Cities Index.
Agenda packet, regular meeting

Montebello City Council
November 12, 2025

Document
Agenda packet, regular meeting
Meeting
November 12, 2025
Body
Montebello City Council
Pages
1,646
Original file
257.7 MB
Text extracted from the city's file for reading and search. Open the original on montebelloca.api.civicclerk.com. That file is the official record.

WB3
FC
T
G
M
C
W
W 2 C
G
P
H
P
G
H
DR
H
D
A
M
DR
DR
H
H
P
RD
Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom A 17 8'-11" 2'-10" MAX. 2'-5" MIN. 3'-4" MAX.

WB3
M
L 17"-19"
WPT
B2
B 8'-11"
WPT TB-02
P
G
W
C 17"-19" 17"-19"
L
B2
D8'-11"
TB-02
G P
S
WB
M
TB-01
TB-02
WPT
C8'-11"
8" MIN. 3'-0" 3'-4" MAX. 2'-10" MAX. 2'-5" MAX.

N
G WB
M
TB-02
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640

TRANSPORTATION FACILITY REMODEL
INTERIOR ELEVATION NOTES #
NORTH

KEY PLAN
-2
Scale: 3/8" = 1'-0"
WOMEN'S RESTROOM - ELEVATION VIEW "D"
-3
Scale: 1/2" = 1'-0"
WOMEN'S RESTROOM - ELEVATION VIEW "A"
-5
Scale: 1/2" = 1'-0"
WOMEN'S RESTROOM - ELEVATION VIEW "C"
-4
Scale: 1/2" = 1'-0"
WOMEN'S RESTROOM - ELEVATION VIEW "B"
A
D B
C
WALL VIEWS | RESTROOMS A12.5
BUILDING 311
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.

AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.

AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.

WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.

FLOOR DRAIN, SEE PLUMBING SHEET.

BENCH
MIRROR, SEE SPECIFICATION.

COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.

NAPKIN DISPENSER

SOUP DISPENSER & COORDINATED FAUCET

SANITARY NAPKIN

PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.

WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.

GRAB BARS, SEE SPECIFICATION SHEET

BAG HOOK

PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH

SHOWER HEAD

SHOWER ROD

SHOWER CURTAIN

SHOWER SEAT
LOCKER

CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN

AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL

DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
NOTES:

1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. -1
Scale: 1/2" = 1'-0"
BUIDLING 311 @WOMEN'S RESTROOM - CONSTRUCTION PLAN

Page 1396 of 1646 ends

T
FC WB3
M
G
W
C
G
U
2 D
DR
TD SN
Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 C8'-0"
U
TB-02 17" MIN. MAX. 36"
TD
SN
D8'-0"
WB3
M
TB-02
8" MIN. 3'-0" 3'-4" MAX. 2'-10" MAX. 2'-5" MAX.

A2'-10" MAX. 2'-5" MIN. 3'-0" 3'-4" MAX.

W
G
C
FC
WB3
M
TB-02
TB-01 17"-19" 8'-0"
B8'-0"
G
W
C
TB-02 17" MIN. 17"-19"
U MAX. 36"
SN
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640

TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 1
NORTH

KEY PLAN
-4
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 1 - ELEVATION VIEW "A"
-2
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 1 - ELEVATION VIEW "B"
-5
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 1 - ELEVATION VIEW "D"
-3
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 1 - ELEVATION VIEW "C"
WALL VIEWS | RESTROOMS A12.6
BUILDING 311
INTERIOR ELEVATION NOTES #
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.

AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.

AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.

WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.

FLOOR DRAIN, SEE PLUMBING SHEET.

BENCH
MIRROR, SEE SPECIFICATION.

COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.

NAPKIN DISPENSER

SOUP DISPENSER & COORDINATED FAUCET

SANITARY NAPKIN

PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.

WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.

GRAB BARS, SEE SPECIFICATION SHEET

BAG HOOK

PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH

SHOWER HEAD

SHOWER ROD

SHOWER CURTAIN

SHOWER SEAT
LOCKER

CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN

AREA OF WORK
(N) WALL TO INSTALL
(N) TILE FLOORING TO INTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL

DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
A
D B
C
NOTES:

1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.

Page 1397 of 1646 ends

T
S
WB
M
W
C
G
G
DR
D
H Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 C8'-0"
G
W
C
TB-02 17"-19"
D8'-0"
8" MIN. 3'-0" 3'-4" MAX. 2'-10" MAX. 2'-5" MAX.

WB3
M
TB-02
W
G
C 17"-19"
A2'-10" MAX. 2'-5" MIN. 3'-4" MAX. 8'-0"
TB-01
TB-02
S
WB3
M
B 8'-0"
8" MIN. 3'-0" 3'-4" MAX. 2'-10" MAX. 2'-5" MAX.

WB3
M
TB-02
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640

TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 2
INTERIOR ELEVATION NOTES #
NORTH

KEY PLAN
-3
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 2 - ELEVATION VIEW "A"
-2
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 2 - ELEVATION VIEW "B"
-5
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 2 - ELEVATION VIEW "D"
-4
Scale: 1/2" = 1'-0"
UNISEX RESTROOM 2 - ELEVATION VIEW "C"
A
D B
C
WALL VIEWS | RESTROOMS A12.7
BUILDING 311
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.

AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.

AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.

WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.

FLOOR DRAIN, SEE PLUMBING SHEET.

BENCH
MIRROR, SEE SPECIFICATION.

COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.

NAPKIN DISPENSER

SOUP DISPENSER & COORDINATED FAUCET

SANITARY NAPKIN

PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.

WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.

GRAB BARS, SEE SPECIFICATION SHEET

BAG HOOK

PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH

SHOWER HEAD

SHOWER ROD

SHOWER CURTAIN

SHOWER SEAT
LOCKER

CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN

AREA OF WORK
(N) WALL TO INSTALL
(N) TILE FLOORING TO INTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL

DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
NOTES:

1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.

Page 1398 of 1646 ends

A13.0
- -
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640

TRANSPORTATION FACILITY REMODEL

WALL-MOUNTED

MULTIPLE

LAVATORY

ID NAME IMAGE DIMENSIONS MATERIAL/FINISH COLOR

EQUIPMENT SCHEDULE
LM1

AUTOMATIC
FLUSH
WATER
CLOSET
WC1
WT
HAND

HD DRYER
GRAB
GB BAR
REMARK

COORDINATED
FAUCET
and
SOAP

DISPENSER
FCS
WASTE

RECEPTACLE
and
PAPER
TOWEL

DISPENSER
WR
NeoMetro Stainless Steel -
White
36" LONG Stainless Steel
Stainless Steel 11-13/16” W X24-1/16” H
X2” D
Finish : Polished Nickel
Material : Diecast Zinc
Mounting Type : Counter Mounted
Operation : Automatic
Accessibility : ADA Compliant
Nichel And Chrome
Porcelain White UNIVERSAL

URINAL UR
WASTE
CHUTE
FOR

CONTERTOP
6-15/1/2” Diameter, 5” D Stainless Steel Silver
17-3/16” W X 56” H X
4” Min. D
Satin-finish Stainless Steel
6-1/6" Wx 5-15/16" Dx
11" H

AS SHOWN IN PLANS
Finish : Satin-Finish Stainless Steel
Mounting Options : Surface Mounted
Tissue Type : Standard Roll - Double
Accessibility : ADA Compliant
Finish : Satin-Finish Stainless Steel
Mounting Options : Counter Mounted
Features : Open Top
Finish : Satin-Finish Stainless Steel
Mounting Options : Recessed Mounted
Accessibility : ADA Compliant Silver
Silver
Silver
Silver
BAG
HOOK BH MAX. HEIGHT 48" Stainless Steel Silver -
-
Finish : Satin-Finish Stainless Steel
Mounting Options : Surface/Partition
Mounted (Single Sided)
Orientation : Vertical
Sanitary Disposal : Included
Configuration : Left Side of Toilet While
Seated
Stainless Steel Silver

TISSUE/ SEAT
COVER

DISPENSER/
WASTE

DISPOSAL
TSW Bobrick 26-5/8” W X12-5/8” H X 4” D
Finish : Satin-Finish Stainless Steel,
Satin-Finish Stainless Steel - Peened
Diameter : 1-1/4" (32mm)
Accessibility : ADA Compliant
30" LONG
American Standard 28-1/4”L X14” W X32-5/8” H Vitreous China Model: 3043.528.020 Flush Technology: HET High Efficiency
ADA Compliant
CA Drought Compliant
Approved for Commercial Use

WALL-MOUNTED

AUTOMATIC
FLUSH

WATER CLOSET
WC2 White American Standard
Model: 3351576.020 26”L X 14” W X 29-1/8” H Vitreous China Flush Technology: HET High Efficiency
ADA Compliant
CA Drought Compliant
Approved for Commercial Use
Water Sense Certified
American Standard
Model: 6002.001-B4.020
14-7/16"D X 14-5/16” W X
22 5/8” H
Flush Technology: HET High Efficiency
ADA Compliant
ANSI Certification
Approved for Commercial Use
CA Drought Compliant

WALL-MOUNTED
SINGLE

LAVATORY
LS1
Partition King
Model: Overhead Braced PER PLAN Hairline Stainless Steel Silver Finish : Hairline Stainless Steel
Mounting Options : Overhead Braced
Strength : Very Sturdy
Maintenance : Low Maintenance
Hardware : AOGAO Toilet Cubicle
Partition Hardware 08 Series

OVERHEAD
BRACED

RESTROOM

PARTITION
OP
Model: B-3091
Bobrick
Model: B-8879, B-8878
Koala Kare
Model: 310-54-KIT
Bobrick
Model: B-3944
Bobrick
Model: B-5806
Bobrick
Model: B-3725
Bobrick
Model: B-529
NeoMetro Stainless Steel -
ID NAME IMAGE MFG./MODEL DIMENSIONS MATERIAL/FINISH COLOR

EQUIPMENT SCHEDULE
REMARK
ADA Compliant
CA Drought Compliant
ASSE Certification
ASME Certification
CSA Certification
Water Efficient

SH SHOWER
HEAD
ARVO
COLLECTION Showerhead Height: 3.93"
Width: 3.31"
Polished Chrome -

RD SHOWER KOHLER
ROD
Expanse 60" - 72"
Adjustable Stainless Steel - -

SC SHOWER

CURTAIN
ULINE White
Microban additive resists mildew and
bacteria.

Stainless Steel tubing with Satin Finish
Square bow
ADA Compliant
ASME A112.18.1 Certification
CSA B125.1 Certification
cUPC Certification
LS

L-SHAPED

FOLDING
SHOWER
SEAT
ASI
Stainless Steel

COMPACT

FOLDING
SHOWER
SEAT
ASI Stainless Steel - CS

LK LOCKERS

FOREMAN
White Oak
PB Honey
ADA Compliant
LB

FINISH SCHEDULE
ID NAME IMAGE MFG. LOCATION MATERIAL COLOR
CF
WALL
PAINT
WPT
CPT

FINISH REMARK

CEILING
PAINT

CONCRETE
EPOXY

FLOORING
MODEL

CONCRETE CONCRETE

CRAFT STAINED

THROUGHOUT ALL
FLOORING, U.N.O
MATTE
EPOXY
LIGHT
- GRAY/
Per
Manufacture
Specification

SHERWIN

WILLIAMS

SHERWIN

WILLIAMS

THROUGHOUT

ALL THE
WALLS U.N.O

THROUGHOUT

ALL THE
CEILING U.N.O
-
-

WATER- BASED

WATER- BASED

EGGSHELL
FLAT

ALABASTER
SW 7008

PURE WHITE
SW 7005
1 Coat primer,
Paint as needed
to full cover

PT - PORCELAIN

FLOORING
TILE

DALTILE

THROUGHOUT

MAINTENANCE

BUILDING FLOORING

THOR BONE

BEIGE MATTE

POLCELAIN
TILE

POLCELAIN
MATTE

SUEDE GRAY

SPECKLE
DIM.
2" x 2"

GROUT JOINT
1/8"
COLORMATCHED
GROUT
FINISH
-
-
-
DWT
- THROUGHOUT

MAINTENANCE

BUILDING WALL
COLOR
WHEEL
LINEAR

CERAMIC
GLOSSY

BISCUIT GLOSSY
K175
8" x 24"

GROUT JOINT
1/16"
COLORMATCHED
GROUT
FINISH

THROUGHOUT

MAINTENANCE

BUILDING MATTE

GROUT JOINT
1/8"
COLORMATCHED
GROUT
FINISH
AWT 12 1/4" x 11 7/8"

AMERICAN
OLEAN

SERENTINA

BLOCK RANDOM

GLASS & STONE
MOSAIC

TRANQUILITY
SA94

DALTILE

DALTILE
EQUIPMENT & FINISH SCHEDULES |

RESTROOMS
42" LONG
DR1

SANITARY
SN NAPKIN Stainless Steel Silver
Finish : Satin-Finish Stainless Steel
Mounting Options : Surface Mounted
Capacity : 1.0-gal. (3/8-L)
Accessibility : ADA Compliant
7-1/2” W X 10” H X
3-13/16” D
Bobrick
Model: B-270
PAPER
TOWEL

DISPENSER
PT 14"L x 10.75"W Stainless Steel Silver
Finish : Satin-Finish Stainless Steel
Operation : Manual
Capacity : 400 C-fold; 525 multifold
Accessibility : ADA Compliant
Bobrick
Model: B-262

WALL-MOUNTED

MULTIPLE

LAVATORY
LM2 Truerform Porcelain Classic Per manufacture Specification Frame Finish: Matte Black
TYPE: LED Backlit
Glass Type: Standard
Accessibility: ADA Compliant
MR MIRROR 24” W X 36” H Stainless Steel Silver Bobrick
Model: B-167.MBLK
CUSTOM
MIRROR

MRC FULL HEIGHT
MIRROR
Frameless – Custom Size

WALL-MOUNTED
SINGLE

LAVATORY
LS2 Truerform Porcelain Classic Per manufacture Specification TD
TOILET
TISSUE
DISPENSER Stainless Steel Silver Bobrick
Model: B-2888
Stainless Steel Silver
1 Coat primer,
Paint as needed
to full cover
-

DOMINANT
WALL
TILE
ACCENT
WALL
TILE

1. ALL EQUIPMENT AND FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE CODES.

2. CONFIRM ALL EQUIPMENT LOCATIONS, CONNECTIONS, AND CLEARANCES WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS PRIOR TO INSTALLATION.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT OR FINISHES.

4. ALL FINISHES TO BE INSTALLED WITH UNIFORM COLOR, TEXTURE, AND PATTERN ALIGNMENT, AS PER APPROVED SAMPLE.

5. ALL MATERIALS SHALL BE NEW, OF COMMERCIAL GRADE, AND FREE OF DEFECTS.

6. SUBMITTALS FOR ALL FINISHES AND EQUIPMENT SHALL BE PROVIDED FOR ARCHITECT’S REVIEW AND APPROVAL PRIOR TO PROCUREMENT.

7. WHERE FINISHES TRANSITION BETWEEN MATERIALS OR COLORS, PROVIDE CLEAN, STRAIGHT LINES AND FINISH EDGES USING MANUFACTURER’S STANDARD TRIM UNLESS NOTED OTHERWISE.

8. ENSURE ALL EQUIPMENT IS FULLY OPERATIONAL AND TESTED PRIOR TO FINAL INSPECTION.

REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.

EQUIPMENT AND FINISH GENERAL NOTES
Model: 8981
Model: 8981
Square bow
ADA Compliant
ASME A112.18.1 Certification
CSA B125.1 Certification
cUPC Certification

AS SHOWN IN PLANS

AS SHOWN IN PLANS

AS SHOWN IN PLANS
Model: 142840-I
Model: K-9351-SN
MFG./MODEL
Model: S-25181
S-25182
AS SHOWN IN PLANS PVC Vinyl
Model: 10-8206-R
10-8206-L

AS SHOWN IN PLANS -
Frame color family: Silver
Seat color family: White
Frame color family: Silver
Seat color family: White
Model: 10-8203 AS SHOWN IN PLANS
Model: SIGNATURE

LOCKERS WITH

AND WITHOUT
SEAT
6063 T6 Aluminum
profile and solid
phenolic walls

PER MANUFACTURE

SHOP DRAWING
Bobrick
Model: B-165
DR
FLOOR
DRAIN
LINEAR
SHOWER
DRAIN
Accessibility : ADA Compliant
Finish : Satin-Finish Stainless Steel
Operating: manual
Mounting Options : Recessed Mounted
Paper Type: Multi-Fold Towel
Towel Capacity : 600 C-fold; 600
Multifold
Waste Capacity : 12-gal.

VIGO
Model: VG07004BN 4-3/8" W Brushed Nickel Silver
Finish: Brushed Nickel
Accessibility : ADA Compliant
UPC Certification

SIGNATURE

HARDWARE
Model: 443342
Stainless Steel Silver
Finish: Brushed Stainless Steel
Features a Removable Hair Strainer
Basket AS SHOWN IN PLANS

ELKAYINTERIOR
SYSTEM

BUILT-IN
LOCKER
ROOM
BENCH
AS SHOWN IN PLANS Hardwood White Oak ADA Compliant PB Honey LK1 WALLET

LOCKERS

FOREMAN
White Oak
PB Honey Model: Wallet- Phone ADA Compliant
- Lockers
6063 T6 Aluminum
profile and solid
phenolic walls

PER MANUFACTURE

SHOP DRAWING

LB BENCH

LOCKERS
Model: Salbury Wood
Locker Bench
Height:18"
Width: 36"
Depth: 9 1
2 " Wood Light Bench ADA Compliant

Page 1399 of 1646 ends

MECHANICAL SHEET INDEX
SHEET NO. SHEET NAME SCALE
M0.0 MECHANICAL GENERAL NOTES AND SYMBOLS N.T.S.

SR NO.
1 3
4 6
M1.0 3/16" = 1'-0"
N.T.S.
5 MECHANICAL SYMBOLS
SWS SIDE WALL SUPPLY GRILLE
SWR SIDE WALL RETURN/EXHAUST GRILLE
EXISTING DUCT TO REMAIN
DUCT
DUCT TRANSITION
MVD MANUAL VOLUME DAMPER
FD AUTOMATIC FIRE DAMPER
CSFD COMBINATION SMOKE/FIRE DAMPER
UP DUCT OFFSET UP
DUCT OR EQUIPMENT TO BE REMOVED
PRESSURE REDUCING VALVE
ISOLATION VALVE (BALL)
ISOLATION VALVE (BUTTERFLY)
MOTORIZED CONTROL VALVE
CHECK VALVE

THERMOMETER
PRESSURE GAUGE
DUCT SMOKE DETECTOR
POINT OF DISCONNECT
POINT OF CONNECTION
/
TC TIME CLOCK
SWITCH

1.0 DL
UC UNDER CUT DOOR
TYPICAL AIR DEVICE DESIGNATION
POC
POD
CO2
U
C
P
BDD BACKDRAFT DAMPER
BDD
EXISTING DUCTWORK M
T TS
ON CENTER
RETURN AIR
SHEET METAL SCREW
TRANSFER GRILLE
POUNDS PER SQUARE INCH
OUTSIDE AIR
AIR CONDITIONER
ABOVE FINISH FLOOR
ACCESS PANEL
CUBIC FEET PER MINUTE
GALLONS PER MINUTE
GALVANIZED IRON
DIRECT EXPANSION
BACKDRAFT DAMPER
BRITISH THERMAL UNITS PER HOUR
DX

FLR FLOOR
FOOT, FEET
GPM
GI
-  G  -
FT

EXISTING
-  F  -
-  E  -
(E)
DOWN

DRAWING
-  D  -
DN
DWG
-  C  -
CFM

BLDG BUILDING
BTUH
BDD
-  B  -
AFF
AP
-  A  -
A/C
OSA
NORMALLY OPEN
NORMALLY CLOSED
NOT TO SCALE
NOT IN CONTRACT
NATURAL GAS

MECHANICAL
1000 BRITISH THERMAL UNITS PER HOUR
MACHINE BOLT
HOT WATER
HEATING VENTILATING AND AIR CONDITIONING
NG
NO
NC
NTS
NIC
-  N  -
MIN
MTD
MECH

MINIMUM

MOUNTED
MBH
MB
MAX
LAT

MAXIMUM
LEAVING AIR TEMPERATURE
-  M  -
-  K  -
KW
HW
HVAC

KILOWATT
-  U  -
TG

TYP TYPICAL
-  S  -
-  T  -
SMS
SQ
RA
SQUARE
-  P  -
-  R  -
PH
PSI
PHASE

HORSEPOWER
MECHANICAL ABBREVIATIONS
HP
-  O  -
OC
-  H  -
AFUE ANNUAL FUEL UTILIZATION EFFICIENCY

ABV ABOVE

BEL BELOW
EER ENERGY EFFICIENCY RATIO
EA EXHAUST AIR

HZ HERTZ
MCA MINIMUM CIRCUIT AMPACITY
MOCP MAXIMUM OVERCURRENT PROTECTION
NPS NOMINAL PIPE SIZE

OPER OPERATING
S.P. STATIC PRESSURE
TDH TOTAL DYNAMIC HEAD
-  W  -

WT WEIGHT
(L) LINED DUCT
S/S STAINLESS STEEL
AI
AO ANALOG OUTPUT
ANALOG INPUT

COMP COMPRESSOR
DI
DO
DDC
DIGITAL INPUT
DIGITAL OUTPUT
DIRECT DIGITAL CONTROL
MA MIXED AIR
EAT ENTERING AIR TEMPERATURE

EQUIP EQUIPMENT
MS MOTOR STARTER
OA OUTSIDE AIR
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SF SUPPLY FAN
-  V  -
VAC VOLTS ALTERNATING CURRENT
VFD VARIABLE FREQUENCY DRIVE

W/ WITH
CO CARBON MONOXIDE

LB POUND
LWT LEAVING WATER TEMPERATURE
-  I  -
IN. INCHES

HR HOUR
FPI FINS PER INCH
EMS ENERGY MANAGEMENT SYSTEM
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE

EFF EFFICIENCY
-  L  -

SYM SYMBOL

SENS SENSIBLE
-  Q  -

QTY QUANTITY
P.D. PRESSURE DROP
ODP OUTDOOR DRIP PROOF
NC NOISE CRITERIA

MFR MANUFACTURER
CD CEILING DIFFUSER
EG EXHAUST GRILLE
RG RETURN GRILLE
SWR SIDEWALL RETURN GRILLE
SWS SIDEWALL SUPPLY GRILLE
RAD RETURN AIR DUCT
SAD SUPPLY AIR DUCT
DTR DOWN THRU ROOF

CONT CONTINUATION
UNO UNLESS NOTED OTHERWISE
UTR UP THRU ROOF
EAD EXHAUST AIR DUCT

GA GAUGE
DWD DOUBLE WALL DUCT
RL REFRIGERATION LIQUID
RS REFRIGERATION SUCTION

DEG DEGREE

DIA DIAMETER

TSTAT THERMOSTAT
SOV SHUT OFF VALVE
FAI FRESH AIR INTAKE
U
C
SUPPLY DIFFUSER
EXHAUST REGISTER / GRILLE
RETURN GRILLE
SUPPLY RISER UP THROUGH STRUCTURE
RETURN RISER UP THROUGH STRUCTURE
EXHAUST RISER UP THROUGH STRUCTURE
SUPPLY RISER DOWN
RETURN RISER DOWN
EXHAUST RISER DOWN
(E)
TYPICAL EQUIPMENT DESIGNATION
S
SA
RA
EXH
BEX
OA
SA SUPPLY AIR DUCT
RA RETURN AIR DUCT
BEX BATHROOM EXHAUST DUCT
OA OUTDOOR AIR DUCT
EXH EXHAUST DUCT
RF REFRIGERANT PIPING
CD CONDENSATE DRAIN
CASEWORK OR OTHER OBSTRUCTION
MOTORIZED DAMPER
THERMOSTAT / SENSOR. MOUNT
@ +48" AFF (IF MOUNTED OVER
46" TO TOP OF DEVICE).

CARBON DIOXIDE SENSOR FOR
OUTSIDE AIR MODULATION
DOOR LOUVER W/ MINIMUM
FREE AREA (SQ. FT.)

1. ALL MECHANICAL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND STANDARDS.

2. THE ENTIRE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE 2022 CALIFORNIA MECHANICAL CODE WITH CITY OF LOS ANGELES AMENDMENTS, 2022 CALIFORNIA BUILDING CODE WITH CITY OF LOS ANGELES AMENDMENTS, AND OTHER APPLICABLE CODES AND REGULATIONS, INCLUDING 2022 CALIFORNIA ENERGY EFFICIENCY STANDARDS (TITLE 24, PART 6), AND CAL-GREEN REQUIREMENTS WITH LA CITY AMENDMENTS.

3. PRIOR TO SUBMITTING BID, CONTRACTOR SHALL SURVEY THE ENTIRE PROJECT SITE AND BECOME THOROUGHLY FAMILIAR WITH ACTUAL EXISTING CONDITIONS. THE INTENT OF WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED HEREIN. BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK, THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE SUCH A STUDY AND EXAMINATION AND TO ACCEPT ALL CONDITIONS PRESENT AT SITE. NO REQUEST FOR ADDITIONAL PAYMENT SHALL BE CONSIDERED VALID, DUE TO CONTRACTOR FAILURE TO ALLOW IN COST ESTIMATE FOR CONDITIONS WHICH MAY EXIST.

4. CONTRACTOR MUST VERIFY LOCATIONS OF ALL EQUIPMENT AND POINTS OF CONNECTIONS AND COORDINATE WITH THE CONSTRUCTION MANAGER, ARCHITECT, MEP ENGINEERS AND UTILITY CONSULTANTS PRIOR TO START OF CONSTRUCTION. NO COMPENSATION WILL BE MADE FOR RELOCATION OF EQUIPMENT AND ASSOCIATED COST.

5. CONTRACT DRAWINGS ARE DIAGRAMMATIC. THE CONTRACTOR MUST FILED VERIFY THE DRAWINGS PRIOR TO FABRICATION AND CONSTRUCTION. ALL DIMENSIONS SHOWN ON THESE PLANS ARE APPROX AND MUST BE CONFIRMEND ON SITE.

6. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED, AND SEALED IN ACCORDANCE WITH THE MOST RESTRICTIVE OF LOCAL, REGULATIONS AND PROCEDURES DETAILED IN ASHRAE HANDBOOK OF FUNDAMENTALS OR THE APPLICABLE STANDARD ADOPTED BY THE SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION AND THE UNIFORM MECHANICAL CODE.

7. ALL DUCT SIZES ARE CLEAR INSIDE SIZES. OBTAIN APPROVAL FROM CONSTRUCTION MANAGER FOR SIZING OF ANY DUCTWORK WHERE SIZES ARE NOT SHOWN ON DRAWINGS.

8.  MANUAL VOLUME DAMPERS SHALL BE PROVIDED IN ALL DUCT BRANCHES TO INDIVIDUAL BOXES, DIFFUSER, GRILLES & REGISTERS AND SHALL BE LOCKED IN THE FINAL POSITION AFTER COMPLETION OF AIR-BALANCE.

9.  PROVIDE ANCHORAGE FOR ALL PIPING, DUCTWORK AND EQUIPMENT IN ACCORDANCE WITH THE  LATEST EDITION OF GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEM AND PLUMBING PIPING SYSTEM PER SMACNA.

10.  NSTALL 1" THICK DUCT BOARD FOR SUPPLY AND RETURN AIR DUCT IF INDICATED IN THE DRAWINGS.

11.  ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE EQUIPMENT MANUFACTURERS RECOMMENDATIONS. PROVIDE ALL NECESSARY ACCESSORIES FOR COMPLETE INSTALLATION.

12. PRE INSULATED FLEXIBLE DUCTWORK SHALL BE SUPPORTED AND JOINED TO SHEET METAL PER SMACNA DUCT CONSTRUCTION STANDARDS AND SHALL BE USED WITH A 2" SHEET METAL SADDLE AT EACH SUPPORT HANGER.

13. WHEN FLEXIBLE DUCTWORK IS INSTALLED AS A BRANCH DUCTWORK TO A SHEET METAL ELBOWS WITH AN ALUMINIZED INSULATION MATCHING THE PRE-INSULATIED FLEXIBLE DUCTWORK INSULATING VALUE.

14. ALL HVAC EQUIPMENT SHALL BE U.L. LISTED AND BEAR A U.L. LABELS.

15. MECHANICAL EQUIPMENT, AIR DISTRIBUTION DEVICES, AIR DIFFUSERS, FANS AND OTHER EQUIPMENT THAT MAY PROJECT SOUND SHALL BE INSTALLED PER MINIMUM REQUIREMENT. CONFORM TO INSTALLATION DETAILS AND RECOMMENDATION IN CHAPTER 52 OF ASHRAE HANDBOOK, "HVAC SYSTEM AND APPLICATIONS."

16. CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS AT THE END OF THE PROJECT IN CAD AND/OR REVIT AND PDF AS PART OF PROJECT CLOSURE.

17.  COORDINATE THE THERMOSTATS/SENSORS LOCATIONS WITH THE ARCHITECT. ALL THE THERMOSTATS/SENSORS SHALL BE MOUNTED AT 48" ABOVE FINISHED FLOOR TO MEET ADA REQUIREMENTS.

18. FURNISH AND INSTALL ALL DUCTWORK INDICATED ON DRAWINGS. ALL DUCTWORK SHALL BE GALVANIZED STEEL, CONFORMING TO ASTM A527 WITH CLASS D COATING IN STANDARD SHEETS, FABRICATED AND INSTALLED IN FULL COMPLIANCE WITH THE CALIFORNIA MECHANICAL CODE. DUCTS AND FITTINGS SHALL BE IN ACCORDANCE WITH THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS.

19. CONTRACTOR SHALL REFURBISH THE EXISTING EQUIPMENT NOTED TO BE REUSED FOR LIKE NEW CONDITIONS AND SHALL INFORM THE CLIENT/ARCHITECT/ENGINEER IF ANY OF THE EQUIPMENT IS MALFUNCTIONING AND HAS TO BE REPLACED

20. MECHANICAL CONTRACTOR SHALL BALANCE SYSTEM TO AIR QUANTITIES INDICATED ON PLANS AND PROVIDE A COMPLETE BALANCING REPORT IN ACCORDANCE WITH NEBB OR AABC STANDARDS.

21. ALL DUCT SHALL BE INSULATED PER SECTION 120.4(a) OF 2022 BUILDING ENERGY EFFICIENCY STANDARDS.

22. DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL IN ACCORDANCEW/ CHAPTER 6 OF THE CALIFORNIA MECHANICAL CODE. SUSPENSION SHALL CONFORM TO 006-2006 SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND WATERTIGHT. FLEXIBLE ALUMINUM DUCT WORK IS NOT ALLOWED, DUCT TAPE IS NOT ALLOWED.

23. THE DUCT ROUTING SHOWN ON PLANS ARE SCHEMATIC ONLY, VERIFY WITH STRUCTURAL AND ALL OTHER PARTIES REGARDING ANY DISCREPANCY AND REPORT TO THE MECHANICAL ENGINEER FOR APPROVAL.

24. REFER TO THE ARCHITECTURAL DRAWINGS FOR FINALIZED CEILING HEIGHTS.

25. FIRE SEAL ALL THE PENETRATIONS AS REQUIRED PER  IMC CODE REQUIREMENTS.

26. ENVIRONMENTAL AIR DUCTS SHALL NOT TERMINATE LESS THAN 3' TO A PROPERTY LINE, 10' TO A FORCED AIR INLET, 3' TO OPENINGS INTO THE BUILDING AND SHALL NOT DISCHARGE ON TO A PUBLIC WAY.

27. SUPPLY-AIR AND RETURN-AIR DUCTS CONVEYING HEATED OR COOLED AIR SHALL BE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-4.2 (R-8 IF INSTALLED IN AN UNCONDITIONED SPACE) UNLESS DUCTS ARE IN CONDITIONED SPACE OR NOTED OTHERWISE.

28. PRIOR TO COMMENCING ANY WORK, CONTRACTOR SHALL SURVEY AND FIELD VERIFY ALL MECHANICAL SERVICES CROSSING THE LINE OF DEMOLITION AND EXACT POINTS OF DISCONNECT AND CONNECTION.

29. PRIOR TO ALL DEMOLITION WORK, VERIFY ALL EXISTING CONDITIONS AND MARKUP ANY DEVIATION FROM AVAILABLE AS-BUILT DRAWINGS.

30. PRIOR TO DEMOLITION WORK, IDENTIFY OPERATIONAL IMPACTS AND SUBMIT A REPORT TO OWNER FOR REVIEW AND APPROVAL. THIS REPORT SHALL INCLUDE DETAILS OF ALL SYSTEMS IMPACTED BY THE DEMOLITION WORK, ANTICIPATED DURATION OF DEMOLITION WORK, DETAILED PLANS OF HOW TO BRING SYSTEMS BACK ONLINE, AND OTHER RELEVANT INFORMATION AS APPROPRIATE.

31. CONTRACTOR SHALL PROVIDE DUST COVERS AS REQUIRED TO CONTAIN DUST AND DEBRIS WITHIN CONSTRUCTION AREA AND KEEP DIRT AND DUST TO A MINIMUM.

32. MECHANICAL CONTRACTOR SHALL INCLUDE PRICING ALLOWANCE FOR ADDITIONAL OFFSETS AND ELBOWS NOT SHOWN ON THE DRAWINGS (AS NEEDED BASED ON FINAL COORDINATED CONTRACTOR MODEL).

33. SCHEDULE ALL WORK WITH THE FACILITY INCLUDING CONSTRUCTION ACCESS AND STORAGE. THE CONSTRUCTION SCHEDULE PROCEDURE SHALL BE APPROVED BY THE FACILITY PRIOR TO THE START OF CONSTRUCTION.

34. ALL UTILITIES REQUIRED FOR THE CONTINUOUS OPERATION OF ALL EXISTING FACILITIES MUST BE MAINTAINED IN SERVICE AT ALL TIMES EXCEPT AS REQUIRED FOR NEW SYSTEMS CONNECTION.

COORDINATE SHUTDOWN WITH RESPONSIBLE FACILITY PERSONNEL.

35. CONTRACTOR SHALL PERFORM PRE-READS ON THE AIR-SIDE MECHANICAL SYSTEMS IMPACTED BY THE DEMOLITION SCOPE PRIOR TO START OF CONSTRUCTION AND SUBMIT FOR EOR REVIEW. CONTRACTOR SHALL FIELD VERIFY ALL SYSTEMS WITHIN THE DEMOLITION AREA AND CONFIRM THAT THE DEMOLITION DOESN'T IMPACT THE REMAINING SPACES. SUBMIT THE PRE-READ REPORT FOR MEOR REVIEW PRIOR TO START OF ANY DEMOLITION WORK.

36. CONTRACTOR SHALL CAP AND SEAL ALL DUCTWORK IN ACCORDANCE WITH SMACNA. EXACT POINT OF CONNECTIONS AND DEMOLITION SHALL BE VERIFIED BY TRADE PARTNERS PRIOR TO START OF CONSTRUCTION.

AFTER DEMOLITION IS COMPLETE, THE REMAINING SPACES SHALL BE REBALANCED TO THE APPROVED VALUES THAT WERE OBTAINED DURING PRE-READS.

37. ALL ELECTRICAL WIRING AND CONDUIT SERVING MECHANICAL AND PLUMBING EQUIPMENT SHALL BE DEMOLISHED TO THE CIRCUIT BREAKER SERVING IT AND THE CIRCUIT BREAKER SHALL BE IDENTIFIED AS SPARE. COORDINATE WITH ELECTRICAL CONTRACTOR.

38. PRIOR TO COMMENCING ANY WORK, CONTRACTOR SHALL SURVEY AND FIELD VERIFY ALL MECHANICAL SERVICES CROSSING THE LINE OF DEMOLITION AND EXACT POINTS OF DISCONNECT AND CONNECTION.

39. PRIOR TO ALL DEMOLITION WORK, VERIFY ALL EXISTING CONDITIONS AND MARKUP ANY DEVIATION FROM AVAILABLE AS-BUILT DRAWINGS.

40. PRIOR TO DEMOLITION WORK, IDENTIFY OPERATIONAL IMPACTS AND SUBMIT A REPORT TO OWNER FOR REVIEW AND APPROVAL. THIS REPORT SHALL INCLUDE DETAILS OF ALL SYSTEMS IMPACTED BY THE DEMOLITION WORK, ANTICIPATED DURATION OF DEMOLITION WORK, DETAILED PLANS OF HOW TO BRING SYSTEMS BACK ONLINE, AND OTHER RELEVANT INFORMATION AS APPROPRIATE.

41. CONTRACTOR SHALL CREATE METHOD OF PROCEDURE (MOP) AND SUBMIT TO MEOR AND OWNER FOR APPROVAL PRIOR TO COMMENCEMENT OF ANY WORK.

42. ALL CONTROL SYSTEMS SERVING THE DEMOLITION AREA SHALL BE REMOVED AND THE AREAS REMAINING SHALL BE VERIFIED BY THE CONTRACTOR TO BE FUNCTIONAL.

43. FLEXIBLE DUCTS SHALL BE SUPPORTED AT OR NEAR MID-LENGTH WITH 2" WIDE 28 GA. STEEL HANGER COLLAR ATTACHED TO THE STRUCTURE WITH AN APPROVED DUCT HANGER. INSTALLATION SHALL MINIMIZE SHARP RADIUS TURNS OR OFFSETS. 5' MAXIMUM LENGTH CONNECTING TO TERMINAL OUTLETS.

44. PROVIDE BACKDRAFT DAMPERS AT ALL EXHAUST AND FRESH AIR INTAKES.

45. PROVIDE WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND/OR LABOR, AT NO COST TO OWNER, FOR A PERIOD OF ONE YEAR FROM DATE OF OWNER ACCEPTANCE. PROVIDE 5 YEAR COMPRESSOR WARRANTY AND 10 YEAR HEAT EXCHANGER WARRANTY FOR ALL A/C EQUIPMENT.

46. UNLESS SPECIFICALLY SHOWN ON THESE PLANS, NO STRUCTURAL MEMBERS SHALL BE CUT, DRILLED, NOR NOTCHED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE STRUCTURAL ENGINEER AND THE DISTRICT STRUCTURAL ENGINEER FROM THE DIVISION OF THE STATE ARCHITECT.

47. ALL DUCT SIZES SHOWN ARE NET INSIDE DIMENSIONS AND DO NOT ACCOUNT FOR DUCT LINER THICKNESS WHERE APPLICABLE. ALL PIPE DIMENSIONS SHOWN ARE NOMINAL SIZES.

48. ALL BRANCH DUCTS SHALL BE PROVIDED WITH ACCESSIBLE MANUAL VOLUME DAMPERS.

49. INSTALLATION & MATERIALS SHALL CONFORM TO THE 2022 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC) AND TITLE 24 PARTS 4 & 6. 18.  CONTRACTOR SHALL PROVIDE AS-BUILTS, CAD GENERATED AND DRAWN TO 1/8" = 1'-0" SCALE.  SUBMIT 6 SETS OF HARD COPIES AND 1 ELECTRONIC COPY ON CD-ROM. CAD DRAWINGS SHALL BE AUTOCAD, LATEST VERSION.  COORDINATE REQUIREMENTS WITH OWNER.

FU
1 AIRFLOW
(CFM)
TYPE TAG
S-250-A
10"X6"
M1.1
M1.2
M1.3
7 8
3/16" = 1'-0"
3/16" = 1'-0"
3/16" = 1'-0"
M6.0 MECHANICAL SCHEDULES N.T.S.
11 M5.0 MECHANICAL DETAILS
1/4" = 1'-0"
ADMINISTRATION BUILDING : MECHANICAL 1ST FLOOR DEMO PLAN ADMINISTRATION BUILDING : MECHANICAL 2ND FLOOR DEMO PLAN ADMINISTRATION BUILDING : MECHANICAL 1ST FLOOR PROPOSED PLAN ADMINISTRATION BUILDING : MECHANICAL 2ND FLOOR PROPOSED PLAN MAINTENANCE BUILDING : 1ST & 2ND FLOOR DEMOLITION PLAN
MAINTENANCE BUILDING : 1ST & 2ND FLOOR PROPOSED PLAN
311 BUILDING : DEMOLITION RESTROOM FLOOR PLAN
GYM RESTROOM AND FUEL ISLAND BUILDING : MECHANICAL DEMOLITION & PROPOSED PLAN M1.5
9 M1.7
M1.4 1/4" = 1'-0"
M1.8
12 X
311 BUILDING : PROPOSED RESTROOM RCP PLAN
M1.6
10 3/8" = 1'-0"
3/8" = 1'-0"
3/8" = 1'-0"
GENERAL NOTES
OUTDOOR AIR DUCT
SA FLEX DUCT
CALIFORNIA CODES AND STANDARDS

1. 2022 CALIFORNIA BUILDING CODE

2. 2022 CALIFORNIA ELECTRICAL CODE

3. 2022 CALIFORNIA MECHANICAL CODE

4. 2022 CALIFORNIA PLUMBING CODE

5. 2022 CALIFORNIA RESIDENTIAL CODE

6. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
2 MECHANICAL GENERAL NOTES AND SYMBOLS
M0.0
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1400 of 1646 ends

DISPATCH

VESTIBULE
MEN
WOMEN

VENDING QUIET WOMEN
MEN
CORR.

TRAINING
ROOM

TRAINING
ROOM

STORAGE
CLOSET
ASSIST.

TRANSIT
COORD

CONFERENCE DISPATCH
TRANS.

SUPV.

TRANS.

MGR.

SECRETARY

KITCHEN
PANTRY

RECEPTION
LIFT
DRIVERS LOUNGE
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
XX
X
X
X
X
XX
X
X
X X
X
X
X
X
X
X X
X
X
X
X
X
XX
X
X
X
(E)24"X16"SA
(E)16"X8"SA
(E)20"X10"SA
(E)16"X10"SA
(E)34"X10"SA
(E)16"X12"SA
(E)20"X10"SA
(E)20"X16"SA
(E)24"X12"
(E)36"X18"SA
(E)36"X18"RA
(E)18"x8"
(E)14"x10"
(E)18"x8"
(E)18"x18"
(E)18"X8"
(E)16"X8"
(E)14"X6"
(E)36"X18"RA
(E)36"X18"SA
(E)36"x14"SA
6"X14"
(E)14"X12"SA
(E)12"X6"SA
(E)12"X6"SA
(E)18"X8"
(E)18"X8"
(E)18"X8"
(E)12"X6"
DEMO GENERAL NOTE:

A. ALL  DEMOLITION  OF  THE  HVAC  SYSTEM  AS  CALLED
FOR  ON  THE  DEMOLITION  DRAWINGS  SHALL  BE
UNDER  THE  MECHANICAL  (HVAC)  CONTRACTORS
WORK.

B. BEFORE  STARTING  ANY  DEMOLITION  ON  HVAC
EQUIPMENT  WHICH  HAS  AN  ELECTRICAL
CONNECTION, THE MECHANICAL CONTRACTOR SHALL
MEET  WITH  THE  ELECTRICAL  CONTRACTOR  TO
IDENTIFY  ALL  SUCH  EQUIPMENT.  THE  ELECTRICAL
CONTRACTOR  WILL  DISCONNECT  THE  POWER  TO
EACH UNIT, REMOVE CONDUIT, WIRING, DISCONNECT
SWITCHES  AND  STARTERS  UNDER  HIS  CONTRACT.

MECHANICAL  CONTRACTOR  WILL  REMOVE  ALL
EQUIPMENT,  ELECTRIC  TEMPERATURE  CONTROL
WIRING AND CONDUIT UNDER THIS CONTRACT.

C. CAP  AND  SEAL  AT  POINT  OF  DISCONNECT  TO
MAINTAIN THE AIRFLOW IN THE SPACES OUTSIDE OF
THE PROJECT SCOPE.

D. ALL  EQUIPMENT,  MATERIAL,  ETC.  THAT  IS  BEING
DEMOLISHED  WILL  BECOME  THE  PROPERTY  OF  THE
MECHANICAL CONTRACTOR. ALL SUCH ITEMS WILL BE
REMOVED  FROM  THE  BUILDING  SITE  BY  THE
MECHANICAL CONTRACTOR. NO ITEM WHICH IS BEING
REMOVED  UNDER  THE  DEMOLITION  CONTRACT  MAY
BE REUSED UNDER THE NEW WORK CONTRACT.

E. SEQUENCE  OF  ALL  DEMOLITION  WORK  SHALL  BE  IN
STRICT  ACCORDANCE  WITH  THE  DRAWINGS  AND/OR
AS DIRECTED BY ARCHITECT/ENGINEER.

F. THE  CONTRACTOR  PERFORMING  THE  DEMOLITION
WORK  SHALL  REMOVE  NO  MORE  THAN  8"  OF
BUILDING  MATERIAL  AROUND  EACH  DEVICE  BEING
DEMOLISHED.

G. NOT  ALL  AREAS  MAY  HAVE  BEEN  AVAILABLE  FOR
SURVEY  DURING  DESIGN.  THE  CONTRACTOR  SHALL
THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE
OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS
IN  QUESTION  OR  THAT  COULD  NOT  BE  OBSERVED
SHALL  BE  OUTLINED  IN  THE  CONTRACTORS  BID.

ADDITIONAL  COMPENSATION  FOR  FAILURE  TO  FIELD
VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS  WILL  NOT  BE  APPROVED.  EXISTING  SYSTEMS
ARE  SHOWN  BASED  ON  VISUAL  INSPECTION  AND
AS-BUILT/DESIGNED  DOCUMENTS  AND  MAY  NOT
REFLECT ACTUAL CONDITIONS.

H. ALL  LOCATIONS  SHOWN  ON  THESE  DRAWINGS  ARE
APPROXIMATE. VERIFY EXACT LOCATIONS IN FIELD.

I. THE  DEVICES  AND  EQUIPMENT  INDICATED  BY
DEMOLITION  SYMBOLS  ON  THE  PLANS  ARE  NOT
NECESSARILY THE LIMITS OF THE WORK INVOLVED IN
THE  RENOVATION.  THE  CONTRACTOR  SHALL
CAREFULLY  EXAMINE  THE  COMPLETE  SET  OF
ENGINEER  &  ARCHITECTURAL  PLANS  FOR  ALL
TRADES  AND  PERFORM  A  DETAILED  FIELD  SURVEY
DURING THE BIDDING PERIOD TO ENSURE THAT THE
ENTIRE  SCOPE  OF  WORK  INVOLVED  IS  INCLUDED  IN
THE BID PRICE.
(E)26"x18"(E)26"x18"
(E)36"X18"SA
DEMO KEYNOTE:

1. CONTRACTOR TO DEMOLISH THE HIGHLIGHTED EXISTING
DUCTWORK AND DIFFUSER OR GRILLE.

2. REMOVE  EXISTING  DIFFUSER  AND  ASSOCIATED
DUCTWORK.  CAP  AND  SEAL  THE  REMAINING  DUCT
BRANCH FOR FUTURE CONNECTION.

SCOPE OF WORK

LEGENDS
X
X
X
X
XX
DEMOLISH EXISTING DIFFUSER/GRILLE
AND DUCTWORK
SCOPE OF WORK LIMIT
2 2
2 2 1
1 1
1 1
1 2
2 2
2 2
2 2
1 1
1 1
1 1
1 1
1 1
2 1
NORTH
SCALE:

ADMINISTRATION BUILDING: MECHANICAL 1ST FLOOR DEMO PLAN 1 3/16" = 1'-0" M1.0
ADMINISTRATION BUILDING: MECHANICAL 2ND
FLOOR DEMO PLAN
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1401 of 1646 ends

LIFT

WAITING
ADMIN SEC. PLANNING SPECIAL SPECIAL ASSIST. DIR. ACCT. SUPV.

CORR.

CONFERENCE TRANSIT DIR.

LOUNGE ROOF DECK COPY WORK OFFICE
CLERKS
CRC ASLE
ELECT ROOM
MECH. SHAFT

MEN AUDIT
WOMEN
STAIR

ARCHIVES
X
X
X
XXX
X
X
X
X
X
X

X X X X X X XX
X
X X X
X X X

X X X X X X X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
XX
XX
XX
XX
X
X

XXX XXX XXX XXX XXX XXX XXX

X X X X X X X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
XX
XX
X
X
XX
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
XX
X
X
X
X
X
XX
X
X
X X X
XX
X
X
X
X
X
X XX
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
XXX
X
X
X
X
X
X
X
X
X
X
X
X
X X
(E)8"ØSA
(E)10"X10"SA
(E)20"X8"SA
(E)12"X12"
12"X6"SA
(E)12"X8"SA
(E)14"X12"
(N)8"ØSA
(E)10"ØSA
(E)36"x18"RA
22"X10"DN 18"X18"UP
(E)10"ØSA
(E)10"ØSA
(E)18"X12"SA
(E)6"Ø
(E)6"Ø
(N)10"ØEA
(E)10"X8"SA
(E)7"Ø
(E)36"x18"SA
(E)10"ØSA
(E)6"Ø
(E)16"X8"SA
(E)12"X6"SA
(E)12"X12"
SCOPE OF WORK
DEMO GENERAL NOTE:

A. ALL  DEMOLITION  OF  THE  HVAC  SYSTEM  AS  CALLED
FOR  ON  THE  DEMOLITION  DRAWINGS  SHALL  BE
UNDER  THE  MECHANICAL  (HVAC)  CONTRACTORS
WORK.

B. BEFORE  STARTING  ANY  DEMOLITION  ON  HVAC
EQUIPMENT  WHICH  HAS  AN  ELECTRICAL
CONNECTION, THE MECHANICAL CONTRACTOR SHALL
MEET  WITH  THE  ELECTRICAL  CONTRACTOR  TO
IDENTIFY  ALL  SUCH  EQUIPMENT.  THE  ELECTRICAL
CONTRACTOR  WILL  DISCONNECT  THE  POWER  TO
EACH UNIT, REMOVE CONDUIT, WIRING, DISCONNECT
SWITCHES  AND  STARTERS  UNDER  HIS  CONTRACT.

MECHANICAL  CONTRACTOR  WILL  REMOVE  ALL
EQUIPMENT,  ELECTRIC  TEMPERATURE  CONTROL
WIRING AND CONDUIT UNDER THIS CONTRACT.

C. CAP  AND  SEAL  AT  POINT  OF  DISCONNECT  TO
MAINTAIN THE AIRFLOW IN THE SPACES OUTSIDE OF
THE PROJECT SCOPE.

D. ALL  EQUIPMENT,  MATERIAL,  ETC.  THAT  IS  BEING
DEMOLISHED  WILL  BECOME  THE  PROPERTY  OF  THE
MECHANICAL CONTRACTOR. ALL SUCH ITEMS WILL BE
REMOVED  FROM  THE  BUILDING  SITE  BY  THE
MECHANICAL CONTRACTOR. NO ITEM WHICH IS BEING
REMOVED  UNDER  THE  DEMOLITION  CONTRACT  MAY
BE REUSED UNDER THE NEW WORK CONTRACT.

E. SEQUENCE  OF  ALL  DEMOLITION  WORK  SHALL  BE  IN
STRICT  ACCORDANCE  WITH  DRAWINGS  AND/OR  AS
DIRECTED BY ARCHITECT/ENGINEER.

F. THE  CONTRACTOR  PERFORMING  THE  DEMOLITION
WORK  SHALL  REMOVE  NO  MORE  THAN  8"  OF
BUILDING  MATERIAL  AROUND  EACH  DEVICE  BEING
DEMOLISHED.

G. NOT  ALL  AREAS  MAY  HAVE  BEEN  AVAILABLE  FOR
SURVEY  DURING  DESIGN.  THE  CONTRACTOR  SHALL
THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE
OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS
IN  QUESTION  OR  THAT  COULD  NOT  BE  OBSERVED
SHALL  BE  OUTLINED  IN  THE  CONTRACTORS  BID.

ADDITIONAL  COMPENSATION  FOR  FAILURE  TO  FIELD
VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS  WILL  NOT  BE  APPROVED.  EXISTING  SYSTEMS
ARE  SHOWN  BASED  ON  VISUAL  INSPECTION  AND
AS-BUILT/DESIGNED  DOCUMENTS  AND  MAY  NOT
REFLECT ACTUAL CONDITIONS.

H. ALL  LOCATIONS  SHOWN  ON  THESE  DRAWINGS  ARE
APPROXIMATE. VERIFY EXACT LOCATIONS IN FIELD.

I. THE  DEVICES  AND  EQUIPMENT  INDICATED  BY
DEMOLITION  SYMBOLS  ON  THE  PLANS  ARE  NOT
NECESSARILY THE LIMITS OF THE WORK INVOLVED IN
THE  RENOVATION.  THE  CONTRACTOR  SHALL
CAREFULLY  EXAMINE  THE  COMPLETE  SET  OF
ENGINEER  &  ARCHITECTURAL  PLANS  FOR  ALL
TRADES  AND  PERFORM  A  DETAILED  FIELD  SURVEY
DURING THE BIDDING PERIOD TO ENSURE THAT THE
ENTIRE  SCOPE  OF  WORK  INVOLVED  IS  INCLUDED  IN
THE BID PRICE.

LEGENDS
X
X
X
X
XX
DEMOLISH EXISTING DIFFUSER/GRILLE
AND DUCTWORK
SCOPE OF WORK LIMIT
DEMO KEYNOTE:

1. CONTRACTOR TO DEMOLISH THE HIGHLIGHTED EXISTING
DUCTWORK AND DIFFUSER OR GRILLE.

2. REMOVE  EXISTING  DIFFUSER  AND  ASSOCIATED
DUCTWORK.  CAP  AND  SEAL  THE  REMAINING  DUCT
BRANCH FOR FUTURE CONNECTION.
2 1
1 2
2 1
1 1
1 2
1 1
1 1
1 1

X X X X
2 2
2 2
1 1
1 1
1 1
1 2
2 2
2 2
1 2
M1.1
ADMINISTRATION BUILDING: MECHANICAL 2ND
FLOOR DEMO PLAN
NORTH
SCALE:

ADMINISTRATION BUILDING: MECHANICAL 2ND FLOOR DEMO PLAN 1 3/16" = 1'-0" UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1402 of 1646 ends

(N)STORAGE Microwave DW
Oven
(E)PRINTER
(N)STORAGE LOUNGE DRIVERS' VESRIBULE DISPATCH

CORRIDOR CORRIDOR CORRIDORTRAINING ROOM TRAINING ROOM KITCHENETTE (N)8"SA (N)8"SA
(N)8"SA (N)8"SA
12"SA
(E)24"X16"SA
(E)16"X8"SA
(N)8"SA
(N)10"SA
8"SA
(N)14"X10"SA
(N)8"SA (N)8"SA
(N)10"SA
(N)8"SA
(N)8"SA
(E)20"X10"SA
(E)16"X10"SA
(E)34"X10"SA
(E)16"X12"SA
(E)20"X10"SA
(E)18"X8"SA
(N)10"ØSA
(N)8"ØSA
(N)8"ØSA
(N)8"ØSA
(N)8"ØSA
(N)8"ØSA
(N)8"ØSA
(N)8"SA (N)10"SA
(N)8"ØSA
(E)20"X16"SA
(N)8"ØSA
(E)24"X12"
(E)48"X14"SA
(E)36"X18"RA

1. ALL  DUCTWORK  SHALL  CONFIRM  TO  SMACNA
STANDARDS.ALL  DUCTWORK  SIZES  ARE  NET  INSIDE
DIMENSIONS.

2. MECHANICAL CONTRACTOR TO COORDINATE DUCT LAYOUT
AND DIMENSIONS WITH FIELD VERIFIED.

3. ALL  WORK  SHALL  BE  PERFORMED  IN  ACCORDANCE  WITH THE LATEST EDITION OF CALIFORNIA MECHANICAL CODE.

4. EXHAUST  DUCTS  SHALL  BE  EQUIPPED  WITH  BACK-DRAFT DAMPERS PER SECTION 504.1.1 CMC.

5. SCREENS/LOUVERS  SHALL  NOT  BE  INSTALLED  AT  DRYER VENT TERMINATIONS PER SECTION 504.4 CMC.

6. EXISTING DUCTWORK, PLENUM SHOWN AS PLACEHOLDER,
CONTRACTOR  NEED  TO  VERIFY  ON  SITE  FOR  ACTUAL
INSTALLATION, SIZE AND LAYOUT.

MECHANICAL GENERAL NOTES
(E)ZD-8
(E)ZD-7 T
(E)ZD-6 T
(E)ZD-5 T
T
T
(R)ZD-2 T
(E)ZD-4
T
(E)ZD-1
T
(E)ZD-3
(R)ZD-10 T
T
(E)ZD-11 T
(E)ZD-9
(N)8"ØSA
SCOPE OF WORK
S-200-D
16"X16" S-200-D
S-200-D 16"X16"
16"X16"
S-200-D
16"X16"
S-200-D
16"X16"
S-60-B
8"X8"
S-215-D
16"X16" S-220-D
16"X16"
S-220-D
16"X16"
S-215-D
16"X16" S-215-D
16"X16"
S-215-D
16"X16"
S-170-D
16"X16"
S-170-D
16"X16"
S-175-D
16"X16"
S-175-D
16"X16"
R-185-H
24"X24"
R-715-H
24"X24"
S-200-A
10"X10"
S-375-A
24"X24"
S-375-A
24"X24"
S-375-A
24"X24"
S-390-A
24"X24"
R-590-H
24"X24"
S-395-A
24"X24"
S-395-A
24"X24"
S-150-A
24"X24" S-150-A
24"X24"
R-590-H
24"X24"
R-715-H
24"X24"
10D
9F
11C
8B
(E)ZD
7B 6D
5E 4C
3C
2E
1D
1180
CFM
1425
CFM
635
CFM
1005
CFM
330
CFM
430
CFM
1470
CFM
625
CFM
2045
CFM
1060
CFM
690
CFM
(E)12"x12"
(E)12"x10"
(E)18"x14"
(E)20"x16"(E)16"x12"
R-645-G
18"X18"
R-655-G
18"X18"
R-690-G
18"X18"
(E)ZD
(E)ZD
(E)ZD (E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
R-500-G
18"X18"
R-500-G
18"X18"
12C
750
CFM
(E)ZD
1 (E)VF
(E)20"X8"
(E)9"Ø
(E)10"Ø
KEYNOTE:

1. EXISTING  THERMOSTAT  TO  REMAIN,  CONTRACTOR  TO
PROVIDE LOW  VOLTAGE POWER TO THERMOSTAT.

2. CONTRACTOR TO RELOCATE EXISTING THERMOSTAT AND
PROVIDE LOW VOLTAGE POWER.
1 1
1 2
1 1 1
2 1
1 1
M1.2
ADMINISTRATION BUILDING: MECHANICAL 1ST
FLOOR PROPOSED PLAN
NORTH
SCALE:

ADMINISTRATION BUILDING: MECHANICAL 1ST FLOOR PLAN 1 3/16" = 1'-0" UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1403 of 1646 ends

TV TV TV DECK ROOF CORRIDOR KITCHENETTE LOUNGE CONFERENCE ROOM (E)8"ØSA
(E)10"X10"SA
(N)9"ØSA
(E)12"X12"
(E)16"X14"
(E)14"X12"
(N)8"ØSA (N)10"ØSA
8"ØSA
8"ØSA
10"ØSA
(E)36"x18"SA
(E)36"x18"RA
8"ØEA
8"ØEA
18"X18"UP
22"X10"DN
(E)6"ØSA
(E)VF
2 (N)16"X8"SA
48"X16"RA
40"X18"RA
8"ØSA
KEYNOTE:

1. BLANK  OFF  2  FEET  OF  SLOT  BETWEEN  SUPPLY  PLENUM AND ARCHITECTURAL RETURN SLOT.

2. ARCHITECTURAL   CONTINUOUS   SLOT   IN   CEILING   FOR RETURN AIR  TO  PLENUM.

3. EXISTING VENT FAN TO REMAIN.

4. EXISTING  THERMOSTAT  TO  REMAIN,  CONTRACTOR  TO
PROVIDE LOW  VOLTAGE POWER TO THERMOSTAT.

5. CONTRACTOR TO RELOCATE EXISTING THERMOSTAT AND
PROVIDE LOW VOLTAGE POWER.

6. KITCHEN/LOUNGE  AREA  HAS  SUFFICIENT  SUPPLY  CFM,
COOLING  LOAD  ATTACHED  IN  MECHANICAL  SCHEDULE
SHEET NO. 6.
(E)7"Ø
(E)6"Ø
(N)8"Ø
(N)6"Ø
(N)8"Ø
(E)7"Ø
(N)8"Ø
(N)10"Ø
(N)10"ØEA
10"ØEA
(E)10"X8"SA

1. ALL  DUCTWORK  SHALL  CONFIRM  TO  SMACNA
STANDARDS.ALL  DUCTWORK  SIZES  ARE  NET  INSIDE
DIMENSIONS.

2. MECHANICAL CONTRACTOR TO COORDINATE DUCT LAYOUT
AND DIMENSIONS WITH FIELD VERIFIED.

3. ALL  WORK  SHALL  BE  PERFORMED  IN  ACCORDANCE  WITH THE LATEST EDITION OF CALIFORNIA MECHANICAL CODE.

4. EXHAUST  DUCTS  SHALL  BE  EQUIPPED  WITH  BACK-DRAFT DAMPERS PER SECTION 504.1.1 CMC.

5. SCREENS/LOUVERS  SHALL  NOT  BE  INSTALLED  AT  DRYER VENT TERMINATIONS PER SECTION 504.4 CMC.

6. EXISTING DUCTWORK, PLENUM SHOWN AS PLACEHOLDER,
CONTRACTOR  NEED  TO  VERIFY  ON  SITE  FOR  ACTUAL
INSTALLATION, SIZE AND LAYOUT.

MECHANICAL GENERAL NOTES
T
(E)ZD-17
T
(R)ZD-16
T
(E)ZD-15
T
(E)ZD-18
T
(E)ZD-14
T (E)ZD-19
T
(E)ZD-21
T
(E)ZD-20
SCOPE OF WORK
R-770-G
24"X24"
R-270-G
18"X18" S-150-B
8"X8"
S-270-C
10"X10"
R-135-F
10"X10"
R-270-F
10"X10"
S-190-D
16"X16"
S-190-D
16"X16"
R-600-G
18"X18"
S-500-D
16"X16"
R-120-E
8"X8"
R-50-E
8"X8"
R-50-E
8"X8"
R-120-E
8"X8"
17C
16C
770
CFM
930
CFM
19B
21E
1850
CFM
R-235-F
10"X10"
S-360-C
10"X10"
20B
380
CFM
24E
1620
CFM
13E
1540
CFM
14C
720
CFM
18C
720
CFM
15C
720
CFM
(E)20"x14"
(E)12"x12"
(E)14"x12"
(E)12"X12"
36"X18"RA
36"X18"SA
8"Ø
8"Ø 8"Ø
8"Ø 12"Ø 10"Ø
12"Ø
8"Ø
8"Ø
8"Ø
8"Ø
12"x12"
10"Ø
12"x12"
LD-1
230 LD-1
235 LD-1
235
LD-1
235
LD-1
195
LD-1
190
LD-1
195
LD-1
190
LDR-1
LDR-1
LDR-1
LDR-1
R-70-F
10"X10"
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)ZD
(E)18"X12"SA (E)18"X12"SA
(E)12"x6"
S-150-B
8"X8"
(N)8"ØSA
S-165-D
16"X16" S-195-D
16"X16"
S-220-D
16"X16"
10"ØSA
435
CFM
2 1
1 1
4 2
5 4
2 4
4 4
6 S-200-D
16"X16"
4 4
M1.3
ADMINISTRATION BUILDING: MECHANICAL 2ND
FLOOR PROPOSED PLAN
NORTH
SCALE:

ADMINISTRATION BUILDING: MECHANICAL 2ND FLOOR PLAN 1 3/16" = 1'-0" UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1404 of 1646 ends

LOCKER
SHOWER
LOCKER
SHOWER BREAK ROOM
MEN'S LOCKERS
MEN'S TOILET
WOMEN'S TOILET LOCKER
SHOWER
LOCKER
SHOWER
MEN'S LOCKERS
MEN'S TOILET
WOMEN'S TOILET
DEMO GENERAL NOTE:

A. ALL DEMOLITION OF THE HVAC SYSTEM AS CALLED FOR ON THE DEMOLITION DRAWINGS SHALL BE UNDER THE MECHANICAL (HVAC) CONTRACTORS WORK.

B. BEFORE  STARTING  ANY  DEMOLITION  ON  HVAC  EQUIPMENT  WHICH  HAS  AN ELECTRICAL CONNECTION, THE MECHANICAL CONTRACTOR SHALL MEET WITH THE  ELECTRICAL  CONTRACTOR  TO  IDENTIFY  ALL  SUCH  EQUIPMENT.  THE ELECTRICAL  CONTRACTOR  WILL  DISCONNECT  THE  POWER  TO  EACH  UNIT, REMOVE  CONDUIT,  WIRING,  DISCONNECT  SWITCHES  AND  STARTERS  UNDER HIS  CONTRACT.  MECHANICAL  CONTRACTOR  WILL  REMOVE  ALL  EQUIPMENT, ELECTRIC  TEMPERATURE  CONTROL  WIRING  AND  CONDUIT  UNDER  THIS CONTRACT.

C. CAP AND SEAL AT POINT OF DISCONNECT TO MAINTAIN THE AIRFLOW IN THE SPACES OUTSIDE OF THE PROJECT SCOPE.

D. ALL EQUIPMENT,  MATERIAL, ETC. THAT  IS BEING DEMOLISHED WILL BECOME THE PROPERTY OF THE MECHANICAL CONTRACTOR. ALL SUCH ITEMS WILL BE REMOVED FROM THE BUILDING SITE BY THE MECHANICAL CONTRACTOR. NO ITEM WHICH IS BEING REMOVED UNDER THE DEMOLITION CONTRACT MAY BE REUSED UNDER THE NEW WORK CONTRACT.

E. SEQUENCE  OF  ALL  DEMOLITION  WORK  SHALL  BE  IN  STRICT  ACCORDANCE WITH  THE  SPECIFICATIONS,  DRAWINGS  AND/OR  AS  DIRECTED  BY ARCHITECT/ENGINEER.

F. THE CONTRACTOR PERFORMING THE DEMOLITION WORK SHALL REMOVE NO MORE  THAN  8"  OF  BUILDING  MATERIAL  AROUND  EACH  DEVICE  BEING DEMOLISHED.

G. NOT  ALL  AREAS  MAY  HAVE  BEEN  AVAILABLE  FOR  SURVEY  DURING  DESIGN.

THE  CONTRACTOR  SHALL  THOROUGHLY  REVIEW  ALL  AREAS  WITHIN  THE SCOPE OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS IN QUESTION OR THAT COULD NOT BE OBSERVED SHALL BE OUTLINED IN THE CONTRACTORS BID.  ADDITIONAL  COMPENSATION  FOR  FAILURE  TO  FIELD  VERIFY  EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS WILL NOT BE APPROVED. EXISTING SYSTEMS  ARE  SHOWN  BASED  ON  VISUAL  INSPECTION  AND AS-BUILT/DESIGNED  DOCUMENTS  AND  MAY  NOT  REFLECT  ACTUAL CONDITIONS.

H. ALL  LOCATIONS  SHOWN  ON  THESE  DRAWINGS  ARE  APPROXIMATE.  VERIFY EXACT LOCATIONS IN FIELD.

I. THE DEVICES AND EQUIPMENT INDICATED BY DEMOLITION SYMBOLS ON THE PLANS  ARE  NOT  NECESSARILY  THE  LIMITS  OF  THE  WORK  INVOLVED  IN  THE RENOVATION. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE COMPLETE SET OF ENGINEER & ARCHITECTURAL PLANS FOR ALL TRADES AND PERFORM A  DETAILED  FIELD  SURVEY  DURING  THE  BIDDING  PERIOD  TO  ENSURE  THAT THE ENTIRE SCOPE OF WORK INVOLVED IS INCLUDED IN THE BID PRICE.

1. ALL DUCTWORK SHALL CONFIRM TO SMACNA STANDARDS.ALL DUCTWORK SIZES ARE NET INSIDE DIMENSIONS.

2. MECHANICAL  CONTRACTOR  TO  COORDINATE  DUCT  LAYOUT  AND  DIMENSIONS WITH FIELD VERIFIED.

3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF CALIFORNIA MECHANICAL CODE.

4. EXHAUST DUCTS SHALL BE EQUIPPED WITH BACK-DRAFT DAMPERS PER SECTION 504.1.1 CMC.

5. SCREENS/LOUVERS  SHALL  NOT  BE  INSTALLED  AT  DRYER  VENT  TERMINATIONS PER SECTION 504.4 CMC.

6. EXISTING  DUCTWORK,  PLENUM  SHOWN  AS  PLACEHOLDER,  CONTRACTOR  NEED TO VERIFY ON SITE FOR ACTUAL INSTALLATION, SIZE AND LAYOUT.

MECHANICAL GENERAL NOTES
KEYNOTE:

1. CONTRACTOR  TO  DEMOLISH  THE  HIGHLIGHTED  EXISTING  DUCTWORK  AND DIFFUSER OR GRILLE.

SCOPE OF WORK
SCOPE OF WORK SCOPE OF WORK
1 1
1 1
1 1
M1.4
MAINTENANCE BUILDING 1ST & 2ND FLOOR
DEMOLITION PLAN
NORTH
SCALE:

MAINTENANCE BUILDING: MECHANICAL DEMO 2ND FLOOR PLAN 2 1/4" = 1'-0" NORTH
SCALE:

MAINTENANCE BUILDING: MECHANICAL DEMO 1ST FLOOR PLAN 1 1/4" = 1'-0" UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1405 of 1646 ends

STAIRS
BREAK ROOM

1. ALL DUCTWORK SHALL CONFIRM TO SMACNA STANDARDS.ALL DUCTWORK SIZES ARE NET INSIDE DIMENSIONS.

2. MECHANICAL  CONTRACTOR  TO  COORDINATE  DUCT  LAYOUT  AND  DIMENSIONS WITH FIELD VERIFIED.

3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF CALIFORNIA MECHANICAL CODE.

4. EXHAUST DUCTS SHALL BE EQUIPPED WITH BACK-DRAFT DAMPERS PER SECTION 504.1.1 CMC.

5. SCREENS/LOUVERS  SHALL  NOT  BE  INSTALLED  AT  DRYER  VENT  TERMINATIONS PER SECTION 504.4 CMC.

6. EXISTING  DUCTWORK,  PLENUM  SHOWN  AS  PLACEHOLDER,  CONTRACTOR  NEED TO VERIFY ON SITE FOR ACTUAL INSTALLATION, SIZE AND LAYOUT.

MECHANICAL GENERAL NOTES
SCOPE OF WORK SCOPE OF WORK
SCOPE OF WORK
KEYNOTE:

1. CONTRACTOR  SHALL  PROVIDE  SUPPLY  DIFFUSERS  AS  SHOWN  ON  THE  PLAN AND DISTRIBUTE THE CFM AND CONNECT TO NEAREST EXISTING SUPPLY DUCT WORK.

2. CONTRACTOR SHALL PROVIDE EXHAUST GRILLE  AS SHOWN ON THE PLAN AND TAKE  CFM  AS  PER  MENTION  AND  CONNECT  TO  NEAREST  EXISTING EXHAUST DOCTWORK.

S-140-A
24"X24"
S-140-A
24"X24"
S-140-A
24"X24"
S-140-A
24"X24"
S-170-A
24"X24"
S-120-A
24"X24"
S-120-A
24"X24"
S-120-A
24"X24"
S-120-A
24"X24"
S-120-A
24"X24"
S-120-A
24"X24"
1 1
1 1
1 1
1 1
1 1
1 R-50-E
8"X8"
R-50-E
8"X8"
R-50-E
8"X8"
R-50-E
8"X8"
R-50-E
8"X8"
R-50-E
8"X8"
R-50-E
8"X8"
R-30-E
8"X8"
R-30-E
8"X8"
R-30-E
8"X8"
R-30-E
8"X8"
R-30-E
8"X8"
R-560-G
24"X24"
R-720-G
24"X24"
2 2
2 2
2 2
R-170-G
24"X24"
R-50-E
8"X8"
M1.5
MAINTENANCE BUILDING 1ST & 2ND FLOOR
PROPOSED PLAN
NORTH
SCALE:

MAINTENANCE BUILDING: MECHANICAL 1ST FLOOR PLAN 1 1/4" = 1'-0" NORTH
SCALE:

MAINTENANCE BUILDING: MECHANICAL 2ND FLOOR PLAN 2 1/4" = 1'-0" UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1406 of 1646 ends

DEMO GENERAL NOTE:

A. ALL  DEMOLITION  OF  THE  HVAC  SYSTEM  AS  CALLED  FOR  ON  THE  DEMOLITION  DRAWINGS SHALL BE UNDER THE MECHANICAL (HVAC) CONTRACTORS WORK.

B. BEFORE  STARTING  ANY  DEMOLITION  ON  HVAC  EQUIPMENT  WHICH  HAS  AN  ELECTRICAL CONNECTION,  THE  MECHANICAL  CONTRACTOR  SHALL  MEET  WITH  THE  ELECTRICAL CONTRACTOR  TO  IDENTIFY  ALL  SUCH  EQUIPMENT.  THE  ELECTRICAL  CONTRACTOR  WILL DISCONNECT  THE  POWER  TO  EACH  UNIT,  REMOVE  CONDUIT,  WIRING,  DISCONNECT SWITCHES  AND  STARTERS  UNDER  HIS  CONTRACT.  MECHANICAL  CONTRACTOR  WILL REMOVE ALL EQUIPMENT, ELECTRIC TEMPERATURE CONTROL WIRING AND CONDUIT UNDER THIS CONTRACT.

C. CAP  AND  SEAL  AT  POINT  OF  DISCONNECT  TO  MAINTAIN  THE  AIRFLOW  IN  THE  SPACES OUTSIDE OF THE PROJECT SCOPE.

D. ALL EQUIPMENT, MATERIAL, ETC. THAT IS BEING DEMOLISHED WILL BECOME THE PROPERTY OF  THE  MECHANICAL  CONTRACTOR.  ALL  SUCH  ITEMS  WILL  BE  REMOVED  FROM  THE BUILDING  SITE  BY  THE  MECHANICAL  CONTRACTOR.  NO  ITEM  WHICH  IS  BEING  REMOVED UNDER THE DEMOLITION CONTRACT MAY BE REUSED UNDER THE NEW WORK CONTRACT.

E. SEQUENCE  OF  ALL  DEMOLITION  WORK  SHALL  BE  IN  STRICT  ACCORDANCE  WITH  THE SPECIFICATIONS, DRAWINGS AND/OR AS DIRECTED BY ARCHITECT/ENGINEER.

F. THE CONTRACTOR PERFORMING THE DEMOLITION WORK SHALL REMOVE NO MORE THAN 8" OF BUILDING MATERIAL AROUND EACH DEVICE BEING DEMOLISHED.

G. NOT  ALL  AREAS  MAY  HAVE  BEEN  AVAILABLE  FOR  SURVEY  DURING  DESIGN.  THE CONTRACTOR SHALL THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE OF WORK PRIOR TO  SUBMITTING  HIS  BID.  ANY  AREAS  IN  QUESTION  OR  THAT  COULD  NOT  BE  OBSERVED SHALL BE OUTLINED IN THE CONTRACTORS BID. ADDITIONAL COMPENSATION FOR FAILURE TO  FIELD  VERIFY  EXISTING  CONDITIONS  PRIOR  TO  SUBMITTING  BIDS  WILL  NOT  BE APPROVED.  EXISTING  SYSTEMS  ARE  SHOWN  BASED  ON  VISUAL  INSPECTION  AND AS-BUILT/DESIGNED DOCUMENTS AND MAY NOT REFLECT ACTUAL CONDITIONS.

H. ALL  LOCATIONS  SHOWN  ON  THESE  DRAWINGS  ARE  APPROXIMATE.  VERIFY  EXACT LOCATIONS IN FIELD.

I. THE  DEVICES  AND  EQUIPMENT  INDICATED  BY  DEMOLITION  SYMBOLS  ON  THE  PLANS  ARE NOT  NECESSARILY  THE  LIMITS  OF  THE  WORK  INVOLVED  IN  THE  RENOVATION.  THE CONTRACTOR  SHALL  CAREFULLY  EXAMINE  THE  COMPLETE  SET  OF  ENGINEER  & ARCHITECTURAL PLANS FOR ALL TRADES AND PERFORM A DETAILED FIELD SURVEY DURING THE  BIDDING  PERIOD  TO  ENSURE  THAT  THE  ENTIRE  SCOPE  OF  WORK  INVOLVED  IS INCLUDED IN THE BID PRICE.

KEYNOTE:

1. CONTRACTOR TO DEMOLISH SPACE'S EXISTING  DIFFUSER OR GRILLE AND CAPED AND SEAL THE EXISTING DUCT.
1 1
1 1
Lobby 1 10 21 OFFICE
Copy RM Electrical  RM
EEOC
8 9 Admin Office
22 Kitchenette
13 16
Boiler RM
19 Sink
STORE RM Phone and Electrical
15      Hall C
Lunch Room
4 5
3 Paint Booth
14 20
Closet EEOC
EEOC      12    Hall Area B
2 Manager of St. Div Administrative Staff Area
Office Streets Supervisor
Conference Room
General Staff Office
Body Shop 1st Floor Storage Room 6   Hall Area A
Conference RM
Sink Unisex Unisex Restroom 1 Restroom 2
711 Women's Restroom 18 Men's Restroom 17 M1.6
311 BUILDING - DEMOLITION RESTROOM
FLOOR PLAN
SCALE:

DEMOLITION PLAN - WOMEN'S RESTROOM 4 3/8" = 1'-0"
SCALE:

DEMOLITION PLAN - UNISEX RESTROOM 2 3 3/8" = 1'-0"
SCALE:

DEMOLITION PLAN - UNISEX RESTROOM 1 1 3/8" = 1'-0" SCALE:

DEMOLITION PLAN - MEN'S RESTROOM 2 3/8" = 1'-0"
KEY PLAN
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1407 of 1646 ends

C.H.= 07'-11"
C.H.= 09'-1"
C.H.= 8'-11"
C.H.= 8'-00"
C.H.= 8'-00"

1. ALL  DUCTWORK  SHALL  CONFIRM  TO  SMACNA  STANDARDS.ALL  DUCTWORK  SIZES  ARE  NET INSIDE DIMENSIONS.

2. MECHANICAL  CONTRACTOR  TO  COORDINATE  DUCT  LAYOUT  AND  DIMENSIONS  WITH  FIELD VERIFIED.

3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF CALIFORNIA MECHANICAL CODE.

4. EXHAUST DUCTS SHALL BE EQUIPPED WITH BACK-DRAFT DAMPERS PER SECTION 504.1.1 CMC.

5. SCREENS/LOUVERS SHALL NOT BE INSTALLED AT DRYER VENT TERMINATIONS PER SECTION 504.4 CMC.

6. EXISTING DUCTWORK, PLENUM SHOWN AS PLACEHOLDER, CONTRACTOR NEED TO VERIFY ON SITE FOR ACTUAL INSTALLATION, SIZE AND LAYOUT.

MECHANICAL GENERAL NOTES
KEYNOTE:

1. CONTRACTOR SHALL PROVIDE EXHAUST GRILLE  AS SHOWN ON THE PLAN AND TAKE CFM AS PER MENTION AND CONNECT TO NEAREST EXISTING EXHAUST DOCTWORK.

2. CONTRACTOR  SHALL  PROVIDE  SUPPLY  DIFFUSERS  AS  SHOWN  ON  THE  PLAN  AND DISTRIBUTE THE CFM AND CONNECT TO NEAREST EXISTING SUPPLY DUCT WORK.

R-50-E
8"X8"
R-50-E
8"X8"
E-50-E
8"X8"
E-30-E
8"X8"
E-50-E
8"X8"
E-30-E
8"X8"
E-50-E
8"X8"
E-50-E
8"X8"
E-30-E
8"X8"
E-50-E
8"X8"
E-50-E
8"X8"
1 1
1 1
1 1
1 R-150-F
10"X10"
1 2
E-100-F
10"X10"
S-80-D
16"X16"
2 1
E-150-F
10"X10"
S-300-A
24"X24"
Lobby 1 10 21 OFFICE
Copy RM Electrical  RM
EEOC
8 9 Admin Office
22 Kitchenette
13 16
Boiler RM
19 Sink
STORE RM Phone and Electrical
15      Hall C
Lunch Room
4 5
3 Paint Booth
14 20
Closet EEOC
EEOC      12    Hall Area B
2 Manager of St. Div Administrative Staff Area
Office Streets Supervisor
Conference Room
General Staff Office
Body Shop 1st Floor Storage Room 6   Hall Area A
Conference RM
Sink Unisex Unisex Restroom 1 Restroom 2
711 Women's Restroom 18 Men's Restroom 17 M1.7
311 BUILDING - PROPOSED RESTROOM RCP
PLAN
SCALE:

PROPOSED PLAN - WOMEN'S RESTROOM 4 3/8" = 1'-0"
SCALE:

PROPOSED  PLAN - UNISEX RESTROOM 2 3 3/8" = 1'-0"
SCALE:

PROPOSED  PLAN - UNISEX RESTROOM 1 1 3/8" = 1'-0"
SCALE:

PROPOSED  PLAN - MEN'S RESTROOM 2 3/8" = 1'-0"
KEY PLAN
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1408 of 1646 ends

10'-00" C.H.= C.H.= 08'-00" RESTROOM

1. ALL  DUCTWORK  SHALL  CONFIRM  TO  SMACNA  STANDARDS.ALL  DUCTWORK  SIZES  ARE  NET INSIDE DIMENSIONS.

2. MECHANICAL  CONTRACTOR  TO  COORDINATE  DUCT  LAYOUT  AND  DIMENSIONS  WITH  FIELD VERIFIED.

3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF CALIFORNIA MECHANICAL CODE.

4. EXHAUST  DUCTS  SHALL  BE  EQUIPPED  WITH  BACK-DRAFT  DAMPERS  PER  SECTION  504.1.1 CMC.

5. SCREENS/LOUVERS SHALL NOT BE INSTALLED AT DRYER VENT TERMINATIONS PER SECTION 504.4 CMC.

6. EXISTING DUCTWORK, PLENUM SHOWN AS PLACEHOLDER, CONTRACTOR NEED TO VERIFY ON SITE FOR ACTUAL INSTALLATION, SIZE AND LAYOUT.

MECHANICAL GENERAL NOTES:

DEMO GENERAL NOTE:

A. ALL  DEMOLITION  OF THE  HVAC SYSTEM AS  CALLED FOR ON  THE DEMOLITION  DRAWINGS SHALL BE UNDER THE MECHANICAL (HVAC) CONTRACTORS WORK.

B. BEFORE  STARTING  ANY  DEMOLITION  ON  HVAC  EQUIPMENT  WHICH  HAS  AN  ELECTRICAL CONNECTION,  THE  MECHANICAL  CONTRACTOR  SHALL  MEET  WITH  THE  ELECTRICAL CONTRACTOR  TO  IDENTIFY  ALL  SUCH  EQUIPMENT.  THE  ELECTRICAL  CONTRACTOR  WILL DISCONNECT  THE  POWER  TO  EACH  UNIT,  REMOVE  CONDUIT,  WIRING,  DISCONNECT SWITCHES  AND  STARTERS  UNDER  HIS  CONTRACT.  MECHANICAL  CONTRACTOR  WILL REMOVE  ALL  EQUIPMENT,  ELECTRIC  TEMPERATURE  CONTROL  WIRING  AND  CONDUIT UNDER THIS CONTRACT.

C. CAP  AND  SEAL  AT  POINT  OF  DISCONNECT  TO  MAINTAIN  THE  AIRFLOW  IN  THE  SPACES OUTSIDE OF THE PROJECT SCOPE.

D. ALL  EQUIPMENT,  MATERIAL,  ETC.  THAT  IS  BEING  DEMOLISHED  WILL  BECOME  THE PROPERTY OF THE MECHANICAL CONTRACTOR. ALL SUCH ITEMS WILL BE REMOVED FROM THE BUILDING SITE BY THE MECHANICAL CONTRACTOR. NO ITEM WHICH IS BEING REMOVED UNDER THE DEMOLITION CONTRACT MAY BE REUSED UNDER THE NEW WORK CONTRACT.

E. SEQUENCE  OF  ALL  DEMOLITION  WORK  SHALL  BE  IN  STRICT  ACCORDANCE  WITH  THE SPECIFICATIONS, DRAWINGS AND/OR AS DIRECTED BY ARCHITECT/ENGINEER.

F. THE CONTRACTOR PERFORMING THE DEMOLITION WORK SHALL REMOVE NO MORE THAN 8" OF BUILDING MATERIAL AROUND EACH DEVICE BEING DEMOLISHED.

G. NOT  ALL  AREAS  MAY  HAVE  BEEN  AVAILABLE  FOR  SURVEY  DURING  DESIGN.  THE CONTRACTOR  SHALL  THOROUGHLY  REVIEW  ALL  AREAS  WITHIN  THE  SCOPE  OF  WORK PRIOR  TO  SUBMITTING  HIS  BID.  ANY  AREAS  IN  QUESTION  OR  THAT  COULD  NOT  BE OBSERVED  SHALL  BE  OUTLINED  IN  THE  CONTRACTORS  BID.  ADDITIONAL  COMPENSATION FOR FAILURE TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS WILL NOT BE  APPROVED.  EXISTING  SYSTEMS  ARE  SHOWN  BASED  ON  VISUAL  INSPECTION  AND AS-BUILT/DESIGNED DOCUMENTS AND MAY NOT REFLECT ACTUAL CONDITIONS.

H. ALL  LOCATIONS  SHOWN  ON  THESE  DRAWINGS  ARE  APPROXIMATE.  VERIFY  EXACT LOCATIONS IN FIELD.

I. THE  DEVICES  AND  EQUIPMENT  INDICATED  BY  DEMOLITION  SYMBOLS  ON  THE  PLANS  ARE NOT  NECESSARILY  THE  LIMITS  OF  THE  WORK  INVOLVED  IN  THE  RENOVATION.  THE CONTRACTOR  SHALL  CAREFULLY  EXAMINE  THE  COMPLETE  SET  OF  ENGINEER  & ARCHITECTURAL  PLANS  FOR  ALL  TRADES  AND  PERFORM  A  DETAILED  FIELD  SURVEY DURING THE BIDDING PERIOD TO ENSURE THAT THE ENTIRE SCOPE OF WORK INVOLVED IS INCLUDED IN THE BID PRICE.

KEYNOTE:

1. CONTRACTOR TO DEMOLISH SPACE'S EXISTING  DIFFUSER OR GRILLE.

2. CONTRACTOR SHALL PROVIDE EXHAUST GRILLE   AS SHOWN ON THE PLAN AND TAKE CFM AS PER MENTION AND CONNECT TO NEAREST EXISTING EXHAUST DOCTWORK. 1 1
R-50-E
8"X8"
2 R-50-E
8"X8"
E-50-E
8"X8"
E-50-E
8"X8"
GYM RESTROOM FUEL ISLAND
2     EXERCISE ROOM RESTROOM VESTIBULE

RESTROOM
M1.8
GYM RESTROOM AND FUEL ISLAND BUILDING
MECHANICAL DEMOLITION & PROPOSED PLAN
SCALE:

PROPOSED PLAN - FUEL ISLAND RESTROOM 3 3/8" = 1'-0"
SCALE:

DEMOLITION PLAN - FUEL ISLAND RESTROOM 1 3/8" = 1'-0"
SCALE:

PROPOSED PLAN - GYM RESTROOM 4 3/8" = 1'-0"
SCALE:

DEMOLITION PLAN - GYM RESTROOM 2 3/8" = 1'-0"
KEY PLAN
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1409 of 1646 ends

ROUND DUCT DAMPER DETAIL 1
TYPICAL BRANCH CONNECTION DETAILS
L=1/4W, 4" MIN.

O
L
W
TWO WAY TAP
SUPPLY (TWO WAY FLOW)
MAIN BRANCH FLOW
ONE WAY TAP
MAIN BRANCH FLOW
SUPPLY
V.D.

V.D.

SIDE OF MAIN OR
TRUNK DUCT
CLOSE OPENING
AT CORNERS
45° ENTRY, 0=45° SEAL
CONNECTION WITH A
MASTIC
SEALER
SUB BRANCH
AIR FLOW
AIR FLOW
SUB BRANCH
2 HANGER SUPPORT DETAIL
48" MAX
GAUGE PER LOAD
1" MINIMUM STEELBAND
HANGER OR THERMACLIP
AND SADDLESTRAP HANGER
1" STEEL BAND
WIRE
STRAP
STRAP
1" MINIMUM
ROUND DUCT HANGER DETAILS
HANGER
STRAPS
3 SUPPLY REGISTER
(DO NOT LOCATE
OVER JOIST CHORDS)
SUPPLY REGISTER
(DO NOT LOCATE
OVER JOIST CHORDS)
DUCT
STEEL BAND
WIRE HANGER
SIZE BOLTS FOR LOAD
3/8" DIA. MIN
ROD
SCREWS
W/ 1 1/2" MIN WIDTH;
BOLT
GASKET
GALVANIZED STEEL
BLADE SHALL BE 16 GAGE
GASKET 3/8" ROD

REGULATOR
1" WIDE x 16 GAGE
GALVANIZED STRAP (2 REQ'D)
INDICATING HANDLE AND
D<14"

LOCKNUT
SCREWS (2 REQ'D)
3/8" SQ. ROD W/SET
LOCKING QUADRANT

1. REFER TO PLANS FOR DIFFUSER LENGTHS AND PLENUM INLET CONNECTION.

2. INTERNAL LINEAR TO BE FULLY ENCAPSULATED (E.G. NEOPRENE).

3. FOR TYPE OF CEILING  SEE ARCHITECTURAL DWGS.

4. FLEXIBLE DUCT MAXIMUM LENGTH SHALL BE 7 FEET.

5. MAXIMUM ALLOWABLE SAG SHALL NOT EXCEED 1/2" PER L. FT.

SUPPLY/RETURN/EXHAUST
AIR
NOTES:

SUPPORT PLENUM BOX
FROM ABOVE (TYP. 4)
SCREW (TYP. 4)
SLIP (TYP. 4)
MANUFACTURER'S PLENUM
BOX W/INTERNAL INSULATION

CEILING
REFER TO SCHEDULES
FOR NUMBER OF SLOTS
AND FRAME TYPE
DUCT STRAP
SUPPORT FLEXIBLE
DUCT FROM ABOVE
DRAW BAND
W/DUCT SEALANT
LINEAR SLOT DIFFUSER CONNECTION DETAIL 4 NOT TO SCALE
NOT TO SCALE NOT TO SCALE NOT TO SCALE
SUPPLY AIR
SUPPLY AIR
NOTES:

FLEXIBLE DUCT MAXIMUM LENGTH SHALL BE 7
FEET. MINIMUM LENGTH SHALL BE 4 FEET.

ACOUSTICAL TILE CEILING SHOWN
(GYPBOARD CEILING SIMILAR).

USE SIDE CONNECTION IN TIGHT SPACES ONLY.

WHERE FLEXIBLE DUCTS ARE SHOWN ON
DRAWINGS PROVIDE SIMILAR PLENUM
FOR DUCTED RETURN/EXHAUST AIR GRILLES.

MAXIMUM ALLOWABLE SAG SHALL NOT EXCEED
1/2" PER LINER FT.

DHEET METAL
DUCT
SUPPORT FLEXIBLE DUCT
FROM STRUCTURE ABOVE
(SIZE PER SMACNA)
LOAD RATED FASTENERS
METAL CLAMP
1" WIDE GALVANIZED
SHEET METAL
DUCT STRAP
INSULATED FLEXIBLE DUCT
EARTHQUAKE TAB
12 GAUGE SECURITY
WIRE (TYP. 3)
CEILING DIFFUSER

CEILING
METAL CLAMP AT
DIFFUSER NECK
R=1.5D
2 GAUGE STEEL
SAFETY WIRE (TYP. 3)
LINED PLENUM WITH
HEIGHT=FLEX. DUCT
DIA. +2" WIDTH=DIFFUSER
NECK +2"
METAL CLAMP
AT PLENUM BOX
METAL CLAMP

CEILING

INSULATED
FLEXIBLE DUCT
CEILING DIFFUSER
SUPPORT FLEXIBLE DUCT
FROM STRUCTURE ABOVE
(SIZE PER SMACNA)
1" INTERNAL LINING
1" WIDE

GALVANIZED
SHEET METAL
DUCT STRAP
FLEXIBLE DUCTS SHALL NOT BE USED FOR
ENVIRONMENTAL EXHAUST.

ALL BRACING AND ATTACHMENT TO THE
STRUCTURE SHALL COMPLY WITH ASCE 7
GUIDELINES AND CBL AMENDMENTS IN
ACCORDANCE WITH ISAT PUBLICATIONS WITH AN
OSHPD PRE-APPROVAL NO. OPA-0485.
1 2
3 4
5 6
7 4 6
2 1
5 D
4 3
1 2
4 6
CEILING SUPPLY AIR DIFFUSER CONNECTION DETAIL 5 NOT TO SCALE SHEET METAL NOSING OR
APPROVED SEALANT
AT EXPOSED EDGES
DUCT STRAP

CEILING
RETURN AIR GRILLE OR REGISTER. GRILLE OR REGISTER TO
BE SIZED FOR TRANSFER AIR FUNCTION. SEE DIFFUSER
SCHEDULE FOR SIZES.

INTERNAL ACOUSTICAL LINING.

IF CEILING SPACE IS LIMITED, SIZE HORIZONTAL DUCT
TO UTILIZE MAXIMUM AVAILABLE HEIGHT AND PROVIDE
WIDTH TO ASSURE NO MORE THAN 300 FPM DUCT VELOCITY.

SIZING CHART
CFM SIZE (IN.)
UP TO 400 12X12
401 TO 600 18X12
601 TO 800 24X12
801 TO 1000 30X12
1001 T0 1500 30X16
1501 TO 2000 34X20
OVER 2000 USE MULTIPLE TRANSFER
DUCTS
1 2
. 6
"M
IN
. 3'-0"
RETURN AIR BOOT DETAIL 6 NOT TO SCALE
M5.0
MECHANICAL DETAILS
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1410 of 1646 ends

M6.0
MECHANICAL SCHEDULES
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1411 of 1646 ends

GENERAL NOTES & ABBREVIATIONSXref .\x101229-TBLK-E.dwg
TC
LC
PC
OS
ATS
C
TS
R
AV
PB
J
J
J
J
#10
CS
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
E1.0

Page 1412 of 1646 ends

Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA

9. DEMOLITION

10. EXECUTION
SECTION 260533 - RACEWAYS AND BOXES

11. MATERIAL AND INSTALLATION
SECTION 260553 - ELECTRICAL IDENTIFICATION

1. SCOPE

6. GUARANTEE

5. AS BUILT

4. SERVICE CONTINUITY

3. COORDINATION

2. VERIFYING EXISTING CONDITIONS

7. SHOP DRAWINGS

THE DRAWINGS AND THESE SPECIFICATIONS DESCRIBE THE
SYSTEMS. FURNISH ALL MATERIALS AND DO ALL WORK
REQUIRED BY THE DRAWINGS AND SPECIFICATIONS. UNLESS

SPECIFICALLY NOTED TO THE CONTRARY, FURNISH AND INSTALL

ALL NEW MATERIAL AND EQUIPMENT AS REQUIRED TO PRODUCE
A COMPLETE OPERATING SYSTEM.

BEFORE SUBMITTING BID, BECOME THOROUGHLY FAMILIAR WITH
ACTUAL EXISTING CONDITIONS AT THE BUILDING. THE INTENT OF

THE WORK IS SHOWN ON THE DRAWINGS AND DESCRIBED
HEREINAFTER. BY THE ACT OF SUBMITTING A BID PROPOSAL

FOR WORK, THE CONTRACTOR SHALL BE DEEMED TO HAVE MADE

SUCH A STUDY AND EXAMINATION AND TO ACCEPT ALL
CONDITIONS PRESENT AT THE SITE. NO REQUEST FOR

ADDITIONAL PAYMENT SHALL BE CONSIDERED AS VALID, DUE TO FAILURE TO ALLOW FOR CONDITIONS WHICH MAY EXIST.

COORDINATE ALL WORK WITH OTHER TRADES. OBTAIN ALL

DRAWINGS THAT WILL REQUIRE COORDINATION AND PROVIDE

ALL ELECTRICAL CONNECTIONS REQUIRED WHETHER SHOWN ON
ELECTRICAL DRAWINGS OR NOT.

CONSIDERATION TO THE OWNER AND ENGINEER PRIOR TO THE
BID IN WRITING. ALL SUBSTITUTIONS MUST BE REVIEWED BY THE ENGINEER. SUCH REVIEW SHALL NOT RELIEVE THE

CONTRACTOR FROM COMPLYING WITH THE REQUIREMENTS OF
THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL

BE RESPONSIBLE AT HIS OWN EXPENSE FOR ANY CHANGES

RESULTING FROM HIS PROPOSED SUBSTITUTIONS WHICH

AFFECT OTHER PARTS OF HIS OWN WORK OR THE WORK OF
OTHER CONTRACTORS.

ALL WORK AND MATERIAL SHALL CONFORM TO THE LATEST

RULES OF THE GOVERNING ELECTRICAL CODE AND

INSTALLATION SHALL BE OF THE LATEST INDUSTRY STANDARDS
OF WORKMANSHIP.

ALL MATERIALS SHALL BE NEW AND LISTED BY UNDERWRITERS
LABORATORY (U.L.), OR ANOTHER ACCEPTABLE INDEPENDENT
TESTING LABORATORY.

LOCATIONS OF ELECTRICAL EQUIPMENT, J-BOXES, AND CONDUIT RUNS SHOWN ON THE DRAWINGS ARE APPROXIMATE. FIELD

VERIFY FOR EXACT LOCATION AND ROUTING OF EXISTING

EQUIPMENT AND COORDINATE ALL NEW WORK WITH THE OTHER
DISCIPLINES TO AVOID CONFLICTS.

THIS CONTRACTOR IS TO OBTAIN AND REFER TO H.V.A.C.,

PLUMBING AND OTHER DRAWINGS AND PROVIDE ALL CONTROL
WIRING, RELAYS, STARTERS, TIME SWITCHES, CONDUITS, ETC.

INDICATED THEREON AS BEING PROVIDED UNDER THE
ELECTRICAL WORK.

UNINTERRUPTED SERVICES, INCLUDING LIFE SAFETY SYSTEMS

WHERE APPLICABLE, SHALL BE MAINTAINED TO ALL PARTS OF
THE BUILDING OTHER THAN WORK AREAS. SCHEDULE

SHUTDOWNS WITH THE OWNER, TO MAKE ALTERATIONS AND/OR
ADDITIONS TO MAIN SWITCHGEAR, ASSEMBLIES, FEEDERS.

PROVIDE ANY TEMPORARY SERVICES AS MAY BE REQUIRED.

REQUESTS FOR SHUTDOWN SHALL BE MADE AT LEAST 72 HOURS

IN ADVANCE TO THE OWNER AT WHICH TIME THE OWNER SHALL
SCHEDULE THE EXACT TIME AND DATE. IDENTIFY AT BID TIME,

ALL WORK TO BE DONE ON PREMIUM TIME AND TOTAL OVERTIME
MANHOURS REQUIRED FOR COMPLETION.

EFFECTIVELY BOND ELECTRICAL CABINETS, ENCLOSURES, AND

CONDUIT RACEWAY TO CODE APPROVED GROUNDS AS PARTS OF
CONTINUOUS GROUNDING SYSTEM.

IDENTIFY FEEDERS WITH THE CORRESPONDING CIRCUIT

DESIGNATION AT THE OVERCURRENT DEVICE, LOAD END, AND IN PULLBOXES.

PROVIDE RECORD DRAWINGS TO THE OWNER WITH ALL

CHANGES NOTED THEREON AT THE COMPLETION OF THE
PROJECT. RECORD DRAWINGS SHALL BE SIGNED AND DATED BY
CONTRACTOR.

CONTRACTOR SHALL UNCONDITIONALLY GUARANTEE ALL LABOR

AND MATERIALS ON ALL WORK AGAINST DEFECTS IN

WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR,
EXCEPT FOR LIGHTING FIXTURE LAMPS.

IDENTIFY BRANCH CIRCUITS WITH CORRESPONDING CIRCUIT

DESIGNATION AT THE OVERCURRENT DEVICE, AT ALL SPLICES,
AND IN JUNCTION BOXES.

MARK CIRCUIT DESIGNATION ON ALL JUNCTION BOX COVERS.

CIRCUIT DESIGNATION MEANS PANEL DESIGNATION AND CIRCUIT NUMBER, I.E.,G650-1.

INSTALLATION OF 600 VOLT CONDUCTORS: CONDUCTORS SHALL
BE CONTINUOUS BETWEEN OUTLETS OR JUNCTION BOXES. MAKE

SPLICES IN OUTLET BOXES, PULLBOXES OR PANELBOARD
GUTTERS. DO NOT SPLICE PANELBOARD FEEDERS.

COORDINATE ALL DEMOLITION WITH THE NEW REQUIREMENTS
TO ASSURE THAT EXISTING EQUIPMENT, WIRING, ETC., THAT IS

REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM IS NOT
REMOVED.

NOTIFY THE OWNER IMMEDIATELY WHEREVER EXISTING

EQUIPMENT IS ENCOUNTERED WHICH MUST BE RELOCATED DUE

TO THE NEW CONSTRUCTION, WHEN NOT INDICATED IN THE
DRAWINGS.

ALL REMOVED MATERIALS AND EQUIPMENT WHICH ARE
SALVAGEABLE SHALL REMAIN THE PROPERTY OF THE OWNER.

DELIVER SUCH SALVAGED MATERIALS AND EQUIPMENT ON THE

PREMISES AS DIRECTED BY OWNER, AND NEATLY PILE OR STORE THEM AND PROTECT FROM DAMAGE. REMOVE FROM PREMISES

AND DISPOSE OF ALL MATERIALS CONSIDERED BY THE OWNER
TO BE SCRAP.

CAREFULLY PROTECT ALL WALLS, TRIM, FLOORS, EQUIPMENT,
UTILITY LINES AND MATERIALS. WHEN WORKING ON FINISHED

SURFACES, LIMIT DAMAGE TO THE CONFINED SPACE AND

RESTORE TO THE ORIGINAL CONDITION ALL SURFACES WHICH
ARE DAMAGED BECAUSE OF THE INSTALLATION OF THIS WORK.

EQUIPMENT, MATERIALS AND SUPPLIES REMOVED FOR
PROTECTION SHALL BE REPLACED IN ORIGINAL LOCATIONS. ANY

MATERIALS DAMAGED SHALL BE REPLACED WITH NEW
MATERIALS OF LIKE KIND AND QUALITY AT NO COST TO OWNER.

DO ALL CUTTING AND PATCHING OF FLOORS, WALLS, CEILINGS, ETC., TO MATCH EXISTING. SCHEDULE CUTTING AND PATCHING
OF FLOORS WITH THE OWNER. CORE DRILLING FOR CONCRETE
WILL BE THE ONLY METHOD PERMITTED.

ANY EXISTING CONDUITS, PIPING, ETC. DAMAGED DURING THE

PROCESS OF CONSTRUCTION SHALL BE INSTALLED AND/OR

RECONNECTED AS REQUIRED FOR A COMPLETE AND OPERABLE
SYSTEM. NO ADDITIONAL CHARGES WILL BE ALLOWED FOR ANY

EQUIPMENT WHICH IS DAMAGED BY THIS CONTRACTOR DUE TO

THE INSTALLATION OF THE WORK OR FOR PUTTING EXISTING
SYSTEMS BACK INTO A COMPLETE OPERATING CONDITION.

PAINT ALL NEW EXPOSED ELECTRICAL RACEWAYS, CABINETS,

ENCLOSURES AND FITTINGS TO MATCH ADJACENT SURFACES IN
FINISHED AREAS.

SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS,
CEILINGS, FLOORS, ETC., TO MAINTAIN THE FIRE RATING.

FURNISH AND INSTALL FIRE RATED ENCLOSURES FOR ALL

EQUIPMENT PENETRATING INTO FIRE RATED ENVELOPES,
SPACES, ETC.

ALL EQUIPMENT TO BEAR U.L. LABEL OR THAT OF ANOTHER
ACCEPTABLE TESTING LABORATORY. SHOP DRAWINGS MUST BE

STAMPED BY THE CONTRACTOR FOR CONFORMANCE PRIOR TO
SUBMITTING. SUBMITTALS SHALL INCLUDE THE PROJECT NAME
AND CONTRACTORS NAME. SUBMIT SIX SETS OF SHOP

DRAWINGS AND AWAIT ENGINEERING REVIEW COMMENTS PRIOR

TO PURCHASING ALL PANELBOARDS, LIGHTING FIXTURES AND

LENSES, POWER DISTRIBUTION UNITS, CONTRACTORS, AND
DISCONNECT SWITCHES.

SECTION 260010 - BASIC ELECTRICAL REQUIREMENTS
END OF SECTION 260533
END OF SECTION 260553
END OF SECTION 260519
SECTION 260526 - GROUNDING

ALL FEEDERS AND BRANCH CIRCUIT WIRING SHALL HAVE

INSULATED EQUIPMENT GROUNDING CONDUCTOR SIZED PER
CEC.

END OF SECTION 260526
SECTION 260519 - CONDUCTORS

DELIVER ALL CONDUCTORS TO THE JOB SITE IN ORIGINAL
UNBROKEN CARTON OR REEL, PROPERLY TAGGED WITH U.L.

LABEL SIZE, TYPE, MANUFACTURER'S TRADE NAME AND THE
DATE MANUFACTURED (MUST BE MANUFACTURED WITHIN 6
MONTHS).

PROVIDE COPPER CONDUCTORS. #12 AWG MINIMUM, UNLESS
SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. PROVIDE
SOLID CONDUCTORS, #10 AWG AND SMALLER UNLESS
OTHERWISE NOTED. PROVIDE STRANDED CONDUCTORS, #8 AWG
AND LARGER UNLESS OTHERWISE NOTED. AT EQUIPMENT
SUBJECT TO VIBRATION, USE STRANDED CONDUCTORS.

USE CONDUCTORS WITH THHN/THWN 600 VOLTS INSULATION.

8. CONTRACTOR BID

CONTRACTOR'S BID SHALL BE BASED ON ALL WORK SHOWN ON
THE PLANS AND AS SPECIFIED. ALL PREMIUM TIME COSTS
REQUIRED SHALL BE INCLUDED IN THE BID. IF CONTRACTOR

PROPOSES TO SUBSTITUTE FOR EQUIPMENT SPECIFIED, HE

SHALL SUBMIT HIS REQUEST FOR

12. MATERIAL AND INSTALLATION

FURNISH ALL LABOR AND TEST EQUIPMENT AND SYSTEMS
REQUIRED UNDER THIS DIVISION.

TEST CIRCUITS FOR GROUNDS OR SHORTS. REPAIR DEFECTIVE
WIRING AS REQUIRED.

TEST CIRCUIT CONNECTED TO EQUIPMENT AT PANEL BOARD FOR
PROPER OPERATION.

UPON COMPLETION OF WORK, MAKE FINAL INSPECTION,

OPERATE EQUIPMENT UNDER NORMAL CONDITIONS, TO
SATISFACTION OF ENGINEER.

UPON COMPLETION OF WORK, PROVIDE WRITTEN CERTIFICATION

THAT ALL SYSTEMS ARE FUNCTIONING PROPERLY WITHOUT
DEFECTS.

ELECTRICAL METALLIC TUBING:STEEL, HOT DIPPED OR ELECTROGALVANIZED, MANUFACTURER: ALLIED ,WESTERN, OR APPROVED EQUAL.

CONDUIT FITTINGS: EMT FITTINGS - STEEL TYPE ONLY (DIE CAST

TYPE NOT ACCEPTABLE) CONNECTORS WITH INSULATED
THROAT. STRAPS - MALLEABLE IRON, ONE HOLE, HOT DIPPED
GALVANIZED. T&B 1200 OR 4100 SERIES. SPACERS - T&B 400
SERIES.

METAL CONDUIT: FOR EXPOSED OUTDOOR AREA, USE RIGID
STEEL CONDUIT (GRC): ANSI C80.1, INTERMEDIATE METAL
CONDUIT (IMC): RIGID STEEL. FITTINGS: ANSI/NEMA FB 1; ALL STEEL FITTINGS. USE INSULATED STEEL BUSHINGS WITH LUG
WHERE GROUND CONNECTIONS ARE REQUIRED. USE PLASTIC
BUSHINGS FOR NON-BONDING APPLICATIONS. SET SCREW
FITTINGS ARE NOT PERMITTED. DIE CAST OR PRESSURE CAST
FITTINGS ARE NOT PERMITTED. CONDUIT BODIES: ANSI/NEMA FB 1; STEEL OR MALLEABLE IRON.

FLEXIBLE METAL CONDUIT: DESCRIPTION: INTERLOCKED STEEL
CONSTRUCTION. FITTINGS: ANSI/NEMA FB 1; ALL STEEL FITTINGS.

PROVIDE INSULATED THROAT CONNECTORS. PROVIDE
WATERTIGHT SEAL AT OUTDOOR TERMINATION.

OUTLET BOXES AND COVERS: IN GENERAL - GALVANIZED

ONE-PIECE TYPE, NUMBER OF GANGS AS REQUIRED, AND WITH
BOX COVER TO SUIT FINISH. MANUFACTURER: STEEL CITY,

RACO, BOWERS, APPLETON, CROUSE-HINDS, KILLARK,
PYLE-NATIONAL, OR APPROVED EQUAL. JUNCTION BOXES FOR
INTERIOR WORK: STANDARD OUTLET BOXES (4 INCHES SQUARE
MINIMUM) WHERE POSSIBLE. WHERE OTHER THAN STANDARD

OUTLET BOXES ARE REQUIRED, USE CODE GAUGE SHEET BOX
WITH SCREW COVER OF TYPE TO SUIT.

SECTION 262726 - SWITCHES AND RECEPTACLES
PROVIDE 20 AMP NEMA RATED SWITCHES AND RECEPTACLES OF
SPECIFICATION GRADE. ALL SWITCHES SHALL BE RATED FOR 125 VOLT AND RECEPTACLES SHALL BE NEMA 5-20R, UNLESS
OTHERWISE NOTED. DEVICE BODY SHALL BE WHITE PLASTIC,
EXCEPT THAT EMERGENCY RECEPTACLES SHALL BE RED.

SPECIAL RECEPTACLES SHALL MATCH THE EQUIPMENT AS
LISTED. ALL COVERPLATES SHALL BE CAMPUS STANDARD
STAINLESS STEEL. WIRING DEVICES SHALL BE WHITE
(CONNECTED TO NORMAL POWER) AND RED (CONNECTED TO
EMERGENCY POWER). MOUNT RECEPTACLES IN THE VERTICAL
POSITION WITH THE GROUND PIN UP UNLESS OTHERWISE NOTED.

WRITE THE CIRCUIT NUMBER ON THE FRONT SIDE OF THE DEVICE BODY WITH PERMANENT BLACK MARKER (SHARPIE). LOCATE SO
THAT COVER PLATE CONCEALS NUMBER. USE A FINE POINT
BLACK PERMANENT MARKING PEN. IDENTIFY BY NOTING
PANELBOARD AND CIRCUIT NUMBER; FOR EXAMPLE, “HA1-16”.

PROVIDE INSCRIBED COVERPLATES FOR ALL RECEPTACLES AND

SWITCHES WITH PANEL CIRCUIT NUMBER (FOR EXAMPLE
“HA1-16”).

1. 2.

3. END OF SECTION 262726

THE EXACT LOCATION OF ALL ELECTRICAL DROPS AND CONDUIT

DROPS SHALL BE ADJUSTED TO CLEAR LIGHTS, DIFFUSERS,
DUCTS, ETC. COORDINATE LOCATION WITH USER.

4. SECTION 262200 - LOW VOLTAGE TRANSFORMERS
DESCRIPTION: FACTORY-ASSEMBLED AND -TESTED, AIR-COOLED
UNITS FOR 60-HZ SERVICE.

CORES: GRAIN-ORIENTED, NON-AGING SILICON STEEL.

COILS: CONTINUOUS WINDINGS WITHOUT SPLICES EXCEPT FOR
TAPS.

INTERNAL COIL CONNECTIONS: BRAZED OR PRESSURE TYPE.

COIL MATERIAL: ALUMINUM.

COMPLY WITH NEMA ST 20, AND LIST AND LABEL AS COMPLYING WITH UL 1561.

CORES: ONE LEG PER PHASE.

ENCLOSURE: VENTILATED, NEMA 250, TYPE 2.

CORE AND COIL SHALL BE ENCAPSULATED WITHIN RESIN
COMPOUND, SEALING OUT MOISTURE AND AIR.

TWO 2.5 PERCENT TAPS ABOVE AND FOUR 2.5 PERCENT TAPS
BELOW NORMAL FULL CAPACITY.

INSULATION CLASS: 220 DEG C, UL-COMPONENT-RECOGNIZED
INSULATION SYSTEM WITH A MAXIMUM OF150 DEG C RISE ABOVE 40 DEG C AMBIENT TEMPERATURE.

ENERGY EFFICIENCY FOR TRANSFORMERS COMPLYING WITH
THE U.S. DEPARTMENT OF ENERGY (DOE) 2016 CFR TITLE 10,
CHAPTER 11, PART 431.

LOW-SOUND-LEVEL REQUIREMENTS: MINIMUM OF 3 DBA LESS
THAN NEMA ST 20 STANDARD SOUND LEVELS WHEN FACTORY
TESTED ACCORDING TO IEEE C57.12.91.

MANUFACTURER: SCHEDULE D, EATON OR APPROVED EQUAL
NAMEPLATES: ENMGRAVED, LAMINATED-PLASTIC OR METAL

NAMEPLATE FOR EACH DISTRIBUTION TRANSFORMER, MOUNTED
WITH CORROSION-RESISTANT SCREWS.

TEST AND INSPECT TRANSFORMERS ACCORDING TO IEEE
C57.12.91. PERFORM VISUAL AND MECHANICAL INSPECTION AND

ELECTRICAL TEST STATED IN NETA
ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE
WITH TEST PARAMETERS.

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

SPECIFICATIONS E1.1

Page 1413 of 1646 ends

MEN WOMEN VENDING QUIET WOMEN MEN CORR. STORAGE CLOSET ASSIST. COORD TRANSIT CONFERENCE DISPATCH SUPV. TRANS. MGR. TRANS. SECRETARY KITCHENET

PANTRY RECEPTION LIFT
Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
ELECTRICAL ADMIN BUILDING 1ST

FLOOR DEMO PLAN
E2.0

Page 1414 of 1646 ends

LIFT WAITING ASSIST. DIR. ACCT. SUPV. SPECIAL SPECIAL PLANNING CORR. COPY WORK OFFICE CLERKS CRC ASLE ELECT ROOM MECH. SHAFT MEN WOMEN STAIR ARCHIVES 1 A10.0
Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
ELECTRICAL ADMIN BUILDING 2ND

FLOOR DEMO PLAN
E2.1

Page 1415 of 1646 ends

LOCKER
SHOWER
LOCKER
SHOWER
STAIRS

BREAK ROOM

MEN'S LOCKERS

MEN'S TOILET

WOMEN'S TOILET
1-2
A11.0

TRAINING ROOM
TOILET
3 A11.0
12 Hall Area B
6 Hall Area A
- A12.0
- A12.0
- A12.0
Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
ELECTRICAL MAINTENANCE & 311
BUILDING 2ND FLOOR DEMO PLAN
E2.2

Page 1416 of 1646 ends

(N)STORAGE Microwave DW
Oven
(E)PRINTER
(N)STORAGE
X
1A2.4
X
1A5.0
X
1A3.0
1A4.0

GFI GFI
GFI
(E) PANEL "A"
(E) PANEL "HA"
(E) PANEL "EA"
+46"
A.F.F.
+46"
A.F.F.
+46"
A.F.F.
+46"
A.F.F.
+46"
A.F.F.
(N) PANEL "C"
C-5
C-5
C-5
C-5
C-7
C-7 C-7 C-7
C-7
C-7
C-7
C-9 C-9 C-9 C-9
C-11
C-11
C-11
C-11
C-11
C-11
C-11
C-11 C-11
C-15 C-15 C-15
C-17 C-19 C-21 C-25
C-9
C-13
C-13 C-13
C-25
C-15
C-15
C-25
C-13
C-23
C-25
C-3
C-3
C-3 C-3
C-3 C-3
C-3 C-3
C-3 C-3
C-3 C-3
C-1
C-1 C-1 C-1
C-1 C-1 C-1
C-1
C-1
C-1
C-1
C-1
C-1
C-3
C-3
C-3
C-3
C-13
C-1 C-1 C-1 C-1
C-1 C-1 C-1 C-1
C-1 C-1 C-1
C-1
C-1
C-1 C-1
C-1
C-1
J OS1 OS1 OS1
OS1
OS1
OS1
OS1
OS1
OS1
OS1
OS1
LD
ELD
LD LD

LD ELD LD LD

LD LD LD LDE
LD

LD LD ELD LD LD

LD ELD LD LD LD

LD LD LD ELD LD
X1
X2
C-1
OS1
OS1
OS1
OS1
OS1
OS1
C-3
L4GE
L4G
L4G L4G
L4G
L4G L4GE L4G
L4G L4GE
L4G
L4GE
L4GE
L4GE
L4G
J
C-3
L4GE
L4G
D
D
D
D
D C-3
C-1
C-1
C-1
C-3
C-1
C-1
C-1
C-1 C-1 C-1
L1 L1
L1
L1
L1 L1E L1 L1E
L1E L1E
L1E
L1E
C-7 C-32
J UPS
C-18

GFI GFI GFI GFI GFI
C-1
L3
C-1
L3
C-1
L3
C-1
L3
L1
L1
L1
L1
C-1
C-1
C-1
C-1
J
C-18
J
C-20
J
C-22
C-1
Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA

ELECTRICAL ADMIN BUILDING
1ST FLOOR NEW PLAN
E3.0

Page 1417 of 1646 ends

1 1A7.0
+46"
A.F.F.

GFI GFI
(E)
PANEL
"2A"
(E)
PANEL
"H2A"
+46"
A.F.F.

GFI
GFI
GFI
GFI
GFI
C2-26
C2-6
C2-6 C2-6
C2-6
C-8
C-10
C2-6
C2-6 C-8
C-10
C-8
C-8
C2-12 C2-12 C-10 C-14 C-16 C-10
C-8
C-12
C-10
C-8
C-8
C-12
C-12
C2-10
LD
LD
LDE
LD
LD
LD
LDE
LD
LD

LD LD ELD LD LD
LD
LD
ELD
C-2 C-2
C-2
C-2
C-2
C-28
C-2
C-30 C-2 C-2 C-2 C-2 C-2
GFI
+46"
A.F.F.

C-4 C-4
C-4 C-4
C-4
C-4
L4GE
L4G
L4G L4G
L4GE
J
J
C-2
C-4
C-2
LDE
LDE

LDE LDE
LD
LD
LD

LD LD LD
C-2
C-2
C-2
C-2
C-2
C-2 C-2
C-2
C-2 C-2 C-2
LD
LD
OS1
OS1
D
OS1 OS1
C-2
C-2
S
C-2
C-2
S
C-2 S
C-2
C-2
D
OS1 OS1
OS1 OS1
OS1 OS1
C-4
OS1 OS1 OS1 OS1
C-4
C-2
C-2 C-2
C-4 C-4 C-4
L1
C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4
C-4
C-4
C-4
OS1
L1 L1E L1 L1E
L1G L1G L1GE L1G L1G L1GE
L1G L1G
L1GE
L1G L1G L1GE L1G L1G L1G L1GE
L1G
L1GE
L1G
L1GE
L1G
L1G L1GE
L1G L1G
L1GE L1G
L1G
L1GE
L1G
L1G L1G
L1G
C-4
C-4 C-4
C-4 C-4
C-4 C-4
C-4 C-4
C-4 C-4
L1G
L1G
C-4
C-4
C-4 C-4
C-4
C-4 C-4
C-4
L2
L2
L2
L2
L2
L2
L2 L2
C-6
C2-6
C2-2
C-2 L3
L3
L3
L3
C-2
C-2
TYP.

L3
C-2
L3
C-2
C-2
L1G
C-4
L1G
C-4
L1G
C-4
C-4
Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
ELECTRICAL ADMIN BUILDING 2ND

FLOOR NEW PLAN
E3.1

Page 1418 of 1646 ends

LDE
LDE
LD
LDE
S
OS
OS
J
LD LD
LD
LD
LD LD
LDE

LD LDE LD

TRAINING ROOM
L4G L4GE L4G
L4GE L4G L4G
L4G L4G
L4GE
46"
A.F.F.

GFI
OS D
OS
J
J
GFI
LDE
LD
S
J
LDE LD
LD
LDE
LDE
LDE
LD
LD

LD LD LDE

LD LDE LD

LD LD LDE
J
J
S
OS
OS
LD LDE
LDE LD
J
S
OS
LD LDE
J
S
OS
LD

LD LD LDE

LD LD LDE
LD LDE
LD LD
J
OS OS
S
LD
LDE LD
LD
LD
LD
LD
LD
LD
LD LDE
LD
S
OS OS
J
LD
LD
LDE
LD
LDE
LD
LD
LD
LDE LD

LDE LDE
LD
LD
S
J
LD
LDE LD
LD
STAIRS

BREAK ROOM
1 A8.0
L4G L4G
L4G L4G
L4G
L4GE
L4GE
L4GE

GFI GFI GFI GFI
D
OS
D
OS
J
J
TV
Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
ELECTRICAL MAINTENANCE & 311 &

FUEL ISLAND NEW PLANS
E3.2

Page 1419 of 1646 ends

Xref .\x101229-TBLK-E.dwg
Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE: Department of Public Works

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
iArch
iArch
iArch

INFRASTRUCTURE ARCHITECTS
100 Progress,Suite 110,Irvine,CA 92618
www.infrastructurearchitects.com
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
iARCH

CITY OF MONTEBELLO TRANSPORTATION FACILITY CENTER REMODEL

ENGINEERING GROUP
ARIA
1 AC
2 AC
3 AC
4 AC
5 AC
TYPE
LD
LDE
L4G
L4GE
X1
X2

LIGHTING FIXTURE SCHEDULE

DESCRIPTION MANUFACTURER AND MODEL
NUMBER

VOLT LAMP INPUT WATTS RECESSED REMARKS

LED DOWNLIGHT DIMMABLE

LED DOWNLIGHT DIMMABLE WITH

EMERGENCY BATTERY PACK
LED DECORATIVE 2'X4' DIMMABLE

LIGHT FIXTURE WITH EMERGENCY

BATTERY PACK
LED DECORATIVE 2'X4' DIMMABLE

LIGHT FIXTURE WITH EMERGENCY

BATTERY PACK

SINGLE FACE LED EXIT SIGN WITH

EMERGENCY BATTERY PACK

DOUBLE FACE LED EXIT SIGN WITH

EMERGENCY BATTERY PACK

LITHONIA
# LDN4 35/15 L04 AR LSS TRW
MVOLT GZ10

LITHONIA
# LDN4 35/15 L04 AR LSS TRW
MVOLT GZ10 E10WCP

LITHONIA
# 2BL T4 48L ADSM MVOLT
GZ10 LP835

LITHONIA
# 2BL T4 48L ADSM MVOLT GZ10
LP835 E10WLCP

LITHONIA
# LQM S W 3 G 120/277 ELN

LITHONIA
# LQM S W 3 G 120/277 ELN
120/277V
120/277V
120/277V
120/277V
120/277V
120/277V
1500 LUMEN LED
1500 LUMEN LED
4800 LUMEN LED
4800 LUMEN LED
LED
LED

17.5 W

17.5 W
38 W
38 W
5 W
5 W

RECESSED

RECESSED

RECESSED IN

GRID CEILING

RECESSED IN

GRID CEILING

SURFACE

SURFACE
L1G
L1GE
LED DECORATIVE 11'' x 11" DIMMABLE

LIGHT FIXTURE WITH EMERGENCY

BATTERY PACK
120/277V
120V 2063 LUMEN LED
20 W
20 W

RECESSED IN

GRID CEILING

RECESSED IN

GRID CEILING
L1 LED LINEAR RECESSED ALCON
12500-20-S-D-D4-S4-35K-010-8-FL-EM5 120/277V 4.5 W

RECESSED IN

GRID CEILING
L1E
LED DECORATIVE 11'' x 11" DIMMABLE

LIGHT FIXTURE
L2
LED 4' LINEAR RECESSED

BATTERY PACK
ALCON
12500-20-S-D-D4-S4-35K-010-8-FL-EM5 120/277V 4.5 W

RECESSED IN

GRID CEILING
LUMENS
COLOR TEMP. 3500K - CRI 90

COMPATIBLE WITH ELV DIMMING
LUMENS
COLOR TEMP. 3500K - CRI 90

COMPATIBLE WITH ELV DIMMING

LED PANDANT
LUMENS
COLOR TEMP. 3500K - CRI 90

COMPATIBLE WITH ELV DIMMING
2063 LUMEN LED
120V 160 LUMEN LED 3 W

PENDANT IN

GRID CEILING
SINGLE LINE DIAGRAM E4.0
L3 LED LINEAR LUMENS
COLOR TEMP. 4000K - CRI 80 12VDC 4.4W /FT RECESSED IN
GRID CEILING 304/FT

Page 1420 of 1646 ends

1) 2022 CALIFORNIA BUILDING CODE.
2) 2022 CALIFORNIA RESIDENTIAL CODE.
3) 2022 CALIFORNIA MECHANICAL CODE.
4) 2022 CALIFORNIA PLUMBING CODE.
5) 2022 CALIFORNIA ELECTRICAL CODE.
6) 2022 CALIFORNIA ENERGY CODE
7) 2022 CALIFORNIA GREEN BLDG STANDARDS
REFERENCE CODES
PLUMBING SYMBOLS
L-1
RPBFP
FLOOR DRAIN, AREA DRAIN
ROOF DRAIN, OVERFLOW DRAIN
HOSE BIBB
CHECK VALVE
BALANCING VALVE
AIR RELIEF VALVE
VALVE IN YARD BOX
GAS COCK
SHUT-OFF VALVE
PRESSURE GAUGE WITH PET COCK
FLEXIBLE CONNECTOR
FLOOR SINK

THERMOMETER

STRAINER
UNION

REDUCER
VALVE ON RISER
SOLENOID VALVE (ELECTRIC)
DIRECTION OF FLOW
PLUGGED OUTLET
PIPING BREAK
HUB DRAIN, FUNNEL DRAIN
CLEANOUT (CO)
PIPING DOWN
BRANCH CONNECTION
PIPING RISE OR DROP
PIPING UP
FLOOR CLEANOUT IN YARDBOX
TEE DOWN CONNECTION
(E)
GW
RD
G
2PSI
TP
VAC
AIR
MED
ORD
COLD WATER
HOT WATER
HOT WATER RETURN
SANITARY BELOW GRADE
SANITARY ABOVE GRADE
EXISTING PIPING
GREASE WASTE
ROOF DRAIN
OVERFLOW ROOF DRAIN
SANITARY VENT
MEDIUM PRESS. NATURAL GAS
LOW PRESSURE NATURAL GAS
TRAP PRIMER SUPPLY
PIPE TO BE DEMOLISHED
VACUUM
COMPRESSED AIR
MEDGAS
TYPICAL FIXTURE DESIGNATION
REDUCED PRESSURE BACKFLOW
PREVENTER (RPBFP)
WATER HAMMER ARRESTER
BEHIND ACCESS PANEL
TRAP PRIMER BEHIND ACCESS
PANEL
TEMPERATURE/PRESSURE RELIEF
VALVE & PRESSURE RELIEF VALVE
POINT OF CONNECTION
M WATER METER
HWR
HB
HP
HW
GPF
GAL
GPM
G
HOT WATER RETURN (DOMESTIC)
GALLONS PER FLUSH
GAS (LOW PRESSURE)
GALLONS PER MINUTE
HOSE BIBB

HORSEPOWER
HOT WATER (DOMESTIC)
GALLON
EL
FD
FFE
FLR
FT
FU
FV
FCO
EQUIP
EWC
DR
DS
(E)
COTG
CW
DN

ELEVATION
ELECTRIC WATER COOLER
FLOOR CLEANOUT
FINISHED FLOOR ELEVATION
FLOOR DRAIN
FLOOR
FOOT, FEET
FIXTURE UNIT
FLUSH VALVE

EQUIPMENT
CLEANOUT TO GRADE
DROP
DOWN SPOUT

EXISTING
COLD WATER (DOMESTIC)
DOWN
CFH
CFM
CLG
CONT
CO
BEH
BEL
CD
AC
ABV
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
CONDENSATE DRAIN

CONTINUATION

CEILING

CLEANOUT
BEHIND
BELOW
AIR CONDITIONING (HVAC)
ABOVE
WATER CLOSET
WATER HAMMER ARRESTOR
WALL HYDRANT
WALL CLEANOUT
WH
WHA
WC
W
W/
WCO
VERT
UR
WITH
WASTE

VERTICAL
URINAL
VENT
THERMOSTATIC MIXING VALVE
TRAP PRIMER
REVOLUTIONS PER MINUTE
SANITARY SEWER
SHUT-OFF VALVE
STORM DRAIN
POUNDS PER SQUARE INCH
ON CENTER
TEMPERED WATER
TMV
TYP
TP
TW
SAN
SK
RPM
SD
SOV

TYPICAL
SINK
PSI
QTY
PH
OC

QUANTITY
PHASE
INVERT ELEVATION
INDIRECT WASTE
INDUSTRIAL COLD WATER
NORMALLY CLOSED
NORMALLY OPEN
NOT TO SCALE
MPG
NTS
NC
NO
LAV
MEDIUM PRESSURE GAS

LAVATORY
IW
ICW
IE
AP ACCESS PANEL

MTD MOUNTED
OD OVERFLOW DRAIN
PO PLUGGED OUTLET
VTR VENT THROUGH ROOF
VB VACUUM BREAKER
AV ACID VENT
AW ACID WASTE
BTUH BRITISH THERMAL UNITS PER HOUR
CU FT CUBIC FEET
DF DRINKING FOUNTAIN
ESEW EMERGENCY SHOWER EYE WASH
GPH GALLONS PER HOUR
GPR GAS PRESSURE REGULATOR
GWH GAS WATER HEATER
AFF ABOVE FINISH FLOOR
TWR TEMPERED WATER RETURN
AFSR AUTOMATIC FIRE SPRINKLER RISER
YB YARD BOX
POC POINT OF CONNECTION
GC GAS COCK

ACC ACCESSIBLE
F FIRE LINE
GW GREASE WASTE
TPL TRAP PRIMER LINE
V
-  A  -
-  B  -
-  C  -
-  D  -
-  E  -
-  F  -
-  G  -
-  H  -
-  I  -
-  K  -

INT INTEGRAL

KW KILOWATT
-  L  -
-  M  -
-  N  -
-  O  -
-  P  -
-  Q  -
-  R  -
-  S  -
-  T  -
-  U  -
-  V  -
-  W  -
-  Y  -

DWG DRAWING
RD ROOF DRAIN
FS FLOOR SINK
SS SERVICE SINK

SQ SQUARE
MS MOP SINK
HD HUB DRAIN
EWH ELECTRIC WATER HEATER
DW DISH WASHER

REF REFRIGRATOR
PLUMBING ABBREVIATIONS PLUMBING SPECIFICATIONS
X
XX

KEYNOTES
XXX
SYMBOL OR TYPE (SEE

SCHEDULE
OR SPECIFICATIONS)
IDENTIFICATION NUMBER
(SEE SCHEDULE)
FLOOR CLEANOUT, EXTERNAL
FLOOR CLEANOUT
UNDERGROUND COLD WATER
UNDERGROUND HOT WATER

UNDERGROUND
HOT WATER RETURN
PART­I
G E N E R A L

1.01   RELATED DOCUMENTS:

A.   THE GENERAL REQUIREMENTS OF THE ARCHITECTURAL SPECIFICATIONS ARE PART OF THESE SPECIFICATIONS. WHERE AN INCONSISTENCY EXISTS BETWEEN THE WORDING OR INTENT, THIS SECTION SHALL TAKE PRECEDENCE. THE STANDARD FORM OF "GENERAL CONDITIONS" ISSUED BY THE AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT A201, LATEST EDITION, SHALL FORM PART OF THIS CONTRACT.

B.   CONTRACT DOCUMENTS MAY INCLUDE, BUT NOT LIMITED TO THE FOLLOWING: ARCHITECTURAL, STRUCTURAL, ELECTRICAL, MECHANICAL, FIRE PROTECTION, AND CIVIL.

1.02 DEFINITIONS:

A.   TERMINOLOGY: AS DEFINED IN MSS SP-90, "GUIDELINES ON TERMINOLOGY FOR PIPE HANGERS AND SUPPORTS."
B.   WATER DISTRIBUTION PIPING: INTERIOR DOMESTIC WATER PIPING.

C.   WATER SERVICE: EXTERIOR DOMESTIC WATER PIPING.

D.   ACCESSIBLE FIXTURE: PLUMBING FIXTURE THAT CAN BE APPROACHED, ENTERED, AND USED BY PEOPLE WITH DISABILITIES.

1.03 PERFORMANCE REQUIREMENTS:

A.   DESIGN SUPPORTS FOR MULTIPLE PIPES CAPABLE OF SUPPORTING COMBINED WEIGHT OF SUPPORTED SYSTEMS, SYSTEM CONTENTS, AND COMPONENTS.

B.   DESIGN EQUIPMENT SUPPORTS CAPABLE OF SUPPORTING COMBINED OPERATING WEIGHT OF SUPPORTED EQUIPMENT AND CONNECTED SYSTEMS AND COMPONENTS.

C.   DESIGN SEISMIC-RESTRAINT (IF APPLICABLE) HANGERS AND SUPPORTS FOR PIPING AND EQUIPMENT, AND OBTAIN APPROVAL FROM AUTHORITIES HAVING JURISDICTION.

D.   COMPONENTS AND INSTALLATION SHALL BE CAPABLE OF WITHSTANDING THE  WORKING PRESSURE.

1.04 SUBMITTALS:

A.   CONTRACTOR SHALL SUBMIT FOR REVIEW TO THE ARCHITECT/ENGINEER A COMPLETE LIST OF ITEMS TO BE FURNISHED AND INSTALLED UNDER THIS CONTRACT.  INCLUDING, BUT NOT BE LIMITED TO THE FOLLOWING:

1.1. DIMENSIONED SHOP DRAWINGS OF MATERIALS, FIXTURES AND EQUIPMENT.

1.2. DIMENSIONED SHOP DRAWINGS OF EQUIPMENT AND PIPING PLAN LAYOUT(S).

1.3. PRODUCT DATA.

1.4. FIELD-QUALITY CONTROL INSPECTION AND TEST REPORTS

1.5. FIELD TEST CERTIFICATES.

1.6. OPERATION AND MAINTENANCE DATA.

1.7. EQUIPMENT MANUALS.

1.8. VALVE TAGS.

1.9. WELDING CERTIFICATES.

B.   ANY DEFERRED CONTRACTOR SUBMITTALS OR CALCULATIONS REQUIRED BY THE LOCAL AHJ, IN ORDER TO OBTAIN OCCUPANCY SHALL BE PROVIDED THE PLUMBING CONTRACTOR. ALL SUBMITTALS SHALL BE PREPARED BY A LICENSED PROFESSIONAL ENGINEER, LICENSED IN THE PROJECT JURISDICTION, AS REQUIRED BY THE LOCAL AHJ. THE CONTRACTORS ENGINEER SHALL PREPARE PLANS, CUT SHEETS, CALCULATIONS, ETC. AS REQUIRED. ALL DEFERRED SUBMITTALS SHALL BE SIGNED AND STAMPED BY THE PREPARING ENGINEER. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ANY FEES REQUIRED FOR SUCH SUBMISSION IN HIS BID.

C.   CONTRACTOR AND/OR MANUFACTURER SHALL VERIFY THAT THE CHARACTERISTICS OF THE EQUIPMENT HE SUBMITS FOR REVIEW MEETS THE CAPACITY,INSTALLATION AND DUTY SPECIFIED.

1.05 CODES AND STANDARDS:

APPLICABLE CODES:

1.1. LOCAL PLUMBING CODE.

1.2. LOCAL DEPARTMENT OF PUBLIC HEALTH.

1.3. LOCAL AMENDMENTS TO PLUMBING CODE.

1.4. LOCAL ORDINANCES.

1.06 QUALITY ASSURANCE:

A.   WELDING: QUALITY PROCEDURES AND PERSONNEL ACCORDING TO ASME BOILER AND PRESSURE VESSEL CODE: SECTION IX.

B.   FIRE TEST RESPONSE CHARACTERISTICS: INSULATION AND RELATED MATERIALS SHALL HAVE FIRE TEST RESPONSE CHARACTERISTICS INDICATED, AS DETERMINED BY TESTING IDENTICAL PRODUCTS PER ASTM E 84, BY A TESTING AND INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.

FACTORY LABEL INSULATION AND JACKET MATERIALS AND ADHESIVE, MASTIC, AND CEMENT MATERIAL CONTAINERS, WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING AGENCY.

1.1. INSULATION INSTALLED INDOORS: FLAME SPREAD INDEX OF 25 OR LESS, AND SMOKE DEVELOPED INDEX OF 50 OR LESS.

1.2. INSULATION INSTALLED OUTDOORS: FLAME SPREAD INDEX OF 75 OR LESS, AND SMOKE DEVELOPED INDEX OF 150 OR LESS.

C.   PIPING MATERIALS SHALL BEAR LABEL, STAMP, OR OTHER MARKINGS OF SPECIFIED TESTING AGENCY.

D.   ASME COMPLIANCE:

1.1. ASME B31.9 FOR BUILDING SERVICES PIPING VALVES.

1.2. ASME COMPLIANCE FOR FERROUS VALVES: ASME B16.10 AND ASME B16.34 FOR DIMENSION AND DESIGN CRITERIA.

E.   NSF COMPLIANCE:

1.1. NSF 14, "PLASTIC PIPING SYSTEM COMPONENTS AND RELATED MATERIALS."

1.2. NSF 61, "DRINKING WATER SYSTEM COMPONENTS - HEALTH EFFECTS; SECTIONS 1 THROUGH 9." F.   ELECTRICAL COMPONENTS, DEVICES AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE.

G.   REGULATORY REQUIREMENTS:

1.1. COMPLY WITH PUBLIC LAW 101-336, "AMERICAN WITH DISABILITIES ACT," AND "UNIFORM FEDERAL ACCESSIBILITY STANDARDS."

1.2. COMPLY WITH PUBLIC LAW 102-486, "ENERGY POLICY ACT."

1.07 LAWS AND ORDINANCES:

CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES,   RULES AND REGULATIONS BEARING ON THE CONDUCT OF WORK AS SHOWN ON DRAWINGS AND SPECIFIED HEREIN. IF CONTRACTOR OBSERVES THAT THE DRAWINGS AND SPECIFICATIONS ARE AT VARIANCE THEREWITH, CONTRACTOR SHALL PROMPTLY NOTIFY ARCHITECT/ENGINEER IN WRITING WHEN SUBMITTING BID AND ANY NECESSARY CHANGES SHALL BE ADJUSTED AS PROVIDED IN THE CONTRACT FOR SUCH CHANGES IN WORK.

IF CONTRACTOR PERFORMS ANY WORK, CONTRARY TO SUCH LAWS, ORDINANCES, RULES & REGULATIONS, CONTRACTOR SHALL BEAR ALL COSTS FOR CORRECTING THE WORK.

1.08 GUARANTEE:

CONTRACTOR SHALL GUARANTEE WORK TO BE FREE FROM DEFECTIVE WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL CERTIFICATE. ANY REPAIRS OR REPLACEMENT DURING THIS PERIOD SHALL BE MADE WITHOUT COST TO THE OWNER, UPON OWNER'S REQUEST.

PART­II
E X E C U T I O N

2.01   GENERAL NOTES, FIXTURES, & VALUES :

A. DESIGN AND CONSTRUCT COMPLETE PLUMBING SYSTEM CONSISTING OF DRAIN. VENT WASTE AND WATER LINES IN COMPLIANCE WITH ALL APPLICABLE STATE LOCAL AND FEDERAL LAWS, CODES AND REGULATIONS. COMPLY WITH ARCHITECTURAL WORKING DRAWINGS FOR LOCATIONS OF ALL PLUMBING FIXTURES,TRIM AND RELATED ITEMS.

B. PERMITS AND INSPECTIONS,SHALL BE OBTAINED BY THIS CONTRACTOR AS REQUIRED BY LIMITS OF THE WORK DEFINED HEREIN AND BY APPLICABLE CODES AND REGULATIONS.

C. DESIGN DRAWINGS SHALL BE PREPARED BY THIS CONTRACTOR IN COMPLIANCE WITH THE PROJECT DESIGN AND IN COMPLIANCE WITH ALL APPLICABLE CODE REQUIREMENTS. SUBMIT PLUMBING DESIGN ISOMETRIC DRAWINGS TO THE BUILDING DEPARTMENT FOR APPROVAL AS PER THEIR REQUIREMENTS.

D. PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODES AND SHALL MEET THE APPLICABLE STANDARDS OF THE CALIFORNIA PLUMBING CODE.

E. PLUMBING FIXTURES SHALL BE LISTED IN CONFERENCE WITH CPC 2022.

F. HOT MOPPED SHOWER PAN SHALL BE INSPECTED UPON COMPLETION OF HOT-MOPPING AND SHALL BE FILLED WITH WATER FOR INSPECTION. CPC 2022.CIRCULATING HOT WATER SYSTEMS SHALL BE FULLY INSULATED AND SHALL HAVE CONTROL (TIME CLOCK) CAPABLE OF AUTOMATICALLY TURNING OFF THE CIRCULATING PUMP(S) WHEN HOT WATER IS NOT REQUIRED.

WATER CLOSETS, URINALS,SHOWER HEADS, LAVATORY FAUCETS AND SINK FAUCETS SHALL MEET THE FLOWING REQUIREMENTS OUTLINED IN THE TITLE 24 "APPLIANCE EFFICIENCY STANDARDS".

WATER CLOSETS 1.28 GPF
URINALS 0.125 GPF (WALL MOUNTED)
URINALS 0.5 GPF (OTHERS)
SHOWER HEADS 1.8 GPM @ 80 PSI
LAVATORIES 1.2 GPM @ 60 PSI
SINKS 1.8 GPM @ 60 PSI
METERING FAUCETS 0.20 gallons per cycle
NOTES: LAVTORY FAUCETS SHALL NOT HAVE FLOW RATE LESS THAN 0.8 GPM G. FOR ADDITIONS OR IMPROVEMENTS TO A RESIDENCE BUILT BEFORE 1994,EXISTING "NONCOMPLIANT" FIXTURES (TOILETS THAT USE MORE THAN 1.6 GALLONS OF WATER PER FLUSH, URINALS THAT USE MORE THAN ONE GALLON OF WATER PER FLUSH, SHOWERHEADS THAT HAVE A FLOW CAPACITY OF MORE THAN 2.5 GALLONS OF WATER PER MINUTE,AND INTERIOR FAUCETS THAT EMIT MORE THAN 2.2 GALLONS OF WATER PER MINUTE) SHALL BE REPLACED. CERTIFICATION OF COMPLIANCE SHALL BE GIVEN TO THE BUILDING INSPECTOR PRIOR TO FINAL PERMIT APPROVAL. CALIFORNIA SB407.

H. SHOWER AND TUB/SHOWER CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING TYPE. HANDLE POSITION SPOTS SHALL BE PROVIDED ON THESE VALVES AND SHALL BE ADJUSTED TO DELIVER A MAXIMUM WATER SETTING OF 120 AS PER CPC 2022.

I. PROVIDE ALL VALVES AS REQUIRED. SWEAT COPPER ENDS ON COPPER PIPING SYSTEMS,SCREWED ENDS ON STEEL SYSTEMS. USE SQUARE HEAD COCKS ON FUEL. GAS SYSTEMS.PROVIDE SPEEDWAY STOPS ON ALL FIXTURES.

J. WATER PRESSURE REGULATORS SHALL BE INSTALLED   ON THE WATER SERVICE PRIOR TO CONNECTION TO BUILDING IF PRESSURE EXCEEDS 80 PSI AS PER CPC 2022.

K. HANGERS AND SUPPORTS SHALL BE BY A RECOGNIZED MANUFACTURER SPECIALIZING IN THESE PRODUCTS, SUCH AS MCO, BLINE, ETC
L. IN SHOWERS & TUB-SHOWER COMBINATIONS , CONTROL VALVES MUST BE PRESSURE BALANCED OR THERMOSTATIC MIXING VALVES AS PER CPC 2022.

M. WATER SYSTEM SHALL BE STERILIZED USING CHLORINE SOLUTION, TESTED AND CERTIFICATION PROVIDED FROM APPROVED TESTING FACILITY.

N. ALL SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE APPLICABLE SECTIONS OF CALIFORNIA BUILDING CODE AND WITNESSED BY THE LOCAL BUILDING AUTHORITY AND OWNERS REPRESENTATIVE.

O. ALL HOSE BIBBS AND FAUCETS FITTED WITH THREADED CONNECTIONS SHALL BE FITTED WITH AN APPROVED NON-REMOVABLE BACK FLOW DEVICE PER CPC 2022 P. BUILT-UP SHOWER RECEPTORS SHALL BE INSTALLED AND INSPECTED UPON COMPLETION OF WATER PROOFING AS PER CPC 2022.

Q. COUNTERSINK PLUG TO BE INSTALLED WHERE RAISED HEADS CAUSE A HAZARD.

R. CONDENSATE SHALL BE COLLECTED AND DISCHARGED TO AN APPROVE PLUMBING FIXTURES OR  APPROVED DISPOSAL AREA. REFER TO UMC SECTION 310 FOR ADDITIONAL REQUIREMENTS FOR CONDENSATE DRAINAGE PIPING.

S. APPROVED SPARK ARRESTORS SHALL BE INSTALLED ON ALL CHIMNEYS AS PER CBC 2022.

2.02 WATER HEATERS:

A. WATER HEATERS SHALL BE EQUIPPED WITH A COMBINATION PRESSURE AND TEMPERATURE RELIEF VALVE AT ALL WATER HEATERS, SET TO OPEN AT NOT MORE THAN 150 PSI. DRAIN PIPE SHALL EXTEND TO OUTSIDE OF BUILDING AND TERMINATE NOT MORE THAN 2 FEET NOT LESS THAN 6 INCHES ABOVE THE GROUND AND POINT DOWNWARD WITH THE END UNOBSTRUCTED.

ANY OTHER TERMINATION LOCATION SHALL REQUIRE APPROVAL BY THE BUILDING OFFICIAL AS PER CPC 2022.

B. DOMESTIC WATER HEATERS SHALL BE CERTIFIED AND LISTED BY THE CALIFORNIA ENERGY COMMISSION. EXTERIOR INSULATION SHALL BE R-16, OR GREATER. THE FIRST 5 FEET OF EXPOSED HOT AND COLD WATER PIPING AND THE WATER HEATER SHALL BE INSULATED. AS PER TITLE 24.

C. PROVIDE A R-12 WATER HEATER BLANKET FOR ALL WATER HEATERS.

D. WATER HEATERS LOCATED IN ATTIC OR FURRED SPACE WHERE DAMAGE MAY RESULT FROM LEAKING WATER HEATERS SHALL BE INSTALLED IN OR OVER A WATER TIGHT PAN WITH A 3/4 INCH DRAIN TO AN APPROVED LOCATION AS PER CPC 2022.

E. IN SEISMIC DESIGN CATEGORIES D & E WATER HEATER SHALL BE ANCHORED OR STRAPPING SHALL BE AT POINT WITHIN THE UPPER ONE-THIRD (1/3) AND LOWE ONE-THIRD (1/3) OR ITS VERTICAL DIMENSIONS AT THE LOWER POINT, A MINIMUM DISTANCE OF FOUR (4) INCHES SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRIPPING. (CPC 2022).

F. ALL HOT WATER PIPES RUN FROM  THE HEATING SOURCE TO THE KITCHEN FIXTURES SHALL INCLUDE A MINIMUM OF 1 INCH INSULATION." (CALIFORNIA ENERGY CODE) G. PROVIDE MINIMUM R-12 INSULATION FOR SMALL STORAGE WATER HEATERS WITH AN INPUT RATING LESS THAN OR EQUAL TO 75,000 BTU/HR. (CALIFORNIA ENERGY CODE) H. THE ENTIRE LENGTH OF RE-CIRCULATING DISTRIBUTION SECTIONS OF DOMESTIC WATER SYSTEMS SHALL BE INSULATED, REGARDLESS OF WHETHER THE PIPING IS BURIED OR EXPOSED." (CALIFORNIA ENERGY CODE)
I. REQUIREMENT FOR GAS WATER HEATER INSTALLED TO SERVE INDIVIDUAL DWELLING UNITS ES150.0(N)
I.1. A CONDENSATE DRAIN INSTALLED NO HIGHER THAN 2" ABOVE THE BASE OF THE HEATER THAT ALSO ALLOWS FOR GRAVITY DRAINAGE
I.2. THE "B" VENT INSTALLED IN A STRAIGHT POSITION (NO BENDS) FROM THE ROOM CONTAINING THE WATER HEATS TO THE ROOF TERMINATION (FOR FUTURE POSSIBLE SLEEVING FOR HIGH EFFICIENCY HEATER VENTING).

I.3. A 120 VOLT RECEPTACLE ACCESSIBLE TO THE HEATER INSTALLED WITH  TO 3'-0".

2.03 PIPING:

A. INSTALLATION OF ALL PIPING SYSTEMS SHALL BE IN ACCORDANCE WITH APPLICABLE IAPMO INSTALLATION STANDARDS AND LISTED IN CPC APPENDIX 1.

B. SOLDER SHALL BE LEAD FREE COMPLYING WITH THE PROVISIONS OF FEDERAL CLEAN DRINKING WATER ACT AND THE CPC 2022.

C. 50/50 SOLDER JOINTS AREA NO LONGER PERMITTED IN PORTABLE WATER DISTRIBUTION SYSTEMS. ONLY 95/5 SOLDER JOINTS ARE PERMISSIBLE.

D. INFORMATIONAL,FOR THE PURPOSES OF THIS SECTION ,"LEAD FREE" MEANS NOT MORE THAN

0.2 PERCENT LEAD WHEN USED WITH RESPECT TO SOLDER AND FLUX AND NOT MORE THAN 8PERCENT WHEN USED WITH RESPECT TO PIPES AND PIPE FITTINGS WITH RESPECT TO PLUMBING FITTING AND FIXTURES, "LEAD FREE" MEANS NOT MORE THAN 4 PERCENT BY DRY WEIGHT.

E. SUPPORT ALL LINES BY MEANS OF RESILENT FITTING OR ACCESSORIES, DO NOT ALLOW PIPING TO BE IN DIRECT CONTACT WITH FRAMING.

F. NO COPPER PIPING SHALL BE IN CONTACT WITH ANY METAL OTHER THAN COPPER.

G. PIPING SYSTEMS SHALL BE SECURELY SUPPORTED TO PREVENT UNDUE MOVEMENT AND SWAYING BUT FLEXIBLE ENOUGH TO PERMIT EXPANSION.

H. ALL HOT WATER SUPPLY & RETURN PIPING SHALL BE INSULATED AS FOLLOWS (CPC 609.12.2):
a. 1” INSULATION THICKNESS REQUIRED FOR 3/4” PIPE.
b. 1-1/2” INSULATION THICKNESS REQUIRED FOR 1” TO 1-1/2” PIPE. c. 2” INSULATION THICKNESS REQUIRED FOR 2” PIPE & LARGER.

I. BELOW GRADE HOT WATER PIPING IS REQUIRED TO BE INSTALLED IN A WATERPROOF AND NON -CRUSHABLE SLEEVE OR CASING THAT ALLOWS FOR REPLACEMENT OF BOTH THE PIPING AND INSULATION PLEASE NOTE OR SHOW THIS ON THE PLANS.

J. DRAIN PIPING SHALL SLOPE AT 2% OR 1/4 INCHES PER FOOT FOR BELOW 2-1/2" OR LESS PIPING UNLESS OTHERWISE NOTED. GREATER THAN3' AND LESS THAN 6" PIPING REQUIRING SLOPE  1% OR 1/8 INCHES PER FOOT. THE PIPE GREATER THAN 6" REQUIRE K. 1/16" SLOPE. THE INSTALLATION CONDITIONS SHALL BE NOTED ON THE PLANS AND APPROVAL RECEIVED FROM THE ADMINISTRATIVE AUTHORITY PER CPC 2022.

L. CONDENSATE SHALL BE COLLECTED AMP DISCHARGED TO AN APPROVED DISPOSAL AREA.

REFER TO CPC 2022 FOR ADDITIONAL REQUIREMENTS FOR CONDENSATE DRAINAGE PIPING.

M. F.M.C.O. SHALL OPEN IN A DIRECTION OPPOSITE TO THE FLOW OF THE WASTE ABOVE PIPE F.L N. PROVIDE MINIMUM CLEARANCE  OF NOT LESS THAN 18" IN FRONT OF CLEAN OUT.

O. ALL SOIL WASTE AND VENT LINES SHALL COMPLY WITH UNIFORM PLUMBING CODE, SOIL AND WASTE BEYOND THE FIVE FOOT BUILDING LINE SHALL BE VITRIFIED CLAY PIPE WITH SPEED SEAL JOINTS OR TRANSIT SEWER PIPE WITH RING GROOVE COUPLINGS.

P. COLD AND HOT WATER LINES ABOVE GRADE SHALL BE TYPE M HARD DRAWN COPPER WITH 50-50 SOLDER JOINTS. COLD WATER LINES BELOW GRADE SHALL BE TYPE L COPPER WITH 95-5 SOLDER JOINTS FROM WATER METER.

Q. FLOOR DRAINS AND FLOOR SINKS WHICH ARE SUBJECT TO INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC METHOD OF MAINTAINING TRAP SEALS AS PER CPC 2022.

R. A MINIMUM OF 12" ACCESS PANEL TO BATHTUB TRAP CONNECTIONS SHALL BE INSTALLED WHEN SLIP JOINT CONNECTIONS ARE USED AS PER CPC 2022.

S. NO GAS PIPING SHALL BE INSTALLED UNDERGROUND BENEATH ANY BUILDING SLAB ON GRADE OR STRUCTURE UNLESS INSTALLED IN A GAS TIGHT CONDUIT. INCLUDING PIPING UNDER COVERED PATIOS [CPC 2022]
T. NO GAS PIPE SHALL BE INSTALLED UNDER THE BUILDING PATIO COVER U. UNDERGROUND PLASTIC GAS PIPING SHALL BE 18" DEEP AND THE TRANSITION RISER MUST COMPLY WITH CPC 2022.

V. AN ELECTRICALLY CONTINUOUS CORROSION-RESISTANT TRACER WIRE (MINIMUM AWG 14) OR TAE SHALL BE BURIED WITH THE PLASTIC PIPE TO FACILITATE LOCATING. ONE (1) END SHALL BE BROUGHT ABOVE GROUND AT A BUILDING WALL OR RISER. [NFPA 54:1.133]

2.04 VENTS
W. EACH VENT SHALL NOT TERMINATE NOT LESS THAN 10' FEET FROM OR AT LEAST 3' FEET ABOVE, AN OPPERABLE WINDOW DOOR, OPENING, AIR INTAKE, OR VENT SHAFT, OR NOT LESS THAN 3 FEET  IN EVERY DIRECTION FROM A LOT LINE ALLEY AND STREET EXPECTED.

X. PROVIDE DRYER VENT TO OUTSIDE PER CPC 2022.

Y. GAS VENTS AND NONCOMBUSTIBLE PIPING IN WALLS,PASSING THROUGH THREE FLOORS OR LESS, SHALL BE EFFECTIVELY DRAFT STOPPED AT EACH FLOOR OR CEILING.(CPC 2022).

Z. PROVIDE A SEPARATE VENT FOR EACH WASTE BRANCH LINE EXCEEDING 15 FEET IN LENGTH.

AA. THE MINIMUM AREA OF ANY VENT INSTALLED IN A COMBINATION WASTE AND VENT SYSTEM SHALL BE AT LEAST 2' GROSS SECTIONAL AREA OF THE DRAINPIPE SERVED.

PART­III
E X E C U T I O N

3.01 SCOPE OF WORK:

AB. PROVIDE ALL LABOR, MATERIAL, EQUIPMENT, FACILITIES, TRANSPORTATION, FEES AND SERVICES NECESSARY FOR A COMPLETE PLUMBING SYSTEM(S) AS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. WORKMANSHIP SHALL BE COMPLETE IN EVERY ASPECT, TESTED, APPROVED AND SATISFACTORY TO THE ARCHITECT/ENGINEER AND IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL LAWS HAVING JURISDICTION.

AC. IT IS THE DECLARED AND ACKNOWLEDGED INTENT OF THESE SPECIFICATIONS TO PROVIDE A COMPLETE PLUMBING SYSTEM(S), INCLUSIVE OF ALL REQUIRED PARTS AND ACCESSORIES COMPLETE AND READY FOR USE AS DESCRIBED, BUT NOT LIMITED TO THE FOLLOWING:

AD. DOMESTIC WATER SERVICE AND DISTRIBUTION.
a. DOMESTIC HOT WATER.
b. SANITARY DRAINAGE SYSTEM.
c. PLUMBING FIXTURES.
d. PLUMBING EQUIPMENT.
e. PLUMBING SPECIALTIES.

AE. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT AND LOCATION OF THE WORK INCLUDED. WORK INDICATED, BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED, SHALL BE PROVIDED, INCLUDING THESE DETAILS, WITHOUT EXTRA COST TO THE OWNER.

3.02 DISINFECTION OF POTABLE WATER SYSTEM:

DISINFECT AND FLUSH POTABLE WATER SYSTEM PER LOCAL PLUMBING, BUILDING, AND HEALTH DEPARTMENT REQUIREMENTS.

3.03 FLUSHING:

AF. CHLORINATED WATER SUPPLY: IF WATER SUPPLY SERVING SYSTEM IS CHLORINATED FROM COMMUNITY WATER SYSTEM, SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL NO DIRTY WATER APPEARS AT THE POINT OF OUTLET.

AG. NON-CHLORINATED WATER SUPPLY: WATER SUPPLY SYSTEM SHALL BE FLUSHED WITH CLEAN, POTABLE WATER UNTIL NO DIRTY WATER APPEARS AT THE POINT OF OUTLET.

3.04 LABEL AND IDENTIFICATION:

AH. IDENTIFICATION FOR ALL PIPING SYSTEM(S) SHALL COMPLY WITH ANSI A13.1 FOR SIZE OF LETTERING AND BACKGROUND COLOR FIELD.

AI. PIPING SYSTEM(S): IDENTIFICATION SHALL INCLUDE THE CONTENTS OF THE PIPING SYSTEM(S) AND AN ARROW INDICATING THE DIRECTION OF FLOW.  HAZARDOUS PIPING SYSTEM(S) SHALL ALSO CONTAIN INFORMATION ADDRESSING THE NATURE OF THE HAZARD.  IDENTIFICATION SHALL BE REPEATED AT MAXIMUM INTERVALS OF TWENTY-FIVE (25) FEET AND AT EACH POINT WHERE PIPING PASSES THROUGH A WALL, FLOOR OR ROOF.  COLOR OF THE PIPE IDENTIFICATION SHALL BE DISCERNIBLE AND CONSISTENT THROUGHOUT THE BUILDING.

AJ. EQUIPMENT: IDENTIFICATION SHALL INCLUDE SYSTEM NUMBER, CAPACITY, FLOW, RATE, STATIC PRESSURE, PUMP HEAD, HORSEPOWER, VOLTAGE, ETC.

AK. VALVE TAGS: PROVIDE BRASS VALVE TAGS AND BRASS "S" HOOK FASTENERS WITH VALVE NUMBER AND TYPE OF SERVICE NOTED ON TAG.  PROVIDE DUPLICATE CHARTS, THE CHART SHALL BE FOR ALL VALVES AND SHALL INDICATE VALVE IDENTIFICATION NUMBER, LOCATION AND PURPOSE.

3.05 RECORD DRAWING SUBMITTALS:

AL. AT PROJECT CLOSE-OUT, CONTRACTOR SHALL SUBMIT RECORD DRAWINGS (CERTIFIED OR APPROVED) ALSO KNOWN AS "AS-BUILT" DRAWINGS.  LAYOUT SUBMITTALS SHALL BE SUBMITTED FOR RECORDS PRIOR TO FINAL ACCEPTANCE IN ELECTRONIC FORM ON  COMPACT DISC(S), USING AUTOCAD VERSION 2010 "DWG" FORMAT OR ADOBE ACROBAT "PDF" FORMAT VIEWABLE FROM ADOBE.  RECORD DATA EQUIPMENT, FIXTURE AND  RELATED APPURTENANCES MAY BE SUBMITTED AS BOUND HARDCOPY OR ELECTRONIC ADOBE ACROBAT "PDF" FORMAT.

AM. PROVIDE RECORD SUBMITTALS AS FOLLOWS:

A.A. OWNER: 1 COPY.

A.B. ARCHITECT OF RECORD: 1 COPY.

A.C.ENGINEER OF RECORD: 1 COPY.

CONTRACTOR IS NOT ALLOWED TO USE THE CONTRACT DOCUMENTS FOR "AS-BUILT" DRAWINGS.  BACKGROUNDS SHALL BE IN THE LATEST RELEASE OF AUTOCAD.

1. THE PLUMBING CONTRACTOR SHALL VISIT THE SITE AND
BECOME FAMILIAR WITH THE EXISTING SYSTEMS AND
CONDITIONS IN AREAS OF RENOVATION.

2. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE
OWNER, CM, AND OR GENERAL CONTRACTOR ANY AND ALL
PHASING OF THE PLUMBING DEMOLITION WORK IN ORDER TO
SATISFY THE CONSTRUCTION SCHEDULE. COORDINATE WITH
OWNER REGARDING SHUT DOWN OF ANY BUILDING PLUMBING
UTILITY.

3. ALL SERVICE INTERUPTIONS SHALL BE COORDINATED AND
APPROVED WITH THE OWNER A MINIMUM OF 5 DAYS IN
ADVANCE PRIOR TO COMMENCEMENT OF ANY WORK.

4. THE PLUMBING CONTRACTOR SHALL COORDINATE THEIR
DEMOLITION WORK WITH THAT OF OTHER TRADES IN ORDER TO
AVOID CONFLICTS.

5. THE PLUMBING CONTRACTOR SHALL REMOVE ALL PLUMBING
FIXTURES, CARRIERS, TRIM, ACCESSORIES, EQUIPMENT, FLOOR DRAINS AND PIPING IN AREA OF RENOVATION.

6. ALL PIPING TO BE REMOVED SHALL BE REMOVED
COMPLETELY.ALL PIPE HANGERS, SLEEVES, RISER CLAMPS,
ETC. SHALL BE REMOVED COMPLETELY WITH PIPING. NO
EXISTING HANGER SYSTEMS SHALL BE REUSED FOR NEW
PIPING.

7. NO EQUIPMENT OR DEVICES THAT HAVE BEEN DISCONNECTED
AND OR ABANDONED SHALL REMAIN.

PLUMBING SHEET INDEX PLUMBING DEMOLITION GENERAL NOTES:

SHEET NO. SHEET NAME SCALE
P0.0 PLUMBING GENERAL NOTES AND SYMBOLS N.T.S.

P1.1 ADMINISTRATION BUILDING: PLUMBING 1ST FLOOR DEMOLITION PLAN 3/16" = 1'-0" SR NO.
1 3
4 5
6 ADMINISTRATION BUILDING: PLUMBING 2ND FLOOR DEMOLITION PLAN P1.3 ADMINISTRATION BUILDING: PLUMBING 1ST FLOOR PROPOSED PLAN P1.4 ADMINISTRATION BUILDING: PLUMBING 2ND FLOOR PROPOSED PLAN 3/16" = 1'-0"
3/16" = 1'-0"
3/16" = 1'-0"
7 P2.0 MAINTENANCE BLDG, 311 BLDG & FUEL ISLAND BLDG: PLUMBING DEMOLITION  PLAN PLUMBING DETAILS
8 P4.0
9 P5.0
10 11
2 P1.0 ADMINISTRATION BUILDING: GYM PLUMBING FLOOR PLAN 1/4" = 1'-0" 3/16" = 1'-0"
P2.1 MAINTENANCE BLDG, 311 BLDG & FUEL ISLAND BLDG: PLUMBING PROPOSED PLAN 3/16" = 1'-0" PLUMBING SANITARY RISER DIAGRAMS
PLUMBING SCHEDULES
N.T.S.

N.T.S.

P3.0 N.T.S.

P1.2
P2.2 311 BLDG : PLUMBING ENLARGED PLAN 3/8" = 1'-0"
12 SCOPE OF WORK
13 P3.1 PLUMBING WATER RISER DIAGRAMS N.T.S.

PLUMBING GENERAL NOTES AND SYMBOLS
P0.0
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1421 of 1646 ends

EXERCISE ROOM RESTROOM VESTIBULE

1. DISCONTINUE EXISTING KITCHEN SINK AND DEMOLISHED
ASSOCIATED PIPES, FITTINGS AND VALVES.

2. DEMO EXISTING PLUMBING FIXTURE AND REPLACE WITH NEW
FIXTURE IN PLACE. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION. REFER TO PLUMBING
FIXTURE CONNECTION SCHEDULE ON SHEET P5.0 FOR EXACT PIPE CONNECTION SIZE OF EACH PLUMBING FIXTURE.

3. NEW 4"SANITARY, 2" VENT AND 1 1/2" COLD WATER PIPE
CONNECTION TO THE  EXISTING 4" SANITARY, 3" VENT AND 1 1/2" COLD WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION.

KEYNOTES:

1. ALL DEMOLITION OF THE PLUMBING SYSTEM AS CALLED THE
PLUMBING CONTRACTORS WORK.

2. BEFORE STARTING ANY DEMOLITION ON PLUMBING EQUIPMENT WHICH HAS AN ELECTRICAL CONNECTION, THE PLUMBING
CONTRACTOR SHALL MEET WITH THE ELECTRICAL CONTRACTOR TO IDENTIFY ALL SUCH EQUIPMENT.  THE ELECTRICAL  CONTRACTOR WILL DISCONNECT THE POWER TO EACH UNIT, REMOVE CONDUIT, WIRING, DISCONNECT SWITCHES AND STARTERS UNDER HIS
CONTRACT.  PLUMBING CONTRACTOR SHALL REMOVE ALL PLUMBING EQUIPMENT UNDER THIS CONTRACT.

3. ALL LOCATIONS SHOWN ON THESE DRAWINGS ARE APPROXIMATE.

VERIFY EXACT LOCATIONS IN FIELD.

4. NOT ALL AREAS MAY HAVE BEEN AVAILABLE FOR SURVEY DURING DESIGN. THE CONTRACTOR SHALL THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS IN QUESTION OR THAT COULD NOT BE OBSERVED SHALL BE OUTLINED IN THE CONTRACTORS BID. ADDITIONAL COMPENSATION FOR FAILURE TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS WILL NOT BE APPROVED EXISTING SYSTEMS ARE SHOWN BASED ON VISUAL INSPECTION AND AS-BUILT/DESIGNED
DOCUMENTS, AND MAY NOT REFLECT ACTUAL CONDITIONS.

5. THE DEVICES AND EQUIPMENT INDICATED BY DEMOLITION SYMBOLS ON THE PLANS ARE NOT NECESSARILY THE LIMITS OF THE WORK INVOLVED IN THE RENOVATION. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE COMPLETE SET OF ENGINEER & ARCHITECTURAL PLANS FOR ALL TRADES AND PERFORM A DETAILED FIELD SURVEY DURING THE BIDDING PERIOD TO ENSURE THAT THE ENTIRE SCOPE OF WORK INVOLVED IS INCLUDED IN THE BID PRICE.

6. WHEN UTILITY SYSTEMS NEED TO BE REMOVED,PROVIDE CAP, VALVE, PLUG, OR SEAL TO MEET CODE REQUIREMENTS.

7. REFER TO ARCHITECT PLAN FOR ANY EXISTING TO REMIAN PLUMBING ITEMS.

8. COORDINATE/INFORM WITH OWNER PRIOR TO DEMOLISH AND
REMOVAL OF ANY PLUMBING ITEMS.

PLUMBING DEMOLITION NOTES:
1 2
3 3
3 UR-1
WC-1
L-1
KEYPLAN:

1. ALL PLUMBING WORK TO BE COMPLETED BY A LICENSED PLUMBER PER STATE AND LOCAL.

2. FOR CLARITY,NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE
SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES.

3. REFERS TO FIXTURE & EQUIPMENT DESIGNATION. SEE
CORRESPONDING SPECIFICATION AND EQUIPMENT SCHEDULE FOR
FURTHER INFORMATION.

PLUMBING GENERAL NOTES:

FD-1
DEMOLATION SCOPE AREA
ADMINISTRATION BUILDING:

GYM PLUMBING FLOOR PLAN
P1.0
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT NORTH
SCALE:

GYM- PLUMBING DEMOLITION PLAN 1 1/4" = 1'-0"
SCALE:

PROPOSED GYM RESTROOM 2 1/4" = 1'-0"
UNDER T

Page 1422 of 1646 ends

DISPATCH

VESTIBULE
MEN
WOMEN

VENDING QUIET WOMEN
MEN
CORR.

TRAINING
ROOM

TRAINING
ROOM

STORAGE
CLOSET
ASSIST.

TRANSIT
COORD

CONFERENCE DISPATCH
TRANS.

SUPV.

TRANS.

MGR.

SECRETARY

KITCHEN
PANTRY

RECEPTION
LIFT
DRIVERS LOUNGE
DEMOLATION SCOPE AREA
DEMOLATION SCOPE AREA

1. ALL DEMOLITION OF THE PLUMBING SYSTEM AS CALLED THE
PLUMBING CONTRACTORS WORK.

2. BEFORE STARTING ANY DEMOLITION ON PLUMBING EQUIPMENT WHICH HAS AN ELECTRICAL CONNECTION, THE PLUMBING
CONTRACTOR SHALL MEET WITH THE ELECTRICAL CONTRACTOR TO IDENTIFY ALL SUCH EQUIPMENT.  THE ELECTRICAL  CONTRACTOR WILL DISCONNECT THE POWER TO EACH UNIT, REMOVE CONDUIT, WIRING, DISCONNECT SWITCHES AND STARTERS UNDER HIS
CONTRACT.  PLUMBING CONTRACTOR SHALL REMOVE ALL PLUMBING EQUIPMENT UNDER THIS CONTRACT.

3. ALL LOCATIONS SHOWN ON THESE DRAWINGS ARE APPROXIMATE.

VERIFY EXACT LOCATIONS IN FIELD.

4. NOT ALL AREAS MAY HAVE BEEN AVAILABLE FOR SURVEY DURING DESIGN. THE CONTRACTOR SHALL THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS IN QUESTION OR THAT COULD NOT BE OBSERVED SHALL BE OUTLINED IN THE CONTRACTORS BID. ADDITIONAL COMPENSATION FOR FAILURE TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS WILL NOT BE APPROVED EXISTING SYSTEMS ARE SHOWN BASED ON VISUAL INSPECTION AND AS-BUILT/DESIGNED
DOCUMENTS, AND MAY NOT REFLECT ACTUAL CONDITIONS.

5. THE DEVICES AND EQUIPMENT INDICATED BY DEMOLITION SYMBOLS ON THE PLANS ARE NOT NECESSARILY THE LIMITS OF THE WORK INVOLVED IN THE RENOVATION. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE COMPLETE SET OF ENGINEER & ARCHITECTURAL PLANS FOR ALL TRADES AND PERFORM A DETAILED FIELD SURVEY DURING THE BIDDING PERIOD TO ENSURE THAT THE ENTIRE SCOPE OF WORK INVOLVED IS INCLUDED IN THE BID PRICE.

6. WHEN UTILITY SYSTEMS NEED TO BE REMOVED, PROVIDE CAP, VALVE, PLUG, OR SEAL TO MEET CODE REQUIREMENTS.

7. REFER TO ARCHITECT PLAN FOR ANY EXISTING TO REMAIN PLUMBING ITEMS.

8. COORDINATE/INFORM WITH OWNER PRIOR TO DEMOLISH AND
REMOVAL OF ANY PLUMBING ITEMS.

1. DISCONTINUE EXISTING KITCHEN SINK AND DEMOLISHED
ASSOCIATED PIPES, FITTINGS AND VALVES.

KEYNOTES: PLUMBING DEMOLITION NOTES:
1 (E) 2" VTR
(E) 2" SAN (E) 3/4"CW
(E) 3/4"HW
KEYPLAN:

ADMINISTRATION BUILDING:

PLUMBING 1ST FLOOR DEMOLITION PLAN
P1.1
NORTH
SCALE:

PLUMBING 1ST FLOOR DEMOLITION PLAN 1 3/16" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1423 of 1646 ends

LIFT

WAITING
ADMIN SEC. PLANNING SPECIAL SPECIAL ASSIST. DIR. ACCT. SUPV.

CORR.

CONFERENCE TRANSIT DIR.

LOUNGE ROOF DECK COPY WORK OFFICE
CLERKS
CRC ASLE
ELECT ROOM
MECH. SHAFT

MEN AUDIT
WOMEN
STAIR

ARCHIVES
REMOVE (E) WALL
REMOVE (E) WALL
REMOVE (E) WALL
REMOVE (E) WALL REMOVE (E) WALL
3 2 1

1. ALL DEMOLITION OF THE PLUMBING SYSTEM AS CALLED THE
PLUMBING CONTRACTORS WORK.

2. BEFORE STARTING ANY DEMOLITION ON PLUMBING EQUIPMENT WHICH HAS AN ELECTRICAL CONNECTION, THE PLUMBING
CONTRACTOR SHALL MEET WITH THE ELECTRICAL CONTRACTOR TO IDENTIFY ALL SUCH EQUIPMENT.  THE ELECTRICAL  CONTRACTOR WILL DISCONNECT THE POWER TO EACH UNIT, REMOVE CONDUIT, WIRING, DISCONNECT SWITCHES AND STARTERS UNDER HIS
CONTRACT.  PLUMBING CONTRACTOR SHALL REMOVE ALL PLUMBING EQUIPMENT UNDER THIS CONTRACT.

3. ALL LOCATIONS SHOWN ON THESE DRAWINGS ARE APPROXIMATE.

VERIFY EXACT LOCATIONS IN FIELD.

4. NOT ALL AREAS MAY HAVE BEEN AVAILABLE FOR SURVEY DURING DESIGN. THE CONTRACTOR SHALL THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS IN QUESTION OR THAT COULD NOT BE OBSERVED SHALL BE OUTLINED IN THE CONTRACTORS BID. ADDITIONAL COMPENSATION FOR FAILURE TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS WILL NOT BE APPROVED EXISTING SYSTEMS ARE SHOWN BASED ON VISUAL INSPECTION AND AS-BUILT/DESIGNED
DOCUMENTS, AND MAY NOT REFLECT ACTUAL CONDITIONS.

5. THE DEVICES AND EQUIPMENT INDICATED BY DEMOLITION SYMBOLS ON THE PLANS ARE NOT NECESSARILY THE LIMITS OF THE WORK INVOLVED IN THE RENOVATION. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE COMPLETE SET OF ENGINEER & ARCHITECTURAL PLANS FOR ALL TRADES AND PERFORM A DETAILED FIELD SURVEY DURING THE BIDDING PERIOD TO ENSURE THAT THE ENTIRE SCOPE OF WORK INVOLVED IS INCLUDED IN THE BID PRICE.

6. WHEN UTILITY SYSTEMS NEED TO BE REMOVED, PROVIDE CAP, VALVE, PLUG, OR SEAL TO MEET CODE REQUIREMENTS.

7. REFER TO ARCHITECT PLAN FOR ANY EXISTING TO REMAIN PLUMBING ITEMS.

8. COORDINATE/INFORM WITH OWNER PRIOR TO DEMOLISH AND
REMOVAL OF ANY PLUMBING ITEMS.

1. DISCONTINUE EXISTING SINK AND DEMOLISHED ASSOCIATED
PIPES,FITTINGS AND VALVES.

2. DISCONTINUE EXISTING MOP SINK AND DEMOLISHED
ASSOCIATED PIPES, FITTINGS AND VALVES.

3. DISCONTINUE EXISTING PLUMBING FIXTURE AND DEMOLISHED ASSOCIATED PIPES, FITTINGS AND VALVES.

KEYNOTES: PLUMBING DEMOLITION NOTES:

DEMOLATION SCOPE AREA
(E) 4" VTR
(E) 4" SAN DN
(E) 2"CW DN
(E) 2" VTR
(E) 2" VTR
3/4" CW UP TO ROOF.
(E) 2" VENT DN (E) 2" VTR
AND UP TO ROOF.
3 EXISTING FLOOR
DRAIN TO REMAIN
EXISTING FLOOR
DRAIN TO REMAIN
KEYPLAN:

ADMINISTRATION BUILDING:

PLUMBING 2ND FLOOR DEMOLITION PLAN
P1.2
NORTH
SCALE:

PLUMBING 2ND FLOOR DEMOLITION PLAN 1 3/16" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1424 of 1646 ends

(N)STORAGE Microwave DW
Oven
(E)PRINTER
(N)STORAGE
X
1A5.0 LOUNGE DRIVERS' VESRIBULE DISPATCH

CORRIDOR CORRIDOR CORRIDORTRAINING ROOM TRAINING ROOM KITCHENETTE 1A4.0
2CS-1 DW-1 1

1. ALL PLUMBING WORK TO BE COMPLETED BY A LICENSED PLUMBER PER STATE AND LOCAL.

2. FOR CLARITY,NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE
SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES.

3. REFERS TO FIXTURE & EQUIPMENT DESIGNATION. SEE
CORRESPONDING SPECIFICATION AND EQUIPMENT SCHEDULE FOR
FURTHER INFORMATION.

1. DEMO EXISTING PLUMBING FIXTURE AND REPLACE WITH NEW
FIXTURE IN PLACE. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION. REFER TO PLUMBING
FIXTURE CONNECTION SCHEDULE ON SHEET P5.0 FOR EXACT
PIPE CONNECTION SIZE OF EACH PLUMBING FIXTURE.

PLUMBING GENERAL NOTES:

KEYNOTES:
(E) 2" VTR
(E) 2" SAN
(E) 3/4"CW
(E) 3/4"HW
KEYPLAN:

SCOPE OF WORK
SCOPE OF WORK
ADMINISTRATION BUILDING:

PLUMBING 1ST FLOOR PROPOSED PLAN
P1.3
NORTH
SCALE:

PLUMBING 1ST FLOOR PROPSED PLAN 1 3/16" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1425 of 1646 ends

TV TV TV DECK ROOF CORRIDOR KITCHENETTE LOUNGE CONFERENCE ROOM L-1
WC-1
L-1
L-1 S-1

1. ALL PLUMBING WORK TO BE COMPLETED BY A LICENSED PLUMBER PER STATE AND LOCAL.

2. FOR CLARITY,NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE
SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES.

3. REFERS TO FIXTURE & EQUIPMENT DESIGNATION. SEE
CORRESPONDING SPECIFICATION AND EQUIPMENT SCHEDULE FOR
FURTHER INFORMATION.

1. DEMO EXISTING PLUMBING FIXTURE AND REPLACE WITH NEW
FIXTURE IN PLACE. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION. REFER TO PLUMBING
FIXTURE CONNECTION SCHEDULE ON SHEET P3.0 FOR EXACT
PIPE CONNECTION SIZE OF EACH PLUMBING FIXTURE.

2. NEW 2" SANITARY, 2" VENT, 3/4" HOT AND 3/4" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT, HOT AND COLD WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD VERIFY
PRIOR TO BEGIN CONSTRUCTION.

3. NEW 4"SANITARY, 2" VENT, 3/4" HOT AND 1 1/2" COLD WATER PIPE CONNECTION TO THE  EXISTING 4" SANITARY, 3" VENT, 3/4" HOT AND 2" COLD WATER PIPES. THE CONTRACTOR SHALL NEED TO
FIELD VERIFY PRIOR TO BEGIN CONSTRUCTION.

4. 4" SAN AND 1 1/2" CW PIPE UP TO WC-1.

5. 2" SAN AND 3/4" CW/HW PIPE UP TO L-1.

6. 2" SAN AND 3/4" CW/HW PIPE UP TO S-1.

7. NEW 2" SANITARY PIPE CONNECTION TO THE EXISTING
SANITARY PIPE. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION.

PLUMBING GENERAL NOTES:

KEYNOTES:

UR-1
L-1 L-1
WC-1
WC-1
2 (E) 4" VTR
(E) 4" SAN DN
(E) 2"CW DN
(E) 2" VENT DN
AND UP TO ROOF.

WC-1
L-1
1 1
1 5
5 2
4 4
5 5
WCO
EXISTING FLOOR
DRAIN TO REMAIN
5 2
3 3
2 4"SAN
2"
1 1/2"CW
6 KEYPLAN:

SCOPE OF WORK
S-2
7 6
CO 2"SAN
3/4"HW
2" VENT
3/4"CW
ADMINISTRATION BUILDING:

PLUMBING 2ND FLOOR PROPOSED PLAN
P1.4
NORTH
SCALE:

PLUMBING 2ND FLOOR PROPSED PLAN 1 3/16" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1426 of 1646 ends

1. DISCONTINUE EXISTING PLUMBING FIXTURES
AND DEMOLISHED ASSOCIATED PIPES, FITTINGS
AND PERIOD.

2. DISCONTINUE EXISTING SINK FIXTURES AND
DEMOLISHED ASSOCIATED PIPES, FITTINGS
AND PERIOD.

KEYNOTES:

1. ALL DEMOLITION OF THE PLUMBING SYSTEM AS
CALLED THE PLUMBING CONTRACTORS WORK.

2.BEFORE STARTING ANY DEMOLITION ON PLUMBING
EQUIPMENT WHICH HAS AN ELECTRICAL
CONNECTION, THE PLUMBING CONTRACTOR SHALL
MEET WITH THE ELECTRICAL CONTRACTOR TO
IDENTIFY ALL SUCH EQUIPMENT.  THE ELECTRICAL
CONTRACTOR WILL DISCONNECT THE POWER TO
EACH UNIT, REMOVE CONDUIT, WIRING, DISCONNECT
SWITCHES AND STARTERS UNDER HIS CONTRACT.

PLUMBING CONTRACTOR SHALL REMOVE ALL
PLUMBING EQUIPMENT UNDER THIS CONTRACT.

3.ALL LOCATIONS SHOWN ON THESE DRAWINGS ARE
APPROXIMATE. VERIFY EXACT LOCATIONS IN FIELD.

4.NOT ALL AREAS MAY HAVE BEEN AVAILABLE FOR
SURVEY DURING DESIGN. THE CONTRACTOR SHALL
THOROUGHLY REVIEW ALL AREAS WITHIN THE SCOPE
OF WORK PRIOR TO SUBMITTING HIS BID. ANY AREAS
IN QUESTION OR THAT COULD NOT BE OBSERVED
SHALL BE OUTLINED IN THE CONTRACTORS BID.

ADDITIONAL COMPENSATION FOR FAILURE TO FIELD
VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING
BIDS WILL NOT BE APPROVED EXISTING SYSTEMS ARE
SHOWN BASED ON VISUAL INSPECTION AND
AS-BUILT/DESIGNED DOCUMENTS, AND MAY NOT
REFLECT ACTUAL CONDITIONS.

5.THE DEVICES AND EQUIPMENT INDICATED BY
DEMOLITION SYMBOLS ON THE PLANS ARE NOT
NECESSARILY THE LIMITS OF THE WORK INVOLVED IN
THE RENOVATION. THE CONTRACTOR SHALL
CAREFULLY EXAMINE THE COMPLETE SET OF
ENGINEER & ARCHITECTURAL PLANS FOR ALL TRADES
AND PERFORM A DETAILED FIELD SURVEY DURING
THE BIDDING PERIOD TO ENSURE THAT THE ENTIRE
SCOPE OF WORK INVOLVED IS INCLUDED IN THE BID
PRICE.

6.WHEN UTILITY SYSTEMS NEED TO BE REMOVED,
PROVIDE CAP, VALVE, PLUG, OR SEAL TO MEET CODE
REQUIREMENTS.

7.REFER TO ARCHITECT PLAN FOR ANY EXISTING TO
REMAIN PLUMBING ITEMS.

8.COORDINATE/INFORM WITH OWNER PRIOR TO
DEMOLISH AND REMOVAL OF ANY PLUMBING ITEMS.

PLUMBING DEMOLITION NOTES:

DEMOLATION SCOPE AREA
DEMOLATION SCOPE AREA DEMOLATION SCOPE AREA
DEMOLATION SCOPE AREA
DEMOLATION SCOPE AREA
DEMOLATION SCOPE AREA
DEMOLATION SCOPE AREA
Lobby 1 10 21 OFFICE Copy RM Electrical  RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12    Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor     Conference Room Body Shop 1st Floor Storage     General Staff Office 6   Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's
Restroom
18 Men's
Restroom
17 KEYNPLAN:
1 LOCKER
SHOWER
LOCKER
SHOWER
STAIRS
BREAK ROOM
MEN'S LOCKERS
MEN'S TOILET
WOMEN'S TOILET
TRAINING ROOM
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS
MEN'S TOILET
WOMEN'S TOILET
TOILET
1 1
1 1
1 1
2 MAINTENANCE BLDG, 311 BLDG & FUEL ISLAND BLDG:

PLUMBING DEMOLITION PLAN
P2.0
NORTH
SCALE:

DEMOLITION PLAN - 311 BUILDING 1 3/16" = 1'-0"
NORTH
SCALE:

DEMOLITION PLAN - FUEL ISLAND 3 3/16" = 1'-0"
NORTH
SCALE:

DEMOLITION PLAN - MAINTENANCE BUILDING 1ST FLOOR
2 3/16" = 1'-0"
NORTH
SCALE:

DEMOLITION PLAN - MAINTENANCE BUILDING 2ND FLOOR
4 3/16" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1427 of 1646 ends

STAIRS
BREAK ROOM
TRAINING ROOM
UR-1 WC-1
L-1
L-2
L-2
UR-1
L-1
SH-1
SH-1
FD-1
WC-1
WC-1
FD-1

1. ALL PLUMBING WORK TO BE COMPLETED BY A LICENSED PLUMBER PER STATE AND LOCAL.

2. FOR CLARITY,NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE
SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES.

3. REFERS TO FIXTURE & EQUIPMENT DESIGNATION. SEE
CORRESPONDING SPECIFICATION AND EQUIPMENT SCHEDULE FOR
FURTHER INFORMATION.

1. DEMO EXISTING PLUMBING FIXTURE AND REPLACE WITH NEW
FIXTURE IN PLACE. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION. REFER TO PLUMBING
FIXTURE CONNECTION SCHEDULE ON SHEET P3.0 FOR EXACT
PIPE CONNECTION SIZE OF EACH PLUMBING FIXTURE.

2. NEW 4" SANITARY, 2" VENT, 3/4" HOT AND 1 1/2" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT, HOT AND COLD WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION.

3. NEW 2" SANITARY, AND 2" VENT PIPE CONNECTION TO THE
EXISTING SANITARY AND VENT PIPES. THE CONTRACTOR SHALL
NEED TO FIELD VERIFY PRIOR TO BEGIN CONSTRUCTION.

4. 4" SAN AND 1 1/2" CW PIPE UP TO WC-1.

5. 2" SAN AND 3/4" CW/HW PIPE UP TO L-1.

6. 2" SAN AND 3/4" CW/HW PIPE UP TO SH-1.

7. 2" SAN AND 3/4" CW/HW PIPE UP TO 2CS-1.

8. 2" SAN  PIPE UP TO FD-1.

9. 2" SAN AND 1/2" CW/HW PIPE UP TO S-1.

10. 2" SAN AND 3/4" CW PIPE UP TO UR-1.

11. NEW 4" SANITARY, 2" VENT,  AND 3/4" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT AND COLD
WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD VERIFY
PRIOR TO BEGIN CONSTRUCTION.

12. NEW 2" SANITARY, 2" VENT,  3/4" COLD WATER AND 3/4" HOT WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT,
HOT AND COLD WATER PIPES. THE CONTRACTOR SHALL NEED
TO FIELD VERIFY PRIOR TO BEGIN CONSTRUCTION.

13. NEW 4" SANITARY, 2" VENT, 3/4" HOT AND 1" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT, HOT AND
COLD WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD
VERIFY PRIOR TO BEGIN CONSTRUCTION.

14. NEW 4" SANITARY, 2" VENT,  AND 1 1/2" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT AND COLD
WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD VERIFY
PRIOR TO BEGIN CONSTRUCTION.

PLUMBING GENERAL NOTES:

KEYNOTES:
2CS-1
FD-1
SH-1
FD-1
SH-1
WC-1
Lobby 1 10 21 OFFICE Copy RM Electrical  RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12    Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor     General Staff Office     Conference Room Body Shop 1st Floor Storage 6   Hall Area A Conference RM
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's
Restroom
18 Men's
Restroom
17 1
1 KEYNPLAN:

FD-1
13 2
2 14
S-1
12 12
4 4
4 4
5 5
5 6
6 7
8 8
3 9
P2.1
4 P2.1
1 P2.1
3 P2.1
2 10
11 6 6
SH-1
10 6
8 8
4 5
5 4
10 2
L-1
FD-1
WC-1
WC-1
UR-1
FD-1
L-1
WCO
SCOPE OF WORK  SCOPE OF WORK
SCOPE OF WORK
SCOPE OF WORK
SCOPE OF WORK
SCOPE OF WORK  SCOPE OF WORK
8 P2.1
NORTH
SCALE:

PROPOSED PLAN - FUEL ISLAND BUILDING 2 3/16" = 1'-0"
NORTH
SCALE:

PROPOSED PLAN - MAINTENANCE BUILDING 1ST & 2ND FLOOR
3 3/16" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT MAINTENANCE BLDG,  & FUEL ISLAND BLDG: PLUMBING
PROPSED PLAN
NORTH
SCALE:

PROPOSED PLAN - 311 BUILDING 1 3/16" = 1'-0"
UNDER T

Page 1428 of 1646 ends

1. ALL PLUMBING WORK TO BE COMPLETED BY A LICENSED PLUMBER PER STATE AND LOCAL.

2. FOR CLARITY,NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE
SHUTOFF VALVES IN DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES.

3. REFERS TO FIXTURE & EQUIPMENT DESIGNATION. SEE
CORRESPONDING SPECIFICATION AND EQUIPMENT SCHEDULE FOR
FURTHER INFORMATION.

1. NEW 4" SANITARY, 2" VENT AND 1 1/2" COLD WATER PIPE
CONNECTION TO THE EXISTING SANITARY, VENT AND COLD
WATER PIPES. THE CONTRACTOR SHALL NEED TO FIELD VERIFY
PRIOR TO BEGIN CONSTRUCTION.

2. 3/4" Ø HW PIPE CONNECT TO EXISTING HW PIPE.CONTRACTOR NEED TO FIELD VERIFY THE EXISTING WATER PIPE LOCATION & SIZE PRIOR TO MAKE ANY CONNECTION.

3. 2" SAN AND 3/4" CW PIPE UP TO UR-1.

4. 4" SAN AND 1 1/2" CW PIPE UP TO WC-1.

5. 2" SAN AND 3/4" CW/HW PIPE UP TO L-1.

6. 2" SAN AND 3/4" CW/HW PIPE UP TO SH-1.

7. NEW 4" SANITARY, 2" VENT, 3/4" HOT WATER AND 1 1/2" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT,
HOT WATER AND COLD WATER PIPES. THE CONTRACTOR SHALL
NEED TO FIELD VERIFY PRIOR TO BEGIN CONSTRUCTION.

8. NEW 4" SANITARY, 2" VENT, 3/4" HOT WATER AND 3/4" COLD WATER PIPE CONNECTION TO THE EXISTING SANITARY, VENT,
HOT WATER AND COLD WATER PIPES. THE CONTRACTOR SHALL
NEED TO FIELD VERIFY PRIOR TO BEGIN CONSTRUCTION.

PLUMBING GENERAL NOTES:

KEYNOTES:

Lobby 1 10 21 OFFICE Copy RM Electrical  RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12    Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor     Conference Room Body Shop 1st Floor Storage     General Staff Office 6   Hall Area A Conference RM
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's
Restroom
18 Men's
Restroom
17 Unisex
Unisex
Restroom 1
Restroom 2
Women's
Restroom
Men's
Restroom
UNISEX RESTROOM 1
L-1
WC-1
FD-1
UR-1
1 5
4 3
2 WOMEN'S RESTROOM 1 MEN'S RESTROOM 1
SH-1
WC-1
WC-1
L-1
WC-1
SH-1 UR-1
WC-1
7 7
8 7
1 4
4 4
4 5
5 6
6 L-1
SH-1
6 SH-1
3 UNISEX RESTROOM 2
WC-1
L-1 1
4 5
2 P2.2
SCALE:

PROPOSED ENLARGED PLAN - 311 BUILDING 1 3/8" = 1'-0"
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT 311 BLDG : PLUMBING ENLARGED PLAN
SCALE:

PROPOSED KEY PLAN - 311 BUILDING 2 3/8" = 1'-0"
UNDER T

Page 1429 of 1646 ends

BASEMENT
4"Ø SANITARY PIPE CONNECT TO
EXISTINTG SANITARY
PIPE.CONTRACTOR NEED TO
VERIFY THE EXISTING
SANITARY  PIPE LOCATION,
SIZE AND CONDITION PRIOR
TO CONNECT IT.
4"
L-1
WC-1 4"
UR-1 3" 2"
FD-1
4"
FIRST FLOOR
L-2
4"
DF-2
2CS-1 SS-3
FD-1 FD-1 WC-2 WC-2
L-2 L-1 U-2 L-1 S-1 L-1 L-1
S-1

WCO WCO
SECOND FLOOR
L-1 L-1
U-2
WC-1 WC-1
U-2
FD-1 FD-1
U-1
FD-1 FD-1 WC-2 WC-2 SH-1 SH-1
L-1 L-1
L-1 L-1 DF-1
4"
4"
4" 4" 4"
1 1/4"VTR 1 1/2"VTR 3"VTR 2"VTR 2"VTR 2"VTR 2"VTR 1 1/4"VTR 2"VTR 3" 2"
2" 2 1/2" 2 "
2"
2"
WC-1 WC-1
ROOF
L-1 L-1
WC-1 WC-1
95 DFU 84 DFU 79 DFU
10 DFU
14 DFU 63 DFU 55 DFU 2 DFU
27 DFU
PLUMBING SANITARY RISER DIAGRAMS
P3.0
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT SCALE:

PLUMBING SANITARY DRAINAGE  RISER DIAGRAMS 1 1/4" = 1'-0" UNDER T

Page 1430 of 1646 ends

SECOND FLOOR

FIRST FLOOR
HB-1 HB-1 HB-1
HB-1
WS-1 HB-1 HB-1 HB-1
HB-1
S-3
L-4 U-1 WC-2
L-1
HB-1
HB-1 HB-1 HB-1 HB-1 HB-1 HB-1
HB-1 HB-1 HB-1 HB-1 HB-1 HB-1
L-2 U-1 WC-1
BFP
ROOF

BASEMENT
DF-1 L-1
L-1 L-1
WC-1 WC-1
U-1
L-1
WC-1 WC-1
L-1 L-1 L-1
WC-1 U-2 U-1 WC-1 WC-2 WC-2 SH-1 SH-1
TRAP PRIMER
W/ ACCESS (TYP)
L-1 L-2 S-1
S-1
HB-1
HB-1
WC-2
WC-2
U-1 U-2 L-1 L-1
SS-1
TRAP PRIMER
W/ ACCESS (TYP)
L-1
DF-2 WH-1 S-1

SECOND FLOOR

FIRST FLOOR
ROOF

BASEMENT
WH-1
2CS-1
L-1
L-2
L-2
L-1 S-1
L-1 L-1
SH-1 SH-1 L-2 L-1 SS-1 S-2
S-1
L-1
L-1 L-1 L-1
L-2
2CS-1
2"(50) 4"(671)
3/4"(1.5)
3/4"
3/4" 3/4"
1"(5)
1"(8.5)
1"(11.5) 1"(13)
1 1/4"(16) 1 1/4"(17.5)
1 1/2"(27)
1 1/4"(21)
4"(582)
1 1/4"(15)
3/4"(1.5)
1 1/2"(20)
1" 1"
1" 1"
1"
1"
3" 3" 3"(552) 2" 2"(19)
3/4"
4"(606) 4"(611)
1"(10) 2"(40)
3/4"
3"(162)
2"(46) 2"(8)
2"(38)
1 1/2" 3/4"(4)
2"(52.5)
2 1/2"(139) 2"(55)
2 1/2"(84)
2 1/2"(59)
2"(25)
2 1/2" 3/4"
2 1/2"(141)
3"(145)
4"(833)
4"
PLUMBING WATER RISER DIAGRAMS
P3.1
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT SCALE:

COLD WATER RISER DIAGRAM 2 N.T.S.

SCALE:

HOT WATER RISER DIAGRAM 1 N.T.S.

UNDER T

Page 1431 of 1646 ends

PIPE HANGER SUPPORT DETAIL
NOT TO SCALE

CONCRETE
SLAB
DROP-IN ANCHOR
HILTI HDI OR EQUAL
HANGER
ROD
CLEVIS HANGER W"X1R"
CARBON STEEL
COPPER PLATED
1 UNISTRUT P-1100 PIPE CLAMP,
USE FOR PIPING (TYP).

NUMBER OF HANGER RODS SHALL BE
REQUIRED FOR PROPER SUPPORT (MIN OF 2
MIN) ONLUY ONE IS SHOWN FOR CLEARITY.

UNISRTUT SUPPORT NUT (TYP).
20 GA. GALV. 12" LONG METAL SHIELDS
SHALL BE USED AROUND INSULATION
AT ALL SUPPORT LOCATION (TYP).

INSULATION (TYP).

PIPE (TYP.)
CONDUIT (TYP).

UNISTRUIT UNI-CLIP CLAMP
USE FOR ELEC. CONDUIT.

UNISTRUIT1-5/8" X 1-5/8"
CHANNEL SUPPORT (TYP).

NOTES:

1. 1. ALL PIPE, CONDUIT, ETC. OF ALL TRADES SHALL BE COMBINED OF SAME SUPPORT CHANNEL WHERE PRACTICAL.

2. SUPPORT CHANNEL LENGTH SHALL NOT BE DETERMINED UNTIL ALL PIPING, CONDUIT, ETC. TO BE SUPPORTED IS COORDINATED.

3. SUPPORT CHANNEL SPACING SHALL BE NO MORE THAN 10'-0" NOT TO SCALE
2 PIPE SUPPORT DETAIL
PLUMBING DETAILS
P4.0
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1432 of 1646 ends

SFSH KOHLER - SINGLE FUNCTUION
SHOWER HEAD WALL SEEREMARKS
- HYDRORAIL-S 1.75 GPM
ADA COMPLIANT
3/4" 3/4"
TWO

COMPARTMENT
SINK
-
STAINLESS STEEL ,HEAVY-DUTY STAINLESS STEEL
DURABLE, RUST RESISTANCE, AND EASY CLEANING.
1/2" 1/2" - - Model:

QRSSCTXPS
CY330MR4VO
2CS-1 VEVOR

NEOMETRO
System M-1
Model 8981
STAINLESS STEEL
PER PLAN
L-2 - - - 2" 2" MULTIPLE

LAVATORY
PLUMBING FIXTURE SCHEDULE : ADMIN BUILDING
SYMBOL MANUFACTURER MODEL FIXTURE MOUNTING HW CW WASTE VENT ACCESSORIES / REMARKS WCO ZURN Z1447 WALL CLEAN OUT WALL SEE

REMARKS
- MATCH CONNECTED PIPE SIZE UP TO 4".

SECONDARY CLOSURE PLUG. - -
WC-1 AMERICAN

STANDARD
Model:
3043.528.020 WATER CLOSET - 3/4" 4" 2"
FLUSH TECHNOLOGY: HET HIGH EFFICIENCY
ADA COMPLIANT
CA DROUGHT COMPLIANT
APPROVED FOR COMMERCIAL USE”
-
PIPE

HANGERS
B-LINE OR
EQUAL
200F PIPE HANGERS - -
FC-1 BOBRICK Model:

B-8879,B-8878 FAUCET 3/4" 3/4"
FINISH : POLISHED NICKEL
MATERIAL : DIECAST ZINC
MOUNTING TYPE : COUNTER MOUNTED
OPERATION : AUTOMATIC
- - - -
WC-2 AMERICAN

STANDARD
Model:
3351576.020
- 3/4" 2" 2"
FLUSH TECHNOLOGY: HET HIGH EFFICIENCY
ADA COMPLIANT
CA DROUGHT COMPLIANT
APPROVED FOR COMMERCIAL USE
WATER SENSE CERTIFIED
-

NEOMETRO
System M-1
Model 8981

LAVATORY
STAINLESS STEEL,24”L X21-1/2” W X
17” H
L-1 - - 2" 2"
URINAL - FLUSH TECHNOLOGY: HET HIGH EFFICIENCY
ADA COMPLIANT
ANSI CERTIFICATION
APPROVED FOR COMMERCIAL USE
CA DROUGHT COMPLIANT
1/2" 1/2" - - Model:
6002.001-B4.020
-
WATER CLOSET
UR-1

AMERICAN

STANDARD
- - -
S-1 CORIAN  ACCESSIBLE-5610 SINK

KITCHEN
FLOOR
SEE

REMARKS
- CORIAN / BONEMADE FROM AN ACRYLIC-POLYESTER SOLID SURFACE ADA COMPLIANT WHEN INSTALLED ACCORDING TO GUIDELINES
3/4" 3/4"
KF-1 KOHLER K-28269 KITCHEN FAUCET KITCHEN
FLOOR
SEE

REMARKS
- COVERED UNDER KOHLER'S LIMITED LIFETIME WARRANTY
FAUCET BODY CONSTRUCTED OF METAL
SINGLE HOLE MOUNTING TYPE
DECK MOUNTED FAUCET INSTALLS DIRECTLY TO SINK OR
INCLUDES CERAMIC DISC CARTRIDGE
COMPLIES WITH ADA STANDARDS
3/4" 3/4"
ONE

COMPARTMENT
SINK
-
STAINLESS STEEL ,HEAVY-DUTY STAINLESS STEEL
DURABLE, RUST RESISTANCE, AND EASY CLEANING.
1/2" 1/2" - - Model:

T302209RS1
1CS-1 VEVOR
PLUMBING SCHEDULES
P5.0
UNDER THE SUPERVISION OF: Sheet Number:

DESIGNED BY:

DRAWN BY:

CHECKED BY: DATE:

ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT

SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT

LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.

UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.

REVISIONS
311 S Greenwood Ave. , Montebello , CA 90640
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT UNDER T

Page 1433 of 1646 ends

PREPARED FOR
Cesar Lopez
City of Montebello
3238871363
[email protected]
11/03/2025
City of Montebello Busline
Modernization
Project Number P-0105476
KYA CivicBuys 3570
Contact
Armando Ortega
1800 E. McFadden Ave.

Santa Ana, CA
[email protected]
Pages 8 LICENCE 984827 (B, C15, D12, A, C20, C10, C33)
DIR #1000003379

ATTACHMENT B

Page 1434 of 1646 ends

Proposal: P-0105476 Date: 11/03/2025
To: City of Montebello
1600 West Beverly Boulevard
Montebello CA 90640
Terms: Net30
RA: Armando Ortega
RA Phone:

RA Email: [email protected]
Site:

Address: 400 S Taylor Ave
Montebello CA, 90640
Site Qualifications and General Scope of Work
Priced per KYA CivicBuys 3570
Notes: Sales tax rate will be based upon the shipping address. Price is good for 30 days from date of quote.

Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 2

Page 1435 of 1646 ends

SCOPE OF WORK - PRICING
City of Montebello Busline Modernization Quantity U/M Price Value Taxable Removal of Existing Surface 30714 SF $2.67 $82,006.38
RMIXCON - READY MIX CONCRETE 20 CY $217.61 $4,352.20 T
CONPUM - CONCRETE PUMP 20 EA $409.06 $8,181.20
CUUBEX - CUUBE X SERIES 210 SF $1,532.72 $321,871.20 T
UPCAB - UPPER CABINET W/ FULL HEIGHT DOOR 157 LF $377.37 $59,247.09 T BSCAB - BASE CABINET W/ FULL HEIGHT DOORS 304 LF $385.47 $117,182.88 T CUSCT - CUSTOM COUNTERTOP 608 SF $43.82 $26,642.56 T
DW34 - DRYWALL SHEET - 3/4" 8276 SF $22.43 $185,630.68 T R15INS - R-15 WALL INSULATION 8276 SF $2.83 $23,421.08 T WOODDOOR - PRE-FINISHED WOOD DOOR OPTION 19 EA $1,306.56 $24,824.64 T 2PDSLD - DOUBLE POD BOOTH- 2 SLIDER DOOR 1 EA $14,151.08 $14,151.08 T 2PDSWNG - DOUBLE POD BOOTH- DOUBLE SWING DOOR 1 EA $16,100.79 $16,100.79 T DM50 - DISTRACTION MARKER 560 EA $62.73 $35,128.80 T
ALUFRM - ADJUSTABLE ALUMINUM FRAME OPTION 19 EA $466.63 $8,865.97 T STRFRNTWIN - STORE-FRONT WINDOW SYSTEM 507 SF $203.33 $103,088.31 T MTLSTD - METAL STUD FRAME 10694 LF $22.63 $242,005.22 T CTTBR - CEILING T BAR GRID SYSTEM 8111 SF $9.91 $80,380.01 T CTX - CEILING TILE X 8111 SF $3.92 $31,795.12 T
WDSTD - WOOD STUD FRAME 32640 LF $7.54 $246,105.60 T
ELE-FP-100 - FLOOR ANCHOR ? FLOATING WOOD FLOOR
ANCHO
102 EA $234.95 $23,964.90
UPGRADE - UPGRADE WITH DESIGN WORK 25006 SF $4.56 $114,027.36 ELE-CC3 - COMMERCIAL COATING SERVICE #2 (75,000 SQ 2 EA $359,975.16 $719,950.32 T WMTLT - WALL MOUNTED TOILET 19 EA $358.73 $6,815.87 T
URINAL - URINAL 7 EA $368.65 $2,580.55 T
GRAB36 - 36" RESTROOM GRAB BAR 12 EA $71.45 $857.40 T
GRAB48 - 48" RESTROOM GRAB BAR 12 EA $77.47 $929.64 T
FEMREC - FEMININE HYGIENE RECEPTACLES 9 EA $35.71 $321.39 T HNDDRY - AUTOMATIC HAND DRYER 12 EA $1,071.22 $12,854.64 T WMSNK - WALL MOUNTED PORCELAIN SINK 16 EA $111.31 $1,780.96 T TPDISP - TOILET PAPER DISPENSER 17 EA $53.56 $910.52 T
RRPRT - RESTROOM PARTITION SYSTEM 84 LF $403.44 $33,888.96 T Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 3

Page 1436 of 1646 ends

City of Montebello Busline Modernization Quantity U/M Price Value Taxable AWMSOAP - WALL MOUNTED SOAP DISPENSERAUTOMATIC16 EA $55.64 $890.24 T APTWLR0 - INDUSTRIAL PAPER TOWEL DISPENSERROLLS12 EA $115.54 $1,386.48 T Q2R1218723A - QS PKG LOCKER 2T 3W 12X18X72

ASSEMBLED
172 EA $1,692.85 $291,170.20 T
LBS09096P - 9.5" X 96" HARWOOD LOCKER BENCH AND
PEDE
22 EA $567.29 $12,480.38 T
3CSINK - THREE COMPARTMENT SINK 3 EA $1,838.72 $5,516.16 T SWNGDR - SWING DOOR- DIVIDER SYSTEM 13 EA $5,000.06 $65,000.78 T 072220MIW - TYPE LL. MAGNETIC IDEATION WALL 12 EA $56.47 $677.64 T ELM2AC001 - ELEMENTSAIRE 2-TON COMFORT SYSTEM
(PACKA
1 EA $10,133.78 $10,133.78 T
70902 - WALL-GARD/FLOOR GARD HD, SATIN 650 EA $132.99 $86,443.50 T NUMBTILE - NURAZZO- MARBLE TILE 6000 EA $18.53 $111,180.00 T MNS-4000UL/24 - MNS 4000 LED DISPLAY, 24V, UL1638 10 EA $6,892.94 $68,929.40 T EWLGHT - ELECTRICAL WIRING - LIGHTING 25006 LF $38.22 $955,729.32 T 2X4LED - 2X4 LED LIGHT KIT 158 EA $157.53 $24,889.74 T
4CANLED - 4" CAN LED LIGHT KIT 117 EA $47.14 $5,515.38 T ELC-G1212 - LIGHTING CONTROLLER (12 GE RELAY

OPS,MS/
40 EA $872.94 $34,917.60 T
07000560 - PVC PIPE SCHEDULE 80 142 LF $6.27 $890.34 T
CWTR2 - COPPER WATER LINE UP TO 2" OD 426 LF $45.28 $19,289.28 T CEILREG - CEILING REGISTER 142 EA $119.46 $16,963.32 T
CPTTILECUS - CARPET TILE- CUSHION BACK 132 SY $44.97 $5,936.04 T 604734021-1 - C-12E PRESSURE SENSITIVE ADHESIVE--
FLEX20 EA $93.03 $1,860.60 T
N516470 - ID LATITUDE - WOOD 4608 SF $4.23 $19,491.84 T 959 HM VINYL TILE & PLANK ADHESIVE 25 EA $219.23 $5,480.75 T CB45 - 4.5" COVE BASE 1300 LF $1.66 $2,158.00 T
CVADH -COVE BASE ADHESIVE 32 EA $62.23 $1,991.36 T
SUNDRIES - SUNDRIES 30 EA $735.38 $22,061.40 T
Dumpster Service 35 EA $906.40 $31,724.00
Specialty Equipment Service 20 EA $2,269.10 $45,382.00
Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 4

Page 1437 of 1646 ends

City of Montebello Busline Modernization Quantity U/M Price Value Taxable PWSUPPORTAEADD - Professional Services (Hourly Rate) 30 EA $3,639.29 $109,178.70 Floor Covering Journeyman (So Cal) 158 HRS $115.10 $18,185.80 General Laborer Material Handler Level 1 4335 HRS $105.37 $456,778.95 General Laborer Journeyman 25238 HRS $152.20 $3,841,223.60 Construction Project Supervisor 7763 HRS $181.53 $1,409,217.39 Bonding Fee 1 EA $57,446.70 $57,446.70
Total Before Sales Tax $10,289,983.99
Sales Tax $429,730.04
Total Price $10,719,714.03
Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 5

Page 1438 of 1646 ends

CONDITIONS AND WARRANTY
1) Proposal:

The above proposal is valid for 30 days from the date first set forth above. After 30 days, we reserve the right to increase prices due to the rise in cost of raw materials, fuel or other cost increases. When applicable, KYA Services, LLC reserves the right to implement a surcharge for significant increases in raw materials, including, but not limited to; fuel, and materials. Due to the duration of time between proposals, contracts and final furnishing, KYA Services, LLC reserves the right to implement this surcharge when applicable. Any job that is accepted prior to December 31st of the current year and scheduled to install after December 31st of the current year is subject to price increase. All project proposals based on a specific set/sets of plans are considered preliminary budgets and may be subject to pricing changes once the plans are approved by the relevant authority 2) Purchase:

By executing this proposal, or submitting a purchase order pursuant to this proposal (which shall incorporate the terms of this agreement specifically by reference) which is accepted by KYA Services, LLC . (the “Company”), the purchaser identified above (“you” or the “Purchaser”) agrees to purchase the materials and the services to be provided by the “Company”, as detailed in the Pricing and “General Scope of Work” sections in this agreement, above.

Any additional costs arising from tariff changes shall be deemed pass-through costs and shall be paid by the Client upon receipt of supporting documentation from the Contractor.
3) Standard Exclusions:

Unless specifically included, this agreement does not include, and Company will not provide services, labor or materials for any of the following work: (a) removal or disposal of any material containing asbestos or any hazardous materials as defined by the EPA; neither we nor our installers are responsible for the handling, removal or abatement of asbestos contained floor material or adhesive. Further, our policy is to request an Asbestos Hazard Emergency Response Act (AHERA) report prior to proceeding with any floor material or floor adhesive removal. We and our installers consider it the owners responsibility to produce this report prior to executing this contract. (b) moving Owner’s property around the installation site. (c) repair or replacement of any Purchaser or Owner- supplied materials. (d) repair of concealed underground utilities not located on prints, supplied to Company by Owner during the bidding process, or physically staked out of by the Owner, and which are damaged during construction; or (e) repair of damage to existing surfaces that could occur when construction equipment and vehicles are being used in the normal course of construction. 4) Insurance Requirements:

Company is not required to provide any insurance coverage in excess of Company’s standard insurance. A copy of the Company’s standard insurance is available for your review prior to acceptance of the Company’s proposal. 5) Payment;
Terms of payment are defined in the “Pricing” details section and are specific to this contract. For purposes of this agreement, “Completion” is defined as being the point at which the materials have been furnished. In any event where Completion cannot be effected due to delays or postponements caused by the Purchaser or Owner, final payment (less 5% retainage) is due within 30 days of the date when the Completion was scheduled, had the delay not occurred. All payments must be made to KYA Services, LLC 1800 E. McFadden Ave., Santa Ana, CA 92705 . If the Purchaser or Owner fails or delays in making any scheduled milestone payments , the Company may suspend the fulfilment of its obligations hereunder until such payments are made, or Company may be relieved of its obligations hereunder if payment is more than 60 days past due. Company may use all remedies available to it under current laws, including but not limited to filing of liens against the property and using a collection agency or the courts to secure the collection of the outstanding debt.
6) Lien Releases:

Upon request by Owner, Company will issue appropriate partial lien releases as corresponding payments are received from Purchaser, but prior to receiving final payment from Purchaser or Owner, Company will provide a full release of liens upon receipt of final payment. In accordance with state laws, Company reserves the right to place a lien on the property if final payment has not been received 10 days prior to the filing deadline for liens. 7) Site Plan Approval, Permit/s, Permit Fees, Plans, Engineering Drawings and Surveying:

Site plan approval, permits, permit fees, plans, engineering drawings and surveying are specifically excluded from this agreement and the Services unless specified under the “General Scope of Work”. The Company does not in any way warrant or represent that a permit or site plan approval for construction will be obtained. Sealed engineered drawings that are required but not included in the “General Scope of Work” will result in additional cost to Purchaser.
8) Manufacturing and Delivery:

Manufacturing lead-time and delivery varies depending on the product purchased. 9) Returned Product, Deposits and/ or Cancelled Order:

From date of shipment from our facility, all returned product(s) and cancelled orders are subject to a 50% restocking fee. No returns are available following this date. All deposits are non-refundable.

Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 6

Page 1439 of 1646 ends

10) Concealed Conditions:
“Concealed conditions” include, without limitation to, water, gas, sprinkler, electrical and sewage lines, post tension cables, and steel rebar. Observations that were able to be made either by visual inspection or by drawings and/or plans submitted by Owner at the time this agreement was approved. If additional Concealed Conditions are discovered once work has commenced which were not visible at the time this proposal was approved, Company will stop work and indicate these unforeseen Concealed Conditions to Purchaser or Owner so that Purchaser and Company can execute a change order for any additional work. In any event, any damage caused by or to unforeseen Concealed Conditions is the sole responsibility of the Purchaser and Company shall not be held liable for any such damage. Soil conditions are assumed to be soil that does not contain any water, hard rock (such as limestone, caliche, etc.), rocks bigger than 4inches in diameter or any other condition that will require additional labor, equipment and/or materials not specified by the purchaser or Owner in the bidding process. Any condition requiring additional labor, equipment, and/or materials to complete the drilling or concrete operations will require a change order before Company will complete the process. Any variation will incur additional charges. 11) Changes in the Work:

During the course of this project, Purchaser may order changes in the work (both additions and deletions). The cost of these changes will be determined by the Company, and a change order must be completed and signed by both the Purchaser and the Company, which will detail the “General Scope of the Change Order”. Should any change be essential to the completion of the project, and the Purchaser refuses to authorize such change order, then Company will be deemed to have performed its part of the project, and the project and Services will be terminated. Upon such termination, Company will submit a final billing to Purchaser for payment, less labor allowance for work not performed but including additional charges incurred due to the stoppage.

No credit will be allowed for materials sold and supplied, which will remain the property of the Purchaser. 12) Warranty; Limitations of Liability:

Company warrants that all Company-supplied labor and Services will be performed in a good and workmanlike manner. Purchaser shall notify the Company in writing detailing any defects in Service for which a warranty claim is being made. COMPANY SHALL NOT IN ANY EVENT BE LIABLE FOR

INDIRECT, SPECIAL, CONSEQUENTIAL, INCIDENTAL, PUNITIVE OR LIQUIDATED DAMAGES IN ANY ACTION ARISING FROM OR RELATED TO

THIS AGREEMENT, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), INTENDED CONDUCT OR OTHERWISE, INCLUDING

WITHOUT LIMITATION, DAMAGES RELATING TO LOSS OF PROFITS, INCOME OR GOODWILL, REGARDLESS OF WHETHER COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT WILL COMPANY’S LIABILITY FOR MONETARY DAMAGES UNDER

THIS AGREEMENT EXCEED THE FEES PAID OR DUE AND PAYABLE FOR THE SERVICE UNDER THIS AGREEMENT (OR RELEVANT PURCHASE ORDER). The warranties or the materials are contained in a separate document between Company and the ultimate Owner of the materials, which will be provided to Owner at the time of completion of work.
13) Indemnification:

To the fullest extent permitted by law. Purchaser shall indemnify, defend and hold harmless the Company and its consultants, agents and employees or any of them from and against claims, damages, losses and expenses, including but not limited to attorney’s fees, relating to furnishing of the materials or performance of the Services, provided that such claim, damage, loss or expense is attributable to bodily injury to, sickness, disease or death of a person, or injury to or destruction of tangible property, but only to the extent caused by the negligent acts or omissions of the Purchaser or its agents, employees, or subcontractors or anyone directly or indirectly employed by them or anyone for whose acts they may be liable, regardless of whether or not such claim, damage, loss or expense is caused in part by a party indemnified hereunder. Such obligation shall not be construed to negate, abridge or reduce other rights or obligations of indemnity that would otherwise exist as to a party or person described in Section 13. 14) Delegation: Subcontractors:

The Services and furnishing of materials may be performed by subcontractors under appropriate agreements with the Company 15) Force Majeure: Impracticability:

The Company shall not be charged with any loss or damage for failure or delay in delivering or furnishing of materials when such failure or delay is due to any cause beyond the control of the Company, due to compliance with governmental regulations, or orders, or due to any acts of God, lockouts, slowdowns, wars or shortages in transportation, materials or labor. 16) Dispute Resolution:

Any controversy or claim arising out of or related to this agreement must be settled by binding arbitration administered in CA, 92705 by a single arbitrator selected by the parties or by the American Arbitration Association, and conducted in accordance with the construction industry arbitration rules.

Judgement upon the award may be entered in any court having jurisdiction thereof. 17) Entire Agreement; No Reliance:

This agreement represents and contains the entire agreement between the parties. Prior discussion or verbal representations by the parties that are not contained in this agreement are not part of this agreement. Purchaser hereby acknowledges that it has not received or relied upon any statements or representations by Company or its agents which are not expressly stipulated herein, including without limitation any statements as to the materials, warranties or services provided hereunder.

Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 7

Page 1440 of 1646 ends

18) No Third-Party Beneficiaries:

This agreements creates no third party rights or obligations between Company and any other person, including any Owner who is not also a Purchaser. It is understood and agreed that the parties do not intend that any third party should be a beneficiary of this agreement. 19) Governing Law:

This agreement will be constructed and enforced in accordance with the laws of the State of California. 20) Assignment:

Purchaser may not assign this agreement, by operation of law or otherwise, without the prior written consent of the Company. The agreements shall be binding upon and ensure to the benefit of the Company and the Purchaser, and their successors and permitted assigns.

Executed to be effective as of the
date executed by the company: KYA Services, LLC
Accepted by:

Signature: Signature:

By: (Print) By: (Print)
Title: Title:

Date: Date:

Intials
This is a legal agreement - please read carefully
Complete and Intial all pages Proposal Number P-0105476 8

Page 1441 of 1646 ends

Procurement Division
707 Third Street, 2nd Floor, MS #2-202
West Sacramento, CA 95605-2811
State of California

MULTIPLE AWARD SCHEDULE

NON-MANDATORY
KYA Services, LLC Categories Information
CMAS NUMBER: 4-20-78-0089C
SUPPLEMENT NUMBER: 7
CMAS TERM DATES: 02/26/2020 through 02/10/2030
EFFECTIVE DATE: 01/21/2025
CMAS CATEGORY: Non-IT Commodities General Provisions

APPLICABLE STATE OF

CALIFORNIA GENERAL
PROVISIONS:

June 21, 2022

APPLICABLE CMAS SPECIAL
PROVISIONS: January 2, 2025
MAXIMUM ORDER LIMIT:

State Agencies: See Purchasing Authority
Dollar Threshold provision
Local Government Agencies: Unlimited
FOR USE BY: State & Local Government Agencies
BASE SCHEDULE #: 47QSMA20D08P7
BASE SCHEDULE HOLDER: KYA Services LLC
PROGRAM ANALYST Trice Baker
[email protected]
This California Multiple Award Schedule (CMAS) provides for the purchase, warranty, removal, disposal, preparation, installation, maintenance, and repair of park and playground equipment, commercial flooring, roofing products, preengineered and prefabricated buildings and structures for storage solutions, hardware store products, lawn and garden equipment, heating, ventilation, and air conditioning (HVAC), energy-efficient lighting, power distribution equipment, complete daycare, preschool and classroom solutions, signs, and flags. (See pages 4 through 10 for the services, job titles, and restrictions applicable to this CMAS.)

ATTACHMENT C

Page 1442 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 2 This supplement is to extend this CMAS through 02/10/2030. In addition, this supplement replaces the existing CMAS. The most current Ordering Instructions, General Provisions, CMAS Special Provisions, and products and/or services are included herein. All purchase orders issued by State agencies shall incorporate these Ordering Instructions, General Provisions, and CMAS Special Provisions. Review these provisions carefully as they have changed.

NOTICE: Products and/or services on this CMAS may be available on a Mandatory State Contract.

If this is the case, the use of this CMAS is restricted unless the State agency has an approved exemption as explained in the State Contract User Instructions. Information regarding State Contracts can be obtained at the: State Contracts Index Listing. This requirement is not applicable to local government agencies.

Any reference to a specific manufacturer’s or publisher’s warranty or terms and conditions as shown in the base schedule are not applicable to this CMAS.

The services provided under this CMAS are only available in support of the products covered by this CMAS.

State agencies cannot use this CMAS to purchase products available through the California Prison Industry Authority (CALPIA) without a one-time exemption from CALPIA. Agencies may request an exemption at the CALPIA website. A copy of the approved exemption must be kept with the purchase order in the procurement file for audit purposes.

CMAS RESTRICTION FOR CARPET PURCHASES
The Department of General Services’ Office of Sustainability has determined that all carpet purchased by state agencies be made at the ANSI/NSF-140 Platinum level. The Governor’s Executive Order B-18-12 Ordered that the State agencies purchase and use environmentally preferable products that have a lesser or reduced effect on human health and the environment.

Carpet that is 3rd party certified to ANSI/NSF-140 Platinum level meets the requirement.

IMPORTANT NOTE TO ALL USERS OF THIS MULTIPLE AWARD SCHEDULE A contract for the purchase and installation of carpet is a public works contract as defined in Section 1101 of the Public Contract Code and, as such, requires certain special conditions. Prior to placing an order against this multiple award schedule, read pages 27 through 36 entitled “Information Regarding the Purchase and Installation of Carpet and Other Floor Coverings” to ensure your agency understands the special conditions involving public works contracts. If your agency does not have staff with expertise involving public works contracts, it is recommended that you seek interagency assistance or consider not using this multiple award schedule.

Page 1443 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 3

HAZARDOUS SUBSTANCES
State Law (Labor Code (LC) 6360 et seq.) requires employers to have information regarding hazardous or potentially hazardous substances in the workplace on file or readily available to them. In order to assist employers’ compliance with this requirement, the Department of Industrial Relations has compiled a list of hazardous substances.

Some or all of the products listed on this CMAS appear on the Hazardous Substances List. CMAS supplier must provide Material Safety Data Sheet for these products when they are delivered to California Public Agencies. A Material Safety Data Sheet is supplied by the manufacturer of a substance and lists the manufacturer’s name and address, the chemical name, physical properties of the material, potential hazards, safeguards and procedures to follow in case of accident or overexposure.

Agency non-compliance with the requirements may result in the loss of CMAS program delegated purchasing authority.

CMAS contractor non-compliance with the requirements may result in termination.

Page 1444 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 4

CMAS PRODUCT & SERVICE CODES
Product & Service Codes listed below are for marketing purposes only. Review the base schedule for the products and/or services available.

Brand-Act Global
Brand-Bentley
Brand-Quick Crete
Brand-Tandus
Building-Prefab Structure-Medical
Floor Cov-Broadloom Carpet
Floor Cov-Hardwood
Floor Cov-Sport Flooring
Floor Cov-Synthetic Turf
Floor Cov-Vinyl Sheeting/Tile
Playground-Equip
Sport Surface-Synthetic Track

AVAILABLE PRODUCTS AND/OR SERVICES
This CMAS provides for the purchase, warranty, removal, disposal, preparation, installation, maintenance, and repair of park and playground equipment, commercial flooring, roofing products, pre-engineered and prefabricated buildings and structures for storage solutions, hardware store products, lawn and garden equipment, heating, ventilation, and air conditioning (HVAC), energyefficient lighting, power distribution equipment, complete daycare, preschool and classroom solutions, signs, and flags.

Only the following services are available within the scope of this CMAS:

Standard Floor Preparation (So Cal)
Standard Floor Preparation (Sac)
Standard Floor Preparation (Bay Area)
Excessive Floor Preparation (So Cal)
Excessive Floor Preparation (Sac)
Excessive Floor Preparation (Bay Area)
Field Repairs
Removal of Playground Equipment
Application of Playground Equipment
Standard Floor Prep
Furniture R&R
Toilet Removal
Turf Removal
Turf Application (Standard)
Turf Application (Non- Standard)
Concrete Curb
Natural Sod Removal
Poured-In-Place Removal
Poured-In-Place Application

Page 1445 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 5 Natural Sod Application
Poured-In-Place Repair
Aggregate Base Removal
Aggregate Base Application
Logo Application
Track Surface Repair
Track Surface Re-Top
Track Surface Complete Application
Track Surface Refresh
Structural Spray Black
Structural Spray Color
Base Mat w/ Structural Spray Black
Base Mat w/ Structural Spray Color
Polyurethane Sandwich System
Polyurethane Full Pour
Track Maintenance
Substrate Prep
Substrate Compaction
Trenching
Clear, Grub and Haul
Staking
Goal Post Application
Drainage Application
Application of Sports Pad
Application of Playground Pad
Application of Infill
Application of Headerboard
Removal of Existing Surface
Application of Rubber Playground Tiles
Standard Synthetic Turf Maintenance
Premium Synthetic Turf Maintenance
Application of Asphalt
Application of Concrete
Perimeter saw cut
Application of tree wells
Application of mulch
Application of decomposed granite
Application of irrigation
Perimeter pip removal
Asphalt saw cut
Application of sealer
Re-grading base
Application of ramp
Application of grout
Scarification
Application of seeded rock
Demo Glue Down Carpet / Carpet Tile

Page 1446 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 6 Demo Powerbond Carpet/ Vinyl Backed
Demo Carpet over Pad
Demo Sheet Vinyl
Demo VCT/LVT
Demo Rubber
Skim Coat
Grind Floor
Application of Carpet Tile
Application of Powerbond Carpet
Application of Carpet Over Pad
Lift Application of Carpet Tile
Application of Sheet Vinyl
Self Cove
Application of Linoleum
Heat Weld
Application of LVT
Application of VCT
Application of Rubber Tile
4" Rubber Base
6" Rubber Base
Vinyl Transition Strips
Moisture Test
Outside Corner Installation
Removal of Degraded Seal Coats
Application of Moisture Barrier
Demo Ceramic Tile
Application of HVT
Expediting Service
Application of Self- Level Compound
Application of Ceiling Tiles
Surface Preparation for Finish
Application of Lamp Lens
Application of Retrofit LED Kit
Application of Tackboard
Application of Sound Wall
Application of Thermostats
Dumpster Service
Demo Existing Wood Flooring < 5,000sf
Demo Existing Wood Flooring > 5,000sf
Install Wood Flooring < 5,000sf
Install Wood Flooring > 5,000sf
Install Wood Subfloor < 5,000sf
Install Wood Subfloor > 5,000sf
Install Visqueen Vapor Retarder
Shim Flooring < 5,000sf
Shim Flooring > 5,000sf
Water Base Wood Floor Refinishing < 5000sf

Page 1447 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 7 Water Base Wood Floor Refinishing > 5,000sf
Oil Base Wood Floor Refinishing < 5000sf
Oil Base Wood Floor Refinishing > 5,000sf
Sand & Refinish Wood Flooring < 5,000sf
Sand & Refinish Wood Flooring > 5,000sf
Patch Wood Flooring < 5,000sf
Patch Wood Flooring > 5,000sf
Application of Additional Finish Coat
Paint Basketball Court
Paint Volleyball Court
Paint Badminton Court
Paint Pickleball Court
Paint/Stain Floor
Slab infill < 5,000sf
Slab infill > 5,000sf
Install Threshold
Install Floor Lids
Install Vent Cove Base
Paint Custom Graphics/Letters
Re-Paint Existing Game Lines
Court Design Service
GMAX Testing Procedure
Performance Testing Procedure
Air Cooled Chiller Services – Annual Cost per Chiller
Water Cooled Screw and Centrifugal Chiller Services – Annual Cost per Chiller Water Cooled Magnetic Bearing Chiller Services – Annual Cost per Chiller Heat Exchanger Services – Annual Cost per Heat Exchanger Air Compressor Services – Annual Cost per Air Compressor VFD’s and Pump Services – Annual Cost per VFD and Pump
Air – Water Separator Services – Annual Cost per Separator Application of replica plants
Application of cobble stone
Application of woodchips
Application of boulders
Application of slurry
Striping -asphalt
Natural tree - small
Natural tree - med
Natural - large
Application of natural plants
Application of pavers
Field Surveyor Service
Application of Window Treatment
The ordering agency must verify all products and/or services are currently available on the base General Services Administration (GSA) schedule.

Page 1448 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 8 Only the following job titles are available within the scope of this CMAS:

Floor Covering Journeyman (So Cal)
Floor Covering Level 1 (So Cal)
Floor Covering Level 2 (So Cal)
Floor Covering Level 3 (So Cal)
Floor Covering Level 4 (So Cal)
Floor Covering Level 5 (So Cal)
Floor Covering Level 6 (So Cal)
Floor Covering Level 7 (So Cal)
Floor Covering Level 8 (So Cal)
Floor Covering Journeyman (Bay Area)
Floor Covering Level 1 (Bay Area)
Floor Covering Level 2 (Bay Area)
Floor Covering Level 3 (Bay Area)
Floor Covering Level 4 (Bay Area)
Floor Covering Level 5 (Bay Area)
Floor Covering Level 6 (Bay Area)
Floor Covering Level 7 (Bay Area)
Floor Covering Level 8 (Bay Area)
Floor Covering Journeyman (Sac)
Floor Covering Level 1 (Sac)
Floor Covering Level 2 (Sac)
Floor Covering Level 3 (Sac)
Floor Covering Level 4 (Sac)
Floor Covering Level 5 (Sac)
Floor Covering Level 6 (Sac)
Floor Covering Level 7 (Sac)
Floor Covering Level 8 (Sac)
Flooring Project Manager
Flooring Site Supervisor
Flooring Project Coordinator
Flooring Project Estimator
Turf Project Manager
Turf Site Supervisor
Turf Project Coordinator
Turf Project Estimator
Carpenter Journeyman
HVAC Installer
HVAC Laborer
HVAC Technician
HVAC Project Manager
Site Assessment Coordinator
Tile Layer Journeyman
Quality Control Supervisor
Safety Coordination Manager
Rendering Coordinator

Page 1449 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 9 Plumber/HVAC/Electrician
Plasterer Journeyman
Cement Mason Journeyman
Drywall Lather Journeyman
The ordering agency must verify the following current information about the job titles available in the base schedule at the General Services Administration (GSA) eLibrary:
• Description of the functional requirements
• Minimum education and experience requirements
• Maximum pricing allowed (lower pricing acceptable)

FIND BASE SCHEDULE PRICING
Once on the Contractor Information page for a specific GSA schedule, the pricelist can be found either in the Contractor Terms & Conditions (T&Cs)/Pricelist document or at GSA Advantage. The Contractor T&Cs/Pricelist document is provided by the contractor as a requirement of GSA and can be found under the Contractor T&Cs/Pricelist heading by clicking on the page icon.

If the contractor has products/services available for ordering on GSA Advantage, a ‘GSA Advantage’ icon will be displayed. By clicking this image link, this will execute a search against GSA Advantage. Depending on the category, whether product or service related, will return either:
1) If products, a listing of all products available for the contractor under this contract 2) If services, the same document provided under the column Contractor T&Cs/Pricelist by clicking View Contractor Information and then View Contractor Catalog.

EXCLUDED PRODUCTS AND/OR SERVICES
The following products and services are not available under this CMAS:

The purchase of Information Technology (IT) hardware
Non-Information Technology consulting services
Public works services for State Agencies (except for resilient flooring, carpet, lighting fixtures, and synthetic turf)
Surveillance Systems
Security and Detection Systems
Physical Access Control Systems
Complete Facilities Maintenance and Management
Smart Building Systems Integration
Specialty Equipment Service
HIC Testing Procedure
Application of Interior Paint
Application of Exterior Paint
Storage Service
Electric Vehicle (EV) Charging Basic - 240 V - Up to 400A Electric Vehicle (EV) Charging Basic - 480 V - 400 to 2000A Electric Vehicle (EV) Charging Stations - Level II - 240V

Page 1450 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 10 Electric Vehicle (EV) Charging Stations – Level III - 480V Energy Efficiency Assessment I
Energy Efficiency Assessment 2
Energy Efficiency Assessment 3
Roof Mount Solar Option #1
Ground Mount Solar Option #2
Solar Carport Option #3
Procurement Coordinator
Submittals Coordinator
General Laborer Journeyman
General Laborer Material Handler Level 1
Drywall Installer Journeyman
Communications System Installer
Construction Project Supervisor
Project Specification Consultant
Project Design Consultant
Operating Engineer Journeyman
A/V Installer
Installer - Access Systems
Technician - Access Systems
Project Manager - Access Systems
Project Engineer - Access Systems
EV Installer
EV Technician
EV Project Manager
EV Project Engineer
Repair/Construction Laborer - Site Clean Up and Management Repair/Construction Laborer - Journeyman
Repair/Construction Laborer - Skilled and Trained
Repair/Construction Laborer – Apprentice
Repair/Construction Laborer - Equipment Operator
Order-Level Materials (OLM)

ISSUE PURCHASE ORDER TO
Agency purchase orders must be sent to the following:

KYA Services, LLC
1800 E McFadden Avenue
Santa Ana, CA 92705-4708
Attn: Lisa Chavez
E-mail: [email protected]

Page 1451 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 11 Agencies with questions regarding products and/or services may contact the CMAS contractor as follows:

Contact: Lisa Chavez
Phone: (714) 659-6477
E-mail: [email protected]
Website: https://www.thekyagroup.com/
TOP 500 DELINQUENT TAXPAYERS
In accordance with Public Contract Code (PCC) 10295.4, and prior to placing an order for non-IT goods and/or services, agencies must verify with the Franchise Tax Board and the California Department of Tax and Fee Administration that this CMAS contractor’s name does not appear on either list of the 500 largest tax delinquencies pursuant to Revenue and Taxation Code 7063 or 19195. The Franchise Tax Board’s list of Top 500 Delinquent Taxpayers is available at their website. The California Department of Tax and Fee Administration’s list of Top 500 Sales & Use Tax Delinquencies in California is available at their website.

CALIFORNIA SELLER’S PERMIT
The CMAS contractor’s California Seller’s Permit Number is 102-369022. Prior to placing an order with this company, agencies must verify that this permit is still valid at the California Department of Tax and Fee Administration website.

MINIMUM ORDER LIMITATION
The minimum dollar value of an order to be issued under this CMAS is $100.

CMAS PRICES
The maximum prices allowed for the products and/or services available are those set forth in the base schedule.

The ordering agency is encouraged to seek prices lower than those in the base schedule. When responding to an agency’s Request for Offer (RFO), the CMAS contractor can offer lower prices to be competitive.

PRICE DISCOUNTS
This CMAS contains dollar volume and prompt payment discounts. See the base schedule for the specific discount percentage.

DARFUR CONTRACTING ACT
This CMAS contractor has certified compliance with the Darfur Contracting Act, per PCC 10475. It is the agency’s responsibility to verify that the contractor has a Darfur Contracting Act Certification on file.

Page 1452 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 12

IRAN CERTIFICATION
This CMAS contractor has certified compliance with the Iran Contracting Act, per PCC 2001-2008.

It is the agency’s responsibility to verify that the contractor has an Iran Contracting Act Certification on file.

CALIFORNIA CIVIL RIGHTS LAW CERTIFICATION
Pursuant to PCC 2010 applicants must certify their compliance with the California Civil Rights laws and Employer Discriminatory Policies (Civil Code 51, GC 12960). It is the agency’s responsibility to verify that the contractor has a California Civil Rights Law Certification on file.

WARRANTY
For warranties, see the base schedule and the CMAS Warranty provision in the CMAS Special Provisions.

CMAS contractor personnel shall have the experience, education, and expertise as defined in the base schedule.

DELIVERY
As negotiated between agency and CMAS contractor and included in the purchase order.

LIQUIDATED DAMAGES FOR LATE DELIVERY
The value of the liquidated damages cannot be a penalty, must be mutually agreed upon by agency and contractor and included in the purchase order to be applicable.

SHIPPING INSTRUCTIONS
F.O.B. (Free On Board) Origin. Buying agency pays the freight charges.

State agencies shall follow the instructions below whenever the weight of the purchase is 100 lbs. or more and F.O.B. Destination, Freight Prepaid is not used. This requirement is not applicable to local government agencies.

All shipments will be made by ground transportation unless otherwise ordered on the purchase order.

Traffic Management Unit (TMU) approval is not required for any Leveraged Procurement Agreement negotiated by DGS; however, it is recommended that state agencies contact TMU for a freight weight comparison using the Freight Analysis Worksheet on the TMU website, under the “Forms” heading to ensure the state is getting the most reasonable shipping cost.

Note: If shipping charges for purchases weighing less than 100 lbs. appear to be excessive (e.g., $500 for a 5 lb. package where the shipping charge is a percentage of the cost of the item being purchased), departments are encouraged to contact TMU for help to obtain more appropriate pricing. TMU contact information can be found at the TMU website.

Page 1453 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 13

PURCHASING AUTHORITY DOLLAR THRESHOLD
Order limits for the purchase of goods and/or services is determined by the individual agency purchasing authority threshold.

No CMAS order may be executed by a State agency that exceeds that agency’s purchasing authority threshold, unless an exemption is granted by the Department of General Services (DGS) Purchasing Authority Unit (PAU). State agencies with approved purchasing authority, along with their dollar thresholds can be obtained at the List of State Departments with Approved Purchasing Authority website.

HOW TO USE CMAS
State agencies must adhere to the requirements in the State Contracting Manual (SCM) Volume 2, Chapter 1600 and CMAS Ordering Instructions and Special Provisions when using CMAS. • Develop an RFO, which includes a Scope of Work (SOW) and Bidder Declaration form. For information on the Bidder Declaration requirements see SCM, Volume 2, Sections 305 and 1202.
• Clearly defined Tasks (what needs to be done) and Deliverables (outcome of each task, i.e., reports, procedures manual, etc.) must be included in the State’s SOW. • A Work Order Authorization (WOA) may be used to document completion of pre-determined tasks, but only if the tasks are clearly defined in the SOW. The WOA may be used to approve release for the next phase of the agreement but cannot be used to identify any tasks other than the ones called out in the SOW. The WOA will be signed by all parties and may be submitted for progress payments under the award. • Projects can be performed on a Fixed Price Per Deliverable (FP/D). Fixed Price; FP/D: A defined service, or set of services, performed by Contractor in response to a defined task, or set of tasks, at a specific fixed price, and delivered per a specific schedule. Note: When using FP/D the Statement of Work must describe in detail the particular project and the work that the selected Qualified Contractor will be required to perform. • For Consulting or Personal services, do not include any labor categories/job titles or number of hours limit in RFO Requirements or the SOW. The CMAS Contractor provides this information in their Attachment B Cost Worksheet. The State does not have the expertise to make this decision (GC 19130(b)).
• Search for potential CMAS contractors on the CMAS website and select “Find a CMAS Contractor.”
• Request offers from a minimum of 3 CMAS contractors including one small business (SB) and/or Disabled Veteran Business Enterprise (DVBE), if available, who are authorized to sell the products and/or able to perform the services needed. (Government Code 14846(b)). • A valid attempt must be made to secure offers from viable CMAS contractors who are able to supply the goods and/or provide the services. Neither a lack of sufficient CMAS contractors nor the use of restrictive requirements meets the intent for obtaining offers (SCM Volume 2, Section 1670.2).

Page 1454 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 14 • If requesting offers from a certified DVBE, include the Disabled Veteran Business Enterprise Declarations form (Standard 843) in the RFO. This declaration must be completed by the DVBE prime contractor and/or any DVBE subcontractors and submitted with the offer (SCM Volume 2, Section 1201).
• This is not a bid transaction, so the small business preference, DVBE incentives, protest language, intent to award, evaluation criteria, advertising, Administrative and Technical Requirements, etc. are not applicable. (SCM Volume 2, Section 1603). • If less than 3 offers are received, State agencies must document their file with the reasons why the other suppliers did not respond with an offer. The reason must come from the CMAS contractor.
• Assess the offers received using best value criteria including cost as one of the criteria (SCM Volume 2, Section 1603).
• Issue a Purchase Order to the selected CMAS contractor. • For CMAS transactions under $10,000, only one offer is required if the State agency can establish and document that the price is fair and reasonable. The fair and reasonable method can only be used for non-customizable purchases. See SCM Volume 2, Section 1510 for Fair and Reason criteria.

Local agencies must follow their own procurement regulations. For more information see the Local Agency packet available online.

AGENCY RESPONSIBILITY
Each agency is responsible for its own contracting program and purchasing decisions, including use of the CMAS program and associated outcomes. This responsibility includes, but is not limited to, ensuring the necessity of the services, securing appropriate funding, complying with laws and policies, preparing the purchase order in a manner that safeguards the State’s best interests, obtaining required approvals, and documenting compliance with GC 19130.b(3) for outsourcing services.

It is the responsibility of each agency to consult with their legal staff and contracting offices for advice depending upon the scope or complexity of the purchase order. If legal services are not available within your agency, DGS Office of Legal Services is available to provide services.

CONFLICT OF INTEREST
Agencies must evaluate the proposed purchase order to determine if there are any potential conflict of interest issues. See the CMAS Special Provisions, Conflict of Interest, for more information.

Page 1455 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 15

SPLITTING ORDERS
Splitting orders to avoid any monetary limitations is prohibited. Do not circumvent normal procurement methods by splitting purchases into a series of delegated purchase orders per PCC 10329. Splitting a project into small projects to avoid either fiscal or procedural controls is prohibited per State Administrative Manual (SAM) 4819.34.

This provision does not apply to local government agencies.

ORDERING PROCEDURES

1. Purchase Orders
All Ordering Agency purchase order documents executed under this CMAS must contain the applicable CMAS number as show on page 1.
a. State Departments:

Standard 65 Purchase Documents – State departments not transacting in FISCal must use the Purchasing Authority Purchase Order (Standard 65) for purchase execution. An electronic version of the Standard 65 is available at the Department of General Services (DGS), Procurement Division (PD) website, select Standard (STD) Forms.

FISCAL Purchase Documents – State departments transacting in FISCal will follow the FISCal procurement and contracting procedures.
b. Local Government Agencies:

Local government agencies may use their own purchase order document for purchase execution.

The agency is required to complete and distribute the purchase order. For services, the agency shall modify the information contained on the order to include the service period (start and end date), the monthly cost (or other intermittent cost), and any other information pertinent to the services. The cost for each line item must be included in the order, not just system totals.

The contractor must immediately reject purchase orders that are not accurate. Discrepancies are to be negotiated and incorporated into the purchase order prior to product delivery and service implementation.

2. Service and Delivery after CMAS Expiration
The purchase order must be issued before the CMAS expires. However, delivery of the products or completion of the services may be after the CMAS expires (unless otherwise specifically stated in the purchase order). Amending the purchase order to add quantity, time, or money is not possible if the CMAS expired.

Page 1456 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 16

3. Multiple CMAS Agreements on a Single Purchase Order
State agencies wishing to include multiple CMAS agreements on a single FISCal purchase order must adhere to the following guidelines:
• All CMAS must be for the same CMAS contractor.
• The purchase order must go to one contractor location. • Enter the word “CMAS” in the space reserved for the Leveraged Procurement Agreement (LPA) number. The word “CMAS” signifies that the purchase order contains items from multiple CMAS agreements. The purchasing agency may only use one bill code. • For each individual CMAS, the agency must identify and group together the CMAS number with the line items and subtotal per CMAS number (do not include tax in the subtotal), and sequentially identify each individual CMAS as Sub #1, Sub #2, Sub #3, etc. This facilitates accurate billing of administrative fees by the Procurement Division. • The total of all items on the purchase order must not exceed the State agency’s purchasing authority dollar threshold granted by DGS PAU.
• Do not combine items from IT and non-IT CMAS agreements. An Information Technology CMAS begins with the number “3” and a non-IT CMAS begins with the number “4.” The purchase order limits are different for these CMAS agreements.

4. Amendments to State Agency's Purchase Orders
Agency purchase orders cannot be amended if the CMAS has expired.

SCM, Volume 2, Section 1605 provides the following directions regarding amendments to all types of LPA purchase orders:

Original orders, which include options for changes (e.g., quantity or time), that were assessed and considered in the selection for award during the RFO process, may be amended consistent with the terms of the original order, provided that the original order allowed for amendments. If the original order did not evaluate options, then amendments are not allowed unless an Non-Competitively Bid is approved for those amendments.

Amendments unique to Non-IT Services:

If the original contract permitted amendments, but did not specify the changes, (e.g., quantity or time), it may be amended. Per PCC 10335 (d)(1), a contract may only be amended once under this exemption. The time shall not exceed one year, or add not more than 30 percent of the original order value and may not exceed $250,000. If the original contract did not have language permitting amendments, the Non-Competitively Bid process must be followed.

CMAS CONTRACTOR OWNERSHIP INFORMATION
The CMAS contractor is a large business enterprise.

Page 1457 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 17

SMALL BUSINESS MUST BE CONSIDERED
Prior to placing orders under the CMAS program, State agencies must first consider offers from small businesses that have established CMAS agreements (GC 14846(b)). NOTE: DGS auditors will request substantiation of compliance with this requirement when agency files are reviewed.

CMAS Small Business and Disabled Veteran Partners can be found on the CMAS website by selecting “Find a CMAS Contractor”.

In response to our commitment to increase participation by small businesses, the Department of General Services waives the administrative fee (charged to customer agencies to support the CMAS program) for orders to California certified small business enterprises.

SMALL BUSINESS/DVBE - TRACKING
State agencies are able to claim subcontracting dollars towards their SB or DVBE goals whenever the CMAS contractor subcontracts a commercially useful function to a certified SB or DVBE. The CMAS contractor will provide the ordering agency with the name of the SB or DVBE used and the dollar amount the ordering agency can apply towards its SB or DVBE goal.

SMALL BUSINESS/DVBE - SUBCONTRACTING

1. The amount an ordering agency can claim towards achieving its SB or DVBE goals is the dollar amount of the subcontract award made by the CMAS contractor to each SB or DVBE.

2. The CMAS contractor will provide an ordering agency with the following information at the time the order is quoted:
a. The CMAS contractor will state that, as the prime contractor, it shall be responsible for the overall execution of the fulfillment of the order.
b. The CMAS contractor will indicate to the ordering agency how the order meets the SB or DVBE goal, as follows:
i. List the name of each company that is certified by the Office of Small Business and DVBE Services that it intends to subcontract a commercially useful function to; and ii. Include the SB or DVBE certification number of each company listed and attach a copy of each certification; and
iii. Indicate the dollar amount of each subcontract with a SB or DVBE that may be claimed by the ordering agency towards the SB or DVBE goal; and iv. Indicate what commercially useful function the SB or DVBE subcontractor will be providing towards fulfillment of the order.

3. The ordering agency’s purchase order must be addressed to the prime contractor, and the purchase order must reference the information provided by the prime contractor as outlined above.

Page 1458 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 18

CONTRACTORS ACTING AS FISCAL AGENTS ARE PROHIBITED
When a subcontractor ultimately provides all of the products or performs all of the services that a CMAS contractor has agreed to provide, and the prime contractor only handles the invoicing of expenditures, then the prime contractor's role becomes that of a fiscal agent because it is merely administrative in nature and does not provide a Commercially Useful Function. It is unacceptable to use fiscal agents in this manner because the agency is paying unnecessary administrative costs.

WITHHOLD LANGUAGE (SB588)
Upon delivery or completion of ordered goods or services for which the Contractor committed to DVBE subcontractor participation, state departments must require the Contractor to certify all the following:

1. The amount and percentage of work the Contractor committed to provide to one or more DVBEs under the requirements of the contract and the amount each DVBE received from the Contractor.

2. That all payments under the contract have been made to the DVBE. Upon request, the Contractor must provide proof of payment for the work.

In accordance with the Military and Veterans Code 999.7, state departments shall withhold $10,000 from the final payment, or the full final payment if less than $10,000, if the Contractor fails to meet the certification requirements identified above. State departments shall notify the Contractor of their failure to meet the certification requirements and give the Contractor an opportunity to comply with the certification requirements. If after 30 calendar days from the date of notice, the Contractor refuses to comply with the certification requirements, the state department shall permanently deduct $10,000 from the final payment or the full payment if less than $10,000.

PRODUCT SUBSTITUTIONS
Substitution of Deliverables may not be tendered without advance written consent of the Buyer.

The Contractor must offer an equivalent or newer model of the product from the same manufacturer at the same or lower price. Contractor cannot use any specification in lieu of those contained in the Contract without written consent from the Buyer.

NEW EQUIPMENT REQUIRED
The State will procure new equipment. All equipment must be new (or warranted as newly manufactured) and the latest model in current production. Used, shopworn, demonstrator, prototype, or discontinued models are not acceptable.

Where Federal Energy Management Program (FEMP) standards are available, all State agencies shall purchase only those products that meet the recommended standards. All products displaying the Energy Star label meet the FEMP standards.

Page 1459 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 19

SPECIAL MANUFACTURED GOODS
Any CMAS for goods to be manufactured by the CMAS contractor specifically for the State and not suitable for sale to others may require progress payments.

For a Non-IT goods CMAS, see the CMAS Non-IT Commodities Special Provisions, Provision #14, Progress Payments.

TRADE-IN EQUIPMENT
Trade-ins at open market price may be considered. The product description and trade-in allowance must be identified on the purchase order.

Agencies are required to adhere to SAM 3520 through 3520.6, Disposal of Personal Property and Surplus Personal Property, as applicable, when trade-ins are considered. A Property Survey Report, Standard 152, must be submitted for approval prior to disposition of any State owned personal property, including general office furniture regardless of the acquisition value, or if the property was recorded or capitalized for accounting purposes.

STATE AGENCY BUY RECYCLED CAMPAIGN
State ordering agencies are required to report purchases made within the eleven product categories in the California Department of Resources Recycling and Recovery’s State Agency Buy Recycled Campaign per PCC 12200 through 12217.

Contractor will be required to complete and return a Recycled-Content Certification form upon request by the state ordering agency.

ACCEPTANCE TESTING CRITERIA
If the agency wants to include acceptance testing for all newly installed technology systems, individual equipment, and machines which are added or field modified (modification of a machine from one model to another) after a successful performance period, the test criteria must be included in the purchase order to be applicable.

PRODUCT INSTALLATION
The CMAS contractor is fully responsible for all installation services performed under the CMAS.

Product installations must be performed by manufacturer authorized personnel and meet manufacturer documented specifications.

The prime contractor, as well as any subcontractors, must hold any certifications and/or licenses required for the project.

Page 1460 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 20 PILOT PROGRAM: ALTERNATIVE CONTRACTING PROCEDURES FOR PUBLIC WORKS

INSTALLATION
Public Contract Code (PCC) 10298.5 establishes a pilot program for alternative contracting procedures for certain public works installations not including new construction. This program only applies to the installation, or purchase and installation, of resilient flooring, carpet, lighting fixtures, and synthetic turf. The program modifies existing rules which restrict State agencies from using CMAS agreements for public works contracts wherein the cost of the public works services exceeds the cost of the materials being purchased. State and local agencies should refer to PCC Section 10298.5 for additional requirements including the requirement to notify the Department of Industrial Relations in accordance with Section 1773.3 of the Labor Code.

This program expires January 1, 2028.

Suppliers and contracting agencies must comply with all requirements for this program as defined in Public Contract Code 10298.5.

PUBLIC WORKS (INSTALLATION SERVICES ONLY)
A public works contract is defined as an agreement for “the erection, construction, alteration, repair, or improvement of any public structure, building, road, or other public improvement of any kind” in accordance with PCC 1101. State agencies planning these types of projects need to review SCM, Volume 1, Chapters 10 and 11 for applicable guidelines and regulations. Visit the DGS, Real Estate Services Division (RESD) website if you have questions about public works transactions.

Agency CMAS purchase orders may allow for public works installation only when it is in support of the products covered by this CMAS.

Agencies are to ensure that the applicable laws and codes pertaining to the contractor and subcontractor licensing, prevailing wage rates, bonding, labor code requirements, etc. are adhered to by the prime contractor as well as any subcontractor during performance under the CMAS purchase order.

The bond amount for public works is not less than 100% of the purchase order price.

NOTE: In accordance with Labor Code (LC) 1773.2, the ordering agency is responsible for determining the appropriate craft, classification or type of worker needed for any contract for public works. Also, the agency is to specify the applicable prevailing wage rates as determined by the Director of the Department of Industrial Relations (DIR). In lieu of specifying the prevailing wage rates, the agency may include a statement on the order that the prevailing wage rates are on file at the agency’s office and will be made available upon request. The prevailing wage rates are available from DIR at www.dir.ca.gov (select Statistics & Research).

Bonds: For guidelines, see CMAS, Special Provisions, Public Works Requirements.

Page 1461 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 21 State Contractor’s License: Public works services can be obtained through CMAS only if incidental to the overall purchase order. If incidental public works services are included in the purchase order, prior to issuing the order agencies should visit the State Contractor’s License Board website to verify that the Contractor’s License shown below is still active and in good standing.

The CMAS contractor’s California Contractor's License number is 984827. This is a Class C15 - Flooring and Floor Covering, B - General Building, C-61 / D12 - Synthetic Products, A - General Engineering, C20 - Warm-Air Heating, Ventilating and Air-Conditioning, and C10 – Electrical license that is valid through 06/30/2025.

NOT SPECIFICALLY PRICED ITEMS
The only time that open market/incidental, non-schedule items may be included in a CMAS order is when they fall under the parameters of the Not Specifically Priced (NSP) Items provision.

CMAS contractors must be authorized providers of the hardware, software and/or services they offer under the NSP Items provision.

Agency and CMAS contractor use of the NSP provision is subject to the following requirements:

1. Purchase orders containing only NSP items are prohibited.

2. A purchase order containing NSP items may be issued only if it results in the lowest overall alternative to the State.

3. NSP items shall be clearly identified in the order. Any product or service already specifically priced and included in the base schedule may not be identified as an NSP item.

4. NSP Installation Services: The CMAS contractor is fully responsible for all installation services performed under the CMAS. Product installations must be performed by manufacturer authorized personnel and meet manufacturer documented specifications. The prime contractor, as well as any subcontractors, must hold any certifications and/or licenses required for the project. The total dollar value of all installation services included in the purchase order cannot exceed the dollar value of the products included in the purchase order, nor can they exceed the NSP Maximum Order Limitation.

5. Maximum Order Limitation: For orders $250,000, or less, the total dollar value of all NSP items included in a purchase order shall not exceed $5,000. For orders exceeding $250,000, and at the option of the contractor, the total dollar value of all NSP items in a purchase order shall not exceed 5% of the total cost of the order or $25,000 whichever is lower.

Page 1462 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 22

6. An NSP item included in an order issued against this CMAS is subject to all of the terms and conditions set forth in the CMAS.

7. Trade-ins, upgrades, involving the swapping of boards, are permissible, where the contract makes specific provisions for this action. In those instances, where it is permitted, the purchase order must include the replacement item and a notation that the purchase involves the swapping of a board.

The following NSP items are specifically excluded from any order issued under this CMAS:

1. Items not intended for use in direct support of the priced items included in the same order.

An NSP item must be subordinate to the specifically priced item that it is supporting. For example, a cable, which is not otherwise specifically priced in the base schedule, is subordinate to a specifically priced printer and is eligible to be an NSP item subject to that cable meeting the remaining NSP requirements. However, a printer that is not otherwise specifically priced in the base schedule, is not subordinate to a specifically priced cable and is not eligible to be an NSP item.

2. Supply type items, except for the minimum amount necessary to provide initial support to the priced items included in the same order.

3. Items that do not meet the Productive Use Requirements for information technology products, per Statewide Information Management Manual Section 195.

4. Any other item or class of items specifically excluded from the scope of this CMAS.

5. Public Works and other services NOT in support of the products covered by this CMAS.

6. Products or services the CMAS contractor is NOT factory authorized or otherwise certified or trained to provide.

7. Follow-on consultant services that were previously recommended or suggested by the same CMAS contractor.

The CMAS contractor is required to reject purchase orders containing NSP items that do not comply with the above requirements. The CMAS contractor will promptly notify the agency issuing the noncompliant order of its rejection and the reasons for its rejection.

STATE AND LOCAL GOVERNMENTS CAN USE CMAS
State and local government agency use of CMAS is optional. A local government is any city, county, city and county, district, or other local governmental body or corporation, including Universities of California, California State Universities, K-12 schools, and community colleges empowered to expend public funds. While the State makes this CMAS available, each local government agency should make its own determination whether the CMAS program is consistent with its procurement policies and regulations.

Page 1463 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 23 PCC 10298 allows any city, county, city and county, district, or other local governmental body or corporation empowered to expend public funds to contract with suppliers awarded CMAS without further competitive bidding. See complete PCC 10298 language at the California Legislative Information website.

PCC 10299 allows any school district empowered to expend public funds to utilize CMAS without further competitive bidding. See complete PCC 10299 language at the California Legislative Information website.

SELF-DELETING BASE SCHEDULE TERMS AND CONDITIONS
Instructions or terms and conditions that appear in the Special Items or other provisions of the base schedule and apply to the purchase, license, or rental (as applicable) of products or services by the US Government in the United States and/or to any overseas location shall be self-deleting. (Example: "Examinations of Records" provision).

Federal regulations and standards, such as Federal Acquisition Regulation, Federal Information Resources Management Regulation, Federal Information Processing Standards, General Services Administration Regulation, or Federal Installment Payment Agreement shall be self-deleting.

Federal blanket orders and small order procedures are not applicable.

ORDER OF PRECEDENCE
The CMAS Special Provisions take precedence if there is a conflict between the terms and conditions of the contractor's base schedule, packaging, invoices, catalogs, brochures, technical data sheets, or other documents (see CMAS Special Provisions, CONFLICT OF TERMS).

APPLICABLE CODES, POLICIES AND GUIDELINES
All California codes, policies, and guidelines are applicable. The use of CMAS does not relieve state agencies of their responsibility to meet statewide requirements regarding contracting or the procurement of goods or services. Most procurement and contract codes, policies, and guidelines are incorporated into CMAS agreements; however, there is no guarantee that every requirement that pertains to all State processes has been included.

PAYMENTS AND INVOICES
This CMAS contains prompt payment discounts. See the base schedule for the specific discount percentage.

1. Payment Terms
Payment terms for this CMAS are net 45 days.

Payment will be made in accordance with the provisions of the California Prompt Payment Act, GC 927. Unless expressly exempted by statute, the Act requires State agencies to pay properly submitted, undisputed invoices not more than 45 days after (1) the date of acceptance of goods or performance of services; or (2) receipt of an undisputed invoice, whichever is later.

Page 1464 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 24

2. Payee Data Record (Standard 204)
State Agencies must obtain a copy of the Payee Data Record (Standard 204) in order to process payments. State Ordering Agencies must forward a copy of the Standard 204 to their accounting offices. Without the Standard 204, payment may be unnecessarily delayed. State Agencies should contact the CMAS contractor for copies of the Payee Data Record.

3. DGS Administrative and Incentive Fees
Orders from State Agencies:

DGS will bill each State agency directly an administrative fee for use of CMAS. The administrative fee should NOT be included in the order total or remitted before an invoice is received from DGS. This administrative fee is waived for CMAS purchase orders issued to California certified small businesses.

Orders from Local Government Agencies:

CMAS contractors, who are not California certified small businesses, are required to remit to DGS an incentive fee equal to a percentage of the total of all local government agency orders (excluding sales tax and shipping) placed against their CMAS.

The incentive fee is waived for CMAS purchase orders issued to California certified small businesses.

For more information on the incentive fees see the CMAS Management Guide.

4. Contractor Invoices
Unless otherwise stipulated, the CMAS contractor must send their invoices to the agency address set forth in the purchase order. Invoices shall be submitted in triplicate and shall include the following:
• CMAS number
• Agency purchase order number
• Agency Bill Code (State Only)
• Line item number
• Unit price
• Extended line item price
• Invoice total
State sales tax and/or use tax shall be itemized separately and added to each invoice as applicable.

The company name on the CMAS, purchase order and invoice must match, or the State Controller’s Office will not approve payment.

Page 1465 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 25

5. Advance Payments
Advance payment is allowed for services only under limited, narrowly defined circumstances, i.e., between specific departments and certain types of non-profit organizations, or when paying another government agency (GC 11256 through 11263 and 11019).

It is NOT acceptable to pay in advance, except software maintenance and license fees, which are considered a subscription and may be paid in advance if a provision addressing payment in advance is included in the purchase order.

Software warranty upgrades and extensions may also be paid for in advance, one time.

6. Credit Card
The CMAS contractor does not accept the State of California credit card (VISA CAL-Card).

7. Leasing/Financing
California State Agencies should use the Golden State Financial Marketplace (GS SMart) program for all financing and leasing needs. California Local Government Agencies (counties, cities, K-12 school districts, community colleges, California State Universities, Universities of California, etc.) may utilize the GS SMart program for financing and leasing according to PCC 14937. The minimum dollar amount for Local Government Agency financing and leasing is $100,000.

8. Lease/Purchase Analysis
California State agencies must complete a Lease/Purchase Analysis (LPA) to determine best value when contemplating a lease/rental and retain a copy for future audit purposes (SAM 3710).

For short-term rental equipment, the lease/purchase analysis must be approved by DGS Office of Legal Services.

The lease/purchase analysis for all other purchases must be approved by the Department of General Services, GS SMart State Financial Marketplace. Buyers may contact the GS SMart Unit via e-mail at [email protected] for further information.

9. Leasing
The State reserves the right to select the form of payment for all procurements, whether it is an outright purchase with payment rendered directly by the State, or a financing/lease-purchase or operating lease via the State Financial Marketplace (GS SMart and/or Lease SMart). If payment is via the financial marketplace, the CMAS contractor will invoice the State and the State will approve the invoice. The selected Lender/Lessor for all product listed on the State’s procurement document will pay the supplier on behalf of the State. Buyers may contact the GS SMart Unit via e-mail at [email protected] for further information.

Page 1466 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 26

10.Maintenance Tax
The California Department of Tax and Fee Administration has ruled that in accordance with Section 1546 of the Sales and Use Tax Regulations of the Business Taxes Law Guide, whenever optional maintenance contracts include consumable supplies, such supplies are subject to sales tax.

Generally, the State has two options:

1. For agreements that provide for only maintenance services (i.e., the furnishing of labor and parts necessary to maintain equipment), the charges for the provision of maintenance services are not taxable.

2. For agreements that provide for both maintenance services and consumable supply items (e.g., toner, developer, staples), the provision of the consumable supplies is considered a taxable sale of tangible personal property. Therefore, State agencies awarding optional maintenance contracts are responsible for paying the applicable sales tax on the consumable supplies used during the performance period of the maintenance contract.

The Contractor will be required to itemize the taxable consumables for State accounting purposes.

OBTAINING COPY OF CMAS
A copy of this CMAS can be obtained at Cal eProcure. Links to the CMAS Special Provisions conditions and base schedule are available on the front page of this CMAS agreement.

It is important for the agency to confirm that the required products, services, and prices are included in the CMAS and are at or below base schedule rates. To streamline verification that the needed items are in the base schedule, the agencies should ask the CMAS contractor to identify the specific location in the base schedule that include the required products, services, and prices.

Once verified, agencies should save the information for their file documentation.

FEDERAL DEBARMENT
When federal funds are expended, the agency is required to obtain (retain in file) a signed “Federal Debarment” certification from the CMAS contractor before the purchase order is issued. This certification is required by the regulations implementing Executive Order 12549, Debarment and Suspension, 29 CFR Part 98, Section 98.510, Participants; responsibilities. The regulations were published as Part VII of the May 26, 1988 Federal Register (pages 19160-19211).

CONTRACTOR TRAVEL
The Travel provision is not applicable to this CMAS.

AMERICANS WITH DISABILITY ACT
To view the DGS Accessibility Policy, please visit the DGS website.

Page 1467 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 27 Information Regarding the Purchase and Installation of Floor Coverings A contract for the purchase and installation of carpet and other floor coverings is a public works contract as defined in Section 1101 of the Public Contract Code and, as such, requires certain special conditions.

A state agency may not contract for the installation of carpet in a building (a capital improvement to the building) that is not owned by the state. Carpet in leased facilities must be provided by the lessor and is accounted for in the lease agreement and rate. Users should contact the building manager and or the building owner when carpet is required.

A supplier or installer of carpet must be licensed by the State Contractors’ Licensing Board with a C-15 Flooring and Floor Covering license which is current and in good standing. The supplier must provide the license number and expiration date for themselves and for all subcontractors providing installation services. This information shall be provided by the supplier on the “Contractors’ License Requirements” form (see attached Sample A), which must be attached to each resulting carpet order. A subcontractor is defined as anyone who will perform work, labor, or render services in an amount in excess of one-half of one percent of the total order. Each subcontractor’s business address and the portion of work that each will perform shall also be included on this form.

If the contract amount exceeds $5,000 (labor/installation costs), the supplier must furnish a payment bond (Std. 807 - see attached Sample B) prior to the commencement of performance.

The payment bond shall be in a sum not less than one hundred percent (100%) of the contract price. A blank copy of the Std. 807 form shall be provided to the supplier. In addition, the awarding agency must notify the contractor that the contract is subject to state contractor nondiscrimination and compliance requirements (see paragraph 42 of the CMAS Terms and Conditions).

The prevailing wage requirements apply and a list of prevailing wage rates must be available for inspection. It is the ordering agency’s responsibility to provide a copy of the prevailing wage rates to the contractor. The prevailing wage rates are available from the Department of Industrial Relations, Prevailing Wage Unit at www.dir.ca.gov (select Statistics & Research) or at (415) 703- 4774.

Agencies should be aware that there are certain requirements that pertain to floor coverings included in the Americans with Disabilities Act of 1992 (ADA). Some of these requirements pertain to carpet pile height (not to exceed 1/2” in height), fastening exposed carpet edges to floor, and changes in floor level not to exceed 1/2” beveled. It is the responsibility of the agency to comply with these requirements. Detailed information relative to carpet installation and ADA requirements can be obtained from the State Architect, Access Compliance Unit, at (916) 445-7523.

Agencies should be aware that old flooring material (tiles, glues, cove base, etc.) may contain asbestos and could present significant problems in the removal of old flooring material and in the installation of new carpet. Users should determine the presence or absence of asbestos containing material in their existing flooring materials and act accordingly before placing orders for carpet.

It is strongly recommended that new carpet not be installed over existing carpet due to potential conflicts with the Americans with Disabilities Act, and various fire, health and safety codes.

Page 1468 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 28 The moisture content of the slab over which the carpet is to be installed must be within the limits allowed by the carpet manufacturer and/or glue manufacturer. The testing of slab moisture content can be performed by either the agency ordering the carpet or by the carpet supplier.

The agency should provide for a site inspection prior to issuing an order for the carpet desired and should use a checklist similar to the one attached (see attached Sample C). Additions, changes, modifications to the checklist should be made as necessary. The agency should inspect and monitor the progress of the installation to prevent problems.

The prime responsibility for contract performance rests with the contract holder, who shall be the primary contact point for problem resolution. This contract is structured such that the user may purchase carpet only or carpet installed from the supplier. In no case is the supplier allowed to deny installation of the carpet selected by any user for any location. Installation services may not exceed an amount equal to the cost of the carpet and, when identified, will be paid for in the cost of the CMAS order. Typically, the price schedule will contain pricing for “clean floor” (new) installation only. However, agencies may use the Not Specifically Priced (NSP) provision for “unclean floor” installation services, as well as products. The total dollar value of all installation services, on clean and/or unclean surfaces, using line item and/or NSP pricing, must not exceed 50% of the order’s total value.

The cost of installation and any ancillary supplies/services is not included in the base price of the carpet and may be obtained from the price schedule if listed, or can otherwise be included via the NSP provision.

It is incumbent upon the user to identify whether the costs for installation and other requirements are fair and equitable. The following chart is provided to give an approximation of the costs for installation in several typical state locations.

Page 1469 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 29

ESTIMATED CARPET INSTALLATION COSTS
(NOTE: THESE ARE APPROXIMATIONS ONLY, NOT ACTUAL CONTRACT INSTALLATION PRICES. DOES NOT INCLUDE COST OF NEW CARPET.)

BASED ON WEEKDAY INSTALLATION, NORMAL WORKING HOURS, PREVAILING WAGE, NO

UNIQUE CONDITIONS
Description Of Installation Estimated Installation Cost (per square yard)
General Office Space
New Construction
Clean Floor
Install New Carpet Direct Glue Down or Full Spread Release Adhesive Non-Patterned Carpet
Broadloom $4.00
Modular (Tile) $4.00
General Office Space
No Furniture Moving
Remove Old Direct Glue Carpet
Install New Carpet Direct Glue Down or Full Spread Release Adhesive Non-Patterned Carpet
Broadloom $5.00
Modular (Tile) $5.00
General Office Space
Moving of Conventional Furniture
Remove Old Direct Glue Carpet
Install New Carpet Direct Glue Down or Full Spread Release Adhesive Non-Patterned Carpet
Broadloom $10.00
Modular (Tile) $10.00
General Office Space
Moving of Modular (Panels And Components) Furniture
Remove Old Direct Glue Carpet
Install New Broadloom Carpet Direct Glue Down
Non-Patterned Carpet
Broadloom $5.00
Plus $300.00-$400.00 Per Workstation
General Office Space
Lifting of Modular (Panels And Components) Furniture
Remove Old Direct Glue Carpet
Install New Modular Carpet Full Spread Release Adhesive Modular (Tile) $11.00

Page 1470 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 30

CARPET TYPES FOR GIVEN AREAS (GENERAL GUIDELINE ONLY)
Area To Be Carpeted Carpet Type
General Office
(Example: General State Offices with No
Or Light To Medium Public Traffic)
26-28 Ounce Broadloom, Commercial Grade, Loop Pile, Nylon, Dupont Lumina or Legacy Or Basf 2000zx Yarn System. Installation by Direct Glue Down.

Or
26-28 Ounce Modular (Carpet Tile), Commercial Grade, Loop Pile, Nylon, Dupont Lumina or Legacy Or Basf 2000zx Yarn System. Installation With Full Spread Of Release Adhesive.

Executive Offices
(Example: Director’s Office, Deputy
Directors, Agency Personnel
28-32 Ounce Broadloom, Commercial Grade, Tufted Graphics Design, Loop Pile, Nylon, Dupont Lumina or Legacy Or Basf 2000zx Yarn System.

Installation by Direct Glue Down.

Or
28-32 Ounce Modular (Carpet Tile), Commercial Grade, Tufted Graphics Design, Loop Pile, Nylon, Dupont Lumina or Legacy Or Basf 2000zx Yarn System. Installation With Full Spread Of Release Adhesive.

State Owned Residences 34 Ounce Broadloom, Tufted, Commercial Grade, Cut and Loop Pile. Yarn to Be Branded Nylon, Any Conventional Dye Method. Installation Stretch In Over 3/8 Inch, 100% Synthetic Carpet Cushion, 28 Ounce Per Square Yard Nominal, 6.2 Pound Per Cubic Foot, Meeting Astm E648 Class 1 Radiant Panel Test.

Temporary Buildings Including Mobile
And Modular Facilities
20 Ounce Broadloom, Tufted, Commercial Grade, Loop Pile, Branded, Solution Dyed Nylon. Installation By Direct Glue Down.

Very High Traffic Areas
(Example: Medium To Heavy Use Public
Areas, Airports, College/University Food
Service Areas, Dormitories
20 Ounce Broadloom, Tufted, Structured Back, Commercial Grade, Nylon, Dupont Lumina or Legacy Or Basf 2000zx Yarn System. May Include High Density Urethane or Vinyl Chloride Pad Backing. Seams Should Be Capable of Sealing (Weld Together). Installation By Direct Glue Down

Page 1471 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 31

SAMPLE A
CONTRACTORS’ LICENSE REQUIREMENTS
The work described in this order requires a valid California Contractor’s License (C-15 Flooring and Floor Covering). If subcontractors are to be used, they must also possess valid State Contractors’ Licenses appropriate to their scope of work, and they must be listed below.

Supplier’s Contractor’s License Number:

License Issued to Whom:

Class / Type of License:

Expiration Date of License:

Work to be Performed:

Subcontractor’s Name and Address:

License Number:

Class / Type of License:

Expiration Date of License:

Work to be Performed:

WORKMEN’S COMPENSATION CERTIFICATION
The undersigned hereby certifies the following:

I am aware of the provisions of Section 3700 of the Labor Code which requires every employer to be insured against liability for workmen’s compensation or to undertake self-insurance in accordance with the provisions of that Code, and I will comply with such provisions before commencing the performance of the work of this order.

Signature of Supplier Date

Page 1472 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 32

SAMPLE B

PAYMENT BOND TO ACCOMPANY CONSTRUCTION CONTRACT
(Public Contract Code Sections 7103 and 10221)
BOND Number:

The premium on this bond is for the term
Know All Men By These Presents:

That The State of California, acting by and through the , has awarded to whose
address is as Principle, a contract
for the work described as follows:

Project Title:

Project Location:

WHEREAS, the provisions of Public Contract Code Section 7103 and 10221 require that the Principle file a bond in connection with said contract and this bond is executed and tendered in accordance therewith.

NOW THEREFORE, Principle and , a Surety
Corporation organized under the laws of and
authorized to transact a generalsurety business in the State of California, as Surety, are held and firmly bound to the People of the State of California in the penal sum of ( ), for which payment we bind ourselves, our
heirs, executors, administrators, successors and assigns jointly and severally, firmly by these presents.

Page 1473 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 33

SAMPLE B

THE CONDITION OF THIS OBLIGATION IS SUCH,

1. That if said Principle or its subcontractors shall fail to pay any of the persons named in Civil Code Section 9100, or amounts due under the Unemployment Insurance Code with respect to work or labor performed under the contract, or for any amounts required to be deducted, withheld, and paid over to the Employment Development Department from the wages of employees of the Principle and subcontractors pursuant to Section 13020 of the Unemployment Insurance Code, with respect to such work and labor, that the surety herein will pay for the same, otherwise this obligation is to be void. In case suit is brought upon this bond, the Surety will pay a reasonable attorney’s fee to be fixed by the court.

2. This bond shall insure to the benefit of any persons named in Civil Code Section 9100 as to give a right of action to such persons or their assigns in any suit brought upon this bond.

3. The aggregate liability of the Surety hereunder, including costs and attorney fees, on all claims whatsoever shall not exceed the penal sum of the bond in accordance with the provisions of Section 996.470(a) of the Code of Civil Procedure.

4. This bond is executed by the Surety, to comply with the provisions of Public Contract Code Sections 7103, 10221 and 10222, Chapter 5, Title 3, Part 6, Division 4 of the Civil Code and of Chapter 2, Title 14, Part 2 of the Code of Civil Procedure and said bond shall be subject to all of the terms and provisions thereof.

5. This bond may be cancelled by the Surety in accordance with the provisions of Section 996.310 et seq. of the Code of Civil Procedure.

6. This bond to become effective
(NAME OF SURETY) (ADDRESS)
I certify (or declare) under penalty of perjury that I have executed the foregoing bond under an unrevoked power of attorney.

Executed in on
(CITY AND STATE) (DATE)

(SIGNATURE OF ATTORNEY IN FACT) (PRINTED OR TYPED NAME OF ATTORNEY IN FACT)

STATE OF CALIFORNIA
STD. 807 (REV 2/14)

Page 1474 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 34

SAMPLE C

CARPET INSTALLATION REQUIREMENTS
Requirement Items
Required Yes
Items
Required
No
Performed By
Vendor
Performed By
Agency
Standard office furniture to be removed and replaced
(excluding copiers, computers, personal items and plants).

Vendor to provide all equipment and labor.

Remove existing:
carpet , pad , tile
Disposition: To State
Remove from State Premises
Raise and reset monuments.

Prepare floor and strip wax and other coatings and debris using commercial stripper. Follow stripper and carpet
manufacturer’s recommendations.

Remove trim, rehang doors and replace doorstops (except metal doors to be trimmed by State.

Inspection of floor preparation by Building Manager.

Reducer strips (metal , plastic ) to be installed in
accordance with the manufacturer’s recommendations and in accordance with approved broadloom seaming diagrams.

Tack strips to be installed.

Pad to be installed.

Page 1475 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 35 Requirement Items
Required Yes
Items
Required
No
Performed By
Vendor
Performed By
Agency
Cove base, rubber or vinyl
Furnish and install
Color: brown , black
other
Size: 6” , 4” , 2”
other
Remove existing base
Trim cove on existing base
Other (explain)

All spots and smears of floor adhesives and seam cement to be removed.

Remove all scraps and extraneous items from State premises upon completion of the installation and protect all adjacent areas from damage.

Leave overage with Building Manager.

Work to be performed on other than regular working hours.

Nights Weekends
Floor duct covers, contact:

Building Manager
Other

Page 1476 of 1646 ends

CALIFORNIA MULTIPLE AWARD SCHEDULE (CMAS)

KYA SERVICES, LLC
CMAS NUMBER 4-20-78-0089C, SUPPLEMENT NUMBER 7
December 18, 2024 Ordering Instructions and Special Provisions 36 SAMPLE C (continued)
Carpet Installation Instructions Continued

COORDINATION AND INSPECTION OF WORK
Site Inspection:

A job walk-through for the purpose of inspecting the installation site will be conducted on at at .

The walk-through inspection will be conducted by .

Failure to inspect the installation site in no way relieves the supplier from obligations as stated in this order.

Installation Coordination:
(Name) (Title)
at (Agency) , telephone ( )
will be responsible for coordination of all installation work. Within 10 days after receipt of a purchase order, the supplier shall contact (Name)
to coordinate an acceptable installation schedule.

No installation work shall commence without the Building Manager’s advance approval of the schedule.

Inspection of Installation Work:

Check here if any deficiencies in materials and/or workmanship are noted during inspection of the work in progress. The agency will immediately notify the supplier of these problems.

The supplier shall request an inspection after % of the work has been completed.

This inspection will be made jointly by the supplier and a designee of the agency. (Name) , (Title) ,
will be responsible for performing initial, continuing, and final inspection of the installation work by the supplier.

Page 1477 of 1646 ends

1 KYA Services, LLC
Contract Number:
47QSMA20D08P7

GENERALSERVICESADMINISTRATION
Federal Supply Service
Authorized FederalSupply SchedulePricelist
ScheduleTitle:MultipleAward
Schedule (MAS)
FSCGroup: B Facilities,B01FacilitiesMaintenanceandRepair,B03FacilitiesServices,B06Structures;C FurnitureandFurnishings,C09 FitnessSolutions,C01Flooring,C05MiscellaneousFurniture,C08Signs;J SecurityandProtection,J02ProtectiveEquipment,J05SecuritySystems;E IndustrialProductsand Services,E04HardwareandTools,E05IndustrialProducts;G Miscellaneous 06ComplimentarySINs.

FSCClass(es)/ProductCode(s) and/orServiceCodes:J035,7830,7220,5410,6260,4210,7110,4130,R799,3750,6210, 7810,6350,N099.

SIN: 561210SB: Smart Building Systems Integration
SIN:339920PARK:Park andPlaygroundEquipment. Furniture and Furnishings SIN:321918: Commercial Flooring
SIN:332311P:Pre-Engineeredand PrefabricatedBuildings and Structures SIN:334220: SurveillanceSystems
SIN: 335999: Power Distribution
SIN: 33712: Classroom Solutions
SIN:333415HVAC: Heating,Ventilation,Air Conditioning (HVAC) SIN:561210FAC: FacilitiesMaintenance andManagement
SIN: 333112: Lawn and Garden Equipment,Machinery, Implements, Tools SIN: 33512: Energy-Efficient Lighting and Sustainable Energy Solutions SIN: 339950: Signs
SIN: 334290 Security and Detection Systems
SIN: 334290L Physical Access Control Systems (PACS)
SIN: 238910 Installation and Site Preparation Services
SIN:OLM:Order-LevelMaterials(OLM)
SIN: 238160 RoofingProducts and Services Solutions
SIN: 339999F Flags,Banners, Pennants, and RelatedProducts SIN: 33411 Purchasing of New Electronic Equipment
Contract Number: 47QSMA20D08P7 Through Modification No: PS-0084 Contract Period: 02/11/2025–02/10/2030

ATTACHMENT D

Page 1478 of 1646 ends

2 Contractor: KYA Services, LLC
1800 East McFadden Avenue Santa Ana, CA 92705 www.thekyagroup.comt Business Size: Small Business
UEI Number: NNWJH8VLP55
Contract Administration Point of Contact: Edwin Jay – Sales Management Tel: 714-659-6478
Fax: 714-586-5526
[email protected]
On-line accessto contract ordering information, terms and conditions, up-to-date pricing, and the option to create an electronic delivery order are available through GSA Advantage!, a menu-driven database system. The INTERNET addressforGSAAdvantage!Is http://www.gsaadvantage.gov.Formore information on ordering from Federal Supply Schedules click on the FSS Schedules button at http://www.fss.gsa.gov.

Page 1479 of 1646 ends

CUSTOMERINFORMATION
1a. SpecialItemNumbers:
1b. Lowest Priced Item:
1c. LaborCategoryDescriptions:

2. Maximum Order:

3. MinimumOrder:

4. GeographicCoverage:

5. Pointof Production:
339920PARK,332311P,33712, 334220,321918, 33411
335999,333415HVAC,561210FAC,333112,33512,339950,
334290,334290L, 238910,561210SB,238160,339999F,OLM
Item GEOF1,WeedEnder$0.09
See pages 6 – 19.
$0
$0
Domestic Delivery:48 Contiguous States
KYA Services LLC.
1800E.McFaddenAve
Santa Ana, CA 92705

6. Discounts or Net Price: GSA Net Prices are shownon the attached GSA Pricelist.Negotiateddiscounthas beenappliedand
the IFF has been added.

7. Quantity Discounts: 2%over $500,000

8. Prompt PaymentTerms: 1% 20; Net30
*Information forOrderingOffices: Prompt paymentterms cannot be negotiatedout ofthe contractual agreement in exchange for other concessions.

9. ForeignItems: N/A
9b.Government PurchaseCard: Accepted abovethemicro-purchasethreshold. 10a. Timeof Delivery: Project dependent.
10b. Expedited Delivery None
10c. Overnightand2-day delivery Callforstock.
4

Page 1480 of 1646 ends

10d. Urgent Requirements Agencies can contactthe contractor’s Representativeto requestfasterdelivery.

11. F.O.B.: Origin, Freight PrepaidandAdd
12a. Ordering Address: KYA Services, LLC
1800E.McFaddenAve.

Santa Ana, CA 92705
12b. Ordering Procedures: For supplies and services,the ordering procedures, informationonBlanketPurchaseAgreements(BPA's)are
foundin FederalAcquisitionRegulation(FAR)8.405-3and
a sample BPA can be foundat the GSA/FSS Schedule
homepage (fss.gsa.gov/schedules)

13. Payment Address: KYA Services, LLC
1800E.McFaddenAve.

Santa Ana, CA 92705

14. WarrantyProvision: Manufacturer’sWarranty

15. ExportPackingCharges: NotApplicable

16. Terms andConditionsof Rental,Maintenance
andRepair: NotApplicable

17. Terms andConditionsofInstallation NotApplicable
18a. Terms and conditionsof repair NotApplicable
partsindicating date of parts price
listsandany discountsfrom list
prices.
18b.Terms&Conditionsforany otherservices: NotApplicable

19. Listofservice anddistributionpoints: Not Applicable

20. Listofparticipatingdealers: NotApplicable

21. Preventivemaintenance: NotApplicable
22a.SpecialAttributes: NotApplicable
22b. Section508 Compliance: NotApplicable

23. UniqueEntity Identifier(UEI)Number: NNWJHV8VLP55

24. NotificationRegardingRegistrationin SAM: Current
5

Page 1481 of 1646 ends

5 GSA Services Pricelist (including IFF)

TASK/JOB TITLE JOB

RESPONSIBILITY/DESCRIPTION

UOM GSAPRICE
incldg.

IFF

EDUCATION EXPERIENCE
Turf Removal Turf Removal SF 1.51 H.S 2 Years
Turf Application
(Standard) Turf Application (Standard) SF 5.32 H.S 2 Years Turf Application (NonStandard) Turf Application (Non-Standard) SF 7.1 H.S 2 Years Concrete Curb Concrete Curb LF 62.14 H.S 2 Years
Natural Sod Removal Natural Sod Removal SF 1.33 H.S 2 Years Poured-In-Place Removal Poured-In-Place Removal SF 4.44 H.S 2 Years Poured-In-Place
Application Poured-In-Place Application SF 14.21 H.S 2 Years Natural Sod Application Natural Sod Application SF 1.07 H.S 2 Years Poured-In-Place Repair Poured-In-Place Repair EA 923.22 H.S 2 Years Aggregate Base Removal Aggregate Base Removal SF 2.67 H.S 2 Years Aggregate Base
Application Aggregate Base Application SF 2.67 H.S 2 Years Logo Application Logo Application EA 12427.89 H.S 2 Years Track Surface Repair Track Surface Repair SY 133.16 H.S 2 Years Track Surface Re-Top Track Surface Re-Top SY 44.39 H.S 2 Years Track Surface Complete
Application
Track Surface Complete
Application SY 62.14 H.S 2 Years
Track Surface Refresh Track Surface Refresh SY 35.52 H.S 2 Years Structural Spray Black Structural Spray Black SF 4.61 H.S 2 Years Structural Spray Color Structural Spray Color SF 5.06 H.S 2 Years Base Mat w/ Structural
Spray Black
Base Mat w/ Structural Spray
Black SF 6.4 H.S 2 Years
Base Mat w/ Structural
Spray Color
Base Mat w/ Structural Spray
Color SF 6.83 H.S 2 Years
Polyurethane Sandwich
System Polyurethane Sandwich System SF 7.55 H.S 2 Years Polyurethane Full Pour Polyurethane Full Pour SF 11.98 H.S 2 Years Track Maintenance Track Maintenance LF 19529.54 H.S 4 Years Standard Floor
Preparation (So Cal)
Standard Floor Preparation (So
Cal) HRS 115.1 H.S 2 Years
Standard Floor
Preparation (Sac) Standard Floor Preparation (Sac) HRS 136.58 H.S 2 Years Standard Floor
Preparation (Bay Area)
Standard Floor Preparation (Bay
Area) HRS 175.71 H.S 2 Years
Excessive Floor
Preparation (So Cal)
Excessive Floor Preparation (So
Cal) HRS 115.1 H.S 2 Years
Excessive Floor
Preparation (Sac) Excessive Floor Preparation (Sac) HRS 136.58 H.S 2 Years Excessive Floor
Preparation (Bay Area)
Excessive Floor Preparation (Bay
Area) HRS 175.71 H.S 2 Years

Page 1482 of 1646 ends

6 Substrate Prep Substrate Prep SF 1.77 H.S 2 Years
Substrate Compaction Substrate Compaction SF 1.43 H.S 2 Years Trenching Trenching LF 46.16 H.S 2 Years
Clear, Grub and Haul Clear, Grub and Haul SF 3.1 H.S 2 Years Staking Staking LF 3.56 H.S 2 Years
Goal Post Application Goal Post Application LF 21304.95 H.S 4 Years Drainage Application Drainage Application LF 46.16 H.S 2 Years Application of Sports Pad Application of Sports Pad SF 1.77 H.S 2 Years Application of Playground
Pad Application of Playground Pad SF 1.77 H.S 2 Years
Application of Infill Application of Infill SF 0.53 H.S 2 Years Application of Header
board Application of Header board LF 6.21 H.S 2 Years
Removal of Existing
Surface Removal of Existing Surface SF 2.67 H.S 2 Years Application of Rubber
Playground Tiles
Application of Rubber
Playground Tiles SF 23.08 H.S 2 Years
Standard Synthetic Turf
Maintenance
Standard Synthetic Turf
Maintenance EA 9587.22 H.S 4 Years
Premium Synthetic Turf
Maintenance
Premium Synthetic Turf
Maintenance EA 13315.6 H.S 4 Years
Application of Asphalt Application of Asphalt SF 12.43 H.S 2 Years Application of Concrete Application of Concrete SF 44.39 H.S 2 Years Perimeter saw cut Perimeter saw cut LF 17.75 H.S 2 Years Application of tree wells Application of tree wells LF 13.32 H.S 2 Years Application of mulch Application of mulch SF 1.77 H.S 2 Years Application of
decomposed granite
Application of decomposed
granite SF 3.56 H.S 2 Years
Application of irrigation Application of irrigation LF 3.56 H.S 2 Years Perimeter pip removal Perimeter pip removal LF 7.1 H.S 2 Years Asphalt saw cut Asphalt saw cut LF 17.75 H.S 2 Years
Application of sealer Application of sealer SF 1.77 H.S 2 Years Re-grading base Re-grading base SF 2.67 H.S 2 Years
Field repairs Field repairs HRS 115.1 H.S 2 Years
Application of ramp Application of ramp SF 53.27 H.S 2 Years Application of replica
plants Application of replica plants EA 53.27 H.S 2 Years Application of cobble
stone Application of cobble stone SF 0.89 H.S 2 Years
application of woodchips application of woodchips SF 1.77 H.S 2 Years application of boulders application of boulders EA 621.39 H.S 2 Years application of slurry application of slurry SF 0.72 H.S 2 Years striping -asphalt striping -asphalt LF 2.22 H.S 2 Years natural tree - small natural tree - small EA 846.73 H.S 2 Years natural tree - med natural tree - med EA 1693.47 H.S 2 Years natural - large natural - large EA 2540.2 H.S 2 Years
application of natural
plants application of natural plants EA 42.33 H.S 2 Years

Page 1483 of 1646 ends