2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - NONRESIDENTIAL MANDATORY MEASURES UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT NONRESIDENTIAL MANDATORY MEASURES, SHEET 5 (July 2024)
Y N/A RESPON.
PARTY
Y N/A RESPON.
PARTY
Y N/A RESPON.
PARTY
Y N/A RESPON.
PARTY
SECTION 5.507 ENVIRONMENTAL COMFORT
5.507.4 ACOUSTICAL CONTROL. Employ building assemblies and components with Sound Transmission Class (STC) values determined in accordance with ASTM E 90 and ASTM E 413, or Outdoor-Indoor Sound Transmission Class (OITC) determined in accordance with ASTM E 1332, using either the prescriptive or performance method in Section 5.507.4.1 or 5.507.4.2.
Exception: Buildings with few or no occupants or where occupants are not likely to be affected by exterior noise, as determined by the enforcement authority, such as factories, stadiums, storage, enclosed parking structures and utility buildings.
Exception: [DSA-SS] For public schools and community colleges, the requirements of this section and all subsections apply only to new construction.
5.507.4.1 Exterior noise transmission, prescriptive method. Wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall meet a composite STC rating of at least 50 or a composite OITC rating of no less than 40, with exterior windows of a minimum STC of 40 or OITC of 30 in the following locations:
1. Within the 65 CNEL noise contour of an airport.
Exceptions:
1. Ldn or CNEL for military airports shall be determined by the facility Air Installation Compatible Land Use Zone (AICUZ) plan.
2. Ldn or CNEL for other airports and heliports for which a land use plan has not been developed shall be determined by the local general plan noise element.
2. Within the 65 CNEL or Ldn noise contour of a freeway or expressway, railroad, industrial source or fixed-guideway source as determined by the Noise Element of the General Plan.
5.507.4.1.1. Noise exposure where noise contours are not readily available. Buildings exposed to a noise level of 65 dB Leq - 1-hr during any hour of operation shall have building, addition or alteration exterior wall and roof-ceiling assemblies exposed to the noise source meeting a composite STC rating of at least 45 (or OITC 35), with exterior windows of a minimum STC of 40 (or OITC 30).
5.507.4.2 Performance Method. For buildings located as defined in Section 5.507.4.1 or 5.507.4.1.1, wall and roof-ceiling assemblies exposed to the noise source making up the building or addition envelope or altered envelope shall be constructed to provide an interior noise environment attributable to exterior sources that does not exceed an hourly equivalent noise level (Leq-1Hr) of 50 dBA in occupied areas during any hour of operation.
5.507.4.2.1 Site Features. Exterior features such as sound walls or earth berms may be utilized as appropriate to the building, addition or alteration project to mitigate sound migration to the interior.
5.507.4.2.2 Documentation of Compliance. An acoustical analysis documenting complying interior soundlevels shall be prepared by personnel approved by the architect or engineer of record.
5.507.4.3 Interior sound transmission. Wall and floor-ceiling assemblies separating tenant spaces and tenant spaces and public places shall have an STC of at least 40.
Note: Examples of assemblies and their various STC ratings may be found at the California Office of Noise Control: www.toolbase.org/PDF/CaseStudies/stc_icc_ratings.pdf.
SECTION 5.508 OUTDOOR AIR QUALITY
5.508.1 Ozone depletion and greenhouse gas reductions. Installations of HVAC, refrigeration and fire suppression equipment shall comply with Sections 5.508.1.1 and 5.508.1.2.
5.508.1.1 Chlorofluorocarbons (CFCs). Install HVAC, refrigeration and fire suppression equipment that do not contain CFCs.
5.508.1.2 Halons. Install HVAC, refrigeration and fire suppression equipment that do not contain Halons.
5.508.2 Supermarket refrigerant leak reduction. New commercial refrigeration systems shall comply with the provisions of this section when installed in retail food stores 8,000 square feet or more conditioned area, and that utilize either refrigerated display cases, or walk-in coolers or freezers connected to remote compressor units or condensing units. The leak reduction measures apply to refrigeration systems containing high-global-warming potential (high-GWP) refrigerants with a GWP of 150 or greater. New refrigeration systems include both new facilities and the replacement of existing refrigeration systems in existing facilities.
Exception: Refrigeration systems containing low-global warming potential (low-GWP) refrigerant with a GWP value less than 150 are not subject to this section. Low-GWP refrigerants are nonozone-depleting refrigerants that include ammonia, carbon dioxide (CO2), and potentially other refrigerants. 5.508.2.1 Refrigerant piping. Piping compliant with the California Mechanical Code shall be installed to be accessible for leak protection and repairs. Piping runs using threaded pipe, copper tubing with an outside diameter (OD) less than 1/4 inch, flared tubing connections and short radius elbows shall not be used in refrigerant systems except as noted below.
5.508.2.1.1 Threaded pipe. Threaded connections are permitted at the compressor rack.
5.508.2.1.2 Copper pipe. Copper tubing with an OD less than 1/4 inch may be used in systems with a refrigerant charge of 5 pounds or less.
5.508.2.1.2.1 Anchorage. One-fouth-inch OD tubing shall be securely clamped to a rigid base to keep vibration levels below 8 mils.
5.508.2.1.3 Flared tubing connections. Double-flared tubing connections may be used for pressure controls, valve pilot lines and oil.
Exception: Single-flared tubing connections may be used with a multiring seal coated with industrial sealant suitable for use with refrigerants and tightened in accordance with manufacturer's recommendations.
5.508.2.1.4 Elbows. Short radius elbows are only permitted where space limitations prohibit use of long radius elbows.
5.508.2.2 Valves. Valves Valves and fittings shall comply with the California Mechanical Code and as follows.
5.508.2.2.1 Pressure relief valves. For vessels containing high-GWP refrigerant, a rupture disc shall be installed between the outlet of the vessel and the inlet of the pressure relief valve.
5.508.2.2.1.1 Pressure detection. A pressure gauge, pressure transducer or other device shall be installed in the space between the rupture disc and the relief valve inlet to indicate a disc rupture or discharge of the relief valve.
5.508.2.2.2 Access valves. Only Schrader access valves with a brass or steel body are permitted for use.
5.508.2.2.2.1 Valve caps. For systems with a refrigerant charge of 5 pounds or more, valve caps shall be brass or steel and not plastic.
5.508.2.2.2.2 Seal caps. If designed for it, the cap shall have a neoprene O-ring in place.
5.508.2.2.2.2.1 Chain tethers. Chain tethers to fit ovr the stem are required for valves designed to have seal caps.
Exception: Valves with seal caps that are not removed from the valve during stem operation.
5.508.2.3 Refrigerated service cases. Refrigerated service cases holding food products containing vinegar and salt shall have evaporator coils of corrosion-resistant material, such as stainless steel; or be coated to prevent corrosion from these substances.
5.508.2.3.1 Coil coating. Consideration shall be given to the heat transfer efficiency of coil coating to maximize energy efficiency.
5.508.2.4 Refrigerant receivers. Refrigerant receivers with capacities greater than 200 pounds shall be fitted with a device tha indicates the level of refrigerant in the receiver.
5.508.2.6 Evacuation. The system shall be evacuated after pressure testing and prior to charging.
5.508.2.6.1 First vacuum. Pull a system vacuum down to at least 1000 microns (+/- 50 microns), and hold for 30 minutes.
5.508.2.6.2 Second vacuum. Pull a second system vacuum to a minimum of 500 microns and hold for 30 minutes.
5.508.2.6.3 Third vacuum. Pull a third vacuum down to a minimum of 300 microns, and hold for 24 hours with a maximum drift of 100 microns over a 24-hour period.
CHAPTER 7
INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS
702 QUALIFICATIONS
702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems.
Examples of acceptable HVAC training and certification programs include but are not limited to the following:
1. State certified apprenticeship programs.
2. Public utility training programs.
3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations.
4. Programs sponsored by manufacturing organizations.
5. Other programs acceptable to the enforcing agency.
702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector:
1. Certification by a national or regional green building program or standard publisher.
2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors.
3. Successful completion of a third party apprentice training program in the appropriate trade.
4. Other programs acceptable to the enforcing agency.
Notes:
1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code.
2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC-CG] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency.
Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS
703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist.
5.508.2.5 Pressure testing. The system shall be pressure tested during installation prior to evacuation and charging.
5.508.2.5.1 Minimum pressure. The system shall be charged with regulated dry nitrogen and appropriate tracer gas to bring system pressure up to 300 psig minimum.
5.508.2.5.2 Leaks. Check the system for leaks, repair any leaks, and retest for pressure using the same gauge.
5.508.2.5.3 Allowable pressure change. The system shall stand, unaltered, for 24 hours with no more than a +/- one pound pressure change from 300 psig, measured with the same gauge.
A0.8
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT NORTH
A1.0
- -
-1
Scale: N.T.S
SCOPE OF WORK CLASSIFICATION
MAP LEGEND
SCOPE OF WORK ; ADMINISTRATION BUILDING, MAINTENANCE
BUILDING, 311 BUILDING, FUEL ISLAND BUILDING
ADMIN.B ADMINISTRATION BUILDING A2.2
MAIN.B MAINTENANCE BUILDING A2.3
311.B 311 BUILDING A2.3
FUEL.B FUEL ISLAND BUILDING A2.3
ABBREVIATION BUILDING NAME SEE SHEET
ADMINISTRATION
BUILDING
SEE SHEET A2.2
MAINTENANCE
BUILDING
SEE SHEET A2.3
311
BUILDING
SEE SHEET A2.3
NORTH
AREA OF WORK
FUEL
ISLAND
BUILDING
SEE SHEET A2.3
MEN
WOMEN
VENDING
QUIET
WOMEN
MEN
CORR.
STORAGE
CLOSET
ASSIST.
TRANSIT
COORD
CONFERENCE
DISPATCH
TRANS.
SUPV.
TRANS.
MGR.
SECRETARY KITCHENET PANTRY
RECEPTION
LIFT
TRAINING ROOM
TRAINING ROOM
DRIVERS LOUNGE
VESRIBULE
DISPATCH
CORR.
CORR.
CORR.
LIFT
WAITING
ACCT.
SUPV.
ASSIST.
DIR.
SPECIAL
PLANNING
CORR.
OFFICE
CLERKS
CIRC.
AISLE
ELECT ROOM
MECH. SHAFT
MEN WOMEN
STAIR
ARCHIVES
1 A10.0 3'-0"
CONFERENCE
ROOM
CORR.
CORR.
AUDIT LOUNGE
ROOF
DECK
VEST.
ADMIN
SEC.
SPECIAL
COPY
WORK
EXERCISE ROOM
VESTIBULE
DEMOLITION PLAN NOTES
(E) WALLS TO DEMOLISH
DEMOLITION PLAN LEGEND
(E) WALLS TO REMAIN
SCOPE OF WORK
(E) TILE FLOORING TO REMOVE
(E) CARPET FLOORING TO REMOVE
(E) ITEMS TO DEMOLISH
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
ADMIN. BUILDING - DEMOLITION PLANS
A2.0
-3
Scale: 1/8" = 1'-0"
DEMOLITION PLAN - 2ND FLOOR
TRAINING ROOM
TRAINING ROOM
1. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING DESIGNATED DOORS AS INDICATED IN THE DEMOLITION PLAN. ENSURE ALL REMOVALS ARE PERFORMED WITHOUT DAMAGE TO ADJACENT STRUCTURES OR SURFACES TO REMAIN.
2. DEMOLISH AND PROPERLY DISPOSE OF ALL EXISTING WALLS INCLUDING WINDOWS, GLASS PARTITIONS AND MISCELLANEOUS DESIGNATED BY DASHED AND DOTTED LINES IN THE DEMOLITION PLANS. ENSURE
DEMOLITION IS EXECUTED WITHOUT DAMAGE TO ADJACENT STRUCTURES, FINISHES, OR UTILITIES TO REMAIN.
3. SAW CUT AND DEMOLISH EXISTING FLOORING AS INDICATED IN THE DEMOLITION PLAN. ENSURE NO DAMAGE TO ADJACENT STRUCTURES OR UTILITIES. PATCH AND REPAIR ALL AFFECTED AREAS TO
ACCOMMODATE NEW FLOORING PER FLOORING PLAN, FINISH SCHEDULE, AND CONSTRUCTION DOCUMENTS.
4. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING TILE & GRID AND GYPSUM BOARD CEILINGS,
INCLUDING ELECTRICAL FIXTURES, OUTLETS, AND ALL MISCELLANEOUS CEILING COMPONENTS AS INDICATED IN THE LIGHTING PLANS. ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING STRUCTURAL OR MEP ELEMENTS TO REMAIN.
5. REPLACE ALL CEILING-MOUNTED MECHANICAL INTAKE AND EXHAUST DUCT SCREENS WITH NEW AS SPECIFIED IN THE MECHANICAL PLANS. COORDINATE WITH MECHANICAL ENGINEERS TO ENSURE
PROPER DISCONNECTION, RELOCATION, AND RECONNECTION IN COMPLIANCE WITH ALL APPLICABLE CODES AND PROJECT REQUIREMENTS. ENSURE ALL WORK IS PERFORMED WITHOUT DISRUPTION TO ADJACENT SYSTEMS.
6. REMOVE AND PROPERLY DISPOSE OF ALL MILLWORKS INCLUDING UPPER AND BASE CABINETS, BUILT-IN STORAGE UNITS, PARTITIONS, SHELVES, AND COUNTERTOPS, AS INDICATED IN THE DEMOLITION PLAN.
ENSURE REMOVAL IS COMPLETED WITHOUT DAMAGE TO ADJACENT WALLS, FLOORS, OR UTILITIES TO REMAIN.
7. REMOVE AND LEGALLY DISPOSE OF EXISTING BUILT-IN MAILBOXES IN COMPLIANCE WITH ALL APPLICABLE LOCAL CODES AND REGULATIONS. ENSURE REMOVAL DOES NOT DAMAGE ADJACENT SURFACES OR STRUCTURAL ELEMENTS.
8. REMOVE ALL EXISTING KITCHEN EQUIPMENT AND MISCELLANEOUS ITEMS. SAFELY STORE IN A DESIGNATED AREA ON SITE AS CONFIRMED WITH CLIENT. ENSURE ALL PLUMBING CONNECTIONS ARE SHUT OFF AND PROPERLY CAPPED PRIOR TO DISCONNECTION.
9. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
3 1
1 1
1 1
3 3
3 3
3 3
3 3
3 3
3 4
4 4
4 4
4 4
4 4
4 4
4 6
6 6
6 6
6 7
2 2
2 2
2 2
2 2
2 2
2 2
2 2
2 1
6 2
2 2
3 4
5 NORTH
KEY MAP
6 8
7 NORTH
9 2
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE NOTES:
9 #
2 2
1 1
1 1
1 NOTES:
2. FOR ENTRANCE EXTERIOR STAIRS ENLARGEMENT PLANS, SEE SHEET A2.4. 3. FOR DIVERS LOUNGE AND DISPATCH ENLARGEMENT PLANS, SEE SHEET A3.0 - A3.3. 4. FOR FLOOR TRAINING ROOM ENLARGEMENT PLANS, SEE SHEETS A4.0 - A4.2. 5. FOR 1ST FLOOR CORRIDOR ENLARGEMENT PLAN, SEE SHEETS A5.0. 6. FOR ROOF DECK, LOUNGE, KITCHENETTE AND CORRIDOR ENLARGEMENT PLANS, SEE SHEETS A6.0 - A6.4. 7. FOR CONFERENCE ROOM ENLARGEMENT PLANS, SEE SHEETS A7.0 - A7.2. 8. FOR BREAK ROOM AND TRAINING ROOM ENLARGEMENT PLANS, SEE SHEET A8.0 - A8.2. 9. FOR BASEMENT RESTROOM ENLARGEMENT PLAN, SEE SHEET A10.0. 10. FOR 2ND FLOOR RESTROOM ENLARGEMENT PLAN, SEE SHEET A10.0.
NORTH
-2
Scale: 1/8" = 1'-0"
DEMOLITION PLAN - 1ST FLOOR -1
Scale: 1/8" = 1'-0"
RESTROOM DEMO. -BASEMENT
DEMO. RESTROOM PLAN NOTES
1. CAREFULLY DEMOLISH AND PROPERLY DISPOSE ALL EXISTING WALLS INDICATED BY DASHED LINES ON THE PLANS. PROTECT ADJACENT STRUCTURES, FINISHES, AND SURFACES DURING DEMOLITION ACTIVITIES TO AVOID DAMAGE.
2. CAREFULLY REMOVE ALL EXISTING DOORS, INCLUDING FRAMES AND HARDWARE. INSPECT
SURROUNDING WALL SURFACES FOR DAMAGE AND PATCH AS REQUIRED TO PREPARE FOR NEW
INSTALLATIONS IN ACCORDANCE WITH THE DOOR SCHEDULE AND ACCESSIBILITY CLEARANCE REQUIREMENTS. IF FEASIBLE AND UNDAMAGED DURING DEMOLITION, STORE REMOVED DOORS AND HARDWARE IN A SECURE LOCATION FOR POTENTIAL REUSE OR MODIFICATION.
3. REMOVE AND PROPERLY DISPOSE ALL EXISTING RESTROOM PARTITIONS, DOORS, HARDWARE, AND MISCELLANEOUS ITEMS.
4. DEMOLISH AND PROPERLY DISPOSE RESTROOM FLOORING TILE, MORTAR LAYERS DOWN TO THE EXISTING SLAB SURFACE. PATCH, REPAIR AND PREPARE SURFACE TO ENSURE A LEVEL SUBSTRATE FOR NEW TILE INSTALLATION, PER CONSTRUCTION PLAN AND FINISH SCHEDULE.
5. REMOVE AND PROPERLY DISPOSE ALL PLUMBING SYSTEM, PIPING AND PLUMBING FIXTURES, PER PLUMBING PLANS. ENSURE SHUT-OFF VALVES ARE CLOSED AND TAGGED BEFORE DISCONNECTION.
VERIFY PROPER SEALING OF DISCONNECTED PIPES TO AVOID LEAKS.
6. REMOVE AND PROPERLY DISPOSE ALL EXISTING TOILETS AND RESTROOM MISCELLANEOUS. CAP OFF ALL UTILITY CONNECTIONS AS REQUIRED, ENSURING SAFETY FOR SUBSEQUENT WORK.
7. REMOVE ALL EXISTING LIGHTING FIXTURES, WIRING, AND CONTROLS AS SPECIFIED IN ELECTRICAL PLANS. VERIFY AND TAG DISCONNECTED CIRCUITS TO ENSURE ELECTRICAL SAFETY DURING WORK.
8. DEMOLISH AND REMOVE ALL THE EXISTING TILES ON ALL WALL SURFACES. PATH, REPAIR AND PREPARE TO RECEIVE A NEW TILES PER FINISH SCHEDULE.
9. REMOVE AND REPLACE ALL EXISTING RESTROOM SIGNAGES WITH A NEW ONES. #
DEMOLITION KEY NOTES #
1. (E) BUILT- IN MAILBOXES - TO REMOVE
2. (E) FULL HEIGHT GLASS WALL TO DEMOLISH
3. (E) NOTICE BOARD - TO REMOVE
4. (E) TV - TO REMAIN
5. (E) CITY LOGO - TO REMAIN
6. (E) FIRE EXTINGUISHER
7. (E) SMALL PARCEL BOX - TO RELOCATE
8. (E) KEY CABINET LOCK - TO REPLACE WITH NEW
9. (E) FIRE EXTINGUISHER - TO RELOCATE
3 3
3 1
3 3
3 3
3 3
3 4
3 1
3 4
ADDITIONAL SCOPE OF FLOORING WORK
LOCKER
SHOWER
LOCKER
SHOWER
STAIRS
BREAK ROOM
MEN'S LOCKERS
MEN'S TOILET
WOMEN'S TOILET
1-2
A11.0
TRAINING ROOM
TOILET
CORR.
3 A11.0
12 Hall Area B
6 Hall Area A
4 5
3 Manager of St. Div Office Streets Supervisor General Staff Office Conference Room 10 Administrative Staff Area 21 OFFICE Office Admin EEOC 22 Kitchenette 13 16 Lunch Room 1 A12.0
3 A12.0
2 A12.0
4 A12.0
H=10'
3 A10.0
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-2
Scale: N.T.S
DEMOLITION PLAN - 2ND FLOOR - MAIN. BUILDING
MAINTENANCE & 311 BUILDING & FUEL
ISLAND - DEMOLITION PLANS
A2.1
-1
Scale: N.T.S
DEMOLITION PLAN - 1ST FLOOR - MAIN. BUILDING
MAIN. B. DEMO. PLAN NOTES
(E) WALLS TO DEMOLISH
DEMOLITION KEY NOTES
DEMOLITION PLAN LEGEND
(E) WALLS TO REMAIN
SCOPE OF WORK
(E) TILE FLOORING TO REMOVE
#
(E) ITEMS TO DEMOLISH
1. SAW CUT AND DEMOLISH EXISTING FLOORING AS INDICATED IN THE DEMOLITION PLAN. ENSURE NO DAMAGE TO ADJACENT STRUCTURES OR UTILITIES. PATCH AND REPAIR ALL AFFECTED AREAS TO ACCOMMODATE NEW FLOORING PER FLOORING PLAN, FINISH SCHEDULE, AND CONSTRUCTION DOCUMENTS.
2. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING GYPSUM BOARD CEILINGS, INCLUDING ELECTRICAL
FIXTURES, OUTLETS, AND ALL MISCELLANEOUS CEILING COMPONENTS AS INDICATED IN THE LIGHTING PLANS. ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING STRUCTURAL OR MEP ELEMENTS TO REMAIN.
3. REMOVE AND LEGALLY DISPOSE OF EXISTING PLENUM IN ITS ENTIRETY. ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING ADJACENT SYSTEMS, DUCTWORK, OR STRUCTURAL ELEMENTS TO REMAIN.
4. DEMOLISH AND PROPERLY DISPOSE OF THE WALL DESIGNATED BY DASHED AND DOTTED LINES IN THE DEMOLITION PLANS. ENSURE DEMOLITION IS EXECUTED WITHOUT DAMAGE TO ADJACENT STRUCTURES, FINISHES, OR UTILITIES TO REMAIN.
5. REPLACE ALL CEILING-MOUNTED MECHANICAL INTAKE AND EXHAUST DUCT SCREENS AS SPECIFIED IN THE MECHANICAL PLANS. COORDINATE WITH MECHANICAL ENGINEERS TO ENSURE PROPER DISCONNECTION,
RELOCATION, AND RECONNECTION IN COMPLIANCE WITH ALL APPLICABLE CODES AND PROJECT REQUIREMENTS. ENSURE ALL WORK IS PERFORMED WITHOUT DISRUPTION TO ADJACENT SYSTEMS.
6. REMOVE AND PROPERLY DISPOSE OF MILLWORKS INCLUDING UPPER AND BASE CABINETS, BUILT-IN STORAGE UNITS, SHELVES, AND COUNTERTOPS, AS INDICATED IN THE DEMOLITION PLAN. ENSURE REMOVAL IS COMPLETED WITHOUT DAMAGE TO ADJACENT WALLS, FLOORS, OR UTILITIES TO REMAIN.
7. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
8. REMOVE AND LEGALLY DISPOSE OF EXISTING ROLL-UP COUNTER DOOR IN ITS ENTIRETY.
ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING ADJACENT WALLS OR STRUCTURAL ELEMENTS TO REMAIN.
9. REMOVE ALL EXISTING KITCHEN EQUIPMENT AND MISCELLANEOUS ITEMS. SAFELY STORE IN A DESIGNATED AREA ON SITE AS CONFIRMED WITH CLIENT. ENSURE ALL PLUMBING CONNECTIONS ARE SHUT OFF AND PROPERLY CAPPED PRIOR TO DISCONNECTION.
10. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING DESIGNATED DOORS AS INDICATED IN THE DEMOLITION PLAN. ENSURE ALL REMOVALS ARE PERFORMED WITHOUT DAMAGE TO ADJACENT STRUCTURES OR SURFACES TO REMAIN.
1. (E) NOTICE BOARD - TO REPLACE
2. (E) NOTICE BOARD - TO REMOVE
3. (E) CEILING HEIGHT CHANGE LINE - TO REMAIN
4. (E) FIRE EXTINGUISHER
5. (E) KEY CABINET LOCK - TO REMOVE
6. (E) ROLL-UP DOOR - TO REMOVE
KEY MAP
MAIN. B. , 311 B. FUEL ISLAND RESTROOM
1. CAREFULLY DEMOLISH AND PROPERLY DISPOSE ALL EXISTING WALLS INDICATED BY DASHED LINES ON THE PLANS. PROTECT ADJACENT STRUCTURES, FINISHES, AND SURFACES DURING DEMOLITION ACTIVITIES TO AVOID DAMAGE.
2. CAREFULLY REMOVE ALL EXISTING DOORS, INCLUDING FRAMES AND HARDWARE. INSPECT SURROUNDING
WALL SURFACES FOR DAMAGE AND PATCH AS REQUIRED TO PREPARE FOR NEW INSTALLATIONS IN ACCORDANCE WITH THE DOOR SCHEDULE AND ACCESSIBILITY CLEARANCE REQUIREMENTS. IF FEASIBLE
AND UNDAMAGED DURING DEMOLITION, STORE REMOVED DOORS AND HARDWARE IN A SECURE LOCATION FOR POTENTIAL REUSE OR MODIFICATION.
3. REMOVE AND PROPERLY DISPOSE ALL EXISTING RESTROOM PARTITIONS, DOORS, HARDWARE, AND MISCELLANEOUS ITEMS.
4. DEMOLISH AND PROPERLY DISPOSE RESTROOM FLOORING TILE, MORTAR LAYERS DOWN TO THE EXISTING SLAB SURFACE. PATCH, REPAIR AND PREPARE SURFACE TO ENSURE A LEVEL SUBSTRATE FOR NEW TILE INSTALLATION, PER CONSTRUCTION PLAN AND FINISH SCHEDULE.
5. REMOVE AND PROPERLY DISPOSE ALL PLUMBING SYSTEM, PIPING AND PLUMBING FIXTURES, PER PLUMBING PLANS. ENSURE SHUT-OFF VALVES ARE CLOSED AND TAGGED BEFORE DISCONNECTION.
VERIFY PROPER SEALING OF DISCONNECTED PIPES TO AVOID LEAKS.
6. REMOVE AND PROPERLY DISPOSE ALL EXISTING TOILETS AND RESTROOM MISCELLANEOUS. CAP OFF ALL UTILITY CONNECTIONS AS REQUIRED, ENSURING SAFETY FOR SUBSEQUENT WORK.
7. REMOVE ALL EXISTING LIGHTING FIXTURES, WIRING, AND CONTROLS AS SPECIFIED IN ELECTRICAL PLANS.
VERIFY AND TAG DISCONNECTED CIRCUITS TO ENSURE ELECTRICAL SAFETY DURING WORK.
8. DEMOLISH AND REMOVE ALL THE EXISTING TILES ON ALL WALL SURFACES. PATH, REPAIR AND PREPARE TO RECEIVE A NEW TILES PER FINISH SCHEDULE.
9. REMOVE AND LEGALLY DISPOSE OF ALL EXISTING BUILT-IN LOCKERS IN THEIR ENTIRETY. ENSURE THAT ALL WORK IS PERFORMED WITHOUT DAMAGE TO ADJACENT SURFACES OR STRUCTURES.
10. CAREFULLY DETACH AND PROPERLY DISPOSE ANY MIRRORS, FIXTURES, OR OTHER OBJECTS ATTACHED TO THE WALL TO AVOID DAMAGE TO THE WALL SURFACE.
11. REMOVE AND REPLACE ALL EXISTING RESTROOM SIGNAGES WITH A NEW ONES. 1 2
1 2
1 2
3 (E) PLENUM TO REMOVE
6 9
6 6
4 8
1 2
3 2
3 4
6 5
1 2
2 2
6 9
9 6
NOTES:
NORTH
NORTH
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE #
#
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE 6 DEMO. PLAN NOTES
-3
Scale: N.T.S
DEMOLITION PLAN - 311 BUILDING
-4
Scale: N.T.S
DEMOLITION PLAN - FUEL ISLAND
NORTH
NORTH
4 10
8 ADDITIONAL SCOPE OF FLOORING WORK
(N)STORAGE DW Microwave Oven (E)PRINTER
(N)STORAGE
1 A2.4 X
1 A5.0 X
1 A3.0 X
DRIVERS
LOUNGE
VESTIBULE
DISPATCH
CORRIDOR
CORRIDOR
CORRIDOR
TRAINING
ROOM
TRAINING
ROOM
KITCHENETTE
1 A4.0
1 2
3 5
6 4
7 CORRIDOR
RECEPTION
VENDING
SINK
TV
TV
TV
ROOF
DECK
CORRIDOR
KITCHENETTE
LOUNGE
CONFERENCE
ROOM 1
A7.0
1 A6.1
2 A10.1
1 A6.3
COPY /
WORK
ACCT.
SUPV.
ASSIST.
DIR.
SPECIAL
PLANNING
ADMIN
SEC.
SPECIAL
WAITING
CLERKS
CIRC.
AISLE
CORR.
EXERCISE ROOM
VESTIBULE
ADMIN. B. CONST. PLAN NOTES
CONSTRUCTION PLAN LEGEND
(E)WALLS TO REMAIN
SCOPE OF WORK
(N) TILE FLOORING TO INSTALL
(N) CARPET FLOORING TO INSTALL
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
ADMIN BUILDING - CONSTRUCTION
PLANS
-2
Scale: 1/8" = 1'-0"
CONSTUCTION PLAN - 1ST FLOOR
A2.2
-3
Scale: 1/8" = 1'-0"
CONSTRUCTION PLAN - 2ND FLOOR
NOTES:
1. INSPECT ALL SPRINKLER SYSTEMS THROUGHOUT THE BUILDING. ENSURE ALL HEADS, PIPING, VALVES,
GAUGES, AND CONNECTIONS ARE IN GOOD WORKING CONDITION AND COMPLY WITH APPLICABLE FIRE SAFETY CODES. COORDINATE WITH FIRE MARSHAL OR AUTHORITY HAVING JURISDICTION (AHJ) IF REQUIRED. ENSURE SYSTEM IS FLUSHED, TESTED, AND CERTIFIED AFTER ANY MODIFICATIONS OR DISRUPTIONS TO SERVICE.
1. PATCH AND REPAIR EXISTING DAMAGED FLOORING SURFACES AS NECESSARY. ENSURE THE SUBSTRATE IS CLEAN, SMOOTH, AND PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH.
ALL REPAIRS SHALL RESULT IN A STABLE, LEVEL, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH CONSTRUCTION PLANS AND FINISH SCHEDULE, AND MANUFACTURER’S SPECIFICATIONS. ENSURE THAT THE INSTALLED FLOORING DOES NOT INTERFERE WITH THE OPERATION OF EXISTING DOORS.
ADDITIONAL SCOPE OF FLOORING WORK INCLUDES: RECEPTION, VENDING MACHINE ROOM, CLERKS, WAITING, ACCT. SUPV. , ASSIST. DIR. , TWO SPECIAL ROOMS, PLANNING ROOM, COPY/WORK ROOM.
2. CONSTRUCT ALL NEW INTERIOR DRY WALLS INCLUDING FULL HEIGHT GLASS PARTITIONS, SUPPORTED BY THE "SMART GLASS WHITEBOARD" SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS BY "INNOVATIVE GLASS" AND DRAWING ON SHEET "A4.7" INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS.
3. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, TILE AND GRID CEILING WITH ATTACHMENT OF ARMSTRONG IN ACCORDANCE WITH RCP. PLANS AND DETAILS RELATED TO EACH APPLICATIONS.
4. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS.
5. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY.
6. FURNISH AND INSTALL ALL MILLWORKS INCLUDING BUILT- IN STORAGE UNITS, UPPER AND BASE
CABINETS, SHELVING, AND PARTITIONS, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS.
7. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER
INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS.
8. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
9. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT FOR KITCHENETTE AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH
MECHANICAL ENGINEERS TO ENSURE THE PROPER DISCONNECTION, RELOCATION, AND
RECONNECTION OF EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY.
10. FURNISH AND INSTALL ALL NEW KITCHEN EQUIPMENT AND FINISHES AS SPECIFIED IN THE FIXTURE SCHEDULE AND WALL ELEVATIONS. ENSURE PROPER ALIGNMENT, CONNECTIONS, AND FUNCTIONALITY PER MANUFACTURER REQUIREMENTS AND PROJECT SPECIFICATIONS.
11. FURNISH AND INSTALL TILE AND GRID OR GYPSUM BOARD PER RCP PLANS, ENSURE ALL
CEILING HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
12. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
13. CONSTRUCT NEW CONCRETE ENTRANCE STAIRS IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AND DETAIL "5" ON SHEET "A2.2" CONSTRUCTION PLANS. FINISH SHALL BE POLISHED CONCRETE WITH NON-SLIP TREATMENT. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, SLOPE REQUIREMENTS.
14. FURNISH AND INSTALL NEW CABLE RAILING GUARDRAIL SYSTEM IN ACCORDANCE WITH "A2.4" CONSTRUCTION PLANS. 'VIEWRAIL' MANUFACTURER'S SPECIFICATIONS. ENSURE PROPER ANCHORAGE, ALIGNMENT, AND TENSIONING OF CABLES. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES AND SAFETY REQUIREMENTS.
15. FURNISH AND INSTALL WALL-MOUNTED GLASS WORKSTATION SHELF, WOOD-FRAMED IN ACCORDANCE WITH CONSTRUCTION PLAN, WALL VIEWS ON SHEET "A3.2" AND DETAILS ON SHEET "A3.3" CONSTRUCTION PLANS.
16. FURNISH AND INSTALL WOODEN SLIDING DOOR TO SERVE AS STORAGE ACCESS DOOR AND STRUCTURAL BACKING FOR WALL-MOUNTED TV, IN ACCORDANCE WITH "A4.0-A4.2" CONSTRUCTION PLANS AND "DAYORIS" MANUFACTURER SPECIFICATIONS.
17. FURNISH AND INSTALL VERTICAL ACOUSTIC FOLDING RETRACTABLE WALL. ENSURE THAT THE INSTALLATION COMPLIES FULLY WITH "A4.0-A4.2" CONSTRUCTION PLANS AND THE INSTALLATION COMPLIES FULLY WITH THE MANUFACTURER'S SPECIFICATIONS BY "SKYFOLD," INSTALLATION
CLEARANCES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND APPROVAL.
18. FURNISH AND INSTALL SINGLE LAYER TEXTILE ROOFING , IN ACCORDANCE WITH A6.0-A6.4 CONSTRUCTION PLANS AND "TENSION STRUCTURE" MANUFACTURER SPECIFICATIONS.
19. FURNISH AND INSTALL WOOD GRILL CEILING IN ACCORDANCE WITH THE CORRIDOR RCP ON "A5.0" CONSTRUCTION PLANS. ENSURE ALL INSTALLATIONS ARE SECURE, TIGHT, AND SAFE. ENSURE ALL
LIGHTING FIXTURES ARE INSTALLED IN ACCORDANCE WITH THE RCP ON THIS SHEET AND THE LOUNGE RCP "A5.0" CONSTRUCTION PLANS. VERIFY THAT ALL FIXTURES ARE FULLY FUNCTIONAL.
20. FURNISH AND INSTALL ROLL-UP COUNTER GRILLS IN ACCORDANCE WITH "A6.0-A6.4" CONSTRUCTION PLANS AND "INDUSTRIAL ROLL-UP DOORS" MANUFACTURE SPECIFICATIONS AND FRAMELESS FOLDING DOORS IN ACCORDANCE WITH A6.0-A6.4 PLANS AND"PREMIER FOLDING DOORS" MANUFACTURE SPECIFICATIONS.
21. FURNISH AND INSTALL NEW STRUCTURAL FRAME FOR RECEIVING MOSAIC GLASS SHEET ON THE EXISTING SQUARE GLASS BLOCK SYSTEM IN ACCORDANCE WITH DETAIL "4" AND ENLARGEMENT WALL VIEW ON SHEET "A6.3" CONSTRUCTION PLANS. FURNISH AND INSTALL SHEATHING PANELS OVER THE REMAINING SQUARE GLASS BLOCK AREAS AS INDICATED IN THE SAME DETAIL AND ENLARGED VIEW.
22. FURNISH AND INSTALL CEILING FEATURES AS FOLLOWS:
1. WOOD GRILL CEILING AT DISPATCH AREA PER DISPATCH RCP AND IN ACCORDANCE WITH MANUFACTURER "HUNTER DOUGLAS ARCHITECTURAL."
2. CEILING FEATURE AT CONJUNCTION AREA BETWEEN DRIVER'S LOUNGE AND FIRST FLOOR CORRIDOR, PER RELATED RCPs AND DETAIL 1 ON SHEET A3.3.
3. BRUSHED STEEL SHEET GRILL CEILING AT CONFERENCE ROOM PER CONFERENCE ROOM RCP, SECTIONS "5" AND "6", DETAIL 4 ON SHEET A7.0.
23. REPLACE ALL EXISTING FIBERGLASS SHEETS ON THE ROOF DECK CEILING. ENSURE NO DAMAGE IS CAUSED TO THE EXISTING CEILING STRUCTURE DURING REPLACEMENT. (N) TILE FLOORING
(N) CONCRETE EPOXY FLOORING TO INSTALL
(N) HARD WOOD FLOORING TO INSTALL
(N) NEW WALLS TO CONSTRUCT
1. FURNISH AND INSTALL ALL NEW INTERIOR DRY AND WET WALLS PER CONSTRUCTION PLAN. PATCH, REPAIR
AND PREPARE NEW AND DAMAGED SURFACES TO RECEIVE A NEW FINISH, ENSURE SEAMLESS TRANSITIONS AND HIGH-QUALITY WORKMANSHIP.
2. FURNISH AND INSTALL ALL NEW RESTROOM WALL TILES PER FINISH SCHEDULE AND CONSTRUCTION WALL VIEWS. ENSURE PROPER ALIGNMENT AND ADHERENCE TO SPECIFIED STANDARDS.
3. FURNISH AND INSTALL NEW FLOORING TILE AND FLOOR DRAINAGE, PER CONSTRUCTION PLAN AND FINISH SCHEDULE. ENSURE THE SUBSTRATE IS LEVEL AND PREPARED FOR THE TILE INSTALLATION.
4. FURNISH AND INSTALL ALL PLUMBING SYSTEM AND PIPING, PER PLUMBING PLANS. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, STANDARDS, AND PROJECT SPECIFICATIONS. COORDINATE WITH OTHER TRADES
AND DISCIPLINES TO AVOID CONFLICTS AND PROVIDE A FULLY FUNCTIONAL PLUMBING SYSTEM READY FOR TESTING AND COMMISSIONING.
5. FURNISH AND INSTALL ALL PLUMBING FIXTURES, PER FIXTURE SCHEDULE AND CONSTRUCTION PLANS.
CONDUCT THOROUGH TESTING TO ENSURE FUNCTIONALITY AND COMPLIANCE WITH LOCAL CODES.
6. FURNISH AND INSTALL ALL NEW TOILETS, RESTROOM MISCELLANEOUS AND MIRRORS PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. CONFIRM ALL INSTALLATIONS COMPLY WITH ADA ACCESSIBILITY STANDARDS, LOCAL BUILDING CODES, AND MANUFACTURER GUIDELINES.
7. FURNISH AND INSTALL RESTROOM PARTITIONS, DOORS, HARDWARE, AND ALL RELATED ACCESSORIES PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. ENSURE COMPLIANCE WITH ACCESSIBILITY
STANDARDS, DURABILITY REQUIREMENTS, AND PROPER ALIGNMENT
8. FURNISH AND INSTALL ALL LIGHTING FIXTURES, WIRING, AND CONTROLS PER RCP AND ELECTRICAL PLANS.
ENSURE PROPER OPERATION AND ADHERENCE TO SAFETY CODES.
9. REWORK ALL EXISTING DOORS AS REQUIRED TO COMPLY WITH PROJECT SPECIFICATIONS, ACCESSIBILITY STANDARDS, AND THE DOOR SCHEDULE. ADJUST, REPAIR, OR MODIFY DOORS, FRAMES, AND HARDWARE TO ENSURE PROPER FUNCTION, FIT, AND FINISH.
10. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL PAINT FINISH. PAINT ALL RESTROOM WALLS PER FINISH SCHEDULE UNLESS NOTED OTHERWISE. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
11. FURNISH AND INSTALL NEW ACCESSIBLE SIGN RESTROOM PER DETAILS 1 & 3 ON SHEET A0.2 .
12. FURNISH AND INSTALL LOCKERS WITH INTEGRATED DRAWER AND BENCH IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS FOR “FOREMAN ”. ENSURE PROPER ANCHORAGE, ALIGNMENT, AND FUNCTIONALITY UPON INSTALLATION. (NOT APPLY TO FUEL ISLAND AND ADMIN. B. RESTROOMS) NOTES:
2. FOR ENTRANCE EXTERIOR STAIRS ENLARGEMENT PLANS, SEE SHEET A2.4. 3. FOR DIVERS LOUNGE AND DISPATCH ENLARGEMENT PLANS, SEE SHEET A3.0 - A3.3. 4. FOR FLOOR TRAINING ROOM ENLARGEMENT PLANS, SEE SHEETS A4.0 - A4.2. 5. FOR 1ST FLOOR CORRIDOR ENLARGEMENT PLAN, SEE SHEETS A5.0. 6. FOR ROOF DECK, LOUNGE, KITCHENETTE AND CORRIDOR ENLARGEMENT PLANS, SEE SHEETS A6.0 - A6.4. 7. FOR CONFERENCE ROOM ENLARGEMENT PLANS, SEE SHEETS A7.0 - A7.2. 8. FOR BREAK ROOM AND TRAINING ROOM ENLARGEMENT PLANS, SEE SHEET A8.0 - A8.2. 9. FOR BASEMENT RESTROOM ENLARGEMENT PLAN, SEE SHEET A10.0. 10. FOR 2ND FLOOR RESTROOM ENLARGEMENT PLAN, SEE SHEET A10.0.
RESTROOM ADMIN. B. PLAN NOTES
NORTH NORTH
KEY MAP
-1
Scale: 1/8" - 1'-0"
RESTROOM CONST. - BASEMENT
NORTH
ADDITIONAL SCOPE OF FLOORING WORK
STAIRS
BREAK ROOM
1-2
A11.1
1 A8.0
TRAINING ROOM CORR.
3 A11.1
2 A8.0
12 Hall Area B
6 Hall Area A
4 5
3 Manager of St. Div Office Streets Supervisor General Staff Office Conference Room 10 Administrative Staff Area 21 OFFICE Office Admin EEOC 22 Kitchenette 13 16 Lunch Room 1 A12.1
3 A12.1
2 A12.1
4 A12.1
3 A10.1
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-2
Scale: 3/16" = 1'-0"
CONSTRUCTION PLAN - 2ND FLOOR - MA.B
MAINTENANCE & 311 BUILDING & FUEL
ISLAND - CONSTRUCTION PLANS
A2.3
-1
Scale: 3/16" = 1' -0"
CONSTRUCTION PLAN - 1ST FLOOR - MA.B
MAIN. B. CONST. PLAN NOTES
KEY MAP
MAIN. B. , 311 B. AND FUEL ISLAND
NORTH
NORTH
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE #
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE RESTROOMS CONST. PLAN NOTES
1. PATCH, AND REPAIR ALL DAMAGED FLOORING SURFACES AS NECESSARY. ENSURE THE SUBSTRATE IS PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL PROVIDE A SMOOTH, STABLE, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS.
2. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, CEILING IN ACCORDANCE WITH RCP PLANS.
3. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY.
4. FURNISH AND INSTALL ALL BUILT- IN STORAGE UNITS AND UPPER AND BASE CABINETS, SHELVING AND
COUNTERTOP, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS.
5. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER
INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS.
6. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
7. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT FOR KITCHENETTE AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH MECHANICAL
ENGINEERS TO ENSURE THE PROPER DISCONNECTION, RELOCATION, AND RECONNECTION OF EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY.
8. FURNISH AND INSTALL ALL NEW KITCHEN EQUIPMENT AS SPECIFIED IN THE FIXTURE SCHEDULE AND WALL VIEWS. ENSURE PROPER ALIGNMENT, CONNECTIONS, AND FUNCTIONALITY PER MANUFACTURER REQUIREMENTS AND PROJECT SPECIFICATIONS.
9. FURNISH AND INSTALL ALL TILE AND GRID PER CONSTRUCTION PLAN, ENSURE ALL CEILING
HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
10. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
NOTES:
1. INSPECT ALL SPRINKLER SYSTEMS THROUGHOUT THE BUILDING. ENSURE ALL HEADS, PIPING, VALVES,
GAUGES, AND CONNECTIONS ARE IN GOOD WORKING CONDITION AND COMPLY WITH APPLICABLE FIRE SAFETY CODES. COORDINATE WITH FIRE MARSHAL OR AUTHORITY HAVING JURISDICTION (AHJ) IF REQUIRED. ENSURE SYSTEM IS FLUSHED, TESTED, AND CERTIFIED AFTER ANY MODIFICATIONS OR DISRUPTIONS TO SERVICE.
1. FURNISH AND INSTALL ALL NEW INTERIOR DRY AND WET WALLS PER CONSTRUCTION PLAN. PATCH,
REPAIR AND PREPARE NEW AND DAMAGED SURFACES TO RECEIVE A NEW FINISH, ENSURE SEAMLESS TRANSITIONS AND HIGH-QUALITY WORKMANSHIP.
2. FURNISH AND INSTALL ALL NEW RESTROOM WALL TILES PER FINISH SCHEDULE AND CONSTRUCTION WALL VIEWS. ENSURE PROPER ALIGNMENT AND ADHERENCE TO SPECIFIED STANDARDS.
3. FURNISH AND INSTALL NEW FLOORING TILE AND FLOOR DRAINAGE, PER CONSTRUCTION PLAN AND FINISH SCHEDULE. ENSURE THE SUBSTRATE IS LEVEL AND PREPARED FOR THE TILE INSTALLATION.
4. FURNISH AND INSTALL ALL PLUMBING SYSTEM AND PIPING, PER PLUMBING PLANS. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, STANDARDS, AND PROJECT SPECIFICATIONS. COORDINATE WITH OTHER
TRADES AND DISCIPLINES TO AVOID CONFLICTS AND PROVIDE A FULLY FUNCTIONAL PLUMBING SYSTEM READY FOR TESTING AND COMMISSIONING.
5. FURNISH AND INSTALL ALL PLUMBING FIXTURES, PER FIXTURE SCHEDULE AND CONSTRUCTION PLANS.
CONDUCT THOROUGH TESTING TO ENSURE FUNCTIONALITY AND COMPLIANCE WITH LOCAL CODES.
6. FURNISH AND INSTALL ALL NEW TOILETS, RESTROOM MISCELLANEOUS AND MIRRORS PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. CONFIRM ALL INSTALLATIONS COMPLY WITH ADA ACCESSIBILITY STANDARDS, LOCAL BUILDING CODES, AND MANUFACTURER GUIDELINES.
7. FURNISH AND INSTALL RESTROOM PARTITIONS, DOORS, HARDWARE, AND ALL RELATED ACCESSORIES PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. ENSURE COMPLIANCE WITH
ACCESSIBILITY STANDARDS, DURABILITY REQUIREMENTS, AND PROPER ALIGNMENT
8. FURNISH AND INSTALL ALL LIGHTING FIXTURES, WIRING, AND CONTROLS PER RCP AND ELECTRICAL PLANS. ENSURE PROPER OPERATION AND ADHERENCE TO SAFETY CODES.
9. REWORK ALL EXISTING DOORS AS REQUIRED TO COMPLY WITH PROJECT SPECIFICATIONS, ACCESSIBILITY STANDARDS, AND THE DOOR SCHEDULE. ADJUST, REPAIR, OR MODIFY DOORS, FRAMES, AND HARDWARE TO ENSURE PROPER FUNCTION, FIT, AND FINISH.
10. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL PAINT FINISH. PAINT ALL RESTROOM WALLS PER FINISH SCHEDULE UNLESS NOTED OTHERWISE. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
11. FURNISH AND INSTALL LOCKERS WITH INTEGRATED DRAWER AND BENCH IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS FOR “FOREMAN ”. ENSURE PROPER ANCHORAGE, ALIGNMENT, AND FUNCTIONALITY UPON INSTALLATION. (NOT APPLY TO FUEL ISLAND AND ADMIN. B. RESTROOMS)
12. FURNISH AND INSTALL NEW ACCESSIBLE SIGN RESTROOM PER DETAILS 1 & 3 ON SHEET A0.2 .
13. FURNISH AND INSTALL NEW RESTROOM DOORS IN ACCORDANCE WITH THE DOOR SCHEDULE AND ARCHITECTURAL DRAWINGS. ENSURE ALL INSTALLATIONS MEET SPECIFIED DIMENSIONS, HARDWARE REQUIREMENTS, AND ADA COMPLIANCE.
-3
Scale: 1/8" - 1'-0"
RESTROOM CONSTRUCTION PLAN - 311 BUILDING
-4
Scale: 3/16" = 1' -0"
RESTROOM CONSTRUCTION PLAN - FUEL ISLAND
NORTH
NORTH
REMOVE ALL ATTACHMENTS AND MISCELLANEOUS ITEMS FROM EXISTING WALLS THAT MAY OBSTRUCT DEMOLITION OR REPAIRS. IF REQUESTED BY CLIENT, STORE
REMOVED ITEMS IN A PROPER AREA, BEFORE STARTING DEMOLITION PHASE
CONSTRUCTION PLAN LEGEND
(E)WALLS TO REMAIN
SCOPE OF WORK
(N) TILE FLOORING TO INSTALL
(N) CONCRETE EPOXY FLOORING TO INSTALL
(N) NEW WALLS TO CONSTRUCT
ADDITIONAL SCOPE OF FLOORING WORK
CABLE RAILING GUARDRAIL SYSTEM
1 2
3 4
5 6
7 90 % COMPACTED SUBSTRATE
CRUSHED STONE
BRUSH FINISHED CONCRETE
STEPS SLOPED TO DRAIN
+ 0'-0"
+ 4'-0"
KEEP 4' ACCESSIBLE
TURNING CLEARANCE
+ 0'-0"
+ 4'-0"
+ 5'-0"
+ 7'-6"
EXPANSION JOINT
REBAR DOWEL
CRUSHED STONE 7"
1' BRUSH FINISHED CONCRETE
STEPS SLOPED TO DRAIN
90 % COMPACTED SUBSTRATE
REBARS
REBAR IN.EACH
STEP NOSING
3/8" RADIUS
1 2
3 5
6 4
3 A2.2
7 3'-11"
6'-4"
3'-0" 130° 90°
141°
KEEP 4' ACCESSIBLE
TURNING CLEARANCE
90°
90°
6'-6" 3'-7"
6'-9"
2 A2.4
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-4
Scale: 1/4" = 1'-0"
ADMINISTRATION B. EXTERIOR STAIRS - ELEVATION
KEY PLAN
CONSTRUCTION PLAN NOTES #
NORTH
(E) WALLS TO DEMOLISH
PLAN LEGEND
(E) WALLS TO REMAIN
SCOPE OF WORK
(E),(N) CONCRETE FLOORING WITH EPOXY FINISH, U.N.O.
(E) ITEMS TO DEMOLISH
DEMOLITION PLAN NOTES #
1. DEMOLISH AND PROPERLY DISPOSE OF ALL EXISTING WALLS DESIGNATED BY DASHED AND DOTTED LINES IN THE DEMOLITION PLANS. ENSURE DEMOLITION IS EXECUTED WITHOUT DAMAGE TO ADJACENT STRUCTURES, FINISHES, OR UTILITIES TO REMAIN.
1. CONSTRUCT ALL NEW EXTERIOR CMU WALL WITH STUCCO FINISH, INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS.
2. CONSTRUCT NEW CONCRETE ENTRANCE STAIRS IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AND DETAIL "5" ON THIS SHEET. FINISH SHALL BE POLISHED CONCRETE WITH NON-SLIP TREATMENT. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, SLOPE REQUIREMENTS.
3. FURNISH AND INSTALL NEW CABLE RAILING GUARDRAIL SYSTEM IN ACCORDANCE WITH 'VIEWRAIL' MANUFACTURER'S SPECIFICATIONS. ENSURE PROPER ANCHORAGE, ALIGNMENT, AND TENSIONING OF CABLES. INSTALLATION SHALL COMPLY WITH ALL APPLICABLE BUILDING CODES AND SAFETY REQUIREMENTS.
4. REPAIR ALL LOOSE AND FLAKING PAINT FROM EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXTERIOR SURFACES ARE PROPERLY PAINTED AS REQUIRED. -2
Scale: 3/16" = 1'-0"
ADMINISTRATION B. EXTERIOR STAIRS - DEMOLITION PLAN
-3
Scale: 1/4" = 1'-0"
ADMINISTRATION B. EXTERIOR STAIRS - CONSTRUCTION PLAN
NORTH
NORTH
-1
Scale: 1/16" = 1'-0"
ADMINISTRATION B. EXTERIOR STAIRS - SITE PLAN
1 1
3 1
1. (N) MAIN BUILDING ENTRANCE - TO INSTALL
2. (E) ACCESSIBLE RAMP - TO REMAIN
3. (E) ENTRANCE STAIRS - TO REMAIN
4. (E) GUARD RAIL - TO REMAIN
5. (N) ENTRANCE STAIRS - TO CONSTRUCT
6. (N) GUARD RAIL - TO INSTALL
7. (N) FLOWER BOX, CMU STRUCTURE WITH STUCCO FINISH TO MATCH SURROUNDING COLOR - TO CONSTRUCT
8. (E) CANOPY ABOVE
9. (N) ENTRANCE RECESSED MAT - TO INSTALL
KEY LEGEND #
9 2
2 2
3 6
-5
Scale: 1/2" = 1'-0"
ADMINISTRATION B. EXTERIOR STAIRS - DETAIL
+ 4'-0"
+ 0'-0"
+ 0'-0"
+ 0'-0"
NORTH
(E) CMU WALL TO CONSTRUCT
1 1
1 2
3 3
3 4
DEMOLITION TO EXTEND UP TO THE STARTING
POINT OF THE ACCESSIBLE RAMP.
ALIGN
ALIGN
MAINTAIN A MINIMUM 4' SETBACK FROM THE
STARTING POINT OF THE ACCESSIBLE RAMP
DURING DEMOLITION TO ENSURE REQUIRED
TURNING CLEARANCE IS PRESERVED.
+ 4'-0"
7 7
5 2
7 4
8 8
8 1
START CONSTRUCTION
FROM THE EDGE OF THE
EXISTING WALL
START CONSTRUCTION
FROM THE EDGE OF THE
EXISTING WALL
6
6"
6" 3"
C.H.= 9'-0"
C.H.= 8'-9"
C.H.= 8'-6"
2'-0" 6" 2'-0" 6" 2'-0" 6" 2'-0" 6"
2"
+ 9'-6" 1" 3" 3" 3"
+ 8'-0"
C.H.= 8'-0"
EQ.
EQ.
EQ.
EQ.
C.H.= 8'-3" C.H.= 8'-3"
C.H.= 8'-10"
2'-0" 2" + 8'-10"
EQ.
EQ. 4
A5.0
2'-0" 6" 2'-0"
3 A3.3 6" 7" 5"
6" 6" 6" 1'-4" 10'-7" 1'-4" 6" 6" 6" 7" 5"
WOOD
GLASS
(N) WALL
WOOD
GLASS
(N) WALL
GLASS 2'-0" 1'-0" 5'-0" 9'-6" 1'-0" 6"
6" 6"
GLASS
WOOD
LINEAR LIGHT
RECESSED LIGHTS
WOOD
GLASS
GLASS
WALL
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/2" = 1'-0"
DRIVERS LOUNGE - CEILING DETAIL
-2
Scale: 1/2" = 1'-0"
WALL-MOUNTED GLASS WORKSTATION SHELF-DETAIL
A3.3
- -
-3
Scale: 1/2" = 1'-0"
WALL-MOUNTED GLASS WORKSTATION SHELF-DETAIL
KEY PLAN
ID NAME IMAGE MFG. / MODEL DIMENSIONS MATERIAL/FINISH
EQUIPMENT SCHEDULE
85" TV
MONITOR SAMSUNG, 85" Q80D QLED 4K 74.5" X 42.6" X 1.9" Google Smart TV with Alexa SMART TV WITH ALEXA COMPATIBILITY, QLED, 120HZ, DOLDY ATMOS, HDR10+, 360 AUDIO, HANDS FREE,
MOTION TECHNOLOGY
FINISH SCHEDULE
CONCRETE
FLOORING
ID NAME IMAGE MANUFACTURE MATERIAL COLOR
WALL
PAINT WP
REMARK
SIDE BY SIDE
BUILT-IN
REFRIGERATOR
PCRICHARD / FFRF36IFADA 31.5" x 35.5" x 24.25" (H x W x D) ADA compliant, commercially approved, frost-free, side-byside refrigerator-freezer for built-in use with
two panel ready doors, and front-placed digital controls
MONITOR
ARMS
Height range: 24.5” – 50”
Worksurface width: 42” – 84”
Worksurface depth: 24”, 30” , 36
ADJUSTABLE
SIT-STAND
TABLE
FRIANT / FCNAHBC
Corner C Leg Base
BEAM
PRIVACY
PANEL W: 36”, 42”, 48”, 54” 60”, 66”, 72" FRIANT / BEAM WITH FABRIC SCREEN
Designed to integrate with My-Hite tables for power and data distribution Manages cords cleanly in an open office environment without panels Post and Beam system has minimal parts, making it quick and easy to install Connect directly to power grommets or desk-mounted power units to optimize power options FRIANT / #FMA-D
3 Programmable height settings featured on a digital display Base accommodates work surfaces from 42” to 84” wide
Sturdy Aluminum Construction with 3 Stage Leg
Dual motors make for smooth adjustments
Combine with Beam for freestanding power and data management without panels Supports up to 19 lbs
Gas spring repositionable action
Detachable wire guides
Hardware included: grommet, clamp, and Verity track
MOUNT
MAILBOX
UNIT
NATIONALMAILBOXES / H155060RL Unit Size: 33-7/8″W x 41-7/8″H x 17″D Rear Loading Style (Open Backs)
Recessed, In-Wall Mount Only
Each private access mailbox tenant door is 6-3/8″W x 3″H Each unit has 5-pin cam lock with three keys
Each unit has a clear plastic window number slot for tenant identification
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
COUNTERTOP WILSONART
SHERWIN-WILLIAMS WATER-BASED
1 COAT PRIMER, 2 PAINT FINISH COAT TO ACHIEVE A FULL
COVERAGE
CEILING
PAINT CP
CT
SHERWIN-WILLIAMS PREMIUM CEILING PAINT WHITE
ACCESSIBLE BEIGE SW 7036
CUSTOM PANEL READY
SIDE COLOR : BLACK
OURO BRANCO - 5029K-22
UPPER
& BASE
CABINET
UB-C
CA CARPET MOHAWKGROUP
CONCRETECRAFT CONCRETE LIGHT GRAY POLISHED CONCRETE
577 SODALITE
PREMIUM LAMINATE
FENIXFORINTERIORS-NA BEIGE ARIZONA - J0748 MATTE SURFACE, ANTI FINGERPRINT - TV
RF
CF
AT
MA
BP
MM
LOCATION
THROUGHOUT
DRIVER'S
LOUNGE, U.N.O.
THROUGHOUT
ENTIRE BUILDING
WALLS, U.N.O.
THROUGHOUT
ENTIRE BUILDING
CEILING, U.N.O.
THROUGHOUT
DISPATCH, U.N.O.
THROUGHOUT
DISPATCH, U.N.O.
AS SHOWN IN
PLANS
PLYWOOD
DURACOLOR®
TRICOR PREMIUM
NYLON
TARR: HEAVY GSA STAIN RELEASE: PASS
FLAMMABILITY: ASTM E648: CLASS 1-GLUE DOWN
AATC 134: UNDER 3.5 KV ASTM E662: LESS THAN 450
WOOD GRILL
CEILING WG HUNTERDOUGLASARCHITECTURAL /
WOOD GRILL
AFRICAN AYOUS
Fully demonstrable system
Budget and design flexibility due to optimized program of panels GREENGUARD Gold Certificate Edgeband
GREENGUARD Gold Certificate RE-COVER™ Laminate
FSC Mixed Certificate for Laminate
Recycled Content - Laminate Types 335, 735
Recycled Content Laminate - Types 350, 376, 776
-4
Scale: N.T.S
FINISH SCHEDULE
NORTH
-5
Scale: N.T.S
EQUIPMENT SCHEDULE
FINISH
MATTE
EPOXY
EGGSHELL
FLAT
-
-
-
COLOR REMARK
AS SHOWN IN
PLANS SOLID WOOD WOOD
BLACK
1 COAT PRIMER, 2 PAINT FINISH COAT TO ACHIEVE A FULL
COVERAGE
-
-
-
-
-
-
1. ALL EQUIPMENT AND FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE CODES.
2. CONFIRM ALL EQUIPMENT LOCATIONS, CONNECTIONS, AND CLEARANCES WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS PRIOR TO INSTALLATION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT OR FINISHES.
4. ALL FINISHES TO BE INSTALLED WITH UNIFORM COLOR, TEXTURE, AND PATTERN ALIGNMENT, AS PER APPROVED SAMPLE.
5. ALL MATERIALS SHALL BE NEW, OF COMMERCIAL GRADE, AND FREE OF DEFECTS.
6. SUBMITTALS FOR ALL FINISHES AND EQUIPMENT SHALL BE PROVIDED FOR ARCHITECT’S REVIEW AND APPROVAL PRIOR TO PROCUREMENT.
7. WHERE FINISHES TRANSITION BETWEEN MATERIALS OR COLORS, PROVIDE CLEAN, STRAIGHT LINES AND FINISH EDGES USING MANUFACTURER’S STANDARD TRIM UNLESS NOTED OTHERWISE.
8. ENSURE ALL EQUIPMENT IS FULLY OPERATIONAL AND TESTED PRIOR TO FINAL INSPECTION.
REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.
EQUIPMENT AND FINISH GENERAL NOTES
ENTRANCE
RECESSED
MAT
RM C-SGROUP / PEDIMAT M1 AS SHOWN IN
PLANS
Pedimat M1
PET-G Rails & Aluminum
Hinge Connectors
CARPET/ALUMINUM GRAY -
TILE
FLOORING TF
TILE
FLOORING TF1
1ST FLOOR
CORRIDOR
RECEPTION
TILEMOSAICDIRECT
TILEMOSAICDIRECT
GLAZED
PORCELAIN
GLAZED
PORCELAIN
MATTE
LIGHT GRAY INSTALLATION
GRAY
MATTE
INSTALLATION DALTILE PERPETUO - 12"x12" SQUARE FLOOR TILE 24"x24" PORCELAIN TILE
WITH 6" RUBBER BASE
20'-4"
6" 6"
6'-0"
1'-6"
1'-0" 3'-11" 5'-8" 5'-9" 1'-4" 5'-9" 6" 1'-0" 13'-3" 1'-0" 6" 4'-3" 2'-7" 6" 1'-11" 5" 10'-7" 5"1'-11" 6'-3" 4'-3" 1'-9" 4'-8" 3'-8" 3'-4" 3'-8" 5" 9'-8" 2'-1"
DRIVERS' LOUNGE DISPATCH VESTIBULE
7'-6" 1'-9" 3'-2" 6'-8"
5"
5"
3'-0" 3'-0"
3'-0" 3'-0"
TYP.
TYP.
TYP.
1'-0"
4'-0" 2'-3"
2'-0" 8'-0" 2'-0" 2'-11" 5'-9" 3'-11"
1'-0" 4'-4" 2'-7" 2'-7"
5'-9" 3'-11" 16'-3" 3'-11" 5'-8" 7'-1"
42'-8" 9'-6"
85" 9'-6"
28'-0" 6'-2" 7" 6" 13'-6" 5'-0"
FIXED GLASS
5"
2 A3.3
1'-11" 2'-0" 1'-0" 5'-0" 1'-0" 6"
OPERATING GLASS 2'-10" 3'-6" 9'-6" 3'-2"
3'-0" 4'-3" 6" 5'-9" 3'-11"
42'-8" 6'-8" 2'-0" 1'-0" 5'-0" 9'-6" 1'-0" 6"
2'-9" 6" 1'-0" 13'-3" 1'-0" 4'-4"
GLASS
GRAY OAK WOOD
RECESSED LIGHTS
LED LINEAR LIGHT
RECESSED LIGHTS
85"
FIXED GLASS OPERATING GLASS
2 A3.3 2'-0" 1'-0" 5'-0" 1'-0" 6" LED LINEAR LIGHT
GRAY OAK WOOD
GRAY OAK WOOD
GLASS
GLASS
EXISTING WALL
A3.1
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/4" = 1'-0"
DRIVERS LOUNGE & DISPATCH DIMENSION PLAN
DIMENSION GENERAL NOTES
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
CONST. RCP PLAN NOTES
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL GYPSUM BOARD PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS,
MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. (AS NEEDED)
#
CF
CF
CF
CF
CA
CA
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A3.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
KEY PLAN
-2
Scale: 1/4" = 1'-0"
DRIVERS LOUNGE & DISPATCH WALL VIEW " A "
-3
Scale: 1/4" = 1'-0"
DRIVERS LOUNGE & DISPATCH WALL VIEW " B "
-4
Scale: 1/4" = 1'-0"
DRIVERS LOUNGE & DISPATCH WALL VIEW "C "
TV
TV
TV
MM
1 3
6 6
6 NORTH
A
B C
NORTH
(N) CONCRETE FLOORING
(N) CARPET FLOORING
CONSTRUCTION PLAN LEGEND
(E) WALLS TO REMAIN
AREA OF WORK
(E) WALLS TO DEMOLISH
(N) NEW WALLS TO CONSTRUCT
(E) TILE FLOORING
(N) FLOOR TRANSITION
(E) CARPET FLOORING
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A3.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
CONSTRUCTION KEY NOTES #
5 1
10 10
10 1. (N) WALL MOUNT MAIL BOX - SEE EQUIPMENT SCHEDULE ON SHEET A3.3
2. (N) GLASS GATE
3. (N) NOTICE BOARD - TO INSTALL
4. (E) TV - TO REMAIN
5. (E) CITY LOGO - TO REMAIN
6. (N) TV - TO INSTALL- SEE EQUIPMENT SCHEDULE ON SHEET A3.3
7. (N) PUSH-TO-EXIT BUTTON
8. (N) ADJUSTABLE SIT-STAND TABLE - SEE EQUIPMENT SCHEDULE ON SHEET A3.3
9. (N) BEAM WITH SCREEN - SEE EQUIPMENT SCHEDULE ON SHEET A3.3
10. (N) WALL-MOUNTED GLASS WORKSTATION SHELF, WOOD-FRAMED.
11. (E) PRINTER
12. (N) FIRE EXTINGUISHER
13. (E) SMALL PARCEL BOX - TO RELOCATE
14. (E) KEY CABINET LOCK - TO REPLACE WITH NEW
15. (E) SPACE FOR UPS CYBER POWER - TO RELOCATE
16. (E) WINDOW - TO REMAIN
17. (N) ENTRANCE RECESSED MAT - TO INSTALL
10
2'-10" 2'-10" 3'-11"
1'-1" 5" 3'-0" 9'-6" 4'-0" 2'-6" 9'-6"
2'-0" 9'-6" 3'-0" 4'-0" 2'-6" 9'-6"
3'-4" 20'-0" 2'-1" 2'-0"
25'-5" 2'-0" 4'-0" 2'-6" 5'-0" 1'-0" 9'-6" 9'-6" 6" 1'-0" 6" 6"
6" 6" EQ.
2 A3.3
FIXED GLASS OPERATING GLASS
5"
5" EQ. EQ. EQ. 3'-0" 5'-0"
GLASS DOOR
FILE
DRAWER
DRIVERS LOUNGE
DISPATCH
VESTIBULE
TV
TV
2 A3.3
TYP.
TYP.
TYP.
1'-0"
3 A3.3 9'-6" 3'-0" 2'-10"
3'-4" 2'-10" 3'-5" 2'-0" 9'-6" 4'-6"
EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. 3'-1" 5"
RECESSED LIGHTS
EQ. EQ.
GLASS
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-4
Scale: 3/8" = 1'-0"
DISPATCH WALL VIEW " D "
-5
Scale: 3/8" = 1'-0"
DISPATCH WALL VIEW " E "
-3
Scale: 3/8" = 1'-0"
DISPATCH WALL VIEW " F "
A3.2
- -
CONSTRUCTION KEY NOTES #
4 9
9 8
11 BP
AT
MA
TYP.
TYP.
TYP.
NORTH
KEY PLAN
D
F
E G
-2
Scale: 1/4" = 1'-0"
DISPATCH WALL VIEW " G "
-1
Scale: 3/16" = 1'-0"
DRIVERS' LOUNGE & DISPATCH WALL VIEWS GUIDE
CT CT CT
UB-C RF
UB-C
MM
MM
UB-C
UB-C
CT
NORTH
4 (N) CONCRETE FLOORING
(N) CARPET FLOORING
CONSTRUCTION PLAN LEGEND
(E) WALLS TO REMAIN
AREA OF WORK
(E) WALLS TO DEMOLISH
(N) NEW WALLS TO INSTALL
(E) TILE FLOORING
(N) FLOOR TRANSITION
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A3.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
10 16
16 1
12 NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A3.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
1. (N) WALL MOUNT MAIL BOX - SEE EQUIPMENT SCHEDULE ON SHEET A3.3
2. (N) GLASS GATE
3. (N) NOTICE BOARD - TO INSTALL
4. (E) TV - TO REMAIN
5. (E) CITY LOGO - TO REMAIN
6. (N) TV - TO INSTALL- SEE EQUIPMENT SCHEDULE ON SHEET A3.3
7. (N) PUSH-TO-EXIT BUTTON
8. (N) ADJUSTABLE SIT-STAND TABLE - SEE EQUIPMENT SCHEDULE ON SHEET A3.3
9. (N) BEAM WITH SCREEN - SEE EQUIPMENT SCHEDULE ON SHEET A3.3
10. (N) WALL-MOUNTED GLASS WORKSTATION SHELF, WOOD-FRAMED.
11. (E) PRINTER
12. (N) FIRE EXTINGUISHER
13. (E) SMALL PARCEL BOX - TO RELOCATE
14. (E) KEY CABINET LOCK - TO REPLACE WITH NEW
15. (E) SPACE FOR UPS CYBER POWER - TO RELOCATE
16. (E) WINDOW - TO REMAIN
TYP.
TYP. 9
6 1
8 3
6 6
5 10
2 11
12 13
14 15
7 4 4
3 1
9 8
9 8
14 8
2
6"
6" 3"
C.H.= 9'-0"
C.H.= 8'-9"
C.H.= 8'-6"
2'-0" 6" 2'-0" 6" 2'-0" 6" 2'-0" 6"
2"
+ 9'-6" 1" 3" 3" 3"
+ 8'-0"
C.H.= 8'-0"
EQ.
EQ.
EQ.
EQ.
C.H.= 8'-3" C.H.= 8'-3"
C.H.= 8'-10"
2'-0" 2" + 8'-10"
EQ.
EQ. 4
A5.0
2'-0" 6" 2'-0"
3 A3.3 6" 7" 5"
6" 6" 6" 1'-4" 10'-7" 1'-4" 6" 6" 6" 7" 5"
WOOD
GLASS
(N) WALL
WOOD
GLASS
(N) WALL
GLASS 2'-0" 1'-0" 5'-0" 9'-6" 1'-0" 6"
6" 6"
GLASS
WOOD
LINEAR LIGHT
RECESSED LIGHTS
WOOD
GLASS
GLASS
WALL
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/2" = 1'-0"
DRIVERS LOUNGE - CEILING DETAIL
-2
Scale: 1/2" = 1'-0"
WALL-MOUNTED GLASS WORKSTATION SHELF-DETAIL
A3.3
- -
-3
Scale: 1/2" = 1'-0"
WALL-MOUNTED GLASS WORKSTATION SHELF-DETAIL
KEY PLAN
ID NAME IMAGE MFG. / MODEL DIMENSIONS MATERIAL/FINISH
EQUIPMENT SCHEDULE
85" TV
MONITOR SAMSUNG, 85" Q80D QLED 4K 74.5" X 42.6" X 1.9" Google Smart TV with Alexa SMART TV WITH ALEXA COMPATIBILITY, QLED, 120HZ, DOLDY ATMOS, HDR10+, 360 AUDIO, HANDS FREE,
MOTION TECHNOLOGY
FINISH SCHEDULE
CONCRETE
FLOORING
ID NAME IMAGE MANUFACTURE MATERIAL COLOR
WALL
PAINT WP
REMARK
SIDE BY SIDE
BUILT-IN
REFRIGERATOR
PCRICHARD / FFRF36IFADA 31.5" x 35.5" x 24.25" (H x W x D) ADA compliant, commercially approved, frost-free, side-byside refrigerator-freezer for built-in use with
two panel ready doors, and front-placed digital controls
MONITOR
ARMS
Height range: 24.5” – 50”
Worksurface width: 42” – 84”
Worksurface depth: 24”, 30” , 36
ADJUSTABLE
SIT-STAND
TABLE
FRIANT / FCNAHBC
Corner C Leg Base
BEAM
PRIVACY
PANEL W: 36”, 42”, 48”, 54” 60”, 66”, 72" FRIANT / BEAM WITH FABRIC SCREEN
Designed to integrate with My-Hite tables for power and data distribution Manages cords cleanly in an open office environment without panels Post and Beam system has minimal parts, making it quick and easy to install Connect directly to power grommets or desk-mounted power units to optimize power options FRIANT / #FMA-D
3 Programmable height settings featured on a digital display Base accommodates work surfaces from 42” to 84” wide
Sturdy Aluminum Construction with 3 Stage Leg
Dual motors make for smooth adjustments
Combine with Beam for freestanding power and data management without panels Supports up to 19 lbs
Gas spring repositionable action
Detachable wire guides
Hardware included: grommet, clamp, and Verity track
MOUNT
MAILBOX
UNIT
NATIONALMAILBOXES / H155060RL Unit Size: 33-7/8″W x 41-7/8″H x 17″D Rear Loading Style (Open Backs)
Recessed, In-Wall Mount Only
Each private access mailbox tenant door is 6-3/8″W x 3″H Each unit has 5-pin cam lock with three keys
Each unit has a clear plastic window number slot for tenant identification
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
COUNTERTOP WILSONART
SHERWIN-WILLIAMS WATER-BASED
1 COAT PRIMER, 2 PAINT FINISH COAT TO ACHIEVE A FULL
COVERAGE
CEILING
PAINT CP
CT
SHERWIN-WILLIAMS PREMIUM CEILING PAINT WHITE
ACCESSIBLE BEIGE SW 7036
CUSTOM PANEL READY
SIDE COLOR : BLACK
OURO BRANCO - 5029K-22
UPPER
& BASE
CABINET
UB-C
CA CARPET MOHAWKGROUP
CONCRETECRAFT CONCRETE LIGHT GRAY POLISHED CONCRETE
577 SODALITE
PREMIUM LAMINATE
FENIXFORINTERIORS-NA BEIGE ARIZONA - J0748 MATTE SURFACE, ANTI FINGERPRINT - TV
RF
CF
AT
MA
BP
MM
LOCATION
THROUGHOUT
DRIVER'S
LOUNGE, U.N.O.
THROUGHOUT
ENTIRE BUILDING
WALLS, U.N.O.
THROUGHOUT
ENTIRE BUILDING
CEILING, U.N.O.
THROUGHOUT
DISPATCH, U.N.O.
THROUGHOUT
DISPATCH, U.N.O.
AS SHOWN IN
PLANS
PLYWOOD
DURACOLOR®
TRICOR PREMIUM
NYLON
TARR: HEAVY GSA STAIN RELEASE: PASS
FLAMMABILITY: ASTM E648: CLASS 1-GLUE DOWN
AATC 134: UNDER 3.5 KV ASTM E662: LESS THAN 450
WOOD GRILL
CEILING WG HUNTERDOUGLASARCHITECTURAL /
WOOD GRILL
AFRICAN AYOUS
Fully demonstrable system
Budget and design flexibility due to optimized program of panels GREENGUARD Gold Certificate Edgeband
GREENGUARD Gold Certificate RE-COVER™ Laminate
FSC Mixed Certificate for Laminate
Recycled Content - Laminate Types 335, 735
Recycled Content Laminate - Types 350, 376, 776
- FINISH SCHEDULE 4
NORTH
- EQUIPMENT SCHEDULE 5
FINISH
MATTE
EPOXY
EGGSHELL
FLAT
-
-
-
COLOR REMARK
AS SHOWN IN
PLANS SOLID WOOD WOOD
BLACK
1 COAT PRIMER, 2 PAINT FINISH COAT TO ACHIEVE A FULL
COVERAGE
-
-
-
-
-
-
1. ALL EQUIPMENT AND FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE CODES.
2. CONFIRM ALL EQUIPMENT LOCATIONS, CONNECTIONS, AND CLEARANCES WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS PRIOR TO INSTALLATION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT OR FINISHES.
4. ALL FINISHES TO BE INSTALLED WITH UNIFORM COLOR, TEXTURE, AND PATTERN ALIGNMENT, AS PER APPROVED SAMPLE.
5. ALL MATERIALS SHALL BE NEW, OF COMMERCIAL GRADE, AND FREE OF DEFECTS.
6. SUBMITTALS FOR ALL FINISHES AND EQUIPMENT SHALL BE PROVIDED FOR ARCHITECT’S REVIEW AND APPROVAL PRIOR TO PROCUREMENT.
7. WHERE FINISHES TRANSITION BETWEEN MATERIALS OR COLORS, PROVIDE CLEAN, STRAIGHT LINES AND FINISH EDGES USING MANUFACTURER’S STANDARD TRIM UNLESS NOTED OTHERWISE.
8. ENSURE ALL EQUIPMENT IS FULLY OPERATIONAL AND TESTED PRIOR TO FINAL INSPECTION.
REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.
EQUIPMENT AND FINISH GENERAL NOTES
ENTRANCE
RECESSED
MAT
RM C-SGROUP / PEDIMAT M1 AS SHOWN IN
PLANS
Pedimat M1
PET-G Rails & Aluminum
Hinge Connectors
CARPET/ALUMINUM GRAY -
TILE
FLOORING TF
TILE
FLOORING TF1
1ST FLOOR
CORRIDOR
RECEPTION
TILEMOSAICDIRECT
TILEMOSAICDIRECT
GLAZED
PORCELAIN
GLAZED
PORCELAIN
MATTE
LIGHT GRAY INSTALLATION
GRAY
MATTE
INSTALLATION DALTILE PERPETUO - 12"x12" SQUARE FLOOR TILE 24"x24" PORCELAIN TILE
WITH 6" RUBBER BASE
C.H.= 8'-06" C.H.= 9'-11"
C.H.= 9'-11"
C.H.= 9'-11"
4" 3'-2" 4'-0" 2'-6" 5'-1" 7" 4'-0" 4'-0" 4'-0"
C.H.= 9'-11"
2'-11" 4'-0" 4'-0" 5'-2" 1'-0" 1'-0"
5'-11" 5'-11"
3'-11" 2'-9"3'-11" 4'-0" 2'-9" 3'-2"
4'-0" 1'-9"
(E)PRINTER
(N)STORAGE
TRAINING ROOM TRAINING ROOM
(E)STORAGE
TV
TV
1 A2.1
3 A4.1
4 A4.1
65" 65"
5'-11" 8'-0" 1'-5" 9'-11" 6"6'-3" 5'-11" 6'-0" 6' 4'-0" SLIDING DOOR SLIDING DOOR SLIDING DOOR 4'-0" 4'-0" 4'-0"SLIDING DOOR A4.0
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-3
Scale: 3/16" = 1'-0"
TRAINING ROOM - REFLECTED CEILING PLAN
CONSTRUCTION PLAN LEGEND
C.H.= # - # CEILING HEIGHT
TRAINING ROOM CONSTRUCTION, RCP &
WALL VIEWS 1ST FLOOR|ADMIN BUILDING
KEY PLAN
-1
Scale: 3/16" = 1'-0"
TRAINING ROOM - CONSTRUCTION PLAN
(N) FLOOR TRANSITION
(E) WALLS TO REMAIN
AREA OF WORK
(N) NEW WALLS TO CONSTRUCT
(N) DOOR SCHEDULE
(N) CONCRETE EPOXY FLOORING
(N) RECESSED LED 2'X4' LIGHTING
(E) TILE FLOORING TO REMOVE
1. PATCH, AND REPAIR ALL DAMAGED FLOORING SURFACES AS NECESSARY. ENSURE THE SUBSTRATE IS PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL PROVIDE A SMOOTH, STABLE, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS.
2. CONSTRUCT ALL NEW INTERIOR DRY WALLS INCLUDING WINDOWS AND FULL HEIGHT GLASS PARTITIONS AS INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS.
3. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, CEILING IN ACCORDANCE WITH RCP PLANS.
4. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS.
5. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY.
6. FURNISH AND INSTALL ALL BUILT- IN STORAGE UNITS, SHELVING AND COUNTERTOP, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS.
7. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER
INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS.
8. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
9. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT FOR KITCHENETTE AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH MECHANICAL ENGINEERS TO
ENSURE THE PROPER DISCONNECTION, RELOCATION, AND RECONNECTION OF EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY.
10. FURNISH AND INSTALL ALL NEW KITCHEN EQUIPMENT AS SPECIFIED IN THE FIXTURE SCHEDULE AND WALL ELEVATIONS. ENSURE PROPER ALIGNMENT, CONNECTIONS, AND FUNCTIONALITY PER MANUFACTURER REQUIREMENTS AND PROJECT SPECIFICATIONS.
11. FURNISH AND INSTALL WOODEN SLIDING DOOR TO SERVE AS STORAGE ACCESS DOOR AND STRUCTURAL BACKING FOR WALL-MOUNTED TV, IN ACCORDANCE WITH "DAYORIS" MANUFACTURER SPECIFICATIONS.
12. FURNISH AND INSTALL VERTICAL ACOUSTIC FOLDING RETRACTABLE WALL. ENSURE THAT THE INSTALLATION COMPLIES FULLY WITH THE MANUFACTURER'S SPECIFICATIONS BY "SKYFOLD,"
INSTALLATION CLEARANCES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND APPROVAL.
CONSTRUCTION PLAN NOTES #
CONSTRUCTION KEY NOTES #
1. (N) SPACE FOR VERTICAL ACOUSTIC FOLDING RETRACTABLE WALL
2. (N) WOODEN SLIDING DOOR
3. (N) WALL-MOUNTED TV
4. (E) PLENUM
5. (N) SPACE FOR DISHWASHER
6. (N) SPACE FOR MICROWAVE AND OVEN
7. (N) FULL-HEIGHT KITCHEN STORAGE CABINET
8. (E) CEILING HEIGHT CHANGE LINE
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A4.2
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
B
A
C
1 3
2 6
2 1
3 1
3 2
2 2
2 2
4 4
4 4
CONST. RCP PLAN NOTES
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL TILE AND GRID PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS,
MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. (AS NEEDED)
#
11 11
12 NORTH
1 1
2 2
3 3
7 6 5
8 8
8 ALIGN
ALIGN
ALIGN ALIGN ALIGN ALIGN ALIGN
-2
Scale: 1/2" = 1'-0"
TRAINING ROOM - WALL VIEW "A"
1 2 2 2 2
3 3
4 VW
WP
CP
CP
CP
CF CF
WP WP
CP
EQ.
REFRIGERATOR
EQ.
EQ. EQ. EQ. EQ.
2'-0"
2'-0"
2'-6"
2'-6" 7'-1" 1'-9" 1'-1" 1'-1" 3'-10" 2'-0" 3'-0" 9'-11"
SPACE FOR
DISH WASHER
EQ. 2'-1" EQ. EQ. 2'-6" 2'-8"
15'-9"
2'-0" 3'-0" 2'-0" 3'-10" 1'-1" 9'-11" 8'-10" 1'-1"9" 1'-6" 1'-8" 3'-4" 3'-10" 15'-9" 2'-0" 7'-6" 4" 4'-0" 5"
6'-2" 3'-6" 6'-1"
4"
3'-1" 8'-10" 3'-2" 4"
3'-0" 2'-8" 3'-1" 2'-6" 2'-6" 2'-0" 4" 3'-2"
TV
TV
5'-3" 3'-8"
15'-9" 2'-0" 7'-6" 4'-0" 5"
6'-2" 3'-6" 6'-1"
6'-0" 6'-0" 6'-0" 6'-0" 6'-0"
7'-9"
4" 3'-1" 8'-10" 3'-2" 4"
3'-0" 2'-8" 3'-1" 2'-6" 2'-6" 2'-0" 2'-0" 4" 3'-2" 1'-2" 5"
(E)PRINTER
(N)STORAGE
TRAINING ROOM TRAINING ROOM
(E)STORAGE
2'-7" 4" 3
A4.1
4 A4.1
2 A4.1
TV
(E)STORAGE
6'-0" 6'-0"
FIXED SIDE
OPERABLE SIDE
OPERABLE SIDE
BOARD
TV
(N)STORAGE
OPERABLE SIDE
OPERABLE SIDE
OPERABLE SIDE
6'-0" 6'-0" 6'-0"
OPERABLE SIDE
BOARD
A4.1
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-6
Scale: 1/2" = 1'-0"
TRAINING ROOM KITCHEN - WALL VIEW "A"
-2
Scale: 1/2" = 1'-0"
TRAINING ROOM CONSTRUCTION - KITCHEN PLAN ENLARGEMENT
CONSTRUCTION PLAN LEGEND
-5
Scale: 1/2" = 1'-0"
TRAINING ROOM - KITCHEN WALL VIEW "B"
B
A
-1
Scale: 3/16" = 1'-0"
TRAINING ROOM - DIMENSION PLAN
(E) WALLS TO REMAIN
AREA OF WORK
(N) NEW WALLS TO INSTALL
(N) DOOR SCHEDULE
1 3
2 2
2 4 4
4 6 6
6 CONSTRUCTION KEY NOTES #
1. (N)VERTICAL ACOUSTIC FOLDING RETRACTABLE WALL
2. (N) WOODEN SLIDING DOOR
3. (N) WALL-MOUNTED TV
4. (E) PRINTER
5. (N) SPACE FOR DISHWASHER
6. (N) SPACE FOR MICROWAVE AND OVEN
7. (N) FULL-HEIGHT KITCHEN STORAGE CABINET
8. (E) CEILING HEIGHT CHANGE LINE
KEY PLAN
NORTH
1 3
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A4.2
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
C
8 8
1 -4
Scale: 1/2" = 1'-0"
WOODEN SLIDING DOOR ENLARGEMENT PLAN
-3
Scale: 1/2" = 1'-0"
WOODEN SLIDING DOOR ENLARGEMENT PLAN
2 VW
TV
RF
MW
OV
CT
BS
UB-C
UB-C
UB-C
UB-C
UB-C
COT CT
BS
FS
TV
TRAINING ROOM DIMENSIONS & ENLARGEMENT
PLANS 1ST FLOOR|ADMIN BUILDING
CF
CF CF
WP
DIMENSION GENERAL NOTES
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
- TRAINING ROOM - FINISH SCHEDULE 2
A4.2
- -
1. ALL EQUIPMENT AND FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE CODES.
2. CONFIRM ALL EQUIPMENT LOCATIONS, CONNECTIONS, AND CLEARANCES WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS PRIOR TO INSTALLATION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT OR FINISHES.
4. ALL FINISHES TO BE INSTALLED WITH UNIFORM COLOR, TEXTURE, AND PATTERN ALIGNMENT, AS PER APPROVED SAMPLE.
5. ALL MATERIALS SHALL BE NEW, OF COMMERCIAL GRADE, AND FREE OF DEFECTS.
6. SUBMITTALS FOR ALL FINISHES AND EQUIPMENT SHALL BE PROVIDED FOR ARCHITECT’S REVIEW AND APPROVAL PRIOR TO PROCUREMENT.
7. WHERE FINISHES TRANSITION BETWEEN MATERIALS OR COLORS, PROVIDE CLEAN, STRAIGHT LINES AND FINISH EDGES USING MANUFACTURER’S STANDARD TRIM UNLESS NOTED OTHERWISE.
8. ENSURE ALL EQUIPMENT IS FULLY OPERATIONAL AND TESTED PRIOR TO FINAL INSPECTION.
REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.
EQUIPMENT AND FINISH GENERAL NOTES
65" TV
MONITOR
ID NAME IMAGE MFG. DIMENSIONS MATERIAL/FINISH COLOR
EQUIPMENT SCHEDULE
TV
KF
MODEL REMARK
FINISH SCHEDULE
ID NAME IMAGE MFG. LOCATION MATERIAL COLOR
CF
WALL
PAINT
WPT
CPT
FINISH REMARK
CEILING
PAINT
CONCRETE
EPOXY
FLOORING
MODEL
CONCRETE CONCRETE
CRAFT STAINED
THROUGHOUT
ALL THE
FLOORING U.N.O
MATTE
EPOXY
LIGHT
- GRAY/
Per
Manufacture
Specification
SHERWIN
WILLIAMS
SHERWIN
WILLIAMS
THROUGHOUT
ALL THE
WALLS U.N.O
THROUGHOUT
ALL THE
CEILING U.N.O
-
-
WATER- BASED
WATER- BASED
EGGSHELL
FLAT
ALABASTER
SW 7008
PURE WHITE
SW 7005
1 Coat primer, as
needed to full cover
1 Coat primer, as
needed to full cover
DIM.
-
-
-
BACK
SPLASH
BS BACK SPLASH IN
THE KITCHEN
CT COUNTERTOP
UB-C
UPPER
& BASE
CABINET
COT COOKTOP MIELE
(WxHxD)
24 3/4" x 3 1/8" x 21 1/2"
REFRIGERATOR MIELE RF
Casing color Silver
Front color
Stainless
steel/CleanSteel
(WxHxD)
29 2/2" x 73 1/8" x 26 5/8"
Freestanding fridge-freezer
with DailyFresh and NoFrost in 30''
width for a lot of storage space
24-inch induction cooktop, operated
with its own controls
with 3 round cooking zones
BUILT-IN
MICROWAVE MW MIELE
(WxHxD)
23 1/2" x 18" x 22 1/8"
Built-in microwave oven, 24" width
in a design that is the perfect
complement with controls on the top.
BUILT-IN
OVEN OV MIELE CLEAN TOUCH STEEL
(WxHxD)
23 1/2" x 18" x 22 5/8"
24" compact speed oven
in a perfectly combinable design with
automatic programs and combi
modes
TRAINING ROOM EQUIPMENT & FINISH
SCHEDULE 1ST FLOOR|ADMIN BUILDING
SILVER
CLEAN TOUCH STEEL SILVER
SILVER
KITCHEN
FAUCET KOHLER 18.07"(H) VIBRANT STAINLESS
Covered under Kohler's limited lifetime warranty
Faucet body constructed of metal
Single hole mounting type
Deck mounted faucet installs directly to sink or countertop Includes ceramic disc cartridge
Complies with ADA standards
K-28269 SILVER
BLACK KM 7720 FR
KFN 4776 ED
M 7240 TC AM
H 7240 BM AM
SAMSUNG THE FRAME PRO
LS03FW NEO QLED 4K
(WxHxD)
57.4" x 32.9" x 1"
BLACK
Modern Frame Design with Wireless One Connect
Art Mode
Artful Picture Quality with Neo QLED
Samsung Vision AI
CORIAN COUNTERTOP IN
THE KITCHENETTE
LEICHTCA MATTE
UPPER AND BASE
CABINET IN THE
KITCHENETTE
CORIAN CALACATTA
GREIGE
CALACATTA
GREIGE
Hygienic & Easy to Clean
Seamless
Repairable & Renewable
Sustainable
Hygienic & Easy to Clean
Seamless
Repairable & Renewable
Sustainable
CORIAN SOLID BEIGE AND GRAY
SURFACE
GLOSS
CORIAN SOLID
SURFACE
GLOSS BEIGE AND GRAY
-
PER PLAN
PER PLAN
GRIGIO ANTRIM - J0752 MATTE SURFACE, ANTI FINGERPRINT PLYWOOD GRAY - TRAINING ROOM - EQUIPMENT SCHEDULE 1
5 A5.0
CORRIDOR
CORRIDOR
1'-0"
1'-0" 1'-0" C.H.= 8'-0"
3 A5.0 C.H.= 8'-6" C.H.= 8'-3"
C.H.= 8'-10" C.H.= 8'-3" 2" 6" 2" 6" 2" 6" 2'-0" 2" 2'-0" 6" 4'-0" 6"
C.H.= 8'-10"
C.H.= 8'-10"
CORRIDOR
CORRIDOR 2" 6" 2" 6" 6"
6" 3"
C.H.= 9'-0"
C.H.= 8'-9"
C.H.= 8'-6"
2'-0" 6" 2'-0" 6" 2'-0" 6" 2'-0" 6"
2"
+ 9'-6" 1" 3" 3" 3"
+ 8'-0"
C.H.= 8'-0"
EQ.
EQ.
EQ.
EQ.
C.H.= 8'-3" C.H.= 8'-3"
C.H.= 8'-10"
2'-0" 2"
4 A5.0
+ 8'-10" 2'-0" 6" 2'-0"
2" 6" 2" 3" 3" 2" 6" 2" 6" 1"
2'-0"
RECESSED LINEAR LIGHTS
WOOD GRILLE 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0"
A5.0
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -1
Scale: 1/4" = 1'-0"
1ST FLOOR CORRIDOR - CONSTRUCTION PLAN -2
Scale: 1/4" = 1'-0"
1ST FLOOR CORRIDOR - RCP PLAN
KEY PLAN
CONSTRUCTION PLAN NOTES #
NORTH
-5
Scale: 1/2" = 1'-0"
1ST FLOOR CORRIDOR - FLOORING DETAIL
-3
Scale: 1/2" = 1'-0"
1ST FLOOR CORRIDOR - RCP DETAIL PLAN
-4
Scale: 3" = 1'-0"
1ST FLOOR CORRIDOR - RCP DETAIL PLAN
1. PATCH AND REPAIR EXISTING DAMAGED FLOORING SURFACES AS NECESSARY. DEMOLISH AND PROPERLY DISPOSE OF DESIGNATED FLOORING AREAS. ENSURE THE SUBSTRATE IS CLEAN, SMOOTH, AND PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL RESULT IN A STABLE, LEVEL, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH DETAIL 5 ON THIS SHEET, THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS. ENSURE THAT THE INSTALLED FLOORING DOES NOT INTERFERE WITH THE OPERATION OF EXISTING DOORS.
2. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD AND TILE AND TILE AND GRID WITH WOOD GRILL CEILING ATTACHMENT, CEILING IN ACCORDANCE WITH DETAILS 3 AND 4 ON THIS SHEET AND RCP PLANS.
3. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY.
4. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER
INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS.
5. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
6. FURNISH AND INSTALL WOOD GRILL CEILING IN ACCORDANCE WITH THE CORRIDOR RCP ON THIS SHEET AND THE LOUNGE RCP ON SHEET XXXX. ENSURE ALL INSTALLATIONS ARE SECURE, TIGHT, AND SAFE.
ENSURE ALL LIGHTING FIXTURES ARE INSTALLED IN ACCORDANCE WITH THE RCP ON THIS SHEET AND THE LOUNGE RCP ON SHEET XXXX. VERIFY THAT ALL FIXTURES ARE FULLY FUNCTIONAL. (N) DROP CEILING - GYPSUM BOARD
(N) TILE AND GRID 2'X4'
(N) CONCRETE FLOORING
CONSTRUCTION PLAN LEGEND
(E) WALLS TO REMAIN
AREA OF WORK
(E) TILE FLOORING
C.H.= # - # CEILING HEIGHT
(N) WOOD GRILL CEILING
(N) RECESSED LINEAR LIGHT
NEW TILE AND
GRID CEILING
EXISTING FLOORING -
TO REMAIN
(N) TILE FLOORING
CONST. RCP PLAN NOTES
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL GYPSUM BOARD PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS,
MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
5. FURNISH AND INSTALL WOOD GRILL CEILING AT DISPATCH AREA PER DISPATCH RCP AND IN ACCORDANCE WITH MANUFACTURER "HUNTER DOUGLAS ARCHITECTURAL."
#
NEW GYPSUM BOARD
CEILING WITH WOOD
GRILL ATTACHMENT
RCP PLAN LEGEND
EXISTING FLOORING -
TO REMAIN
EXISTING FLOORING -
TO REMAIN
C.H.= 9'-0" C.H.= 9'-0" C.H.= 9'-0" C.H.= 9'-0" 1A7.0 1-2 A6.1 1A6.2 C.H.= 8'-6" C.H.= 9'-6" C.H.= 8'-4" C.H.= 8'-6" 3'-0" 4'-7" 3'-0" 6'-0" 4'-7" 3'-0" 6'-0"3'-0" 3'-2" 3'-2" TV ROOF DECK CORRIDOR KITCHENETTE LOUNGE CONFERENCE ROOM COPY / WORK 1A7.0 1-2 A6.1 1A6.2 UNDER THE SUPERVISION OF: Sheet Number: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: Department of Public Works ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133. UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA Mehran Golestan iArch iArch P.N.: 2.1000.03 NO. DATE BY DESCRIPTION APPROV. REVISIONS CITY OF MONTEBELLO 311 S Greenwood Ave. , Montebello , CA 90640 TRANSPORTATION FACILITY REMODEL CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -1 Scale: 3/16" = 1'-0" 2ND FLOOR CONSTRUCTION PLAN A6.0- - KEY PLAN CONSTRUCTION PLAN NOTES NORTH -2 Scale: 3/16" = 1'-0" 2ND FLOOR RCP PLAN CONSTRUCTION PLAN LEGENDC.H.= # - # CEILING HEIGHT (E) WALLS TO REMAIN AREA OF WORK 1. PATCH AND REPAIR EXISTING DAMAGED FLOORING SURFACES AS NECESSARY. DEMOLISH AND PROPERLY DISPOSE OF DESIGNATED FLOORING AREAS. ENSURE THE SUBSTRATE IS CLEAN, SMOOTH, AND PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL RESULT IN A STABLE, LEVEL, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH DETAIL 1 ON THIS A6.1, THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS. ENSURE THAT THE INSTALLED FLOORING DOES NOT INTERFERE WITH THE OPERATION OF EXISTING DOORS. 2. CONSTRUCT ALL NEW INTERIOR DRY WALLS INCLUDING FULL HEIGHT GLASS PARTITIONS AS INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS. 3. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, TILE AND GRID CEILING WITH ATTACHMENT OF ARMSTRONG IN ACCORDANCE WITH DETAIL 2 ON THIS A6.1 RCP PLANS. 4. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS. 5. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY. 6. FURNISH AND INSTALL ALL BUILT- IN STORAGE UNITS, SHELVING AND COUNTERTOP, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS. 7. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS. 8. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED. 9. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT FOR KITCHENETTE AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH MECHANICAL ENGINEERS TO ENSURE THE PROPER DISCONNECTION, RELOCATION, AND RECONNECTION OF EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY. 10. FURNISH AND INSTALL ALL NEW KITCHEN EQUIPMENT AS SPECIFIED IN THE FIXTURE SCHEDULE AND WALL ELEVATIONS. ENSURE PROPER ALIGNMENT, CONNECTIONS, AND FUNCTIONALITY PER MANUFACTURER REQUIREMENTS AND PROJECT SPECIFICATIONS. 11. FURNISH AND INSTALL SINGLE LAYER TEXTILE ROOFING , IN ACCORDANCE WITH "TENSION STRUCTURE" MANUFACTURER SPECIFICATIONS. 12. FURNISH AND INSTALL ROLL-UP COUNTER GRILLS IN ACCORDANCE WITH "INDUSTRIAL ROLL-UP DOORS" MANUFACTURE SPECIFICATIONS AND FRAMELESS FOLDING DOORS IN ACCORDANCE WITH "PREMIER FOLDING DOORS" MANUFACTURE SPECIFICATIONS. 13. FURNISH AND INSTALL NEW STRUCTURAL FRAME FOR RECEIVING MOSAIC GLASS SHEET ON THE EXISTING SQUARE GLASS BLOCK SYSTEM IN ACCORDANCE WITH DETAIL "4" AND ENLARGEMENT WALL VIEW ON SHEET "A6.3". FURNISH AND INSTALL SHEATHING PANELS OVER THE REMAINING SQUARE GLASS BLOCK AREAS AS INDICATED IN THE SAME DETAIL AND ENLARGED VIEW. 14. REPLACE ALL EXISTING FIBERGLASS SHEETS ON THE ROOF DECK CEILING. ENSURE NO DAMAGE IS CAUSED TO THE EXISTING CEILING STRUCTURE DURING REPLACEMENT. NOTES: 1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A6.4 2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0 CONST. RCP PLAN NOTES 1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING. 2. FURNISH AND INSTALL ALL TILE AND GRID PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. 3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION. 4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. (AS NEEDED) # NORTH
NEW FLOORING -
TO INSTALL NEW TILE AND GRID CEILING NEW GYPSUM BOARD CEILING WITH ARMSTRONG ATTACHMENT (N) CEILING LIGHTING (N) TILE FLOORING (N) DROP CEILING - GYPSUM BOARD (N) TILE AND GRID 1'X1' (N) RECESSED LINEAR LIGHT
(N) HARD WOOD FLOORING
(N) CARPET FLOORING(N) WALLS TO CONSTRUCT CONSTRUCTION RCP PLAN LEGEND THE CEILING LAYOUT IS COORDINATED TO ALIGN WITH THE FLOORING DESIGN AND LAYOUT. THE CEILING LAYOUT IS COORDINATED TO ALIGN WITH THE FLOORING DESIGN AND LAYOUT. CONSTRUCTION KEY NOTES # 1. (N) FULL HEIGHT GLASS WALL 2. (N) NEW TV TO INSTALL 3. (N) PENDANT LIGHTING 4. (N) FOLDING SLIDING MOVABLE WALL PARTITIONS WITH WHEELS 5. (N) ROLL - UP COUNTER GRILLS 6. (N) BUILT-IN BENCH 7. (N) SPACE FOR REFRIGERATOR 1 111111 4 6 5 7 8 3 3 (N) LED CEILING MOUNTED LIGHT 9 C.H.= # - # CEILING HEIGHT (N) CEILING PENDANT LIGHTING TYP. TYP. (N) TILE FLOORING 8. (N) SINGLE LAYER TEXTILE ROOFING 9. (N) ACCENT WALL - SEE SHEET A6.2
C.H.= 9'-0" C.H.= 9'-0" 2'-1" 9" 1'-0" 1'-0" 1'-0" 1'-1" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0"1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" 1'-1" 1'-0" 1'-0" 1'-0" 2" 11" 1'-0" 1'-0" A6.1- - UNDER THE SUPERVISION OF: Sheet Number: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: Department of Public Works ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133. UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA Mehran Golestan iArch iArch P.N.: 2.1000.03 NO. DATE BY DESCRIPTION APPROV. REVISIONS CITY OF MONTEBELLO 311 S Greenwood Ave. , Montebello , CA 90640 TRANSPORTATION FACILITY REMODEL CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -1 Scale: 3/8" = 1'-0" 2ND FLOOR FLOORING ENLARGEMENT KEY PLAN NORTH -2 Scale: 3/8" = 1'-0" 2ND FLOOR RCP ENLARGEMENT CONSTRUCTION PLAN NOTES # CONSTRUCTION PLAN LEGEND C.H.= # - # CEILING HEIGHT (E) WALLS TO REMAIN AREA OF WORK 1. PATCH AND REPAIR EXISTING DAMAGED FLOORING SURFACES AS NECESSARY. DEMOLISH AND PROPERLY DISPOSE OF DESIGNATED FLOORING AREAS. ENSURE THE SUBSTRATE IS CLEAN, SMOOTH, AND PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL RESULT IN A STABLE, LEVEL, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH DETAIL 1 ON THIS SHEET, THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS. ENSURE THAT THE INSTALLED FLOORING DOES NOT INTERFERE WITH THE OPERATION OF EXISTING DOORS. 2. CONSTRUCT ALL NEW INTERIOR DRY WALLS INCLUDING FULL HEIGHT GLASS PARTITIONS AS INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS. 3. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, TILE AND GRID CEILING WITH ATTACHMENT OF ARMSTRONG IN ACCORDANCE WITH DETAIL 2 ON THIS SHEET RCP PLANS. 4. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS. 5. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY. NOTES: 1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A6.4 2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0 CONST. RCP PLAN NOTES 1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING. 2. FURNISH AND INSTALL ALL TILE AND GRID PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. 3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION. 4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. (AS NEEDED) # (N) CEILING LIGHTING (N) TILE FLOORING (N) HARD WOOD FLOORING (N) CARPET FLOORING (N) WALLS TO CONSTRUCT CONSTRUCTION RCP LEGEND 1
ALIGN NEW TILE AND
ALIGN GRID CEILING NEW GYPSUM BOARD CEILING WITH ARMSTRONG ATTACHMENT (N) INSTALLATION GUIDE LINES FOR CEILING AND FLOORING THE CEILING LAYOUT IS COORDINATED TO ALIGN WITH THE FLOORING DESIGN AND LAYOUT. THE CEILING LAYOUT IS COORDINATED TO ALIGN WITH THE FLOORING DESIGN AND LAYOUT. CONSTRUCTION KEY NOTES # 1. (N) GYPSUM BOARD 2. (N) FULL HEIGHT GLASS WALL 3. (N) CARPET FLOORING - TO INSTALL 4. (N) TILE FLOORING 5. (N) HARDWOOD FLOORING(N) TILE AND GRID 1'X1' 222222 5 5 4 4 4 4 4TYP. TYP. TYP. TYP. TYP. 3 5 3 3 3 2 1 1
TV ROOF DECK CORRIDOR KITCHENETTE LOUNGE 4A6.2 6A6.2 3A6.25A6.2 10" 9" 8" 7" 6" 4" 7" 6" 4" 4"
2"
4" 11"
2" 2'-0"
2'-0" 8'-7"
6'-11" 2A6.2 11"
4"
7"
6"
6"
7" 8" 9" 10" 11"
4" 4" 2" 2" 8" 0" 0" 1'-4" 0" 3'-0" 2'-6" 10" 1'-0" 1'-6" 2'-0" 5'-2"
2'-0"
1'-4"
10"
7"
4" 4" 5A6.2 5'-0" NATURAL QUARTZ BENCH SURFACE (60"x24"x1") 1'-6" PARLIAMENT HINGE STUD WALL LATCH OPERATING GLASS FIXED GLASS FIXED GLASS FIXED GLASS STUD WALL A6.2- - UNDER THE SUPERVISION OF: Sheet Number: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: Department of Public Works ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133. UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA Mehran Golestan iArch iArch P.N.: 2.1000.03 NO. DATE BY DESCRIPTION APPROV. REVISIONS CITY OF MONTEBELLO 311 S Greenwood Ave. , Montebello , CA 90640 TRANSPORTATION FACILITY REMODEL CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -2 Scale: 1/2" = 1'- 0" ROOF DECK FLOORING MODULE -1 Scale: 1/4" = 1'- 0" ROOF DECK & LOUNGE FLOORING -5 Scale: N.T.S FULL HEIGHT GLASS WALL ENLG. -4 Scale: 3/4" = 1'- 0" ROOF DECK FLOORING ENLAREMENT LAYOUT KEY PLAN NORTH -6 Scale: 1/2" = 1'- 0" ROOF DESK BUILT-IN BENCH DETAILDIMENSIONS AND FEATURES SHOWN ON ONE QUARTER APPLY IDENTICALLY TO THE OTHER THREE QUARTERS, WHICH ARE MIRRORED VERSIONS OF EACH OTHER (N) TILE FLOORING CONSTRUCTION PLAN NOTES # CONSTRUCTION PLAN LEGEND (E) WALLS TO REMAIN AREA OF WORK 1. PATCH AND REPAIR EXISTING DAMAGED FLOORING SURFACES AS NECESSARY. DEMOLISH AND PROPERLY DISPOSE OF DESIGNATED FLOORING AREAS. ENSURE THE SUBSTRATE IS CLEAN, SMOOTH, AND PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL RESULT IN A STABLE, LEVEL, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH DETAIL 1 ON THIS A6.1, THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS. ENSURE THAT THE INSTALLED FLOORING DOES NOT INTERFERE WITH THE OPERATION OF EXISTING DOORS. 2. CONSTRUCT ALL NEW INTERIOR DRY WALLS INCLUDING FULL HEIGHT GLASS PARTITIONS AS INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS. 3. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, TILE AND GRID CEILING WITH ATTACHMENT OF ARMSTRONG IN ACCORDANCE WITH DETAIL 2 ON THIS A6.1 RCP PLANS. 4. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS. 5. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY. 6. FURNISH AND INSTALL ALL MILLWORKS INCLUDING BUILT- IN STORAGE UNITS, SHELVING AND COUNTERTOP, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS. 7. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS. 8. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED. 9. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT FOR KITCHENETTE AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH MECHANICAL ENGINEERS TO ENSURE THE PROPER DISCONNECTION, RELOCATION, AND RECONNECTION OF EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY. 10. FURNISH AND INSTALL ALL NEW KITCHEN EQUIPMENT AS SPECIFIED IN THE FIXTURE SCHEDULE AND WALL ELEVATIONS. ENSURE PROPER ALIGNMENT, CONNECTIONS, AND FUNCTIONALITY PER MANUFACTURER REQUIREMENTS AND PROJECT SPECIFICATIONS. 11. FURNISH AND INSTALL ROLL-UP COUNTER GRILLS IN ACCORDANCE WITH "INDUSTRIAL ROLL-UP DOORS" MANUFACTURE SPECIFICATIONS AND FRAMELESS FOLDING DOORS IN ACCORDANCE WITH "PREMIER FOLDING DOORS" MANUFACTURE SPECIFICATIONS MO 12. FURNISH AND INSTALL NEW STRUCTUAL FRAME FOR RECEIVING MOSAIC GLASS SHEET ON THE EXISTING SQUARE GLASS BLOCK SYSTEM IN ACCORDANCE WITH DETAIL "4" AND ENLARGEMENT WALL VIEW ON SHEET "A6.3". FURNISH AND INSTALL SHEATHING PANELS OVER THE REMAINING SQUARE GLASS BLOCK AREAS AS INDICATED IN THE SAME DETAIL AND ENLARGED VIEW. 14. REPLACE ALL EXISTING FIBERGLASS SHEETS ON THE ROOF DECK CEILING. ENSURE NO DAMAGE IS CAUSED TO THE EXISTING CEILING STRUCTURE DURING REPLACEMENT. (N) HARD WOOD FLOORING (N) CARPET FLOORING (N) WALLS TO CONSTRUCT CONSTRUCTION KEY NOTES # 1. (N) FULL HEIGHT GLASS WALL 2. (N) NEW TV TO INSTALL 3. (N) FOLDING SLIDING MOVABLE WALL PARTITIONS WITH WHEELS 4. (N) ROLL - UP COUNTER GRILLS 5. (N) BUILT-IN BENCH - DETAIL "5 " ON SHEET "A6.2" 6. (N) SPACE FOR REFRIGERATOR 7. (N) MIRROR AXIS 1 2 1 2 2 2 222222 3 4 6 699 9 11 11 12 87 1 2 2 3 4 5 6 -3 Scale: 1/2" = 1'- 0" FULL HEIGHT GLASS WALL 7 1 1 1 1 1
TV ROOF DECK CORRIDOR KITCHENETTE LOUNGE 2A6.3
2'-0" 2'-11" 2'-0" 7" 2'-0" 1'-0" 1'-8" 1'-6" 2'-8" 2'-0" 4" 11'-9" 5'-1" 10'-5" 3'-4"
4" 8'-1" 4" 4'-10" 5'-8"
2'-0" 5'-9"11" 1'-0"
5'-6" 10'-4" 18'-2" 6A6.3 6A6.3 Drawer 1'-5" 1'-5" 1'-2" 1'-2" 1'-0" 1'-0" 4" 2'-0" 1'-6" 3'-0" 2'-0" 3'-0" Drawer 4"
1'-6" 2"
9'-5"
1'-4" 3'-1" 10'-8" 4" 2'-4" 4" 2'-5" 8" 2'-0" 10" 1'-6" 1'-0" 1'-0" 1'-4" 10" 2'-0" 6" 10'-8" 3'-1" 3'-0" 6" 2'-0" 10" 1'-4" 1'-0" 1'-0" 1'-6" 10" 2'-1" 8" 9'-0" 2'-11" FRANK BLUE FRANK BLUE FRANK BLUE ORANGE FRANK BLUEORANGE ORANGE ORANGE ORANGE TRANSPARENT STAINED GLASS TRANSPARENT STAINED GLASS TRANSPARENT STAINED GLASS TRANSPARENT STAINED GLASS TRANSPARENT STAINED GLASS (N) SQUARE TUBE PROFILE(1"*1") SHALL BE WELDED TO THE PREVIOUS PROFILE FOR GLASS FRAMING. (E) PROFILE 1'-0" 1'-0" 1'-0"1'-0" UNDER THE SUPERVISION OF: Sheet Number: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: Department of Public Works ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133. UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA Mehran Golestan iArch iArch P.N.: 2.1000.03 NO. DATE BY DESCRIPTION APPROV. REVISIONS CITY OF MONTEBELLO 311 S Greenwood Ave. , Montebello , CA 90640 TRANSPORTATION FACILITY REMODEL CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -2 Scale: 1/4" = 1'- 0" ROOF DECK ACCENT WALL STR. -1 Scale: 1/4" = 1'- 0" ROOF DECK WALL VIEWS AND DETAIL -5 Scale: 1/4" = 1'- 0" ROOF DECK WALL VIEW "C" -7 Scale: 1/4" = 1'- 0" ROOF DECK WALL VIEW "B" -4 Scale: 1/4" = 1'- 0" ROOF DECK WALL VIEW "A" A6.3- - KEY PLAN NORTH B A C DIMENSION PLAN NOTES 1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY. 2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK. 3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED. 4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER. 5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK. 6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE. 7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS. 8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES. 9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE. 10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY. 11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS. 12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION. CONSTRUCTION PLAN LEGEND (E) WALLS TO REMAIN AREA OF WORK (N) TILE FLOORING (N) HARD WOOD FLOORING (N) CARPET FLOORING (N) WALLS TO CONSTRUCT -6 Scale: 1/2" = 1'- 0" ACCENT WALL DETAILS CONSTRUCTION KEY NOTES # 1. (N) FULL HEIGHT GLASS WALL 2. (N) SCONCE LIGHTING - TO REPLACE 3. (N) FOLDING SLIDING MOVABLE WALL PARTITIONS WITH WHEELS 4. (N) ROLL - UP COUNTER GRILLS 5. (N) BUILT-IN BENCH 6. (N) SPACE FOR REFRIGERATOR 7. (N) SINGLE LAYER TEXTILE ROOFING 8. (N) ACCENT WALL 9. (E) SQUARE GLASS BLOCK STRUCTURE SYSTEM 10. (N) PROFILE STRUCTURE TO SUPPORT NEW MOSAIC GLASS 11. (E) WALL - TO REMAIN 12. (N) SHEATHING PANEL 13. (N) MOSAIC GLASS SHEET 14. (N) PENDANT LIGHTING 15. (N) FIBER GLASS SHEETS - TO REPLACE 1 3 1111 4 5 6 7 8 1 1 1 -3 Scale: 1/4" = 1'- 0" ROOF DECK ACCENT WALL DETAILS 9 10 11 11 12 1 5 7 13 TYP. 14 TYP. 1515 CT BSP 1 1 1 1 1 1 1 1 1 1 1
UNDER THE SUPERVISION OF: Sheet Number: DESIGNED BY: DRAWN BY: CHECKED BY: DATE: Department of Public Works ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133. UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA Mehran Golestan iArch iArch P.N.: 2.1000.03 NO. DATE BY DESCRIPTION APPROV. REVISIONS CITY OF MONTEBELLO 311 S Greenwood Ave. , Montebello , CA 90640 TRANSPORTATION FACILITY REMODEL CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -3 Scale: N.T.S EQUIPMENT SCHEDULE A6.4- - -1 Scale: N.T.S FINISH SCHEDULE -2 Scale: N.T.S ROOF DECK - TILE SCHEDULE ID NAME IMAGE MANUFACTURE DIMENSIONS MATERIAL/FINISH COLOR EQUIPMENT SCHEDULE MODEL REMARK SECURITY GRILL ROLLING SHUTTER SGTV 85" TV MONITOR SAMSUNG 85" Q80D QLED 4K 74.5" X 42.6" X 1.9" GOOGLE SMART TV WITH ALEXA COMPATIBILITY, QLED, 120HZ, DOLDY ATMOS, HDR10+, 360 AUDIO, HANDS FREE, MOTION TECHNOLOGY _ BLACK RF PREMIERFOLDINGDOORS FRAMELESS FOLDING DOORS 16'.8" x 9" (W x H ) AT ARMSTRONGCEILINGS 12" x 12" (W x H ) FACTORY FINISH WHITE TONGUE & GROOVE (NO VISIBLE GRID) IMPRESSION 1134 ARMSTRONG TS SINGLE LAYER TEXTILE ROOFING TENSION STRUCTURES MONOTEC 370 SHADE CLOTH 16'x 19' (W x D ) FABRIC TENSILE BEIGE MG UNICOSHAPE MOSAIC GLASS SHEET 12"x 12" (W x D ) PREMIUM MOSAIC GLASS SHEETS – THESE BEAUTIFUL, HIGH-QUALITY SHEETS OF COLORS GLASS ARE THE PERFECT WAY TO ENHANCE THE LOOK OF A MODERN, FARMHOUSE, OR BOHO STYLE ART PIECE AND ADD COLOR VIBRANCE THAT REALLY STANDS OUT. STAINED GLASS TRANPARENCY ORANGE BLUE FACTORY FINISH TRANPARENCY MOSAIC GLASS SHEET COT COOKTOP MIELE (WxHxD) 24 3/4" x 3 1/8" x 21 1/2" PREMIER FOLDING DOOR BLACK MIELE/ KM 7720 FR ELEGANT GLASS CERAMIC SURFACE 24-INCH INDUCTION COOKTOP, OPERATED WITH ITS OWN CONTROLS WITH 3 ROUND COOKING ZONES BUILT-IN MICROWAVE MW MIELE/ M 7240 TC AM (WxHxD) 23 1/2" x 18" x 22 1/8" CLEAN TOUCH STEEL BUILT-IN MICROWAVE OVEN, 24" WIDTH IN A DESIGN THAT IS THE PERFECT COMPLEMENT WITH CONTROLS ON THE TOP MIELE BLACK REFRIGERATOR MIELE/ KFN 4776 ED RF (WxHxD) 29 2/2" x 73 1/8" x 26 5/8" FREESTANDING FRIDGE-FREEZER WITH DAILYFRESH AND NOFROST IN 30'' WIDTH FOR A LOT OF STORAGE SPACE UNDERMOUNT SINGLE BASIN SINK US (H x W x D) CORIAN 61/4" X 171/2" X 281/2" CORIAN / BONE MADE FROM AN ACRYLIC-POLYESTER SOLID SURFACE ADA COMPLIANT WHEN INSTALLED ACCORDING TO GUIDELINES CASING COLOR: SILVER FRONT COLOR: STAINLESS STEEL / CLEANSTEEL MIELE STAINLESS STEEL ACCESSIBLE-5610 WHITE KITCHEN FAUCET KF KOHLER 18.07"(H) VIBRANT STAINLESS COVERED UNDER KOHLER'S LIMITED LIFETIME WARRANTY FAUCET BODY CONSTRUCTED OF METAL SINGLE HOLE MOUNTING TYPE K-28269 SILVER 4' - 6" x 4' HARMONIUS SSG-19 OPERATION: LIFT-UP, CRANK, OR MOTOR OPERATOR SILVER ALUMINUM TILE SCHEDULE FLOORING TILE ID NAME IMAGE QUANTITY MANUFACTURE REMARK FT SIZE 4"x 4" 6"x 6" 7"x 7" 8"x 8" 9"x 9" 10"x 10" 24 32 40 48 56 64 DALTILE OFF WHITE(MATTE) MARBLE HAS BEEN USED TO CREATE SOME OF ARCHITECTURE AND DESIGN'S MOST IMPRESSIVE STRUCTURES. LOCATION MATERIAL COLOR COPY ROOM,DECK ,KITCHEN AND PART OF HALLWAY PORCELAIN 12"x 12" AS NEEDED (THE REST OF AREA) THE ABILITY TO PLACE A FULLY RETRACTABLE DOOR IN THE MIDDLE OF A GLASS ENCLOSURE IS SOMETHING THAT NO OTHER MANUFACTURER HAS BEEN ABLE TO PROVIDE. NOW, WITH THE INTRODUCTION OF GLASS CURTAINS™ BRAND-NEW FLYING DOOR SYSTEM, WE HAVE ADDRESSED THIS CONSUMER DEMAND AND HAVE MADE IT AVAILABLE JUST FOR FINISH SCHEDULE ID NAME IMAGE MFG. LOCATION DIM. MODEL MATERIAL FINISH COLOR REMARK WPCPCT UB-C CAF BS BSP CP 1 CP 2 CP 3 AT WALL PAINT COUNTERTOP CEILING PAINT UPPER & BASE CABINET BENCH SLAB CARPET FLOORING BACK SPLASH CEILING PAINT CEILING PAINT CEILING PAINT ARTIFICIAL TURF WILSONART SHERWIN-WILLIAMS SHERWIN-WILLIAMS MOHAWKGROUP FENIXFORINTERIORS-NA MSISURFACE FLOOR&DECOR SHERWIN-WILLIAMS SHERWIN-WILLIAMS SHERWIN-WILLIAMS CHAMANINC THROUGHOUT ENTIRE BUILDING WALLS, U.N.O. THROUGHOUT ENTIRE BUILDING CEILING, U.N.O. THROUGHOUT DISPATCH, U.N.O. THROUGHOUT DISPATCH, U.N.O. AS SHOWN IN PLANS BENCH SURFACE 2 1/2" x 8" LIMESTONE IVORY PORCELAIN TILE THROUGHOUT ENTIRE BUILDING CEILING, U.N.O. THROUGHOUT ENTIRE BUILDING CEILING, U.N.O. THROUGHOUT ENTIRE BUILDING CEILING, U.N.O. ROOF DECK WATER-BASED PREMIUM CEILING PAINT PREMIUM LAMINATE PLYWOOD DURACOLOR® TRICOR PREMIUM NYLON CALACATTA LAPIZA NATURAL QUARTZ CERAMIC HIGH GLOSS PREMIUM CEILING PAINT PREMIUM CEILING PAINT PREMIUM CEILING PAINT ARTIFICIAL TURF 1 COAT PRIMER, 2 COAT FINISH WHITE 1 COAT PRIMER, 2 COAT FINISH ACCESSIBLE BEIGE SW 7036 OURO BRANCO - 5029K-22 577 SODALITE BEIGE ARIZONA - J0748 MATTE SURFACE, ANTI FINGERPRINT TARR: HEAVY GSA STAIN RELEASE: PASS FLAMMABILITY: ASTM E648: CLASS 1-GLUE DOWN AATC 134: UNDER 3.5 KV ASTM E662: LESS THAN 450 GREENGUARD Gold Certificate Edgeband GREENGUARD Gold Certificate RE-COVER™ Laminate FSC Mixed Certificate for Laminate Recycled Content - Laminate Types 335, 735 Recycled Content Laminate - Types 350, 376, 776 POLISHED WHITE WARM PER MANUFACTURER SPECIFICATION WHITE ORANGE 1 COAT PRIMER, 2 COAT FINISH 1 COAT PRIMER, 2 COAT FINISH 1 COAT PRIMER, 2 COAT FINISH BLUE GRAY GREEN ZELLIGE PEARL OPAL EASY TO INSTALL, CLEAN AND MAITAIN 5' x 2' MATTE MATTE MATTE MATTE MATTE GLOSSY MATTE 5' x 2' GLOSSY TACTILE INFUSION GT422 FG FIBER GLASS SHEETS KALWALL _ _ FIBER GLASS / TRANSLUCENT WHITE _ KALCURVE _
ADMIN. SEC. CONFERENCE ROOM
4 A7.1 2'-6" 3'-11" 2'-6"
3'-5"
4'-10" 3'-4" 3'-3" 4'-10" 3'-0" 3'-4" 4'-2" 2'-5" 3'-0" 3'-0" 1'-1" 15'-0" 3'-1" 3'-0" 2'-0" 2'-6" 2'-9" 2'-6" 2'-9" 2'-6" 2'-0" 1'-5"
CONFERENCE ROOM
3'-7" 2'-1" 3'-4" 14'-4" 3'-4" 2'-1" 1'-4" 1'-6" 2'-3" 6" 12'-8" 4" 3'-4" 4'-11"
5'-1"
ADMIN SEC.
3'-5"
1'-6" 1'-6" 1'-6" 1'-6"1'-6"
6" 16'-11" 9" 16'-3" 9" 15'-3" 9" 14'-0" 9" 15'-6" 1'-6" 2'-9" EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. 9'-11" 1'-6" 3'-3" 1'-6" EQ. EQ.
EQ.
EQ.
EQ.
C.H.= 8'-6"
2'-9" 6" 2'-9" 6" 2'-9" 6" 2'-9" 6" 2'-9" 6" 2'-9"
6"
6"
6"
6"
5 A7.0
6 A7.0 17'-4"
1'-0" 9" 5'-6"
C.H.= 8'-4" 2"
2'-10" 2'-10" 2'-10" 4'-3" 4'-3" 4'-3" 3'-4"
2'-0" 3'-2" 3'-4" 5'-2" 3'-4" 6'-8" 3'-4" 7'-9" 3'-4" 8'-6" 3'-4" 8'-11" C.H.= 9'-6" 1'-2"
2'-9" 2'-9" 2'-9" 2'-9" 2'-9" 2'-9" 6" 6" 6" 6" 6"
+ 8'-6" 1'-0"
+ 9'-6"
4 A7.0
2'-0" 2" 1'-0" 2"
+ 8'-6"
+ 9'-6"
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT NORTH
A B
-6
Scale: 1/4" = 1'-0"
CONFERENCE ROOM - CEILING DETAIL
A7.0
- -
-1
Scale: 1/4" = 1'-0"
CONFERENCE ROOM - CONSTRUCTION PLAN
-2
Scale: 1/4" = 1'-0"
CONFERENCE ROOM - DIMENSION PLAN
(N) DOOR SCHEDULE
CONSTRUCTION PLAN LEGEND
KEY PLAN
(E) WALLS TO REMAIN
AREA OF WORK
1. PATCH, AND REPAIR ALL DAMAGED FLOORING SURFACES AS NECESSARY. ENSURE THE SUBSTRATE IS PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS
SHALL PROVIDE A SMOOTH, STABLE, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS.
2. CONSTRUCT ALL NEW INTERIOR DRYWALLS AND FURNISH AND INSTALL FULL-HEIGHT GLASS PARTITIONS, SUPPORTED BY THE "SMART GLASS WHITEBOARD" SYSTEM, IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS BY "INNOVATIVE GLASS," AS INDICATED BY HATCH PATTERNS ON THE CONSTRUCTION DRAWINGS. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS.
3. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, CEILING IN ACCORDANCE WITH RCP PLANS.
4. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS.
5. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY.
6. FURNISH AND INSTALL ALL MILLWORKS INCLUDING BUILT- IN STORAGE UNITS, SHELVING AND
COUNTERTOP, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS.
7. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS.
ENSURE PROPER INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS.
8. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
9. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH MECHANICAL
ENGINEERS TO ENSURE THE PROPER DISCONNECTION, RELOCATION, AND RECONNECTION OF
EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY.
10. FURNISH AND INSTALL ALL NEW KITCHEN, EQUIPMENT AND MISCELLANEOUS IN ACCORDANCE WITH CONSTRUCTION PLANS AND MANUFACTURER'S SPECIFICATIONS. ENSURE PROPER CONNECTIONS, ALIGNMENT, AND FUNCTIONALITY OF ALL UNITS.
CONSTRUCTION PLAN NOTES #
CONSTRUCTION KEY NOTES #
1. (N) TV TO INSTALL
2. (N) SMART GLASS WHITEBOARD
3. (N) FACET HANGING WINDOW COVER
4. (N) LINEAR LED LIGHTING
5. (N) BRUSHED STEEL SHEET
(N) WALLS TO CONSTRUCT
(N) FLOOR TRANSITION
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A7.2
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
1 1
4 4
2 2
4 6
6 10
(N) HARD WOOD FLOORING
(N) CARPET FLOORING
CEILING HEIGHT
(N) LED CEILING MOUNTED LIGHT
C.H.= #-#
(N) DROP CEILING - GYPSUM BOARD
1 -5
Scale: 3/8" = 1'-0"
CONFERENCE ROOM - CEILING SECTION
-4
Scale: 3/8" = 1'-0"
CONFERENCE ROOM - CEILING SECTION
CONST. RCP PLAN NOTES
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL TILE AND GRID PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS,
MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
5. FURNISH AND INSTALL BRUSHED STEEL SHEET GRILL CEILING IN ACCORDANCE WITH RCP, SECTIONS "5" AND "6" AND DETAIL "4" ON THIS SHEET.
#
3 2
3 C
5 TYP.
4 TYP.
4 TYP.
5 TYP.
5 4
(N) RECESSED LINEAR LIGHT
1 US
SG
HF
CAF
FP
1 = Baffle
2 = End cap
3 = Locking plate
4 = Carrier
5 = Primary grid
6 = Nonius hanger upper part
7 = Nonius hanger lower part
8 = Nonius hanger locking clip
-3
Scale: 1/4" = 1'-0"
CONFERENCE ROOM - REFLECTED CEILING PLAN
2
9'-0" 2'-10" 1'-6" 4'-8" 2'-6"
1'-0" 9'-0" 5'-0" 1'-6"
1'-0"1'-11"
2'-0" 9'-0"
6'-3" 2'-0" 1'-9" 2'-6" 5'-0"
21'-10"
7'-9" 4'-1" 1'-6" 9'-1" 1'-4" 1'-3" 4'-6" 2'-0" 9'-0" 1'-10" 1'-7" 2'-7" 3'-0" 2'-6" 3'-0"
16'-4" 7'-0" 2'-0" 9'-0"
EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ.
EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ.
2'-6" 3"
6"
WALNUT WOOD, COLOR-MATCHED
TO THE HARDWOOD FLOORING 2'-3"
15'-0"
1"
THE SILVER FINISH COORDINATED
WITH THE SILVER CEILING
1'-10" 2'-6" 2'-6" 3'-11"
12'-6" 4'-2"2'-6"
15'-0"
5 A7.1
6 A7.1 4'-9"
15'-0"
15'-8"
11" 3"
13'-0"
8"
2'-6" 2'-6" 3"
1'-11" 2'-3"
6" 6" 1'-11"
WALNUT WOOD, COLOR-MATCHED
TO THE HARDWOOD FLOORING
THE SILVER FINISH COORDINATED
WITH THE SILVER CEILING
-3
Scale: 1/2" = 1'-0"
CONFERENCE ROOM - WALL VIEW "C"
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -1
Scale: 1/2" = 1'-0"
CONFERENCE ROOM - WALL VIEW "A"
-2
Scale: 1/2" = 1'-0"
CONFERENCE ROOM - WALL VIEW "B"
A7.1
- -
NORTH
CONSTRUCTION PLAN LEGEND
KEY PLAN
AREA OF WORK
CONSTRUCTION KEY NOTES #
1. (N) TV TO INSTALL
2. (N) SMART GLASS WHITEBOARD
3. (N) FACET HANGING WINDOW COVER
4. (N) BUILT-IN REFRIGERATOR -4
Scale: 1/2" = 1'-0"
CONFERENCE ROOM - CONFERENCE TABLE ENLARGMENT
-5
Scale: 1/2" = 1'- 0"
CONFERENCE ROOM - CONFERENCE TABLE DETAIL
-6
Scale: 1/2" = 1'- 0"
CONFERENCE ROOM - CONFERENCE TABLE DETAIL
1 2
1 2
TV
BR
4 KF BC
BS
CT
UB-C
UB-C
UB-C
UB-C
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A7.2
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
SG
DIMENSION GENERAL NOTES
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT A7.2
- -
SMART GLASS
ID NAME IMAGE MANUFACTURE DIMENSIONS MATERIAL/FINISH COLOR
EQUIPMENT SCHEDULE
MODEL REMARK
FINISH SCHEDULE
ID NAME IMAGE MFG. LOCATION MATERIAL COLOR
WPT
CPT
MODEL FINISH REMARK
Per
Manufacture
Specification
SHERWIN
WILLIAMS
SHERWIN
WILLIAMS
THROUGHOUT
ALL THE
WALLS U.N.O
THROUGHOUT
ALL THE
CEILING U.N.O
WATER- BASED
WATER- BASED
EGGSHELL
FLAT
ALABASTER
SW 7008
PURE WHITE
SW 7005
1 Coat primer, Paint as
needed to full cover
1 Coat primer, Paint as
needed to full cover
MATTE
DIM.
GROUT JOINT
1/16"
COLORMATCHED
GROUT
FINISH
-
- BS FLOOR&DECOR BACK SPLASH IN
THE KITCHENETTE 2 1/2" x 8" ZELLIGE PERLA CERAMIC
CT
UB-C
GLOSS
GROUT JOINT
1/16"
COLORMATCHED
GROUT
FINISH
85" TV
MONITOR SAMSUNG (H x W x D)
74.5" X 42.6" X 1.9"
GOOGLE SMART TV WITH ALEXA COMPATIBILITY, QLED, 120HZ,
DOLDY ATMOS, HDR10+, 360 AUDIO, HANDS FREE, MOTION
TECHNOLOGY
TV 85" Q80D QLED 4K _
BUILT-IN
REFRIGERATOR MIELE
(H x W x D)
83.8" X 30" X 24" 30 Inch Smart Column Refrigerator with 475 Cu. Ft. Capacity BR K 2812 VI
BUILT-IN
COFFEE MAKER
(H x W x D)
19" X 30" X 24"
Large touch display with proximity sensor – M Touch + MotionReact Individual coffee enjoyment with 3 bean containers –CoffeeSelect Perfect care – fully automatic withAutoDescale and AutoClean Perfectly positioned: thanks to the patentedCupSensor
2 coffees at once at the touch of a button –OneTouch for Two
BC FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
MIELE CVA 7775
CORIAN COUNTERTOP IN NUWOOD CORIAN / QUARTZ
THE KITCHENETTE
LEICHTCA MATTE
UNDERMOUNT
SINGLE BASIN
SINK
US
(H x W x D)
61/4" X 171/2" X 281/2" CORIAN CORIAN / BONE Made from an acrylic-polyester solid surface ADA compliant when installed according to guidelines ACCESSIBLE-5610 _
_
FACET
HANGING
WINDOW
COVER
FP
FULLY RECYCLABLE, FIRE RETARDANT, UV
RESISTANT, ANTISTATIC AND EASY TO CLEAN
PCABS, ALUMINUM
AND STAINLESS
STEEL
FACET
HANGING
ROOM DIVIDER
PER PLAN _
KITCHEN
FAUCET
KF KOHLER 18.07"(H) VIBRANT STAINLESS
Covered under Kohler's limited lifetime warranty
Faucet body constructed of metal
Single hole mounting type
Deck mounted faucet installs directly to sink or countertop Includes ceramic disc cartridge
Complies with ADA standards
K-28269
WOOD HARDWOOD
FLOORING HF REDDYSHARDWOOD AS SHOWN IN PLAN STAIN WALNUT
CAF MOHAWK GROUP CARPET
FLOORING AS SHOWN IN PLAN
UPPER AND BASE
CABINET IN THE
KITCHENETTE
NORTH
KEY PLAN
1. ALL EQUIPMENT AND FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE CODES.
2. CONFIRM ALL EQUIPMENT LOCATIONS, CONNECTIONS, AND CLEARANCES WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS PRIOR TO INSTALLATION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT OR FINISHES.
4. ALL FINISHES TO BE INSTALLED WITH UNIFORM COLOR, TEXTURE, AND PATTERN ALIGNMENT, AS PER APPROVED SAMPLE.
5. ALL MATERIALS SHALL BE NEW, OF COMMERCIAL GRADE, AND FREE OF DEFECTS.
6. SUBMITTALS FOR ALL FINISHES AND EQUIPMENT SHALL BE PROVIDED FOR ARCHITECT’S REVIEW AND APPROVAL PRIOR TO PROCUREMENT.
7. WHERE FINISHES TRANSITION BETWEEN MATERIALS OR COLORS, PROVIDE CLEAN, STRAIGHT LINES AND FINISH EDGES USING MANUFACTURER’S STANDARD TRIM UNLESS NOTED OTHERWISE.
8. ENSURE ALL EQUIPMENT IS FULLY OPERATIONAL AND TESTED PRIOR TO FINAL INSPECTION.
REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.
EQUIPMENT AND FINISH GENERAL NOTES
WALL
PAINT
CEILING
PAINT
BACK
SPLASH
COUNTERTOP
UPPER &
BASE
CABINET
SG
WALNUT
HARD WOOD
WHITE
Easy to install, clean
and maintain
BLEACHED
NUWOOD
GRIGIO ANTRIM -
J0752
PLYWOOD GRAY MATTE SURFACE, ANTI FINGERPRINT
577 SODALITE
TACTILE
INFUSION
GT422
DURACOLOR
TRICOR PREMIUM
NYLON
RECTANGULAR TUBE PROFILE – IDEAL
FOR MODERN BAFFLE CEILING SYSTEMS.
LIGHTWEIGHT, DURABLE, AND SLEEK —
PERFECT FOR CREATING CLEAN LINEAR
CEILING DESIGNS WITH ARCHITECTURAL
IMPACT.
BC BAFFLE CEILING
SMART GLASS
9/16" THICK TEMPERED SAFETY
LAMINATED LC PRIVACY GLASS
SILVER
9/16" THICK
TEMPERED GLASS 27'*9' GLASS TRANSPARENCY
ARMSTRONGCEILINGS LINEAR ACOUSTICAL PANELS AS IN PLAN STAINLESS STEEL SILVER
1'-5" 4'-0" 4'-0" 4'-0" 3'-5"
3'-9" 2'-0" 6'-0" 2'-0" 6'-0" 2'-0" 3'-9"
C.H.= 8'-6" 1'-11" 3'-8" 4'-0" 4'-0" 4'-0" 1'-5"
6'-6" 1'-8" 1'-8" 6'-6" 1'-1" 2'-0" 2'-0" 2'-0" 1'-9" 2'-0" 2'-0" 1'-5" 6" 5'-9"
C.H.= 8'-6"
C.H.= 8'-11"
1'-6" 4'-7" 4'-7"1'-6" 2'-0" 4'-0" 2'-0" 4'-0" 2'-0" 4'-7" 4'-7" 1'-6" 1'-6"
1'-7" 6"1'-7" 1'-7" 1'-7" 6"
A8.0
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT NORTH
-4
Scale: 1/4" = 1'-0"
TRAINING ROOM - REFLECTED CEILING PLAN -2
Scale: 1/4" = 1'-0"
TRAINING ROOM - CONSTRUCTION PLAN
-1
Scale: 1/4" = 1'-0"
BREAK ROOM - CONSTRUCTION PLAN
CONSTRUCTION PLAN LEGEND
C.H.= # - # CEILING HEIGHT
KEY PLAN
(N) FLOOR TRANSITION
(E) WALLS TO REMAIN
AREA OF WORK
(N) CONCRETE EPOXY FLOORING
(N) RECESSED LED 2'X4' LIGHTING
1. PATCH, AND REPAIR ALL DAMAGED FLOORING SURFACES AS NECESSARY. ENSURE THE SUBSTRATE IS PROPERLY PREPARED TO RECEIVE THE NEW FLOORING FINISH. ALL REPAIRS SHALL PROVIDE A SMOOTH, STABLE, AND EVEN SURFACE SUITABLE FOR THE SPECIFIED FLOORING INSTALLATION. FURNISH AND INSTALL NEW FLOORING IN FULL COMPLIANCE WITH THE FINISH SCHEDULE AND MANUFACTURER’S SPECIFICATIONS.
2. PATCH AND REPAIR THE EXISTING BASE CEILING AS REQUIRED. ENSURE THE SURFACE IS PROPERLY PREPARED TO RECEIVE THE NEW CEILING. FURNISH AND INSTALL NEW GYPSUM BOARD, CEILING IN ACCORDANCE WITH RCP PLANS.
3. FURNISH AND INSTALL ALL NEW ELECTRICAL WIRING, AND CONDUIT AS PER APPROVED ELECTRICAL AND CONSTRUCTION PLANS. ENSURE FULL COMPLIANCE WITH LOCAL CODES, NEC STANDARDS, AND SAFETY REGULATIONS. SAFELY DISCONNECT, PROTECT, AND REMOVE EXISTING SYSTEMS AS REQUIRED BEFORE INSTALLATION OR RELOCATION. COORDINATE WITH ALL TRADES TO AVOID INTERFERENCES AND ENSURE SYSTEM INTEGRITY.
4. FURNISH AND INSTALL ALL BUILT- IN STORAGE UNITS AND CABINETS, SHELVING AND COUNTERTOP, ENSURING PROPER ANCHORAGE, ALIGNMENT, AND LOAD-BEARING CAPACITY PER SPECIFICATIONS.
5. CONSTRUCT ALL NEW INTERIOR DRY WALLS INCLUDING FULL HEIGHT GLASS PARTITIONS AS INDICATED WITH HATCH PATTERNS, PER CONSTRUCTION. ENSURE ALL WORK MEETS DESIGN SPECIFICATIONS AND CODE REQUIREMENTS.
6. PATCH AND REPAIR ALL DAMAGED WALL AREAS SURROUNDING THE DOOR OPENINGS. ENSURE SURFACES ARE PROPERLY PREPARED TO RECEIVE NEW DOORS. FURNISH AND INSTALL NEW DOORS AS PER THE DOOR SCHEDULE AND MANUFACTURER'S SPECIFICATIONS.
7. FURNISH AND INSTALL ALL ELECTRICAL FIXTURES AND RELATED MISCELLANEOUS COMPONENTS AS INDICATED IN THE REFLECTED CEILING PLAN (RCP) AND ELECTRICAL PLANS. ENSURE PROPER
INSTALLATION, ALIGNMENT, AND FUNCTIONALITY IN COMPLIANCE WITH APPLICABLE CODES AND SPECIFICATIONS.
8. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL FINISH. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
9. FURNISH AND INSTALL ALL NEW PIPING AND MECHANICAL EQUIPMENT FOR KITCHENETTE AS SPECIFIED IN THE MECHANICAL AND CONSTRUCTION PLANS. ENSURE ALL WORK COMPLIES WITH APPLICABLE CODES, STANDARDS, AND PROJECT REQUIREMENTS. COORDINATE CLOSELY WITH MECHANICAL ENGINEERS TO
ENSURE THE PROPER DISCONNECTION, RELOCATION, AND RECONNECTION OF EXISTING SYSTEMS, MINIMIZING DISRUPTION TO OPERATIONS AND MAINTAINING SYSTEM INTEGRITY.
CONSTRUCTION PLAN NOTES #
CONSTRUCTION KEY NOTES #
1. (E) VERTICAL DUCT - TO COVER WITH STEEL CYLINDER CABINET PER EQUIPMENT SCHEDULE
2. (E) PRINTER - TO REWORK
3. (N) 85" WALL-MOUNTED TV - TO INSTALL
4. (N) CORK BOARD - TO INSTALL
5. (E) TV MONITOR TO BE CEILING-HUNG IF REQUIRED BY CLIENT
6. (N) 75" WALL-MOUNTED TV - TO INSTALL
7. (N) WHITE BOARD WALL MOUNTED - TO INSTALL
8. (N) SPACE FOR MICROWAVE
9. (N) SPACE FOR COFFEE MAKER
10. (N) SPACE FOR OVEN
11. (N) SPACE FOR BUILT-IN REFRIGERATOR AND FREEZER
12. (N) PANTRY
13. (N) FIRE EXTINGUISHER - TO INSTALL
14. (N) KEY CABINET LOCK TO INSTALL
15. (N) FULL HEIGHT STORAGE CABINET
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A8.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
CONST. RCP PLAN NOTES
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL TILE AND GRID PER CONSTRUCTION PLAN, ENSURE ALL CEILING HEIGHTS,
MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. (AS NEEDED)
#
-3
Scale: 1/4" = 1'-0"
BREAK ROOM - REFLECTED CEILING PLAN
1 4
1 4
4 4
4 2
2 ALIGN ALIGN ALIGN
ALIGN
ALIGN
ALIGN
1 2
3 4
4 RCP PLAN LEGEND
(N) TILE AND GRID 2'X4'
(N) LED CEILING MOUNTED LIGHT
ALIGN
ALIGN ALIGN ALIGN ALIGN
9 8 10 8 11 12
6 7
4 11 8
BREAK ROOM & TRAINING ROOM CONSTRUCTION
& RCP PLANS |MAINTENANCE BUILDING
2ND FLOOR
1ST FLOOR
14 13
15 15
(N) NEW WALLS TO INSTALL
5 6
5 ALIGN
25'-7" 8'-6"
1'-9" 4" 2'-3
1 2" 3'-4" 2'-0" 8'-6" 6" 3'-0" 5'-6"
2'-6" 2'-6" 2'-6" 5'-11" 2'-6"
25'-10"
1"
1" 1'-4" 3'-0" 1'-4" 1'-7" 1'-9"2'-6" 2'-6"
wall-mounted
CL
85" TV
board board 4" 2'-6
1 2" 1
1 2" 2'-0" 3'-0" 6"
CL 8'-6"
1'-3"
2'-1"
16'-9" 14'-8" 3'-41 5 2" 1
2" 6'-2" 5" 3'-412" 5
1 10" 2" CL
16'-7" 8'-6" 5'-4" 4'-0" 5'-4" 2'-1" 16'-9"
1"
2'-6" 1'-4" 3'-0" 1'-4" 2'-6" 2'-6" 2'-6" 1"
4'-0" 15'-7" 6'-0" 11'-5" 6" 17'-0" 28'-11"
11'-6"
2'-0" 7'-6" 2'-0"
7" 3'-4" 5'-8"
7'-8 1/2" 3'-2" 14'-8 1/2"
25'-7" 5'-4"
11'-6" 2'-10" 4'-3" 8'-6" 5'-8" 2'-10" 1'-5"
11'-6" 2'-10" 4'-3" 8'-6" 5'-8" 2'-10" 1'-5"
1" 2'-8" 1" 8'-7" 11'-5" 2'-10" 4'-3" 8'-6" 5'-8" 2'-10" 1'-5"
SCHEDULE BOARD
11'-5" 2'-10" 4'-3" 8'-6" 5'-8" 2'-10" 1'-5" 7'-1" 1'-5" A8.1
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -4
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "E"
-1
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "A"
-3
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "C"
-2
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "B"
-A
Scale: 1/4" = 1'-0"
BREAK ROOM - DIMENSION PLAN
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
NORTH
CONSTRUCTION PLAN LEGEND
KEY PLAN
(E) WALLS TO REMAIN
AREA OF WORK
(N) NEW WALLS TO INSTALL
(N) CONCRETE EPOXY FLOORING
DIMENSION PLAN NOTES
CONSTRUCTION KEY NOTES #
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A8.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
C
A
D B
6 7 8 6 9 10
5 4
4 3
2 1
4 3 4
11 4
11 6
6 7
8 10 9
1ST FLOOR
BREAK ROOM DIMENSION PLAN & WALL VIEWS
|MAINTENANCE BUILDING
-5
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "E"
-6
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "F"
-7
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "G"
-8
Scale: 1/4" = 1'-0"
BREAK ROOM - WALL VIEW "H"
E
G
H F
1. (E) VERTICAL DUCT - TO COVER WITH STEEL CYLINDER CABINET PER EQUIPMENT SCHEDULE
2. (E) PRINTER - TO REWORK
3. (N) 85" WALL-MOUNTED TV - TO INSTALL
4. (N) CORK BOARD - TO INSTALL
5. (E) TV MONITOR TO BE CEILING-HUNG IF REQUIRED BY CLIENT
6. (N) SPACE FOR MICROWAVE
7. (N) SPACE FOR COFFEE MAKER
8. (N) SPACE FOR OVEN
9. (N) SPACE FOR BUILT-IN REFRIGERATOR AND FREEZER
10. (N) PANTRY
11. (N) FIRE EXTINGUISHER - TO INSTALL
12. (N) KEY CABINET LOCK TO INSTALL
13. (N) FULL HEIGHT STORAGE CABINET
1 2
2 2 2
13 12 13
13 12
13 5
5'-4" 9'-0" 1'-0" 2'-8"
4'-8" 7'-8" 4'-8"
17'-0"
5'-8" 3'-4"
3'-6" 10'-0" 3'-6" 2'-0" 25'-2 1/2" 2'-0 1/2" 29'-2 1/2" 17'-0"
2'-7 1/2" 4'-10 1/2" 5'-11" 2'-6"
4'-8" 7'-8" 4'-8" 4'-0" 9'-0" 3'-0"
2'-6" 2'-6"
17'-0"
2'-6" 2'-0"
1" 5'-6 1/2" 2'-10" 7'-0" 4" 1'-8"
EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ.
1" 1" 1" 4'-2" 4'-6" 4"
A8.2
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -A
Scale: 1/4" = 1'-0"
TRAINING ROOM - DIMENSION PLAN
-1
Scale: 1/4" = 1'-0"
TRAINING ROOM - WALL VIEW A
-2
Scale: 1/4" = 1'-0"
TRAINING ROOM - WALL VIEW B
A
B
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
NORTH
CONSTRUCTION PLAN LEGEND
KEY PLAN
(E) WALLS TO REMAIN
AREA OF WORK
(N) NEW WALLS TO INSTALL
(N) CONCRETE EPOXY FLOORING
DIMENSION PLAN NOTES
CONSTRUCTION KEY NOTES #
1. (E) VERTICAL DUCT - TO COVER WITH STEEL CYLINDER CABINET PER EQUIPMENT SCHEDULE
2. (E) PRINTER - TO REWORK
3. (N) 85" WALL-MOUNTED TV
4. (N) CORK BOARD
5. (N) 75" WALL-MOUNTED TV
6. (N) WHITE BOARD WALL MOUNTED
7. (N) SPACE FOR MICROWAVE
8. (N) SPACE FOR COFFEE MAKER
9. (N) SPACE FOR OVEN
10. (N) SPACE FOR REFRIGERATOR AND FREEZER
11. (N) PANTRY
NOTES:
1. FOR EQUIPMENT AND FINISH SCHEDULE, SEE SHEET A8.3
2. FOR WINDOW AND DOOR SCHEDULE, SEE SHEET A9.0
4 5
5 6
7 10
10 7
2ND FLOOR
TRAINING ROOM DIMENSION PLAN & WALL
VIEWS |MAINTENANCE BUILDING
A8.3
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT
CYLINDER
CABINET CADISCHMDA PER PLAN YELLOW METAL WITH
POWDER COATED VW
65" TV
MONITOR
PERFORATED
SHEETS
R15T20
YELLOW
ID NAME IMAGE MANUFACTURE DIMENSIONS MATERIAL/FINISH COLOR
EQUIPMENT SCHEDULE
ONE
COMPARTMENT
SINK
OS
Built-In
Wall Oven
MW
TV
REMARK
30" L x 22" W x 9" H Heavy-Duty Stainless Steel
Durable, rust resistance, and easy cleaning.
29-3/4" W x 24-15/35" D x 30" H LG WCES6428F Stainless Steel Silver LG - 1.7 Cu. Ft. Convection Built-In Microwave with Sensor Cooking and Air Fry - Stainless Steel
VEVOR Stainless Steel Silver
MODEL
1. ALL EQUIPMENT AND FINISHES SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND APPLICABLE CODES.
2. CONFIRM ALL EQUIPMENT LOCATIONS, CONNECTIONS, AND CLEARANCES WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING PLANS PRIOR TO INSTALLATION.
3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO ORDERING OR INSTALLING ANY EQUIPMENT OR FINISHES.
4. ALL FINISHES TO BE INSTALLED WITH UNIFORM COLOR, TEXTURE, AND PATTERN ALIGNMENT, AS PER APPROVED SAMPLE.
5. ALL MATERIALS SHALL BE NEW, OF COMMERCIAL GRADE, AND FREE OF DEFECTS.
6. SUBMITTALS FOR ALL FINISHES AND EQUIPMENT SHALL BE PROVIDED FOR ARCHITECT’S REVIEW AND APPROVAL PRIOR TO PROCUREMENT.
7. WHERE FINISHES TRANSITION BETWEEN MATERIALS OR COLORS, PROVIDE CLEAN, STRAIGHT LINES AND FINISH EDGES USING MANUFACTURER’S STANDARD TRIM UNLESS NOTED OTHERWISE.
8. ENSURE ALL EQUIPMENT IS FULLY OPERATIONAL AND TESTED PRIOR TO FINAL INSPECTION.
REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.
EQUIPMENT AND FINISH GENERAL NOTES
SAMSUNG THE FRAME PRO LS03FW
NEO QLED 4K (WxHxD)
57.4" x 32.9" x 1"
BLACK
Modern Frame Design with Wireless One Connect
Art Mode
Artful Picture Quality with Neo QLED
Samsung Vision AI
DOUBLE
COMPARTMENT
SINK
33" L x 22" W x 9" H Heavy-Duty Stainless Steel
VEVOR Durable, rust resistance, and easy cleaning. Stainless Steel Silver Built-In
Microwave
OV LG WSES4728F 29-3/4" W x 24-15/35" D x 43-7/8" H Stainless Steel Silver Electric Single Oven with Convection Bake and Auto Shut Off
RF REFRIGERATOR
(WxHxD) LFCS22520S 29 2/2" x 73 1/8" x 26 5/8" LG
Stainless Steel Silver
22 cu. ft. 30-inch Wide French Door Refrigerator -
Stainless Steel
DS
KF KITCHEN
FAUCET KOHLER 18.07"(H) VIBRANT STAINLESS
Covered under Kohler's limited lifetime warranty
Faucet body constructed of metal
Single hole mounting type
Deck mounted faucet installs directly to sink or countertop Includes ceramic disc cartridge
Complies with ADA standards
K-28269 SILVER
CM Built-In
Coffee Maker
ADA Compliant
Fisher and Paykel EB30PSX1 29-13/16" W x 19-1/8" D x 18-1/2" H MODEL NEEDS TBC Stainless Steel Silver
FINISH SCHEDULE
ID NAME IMAGE MFG. LOCATION MATERIAL COLOR
CF
WPT
CPT
MODEL FINISH REMARK
CONCRETE CONCRETE
CRAFT STAINED
THROUGHOUT
ALL THE
FLOORING U.N.O
MATTE
EPOXY
LIGHT
- GRAY/
Per
Manufacture
Specification
SHERWIN
WILLIAMS
SHERWIN
WILLIAMS
THROUGHOUT
ALL THE
WALLS U.N.O
THROUGHOUT
ALL THE
CEILING U.N.O
-
-
WATER- BASED
WATER- BASED
EGGSHELL
FLAT
ALABASTER
SW 7008
PURE WHITE
SW 7005
1 Coat primer, as
needed to full cover
1 Coat primer, as
needed to full cover
DIM.
-
-
-
BS BACK SPLASH IN
THE KITCHEN
CT
UB-C
CORIAN COUNTERTOP IN
THE KITCHENETTE
LEICHTCA MATTE
UPPER AND BASE
CABINET IN THE
KITCHENETTE
CORIAN CALACATTA
GREIGE
CALACATTA
GREIGE
Hygienic & Easy to Clean
Seamless
Repairable & Renewable
Sustainable
Hygienic & Easy to Clean
Seamless
Repairable & Renewable
Sustainable
CORIAN SOLID BEIGE AND GRAY
SURFACE
GLOSS
CORIAN SOLID
SURFACE
GLOSS BEIGE AND GRAY
-
PER PLAN
PER PLAN
GRIGIO ANTRIM - J0752 MATTE SURFACE, ANTI FINGERPRINT PLYWOOD GRAY NORTH
KEY PLAN
2ND FLOOR
1ST FLOOR
BREAK ROOM & TRAINING ROOM FINISH & EQP.
SCHEDULES |MAINTENANCE BUILDING
RH HOOK LIBERTY HARDWARE B45006J-BSN-C7 Stainless Steel Silver
KC KEY CABINET ULINE
THICKNESS:
Body: 22 gauge
Door: 20 gauge Keyed Lock, 30 Key Powder coat finish
Heavy-duty 22-gauge welded-steel lockable key cabinet.
Includes "Out Key" tags to identify who has keys.
Numbered tag key holders easily identify keys.
Mounting hardware included.
CT
COUNTERTOP IN
OPERATOR ROOM
BREAK ROM
KATOM - Advance Tabco VCTC-240
STAINLESS STEEL
STAINLESS STEEL SILVER
SATIN FINISH
3'-4" 7'-2"
3'-6" 7'-2"
3'-4" 3'-0" 8'-0"
6'-0"
3'-4" 7'-2"3'-4" 7'-2"2'-10" 7'-2"
8'-0"
1'-0" 5'-4" 1'-0" 8'-0"
DOOR & WINDOW SCHEDULES &
VERTICAL WALL DETAIL
- DOOR TYPES 1
A9.0
- DOOR SCHEDULE 2
GENERAL WINDOW & DOOR NOTES
CONSTRUCTION PLAN LEGEND
#
Door Schedule
Count.
DOOR DESCRIPTION
Door Finish Frame Material
ID MATERIAL
D3 4
D4
Width Height Manufacture Comments
1 DOOR SCHEDULE
1. ALL DOORS AND WINDOWS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS AND ALL APPLICABLE CODES AND REGULATIONS. VERIFY ALL DIMENSIONS AND OPENING CONDITIONS IN THE FIELD PRIOR TO FABRICATION AND INSTALLATION.
2. ALL HARDWARE, GLAZING, SEALS, AND ACCESSORIES SHALL BE PROVIDED AS SPECIFIED IN THE DOOR AND WINDOW SCHEDULE AND DETAILS.
3. COORDINATE WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND FINISH PLANS TO AVOID CONFLICTS.
4. PROVIDE SHIMS, INSULATION, AND WEATHERPROOFING AS REQUIRED FOR PROPER FIT AND PERFORMANCE.
5. PROVIDE FIRE-RATED ASSEMBLIES WHERE REQUIRED BY CODE.
6. ENSURE SMOOTH OPERATION, PROPER ALIGNMENT, AND FULL FUNCTIONALITY OF ALL DOORS AND WINDOWS UPON INSTALLATION.
7. ENSURE COMPLIANCE WITH ADA REQUIREMENTS FOR CLEARANCES, THRESHOLDS, AND HARDWARE.
8. PROTECT ALL UNITS FROM DAMAGE DURING CONSTRUCTION. DAMAGED ITEMS SHALL BE REPLACED AT NO ADDITIONAL COST TO THE OWNER.
DOOR SCHEDULE
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT 3'-4" 7'-2" SOLID WOOD WOOD TRUDOOR PAINT GRADE PRIMED HARDBOARD SOLID CORE WOOD DOOR 7'-6" SOLID WOOD WOOD POCKET DOOR
D1
D2
2 6' 6' GLASS FACTORY FINISH ALUMINUM
1 3'-4" 3' GLASS STAINLESS STEEL
AUTOMATIC SLIDING DOOR OPERATOR
D5 2 3'- 4" 7'-2"
GLASS
FRAME LESS GLASS
D6 1
SMART GLASS
3'- 4" 7'-2"
3'- 6" SARTODOORS
FRAME LESS GLASS
INNOVATIVEGLASS CONFERENCE ROOM
ROOF DECK
BOON EDAM
Location
- SKYFOLD VERTICAL ACOUSTIC WALL 3
D7 2 2'- 10" 7'-2" SOLID WOOD WOOD TRUDOOR PAINT GRADE PRIMED HARDBOARD SOLID CORE WOOD DOOR D8 1 ADMIN BUILDING-MAIN ENTRANCE
MAINTENANCE – 2ND FLOOR RESTROOMS
TRAINING ROOM
TRAINING ROOM & CONFERENCE ROOM
DISPATCH
DRIVERS LOUNGE/VESTIBULE
-
-
AUTOMATIC SLIDING
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
FACTORY FINISH
8' 8' GLASS SAFETY GLASS FRAME LESS GLASS RIOT GLASS
RIOT GLASS
RIOT GLASS
SWING GLASS GATE WITH ACCESS CONTROL/ONE-WAY OPERATION
CERAMIC WALL TILE
BASE WALL TILE
SETTING MATERIAL
5/8" CEMENT BACKER BOARD,
INSTALL TILE PLUMB, SMOOTH AND TRUE
SCHLUTER-DILEX-AHK 3/8"R
CERAMIC FLOOR TILE
1/4" THICK MAX. SETTING BED, TYP.
STEEL STUDS @ 16" 0.C.
SKIM COAT, FIBER MESH TAPE,
SETTING MATERIAL AND GALV.
SCREWS @ 8" O.C. OR FULL
DEPTH MORTAR BED
BLOCK ALL EDGES
SETTING MATERIAL
BASE PLATE
SUPPORT FRAMING FOR
ATTACHMENT OF FIXTURES
CERAMIC TILE
5/8" CEMENT BACKER BOARD
MAX. 1/2" HIGH MARBLE
THRESHOLD
DOOR, PER SCHEDULE
THINSET CERAMIC TILE
JAMB BEYOND
CARPET, WHERE OCCURS
2:1 SLOPE
716
" MAX. AT COMPRESSED CARPET BELOW THRESHOLD
CONCRETE FINISH
DOOR AND FRAME PER
SCHEDULE
CARPET FINISH WHERE
OCCURS
THRESHOLD PER SPECS.
1:2 SLOPE
CONCRETE FINISH
DOOR AND FRAME PER
SCHEDULE
CARPET FINISH WHERE
OCCURS
THRESHOLD PER SPECS.
1:2 SLOPE
VINYL REDUCER- JOHNSONITE
SSR-XX-B, BINDER BAR
EDGING
RESILIENT FLOORING (VCT,
SHEET VINYL, STATIC
DISSIPATIVE TILE, EPOXY
FLOORING)
SEALED CONCRETE
* TYPES OF RESILIENT FLOORING TO INCLUDE:
- VCT
- STATIC DISSIPATIVE TILE
- EPOXY FLOORING
CARPET
VINYL "CARPET TO RESILIENT
FLOORING" ADAPTOR -
JOHNSONITE
RESILIENT FLOORING
ADAPTOR JOHNSONITE
CTA-XX-N
RESILIENT FLOORING*
RESILIENT FLOORING*
* TYPES OF RESILIENT FLOORING TO INCLUDE:
- VCT
- STATIC DISSIPATIVE TILE
- EPOXY FLOORING
BATT INSULATION-WHERE
OCCURS
ST. STUD PER STRUCTURE PLAN
CEMENT BACKER BOARD
WALL PER FINISH SCHEDULE
INSULATION WHERE OCCURS
WD. DOOR FRAME PER
SCHEDULE
DOOR PER SCHEDULE
5/8" TYPE 'X' GYPSUM BOARD
EACH SIDE OVER ST. STUD
SEE STUD TABLE FOR SIZE
AND SPACING
WD. HEADER / JAMB @ HEAD
/JAMB. PER-STRUCTURE
TILE
1/4" THICK MAX. SETTING BED, TYP.
TILE BASE
3/8"R
5/8" CEMENT BACKER BOARD, INSTALL TILE
PLUMB, SMOOTH AND TRUE
WALL FINISH MATERIAL, SEE ROOM FINISH SCHEDULE ON A01.1 DETAILS A9.1
-7
Scale:1:4
RESTROOM COVE BASE DETAIL
-4
Scale:1:4
RESTROOM DRY WALL TILE DETAIL
-3
Scale: 1:4
TRANSIT. RESILIENT TO CONCRETE
-1
Scale: 1:4
TRANSITION DETIALS @ DOOR
-8
Scale: 1:4
BASIC WALL @ CEMENT BOARD
-2
Scale: 1:4
TRANSIT. CARPET TO CONCRETE
-6
Scale: 1:4
TRANSIT. CARPET TO CERAMIC
-5
Scale: 1:4
TRANSIT. RESILIENT TO CARPET
-9
Scale: 1:4
TRANSIT. RESILIENT TO RESILIENT
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -11
Scale: 1:5
INTERIOR DOOR HEAD/ JAMB
-10
Scale: 1:4
RESTROOM COVE BASE DETAIL
ELECTRICAL METALLIC TUBING
TO 7'-8"
TO 5'-10"
COMPRESSION STRUT INSTALLATION
CONDUIT CAN BE FLATTENED AT THE ENDS AND CONNECTED TO THE T-BAR MAIN RUNNER WITH ONE #10 SHEET METAL SCREW.
TO 9'-9"
THE FOLLOWING SPANS ARE BASED UPON STUDS HAVING A 1-5/8" LEG WITH A 3/8" RETURN. DOUBLE STUDS ARE CONNECTED TOGETHER IN THE SHAPE OF A , WITH ONE #6 SHEET METAL SCREW AT 16" O.C.. ATTACH THE METAL STUD TO THE T-BAR MAIN RUNNER WITH TWO #8 SCREWS. SEE DETAILS FOR ATTACHMENT TO STRUCTURE ABOVE.
DBL 1-5/8 X 20 GA
STEEL STUDS
3-5/8" X 20 GA. STUDS- SCREWED W/ 7/16" 9 GA. FRAMING SCREWS @ 24" O.C. STAGGERED- SANDWICH MAIN RUNNER BACK. & ATTACH W (3) 7/16" FRAMING SCREWS.
PRE-MANUFACTURED STRUTS MAY ONLY BE USED IF ENGINEERING IS APPROVED BY THE BUILDING DEPARTMENT. GC TO SUBMIT FOR APPROVAL.
METAL STUDS:
MANUFACTURED STRUTS:
1-5/8 X 20 GA.
1/2"
3/4"
1"
TO 15'-0"
TO 15'-0"
TO 12'-0"
MAIN RUNNER
#12 VERTICAL HANGER WIRE INSIDE OF
CONDUIT, TIE TO STRUCTURE PER
DETAILS.
UNDERSIDE OF FLOOR OR
ROOF STRUCTURE ABOVE.
SEE SCHEDULE FOR MAXIMUM
HEIGHT.
DRILL 5/32" DIAMETER HOLE
AND INSTALL 1/8" DIAMETER
BOLT AND LOCKING NUT.
TUBES SHALL LAP 4"
MINIMUM.
SUSPENDED CEILING SYSTEM,
SEE REFLECTED CEILING PLAN.
CROSS RUNNER.
SLOT END OF TUBE TO
FIT
OVER TOP OF MAIN
RUNNER
SUSPENDED CEILING SYSTEM, SEE
REFLECTED CEILING PLAN FOR
SPECIFICATIONS.
ICC-ES # ESR-2282, OR 1222, OR 1308
CIRCLE INDICATES REQUIRED
LOCATION OF COMPRESSION
STRUTS. SEE BELOW.
20GA. MTL. STD COMPRESSION STRUT @ EA. SET OF BRACING WIRES W/(2) #8 SHEET MTL. SCREWS TO THE GRID, SPAN PER TABLE ABOVE.
SUSPENDED CEILING
SYSTEM. SEE CEILING PLAN.
(2) STUD ORIENTATION
#10 BRACING WIRE W/4 TIGHT TURNS IN 1 1/2" EACH END. SPLAY
WIRE BRACING IN CLUSTERS OF FOUR WIRES ATTACHED TO MAIN RUNNER WITHIN 2" OF A CROSS TEE SECTION. OCCUR WHEN
CEILING AREA EXCEEDS 1000 SF
CROSS
RUNNER
LATERAL FORCE BRACING: A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. LATERAL FORCE BRACING SHALL BE 12 FEET ON CENTER (MAXIMUM) AND BEGIN NO FARTHER THAN 6 FEET FROM WALLS. LATERAL FORCE BRACING MEMBERS MUST BE SPACED A MINIMUM OF 6" FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT IS NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZ. FORCES. BRACING WIRES
MUST BE ATTACHED TO THE GRID AND TO THE STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT A DESIGN LOAD OF NOT LESS THAN 200 POUNDS OR THE ACTUAL LOADS, WHICHEVER IS GREATER, WITH A SAFETY FACTOR OF 2.
ATTACHED
UNATTACHED UNATTACHED ATTACHED
2-1/2" X 20 GA TO 13'-6"
DBL 2-1/2" X 20 GA CEILING SYSTEMS ARE TO BE
ATTACHED ONLY AT 2 ADJACENT WALLS
OR SOFFITS
LARR # 24299
#12 VERTICAL HANGER WIRE @ 4'-0" O.C. EACH WAY (4' O.C. AT MAIN RUNNER) MINIMUM 3 TIGHT TURNS IN 1-1/2" BOTH ENDS TYPICAL #12 VERTICAL HANGER WIRE @ 4'-0"
O.C. EACH WAY (4' O.C. AT MAIN
RUNNER) MINIMUM 3 TIGHT TURNS
IN 1-1/2" BOTH ENDS TYPICAL
THE FOLLOWING INSTALLATION DETAILS ARE TO BE CONSIDERED TO BE COMPLYING WITH THE ABOVE REQUIREMENTS.
NOTES:
1. WHERE THE ROOF SYSTEM IS COMPOSED OF WOOD BEAMS, PURLINS, AND SUB-PURLINS, THE 2 X 4 SUB-PURLINS ARE NOT TO BE CONSIDERED AS STRUCTURAL MEMBERS SUPPORTING THE ROOF.
2. CEILING SUSPENSION SYSTEM SHALL COMPLY WITH 803.9 AND 2506.2.1. COMPONENTS SHALL BE ASTM "HEAVY DUTY" CLASS.
3. THE COMPRESSION STRUT SHALL BE VERTICAL, AND SHALL NOT HANG MORE THAN 1 IN 6 OUT-OF-PLUMB.
EMT:
ACOUSTICAL CEILING SUSPENSION SYSTEM
LATERAL FORCE BRACING AND SUSPENSION
LIGHT
FIXTURE
FIRE
SPRINKLER
* = 45°
EMT SLEEVE
#10 BRACING WIRES W/4 TIGHT TURNS IN 1 1/2"
EACH END. SPLAY WIRE BRACING IN CLUSTERS
OF FOUR WIRES ATTACHED TO MAIN RUNNER
WITHIN 2" OF A CROSS TEE SECTION. OCCUR
WHEN CEILING AREA EXCEEDS 1000 SF
* = 45°
12'-0" O.C. TYP.
12'-0" O.C. TYP.
6'-0" MAX.
3 -
5B
-
5A
-
11 -
NOTES:
1. STRUTS OTHER THAN EMT MAY REQUIRE ENGINEERING CALCULATIONS.
2. STRUTS OVER 12 FEET MAY REQUIRE ENGINEERING CALCULATIONS. LONG AND HEAVY STRUTS PRESENT ADDITIONAL SEISMIC HAZARD; THEREFORE, THE APPLICANT MAY BE REQUIRED TO PROVIDE CALCULATIONS SHOWING THAT ADDITIONAL STRUT ELEMENTS SUCH AS MAIN RUNNERS, VERTICAL AND SPLAYED WIRED, ETC.
ICC ER-4071
12 -
CEILING GRID
SUSPENDED
LIGHT FIXTURE
(LESS THAN 56 LBS.)
LATERAL FORCE BRACING MEMBERS MUST BE
SPACED A MINIMUM OF 6" FROM ALL
HORIZONTAL PIPING OR DUCT WORK THAT IS
NOT PROVIDED WITH BRACING RESTRAINTS FOR
HORIZ. FORCES. BRACING WIRES MUST BE
ATTACHED TO THE GRID AND TO THE
STRUCTURE IN SUCH A MANNER THAT THEY CAN
SUPPORTA DESIGN LOAD OF NOT LESS THAN 200
POUNDS OR THE ACTUAL LOADS, WHICHEVER IS
GREATER, WITH A SAFETY FACTOR OF 2.
PROVIDE MINIMUM OF 2 SCREWS
AT OPPOSIT CORNERS OF
SUPPORT WIRES, OR SCREW ON
T-BAR SAFETY CLIPS AT SIDES OR
ENDS.
TWO (2) NO. 12 GAUGE WIRES MUST BE
SECURED FROM LIGHT & MECHANICAL
FIXTURES AT OPPOSING CORNERS
ALONG THE FIXTURE'S DIAGONAL. WIRES
MAY BE SLACK.
WHEN HEAVY-DUTY
CEILING SYSTEMS ARE
USED, SUPPLEMENTAL
HANGERS ARE NOT
REQUIRED IF A 48"
MODULAR HANGER
PATTERN IS FOLLOWED.
HEAVY-DUTY CEILING
SYSTEMS
o 45 45
o o
45 o
45 NOTES:
1. ALL HANGERS & SUPPORTS TO BE ATTACHED WITH 4 TURNS IN 1 1/2" (TYP.)
2. SUPPORT EACH LIGHT FIXTURE INDEPENDENTLY OF CEILING GRID WITH 1-#12 WIRE AT TWO CORNERS DIAGONALLY ACROSS FROM ONE ANOTHER.
3. ALL MAIN AND CROSS TEES, THEIR SPLICES AND INTERSECTING CONNECTIONS SHALL BE ADEQUATE TO RESIST 72 lbs. IN TENSION.
4. INSTALL SYSTEM PER: SECTION 9.6 OF ASCE 7
12 GA. SPLAYED WIRE BRACING PERPENDICULAR
TO EACH RUNNER 8" MAX FROM EACH END OR
BREAK TO PREVENT SPREADING
EMT COMPRESSION STRUT, 12' O.C. MAX., 6' @ CEILING
PERIMETER, NOT TO EXCEED 1:6 OUT OF
PLUMB:INSTALL STRUT AT EACH JUNCTIONWITH
SPLAY WIRES. SEE SCHEDULE
12 GA. HORIZONTAL SEISMIC RESTRAINTS SPLAYED 90° FROM
EACH OTHER @ 12'-0" O.C. BOTH WAYS TO WITHIN 6'-0" OF
WALLS
12 GA. VERTICAL HANGER @ 4'-0" O.C., ATTACHED TO
TRAPEZE @ OBSTRUCTIONS. (USE BACK TO BACK 1 1/2" COLD
ROLLED CHANNELS FOR SPANS GREATER THAN 4'-0".)
CROSS RUNNER
MAIN RUNNER
'D'
'C'
'B'
#12 WIRE W/3 FULL TURNS @ RUNNER @ 4'-0" O.C.
CROSS TEE.
SUSPENDED ACOUSTIC CEILING TILE.
ATTACH CEILING GRID TO WALL ANGLE W/ POP RIVET @
TWO ADJACENT WALLS, OPPOSITE ENDS OF GRID TO BE
LOOSE @ WALL AND PROVIDE WITH EITHER 16GA. TIE
WIRE OR STABILIZER BAR IN BETWEEN TO PREVENT
SPREADING.
WALL ANGLE. 2" WIDE MINIMUM
FACE OF WALL.
#8 SCREWS TO SOLID BLOCKING @ STUDS. (TYP.)
2- #12GA. BLACK
SAFETY WIRE FROM
DIAGONAL CORNERS TO
STRUCTURE ABOVE.
MAIN OR CROSS TEE.
LIGHT FIXTURE OR AIR TERMINAL.
(INSTALLATION SIMILAR FOR BOTH.)
#12 WIRE W/ 3 FULL TURNS @
RUNNER @ 4'-0" O.C.
CROSS TEE.
SUSPENDED CEILING TILE.
MAIN TEE.
HILTI CEILING CLIP ANGLE W/ 5/16" EYELET.
ATTACHED TO STRUCTURE ABOVE PER
MANUFACTURER RECOMMENDATIONS
#12 WIRE W/ 4 FULL TURNS @ RUNNER
@ 4'-0" O.C.
8" FROM WALL
TRADE SIZE
ALLOWABLE LENGTH
EMT IMC OR RMC
1/2"
1"
4'-4"
5'-2"
9'-0"
7'-0"
-
1- #12 GA. BLACK SAFETY WIRE ATTACHED
TO OPPOSING CORNERS
ALONG FIXTURE'S DIAGONAL
'A'
13'-2"
9'-10" 10'-5"
8'-6"
6'-6"
5'-7"
3'-10"
3/4"
1 1/4"
1 1/2"
2"
DETAILS
- SUSPENDED CEILINGS/COMPRESSION STRUT 1
A9.2
GENERAL CEILING NOTES
1. SUSPENDED CEILINGS SHALL COMPLY WITH ASTM C 635, ASCE 7-10 SECTION 13.5.6, ASTM C 636, AND ASTM E580, SECTION 5 IN SEISMIC DESIGN CATEGORIES D, E & F.
2. ASCE 7-10 SECTION 13.5.6.2.2 REQUIRES:
A) THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN 2". WHERE PERIMETER SUPPORTING CLIPS ARE USED, THEY SHALL BE QUALIFIED IN ACCORDANCE WITH APPROVED TEST CRITERIA. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE OR CHANNEL. THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE 3/4" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE ANGLE OR CHANNEL.
B) FOR CEILING AREAS EXCEEDING 2500 S.F., A SEISMIC SEPARATION JOINT OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2500 S.F., EACH WITH A RATIO OF THE LONG TO SHORT DIMENSION LESS THAN OR EQUAL 4, SHALL BE PROVIDED UNLESS STRUCTURAL ANALYSIS ARE PERFORMED OF THE CEILING BRACING SYSTEM FOR THE
PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE CEILING PENETRATIONS AND CLOSURE ANGLES OR CHANNELS PROVIDE SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES OR CHANNELS IN ACCORDANCE WITH SECTION 13.5.6.2.2.A AND HORIZONTAL RESTRAINTS OR BRACING.
3. THE SUSPENDED CEILING LATERAL FORCE-BRACING MEMBERS SHALL BE LOCATED A MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR DUCT WORK THAT ARE NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING.
A. UNATTACHED
B. ATTACHED
PROVIDE PERIMETER CLOSURE ANGLE WITH 2"
MIN. LEG. IN EACH ORTHOGONAL DIRECTION,
ONE END OF THE CEILING GRID SHALL BE
ATTACHED TO THE CLOSURE ANGLE AND THE
OTHER END SHALL HAVE A 3/4" CLEARANCE
FROM THE WALL AND SHALL REST UPON AND BE
FREE TO SLIDE UPON THE CLOSURE ANGLE
LATERAL BRACING: 4-12 GA. WIRES SPLAYED 90 DEGREES FROM EACH OTHER SECURED TO MAIN RUNNER WITHIN 2" OF CROSS TEE. THE ANGLE OF THE WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND SHALL BE ATTACHED TO THE ROOF OR FLOOR ABOVE. A METAL STUD STRUT (OR APPROVED ALTERNATE), SECURED TO THE ROOF/FLOOR ABOVE AND WITHIN 2" OF THE SPLAYED WIRE CONNECTION AT THE MAIN RUNNER, SHALL BE SPACED 12'-0" ON CENTER MAXIMUM IN BOTH DIRECTIONS NO FARTHER THAN 6'-0" FROM WALLS. [CISCA] NOTES:
1. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM EA. OTHER AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE CEILING.
2. FOR ROOMS WITH SPAN IN EITHER DIRECTION LESS THAN 25', MAIN RUNNERS AND CROSS RUNNERS MAY BE ATTACHED TO THE PERIMETER OF TWO ADJACENT WALLS WITH 3/8" CLEARANCE BETWEEN THE RUNNERS AND THE OTHER TWO WALLS. WHERE SPAN OF THE CEILING SYSTEM BETWEEN PERIMETER WALLS EXCEED 25' IN BOTH DIRECTIONS, A MINIMUM WALL ANGLE SIZE OF AT LEAST 2" HORIZONTAL LEG SHALL BE USED AT PERIMETER WALLS AND INTERIOR FULL HEIGHT PARTITION. THE FIRST TILE SHALL BE 3/4" CLEAR FROM WALL SURFACE.
3. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND THE CEILING EXCEEDS 4', THE SPACING OF THE VERTICAL HANGERS SHALL NOT EXCEED 2' O.C. ALONG THE ENTIRE LENGTH OF THE MEANS OF EGRESS SERVICING AN OCCUPANT LOAD OF 30 OR MORE, AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES.
4. LATERAL FORCE-BRACING MEMBERS FOR SUSPENDED CEILINGS SHALL BE A MINIMUM OF 6"
FROM ALL HORIZONTAL PIPING OR DUCT WORK NOT PROVIDED WITH BRACING RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES SHALL BE ATTACHED TO THE GRID AND STRUCTURE AND SHALL SUPPORT A DESIGN LOAD THE GREATER OF 200 POUNDS OR THE ACTUAL LOAD, WITH A SAFETY FACTOR OF 2.
5. SUSPENDED CEILING SHALL COMPLY WITH SECTION 803.9 (2010 CBC) AND ASCE SECTION
13.5.8 6. LATERAL BRACING FOR SUSPENDED CEILING MUST BE PROVIDED. WHERE THE CEILING IS
NOT SUPPORTING INTERIOR PARTITIONS, CEILING BRACING SHALL BE PROVIDED BY FOUR NO. 12 GAUGE WIRES SECURED TO THE MAIN RUNNER WITHIN 2 INCHES OF THE CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF CEILING. A STRUT (ADEQUATE TO RESIST
VERTICAL SEISMIC COMPONENT INDUCED BY THE BRACING WIRES) FASTENED TO MAIN
RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED AT 12 FT. ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FT. FROM THE WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. OTHERWISE, PROVIDE A STRUCTURAL DESIGN.
7. IN LIEU OF A 2" WALL ANGLE USE ARMSTRONG SYSTEM PER ASTM C635 AND C636-2007,
ICC-ES APPROVED HEAVY DUTY T-BAR GRID SYSTEM, PRELUDE XL GRID INSTALLED PER ICC-EC REPORT 1308 FOR SEISMIC CATEGORY E.
USE 7/8" WALL ANGLE.
GRID MUST BE ATTACHED TO 2 ADJACENT WALLS. OPPOSITE WALLS REQUIRE ARMSTRONG BERC2 CLIPS
FOLLOW ICC APPROVAL 1308 FOR INSTALLATION DETAILS.
8. PROVIDE SEISMIC SEPARATION FOR CEILING OVER 2500 SF PER ASCE 713.5.6. USE ARMSTRONG "SEISMIC JOINT CLIP"
9. PROVIDE HLD DOWN CLIPS (2) PER CROSS TEE LESS THAN 1 LB PER S.F. - BRACING WIRES @ SUSPENDED CEILINGS 2
ANCHOR WIRES TO
STRUCTURE ABOVE
AT SUSPENDED CEILING: MINIMUM 12
GAGE VERTICAL SUPPORT WIRE AT 4'-0"
O.C. OR 10 GA WIRE AT 5'-0" O.C. W/ (2) 1
1/2" x 9" GA. STAPLES @ LOOP & (1)
ACROSS LAP. 3 FULL TURNS MINIMUM
WITHIN 3" LENGTH. PERIMETER ENDS OF
EACH CROSS RUNNER AND MAIN RUNNER
SHALL BE SUPPORTED A MAXIMUM OF 8"
FROM EACH WALL OR CEILING
DISCONTINUITY
AT OPEN GRID: VERTICAL SUSPENSION
WITH THREADED ROD PER OTHER
DETAILS.
NOTE: - PROVIDE 6" CLEARANCE
AT ALL PIPES & DUCTS, ETC. - BRACING WIRES MUST BE
ATTACHED TO THE GRID AND TO
THE STRUCTURE IN SUCH A
MANNER THAT THER CAN
SUPPORT A DESIGN LOAD OF NOT
LESS THAN 200 POUNDS OR THE
ACTUAL LOADS, WHICHEVER IS
GREATER, WITH A SFETY FACTOR
OF 2.
MAIN RUNNER CROSS RUNNER
- ATTACHED & UNATTAHCED SYS. 3-4
Scale: N.T.S
LIGHTING FIXTURE @ SUSPENDED CEILINGS - SUSPENDED ACOUSTIC CEILING 5 UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS
.\iARCH stamp.jpg
CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT
Women's Restroom
Men's Restroom
RESTROOM
EXERCISE ROOM
RESTROOM
VESTIBULE
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
KEY PLAN
DEMOLITION PLANS | RESTROOMS ADMIN
BUILDING & FUEL ISLAND
A10.0
- -
-2
Scale: 1/2" = 1'-0"
ADMIN. BUILDING @ RESTROOM - DEMOLITION PLAN
-1
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - DEMOLITION PLAN
-3
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - DEMOLITION PLAN
FUEL ISLAND
GYM
ADMIN. BUILDING
1 1
DEMOLITION PLAN LEGEND
(E) WALLS TO DEMOLISH
(E) WALLS TO REMAIN
SCOPE OF WORK
(E) TILE FLOORING TO REMOVE
(E) ITEMS TO DEMOLISH
2 6
6 6
6 1
2 7
7 9 9 9 9
11 11
11 11
8 8
1 7
7 2
9 7
11 11
11 9
NOTES:
1. FOR CONSTRUCTION PLANS, SEE SHEET A10.1. 2. FOR REFLECTED CEILING PLANS, SEE SHEET A10.2. 3. FOR DIMENSION PLANS , SEE SHEET A10.3. 4. FOR WALL VIEWS, SEE SHEETS A10.4 - A10.6. 5. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.
DEMOLITION PLAN NOTES #
1. CAREFULLY DEMOLISH AND PROPERLY DISPOSE ALL EXISTING WALLS INDICATED BY DASHED LINES ON THE PLANS. PROTECT ADJACENT STRUCTURES, FINISHES, AND SURFACES DURING DEMOLITION ACTIVITIES TO AVOID DAMAGE.
2. PATCH AND REPAIR EXISTING DOORS AS NEEDED. PAINT ALL DOORS TO MATCH EXISTING COLOR. ENSURE ALL SURFACES ARE CLEAN, SMOOTH, AND FREE OF DEFECTS PRIOR TO PAINTING. USE COMPATIBLE MATERIALS AND FINISHES TO ACHIEVE UNIFORM APPEARANCE.
3. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING GYPSUM BOARD AND TILE AND GRID CEILINGS, INCLUDING
ELECTRICAL FIXTURES, OUTLETS, AND ALL MISCELLANEOUS CEILING COMPONENTS AS INDICATED IN THE LIGHTING PLANS. ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING STRUCTURAL OR MEP ELEMENTS TO REMAIN.
4. REPLACE OR RELOCATE ALL CEILING-MOUNTED MECHANICAL SYSTEMS WITH NEW AS SPECIFIED IN ACCORDANCE WITH MECHANICAL PLANS.
5. REMOVE AND PROPERLY DISPOSE ALL EXISTING RESTROOM PARTITIONS, DOORS, HARDWARE, AND MISCELLANEOUS ITEMS.
6. DEMOLISH AND PROPERLY DISPOSE RESTROOM FLOORING TILE, MORTAR LAYERS DOWN TO THE EXISTING SLAB SURFACE. PATCH, REPAIR AND PREPARE SURFACE TO ENSURE A LEVEL SUBSTRATE FOR NEW TILE INSTALLATION, PER CONSTRUCTION PLAN AND FINISH SCHEDULE.
7. REMOVE AND PROPERLY DISPOSE ALL PLUMBING SYSTEM, PIPING AND PLUMBING FIXTURES, PER PLUMBING PLANS. ENSURE SHUT-OFF VALVES ARE CLOSED AND TAGGED BEFORE DISCONNECTION. VERIFY PROPER SEALING OF DISCONNECTED PIPES TO AVOID LEAKS.
8. REMOVE AND PROPERLY DISPOSE ALL EXISTING TOILETS AND RESTROOM MISCELLANEOUS. CAP OFF ALL UTILITY CONNECTIONS AS REQUIRED, ENSURING SAFETY FOR SUBSEQUENT WORK.
9. REMOVE ALL EXISTING LIGHTING FIXTURES, WIRING, AND CONTROLS AS SPECIFIED IN ELECTRICAL PLANS.
VERIFY AND TAG DISCONNECTED CIRCUITS TO ENSURE ELECTRICAL SAFETY DURING WORK.
10. DEMOLISH AND REMOVE ALL THE EXISTING TILES ON ALL WALL SURFACES. PATH, REPAIR AND PREPARE TO RECEIVE A NEW TILES PER FINISH SCHEDULE.
11. CAREFULLY DETACH AND PROPERLY DISPOSE ANY MIRRORS, FIXTURES, OR OTHER OBJECTS ATTACHED TO THE WALL TO AVOID DAMAGE TO THE WALL SURFACE.
12. REMOVE AND REPLACE ALL EXISTING RESTROOM SIGNAGES WITH A NEW ONES. 2 11
9 7
6 6
11 11
Women's Restroom
Men's Restroom
RESTROOM
EXERCISE ROOM
RESTROOM
VESTIBULE
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
A10.1
- -
KEY PLAN
-2
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - CONSTRUCTION PLAN
-1
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - CONSTRUCTION PLAN
-3
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - CONSTRUCTION PLAN
FUEL ISLAND
GYM RESTROOM
ADMIN. BUILDING
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
CONSTRUCTION PLAN NOTES #
1. FURNISH AND INSTALL ALL NEW INTERIOR DRY AND WET WALLS, PER CONSTRUCTION PLAN. PATCH, REPAIR
AND PREPARE NEW AND DAMAGED SURFACES TO RECEIVE A NEW FINISH, ENSURE SEAMLESS TRANSITIONS AND HIGH-QUALITY WORKMANSHIP.
2. FURNISH AND INSTALL ALL NEW RESTROOM WALL TILES PER FINISH SCHEDULE AND CONSTRUCTION WALL VIEWS. ENSURE PROPER ALIGNMENT AND ADHERENCE TO SPECIFIED STANDARDS.
3. FURNISH AND INSTALL NEW FLOORING TILE AND FLOOR DRAINAGE, PER CONSTRUCTION PLAN AND FINISH SCHEDULE. ENSURE THE SUBSTRATE IS LEVEL AND PREPARED FOR THE TILE INSTALLATION.
4. FURNISH AND INSTALL ALL PLUMBING SYSTEM AND PIPING, PER PLUMBING PLANS. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, STANDARDS, AND PROJECT SPECIFICATIONS. COORDINATE WITH OTHER
TRADES AND DISCIPLINES TO AVOID CONFLICTS AND PROVIDE A FULLY FUNCTIONAL PLUMBING SYSTEM READY FOR TESTING AND COMMISSIONING.
5. FURNISH AND INSTALL ALL PLUMBING FIXTURES, PER FIXTURE SCHEDULE AND CONSTRUCTION PLANS.
CONDUCT THOROUGH TESTING TO ENSURE FUNCTIONALITY AND COMPLIANCE WITH LOCAL CODES.
6. FURNISH AND INSTALL ALL NEW TOILETS, RESTROOM MISCELLANEOUS AND MIRRORS PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. CONFIRM ALL INSTALLATIONS COMPLY WITH ADA ACCESSIBILITY STANDARDS, LOCAL BUILDING CODES, AND MANUFACTURER GUIDELINES.
7. FURNISH AND INSTALL RESTROOM PARTITIONS, DOORS, HARDWARE, AND ALL RELATED ACCESSORIES PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. ENSURE COMPLIANCE WITH ACCESSIBILITY
STANDARDS, DURABILITY REQUIREMENTS, AND PROPER ALIGNMENT
8. REWORK ALL EXISTING DOORS AS REQUIRED TO COMPLY WITH PROJECT SPECIFICATIONS, ACCESSIBILITY STANDARDS, AND THE DOOR SCHEDULE. ADJUST, REPAIR OR MODIFY AND PAINT DOORS, FRAMES, AND HARDWARE TO ENSURE PROPER FUNCTION, FIT, AND FINISH.
9. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL PAINT FINISH. PAINT ALL RESTROOM WALLS PER FINISH SCHEDULE UNLESS NOTED OTHERWISE. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
11. FURNISH AND INSTALL LOCKERS IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS FOR “FOREMAN,” MODEL “WALLET PHONE LOCKER.” ENSURE PROPER ANCHORAGE, ALIGNMENT, AND FUNCTIONALITY UPON INSTALLATION.
12. FURNISH AND INSTALL NEW ACCESSIBLE SIGN RESTROOM PER DETAILS 1 & 3 ON SHEET A0.2 . (N) TILE FLOORING TO INTALL
CONSTRUCTION KEY NOTES #
1. (N) FLOOR DRAIN
2. (N)WALL- MOUNTED SMALL LOCKERS
3. (N) BAG HOOK
4. (N) WALL- MOUNTED BENCH
5. (N) 3'-0" WIDE, FULL HEIGHT MIRROR
6. (N) BOLT- MOUNTED BENCH
(N) FLOOR DRAIN TO INSTALL
ACCESSIBLE CLEARANCE
11 1
2 2
6 6
6 6
7 6
6 6
2 2
CONSTRUCTION PLANS | RESTROOMS
ADMIN BUILDING & FUEL ISLAND
6 2
2 2
3 3
3 7
7 7
2 2
NOTES:
1. FOR REFLECTED CEILING PLANS, SEE SHEET A10.2. 2. FOR DIMENSION PLANS , SEE SHEET A10.3. 3. FOR WALL VIEWS, SEE SHEETS A10.4 - A10.6. 4. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. 1 1
(N) BAG HOOK
6 3 3
TYP. TYP.
3 TYP. 3TYP.
4 5
2 30"x48" ACCESSIBLE CLEARANCE
60" TURNING ACCESSIBLE CLEARANCE
(N) CONCRETE EPOXY FLOORING
3 8
8 8
2 6
6 6
2 3
1 3
8 2
RESTROOM
Women's Restroom
Men's Restroom 5'-10" 1'-9 1/2"
4'-4 1/2" 4'-4 1/2"
C.H.= 10'-00" 1'-9 1/2" 2'-5" 2'-5"
C.H.= 8'-7"
C.H.= 8'-7"
1'-8" EQ EQ 1'-8" 4'-2" 4'-2"
EQ 1'-8" EQ
2'-0" 2'-5" 4'-2" 4'-2" 2'-5"
1'-11"
C.H.= 08'-00"
1'-11" 3'-10" 2'-0" 2'-0" 2'-7" 2'-7"
EXERCISE ROOM
RESTROOM
VESTIBULE
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
A10.2
- -
KEY PLAN
FUEL ISLAND
GYM RESTROOM
ADMIN. BUILDING
RCP PLANS | RESTROOMS ADMIN
BUILDING & FUEL ISLAND
CONSTRUCTION PLAN LEGEND
(N) RECESSED LED LIGHTING
(N) EXHAUST FAN
CONST. RCP PLAN NOTES #
(N) WALL TO CONSTRUCT
(N) GYPSUM BOARD CEILING
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL GYPSUM BOARD CEILING SYSTEM IN ACCORDANCE WITH CONSTRUCTION PLAN,
ENSURE ALL CEILING HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
C.H.= # - # CEILING HEIGHT
-2
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - RCP PLAN
-1
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - RCP. PLAN
-3
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - RCP PLAN
(E) WALL TO REMAIN
AREA OF WORK
Women's Restroom
Men's Restroom
RESTROOM 5'-7" 3'-2" 9'-2"
7'-8" 4'-6" 4'-0"
5'-0" 4'-0" 3'-4" 4" 5'-6" 9'-2"
7'-8" 5"
1'-6"
Min 12"
3'-0"
Max. 6" Max. 12" 3'-6"
2'-0" 8'-1" 5'-0" 5'-0" 5'-0" 3'-0" 5'-0" 5'-0" 3'-0" 8'-1" 3'-0" 11'-9" 11'-3"
5'-7 1/2" 3'-0" 3'-0" 6'-2" 2'-0" 5'-1" 14'-0" 5" 13'-2" 5" 2'-10" 2'-0" 3" 2'-0" 9'-9"
3'-4" 3'-4" 7'-8 1/2" 3'-4" 4'-3 1/2"
22'-9" 5'-0"
11'-3" 8"
8 1/2"
5" 11'-9" 8'-1" 5" 5" 8'-11" 5'-1" 4'-8" 5"
4"
2'-5 1/2"
1'-0" 1'-6" 1'-6"
1'-6" 1'-6" 3'-0" Max. 6"
Max. 12"
3'-6"
Max. 12"
3'-6"
2'-0" 8'-7"
4'-6"
4'-0" 4'-0" 5'-0"
3'-4"
7'-9"
4" 4'-1"
7'-9" 8'-7"
9" 3'-4" 4'-6" 3'-0"
Min. 12" 1'-6"
3'-6"
Max. 12" Max. 6" 3'-0"
3'-3 1/2"
EXERCISE ROOM
RESTROOM
VESTIBULE
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
A10.3
- -
KEY PLAN
FUEL ISLAND
GYM RESTROOM
ADMIN. BUILDING
DIMENSION PLANS | RESTROOMS ADMIN
BUILDING & FUEL ISLAND
DIMENSION GENERAL NOTES
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED
ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
CONSTRUCTION PLAN LEGEND
-2
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - DIMENSION PLAN
-1
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - DIMENSION PLAN
-3
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - DIMENSION PLAN
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
(N) TILE FLOORING TO INTALL
(N) FLOOR DRAIN TO INSTALL
ACCESSIBLE CLEARANCE
(N) BAG HOOK
30"x48" ACCESSIBLE CLEARANCE
(N) CONCRETE EPOXY FLOORING
60" TURNING ACCESSIBLE CLEARANCE
B 8'-0" 17"-19" 17" MIN. MAX. 36"
1'-6" 1'-3"
3'-0"
Max. 6" 33"-36"
C 8'-0" 17" MIN. MAX. 36" 48" MAX. 66" MAX.
7"
D 8'-0" 2'-5" MAX. 8" MIN. 3'-0" 3'-4" MAX. 2'-10" MAX.
A2'-10" MAX. 2'-5" MIN. 3'-4" MAX. 8'-0" 17"-19"
7" 33"-36"
3'-6"
Max. 12"
EXERCISE ROOM
RESTROOM
VESTIBULE
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM
KEY PLAN
-2
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - WALL VIEW "B"
-3
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - WALL VIEW "C"
A10.4
- - WALL VIEWS | RESTROOMS ADMIN
BUILDING & FUEL ISLAND
NORTH
GYM RESTROOM
A
D B
C
-5
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - WALL VIEW "D"
-4
Scale: 1/2" = 1'-0"
ADMIN BUILDING @ GYM RESTROOM - WALL VIEW "A"
INTERIOR ELEVATION NOTES
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. (N) CONCRETE EPOXY FLOORING - TO INSTALL
(N) DOMINANT WALL TILE - TO INSTALL
(N) ACCENT WALL TILE - TO INSTALL
LM1
LS1
LM2
LS2
WC1
WC2
UR
WT
HD
GB
DR
SDR
WR
BH
SN
PT
FCS
TSW
OP
TD
SH
RD
SC
LS
CS
LB
LK
MR
MRC
CF
WPT
CPT
PCT
DWT
AWT
WALL-MOUNTED MULTIPLE LAVATORY
WALL-MOUNTED SINGLE LAVATORY
WALL-MOUNTED MULTIPLE LAVATORY
WALL-MOUNTED SINGLE LAVATORY
AUTOMATIC FLUSH WATER CLOSET
WALL- MOUNTED AUTOMATIC FLUSH WATER CLOSET
UNIVERSAL URINAL
COUNTER TOP WASTE CHUTE
HAND DRIER
GRAB BAR
FLOOR DRAIN
LINEAR SHOWER DRAIN FLOORING
WASTE RECEPTACLE AND PAPER TOWEL DISPENSER
BAG HOOK
SANITARY NAPKIN
PAPER TOWEL DISPENSER
COORDINATED FAUCET AND SOAP DISPENSER
TISSUE/SEAT COVER DISPENSER/ WASTE DISPOSAL
OVERHEAD BRACED RESTROOM PARTITION
TOILET TISSUE DISPENSER
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
L-SHAPED FOLDING SHOWER SEAT
COMPACT FOLDING SHOWER SEAT
LOCKER ROOM BENCH
LOCKERS
MIRROR
CUSTOM MIRROR
CONCRETE EPOXY FLOORING
WALL PAINT
CEILING PAINT
PORCELAIN FLOORING TILE
DOMINANT WALL TILE
ACCENT WALL TILE
#
UR
GB
CF
BH
FCS
WC2
TSW
GB
WT
MR
LS2
HD
TD
SN
DR
SN
UR
GB
WC2
TSW
DWT
WPT
BH
SN
TD
UR
MR
LS2
WPT
HD
WPT
AWT
GB
MR
FCS
LS2
TSW
WC2
Women's Restroom
Men's Restroom 2'-10" MAX. 2'-5" MIN. 3'-0" 3'-4" MAX. 8'-7" 17"-19"33"-36" 7"
3'-6"
Max.12" 3'-0" 2'-10" MAX. 2'-5" MIN. 3'-4" MAX. 17"-19" 1'-6" 2'-10" MAX. 2'-5" MIN. 3'-0" 3'-4" MAX. 8'-7" 48" MAX. 8'-7" 6'-10" 1'-9" 17"-19" 3'-0"
MAX. 6"
1'-6" 5'-6" 1'-6" 1'-0" 3'-0" 1'-7" 7'-0" 8'-7" 17"-19" 6'-8" 2" 1'-9" 17"-19" 17" MIN.MAX. 36" 3'-0"
MAX. 6" 8'-7" 2'-10" MAX. 2'-5" MIN. 3'-0" 3'-4" MAX. 17"-19" 3'-6"
MAX. 12" 33"- 36" 1'-7" 8'-7" 2'-10" MAX. 2'-5" MIN. 3'-0" 3'-4" MAX.
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
NORTH
KEY PLAN
ADMIN. BUILDING
-1
Scale: 3/8" = 1'-0"
ADMIN. BUILING @ RESTROOM PLAN
-4
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "C"
-7
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "F"
A10.5
- -
-2
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "A"
-8
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "G"
-3
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "B"
-9
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "H"
-5
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "D"
-6
Scale: 1/2" = 1'-0"
ADMIN. BUILING @ RESTROOM - WALL VIEW "E"
D B
C
E
H F
G
WALL VIEWS | RESTROOMS ADMIN
BUILDING & FUEL ISLAND
INTERIOR ELEVATION NOTES
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. (N) CONCRETE EPOXY FLOORING - TO INSTALL
(N) DOMINANT WALL TILE - TO INSTALL
(N) ACCENT WALL TILE - TO INSTALL
LM1
LS1
LM2
LS2
WC1
WC2
UR
WT
HD
GB
DR
SDR
WR
BH
SN
PT
FCS
TSW
OP
TD
SH
RD
SC
LS
CS
LB
LK
MR
MRC
CF
WPT
CPT
PCT
DWT
AWT
WALL-MOUNTED MULTIPLE LAVATORY
WALL-MOUNTED SINGLE LAVATORY
WALL-MOUNTED MULTIPLE LAVATORY
WALL-MOUNTED SINGLE LAVATORY
AUTOMATIC FLUSH WATER CLOSET
WALL- MOUNTED AUTOMATIC FLUSH WATER CLOSET
UNIVERSAL URINAL
COUNTER TOP WASTE CHUTE
HAND DRIER
GRAB BAR
FLOOR DRAIN
LINEAR SHOWER DRAIN FLOORING
WASTE RECEPTACLE AND PAPER TOWEL DISPENSER
BAG HOOK
SANITARY NAPKIN
PAPER TOWEL DISPENSER
COORDINATED FAUCET AND SOAP DISPENSER
TISSUE/SEAT COVER DISPENSER/ WASTE DISPOSAL
OVERHEAD BRACED RESTROOM PARTITION
TOILET TISSUE DISPENSER
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
L-SHAPED FOLDING SHOWER SEAT
COMPACT FOLDING SHOWER SEAT
LOCKER ROOM BENCH
LOCKERS
MIRROR
CUSTOM MIRROR
CONCRETE EPOXY FLOORING
WALL PAINT
CEILING PAINT
PORCELAIN FLOORING TILE
DOMINANT WALL TILE
ACCENT WALL TILE
#
MR
HD
LM2
FCS
WT
FCS
MR
MR
WT
LM2
FCS
OP
BH BH OP OP
OP
DR
WC2
BH BH
WC2
OP
GB GB
WC2 WC2
PT
PT
A
GB GB
MR
MR
TSW TSW WT HD HD
FCS
LM2
UR
UR
TD
DR
TSW TSW
HD
WT
FCS
LM2
MRC
DWT
MR
HD
WC2
TSW
LM2
MR MR MR
AWT AWT
FCS
FCS
OP
OP
DWT
DWT
LM2 LM2 LM2
HD
GB
DWT
MR
LM2
FCS
HD
TSW
WC2
AWT
OP
OP
DWT
DWT
GB
WC2
OP
DWT
WC2
TSW
LK1
LB
MRC
LB
MRC
OP
DWT
DWT
DWT
AWT
MR MR
HD
LM2 LM2
FCS FCS
GB
TSW
WC2
DWT
MR
HD
LM2
FCS
GB
TSW
WC2
UR
OP
OP
SN
DWT
BH
LB LB LOCKER BENCH
LK1 WALLET LOCKERS
LB
LK1
A10'-0" 17" MIN. 17"-19" MAX. 36" 33"-36"
3'-6"
MAX. 12" 2'-10" MAX. 2'-5" MIN. 3'-4" MAX. 10'-0" 17"-19"48" MAX. 66" MAX. 3'-0"
MAX. 6" 3'-0" 10'-0"
8" MIN. 3'-4" MAX. 2'-10" MAX. 2'-5" MAX. 10'-0" 17" MIN. MAX. 36"
RESTROOM
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
iArch
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
-1
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - CONSTRUCTION PLAN
-4
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - WALL VIEW "A"
-2
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - WALL VIEW "B"
-5
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - WALL VIEW "D"
-3
Scale: 1/2" = 1'-0"
FUEL ISLAND @ RESTROOM - WALL VIEW "C"
NORTH
KEY PLAN
FUEL ISLAND
A10.6
- - WALL VIEWS | RESTROOMS ADMIN
BUILDING & FUEL ISLAND
INTERIOR ELEVATION NOTES
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. (N) CONCRETE EPOXY FLOORING - TO INSTALL
(N) DOMINANT WALL TILE - TO INSTALL
(N) ACCENT WALL TILE - TO INSTALL
LM1
LS1
LM2
LS2
WC1
WC2
UR
WT
HD
GB
DR
SDR
WR
BH
SN
PT
FCS
TSW
OP
TD
SH
RD
SC
LS
CS
LB
LK
MR
MRC
CF
WPT
CPT
PCT
DWT
AWT
WALL-MOUNTED MULTIPLE LAVATORY
WALL-MOUNTED SINGLE LAVATORY
WALL-MOUNTED MULTIPLE LAVATORY
WALL-MOUNTED SINGLE LAVATORY
AUTOMATIC FLUSH WATER CLOSET
WALL- MOUNTED AUTOMATIC FLUSH WATER CLOSET
UNIVERSAL URINAL
COUNTER TOP WASTE CHUTE
HAND DRIER
GRAB BAR
FLOOR DRAIN
LINEAR SHOWER DRAIN FLOORING
WASTE RECEPTACLE AND PAPER TOWEL DISPENSER
BAG HOOK
SANITARY NAPKIN
PAPER TOWEL DISPENSER
COORDINATED FAUCET AND SOAP DISPENSER
TISSUE/SEAT COVER DISPENSER/ WASTE DISPOSAL
OVERHEAD BRACED RESTROOM PARTITION
TOILET TISSUE DISPENSER
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
L-SHAPED FOLDING SHOWER SEAT
COMPACT FOLDING SHOWER SEAT
LOCKER ROOM BENCH
LOCKERS
MIRROR
CUSTOM MIRROR
CONCRETE EPOXY FLOORING
WALL PAINT
CEILING PAINT
PORCELAIN FLOORING TILE
DOMINANT WALL TILE
ACCENT WALL TILE
#
DWT DWT DWT
DWT
SN TD
UR
GB
TSW
WC1
UR
SN
AWT
GB
TSW LS1
FCS
WC1
LS1
FCS
HD
MR
MR
BH
BH
A
B D
C
UR
SN
TD
GB TSW
DR GB
BH
MR
LS1
WT
FCS
HD
WC1
TRAINING ROOM
TOILET
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
A11.0
- -
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -3
Scale: 1/2" = 1'-0"
MAIN B. @ WOMEN'S RESTROOM - DEMO. PLAN
-2
Scale: 1/2" = 1'-0"
MAIN BUILDING @ MEN'S RESTROOM - DEMO. PLAN
-1
Scale: 1/2" = 1'-0"
2ND FLOOR RESTROOM-DEMO. PLAN
KEY PLAN
DEMOLITION PLANS | MAINTENANCE BUILDING
FIRST FLOOR
SECOND FLOOR
DEMOLITION PLAN NOTES #
1. CAREFULLY DEMOLISH AND PROPERLY DISPOSE ALL EXISTING WALLS INDICATED BY DASHED LINES ON THE PLANS. PROTECT ADJACENT STRUCTURES, FINISHES, AND SURFACES DURING DEMOLITION ACTIVITIES TO AVOID DAMAGE.
2. CAREFULLY REMOVE ALL EXISTING DOORS, INCLUDING FRAMES AND HARDWARE. INSPECT SURROUNDING
WALL SURFACES FOR DAMAGE AND PATCH AS REQUIRED TO PREPARE FOR NEW INSTALLATIONS IN ACCORDANCE WITH THE DOOR SCHEDULE AND ACCESSIBILITY CLEARANCE REQUIREMENTS. IF FEASIBLE
AND UNDAMAGED DURING DEMOLITION, STORE REMOVED DOORS AND HARDWARE IN A SECURE LOCATION FOR POTENTIAL REUSE OR MODIFICATION.
3. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING GYPSUM BOARD CEILINGS, INCLUDING ELECTRICAL FIXTURES, OUTLETS, AND ALL MISCELLANEOUS CEILING COMPONENTS AS INDICATED IN THE LIGHTING PLANS. ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING STRUCTURAL OR MEP ELEMENTS TO REMAIN.
4. REMOVE AND PROPERLY DISPOSE ALL EXISTING RESTROOM PARTITIONS, DOORS, HARDWARE, AND MISCELLANEOUS ITEMS.
5. DEMOLISH AND PROPERLY DISPOSE RESTROOM FLOORING TILE, MORTAR LAYERS DOWN TO THE EXISTING SLAB SURFACE. PATCH, REPAIR AND PREPARE SURFACE TO ENSURE A LEVEL SUBSTRATE FOR NEW TILE INSTALLATION, PER CONSTRUCTION PLAN AND FINISH SCHEDULE.
6. REMOVE AND PROPERLY DISPOSE ALL PLUMBING SYSTEM, PIPING AND PLUMBING FIXTURES, PER PLUMBING PLANS. ENSURE SHUT-OFF VALVES ARE CLOSED AND TAGGED BEFORE DISCONNECTION. VERIFY PROPER SEALING OF DISCONNECTED PIPES TO AVOID LEAKS.
7. REMOVE AND PROPERLY DISPOSE ALL EXISTING TOILETS AND RESTROOM MISCELLANEOUS. CAP OFF ALL UTILITY CONNECTIONS AS REQUIRED, ENSURING SAFETY FOR SUBSEQUENT WORK.
8. REMOVE ALL EXISTING LIGHTING FIXTURES, WIRING, AND CONTROLS AS SPECIFIED IN ELECTRICAL PLANS.
VERIFY AND TAG DISCONNECTED CIRCUITS TO ENSURE ELECTRICAL SAFETY DURING WORK.
9. DEMOLISH AND REMOVE ALL THE EXISTING TILES ON ALL WALL SURFACES. PATH, REPAIR AND PREPARE TO RECEIVE A NEW TILES PER FINISH SCHEDULE.
10. REMOVE AND LEGALLY DISPOSE OF ALL EXISTING BUILT-IN LOCKERS IN THEIR ENTIRETY. ENSURE THAT ALL WORK IS PERFORMED WITHOUT DAMAGE TO ADJACENT SURFACES OR STRUCTURES.
11. CAREFULLY DETACH AND PROPERLY DISPOSE ANY MIRRORS, FIXTURES, OR OTHER OBJECTS ATTACHED TO THE WALL TO AVOID DAMAGE TO THE WALL SURFACE.
12. REMOVE AND REPLACE ALL EXISTING RESTROOM SIGNAGES WITH A NEW ONES.
DEMOLITION PLAN LEGEND
(E) WALLS TO DEMOLISH
(E) WALLS TO REMAIN
SCOPE OF WORK
(E) TILE FLOORING TO REMOVE
(E) ITEMS TO DEMOLISH
DEMOLITION KEY NOTES #
1. (E) LOCKER TO - REMOVE
2. (E) DROP CEILING - TO REMOVE
3. (E) SHOWER ROOM
1 1
1 1
1 1
9 1
1 4
2 2
4 2
4 4
4 4
4 7
7 7
7 7
7 7
7 7
7 5
5 4
4 5
5 4
1 1
1 1
3 3
1 1
1 1 1
1 1
9 9
9 9
9 9
9 9
9 10
10 1
VITREOUS CHINA BATHROOM SINK KATHRYN K
2297
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
TRAINING ROOM
TOILET
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -3
Scale: 1/2" = 1'-0"
MAIN BLD.@WOMEN'S RESTROOM- CONST. PLAN
-2
Scale: 1/2" = 1'-0"
MAIN BUILDING @ MEN'S RESTROOM - CONSTRUCTION PLAN
CONSTRUCTION PLANS |
MAINTENANCE BUILDING
A11.1
- -
KEY PLAN
FIRST FLOOR
SECOND FLOOR
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO CONSTRUCT
CONSTRUCTION PLAN NOTES #
1. FURNISH AND INSTALL ALL NEW INTERIOR DRY AND WET WALLS INCLUDING THE CASED OPENING PER CONSTRUCTION PLAN. PATCH, REPAIR AND PREPARE NEW AND DAMAGED SURFACES TO RECEIVE A NEW FINISH, ENSURE SEAMLESS TRANSITIONS AND HIGH-QUALITY WORKMANSHIP.
2. FURNISH AND INSTALL ALL NEW RESTROOM WALL TILES PER FINISH SCHEDULE AND CONSTRUCTION WALL VIEWS. ENSURE PROPER ALIGNMENT AND ADHERENCE TO SPECIFIED STANDARDS.
3. FURNISH AND INSTALL NEW FLOORING TILE AND FLOOR DRAINAGE, PER CONSTRUCTION PLAN AND FINISH SCHEDULE. ENSURE THE SUBSTRATE IS LEVEL AND PREPARED FOR THE TILE INSTALLATION.
4. FURNISH AND INSTALL ALL PLUMBING SYSTEM AND PIPING, PER PLUMBING PLANS. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, STANDARDS, AND PROJECT SPECIFICATIONS. COORDINATE WITH OTHER
TRADES AND DISCIPLINES TO AVOID CONFLICTS AND PROVIDE A FULLY FUNCTIONAL PLUMBING SYSTEM READY FOR TESTING AND COMMISSIONING.
5. FURNISH AND INSTALL ALL PLUMBING FIXTURES, PER FIXTURE SCHEDULE AND CONSTRUCTION PLANS.
CONDUCT THOROUGH TESTING TO ENSURE FUNCTIONALITY AND COMPLIANCE WITH LOCAL CODES.
6. FURNISH AND INSTALL ALL EXISTING TOILETS, RESTROOM MISCELLANEOUS AND MIRRORS PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. CONFIRM ALL INSTALLATIONS COMPLY WITH ADA ACCESSIBILITY STANDARDS, LOCAL BUILDING CODES, AND MANUFACTURER GUIDELINES.
7. FURNISH AND INSTALL RESTROOM PARTITIONS, DOORS, HARDWARE, AND ALL RELATED ACCESSORIES PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. ENSURE COMPLIANCE WITH ACCESSIBILITY
STANDARDS, DURABILITY REQUIREMENTS, AND PROPER ALIGNMENT
8. FURNISH AND INSTALL ALL LIGHTING FIXTURES, WIRING, AND CONTROLS PER RCP AND ELECTRICAL PLANS. ENSURE PROPER OPERATION AND ADHERENCE TO SAFETY CODES.
9. REWORK ALL EXISTING DOORS AS REQUIRED TO COMPLY WITH PROJECT SPECIFICATIONS, ACCESSIBILITY STANDARDS, AND THE DOOR SCHEDULE. ADJUST, REPAIR, OR MODIFY DOORS, FRAMES, AND HARDWARE TO ENSURE PROPER FUNCTION, FIT, AND FINISH.
10. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL PAINT FINISH. PAINT ALL RESTROOM WALLS PER FINISH SCHEDULE UNLESS NOTED OTHERWISE. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
11. FURNISH AND INSTALL LOCKERS WITH INTEGRATED DRAWER AND BENCH IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS FOR “FOREMAN,” MODEL “SIGNATURE LOCKERS WITH AND WITHOUT SEAT.” ENSURE PROPER ANCHORAGE, ALIGNMENT, AND FUNCTIONALITY UPON INSTALLATION.
12. FURNISH AND INSTALL NEW ACCESSIBLE SIGN RESTROOM PER DETAILS 1 & 3 ON SHEET A0.2 .
13. FURNISH AND INSTALL NEW RESTROOM DOORS IN ACCORDANCE WITH THE DOOR SCHEDULE AND ARCHITECTURAL DRAWINGS. ENSURE ALL INSTALLATIONS MEET SPECIFIED DIMENSIONS, HARDWARE REQUIREMENTS, AND ADA COMPLIANCE.
(N) CONCRETE EPOXY FLOORING
CONSTRUCTION KEY NOTES #
1. (N) FLOOR DRAIN - TO INSTALL
2. (N) LINEAR SHOWER DRAIN - TO INSTALL
3. (N) LOCKER ROOM'S BENCH - TO INSTALL
4. (N) 3'-0" WIDE, FULL HEIGHT MIRROR - TO INSTALL
(N) FLOOR DRAIN TO INSTALL
ACCESSIBLE CLEARANCE
(N) BAG HOOK
30"x48" ACCESSIBLE CLEARANCE
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR REFLECTED CEILING PLANS, SEE SHEET A11.2. 2. FOR DIMENSION PLANS , SEE SHEET A11.3. 3. FOR WALL VIEWS, SEE SHEETS A11.4 - A11.6. 4. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. (N) LOCKER TO INSTALL (N) ACCESSIBLE LOCKER TO INSTALL
-1
Scale: 1/2" = 1'-0"
2ND FLOOR RESTROOM - CONTS. PLAN
1 1
1 3
1 1
2 2
1 3
3 4
4 1
1 1
1 1 1
1 1
2 2
2 2
2 2
2 2
2 2
3 3
3 3
3 3
3 6
6 6
6 6
1 1
6 6
6 7
7 7
7 1
9 1
9 2
1 11
11 11
11 3
11 3
3 3
1 1
1 6
6 6
6 6
6 2
1 1
2 2
(N) DOOR SCHEDULE
13 13
C.H.= 8'-7" 2'-6" 2'-8" 1'-6"
1'-11" 3'-10" 3'-10" 1'-11"
3'-10" 7'-8"
1'-7" 3'-4" 3'-4" 1'-7" 3'-6" 3'-6" 2'-6"
5'-9" 5'-2" 5'-2" 3'-9" 2'-0"
1'-5" 4'-4" 1'-5" 1'-10" 4'-2" 4'-2" 2'-1" 2'-1" 2'-1"
EQ EQ
1'-5" 4'-4"
3'-7"
3'-10 1/2"
C.H.= 8'-7"
1'-7" 3'-8" 2'-6"
3'-8" 1'-7" 1'-1 1/2" 4'-2 1/2"
2'-9" 3'-0 1/2" 3'-0 1/2" 1'-8"
3'-10" 2'-1"
3'-10" 2'-1" 2'-2" 2'-2" 4'-4" 2'-0" 2'-11" 2'-2" 2'-2" C.H.= 8'-7"
C.H.= 8'-7" 1'-6" 2'-2 1/2" 2'-2 1/2" 1'-6"
2'-4 1/2" 2'-4 1/2" 1'-6" 1'-9 1/2" 1'-9 1/2" 1'-6" 2'-0" 2'-0" 1'-11" 1'-11" 3'-3 1/2" 1'-11"
TRAINING ROOM
TOILET
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT -3
Scale: 1/2" = 1'-0"
MAIN BULD. @ WOMEN'S RESTROOM - RCP PLAN
-2
Scale: 1/2" = 1'-0"
MAIN BUILDING @ MEN'S RESTROOM - RCP PLAN
-1
Scale: 1/2" = 1'-0"
2ND FLOOR RESTROOM - RCP PLAN
RCP PLANS | MAINTENANCE BUILDING A11.2
- -
KEY PLAN
FIRST FLOOR
SECOND FLOOR
CONSTRUCTION PLAN LEGEND
(N) RECESSED LED LIGHTING
(N) EXHAUST FAN
CONST. RCP PLAN NOTES #
(N) WALL TO INSTALL
(N) GYPSUM BOARD CEILING
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL GYPSUM BOARD CEILING SYSTEM IN ACCORDANCE WITH CONSTRUCTION PLAN,
ENSURE ALL CEILING HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
C.H.= # - # CEILING HEIGHT
(E) WALL TO REMAIN
AREA OF WORK
5'-0" 5'-0" 2'-6" 5'-0" 6'-4" 1'-6"
5'-2"
1'-0" 5'-4" 1'-6"
3'-0" 3'-6" 3'-0"
8'-6" 4"
4'-0"
1'-6" 5'-8"
3'-0"
4'-0"
2'-1" 5'-0"
4"
4'-6"
14'-10" 5'-4" 5'-0" 4" 11'-2"
14'-3" 5" 12'-4" 28'-10" 6'-5" 3'-4" 4" 4'-4" 1'-8" 3'-4" 4" 6'-2" 3'-6" 6" 2'-0" 6" 3'-0" 5'-6" 2'-2" 4'-4" 2'-6"5'-4" 3'-0" 1'-0" 4" 6" 2'-4" 6" 15'-1" 4'-6" 5'-0" 6'-0"
4" 5'-0" 3'-1" 1'-6"
10'-6"
4'-6" 2'-10"
1'-6" 7'-0" 2'-0"
1'-6" 4'-5" 5'-0" 5'-3" 3'-0" 3'-3"
10'-6" 28'-0" 18'-6" 4" 5'-0"
6'-7" 2'-5" 1'-6" 10'-6" 6'-10"
4'-3" 3'-0" 4"
2'-11" 1'-9" 3'-10" 1'-6" 4" 4" 5'-0"
3'-1" 2'-11"
6 1/2" 3'-4" 2'-0 1/2" 3'-11"
VITREOUS CHINA BATHROOM SINK KATHRYN K2297
VITREOUS CHINA BATHROOM SINK KATHRYN K2297
3'-4" 7'-5"5'-4"
9'-0" 7'-10" 4'-0" 11'-11"
4" 3'-9"
4'-0" 4'-11"
9" 3'-4"
TRAINING ROOM
TOILET
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT DIMENSION PLANS | MAINTENANCE BUILDING A11.3
- -
-2
Scale: 1/2" = 1'-0"
MEN'S RESTROOM
-1
Scale: 1/2" = 1'-0"
2ND FLOOR RESTROOM
DIMENSION GENERAL NOTES
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY.
IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED
ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
KEY PLAN
FIRST FLOOR
SECOND FLOOR
8'-7"
WB3
M1 L
TB-02 TB-02 TB-01 TB-02
P
B1
F P
WPT 17"-19"
TB-02 17"-19" MAX
G1
W2
C
P
M2
A
A
B1
G2
TB-02
W2
W2
G2
G3 C
G2
P
T
WB3
FC
P
H
P
P
N1
F
H H
P
H H
DR DR
DR
2 F
H
A
M2
B1
B1
O
G1 8'-7"
10'-6"
W2
TB-02 TB-02 TB-02 17"-19"
P
F 8'-7" 2'-10" MAX. 2'-5" MIN. 3'-0" 3'-4" MAX.
5'-2"
11"
4'-5"
10'-6"
M1 P
L
WB3
WPT TB-02
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
TRAINING ROOM
TOILET
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT WALL VIEWS | MAINTENANCE BUILDING A11.4
- -
-2
Scale: 1/2" = 1'-0"
WOMEN'S RESTROOM - VIEW "A"
-1
Scale: 3/8" = 1'-0"
WOMEN'S RESTROOM
-4
Scale: 1/30" = 1'-0"
WOMEN'S RESTROOM - VIEW "C"
-3
Scale: 1/2" = 1'-0"
WOMEN'S RESTROOM - VIEW "B"
-5
Scale: 1/2" = 1'-0"
WOMEN'S RESTROOM - VIEW "D"
KEY PLAN
FIRST FLOOR
SECOND FLOOR
A
D B
C
INTERIOR ELEVATION NOTES #
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.
AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.
AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.
WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.
FLOOR DRAIN, SEE PLUMBING SHEET.
BENCH
MIRROR, SEE SPECIFICATION.
COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.
NAPKIN DISPENSER
SOUP DISPENSER & COORDINATED FAUCET
SANITARY NAPKIN
PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.
WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.
GRAB BARS, SEE SPECIFICATION SHEET
BAG HOOK
PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
SHOWER SEAT
LOCKER
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.
G1
TB-02
W2
G
C 17"-19" MAX
F F
TB-02
F 17"-19" MAX
TB-02 TB-01
N2
T
W2
U
WB3
WB3
FC
P
P
P
G2
G
G1
G3
H
W2
FC
C
H
H
DR DR DR
DR
D
H
F F F
H
H
H
H
M2
N
A B1
B1
L
L
L
G2 8'-7"
U
TB-02 TB-01
G2
W2
C
M1
P P
WB4 WB4 17" MIN.
L 17"-19"
WPT
G3 MAX. 36" 8'-7"
B 17"-19" MAX
L
N1 B1 17"-19" MAX
WPT
F
C 8'-7"
WB3
TB-02
D
M1
8" MIN. 3'-0" 3'-4" MAX. 2'-10" MAX. 2'-5" MAX.
L 17"-19"
B1
WPT
TRAINING ROOM
TOILET
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT A11.5
- -
-2
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "A"
-1
Scale: 1/2" = 1'-0"
MEN'S RESTROOM
-4
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "B"
-3
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "C"
-5
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "D"
KEY PLAN
FIRST FLOOR
SECOND FLOOR
A
D B
C
WALL VIEWS | MAINTENANCE BUILDING
INTERIOR ELEVATION NOTES #
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.
AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.
AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.
WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.
FLOOR DRAIN, SEE PLUMBING SHEET.
BENCH
MIRROR, SEE SPECIFICATION.
COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.
NAPKIN DISPENSER
SOUP DISPENSER & COORDINATED FAUCET
SANITARY NAPKIN
PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.
WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.
GRAB BARS, SEE SPECIFICATION SHEET
BAG HOOK
PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
SHOWER SEAT
LOCKER
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.
2'-10" MAX. 3'-0" 3'-4" MAX.
W
M1
C
W2
C
D 8'-7"
TB-01 TB-02
WB3
WB3
VITREOUS CHINA BATHROOM SINK KATHRYN
K2297
KATHRYN K2297 VITREOUS CHINA BATHROOM SINK W2
H
C
FC WB3
P
D
A
M1 C
W2
D
DR
DR
A
FC 8'-7"
A
MODELNUMBER TRADENAME PRODUCT MATERIAL 3'-0" 3'-4" MAX. 2'-10" MAX.
WB3
M1
P
TB-02 8'-7"
MODELNUMBER TRADENAME PRODUCT MATERIAL
TB-02
D
WB3
M1 3'-0" 3'-4" MAX. 2'-10" MAX. W2
C
H
D 8'-7"
P
A WB3
M1 3'-0" 3'-4" MAX. 2'-10" MAX.
TB-01 TB-02
TRAINING ROOM
TOILET
LOCKER
SHOWER
LOCKER
SHOWER
storage refrigrator micro wave coffee
STAIRS
BREAK ROOM
MEN'S LOCKERS MEN'S TOILET
WOMEN'S TOILET
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT A11.6
- -
-2
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "A"
-1
Scale: 1/2" = 1'-0"
MEN'S RESTROOM
-4
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "B"
-3
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "C"
-5
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - VIEW "D"
KEY PLAN
FIRST FLOOR
SECOND FLOOR
A
D B
C
WALL VIEWS | MAINTENANCE BUILDING
INTERIOR ELEVATION NOTES #
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.
AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.
AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.
WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.
FLOOR DRAIN, SEE PLUMBING SHEET.
BENCH
MIRROR, SEE SPECIFICATION.
COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.
NAPKIN DISPENSER
SOUP DISPENSER & COORDINATED FAUCET
SANITARY NAPKIN
PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.
WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.
GRAB BARS, SEE SPECIFICATION SHEET
BAG HOOK
PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
SHOWER SEAT
LOCKER
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.
Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
NORTH
KEY PLAN
A12.0
- -
DEMOLITION PLAN LEGEND
-2
Scale: 1/2" = 1'-0"
BUIDLING 311 @WOMEN'S RESTROOM - DEMOLITION PLAN
-1
Scale: 1/2" = 1'-0"
BUIDLING 311 @MEN'S RESTROOM - DEMOLITION PLAN
-4
Scale: 1/2" = 1'-0"
BUILDING 311@UNISEX RESTROOM 2 - DEMOLITION PLAN
-3
Scale: 1/2" = 1'-0"
BUIDING 311@UNISEX RESTROOM 1 - DEMOLITION PLAN
(E) WALLS TO REMAIN
SCOPE OF WORK
(E) TILE FLOORING TO REMOVE
(E) ITEMS TO DEMOLISH
DEMOLITION PLANS | RESTROOMS
BUILDING 311
DEMOLITION KEY NOTES #
1. (E) LOCKER - TO REMOVE
2. (E) WINDOW ABOVE - TO REMAIN
(E) WALLS TO DEMOLISH
(E) SHOWER
1 2
3 3
4 4
3 6
6 6
8 8
8 1
1 1
2 2
3 3
3 3
4 4
6 6
6 6
3 6
3 9
9 9
8 8
8 8
8 8
1 1
1 4
1 1
1 2
3 3
3 3
3 4
6 6
8 8
8 8
8 9
1 2 2
6 6 6
1 2
2 3
4 4
6 6
8 8 8
8 NOTES:
1. FOR CONSTRUCTION PLANS, SEE SHEET A12.1. 2. FOR REFLECTED CEILING PLANS, SEE SHEET A12.2. 3. FOR DIMENSION PLANS , SEE SHEET A12.3. 4. FOR WALL VIEWS, SEE SHEETS A12.4 - A12.6. 5. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0.
DEMOLITION PLAN NOTES #
1. CAREFULLY DEMOLISH AND PROPERLY DISPOSE ALL EXISTING WALLS INDICATED BY DASHED LINES ON THE PLANS. PROTECT ADJACENT STRUCTURES, FINISHES, AND SURFACES DURING DEMOLITION ACTIVITIES TO AVOID DAMAGE.
2. PATCH AND REPAIR EXISTING DOORS AS NEEDED. PAINT ALL DOORS TO MATCH EXISTING COLOR. ENSURE ALL SURFACES ARE CLEAN, SMOOTH, AND FREE OF DEFECTS PRIOR TO PAINTING. USE COMPATIBLE MATERIALS AND FINISHES TO ACHIEVE UNIFORM APPEARANCE.
3. REMOVE AND PROPERLY DISPOSE OF ALL EXISTING GYPSUM BOARD AND TILE AND GRID CEILINGS, INCLUDING
ELECTRICAL FIXTURES, OUTLETS, AND ALL MISCELLANEOUS CEILING COMPONENTS AS INDICATED IN THE LIGHTING PLANS. ENSURE REMOVAL IS PERFORMED WITHOUT DAMAGING STRUCTURAL OR MEP ELEMENTS TO REMAIN.
4. REPLACE OR RELOCATE ALL CEILING-MOUNTED MECHANICAL SYSTEMS WITH NEW AS SPECIFIED IN ACCORDANCE WITH MECHANICAL PLANS.
5. REMOVE AND PROPERLY DISPOSE ALL EXISTING RESTROOM PARTITIONS, DOORS, HARDWARE, AND MISCELLANEOUS ITEMS.
6. DEMOLISH AND PROPERLY DISPOSE RESTROOM FLOORING TILE, MORTAR LAYERS DOWN TO THE EXISTING SLAB SURFACE. PATCH, REPAIR AND PREPARE SURFACE TO ENSURE A LEVEL SUBSTRATE FOR NEW TILE INSTALLATION, PER CONSTRUCTION PLAN AND FINISH SCHEDULE.
7. REMOVE AND PROPERLY DISPOSE ALL PLUMBING SYSTEM, PIPING AND PLUMBING FIXTURES, PER PLUMBING PLANS. ENSURE SHUT-OFF VALVES ARE CLOSED AND TAGGED BEFORE DISCONNECTION. VERIFY PROPER SEALING OF DISCONNECTED PIPES TO AVOID LEAKS.
8. REMOVE AND PROPERLY DISPOSE ALL EXISTING TOILETS AND RESTROOM MISCELLANEOUS. CAP OFF ALL UTILITY CONNECTIONS AS REQUIRED, ENSURING SAFETY FOR SUBSEQUENT WORK.
9. REMOVE ALL EXISTING LIGHTING FIXTURES, WIRING, AND CONTROLS AS SPECIFIED IN ELECTRICAL PLANS.
VERIFY AND TAG DISCONNECTED CIRCUITS TO ENSURE ELECTRICAL SAFETY DURING WORK.
10. DEMOLISH AND REMOVE ALL THE EXISTING TILES ON ALL WALL SURFACES. PATH, REPAIR AND PREPARE TO RECEIVE A NEW TILES PER FINISH SCHEDULE.
11. CAREFULLY DETACH AND PROPERLY DISPOSE ANY MIRRORS, FIXTURES, OR OTHER OBJECTS ATTACHED TO THE WALL TO AVOID DAMAGE TO THE WALL SURFACE.
12. REMOVE AND REPLACE ALL EXISTING RESTROOM SIGNAGES WITH A NEW ONES.
Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CONSTRUCTION PLAN LEGEND
-2
Scale: 1/2" = 1'-0"
BUIDLING 311 @ WOMEN'S RESTROOM - CONSTRUCTION PLAN
-1
Scale: 1/2" = 1'-0"
BUIDLING 311 @ MEN'S RESTROOM - CONSTRUCTION PLAN
-4
Scale: 1/2" = 1'-0"
BUILDING 311 @ UNISEX RESTROOM 2 - CONSTRUCTION PLAN
-3
Scale: 1/2" = 1'-0"
BUIDING 311 @ UNISEX RESTROOM 1 - CONSTRUCTION PLAN
NORTH
KEY PLAN
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO CONSTRUCT
CONSTRUCTION PLAN NOTES #
1. FURNISH AND INSTALL ALL NEW INTERIOR DRY AND WET WALLS INCLUDING THE CASED OPENING PER CONSTRUCTION PLAN. PATCH, REPAIR AND PREPARE NEW AND DAMAGED SURFACES TO RECEIVE A NEW FINISH, ENSURE SEAMLESS TRANSITIONS AND HIGH-QUALITY WORKMANSHIP.
2. FURNISH AND INSTALL ALL NEW RESTROOM WALL TILES PER FINISH SCHEDULE AND CONSTRUCTION WALL VIEWS. ENSURE PROPER ALIGNMENT AND ADHERENCE TO SPECIFIED STANDARDS.
3. FURNISH AND INSTALL NEW FLOORING TILE AND FLOOR DRAINAGE, PER CONSTRUCTION PLAN AND FINISH SCHEDULE. ENSURE THE SUBSTRATE IS LEVEL AND PREPARED FOR THE TILE INSTALLATION.
4. FURNISH AND INSTALL ALL PLUMBING SYSTEM AND PIPING, PER PLUMBING PLANS. ENSURE COMPLIANCE WITH ALL APPLICABLE CODES, STANDARDS, AND PROJECT SPECIFICATIONS. COORDINATE WITH OTHER
TRADES AND DISCIPLINES TO AVOID CONFLICTS AND PROVIDE A FULLY FUNCTIONAL PLUMBING SYSTEM READY FOR TESTING AND COMMISSIONING.
5. FURNISH AND INSTALL ALL PLUMBING FIXTURES, PER FIXTURE SCHEDULE AND CONSTRUCTION PLANS.
CONDUCT THOROUGH TESTING TO ENSURE FUNCTIONALITY AND COMPLIANCE WITH LOCAL CODES.
6. FURNISH AND INSTALL ALL EXISTING TOILETS, RESTROOM MISCELLANEOUS AND MIRRORS PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. CONFIRM ALL INSTALLATIONS COMPLY WITH ADA ACCESSIBILITY STANDARDS, LOCAL BUILDING CODES, AND MANUFACTURER GUIDELINES.
7. FURNISH AND INSTALL RESTROOM PARTITIONS, DOORS, HARDWARE, AND ALL RELATED ACCESSORIES PER EQUIPMENT SCHEDULE AND MANUFACTURE SPECIFICATION. ENSURE COMPLIANCE WITH ACCESSIBILITY
STANDARDS, DURABILITY REQUIREMENTS, AND PROPER ALIGNMENT
8. FURNISH AND INSTALL ALL LIGHTING FIXTURES, WIRING, AND CONTROLS PER RCP AND ELECTRICAL PLANS. ENSURE PROPER OPERATION AND ADHERENCE TO SAFETY CODES.
9. REWORK ALL EXISTING DOORS AS REQUIRED TO COMPLY WITH PROJECT SPECIFICATIONS, ACCESSIBILITY STANDARDS, AND THE DOOR SCHEDULE. ADJUST, REPAIR, OR MODIFY DOORS, FRAMES, AND HARDWARE TO ENSURE PROPER FUNCTION, FIT, AND FINISH.
10. REPAIR ALL LOOSE AND FLAKING PAINT FROM INTERIOR AND EXTERIOR WALLS. PATCH, SAND, AND PREPARE SURFACES FOR A NEW WALL PAINT FINISH. PAINT ALL RESTROOM WALLS PER FINISH SCHEDULE UNLESS NOTED OTHERWISE. ENSURE ALL EXISTING AND NEW WALLS ARE PROPERLY PAINTED AS REQUIRED.
11. FURNISH AND INSTALL LOCKERS WITH INTEGRATED DRAWER AND BENCH IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS FOR “FOREMAN,” MODEL “SIGNATURE LOCKER WITH AND WITHOUT SEAT.” ENSURE PROPER ANCHORAGE, ALIGNMENT, AND FUNCTIONALITY UPON INSTALLATION.
12. FURNISH AND INSTALL NEW ACCESSIBLE SIGN RESTROOM PER DETAILS 1 & 3 ON SHEET A0.2 . (N) CONCRETE EPOXY FLOORING
CONSTRUCTION KEY NOTES #
1. (N) FLOOR DRAIN - TO INSTALL
2. (N) LINEAR SHOWER DRAIN - TO INSTALL
3. (N) LOCKER ROOM'S BENCH - TO INSTALL
4. (E) WINDOW ABOVE - TO REMAIN
5. (N) 3'-0" WIDE, FULL HEIGHT MIRROR - TO INSTALL
3 (N) FLOOR DRAIN TO INSTALL
2 2
2 2
6 6
9 ACCESSIBLE CLEARANCE
1 A12.1
- - CONSTRUCTION PLANS |
RESTROOMS BUILDING 311
1 2
2 2
2 3
3 6
6 6
6 9
2 7
7 7
9 10
10 10
10 11
11 11
11 1
1 1
2 1
3 2
1 1
6 2 6
2 3
9 1
2 6
6 2
6 3
1 1
1 3 2
2 6
6 7
7 7
6 6
6 9
10 10
10 11
1 1
4 4
7 2 2 2
1 (N) BAG HOOK
30"x48" ACCESSIBLE CLEARANCE
60" TURNING ACCESSIBLE CLEARANCE
5 5
NOTES:
1. FOR REFLECTED CEILING PLANS, SEE SHEET A12.2. 2. FOR DIMENSION PLANS , SEE SHEET A12.3. 3. FOR WALL VIEWS, SEE SHEETS A12.4 - A12.6. 4. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. (N) LOCKER TO INSTALL
(N) ACCESSIBLE LOCKER TO INSTALL
2'-0"
C.H.= 8'-00" EQ EQ
2'-0" 4'-6" 4'-6"
C.H.= 07'-11"
C.H.= 09'-1"
1'-3" 3'-11" 3'-11" 1'-3"
2'-0" 2'-1"
EQ 2'-2" 2'-2" 3'-1" 3'-1" 1'-4"
5'-5" 5'-5" 4'-2"
EQ EQ
5'-5" 5'-5" 4'-2" 4'-2" 4'-2" 4'-2" 4'-2"
4'-2"
EQ 4'-2"
1'-10" 2'-4"
C.H.= 8'-11"
2'-4" 5'-8" 3'-9" 4'-4" 2'-6" 4'-5" 4'-5" 2'-0" 2'-1"
1'-6" 2'-0" 1'-6" 1'-6" 1'-6" 3'-2" 2'-1" 1'-2" Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC 8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 C.H.= 8'-00" 2'-0" 5'-5" 2'-0"
1'-11" 5'-0" 1'-11"
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
CONSTRUCTION PLAN LEGEND
NORTH
KEY PLAN
(N) RECESSED LED LIGHTING
(N) EXHAUST FAN
CONST. RCP PLAN NOTES #
(N) WALL TO INSTALL
(N) GYPSUM BOARD CEILING
1. PATCH AND REPAIR ALL CEILING SUBSTRATE AS NEEDED THROUGHOUT ALL CEILING. PREPARE TO RECEIVE A NEW GYPSUM BOARD AND TILES AND GRID CEILING.
2. FURNISH AND INSTALL ALL GYPSUM BOARD CEILING SYSTEM IN ACCORDANCE WITH CONSTRUCTION PLAN,
ENSURE ALL CEILING HEIGHTS, MATERIALS, AND FINISHES ARE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS.
3. FURNISH AND INSTALL ALL WIRING, AND CONDUIT IN ACCORDANCE WITH THE ELECTRICAL AND CONSTRUCTION PLANS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS. PROPERLY DISCONNECT AND PROTECT EXISTING SYSTEMS BEFORE RELOCATION.
4. FURNISH AND INSTALL ALL LIGHTING FIXTURES, HVAC DIFFUSERS AND OTHER CEILING ELEMENTS, PER ELECTRICAL AND MECHANICAL DRAWINGS. ENSURE ALL ELECTRICAL WORK COMPLIES WITH LOCAL CODES AND SAFETY REGULATIONS.
C.H.= # - # CEILING HEIGHT
A12.2
- - RCP PLANS | RESTROOMS BUILDING 311
-2
Scale: 1/2" = 1'-0"
BUIDLING 311 @WOMEN'S RESTROOM - RCP. PLAN
-1
Scale: 1/2" = 1'-0"
BUIDLING 311 @MEN'S RESTROOM - RCP. PLAN
-4
Scale: 1/2" = 1'-0"
BUILDING 311@UNISEX RESTROOM 2 - RCP. PLAN
-3
Scale: 1/2" = 1'-0"
BUIDING 311@UNISEX RESTROOM 1 - RCP. PLAN
6'-8"
13'-0"
4'-6" 5'-0"
6'-2" 3'-4" 1'-6" 2'-0" 5" 6'-8" 5" 7'-6"
5" 13'-0" 5"
13'-10" 2'-8"
2'-6" 5'-0"
5'-3"
4'-1" 5'-6"
4'-1" 4" 4"
2'-0" 8'-3"
3'-0" 7'-3" 8'-4" 3'-5" 2'-0"
3'-0"
8" 3'-4" 3'-4" 8" 1'-0"
1'-6" 3'-9" 1'-8" 3'-7" 5'-0"
5'-0" 1'-6"
10'-3" 5" 5'-6" 1'-5" 6'-4" 3'-4" 5" 17'-5"
5"
1'-6"
5" 16'-9" 1'-0" 1'-6"
7'-3" 4'-4" 3'-4"
4" 3'-4" 10" 3'-0" 4'-3" 6'-0" 5" 16'-7" 5" 17'-5"
4'-1" 4" 4'-1" 4" 2'-6" 9" 3'-4" 16'-0"
31'-10"
15'-3" 5'-8" 3'-4" 11'-11"
8'-2"
3'-0" 4'-0" 5'-0"
4'-6"
5'-0" 4'-6" 5'-10"
5"
5'-0" 3'-3"3'-0"
5'-0"
10" 2'-6" 4'-0"
4'-6" 5'-0" 2'-6"3'-2" 6'-4"
4'-7" 3'-10"
3'-7"
4" 4"
6'-3" 3'-4" 9'-0" 12'-11"
6" 2'-0" 6"
3'-0" 3'-3" 9'-8"
4" 6" 2'-0" 2'-6" 4"
9'-11" 1'-8" 3'-0" 1'-8"
18'-7"
Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 5'-5" 2'-6"3'-0"
4'-6" 5'-0"
5'-1" 3'-4" 4"
8'-9" 9'-5"
5"
4'-0" 5'-0"
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
NORTH
KEY PLAN
DIMENSION PLANS | RESTROOMS A12.3
BUILDING 311
-2
Scale: 1/2" = 1'-0"
BUIDLING 311 @WOMEN'S RESTROOM - DIMENSION PLAN
-1
Scale: 1/2" = 1'-0"
BUIDLING 311 @MEN'S RESTROOM - DIMENSION PLAN
-4
Scale: 1/2" = 1'-0"
BUILDING 311@UNISEX RESTROOM 2 - DIMESION PLAN
-3
Scale: 1/2" = 1'-0"
BUIDING 311@UNISEX RESTROOM 1 - DIMENSION PLAN
DIMENSION GENERAL NOTES
1. DIMENSIONS TO BE VERIFIED ON SITE – ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO FABRICATION OR CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
2. REFERENCE TO STRUCTURAL & MEP DRAWINGS – COORDINATE ALL DIMENSIONS WITH STRUCTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS. REPORT ANY CONFLICTS BEFORE PROCEEDING WITH WORK.
3. DIMENSIONS FROM FIXED POINTS – ALL DIMENSIONS ARE TAKEN FROM FINISHED SURFACES, FACE OF STUDS, OR COLUMN GRID LINES UNLESS OTHERWISE NOTED.
4. NO SCALING ALLOWED – DO NOT SCALE DRAWINGS FOR DIMENSIONS. USE FIGURED DIMENSIONS ONLY. IF A DIMENSION IS MISSING OR UNCLEAR, REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER.
5. LEVELS & HEIGHTS – ELEVATIONS AND FINISHED FLOOR HEIGHTS SHALL BE TAKEN FROM BENCHMARKS ESTABLISHED ON SITE. VERIFY EXISTING CONDITIONS BEFORE SETTING ANY NEW WORK.
6. CLEARANCES & TOLERANCES – ENSURE ALL REQUIRED CLEARANCES AND TOLERANCES FOR
CONSTRUCTION MATERIALS, SYSTEMS, AND EQUIPMENT INSTALLATION ARE MAINTAINED AS PER MANUFACTURER’S REQUIREMENTS AND CODE COMPLIANCE.
7. OPENINGS & PENETRATIONS – COORDINATE LOCATIONS OF ALL OPENINGS FOR DOORS, WINDOWS, DUCTS, AND CONDUITS. VERIFY AND ALIGN WITH ARCHITECTURAL, STRUCTURAL, AND MEP DRAWINGS.
8. FIRE-RATED ASSEMBLIES – WHERE WALLS, FLOORS, OR CEILINGS ARE PART OF A FIRE-RATED
ASSEMBLY, DIMENSIONS SHALL ACCOUNT FOR REQUIRED FIRE-RATED MATERIALS AND CONSTRUCTION TECHNIQUES.
9. ADA & CODE COMPLIANCE – ALL DIMENSIONS AND CLEARANCES SHALL COMPLY WITH APPLICABLE BUILDING CODES AND ADA (AMERICANS WITH DISABILITIES ACT) REQUIREMENTS WHERE APPLICABLE.
10. GRID LINE COORDINATION – ALL DIMENSIONS SHALL BE TAKEN FROM COLUMN GRID LINES OR CONTROL POINTS SHOWN ON THE DRAWINGS. ANY DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL, AND CIVIL DRAWINGS SHALL BE REPORTED IMMEDIATELY.
11. ENSURE ACCURACY – ALL CONTRACTORS SHALL ENSURE DIMENSIONS ARE CONSISTENT WITH SHOP DRAWINGS, EQUIPMENT REQUIREMENTS, AND SITE CONDITIONS.
12. FINAL RESPONSIBILITY – CONTRACTOR SHALL TAKE FINAL RESPONSIBILITY FOR ACCURATE FIELD MEASUREMENTS AND COORDINATION OF ALL TRADES TO ENSURE A PROPER FIT AND FUNCTION.
CONSTRUCTION PLAN LEGEND
(N) WALL TO CONSTRUCT
(E) WALL TO REMAIN
(N) BAG HOOK
30"x48" ACCESSIBLE CLEARANCE
DOOR ACCESSIBLE CLEARANCE
60" TURNING ACCESSIBLE CLEARANCE
P
P
WB3
T
FC
W
W
G
G
G
C
H
C
P
2 M
H
H
D
H
H
A
DR
DR
DR
H
H
M B
L1
L1
L2
N1
F
M
L2
L1
U Lobby 1 10 21 OFFICE Copy RM Electrical RM EEOC
8 9 Office Admin 22 Kitchenette 13 16 Boiler RM 19 Sink STORE RM Phone and Electrical 15 Hall C Lunch Room 5 4
3 Paint Booth 14 20 Closet EEOC EEOC
12 Hall Area B
2 Manager of St. Div Administrative Staff Area Office Streets Supervisor General Staff Office Conference Room Room Body Shop 1st Floor Storage 6 Hall Area A Conference RM Sink
Unisex
Unisex
Restroom 1
Restroom 2
7 11
Women's Restroom
18 Men's Restroom
17 7'-11" 1'-7"
U
W
C 17" MIN.
F
TB-02 TB-02
TB-02
TD MAX. 36" 7'-11" 17"-19" MAX
TB-01 M
G
N1
TB-02 TB-02
TB-02
F
FC
A 17"-19" MAX 7'-11"
W
G
C
N1
TB-02 17"-19"
C7'-11"
G
W
U
TB-02 MAX. 36"
TD
SN
UNDER THE SUPERVISION OF: Sheet Number:
DESIGNED BY:
DRAWN BY:
CHECKED BY: DATE: Department of Public Works
ATTENTION IS DIRECTED TO THE POSSIBLE EXISTENCE OF UNDERGROUND FACILITIES NOT
SHOWN OR IN A LOCATION DIFFERENT FROM WHAT IS SHOWN ON THE PLANS OR IN THE SPECIAL PROVISIONS. THE CONTRACTOR SHALL TAKE STEPS TO ASCERTAIN THE EXACT
LOCATION OF ALL UNDERGROUND FACILITIES PRIOR TO START OF WORK THAT MAY DAMAGE SUCH FACILITIES OR INTERFERE WITH THEIR SERVICES. BEFORE EXCAVATION, THE CONTRACTOR SHALL VERIFY THE LOCATION OF UNDERGROUND UTILITIES BY CONTACTING UNDERGROUND UTILITIES SERVICE ALERT AT 1 (800) 422-4133.
UNDERGROUND SERVICE ALERT OF SOUTHERN CALIFORNIA
Mehran Golestan
iArch
Steve Forster
P.N.: 2.1000.03
NO. DATE BY DESCRIPTION APPROV.
REVISIONS CITY OF MONTEBELLO
311 S Greenwood Ave. , Montebello , CA 90640
TRANSPORTATION FACILITY REMODEL
INTERIOR ELEVATION NOTES #
NORTH
KEY PLAN
-4
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - ELEVATION VIEW "A"
-2
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - ELEVATION VIEW "B"
-5
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - ELEVATION VIEW "D"
-3
Scale: 1/2" = 1'-0"
MEN'S RESTROOM - ELEVATION VIEW "C"
A
D B
C
WALL VIEWS | RESTROOMS A12.4
BUILDING 311
P
W
U
WB
DR
B
M
C
A
FC
SN
PT
D
A
G
H
A
B
F
RD
SC
N
L
RESTROOM STALLS & DOORS, SEE SPECIFICATION SHEET.
AUTOMATIC FLUSH WATER CLOSET , SEE PLUMBING SHEET.
AUTOMATIC FLUSH URINAL, SEE PLUMBING SHEET.
WALL-MOUNTED LAVATORY, SEE SPECIFICATION AND PLUMBING SHEET.
FLOOR DRAIN, SEE PLUMBING SHEET.
BENCH
MIRROR, SEE SPECIFICATION.
COVER SEAT DISPENSER, SEE SPECIFICATION SHEET.
NAPKIN DISPENSER
SOUP DISPENSER & COORDINATED FAUCET
SANITARY NAPKIN
PAPER TOWER DISPENSER
HAND DRYER,SEE SPECIFICATION SHEET.
WASTE RECEPTACLE, ,SEE SPECIFICATION SHEET.
GRAB BARS, SEE SPECIFICATION SHEET
BAG HOOK
PAPER TOWEL DISPENSER AND WASTE WALL MOUNTED
BENCH
SHOWER HEAD
SHOWER ROD
SHOWER CURTAIN
SHOWER SEAT
LOCKER
CONSTRUCTION PLAN LEGEND
(E) WALL TO REMAIN
AREA OF WORK
(N) WALL TO INSTALL
(N) TILE FLOORING TO INTALL
30"x48" ACCESSIBLE CLEARANCE
(N) FLOOR DRAIN TO INSTALL
DOOR ACCESSIBLE CLEARANCE
(N) BAG HOOK
# EQUIPMENT ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
# FINISH ID - SEE EQUIPMENT SCHEDULE ON SHEET XXX.
60" TURNING ACCESSIBLE CLEARANCE
NOTES:
1. FOR FINISH AND EQUIPMENT SCHEDULES, SEE SHEETS A13.0. -1
Scale: 1/2" = 1'-0"
BUIDLING 311 @MEN'S RESTROOM - CONSTRUCTION PLAN