOVABLE TO FACILITATE A DROP TAPE FOR CONNECTION FOR AIR RELEASE VALVE ASSEMBLY WHICH SHALL CABLE OPENING FOR WATER LEVEL PROBE, D) 1/2 " NPT THREADED CABLE OPENING FOR PUMP POWER CABLE, C) PRESSURE SEALED AND THE 1" SAM-PVC DISCHARGE PIPING, B) PRESSURE SEALED CONNECTION BETWEEN BORELINE HOSE FROM THE SAMPLE PUMP SHOWN. TUBE C SHALL INCLUDE THE FOLLOWING: A) 1" SST PER THE DETAILS ON THIS DRAWING WITH HOLES AND TAPS AS MONITOR WELL.) PROVIDE A MATCHING 316 SST BLIND FLANGE AS SHALL BE THREADED, DO NOT USE SOLVENT WELDED PVC ON STAGGERED HEIGHT PATTERN AS SHOWN. (ALL CONNECTIONS INSTALL A 316 SST TOP FLANGE FOR EACH TUBE IN THE CASING TUBES AND TERMINATE ABOVE CONCRETE SLAB AND EXISTING GRADE WITH NPT THREADED ENDS. EXTEND THE PVC AND WERE EXTENDED APPROXIMATELY 6-INCHES ABOVE THE
2. THE MONITOR WELL CASING TUBES WERE INSTALLED BY OTHERS, REMOVAL. ALL FASTENERS SHALL BE TYPE 316 SST. .ANCHORS WITH SECURITY PATTERN TO INHIBIT TAMPERING AND ENCLOSURE TO THE CONCRETE SLAB USING 1#2" X 4" EXPANSION OPENING ENCLOSURE AS SHOWN ON DRAWING M18. MOUNT THE
1. A LOCKABLE, FABRICATED ALUMINUM, HINGED CLAM-SHELL
LOCATIONS AND DEPTHSPUMP AND LEVEL SENSORTHE TWO SUBMERSIBLESEE P&ID DRAWINGS FOR
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE-LINE SYMBOLS
DUPLEX RECEPTACLEQUADRUPLEX RECEPTACLEDUPLEX RECEPTACLE w/SPLIT WIRE WELDING RECEPTACLESPECIAL PURPOSE RECEPTACLETWIST LOCK RECEPTACLE TELEPHONE OUTLETDATA COMMUNICATIONS OUTLET LUMINAIRE IDENTIFICATION LUMINAIRE, EMERGENCY/EXIT BATTERY-POWEREDLUMINAIRE, EMERGENCY BATTERY-POWERED REMOTE(PERTAINS ONLY TO SHEET WHERE NOTE IS FOUND)LUMINAIRE, EMERGENCY BATTERY-POWEREDLUMINAIRE, SURFACE OR PENDANT MOUNTEDLUMINAIRE, FLOOD/SPOTLUMINAIRE, EXIT ONE OR TWO FACES AS INDICATED. ARROW POINTS IN DIRECTION OF EGRESS.2' X 2' LAY-IN TROFFER2' X 4' LAY-IN TROFFERLUMINAIRE POLE MOUNTED
PHOTOCELL
MOTOR
EQUIPMENT/INSTRUMENT LOCATOR
EXPOSED CONDUITEXPOSED CONDUIT HIDDEN BEHIND WALLS,FLOORS OR OTHER STRUCTURESUNDERGROUND CONDUIT, DIRECT BURIEDCONDUIT VERTICAL CHANGE IN DIRECTIONJUNCTION BOXCONDUIT SEAL
MEDIUM VOLTAGE DISCONNECT SWITCH NON-FUSED CUT OUTMEDIUM VOLTAGE DISCONNECTING FUSE SINGLE FUSE CUT OUTMEDIUM VOLTAGE DISCONNECTING FUSE DOUBLE FUSE CUT OUTMEDIUM VOLTAGE SINGLE FUSEMEDIUM VOLTAGE DOUBLE FUSEMEDIUM VOLTAGE FUSELIVE FRONT TERMINATORMEDIUM VOLTAGE ELBOW
UTILITY METER
CAPACITORBATTERYLIGHTNING ARRESTERGROUND
AMPERE TEST POINT
VOLTAGE TEST POINT
GROUNDED WYE CONNECTION
DELTA CONNECTION
GROUND ROD
SOLID STATEMULTIFUNCTION METER
GROUND ROD AND GROUND WELL
IDENTIFICATION SYMBOLS MEDIUM VOLTAGE LOW VOLTAGE MISCELLANEOUS
GROUNDING
LUMINAIRES
SWITCHES/RECEPTACLES RACEWAY
LUMINAIRE, WALL MOUNTEDCONDUIT IDENTIFICATION
XXXX = CONDUIT NUMBER,
REFER TO CONDUIT SCHEDULE
APPROXIMATE DIMENSIONS
EQUIPMENT ENCLOSURE
MOV-ELBOW ARRESTERMEDIUM VOLTAGE CONTACTORMEDIUM VOLTAGE STARTER
KIRK KEY INTERLOCK
abc
FIRE ALARM CONTROL PANEL
CONDUIT SIZE AND CONDUCTORS
IN FLOOR QUADRUPLEX RECEPTACLEIN FLOOR DUPLEX RECEPTACLE
ENGINE-GENERATOR RATINGS AS INDICATED ON
THE DRAWINGS
CURRENT TRANSFORMER WITHSHORTING TERMINAL BLOCK
DISCONNECT SWITCH LOW VOLTAGE CIRCUIT BREAKER AUXILIARY OPERATOR * = S = SHUNT TRIP
= G = GROUND FAULT INTERRUPTER = V = SOLENOID KEY RELEASE
CIRCUIT BREAKER, MEDIUM VOLTAGE ANSI RELAY DEVICE
52 a
b
a
b
b
abcde
a
f
c
d
e
J
FACP
ba
HP
~
G
cbade
a
b
a
b
ATP
SSM
VTP
*
b
B
A
CONDUIT IN SLAB
bc
a
DRAWOUT CONNECTION
fg
h
TRANSFORMER
a = DEVICE I.D. b = KVA RATINGc = NUMBER OF PHASESd = PRIMARY VOLTAGEe = SECONDARY VOLTAGEf,g= CONNECTION TYPE SYMBOLh = IMPEDANCE
PACKAGED EQUIPMENTLOAD RATING AS INDICATED
c d
POTENTIAL TRANSFORMER
a = QUANTITYb = RATIOc,d = CONNECTION TYPE SYMBOL
a
b
2 = DOUBLE POLE SWITCH
3 = THREE-WAY SWITCH
4 = FOUR-WAY SWITCH
K = KEY OPERATED SWITCH
F = SWITCH AND FUSESTAT HOLDER
P = SWITCH AND PILOT LIGHT
T = THERMOSTAT
D = DIMMER SWITCH
L = LOW VOLTAGE LIGHT SWITCH
M = MANUAL MOTOR STARTER
SINGLE POLE SWITCH
ab = DEVICE SWITCHED DESIGNATION
= CIRCUIT DESIGNATION
SWITCH AND SINGLE RECEPTACLE
DISCONNECT SWITCH
LOW VOLTAGE CIRCUIT BREAKER COMBINATION STARTERWITH CONTROL POWER TRANSFORMER
SPD SURGE PROTECTIVE
DEVICE
UNDERGROUND GROUND CABLE
ba
ab
ba
ba
baba
a
a
PE
c
ab
a
B
K
LOAD BANK
XXXX
CONDUIT CAPCONDUIT TEE
ARE LABELED LEFT TO RIGHT OR TOP TO BOTTOM.
X
c
b a
BREAK AND CONTINUATION IN CONDUIT RUN
MEDIUM VOLTAGE TEE
FIRE ALARM
INDICATES KEYNOTE X XEQUIPMENT AND INSTRUMENT IDENTIFICATION #4/0 SDBC UNLESS OTHERWISE NOTED
UNLESS OTHERWISE NOTED, GROUPED CONDUITS
d
3P = THREE POSITION SWITCH
OCCUPANCY SENSOR
c
b a
X
c = TYPE
REFER TO ABBREVIATIONS LEGEND
OR IN DUCT BANKDUCT BANKSHOWN ON DUCT BANK SECTIONS
= CIRCUIT DESIGNATION
= DEVICE SWITCHED FROM
= MOUNTING HEIGHT IN FEET TO
BOTTOM OF FIXTURE
FOR ALL OTHER DESIGNATIONS.
A = TYPE, REFER TO DISCONNECT SCHEDULE
= REFERENCE LIGHTING CONTROL COMPONENT SCHEDULE= CIRCUIT DESIGNATION= DEVICE SWITCHED DESIGNATION= MOUNTING HEIGHT IN FEET TO BOTTOM OF SENSOR Xabc
= CIRCUIT DESIGNATION
b = DEVICE TYPE DESIGNATIONa
= CIRCUIT DESIGNATION
ba
= DISCONNECT TYPE
a = AMP RATING
a
= CIRCUIT BREAKER NUMBER= FRAME SIZE= ANSI DEVICE FUNCTION= QUANTITY baab
TYPE AS NOTED
FUSED DISCONNECT SWITCH
MCP = MOTOR CIRCUIT PROTECTORTM = THERMAL MAGNETICSS = SOLID STATE
FRAME SIZE UNLESS INDICATED)
(AT = AMP TRIP)(AC = MCP CONTINUOUS RATING)
a = TYPEb = FRAME SIZE (MANUFACTURER TO DETERMINEc = NUMBER OF POLESd = TRIP SETTINGe = DESIGNATION f = INTERRUPTING RATING
A = TYPE, REFER TO DISCONNECT SCHEDULEb = FUSE RATINGB = TYPE, REFER TO DISCONNECT SCHEDULEa = CIRCUIT BREAKER DISCONNECT,b = STARTER TYPEc = NEMA STARTER SIZEd = OVERLOAD FULL LOAD AMPS AS NOTEDHP = HORSEPOWER RATINGa = RATED LOADb = UNIT(HP, KW, KVA) AS INDICATEDa = QUANTITYb = RATIOa = KVA/KWb = VOLTAGE/CONNECTIONc = PHASEd = WIREe = PF a
MOTOR STARTER/DRIVES:
b
c
a = DEVICE TYPE
bc
LINEAR FIXTURE
N = NETWORKED SINGLE OR
MULTIPLE SWITCH LOCATIONS
= INPUT OPTIONS= OUTPUT OPTIONS
VFD-6 = 6-PULSE VFDVFD-18 = 18-PULSE VFDRVSS = REDUCED VOLTAGE SOLID
STATE STARTER
==
RVAT REDUCED VOLTAGE AUTO
TRANSFORMER
a/B DEVICE WITH BYPASS
STARTER. REFER TOTHE SPECIFICATIONS
===
DV/DT = Dv/dt FILTER
=
LL LINE REACTORPHF PASSIVE HARMONIC FILTERLR LOAD REACTORSWF SINE WAVE FILTERFOR STARTER DEFINITIONS.REFER TO THE SPECIFICATIONS X
LUMINAIRE SCHEDULE
= LUMINAIRE TYPE, REFER TO THE
VFD-RH = REDUCED HARMONIC VFD
(18-PULSE OR ACTIVE FRONT ENDAS DEFINED IN THE SPECIFICATIONS) DEDICATED RECEPTACLE ba
EQUIP #
A
FIBER OPTIC CABLES
N = NUMBER OF INDIVIDUAL FIBERS
FO/N
INDIVIDUAL CONDUCTORS
U = NUMBER OF PARALLEL RUNS
U{3-X (Ø) & 1-X (G)}
(G) = DESIGNATES GROUND CONDUCTORS
Z = SIZE OF CONDUCTORS
1 = QUANTITY
1-Z (G) (WHERE INDICATED):
(N) = DESIGNATES NEUTRAL CONDUCTORS
Y = SIZE OF CONDUCTORS
1 = QUANTITY
1-Y (N) (WHERE INDICATED):
(Ø) = DESIGNATES PHASE CONDUCTORS
X = SIZE OF CONDUCTORS
3 = QUANTITY
3-X (Ø):
W"C (WHERE INDICATED): W = CONDUIT TRADE SIZEW"C-(3-X (Ø), 1-Y (N) & 1-Z (G))
MULTI CONDUCTOR CABLES
X = SIZE OF CONDUCTORS
N/C = NUMBER OF PHASE CONDUCTORS IN THE CABLE
MC = MULTICONDUCTOR CABLE
U = NUMBER OF PARALLEL RUNS
U{[N/C-X (Ø) & INTEGRAL (G)]:MC}
TWISTED SHIELDED TRIPLETS
3/C#16S = THREE CONDUCTOR, 16 GAUGE,
K (WHERE INDICATED) = NUMBER OF TRIPLETS
K/3/C#16S
TWISTED SHIELDED PAIR
2/C#16S = TWO CONDUCTOR, 16 GAUGE,
K (WHERE INDICATED) = NUMBER OF PAIRS
K/2/C#16S
VFD CONDUCTORS
VFD = VFD CABLEX = SIZE OF CONDUCTORS
N/C = NUMBER OF PHASE CONDUCTORS IN CABLE
U = NUMBER OF PARALLEL RUNS
U{[N/C-X (Ø) & INTEGRAL (G)]:VFD}
WP= WEATHER PROOF
= NETWORK SWITCH
CAMERA
PlotDate:03-DEC-20249:34:51AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 11843A1000GE01.dgn
LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ELECTRICAL 00GE01
LEGEND
79 nself
RM
80 178
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
ABBREVIATIONS
NOTES:
94 TRIPPING OR TRIP-FREE RELAY93 FIELD-CHANGING CONTACTOR 92 VOLTAGE AND POWER DIRECTIONAL RELAY 91 VOLTAGE DIRECTIONAL RELAY 90 REGULATING DEVICE 89 LINE SWITCH 88 AUXILIARY MOTOR OR MOTOR GENERATOR 87 DIFFERENTIAL PROTECTIVE RELAY 86 LOCKOUT RELAY 85 PILOT COMMUNICATIONS, CARRIER OR PILOT-WIRE RELAY84 OPERATING MECHANISM 83 AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY
P PHASE PROTECTION
V VOLTAGE
T TRANSFORMER PROTECTION
(RELAY COIL CONNECTED IN RESIDUAL CT CIRCUIT)
N GROUND FAULT PROTECTION
M MOTOR PROTECTION
L LINE PROTECTION
(RELAY CT IN TOROIDAL OR GROUND SENSOR TYPE)
GS GROUND FAULT PROTECTION
(RELAY CT IN A SYSTEM NEUTRAL CIRCUIT OR GENERATOR PROTECTION)
G GROUND FAULT PROTECTION
B BUS PROTECTION
A ALARM ONLY
ABBREVIATIONS
POWER DEVICE FUNCTION NUMBERS
POWER DEVICE FUNCTION NUMBERS
COMMONLY USED SUFFIX LETTERS APPLIED TO
SYM SYMMETRICALSWGR SWITCHGEAR SWBD SWITCHBOARD SW SWITCH STB SHORTING TERMINAL BLOCK SS SOLID STATE SPKR SPEAKER SPST SINGLE POLE SINGLE THROW SPDT SINGLE POLE DOUBLE THROW SPD SURGE PROTECTIVE DEVICE SP SINGLE POLESM SURFACE MOUNTED SLT SEALTIGHT LIQUIDTIGHT FLEXIBLE CONDUIT SFL SUB FEED LUGS SDBC SOFT DRAWN BARE COPPER SC SHORT CIRCUITSA SURGE ARRESTER S SHIELD / SHORT-TIMERVSS REDUCED VOLTAGE SOLID STATERVNR REDUCED VOLTAGE NON-REVERSING RVAT REDUCED VOLTAGE AUTO TRANSFORMER RMS ROOT MEAN SQUARED RF RADIO FREQUENCYREV REVERSE RECPT RECEPTACLE RAC RIGID ALUMINUM CONDUITPWR POWERPVC POLYVINYL CHLORIDE RIGID PLASTIC CONDUIT PT POTENTIAL TRANSFORMERPRI PRIMARY PPX POWER PANEL NO. X PNL PANEL PH PHASE PFR PHASE FAILURE RELAY PFCC POWER FACTOR CORRECTION CAPACITORPF POWER FACTOR PE PHOTOCELL PCM PROCESS CONTROL MODULEPCS PVC COATED GALVANIZED STEEL CONDUIT PB PUSHBUTTON / PULL BOX PA PUBLIC ADDRESS P POLE OL OVERLOAD RELAY OH OVERHEAD O OPEN OR OPENED NP NAMEPLATE NO NORMALLY OPEN NL NIGHT LIGHT NFC NONMETALLIC FLEXIBLE CONDUIT NEC NATIONAL ELECTRICAL CODE NC NORMALLY CLOSED N NEUTRALMW MEGAWATT MVS MEDIUM VOLTAGE SWITCHMVA MEGAVOLT-AMPERES MV MEGAVOLT MTS MANUAL TRANSFER SWITCH MTR-X MOTOR NO. X MTO MANUAL THROW OVER MSP MOTOR STARTING PANEL MS-X MOTOR STARTER NO. X MPR MOTOR PROTECTION RELAYMOV METAL OXIDE VARISTORMOD MOTOR OPERATED DAMPER MLO MAIN LUGS ONLY MH MANHOLE / MOUNTING HEIGHTMCP MOTOR CIRCUIT PROTECTOR MCC - X MOTOR CONTROL CENTER NO. X MCA MOTOR CIRCUIT AMPSMA MILLIAMPERE M-X MOTOR CONTROLLER NO. X LVL LEVELLV LOW VOLTAGE LTG LIGHTING LP - X LIGHTING PANEL NO. X LP LIGHT POLE LL LEAD-LAG LOAD REACTOR LCP- X LOCAL CONTROL PANEL NO. X LC LIGHTING CONTACTOR LBL LABEL LA LIGHTNING ARRESTOR L-G LINE-GROUND L-B LINE-BUS L LONG-TIME KWH KILOWATT HOURKWD KILOWATT DEMAND KW KILOWATT KVAR KILOVAR (REACTANCE) KVA KILOVOLT AMPERE KV KILOVOLT KA KILOAMP K KEY INTERLOCK J JUNCTION BOX 82 DC LOAD MEASURING RECLOSING RELAY81 FREQUENCY RELAY 80 FLOW SWITCH 79 AC RECLOSING RELAY 78 PHASE-ANGLE MEASURING RELAY 77 TELEMETERING DEVICE76 DC OVERCURRENT RELAY 75 POSITION CHANGING MECHANISM 74 ALARM RELAY 73 LOAD-RESISTOR CONTACTOR 72 DC CIRCUIT BREAKER 71 LIQUID LEVEL SWITCH 70 RHEOSTAT 69 PERMISSIVE CONTROL DEVICE 68 BLOCKING OR OUT OF STEP RELAY 67 AC DIRECTIONAL OVERCURRENT RELAY 66 NOTCHING OR JOGGING DEVICE 65 GOVERNOR 64 GROUND DETECTOR RELAY 63 PRESSURE SWITCH 62 TIME-DELAY STOPPING OR OPENING RELAY 61 DENSITY SWITCH OR SENSOR60 VOLTAGE OR CURRENT BALANCE RELAY 59 OVERVOLTAGE RELAY 58 RECTIFICATION FAILURE RELAY 57 SHORT-CIRCUITING OR GROUNDING DEVICE 56 FIELD APPLICATION RELAY 55 POWER FACTOR RELAY 54 TURNING GEAR ENGAGING DEVICE53 FIELD EXCITATION RELAY52 AC CIRCUIT BREAKER 51 AC TIME OVERCURRENT RELAY 50 INSTANTANEOUS OVERCURRENT RELAY 49 MACHINE OR TRANSFORMER THERMAL RELAY 48 INCOMPLETE SEQUENCE RELAY 47 PHASE-BALANCE OR PHASE-SEQUENCE VOLTAGE RELAY 46 REVERSE-PHASE OR BALANCE CURRENT RELAY 45 ABNORMAL ATMOSPHERIC CONDITION MONITOR 44 UNIT SEQUENCE STARTING RELAY 43 MANUAL TRANSFER OR SELECTOR DEVICE 42 RUNNING CIRCUIT BREAKER 41 FIELD CIRCUIT BREAKER 40 FIELD RELAY 39 MECHANICAL CONDITION MONITOR 38 BEARING PROTECTIVE DEVICE 37 UNDERCURRENT OR UNDERPOWER RELAY 36 POLARITY DEVICE35 BRUSH-OPERATING OR SLIP-RING SHORT-CIRCUITING DEVICE 34 MASTER SEQUENCE DEVICE 33 POSITION SWITCH32 DIRECTIONAL POWER RELAY 31 SEPARATE EXCITATION DEVICE 30 ANNUNCIATOR RELAY 29 ISOLATING CONTACTOR 28 FLAME DETECTOR 27N GROUND FAULT UNDERVOLTAGE RELAY 27 UNDERVOLTAGE RELAY 26 APPARATUS THERMAL DEVICE 25 SYNCHRONIZING OR SYNCHRONISM-CHECK DEVICE 24 VOLTS PER HERTZ RELAY 23 TEMPERATURE CONTROL DEVICE 22 EQUALIZER CIRCUIT BREAKER 21 DISTANCE RELAY 20 ELECTRICALLY OPERATED VALVE 19 STARTING-TO-RUNNING TRANSITION CONTACTOR 18 ACCELERATING OR DECELERATING DEVICE 17 SHUNTING OR DISCHARGE SWITCH16 DATA COMMUNICATIONS DEVICE15 SPEED OR FREQUENCY MATCHING DEVICE 14 UNDER-SPEED DEVICE 13 SYNCHRONOUS-SPEED DEVICE 12 OVER-SPEED DEVICE 11 MULTIFUNCTION DEVICE10 UNIT SEQUENCE SWITCH 9 REVERSING DEVICE
8 CONTROL POWER DISCONNECTING DEVICE
7 ANODE CIRCUIT BREAKER
6 STARTING CIRCUIT BREAKER
5 STOPPING DEVICE
4 MASTER CONTACTOR
3 CHECKING OR INTERLOCKING RELAY
2 TIME-DELAY STARTING OR CLOSING RELAY
1 MASTER ELEMENT
TCM - TRIP CIRCUIT MONITOR
SER - SEQUENCE OF EVENTS RECORDER
RTU - REMOTE TELEMETRY UNIT/REMOTE TERMINAL UNITRIO - REMOTE I/O DEVICE
PQM - POWER QUALITY MONITORPMU - PHASOR MEASUREMENT UNITPDC - PHASOR DATA CONCENTRATOR
MET - SUBSTATION METERING
LGC - SCHEME LOGIC
HST - HISTORIANHMI - HUMAN MACHINE INTERFACEHIZ - HIGH IMPEDANCE FAULT DETECTOR
ENV - ENVIRONMENTAL DATA
DFR - DIGITAL FAULT RECORDERDDR - DYNAMIC DISTURBANCE RECORDER
CLK - CLOCK OR TIMING SOURCE
AFD - ARC FLASH DETECTOR
1. REFER TO SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL ABBREVIATIONS.
INTERCOM INTERCOMMUNICATION INT INTERLOCK INST INSTANTANEOUS IMC INTERMEDIATE METAL CONDUIT IJB INSTRUMENT JUNCTION BOXIC INTERRUPTING CAPACITYI INSTANTANEOUS / INTERMITTENT LOAD
HZ HERTZHVAC HEATING/VENTILATION/AIR CONDITIONING HV HIGH VOLTAGE HSTAT HUMIDISTAT HR HOUR HPS HIGH PRESSURE SODIUM HP HORSEPOWER HF HIGH FREQUENCY H HOT-LEG
GFR GROUND FAULT RELAY GFI GROUND FAULT INTERRUPTER (BREAKER) GFCI GROUND FAULT CIRCUIT INTERRUPTER (RECEPTACLE) GRC GALVANIZED STEEL RIGID CONDUIT GEN GENERATORG GROUND / EQUIPMENT GROUND / GROUND FAULT
FWD FORWARDFVR FULL VOLTAGE REVERSING FVNR FULL VOLTAGE NON-REVERSING FU SW FUSED SWITCHFU FUSEFREQ FREQUENCY FRC FIBERGLASS RIGID CONDUIT FO FIBER OPTICFLX FLEXIBLE CONDUIT FLA FULL LOAD AMPS FDR FEEDERFACP FIRE ALARM CONTROL PANEL FA FIRE ALARMF SUB-FED
ETM ELAPSED TIME METEREP EXPLOSION PROOFENT ELECTRICAL NON-METALLIC TUBINGENG ENGINEENCL ENCLOSURE EMT ELECTRICAL METALLIC TUBING EM EMERGENCYE/G EMERGENCY GENERATOR DS DOOR SWITCH DPST DOUBLE POLE SINGLE THROW DPDT DOUBLE POLE DOUBLE THROW DM DEMAND METERDISC DISCONNECT SWITCH DEMO DEMOLITIONDCU - X DISTRIBUTED CONTROL UNIT NO. X DCS DISTRIBUTED CONTROL SYSTEM DC DIRECT CURRENT
CW CLOCKWISE / COOL WHITE CV CONTROL VALVE CT CURRENT TRANSFORMER CS CONTROL SWITCH CR CONTROLLED RECEPTACLECPT CONTROL POWER TRANSFORMER COMM COMMUNICATION COM COMMON COAX COAXIAL CABLE CKT CIRCUIT CCW COUNTER CLOCKWISECCTV CLOSED CIRCUIT TELEVISION CB CIRCUIT BREAKER C CONDUIT / CONTINUOUS LOAD
BRF BELOW RAISED FLOOR BKR BREAKER BHP BRAKE HORSEPOWER BFG BELOW FINISHED GRADE BAT BATTERY B BELL
AWG AMERICAN WIRE GAGEAUX AUXILIARY AUTO XFMR AUTOMATIC TRANSFORMER ATS AUTOMATIC TRANSFER SWITCH ATP AMMETER TEST POINT ATO AUTOMATIC THROW OVER AT AMP TRIP ASYM ASYMMETRICAL AS AMMETER SWITCH ARM ARMORED CABLE APU AUXILIARY POWER UNITANT ANTENNA ANN ANNUNCIATOR AM AMMETERAIC AMP INTERRUPTING CAPACITY AFC AUTOMATIC FREQUENCY CONTROL AF AMP FRAME ACTR ACTUATOR ACK ACKNOWLEDGE AC ALTERNATING CURRENT ABS ABSOLUTEA AMP XFMR TRANSFORMER WP WEATHER PROOF WT WATER TIGHT W WATT / WEST VTP VOLTAGE TEST POINT VT VOLTAGE TRANSFORMER VS VOLTAGE SWITCHVR VOLTAGE REGULATOR VP VAPORPROOF VM VOLTMETERVHF VERY HIGH FREQUENCY VFD VARIABLE FREQUENCY DRIVE VCP VENDOR CONTROL PANELVAR VARMETERVA VOLT AMPERE V VOLT UVR UNDER VOLTAGE RELAYUPS UNINTERRUPTIBLE POWER SUPPLY UNG UNGROUNDEDUHF ULTRA HIGH FREQUENCY TSTAT THERMOSTATTS2W TWO SPEED SEPARATE WINDING TS1W TWO SPEED CONSEQUENT POLE, ONE WINDING TS TEMPERATURE SWITCH TP TWISTED PAIR TM THERMAL MAGNETIC TJB TERMINAL JUNCTION BOX TERM TERMINAL TENV TOTALLY ENCLOSED NON-VENTILATED TEFC TOTALLY ENCLOSED FAN COOLED TE TOTALLY ENCLOSED TD TEMPERATURE DETECTOR RELAY TC THERMOCOUPLE / TIME CLOCK / TRAY CABLE TB - X TERMINAL BLOCK - UNIT X TACH TACHOMETER PlotDate:03-DEC-20249:34:51AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 11843A1000GE02.dgn
LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ELECTRICAL 00GE02
ABBREVIATIONS
tmorabito
80 81 178
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PROCESS SWITCHES HAND SWITCHES RELAYS TERMINAL BLOCKS I/O MISC
CLOSE ON RISING LEVEL
FLOAT SWITCH
OPEN ON RISING LEVEL
FLOAT SWITCH
CLOSE ON RISING PRESSURE
PRESSURE SWITCH
OPEN ON RISING PRESSURE
PRESSURE SWITCH
CLOSE ON RISING TEMPERATURE
TEMPERATURE SWITCH
OPEN ON RISING TEMPERATURE
TEMPERATURE SWITCH
CLOSE ON INCREASE IN FLOW
FLOW SWITCH
OPEN ON INCREASE IN FLOW
FLOW SWITCH
OPEN ON RISING VIBRATION
VIBRATION SWITCH
CLOSE ON RISING VIBRATION
VIBRATION SWITCH
OPEN ON HIGH TORQUE
TORQUE SWITCH
THREE POSITION SELECTOR SWITCH TWO POSITION SELECTOR SWITCH
MUSHROOM HEAD PUSHBUTTONMAINTAINED CONTACT
PUSH-PULL PUSHBUTTONPULL CORD SWITCH
IN PLC/PCM PANEL
TERMINAL
IN MOTOR CONTROL CENTER
TERMINAL
IN LOCAL STARTER CONTROL PANEL
TERMINAL
AT FIELD DEVICE
TERMINAL
IN FIELD PANEL
TERMINAL
IN (USER CHOICE)
TERMINAL
DIGITAL BUS CONNECTOR
a = INPUT OR OUTPUT AS INDICATED
PLC DISCRETEDIGITAL BUS
SOLENOID
M = TYPEMETER UNIT MOTOR
CIRCUIT BREAKER
DISCONNECT
FUSE
* - MOTOR TAG I.D.
MOTOR WINDING HEATER
VARISTOR
CAPACITOR
RESISTOR
BATTERY
DIODE
OVERLOAD CONTACT
DRAWOUT CONNECTION
GROUND
LIGHTNING ARRESTOR
a = INPUT OR OUTPUT AS INDICATED
PLC ANALOG
IN RTU
TERMINAL
STOP-LOCKOUT PUSHBUTTON
SPRING-RETURN
SPACE HEATER
ELAPSED TIME METER
PADLOCK SWITCH
xoxxoxoo
ANALOG
a
DIGITAL
BUS
a
M
MWH-*
KI-*
ETM
HP
a
bc
d
H1 H3 H2 H4
X1 X2
xoo
CLOSE ON HIGH TORQUE
TORQUE SWITCH
NCTCNCTONOTCNOTO
CONTROL CONTACT
NORMALLY CLOSED
CONTROL CONTACT
NORMALLY OPEN
TIMED CLOSING
NORMALLY OPEN
TIME DELAY CONTACTTIMED OPENING
NORMALLY CLOSED
TIME DELAY CONTACTTIMED OPENING
NORMALLY OPEN
TIME DELAY CONTACTTIMED CLOSING
NORMALLY CLOSED
TIME DELAY CONTACT
LIMIT SWITCH
NORMALLY CLOSED
HELD OPEN LIMIT SWITCH
NORMALLY CLOSED
LIMIT SWITCH
NORMALLY OPEN
HELD CLOSED LIMIT SWITCH
NORMALLY OPEN
MOMENTARY PUSHBUTTON
NORMALLY OPEN
MOMENTARY PUSHBUTTON
NORMALLY CLOSED
TRANSFORMER
CONTROL POWER
HEATERS
MOTOR OVERLOAD
PROTECTION
TRANSIENT SURGE
CLOSED IN
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
x - DENOTES POSITION CONTACTS
CLOSED IN
CLOSED IN
CLOSED IN
d = DESCRIPTION
c = TIMING RANGE/SETTING
TDOFF - TIME DELAY ON DEENERGIZATION
b = TDON - TIME DELAY ON ENERGIZATION
R -MOTOR STARTER COIL - REVERSEF -MOTOR STARTER COIL - FORWARDH -MOTOR STARTER COIL - HIGH SPEEDL -MOTOR STARTER COIL - LOW SPEEDM -MOTOR STARTER COILTD -TIME DELAY RELAYCR -CONTROL RELAY a = TYPE
RELAY COIL
* = E -ETHERNET* = H2 -FOUNDATION FIELDBUS H2* = H1 -FOUNDATION FIELDBUS H1* = DP -PROFIBUS DP* = PA -PROFIBUS PA* = D -DEVICENET
INDICATORS
HORN
C = CLEARM = MAGENTAB = BLUEA = AMBERW = WHITEG = GREENR = RED a = LENS COLOR
BEACON
C = CLEARY = YELLOWB = BLUEA = AMBERW = WHITEG = GREENR = RED a = LENS COLOR
a PILOT LIGHTa
a
H
*
PlotDate:03-DEC-20249:35:37AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 11843A1000GE03.dgn
LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ELECTRICAL 00GE03
evandoorn
SCHEMATIC SYMBOLS
82 81
178
CLOSE
OPEN
4563 2
1 120VAC FROM PLCP UPS
120VAC
GND
480V
H1 H3 H2 H4
X1 X2
MOV
120V SEC480V PRI
VFD
RUNNING
A
YA-*A
MV
MV-*
CR
CR1-*
VFD
FAILED
xoo
HSB-*
VFD-BYPASS
xoox
MC
MC-*
1 CR
CR3-*
A
Y1-*
CR1-*
MC-*
RUNNING
ENET
2 xooxooAUTO
OFF
HAND
FORWARDRUNSTOPEMERGENCY
CR3-*
MV-*MV-*MV-*
MC-*MC-*MC-*
xo
RUN OFF
INPUTRTD
PHASE AMOTOR RTD
INPUTRTD
PHASE BMOTOR RTD
INPUTRTD
PHASE CMOTOR RTD
CR3-*
MC-*
MV-*
MODEHAND
WELL PUMPS WD34-PUMP-30101, WD34-PUMP-36101
E
#
CLOSE BUTTON.
1. TO RESET THE BREAKER, PRESS THE OPEN BUTTON AND THEN THE GENERAL NOTES:
KEY NOTES:
*
MAIN BREAKERS WD31-BKRX-30105, WD34-BKRX-36105
FAILED
WD34-HEAT-*
13E07, 19E07 13E07, 19E07
* = PA - PROFIBUS PA * = DP - PROFIBUS DP * = E - ETHERNET= DIGITAL BUS CONNECTOR= FIELD PANEL= FIELD= PLCP= MOTOR CONTROLLER
2. TERMINAL BLOCK LEGEND:
MANUFACTURER.DESCRIBED IN THE SPECIFICATIONS BASED ON THE SELECTED REQUIRED TO PERFORM THE OPERATION INDICATED HERE AS
1. SCHEMATICS SHOW FUNCTIONALITY. REVISE THE SCHEMATIC AS
FLOW SWITCH
120VAC
PRESSURE INPUTHIGH DISCHARGE LOW FLOW INPUTSEAL WATER
CR3-* SV-*
I/O MODULE
CIRCUIT BREAKER
xo
ON OFF
xoxo
B
Y1-*
MAINTENANCE
TM
MV-*MV-*MV-*
O.L.O.L.O.L.
COMMON
MODE
MAINTENANCE
HSNX-*
PSH-***
FSL-**
* = 30101,** = 30113,*** = 30107 WD34-PMP-30101* = 36101,** = 36113,*** = 36107 WD34-PMP-36101 INPUT
SIG COM
24VDC FROM PLCP
MOTOR OPERATOR
CIRCUIT OPERATOR
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:03-DEC-20249:35:04AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CAC
BLS
ELECTRICAL
11843A1000E01.dgn
CONTROL SCHEMATICS 1
1 00E01
82 RM
OWestbrook
83 178
3 M
O.L.
CØ
GND
H1 H3 H2 H4
X1 X2
PRIMARY FUSESCONTROL TRANSFORMER
MCP
480V
GND
120V SEC480V PRI
1Ø CONTROL TRANSFORMER
M
M-*
xoo
OFF
AUTO OLSoox
WHERE INDICATED
REMOTE DISCONNECT
M
O.L.
CØ
GND
H1 H3 H2 H4
X1 X2
PRIMARY FUSESCONTROL TRANSFORMER
MCP
480V
GND
120V SEC480V PRI
1Ø CONTROL TRANSFORMER
M
M-*
ON
xoo
OLS
WHERE INDICATED
REMOTE DISCONNECT
TSH
GENERAL NOTES:
*
# KEY NOTES:
PUMP ROOM EXHAUST FANS: WD37-FANX-30301, WD37-FANX-3630113E07, 19E07 4 13E07, 19E07CHEMICAL ROOM EXHAUST FANS: WD37-FANX-30302, WD37-FANX-36302 HAND
1 OFF
* = PA - PROFIBUS PA * = DP - PROFIBUS DP * = E - ETHERNET= DIGITAL BUS CONNECTOR= FIELD PANEL= FIELD= PLCP= MOTOR CONTROLLER
2. TERMINAL BLOCK LEGEND:
MANUFACTURER.DESCRIBED IN THE SPECIFICATIONS BASED ON THE SELECTED REQUIRED TO PERFORM THE OPERATION INDICATED HERE AS
1. SCHEMATICS SHOW FUNCTIONALITY. REVISE THE SCHEMATIC AS 1. HVAC SUPPLIER PROVIDED THERMOSTAT.
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:03-DEC-20249:35:22AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CAC
BLS
ELECTRICAL
11843A1000E02.dgn
CONTROL SCHEMATICS 2
00E02
83 OWestbrook
RM
84 178
LUMINAIRE SCHEDULE 4/22/2024
ITEM DESCRIPTION MOUNTING LAMP LUMINAIRE SPECIFICATIONS
METHOD QUANTITY TYPE MANUFACTURER CATALOG VOLTS VA
A IP65, IP66 & IP67 RATED; NEMA 4X RATED LENS AND HOUSING; 1500 PSI HOSE -DOWN; AMBIENT TEMPERATURE RATED FOR -35C TO 25C
SUSPENDED OR CEILING
AS NEEDED
N/A LED HOLOPHANE EMS L48 4000LM LPPFL MD 120 40K 80CRI 120 26 B IP65, IP66 & IP67 RATED; NEMA 4X RATED LENS AND HOUSING; 1500 PSI HOSE -DOWN; AMBIENT TEMPERATURE RATED FOR -35C TO 25C WITH EMERGENCY BACK-UP BATTERY PACK
SUSPENDED OR CEILING
AS NEEDED
N/A LED HOLOPHANE
EMS L48 4000LM LPPFL MD 120 40K 80CRI
E10WMCP
120 26
C IP55 RATED, UL WET LOCATION LISTED, RATED FOR -40C, PHOTOCELL WALL N/A LED HOLOPHANE WCNG P2 40K T3M 120 20KV BKSDP TMPS PR7 SF
PCLL RSBOR
120 39
D LED EXIT SIGN, CORROSION PROOF, EL94V-0 FLAME RATING, LOW ENERGY LED LAMP, 90 MIN
BATTERY BACK UP
WALL N/A LED HOLOPHANE QM LED R HO 120 9
DISCONNECT SCHEDULE 11/4/2024
TAG VOLTAGE POLES AMPS NEMA TYPE TYPE HORSEPOWER FUSE SIZE BREAKER AF/AT ACCESSORIES A 600 VAC 3P 30A 4X-NON-METALLIC FUSED
B 600 VAC 3P 100A 4X-NON-METALLIC FUSED
C 600 VAC 3P 30A 4X-SS FUSED
D 600 VAC 3P 30A 12 FUSED
E 600 VAC 3P 100A 4X-SS FUSED
S 120 VAC 1P 30A 12 FUSED
ACCESSORIES 1="B" TYPE ELECTRICAL INTERLOCK FOR POSITION INDICATION 2=INSULATED GROUNDABLE NEUTRAL KIT3=DRAIN AND BREATHER KIT WHEN OUTDOORS4=EARLY BREAK AUXILIARY CONTACT
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:03-DEC-20249:34:51AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CAC
EYV
ELECTRICAL
11843A1000E03.dgn
00E03
83 ELECTRICAL SCHEDULES
nself
RM
85 178
J
Plot Date: 12/5/2024 3:53:16 PM PROJECT NO.
LAST SAVED BY: FILE NAME: CAC TLM 13E01 85 ELECTRICAL CAMPUS OAKS ASR WELL ELECTRICAL SITE PLAN 11843A1013E01.dwgOWestbrook 0 0 5' 10' 20' SCALE: 1" = 10' WELL BUILDING UTILITY TRANSFORMER FIBER OPTIC HANDHOLE PB-E-1 PB-S-1 SEE A / 13E02 SEE B / 13E03 SEE C / 13E04 30A 13E05 GATE CARD READER KNOX BOX FIRE STROBE 30-S-760 30-S-765 GATE OPERATOR 30-S-761 TYP EM015 30-S-175 30-P-175 TYP EM015 REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 176 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 No. 20740 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION JB-S-140 1 # KEY NOTES: 1. 20A SINGLE RECEPTACLE. 2. APPROXIMATE LOCATION OF EXISTING FIBER OPTIC HANDHOLE AND CONDUIT STUB UPS (4"C-QTY 4, AND 2"C-QTY 1) TO BE RELOCATED. 3. MOVE EXISTING FIBER OPTIC HANDHOLE TO THIS LOCATION. 4. INTERCEPT EXISTING CONDUITS AT THIS LOCATION. ROUTE TO UTILITY TRANSFORMER AND FIBER OPTIC HANDHOLE. 5. PROVIDE 12' ALUMINUM ROUND STRAIGHT POLE FOR LICENSE PLATE READER CAMERAS. CAMERAS PROVIDED BY OTHERS. 30-S-751 30-P-401 30-S-752 TYP EM315 42WP,GFCI 44WP,GFCI 3 2 MONITORING WELL TYP EM015 4 30-E-761 TYP EM015 TYP EL506 5 86 178 T
T
KEY NOTES:
1. FUTURE WATER TREATMENT CONTROL PANEL.
#
GENERAL NOTES:
1. SEE DRAWING 13E01 FOR LOCATION OF FACILITY ON SITE PLAN.
FACP
WD08-CKEY-30900
WD08-NVRX-30301
WD34-VFDX-30101
TYP
EM118
WD37-HVAC-30101
CONTINUED ON
DWG 13E01
30G
13E05
30I
13E05
30H
13E05
30A
13E05
30C
30B 13E05
13E05
30F
13E05
30E
13E05
30D
13E05
TYP
EM001 (TYP)
WD31-XFMR-30107
WD31-LPXX-30108 WD31-MCCX-30100 WD31-SWBD-30105
WD31-PLCP-30101
PB-E-1
PB-S-1
TYP
EM001 (TYP)
30-S-751
TYP
EM015
WD08-NVRX-30300
CONTINUED ON
DWG 13E01
30-P-176 30-P-177
WD33-VFDX-30401 WD33-VFDX-30402
30-P-175
WD34-PUMP-30101
30-P-102
30-P-101
TYP
EM015
30-S-752
30-P-401
TYP
EM015
1 30-S-175
TYP
EM015
CONTINUED ON
DWG 13E01
30-E-511
30-E-512
30-E-513
30-F-001
30-E-524
30-E-525
30-E-526
30-E-527
30-P-013
30-P-012
30-P-011
30-P-010
30-E-520
30-E-521
30-E-522
30-E-523
30-E-761
30-E-503
30-E-504
30-E-501
30-E-502
30-E-510
CONTINUED ON
DWG 13E01
CONTINUED ON
DWG 13E01
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/10/2024 1:18:00 PM
R:\d1341482\11843A1013E801.rvt
13E02
CAMPUS OAKS ASR WELL
UNDERGROUND POWER AND CONTROL PLAN 87
ELECTRICAL
TLM
CAC
SCALE:
ENLARGED PLAN
1/4" = 1'-0"
A
13E01
178
T
T
S S
C
T
D
A
A
E
CC
B
SSS J
J
J
J
J
J
J
T
D
J
WD37-HVAC-30101
WD34-PITX-30109
WD34-PUMP-30101
WD34-MOVX-30130
WD34-LCPX-30101
WD34-PITX-30102
WD34-FITX-30104
WD34-MOVX-30140
WD34-FCVX-30150
WD34-MOVX-30160
WD34-LITX-30100
WD34-PDIT-30151
WD34-PSHH-30107
WD34-VCPX-30121
WD33-LCPX-30310
WD37-FSHX-30001
WD33-PLCP-30210
1 13E03
WD08-HMIX-30103
WD37-HEAT-30202
WD37-HEAT-30203
WD37-FANX-30302
JB-S-103
JB-S-152
WD33-AITX-30205
WD37-FANX-30301
WD33-AITX-30206
WD33-AITX-30307
WD37-TSHX-30301
GENERATOR CONNECTION CABINET
WD34-TANK-30305 WD33-LCPX-30202
JB-S-153
JB-S-100
WD37-HEAT-30201
30-P-620
30-P-621
JB-S-150
30-S-237
30-S-233
30-S-236
30-S-230
30-S-229
WD34-FSLX-30113
WD34-SOVX-30101
30-S-156
30-P-234
30-S-160
30-S-154
30-S-153
30-S-157
30-S-152
30-S-151
30-S-150
30-P-235
30-P-232
30-P-231
30-S-242
30-S-243
30-S-212
30-S-211
30-S-210
30-S-220
30-S-221
30-S-222
30-S-635
30-P-626
30-P-636
30-P-637
30-P-255
30-S-255
JB-S-151
JB-S-102
WD34-PITX-30106
30-S-261
30-S-260
30-P-260
30-P-251
30-S-251
30-P-250
30-S-116
30-P-635
30-P-625
30-P-601
30-P-602
30-P-120
30-S-120
30-S-258
30-S-253
30-P-253
30-S-257
30-S-121
30-S-206
30-P-206
30-P-021
30-P-022
30-P-023
30-P-020 30-P-615
30-S-170
30-P-616
30-S-202
30-S-205
30-S-209
30-S-204
30-P-202
30-P-610
30-P-611
30-P-630
30-P-160
30-S-245
30-S-225 30-P-236
30-S-238
30-S-158
30-P-254
30-P-256
30-P-252
30-P-161
WD05-FANX-30303
WD37-HXGR-30002
3 2
30-P-201 30-P-632
30-S-201
30-S-231
WD34-FCVX-30120
WD34-FITX-30105
WD37-HXGR-30401
30-S-215
TYP
(TYP) EM210
5 30-S-631
WD37-HSNX-30302
WD33-LITX-30201
5 5
WD33-LEXX-30201
30-S-176
30-S-177
30-S-178
WD33-VFDX-30401
WD33-VFDX-30402
WD34-LSHX-30209 30-P-631
KEY NOTES:
1. FUTURE WATER TREATMENT CONTROL PANEL.
2. DO NOT ROUTE CONDUIT THROUGH TRENCHES.
3. WIRE THE RESTROOM EXHAUST FAN TO THE RESTROOM
LIGHT SWITCH.
4. PROVIDE 2-POLE MANUAL MOTOR STARTERS FOR INDOOR
HVAC UNITS.
5. PROVIDE CONDUIT AND PULL STRING TO MANUFACTURER
THERMOSTAT.
#
GENERAL NOTES:
1. SEE DRAWING 13E01 FOR LOCATION OF FACILITY ON SITE
PLAN.
2. DO NOT ATTACH CONDUIT OR ELECTRICAL EQUIPMENT TO
THE ACOUSTICAL PANELS.
FACP
WD08-CKEY-30900
WD08-NVRX-30301
WD08-NVRX-30300
WD37-HVAC-30105
WD37-HVAC-30104
WD37-HVAC-30102
WD37-HVAC-30103
WD31-LPXX-30108
WD31-XFMR-30107
WD37-HEAT-30204
WD31-MCCX-30100
WD31-SWBD-30105 WD31-PLCP-30101
1 WD34-VFDX-30101
30-P-022
30-P-021
30-P-020
30-P-023
30-P-616
30-P-202
30-P-032
30-P-031
30-P-030
30-P-033
30-P-653
30-P-655
30-P-657
30-P-651
30-P-150
30-P-111 30-P-110
30-P-606
30-P-621
30-P-605
30-P-236
30-P-260
30-P-637
30-S-160
30-S-225
30-S-238
30-S-245
30-S-261
30-S-260
30-P-161
30-P-206
30-P-120
30-P-201
30-P-155 30-S-161
30-S-226
30-P-652
30-P-105
30-P-104
30-P-103
4 30-P-650
30-P-656
30-P-654
30-S-118
30-S-031
30-S-030
30-P-632
30-S-215
30-S-201
30-S-101
30-P-153
30-P-151
30-P-152
JB-S-104 30-P-154
30-S-121
30-P-602
30-S-158
30-S-227
30-S-162
5 1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/13/2024 11:36:58 AM
R:\d1341482\11843A1013E801.rvt
13E03
CAMPUS OAKS ASR WELL
EXPOSED POWER AND CONTROL PLAN 88
ELECTRICAL
EYV
CAC
SCALE:
PARTIAL PLAN
1/4" = 1'-0"
B
SCALE:
DETAIL
3/8" = 1'-0" 13E03
1 ELECTRICAL ROOM
13E01
T
T
35 d 3
37 c 3
41 a
3 34GFCI
J
J
J
J
J
J
34 GFCI
34 GFCI
36 GFCI
32 GFCI
32 GFCI
36 GFCI
36GFCI
40 GFCI
40 GFCI
40GFCI
40 GFCI
38GFCI
30WP-GFCI
30 WP-GFCI
30 WP-GFCI
30 WP-GFCI
35 d 3
37 3 c
39 b
41a
3 41
a 4
47 WP,GFCI
45 WP,GFCI
KEY NOTES:
1. GROUND THE FLOW METER.
2. COORDINATE THE HEIGHT OF THE FIXTURES OVER THE DOORS WITH THE ARCHITECTURAL DRAWINGS.
3. WIRE THE RESTROOM EXHAUST FAN TO THE RESTROOM LIGHT
SWITCH.
4. REFER TO SPECIFICATION SECTION 08710 FOR DEVICE DETAILS.
5. PROVISIONS FOR FUTURE CARD READER AND ELECTRIFIED
HARDWARE.
6. 20A SINGLE RECEPTACLES FOR MONITORING WELL PUMP VFDS.
7. LOCATE RESTROOM LIGHT SWITCH AS CLOSE AS POSSIBLE TO ENTRY DOOR.
#
GENERAL NOTES:
1. SEE DRAWING 13E01 FOR LOCATION OF FACILITY ON SITE PLAN.
2. ALL CIRCUIT DESIGNATIONS REFER TO PANELBOARD WD31-LPXX-30108.
3. BOND DUCT BANK GROUND CONDUCTORS TO THE GROUND RING.
WD08-CAMX-30307 WD09-ZSXH-30793
WD09-ZSXG-30793
WD09-ZSXA-30793
WD09-ZSXB-30793
WD09-ZSXC-30793
WD09-ZSXD-30793
WD08-CAMX-30302
WD08-CAMX-30304
WD08-CAMX-30303
WD08-CAMX-30306
WD09-ZSXE-30793
WD09-ZSXF-30793
WD08-CAMX-30305
WD31-XFMR-30107
WD31-LPXX-30108 WD31-MCCX-30100
WD31-SWBD-30105
WD31-PLCP-30101
TYP
EG051
TYP
EG052 (TYP)
TYP
EG151 (TYP)
TYP
EG204 (TYP)
TYP
EM171 (TYP) CONTINUED ON DWG 13E01
30G
13E05
30A
13E05
30C
30B 13E05
13E05
1 3
WD37-HVAC-30101
30I
13E05
30H
13E05
PB-E-1
PB-S-1
TYP
EL700 (TYP)
TYP
EL701
TYP
EL200 (TYP)
30-S-707
30-S-701
WD08-CAMX-30301
30-S-706
30-S-726
30-S-727 30-S-728 30-S-729
30-S-721
30-S-720
CARD READER
ELECTRIFIED
HARDWARE
4 JB-S-220
30-S-743
30-S-722
JB-S-240
WD08-NVRX-30300
WD08-NVRX-30301
WD08-CKEY-30900
30-S-713
30-S-704
30-S-702
5 30-E-742
30-E-741
30-E-743
JB-S-230
30-S-723
30-S-712
30-S-724
30-S-725
JB-S-210
5 30-E-752
30-S-738 30-E-751
30-S-736
30-S-730
30-S-705
JB-S-250
30-S-711
30-S-703
30-S-710
JB-S-200
30-S-742
30-S-741
30-S-737
A
c 37
10'-0"
A
c 37
10'-0"
A
c 37
10'-0"
B
c 39
9'-0"
A
c 37
10'-0"
B
c 37
10'-0"
A
c 37
10'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0"
B
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0" A
a 41
10'-0"
B
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0" A
a 41
10'-0" A
a 41
10'-0" A
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0"
D
29 7'-6"
D
29 9'-0"
D
29 9'-0"
C
33 0"
C
33 0"
D
31 9'-0"
C
33 0"
D
31 9'-0"
D
31 9'-0"
A
b 39
8'-0"
2 2
2 TYP
EG511 (TYP)
6 7 30-E-753
30-S-735
30-S-731
B
c 39
9'-0"
B
c 39
9'-0"
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/10/2024 1:20:43 PM
R:\d1341482\11843A1013E801.rvt
13E04
CAMPUS OAKS ASR WELL
LIGHTING AND GROUNDING PLAN 89
ELECTRICAL
EYV
CAC
SCALE:
ENLARGED PLAN
1/4" = 1'-0"
C
13E01
178
30-E-501 (2") 30-E-502 (2") 30-P-010 (3") 30-P-011 (3") 30-P-012 (3") 30-P-013 (3") 30-P-010 (3") 30-P-011 (3") 30-P-012 (3") 30-P-013 30-F-001 (3") (2") 30-F-001 (2") 30-E-503 (2") 30-E-504 (2") Width: 3'-1" Height: 1'-6" Width: 2'-8" Height: 1'-6" Width: 1'-2" Height: 1'-5" Width: 1'-7" Height: 1'-9" 30A DUCT BANK SECTION 30B DUCT BANK SECTION 30C DUCT BANK SECTION 30D DUCT BANK SECTION 13E02, 13E04 13E02, 13E04 13E02 30-E-510 (2") 30-E-511 (2") 30-E-520 (2") 30-E-522 (2") 30-E-524 (2") 30-E-526 (2") 30-E-501 (2") 30-E-502 (2") 30-E-503 (2") 30-E-504 (2") 30-E-510 (2") 30-E-511 (2") 30-E-512 (2") 30-E-513 (2") 30-E-520 (2") 30-E-521 (2") 30-E-510 (2") 30-E-511 (2") 30-E-501 (2") 30-E-502 (2") 30-E-503 (2") 30-E-504 (2") 30-E-512 (2") 30-E-513 (2") 30-E-521 (2") 30-E-523 (2") 30-E-525 (2") 30-E-527 (2") 30-E-520 (2") 30-E-521 (2") 30-E-522 (2") 30-E-523 (2") 30-E-524 (2") 30-E-525 (2") 30-E-526 (2") 30-E-527 (2") 30-E-522 (2") 30-E-523 (2") 30-E-524 (2") 30-E-525 (2") 30-E-526 (2") 30-E-527 (2") 30-E-512 (2") 30-E-513 (2") Width: 1'-7" Height: 1'-9" Width: 2'-4" Height: 1'-9" Width: 3'-10" Height: 1'-9" Width: 2'-4" Height: 1'-9" Width: 2'-4" Height: 1'-9" 30E DUCT BANK SECTION 30F DUCT BANK SECTION 30G DUCT BANK SECTION 30H DUCT BANK SECTION 30I DUCT BANK SECTION 13E02 13E02 13E02 13E02, 13E04 13E02, 13E04 UPDATE DATE: 11/20/2024 10:05: 13E01, 13E02 , 13E04 Plot Date: 12/10/2024 12:05:13 PM PROJECT NO.
LAST SAVED BY: FILE NAME: CAC EYV RM 13E05 90 ELECTRICAL CAMPUS OAKS ASR WELL DUCT BANK SECTIONS 11843A1013E05.dwgOWestbrook REV DATE BY DESCRIPTION 0 DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 No. 20740 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION # GENERAL NOTES: 1. CONSTRUCT DUCT BANK PER DETAIL EM001/TYP UNLESS OTHERWISE INDICATED. 178 20" 20"
90"
20" 20" 20" 25"
FRONT VIEW SIDE VIEW
FILE:SCALE:
FILE:SCALE:
11843A1003E601 11843A1003E601
1 A -
B -C -D -
E -F -G -H -I -J -K -
L -
2 3 4 5
3/4" = 1'-0" 3/4" = 1'-0"
1A-
(TOP FEED)MAIN LUGS 2A- WD31-PQMX-30104
POWER METER
3A- WD31-XFMR-30107
WD31-LPXX-30108LIGHTINGPANEL
4A- WD37-HEAT-30204
ELECTRICALROOM UNITHEATER
5A- SPACE
2EWD37-FANX-30301
PUMP ROOMEXHAUST FAN
3C- WD37-HVAC-30101
ELECTRICALROOM OUTDOORUNIT
4B- WD37-HXGR-30401
ESS TANKLESSWATER HEATER
5F- WD34-PUMP-30101
ASR PUMP
2HWD37-FANX-30302
CHEMICALROOM EXHAUSTFAN
3D- WD37-HEAT-30201
PUMP ROOMUNITHEATER NO. 1
4C- SPARE
2JSPACE 3E- WD37-HEAT-30202 PUMP ROOM UNIT HEATER NO. 2 4D- SPARE 3F- WD37-HEAT-30203
CHEMICALROOM UNITHEATER
4E- SPACE
3G- SPACE
SPD
2LREV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:03-DEC-20249:36:07AMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:11843A1013E06.dgn
63 13E06
CAC
BLS
ELECTRICAL
WD31-MCCX-30100 ELEVATION
CAMPUS OAKS ASR WELL
89 OWestbrook
91 178
# KEY NOTES:
ALLOWING FOR REMOTE OPEN, CLOSE AND RESET.
1. PROVIDE THE MAIN BREAKER WITH A MOTOR OPERATOR
INCLUDE MAINTENANCE MODE SETTINGS.
2. THE SOLID STATE CIRCUIT BREAKER TRIP UNITS SHALL
3 PHASE750 KVA12 KV480/277 V
4 5
6 GENERAL NOTES:
CONTINUEDATLOWERLEFT
CONTINUEDATUPPERRIGHT
3P
TM
45 KVA
65 KAIC
WD31-XFMR-30107
3-#1(Ø)&1-#6(G)
208/120 V480 V
WD31-LPXX-30108
3 PH
1 SSM
MAIN LUGS POWER METER
WD31-PQMX-30104
SPD
SS
1000 AT
SS
1000 AT
K K
SWITCHBOARD
METERING
ELECTRIC
ROSEVILLE
1 2 2
7 3
2 MAIN BREAKER
WD31-BKRX-30105
4 3
SPARE
TM
3P
20 AT 65 KAIC
SPARE
TM
3P
20 AT 65 KAIC
COMPARTMENTS.
2. REFER TO THE MCC ELEVATION DRAWING FOR REQUIRED SPACE CONFORM TO ROSEVILLE ELECTRIC STANDARDS.
1. ALL WORK ON THE INCOMING SERVICE SHALL
ELECTRIC.STANDARDS. THE TRANSFORMER IS PROVIDED BY ROSEVILLE
5. PROVIDE TRANSFORMER PAD PER ROSEVILLE ELECTRIC
SHOWN ON THE ELECTRICAL PLANS AND THE CONDUIT SCHEDULE
6. PROVIDE SECONDARY CONDUIT AND CONDUCTORS AS
PROVIDED BY ROSEVILLE ELECTRICELECTRICAL SITE PLAN. THE PRIMARY CONDUCTORS ARE ROSEVILLE ELECTRIC VAULT AT THE LOCATION SHOWN ON THE
4. PROVIDE A 4" CONDUIT FROM THE UTILITY TRANSFORMER TO THE 2 65 KAIC
1200 AF
65 KAIC
1200 AF
00E01
4{3-350KCMIL(Ø)&1-#3/0(G)}
WD31-MCCX-30100, 1200 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 00E02 00E02 00E01
PANEL
LIGHTING
125 AT
3-#1/0(Ø)&1-#1/0(N)&1-#6(G)
PROVIDED BY THE CONTRACTOR.ROSEVILLE ELECTRIC. THE METER SOCKET AND SWITCHBOARD ARE
7. THE INSTRUMENT TRANSFORMERS AND METER ARE PROVIDED BY
CABINET
CONNECTION
GENERATOR
3 PH480 V1200 A
B
WATER HEATER
ESS TANKLESS
WD37-HXGR-30401
72 KW
3-#2(Ø)&1-#6(G)
3-#2(Ø)&1-#6(G)
65 KAICTM
110 AT 3P
D
5 65 KAICTM
AMP
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
WD37-HEAT-30204
HEATER
ROOM UNIT
ELECTRICAL
A
8 65 KAICTM
AMP
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
WD37-HEAT-30203
20 AT 3P
20 AT 3P
HEATER
ROOM UNIT
CHEMICAL
E
65 KAICTM
AMP
WD37-HVAC-30101
35 AT 3P
3-#8(Ø)&1-#10(G)
3-#8(Ø)&1-#10(G)
25.9 C
65 KAICTM
AMP
WD37-HEAT-30201
20 AT 3P
3-#4(Ø)&1-#8(G)
3-#4(Ø)&1-#8(G)
5 OUTDOOR UNIT
ELECTRICAL ROOM
HEATER NO.1
PUMP ROOM
SPD
C
65 KAICTM
AMP
WD37-HEAT-30202
20 AT 3P
5 HEATER NO.2
PUMP ROOM
SIZE 1FVNR
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
A
1/4
WD37-FANX-30302
3 AC 3P
SIZE 1FVNR
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
65 KAICMCP
FAN
ROOM EXHAUST
CHEMICAL
00E02
C
450
WD37-FANX-30301
3 AC 3P
SIZE 1FVNR
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
65 KAICMCP
EXHAUST FAN
PUMP ROOM
65 KAICSS
800 AT 3P 800 AF
LR
VFD-RH/B
WD34-PUMP-30101
WD34-VFDX-30101
3{3-350KCMIL(Ø)&1-#2/0(G)}
1/4
BYPASS STARTER.
3. ACTIVE FRONT-END VFD WITH FULL VOLTAGE, NON-REVERSING
ASR PUMP
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:10-DEC-20241:37:42PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:11843A1013E07.dgn
13E07
CAC
BLS
ELECTRICAL
WD31-MCCX-30100 ONE-LINE DIAGRAM 92
CAMPUS OAKS ASR WELL
WD31-SWBD-30105
OWestbrook
RM
178
ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE 11/21/2024 TAG NO MINIMUM INTERIOR DIMENSIONS (INCHES) CONSTRUCTION TYPICAL DETAIL SURFACE LOADING COMMENTS WIDTH LENGTH DEPTH PANEL WD31-LPXX-30108 12/1/2024 LOCATION: CAMPUS OAKS NEMA: 1 PH A WEIGHTED VA 10358 VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 11168 PHASE & WIRE:3 PH 4W MTG. SURFACE PH C WEIGHTED VA 10955 INTERRUPT: 10 KAIC BUS RATING: 150 OPTIONS: SPD MAIN: CB EQUIP SIZING VA 33503 MAIN RATING: 150 AF 150 AT PANEL AMPS 93.0 I/C/S DESCRIPTION LOAD (VA) BKR CIR Ø CIR BKR LOAD (VA) DESCRIPTION I/C/S S WD31-PLCP-30101 - PLC AUX POWER 350 15A-1P 1 A 2 15A-2P 150 WD37-HVAC-30102 - ELECTRICAL ROOM INDOOR UNIT 1 C C WD31-PLCP-30101 - PLC UPS POWER 1000 15A-1P 3 B 4 150 C C WD37-HXGR-30002 - RESTROOM WATER HEATER 2050 25A-2P 5 C 6 15A-2P 150 WD37-HVAC-30103 - ELECTRICAL ROOM INDOOR UNIT 2 C C 2050 7 A 8 150 C C WD05-FANX-30303 - RESTROOM LIGHT AND EXHAUST FAN 160 15A-1P 9 B 10 15A-2P 150 WD37-HVAC-30104 - ELECTRICAL ROOM INDOOR UNIT 3 C C WD08-HMIX-30103 - OPERATOR INTERFACE 500 15A-1P 11 C 12 150 C C WD08-NVRX-30300 - VIDEO RECORDER 500 15A-1P 13 A 14 15A-2P 150 WD37-HVAC-30105 - ELECTRICAL ROOM INDOOR UNIT 4 C C WD08-NVRX-30301 - VIDEO RECORDER 500 15A-1P 15 B 16 150 C C WD08-CKEY-30900 - CARD READER PANEL 500 15A-1P 17 C 18 15A-1P 1676 WD33-LCPX-30310 - SODIUM FLUORIDE I I GATE OPERATOR 3000 35A-1P 19 A 20 15A-1P 1176 WD34-FCVX-30120 - WELL ANNULUS RECHARGE VALVE I I WD33-PLCP-30210 - HYPOCHLORITE VCP 2852 30A-1P 21 B 22 15A-1P 1176 WD34-FCVX-30150 - RECHARGE CONTROL VALVE I I WD34-MOVX-30130 - PUMP COLUMN RECHARGE CONTROL VALVE 1176 15A-1P 23 C 24 20A-1P SPARE I WD34-MOVX-30140 - AQUIFER & WELL FLUSH TO WASTE VALVE 1176 15A-1P 25 A 26 20A-1P 400 FACP C I WD34-MOVX-30160 - RECOVERY/PRODUCTION VALVE 1176 15A-1P 27 B 28 20A-1P SPARE C EXIT LIGHTS 27 20A-1P 29 C 30 20A-1P 720 EXTERIOR RECEPTACLES I C EXIT LIGHTS 27 20A-1P 31 A 32 20A-1P 360 CHEMICAL ROOM RECEPTACLES I C EXTERIOR LIGHTS 117 20A-1P 33 B 34 20A-1P 540 ELECTRICAL ROOM RECEPTACLES I I ELECTRICAL ROOM LIGHTS 182 20A-1P 35 C 36 20A-1P 540 CHEMICAL ROOM RECEPTACLES I I CHEMICAL ROOM LIGHTS 182 20A-1P 37 A 38 20A-1P 180 RESTROOM RECEPTACLE I SPARE 20A-1P 39 B 40 20A-1P 720 PUMP ROOM RECEPTACLES I C PUMP ROOM LIGHTS 416 20A-1P 41 C 42 25A-1P 1920 MONITORING WELL RECEPTACLE S SPARE 20A-1P 43 A 44 25A-1P 1920 MONITORING WELL RECEPTACLE S I WD33-PUMP-30401 - MONITORING WELL PUMP 1 1920 25A-1P 45 B 46 20A-1P SPARE I WD33-PUMP-30402 - MONITORING WELL PUMP 2 1920 25A-1P 47 C 48 20A-1P SPARE SPARE 20A-1P 49 A 50 20A-1P SPARE SPARE 20A-1P 51 B 52 20A-1P SPARE SPARE 20A-1P 53 C 54 20A-1P SPARE Plot Date: 12/1/2024 6:41:11 PM PROJECT NO.
LAST SAVED BY: FILE NAME: CAC EYV 13E08 91 ELECTRICAL CAMPUS OAKS ASR WELL PANELBOARD & HANDHOLE/MANHOLE SCHEDULES 11843A1013E08.dwgOWestbrook REV DATE BY DESCRIPTION 0 DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 175 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 DRAFT FINAL SUBMITTAL No. 20740 93 178 J ELEC. PB
P L E A S A N T
G R O V E
B L V D .
Plot Date: 12/10/2024 12:19:20 PM REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 No. 20740 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION WELL BUILDING 0 10' 20' 40' SCALE: 1" = 20' SEE A / 19E02 SEE B / 19E03 SEE C / 19E04 UTILITY TRANSFORMER FIBER OPTIC HANDHOLE PB-E-2 PB-S-2 36A 13E05 FIRE STROBE GATE CARD READER KNOX BOX 36-S-760 36-S-761 36-S-751 36-P-401 36-S-752 36-S-765 TYP EM015 TYP EM015 GATE OPERATOR 36-E-762 36-P-175 36-S-175 TYP EM015 TYP EL506 1 PB-S-3 44WP,GFCI 46WP,GFCI 2 # KEY NOTES: 1. PROVIDE 12' ALUMINUM ROUND STRAIGHT POLE FOR LICENSE PLATE READER CAMERAS. CAMERAS PROVIDED BY OTHERS. 2. 20A SINGLE RECEPTACLE. MONITORING WELL JB-S-340 TYP EM052 TYP EM315 36-E-761 PROJECT NO.
LAST SAVED BY: FILE NAME: CAC TLMRM 19E01 94 ELECTRICAL MISTY WOOD ASR WELL ELECTRICAL SITE PLAN 11843A1019E01.dwgOWestbrook 1780
T
T
S S
CC
C
KEY NOTES:
1. FUTURE WATER TREATMENT CONTROL PANEL.
2. CORE DRILL CONDUIT PENETRATION IN WET WELL AND FILL WITH NON-SHRINK EPOXY GROUT. ROUTE SUBMERSIBLE PUMP CABLES IN CONDUIT TO VCP AND TERMINATE. PROVIDE STRAIN RELIEF IN WET WELL WHERE SUBMERSIBLE CABLE ENTERS CONDUIT.
#
GENERAL NOTES:
1. SEE DRAWING 19E01 FOR LOCATION OF FACILITY ON SITE PLAN.
WD31-XFMR-36107
WD31-LPXX-36108
FACP
WD08-CKEY-36900
WD08-NVRX-36301
TYP
EM118
1 WD31-PLCP-36101
WD37-HVAC-36101
WD31-MCCX-36100
WD31-SWBD-36105
PB-E-2
PB-S-2
36I
36H 19E05
19E05
CONTINUED ON
DWG 19E01
36F
19E05
36E
19E05
36D
19E05
36C
19E05 36B
19E05
36A
19E05
36G
19E05
WD34-VFDX-36101
TYP
EM001 (TYP)
TYP
EM001 (TYP)
WD31-MCCX-36100
36-P-176 36-P-177
WD33-VFDX-36401 WD33-VFDX-36402
36-P-102
36-P-101
36-E-503
36-E-504
36-E-501
36-E-502
36-E-520
36-E-521
36-E-522
36-E-523
36-E-520
36-E-521
36-E-522
36-E-523
36-E-510
36-P-013
36-P-012
36-P-011
36-P-010
36-E-511
36-E-512
36-E-513
36-F-001
WD08-NVRX-36300
36-S-175
36-E-761
CONTINUED ON
DWG 19E01
CONTINUED ON
DWG 19E01
CONTINUED ON
DWG 19E01
36-E-524
36-E-525
36-E-526
36-E-527
WD37-XFMR-36901
WD37-VCPX-36901
36-E-411
TYP
EM015
2 36-P-175 36-P-401
36-S-752
GRINDER PUMP STATION
36-S-751
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/10/2024 1:23:01 PM
R:\d1341482\11843A1019E801.rvt
19E02
MISTY WOOD ASR WELL
UNDERGROUND POWER AND CONTROL PLAN 95
ELECTRICAL
TLM
CAC
SCALE:
PLAN A 1/4" = 1'-0"
178
T
T
D
S S
CC
SSS
C
T
B
E
A
A
J
J
J
J
J
J
J
T
D
J
WD34-FCVX-36120
WD34-PITX-36102
WD34-PDIT-36151
1 19E03
30-S-237
30-S-233
30-S-236
30-S-230
30-S-229
30-S-156
30-P-234
30-S-160
30-S-154
30-S-153
30-S-157
30-S-152
30-S-151
30-S-150
30-P-235
30-P-232
30-S-242
30-S-243
30-S-212
30-S-211
30-S-210
30-S-221
30-S-222
30-S-635
30-P-636
30-P-637
30-P-255
30-S-255
30-S-261
30-S-260
30-P-260
30-P-251
30-S-251
30-P-250
30-S-116
30-P-120
30-S-120
30-S-258
30-S-253
30-P-253
30-S-257
30-P-021
30-P-022
30-P-023
30-P-020
30-S-202
30-S-205
30-S-209
30-S-204
30-S-245
30-S-225 30-P-236
30-S-238
30-S-158
30-P-256
30-P-161
30-P-201
30-S-201
30-S-231
30-S-215
30-S-631
36-S-237
36-S-233
36-S-236
36-S-230
36-S-229
36-S-156
36-P-234
36-S-160
36-S-154
36-S-153
36-S-157
36-S-152
36-S-151
36-S-150
36-P-235
36-P-232
36-S-242
36-S-243
36-S-212
36-S-211
36-S-210
36-S-221
36-S-222
36-S-635
36-P-636
36-P-637
36-P-255
36-S-255
36-S-261
36-S-260
36-P-260
36-P-251
36-S-251
36-P-250
36-S-116
36-P-120
36-S-120
36-S-258
36-S-253
36-P-253
36-S-257
36-P-021
36-P-022
36-P-023
36-P-020
36-S-170
36-P-616 36-S-202
36-S-205
36-S-209
36-S-204
36-S-245
36-S-225 36-P-236
36-S-238
36-S-158
36-P-256
36-P-161
36-P-201
36-S-201
36-S-231
36-S-215
36-S-631
36-P-620
36-P-621
36-P-231
36-S-220
36-P-626
36-P-635
36-P-625
36-P-601
36-P-602
36-S-121
36-S-206
36-P-206
36-P-615
36-P-202
36-P-610
36-P-611
36-P-630
36-P-160
36-P-254
36-P-252
36-P-632
WD34-PITX-36109
WD34-PUMP-36101
WD34-MOVX-36130
WD34-VCPX-36121
WD33-PLCP-36210
JB-S-303
WD34-TANK-36305
JB-S-353
JB-S-300
WD37-HEAT-36201
JB-S-350
WD34-FSLX-36113
WD34-SOVX-36101
JB-S-351
JB-S-302
WD05-FANX-36303
WD34-FITX-36105
WD37-HVAC-36101
WD34-LCPX-36101
WD34-MOVX-36140
WD34-FCVX-36150
WD34-MOVX-36160 WD33-LCPX-36310
WD37-FSHX-36001
WD37-HEAT-36202
WD37-HEAT-36203
WD37-FANX-36302
JB-S-352
WD33-AITX-36205
WD37-FANX-36301
WD33-AITX-36206
WD33-AITX-36307
WD37-TSHX-36301
WD33-LCPX-36202
WD37-HXGR-36002
WD33-LEXX-36201
2 5
5 5
WD37-HSNX-36302
WD33-LITX-36201
WD34-PSHH-36107
WD34-FITX-36104
3 WD08-HMIX-36103
GENERATOR CONNECTION CABINET
WD37-HXGR-36401
WD34-LSHX-36209
WD34-LITX-36100
WD37-VCPX-36901
36-P-412
WD37-XFMR-36901
36-S-411
36-P-121 WD34-PITX-36106
36-P-411
36-P-631
36-S-176
36-S-177
36-S-178
WD33-VFDX-36401
WD33-VFDX-36402
KEY NOTES:
1. FUTURE WATER TREATMENT CONTROL PANEL.
#
GENERAL NOTES:
1. SEE DRAWING 19E01 FOR LOCATION OF FACILITY ON SITE PLAN.
2. DO NOT ATTACH CONDUIT OR ELECTRICAL EQUIPMENT TO THE ACOUSTICAL PANELS.
2. DO NOT ROUTE CONDUIT THROUGH TRENCHES.
3. WIRE THE RESTROOM EXHAUST FAN TO THE RESTROOM LIGHT
SWITCH.
4. PROVIDE 2-POLE MANUAL MOTOR STARTERS FOR INDOOR HVAC UNITS.
5. PROVIDE CONDUIT AND PULL STRING TO MANUFACTURER
THERMOSTAT.
36-P-150
36-P-110 36-P-111
36-P-606
36-P-621
36-P-605
36-S-226
36-P-650
36-P-022
36-P-021
36-P-020
36-P-023
36-P-616
36-P-202
36-P-032
36-P-031
36-P-030
36-P-033
36-P-653
36-P-655
36-P-657
36-P-651
36-P-236
36-P-260
36-P-637
36-S-160
36-S-225
36-S-238
36-S-245
36-S-261
36-S-260
36-P-161
36-P-206
36-P-121
36-P-201
36-P-155 36-S-161
36-P-652
36-P-105
36-P-104
36-P-103
36-P-656
36-P-654
36-S-118
36-S-031
36-S-030
36-P-632
36-S-215
36-S-201
36-S-101
36-P-153
36-P-151
36-P-152
36-P-154
36-S-121
36-P-602
36-S-158
36-S-227
36-S-162
WD31-LPXX-36108
WD31-XFMR-36107
WD37-HEAT-36204
WD31-MCCX-36100
WD34-VFDX-36101
JB-S-304 FACP
WD08-CKEY-36900
WD08-NVRX-36301
WD31-SWBD-36105 WD31-PLCP-36101
4 WD08-NVRX-36300
WD37-HVAC-36102 WD37-HVAC-36103
WD37-HVAC-36104
WD37-HVAC-36105
1 1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/11/2024 11:32:04 AM
R:\d1341482\11843A1019E801.rvt
19E03
MISTY WOOD ASR WELL
EXPOSED POWER AND CONTROL PLAN 96
ELECTRICAL
EYV
CAC
SCALE:
PARTIAL PLAN
1/4" = 1'-0"
B
SCALE:
DETAIL
19E03 3/8" = 1'-0"
1 19E01
T
T
35 d 3
35 d 3
37 3 c
37 c 3
41 a
3 39
b
41a
3 41
a 4
34 GFCI
34 GFCI
34GFCI
36 GFCI
32 GFCI
32 GFCI
36 GFCI
36GFCI
40 GFCI
40 GFCI
40GFCI
38GFCI
30WP-GFCI
30 WP-GFCI 30
WP-GFCI
30 WP-GFCI
40 GFCI
J
J
J
J
J
J
WD31-XFMR-36107
WD34-VFDX-36101
WD31-SWBD-36105
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
A
d 35
9'-0"
D
29 9'-0"
D
29 9'-0"
C
33 0"
A
c 37
10'-0"
A
c 37
10'-0"
A
c 37
10'-0"
B
c 37
10'-0"
A
c 37
10'-0"
B
c 37
10'-0"
A
c 37
10'-0"
D
31 9'-0"
C
33 0"
A
a 41
10'-0" A
a 41
10'-0"
B
a 41
10'-0" A
a 41
10'-0"
B
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0"
A
a 41
10'-0" A
a 41
10'-0" A
a 41
10'-0" A
a 41
10'-0"
A
a 41
10'-0" A
a 41
10'-0" A
a 41
10'-0" A
a 41
10'-0"
TYP
EG051
TYP
EG052 (TYP)
TYP
EG151 (TYP)
D
31 9'-0"
D
31 9'-0"
D
29 8'-0"
A
b 39
8'-0"
TYP
EG204 (TYP)
TYP
(TYP) EG511
TYP
EM171 (TYP)
TYP
EL200 (TYP)
C
33 0"
3 2
1 2
2 36I
19E05
36H
19E05
CONTINUED ON
DWG 19E01
36C
19E05 36B
19E05
36A
19E05
WD31-PLCP-36101
TYP
EL701
TYP
EL700 (TYP)
WD08-CAMX-36307
WD09-ZSXG-36793
WD09-ZSXA-36793
WD08-CAMX-36303
WD08-CAMX-36306
WD31-LPXX-36108 WD31-MCCX-36100
WD31-PLCP-36101
WD08-CAMX-36301
JB-S-420
WD08-NVRX-36300
WD08-NVRX-36301
WD08-CKEY-36900
JB-S-400
WD09-ZSXH-36793
WD09-ZSXB-36793
WD09-ZSXC-36793
WD09-ZSXD-36793
WD08-CAMX-36302
WD08-CAMX-36304
WD09-ZSXE-36793
WD09-ZSXF-36793
WD08-CAMX-36305
WD37-HVAC-36101
JB-S-440
JB-S-430
JB-S-410
JB-S-450
36-S-707
36-S-701
36-S-706
36-S-726
36-S-727 36-S-728
36-S-743
36-S-713
36-S-704
36-E-743
36-S-723
36-S-712
36-S-724
36-S-725
36-S-705
36-S-711
36-S-703
36-S-710
36-S-737
36-S-731
36-S-729
36-S-721
36-S-720
36-S-722
36-S-702
36-E-742
36-E-741
36-E-752
36-S-738 36-E-751
36-S-736
36-S-730
36-E-753
36-S-735
PB-E-1
PB-S-1
CARD READER
ELECTRIFIED
HARDWARE
36-S-742
36-S-741
5 TYP
EL700 (TYP) 5
GENERAL NOTES:
1. SEE DRAWING 19E01 FOR LOCATION OF FACILITY ON SITE PLAN.
2. ALL CIRCUIT DESIGNATIONS REFER TO PANELBOARD WD31-LPXX-36108.
KEY NOTES:
1. GROUND THE FLOW METER.
2. COORDINATE THE HEIGHT OF THE FIXTURES OVER THE DOORS WITH THE ARCHITECTURAL DRAWINGS.
3. WIRE THE RESTROOM EXHAUST FAN TO THE RESTROOM LIGHT
SWITCH.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED JOB NO.
DRAWING NO.
SHEET NO.
VERIFY SCALES
IF NOT ONE INCH ON
THIS SHEET, ADJUST
SCALES ACCORDINGLY
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
FILE NAME:
178
PLOT DATE:
DRAFT FINAL SUBMITTAL
NOT FOR CONSTRUCTION
DECEMBER 2024
CITY OF ROSEVILLE
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
11843A.10
12/9/2024 10:55:06 AM
R:\d1341482\11843A1019E801.rvt
19E04
MISTY WOOD ASR WELL
LIGHTING AND GROUNDING PLAN 97
ELECTRICAL
EYV
CAC
SCALE:
PLAN C 1/4" = 1'-0"
178
36-E-501 (2") 36-E-502 (2") 36-P-010 (3") 36-P-011 (3") 36-P-012 (3") 36-P-013 (3") 36-P-010 (3") 36-P-011 (3") 36-P-012 (3") 36-P-013 36-F-001 (3") (2") 36-F-001 (2") 36-E-503 (2") 36-E-504 (2") Width: 3'-1" Height: 1'-6" Width: 2'-8" Height: 1'-6" Width: 1'-2" Height: 1'-5" Width: 1'-7" Height: 1'-9" 36A DUCT BANK SECTION 36B DUCT BANK SECTION 36C DUCT BANK SECTION 36D DUCT BANK SECTION 19E01, 19E02, 19E04 19E02, 19E04 19E02, 19E04 19E02 36-E-510 (2") 36-E-511 (2") 36-E-520 (2") 36-E-522 (2") 36-E-524 (2") 36-E-526 (2") 36-E-501 (2") 36-E-502 (2") 36-E-503 (2") 36-E-504 (2") 36-E-510 (2") 36-E-511 (2") 36-E-512 (2") 36-E-513 (2") 36-E-520 (2") 36-E-521 (2") 36-E-510 (2") 36-E-511 (2") 36-E-501 (2") 36-E-502 (2") 36-E-503 (2") 36-E-504 (2") 36-E-512 (2") 36-E-513 (2") 36-E-521 (2") 36-E-523 (2") 36-E-525 (2") 36-E-527 (2") 36-E-520 (2") 36-E-521 (2") 36-E-522 (2") 36-E-523 (2") 36-E-524 (2") 36-E-525 (2") 36-E-526 (2") 36-E-527 (2") 36-E-522 (2") 36-E-523 (2") 36-E-524 (2") 36-E-525 (2") 36-E-526 (2") 36-E-527 (2") 36-E-512 (2") 36-E-513 (2") Width: 1'-7" Height: 1'-9" Width: 2'-4" Height: 1'-9" Width: 3'-10" Height: 1'-9" Width: 2'-4" Height: 1'-9" Width: 2'-4" Height: 1'-9" 36E DUCT BANK SECTION 36F DUCT BANK SECTION 36G DUCT BANK SECTION 36H DUCT BANK SECTION 36I DUCT BANK SECTION 19E02 19E02 19E02 19E02, 19E04 19E02, 19E04 Plot Date: 12/10/2024 12:07:13 PM REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 No. 20740 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION # GENERAL NOTES: 1. CONSTRUCT DUCT BANK PER DETAIL EM001/TYP UNLESS OTHERWISE INDICATED. PROJECT NO.
LAST SAVED BY: FILE NAME: CAC EYV RM 19E05 98 ELECTRICAL MISTY WOOD ASR WELL DUCT BANK SECTIONS 11843A1019E05.dwgOWestbrook 178
SCALE: FRONT VIEW 3/4" = 1'-0" SCALE: SIDE VIEW 3/4" = 1'-0" A - B - C - D - E - F - G - H - J - K - L - M - 20" 90" # 20" # 20" # 20" # 20" # 20"
90" SSM 1A- MAIN LUGS (TOP FEED) 2A- WD31-PQMX-
36104 POWER METER 3A- WD31-XFMR-
36107 WD31-LPXX-
36108 LIGHTING PANEL 4A- WD37-HEAT-
36204 ELECTRICAL ROOM UNIT HEATER 5A- SPACE 2E- SPD 3C- WD37-HVAC- 36101 ELECTRICAL ROOM OUTDOOR UNIT 4B- WD37-HXGR-
36401 ESS TANKLESS WATER HEATER 5F- WD34-PUMP-
36101 ASR PUMP 2H- WD37-FANX-
36301 PUMP ROOM EXHAUST FAN 3D- WD37-HEAT-
36201 PUMP ROOM UNIT HEATER NO. 1 4C- SPARE 2J- WD37-FANX- 36302 CHEMICAL ROOM EXHAUST FAN 3E- WD37-HEAT-
36202 PUMP ROOM UNIT HEATER NO. 2 4D- SPARE 2L- SPACE 3F- WD37-HEAT-36203 CHEMICAL ROOM UNIT HEATER 4E- SPACE 3G- SPACE Plot Date: 12/13/2024 12:18:11 PM FILE NAME: 11843A1019E06.DWG LAST SAVED BY: express tools user No. 20740 REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION PROJECT NO.
LAST SAVED BY: FILE NAME: CECERM 19E06 99 ELECTRICAL MISTY WOOD ASR WELL WD31-MCCX-36100 ELEVATION 11843A1019E06.dwgavates 1780
# KEY NOTES:
ALLOWING FOR REMOTE OPEN, CLOSE AND RESET.
1. PROVIDE THE MAIN BREAKER WITH A MOTOR OPERATOR
INCLUDE MAINTENANCE MODE SETTINGS.
2. THE SOLID STATE CIRCUIT BREAKER TRIP UNITS SHALL
3 PHASE750 KVA12 KV480/277 V
4 5
6 GENERAL NOTES:
CONTINUEDATLOWERLEFT
CONTINUEDATUPPERRIGHT
3P
TM
45 KVA
65 KAIC
WD31-XFMR-36107
3-#1(Ø)&1-#6(G)
208/120 V480 V
WD31-LPXX-36108
3 PH
3P
TM
A
HEATER
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
20 AT 65 KAIC
CHEMICAL
ROOM UNIT
WD37-HEAT-36203
AMP
8 3P
TM
E
35 AT 65 KAIC
OUTDOOR UNIT
WD37-HVAC-36101
AMP
3P
TM
C
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
20 AT 65 KAIC
PUMP ROOM
HEATER NO. 1
WD37-HEAT-36201
AMP
5 3P
TM
C
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
20 AT 65 KAIC
PUMP ROOM
HEATER NO. 2
WD37-HEAT-36202
AMP
5 3P
MCP
FVNR
A
1/4
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
65 KAIC
SIZE 1
3 AC
CHEMICAL
FAN
ROOM EXHAUST
WD37-FANX-36302
3P
MCP
FVNR
C
1/4
3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
65 KAIC
SIZE 1
3 AC
PUMP ROOM
EXHAUST FAN
WD37-FANX-36301
1 SSM
MAIN LUGS POWER METER
WD31-PQMX-36104
SPD
SS
900 AT
SS
900 AT
K K
SWITCHBOARD
METERING
ELECTRIC
ROSEVILLE
1 2 2
7 3
2 MAIN BREAKER
WD31-BKRX-36105
25.9 4 3
SPARE
TM
3P
20 AT 65 KAIC
SPARE
TM
3P
20 AT 65 KAIC
COMPARTMENTS.
2. REFER TO THE MCC ELEVATION DRAWING FOR REQUIRED SPACE CONFORM TO ROSEVILLE ELECTRIC STANDARDS.
1. ALL WORK ON THE INCOMING SERVICE SHALL
ELECTRIC.STANDARDS. THE TRANSFORMER IS PROVIDED BY ROSEVILLE
5. PROVIDE TRANSFORMER PAD PER ROSEVILLE ELECTRIC
SHOWN ON THE ELECTRICAL PLANS AND THE CONDUIT SCHEDULE
6. PROVIDE SECONDARY CONDUIT AND CONDUCTORS AS
PROVIDED BY ROSEVILLE ELECTRICELECTRICAL SITE PLAN. THE PRIMARY CONDUCTORS ARE ROSEVILLE ELECTRIC VAULT AT THE LOCATION SHOWN ON THE
4. PROVIDE A 4" CONDUIT FROM THE UTILITY TRANSFORMER TO THE 2 65 KAIC
1200 AF
65 KAIC
1200 AF
9 3-#8(Ø)&1-#10(G)
ELECTRICAL ROOM
SECONDARY CONDUCTORS.
9. REFER TO THE CONDUIT SCHEDULE FOR TRANSFORMER 8. NOT USED.
PROVIDED BY THE CONTRACTOR.ROSEVILLE ELECTRIC. THE METER SOCKET AND SWITCHBOARD ARE
7. THE INSTRUMENT TRANSFORMERS AND METER ARE PROVIDED BY 00E01
4{3-350KCMIL(Ø)&1-#3/0(G)}
WD31-MCCX-19100, 1200 AMPS, 480 VOLTS, 3 (Ø), 3 WIRE, 60 HZ, 65 KASC RMS 3-#8(Ø)&1-#10(G)
PANEL
LIGHTING
00E01
00E02 00E02
125 AT
3-#1/0(Ø)&1-#1/0(N)&1-#6(G)
CABINET
CONNECTION
GENERATOR
BYPASS STARTER.
3. ACTIVE FRONT-END VFD WITH FULL VOLTAGE, NON-REVERSING LR
450
WD34-VFDX-36101WD34-PUMP-36101
ASR PUMP
3PH
480V
1200 A
3P
TM
B
65 KAIC
WD37-HXGR-36401
KW
ESS TANKLESS
WATER HEATER
72 3-#2(Ø)&1-#6(G)
3-#2(Ø)&1-#6(G)
110 AT
3P
TM
D
65 KAIC
WD37-HEAT-36204
AMP
5 3-#12(Ø)&1-#12(G)
3-#12(Ø)&1-#12(G)
20 AT
ELECTRICAL
ROOM UNIT
HEATER
SPD
VFD-RH/B
SS
3P
65 KAIC
800 AF
800 AT
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
176
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20740
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:05-DEC-202410:55:32PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 19E07
LASTSAVEDBY:
PROJECT NO. FILE NAME:
CAC
BLS
ELECTRICAL
11843A1019E07.dgn
WD31-MCCX-36100 ONE-LINE DIAGRAM 98
WD31-SWBD-36105
MISTY WOOD ASR WELL
OWestbrook
100 178
ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE TAG NO MINIMUM INTERIOR DIMENSIONS (INCHES) CONSTRUCTION TYPICAL DETAIL SURFACE LOADING COMMENTS WIDTH LENGTH DEPTH PANEL WD31-LPXX-36108 12/13/2024 LOCATION: MISTY WOOD NEMA: 1 PH A WEIGHTED VA 11778 VOLTS: 208/120 FEED: BOTTOM PH B WEIGHTED VA 13088 PHASE & WIRE:3 PH 4W MTG. SURFACE PH C WEIGHTED VA 11455 INTERRUPT: 10 KAIC BUS RATING: 150 OPTIONS: SPD MAIN: CB EQUIP SIZING VA 39263 MAIN RATING: 150 AF 150 AT PANEL AMPS 109.0 I/C/S DESCRIPTION LOAD (VA) BKR CIR Ø CIR BKR LOAD (VA) DESCRIPTION I/C/S S WD31-PLCP-36101 - PLC AUX POWER 350 15A-1P 1 A 2 15A-2P 150 WD37-HVAC-36102 - ELECTRICAL ROOM INDOOR UNIT 1 C C WD31-PLCP-36101 - PLC UPS POWER 1000 15A-1P 3 B 4 150 C C WD37-HXGR-36002 - RESTROOM WATER HEATER 2050 25A-2P 5 C 6 15A-2P 150 WD37-HVAC-36103 - ELECTRICAL ROOM INDOOR UNIT 2 C C 2050 7 A 8 150 C C WD05-FANX-36303 - RESTROOM LIGHT AND EXHAUST FAN 160 15A-1P 9 B 10 15A-2P 150 WD37-HVAC-36104 - ELECTRICAL ROOM INDOOR UNIT 3 C C WD08-HMIX-36103 - OPERATOR INTERFACE 500 15A-1P 11 C 12 150 C C WD08-NVRX-36300 - VIDEO RECORDER 500 15A-1P 13 A 14 15A-2P 150 WD37-HVAC-36105 - ELECTRICAL ROOM INDOOR UNIT 4 C C WD08-NVRX-36301 - VIDEO RECORDER 500 15A-1P 15 B 16 150 C C WD08-CKEY-36900 - CARD READER PANEL 500 15A-1P 17 C 18 15A-1P 1676 WD33-LCPX-36310 - SODIUM FLUORIDE I I GATE OPERATOR 3000 35A-1P 19 A 20 15A-1P 1176 WD34-FCVX-36120 - WELL ANNULUS RECHARGE VALVE I I WD33-PLCP-36210 - HYPOCHLORITE VCP 2852 30A-1P 21 B 22 15A-1P 1176 WD34-FCVX-36150 - RECHARGE CONTROL VALVE I I WD34-MOVX-36130 - PUMP COLUMN RECHARGE CONTROL VALVE 1176 15A-1P 23 C 24 20A-1P SPARE I WD34-MOVX-36140 - AQUIFER & WELL FLUSH TO WASTE VALVE 1176 15A-1P 25 A 26 20A-2P 1920 WD37-XFMR-36901 - GRINDER PUMP CONTROL PANEL I I WD34-MOVX-36160 - RECOVERY/PRODUCTION VALVE 1176 15A-1P 27 B 28 1920 I C EXIT LIGHTS 27 20A-1P 29 C 30 20A-1P 720 EXTERIOR RECEPTACLES I C EXIT LIGHTS 27 20A-1P 31 A 32 20A-1P 360 CHEMICAL ROOM RECEPTACLES I C EXTERIOR LIGHTS 117 20A-1P 33 B 34 20A-1P 540 ELECTRICAL ROOM RECEPTACLES I I ELECTRICAL ROOM LIGHTS 182 20A-1P 35 C 36 20A-1P 540 CHEMICAL ROOM RECEPTACLES I I CHEMICAL ROOM LIGHTS 182 20A-1P 37 A 38 20A-1P 180 RESTROOM RECEPTACLE I SPARE 20A-1P 39 B 40 20A-1P 720 PUMP ROOM RECEPTACLES I C PUMP ROOM LIGHTS 416 20A-1P 41 C 42 20A-1P 400 FACP C SPARE 20A-1P 43 A 44 25A-1P 1920 MONITORING WELL RECEPTACLE S I WD33-PUMP-36401 - MONITORING WELL PUMP 1 1920 25A-1P 45 B 46 25A-1P 1920 MONITORING WELL RECEPTACLE S I WD33-PUMP-36402 - MONITORING WELL PUMP 2 1920 25A-1P 47 C 48 20A-1P SPARE SPARE 20A-1P 49 A 50 20A-1P SPARE SPARE 20A-1P 51 B 52 20A-1P SPARE SPARE 20A-1P 53 C 54 20A-1P SPARE Plot Date: 12/13/2024 12:25:11 PM FILE NAME: 11843A1019E08.DWG LAST SAVED BY: express tools user No. 20740 REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION PROJECT NO.
LAST SAVED BY: FILE NAME: CECERM 19E08 101 ELECTRICAL PANELBOARD AND HANDHOLE/ MANHOLE SCHEDULES 11843A1019E08.dwgOWestbrook 1780
DRAWING VISIBLE
FIELDS
FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4 FIELD - 5
REFER REFER
POINT
REFERREFERREFER
OPERATOR INTERFACE
REFER
POWER DEVICEPRIMARY FUNCTION
OPERATOR ACCESSIBLE
CB - DISC - DISCONNECT
FU - FUSE
POWER DEVICE
AUXILIARY FUNCTION FOR
OPERATOR ACCESSIBLE
DEVICESPOWER DEVICEPRIMARY FUNCTION
OPERATOR
INACCESSIBLE
CB - FU - FUSE
INSTRUMENT
PRIMARY ELEMENT
INSTRUMENT/CONTROL ELEMENT
PRIMARY FUNCTION
OPERATOR ACCESSIBLE
INSTRUMENT/CONTROL ELEMENT
AUXILIARY FUNCTION
OPERATOR ACCESSIBLE
INSTRUMENT/CONTROL ELEMENT
PRIMARY FUNCTION
OPERATOR INACCESSIBLE
INSTRUMENT/CONTROL ELEMENT
AUXILIARY FUNCTION
OPERATOR INACCESSIBLE
FIELD EQUIPMENT
NON-POWERED
REFER
FIELD EQUIPMENT
PRIMARY FUNCTIONPOWERED
REFER
FIELD EQUIPMENT
AUXILIARY FUNCTION
POWERED
REFERREFERREFERREFERREFERREFER
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-DESCRIPTION
5-DESCRIPTION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-DESCRIPTION
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-DESCRIPTION
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-DESCRIPTION
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-DESCRIPTION
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-5-LOCATION
1-TAG
2-LOOP NUMBER
3-DESCRIPTION
4-DESCRIPTION
5-DESCRIPTION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-DESCRIPTION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-DESCRIPTION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION/SIZE
4-FURNISHED BY
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-LOCATION
1-TAG
2-LOOP NUMBER
3-FUNCTION
4-FURNISHED BY
5-DESCRIPTION
MWH - TSH - XSH - DISC - DISCONNECT
ACTIONALARM
NUM - NUMERIC
SP - SET POINTSTATUS
TREND
AI - ANALOG INPUTAO - ANALOG OUTPUT
DI - DISCRETE INPUTDO - DISCRETE OUTPUT
HSC - HIGH SPEED COUNTER INPUT
RTD - RTD INPUT
ACTIONALARM
NUM - NUMERIC
SP - SET POINTSTATUS
24VDC - 1P
120VAC - 1P
208VAC - 2P208VAC - 3P240VAC - 3P240VAC - 2P
480VAC - 3P
2400VAC - 3P
4160VAC - 3P
24VDC - 1P
120VAC - 1P
208VAC - 2P208VAC - 3P240VAC - 2P240VAC - 3P
480VAC - 3P
2400VAC - 3P
4160VAC - 3P - LCP - PCM -- LCP - MCC - PCM - VCP - VFD - 1 2
DESCRIPTION DESCRIPTIONDESCRIPTION
3 1 2 31 2 3
BUS ID
DEVICENETFOUNDATION FIELDBUS
DESCRIPTION
1 2 3
2 3
DESCRIPTION
33 DESCRIPTION DESCRIPTION DESCRIPTION
REFER
3 REFER REFER
1 3
DESCRIPTION DESCRIPTION
REFER REFER
1 3
REFER REFER
1 3
REFER REFER
1 3
REFER REFER
1 3
REFER
3 REFER
3 33
REFER
3 DESCRIPTION DESCRIPTIONDESCRIPTION DESCRIPTION
DESCRIPTION DESCRIPTIONDESCRIPTION DESCRIPTION AREA NO.
BUILDING NO.
ROOM NO.
DESCRIPTION DESCRIPTION AREA NO.
BUILDING NO.
ROOM NO.
DESCRIPTION DESCRIPTION DESCRIPTION
DESCRIPTION DESCRIPTION
MCP - SS - TM - XR - CR - IR - DESCRIPTION DESCRIPTION DP - LCP - LP - LIGHTING PANEL NO. MCC - PCM - PP - POWER PANEL NO. VCP - 2 5 66666 55 FIELD EQUIPMENT 1-TAG 2-LOOP NUMBER 3-TYPE 4-5- 120VAC -1P 208VAC -2P 208VAC -3P 240VAC -2P 240VAC -3P 480VAC -3P 2400VAC -3P 4160VAC -3P REFER 4 2 5 DESCRIPTION TM - 3 MS - RVAT - RVSS - VFD - DRIVE
DRAWING VISIBLE
FIELDS
FIELD - 1 FIELD - 2 FIELD - 3 FIELD - 4
INSTRUMENT BUBBLE LOCATIONS
1 2
3 POWER
SOURCE
FIELD
CONTROLPANEL
OPERATOR
INTERFACE/
CONTROL
DEVICES
NOTES
4 5
6 AREA NO.
BUILDING NO.
ROOM NO.
66 FVNR - FULL VOLTAGE
NON-REVERSING STARTER
FVR - FULL VOLTAGE REVERSING
STARTER
PWS - PART-WINDING STARTER
RVAT - REDUCED VOLTAGE AUTO
TRANSFORMER STARTER
RVSS - REDUCED VOLTAGE SOLID
STATE STARTER
TS1W - TWO SPEED SINGLE
WINDING
TS2W - TWO SPEED TWO WINDINGS
VFD - VARIABLE FREQUENCY
DRIVE
LCP - MCC -
PCM - VCP - 2
1 345
2121
21 345345
1221
345
21 345
21 345
345
1221
345345
12 21
345345
12 345
12 12
345
12 345
1 AM - AUTO/MANUAL
CL - CLOSE
FRLR - FIXED RATE/LEVEL RATE
HOA - HAND /OFF/AUTO
JOHC - JOG OPEN/HOLD/CLOSEJOJC - JOG OPEN/JOG CLOSE
LH - LOW/HIGHLOR - LOCAL/OFF/REMOTELOS - LOCK OUT STOP LS - LEAD/STANDBYLSR - LOCAL/STOP/REMOTE
NOOT - OC - OPEN/CLOSE
OLOL - ON LINE/OFF LINE OO - OFF/ONOP - OPEN OSC - OPEN/STOP/CLOSE
RST - RESET
SAAM - SEMI AUTO/AUTO/MANUAL SEL - SELECT SP - STOP SPD - SPEED SS - START/STOPST - START
INSTRUMENT TAG IDENTIFICATION LETTERS TABLE
OPERATOR PILOT DEVICE LEGEND
EQUIPMENT TAGGING TABLE
I/O TYPE DESIGNATIONS TABLEINSTRUMENT TYPE DESIGNATIONS TABLE FURNISHED BY:
VCP - RVSS BYPASS - BYPASS E-STOP - EMERGENCY STOP
PLC - CONTROLLER NO. - CONTROLLER NO. PAC CNET FF ---- DNET ENET - ETHERNET/IP MB+ MB - MODBUS RTU MODBUS PLUS
MBTCP - MODBUS TCP
DP - PROFIBUS DPPA - PROFIBUS PAPNET - PROFINET
OPERATOR INTERFACE
TERMINAL
HARDWIRED I/O
PILOT DEVICE
INTERFACE
VCP - RIO - REMOTE I/O
SERIAL - PROPRIETARY PROTOCOL
CONTROLNET
FBV
STARTER/DRIVE
CUBICLE/CABINET
TRANSITIONNO OFFLINE/OFFLINEBREAKERSOLID STATE CIRCUIT
6 3
3 CIRCUIT BREAKER
THERMAL MAGNETIC
CIRCUIT BREAKER
THERMAL MAGNETIC
PANEL NO. VENDOR CONTROLMODULE NO.PROCESS CONTROLCENTER NO. MOTOR CONTROLPANEL NO.LOCAL CONTROLPANEL NO.DISTRIBUTION DP - LCP - LP - LIGHTING PANEL NO.
MCC - PCM - PP - POWER PANEL NO.
VCP - PANEL NO. VENDOR CONTROL
MODULE NO.PROCESS CONTROLCENTER NO. MOTOR CONTROLPANEL NO.LOCAL CONTROLPANEL NO.DISTRIBUTIONPANEL NO.VENDOR CONTROLMODULE NO.PROCESS CONTROLPANEL NO.LOCAL CONTROLINTERFACE NO.DRIVE NO.FREQUENCYVARIABLEPANEL NO.VENDOR CONTROLSOLID STARTER NO.REDUCED VOLTAGEMODULE NO.PROCESS CONTROLCENTER NO.MOTOR CONTROLPANEL NO.LOCAL CONTROL PANEL NO.VENDOR CONTROL
LOGIC
PROGRAMMABLE
AUTOMATION
PROGRAMMABLE
PLC - CONTROLLER NO. - CONTROLLER NO. PAC
VCP - RIO - REMOTE I/O
PANEL NO.VENDOR CONTROL
LOGIC
PROGRAMMABLE
AUTOMATION
PROGRAMMABLE
PANEL NO.VENDOR CONTROLMODULE NO.PROCESS CONTROLCENTER NO.MOTOR CONTROLPANEL NO.LOCAL CONTROL
LCP - MCC -
PCM - VCP - PANEL NO. VENDOR CONTROL MODULE NO. PROCESS CONTROL CENTER NO.MOTOR CONTROLPANEL NO.LOCAL CONTROL
LCP - MCC -
PCM - VCP - PANEL NO. VENDOR CONTROL MODULE NO. PROCESS CONTROL CENTER NO.MOTOR CONTROLPANEL NO.LOCAL CONTROL
BREAKERCIRCUITCIRCUITBREAKER
HEATERWINDINGMOTORSWITCHTEMPERATURESWITCHTORQUE
FREQUENCY
VARIABLE
STARTERSOLID STATE
VOLTAGE
REDUCEDREDUCED
VOLTAGE AUTO
STARTERTRANSFORMER
STARTERMOTOR
RELAYINTERPOSINGRELAYCONTROLRELAYPROTECTION
XR - CR - IR - RELAY INTERPOSING RELAY CONTROL RELAY PROTECTION FIELD - 6 FIELD - 5 FIELD - 6
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
E - EXISTING
F - FUTURE
345345
6- 6
6666666
666
666
6 6
6-6-6-6-6-6-6- 6-6-6-6-6-6-6-6-6- SYMBOL 1 - 2 345 PROTECTOR MOTOR CIRCUIT SYMBOL 6 EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE EXISTING/FUTURE TRANSMITTER WITH INTEGRAL SINGLE INSTRUMENT
SINGLE INSTRUMENT
TRANSMITTER
WITH REMOTE
FBO FURNISHED BY OWNER
FURNISHED BY VENDOR
POWER SOURCEVOLTAGE-POLE
VOLTAGE-POLE
VOLTAGE-POLE
LOCAL OPERATOR LOCAL OPERATOR
HMI/SCADA SYSTEM
LOI
PCS
7 7-DIGITAL NETWORK TABLE
I/O
NETWORK / SOFTI/O
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:46:46PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
INSTRUMENTATION 00GN01
SYMBOLS AND ABBREVIATIONS 1 102
11843A1000GN01.dgn
ASR WELL
kkwarsick
CE
FUTURE
IDENTIFIER
UNIQUE
SHEETCONTINUATION
PIPE SIZE
ELEMENT
TRANSMITTER
INDICATINGTRANSMITTER
CONVERTER
TRANSDUCER,RELAY
SPECIALDEVICES
INDICATOR
RECORDER
CONTROLLER
INDICATINGCONTROLLER
RECORDINGCONTROLLER
SWITCH
SWITCHLOWLOW
SWITCHLOW
SWITCHHIGH
SWITCHHIGHHIGH
SWITCHCOMBINATION
HIGHLOW
ACTION
ALARMLOWLOW
ALARMHIGH
ALARMLOW
ALARMHIGHHIGH
TOTALIZEINDICATOR
TRANSMITTER
VALVE GAUGE LIGHT
SPEEDSETTING
ANALYSIS
BURNER FLAME
CONDUCTIVITY
DENSITY
FLOW
FLOW RATIO
GAUGING (DIMENSION)
CURRENT
A
B
C
D
E
F
FF
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
POWER
TIME
LEVEL
MOISTURE OR HUMIDITY
EMERGENCY SHUTDOWN
PRESSURE OR VACUUM
DIFFERENTIAL PRESSURE
QUANTITY
RADIOACTIVITY
SPEED
TEMPERATURE
DIFFERENTIAL TEMPERATURE
MULTIVARIABLE
VISCOSITY
WEIGHT
UNCLASSIFIED
VIBRATION
POSITION
AE
BE
CEDE
FE
ME
QE
SE
TE
VE
WE
XE
XVE
ZE
AT
BT
CTDT
FT
IT
LT
MT
PT
PDT
QT
ST
TT
TDT
VT
WT
XT
XVT
ZT
AIT
BIT
CITDIT
FIT
IIT
LIT
MIT
PIT
PDIT
QIT
SIT
TIT
TDIT
VIT
WIT
XIT
ZIT
AY
BY
CYDY
FY
FFY
IY
KY
LY
MY
PY
PDY
QY
SY
TY
TDY
VY
WY
XY
XVY
ZY
AI
BI
CIDI
FI
FFI
II
KI
LI
MI
PI***
PDI
QI
SI
TI
TDI
UI
VI
WI
XI
XVI
ZI
AR
BR
CRDR
FR
IR
KR
LR
MR
PR
PDR
QR
SR
TR
TDR
UR
VR
WR
XR
XVR
AC
BC
CCDC
FC
FFC
HC
IC
KC
LC
MC
PC
PDC
SC
TC
TDC
UC
VC
XC
AIC
BIC
CICDIC
FIC
FFIC
IIC
KIC
LIC
MIC
PIC
PDIC
SIC
TIC
TDIC
UIC
VIC
XIC
ARC
BRC
CRCDRC
FRC
IRC
KRC
LRC
MRC
PRC
PDRC
SRC
TRC
TDRC
URC
VRC
XRC
AS
BS
CSDS
FS
FFS
HS*
IS
KS
LS
MS
PDS
QS
SS
TS
TDS
US
VS
WS
XS
XVS
ASLL
BSLL
CSLLDSLL
FSLL
ISLL
KSLL
LSLL
MSLL
PSLL
PDSLL
QSLL
SSLL
TSLL
TDSLL
VSLL
WSLL
XSLL
ASL
BSL
CSLDSL
FSL
ISL
KSL
LSL
MSL
PSL
PDSL
QSL
SSL
TSL
TDSL
VSL
WSL
XSL
ASH
BSH
CSHDSH
FSH
ISH
KSH
LSH
MSH
PSH
PDSH
QSH
SSH
TSH
TDSH
VSH
WSH
XSH
XVSH
ASHH
BSHH
CSHHDSHH
FSHH
ISHH
KSHH
LSHH
MSHH
PSHH
PDSHH
QSHH
SSHH
TSHH
TDSHH
VSHH
WSHH
XSHH
XVSHH
ASHL
CSHLDSHL
FSHL
LSHL
PSHL
TSHL
AALL
BALL
CALLDALL
FALL
IALL
KALL
LALL
MALL
PALL
PDALL
QALL
SALL
TALL
TDALL
VALL
WALL
XALL
AAL
BAL
CALDAL
FAL
IAL
KAL
LAL
MAL
PAL
PDAL
QAL
SAL
TAL
TDAL
VAL
WAL
XAL
AAH
BAH
CAHDAH
FAH
IAH
KAH
LAH
MAH
PAH
PDAH
QAH
SAH
TAH
TDAH
VAH
WAH
XAH
XVAH
AAHH
BAHH
CAHHDAHH
FAHH
IAHH
KAHH
LAHH
MAHH
PAHH
PDAHH
QAHH
SAHH
TAHH
TDAHH
VAHH
WAHH
XAHH
XVAHH
FQI FCV
HV
KV
LCV
PCV
PDCV
TCV
TDCV
XCV
ZV
FG
LG
XG
AL
BL
CLDL
FL
FFL
HL
IL
KL
LL
ML
PL
PDL
TL
TDL
UL
VL
XL
XVL
HSS
LE
PE
HA*
PD
TD
XV
STATUS*** YI***
ZS**
MEASURED VARIABLE
INSTRUMENT FUNCTION
HAND (MANUAL)*
*** PI# # = 1,2,3 ETC. AND REPRESENTS A UNIQUE IDENTIFIER AND IS APPLICABLE TO ALL ITEMS IN THE TABLE ABOVE** LETTER INDICATES POSITION (O=OPEN, C=CLOSED, R=RAISE, L=LOWER, ETC)* REFER TO OPERATOR PILOT DEVICE LEGEND
PILOT DEVICE FUNCTION
DEVICE TYPE
SCADA/HMI TAG (HAND ACTION)
PILOT DEVICE TAG (HAND SWITCHES)
RESET(RST)
**** COULD ALSO BE PIS - FOR PRESSURE INDICATING SWITCH PS****
TO PROCESS
INSTRUMENT OR CONNECTION
(GUIDED)
ELECTROMAGNETIC OR SONIC SIGNAL
(NOT GUIDED)
ELECTROMAGNETIC OR SONIC SIGNAL
(SOFTWARE OR DATA LINK)
INTERNAL SYSTEM LINK
PNEUMATIC SIGNAL
ELECTRIC SIGNAL
HYDRAULIC SIGNAL
CAPILLARY TUBE
COPPER ETHERNET
FIBER OPTIC ETHERNET
WIRELESS ETHERNET
PROFIBUS DPPROFIBUS PA
DEVICENET
FOUNDATION FIELDBUS
IN PIPE
PRIMARY PROCESS FLOW
IN PIPE
SECONDARY PROCESS FLOW
IN CHANNEL
PRIMARY PROCESS FLOW
IN CHANNEL
SECONDARY PROCESS FLOW
EQUIPMENT ENCLOSUREEXISTING
DESIGNATIONS
MISCELLANEOUS P&ID SYMBOLS
PIPE CALLOUT
INSTRUMENT LINE SYMBOLS
PROCESS LINE SYMBOLS
YL
ZL**
MS
AUX1
AUXF1
AUXH1
AUXL1
AUXR1
SVC
SVO
MSF
MSM
MSP
MSR
MST
SS
RUNNINGRUNNING HIGH
SOLENOID VALVE OPEN
RUNRUNNING FORWARDRUNNING LOWRUNNING REVERSE
SOLENOID VALVE CLOSE
MOTOR START FORWARD
VALVE MODULATE
MOTOR STOPMOTOR START REVERSEMOTOR START
SPEED SIGNAL
PC
AM
COND
CL
HSF
IS
O3
P
P-SUB
PO
AMMONIA
CHLORINE PRESSURE SUBMERSIBLECONDUCTIVITY
FLUORIDE
INTRINSIC SAFETY BARRIER
OZONE
PRESSUREPARTICLE COUNTER
R/I RESISTANCE TO CURRENT
I/O TYPE DESIGNATIONS
LEL LOWER EXPLOSIVE LIMIT
ROT ROTAMETER
INSTRUMENT TYPE DESIGNATIONS
CAP CAPACITANCE
FMCW FREQ. MODULATED CONT. WAVE
MAG MAGNETIC
PTOF PULSE TIME OF FLIGHT
CC*
A PHASE
SPD
HTR
UPS
BPH
CPH
MWH
SV*
SPECIFIC ABBREVIATIONS
APH
BRB
BRT
BTFLY
B PHASE SSGBEARING BOTTOMBEARING TOPBUTTERFLY
C PHASE
MOTOR WINDING HEATER
HEATER
SOLENOID VALVE
UVI
UVT
VAC
SC
TURB
US
TURBIDITY
STREAMING CURRENT
ULTRASONICUV INTENSITYUV TRANSMITTANCE
VACUUM
SH SODIUM HYPOCHLORITE
TDR TIME DOMAIN REFLECTOMETRY
TH THERMAL
DO DISSOLVED OXYGEN
ORP
RTD
TSS TOTAL SUSPENDED SOLIDS
OXIDATION REDUCTION POTENTIAL
RESISTANCE TEMP DETECTOR
AUX2
PHOSPHOROUS
SECONDARY SWITCHGEAR
* CC# AND SV# # = 1, 2, 3 ETC. AND REPRESENTS A UNIQUE IDENTIFIER YA
MSH MOTOR START HIGH
MSL MOTOR START LOW
HTU HEAT TRACE UNIT
SURGE PROTECTIVE DEVICE
FAILED/FAULT
Y1 STATUS RUNNING
Y2 ALARM FAILED/FAULT
YR STATUS REMOTE
STATUS AUTO
ZCO POSITION COMMAND OPEN
ZCC POSITION COMMAND CLOSE
ZC POSITION COMMAND
FUTURE
SIGNAL CONTINUATION
CGD COMBUSTIBLE GAS DETECTOR
CALIBRATION COLUMN
UNINTERRUPTIBLE POWER SUPPLY
INSTRUMENT TAG IDENTIFICATION LETTERS (PER ROSEVILLE DEVICE NAMING STANDARD APPENDIX F, TAG PREFIXES ARE 4 CHARACTERS LONG)
HOAORLOASWITCH
"AUTO"OR"NOTINAUTO"FROM
HSAX
HCAX
"STOP"STATUS
"START"STATUS
OFF-ON(OO)SWITCHSTATUS
HSBX
HCBX
HSCX
HCCX
HSEX
CLOSEDPOSITION
HSGX
HCGX
HSLX HSMX HSNX HSOX
HCOX
HSRX
HCRX
HSWX HSXX
HCXX
LOAORHOASWITCH
"LOCAL"OR"HAND"FROM
STATUS
"MAINTENANCEMODE"
"ESTOP"STATUS
OPENPOSITION
"INTRUSIONBYPASS"STATUS
-AKALOCAL/REMOTE
"LOCAL/AUTO"SWITCHSTATUS
(PER ROSEVILLE SCADA AND P&ID TAG NAMING STANDARD 06062018)
OPERATOR PILOT DEVICE LEGEND
#
DESC1_DESC2_
PROCESS CONTINUATION DWG NO.
TO DRAWING FROM DRAWING
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:48:10PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
INSTRUMENTATION 00GN02
SYMBOLS AND ABBREVIATIONS 2 103
11843A1000GN02.dgn
ASR WELL
kkwarsick
CE
FOOT VALVE
BASKET STRAINER
COALESCER
EDUCTOR/EJECTOR
BLOW-OFF SILENCER
AIR DAMPER
FILTERFILTER SEPARATOR
EYEWASH
DRYERDESICCANT
COLUMNCALIBRATION
DIFFUSER
AIR / CHEMICAL
ACTUATORS
O
C
BALL
DOUBLE FLAP
FLAPPER
SWING
CHECK VALVES PRESSURE VALVES
REGULATING
PRESSURE RELIEF
VACUUM RELIEF
S
VALVES
AIR-RELIEFANGLE
BALLBUTTERFLY
CONE
DIAPHRAGM
3-WAY PLUG
4-WAY
3-WAY
BALL V-NOTCH
GATEGLOBE
HOSE
MUD
NEEDLE
PINCHPLUG ECCENTRIC
PLUG CONCENTRIC
TELESCOPING
PUMP DISCHARGE
S
P
S
P
S
DIAPHRAGMPNEUMATIC
HANDHYDRAULIC
SS
SS
S
P
S
P
~
IY
I/P
PIPING
AIR GAP
BLIND FLANGE
DRAIN
PUMPS
AIR DRIVEN
CENTRIFUGAL
DIAPHRAGM
GEAR
PISTON
SUBMERSIBLE
WATER CHAMP
FAN
MISC
H
VALVE DESIGNATIONS
NO NORMALLY OPENNC NORMALLY CLOSED
FO FAIL OPENFC FAIL CLOSEFLP FAIL LAST POSITION
S SOLENOIDP
DISCRETE
ELECTRIC
MODULATING
ELECTRIC
HYDRAULIC
ELECTRIC
MODULATING
HYDRAULIC
OPEN/CLOSE
SINGLE SOLENOID
PNEUMATIC
w/ SPEED CONTROL
SINGLE SOLENOID
PNEUMATIC
OPEN/CLOSE
DUAL SOLENOIDPNEUMATIC
OPEN/HOLD/CLOSE
DUAL SOLENOIDPNEUMATIC
w/ SPEED CONTROL
OPEN/CLOSE
DUAL SOLENOIDPNEUMATIC
MODULATING
PNEUMATIC
w/ SPEED CONTROL
OPEN/CLOSE
MODULATING
PNEUMATIC
PLUGGED
CAPPED OR
INCREASER
CONCENTRIC
REDUCER
CONCENTRIC
INCREASER
ECCENTRIC
REDUCER
ECCENTRIC
COUPLING
EXPANSION
CENTER
VIBRATION
EXPANSION JOINT
CONNECTION
FLEXIBLE
DISCONNECT
QUICK
OR HOSE
PERISTALTIC
CAVITY
PROGRESSIVE
TURBINE
VERTICAL
CHOPPER
VERTICAL
BLOWER
SINGLE STAGE
CENTRIFUGAL
BLOWER
MULTI STAGE
CENTRIFUGALCOMPRESSOR
RECIPROCATING
COMPRESSOR
SCREW
COMPRESSOR
LIQUID RINGBLOWER
ROTARY LOBE
-BURIED VALVE BOX
PLUG CONCENTRIC
LUBRICATED
PLUG CONCENTRIC
BOXBURIED VALVELUBRICATED
PLUG CONCENTRIC
w-VALVE BOX
PLUG ECCENTRIC
LUBRICATED
PLUG ECCENTRIC
VALVE BOX
LUBRICATED BURIED
PLUG ECCENTRIC
BURIED VALVE BOXBUTTERFLYPRESSURE TAP
EXTERNAL
REDUCING
PRESSURE
SELF CONTAINED
REDUCING
PRESSURE
EXTERNAL TAP
REGULATING
BACKPRESSURE
SELF CONTAINED
REGULATING
BACKPRESSURE
SWINGSPRING LOADED
GENERAL
SPRING LOADED
CHECK
DIAPHRAGM
COMPRESSORS
BLOWERS/
UNION
TEE
PPP
DIAPHRAGM
CHEMICAL FEED
OR
M
E
H
E
D
E
M
PREVENTER
BACK FLOW
VALVE BOX
GATE-BURIED
GRINDER
HEAT EXCHANGERHORIZONTAL MIXER
FLAME ARRESTERFINE FILTER HOSE CONNECTION
INLET STRAINER
FIRE ALARM/SENSOR
HOIST
EXHAUST FAN
INLINE STATIC MIXER
MATERIAL CHANGE
VALVE
OPERATED
w/THERMALLY
FLAME ARRESTER
LOCATOR
EQUIPMENT/INSTRUMENT
VAPORIZER
GAS CANNON
FLOW CONDITIONER
MIXER
MOTOR
NOZZLE
RUPTURE DISK
SAMPLE PORTSIGHT TUBE
VAPOR HEATER
OR
SMOKE DETECTOR
SAMPLER
COMPOSITE
PERISTALTIC
RESTRICTION
ORIFICE
DAMPENERPULSATIONDRYER
REFRIGERATED
CLEANED
MECHANICALLY
STRAINER -
WITH BLOW OFF
STRAINER
WYE TYPE
STRAINER
ATMOSPHERE
VENT TOVENT
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:48:14PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
INSTRUMENTATION 00GN03
SYMBOLS AND ABBREVIATIONS 3 104
11843A1000GN03.dgn
ASR WELL
kkwarsick
CE
PRESSURE SWITCH
ORIFICE
DISPLACEMENTPOSITIVEVORTEX
V-CONE
THERMAL
BATCH
CORIOLIS
MAGNETIC
PADDLE WHEEL
ROTAMETER
BUBBLER
CAPACITANCE
ELECTRODE
FLOAT
INVERTED COLUMN
RADAR PTOFRADAR TDR
ULTRASONIC
GAUGE
PRESSURE SWITCH
KNIFE
SLIDESLUICESTOP
SLIDESLUICESTOP
FLAP
WEIR
PARSHALL
LEOPOLD-LAGCO
PALMER-BOWLUS
TRAPEZOIDAL
CUTTHROAT
REGULAR
w/ END CONTRACTIONS
RECTANGULAR
TURBINE
PROPELLEROR FLOW NOZZLE
VENTURI TUBE
PRESSUREDIFFERENTIAL
SUBMERSIBLESUSPENDED/
MM
ANNULAR
SEAL
DIAPHRAGM
SEAL
SANITARYSEAL
PE
PSH
PE
PSH
MANOMETER
PRESSURE DIFFERENTIAL PRESSURE PRESSURE SEALS
PI PDI
PDSL
PDE
INDICATOR
DIFFERENTIAL
GAUGE
PE
PIT
TRANSMITTER
PRESSURE
SWITCH
PRESSUREDIFFERENTIAL
PDIT
PDE TRANSMITTER
PRESSUREDIFFERENTIAL
TUNING FORK
PISTON
WEIRS
SIDE VIEW PLAN VIEW
FLOW FLUMES LEVEL
K
N
A
T
PDE LDIT
SIDE VIEW PLAN VIEW
w/o END CONTRACTIONS
RECTANGULAR
w/o END CONTRACTIONS
RECTANGULAR
w/ END CONTRACTIONS
RECTANGULAR
(TRIANGULAR)
V-NOTCH
(TRIANGULAR)
V-NOTCH
(CIPOLLETTI)
TRAPEZOIDAL
(CIPOLLETTI)
TRAPEZOIDAL
PRESSURE/VACUUM
EXAMPLE
GATES
PITOT TUBE
ANNUBAR
ULTRASONIC
BIOGAS
ULTRASONIC
THERMOMETER
HYDRAULIC
STRAIN GAUGE
w/THERMOWELL
TEMPERATURE
GAUGE
TEMPERATURE
T
WEIGHT
TEMPERATURE
PROBE
CONTINUOUS WAVE)
MODULATED
(FREQUENCY
RADAR
BUTTERFLY
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:46:52PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
INSTRUMENTATION 00GN04
SYMBOLS AND ABBREVIATIONS 4 105
11843A1000GN04.dgn
ASR WELL
kkwarsick
CE
1 # KEY NOTES:
1. REFER TO GN02 FOR ADDITIONAL ISA ABBREVIATIONS.
1 ACRONYM DESCRIPTION
INJR INJECTOR - CL2 / SO2
LCPx LOCAL CONTROL PANEL
LDBK LOAD BANK
LITx LEVEL INDICATING TRANSMITTER
LPxx LIGHTING PANEL
LSPx LOAD SHED RELAY PANEL
LUBE LUBRICATING OIL SYSTEM
MCCx MOTOR CONTROL CENTER
MIXR MIXER
MODL LAMP MODULE
MONT MONITOR (WATER CANNON )
MODx MOTOR OPERATED DOOR
MOGx MOTOR OPERATED GATE VALVE
MOVx MOTOR OPERATED VALVE (SLIDE, BALL, GLOBE…)
MSTR MOTOR STARTER
MTRB MICROTURBINE
MTRx MOTOR
MTSx MANUAL TRANSFER SWITCH
MVFD MOTOR V.F.D.
ODOR ODOR SCRUBBING SYSTEM
PCxx PERSONAL COMPUTERS
PDCu POWER DISTRIBUTION CENTER (ULTRA-VIOLET)
PEDx METERING PEDESTAL
PITx PRESSURE INDICATING TRANSMITTER
PMIX POLYMER MIXING UNIT
POND TREATMENT PLANT EMERGENCY OR PROCESS STORAGE
POVx PNEUMATICALLY OPERATED VALVE
PPxx POWER DISTRIBUTION PANEL, PANELBOARD
PLCx PROGRAMMED LOGIC CONTROLLERS
PLCP PLC PANEL
PQMx POWER QUALITY MONITOR
PUMP PUMPS - ALL TYPES
PWRS POWER SUPPLY (USE UPSx FOR UNINTERRUPTIBLE POWER
RADx RADIO SYSTEMS
RADI RADIATORS
RDTx ROTARY DRUM THICKENER
RELx RELAY, MULTI-FUNCTION ELECTRICAL PROTECTIVE
RESP RESPIRATORS (FULL & HALF FACE, AIR SUPPLIED, AIR
RVSS REDUCED VOLTAGE SOFT STARTER
SAMP SAMPLER UNIT
SECR SECURITY SYSTEMSSRVR SERVER, SCADA / CONTROL
SBFP SLUDGE BELT FILTER PRESS
SGAT GATE: SLIDE, SLUICE, KNIFE
SKMR SKIMMERS: SLUDGE, SCUM
SOVx SOLENOID OPERATED VALVE
SPDx SURGE PROTECTIVE DEVICE (TVSS & SPD)
STAT STATION (PUMPING, PRESSURE REDUCING…)
STNR STRAINERS
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TANK TANKS, STORAGE VESSELS, PRESSURE ACCUMULATORS
TCOM TELECOMMUNICATIONS SYSTEMS
TCPx TEMPERATURE CONTROL PANEL
TITx TEMPERATURE INDICATING TRANSMITTER
TOOL TOOLS, LATHES, MILLS, SHEARS, PRESS
TRAP TRAPS: DRIP, CONDENSATE
UPSx POWER SUPPLY, UNINTERRUPTIBLE
UVRx ULTRAVIOLET BANK
VALV VALVES: BALL, GATE, GLOBE, BUTTERFLY - ALL TYPES
VFDx DRIVE, VARIABLE FREQUENCY
VGLV VOLTAGE GLOVES
VSCD VISCOUS, HYDRAULIC DRIVE / TORQUE CONVERTER
WEIR FLOW REGULATION WEIR
WASH WASHER / COMPACTOR
WITx WEIGHT INDICATING TRANSMITTER
WKST WORKSTATION, SCADA / CONTROL
XFMR TRANSFORMER
SYSTEM
DESIGNATOR
SUB-SYSTEM
DESIGNATOR
SCADA
DESCRIPTION
ALARM
0 COMMON SUPPORT FACILITIES
1 WD ADMINISTRATION
2 WD SHOP FACILITIES
3 WD WAREHOUSE / STORAGE
4 WD LABORATORY
5 WD
UTILITIES (HVAC, SANITARY SEWER, POTABLEUTILITY WATER, COMPRESSED AIR) 6 WD ELECTRICAL DISTRIBUTION7 WD COMMUNICATIONS / OFFICE NETWORKING8 WD
SCADA / PLANT NETWORKING / HDR, RADIO BASESTATION, SECURITY & FIRE SYSTEMS 9 WD
HEALTH & SAFETY (PPE, PORTABLE GASGAS DETECTORS, FIRE SYSTEMS, SECURITY 10 TRANSMISSION
11 WD ELECTRICAL & CONTROL (PLC, PP, MCC, RADIO)
12 WD
13 WD PROCESS CHEMICAL / PHYSICAL ADJUSTMENT
14 WD PRODUCT CONVEYANCE
15 WD PROCESS BASINS / TANKS / CHANNELS
16 WD17 WD BUILDINGS / STRUCTURES / VAULT / SUMPS
18 WD19 WD
20 DISTRIBUTION
21 WD ELECTRICAL & CONTROL (PLC, PP, MCC, RADIO)
22 WD
23 WD PROCESS CHEMICAL / PHYSICAL ADJUSTMENT
24 WD PRODUCT CONVEYANCE
25 WD PROCESS BASINS / TANKS / CHANNELS
26 WD27 WD BUILDINGS / STRUCTURES / VAULT / SUMPS
28 WD29 WD
30 WELLS
31 WD ELECTRICAL & CONTROL (PLC, PP, MCC, RADIO)
32 WD
33 WD PROCESS CHEMICAL / PHYSICAL ADJUSTMENT
34 WD PRODUCT CONVEYANCE
35 WD PROCESS BASINS / TANKS / CHANNELS
36 WD
37 WD BUILDINGS / STRUCTURES / VAULT / SUMPS
38 WD AQUIFER STORAGE SYSTEM
39 WD
40 STORAGE
41 WD ELECTRICAL & CONTROL (PLC, PP, MCC, RADIO)
42 WD
43 WD PROCESS CHEMICAL / PHYSICAL ADJUSTMENT
44 WD PRODUCT CONVEYANCE
45 WD PROCESS BASINS / TANKS / CHANNELS
46 WD47 WD BUILDINGS / STRUCTURES / VAULT / SUMPS
48 WD49 WD
50 INTERTIES
51 WD ELECTRICAL & CONTROL (PLC, PP, MCC, RADIO)
52 WD
53 WD PROCESS CHEMICAL / PHYSICAL ADJUSTMENT
54 WD PRODUCT CONVEYANCE
55 WD PROCESS BASINS / TANKS / CHANNELS
56 WD57 WD BUILDINGS / STRUCTURES / VAULT / SUMPS
58 WD59 WD
CG COMPRESSED NATURAL
DC DRY CREEK WWTP
FD FIRE DEPARTMENT
PG PLEASANT GROVE WWTP
PD POLICE DEPARTMENT
PR PARKS AND RECREATION
RW RECYCLED WATER
SO SOLID WASTE
SW STORM WATER
WT BARTON RD WTP
WC WASTEWATER COLLECTION
WD WATER DISTRIBUTION
REMOTE
STATION
DESIGNATOR
DESCRIPTION
0 PRIMARY FACILITY
1 PRESSURE REDUCING STATION, 1589 PLEASANT GROVE BLVD
2 PRESSURE REDUCING STATION, 1303 CANEVARI DR (AKA
WOODCREEK OAKS)
3 PRESSURE REDUCING STATION, BLUE OAKS BLVD
4 PRESSURE REDUCING STATION, JUNCTION BLVD (WEST #2)
5 PRESSURE REDUCING STATION, 3400 BASELINE ROAD (WEST
6 PRESSURE REDUCING STATION, 2054 PFE7 UNUSED
08 – 19 PRESSURE REDUCING STATIONS – FUTURE
20 WELL 1 401 ATLANTIC STREET (SHORT STREET)
21 WELL 3 CHURCH STREET (DECOMMISSIONED)
22 WELL 2 PACIFIC STREET (DECOMMISSIONED)
23 WELL 4 1002 DARLING WAY (DARLING)
24 WELL 5 1746 CHELSEA WAY (OAKMONT)
25 WELL 6 1490 NORTH PARK DRIVE (DIAMOND CREEK)
26 WELL 7 WOODCREEK NORTH27 WELL 8 2100 HAYDEN PARKWAY
28 WELL, WEST SIDE DRIVE (FUTURE), WELL 9 WESTBROOK BLVD29 WELL 12 1745 BLUE OAKS BLVD 30 WELL 13 HEWLETT PACKARD
31 WELL 14 FIDDYMENT ROAD
32 WELL, SIERRA VISTA SPECIFIC PLAN #1
33 WELL, SIERRA VISTA SPECIFIC PLAN #2
34 – 40 WELL SITES - FUTURE #35 WELL 18 SOLAIRE DRIVE
41 RESERVOIR – NORTHEAST
42 RESERVOIR – BARTON ROAD
43 RESERVOIR – STONERIDGE
44 UNUSED
45 UNUSED
46-50 RESERVOIR - FUTURE
51 PUMP STATION – DUAL PURPOSE
52 PUMP STATION – HIGHLAND RESERVE, 9300 FAIRWAY DR
53 PUMP STATION – 1589 PLEASANT GROVE BYPASS PUMP STN
54 PUMP STATION – 4501 WESTPARK DRIVE RESERVOIR AND PUMPING STATION 55 PUMP STATION – 2054 PFE BYPASS PUMP STN
56 – 60 PUMP STATION - FUTURE
61 INTER-TIE - PCWA TINKER
62 INTER-TIE – PCWA CROWDER
63 INTER-TIE – PCWA STONERIDGE
64 INTER-TIE – PFE
65 INTER-TIE – BARTON ROAD (9341 BARTON ROAD)
66 INTER-TIE – BIANCHI (3551 BASELINE ROAD)67 INTER-TIE – BLOSSOM HILL (1406 BLOSSOM HILL WAY) 68 INTER-TIE – CAVITT (8098 SIERRA COLLEGE BLVD)69 INTER-TIE – FIVE STAR (6712 STANFORD RANCH ROAD) 70 INTER-TIE – HIGHLAND (9000 HIGHLAND PARK DR)
71 INTER-TIE – ORLANDO (1205 ORLANDO AVE)
72 INTER-TIE – PLEASANT GROVE (600 PLEASANT GROVE BLVD) 73 INTER-TIE – SIERRA COLLEGE (9200 SIERRA COLLEGE BLVD) 74 INTER-TIE – VERNON OAKS (651 VERNON OAKS DR)
75 INTER-TIE – AMERICAN VINEYARD VILLAGE
76 INTER-TIE – BUREAU OF RECLAMATION 72” RAW WATER
76-94 INTER-TIE – FUTURE
95-98 MISCELLANEOUS WD RELATED REMOTE SITES
99 316 REPEATER LOCATION
ACRONYM DESCRIPTION
ADFF DIFFUSER, AERATION
AERD AERATOR, DISC
AERS AERATOR, SURFACE
AFHx ACTIVE HARMONIC FILTER
AGIT AGITATOR
AITx ANALYZER INDICATING TRANSMITTER
ATSx AUTOMATIC TRANSFER SWITCH (USE MTSx FOR MANUAL
TRANSFER SWITCH)
BASN BASIN: SED BASIN, AERATION BASIN, U.V. CONTACT BASIN
BATT BATTERIES
BCHG BATTERY CHARGER
BFPx PRESS, BELT FILTER
BIOA BIO-ASSAY
BOIL BOILER
BLDG BUILDING
BLWR BLOWERS: CENTRIFUGAL, ROTARY LOBE
BKRx BREAKER, ELECTRICAL
BRNR BURNERS
BSCR BAR SCREEN
BCKT BUCKET (CONTROLS COMPARTMENT LOCATED IN SWGR OR
CAMx CAMERA
CAPx CAPACITOR, POWER FACTOR CORRECTION
CENT CENTRIFUGE
CHAN CHANNEL, PROCESS FLOW
CLAR CLARIFIER: PRIMARY, SECONDARY
CLAS CLASSIFIER, GRIT
CNVR CONVEYOR
COLL COLLECTOR, SLUDGE
COMP COMPRESSORS - ALL TYPES
CTFN COOLING TOWER FAN
CTWR COOLING TOWERS
DAMP VENTILATION AIR DAMPER
DISP DISPENSER (CNG)
DITx DENSITY INDICATING TRANMITTER
DRVc CENTRIFUGE DRIVE
DRYR GAS DRYER / DESICANT
EDUC EDUCTOR (VENTURI NOZZLE)
EGEN EMERGENCY GENERATOR
ENGN ENGINE: DIESEL BACK-UP, INTERNAL COMBUSTION
EVAP EVAPORATORATIVE COOLER
EXCH EXCHANGERS, HEATED SLUDGE
FANx FAN, COOLING OR VENTILATING
EWSS EYEWASH – SAFETY SHOWER STATIONS
FALL FALL RESTAINT, FALL PROTECTION
FGSD FIXED GAS DETECTOR
FIRE FIRE SYSTEMS
FITx FLOW INDICATING TRANSMITTER
FLAS FLASH PROTECTION EQUIPMENT (FACE SHIELDS, SUITS )
FSCR FINE SCREENS
FLTR FILTER: EFFLUENT FILTER AND MECHANICAL FILTERS
FQxx FLOW TOTALIZER (MECHANICAL COMPOUND OR TURBO
GAGE GAUGES: PRESSURE, TEMPERATURE, VACUUM - ALL TYPES,
CALIBRATION COLUMNS
GATE ENTRY/EXIT VEHICLE, PERSONNEL
GCND GAS CONDITIONING EQUIPMENT
GENx GENERATOR
GRBT GRAVITY BELT THICKENER
GRBX GEAR BOX: INCREASER, REDUCER - ALL TYPES
GRND GRINDER
HEAT HEATER: BLOCK, PIPE, STRIP
HPGN SODIUM HYPOCHLORITE GENERATOR
HPRx HOPPER
HSTS HOISTS / CRANES
HVAC HEATING, VENTILATION, AIR CONDITIONING: CLIMATE
HXGR HEAT EXCHANGER, DEMAND HEATERS, HOT WATER TANKS
HYDc HYDRAULIC UNIT, CENTRIFUGE
HYDu HYDRAULIC POWER UNIT (ULTRAVIOLET)
HYDx HYDRAULIC POWER UNIT
IJBx INSTRUMENT JUNCTION BOX
EQUIPMENT TAGGING SYSTEM
XX # #_XXX X_# # # # #
FACILITY
SYSTEMSUB-SYSTEMFUNCTIONMODIFIERREMOTE STATION DESIGNATORPRIMARY EQUIPMENTEQUIPMENT
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:48:53PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
INSTRUMENTATION 00GN05
SYMBOLS AND ABBREVIATIONS 5 106
11843A1000GN05.dgn
ASR WELL
kkwarsick
CE
TERMINAL PANEL
PCM-300
PLC
MCC-1201
VFD
REMOTE
REMOTE
STOP
START
REMOTE
AUX1-210
RUNNING
FAIL
AUX2-210
WINDINGMOTORMWH-210HEATERMOTORCONNECTION
J-BOX
J-BOX
MWH
210
PMP
210
TSH
210
PSH
210
PE
210
M
J-BOX
SPEED INLOCALHSAL-210LOCALMODE
FIT
210
FE
210
FQT
210
OFF
LOCAL REMOTE
xoooox
STOPLOCALHSB-210
STOP
HSC-210LOCALSTART
LCP-210
PMP-210UTILITY WATER PUMPMOTOR:
INV. DUTY, TEFCTOSHIBA MODEL: XYZ
PUMP
200 GPM @ 20 FT TDH
900-1800 RPM
GOULD MODEL: XYZ
MODEL: XYZRANGE: 0-200 PSIGSETPOINT: 50 PSIGENDRESS HAUSERCAT NO.: XYZFLOW RANGE: 200-2500 GPMFLOW TOTAL: 1 PULSE/500 GAL (PSH210-1/PCM300-CB1300H2)
(PSH210-2/PCM300-C0001)
AQ0001+
AQ0001-
SHLD
FU1300-P1
FU1300-M1
<BLK-1><WHT-1>
FU1300-H1
I001
<BLK>
Q001A
<BLK>
Q001B
<RED>
E-STOP
Q002A
<BLU>
C0001
Q002B
CB1-210HCB1-210N
120VAC
FU1300-P2
FU1300-M2
FU1300-P3
<BLK-1><WHT-1><BLK-2><WHT-2>
C0004
FU1300-H3
I003
<BLU>
I004
FU1300-H4
<ORG>
FU1300-H5
I006
<YEL>
(VFD210-11,12/PCM300-AQ001)(VFD210-13,14/PCM300-AI001)
(VFD210-15/PCM300-Q001A)(VFD210-16/PCM300-Q001B)(VFD210-17/PCM300-Q002A)(VFD210-18/PCM300-Q002B)(FIT210-L/PCM300-CB1210H)(FIT210-N/PCM300-CB1210N) (FIT210-1,2/PCM300-AI002)(FQT210-4,5/PCM300-FU1300P3; C0004)(VFD210-20/PCM300-I003)(VFD210-22/PCM300-I004) (LCP210-3/PCM300-FU1300H5)
(LCP210-4/PCM300-I006)
(MWH210-H/VFD210-33)(MWH210-C/VFD210-X2)(PMP210-T1/VFD210-T1)(PMP210-T2/VFD210-T2)(PMP210-T3/VFD210-T3) (TSH210-NC/PCM300-CB1300H1)
(TSH210-C/PCM300-I001)(LCP210-P1/VFD210-1)
(LCP210-P2/VFD210-2)(LCP210-P3/VFD210-3)
(LCP210-1/VFD210-5)(LCP210-2/VFD210-6)(LCP210-5/VFD210-7)(LCP210-6/VFD210-8)(LCP210-7/VFD210-9)(LCP210-8/VFD210-10) HSS
210
HSA
210
HSB
210
HSC
210
FE/FIT/FQT-210PE/PSH-210
START
(CB1300-H)
AI001+
SHLD
FU1300-H2
C0002C0003
(VFD210-24/PCM300-C0003)(VFD210-23/PCM300-C0002)
(VFD210-19/PCM300-FU13000H3)(VFD210-21/PCM300-FU1300H4) SHLD
AI002+
120 VAC
MODEL: XYZ
PHOENIX
GND
SHLD
(C0002)(C0003)(C0001)(CB1300-H6) (I005)(C0004)(FU1300-M3)(CB1300-H7) (I002) (PSH210-1/PCM300-C001)(PSH210-1/PCM300-FU1300H2)(TSH210-NC/PCM300-I001)(TSH210-NC/PCM300-FU1300H1) (FU1300-P)
MM
(CB1-300N1)
1 2
3 4
5 67
8 210
%AQ001SPEED OUTRACK 1SLOT 2
12 210
%AI001SPEED INRACK 1SLOT 3
TSH
210
%I001MTR TEMPRACK 1SLOT 4
MSP
210
%Q001STOPRACK 1SLOT 5
PSH
210
%I005HI PRESSRACK 1SLOT 4
F
210
%AI002FLOWRACK 1SLOT 2
FQ
210
%I002FLOW TOTRACK 1SLOT 4
AUX1
210
%I003RUNNINGRACK 1SLOT 4
AUX2
210
%I004FAILRACK 1SLOT 4
HSAR
210
%I006REMOTERACK 1SLOT 4
210
%Q002STARTRACK 1SLOT 5
834
1112
7564334
10 9121122
315 6
2442
5 613
2324222119201817151614131211
T3T1T2
X2
33 9
10 87654213
CR1
210
CR2
210
120 VAC
MODEL: XYZ
PHOENIX
UTILITY WATER HIGH PRESSUREUTILITY WATER FLOW METER
120 VAC
24 VDC
CB1-300H
FU1-300P
+- FU1-300M
CB1-300N (CB1300-N)
SS-210SB-210
SSSB
OUT
SPEED
IN
SPEED
VFD-210
SECTION - 3
CUBICLE - 2
30HP, 480VAC, 42 AMPS
CONSTRUCTION. THE LOOP DIAGRAM SHOWN ABOVE DISPLAYS THE LEVEL OF EXPECTED DETAIL.
DIAGRAMS FOR THE ENTIRE FACILITY. PRELIMINARY DETAILED LOOP DIAGRAMS TO BE SUBMITTED FOR REVIEW PRIOR TO BEGINNING THE ABOVE DRAWING IS INCLUDED AS AN EXAMPLE ONLY AND IS NOT PROJECT SPECIFIC. CONTRACTOR SHALL FURNISH LOOP C-01-002
S-01-001
S-01-003
L-01-001
C-01-001
C-01-003
P-01-001 P-01-002
S-01-002
P1
P2
P3
MSP-210
MS-210 MS
H
CC
1 2
L
N
G
1 2
4 5
T1
T2
T3
NC
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:47:00PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
INSTRUMENTATION 00GN06
SAMPLE LOOP DRAWING 107
11843A1000GN06.dgn
ASR WELL
kkwarsick
CE
SECURITY SERVER
CITY C-CURE 9000 DOOR ACCESS/
BARTON RD WTP
THROUGH CITY NETWORK
VPN TUNNELS
IN SCADA DMZ
CONTROLLERS THRU PROXY SERVER
COMMUNICATES WITH EDGE
CITY MANAGED SERVER FW-WTP01
FW-WTP02
SCADA SERVER
SCADA NETWORKSCADA NETWORKSCADA NETWORK
172.17.185.230QOGNIFY VMSVIDEO SERVER
ELECTRICAL ROOM
WD31-PLCP-30101PLC PANEL
WD31-PLCX-30101MODICON M340PLC
WD08-FRWL-30100PA-220RFIREWALL
WD08-NVRX-30300
SSIQ8-R2-8S
VIDEO RECORDER
WD34-VFDX-30101WELL PUMP VFD
40NKS-0000044CCARD READERSGATE AND MAIN DOOR
PUMP ROOM
CHEMICAL ROOM
WD34-FITX-30104
WELL PUMP FLOW METER
WD08-NVRX-30301
SSIQ8-R2-8S
VIDEO RECORDER
PUMP BLDG
WD33-PLCX-30210MODICON M340PLC
S-WATER-WELL13MERAKI MS120-8FPSWITCH
OPTIC HANDHOLEWELLSITE FIBER
PROVIDED BY THE CITY(INCLUDING THE HANDHOLE)PROVIDED BY THE CONTRACTOR WD31-PQMX-30104SWITCHBOARD POWER METER
WD33-PLCP-30210CONTROL PANELSODIUM HYPOCHLORITE
WD08-CKEY-30900
GSTAR004-POE
CARDKEY
WD08-PCXX-30102DELL/WYSE 5070THIN CLIENTWD08-HMIX-30102HIS-ML23-STTDOPERATOR INTERFACE WD08-PCXX-30103DELL/WYSE 5070THIN CLIENTWD08-HMIX-30103HIS-ML23-STTDOPERATOR INTERFACE WD08-CAMX-30302
Q3536-LVE DOME STYLE AXIS
SECURITY CAMERA
WD08-CAMX-30304 THRU 30307Q3536-LVE DOME STYLE AXISSECURITY CAMERA WD08-CAMX-30301
Q3536-LVE DOME STYLE AXIS
SECURITY CAMERA
WD08-CAMX-30303
Q3536-LVE DOME STYLE AXIS
SECURITY CAMERA
WD08-ESWX-30101ARUBA R8N89ASWITCH
(PROVIDED BY OTHERS)WD08-CAMX-30308 & 30309LP READER CAMERA
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:47:16PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
JKR
TCD
INSTRUMENTATION 13GN01
108
11843A1013GN01.dgn
#
GENERAL NOTES:
KEY NOTES:
1 4
4 3
2 5
CAMPUS OAKS ASR WELL
GEB
CONNECTION DIAGRAM
TERMINATION PANEL.
8. CORNING SPH-01P-DIN IS THE END USER'S PREFERRED
CABLE.
7. CORNING ALTOS IS THE END USER'S PREFERRED FIBER OPTIC 6. NETWORK PROTOCOL IS MODBUS TCP.5. THE NETWORK IS ALL UNDER THE SAME SUBNET.4. THE NETWORK SPEED IS 1GB.3. FIBER OPTIC CABLE SHALL BE SINGLE MODE.2. FIBER OPTIC CONNECTORS SHALL BE LC TYPE.1. ALL ETHERNET CABLE SHALL BE CAT6.6. RS-485 ALARM RELATED SENSORS FROM PLC PANEL RELAYS.
5. SHALL HAVE A DI CARD AND CONNECT ALL DOOR CONTACTS AND UBUNTU OPERATING SYSTEM.
4. THE THIN CLIENTS SHALL HAVE PENTIUM SILVER PROCESSOR WITH THE CITY.
3. FIREWALL PROVIDED BY THE CONTRACTOR BUT CONFIGURED BY 2. ETHERNET SWITCH PROVIDED BY THE CITY.
FOR THE MOUSE AND KEYBOARD.
1. SHALL BE IN A WALL MOUNTED CABINET WITH A PULLOUT SHELF 66 kkwarsick
2 1/2"
1/2"
1/4"
90"
72"
X"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
WD31-PLCP-30101
120VAC LPXX-30108, 1Ø, 20AMP
120VAC UPS-LPXX-30108, 1Ø, 20AMP
WD31-PLCP-30101
120VAC LPXX-30108, 1Ø, 20AMP
120VAC UPS-LPXX-30108, 1Ø, 20AMP
PlotDate:06-DEC-20242:48:57PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
TCD
INSTRUMENTATION 13GN02
PCM EXTERNAL ELEVATION
11843A1013GN02.dgn
kkwarsick
1 4
9 8
5 3
2 7
FILE:SCALE:EXTERNAL ELEVATION
NO SCALE
FILE:SCALE:NAMEPLATE DETAIL
NO SCALE
6 10 10
GENERAL NOTES:
5. ALL ENCLOSURES SHALL BE MOUNTED ON A HOUSEKEEPING PAD.
REQUIREMENTS FOR THE APPROPRIATE LOCATIONS.RECOMMENDATIONS. ADHERE TO ALL SEISMIC INSTALLATION
4. SECURE ENCLOSURE TO FLOOR FOLLOWING MANUFACTURER'S 3. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.
SHORT CIRCUIT RATINGS.
2. FOLLOW ALL UL 508 AND 508A SUPPLEMENT SB TO DETERMINE NAME AND ADDRESS MOUNTED ON THE FRONT OF THE ENCLOSURE.
1. PROVIDE LABEL INDICATING INTEGRATOR'S LOGO WITH COMPANY
MAJOR EQUIPMENT SCHEDULE
ITEM DESCRIPTION
1 ENCLOSURE, NEMA 12, FREE STANDING
2 DATA POCKET
3 COOLING FAN
4 EXHAUST GRILLE
5 FOLDING SHELF
6 NAMEPLATE7 MANUFACTURER'S LABEL
8 INDUSTRIAL MONITOR9 KEYBOARD BOX
10 LIGHT W/ INTRUSION SWITCH
11843A1002N601
11843A1002N601
JKR
CAMPUS OAKS ASR WELL
GEB
109
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:47:52PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
TCD
INSTRUMENTATION 13GN03
PCM INTERNAL ELEVATION
11843A1013GN03.dgn
kkwarsick
FILE:SCALE:INTERNAL ELEVATION
NO SCALE
GENERAL NOTES:
1 2 3 4 5 7 9 10 26
32 AS REQUIRED
22 18
ACWIRING
13 12
11 17
14 22 AC WIRING DC WIRING
8 16
ACWIRING
15 19
20 29
24 28
6 22 22 22
25 21
DCWIRING
30 NE314, NE315, NE350, NE351, NE352, NE353, NE354.NE304, NE305, NE306, NE307, NE308, NE310, NE311, NE312, NE313,
13. REFER TO TYPICAL DETAILS NE101, NE102, NE103, NE104, NE105, THE DRAWING OR SPECIFICATIONS.INSTRUMENTS LOCATED OUTDOORS OR OTHERWISE INDICATED IN
12. PROVIDE PANEL SURGE PROTECTION FOR ALL ANALOG/DIGITAL CONSTRUCTION AND WIRING REQUIREMENTS.
11. REFER TO INSTRUMENTATION TYPICAL DETAILS FOR PANEL
CABINET.
10. QUANTITY OF COMPONENTS VARY AS REQUIRED FOR EACH
PENETRATIONS ALLOWED.BOTTOM OF THE ENCLOSURE. NO SIDE, FRONT, OR REAR
9. ALL CONDUIT PENETRATIONS SHALL BE LOCATED AT THE TOP OR THROUGH CONTROL CABINETS.
8. NO CAMERA OR TELEPHONE CABLES SHALL TERMINATE IN OR PASS CONTROL CABINETS.
7. NO 480VAC CIRCUITS SHALL TERMINATE IN OR PASS THROUGH OFF OF BACK PANEL.
6. ELEVATE ALL TERMINAL BLOCK DIN RAIL A MINIMUM OF 2 INCHES TRIMMED FLUSH. INSTALLATION OF ALL NYLON TIE WRAPS SHALL BE TENSIONED AND
5. ALL TIE WRAPS SHALL BE LOCATED OUTSIDE OF THE WIRE DUCTS.
CIRCUIT BREAKER PRIOR TO THE MAIN PANEL CIRCUIT BREAKER.
4. CIRCUIT BREAKERS SHALL BE COORDINATED TO TRIP BRANCH SHORT CIRCUIT RATINGS.
3. FOLLOW ALL UL 508 AND 508A SUPPLEMENT SB TO DETERMINE THE NATIONAL ELECTRIC CODE.CONSTRUCT PANEL TO MEET THE FULL INTENT OF ARTICLE 409 OF
2. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.
NUMBERS.LAYOUT WITH ALL EQUIPMENT, MANUFACTURERS, AND PART TO SUPPLY AS-BUILT DRAWINGS SHOWING FINAL ENCLOSURE
1. ENCLOSURE DRAWING REPRESENTS DESIGN INTENT. CONTRACTOR 23 DC WIRING
23 22 23 23 23
AC WIRING
11843A1002N601
DCWIRING
DCWIRING
ACWIRING
ACWIRING
ACWIRING
22 31
27 33
MAJOR EQUIPMENT SCHEDULE
ITEM DESCRIPTION
1 BACK PANEL
2 PLC BACKPLANE
3 PLC PROCESSOR
4 PLC POWER SUPPLY
5 PLC ETHERNET COMMUNICATION MODULES
6 SIGNAL CONDITIONERS7 PLC DI MODULES
8 PLC DO MODULES9 PLC AI MODULES
10 PLC AO MODULES
11 120VAC PANEL SURGE PROTECTOR
12 CIRCUIT BREAKERS
13 RECEPTACLE, 5A
14 24VDC POWER SUPPLY
15 REDUNDANCY MODULE
16 HVAC CONTROL17 ENCLOSURE TEMPERATURE SWITCH
18 DISCRETE TERMINAL BLOCKS19 ANALOG TERMINAL BLOCKS
20 24VDC FUSED TERMINAL BLOCKS
21 DIN RAIL
22 GRAY WIRE DUCT
23 WHITE WIRE DUCT
24 TIMER / CONTROL RELAYS
25 ETHERNET SWITCH
26 FIBER PATCH PANEL27 ETHERNET SWITCH (PROVIDED BY THE CITY) 28 INTERPOSING RELAYS29 24VDC PANEL SURGE PROTECTOR
30 ELECTRONIC CIRCUIT PROTECTOR
31 FIREWALL (PROVIDED BY THE CITY)
32 GROUND BAR
33 GATEWAY
JKR
CAMPUS OAKS ASR WELL
GEB
110
NL
TEST MONTHLY
SEE INSTRUCTIONS
RESETR
ESET
TESTTE
ST
NO
NC
COM
/G N L L N /G
11 0 31 0
90 70 50
30°F
2 1
11 0 31 0
90 70 50
30°F
2 1
GENERAL NOTES:
KEY NOTES:
REQUIREMENTS.
COMPONENTS TO MEET PROJECT
ONLY. PROVIDE ALL NECESSARY
1. SCHEMATIC ILLUSTRATES DESIGN INTENT
#
10. CITY IT SWITCH.
SPECIFICATIONS.
9. PROVIDE QUANTITY REQUIRED PER
PCM CABINET.
EACH INSTRUMENT POWERED FROM THE
PROVIDE SEPARATE CIRCUIT BREAKERS FOR
8. SIZE BASED ON PROTECTION NEEDS.
MAINTENANCE BYPASS SWITCH.
RECEPTACLE/PLUG AS REQUIRED BY
7. PROVIDE HARDWIRED CONNECTIONS OR
LAPTOP.
SPECIFICATIONS. SIZE RECEPTACLE FOR
6. PROVIDE QUANTITY REQUIRED PER
5. SIZE BASED ON LOAD REQUIREMENT.
NON-OVERLAPPING DOORS.
SWITCHES, WIRED IN SERIES, FOR
OVERLAPPING DOORS. PROVIDE ADDITIONAL
4. INSTALL SWITCH ON OUTERMOST DOOR OF
CIRCUIT IF REQUIRED.CALCULATIONS. PROVIDE ADDITIONAL
3. VERIFY LOADS BASED ON TEMPERATURE
2. SIZE BASED ON PROTECTION NEEDS.
SPECIFICATION REQUIREMENTS.
1. SIZE UPS AND BATTERY BASED ON UPS
RECEPTACLE
GFCI
6 120VAC SURGE PROTECTIVE DEVICE 24VDC SURGE PROTECTIVE DEVICE
TERMINAL BLOCK LEGEND
H N G
BYPASS SWITCH
MAINTENANCE
1 7
LOCATED WITHIN PCM CABINET
UPS & BATTERY
8 2
2 (AS REQUIRED)
I/O POWER
(AS REQUIRED)
INSTRUMENT POWER
2 (AS REQUIRED)
PLC POWER SUPPLY
ULULUL
GGG
NNN
2 UL LOI
G
N
L1 N
GND
+ - SUPPLY
POWER
SWITCHING
24VDC OUT
2 L1 N
GND
+ - SUPPLY
POWER
SWITCHING
IN 1 IN 2 - +
+ - 24VDC OUT
ULUL
GG
NN
+ - WD31-XA2-*
SPD2 FAIL
INPUT
SIG COM
SIG COM
WD31-JS4-*
ACB OK
INPUT
WD31-JS3-*
REDUNDANCY OK
INPUT
SIG COM
WD31-JS2-*
POWER SUPPLY OK
INPUT
SIG COM
WD31-JS1-*
POWER SUPPLY OK
INPUT
SIG COM
WD31-XA1-*
SPD1 FAIL
INPUT
SIG COM
WD31-AUX1-*
ON UPS POWER
INPUT
WD31-XA4-*
ON BATTERY
INPUT
WD31-XA3-*
LOW BATTERY
INPUT
20A-1P
WD31-XA7-*
ECP-C FAIL
INPUT
WD31-XA5-*
ES-C FAIL
INPUT
1 PCM WIRING DIAGRAM
CONTINUED AT UPPER RIGHT
ECP
SIG COM
WD31-XA8-*
ECP-F FAIL
INPUT
(FIELD)
ETHERNET SWITCH
ES-F
SIG COM
WD31-XA6-*
ES-F FAIL
INPUT - G + - CONTINUED AT LOWER LEFT
ECP
SIG COM
WD31-XA10-*
ECP-GW FAIL
INPUT
(WHERE APPLICABLE)
GATEWAY
SIG COM
WD31-XA9-*
GW FAIL
INPUT - G + - (AS REQUIRED) SIGNAL ISOLATORS (AS REQUIRED) INSTRUMENT POWER (AS REQUIRED) PLC I/O MODULES --- +++
NEUTRAL GND
120VAC
LINE
30A-1P
5 H THERMOSTAT N
3 CONDITIONER
CABINET FAN / AIR
9 9
H G
LIGHT
CABINET
9 GG
NN
HH
5A-1P
24VDC OUT
SIG COM
WD31-TSH-*
HIGH CABINET TEMP
INPUT
SWITCH
TEMPERATURE
SIG COM
WD31-ZS-*
INTRUSION
INPUT
DOOR SWITCH
4 ECP
SIG COM
(PROVIDED BY CITY)
ETHERNET SWITCH
ES-C
SIG COM - G + - END CONTROL LADDER LINE HERE (TYP) 24VDC (-) 24VDC (+) UPS 120VAC GROUND NEUTRAL 120VAC PCM GUL+-NH 22 10
TAG LOOP REFERENCE DWG.
30101 WD31-PLCP-30101 13GN11
WD31-PWRA-30101
WD31-PWRB-30101
2 (COMPUTER)
THIN CLIENT
UL
G
N
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:51:52PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
TCD
GEB
13GN04
111
INSTRUMENTATION
CAMPUS OAKS ASR WELL
PCM WIRING DIAGRAM
11843A1013GN04.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
WD31-PLCP-30101 WD31-UPS-30101
PCM UPS
WD31-CB1
30101
TM120VAC-1PWD31-LPXX-30108
WD31-AUX1
30101
DION UPS POWERWD31-PLCX-30101
WD31-XA10
30101
DIECP-GW FAILWD31-PLCX-30101
WD31-PLCP
30101
1 13GN10
WD31-UPS
30101
# KEY NOTES:
3. POWER QUALITY METER IS LOCATED IN THE SWITCHGEAR.
2. E-STOP SWITCH FOR THE EXHAUST FAN IN THE CHEMICAL ROOM.
1. CITY IT SWITCH.
WD37-ZSXA-30793
PUMP ROOM DOOR A
WD37-ZSXA
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXB-30793
PUMP ROOM DOOR B
WD37-ZSXC-30793
CHEM ROOM ROLLUP DOOR
WD37-ZSXD-30793
CHEM ROOM DOOR
WD37-ZSXE-30793
ELECTRICAL ROOM DOOR E
WD37-ZSXF-30793
ELECTRICAL ROOM DOOR F
WD37-ZSXG-30793
PUMP ROOM ROLLUP DOOR G
WD37-ZSXH-30793
PUMP ROOM ROLLUP DOOR H
WD37-ZSXB
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXC
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXD
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXE
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXF
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXG
30793
DIINTRUSIONWD31-PLCX-30101
WD37-ZSXH
30793
DIINTRUSIONWD31-PLCX-30101
WD31-TIXX
30101
AITEMPWD31-PLCX-30101
WD31-ZS2
30101
INTRUSION DR 2
WD31-ZS1
30101
INTRUSION DR 1
WD37-ZSXA
30793
INTRUSION
WD37-ZSXB
30793
INTRUSION
WD37-ZSXC
30793
INTRUSION
WD37-ZSXD
30793
INTRUSION
WD37-ZSXE
30793
INTRUSION
WD37-ZSXF
30793
INTRUSION
WD37-ZSXG
30793
INTRUSION
WD37-ZSXH
30793
INTRUSION
WD31-ZS
30101
DIINTRUSIONWD31-PLCX-30101
WD31-JS1
30101
DIPWR SUP OKWD31-PLCX-30101
WD31-JS2
30101
DIPWR SUP OKWD31-PLCX-30101
WD31-JS3
30101
DIREDUNDANCY OKWD31-PLCX-30101
WD31-JS4
30101
DIACB OKWD31-PLCX-30101
WD31-XA2
30101
DISPD2 FAILWD31-PLCX-30101
WD31-XA1
30101
DISPD1 FAILWD31-PLCX-30101
WD31-XA5
30101
DIES-C FAILWD31-PLCX-30101
WD31-XA6
30101
DIES-F FAILWD31-PLCX-30101
WD31-XA7
30101
DIECP-C FAILWD31-PLCX-30101
WD31-XA8
30101
DIECP-F FAILWD31-PLCX-30101
WD31-XA9
30101
DIGW FAILWD31-PLCX-30101
WD31-XA4
30101
DION BATTERYWD31-PLCX-30101
WD31-XA3
30101
DILOW BATTERYWD31-PLCX-30101
WD31-PQMX
30104
MBTCPWD34-PLCX-30101
PQM_1
3 WD37-HSNX
30302
E-STOPCHEM RM
WD37-HSNX
30302
DIFAN E-STOPWD31-PLCX-30101
2 REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:46PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
TCD
GEB
13GN05
112
INSTRUMENTATION
CAMPUS OAKS ASR WELL
PCM P&ID
11843A1013GN05.dwg
kkwarsick
FLOW_1 MAGNETIC FLOW METER PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK VOLUME FLOW ü ü ü ü FLOW TOTALIZER 1 ü ü ü FLOW TOTALIZER 2 FLOW TOTALIZER 3 RESET TOTALIZER 1 ü ü RESET TOTALIZER 2 RESET TOTALIZER 3 MAINTENANCE REQUIRED ü ü SOFTWARE FAILURE ü MEASUREMENT FAILURE ü ü HARDWARE FAILURE ü COMMUNICATION FAILURE ü MP_1 METERING PUMP PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü OFF ü ü REMOTE ü STOP ü ü START ü ü SPEED ü ü SPEED FEEDBACK ü ü ü DIRECTION OF ROTATION ü ü RUNNING ü ü ü LEAK DETECTED ü ü WRONG SPEED ü ü OVER VOLTAGE ü ü UNDER VOLTAGE ü ü CURRENT ALARM HIGH ü ü TEMPERATURE ALARM HIGH ü ü COMMON ALARM ü ü ü ü PQM_1 POWER QUALITY METER POWER MONITOR M5000 (PM5000) PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK A PH V ü ü ü B PH V ü ü ü C PH V ü ü ü A PH CURRENT ü ü ü B PH CURRENT ü ü ü C PH CURRENT ü ü ü A PH DEMAND CURRENT ü ü B PH DEMAND CURRENT ü ü C PH DEMAND CURRENT ü ü 3 PH AVG DEMAND CURRENT ü ü ü WATTS ü ü ü VARS ü ü ü VA ü ü ü VA DEMAND ü ü ü W DEMAND ü ü ü ENERGY ü ü ü FREQUENCY ü ü AN PH V %THD ü ü BN PH V %THD ü ü CN PH V %THD ü ü A PH CURRENT %THD ü ü B PH CURRENT %THD ü ü C PH CURRENT %THD ü ü AB PH V %THD ü ü BC PH V %THD ü ü CA PH V %THD ü ü POWER FACTOR ü ü ü VFD_1 VFD PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü OFF ü ü REMOTE ü STOP ü ü START ü ü SPEED ü ü SPEED FEEDBACK ü ü ü RESET ELAPSED TIME ü ü RUNNING ü ü ü TOTAL STARTS ü ü DAILY STARTS ü ü ELAPSED TIME ü ü DAILY RUN TIME ü ü A PH V ü ü ü B PH V ü ü ü C PH V ü ü ü A PH CURRENT ü ü ü B PH CURRENT ü ü ü C PH CURRENT ü ü ü AVERAGE 3 PH CURRENT ü ü ü POWER KVA ü ü ü POWER KW ü ü ü POWER FACTOR ü ü ü CURRENT ALARM HIGH ü ü ü OVERLOAD ü ü ü FAULT ü ü ü ü SMART OVERLOAD FAILED ü ü ü FAIL TO RESPOND ü ü ü EQUIPMENT SHUTDOWN ü ü REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 No. 20405 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION PROJECT NO.
LAST SAVED BY: FILE NAME: JKR JW 13GN06 113 INSTRUMENTATION I/O TABLES 11843A1013GN06.dwgkkwarsick P
OWERSOURCE
FIELD
I/O
16" PW
SUPPRESSION SYSTEM
STUBOUT FOR FIRE
4" PW
16" PW
2" PW 2" PW
METER
2" FLOW
PREVENTER
2" BACKFLOW
MM
WD34-FEXX-30113
PRELUBE FLOW SWITCH
7 GPM
0-40 GPM
3/4"PW
S
3/4" PRELUBE
ROTAMETER RANGE 0-30 GPM
10 GPM FOR 5 MIN
PRELUBE ROTAMETER
RANGE 0-25 PSI
PRESSURE REDUCING VALVE
WD34-PIXX-30105
TRICKLE FLOW PRESSURE GAUGE
0-160 PSI
(5 GPM, RANGE 2-10 GPM)
1 WELL VOL CHANGE PER DAY
TRICKLE FLOW
SS
WD34-PIXX-30122
NITROGEN PRESSURE GAUGE
0-600 PSI
WD34-PEXX-30122
NITROGEN PRESSURE ELEMENT
0-600 PSI
3/4" PRELUBE
3/4" TRICKLE
TO ATMOSPHERE
NITROGEN BLEED
CYLINDERS
NITROGEN
WD34-FEXX-30105
ASR WELL PUMP PRELUBE/TRICKLE FLOW ELEMENT
0-25 GPM
TYP
* NF130
NF136
WD34-VALV
30101
WD34-FEXX
30105
MAGNETIC
WD34-FITX
30105
INT
WD34-BKRX
30105
TM120VAC-1PWD31-PLCP-30101
WD34-FIXX
30105
MBTCPFLOW[P&ID Mismatch]
WD34-FEXX
30113
THERMAL
WD34-FUSE
30113
SB120VAC-1PWD31-VFDX-30101
WD34-FSLX
30113
WD34-PEXX
30122
WD34-PIXX FBV
30122
FBV
WD34-PIXX
30105
DISTRIBUTION SYSTEM
1 13N02
PRELUBE
AND HOSE BIBS
VARIOUS EQUIPMENT
0 13N03
DISTRIBUTION
3 13N02
TRICKLE
4 13N02
NITROGEN 2
5 13N02
NITROGEN 1
VENDOR (BASKI) DOWNHOLE
WD34-VCPX-30121
CONTROLLER
FLOW CONTROL VALVE
1/4" NITROGEN1/4" NITROGEN
WD34-FIXX-30103
PROPELLER TURBINE
WD34-FIXX
30103
WD34-SOVX-30124
NITROGEN BLEED SOLENOID VALVE
WD34-SOVX
30124
FBV
WD34-SOVX-30123
NITROGEN SUPPLY SOLENOID VALVE
WD34-SOVX
30123
FBV
WD34-HCOX
30123
DOINFLATEWD31-PLCX-36101
WD34-HCOX
30124
DODEFLATEWD31-PLCX-30101
WD34-PIXX
30122
AIPRESSWD31-PLCX-30101
RANGE IS 0-600 PSI
PANEL PRESSURE
DOWNHOLE CONTROL
WD34-FIXX-30108
PRELUBE ROTAMETER
0-10 GPM
WD34-FIXX
30108
WD34-SOVX-30101
SOLENOID VALVE
WD34-SOVX
30101
80 PSIG
SET TO
TYP
* NF111
TYP
* NP502
40 13N02
WD34-VFDX-30101
38 13N02
WD34-VFDX-30101
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:49:01PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
13N01
114
INSTRUMENTATION
CAMPUS OAKS ASR WELL
WELL PUMP AND VALVES P&ID 1
11843A1013N01.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
1 13N01
PRELUBE
3 13N01
TRICKLE
4 13N01
NITROGEN 2
5 13N01
NITROGEN 1
1/4" NITROGEN
3/4" PRELUBE
3/4" TRICKLE
1/4" NITROGEN
FLOW
TRICKLE
13N05 10
FEED PUMPS
SODIUM FLUORIDE
13N04 9
FEED PUMPS
HYPOCHLORITE
TYP
* NP501
TYP
* NP501
TYP
* NP501
TYP
* NF130
NF136
WD34-FCVX-30120
WELL ANNULUS RECHARGE VALVE
0.5HP 120VAC 1PH
E
D
WD34-BKRX
30120
TM120VAC-1PWD31-LPXX-30108
WD34-FCVX
30120
WD34-HSGX
30120
OSC
WD34-HSAX
30120
LSR
WD34-ZSOC
30120
WD34-FCVX
30120
WD34-ZTX
30120
WD34-DISC
30120
WD34-MOVX
30120
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
30120
DIOPENEDWD31-PLCX-30101
WD34-HSXX
30120
DIREMOTEWD31-PLCX-36101
WD34-ZX
30120
AIPOSITIONWD31-PLCX-30101
WD34-ZCX
30120
AOPOSITIONWD31-PLCX-30101
WD34-MOVX
30130
WD34-MOVX-30130
PUMP COLUMN RECHARGE CONTROL VALVE
0.5HP 120VAC 1PH
E
D
WD34-DISC
30130
WD34-BKRX
30130
TM120VAC-1PWD31-LPXX-30108
WD34-HSGX
30130
OSC
WD34-HSAX
30130
LSR
WD34-ZSOC
30130
WD34-MOVX
30130
WD34-MOVX
30130
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
30130
DIOPENEDWD31-PLCX-30101
WD34-HSXX
30130
DIREMOTEWD31-PLCX-36101
WD34-HCGX
30130
DOCLOSEWD31-PLCX-30101
WD34-HCOX
30130
DOOPENWD31-PLCX-36101
WD34-PSHH
30107
INT
WD34-PITX
30102
INT
WD34-FITX
30104
INT
WD34-BKRX
30104
TM120VAC-1PWD31-PLCP-30101
MM
WD34-PIXX
30102
AIPRESSWD31-PLCX-30101
WD34-PITX
30109
INT
WD34-PIXX
30109
AIPRESSWD31-PLCX-30101
WD34-PUMP-30101
ASR PUMP
450HP 480VAC 3PH
VFD-30101
VFD-RH
480VAC-3P
WD31-MCCX-30100
WD34-TE1X
30101
RTD
WD34-HEAT
30101
WD34-TE2X
30101
RTD
WD34-TE3X
30101
RTD
WD34-PUMP
30101
WD34-VFDX
30101
MBTCPWD31-PLCX-30101
VFD_1
WD34-HSNX
30101
E-STOP
WD34-LCPX
30101
WD34-BKR2
30101
SS480VAC-3PWD31-MCCX-30100
12" AR
12"AS
TESTER
SAND
ROSSUM
WSE
PUMPING
WSE
STATIC
3/4"NAF
3/4"SH
ON SIDE
SPARE TAP
12" AS/AR
6 13N03
STORAGE/RECOVERY
AQUIFER
12"AS
11 13N03
SEWER/DRAIN
TRENCH DRAIN
WD34-LITX
30100
INT
WD34-LIXX
30100
AI LEVELWD31-PLCX-36101
WD34-PEXX-30109
ASR WELL STORAGE PRESSURE TRANSMITTER
0-150 PSIG
WD34-PEXX
30109
PRESSURE
WD34-PEXX-30102
ASR WELL RECOVERY PRESSURE TRANSMITTER
0-160 PSIG
WD34-PEXX
30102
PRESSURE
WD34-PEXX-30107
ASR WELL RECOVERY PRESSURE SWITCH HI HI
@ ~ 125 PSIG
WD34-PEXX
30107
PRESSURE
WD34-PIXX-30102
ASR WELL RECOVERY PRESSURE GAUGE
0-150 PSIG
WD34-PIXX
30102
PRESSURE
WD34-PIXX-30109
ASR WELL STORAGE PRESSURE GAUGE
0-150 PSIG
WD34-PIXX
30109
PRESSURE
WD34-LEXX-30100
ASR WELL LEVEL TRANSDUCER
___-___FT
WD34-LEXX
30100
SUB
VALVE
CONTROL
FLOW
DOWN-HOLE
PUMP BOWLS
VALVE
CHECK
"FOOT"
SCREEN
INLET
# KEY NOTES:
TIME THE LOCATION IS TO BE DETERMINED.
LOCATION; PERHAPS LOCATED ON THE INJECTOR QUILL. AT THIS
MISTY WOOD WELLS THIS VALVE WILL BE PLACES IN ANOTHER
AND SOLAIRE P&IDS HERE. HOWEVER FOR CAMPUS OAKS AND
2. THIS PRESSURE SUSTAINING VALVE IS SHOWN IN THE WESTBROOK
1. CHEMICAL LEAKAGE DRAINS TO THE CHEMICAL DRAIN TRENCH.
FLOOR TRENCH DRAIN
CHEMICAL TRENCH DRAIN
CHEMICAL SUMP
1 1 1
WD34-VALV-30111
DOWN HOLE BASKI VALVE
WD34-VALV
30111
DOWN HOLE BASKI
38 13N01
WD34-FSLX-30105
40 13N01
WD34-SOVX30101
WD34-FIXX
30104
MBTCPWD31-PLCX-30101
FLOW_1
BOTTOM
ON
DRAIN
2 1
00E01
WD34-TE4X
30101
RTDSPARE
WD34-TE5X
30101
RTDSPARE
WD34-TE6X
30101
RTDSPARE
3/4"SEAL
WD34-FEXX-30104
SEAL WATER/PRELUBE FLOW METER
0-3000 GPM
WD34-FEXX
30104
MAGNETIC
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:49:53PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
13N02
115
INSTRUMENTATION
CAMPUS OAKS ASR WELL
WELL PUMP AND VALVES P&ID 2
11843A1013N02.dwg
kkwarsick
TREATMENT, IF REQUIRED
FUTURE WATER
TREATMENT, IF REQUIRED
FUTURE WATER
0 13N01
DISTRIBUTION
6 13N02
STORAGE/RECOVERY
AQUIFER
WD34-FCVX-30150
RECHARGE CONTROL VALVE
0.5HP 120VAC 1PH
E
D
WD34-DISC
30150
WD34-BKRX
30150
TM120VAC-1PWD31-LPXX-30108
WD34-FCVX
30150
MODULATING
WD34-HSGX
30150
OSC
WD34-HSAX
30150
LSR
WD34-ZSOC
30150
WD34-ZTX
30150
POWERSOURCE
FIELD
I/O
WD34-MOVX
30150
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
30150
DIOPENEDWD31-PLCX-30101
WD34-HSXX
30150
DIREMOTEWD31-PLCX-36101
WD34-ZXXX
30150
AIPOSITIONWD31-PLCX-30101
WD34-ZCXX
30150
AOPOSITIONWD31-PLCX-30101
1" PW
12" AS/AR
INSPECTION
CASE FOR VISUAL
FILTER WITH CLEAR
CARTRIDGE POOL
WD34-MOVX
30160
WD34-MOVX-30160
RECOVERY/PRODUCTION VALVE
0.5HP 120VAC 1PH
E
D
WD34-DISC
30160
WD34-BKRX
30160
TM120VAC-1PWD31-LPXX-30108
WD34-HSGX
30160
OSC
WD34-HSAX
30160
LSR
WD34-ZSOC
30160
WD34-MOVX
30160
WD34-MOVX
30160
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
30160
DIOPENEDWD31-PLCX-30101
WD34-HSXX
30160
DIREMOTEWD31-PLCX-36101
WD34-HCGX
30160
DOCLOSEWD31-PLCX-30101
WD34-HCOX
30160
DOOPENWD31-PLCX-36101
12" AR
8" FTW
WD34-MOVX
30140
WD34-MOVX-30140
AQUIFER & WELL FLUSH TO WASTE VALVE
0.5HP 120VAC 1PH
WD34-DISC
30140
WD34-BKRX
30140
TM120VAC-1PWD31-LPXX-30108
WD34-HSGX
30140
OSC
WD34-HSAX
30140
LSR
WD34-ZSOC
30140
WD34-MOVX
30140
E
D
WD34-MOVX
30140
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
30140
DIOPENEDWD31-PLCX-30101
WD34-HSXX
30140
DIREMOTEWD31-PLCX-36101
WD34-HCGX
30140
DOCLOSEWD31-PLCX-30101
WD34-HCOX
30140
DOOPENWD31-PLCX-36101
12 13N04
SEWER/DRAIN
11 13N02
TRENCH DRAIN
TRENCH DRAIN
TABLET BASKET
DECHLORINATION
OFFSITE STORM DRAIN
12" SD
TYP
*
WD34-PIXX-30150 NP501
RECHARGE LINE PRESSURE GAUGE
0-150 PSIG
12" AS
WD34-PDIT
30151
WD34-PIXX
30150
WD34-PDXX
30151
AIPRESS DIFFWD31-PLCX-30101
WD34-FCVX
30150
INSECT SCREEN & AIR GAP
13N03 17
MONITORING WELL
SAMPLE TAP
GRAB
1" SAM
16" PW
TYP
* NP189
FLOOR TRENCH DRAIN
WD34-PEXX-30151
H-STRAINER PRESSURE DIFF ELEMENT
0-5 PSI
WD34-PEXX
30151
PRESS DIFF
12" AS/AR
TYP
* NP501
WD34-PIXX
30106
AIPRESSWD31-PLCX-30101
WD34-PIXX-30106
STORAGE LINE PRESSURE GAUGE
0-160 PSIG
WD34-PIXX
30106
WD34-PEXX-30106
STORAGE LINE PRESSURE ELEMENT
___-___ PSIG
WD34-PEXX
30106
PRESSURE
WD34-PITX
30106
INT
8 13N06
SPARE
1/2" SAM 3
7 13N06
FLUORIDE ANALYZERS
CHLORINE AND
1/2" SAM 2
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:49:05PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
13N03
116
INSTRUMENTATION
CAMPUS OAKS ASR WELL
WELL PUMP AND VALVES P&ID 3
11843A1013N03.dwg
kkwarsick
WD37-FEXX-30001
EMERGENCY SHOWER/EYEWASH FLOW SWITCH
0-20 GPM
POWERSOURCE
FIELD
I/O
12 13N03
CHEMICAL TRENCH DRAIN
BUILDING SERVICE AND HOSE BIBS
VARIOUS EQUIPMENT
WATER HEATER
INSTANT HOT
WD37-HXGR-30401
1"PW
SINK
LABORATORY
3/4"PW
1/2" PW
2" PW
1/2"PW
WATER HEATER (INSIDE CHEMICAL ROOM)
EMERGENCY EYEWASH, SHOWER, AND HOT
15 13N05
DRAIN/SEWER
CHEMD
WD37-PIXX
30001
WD37-FEXX
30001
FBV
WD37-FSXX
30001
DIFLOWWD31-PLCX-30101
WD37-FSHX
30001
13 13N05
CHEMICAL TRENCH DRAIN
9 13N02
ON RECOVERY PIPE
HYPOCHLORITE INJECTION
SODIUM HYPOCHLORITE FEED SKID
WD33-BKRX
30210
TM120VAC-1PWD31-LPXX-30108
WD33-LCPX
30202
FBV
2 1 1
WD33-BKRX
30202
TM120VAC-1PWD31-PLCP-30101
2 WD33-LITX
30201
INT
OUTSIDE BUILDING
3" VENT TO
2" SH
1" SH
3/4" V
3" OF
OVERFLOW
WD33-LIXX
30202
DILEAKWD31-PLCX-30101
WD33-LIXX
30201
AILEVELWD31-PLCX-30101
WD33-PUMP
30210
MBTCPWD31-PLCX-30101
MP_1
MM
3/4" SH
WD33-LEXX-30202
TANK LEAK DETECTION SWITCH
WD33-LEXX
30202
LEAKFBV
WD33-LEXX-30201
SODIUM HYPOCHLORITE STORAGE TANK LEVEL ELEMENT
0-7 FT 1 IN
WD33-LEXX
30201
RADAR
WD33-TANK-30201
SODIUM HYPOCHLORITE TANK
WD33-TANK
30201
WD33-PUMP-30211
HYPOCHLORITE FEED PUMP 1
0.25HP 120VAC 1PH
WD33-PUMP
30211
FBV
WD33-PUMP-30212
HYPOCHLORITE FEED PUMP 2
0.25HP 120VAC 1PH
WD33-PUMP
30212
FBV
4" D
CHEMICAL SUMP
WD33-PLCP
30210
FBV
FLOOR TRENCH DRAIN
WD33-FEXX-30203
FLOW SWITCH
___-___ GPM
WD33-FEXX
30203
FBV
WD33-FITX
30203
FBV
# KEY NOTES:
SKID MOUNTED.
EQUIPMENT WILL BE BY THE VENDOR SINCE THE CONTROL PANEL IS
2. THE WIRING BETWEEN THE VENDOR CONTROL PANEL AND THE
AND THE VENDOR CONTROL PANEL.
MODBUS RTU COMMUNICATION, AND POWER BETWEEN THE PUMP
1. PUMP HAS INTEGRATED CONTROLLER WITH HARDWIRED I/O,
2 WD33-BKRX
30500
TM480VAC-3PWD31-MCCX-30100
TYP
* NL174
TYP
* NF130
NF136
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:51:47PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
13N04
117
INSTRUMENTATION
CAMPUS OAKS ASR WELL
SODIUM HYPOCHLORITE FEED SYSTEM P&ID
11843A1013N04.dwg
kkwarsick
WD33-PUMP-30313
SODIUM FLUORIDE FEED PUMP
0.5HP 120VAC 1PH
WD34-TANK-30311
SATURATOR TANK
WD34-TANK
30311
FBV
WD34-TANK-30312
SOLUTION TANK
WD34-TANK
30312
FBV
10 13N02
INJECTION POINT
SODIUM FLUORIDE
3/4" NAF
VENDOR SUPPLIED SODIUM FLUORIDE SYSTEM
14 13N07
CHEMICAL SUMP
WD34-TANK-30304
BRINE TANK
WD34-TANK
30304
WD34-TANK-30306
WATER SOFTENER TANK 1
WD34-TANK
30306
WD34-TANK-30305
WATER SOFTENER TANK 2
WD34-TANK
30305
# KEY NOTES:
2. CHEMICAL ROOM FLOOR DRAIN.
POWER BETWEEN IT AND THE VENDOR CONTROL PANEL.
1. PUMP HAS INTEGRATED CONTROLLER WITH HARDWIRE I/O AND WD33-BKRX
30310
TM120VAC-1PWD31-LPXX-30108
WD33-LSXX-30310
SODIUM FLUORIDE CONTAINMENT LEVEL SWITCH
S
WD33-SOVX
30311
FBV
WD33-MIXR-30312
SOLUTION TANK MIXER
1 WD33-FQIT-30311
SODIUM FLUORIDE TOTALIZER
WD33-FQIT
30311
WD33-LSXX FBV
30310
FBV
WD33-LSXX-30312
SOLUTION TANK LEVEL SWITCH
WD33-LSXX
30312
FBV
WD33-LCPX
30310
FBV
WATER SOFTENER (INSIDE CHEMICAL ROOM)
3/4" SW
DV
POWERSOURCE
FIELD
I/O
BACKFLOW PREVENTER
BUILDING
3/4" PW
16 13N07
DRAIN/SEWER
13 13N04
CHEMICAL TRENCH DRAIN
15 13N04
FLOOR TRENCH DRAIN
CHEMD
4" D
SEWER
2 SODIUM FLUORIDE (INSIDE CHEMICAL ROOM)
WD33-MIXR
30313
DIRUNNINGWD31-PLCX-30101
WD33-YAXX
30313
DIDIA LEAKWD31-PLCX-30101
WD33-LALX
30312
DITANKWD31-PLCX-30101
WD33-LAXX
30310
DICONTAINMENTWD31-PLCX-30101
WD33-HSNX
30313
DIE-STOPWD31-PLCX-30101
WD33-HSXX
30313
DIREMOTEWD31-PLCX-30101
WD33-SIXX
30313
AISPEED INWD31-PLCX-30101
WD33-SCXX
30313
AOSPEED OUTWD31-PLCX-30101
WD33-HCCX
30313
DO ENABLEWD31-PLCX-30101
WD33-PUMP
30313
DIRUNNINGWD31-PLCX-30101
WD33-YAFX
30313
DIFAILEDWD31-PLCX-30101
WD33-PUMP
30313
FBV WD33-MIXR
30312
FBV
VENDOR SUPPLIED WATER SOFTENER
WD33-FEXX-30313
FLOW SWITCH
___-___ GPM
WD33-FEXX
30313
FBV
WD33-FITX
30313
FBV
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:49:09PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
13N05
118
INSTRUMENTATION
CAMPUS OAKS ASR WELL
LIQUID FLUORIDE FEED SYSTEM P&ID
11843A1013N05.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
WD33-PUMP-30401
MONITORING WELL PUMP 1
1HP 120VAC 1PH
WD33-LITX
30401
INT
WD33-LEXX-30401
COMW-C WELL WATER LEVEL
WD33-LEXX
30401
SUB
WD33-LIXX
30401
AILEVELWD31-PLCX-30101
1"SAM
7 13N03
DISTRIBUTION
SAMPLE FROM
1/2"SAM
pHPROBEpH
PROBE
PANEL
pH CTL
CTL PNL
CI2 RESID
CI2 PROBE
(INSIDE PUMP ROOM)
MONITORING WELL SAMPLE
(INSIDE PUMP ROOM)
CHLORINE ANALYZER
8 13N03
SPARE
1/2"SAM
(INSIDE PUMP ROOM)
FLUORIDE ANALYZER
CTL PNL
PANEL
FLUORIDE
1" SAM
MONITORING WELL
EXISTING MULTIPLE COMPLETION
295 FT BGS)
(WELL DEPTH
COMW-A
415 FT BGS)
(WELL DEPTH
COMW-C
415 FT BGS)
(WELL DEPTH
COMW-B
1"SAM
1" SAM
19 13N07
DRAIN SEWER
AIR-GAP STRUCTURE
PURGE TO STORM DRAIN
WD33-PUMP
30401
WD33-PUMP-30402
MONITORING WELL PUMP 2
1HP 120VAC 1PH
WD33-PUMP
30402
WD33-AITX
30205
CHLORINEFBV
WD33-AEXX-30205
CHLORINE RESIDUAL ANALYZER
___-___ mg/l
WD33-AEXX
30205
CHLORINEFBV
WD33-AITX
30206
pHFBV
WD33-AEXX-30206
pH ANALYZER
___- ___ pH
WD33-AEXX
30206
pHFBV
WD33-AITX
30307
FLUORIDEFBV
WD33-AEXX-30307
FLUORIDE ANALYZER
___-___ mg/l
WD33-AEXX
30307
FLUORIDEFBV
WD33-AIXX
30307
AIFLUORIDEWD31-PLCX-30101
WD33-AIXX
30205
AICHLORINEWD31-PLCX-30101
WD33-AIXX
30206
AIpHWD31-PLCX-30101
WD33-PIXX-30205
CHLORINE ANALYZER PRESSURE GAUGE
0-100 PSI
WD33-PIXX
30205
FBV
WD33-PIXX-30207
FLUORIDE ANALYZER PRESSURE GAUGE
0-100 PSI
WD33-PIXX
30207
FBV
WD33-FIXX-30205
CHLORINE ANALYZER ROTAMETER
0-12 GPH
WD33-FIXX
30205
FBV
WD33-BKRX
30206
TM120VAC-1PWD31-PLCX-30101
WD33-BKRX
30205
TM120VAC-1PWD31-PLCX-30101
WD33-BKRX
30307
TM120VAC-1PWD31-PLCX-30101
1/2" SAM 2 1/2" SAM 21/2" SAM 2
# KEY NOTES:
STAND ALONE.
THE VFDS ARE NOT CONNECTED TO ANY CONTROLLER. THEY ARE
1. EACH MONITORING WELL PUMP IS POWERED BY PORTABLE VFD. 1 1
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:04PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
13N06
119
INSTRUMENTATION
CAMPUS OAKS ASR WELL
WATER QUALITY P&ID
11843A1013N06.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
16 13N05
DRAIN/SEWER
14 13N05
CHEMICAL TRENCH DRAIN
4" D
SINK
RESTROOM
BUILDING SERVICE
2" PW
1/2"PW
HOT
WD37-PIXX-30002
RESTROOM HOT WATER PRESSURE GAUGE
0-60 PSI
TYP
* WD33-LEXX-30209 NL113
CHEMICAL TRENCH DRAIN LEVEL SWITCH
___ FT
AND HOSE BIBS
VARIOUS EQUIPMENT
TOILET
1/2"PW
WD37-HXGR-30002
HEATER
INSTANT HOT WATER 1
/2"PW
SANITARY SEWER
OFFSITE
ROOM AND CHEMICAL ROOM
FLOOR TRENCH DRAINS IN PUMP
CHEMICAL ROOMS
IN PUMP AND
TRENCH DRAINS
CHEMICAL
CHEMICAL ROOM
SUMP AND LEVEL SWITCH IN
RESTROOM
CHEMD
WD33-LSHX
30209
WD33-LEXX
30209
CAPACITANCE
WD37-PIXX
30002
WD33-LSHX
30209
DILEVELWD31-PLCX-30101
43 13N06
FROM TRENCH DRAIN
DRAIN/SEWER
19 13N06
FROM TRENCH DRAIN
DRAIN/SEWER
# KEY NOTES:
WATER HEATER PLUGS INTO A RECEPTACLE.
1. CIRCUIT BREAKER FOR RESTROOM RECEPTACLES. INSTANT HOT WD33-BKRX
30002
TM120VAC-1PWD31-LPXX-30108
1 TYP
* NP502
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:00PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
CGR
GEB
13N07
120
INSTRUMENTATION
CAMPUS OAKS ASR WELL
RESTROOM, DRAIN AND SEWER P&ID
11843A1013N07.dwg
kkwarsick
SECURITY SERVER
CITY C-CURE 9000 DOOR ACCESS/
BARTON RD WTP
THROUGH CITY NETWORK
VPN TUNNELS
IN SCADA DMZ
CONTROLLERS THRU PROXY SERVER
COMMUNICATES WITH EDGE
CITY MANAGED SERVER FW-WTP01
FW-WTP02
SCADA SERVER
SCADA NETWORKSCADA NETWORKSCADA NETWORK
172.17.185.230QOGNIFY VMSVIDEO SERVER
ELECTRICAL ROOM
WD31-PLCP-36101PLC PANEL
WD31-PLCX-36101MODICON M340PLC
WD08-FRWL-36100PA-220RFIREWALL
WD08-NVRX-36300
SSIQ8-R2-8S
VIDEO RECORDER
WD34-VFDX-36101WELL PUMP VFD
40NKS-0000044CCARD READERSGATE AND MAIN DOOR
PUMP ROOM
CHEMICAL ROOM
WD34-FITX-36104
WELL PUMP FLOW METER
WD08-NVRX-36301
SSIQ8-R2-8S
VIDEO RECORDER
PUMP BLDG
WD33-PLCX-36210MODICON M340PLC
S-WATER-WELL13MERAKI MS120-8FPSWITCH
OPTIC HANDHOLEWELLSITE FIBER
PROVIDED BY THE CITY(INCLUDING THE HANDHOLE)PROVIDED BY THE CONTRACTOR WD31-PQMX-36104SWITCHBOARD POWER METER
WD33-PLCP-36210CONTROL PANELSODIUM HYPOCHLORITE
WD08-CKEY-36900
GSTAR004-POE
CARDKEY
WD08-PCXX-30102DELL/WYSE 5070THIN CLIENTWD08-HMIX-36102HIS-ML23-STTDOPERATOR INTERFACE WD08-PCXX-36103DELL/WYSE 5070THIN CLIENTWD08-HMIX-36103HIS-ML23-STTDOPERATOR INTERFACE WD08-CAMX-36304 THRU 36307Q3536-LVE DOME STYLE AXISSECURITY CAMERA WD08-CAMX-36302
Q3536-LVE DOME STYLE AXIS
SECURITY CAMERA
WD08-CAMX-36301
Q3536-LVE DOME STYLE AXIS
SECURITY CAMERA
WD08-CAMX-36303
Q3536-LVE DOME STYLE AXIS
SECURITY CAMERA
WD08-ESWX-36101ARUBA R8N89ASWITCH
(PROVIDED BY OTHERS)WD08-CAMX-36308 & 36309LP READER CAMERA
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:48:03PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
JKR
TCD
INSTRUMENTATION 19GN01
121
11843A1019GN01.dgn
#
GENERAL NOTES:
KEY NOTES:
1 4
4 3
2 5
GEB
CONNECTION DIAGRAM
MISTY WOOD ASR WELL
TERMINATION PANEL.
8. CORNING SPH-01P-DIN IS THE END USER'S PREFERRED
CABLE.
7. CORNING ALTOS IS THE END USER'S PREFERRED FIBER OPTIC 6. NETWORK PROTOCOL IS MODBUS TCP.5. THE NETWORK IS ALL UNDER THE SAME SUBNET.4. THE NETWORK SPEED IS 1GB.3. FIBER OPTIC CABLE SHALL BE SINGLE MODE.2. FIBER OPTIC CONNECTORS SHALL BE LC TYPE.1. ALL ETHERNET CABLE SHALL BE CAT6. kkwarsick
6. RS-485
ALARM RELATED SENSORS FROM PLC PANEL RELAYS.
5. SHALL HAVE A DI CARD AND CONNECT ALL DOOR CONTACTS AND UBUNTU OPERATING SYSTEM.
4. THE THIN CLIENTS SHALL HAVE PENTIUM SILVER PROCESSOR WITH THE CITY.
3. FIREWALL PROVIDED BY THE CONTRACTOR BUT CONFIGURED BY 2. ETHERNET SWITCH PROVIDED BY THE CITY.
FOR THE MOUSE AND KEYBOARD.
1. SHALL BE IN A WALL MOUNTED CABINET WITH A PULLOUT SHELF 66 2
1/2"
1/2"
1/4"
90"
72"
X"
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
WD31-PLCP-36101
120VAC LPXX-36108, 1Ø, 20AMP
120VAC UPS-LPXX-36108, 1Ø, 20AMP
WD31-PLCP-36101
120VAC LPXX-36108, 1Ø, 20AMP
120VAC UPS-LPXX-36108, 1Ø, 20AMP
PlotDate:06-DEC-20242:48:07PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
TCD
INSTRUMENTATION 19GN02
PCM EXTERNAL ELEVATION
11843A1019GN02.dgn
kkwarsick
1 4
9 8
5 3
2 7
FILE:SCALE:EXTERNAL ELEVATION
NO SCALE
FILE:SCALE:NAMEPLATE DETAIL
NO SCALE
6 10 10
GENERAL NOTES:
5. ALL ENCLOSURES SHALL BE MOUNTED ON A HOUSEKEEPING PAD.
REQUIREMENTS FOR THE APPROPRIATE LOCATIONS.RECOMMENDATIONS. ADHERE TO ALL SEISMIC INSTALLATION
4. SECURE ENCLOSURE TO FLOOR FOLLOWING MANUFACTURER'S 3. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.
SHORT CIRCUIT RATINGS.
2. FOLLOW ALL UL 508 AND 508A SUPPLEMENT SB TO DETERMINE NAME AND ADDRESS MOUNTED ON THE FRONT OF THE ENCLOSURE.
1. PROVIDE LABEL INDICATING INTEGRATOR'S LOGO WITH COMPANY
MAJOR EQUIPMENT SCHEDULE
ITEM DESCRIPTION
1 ENCLOSURE, NEMA 12, FREE STANDING
2 DATA POCKET
3 COOLING FAN
4 EXHAUST GRILLE
5 FOLDING SHELF
6 NAMEPLATE7 MANUFACTURER'S LABEL
8 INDUSTRIAL MONITOR9 KEYBOARD BOX
10 LIGHT W/ INTRUSION SWITCH
11843A1002N602
11843A1002N602
JKR
GEB
122
MISTY WOOD ASR WELL
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:47:09PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
TCD
INSTRUMENTATION 19GN03
PCM INTERNAL ELEVATION
11843A1019GN03.dgn
kkwarsick
FILE:SCALE:INTERNAL ELEVATION
NO SCALE
GENERAL NOTES:
1 2 3 4 5 7 9 10 26
32 AS REQUIRED
22 18
ACWIRING
13 12
11 17
14 22 AC WIRING DC WIRING
8 16
ACWIRING
15 19
20 29
24 28
6 22 22 22
25 21
DCWIRING
30 NE314, NE315, NE350, NE351, NE352, NE353, NE354.NE304, NE305, NE306, NE307, NE308, NE310, NE311, NE312, NE313,
13. REFER TO TYPICAL DETAILS NE101, NE102, NE103, NE104, NE105, THE DRAWING OR SPECIFICATIONS.INSTRUMENTS LOCATED OUTDOORS OR OTHERWISE INDICATED IN
12. PROVIDE PANEL SURGE PROTECTION FOR ALL ANALOG/DIGITAL CONSTRUCTION AND WIRING REQUIREMENTS.
11. REFER TO INSTRUMENTATION TYPICAL DETAILS FOR PANEL
CABINET.
10. QUANTITY OF COMPONENTS VARY AS REQUIRED FOR EACH
PENETRATIONS ALLOWED.BOTTOM OF THE ENCLOSURE. NO SIDE, FRONT, OR REAR
9. ALL CONDUIT PENETRATIONS SHALL BE LOCATED AT THE TOP OR THROUGH CONTROL CABINETS.
8. NO CAMERA OR TELEPHONE CABLES SHALL TERMINATE IN OR PASS CONTROL CABINETS.
7. NO 480VAC CIRCUITS SHALL TERMINATE IN OR PASS THROUGH OFF OF BACK PANEL.
6. ELEVATE ALL TERMINAL BLOCK DIN RAIL A MINIMUM OF 2 INCHES TRIMMED FLUSH. INSTALLATION OF ALL NYLON TIE WRAPS SHALL BE TENSIONED AND
5. ALL TIE WRAPS SHALL BE LOCATED OUTSIDE OF THE WIRE DUCTS.
CIRCUIT BREAKER PRIOR TO THE MAIN PANEL CIRCUIT BREAKER.
4. CIRCUIT BREAKERS SHALL BE COORDINATED TO TRIP BRANCH SHORT CIRCUIT RATINGS.
3. FOLLOW ALL UL 508 AND 508A SUPPLEMENT SB TO DETERMINE THE NATIONAL ELECTRIC CODE.CONSTRUCT PANEL TO MEET THE FULL INTENT OF ARTICLE 409 OF
2. REFER TO ELECTRICAL PLANS FOR LOCATION OF ALL ENCLOSURES.
NUMBERS.LAYOUT WITH ALL EQUIPMENT, MANUFACTURERS, AND PART TO SUPPLY AS-BUILT DRAWINGS SHOWING FINAL ENCLOSURE
1. ENCLOSURE DRAWING REPRESENTS DESIGN INTENT. CONTRACTOR 23 DC WIRING
23 22 23 23 23
AC WIRING
11843A1002N602
DCWIRING
DCWIRING
ACWIRING
ACWIRING
ACWIRING
22 31
27 33
MAJOR EQUIPMENT SCHEDULE
ITEM DESCRIPTION
1 BACK PANEL
2 PLC BACKPLANE
3 PLC PROCESSOR
4 PLC POWER SUPPLY
5 PLC ETHERNET COMMUNICATION MODULES
6 SIGNAL CONDITIONERS7 PLC DI MODULES
8 PLC DO MODULES9 PLC AI MODULES
10 PLC AO MODULES
11 120VAC PANEL SURGE PROTECTOR
12 CIRCUIT BREAKERS
13 RECEPTACLE, 5A
14 24VDC POWER SUPPLY
15 REDUNDANCY MODULE
16 HVAC CONTROL17 ENCLOSURE TEMPERATURE SWITCH
18 DISCRETE TERMINAL BLOCKS19 ANALOG TERMINAL BLOCKS
20 24VDC FUSED TERMINAL BLOCKS
21 DIN RAIL
22 GRAY WIRE DUCT
23 WHITE WIRE DUCT
24 TIMER / CONTROL RELAYS
25 ETHERNET SWITCH
26 FIBER PATCH PANEL27 ETHERNET SWITCH (PROVIDED BY THE CITY) 28 INTERPOSING RELAYS29 24VDC PANEL SURGE PROTECTOR
30 ELECTRONIC CIRCUIT PROTECTOR
31 FIREWALL (PROVIDED BY THE CITY)
32 GROUND BAR
33 GATEWAY
JKR
GEB
123
MISTY WOOD ASR WELL
NL
TEST MONTHLY
SEE INSTRUCTIONS
RESETR
ESET
TESTTE
ST
NO
NC
COM
/G N L L N /G
11 0 31 0
90 70 50
30°F
2 1
11 0 31 0
90 70 50
30°F
2 1
GENERAL NOTES:
KEY NOTES:
REQUIREMENTS.
COMPONENTS TO MEET PROJECT
ONLY. PROVIDE ALL NECESSARY
1. SCHEMATIC ILLUSTRATES DESIGN INTENT
#
10. CITY IT SWITCH.
SPECIFICATIONS.
9. PROVIDE QUANTITY REQUIRED PER
PCM CABINET.
EACH INSTRUMENT POWERED FROM THE
PROVIDE SEPARATE CIRCUIT BREAKERS FOR
8. SIZE BASED ON PROTECTION NEEDS.
MAINTENANCE BYPASS SWITCH.
RECEPTACLE/PLUG AS REQUIRED BY
7. PROVIDE HARDWIRED CONNECTIONS OR
LAPTOP.
SPECIFICATIONS. SIZE RECEPTACLE FOR
6. PROVIDE QUANTITY REQUIRED PER
5. SIZE BASED ON LOAD REQUIREMENT.
NON-OVERLAPPING DOORS.
SWITCHES, WIRED IN SERIES, FOR
OVERLAPPING DOORS. PROVIDE ADDITIONAL
4. INSTALL SWITCH ON OUTERMOST DOOR OF
CIRCUIT IF REQUIRED.CALCULATIONS. PROVIDE ADDITIONAL
3. VERIFY LOADS BASED ON TEMPERATURE
2. SIZE BASED ON PROTECTION NEEDS.
SPECIFICATION REQUIREMENTS.
1. SIZE UPS AND BATTERY BASED ON UPS
RECEPTACLE
GFCI
6 120VAC SURGE PROTECTIVE DEVICE 24VDC SURGE PROTECTIVE DEVICE
TERMINAL BLOCK LEGEND
H N G
BYPASS SWITCH
MAINTENANCE
1 7
LOCATED WITHIN PCM CABINET
UPS & BATTERY
8 2
2 (AS REQUIRED)
I/O POWER
(AS REQUIRED)
INSTRUMENT POWER
2 (AS REQUIRED)
PLC POWER SUPPLY
ULULUL
GGG
NNN
2 UL LOI
G
N
L1 N
GND
+ - SUPPLY
POWER
SWITCHING
24VDC OUT
2 L1 N
GND
+ - SUPPLY
POWER
SWITCHING
IN 1 IN 2 - +
+ - 24VDC OUT
ULUL
GG
NN
+ - WD31-XA2-*
SPD2 FAIL
INPUT
SIG COM
SIG COM
WD31-JS4-*
ACB OK
INPUT
WD31-JS3-*
REDUNDANCY OK
INPUT
SIG COM
WD31-JS2-*
POWER SUPPLY OK
INPUT
SIG COM
WD31-JS1-*
POWER SUPPLY OK
INPUT
SIG COM
WD31-XA1-*
SPD1 FAIL
INPUT
SIG COM
WD31-AUX1-*
ON UPS POWER
INPUT
WD31-XA4-*
ON BATTERY
INPUT
WD31-XA3-*
LOW BATTERY
INPUT
20A-1P
WD31-XA7-*
ECP-C FAIL
INPUT
WD31-XA5-*
ES-C FAIL
INPUT
1 PCM WIRING DIAGRAM
CONTINUED AT UPPER RIGHT
ECP
SIG COM
WD31-XA8-*
ECP-F FAIL
INPUT
(FIELD)
ETHERNET SWITCH
ES-F
SIG COM
WD31-XA6-*
ES-F FAIL
INPUT - G + - CONTINUED AT LOWER LEFT
ECP
SIG COM
WD31-XA10-*
ECP-GW FAIL
INPUT
SIG COM
WD31-XA9-*
GW FAIL
INPUT - G + - (AS REQUIRED) SIGNAL ISOLATORS (AS REQUIRED) INSTRUMENT POWER (AS REQUIRED) PLC I/O MODULES --- +++
NEUTRAL GND
120VAC
LINE
30A-1P
5 H THERMOSTAT N
3 CONDITIONER
CABINET FAN / AIR
9 9
H G
LIGHT
CABINET
9 GG
NN
HH
5A-1P
24VDC OUT
SIG COM
WD31-TSH-*
HIGH CABINET TEMP
INPUT
SWITCH
TEMPERATURE
SIG COM
WD31-ZS-*
INTRUSION
INPUT
DOOR SWITCH
4 ECP
SIG COM
(PROVIDED BY CITY)
ETHERNET SWITCH
ES-C
SIG COM - G + - END CONTROL LADDER LINE HERE (TYP) 24VDC (-) 24VDC (+) UPS 120VAC GROUND NEUTRAL 120VAC PCM GUL+-NH 22 10
TAG LOOP REFERENCE DWG.
36101 WD31-PLCP-36101 19GN11
WD31-PWRA-36101
WD31-PWRB-36101
(WHERE APPLICABLE)
GATEWAY
2 (COMPUTER)
THIN CLIENT
UL
G
N
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20243:58:23PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
TCD
GEB
19GN04
124
INSTRUMENTATION
MISTY WOOD ASR WELL
PCM WIRING DIAGRAM
11843A1019GN04.dwg
JKR
kkwarsick
P
OWERSOURCE
FIELD
I/O
WD31-PLCP-36101
WD31-UPS-36101
PCM UPS
WD31-CB1
36101
TM120VAC-1PWD31-LPXX-36108
WD31-AUX1
36101
DION UPS POWERWD31-PLCX-36101
WD31-XA10
36101
DIECP-GW FAILWD31-PLCX-36101
WD31-PLCP
36101
1 13GN10
WD31-UPS
36101
# KEY NOTES:
3. POWER QUALITY METER IS LOCATED IN THE SWITCHGEAR.
2. E-STOP SWITCH FOR THE EXHAUST FAN IN THE CHEMICAL ROOM.
1. CITY IT SWITCH.
WD37-ZSXA-36793
PUMP ROOM DOOR A
WD37-ZSXA
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXB-36793
PUMP ROOM DOOR B
WD37-ZSXC-36793
CHEM ROOM ROLLUP DOOR
WD37-ZSXD-36793
CHEM ROOM DOOR
WD37-ZSXE-36793
ELECTRICAL ROOM DOOR E
WD37-ZSXF-36793
ELECTRICAL ROOM DOOR F
WD37-ZSXG-36793
PUMP ROOM ROLLUP DOOR G
WD37-ZSXH-36793
PUMP ROOM ROLLUP DOOR H
WD37-ZSXB
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXC
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXD
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXE
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXF
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXG
36793
DIINTRUSIONWD31-PLCX-36101
WD37-ZSXH
36793
DIINTRUSIONWD31-PLCX-36101
WD31-TIXX
36101
AITEMPWD31-PLCX-36101
WD31-ZS2
36101
INTRUSION DR 2
WD31-ZS1
36101
INTRUSION DR 1
WD37-ZSXA
36793
INTRUSION
WD37-ZSXB
36793
INTRUSION
WD37-ZSXC
36793
INTRUSION
WD37-ZSXD
36793
INTRUSION
WD37-ZSXE
36793
INTRUSION
WD37-ZSXF
36793
INTRUSION
WD37-ZSXG
36793
INTRUSION
WD37-ZSXH
36793
INTRUSION
WD31-ZS
36101
DIINTRUSIONWD31-PLCX-36101
WD31-JS1
36101
DIPWR SUP OKWD31-PLCX-36101
WD31-JS2
36101
DIPWR SUP OKWD31-PLCX-36101
WD31-JS3
36101
DIREDUNDANCY OKWD31-PLCX-36101
WD31-JS4
36101
DIACB OKWD31-PLCX-36101
WD31-XA2
36101
DISPD2 FAILWD31-PLCX-36101
WD31-XA1
36101
DISPD1 FAILWD31-PLCX-36101
WD31-XA5
36101
DIES-C FAILWD31-PLCX-36101
WD31-XA6
36101
DIES-F FAILWD31-PLCX-36101
WD31-XA7
36101
DIECP-C FAILWD31-PLCX-36101
WD31-XA8
36101
DIECP-F FAILWD31-PLCX-36101
WD31-XA9
36101
DIGW FAILWD31-PLCX-36101
WD31-XA4
36101
DION BATTERYWD31-PLCX-36101
WD31-XA3
36101
DILOW BATTERYWD31-PLCX-36101
3 WD31-PQMX
30104
MBTCPWD34-PLCX-36101
PQM_1
WD37-HSNX
30302
E-STOPCHEM RM
2 WD37-HSNX
30302
DIFAN E-STOPWD31-PLCX-36101
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:49:57PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
TCD
GEB
19GN05
125
INSTRUMENTATION
MISTY WOOD ASR WELL
PCM P&ID
11843A1019GN05.dwg
kkwarsick
FLOW_1 MAGNETIC FLOW METER PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK VOLUME FLOW ü ü ü ü FLOW TOTALIZER 1 ü ü ü FLOW TOTALIZER 2 FLOW TOTALIZER 3 RESET TOTALIZER 1 ü ü RESET TOTALIZER 2 RESET TOTALIZER 3 MAINTENANCE REQUIRED ü ü SOFTWARE FAILURE ü MEASUREMENT FAILURE ü ü HARDWARE FAILURE ü COMMUNICATION FAILURE ü MP_1 METERING PUMP PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü OFF ü ü REMOTE ü STOP ü ü START ü ü SPEED ü ü SPEED FEEDBACK ü ü ü DIRECTION OF ROTATION ü ü RUNNING ü ü ü LEAK DETECTED ü ü WRONG SPEED ü ü OVER VOLTAGE ü ü UNDER VOLTAGE ü ü CURRENT ALARM HIGH ü ü TEMPERATURE ALARM HIGH ü ü COMMON ALARM ü ü ü ü PQM_1 POWER QUALITY METER POWER MONITOR M5000 (PM5000) PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK A PH V ü ü ü B PH V ü ü ü C PH V ü ü ü A PH CURRENT ü ü ü B PH CURRENT ü ü ü C PH CURRENT ü ü ü A PH DEMAND CURRENT ü ü B PH DEMAND CURRENT ü ü C PH DEMAND CURRENT ü ü 3 PH AVG DEMAND CURRENT ü ü ü WATTS ü ü ü VARS ü ü ü VA ü ü ü VA DEMAND ü ü ü W DEMAND ü ü ü ENERGY ü ü ü FREQUENCY ü ü AN PH V %THD ü ü BN PH V %THD ü ü CN PH V %THD ü ü A PH CURRENT %THD ü ü B PH CURRENT %THD ü ü C PH CURRENT %THD ü ü AB PH V %THD ü ü BC PH V %THD ü ü CA PH V %THD ü ü POWER FACTOR ü ü ü VFD_1 VFD PROTOCOL: MODBUS TCP DESCRIPTION CONTROL HISTORIZE INDICATE ALARM TREND INTERLOCK LOCAL ü OFF ü ü REMOTE ü STOP ü ü START ü ü SPEED ü ü SPEED FEEDBACK ü ü ü RESET ELAPSED TIME ü ü RUNNING ü ü ü TOTAL STARTS ü ü DAILY STARTS ü ü ELAPSED TIME ü ü DAILY RUN TIME ü ü A PH V ü ü ü B PH V ü ü ü C PH V ü ü ü A PH CURRENT ü ü ü B PH CURRENT ü ü ü C PH CURRENT ü ü ü AVERAGE 3 PH CURRENT ü ü ü POWER KVA ü ü ü POWER KW ü ü ü POWER FACTOR ü ü ü CURRENT ALARM HIGH ü ü ü OVERLOAD ü ü ü FAULT ü ü ü ü SMART OVERLOAD FAILED ü ü ü FAIL TO RESPOND ü ü ü EQUIPMENT SHUTDOWN ü ü REV DATE BY DESCRIPTION DATE CHECKED DRAWN DESIGNED 11843A.10 JOB NO. DRAWING NO. SHEET NO. SCALES ACCORDINGLY VERIFY SCALES THIS SHEET, ADJUST IF NOT ONE INCH ON BAR IS ONE INCH ON ORIGINAL DRAWING 0 1" OF CITY OF ROSEVILLE 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEF 1 2 3 4 5 6 7 8 9 10 11 12 13 ABCDEFG G ® 178 AQUIFER STORAGE AND RECOVERY WELLS PROJECT DECEMBER 2024 No. 20405 DRAFT FINAL SUBMITTAL NOT FOR CONSTRUCTION PROJECT NO.
LAST SAVED BY: FILE NAME: JKR JW 19GN06 126 INSTRUMENTATION I/O TABLES 11843A1019GN06.dwgkkwarsick P
OWERSOURCE
FIELD
I/O
16" PW
SUPPRESSION SYSTEM
STUBOUT FOR FIRE
4" PW
16" PW
2" PW 2" PW
METER
2" FLOW
PREVENTER
2" BACKFLOW
MM
WD34-FEXX-36113
PRELUBE FLOW SWITCH
7 GPM
0-40 GPM
3/4"PW
S
3/4" PRELUBE
ROTAMETER RANGE 0-30 GPM
10 GPM FOR 5 MIN
PRELUBE ROTAMETER
RANGE 0-25 PSI
PRESSURE REDUCING VALVE
WD34-PIXX-36105
TRICKLE FLOW PRESSURE GAUGE
0-160 PSI
TYPICAL
GLOBE VALVE
ADJ FLOW CTL
(5 GPM, RANGE 2-10 GPM)
1 WELL VOL CHANGE PER DAY
TRICKLE FLOW
SS
WD34-PIXX-36122
NITROGEN PRESSURE GAUGE
0-600 PSI
WD34-PITX-36122
NITROGEN PRESSURE TRANSMITTER
0-600 PSI
3/4" PRELUBE
3/4" TRICKLE
TO ATMOSPHERE
NITROGEN BLEED
CYLINDERS
NITROGEN
WD34-FEXX-36105
ASR WELL PUMP PRELUBE/TRICKLE FLOW ELEMENT
0-25 GPM
TYP
* NF130
NF136
WD34-VALV
36101
WD34-FEXX
36105
MAGNETIC
WD34-FITx
36105
INT
WD34-BKRX
36105
TM120VAC-1PWD31-PLCP-36101
WD34-FIXX
36105
AIFLOWWD31-PLCX-36101
WD34-FEXX
36113
THERMAL
WD34-FUSE
36113
SB120VAC-1PWD31-VFDX-36101
WD34-FSLX
36113
WD34-PITX
36122
WD34-PIXX FBV
36122
FBV
WD34-PIXX
36105
DISTRIBUTION SYSTEM
21 19N02
PRELUBE
AND HOSE BIBS
VARIOUS EQUIPMENT
20 19N03
DISTRIBUTION
23 19N02
TRICKLE
24 19N02
NITROGEN 2
25 19N02
NITROGEN 1
VENDOR (BASKI) DOWNHOLE
WD34-VCPX-30121
CONTROLLER
FLOW CONTROL VALVE
1/4" NITROGEN1/4" NITROGEN
WD34-FIXX-36103
PROPELLER TURBINE
WD34-FIXX
36103
WD34-SOVX-36124
NITROGEN BLEED SOLENOID VALVE
WD34-SOVX
36124
FBV
WD34-SOVX-36123
NITROGEN SUPPLY SOLENOID VALVE
WD34-SOVX
36123
FBV
WD34-PIXX
36122
AIPRESSWD31-PLCX-36101
RANGE IS 0-600 PSI
PANEL PRESSURE
DOWNHOLE CONTROL
WD34-FIXX-36108
PRELUBE ROTAMETER
3-30 GPM
WD34-FIXX
36108
WD34-SOVX-30101
SOLENOID VALVE
WD34-SOVX
30101
WD34-HCOX
36124
DOINFLATEWD31-PLCX-36101
WD34-HCOX
36124
DODEFLATEWD31-PLCX-36101
80 PSIG
SET TO
42 19N02
WD34-VFDX-36101
41 19N02
WD34-VFDX-36101
TYP
* NF111
TYP
* NP502
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:35PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
19N01
127
INSTRUMENTATION
MISTY WOOD ASR WELL
WELL PUMP AND VALVES P&ID 1
11843A1019N01.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
21 19N01
PRELUBE
23 19N01
TRICKLE
24 19N01
NITROGEN 2
25 19N01
NITROGEN 1
1/4" NITROGEN
3/4" PRELUBE
3/4" TRICKLE
1/4" NITROGEN
FLOW
TRICKLE
19N05 30
FEED PUMPS
SODIUM FLUORIDE
19N04 29
FEED PUMPS
HYPOCHLORITE
TYP
* NP501
TYP
* NP501
TYP
* NP501
TYP
* NF130
NF136
WD34-FCVX-36120
WELL ANNULUS RECHARGE VALVE
0.5HP 120VAC 1PH
E
D
WD34-BKRX
36120
TM120VAC-1PWD31-LPXX-36108
WD34-FCVX
36120
WD34-HSGX
36120
OSC
WD34-HSAX
36120
LSR
WD34-ZSOC
36120
WD34-FCVX
36120
WD34-ZTX
36120
WD34-DISC
36120
WD34-MOVX
36120
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
36120
DIOPENEDWD31-PLCX-36101
WD34-HSXX
36120
DIREMOTEWD31-PLCX-36101
WD34-ZX
36120
AIPOSITIONWD31-PLCX-36101
WD34-ZCX
36120
AOPOSITIONWD31-PLCX-36101
WD34-MOVX
36130
WD34-MOVX-36130
PUMP COLUMN RECHARGE CONTROL VALVE
0.5HP 120VAC 1PH
E
D
WD34-DISC
36130
WD34-BKRX
36130
TM120VAC-1PWD31-LPXX-36108
WD34-HSGX
36130
OSC
WD34-HSAX
36130
LSR
WD34-ZSOC
36130
WD34-MOVX
36130
WD34-MOVX
36130
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
36130
DIOPENEDWD31-PLCX-36101
WD34-HSXX
36130
DIREMOTEWD31-PLCX-36101
WD34-HCGX
36130
DOCLOSEWD31-PLCX-36101
WD34-HCOX
36130
DOOPENWD31-PLCX-36101
WD34-PSHH
36107
INT
WD34-PITX
36102
INT
WD34-FITX
36104
INT
WD34-BKRX
36104
TM120VAC-1PWD31-PCMP-36101
MM
WD34-PIXX
36102
AIPRESSWD31-PLCX-36101
WD34-PITX
36109
INT
WD34-PIXX
36109
AIPRESSWD31-PLCX-36101
WD34-PUMP-36101
ASR PUMP
450HP 480VAC 3PH
VFD-36101
VFD-RH
480VAC-3P
WD31-MCCX-36100
WD34-TE1X
36101
RTD
WD34-HEAT
36101
WD34-TE2X
36101
RTD
WD34-TE3X
36101
RTD
WD34-PUMP
36101
WD34-VFDX
36101
MBTCPWD31-PLCX-36101
VFD_1
WD34-HSNX
36101
E-STOP
WD34-LCPX
36101
WD34-BKR2
36101
SS480VAC-3PWD31-MCCX-36100
12" AR
12"AS
TESTER
SAND
ROSSUM
WSE
PUMPING
WSE
STATIC
3/4"NAF
3/4"SH
ON SIDE
SPARE TAP
12" AS/AR
26 19N03
STORAGE/RECOVERY
AQUIFER
12"AS
31 19N03
SEWER/DRAIN
TRENCH DRAIN
WD34-LITX
36100
INT
WD34-LIXX
36100
AILEVELWD31-PLCX-36101
WD34-PEXX-36109
ASR WELL STORAGE PRESSURE ELEMENT
0-150 PSIG
WD34-PEXX
36109
PRESSURE
WD34-PEXX-36102
ASR WELL RECOVERY PRESSURE ELEMENT
0-150 PSIG
WD34-PEXX
36102
PRESSURE
WD34-PEXX-36107
ASR WELL RECOVERY PRESSURE SWITCH HI HI
@ ~ 125 PSIG
WD34-PEXX
36107
PRESSURE
WD34-PIXX-36102
ASR WELL RECOVERY PRESSURE INDICATOR
0-150 PSIG
WD34-PIXX
36102
PRESSURE
WD34-PIXX-36109
ASR WELL STORAGE PRESSURE INDICATOR
0-150 PSIG
WD34-PIXX
36109
PRESSURE
WD34-LEXX-36100
ASR WELL LEVEL TRANSDUCER
___-___FT
WD34-LEXX
36100
SUB
VALVE
CONTROL
FLOW
DOWN-HOLE
PUMP BOWLS
VALVE
CHECK
"FOOT"
SCREEN
INLET
WD34-FEXX-36104
AQUIFER STORAGE/RECOVERY FLOW ELEMENT
0-3000 GPM
WD34-FEXX
36104
MAGNETIC
# KEY NOTES:
TIME THE LOCATION IS TO BE DETERMINED.
LOCATION; PERHAPS LOCATED ON THE INJECTOR QUILL. AT THIS
MISTY WOOD WELLS THIS VALVE WILL BE PLACES IN ANOTHER
AND SOLAIRE P&IDS HERE. HOWEVER FOR CAMPUS OAKS AND
2. THIS PRESSURE SUSTAINING VALVE IS SHOWN IN THE WESTBROOK
1. CHEMICAL LEAKAGE DRAINS TO THE CHEMICAL DRAIN TRENCH.
FLOOR TRENCH DRAIN
CHEMICAL TRENCH DRAIN
CHEMICAL SUMP
1 1 1
WD34-VALV-36111
DOWN HOLE BASKI VALVE
WD34-VALV
36111
DOWN HOLE BASKI
WD34-VFDX
36104
MBTCPWD34-PLCX-36101
FLOW_1
BOTTOM
ON
DRAIN
2 1
00E01
41 19N01
WD34-FSLX-36105
42 19N01
WD34-FSLX-36101
3/4"SEAL
WD34-TE4X
36101
RTDSPARE
WD34-TE5X
36101
RTDSPARE
WD34-TE6X
36101
RTDSPARE
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:53PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
19N02
128
INSTRUMENTATION
MISTY WOOD ASR WELL
WELL PUMP AND VALVES P&ID 2
11843A1019N02.dwg
kkwarsick
TREATMENT, IF REQUIRED
FUTURE WATER
TREATMENT, IF REQUIRED
FUTURE WATER
20 19N01
DISTRIBUTION
26 19N02
STORAGE/RECOVERY
AQUIFER
WD34-FCVX-36150
RECHARGE CONTROL VALVE
0.5HP 120VAC 1PH
E
D
WD34-DISC
36150
WD34-BKRX
36150
TM120VAC-1PWD31-LPXX-36108
WD34-FCVX
36150
MODULATING
WD34-HSGX
36150
OSC
WD34-HSAX
36150
LSR
WD34-ZSOC
36150
WD34-ZTX
36150
POWERSOURCE
FIELD
I/O
WD34-MOVX
36150
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
36150
DIOPENEDWD31-PLCX-36101
WD34-HSXX
36150
DIREMOTEWD31-PLCX-36101
WD34-ZXXX
36150
AIPOSITIONWD31-PLCX-36101
WD34-ZCXX
36150
AOPOSITIONWD31-PLCX-36101
1" PW
12" AS/AR
INSPECTION
CASE FOR VISUAL
FILTER WITH CLEAR
CARTRIDGE POOL
WD34-MOVX
36160
WD34-MOVX-36160
RECOVERY/PRODUCTION VALVE
0.5HP 120VAC 1PH
E
D
WD34-DISC
36160
WD34-BKRX
36160
TM120VAC-1PWD31-LPXX-36108
WD34-HSGX
36160
OSC
WD34-HSAX
36160
LSR
WD34-ZSOC
36160
WD34-MOVX
36160
WD34-MOVX
36160
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
36160
DIOPENEDWD31-PLCX-36101
WD34-HSXX
36160
DIREMOTEWD31-PLCX-36101
WD34-HCGX
36160
DOCLOSEWD31-PLCX-36101
WD34-HCOX
36160
DOOPENWD31-PLCX-36101
12" AR
8" FTW
WD34-MOVX
36140
WD34-MOVX-36140
AQUIFER & WELL FLUSH TO WASTE VALVE
0.5HP 120VAC 1PH
WD34-DISC
36140
WD34-BKRX
36140
TM120VAC-1PWD31-LPXX-36108
WD34-HSGX
36140
OSC
WD34-HSAX
36140
LSR
WD34-ZSOC
36140
WD34-MOVX
36140
E
D
WD34-MOVX
36140
DICLOSEDWD31-PLCX-36101
WD34-ZSOX
36140
DIOPENEDWD31-PLCX-36101
WD34-HSXX
36140
DIREMOTEWD31-PLCX-36101
WD34-HCGX
36140
DOCLOSEWD31-PLCX-36101
WD34-HCOX
36140
DOOPENWD31-PLCX-36101
32 19N04
SEWER/DRAIN
31 19N02
TRENCH DRAIN
TRENCH DRAIN
TABLET BASKET
DECHLORINATION
OFFSITE STORM DRAIN
12" SD
TYP
*
WD34-PIXX-36150 NP501
RECHARGE LINE PRESSURE GAUGE
0-150 PSIG
12" AS
WD34-PDIT
36151
INT
WD34-PIXX
36150
WD34-PDXX
36151
AIPRESS DIFFWD31-PLCX-36101
INSECT SCREEN & AIR GAP
19N03 37
MONITORING WELL
SAMPLE TAP
GRAB
1" SAM
16" PW
TYP
* NP189
FLOOR TRENCH DRAIN
WD34-PEXX-36151
H-STRAINER DIFFERENTIAL PRESSURE TRANSMITTER
0-5 PSI
WD34-PEXX
36151
PRESS DIFF
12" AS/AR
TYP
* NP501
WD34-PIXX
36106
AIPRESSWD31-PLCX-36101
WD34-PIXX-36106
RECHARGE LINE PRESSURE GAUGE
0-160 PSIG
WD34-PIXX
36106
WD34-PEXX-36106
STORAGE LINE PRESSURE ELEMENT
___-___ PSIG
WD34-PEXX
36106
PRESSURE
WD34-PITX
36106
INT
WD34-FCVX
36150
H-STRAINER
8 19N06
SPARE
1/2" SAM 3
7 19N06
FLUORIDE ANALYZERS
CHLORINE AND
1/2" SAM 2
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:49PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
19N03
129
INSTRUMENTATION
MISTY WOOD ASR WELL
WELL PUMP AND VALVES P&ID 3
11843A1019N03.dwg
kkwarsick
WD37-FEXX-36001
FLOW SWITCH
0-20 GPM
POWERSOURCE
FIELD
I/O
32 19N03
CHEMICAL TRENCH DRAIN
BUILDING SERVICE AND HOSE BIBS
VARIOUS EQUIPMENT
WATER HEATER
INSTANT HOT
WD37-HXGR-36401
1"PW
SINK
LABORATORY
3/4"PW
1/2" PW
2" PW
1/2"PW
WATER HEATER (INSIDE CHEMICAL ROOM)
EMERGENCY EYEWASH, SHOWER, AND HOT
35 19N05
DRAIN/SEWER
CHEMD
WD37-PIXX
36001
WD37-FEXX
36001
FBV
WD37-FSXX
36001
DIFLOWWD31-PLCX-36101
WD37-FSHX
36001
33 19N05
CHEMICAL TRENCH DRAIN
29 19N02
ON RECOVERY PIPE
HYPOCHLORITE INJECTION
SODIUM HYPOCHLORITE FEED SKID
WD33-BKRX
36210
TM120VAC-1PWD31-LPXX-36108
WD33-LCPX
36202
FBV
2 1 1
WD33-BKRX
36202
TM120VAC-1PWD31-PLCP-36101
2 WD33-LITX
36201
INT
OUTSIDE BUILDING
3" VENT TO
2" SH
1" SH
3/4" V
3" OF
OVERFLOW
WD33-LIXX
36202
DILEAKWD31-PLCX-36101
WD33-LIXX
36201
AILEVELWD31-PLCX-36101
WD33-PUMP
36210
MBTCPWD31-PLCX-36101
MP_1
MM
3/4" SH
WD33-LEXX-36202
TANK LEAK DETECTION SWITCH
WD33-LEXX
36202
LEAKFBV
WD33-LEXX-36201
SODIUM HYPOCHLORITE TANK LEVEL ELEMENT
0-7 FT 1 IN
WD33-LEXX
36201
RADAR
WD33-TANK-36201
SODIUM HYPOCHLORITE TANK
WD33-TANK
36201
WD33-PUMP-36211
HYPOCHLORITE FEED PUMP 1
0.25HP 120VAC 1PH
WD33-PUMP
36211
FBV
WD33-PUMP-36212
HYPOCHLORITE FEED PUMP 2
0.25HP 120VAC 1PH
WD33-PUMP
36212
FBV
4" D
CHEMICAL SUMP
WD33-PLCP
36210
FBV
FLOOR TRENCH DRAIN
WD33-FEXX-36203
FLOW SWITCH
___-___ GPM
WD33-FEXX
36203
FBV
WD33-FITX
36203
FBVINT
# KEY NOTES:
SKID MOUNTED.
EQUIPMENT WILL BE BY THE VENDOR SINCE THE CONTROL PANEL IS
2. THE WIRING BETWEEN THE VENDOR CONTROL PANEL AND
AND THE VENDOR CONTROL PANEL.
MODBUS RTU COMMUNICATION, AND POWER BETWEEN THE PUMP
1. PUMP HAS INTEGRATED CONTROLLER WITH HARDWIRED I/O,
2 WD33-BKRX
36500
TM480VAC-3PWD31-MCXX-36100
TYP
* NL174
TYP
* NF130
NF136
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:51:56PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
19N04
130
INSTRUMENTATION
MISTY WOOD ASR WELL
SODIUM HYPOCHLORITE FEED SYSTEM P&ID
11843A1019N04.dwg
kkwarsick
WD33-PUMP-36313
SODIUM FLUORIDE FEED PUMP
0.5HP 120VAC 1PH
WD34-TANK-36311
SATURATOR TANK
WD34-TANK
36311
FBV
WD34-TANK-36312
SOLUTION TANK
WD34-TANK
36312
FBV
30 19N02
INJECTION POINT
SODIUM FLUORIDE
3/4" NAF
VENDOR SUPPLIED SODIUM FLUORIDE SYSTEM
34 19N07
CHEMICAL SUMP
WD34-TANK-36304
BRINE TANK
WD34-TANK
36304
WD34-TANK-36306
WATER SOFTENER TANK 1
WD34-TANK
36306
WD34-TANK-36305
WATER SOFTENER TANK 2
WD34-TANK
36305
# KEY NOTES:
2. CHEMICAL ROOM FLOOR DRAIN.
POWER BETWEEN IT AND THE VENDOR CONTROL PANEL.
1. PUMP HAS INTEGRATED CONTROLLER WITH HARDWIRE I/O AND WD33-BKRX
36310
TM120VAC-1PWD31-LPXX-36108
WD33-LSXX-36310
SODIUM FLUORIDE CONTAINMENT LEVEL SWITCH
S
WD33-SOVX
36311
FBV
WD33-MIXR-36312
SOLUTION TANK MIXER
1 WD33-FQIT-36311
SODIUM FLUORIDE FLOW METER
WD33-FQIT
36311
WD33-LSXX FBV
36310
FBV
WD33-LSXX-36312
SOLUTION LEVEL SWITCH
WD33-LSXX
36312
FBV
WD33-LCPX
36310
FBV
WATER SOFTENER (INSIDE CHEMICAL ROOM)
3/4" SW
DV
POWERSOURCE
FIELD
I/O
BACKFLOW PREVENTER
BUILDING
3/4" PW
36 19N07
DRAIN/SEWER
33 19N04
CHEMICAL TRENCH DRAIN
35 19N04
FLOOR TRENCH DRAIN
CHEMD
4" D
SEWER
2 SODIUM FLUORIDE (INSIDE CHEMICAL ROOM)
WD33-MIXR
36313
DIRUNNINGWD31-PLCX-36101
WD33-YAXX
36313
DIDIA LEAKWD31-PLCX-36101
WD33-LALX
36312
DITANKWD31-PLCX-36101
WD33-LAXX
36310
DICONTAINMENTWD31-PLCX-36101
WD33-HSNX
36313
DIE-STOPWD31-PLCX-36101
WD33-HSXX
36313
DIREMOTEWD31-PLCX-36101
WD33-SIXX
36313
AISPEED INWD31-PLCX-36101
WD33-SCXX
36313
AOSPEED OUTWD31-PLCX-36101
WD33-HCCX
36313
DO ENABLEWD31-PLCX-36101
WD33-PUMP
36313
DIRUNNINGWD31-PLCX-36101
WD33-YAFX
36313
DIFAILEDWD31-PLCX-36101
WD33-PUMP
36313
FBV WD33-MIXR
36312
FBV WD33-FITX
36313
FBV
WD33-FEXX
36313
FBV
VENDOR SUPPLIED WATER SOFTENER
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:51:39PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
19N05
131
INSTRUMENTATION
MISTY WOOD ASR WELL
LIQUID FLUORIDE FEED SYSTEM P&ID
11843A1019N05.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
WD33-PUMP-36401
MONITORING WELL PUMP 1
1HP 120VAC 1PH
WD33-LITX
36401
INT
WD33-LEXX-36401
COMW-C WELL WATER LEVEL
WD33-LEXX
36401
SUB
WD33-LIXX
36401
AILEVELWD31-PLCX-36101
1"SAM
7 19N03
DISTRIBUTION
SAMPLE FROM
1/2"SAM
pHPROBE
pHPROBE
PANEL
pH CTL
CTL PNL
CI2 RESID
CI2 PROBE
(INSIDE PUMP ROOM)
MONITORING WELL SAMPLE
(INSIDE PUMP ROOM)
CHLORINE ANALYZER
8 19N03
SPARE
1/2"SAM
(INSIDE PUMP ROOM)
FLUORIDE ANALYZER
CTL PNL
PANEL
FLUORIDE
1" SAM
MONITORING WELL
EXISTING MULTIPLE COMPLETION
1"SAM
1" SAM
39 19N07
DRAIN SEWER
AIR-GAP STRUCTURE
PURGE TO STORM DRAIN
WD33-PUMP
36401
WD33-PUMP-36402
MONITORING WELL PUMP 2
1HP 120VAC 1PH
WD33-PUMP
36402
WD33-AITX
36205
CHLORINEFBV
WD33-AEXX-36205
CHLORINE RESIDUAL ANALYZER
___-___ mg/l
WD33-AEXX
36205
CHLORINEFBV
WD33-AITX
36206
pHFBV
WD33-AEXX-36206
pH ANALYZER
___- ___ pH
WD33-AEXX
36206
pHFBV
WD33-AITX
36307
FLUORIDEFBV
WD33-AEXX-36307
FLUORIDE ANALYZER
___-___ mg/l
WD33-AEXX
36307
FLUORIDEFBV
WD33-AIXX
36307
AIFLUORIDEWD31-PLCX-36101
WD33-AIXX
36205
AICHLORINEWD31-PLCX-36101
WD33-AIXX
36206
AIpHWD31-PLCX-36101
WD33-PIXX-36205
CHLORINE ANALYZER PRESSURE GAUGE
0-100 PSI
WD33-PIXX
36205
FBV
WD33-PIXX-36207
FLUORIDE ANALYZER PRESSURE GAUGE
0-100 PSI
WD33-PIXX
36207
FBV
WD33-FIXX-36205
CHLORINE ANALYZER ROTAMETER
0-12 GPH
WD33-FIXX
36205
FBV
WD33-BKRX
36206
TM120VAC-1PWD31-PLCX-36101
WD33-BKRX
36205
TM120VAC-1PWD31-PLCX-36101
WD33-BKRX
36307
TM120VAC-1PWD31-PLCX-36101
1/2" SAM 2 1/2" SAM 21/2" SAM 2
1 1
295 FT BGS)
(WELL DEPTH
COMW-A
415 FT BGS)
(WELL DEPTH
COMW-C
415 FT BGS)
(WELL DEPTH
COMW-B
# KEY NOTES:
CONTROLLER. THEY ARE STAND ALONE
1. BY PORTABLE VFD. THE VFDS ARE NOT CONNECTED TO ANY
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:51:43PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
KIK
GEB
19N06
132
INSTRUMENTATION
MISTY WOOD ASR WELL
WATER QUALITY P&ID
11843A1019N06.dwg
kkwarsick
P
OWERSOURCE
FIELD
I/O
36 19N05
DRAIN/SEWER
34 19N05
CHEMICAL TRENCH DRAIN
4" D
SINK
RESTROOM
BUILDING SERVICE
2" PW
1/2"PW
HOT
WD37-PIXX-36002
RESTROOM HOT WATER PRESSURE GAUGE
0-60 PSI
TYP
* WD33-LEXX-36209 NL113
CHEMICAL TRENCH DRAIN LEVEL SWITCH
___ FT
AND HOSE BIBS
VARIOUS EQUIPMENT
TOILET
1/2"PW
WD37-HXGR-36002
HEATER
INSTANT HOT WATER 1
/2"PW
ROOM AND CHEMICAL ROOM
FLOOR TRENCH DRAINS IN PUMP
CHEMICAL ROOMS
IN PUMP AND
TRENCH DRAINS
CHEMICAL
CHEMICAL ROOM
SUMP AND LEVEL SWITCH IN
RESTROOM
CHEMD
WD33-LSHX
36209
LEVELREM
WD33-LEXX
36209
CONDUCTIVITY
WD37-PIXX
36002
WD33-LSHX
36209
DILEVELWD31-PLCX-36101
44 19N06
FROM TRENCH DRAIN
DRAIN/SEWER
39 19N06
FROM TRENCH DRAIN
DRAIN/SEWER
# KEY NOTES:
WATER HEATER PLUGS INTO RECEPTACLE.
2. CIRCUIT BREAKER FOR RESTROOM RECEPTACLES. INSTANT HOT COME PRE-ASSEMBLED.
1. THE CONTAINER AND DUPLEX PUMPS ARE VENDOR PROVIDED AND WD31-CBXX
36901
TM208VAC-3POLEWD31-LPXX-36108
WD37-VCPX
36901
FBV
WD37-YAXX
36901
DIFAULTWD31-PLCX-36101
1 SANITARY SEWER
OFFSITE
WD37-PUMP-36902
PROGRESSIVE CAVITY SEWER PUMP 2
WD37-PUMP
36902
FBV
WD37-PUMP-36901
PROGRESSIVE CAVITY SEWER PUMP 1
WD37-PUMP
36901
FBV
WD31-CBKR
36002
TM120VAC 1PH
2 TYP
* NP502
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
No. 20405
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PlotDate:06-DEC-20242:50:56PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1 PROJECT NO. FILE NAME:
JKR
CGR
GEB
19N07
133
INSTRUMENTATION
MISTY WOOD ASR WELL
RESTROOM, DRAIN AND SEWER P&ID
11843A1019N07.dwg
kkwarsick
WIDTH
FRAME
3'-0"FR
AMEHEIGHT
4"
2"
5'-06" TYP "
3'-8"
MAX
3'-0"
3'-6"
12"
BUILT-UP ROOFING SINGLE-PLY ROOFING
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
DOWNSPOUT HANGER1 1/2" x 0.062 AL @ 4'-0" OC
CONC ANCHORS @
INDICATED ON THE WALL MATERIAL AS
CONC OR MASONRYWALLS (TYP)
SPLASH BLOCKWHERE REQD
3" x 4" DOWNSPOUTFORMED FROM 0.032
06/21/19
TYP
AG227
A- A- SECTION
DRAWINGS
PRE-FINISHED AL UNLESS OTHERWISE INDICATED ON THE DRAWINGS.SELECTED FROM STANDARD COLOR OFFERINGS.COLOR SHALL BE ENGINEER
3. COAT AL IN CONTACT WITH CONC AND CMU AS SPECIFIED.2. ALTERNATE SIZE DOWNSPOUTS WILL BE REQUIRED, IF SO INDICATED ON THE DRAWINGS. 1. PROVIDE SPLASH BLOCK AS SHOWN EXCEPT AT PAVING AND SIDEWALKS.NOTE:
DOWN SPOUT - ALUMINUM
2 - 1/4"Ø SST 2" 2"
2"
1"
1'-2" 4"
2'-0"
51/2"
2"
4"
06/21/19
AG229
TYP
2" 2"
2"
1"
1'-2" 4"
2'-0"
51/2"
2"
4"
SPLASH BLOCK - CONCRETE - SURFACE MOUNTED AJ100
06/21/19
TYP
REMOVABLE TRANSOM BAR
GLASS SIDELIGHT
R S T
~
~
LOCATIONS REQUIRED. (TYP)HARDWARE SCHEDULE FORFRAME TYPE. SEE DOOR AND BE TINTED INSULATING GLASS.
4. GLASS AT INTERIOR SIDELIGHTS SHALL BE CLEAR. GLASS AT EXTERIOR SIDELIGHTS SHALL
3. GLASS AT SIDELIGHTS SHALL BE TEMPERED.
LOCATION.
2. SIDELIGHT MAY BE ON EITHER SIDE OF DOOR. SEE DRAWINGS FOR REQUIRED SIDELIGHT
1. SEE DOOR AND HARDWARE SCHEDULE FOR FRAME SIZE, MATERIAL, AND DETAILS.
NOTES:
(TYP)
DOOR - FRAME - STICK
AJ103
06/21/19
TYP
PANEL ONLYTRANSOMREMOVABLE
COILING METAL DOOR
F G N V D
A
C T
(TYP)
6"
6" MIN
6"
6"
10" SQ
10"
10"
2"
~
~
~
~
~
~ ~
GLASS
GLASS
GLASS
GLASS
SHELFDOOR WITHDUTCH
LOCATIONS REQUIRED. (TYP)HARDWARE SCHEDULE FORDOOR TYPE. SEE DOOR AND
ALUM FRAME
~
NOTE 5SEELOUVER.
SCHEDULE.AND HARDWARENOTED ON DOORTRANSOM ASDOOR TYPE BELOW NOTES:1. DOOR SIZE AND TYPE SHALL BE IN ACCORDANCE WITH DOOR AND HARDWARE SCHEDULE.2. GLASS AT DOORS SHALL BE TEMPERED UNLESS OTHERWISE INDICATED ON THE DRAWINGS.3. GLASS AT INTERIOR DOORS SHALL BE CLEAR. GLASS AT EXTERIOR DOORS SHALL BE TINTED.4. PROVIDE WIRE GLASS AT LABELED DOORS.5. LOUVER MAY BE REQD AT ANY DOOR TYPE. IF A LOUVER IS REQUIRED, SIZES AND LOCATIONS WILL BE NOTED ON DOOR AND HARDWARE SCHEDULE.6. PROVIDE LABELED DOORS IN ACCORDANCE WITH DOOR AND HARDWARE SCHEDULE.
DOOR - ELEVATIONS - TYPES
2'-6" x 3'-6"PREFABRICATED
INSULATION
SPRING LATCH
COUNTERROOF HATCH
SELF TAPPINGSCREWS (TYPALL AROUND)
INSULATIONSYSTEM ASSPECIFIED
ROOFINGSPECIFIEDSYSTEM AS
FLASHING
TYP
J 06/21/19
AG170
~
~
ROOF SYSTEM - HATCH
FLASHING
TYP
AG229
PlotDate:13-DEC-20246:08:42PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ARCHITECTURAL 1
11843A1000TA01.dgn
JA
134
TYPICAL DETAILS 00TA01
DFassbinder
5 3/4"
3/4"
3/4"
8"
TYP AT JAMBSWALL TO VENEER,EXTEND CMU TURN AND
SEENOTE2
4"
8"
8"
6" 2"
53/4"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
~ ~
FILL WITH GROUT
DOOR FRAME
DOOR
AND SEALANT BACKER ROD
A- METAL FRAMING B- WOOD FRAMING
C- D- MASONRY CONCRETE
AJ105
06/21/19
TYP
3/4"
3/4"
1/2" MIN
~ ~
CAULK BOTH SIDES
FILL WITH GROUT
CAULK BOTH SIDES
FILL WITH GROUT
HEADER. 2 - 2x MIN.
DOOR FRAME DOOR FRAME
DOOR FRAME DOOR FRAME
WALLTHICKER LINE OF
DOOR DOOR
TO JAMB.DOWN AND FASTEN CLIP LEGS, BEND METAL TRACK.
SHEET 1 OF 2
GYPSUM BOARD GYPSUM BOARD
DOOR - HEAD - DETAILS
E- FURRED MASONRY
AJ107
06/21/19
TYP
SHEET 2 OF 2
5/8"
1 15/16"
DOOR
SIDESCAULK BOTH
AT BLDG INTERIORWALL INSUL SYSTEM
H- RIGID INSUL
JAMB ANCHOR
F- STUCCO
G- METAL BUILDING
SIDESCAULK BOTH
5/8"
PANEL 1 15/16"METAL WALL
WALL FRAMINGMETAL BLDG
2"
STUD OR CONCRETE CONSTRUCTION. FILL FRAMES IN MASONRY WITH GROUT.3. PROVIDE MINIMUM 3 ANCHORS PER JAMB AT MASONRY AND 4 ANCHORS PER JAMB AT OTHERWISE SHOWN OR SCHEDULED.2. PROVIDE 2" FRAME WIDTH, 5 3/4" FRAME DEPTH AND 1/2" BACKBEND TYPICAL UNLESS HARDWARE SCHEDULE.1. DOOR AND FRAME SIZE AND MATERIAL SHALL BE IN ACCORDANCE WITH DOOR AND NOTES:
5/8"
DOOR
SIDESCAULK BOTH
CMUSTUCCO ON
2"
DWGSGYP BD PER
WALL PANELSTRIM TO MATCH
53/4"
7"
MASONRY VENEER
DWGS (TYP)STRUCT REINF PER
MASONRY VENEER
DOOR - JAMB - DETAILS
A- B- C- D- E- AJ109
06/21/19
TYP
CARPET BARRESILIENT
CARPET
STRIP AS REQ'DRESILIENT REDUCER
CONCRETE CERAMIC TILE
PAD AT EXTERIOR.CONC SIDEWALK OR ENTRANCECONT CONC SLAB AT INTERIOR.
WITH ROOM FINISH SCHEDULEFINISH FLOOR MATERIAL IN ACCORDANCE
FINISH SCHEDULEWITH ROOMIN ACCORDANCEOR SHEET VINYLRESILIENT TILE
ROOM FINISH SCHEDULEIN ACCORDANCE WITHFINISH FLOOR MATERIAL
SCHEDULEFINISHWITH ROOMACCORDANCEMATERIAL INFINISH FLOORCONTINUOUS
1. DOOR CLEARANCE AT BOTTOM OF DOOR SHALL BE 1/4" MIN AND 3/8" MAX.
NOTE:
SET THRESHOLD IN SEALANT.HARDWARE SCHEDULE.ACCORDANCE WITH DOOR ANDTHRESHOLD AND DOOR BOTTOM IN
DOOR - SILL - DETAILS
HEADJAMB
SILL
AJ123
06/21/19
TYP
ON THE DRAWINGSLINTEL AS INDICATED
AIR BAFFLE
HOOD
INDICATED ON THE DRAWINGSCONC OR MASONRY WALL AS
FLAT SLAT DOOR CURTAIN
SLOPE FLOOR 1/2" TO EXTERIOR
2"
RECOMMENDATIONS.IN ACCORDANCE WITH MFRSDOOR GUIDE. FASTEN TO WALL
CONT WEATHERSTRIP AT BOTH JAMBS
EXTRUSION AT BOTTOM OF DOORREPLACEABLE NEOPRENE
ON THE DRAWINGS PAVEMENT AS INDICATED
INDICATED ON DRAWINGSWALL INSUL SYSTEM WHERE
SEE NOTE 2
INDICATED ON DRAWINGSWALL INSUL SYSTEM WHERE
2. DIMENSIONS VARY WITH MANUFACTURER, SEE SHOP DWGS FOR ACTUAL SIZE.1. SEE DRAWINGS FOR OPERATOR TYPE AND LOCATION.NOTES:
FIN FL
DOOR - OVERHEAD COILING - MASONRY WALL
E- AJ105
06/21/19
TYP
WALL INSULATION
3/4" ~
FILL WITH GROUT
DOOR FRAME
DOOR
SIDESCAULK BOTH
SHEET 2 OF2
BLDG INTERIORSYSTEM AT WALL INSUL
EXTERIORAT BLDGSTUCCO FIN
F- STUCCO
METAL WALL PANEL
DOOR FRAME
G- METAL BUILDING
DWGSINDICATED ONGYP BD WHERE
H- STEEL LINTEL
RIGID INSULUP WALLFLASHING, 16"WEEP, 24" OCMORTAR NET
WALL FRAMING
MASONRY VENEER
VENEERMASONRY
DOOR - HEAD - DETAILS
4. SEE STRUCT DRAWINGS FOR LINTEL DETAILS.3. SEE SPEC FOR WALL INSULATION SYSTEM DETAILS.2. FRAME DIMENSIONS SHALL MATCH THOSE OF JAMB DETAILS ON AJ107/TYP. HARDWARE SCHEDULE.1. DOOR AND FRAME SIZE AND MATERIAL SHALL BE IN ACCORDANCE WITH DOOR ANDNOTE:
A- B- C- MASONRY METAL FRAMING WOOD FRAMING
AJ107
06/21/19
TYP
GYPSUM BOARD GYPSUM BOARD
JAMB ANCHOR
PER JAMBTWO STUDS
CAULK BOTH SIDES
~
~
SHEET 1 OF 2
5/8" 1 15/16"
5/8" 1 15/16"
3/4"
5/8"
1 15/16"
~~
FILL WITH GROUT
DOOR FRAME
DOOR FRAME
(TYP)
DOOR
DOOR FRAME
D- CONCRETE
PIPE SPACER
CAULK BOTH SIDES
~
FILL WITH GROUT
LINE OF THICKER WALL
3/4"
1 15/16"
5/8"
DOOR FRAME
DOOR
ANCHOR
(COUNTERSUNK NOTE2)
LINE OF THICKER WALL
DOOR - JAMB - DETAILS
PlotDate:13-DEC-20246:09:23PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ARCHITECTURAL 2
11843A1000TA02.dgn
JA
135
TYPICAL DETAILS 00TA02
DFassbinder
M
AX
3'-8"
(TYP)
3'-4"
MIN
2'-5"
MAX
2'-10"
(TYP)
3'-4"
2'-10"
12"3'-6"
1'-6"
OUTLET
@SPOUT
3'-0"MAX
4'-6"
MIN
2'-3"
MAX
4'-0"
MIN
1'-3"
3'-4"
5'-0"MAX5'-0"MAX
8" 1" 8" 1" 7'-4
"
1"
8"
1" 8" 1"
(TYP)
PERELEV
1"
8"
1"
8" 1"
ON THE DWGSAS INDICATED
8"
3'-0"
2'-7"
2'-7"
4'-6"
2'-7"
4'-6" 2'-7"
1'-10" 1'-10" 1'-10"
1'-10" 1'-10"
1'-10"
1'-10" 1'-10"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
WATER CLOSET
URINAL TOWEL DISPENSER
LAVATORY WITH2'-0"x 3'-0" MIRROR
AND RECEPTACLE
AND SHELF
TOILET STALL
URINALSCREEN
ELECTRICWATER EXTINGUISHER
CABINETFIRE
COOLER
ACCESSIBLE
SOAP DISPENSER
INSULATE SUPPLY SIDE OF ENCL
VALVE @ WIDE
GRAB BAR
& DRAIN
AN100
TYP
06/21/19
FIXTURES.
3. A MIN 30"x 48" CLEAR FLOOR SPACE SHALL BE PROVIDED IN FRONT OF ALL ACCESSIBLE AMERICANS WITH DISABILITIES ACT.
2. FIXTURES AND ACCESSORIES AT ACCESSIBLE LOCATIONS SHALL BE COMPLIANT WITH THE
1. SEE DWGS FOR ACCESSIBLE FIXTURE LOCATIONS.
NOTES:
ATACCESSIBLE.
1'-5"TO1'-7"
1'-3".(TYP)
ATACCESSIBLE.
1'-5"MAX
2'-0".(TYP)
7" TO 9"
12"
3'-4"
18"
4'-10"12"
24"
3'-6"
5'-0"x 5'-0" (MIN)
TOILETCOMPARTMENT
1'-6"
BATHROOM - ACCESSORY - MOUNTING
FIRE EXTINGUISHER.SEE SPECIFICATIONSFOR SIZE AND TYPE.
FINISH FLOORELEVATION
WALL
FIRE EXTINGUISHER.SEE SPECIFICATIONSFOR SIZE AND TYPE.
FINISH FLOORELEVATION
WALL
2. SEE SPECIFICATIONS FOR SIGNAGE REQUIREMENTS ABOVE FIRE EXTINGUISHERS.
PARTITION WALL.GROUTED CELL. MOUNT TO STUD WITH LAG BOLTS, OR WOOD SCREWS FOR WOOD CONCRETE ANCHORS FOR MASONRY OR CONCRETE WALLS. AT MASONRY INSTALL AT
1. MOUNT TO WALL WITH NUMBER AND SIZE OF ANCHORS TO MATCH BRACKET. USE NOTES:
AN400
TYP
06/21/19
FIRE EXTINGUISHERWALL-MOUNTED
STYLE F
STYLE C STYLE D
STYLE A STYLE B
KNEE SPACE
APRON
RESILIENT BASE
CLOSURE PANEL
WALL CABINET
RESILIENT BASE (TYP)
RESIN COUNTERTOPMOLDED EPOXY
BASE CABINET
STYLE E
BOX CURB
LINE OF WALL (TYP)
FINISHEDBACKPANEL
PIPE CHASE
LINE OF WALL (TYP)
(TYP)
(TYP)
AP200
TYP
06/21/19
~
~
~
~
MOLDED EPOXY RESIN
COUNTERTOP (TYP)
LABORATORY - METAL - CABINETS
PlotDate:13-DEC-20246:09:26PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1LASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
ARCHITECTURAL 3
11843A1000TA03.dgn
JA
136
TYPICAL DETAILS 00TA03
DFassbinder
3 '-6"
1"
1"
6"
1"
1"
"B"1"'
.25"'
EQUALEQUAL
1'-0"
1'-0"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
CP102
TYP METALLURGICAL EXOTHERMIC WELD
CONNECTION - CABLE TO STRUCTURE
S
2. CABLE SIZE MAY REQUIRE COPPER SLEEVE. SEE MANUFACTURER'S INSTRUCTIONS.
1. REFER TO CP101 FOR EXOTHERMIC WELDING PROCEDURE.
NOTES:
TYP
N
CF161 -B -B PVC PIPE SLEEVE CLASS "C" CONCRETE
4"Ø GALV SCH 40 STEEL POST.
4'-0"
6"
MATERIAL ALL
CONCRETE PAVEMENT
SEE DRAWINGS.
CONCRETE PAVEMENT
WELD ON CAP
PAINT SAFETY YELLOW PERANSI Z535.1. 1/2" BITUMINOUS
FIBER EXP JOINTAROUND (UNLESSOTHERWISE INDICATEDON THE DRAWINGS) -A FINISHED GRADE AC PAVEMENT OR FINISHED GRADEOR AC PAVEMENT.
12/29/2020
GUARD POST - REMOVABLE
CLASS "C" CONCRETE
PER ANSI Z535.1.
1/2"
4'-0"
TYP
N
CF160 GUARD POST
B- -B CONCRETE PAVEMENT
ROUNDED CONCRETE CAP -A FINISHED GRADE AC PAVEMENT OR MATERIAL ALL CONCRETE PAVEMENT 3/8" BITUMINOUS FIBER EXP JOINT AROUND (UNLESS OTHERWISE INDICATED ON THE DRAWINGS) SEE DRAWINGS. FINISHED GRADE OR AC PAVEMENT. AT CONC PAVEMENT SIZE "A" "B" 4" 1'-3" 3'-0" 6" 1'-6" 4'-0"8" 1'-9" 5'-0"
4", 6", OR 8" Ø GALVSCH 40 STEEL POST.PAINT SAFETY YELLOWFILL WITH CONCRETE. 12/24/2020
WELD CAP (IF REQUIRED)
MASTIC
EXOTHERMIC WELD
STRUCTURE
CABLE
CP101
TYP EXOTHERMIC WELDING PROCEDURE
CONNECTION - CABLE TO STRUCTURE
S
TYP
12/04/24
CF200 STEEL SINGLE-LEAF PEDESTRIAN GATE
J
ROLLING GATEVEHICULAR
NOTE 2
STEEL POST
FOOTINGSTEEL POST
NOTE 1
NOTE 3
NOTES:
SELECTED BY OWNER.
4. PAINT ENTIRE GATE ASSEMBLY AFTER FABRICATION USING SYSTEM 300, COLOR DIRECTED BY OWNER. REFER TO SECTION 02820 FOR ADDITIONAL REQUIREMENTS.
3. DOOR HANDLE WITH CARD READER-OPERATED LOCK, LOCATE OUTSIDE GATE AS AS SHOWN IN THE DETAILS.
2. 16 GAUGE PANEL WITH 1/4" DIA HOLES AT 1/2" STAGGER. WELD TO SUPPORTING FRAME SMOOTH ALL SHARP CORNERS.
GATE WIDTH WITH HARDWARE TO PROPERLY FIT IN THE ROUGH OPENING . GRIND
1. HSS2 1/2x2 1/2x3/16 FRAME, MITER CORNERS AND FULLY WELD ALL JOINTS. COORDINATE CP100
TYP CABLE IDENTIFICATION
CORROSION MONITORING & CATHODIC PROTECTION
S
"ANODE 1" AND INCREASE CONSECUTIVELY IN THE DIRECTION OF THE STATIONING.
STRUCTURE STATIONING. IDENTIFY THE ANODE LOCATED AT THE LOWEST STATION AS
3. ANODE NUMBERS ARE BASED ON THE LOCATION OF THE ANODE RELATIVE TO PIPE OR ENTERING TESTING UNITS.
2. CABLE ID REQUIRED FOR ANODES, STRUCTURES, REFERENCES, AND ALL ADDITIONAL CABLES
1. COVER CABLE ID WITH CLEAR HEAT SHRINK TUBING.
NOTES:
RING TERMINAL
OR SOLDERLESS
WIRE LUG (AS
REQUIRED)
CABLE
CABLE IDENTIFICATION
(ANODE # OR STRUCTURE ID)
ANODE #XX
LITERATURE FOR SPECIFIC INSTALLATION INSTRUCTIONS.
NOTE: PROCEDURE IS TO BE USED AS A GENERAL GUIDE ONLY. CONSULT MANUFACTURER'S MORTAR COATING.COATING COMPOUND BEFORE REPAIRINGSTEEL, COVER CONNECTION WITH MASTIC STEP 5B. FOR CONNECTIONS TO MORTAR COATED
WITH MASTIC COATING COMPOUND.COPPER IS COVERED. COAT WELD AREATHERMITE WELD CAP. MAKE CERTAIN ALL
STRUCTURES COVER CONNECTION WITH
STEP 5A. FOR CONNECTION TO METALLIC
PEEN WELD FOR SOUNDNESS.
STEP 4. REMOVE SLAG FROM CONNECTION AND
GUN. FROM OPERATOR AND IGNITE WITH FLINT
STEP 3. HOLD MOLD FIRMLY WITH OPENING AWAY
ATTACH SLEEVE.
STEP 2. STRIP INSULATION FROM WIRE.
(3' X 3') TO BARE SHINY METAL AND CLEAN.
STEP 1. GRIND STRUCTURE CONNECTION AREA
GRAPHITE COVER
HOLD HANDLE
STARTING POWDER
METAL WELDING POWDER
METAL DISC
CABLE
STRUCTURE
GRAPHITE MOLD
SHOWN ON DWGS
WIDTH AS
6'-0" MAX
HEIGHTASSHOWNONDWGS
MIN
1'-0"
AT CONCPAVEMENT
ELEVATION
LANDINGCONCRETE
WALL FOOTING
HINGE (TYP)GATE
PlotDate:13-DEC-20243:07:29PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L137 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
DM
11843A1000TC01.dgn
TYPICAL DETAILS
CIVIL 1
hgarcia
00TC01
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
EPOXY COATED CAST IRON OR STEEL COUPLING
JOINT BOND CABLE
EXOTHERMIC WELD
JOINT BOND CABLE
JOINT BOND CABLE (TYP)
EXOTHERMIC WELD
THIRD JOINT BOND (AS NEEDED)
TYP
CP102
TYP
CP102
10. WAX TAPE FOR BURIED BOLTED FITTINGS PER AWWA C217.
9. BOND WIRES SHALL BE SPACED A MINIMUM OF 6" APART.
FLEXIBLE PORTIONS OF FLEXIBLE JOINTS SHALL BE PROVIDED WIT HAN ADDITIONAL 24" OF EXCESS CABLE.
8. BOND CABLES SHALL BE INSTALLED WITH ALLOWANCE FOR FULL ALLOWABLE JOINT MOVEMENT. BOND CABLES ACROSS
7. NUMBER OF BOND CABLES PER JOINT AS SPECIFIED.
INSTALLATION INSTRUCTIONS.
6. EXOTHERMIC WELDING OF BOND CABLE TO PIPE SHALL BE DONE ACCORDING TO CP101, CP102, AND MANUFACTURER IRON PIPE IN SOIL.
5. ALL CABLE CONNECTIONS SHALL BE MADE BY EXOTHERMIC WELDING OR PIN BRAZING, EXCEPT CABLE CONNECTIONS ON CAST
4. DO NOT BOND ACROSS ANY INSULATING FLANGES, COUPLING, OR UNIONS.
3. INSULATED STRANDED COPPER BOND CABLES SHALL BE SIZED ACCORDING TO THE SPECIFICATION.
2. CLEAN PIPE PRIOR TO WELDING.
1. TYPICAL FOR NON-WELDED PIPING OR WELDED PIPING WITH MECHANICAL COUPLINGS.
NOTES:
CP150
TYP
CONTINUITY BONDING FOR NON-WELDEDMETALLIC PIPE AND MECHANICAL FITTINGS J
TEE
FLEX COUPLING WITH RESTRAINER
FLANGED-JOINT (NON-ISOLATING)
PUSH-ON JOINT
(MULTIPLE COMPONENT)
FLEXIBLE COUPLING/ MECHANICAL SLEEVE
INSULATED COUPLING
PIPE SECTION VIEW
CROSS
60° 60°
120°
ADAPTER/SLEEVE
VALVE CROSSING
VALVE
pipe
Non-metallic
pipe
Non-metallic
pipe
Metallic
ISOLATED APPURTENANCE
FLANGE-FLANGE
NON-METALLIC TO METALLIC
BLIND FLANGE
DISMANTLING JOINT WITH VALVE
FLEXIBLE JOINT
BEND
BELL & SPIGOT
VICTAULIC COUPLING
JOINT BOND CABLE
INSULATING BOOT
NEW/PROJECT PIPE ISOLATED/EXISTING PIPE
WASHER
JOINT BOND CABLE (TYP)
12/04/24
WELD (TYP)EXOTHERMIC
WELD (TYP)EXOTHERMIC TYP
CP102
WELD (TYP)EXOTHERMIC
PlotDate:13-DEC-20243:04:29PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L138 ASTSAVEDBY:
PROJECT NO. FILE NAME:
hgarcia CE
CE
DM
11843A1000TC02.dgn
TYPICAL DETAILS
CIVIL 2
00TC02
8.25"'
1.215"'
18"'
2'min.'
2.5''
GRADE
TEST STATION
SUPPORT POST
SPECIFICATION)
ELECTRODE CABLES (AS REQUIRED PER
ANODE, STRUCTURE, AND REFERENCE
FOOTER
CONCRETE
CABLES
SLACK IN
ANODEDIST.FROMPIPE'
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
PHENOLIC DIELECTRIC ISOLATING
WASHER (G-10 GLASS)
POROUS ION PLUG
REFERENCE ELECTRODE CABLE
SSTL STEEL WASHER
SSTL ALL-THREADED
BOLT
CP175 ISOLATION JOINT FLANGE KIT DETAILS
TYP
J
DIELECTRIC ISOLATING
GASKET, TYPE E G-10
WITH O-RING EPDM
DIP PIPE SSTL PIPE OR DIP PIPE
SSTL FLANGE BOLT
FULL LENGTH MYLAR DIELECTRIC
ISOLATING SLEEVE (G-10 GLASS)
SSTL FLANGE NUT
STEEL WASHERS AT BOTH SIDES OF FLANGE BOLT.
ISOLATING WASHERS SHALL BE INSTALLED SANDWICHED BETWEEN A PAIR OF MATCHING WASHER ON EITHER SIDE OF FLANGE BOLT. FOR PIPE DIAMETERS GREATER THAN 36",
5. FOR NOMINAL PIPE DIAMETERS UP TO 36", PROVIDE ONE ISOLATING AND ONE STEEL
4. DO NOT INCLUDE ISOLATION WASHER FROM STAINLESS STEEL SIDE OF FLANGE.
3. ISOLATION IS TO BE TESTED AFTER INSTALLATION.
2. FULL LENGTH ISOLATING SLEEVES REQUIRED FOR ALL THRU-FLANGE BOLTS OR STUDS.
1. TYPICAL FOR NON-WELDED PIPING OR WELDED PIPING WITH MECHANICAL COUPLINGS.
NOTES:
CP201
TYP
BURIED OR IMMERSED REFERENCE ELECTRODE
S
BURIAL OR IMMERSION.
2. REMOVE PROTECTIVE END CAP FROM POROUS ION PLUG WITHIN 24 HOURS PRIOR TO BASED ON ELECTROLYTE.
1. REFERENCE ELECTRODE SHALL BE DESIGNED FOR PERMANENT BURIAL OR IMMERSION, NOTES:
CP303
TYP ABOVE GROUND
TEST STATION MOUNTING - PE SUPPORT POST
S
TO STRUCTURE
REQUIRED, REFER TO CP306.
2. IF ABOVE GROUND TEST STATION IS NOT ALLOWED AND A TRAFFIC RATED TEST STATION IS FREEZE/THAW DEPTH REQUIREMENTS.
1. EXTEND DEPTH OF CONCRETE FOOTER TO MIN REQUIRED FOR CLIMATES WITH HIGHER NOTES:
CP322
TYP WITHOUT TEST STATION
DIRECT CONNECT ANODE TO PIPE
S
5. ANODE MAY BE PLACED BESIDE OR BELOW PIPE, PER SPECIFICATION REQUIREMENTS..
BACKFILL TO 6" ABOVE ANODE WITH THE NATIVE SOIL.
4. ANODE TO BE INSTALLED IN NATIVE SOIL ALONG WITH CLOTH BAG OF ANODE BACKFILL.
3. REFER TO THE SPECIFICATIONS FOR CABLE SIZES AND COLOR.
2. TYPE, NUMBER, AND PLACEMENT OF ANODES PER SPECIFICATION REQUIREMENTS.
1. PROVIDE SLACK IN CABLES TO ALLOW FOR STRUCTURE SETTLEMENT AND MOVEMENT.
NOTES:
CP306
TYP
AT GRADE TRAFFIC RATED TEST STATION
S
CONDITIONS (I.E. MOUNTAIN REGIONS, COLD NORTHERN CLIMATES).
7. CONCRETE PAD SHALL BE RATED TO 4500 PSI IN CLIMATES WITH FREEZE/THAW FREEZE/THAW DEPTH REQUIREMENTS.
6. EXTEND DEPTH OF CONCRETE PAD TO MIN REQUIRED FOR CLIMATES WITH HIGHER TEST BOX.
5. PROVIDE ENOUGH SLOPE AWAY FROM TEST STATION TO PROVIDE DRAINAGE AWAY FROM PAD.
4. WRAP ENTIRE TEST BOX BODY WITH POLYETHYLENE TAPE PRIOR TO CASTING CONCRETE INSTALL TEST STATION IN TRAFFIC LANES OR PARKING STALLS.
3. TEST BOX TO BE FIELD LOCATED +/- 5' FROM STATIONING GIVEN ON DRAWINGS. DO NOT TEST BOX.
2. BOTTOM OF TEST BOX SHALL BE NATIVE SOIL. DO NOT PLACE ROCK, SAND, OR GRAVEL IN SERVICE BOX.
1. PROVIDE 18" SLACK IN CABLES TO ALLOW TEST BOARD TO BE LIFTED 2' OUT OF THE FLUSH NOTES:
6. REFER TO CP100 FOR CABLE LABEL INSTRUCTIONS.
5. REFER TO THE SPECIFICATIONS FOR CABLE SIZES AND COLOR.
4. REFERENCE ELECTRODE AND COUPON (IF REQUIRED) NOT SHOWN, FOR CLARITY.
3. TYPE, NUMBER, AND PLACEMENT OF ANODES PER SPECIFICATION REQUIREMENTS.
2. ROUTE ALL WIRES THROUGH RIGID PVC UNDERGROUND AND GRS ABOVE GROUND TO TEST STATION.
1. PROVIDE 18" SLACK IN CABLES TO ALLOW FOR STRUCTURE SETTLEMENT AND MOVEMENT.
NOTES:
CP311 CATHODIC PROTECTION TEST STATION
TYP
R 12/11/24
SSTL PIPE SIDE SSTL PIPE SIDE
SSTL WASHER
SSTL HEX NUT
PIPE
FLANGE KIT
SIDE VIEW ISOLATION JOINT
FLANGE KIT
TOP VIEW ISOLATION JOINT
REFERENCE CELL BODY
(COPPER/COPPER SULFATE)
EXOTHERMIC WELD (TYP) CP102
TO STRUCTURE
TEST BOARD
MARKED "CP TEST STATION"
CAST IRON TRAFFIC COVER.
6"MIN
3"
18"
SPECIFICATION)
ELECTRODE CABLES (AS REQUIRED PER
ANODE, STRUCTURE, AND REFERENCE
TERMINAL BOARD LAYOUT
TEST STATION
CATHODIC PROTECTION
TO TEST STATION
EXOTHERMIC WELD (TYP)
STRUCTURE
CABLES
0.01 Ω SHUNT
GALVANIC
ANODE CABLE
TERMINAL
ASSEMBLY
PERMANENT REFERENCEELECTRODE CABLE
(IF REQUIRED)
TYP
CP102
TYP
CP327
FULL FACE ISOLATING
GASKET, TYPE E G-10
G-10 ISOLATING WASHER
G-10 ISOLATING SLEEVE
STRUCTURE
CABLE
STRUCTURE
GALVANIC
ANODE (TYP) GALVANIC ANODE CABLE
NOTE:
REFERENCE ELECTRODE DETAILS.
DETAIL CP328/TYP FOR COUPON AND NOT SHOWN FOR CLARITY. REFER TO
COUPON AND REFERENCE ELECTRODES
ANODE (TYP)
PIPE
ANODE CABLE
WELD CAP
TYP
2" DIA. x 3' LONG PVC CONDUIT
IS GREATERWHICHEVER 1" OR 2% SLOPE,
REBAR (TYP)
No. 4
CONCRETE PAD
2' x 2' 4000 PSI
STEEL BODY (AASHTO H-20)
TRAFFIC RATED TEST BOX, 18"
PlotDate:13-DEC-20243:07:23PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L139 ASTSAVEDBY:
PROJECT NO. FILE NAME:
hgarcia CE
CE
DM
11843A1000TC03.dgn
TYPICAL DETAILS
CIVIL 3
00TC03
4 "
MIN
8"
MIN
6"
MIN
8 1/2"
MIN6"
1" 6"
MIN
6"
MIN6"
2'-0"
MIN
8"
2'-0"
3'-0"
7"
3"CLR
6"MIN
MIN
8"
NUT (TYP)
BRASS HEX
(TYP)
BRASS WASHER
TEST BOARD
CAP SCREW
HEAD SLOTTED
BRASS ROUND
"BURNDY" OR EQUAL
TYPE CONNECTOR
CABLE WITH CRIMP
WASHER
BRASS LOCK
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
1 2
8. TEST BOARD LAYOUT FOR COUPON AND REFERENCE ELECTRODE IS IN ADDITION TO REGULAR TEST BOARD LAYOUT.
INSTALLER AS THE PIPELINE IS PADDED AND BACKFILLED BY PROVIDING MEANS TO LEAN THE TEST STATION AGAINST THE TRENCH WALL.
7. ROUTE ALL CABLES IN APPROPRIATELY SIZED CONDUIT BETWEEN THE PIPE AND THE TEST STATION BASE. THE CONDUIT WILL ALSO AID THE SAME MATERIAL AS THE PIPE AT THE LOCATION OF INSTALLATION.
6. INSTALL REFERENCE ELECTRODES AND COUPONS IN NATIVE SOILS AND PLACE 6" FROM EDGE OF THE PIPE. COUPONS SHALL CONSIST OF THE
5. REFERENCE ELECTRODE IS STAND ALONE.
STRUCTURE CABLE.
4. COUPON (PROTECTED) ALWAYS CONNECTED TO STRUCTURE CABLE VIA A SWITCH DEVICE. UNPROTECTED COUPON NOT CONNECTED TO
3. TWO COUPONS WITH COUPON HOLDER INCLUDED AT EACH LOCATION. ONE CALLED NATIVE COUPON, THE OTHER CALLED CP COUPON.
2. ANODES CONNECTED TO STRUCTURE CABLES VIA SHUNTS. ONE ANODE PER TERMINAL.
1. TEST STATIONS CAN BE PURCHASED WITH UP TO 11 TERMINALS.
GENERAL NOTES:
METALLIC COUPON
PVC CONDUIT TO
TEST STATION
PIPELINE
EXOTHERMIC WELD (TYP)
COUPON CABLE
STRUCTURE CABLE (TYP)
6"
REFERENCEELECTRODE
REFERENCE ELECTRODE CABLE
4"
REFERENCE ELECTRODE
PIPELINE
METALLIC COUPON
(SAME MATERIAL AS PIPE)
STRUCTURE CABLE
(TYP)
COUPON CABLES
REFERENCE
ELECTRODE
CABLE
PLANE CONTROL JOINTS.(SEE NOTE 4)
(SEE NOTE 5)
1 2
MIN 6" ABC
3/4" RADIUS (TYPBOTH SIDES)
2 - #4
SECTION
1/2" DEEP WEAKENED
DEPRESSED CURB
6"
3"
3"
PAVEMENT SECTION
1"
DRAWINGS
INDICATED ON THE
6" UNLESS OTHERWISE
AC PAVING
SEE DRAWINGS FOR
1'-4"MIN
WHERE INDICATED ON THE DRAWINGS.
5. DEPRESS CURB AT DRIVEWAYS, ROADWAYS, SIDEWALKS FOR HANDICAPPED ACCESS, AND FACES, PROVIDE 1/2" RADIUSED EDGE EACH SIDE AT JOINTS.
4. PROVIDE WEAKENED PLANE JOINTS AT 10 FEET OC MAXIMUM. AT FRONT, TOP AND BACK
3. DO NOT PASS REINFORCING BARS THROUGH EXPANSION JOINTS.
EXPANSI0N JOINT MATERIAL.
WIDE WITH 1/4" RADIUS CONCRETE EDGES AT BOTH SIDES OF JOINT. USE BITUMINOUS FIBER STRUCTURES, AND AT MAXIMUM SPACING OF 30 FEET. EXPANSION JOINTS SHALL BE 3/4"
CURVATURE, AT BOTH SIDES OF DRIVEWAYS AND WALKWAYS, AT CURB RETURNS, AT
2. PROVIDE 3/4" EXPANSION JOINTS AT ENDS OF CONCRETE PLACEMENT, AT POINTS OF
1. FINISH CURB ON TOP, 8" DOWN FRONT FACE, AND 2" DOWN BACK.
NOTES:
UNDER CURB
TYP
CR100
A- 12/29/2020 YARD CURB
3/4" R (TYP
AC PAVING
1/2" R
BOTH SIDES)
6 "
SECTION
1'-5"
1"
1"
DRAWINGS
ON THE
INDICATED
OTHERWISE
6" UNLESS
(4) #4
SECTIONPAVEMENTFORDRAWINGSSEE
CURB AND GUTTER6" MIN. ABC UNDER
WHERE INDICATED ON THE DRAWINGS.
5. DEPRESS CURB AT DRIVEWAYS, ROADWAYS, SIDEWALKS FOR HANDICAPPED ACCESS, AND FACES, PROVIDE 1/2" RADIUSED EDGE EACH SIDE AT JOINTS.
4. PROVIDE WEAKENED PLANE JOINTS AT 10 FEET OC MAXIMUM. AT FRONT, TOP AND BACK
3. DO NOT PASS REINFORCING BARS THROUGH EXPANSION JOINTS.
EXPANSI0N JOINT MATERIAL.
WIDE WITH 1/4" RADIUS CONCRETE EDGES AT BOTH SIDES OF JOINT. USE BITUMINOUS FIBER STRUCTURES, AND AT MAXIMUM SPACING OF 30 FEET. EXPANSION JOINTS SHALL BE 3/4"
CURVATURE, AT BOTH SIDES OF DRIVEWAYS AND WALKWAYS, AT CURB RETURNS, AT
2. PROVIDE 3/4" EXPANSION JOINTS AT ENDS OF CONCRETE PLACEMENT, AT POINTS OF BACK.
1. FINISH CURB ON TOP, DOWN FRONT FACE AND ACROSS GUTTER TO PAVING, AND 2" DOWN NOTES:
TOOLED EDGE1/4" RADIUS (SEE NOTE 4)
JOINTS.PLANE CONTROL (SEE NOTE 5)CURBDEPRESSED1/2" DEEP, WEAKENED #4@12"
TYP
CR102 YARD CURB AND GUTTER
A- 12/24/2020 STAKES @ 6'-0" OC
COMPACTED ABCAC PAVING
FINISH GRADE
1/2"
5/8"Ø x 1'-6" STEEL GRADE
SEE NOTE 1.HEADER BOARDS.SMALLER RADIUS, USE 2 - 1 x 8 EDGES AND LARGE RADIUS. FOR 2 x 8 HEADER BOARD AT STRAIGHT NOTES:
1. HEADER BOARD MATERIAL SHALL BE EITHER PRESSURE TREATED DOUGLAS FIR OR REDWOOD.
TYP
CR106
12/29/2020
YARD CURB - WOOD HEADER
TYP
CR110
A-B- 3 - #4 #4 @ 12"
#4 @ 12"
4 - #4
SECTION - VALLEY GUTTERSECTION - CROSS GUTTER
1"
3"CLR
71/4"
1 1/4"
AC PAVING
SECTIONFOR PAVEMENTSEE DRAWINGS
SECTIONFOR PAVEMENTSEE DRAWINGS
AC PAVING
TOOLED EDGE1/4" RADIUS
TOOLED EDGE1/4" RADIUS
UNDER GUTTER6" MIN ABC
UNDER GUTTER6" MIN ABC
FACES, PROVIDE 1/2" RADIUSED EDGE EACH SIDE AT JOINTS.
3. PROVIDE WEAKENED PLANE JOINTS AT 10 FEET OC MAXIMUM. AT FRONT, TOP AND BACK
2. DO NOT PASS REINFORCING BARS THROUGH EXPANSION JOINTS.
USE BITUMINOUS FIBER EXPANSI0N JOINT MATERIAL.
JOINTS SHALL BE 3/4" WIDE WITH 1/4" RADIUS CONCRETE EDGES AT BOTH SIDES OF JOINT.
CURVATURE, AT INTERSECTIONS, AND AT MAXIMUM SPACING OF 30 FEET. EXPANSION
1. PROVIDE 3/4" EXPANSION JOINTS AT ENDS OF CONCRETE PLACEMENT, AT POINTS OF NOTES:
GUTTER - CROSS AND VALLEY
12/29/2020
CP327
TYP
TEST BOARD TERMINAL ASSEMBLY
J 11/14/24
SIDE VIEW
COUPON AND REFERENCE ELECTRODE INSTALLATION
S
TYP
CP328
TOP VIEW
TO TEST STATION
REFERENCE
ELECTRODE
CABLE
NATIVE
COUPONCABLE
MAGNETIC
SWITCH
PROTECTED
COUPON CABLE
STRUCTURE
CABLE
ELECTRODE
REFERENCE
COUPON AND
PlotDate:13-DEC-20243:11:09PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L140 ASTSAVEDBY:
PROJECT NO. FILE NAME:
hgarcia CE
CE
DM
11843A1000TC04.dgn
TYPICAL DETAILS
CIVIL 4
00TC04
OD OF MANHOLE + 12"
10"
3" MIN
WIDTH
SIDEWALK
WIDTH
SIDEWALK
SEEDRAWINGS(6'-0"MIN)
PADWIDTH
MIN
1'-4"
SEE DRAWINGS (4'-0" MIN)
PAD LENGTH
MIN
12"
"W"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
SEE NOTE 2JOINT.EXPANSION
SEE DWGSFINISHED GRADE, PAVEMENT OR
ABC (TYP)MIN 6" COMPACTED
0"
4"
SEE DWGSFINISHED GRADE, PAVEMENT OR
SEE NOTE 1JOINT.EXPANSION
WIDTH
FOR SIDEWALK
SEE NOTE 1JOINT.EXPANSION
(TYP)
8"
1 1/2
SECTION
1 7"
#5 (TYP AROUND)
MIN
6"
DOORCOILING
UNO
1"
W/ FIN FL UNOT.O. RAMP FLUSH
D SECTION
1 MIN 6" COMPACTED ABC
SEE NOTE 1.SIDEWALK.AT END OF EXP JT.SURFACE)(HORIZ BREAKERBOND C
1 MAX
SLOPE
SEE DRAWINGS
DOORWIDTH+4'-0"
1:10 1:10
SLOPE
2'-0"
2'-0"
TYP
CR306
C C
A- PLAN
SLOPE
MAX -B PLAN
MIN
DOORWIDTH
2 2'-0"
MIN
DOORCOILING
SIDEWALK AT STRUCTURES
RAMP
2 SIM
2'-0"
D
2 SIDEWALK
AT RAMP W/ ADJACENT
SEE DRAWINGSRAMP LENGTH
MINMIN
RAMPWIDTH
DOORCOILING
RAMPWIDTH
SEE DWGSFIN FL
TYP
CR310
COILING DOORSIDEWALK - AT STRUCTURES - RAMP AT
R SHEET 2 OF 2 11/14/2024
TYP
CR310
COILING DOORSIDEWALK - AT STRUCTURES - RAMP AT
SHEET 1 OF 2 12/24/2020
JOINT SEALANTSIDEWALK/PAVEMENT
1/4" MIN"W" /2
GAPMAX 3/8"MIN 1/4"
BACKER ROD
JOINT MATERIALRUBBER EXPANSIONSYNTHETIC SPONGE
1/4" RADIUS (TYP)
CUT OUT TOP OF RCPOR VCP WITHIN MANHOLE3" EPOXY GROUTSEE NOTE 2 (TYP) CLASS "A"
48" FOR 6" THRU 12"
PIPES.
60" FOR 15" THRU 48"
PIPES.
#5 @ 12" EW
STEEL TROWELFINISH
SOIL BACKFILLEXISTING PAVEMENTTOP OF MH SHALL MATCHAC PAVEMENT OR
CONCRETE
INDICATED ON THEUNLESS OTHERWISE
MORTAR 6" TO EXISTING GRADE
DRAWINGS
BASE WHERE SOIL ISOR 8" MIN ABC UNDERUNDISTURBED SOILCAST BASE AGAINSTUNSTABLE.CAST-IN-PLACECONE SHOWN ROTATED 90°.
TYP
N
8" (TYP)
12" MIN
6" MIN. 1'-6" MAX.
6" CLR
CS110 MANHOLE
30" CI MH FRAME AND COVER.
~
3" MIN
ASREQD
CLASS "A" CONCRETE BASE.PRECAST CONCRETE MANHOLEECCENTRIC PRECAST CONCRETEGRADE RINGS AS REQUIRED 2'-6"TO3'-0"
RISERS WITH VARIABLE HEIGHT
MANUFACTURER'S DETAIL.
3. FORM GROOVE IN MANHOLE BASE WITH STEEL OR ALUMINUM BASE RING PER 2. SEAL JOINTS WITH PRECAST CONCRETE JOINT SEALANT.
GROUT.
1. LOCATE MANHOLE COVER ON DOWNSTREAM SIDE OF MANHOLE. SET MANHOLE FRAME IN NOTES:
SEE NOTE 3SEE NOTE 1.
12/24/2020
JOINTS AT ENDS OF SIDEWALK. JOINT 3/8" WIDE, AND AS INDICATED IN DETAIL E ON SHEET 2.
2. EXPANSION JOINT AT FACE OF STRUCTURE. CONTINUE JOINT TO PERPENDICULAR EXPANSION INDICATED IN DETAIL E ON SHEET 2
1. EXPANSION JOINT AT END OF SIDEWALK CONCRETE PLACEMENT. JOINT 3/4" WIDE, AND AS NOTES:
SEE DWGSFINISHED GRADE.PAVEMENT OR
SEE DWGSFIN FL
MIN
#4@8 EW
12"
STRUCTURE. SEE NOTE 2EXPANSION JOINT AT FACE OF
MIN 4" EMBEDDETAIL SC040/TYP DOWELS. SET PER SST OILED SMOOTH 1/2" DIA TYPE 304 3"CLR
2"
12"
(TYP)
1"UNO
6" 8"
MIN
10" 6"
1 2
1 1 1/2
MIN
1 1 1/2
AROUND)#5 (TYP
MIN
2"CLR
RAMP WIDTH
MIN
TYP
CR302 SIDEWALK
C- C- B- A- N 1/4" RADIUS ALL SLOPE EDGES (TYP) PLAN TYPICAL SECTION SECTION AT CURBS 1" (TYP) 4" UNO 1/4"/FT UNO B- SIDEWALK MATCH JOINTS IN JOINTS IN CURB: SEE NOTE 1. JOINTS. EXPANSION SEE NOTE 1. JOINTS. EXPANSION FINISHED GRADE SLOPE: SEE DWGS NOTE 3. JOINTS. SEE CONTROL TOOLED SEE NOTE 2. JOINT. EXPANSION 4. TOP OF CONCRETE ELEVATIONS: AS INDICATED ON THE DRAWINGS. CONCRETE EDGES EACH SIDE AT JOINTS. SIDEWALK WIDTH, BUT NOT GREATER THAN 10 FEET OC MAXIMUM. PROVIDE 1/4" RADIUS 3. PROVIDE WEAKENED PLANE JOINTS AT UNIFORM SPACING EQUAL TO 1.0 TO 1.25 TIMES RADIUS CONCRETE EDGE AT SIDEWALK. 2. PROVIDE EXPANSION JOINT AT CURB. JOINT SHALL BE 3/8" WIDE BITUMINOUS FIBER WITH 1/4" WITH 1/4" RADIUS CONCRETE EDGES AT EACH SIDE. MAXIMUM SPACING OF 30 FEET. EXPANSION JOINTS SHALL BE 3/4" WIDE BITUMINOUS FIBER AT BOTH SIDES OF DRIVEWAYS, AT INTERSECTIONS, AT CORNERS OF STRUCTURES, AND AT 1. PROVIDE EXPANSION JOINTS AT ENDS OF CONCRETE PLACEMENT, AT POINTS OF CURVATURE, NOTES: (4'-0"UNO) (4'-0"UNO) 12/24/2020 R
CR314
TYP
SIDEWALK - ENTRANCE PAD
1. EXPANSION JOINT AT FACE OF STRUCTURE: 3/8" WIDE AND AS INDICATED IN DETAIL 1.NOTES:
11/14/2024 - TYP EACH SIDE OF DOOR SLOPE 1/4"/FTUNO
B
A PLAN
(TYP 3 SIDES)THICKENED EDGE -1 DETAIL 1/4" RADIUS
~
#4@12" EW
#4 x
FIN FL UNOFLUSH W/ T.O. PAD
(TYP ALL EDGES)
6" 8"
MIN (TYP)
EXT DOOR
THRESHOLD
ABC (TYP)COMPACTED MIN 6"
SC040/TYP MIN 4" EMBED.DOWELS. SET PER DETAIL SST OILED SMOOTH 1/2" DIA x 1'-8" TYPE 304 -B SECTION ON DWGS (7" MAX)OTHERWISE SHOWN 4" UNLESS
NOTE 1 & DETAIL 1EXPANSION JOINT. SEE
CENTERED6 x 6 - W1.4 x W1.4WELDED WIRE FABRIC
SEE NOTE 2EXPANSION JOINT
DRAWINGSINDICATED ON THE AND GUTTER AS CURB OR CURB
ON THE DRAWINGSGUTTER AS INDICATED CURB OR CURB AND
COMPACTED ABC
COMPACTED ABC MIN 6" MIN 6"
B- SLOPE
TYP
CR306
C- N 07/26/21
SLOPE
SECTION AT CURBS
1/4"/FT UNO
SIDEWALK - AT STRUCTURES
C- A- PLAN SEE NOTE 1. JOINTS. EXPANSION B- 1/4"/FT UNO 1" (TYP) B- SEE NOTE 4. OF STRUCTURE. JOINTS AT FACE EXPANSION IN SIDEWALK MATCH JOINTS JOINTS IN CURB: SEE NOTE 4 SEE NOTE 2. JOINT. EXPANSION SEE NOTE 3. CONTROL JOINTS. TOOLED SEE DWGS FIN FL
TYPICAL SECTION
SEE DWGSFIN FL
5. TOP OF CONCRETE ELEVATIONS: AS INDICATED ON THE DRAWINGS.
SIDEWALKS. JOINTS SHALL BE 3/8" WIDE BITUMINOUS FIBER.
4. PROVIDE EXPANSION JOINT AT FACE OF STRUCTURE. CONTINUE JOINTS THROUGH ADJACENT CONCRETE EDGE EACH SIDE AT JOINTS. SIDEWALK WIDTH, BUT NOT GREATER THAN 10 FEET OC MAXIMUM. PROVIDE 1/4" RADIUS
3. PROVIDE WEAKENED PLANE JOINTS AT UNIFORM SPACING EQUAL TO 1.0 TO 1.25 TIMES RADIUS CONCRETE EDGE AT SIDEWALK.
2. PROVIDE EXPANSION JOINT AT CURB. JOINT SHALL BE 3/8" WIDE BITUMINOUS FIBER WITH 1/4" WITH 1/4" RADIUS CONCRETE EDGES AT EACH SIDE.MAXIMUM SPACING OF 30 FEET. EXPANSION JOINTS SHALL BE 3/4" WIDE BITUMINOUS FIBER AT BOTH SIDES OF DRIVEWAYS, AT INTERSECTIONS, AT CORNERS OF STRUCTURES, AND AT
1. PROVIDE EXPANSION JOINTS AT ENDS OF CONCRETE PLACEMENT, AT POINTS OF CURVATURE, NOTES:
SEE NOTE 2EXPANSION JOINT
WALLCONC
ON THE DRAWINGSGUTTER AS INDICATED CURB OR CURB AND
SEE NOTE 4
THE DRAWINGSINDICATED ON WHERE AS AND GUTTER CURB OR CURB 6 x 6 - W1.4 x W1.4 CTRWELDED WIRE FABRIC
DETAIL
1 E
JOINT SEALANT
(TYP) SIDEWALK/PAVEMENT 1/4" RADIUSBACKER ROD
JOINT MATERIALRUBBER EXPANSIONSYNTHETIC SPONGE
GAPMAX 3/8"MIN 1/4"
1/4" MIN"W" /2
EDGES (TYP)1/4" RADIUS ALL
4" UNO
COMPACTED ABCMIN 6"
4" UNO
6" 0"
2" CLR
3" CLRMIN
MIN
2"CLR
PlotDate:13-DEC-20243:10:06PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L141 ASTSAVEDBY:
PROJECT NO. FILE NAME:
hgarcia CE
CE
DM
11843A1000TC05.dgn
TYPICAL DETAILS
CIVIL 5
00TC05
1 0"
ASREQD
VARIES10"
2'-6" SQ 8"
12"
WIDTH OF TRENCH
ALONG PIPE
LARGEST OD
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
SECTION
1. TYPE OF PIPE AND TYPE OF PIPE JOINT OR COUPLER AS INDICATED ON THE DRAWINGS.NOTE:
TYP
CY119
R
PIPE ENCASEMENT - CONCRETE
11/14/2024
TYP
SR609
FROM VERTICAL
STEEL H-20 GRATING
(TYP)
AND REBATE
FABRICATE ROD ANCHORATTACHMENT AT 30º
BEDDING -B PIPE FOUNDATION
TRENCH WIDTH -A
PIPE FOUNDATION
PIPE SPRINGLINE
TRENCH WIDTH
PIPE SPRINGLINE PIPEOD
PIPEOD
CL
CL
(ABOVE SPRINGLINE)BEDDING
(BELOW SPRINGLINE)HAUNCH ZONE
EMBEDMENT ZONEPIPEEMBEDMENT ZONEPIPE
PIPE ZONE EMBEDMENT - RIGID PIPE
PIPE ZONE EMBEDMENT - FLEXIBLE PIPE
TYP
SN
CY111
SHEET 2 OF 2
PIPE TRENCH
08/19/22
MORTAR
AC PAVEMENT ORTOP OF MH SHALL MATCH
REINFORCED
GRADE RINGS
FLOW
60" FOR 15"
48" FOR 6"
THRU 48" PIPES.
THRU 12" PIPES.
6" TO EXISTING GRADEUNLESS OTHERWISEINDICATED ON THE DWGS
SOIL BACKFILLEXISTING PAVEMENT
MANHOLE RISERSW/ VARIABLE HEIGHT
CAST-IN-PLACE CLASS "A"AGAINST UNDISTURBED SOILOR 8" MIN ABC UNDER BASEWHERE SOIL IS UNSTABLE.
FORM GROOVE INMANHOLE BASE W/STEEL OR ALUMINUMBASE RING PER MFRSDETAILOR VCP WITHIN MANHOLECUT OUT TOP OF RCP TYP
N
CS116
FINISHSTEEL TROWEL 3" EPOXY GROUT
12" MIN
12"
MIN
6" MIN. 1'-6" MAX.
8" (TYP)
SEE NOTE 1 (TYP)
30" CI MH FRAME AND COVER
6" CLR
OD OF MANHOLE + 12"
#5 @ 12" EW
CLASS "A" CONCRETE
CONCRETE FLAT TOPPRECAST CONCRETE
AS REQUIRED
CONCRETE BASE. CAST BASE
1. SEAL JOINTS WITH PRECAST CONCRETE JOINT SEALANT.NOTE:
12/29/2020
MANHOLE - MINIMUM COVER CONDITION
PAVEMENT
MH WALL THICKNESSAND MATERIAL VARIES
SUBGRADE
THICKNESS AS REQUIRED. WHEN THICKNESS IS LESS THAN 1/2",
PLAN -A
A- TYP CS124 GRADE PLANT MIX MATERIAL CLASS "A" CONCRETE ALL AROUND FRAME SECTION USE MORTAR. WHEN THICKNESSIS GREATER THAN 2", USE BRICK. 1" MAX.1/2" MIN.
8"
4"
AND SEAL WITH 3/8" FINE DENSE LEAVE CONCRETE COLLAR LOW FOUR 2" x 4" STEEL SPACERS WITH
12/29/2020
MANHOLE - GRADE ADJUSTMENT
SLOPE1/4"/FT
#4 @ 8" EW T & B
OR AS INDICATED
ON THE DRAWINGS
6" ABC
TYP
R
CS202
4"
#4 @ 8" EWCENTERED (TYP)
CATCH BASIN
SEEDRAWINGS
6" (TYP ALL AROUND)
SHEET 1 OF 2
CLASS "C" CONCRETE FILLHOT-DIP GALVANIZE
11/14/2024 SHEET 2 OF 2
TYP
CS202 CATCH BASIN
R
COORDINATE ASCATCH BASIN
TYP
(TYP)
TYP
INDICATED ON
SD382 1/2" (TYP)
CL
CL
THE DRAWINGS
LOW POINT (TYP)VALLEY GUTTER FLOW LINE,
TYPE 2 - CATCH BASIN AT VALLEY GUTTER
CR110
TRENCH WIDTH
AS SPECIFIED
SAW CUT
EXISTING GRADE
EXISTING SUBGRADE
UNDISTURBED SOIL
SHOULDERBEGINNING OFPAVEMENT, ORFACE, EDGE OFEXIST GUTTER
TAPECAUTIONARY MARKER
PAVEMENT SECTION
(SEE DRAWINGS)NEW PAVEMENT
(SEE DRAWINGS)SUBGRADENEW PAVEMENT
AND IN OPEN AREAS
OUTSIDE ROADWAY
AND PAVED AREAS
IN ROADWAYS
BACKFILL
PIPE FOUNDATION
ZONEEMBEDMENTPIPESHEET 2SEE DETAILS,
ON THE DRAWINGSELEVATION INDICATEDGRADE / GRADE TOMATCH EXISTING
BEDDING
P STABILIZATION FABRIC IPEOD
AREAPAVEMENT IN THISAND REPLACETHAN 3'-0", REMOVEVARIES. IF LESS SEE NOTE 2SLOPE
SEE NOTE 1SHORING
3. SEE SPECIFICATIONS FOR DEPTH AND WIDTH REQUIREMENTS.2. SEE SPECIFICATIONS FOR SLOPE REQUIREMENTS.1. SEE SPECIFICATIONS FOR SHORING REQUIREMENTS.NOTES:
TYP
SN
CY111 PIPE TRENCH
SHEET 1 OF 2 08/19/22
11/14/24
(4) #5 CONTINUOUS FORPIPE 36" ID AND SMALLER(4) #6 CONTINUOUS FORPIPE LARGER THAN 36" ID PIPE CLASS "A" CONCRETE
8" MIN (TYP)
(TYP ALL AROUND)
3" CLR
SPECIFIEDON THE DRAWINGS ORPIPE JOINT AS INDICATED
BOTTOM OF PIPE)
6" MIN (TYP TOP &
#4@2'-0"
PlotDate:13-DEC-20243:05:55PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L142 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
11843A1000TC06.dgn
TYPICAL DETAILS
CIVIL 6
00TC06
hgarcia
DM
2 '-6"UNLESSINDICATED
12"
12" SQ
4'-0"
2'-0"
6"
1/2"SLOPE
3" (TYP)
3"CLR
BELOW SLAB6" DRAIN ROCK
6"MIN
TRENCH
6" MINIMUM (TYP) "X" + 4" MIN
"X"
"L"/2
"L"/2
9" MIN
0.25 Ø
8" MIN
6"MIN
4'-0"
VARIES
18"
24"
No. 63626
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
FINISH GRADE "C" CONCRETE SLAB
1 CUBIC FOOT OFDRAIN ROCK
OTHERWISEONDRAWINGS
AL PL 1/4" x 3/4" x 4" (TYP)
1/2" RADIUS (TYP)SEE SIGNAGE SPECIFICATIONSAFETY WARNING SIGN 1'-6" SQUARE CLASS
(2) #4 EW
RISER BELOW GRADETAPE WRAP HYDRANT
INDICATED ON THE DRAWINGSUNLESS OTHERWISE 1" NON-FREEZE HOSE BIBB U-BOLTS1/4" Ø HOT-DIP GALV
4. INSTALL HOSE RACK PER DETAIL MA417/TYP AT EACH HOSE BIBB.
EASY READING.
3. SIGN AS SHOWN IS ROTATED 90° OFF TRUE POSITION. SIGN SHALL BE MOUNTED TO PERMIT 2. SIGN SHALL BE 7" x 10" AND SHALL CONFORM TO THE SPECIFICATIONS.1. SIGN SHALL BE 3/8" THICK PLASTIC RESISTANT TO SUNLIGHT (ULTRAVIOLET) DETERIORATION.NOTES:
TYP
SN
CY722 FREEZELESS HOSE BIBB
12/18/2023
4. VALVE TYPE AS INDICATED ON THE DRAWINGS.
3. CLEAN VALVE BOX OF ALL DEBRIS AND SOIL.
2. COAT BURIED PIPE AND VALVE BOX AS SPECIFIED.
ROTATION TO OPEN VALVE.
SQUARE AWWA NUT WITHIN 36" OF VALVE BOX COVER. NUT IS TO INDICATE DIRECTION OF
1. ALL BURIED VALVES SHALL BE PROVIDED WITH EXTENSION STEM OPERATION WITH 2" NOTES:
3 SQ FT x 8" CLASS A CONC PAD
WIDTH
PLAN
UNDISTURBED SOIL
SECTION
DIA = VALVE BOX ID MINUS 1/8"
VALVE STEM EXTENSION
VALVE SUPPORT
VALVE ENDS FOR TYPEOF PIPE INSTALLED
CLASS "C" CONCRETE
1/4" THICK STL TRASH RING. RING
RUBBER VALVE BOX TOP HAT
PAVED UNPAVED
CENTERED
#5@12" EW
SERVICE STAMPED ON LID
BEDDING
BOTTOM OF TRENCH
BEDDING
PAVEMENT
TYP
10/20/20
CY716
S
GATE VALVE - DIRECT BURY
UNDISTURBED SOILOBTAIN BEARING AREA AGAINSTLENGTH "L" AS REQUIRED TO
SLOPEMAXIMUM
2 1
TOOBTAINBEARINGAREA
ADDITIONAL EXCAVATION IF NECESSARY
FORCETHRUST
OBTAIN BEARING AREA AGAINSTLENGTH "L" AS REQUIRED TOUNDISTURBED SOIL
AGAINSTUNDISTURBEDSOIL
TO OBTAIN REQUIRED BEARING AREA
"H"ASREQUIRED
THRUST FORCE
"L"/2 "L"/2
"L"/2 "L"/2
OBTAIN REQUIRED BEARING AREAOR SLOPE UP IF NECESSARY TOPLACE CONC LEVEL WITH TOP OF PIPE
3. THRUST BLOCK SHALL BEAR ON UNDISTURBED SOIL.2. CONCRETE SHALL BE CLASS "A" OR "C".
OF 200 PSF/FT DEPTH.PRESSURE, OR BEARING AREA INDICATED ON THE DRAWINGS USING A PASSIVE RESISTANCE THAN 1500 PSF AT THE TOP OF THRUST BLOCK WHEN THE PIPE IS SUBJECTED TO ITS TEST
1. BEARING AREA IS THE AREA REQUIRED TO OBTAIN A MAXIMUM PRESSURE NOT GREATER NOTES:
AGAINST UNDISTURBED SOILOBTAIN BEARING AREALENGTH "L" AS REQUIRED TO -A TYPICAL SECTION A- A- A- FORCE THRUST TYP
SN 08/19/22
CY131 THRUST RESTRAINT - BURIED THRUST BLOCK
SERVICE STAMPED ON LID
ALL AROUND FRAME
8" FRAME ANDCOVER
TOP OF SURVEYMONUMENT (BRASSCAP), WATER VALVEBOX (8" CONC PIPE),OR SEWER PIPE (SIZEVARIES) 3/8" FINE DENSE GRADEDASPHALT MATERIAL
BITUMINOUS PAVEMENTNEW OR EXISTING
1/4" MAX
1" MAX.1/2" MIN.
CLASS "A" CONCRETE
3'-4" DIAMETER
TYP
CY739
S 12/29/2020
VALVE BOX FRAME - GRADE ADJUSTMENT CY733 BLOWOFF - DIRECT BURY TYP
11/13/19
#
MORTAR
3 1/4" THICK ST. TRASH RING. RING DIA. = VALVE BOX ID MINUS 1/8". 2 12" BLIND FLANGE W/SS BOLTS AND NUTS.
DRAWINGS.
1 6" TO EXISTING GRADE UNLESS OTHERWISE INDICATED ON THE KEY NOTES:
FRAME AND COVER
24"Ø MANHOLE
VALVE BODYSHALL NOT REST ON CI VALVE BOX. BOX 5 1/4" DIA. SLIP TYPE
BOTTOM OUTLET ALTERNATIVE
BLIND FLANGED
12"-DI CAP
6"-DI
TEE OUTLET
6" TANGENTIAL
AROUND
6" ALL
ENCASEMENT
CONC
BARREL
DEWATERING
12"-DI
MAIN
WATER
MAIN
WATER
EPOXY COATED
12"x12"x6" DI TEE
PAVED UNPAVED PAVED UNPAVED
8" (TYP)
2 1
CENTERED
#5@12" EW
VALVE BODY
SHALL NOT REST ON
CI VALVE BOX. BOX
5 1/4" DIA. SLIP TYPE
VALVE
FLANGED GATE
EPOXY COATED
3' SQ x 8" CONC PAD
FITTINGS
DI PIPE AND
EPOXY COATED
TOP HAT
RUBBER VALVE BOX
3 PAVEMENT PAVEMENT
ABC
ABC
CLEANOUT THRUST BLOCK
THRUSTBLOCK TYPE I
BLIND FLANGE (TYP)
FLANGE JOINTS (TYP)
TYPE 2
THRUSTBLOCK
FINISH FLOOR
TYPE 3 TYPE 4
TYPE 5
CLEANOUT
CLEANOUT
THRUST BLOCK
CLEANOUT
IRON BODY FERRULE WITHBRASS CTSK HEAD SCREWPLUG. MOUNT FLUSH WITHFLOOR.
MECHANICAL ORPUSH-ON JOINTS(TYP)
LONG RADIUS ELBOW
SCHEMATIC PLAN
SCHEMATIC PLAN SCHEMATIC PLAN
SCHEMATIC PLAN
VARIES
TERMINATION IN PAVEMENT
ABC PER PAVING SECTION
FLG OD + 4" WITH 12" MINIMUM
TAPPED FLG LABELED WITH WELDED ON PIPESIZE AND PROCESS
2 - #4 HOOP BARS
1/2"
CI FRAME AND COVER,MARKED "SEWER"
8"
1'-0"
5. FOR CLEANOUTS IN YARD AREA, PLACE 12" SQUARE BY 4" THICK CONCRETE PAD.4. CLEANOUT PIPE SHALL BE SAME SIZE AS LINE PIPE.
BOLTS.
3. ALL FLANGES SHALL BE TAPPED TO ALLOW THE INSTALLATION OF BLIND FLANGES WITH 2. CONCRETE RING SHALL BE PLACED AFTER PAVEMENT PLACEMENT.1. ALL THRUST BLOCKS SHALL BE PLACED PER TYPICAL DETAIL CY131.NOTES:
TYP
CY411
S SHEET 1 OF 2
CLEANOUTS
12/29/2020
TYP
CY411
S SHEET 2 OF 2
CLEANOUTS
12/29/2020
PlotDate:13-DEC-20243:12:16PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L143 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
11843A1000TC07.dgn
TYPICAL DETAILS
CIVIL 7
00TC07
hgarcia
DM
PREFORMED CHANNEL
WALLS AND LINTELS.DRAWINGS FOR REINFORCEMENT IN CMU WALL. REFER TO STRUCTURAL (TYP)WEIGHTS UNDER 200 LBS. U.O.N. 5/8" Ø WITH 3" OF EMBEDMENT FOR Z FITTING W/ CMU ANCHOR FOR CMU,
AS REQUIRED (TYP)ANCHORS, NUTS, AND LOCKWASHER
FITTINGS AT 2'-8" O.C. MAXPROVIDE INTERMEDIATE ZWHERE LENGTH EXCEEDS 2'-8" 6"MIN12"12"
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
GENERAL NOTES:
CONCRETE ANCHORS SHALL BE PER THE SPECIFICATIONS.
2. SUPPORTS TO BE SPACED IN ACCORDANCE WITH NEC REQUIREMENTS. 1. THIS DETAIL TYPICAL FOR BOTH VERTICAL AND HORIZONTAL MOUNTING.
EA080
S
TYP TO FULLY GROUTED CMU WALL
PREFORMED CHANNEL ATTACHMENT
ASREQUIRED
BACK
BOLT
PANEL
WASHER
& USE A STAR
SCRAPE PAINT
GROUND CONNECTION
THREADS TO ALLOW A
REMOVE PAINT FROM USE A WIRE BRUSH TO
THE ENCLOSURE
BACK WALL OF
PANEL TO THE
OF THE BACK
STUD MOUNTING
BACK PANEL
CHASSIS TO THE
BUS OR A
OF A GROUND
BOLT MOUNTING
WASHER
FLAT
HOLE
TAPPED
STUD
WELDED
(TYP)
BRACKET
MOUNTING
GROUND BUS OR
BACK PANEL
CHASSIS TO THE
BUS OR A
OF A GROUND
STUD MOUNTING
(TYP)
WASHER
STAR
STUD
WELDED
PAINT
SCRAPE
ENCLOSURE
BACK WALL OF
BOLT
(TYP)
GROUND LUG
COMPRESSION
(INSIDE) (OUTSIDE)
ENCLOSURE WALL
CONDUCTOR (TYP)
GROUNDING
EQUIPMENT WALL
ENCLOSURE
CHASSIS TO
BUS OR A
OF A GROUND
BOLT MOUNTING
(TYP)
NUT
OR
TYP
S
EG205 ENCLOSURE GROUNDING DETAILS
GROUND BUS MOUNTING
GROUND BUS
BOLT
WASHER
STAR
HOLE
TAPPED
BUS
GROUND GROUND LUG
ELECTRODE SYSTEM
CONDUCTOR TO GROUNDING
GROUNDING ELECTRODE
CONDUCTORS
GROUNDING
EQUIPMENT
ELEVATION VIEW SIDE VIEW
GROUND LUG
COMPRESSION
TYP
S
EG204 GROUND BUS CONNECTIONS
FINISHED GRADE
BACKFILL
DRAIN ROCK
1 1
KEY NOTES:
DIAMETER AS SPECIFIED).
GROUND ROD (LENGTH AND
OR IN SPECIFICATIONS.
SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
THROUGH CABLE TO GROUND ROD CONNECTION.
WHERE APPLICABLE.
"GROUND ROD". TRAFFIC RATED
CAST IRON COVER MARKED
w/12" DIAMETER OPENING & ROUND
PRECAST CONCRETE
TYP
S
EG051 GROUND ROD AND GROUNDWELL
EXOTHERMIC CONNECTION
GRADE
FINISHED
1 1
3'-0" (MIN)
SOIL
OR IN SPECIFICATIONS.
SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
SPECIFIED).
(LENGTH AND DIAMETER AS
GROUND ROD
THROUGH CABLE TO GROUND ROD CONNECTION.
KEY NOTES:
TYP
S
EG052 GROUND ROD
EXOTHERMIC CONNECTION
GRADE
FINISHED
HORIZONTAL TEE CONNECTION.
KEY NOTES:
1 1
3'-0" (MIN) SOIL
IN SPECIFICATIONS.
SIZE AS INDICATED ON DRAWINGS OR
GROUND GRID CONDUCTOR.
TYP
S
EG151 COPPER GROUNDING CABLE CONNECTION
EXOTHERMIC CONNECTION
C PHASEB PHASEA PHASE
TRANSFORMER
FIRST DISCONNECTING DEVICE AFTER
EQUIPMENT FRAME
INTEGRALLY BONDED TO
EQUIPMENT GROUND BUS
EQUIPMENT FRAME
GROUND PAD
TRANSFORMER
CONDUCTOR
GROUNDING ELECTRODE
TYPE BUSHINGS
GROUNDING
CONDUIT
NEUTRAL BUS
SYSTEM BONDING JUMPER
DRAWINGS
SYSTEM AS INDICATED ON THE
TO GROUNDING ELECTRODE
DRAWINGS
SYSTEM AS INDICATED ON THE
TO GROUNDING ELECTRODE
EQUIPMENT BONDING JUMPER
TYP
S
EG511 TRANSFORMER (NON-UTILITY) 3-PHASE, 4-WIRE
SECONDARY POWER GROUNDING DETAIL
PlotDate:13-DEC-20243:13:54PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L144 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
RM
11843A1000TE01.dgn
TYPICAL DETAILS
ELECTRICAL 1
00TE01
OWestbrook
(TYP
)
3.0"
(TYP)
3.0"
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
1 2 2
3 CONDUIT
FLUSH MOUNTED
SUSPENDED
CONDUIT
LUMINAIRE
LUMINAIRE
HANGER
CONDUIT
HANGER
CONDUIT STRAP OR EQUAL
HANGER w/SAFETY
APPLETON FHSN
OR EQUAL
FHLF LOOP
APPLETON
OR EQUAL
AHG HANGERAPPLETON
TYP
S
EL200
TO ATTACHMENT DETAIL
PREFORMED CHANNEL REFER
AS REQUIRED (TYP)
STUD NUT OR HANGER
LINEAR FIXTURE NUT,
TO ATTACHMENT DETAIL
PREFORMED CHANNEL REFER
ROD
CHAIN OR
LINEAR LUMINAIRE MOUNTING
# KEY NOTES:
3. CAP END CONDUIT AS REQUIRED.2. LENGTH AS REQUIRED FOR INDICATED MOUNTING HEIGHT.1. USE MEYERS HUB IN WET AND/OR CORROSIVE AREAS. 54321
S
EM001 REINFORCED CONCRETE DUCT BANK
1 4
2 3
GROUND WIRESDBC
2 4
5 CONCRETE (RED)CLASS CE
FINISHED GRADE
12"
24"
BELOW
GRADE (MIN)"
TYP
1 CURING.
3. MAKE PROVISIONS TO PREVENT CONDUIT FLOTATION DURING CONCRETE PLACEMENT & CONDUITS.
REFER TO DUCT BANK SECTIONS, AND CONDUIT SCHEDULE FOR NUMBER AND SIZE OF SPECIFICATION TO ACCOMMODATE ACTUAL NUMBER OF CONDUITS WITHIN DUCT BANK.
2. ADJUST SIZE OF DUCT BANK BASED UPON THESE GUIDELINES AND THE DUCT BANK
1. DIMENSIONS SHOWN ARE MINIMUM.
NOTES:
6 6
6 6 7
8 2
78 3
9 OTHERWISE INDICATED ON THE DRAWINGS.
#4/0 SDBC GROUND WIRE UNLESS
THE DUCT BANK.
BOND THE DUCT BANK GROUND WIRE TO THE GROUNDING SYSTEM AT BOTH ENDS OF VERTICAL LEGS EACH SIDE.
LOWER PORTION OF TIES COULD BE U-BARS IF UPPER PORTIONS PROVIDES 1'-4" CONTRACTOR'S OPTION TO PROVIDE 1'-4" LAP LENGTH EACH SIDE OF HORIZONTAL TIE.1'-4" OR 135 DEGREE HOOK FOR SHALLOW DUCT BANKS SHALLOWER THAN 21"REFER TO DUCT BANK SECTIONS AND SPECIFICATIONS FOR CONDUIT REQUIREMENTS.PVC CONDUIT SPACERS ON 8'-0" CENTERS (MAXIMUM). LOCATE 12" FROM TIES.
SUPPORTS AT INTERVALS OF 24" TO REDUCE DEFLECTION.
PVC CONDUIT SPACER ALONG LENGTH OF DUCT BANK. PROVIDE PRECAST BAR MINIMUM OF TWO PRECAST CONCRETE BAR SUPPORTS PLACED UNDER A TIE AT EACH #4 REINFORCING STEEL TIES MAXIMUM 24" ON CENTER ALONG LENGTH OF DUCT BANK.
BANK.
#4 REINFORCING STEEL 12" MAXIMUM ON CENTER AROUND ENTIRE PERIMETER OF DUCT KEY NOTES:
9 5
3-WAY SWITCH WIRING DIAGRAM
HOT
NEUTRAL
HOT
NEUTRAL
SWITCH
3-WAY
SWITCH
3-WAY
SWITCH
3-WAY
SWITCH
3-WAY
TYP
S
EL700 3-WAY SWITCH ONE-LINE DIAGRAM
4-WAY SWITCH WIRING DIAGRAM
HOT
NEUTRALNEUTRAL
HOT
SWITCH
3-WAY
SWITCH
4-WAY
SWITCH
3-WAY
SWITCH
3-WAY
SWITCH
4-WAY
SWITCH
3-WAY
TYP
S
EL701 4-WAY SWITCH ONE-LINE DIAGRAM
EL506 POLE FOUNDATION
TYP TRAFFIC AREAS
S
1. SEE NOTE
6-#5 MIN.
LAP SPLICE @ TOP SPIRAL.
#3 SPIRAL MIN. SEE NOTE 1.
B- SECTION
3"CLR
POLE BASE
CONC PIER
POLE
4"
MIN LBOLT ANCHOR C
CONDUIT
GRADE
ELEVATION
COMPACTED SOIL
CONCRETECLASS "A" SEE
LAP SPLICE
FINISHED
CONDUIT(S)
ELECTRICAL ENCASED
SEENOTE1.
5'-0"MIN
PITCH
3@3"
2"CLR
A- B- PITCH OF SPIRAL MIN8" 3"CLR GROUT MIN 1" NON-SHRINK POLE
COVER
POLE BASE
TYP
SC001
6"PITCH2
'-0"MIN
3'-0"
SEENOTE1
2'-0"DIAMIN
SEENOTE1
2'-0"DIAMIN
GENERAL NOTES:
INCREASE DIMENSIONS AS REQUIRED.
OTHERWISE NOTED. PROVIDE WIND LOAD CALCULATIONS AND
1. USE MINIMUM DIMENSIONS AND REINFORCEMENT SHOWN UNLESS
PER POLE MFR REQUIREMENTS
WASHERS, AND LEVELING NUTS
SST ANCHOR BOLTS, NUTS, LOCK
A- SECTION
PlotDate:13-DEC-20243:06:17PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L145 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
RM
11843A1000TE02.dgn
TYPICAL DETAILS
ELECTRICAL 2
00TE02
hgarcia
GRADE AT OPEN AREAS GRADE AT ROADWAYS
4"
6"MIN
3" (TYP)
3"
4"
2'-6"
12"
(TYP)"
18"
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
TYP
S
EM058
SUBGRADE
PREPARED
GRADE
FINISHED
PANEL
KNOCKOUT
PRE-FORMED
COVER
MANHOLE ROADWAY
COATING
EXTERIOR
DRAIN SUMP
GROUND ROD
3/4" x 10'-0"
PULLING IRON (TYP)
(TYP)
1 6
3 5
8 4
2 MAX
6"
EM001
EM070
TYP
TYP
MATERIAL
BASE 9
(TYP 4 SIDES)12" MIN
KEY NOTES:
1 2
3 4
5 689
ELECTRICAL HANDHOLE:PRECAST CONCRETE W/ MANHOLE COVER
NOTES:
1. 2.
3. BANKS AT EACH HANDHOLE.
SEE DRAWINGS FOR ORIENTATION, NUMBER, AND SIZE OF DUCT
USING #4 AWG BARE COPPER CABLE.
BOND ALL METALLIC ITEMS INSIDE HANDHOLE TO GROUND ROD
INTERIOR DIMENSIONS: 48"WIDE x 48"LONG x 48"DEEP)
ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE (MAXIMUM
PROVIDE MINIMUM INTERIOR DIMENSIONS AS SHOWN IN THE
7 7
COURSE.
BASE MATERIAL: PROVIDE MIN 12" COMPACTED AGGREGATE BASE PROVIDE ONE PULLING IRON ON EACH WALL OF HANDHOLE.
FOR CONNECTION REQUIREMENTS.
GROUNDING CABLE CONNECTION. REFER TO THE SPECIFICATIONS HANDHOLE.
MAXIMUM TOP SLAB OVERHANG IS TYPICAL AROUND 4 SIDES OF
PROOFING.
COAT EXTERIOR WALLS BELOW GRADE WITH BITUMINOUS DAMP
MATERIAL BELOW.
18" SQUARE FILTER FABRIC TO ISOLATE GRAVEL FROM BASE
THROUGH FLOOR OF HANDHOLE. SET SUMP OPENING OVER MINIMUM PROVIDE MINIMUM 4 INCH DIAMETER, GRAVEL FILLED PENETRATION WALL AROUND HANDHOLE.
PREFORMED KNOCKOUT PANELS. PROVIDE KNOCKOUTS ON EACH
INSTALL DUCT BANKS ONLY THROUGH CAST-IN OPENINGS OR
FOR CONNECTION REQUIREMENTS.
LOCATED OUTSIDE OF DUCT BANK. REFER TO THE SPECIFICATIONS BOND DUCT BANK AND INTERIOR GROUND CABLE TO GROUND ROD COVER.
PROVIDE 36"Ø EMBEDDED TOP FLANGE FRAME AND MANHOLE
ELECTRIC
COUPLING
CONDUIT
PCS
INTERNAL GROUND WIRE
#4 GROUND WIRE
CONDUIT
PCS
GRADE
CONDUCTORS
4 5
32 TYP
S
EM052
FINISHED GRADE
1 1/2" ABOVE
1 GRAVEL
18" MIN 7
6 PRECAST POLYMER CONCRETE ELECTRICAL HANDHOLE:
HANDHOLE
CONCRETE
POLYMER PRECAST
# KEY NOTES:
WAY PAST OUTSIDE LIMITS OF HANDHOLE.
7. GRAVEL BED FOR LEVELING & DRAINAGE. MINIMUM 12" DEEP & EXTENDING AT LEAST 6" EACH 6. PROVIDE "TIER"-RATED COVER PER MANHOLE AND HANDHOLE SCHEDULE.5. PACK COUPLING AREA WITH DUCT SEAL BY MANVILLE OR APPROVED EQUAL.4. NIPPLE (USED TO COMPACT DUCT SEAL IN COUPLING).
GROUND CONDUCTORS IN EACH CONDUIT.
3. INSULATED GROUNDING BUSHINGS. BOND BUSHINGS TO EACH OTHER WITH #4 WIRE AND TO WIRES AND CABLES.
2. ALLOW SUFFICIENT SPACE BETWEEN THE CONDUIT AND HANDHOLE LID FOR BENDING RADIUS OF POLYMER CONCRETE HANDHOLES IN ROADWAYS.
1. PRECAST POLYMER CONCRETE HANDHOLE WITH OPEN BOTTOM FOR DRAINAGE. DO NOT INSTALL COVER
TYP
S
EM015 DIRECT BURIED CONDUIT OR CABLE
FINISHED GRADE
BACKFILL
WARNING TAPE
SAND BACKFILL
CONDUIT OR CABLE
DIRECT BURIED
2. REFER TO THE SPECIFICATIONS FOR TRENCH BACKFILL REQUIREMENTS.
DRAWINGS.
1. ALL DIMENSIONS ARE MINIMUM UNLESS OTHERWISE INDICATED ON THE NOTES:
TYP
S
EM022 DUCT BANK ENTRY
INTO ELECTRICAL EQUIPMENT
NOTES:
ENCLOSUREELECTRICALFOUR SIDESSEALANT ALL1 1/2" JOINT
ENCLOSURE.
MUST FIT IN MANUFACTURER PROVIDED WINDOW IN BOTTOM OF ELECTRICAL AND NUMBER OF CONDUITS. CONDUITS AT TOP OF HOUSE KEEPING PAD
1. OPENING SIZE IN CONCRETE HOUSE KEEPING PAD IS SET BY CONDUIT SIZE TYP
TYP
SC012
SD702 PAD
HOUSEKEEPING
ELECTRICAL
SLAB
CONCRETE
TYP
EM001
EQUIPMENT GROUND BUS
CONDUCTOR CONNECT TO
GROUNDING ELECTRODE
#4@12"
#4 U-SHAPED BARS
LAP SPLICE
(TYP)
GRADE
SLAB ON
1 1
3" CLR COVER
TYP
S
EM032
SLAB ON GRADE
TYP
TYP
TYP
EM001
TYP
EM001
SC012
TYP
SD382
EM107
RISER FROM DUCT BANK
GENERAL NOTES:KEY NOTES:
1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS.
WHERE THE CONDUIT IS NOT PROTECTED BY AN EQUIPMENT PAD.PROVIDE CONDUIT HOUSE KEEPING CURB AT ALL LOCATIONS CONTINUING DUCT BANK AS INDICATED ON THE DRAWINGS.
EM020 DUCT BANK RISER
TYP
S
#4@12"
#4 U-SHAPED BARS
LAP SPLICE
(TYP)
1 TYP
EM001
TYP
EM001
3" CLR COVER
DRAWINGS.
THE
INDICATED ON
DUCT BANK AS
CONTINUING
KEY NOTES:
GENERAL NOTES:
1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS. #
EQUIPMENT ABOVE.
1. ADJUST DUCT SPACING TO FIT OPENING IN THE SLAB AND
(TYP)
INSULATED THROAT
BUSHING WITH
METAL GROUNDING
PlotDate:13-DEC-20243:08:58PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L146 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
RM
11843A1000TE03.dgn
TYPICAL DETAILS
ELECTRICAL 3
00TE03
OWestbrook
SET TOP OF MANHOLE FLUSH
AT PAVING OR SIDEWALKS
SET TOP OF MANHOLE FLUSHAT PAVING OR SIDEWALKS,
FRAME AND MANHOLE COVER36"Ø EMBEDDED TOP FLANGE
COATING
EXTERIOR
TIE - OFF
LADDER
AND/OR RISERSPRECAST GRADE RINGS
COVERFRAME AND MANHOLE36"Ø BOTTOM FLANGE
SUBGRADE
PREPARED
BASE MATERIAL
(LOCATIONS PER FABRICATOR)PRECAST STRUCTURE JOINT
CHANNELS FOR CABLE RACKSPREFORMED AND EMBEDDED
MANHOLE BASE
GROUND CABLE
BANK COPPER
#4/0 BARE DUCT
1/2"Ø TYPE 316 SST ROD
12" (TYP)
31/2"
BASE MATERIAL
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
IRON
PULLING
COATING
EXTERIOR
AROUND)AREAS (TYP
CABLE ROUTING
IRONPULLING
GROUND ROD3/4" x 10'-0"
REINFORCING BARSTIE INTO TOP OF SLAB
SURROUNDING GRADE
MANHOLE 2" TO 4" ABOVE
AT EARTH, SET TOP OF
MAX
8"
TYP
S
EM062
PRECAST CONCRETEELECTRICAL MANHOLE:
B SECTION - C- D- SLOPE SLOPE PANEL KNOCKOUT PREFORMED ACCESS MANHOLE
MINMINCLR MIN
(TYP)
MIN
CLR MIN
MIN
(TYP)
MIN
SLOPE SLOPE
SURROUNDING GRADE
MANHOLE 2" TO 4" ABOVE
AT EARTH, SET TOP OF
#5 @ 12" EW
CONCRETECLASS B CLASS A OR
SUMP
CAST-IN
SUMP
CAST-IN
(ABOVE)
ACCESS
CAST-IN SUMP
A
LADDER TIE - OFF
PLAN - LAYOUT
E- S
OIL
18"18"18
"36"
18"
DUCT BANK
24" MIN
WIDTH
LENGTH
18"
18"
18"
6"MIN
2"CLR
6"MIN
12" MIN
4"MIN
2'-0"MIN
HEIGHT(7'-0"MIN)
LADDER TIE-OFF
3'-0"MINCLR(TYP)
NOTES:
1. 2.
3. 4.
5. SCHEDULE.
IN THE ELECTRICAL HANDHOLE AND MANHOLE
PROVIDE MINIMUM INTERIOR DIMENSIONS AS SHOWN
SHOWN IN THE HANDHOLE AND MANHOLE SCHEDULE.
PROVIDE MANHOLE ALTERNATES (TOP OR BASE) AS
GROUND ROD USING #4 AWG BARE COPPER CABLE.
BOND ALL METALLIC ITEMS INSIDE MANHOLE TO
MANHOLE.
OF DUCT BANKS AND PENETRATIONS AT EACH
SEE DRAWINGS FOR ORIENTATION, NUMBER, AND SIZE
INSULATOR CLAMPS PER TYPICAL DETAIL EM076.
RACK MEDIUM VOLTAGE CABLES USING PORCELAIN
BANK
DUCT
BANK
DUCT
BANK
DUCT
ALTERNATE 1: SECTIONEXPOSED TOP SLAB
MAX
8"
BASE WITH SUMP OR BALLAST
CALTERNATE 2: SECTIONOVER
6" MIN
TIE - OFF PER DETAIL E.
AT ONE SIDE OF MANHOLE ACCESS, PROVIDE LADDER
REQUIREMENTS.
FULL MIXING, PLACING, FINISHING AND CURING
SEE SPECIFICATIONS FOR CAST-IN-PLACE CONCRETE
CORRIDOR BELOW MANHOLE COVER.
SLOTTED COVER. LOCATE SUMP OUTSIDE VERTICAL
MINIMUM 12" DIAMETER SUMP WITH REMOVABLE
COURSE.
PROVIDE MIN 12" COMPACTED AGGREGATE BASE
BELOW EACH DUCT BANK PENETRATION.
PROVIDE ONE PULLING IRON ON EACH WALL ABOVE OR
UNCOATED.
DAMP PROOFING. LEAVE EXPOSED TOP SLAB
COAT EXTERIOR WALLS OF MANHOLE WITH BITUMINOUS
MANHOLE WITH BITUMINOUS DAMP PROOFING.
COAT EXTERIOR WALLS AND BURIED TOP SLAB OF
MANHOLE.
PROVIDE KNOCKOUTS ON EACH WALL AROUND
WINDOWS OR PREFORMED KNOCKOUT PANELS.
INSTALL DUCT BANKS ONLY THROUGH BLOCKOUTS,
REQUIREMENTS.
GROUND ROD. SEE SPECIFICATIONS FOR CONNECTION
BOND DUCT BANK AND INTERIOR GROUND CABLE TO
VERTICAL ACCESS CORRIDOR BELOW MANHOLE COVER.
REMOVABLE SLOTTED COVER. LOCATE SUMP OUTSIDE
MINIMUM 12" DIAMETER x MIN 2" DEEP SUMP WITH
PERIMETER OF MANHOLE.
KNOCKOUTS AND MAXIMUM 24" ON CENTER AROUND
SPACE EMBEDDED CHANNELS TO CLEAR DUCT BANK
FLOTATION, SEE SECTION D (ALTERNATE 2).
WITH DEEPER SUMP OR CONCRETE BALLAST TO RESIST
STANDARD MANHOLE BASE SHOWN. FOR MANHOLES SEE SECTION C (ALTERNATE 1).SECTION B. FOR MANHOLES WITH EXPOSED TOP SLAB,
MANHOLE ACCESS FOR BURIED MANHOLE SHOWN IN
KEY NOTES:
6" MIN
R = 2 1/2"
R = 2 1/2"
6" MIN
12" MIN
(TYP 4 SIDES)
(12"MIN)
1 2
3 4
5 6789
10 11
12 13
B- TYP (TYP)
EM001
4 8
13 12
10 11
1 10
2 3
9 5 4
5 6
13 7
9 TYP
EM070
DUCT BANKS)(TYP AT
TYP
SB110
TYP
CS124
TYP
SB110
PlotDate:13-DEC-20243:13:11PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L147 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
RM
11843A1000TE04.dgn
TYPICAL DETAILS
ELECTRICAL 4
00TE04
hgarcia
CHANNEL CAP
CONDUIT
CHANNEL
PREFORMED
ANCHORS
CONCRETE
GROUT
1" NON-SHRINK
CONDUIT CLAMP
3"
3-1/2"
PVC CONDUIT
FLOOR
FINISHED
TO FLOOR
DOWEL CURB
CHAMFER
CONDUIT
#3 HOOP
DRAINAGE.TOP OF CURB FOR CROWN OR SLOPE
STEEL CONDUITPVC COATED
(TYP)CONDUIT COUPLING
(TYP)"
12"
PVC FEMALE ADAPTER
ELBOW (TYP)
STEEL CONDUIT
PVC COATED
WALL
ENCASEMENTHEIGHT,H
WALL
ENCASEMENTHEIGHT,H
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
10' MAX
6"
1 ENCASED CONDUITSEXPOSED CONDUITS
WASHER OR HEX NUT
CONDUIT CAP
NYLON PULL ROPE
CONDUIT
NUT TO PIPE CAP
WELD WASHER OR HEX
BRASS CONDUIT PLUG.
STEEL CONDUIT.
PVC COATED RIGID
1. PROVIDE 2" MIN CLEAR BETWEEN ADJACENT CONDUITS
NOTES:
STEEL COUPLING.
PVC COATED RIGID
TYP
S
EM105 SPARE CONDUIT DETAIL
WASHER OR HEX NUT
TIE PULL ROPE TO
CURB
OR HOUSEKEEPING
FINISHED FLOOR
SIZE PREFORMED CHANNEL FOR CONDUITS INDICATED ON THE DRAWINGS.
KEY NOTES:
1 TYP
S
EM104
FOR ELECTRICAL CONDUITSCONDUIT FLOOR SUPPORT
TYP
# KEY NOTES:
AND LARGER.
3. FIELD BEND 1" CONDUITS. PROVIDE MANUFACTURED PCS ELBOWS FOR CONDUITS 1.25" 2. TYPICAL BOTH SIDES, FRONT AND REAR.1. COORDINATE REINFORCING STEEL REQUIREMENTS WITH THE GENERAL CONTRACTOR.
TYP
S
EM107 CONDUIT HOUSEKEEPING CURB
2 1
EM116
3 EM076 PORCELAIN CABLE CLAMP
TYP
S
PREFORMED CHANNEL
3 2
1 # KEY NOTES:
3. SIZE HOLE BASED ON CONDUCTOR SIZE
2. PIPE CLAMP
1. PORCELAIN CABLE CLAMP
EM070 ENCASED CONDUITS AT MANHOLES OR
TYP STRUCTURES - W/O WATERSTOP
S
CONDUIT(S)
OUTSIDE OF
STRUCTURE
INSIDE OF
DUCTBANK)
1" (TYP AROUND
STIRRUPS
STRUCTURE
FITTING (TYP)
END BELL
CONDUCTOR
GROUNDING
REINFORCEMENT
LONGITUDINAL
1 2
4 3
TYP
EM001
TYP
SD382
TYP
SC012
# KEY NOTES:
REINFORCEMENT PERREQUIRED. FOR CAST-IN-PLACE STRUCTURES, PROVIDE
4. PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENING AS
ALTERNATE WITH TYPICAL REINFORCEMENT FOR 6" SPACING.
3. ADDITIONAL #4 x 12'-0" @ 12" ON ALL FOUR FACES OF ENCASEMENT.
HEIGHT IN INCHES.
SPACING IN INCHES = (H-4)/2 WHERE H = CONCRETE ENCASEMENT
2. FOR FIRST 12'-0" FROM INSIDE FACE OF STRUCTURE, STIRRUP CONDUCTOR.
MANHOLE. BOND GROUNDING FITTING TO DUCTBANK GROUNDING
1. PROVIDE GROUNDING FITTING FOR METALLIC CONDUITS ENTERING
CONDUIT(S)
OUTSIDE OF
STRUCTURE
INSIDE OF
STIRRUPS
STRUCTURE
FITTING (TYP)
END BELL
CONDUCTOR
GROUNDING
(TYP AROUND)WATERSTOP
REINFORCEMENT
LONGITUDINAL
1 2
(TYP AROUND)
4"
2" MIN
TYP
TYP
TYP
# KEY NOTES:
ALTERNATE WITH TYPICAL REINFORCEMENT FOR 6" SPACING.
4. ADDITIONAL #4 x 12'-0" @ 12" ON ALL FOUR FACES OF ENCASEMENT.
ENCASEMENT HEIGHT IN INCHES.SPACING, IN INCHES = (H-4)/2, WHERE H = CONCRETE
3. FOR FIRST 12'-0" FROM INSIDE FACE OF STRUCTURE, STIRRUP ENCASEMENT.
2. 6" PVC CENTERBULB WATERSTOP TYPICAL AROUND PERIMETER OF CONDUCTOR.MANHOLE. BOND GROUNDING FITTING TO DUCTBANK GROUNDING
1. PROVIDE GROUNDING FITTING FOR METALLIC CONDUITS ENTERING S
EM071 ENCASED CONDUITS AT MANHOLES OR
1 3
2 4
S180
EM001
STRUCTURES - WITH WATERSTOP
S130
TYP
PlotDate:13-DEC-20243:12:26PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L148 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
RM
11843A1000TE05.dgn
TYPICAL DETAILS
ELECTRICAL 5
00TE05
hgarcia
SLAB
CONDUIT
SLAB
CONDUIT
(TURNING)
CONDUIT
SLAB
CONDUIT
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
TYP
KEY NOTES:
CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.
MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
PREVENT FLOTATION.
OR BOLSTERS. TIE CONDUITS TO SUPPORTS & ANCHOR TO
SUPPORT CONDUITS ON ADDED REINFORCEMENT CHAIRS
TYP
SEE DETAIL.
FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
PLACING CONCRETE.
MAINTAINED, CONTACT ENGINEER FOR INSTRUCTION'S BEFORE
WHERE HORIZONTAL & VERTICAL CLEARANCES CANNOT BE
1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.
NOTES:
EACH PAIR.
HORIZONTAL & VERTICAL SPACING SHOWN BETWEEN
4 WHERE MORE THAN 2 RUNS ARE STACKED, PROVIDE 3
3 1
1 2
MIN 1 1/2" CLEAR
MIN 2" CLEAR
MIN 1 1/2" CLEAR
TYP
S
EM116 EMBEDDED CONDUIT IN CONCRETE SLAB
STACKED RUNS
TYP
SC001
REINFORCEMENT MAT
TOP STRUCTURAL
REINFORCEMENT MAT
BOTTOM STRUCTURAL
21 4
3 1
1 2
MIN 1 1/2" CLEAR
MIN 1 1/2" CLEAR
REINFORCEMENT MAT
TOP STRUCTURAL
REINFORCEMENT MAT
BOTTOM STRUCTURAL
TYP
TYP
KEY NOTES:
CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.
MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
TYP
S
EM115 EMBEDDED CONDUIT IN CONCRETE SLAB
SINGLE RUN
SEE DETAIL.
FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
TYP
SC001
TIE CONDUITS TO SUPPORTS & ANCHOR TO PREVENT FLOTATION. 3 SUPPORT CONDUITS ON ADDED REINFORCEMENT CHAIRS OR BOLSTERS. 21 AND BOTTOM REINFORCEMENT MATS.
4 CENTER LARGEST DIAMETER CONDUIT BETWEEN TOP
PLACING CONCRETE.
MAINTAINED, CONTACT ENGINEER FOR INSTRUCTION'S BEFORE
WHERE HORIZONTAL & VERTICAL CLEARANCES CANNOT BE
1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.
NOTES:
REINFORCEMENT MAT
KEY NOTES:
SEE DETAIL.
FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.
MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
SAGGING.
REQUIRED TO PREVENT #4 CONDUIT SUPPORTS FROM
TYPICAL SLAB REINFORCEMENT SUPPORT. SPACE AS
TYP
TIE CONDUITS TO SUPPORTS & ANCHOR TO PREVENT FLOTATION. 1 1/2
1 "T"
REINFORCEMENT (TYP).
PROVIDE MIN 2" CLEAR BETWEEN CONDUIT & ADJACENT PARALLEL 1 5
5 4
4 3
2 11
321
#5 @ 12" CLEAR"
MIN 2"
EACH CORNER
ADD CONTINUOUS #5
CLEAR"
MIN 3"
REINFORCEMENT
SLAB BOTTOM MAT SLAB
0" (TYP)
(TYP)"
MIN
1.5T
3" CLEAR
#4 @ 24"
TYP
SC001
BEFORE PLACING CONCRETE.BE MAINTAINED, CONTACT ENGINEER FOR INSTRUCTIONS
WHERE HORIZONTAL & VERTICAL CLEARANCES SHOWN CANNOT
1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.
NOTES:
EM118 ENCASED CONDUIT UNDER CONCRETE SLAB ON GRADE
S
TYP
LAPSPLICE
KEY NOTES:
PLACING CONCRETE.
MAINTAINED, CONTACT ENGINEER FOR INSTRUCTION'S BEFORE
WHERE HORIZONTAL & VERTICAL CLEARANCES CANNOT BE
1. MOVE CONDUITS TO AVOID CONFLICTS WITH WATERSTOPS.
NOTES:
SEE DETAIL.
FOR REQUIRED TOP AND BOTTOM COVER OVER REINFORCEMENT
CONDUITS = 4X OUTSIDE DIAMETER OF THE LARGER CONDUIT.
MINIMUM ON CENTER HORIZONTAL SPACING OF PARALLEL
SAME HORIZONTAL PLAN.
THAN DIAMETER OF THE LARGER CONDUIT IN THE
SPACING BETWEEN PARALLEL CONDUITS NOT LESS
WHERE CONDUITS CROSS, PROVIDE MIN HORIZONTAL
& MAINTAIN CLEARANCE SHOWN.
SUPPORT CONDUITS AT CROSSING TO PREVENT SAG
EACH PAIR.
HORIZONTAL & VERTICAL SPACING SHOWN BETWEEN
6 WHERE MORE THAN 2 RUNS ARE STACKED, PROVIDE 5
32 4
3 1 4
3 5
2 1
1 TYP
S
EM117 EMBEDDED CONDUIT IN CONCRETE SLAB
CROSSING RUNS
TYP
SC001
REINFORCEMENT MAT
TOP STRUCTURAL
REINFORCEMENT MAT
BOTTOM STRUCTURAL
TYP
TYP
MIN 1 1/2" CLEAR
MIN 2" CLEAR
MIN 1 1/2" CLEAR
CONDUITS TO SUPPORTS & ANCHOR TO PREVENT FLOTATION.
OCM METAL BAR SUPPORT PRODUCT TYPE OR EQUAL. TIE
SUPPORT CONDUITS ON ADDED REINFORCEMENT BOLSTERS,
PlotDate:13-DEC-20243:10:50PMUser:svcPWModel:Layout1ColorTable:gshade.ctbDesignScript:Carollo_Std_Pen_v0905.penPlotScale:1:1L149 ASTSAVEDBY:
PROJECT NO. FILE NAME:
CECE
RM
11843A1000TE06.dgn
TYPICAL DETAILS
ELECTRICAL 6
00TE06
hgarcia
DEEP BOX
MAXIMUM 4"
T.O. OPENING
GROUTED CELL
REINFORCEMENT
VERTICAL LINTEL
CMU LINTEL
DEEP BOX
MAXIMUM 4"
STRUCTURAL DRAWINGS.
BEYOND. REFER TO
VERTICAL REINFORCEMENT
CELL.
BARS PER REINFORCED
WALLS MAY HAVE 2
REINFORCEMENT SOME
AND SPACING OF
DRAWINGS FOR SIZE
REFER TO STRUCTURAL REINFORCEMENT.
VERTICAL
No. 20740
REV DATE BY DESCRIPTION
DATE
CHECKED
DRAWN
DESIGNED
11843A.10
JOB NO.
DRAWING NO.
SHEET NO.
SCALES ACCORDINGLY
VERIFY SCALES
THIS SHEET, ADJUST
IF NOT ONE INCH ON
BAR IS ONE INCH ON
ORIGINAL DRAWING
0 1"
OF
CITY OF ROSEVILLE
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
AB
CD
E
F
G G
®
178
AQUIFER STORAGE AND RECOVERY WELLS PROJECT
DECEMBER 2024
NOT FOR CONSTRUCTION
DRAFT FINAL SUBMITTAL
A- -A
A - - A
BONDING JUMPER
EXPANSION FITTING
CONDUIT
CONDUIT CLAMP
UNISTRUT
FITTING
DEFLECTION
CONDUIT
EXPANSION JOINT
STRUCTURE
SLABSTRUCTURAL
NIPPLE
CONDUIT
DETAIL
REFER TO ATTACHMENT
GENERAL NOTES:
FROM THE EXPANSION JOINT.STAGGERED, BUT IN NO CASE SHALL A FITTING BE MORE THAN 3'-0"
1. WHERE SEVERAL CONDUITS ARE INSTALLED, FITTINGS MAY BE TYP
S
EM126
CONCRETE WALL EXPANSION JOINTEXPOSED EXPANSION/DEFLECTION FITTING AT PLAN
SECTION
NOTES:
CONDUITPVC COATED
PLATE
MOUNTING
FIXTURE
SUPPORTBOX
BELOWTO
8"MINGROUT
NOTE 2
3. REFER TO STRUCTURAL DRAWINGS FOR REINFORCEMENT IN WALLS AND LINTELS.
2. DISCONTINUE VERTICAL BAR AT BOX. PROVIDE VERTICAL BARS IN CELLS NEXT TO BOX.
REQUIREMENTS.
1. REFER TO STRUCTURAL DRAWING FOR ADDITIONAL GROUT AND REINFORCEMENT
CMU WALL
EM171
S
TYP
ELECTRICAL BOX ABOVE OPENINGFULLY GROUTED CMU WALL
CONDUIT
GROUT
NON-SHRINK
FILL WITH
3. PROVIDE 8" MINIMUM CENTER-TO-CENTER SPACING FOR CONDUITS.
AGENT IMMEDIATELY PRIOR TO GROUTING.
2. ROUGHEN SURFACE OF OPENING TO A 1/4" AMPLITUDE AND APPLY EPOXY CEMENT BONDING MAINTAIN MIN 2" CLEAR BETWEEN CORE DRILLED OPENING AND REINFORCEMENT.
1. PROVIDE NON-DESTRUCTIVE TESTING TO DETERMINE LOCATIONS OF REINFORCEMENT.
NOTES:
CMU WALL
EM173
S
TYP
CORE HOLE PENETRATIONFULLY GROUTED CMU WALL
CONDUIT
STRUCTURE
1. PROVIDE ADAPTERS AS REQUIRED TO COUPLE PVC CONDUIT TO THE FITTING.
NOTES:
APPROVED EQUAL.
O-Z/GEDNEY TYPE DX OR
DEFLECTION FITTING
JOINT
EXPANSION
STRUCTURE
TYP
S
EM120 EMBEDDED CONDUIT
DEFLECTION/EXPANSION FITTING
FITTING
DEFLECTION
FITTING
EXPANSION
SLABSTRUCTURAL BONDING JUMPER
JOINT
EXPANSION
STRUCTURE
FOR DEFLECTION
VOID TO ALLOW
1"MIN
CONDUIT CONDUIT
THE FITTING.
2. PROVIDE ADAPTERS AS REQUIRED TO COUPLE PVC CONDUITS TO
1. WRAP ENTIRE ASSEMBLY IN BURLAP PRIOR TO CONCRETE POUR.
NOTES:
NIPPLE
CONDUIT
TYP
S
EM121 EMBEDDED COMBINATION
DEFLECTION/EXPANSION FITTING
STRUCTURE CONDUIT
BONDING JUMPER
CONDUIT MANUFACTURER.
2. FOR PVC COATED CONDUIT, USE PVC COATED EXPANSION FITTING BY EXPANSION JOINT.
BUT, IN NO CASE SHALL FITTINGS BE MORE THAN 5'-0" FROM STRUCTURE'S